MSI Diamond Knife Catalog

Page 1



Diamond cutting instruments for microsurgery

About MSI Precision At MSI Precision, we believe understanding how our customers work is just as important as understanding industry. That’s why we’ve spent the last 20 years building a company with you in mind. Like account managers who not only answer calls, but answer questions. And the brand name technology products to rival the brand name companies. Listening hard and responding with urgency has brought us 20 years of success. What can we do for you next?


Diamond cutting instruments for microsurgery

2

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

3


Diamond cutting instruments for microsurgery

Contents Diamond knives for cataract surgery (titanium handles with a pressure mechanism)

5

Diamond knives for cataract surgery (titanium bajonet handle with the j-slot mechanism)

8

Diamond knives for glaucoma surgery

11

Diamond knives for LRI surgery

12

Diamond knives with a micrometer for refractive surgery

13

Diamond knives for retinal surgery (with a titanium handle)

15

Step diamond knives

16

Diamond knives for neuro surgery

18

Zeppelin diamond knives for neuro surgery

19

Diamond knife for neuro surgery - dura knife for dura opening

21

Cosmetic diamond knives for plastic surgery

22

Black diamond knives

23

Cleaning liquid & accessories

25

Unitholder

26

Directions of use

27

Customer service

30

4

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Diamond knives for cataract surgery (titanium handles with a pressure mechanism)

The MSI Precision pencil handle is made our of best quality titanium or medical steel material. Each diamond blade goes with a straight blade holder or a 30 degree angled holder.

drawing

angled holder

straight holder description

216A 287A 212A 264SA

216 287 212 264S

215A 211A 210A 211SA

B

L

D

A/A1

blade

straight / single edge straight straight straight straight

0.7 1.0 1.0 1.5

2.0 2.0 3.0 4.0

0.17 0.17 0.17 0.17

30° 30° 30° 30°

16 87 12 64S

215 211 210 211S

straight straight straight straight

0.7 1.0 1.5 2.0

2.0 3.0 3.0 3.0

0.17 0.17 0.17 0.17

45° 45° 45° 45°

15 11 10 11S

217A 213A

217 213

tri-facet tri-facet

0.7 1.0

2.0 3.0

0.17 0.17

45°/30° 17 45°/30° 13

224A

224

curved 4 facets

1.0

3.0

0.17

24

tri-facet

curved

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

5


Diamond cutting instruments for microsurgery

drawing

angled holder

straight holder description

248A 271A 218A 220A 214SA 214A 221A

248 271 218 220 214 214 221

lance straight straight straight straight straight straight straight

230A 219A 229A 208A 243A 222A 223A 278A

230 219 229 208 243 222 223 278

spear spear with spear with spear with spear with spear with spear with spear with spear with

blunt blunt blunt blunt blunt blunt blunt blunt

sides sides sides sides sides sides sides sides

B

L

D

A/A1

blade

0.7 1.0 1.0 1.5 0.7 1.0 1.5

2.0 2.0 3.0 4.0 2.0 3.0 3.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17

30° 30° 30° 30° 45° 45° 45°

16 87 12 64S 15 11 10

1.0 1.0 1.4 2.5 2.8 3.0 3.2 3.5

2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90° 90°

30 19 29 8 43 22 23 78

1.4 2.0 2.2 2.5 3.0

tunnel 239A 254A 258A 255A 253A

239 254 258 255 253

tunnel tunnel tunnel tunnel tunnel

19 19 19 19 19

facets facets facets facets facets

4.0 4.0 4.0 4.0 4.0

0.17 0.17 0.17 0.17 0.17

new 231A 235A 236A 237A 238A 261A 262A 263A 265A

231 235 236 237 238 261 262 263 265

clear cornea MICS micro coaxial surgery clear cornea with sharp sides 1.6 4.0 clear cornea with sharp sides 1.7 4.0 clear cornea with sharp sides 1.8 4.0 clear cornea with sharp sides 1.9 4.0 clear cornea with sharp sides 2.0 4.0 clear cornea with sharp sides 2.1 4.0 clear cornea with sharp sides 2.2 4.0 clear cornea with sharp sides 2.3 4.0 clear cornea with sharp sides 2.4 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17

39 54 58 55 38

90° 90° 90° 90° 90° 90° 90° 90° 90°

B = width / L = length / D = thickness / A = angle

6

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

31 35 36 37 38 61 62 63 65


Diamond cutting instruments for microsurgery

drawing

angled holder

straight holder

297A 234A

297 234

298A 272A 295A 277A 273A 274A 293A

298 272 295 277 273 274 293

clear clear clear clear clear clear clear

new 279A 280A 282A 284-01A 284A 284-02A 284-03A

291A 290A 292A 232A 240A 233A 289A

288A 283A

description clear cornea 60° clear cornea with sharp sides clear cornea with sharp sides clear cornea 90°

B1/B

L

D

A/A1

blade

3.0 3.2

4.0 4.0

0.17 0.17

60° 60°

97 34

2.5 2.6 2.65 2.8 3.0 3.2 3.5

4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90°

98 72 95 77 73 74 93

279 280 282 284-01 284 284-02 284-03

tapered spear MICS micro coaxial surgery spear 4 facets with sharp sides 1.1-1.4 4.0 spear 4 facets with sharp sides 1.5-1.8 4.0 spear 4 facets with sharp sides 1.5-2.0 4.0 spear 4 facets with sharp sides 1.7-2.0 4.0 spear 4 facets with sharp sides 1.8-2.2 4.0 spear 4 facets with sharp sides 2.0-2.3 4.0 spear 4 facets with sharp sides 2.4-2.7 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90°

79 80 82 84-01 84 84-02 84-03

291 290 292 232 240 233 289

tapered spear 4 facets spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp

4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.10 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90°

91 90 92 32 40 33 89

288 283

tapered spear 6 facets spear 6 facets with sharp sided spear 6 facets with sharp sides

2.65-3.2 4.0 3.0-3.2 4.0

0.17 0.17

90° 90°

88 83

cornea cornea cornea cornea cornea cornea cornea

with with with with with with with

sharp sharp sharp sharp sharp sharp sharp

sides sides sides sides sides sides sides

sides sides sides sides sides sides sides

2.5-3.0 2.5-3.0 2.7-2.9 2.75-3.2 3.0-3.2 3.0-3.5 3.2-3.5

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

7


Diamond cutting instruments for microsurgery

Diamond knives for cataract surgery (titanium bajonet handle with the j-slot mechanism)

The MSI Precision bayonet handle is made out of best quality titanium or medical steel material. Each diamond blade goes with a straight blade holder or a 30 degree angled holder.

e in ailabl v a o als dle k han e e p a

drawing

angled holder

straight holder

316A 387A 312A 364SA

316 387 312 364S

315A 311A 310A 311SA

315 311 310 311S

description

B

L

D

A/A1

blade

straight / single edge straight straight straight straight

0.7 1.0 1.0 1.5

2.0 2.0 3.0 4.0

0.17 0.17 0.17 0.17

30° 30° 30° 30°

16 87 12 64

straight straight straight straight

0.7 1.0 1.5 2.0

2.0 3.0 3.0 3.0

0.17 0.17 0.17 0.17

45° 45° 45° 45°

15 11 10 11S

tri-facet tri-facet

0.7 1.0

2.0 3.0

0.17 0.17

45°/30° 17 45°/30° 13

curved curved 4 facets

1.0

3.0

0.17

24

tri-facet 317A 313A

324A

317 313

324

B = width / L = length / D = thickness / A = angle

8

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

drawing

angled holder

straight holder

318A 348A 371A 320A 314SA 314A 321A

318 248 371 320 314S 314 321

330A 319A 329A 307A 308A 343A 322A 323A 378A

330 319 329 307 308 343 322 323 378

339A 354A 358A 355A 353A

339 354 358 355 353

tunnel tunnel tunnel tunnel tunnel

new 331A 335A 336A 337A 338A 361A 362A 363A 365A

331 335 336 337 338 361 362 363 365

description lance lance with blunt sides lance with blunt sides lance with blunt sides lance with blunt sides lance with blunt sides lance with blunt sides lance with blunt sides spear spear with blunt sides spear with blunt sides spear with blunt sides spear with blunt sides spear with blunt sides spear with blunt sides spear with blunt sides spear with blunt sides spear with blunt sides

B

L

D

A/A1

blade

1.0 0.9 1.0 1.0 1.2 1.4 3.2

2.0 3.0 3.0 3.0 3.0 3.0 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17

60° 60° 40° 60° 60° 60° 60°

18 48 71 20 14S 14 21

1.0 1.0 1.4 2.2 2.5 2.8 3.0 3.2 3.5

2.0 3.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90° 90° 90°

30 19 29 07 08 43 22 23 78

1.4 2.0 2.2 2.5 3.0

4.0 4.0 4.0 4.0 4.0

0.17 0.17 0.17 0.17 0.17

clear cornea MICS micro coaxial surgery clear cornea with sharp sides 1.6 4.0 clear cornea with sharp sides 1.7 4.0 clear cornea with sharp sides 1.8 4.0 clear cornea with sharp sides 1.9 4.0 clear cornea with sharp sides 2.0 4.0 clear cornea with sharp sides 2.1 4.0 clear cornea with sharp sides 2.2 4.0 clear cornea with sharp sides 2.3 4.0 clear cornea with sharp sides 2.4 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17

tunnel 19 19 19 19 19

facets facets facets facets facets

39 54 58 55 53

90° 90° 90° 90° 90° 90° 90° 90° 90°

31 35 36 37 38 61 62 63 65

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

9


Diamond cutting instruments for microsurgery

drawing

angled holder

straight holder

397A 334A

397 334

398A 372A 395A 377A 373A 374A 393A

398 372 395 377 373 374 393

clear clear clear clear clear clear clear

new 379A 380A 382A 384-01A 384A 384-02A 384-03A

description clear cornea 60° clear cornea with sharp sides clear cornea with sharp sides spear clear cornea 90°

B1/B

L

D

A/A1

blade

3.0 3.2

4.0 4.0

0.17 0.17

60° 60°

97 34

2.5 2.6 2.65 2.8 3.0 3.2 3.5

4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90°

98 72 95 77 73 74 93

379 380 382 384-01 384 384-02 384-03

tapered spear MICS micro coaxial surgery spear 4 facets with sharp sides 1.1-1.4 4.0 spear 4 facets with sharp sides 1.5-1.8 4.0 spear 4 facets with sharp sides 1.5-2.0 4.0 spear 4 facets with sharp sides 1.7-2.0 4.0 spear 4 facets with sharp sides 1.8-2.2 4.0 spear 4 facets with sharp sides 2.0-2.3 4.0 spear 4 facets with sharp sides 2.4-2.7 4.0

0.17 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90°

79 80 82 84-01 84 84-02 84-03

391A 390A 392A 332A 340A 333A 389A

391 390 392 332 340 333 389

tapered spear 4 facets spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp spear 4 facets with sharp

sides sides sides sides sides sides sides

2.5-3.0 4.0 2.5-3.0 4.0 2.7-2.9 4.0 2.75-3.2 4.0 3.0-3.2 4.0 3.0-3.5 4.0 3.2-3.5 4.0

0.10 0.17 0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90° 90° 90°

91 90 92 32 40 33 89

388A 383A

388 383

tapered spear 6 facets spear 6 facets with sharp sided spear 6 facets with sharp sides

2.65-3.2 4.0 3.0-3.2 4.0

0.17 0.17

90° 90°

88 83

cornea cornea cornea cornea cornea cornea cornea

with with with with with with with

sharp sharp sharp sharp sharp sharp sharp

sides sides sides sides sides sides sides

B = width / L = length / D = thickness / A = angle

10

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Diamond knives for glaucoma surgery drawing

artical no. description

B

B1

L

D

A

blade

333-01

1.0

0.55

4.5

0.17

knife with straight holder 301-01

0.5

3.5

0.2

20째

01-01

3.5

0.17

25째

20-01

Zaldivar multi purpose knife 33-01

step knife 820-01

1.0

0.3

steps: 0.15, 0.2, 0.25, 0.3, 0.37, 0.5, 4.0

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

11


Diamond cutting instruments for microsurgery

Diamond knives for LRI surgery drawing

article no. description with 3 settings: 0.5, 0.55, 0.6 820-02

B

B1

L

D

A

blade

1.0

0.4

3.0

0.1

20°

20-02

with 1 setting 820-02-01 0.5 820-02-02 0.55 820-02-03 0.6

1.0 1.0 1.0

3.0 3.0 3.0

0.1 0.1 0.1

20° 20° 20°

20-02 20-02 20-02

0.4 0.4 0.4

Donnenfield LRI knife B 820-03 1 setting at 0.6 0.8 Features: • single footplate design with a fixed depth of 0.6mm • the shorter handle length promotes ease of use under the microscope or at the slit lamp • the blade assembly retracts into handle for safe storage

B1 0.25

S 0.6

D 0.17

A 20°

blade 20-03

Nichamin LRI knife 820-04 Features: • very small footplate • better visualization for the surgeon • excellent control while creating the incision

B1 0.2

S

D 0.1

A 15°

blade 20-04

B 0.8

• diamond with a micro flip • accurate for techniques utilizing pachymetry • steps: 0.45, 0.5, 0.55, 0.6, 0.65, 0.7, 0.75

B = width / L = length / D = thickness / A = angle

12

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Diamond knives with a micrometer for refractive surgery Each depth can be adjusted without steps. The scale is divided each hundredth millimeter t=blade thickness of 0.1mm.

drawing

article no. straight 511 511t

description

B

L

D

A/A1

blade

straight straight

1.0 0.9

3.0 3.0

0.17 0.1

45° 45°

11 11t

512 512t

straight straight

1.0 1.0

3.0 3.0

0.17 0.1

30° 30°

12 12t

tri-facet 513 513t

tri-facet tri-facet

1.0 1.0

3.0 3.0

0.17 0.17

45°/30° 13 45°/30° 13t

axe 525 525t

axe axe

1.5 1.5

3.0 3.0

0.17 0.1

45° 45°

1.0 1.0

3.0 3.0

0.17 0.1

triple edge vertical 526 triple edge vertical 526t triple edge vertical

25 25t

26 26t

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

13


Diamond cutting instruments for microsurgery

drawing

article no. description double edge vertical 527 double edge vertical 527t double edge vertical

B

L

D

A

blade

1.0 1.0

3.0 3.0

0.17 0.17

45° 45°

27 27t

single edge vertical 528 single edge vertical 528t single edge vertical

1.0 1.0

3.0 3.0

0.17 0.1

45° 45°

28 28t

arcuate (thornton) 533t arcuate (thronton)

1.0

3.0

0.1

15°

33t

precision trak 566

1.0

3.0

0.17

45°

66

amidia-trak

B = width / L = length / D = thickness / A = angle

14

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Diamond knives for retinal surgery (with a titanium handle)

drawing

article no. 301R 302R 311R

description retina straight retina straight straight 45째 (retina)

B 0.5 0.9 1.0

L 3.0 3.0 3.0

D 0.17 0.17 0.17

A 20째 45째 45째

blade 1 2 11

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

15


Diamond cutting instruments for microsurgery

Step diamond knives Available with all diamond blades you will find in our leaflets for seven step handle.

drawing

article no. straight 811

tri-facet 813

description

B

L

D

A/A1

blade

straight 1.0 steps at 0/0.3/0.4/0.5/0.6/0.8/1.0/2.5mm

3.0

0.17

45°

11

tri-facet 1.0 steps at 0/0.3/0.4/0.5/0.6/0.8/1.0/2.5mm

3.0

0.17

45°/30° 13

3.0

0.17

45°

27

spear with blunt sides 2.0 4.0 spear with blunt sides 3.2 4.0 steps at 0.15/0.2/0.25/0.3/0.37/0.5/4.0 mm

0.17 0.17

45° 45°

22 23

double edge vertical 827 double edge vertcal 1.0 steps at 0/0.3/0.4/0.5/0.6/0.8/1.0/2.5mm

spear 822 823

other steps available as per customers request B = width / L = length / D = thickness / A = angle

16

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

drawing

article no. straight 885 821

description

B

L

D

A

blade

lance with blunt sides lance with blunt sides

3.0 3.2

4.0 4.0

0.17 0.17

60° 60°

85 21

clear cornea 60° 898 clear cornea with sharp sides 834 clear cornea with sharp sides

3.0 3.2

4.0 4.0

0.17 0.17

60° 60°

97 34

clear cornea 90° 898 clear cornea with sharp sides 895 clear cornea with sharp sides 877 clear cornea with sharp sides 873 clear cornea with sharp sides 874 clear cornea with sharp sides

2.5 2.6 2.8 3.0 3.2

3.5 3.5 3.5 3.5 3.5

0.17 0.17 0.17 0.17 0.17

90° 90° 90° 90° 90°

98 95 77 73 74

B1 0.3

L 3.5

D 0.17

A 25°

blade 20-01

Glaucoma 820-01 steps: 0.15, 0.2, 0.25, 0.3, 0.37, 0.5, 4.0

B 1.0

other steps available as per customers request

one step handle tri-facet 309-F tri-facet, depth at 0.28 209-F tri-facet, depth at 0.3

1.0 1.0

0.17 0.17

60° 60°

9 9

one step handle straight 315-F straight, depth at 0.28 215-F straight, depth at 0.3

0.7 0.7

0.17 0.17

45° 45°

15 15

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

17


Diamond cutting instruments for microsurgery

Diamond knives for neuro surgery The MSI Precision neuro surgery handles are available with a straight or angled holder.

drawing

article no. description angled straight N250A N250 straight, single sided N267A N267 straight, single sided

B

L

D

A

blade

1.0 1.0

3.0 3.0

0.17 0.17

30° 45°

50 67

lance N268A N268 N251A N251

lance, single sided lance, single sided

1.0 1.4

4.0 3.0

0.17 0.17

60° 60°

68 51

round N269A N269A

round 7 facets single sided

1.0

3.0

0.17

special N281

triple edge vertical

1.5

1.8

0.17

69

60°

B = width / L = length / D = thickness / A = angle

18

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

81


Diamond cutting instruments for microsurgery

Zeppelin diamond knives for neuro surgery For extremly delicate micro-incisions and dissections. The cutting edges are distinguished by their superb sharpness.

drawing

article no. description

B

L

D

A

blade

PDD 011

lance diamond knife, straight sharp, slightly upward angled tip 15% working/total length 50 mm/170 mm

1.40

3.0

0.17

60°

A-51

PDD

111

lance diamond knife, straight sharp, slightly upward angled tip 15% working/total length 50 mm/170 mm

1.40

3.0

0.17

60°

A-51

PDD 112

triple edge vertical diamond knife, straight, tip blunt 90° angled working total length 100 mm/220 mm

1.40

0.17

60°

A-81

PDD 113

triple edge vertical diamond knife, straight, tip sharp 90° angled working total length 100 mm/220 mm

1.40

60°

A-81

0.17

To order please contact MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

phone fax e-mail website

800-633-7283 800-699-2839 don@msiprecision.com www.msiprecision.com

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

19


Diamond cutting instruments for microsurgery

drawing

article no. description

PDD 211

PDD 311

PDD 411

PDD 511

PDD 611

PDD 711

lance diamond knife, straight sharp, slightly upward angled tip 15% working/total length 120 mm/210 mm

lance diamond knife, straight sharp, slightly upward angled tip 15% working/total length 100 mm/220 mm lance diamond knife, straight sharp, slightly upward angled tip 15% working/total length 120 mm/240 mm lance diamond knife, straight sharp, slightly upward angled tip 15% working/total length 140 mm/260 mm

vario diamond knife bayonet, sharp, slightly upward angled tip (15°) working/total length 150 mm/270 vario diamond knife bayonet, sharp, slightly upward angled tip (15°) working/total length 120 mm/24

B

L

D

A

blade

1.40

3.0

0.17

60°

A-51

1.40

3.0

0.17

60°

A-51

1.40

3.0

0.17

60°

A-51

1.40

3.0

0.17

60°

A-51

1.40

3.0

0.17

60°

A-51

1.40

3.0

0.17

60°

A-51

To order please contact MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

phone fax e-mail website

800-633-7283 800-699-2839 don@msiprecision.com www.msiprecision.com

B = width / L = length / D = thickness / A = angle

20

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Diamond knife for neuro surgery dura knife for dura opening

• Easy and fast cutting thanks to the extremely sharp diamond blade • The precisely adjustable cutting depth allows a safe procedure • Consistent cutting capabilities even after years of use • Handle made of titanium and surface coated in high vacuum

article no. N269-01

description dura knife

B 1.4

L 4.0

D 0.2

blade 69-01

0.30

drawing

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

21


Diamond cutting instruments for microsurgery

Cosmetic diamond knives for plastic surgery Cosmetic scalpels are much sharper than steel blades and they keep their sharpness even after many procedures. This enables the surgeon to have the highest precision and the cleanest cut available. Incisions with diamond scalpels are easier to make; wounds heal better and faster.

article no. PABD1311

article no. PABD1315

22

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Black diamond knives • Better visualization • Non-glare surface • Consistent, predictable & superior diamond edge incision • Reduced acquisition cost • Reduced repair cost • Available in titanium or peek handles

drawing

angled holder

straight holder

PABD1010A PABD1010PA PABD1012A PABD1012PA

PABD1175A PABD1175PA PABD1180A PABD1180PA PABD1182A PABD1182PA PABD1183A PABD1183PA PABD1184A PABD1184PA PABD1185A PABD1185PA

B1/B

L

D

A

blade

PABD1010 PABD1010P PABD1012 PABD1012P

description lance lance lance lance lance

1.0 1.0 1.2 1.2

4.0 4.0 4.0 4.0

0.20 0.20 0.20 0.20

60° 60° 60° 60°

1010 1010 1012 1012

PABD1175 PABD1175P PABD1180 PABD1180P PABD1182 PABD1182P PABD1183 PABD1183P PABD1184 PABD1184P PABD1185 PABD1185P

trapezoid tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear tapered spear

1.5-1.8 1.5-1.8 2.5-2.8 2.5-2.8 2.65-3.0 2.65-3.0 2.8-3.0 2.8-3.0 2.7-3.2 2.7.-3.2 2.5-3.5 2.5-3.5

4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

90° 90° 90° 90° 90° 90° 90° 90° 90° 90° 90° 90°

1175 1175 1180 1180 1182 1182 1183 1183 1184 1184 1185 1185

B = width / L = length / D = thickness / A = angle Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

23


Diamond cutting instruments for microsurgery

Black diamond knives • Better visualization • Non-glare surface • Consistent, predictable & superior diamond edge incision • Reduced acquisition cost • Reduced repair cost • Available in titanium or peek handles

drawing

angled holder

straight holder

PABD1120A PABD1120PA PABD1123A PABD1123PA PABD1125A PABD1125PA

PABD1150A PABD1150PA PABD1158A PABD1158PA PABD1160A PABD1160PA PABD1162A PABD1162PA PABD1163A PABD1163PA

PABD1210A PABD1210PA

B

L

D

A

blade

PABD1120 PABD1120P PABD1123 PABD1123P PABD1125 PABD1125P

description spear 2 sides sharp spear spear spear spear spear spear

2.8 2.8 3.0 3.0 3.2 3.2

4.0 4.0 4.0 4.0 4.0 4.0

0.20 0.20 0.20 0.20 0.20 0.20

90° 90° 90° 90° 90° 90°

1120 1120 1123 1123 1125 1125

PABD1150 PABD1150P PABD1158 PABD1158P PABD1160 PABD1160P PABD1162 PABD1162P PABD1163 PABD1163P

clear cornea4 sides sharp spear vc spear vc spear vc spear vc spear vc spear vc spear vc spear vc spear vc spear vc

2.2 2.2 2.65 2.65 2.8 2.8 3.0 3.0 3.2 3.2

4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

90° 90° 90° 90° 90° 90° 90° 90° 90° 90°

1150 1150 1158 1158 1160 1160 1162 1162 1164 1164

PABD1210 PABD1210P

crescent 9-edge vertical 9-edge vertical

2.0 2.0

4.0 4.0

0.20 0.20

B = width / L = length / D = thickness / A = angle

24

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

1210 1210


Diamond cutting instruments for microsurgery

Cleaning liquid & accessories cleaner MSI Precision rapid cleaner is the recommended cleaning liquid for the diamond knives 9000

rapid cleaner

250ml

9001

rapid cleaner

500ml

9002

rapid cleaner

1000ml

cleaning sticks MSI Precision cleaning sticks to remove the particles from the blade 9014

1 set of cleaning sticks (5 pieces of styropor with razor blade)

measuring gauge 600

measuring gauge type RK

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

25


Diamond cutting instruments for microsurgery

Unitholder unitholder MSI Precision unitholders are designed to hold the instruments for easy cleaning 9010

4.6 mm / 6 pcs. of pencil, titan bayonet, one step, 3 settings step and micrometer

9011

6.5 mm / 6 pcs. of retinal, seven step

9012

4.6 mm / 1 pc. of pencil, titan bayonet, one step, 3 settings step and micrometer

9013

6.5 mm / 1 pcs. of retinal, seven step

The unitholders are designed to position the knives into a ultrasound cleaner

article no. 9010/9011

26

article no. 9012/9013

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

Directions for use Preparation (cleaning, disinfecting and sterilization) of diamond knives from MSI Preicision Specialty Instruments. General basic principles The diamond knives must be cleaned, disinfected and sterilized beforehand every time they are used; this particularly applies also to first use after delivery since the diamond knives are delivered unsterilized (cleaning and disinfecting after removal of the transport protective packaging; sterilization after packing). Effective cleaning and disinfecting is an essential prerequisite for effective sterilization. Please always observe as part of your responsibility for the sterility of the diamond knives for the application that only adequate device and product-specific validated processes for the cleaning/disinfecting and sterilization should be used, that the devices used (disinfector, steriliser) are serviced and checked regularly, and the validated parameters for each cycle are observed. Please also observe the valid legal provisions in your country as well as the hygiene regulations of the medical practice or hospital. This particularly applies for the different regulations concerning effective prion deactivation. Cutters and tips are very sensitive to mechanical touching which is why one should absolutely avoid any situation during manipulation, particularly during cleaning and during safe storage, in which the diamond knives touch each other or come into contact with other hard materials. The traditionally used sieve or the bowl for random mounting are not at all suitable as eye instruments. The ideal container must be made out of a metal-tolerant material and be subdivided in such a way that it does not touch the diamond knives and that it does impact the sensitive blades and tips.

Cleaning and disinfecting Basics An automated process (a disinfector) should be used wherever possible for cleaning and disinfecting. A manual process should only be used if an automated process is unavailable because of its significantly lower effectiveness and reproducibility1. 1

Use of a manual cleaning and disinfecting process must be secured by means of an additional product and process-specific validation, which is the responsibility of the user.

Perform pre-treatment in both cases.

Pre-ttreatment Rough dirt and fouling must be removed from the diamond knives immediately after use (within a maximum of 2 hours). Use flowing water to do this or a cleaning agent solution; the cleaning agent should be compatible with the diamond knives (see chapter “Resistance of the material to various substances“; we recommend our cleaner “Rapid Cleaner“ type No. 9000, 9001 and 9002). Clean the diamond knives and the blades using a soft, lint-free, damp cloth or by using the MSI Precision cleaning sticks Type No. 9014. Clean diamond blades with the cloth or cleaning sticks in the direction of cutting against the tip. In cases of strong fouling, we recommend hanging the diamond knives on the MSI Precision instrument stands type 9010, 9011, 9012 or 9013 and dipping the knives in MSI Precision Rapid Cleaner so as just to cover the fouling, to soften the dirt. The diamond knives should not be totally immersed since particles of dirt could get into the mechanism and negatively effect their function. You can also perform an additional disinfection to protect personnel; the disinfecting agent should be aldehyde-free (otherwise there will be fixing of blood spots), should have a checked effectiveness (e.g. a DG HM or FDA approval or CE marking), be suitable for disinfecting the diamond knives and be compatible with the diamond knives (see chapter “Resistance of the material to various substances“). Please note that this disinfection – after cleaning – can not replace the disinfection step to be performed.

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

27


Diamond cutting instruments for microsurgery

28

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Diamond cutting instruments for microsurgery

MSI Precision Speciaty Instruments 1220 Valley Forge Rd, Building 34 Phoenixville, PA 19460

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

29


Diamond cutting instruments for microsurgery

Customer service Most of our diamond blades can be resharpened several times if they are not too badly damaged.

We always do our best in order to return your repairs as soon as possible.

For each repair, the handle is totally dismantled, and all of the mechanical parts are cleaned, checked and replaced if necessary. Micrometer and step knives are recalibrated.

However, the lead time may be variable due to the many different kind of blade types we receive for resharpening.

After regrinding, the diamond blade is as good as a new blade. We accept other knives for repair except the micrometer knives. However, we can not accept reponsibility for the breakage of blades other than MSI Precision.

30

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com


Order Form B I L L T O

(Please fill out completely)

Your Address ___________________________________ ___________________________________ ___________________________________ Attention: Accounts Payable ___________________________________

Contact Name

Phone ( ____ Purchase Order Number Qty.

_____________________________ ) ___________________________

Check if Same As Bill To Address ___________________________________ ___________________________________ ___________________________________ ___________________________________

Authorization Signature

______________________________ Product Number

S H I P T O

Page No.

_________________________________

Description of Product

Internal Use Only

_______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ Method Desired For Shipment (Please Select Method) FedEx (Ground) FedEx 2Day

FedEx Priority Overnight

Send Order Request To:

Fax Your Order to:

MSI Precision Instruments

FedEx Standard Overnight

610-935-5844

1220 Valley Forge Road, Bld 34 / Phoenixville PA 19460 800-322-4674 / 800-633-7283 msi.orderform.0405


Instrument Repair Form (Please fill out completely) B I L L T O

Your Address ___________________________________ ___________________________________ ___________________________________ Attention: Accounts Payable ___________________________________

Contact Name

Phone ( ____ Purchase Order Number Qty.

_____________________________ ) ___________________________

______________________________ Product Number

S H I P T O

Check if Same As Bill To Address ___________________________________ ___________________________________ ___________________________________ ___________________________________

Repair Authorization Signature

_________________________________

Please call before repairs are started.

Description of Problem

Internal Use Only

_______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ Method Desired For Return / Shipment (Please Select Method) FedEx (Ground) FedEx 2Day

FedEx Priority Overnight

Send Repairs To:

Fax Your Order to:

MSI Precision Instruments

FedEx Standard Overnight

610-935-5844

27 Maple Avenue / Holbrook, MA 02343 If you have questions call (610) 935-8181 msi.repairform.0405


Terms of Sale

Procedure

• This price list supersedes all price lists. • All prices are F.O.B. Phoenixville, Pennsylvania, subject to change without notice • Our terms are Net 30 days to approved accounts • List prices are subject to change • All MSI Precision instruments are guaranteed to be free of defects in materials and workmanship. Any instrument which proves defective in workmanship or material will be repaired or replaced at our discretion with out charge. This guarantee is void for instruments serviced by any company other than MSI Precision instrument repair service. • All MSI Precision instruments are carefully inspected before shipment. Any claims must be made within (2) two days of receipt of shipment. Most orders are shipped same day and, at the latest, by UPS within 72 hours.

Return Policy • With our prior written authorization, returns may be made within 30 days of purchase for full credit. Instruments must be unused and in their original package. • To insure proper credit, you must request our “Return Authorization Form” and return the completed to us. A restocking and inspection charge of 20% will be charged on all authorized returns more than (30) days after invoice date. No returns will be accepted after 90 days. A restocking charge may be assess on any return that in our determination was not an error of MSI. • A restocking and inspection charge of 35% will be charged for on all authorized returns more than (60) sixty days after our invoice date. • Goods accepted for return will be on a merchandise credit basis only and we can only accept prepaid ship ments. • Any merchandise returned without approval will be sub ject to an automatic restocking fee with a minimum of 35%.

1. Notify our Customer Service Department in writing or by phone of your request for return authorization. 2. We will mail a “Return Authorization Request” form. Please complete the form with the following information: (A) Our stock number (B) Invoice Number (C) Date of invoice (D) Reason for return 3. When your form has been approved, we will issue you an authorization to return and a label. 4. The following types of goods are not eligible for credit: (A) Custom designed instruments (B) Instruments which have been used, marked or altered in anyway (C) Engraved instruments (D) Discontinued products (E) Sterile products (F) Color coated instruments

Prices subject to change without notice. MSI Precision is not accountable for any errors or omissions that may appear in the catalog.

MSI Precision Specialty Instruments 1220 Valley Forge Road, Building 34 Phoenixville, PA 19460-2628 Phone: 1-800-633-7283 • 1-800-322-4674 • Fax: 1-610-935-5844


Numerical Index

Part Number 208 208A 209-F 210 210A 211 211A 211S 211SA 212 212A 213 213A 214 214A 214S 214SA 215 215A 215-F 216 216A 217 217A 218 218A 219 219A 220 220A 221 221A 222 222A 223 223A 224 224A 229 229A 230 230A 231 231A 232 232A 233 233A 234 234A 235

Page 6 6 17 5 5 5 5 5 5 5 5 5 5 6 6 6 6 5 5 17 5 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6 5 5 6 6 6 6 6 6 7 7 7 7 7 7 6

34

Part Number 235A 236 236A 237 237A 238 238A 239 239A 240 240A 243 243A 248 248 248A 253 253A 254 254A 255 255A 258 258A 261 261A 262 262A 263 263A 264SA 264SA 265 265A 271 271A 272 272A 273 273A 274 274A 277 277A 278 278A 279 279A 280 280A 282

Page 6 6 6 6 6 6 6 6 6 7 7 6 6 6 9 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 5 5 6 6 6 6 7 7 7 7 7 7 7 7 6 6 7 7 7 7 7

Part Number

Page

282A 283 283A 284 284-01 284-01A 284-02 284-02A 284-03 284-03A 284A 287 287A 288 288A 289 289A 290 290A 291 291A 292 292A 293 293A 295 295A 297 297A 298 298A 301-01 301R 302R 307 307A 308 308A 309-F 310 310A 311 311A 311R 311S 311SA 312 312A 313 313A 314

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

7 7 7 7 7 7 7 7 7 7 7 5 5 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 11 15 15 9 9 9 9 17 8 8 8 8 15 8 8 8 8 8 8 9

Part Number 314A 314SA 314SA 315 315A 315-F 316 316A 317 317A 318 318A 319 319A 320 320A 321 321A 322 322A 323 323A 324 324A 329 329A 330 330A 331 331A 332 332A 333 333-01 333A 334 334A 335 335A 336 336A 337 337A 338 338A 339 339A 340 340A 343 343A

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

Page 9 9 9 8 8 17 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 8 8 9 9 9 9 9 9 10 10 10 11 10 10 10 9 9 9 9 9 9 9 9 9 9 10 10 9 9


Numerical Index

Part Number 348A 353 353A 354 354A 355 355A 358 358A 361 361A 362 362A 363 363A 364S 364SA 365 365A 371 371A 372 372A 373 373A 374 374A 377 377A 378 378A 379 379A 380 380A 382 382A 383 383A 384 384-01 384-01A 384-02 384-02A 384-03 384-03A 384A 387 387A 388 388A 389 389A

Page 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 8 8 9 9 9 9 10 10 10 10 10 10 10 10 9 9 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 8 8 10 10 10 10

Part Number 390 390A 391 391A 392 392A 393 393A 395 395A 397 397A 398 398A 511 511t 512 512t 513 513t 520-05 525 525t 526 526t 527 527t 528 528t 533t 566 600 811 813 820-01 820-01 820-02 820-02-01 820-02-02 820-02-03 820-03 820-04 821 822 823 827 834 873 874 877 885 895 897

Page 10 10 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 11 11 11 1 11 11 11 11 14 14 14 14 14 14 25 16 16 11 17 12 12 12 12 12 12 17 16 16 16 17 17 17 17 17 17 17

Part Number 898 9000 9001 9002 9010 9011 9012 9013 9014 N250 N250A N251 N251A N267 N267A N268 N268A N269 N269-01 N269A N281 PABD1010 PABD1010A PABD1010P PABD1010PA PABD1012 PABD1012A PABD1012P PABD1012PA PABD1120 PABD1120A PABD1120P PABD1120PA PABD1123 PABD1123A PABD1123P PABD1123PA PABD1125 PABD1125A PABD1125P PABD1125PA PABD1150 PABD1150A PABD1150P PABD1150PA PABD1158 PABD1158A PABD1158A PABD1158PA PABD1160 PABD1160AP PABD1160P PABD1160PA

Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Page 17 25 25 25 25 25 26 26 25 18 18 18 18 18 18 18 18 18 21 18 18 23 23 23 23 23 23 23 23 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24

Part Number

Page

PABD1162 PABD1162A PABD1162P PABD1162PA PABD1163 PABD1163A PABD1163P PABD1163PA PABD1175 PABD1175A PABD1175P PABD1175PA PABD1180 PABD1180A PABD1180P PABD1180PA PABD1182 PABD1182A PABD1182P PABD1182PA PABD1183 PABD1183A PABD1183P PABD1183PA PABD1184 PABD1184A PABD1184P PABD1184PA PABD1185 PABD1185P PABD1185P PABD1185PA PABD1210 PABD1210A PABD1210P PABD1210PA PABD1311 PABD1315 PABD1824L PABD18275L PAD1824L PAD18275L PDD 011 PDD 111 PDD 112 PDD 113 PDD 211 PDD 311 PDD 411 PDD 511 PDD 611 PDD 711

Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com

24 24 24 24 24 24 24 24 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 24 24 24 24 22 22 2 2 2 2 19 19 19 19 20 20 20 20 20 20

35


Register

Online Today!

Register today and get complete access to our online catalog resource and product search. www. MSIPrecision .com Precise

36

Accurate Corporate Office

Repair Facility

MSI Precision Specialty Instruments 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments 27 Maple Avenue Holbrook, MA 02343

Exact Office Fax

610-935-8181 or 800-633-7283 610-935-5844 or 800-699-2839

Web Email

www.msiprecision.com don@msiprecision.com



Distributed By:

Serpa Inc.

244, 3ième Boulevard Terrasse-Vaudreuil, Québec J7V 5R3

Tél: 800.665.6450 Fax: 514.453.2586

Corporate: 1220 Valley Forge Road Building 34 Phoenixville, PA 19460

MSI Precision Specialty Instruments

Repair Center: 27 Maple Avenue Holbrook, MA 02343

Ph: 800.322.4674 800.633.7283 Fx: 610.935.5844 sales@msiprecision.com www.msiprecision.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.