6W / 15W Bollard
L97
SPEC SHEET Application: Outdoor / Indoor walkway and area illumination. Electrical: 6 x 1W LEDs or 6 x 2.5W LEDs powered by remote 24V driver (not included). Input Current: 350mA (6W) / 700mA (15W) Input Voltage: 24V DC Power Consumption: 6W / 15W Recommended Driver: TLDAV100W24V. Dimmable with 100W 24V LED driver and controller, 0~10V dimming (not included). Consult factory.
8-1/2” 216mm
Weight: 9.59lbs (4.35kg) based on 36” (914mm) post.
1-5/8” 5-3/8” x 6-3/8” 41mm 137mm x 162mm
Material: Anodized aluminum. 1/4” (6mm) thick polycarbonate lens and silicone gaskets. Mounting: Mounts to 36” (914mm) or 48” (1219mm) anodized aluminum post. Comes with 24” (610mm) Cabtire lead inside post. Approval: Wet and dry locations. Approved to US and Canadian standards by CSA.
Post Height
67 Note: An appropriate 24V DC LED driver must be used with fixture. Can be used as emergency backup lighting in conjunction with Bodine emergency LED driver (sold separately). Consult factory.
Type: Project:
1/4” 6mm
4-1/2” 114mm
Modified: Quantity:
6” Sq. 152mm Sq.
Notes:
8-1/2” 216mm
Code L97
Wattage
6-3/8” 162mm
Color
Beam
-
post height (h)
Finish
1 = 6 x 1W 2 = 6 x 2.5W*
Post Height
W27S W30S W35S W41S W30H
= 2700K, std CRI = 3000K, 5-3/8” std CRI 137mm = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI
12 = 12° beam 1-5/8” 30 = 30° beam 41mm 60 = 60° beam
36 = 36” (914mm) 48 = 48” (1219mm)
MA = matte clear anodized BA = black anodized
*Only available in W30S (3000K, std CRI)
1/4” 6mm
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada 4-1/2” 114mm
Copyright 6” © MP Lighting. All technical information in this document is subject to change.
152mm
02-2011
6W / 15W Bollard
L97
SPEC SHEET Photometric Data
L97 6 x 1W, 12° 3000K Std 510 lm
Polar Candela Distribution 180° -90°
Height Conversion Formula
Isofootcandle Plot 1
2
90°
0
1
Step 1 1
New Mounting Height²
0 -45°
approx. 3200 cd max.
45°
-0° -90°
L97 6 x 1W, 30° 3000K Std 510 lm
Step 2
20 2.5 0.5 0.2
1 2
0.1 fc
Mount height: 3 ft Total LLF: 1
0°
Polar Candela Distribution
= Correction Factor (CF)
CF x Footcandle = New Mounting Height FC
Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.
Isofootcandle Plot
180° -90°
Existing Mounting Height²
1
2
90°
0
1
1 0 -45°
approx. 1300 cd max.
45°
-0° -90°
2
0.1 fc
Mount height: 3 ft Total LLF: 1
0°
L97 6 x 1W, 60° 3000K Std 510 lm
20 2.5 0.5 0.2
1
Polar Candela Distribution
Isofootcandle Plot
180° -90°
1
2
90°
0
1
1 0 -45°
approx. 450 cd max.
45°
-0° -90°
2
0.1 fc
Mount height: 3 ft Total LLF: 1
0°
L97 6 x 2.5W, 12° 3000K Std 972 lm
20 5 0.5 0.2
1
Polar Candela Distribution
Isofootcandle Plot
180°
2
-90°
90°
1
0
1
2
3
2 1 0
-45°
approx. 6000 cd max.
45°
0°
1
-0°
2
-90°
3
20 2.5 0.5 0.2 0.1 fc Mount height: 3 ft Total LLF: 1
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
12-2010
6W / 15W Bollard
L97
SPEC SHEET Photometric Data
L97 6 x 2.5W, 30° 3000K Std 972 lm
Polar Candela Distribution 180°
2
-90°
Height Conversion Formula
Isofootcandle Plot
90°
1
0
1
2
3
Step 1
2
New Mounting Height²
1 0 -45°
approx. 2400 cd max.
45°
2
-90°
3
Step 2 0.1 fc
Mount height: 3 ft Total LLF: 1
0°
L97 6 x 2.5W, 60° 3000K Std 972 lm
20 2.5 1.0 0.2
1
-0°
Polar Candela Distribution
= Correction Factor (CF)
CF x Footcandle = New Mounting Height FC
Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.
Isofootcandle Plot
180°
2
-90°
Existing Mounting Height²
90°
1
0
1
2
3
2 1 0
-45°
approx. 850 cd max.
45°
0°
1
-0°
2
-90°
3
20 5 1.0 0.2
0.1 fc
Mount height: 3 ft Total LLF: 1
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011