2 x 6W/15W Wall Sconce
L99
SPEC SHEET Application: Wall mounted for up or down outdoor/indoor illumination. Electrical: 12 x 1W LEDs or 12 x 2.5W powered by remote 700mA driver (not included). Input Current: 700mA Input Voltage: 24V DC Power Consumption: 12W / 30W Recommended Driver: TLDAV100W24. Dimmable with 100W 24V LED driver and controller, 0~10V dimming (not included). Weight: 5.64lbs (2.56kg). Material: Anodized aluminum or 316 stainless steel. 1/4” (6mm) thick polycarbonate lens, and silicone gaskets. Mounting: Mounts to standard outdoor rated octagonal back box (not included) via universal round mounting bracket, comes with standard 6’ (1829 mm). Cabtire water proof lead (longer leads available). Approval: Wet and dry locations. Approved to US and Canadian standards by CSA. 6” 152mm 4-3/8” 111mm
1/8” 3mm
3-1/4” 83mm
1-5/8” 41mm
5-3/8” 137mm
67 NOTE: An appropriate 24V DC LED driver must be used with fixture. Can be used as emergency backup lighting in conjunction with Bodine emergency LED driver (sold separately). Consult factory.
5-3/4” 146mm
Type: Project: Modified: Quantity: Notes:
Code L99
wattage
Color Up
Beam Up
Color Down
Beam Down
-
Lead Length
Finish
1 = 6 x 1W 2 = 6 x 2.5W*
W27S = 2700K, std CRI W30S = 3000K, std CRI W35S = 3500K, std CRI W41S = 4100K, std CRI W30H = 3000K, high CRI
1 = 12° 3 = 30° 6 = 60°
W27S = 2700K, std CRI W30S = 3000K, std CRI W35S = 3500K, std CRI W41S = 4100K, std CRI W30H = 3000K, high CRI
1 = 12° 3 = 30° 6 = 60°
6 = 6' (1829mm) X = custom length
MA = matte clear anodized BA = black anodized S6 = stainless steel 316
*Only available in W30S (3000K, std CRI).
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
2 x 6W/15W Wall Sconce
L99
SPEC SHEET Photometric Data
L99 12 x 1W, 12° 3000K Std 1020 lm
Polar Candela Distribution 180°
1
-90°
1
2
Step 1 20 0.5
1 -45°
approx. 3300 cd max.
45°
-0°
New Mounting Height²
5 0.1 fc
Step 2
-90° Mount height: 9 ft Total LLF: 1
Polar Candela Distribution
= Correction Factor (CF)
CF x Footcandle = New Mounting Height FC
Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.
Isofootcandle Plot
180°
1
-90°
Existing Mounting Height²
2
0°
0
1
2
90° 0
20 1 0.2 0.1 fc
1 -45°
approx. 1300 cd max.
45°
-0°
2
-90° Mount height: 9 ft Total LLF: 1
0°
L99 12 x 1W, 60° 3000K Std 1020 lm
0
90° 0
L99 12 x 1W, 30° 3000K Std 1020 lm
Height Conversion Formula
Isofootcandle Plot
Polar Candela Distribution
Isofootcandle Plot
180°
0
-90°
1
20
90°
2.5 0.5 1 -45°
approx. 450 cd max.
45°
-0° -90° Mount height: 9 ft Total LLF: 1
0°
L99 12 x 2.5W, 12° 3000K Std 1944 lm
0.1 fc
Polar Candela Distribution
Isofootcandle Plot
180°
1
-90°
0
1
2
90° 0 1
-45°
approx. 6000 cd max.
45°
0°
-0°
20 1 0.2 0.1 fc
2
-90° Mount height: 9 ft Total LLF: 1
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
2 x 6W/15W Wall Sconce
L99
SPEC SHEET Photometric Data
L99 12 x 2.5W, 30° 3000K Std 1944 lm
Polar Candela Distribution 180°
1
-90°
0
1
2
90°
Step 1
0
0.2
-45°
approx. 2400 cd max.
45°
-0°
Step 2
CF x Footcandle = New Mounting Height FC
2
Mount height: 9 ft Total LLF: 1
0°
Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.
Isofootcandle Plot
180°
1
-90°
= Correction Factor (CF)
0.1 fc
-90°
Polar Candela Distribution
Existing Mounting Height² New Mounting Height²
20 1
1
L99 12 x 2.5W, 60° 3000K Std 1944 lm
Height Conversion Formula
Isofootcandle Plot
0
1
2
90° 0 1
-45°
approx. 820 cd max.
45°
0°
-0°
20 2.5 0.5
0.1 fc
2
-90° Mount height: 9 ft Total LLF: 1
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011