/L98_spec

Page 1

6W / 15W Wall Sconce

L98

SPEC SHEET Application: Wall mounted for up or down outdoor/indoor illumination. Electrical: 6 x 1W LEDs or 6 x 2.5W LEDs powered by remote 24V driver (not included). Input Current: 350mA (6W) / 700mA (15W) Input Voltage: 24V DC Power Consumption: 6W / 15W Recommended Driver: TLDAV100W24. Dimmable with 100W 24V driver and controller, 0~10V dimming (not included). Weight: 2.24lbs (1.54kg). Material: Anodized aluminum or 316 stainless steel. 1/4” (6mm) thick polycarbonate lens, and silicone gaskets. Mounting: Mounts to standard outdoor rated octagonal back box (not included) via universal round mounting bracket, comes with standard 6’ (1829 mm). Cabtire water proof lead (longer leads available).

6” 152mm

3-1/4” 83mm

Approval: Wet and dry locations. Approved to US and Canadian standards by CSA.

5-3/8” 137mm

67 NOTE: An appropriate 24V DC LED driver must be used with fixture. Can be used as emergency backup lighting in conjunction with Bodine emergency LED driver (sold separately). Consult factory.

5-3/4” 146mm

4-3/8” 111mm

1/8” 3mm

1-5/8” 41mm

Type: Project: Modified: Quantity: Notes:

Code L98

Wattage

Color

Beam

-

Lead Length

Finish

1 = 6 x 1W 2 = 6 x 2.5W*

W27S W30S W35S W41S W30H

= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI

12 = 12° beam 30 = 30° beam 60 = 60° beam

6 = 6' (1829mm) lead X = custom length

MA = matte clear anodized BA = black anodized S6 = stainless steel 316

*Only available in W30S (3000K, std CRI)

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

02-2011


6W / 15W Wall Sconce

L98

SPEC SHEET Photometric Data

L98 6 x 1W, 12° 3000K Std 510 lm

Polar Candela Distribution 180°

1

-90°

1

2

Step 1 20 0.5

1 -45°

approx. 2700 cd max.

45°

-0°

New Mounting Height²

5 0.1 fc

Step 2

-90° Mount height: 9 ft Total LLF: 1

Polar Candela Distribution

= Correction Factor (CF)

CF x Footcandle = New Mounting Height FC

Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.

Isofootcandle Plot

180°

1

-90°

Existing Mounting Height²

2

0

1

2

90° 0

20 1 0.2 0.1 fc

1 -45°

approx. 1300 cd max.

45°

-0°

2

-90° Mount height: 9 ft Total LLF: 1

L98 6 x 1W, 60° 3000K Std 510 lm

0

90° 0

L98 6 x 1W, 30° 3000K Std 510 lm

Height Conversion Formula

Isofootcandle Plot

Polar Candela Distribution

Isofootcandle Plot

180°

0

-90°

1

20

90°

2.5 0.5 1 -45°

approx. 440 cd max.

45°

-0° -90° Mount height: 9 ft Total LLF: 1

L98 6 x 2.5W, 12° 3000K Std 972 lm

0.1 fc

Polar Candela Distribution

Isofootcandle Plot

180°

1

-90°

0

1

2

90° 0 1

-45°

approx. 6000 cd max.

45°

-0°

20 1 0.2 0.1 fc

2

-90° Mount height: 9 ft Total LLF: 1

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

02-2011


6W / 15W Wall Sconce

L98

SPEC SHEET Photometric Data

L98 6 x 2.5W, 30° 3000K Std 972 lm

Polar Candela Distribution 180°

1

-90°

0

1

2

90°

Step 1

0

0.2

-45°

approx. 2400 cd max.

45°

-0°

Step 2

CF x Footcandle = New Mounting Height FC

2

Mount height: 9 ft Total LLF: 1

Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.

Isofootcandle Plot

180°

1

-90°

= Correction Factor (CF)

0.1 fc

-90°

Polar Candela Distribution

Existing Mounting Height² New Mounting Height²

20 1

1

L98 6 x 2.5W, 60° 3000K Std 972 lm

Height Conversion Formula

Isofootcandle Plot

0

1

2

90° 0 1

-45°

approx. 850 cd max.

45°

-0°

20 2.5 0.5

0.1 fc

2

-90° Mount height: 9 ft Total LLF: 1

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

02-2011


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.