MYSON ULOW-E2 Brochure and Technical Guide

Page 1

25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:55 Page 2

MYSON ULOW-E2. LOW TEMPERATURE RADIATOR

heatingthroughinnovation. 01.05.2013

Technology


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:56 Page 3

02

Heating Through Innovation

The key challenge for the UK heating industry, both now and in the future, is how to develop new, more energy efficient ways of providing indoor comfort. As one of the UK’s leading brands, MYSON have developed a reputation for maximising the role of innovation and technology in our operations. We are

HEATING THROUGH INNOVATION.

committed to helping improve indoor comfort and, at the same time, reduce national CO2 emissions by developing energy efficient products that are capable of operating effectively at low water temperatures.

MYSON is one of the oldest and most respected names in the heating industry. We have been manufacturing radiators for over 50 years. All MYSON radiators featuring our Eco logo are renewable energy compatible.


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:56 Page 4

Introduction

INTRODUCTION.

Introducing the ultra unique ULOW-E2. The ULOW-E2 is MYSON’s latest product innovation and another exciting addition to our ever growing range of modern, energy efficient heating solutions. The ULOW-E2 is an innovative low water temperature radiator that we have combined with our latest heating technology. The result is an ultra unique

Technology

heating concept that provides high heat outputs at low water temperatures without any compromise on style.

The ULOW-E2 has been awarded the prestigious 2013 red dot award for product design. Every year innovative design products from around the world are selected by a panel of leading experts and awarded this internationally recognised award.

03


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 5

04

Ultra Benefits & Features

ULTRA BENEFITS & FEATURES.

Low temperature compatible

High savings potential

State-of-the-art design

Intelligent controls

Rapid response heating

Central connection technology

A high proportion of radiant heat

Ideal for renovations and new buildings

Extremely easy installation

System compatibility

Summer breeze effect


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 6

Ultra Benefits & Features

05


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 7

Ultra Intelligent

ULTRA INTELLIGENT.

Technology

Automatic intelligence. The ULOW-E2 is a panel radiator with in-built fans and E2 technology. The E2 technology automatically and intelligently controls operation of the in-built fans to ensure maximum performance. The ULOW-E2 has two operating modes - static and dynamic. Static mode is the most efficient way for the ULOW-E2 to operate, as it does not activate the in-built fans and will work like a traditional radiator with the TRV being the main control. Dynamic mode utilises the in-built fans. This mode may be required during winter months when the outside air temperature drops and additional output is required to maintain a comfortable indoor temperature. The intelligence behind the ULOW-E2 is that the fans will only operate when they are required.

06


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 8

Ultra Benefits & Features

07


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 9

08

Ultra Efficient

ULOW-E2 is a low water temperature radiator with in-built fans for enhanced convection, enabling heat sources to operate at their most energy efficient settings. A combination of radiant heat from its front and back water filled panels, plus enhanced convection from in-built fans, mean that the ULOW-E2 produces high heat outputs and rapidly achieves indoor comfort even with lower water

ULTRA EFFICIENT.

temperatures as demonstrated in the chart below.

Traditional Radiators

Traditional boilers Reducing the water temperature of a boiler can increase a heating

70/55/20°C 60/50/20°C

systems performance. Typically this

55/45/20°C 50/40/20°C

would mean radiators would need

45/35/20°C

to increase in size to maintain a

40/35/20°C

comfortable room temperature,

35/30/20°C

however with the ULOW-E2 and its increased outputs, radiators can remain the same size.

40/35/20°C

ULOW-E2


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:57 Page 10

Ultra Efficient

Renewable heat sources 35.0 32.5

27.5 25.0

Ground Source Heat Pump

22.5

Air Source Heat Pump 20.0

Seasonal Performance Factor (SPF)

4.5

17.5 15.0

4

12.5 10.0

3.5

7.5 5.0

3

2.5

2.5

ULOW-E2 in combination with a condensing boiler

30.0

ULOW-E2 in combination with a heat pump

temperature even further to maximise the efficiency of the heat pump (Example 2).

CO2 reduction over a period of 15 years

Old building with a gas boiler and steel elements

There are two benefits to using the ULOW-E2 with renewable technologies such as heat pumps. Either to save space (Example 1) or to reduce the water

CO2 in t

0

CO2 consumption

2

35

40

45

50

55

60

CO2 reduction

Water Temperature (°C)

The graph shows the effect on SPF when the system is operating at ultra low water temperatures.

Example 1

Example 2

Heat Requirement: 800W

Heat Requirement: 800W

Flow & Return: 45°C / 35°C

Flow & Return: 45°C / 35°C

SELECT Compact:

SELECT Compact:

600mm x 1600mm (829W)

600mm x 1600mm (829W)

ULOW-E2:

ULOW-E2:

600mm x 1200mm (817W)

600mm x 1600mm (1090W)

Saving 400mm of space

Flow & Return: 38°C / 33°C* ULOW-E2: 600mm x 1600mm (830W) *Heat pump is now working 7°C lower.

Comparison of the ULOW-E2 in combination with heat pumps or condensing boilers with the CO2 emissions of an existing installation.

09


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 11

10

Ultra Moder n & Ultra Compact

The ULOW-E2 is a very stylish, flat panel design radiator with attractive round

ULTRA MODERN & ULTRA COMPACT.

hole grille and sophisticated control panel. It is available in both black and white colour options. Its appearance will add a modern look and stylish feel to any room or dĂŠcor.

The enhanced convection of the ULOW-E2 means that it delivers higher heat outputs than standard panel radiators of equivalent size. As a consequence, smaller radiators can be installed in individual rooms - an important consideration when operating low water temperature heating systems.


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 12

Ultra Rapid

ULTRA RAPID.

Due to its combination of both radiant heat and enhanced convection, plus intelligent controls that automatically switch between static and dynamic operation, the ULOW-E2 provides a rapid heat response even at low water temperatures. Indoor comfort is quickly and efficiently achieved.

11


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 13

12

Ultra Flexible


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:58 Page 14

Ultra Flexible

ULTRA FLEXIBLE.

More choice, more solutions

Living in comfort all year round

The ULOW-E2 has been specifically designed for optimum performance with

In winter the ULOW-E2 is an

low water temperature heating systems. It can be quickly and easily installed as

efficient low temperature radiator,

a standalone heating solution or in combination with other types of heat emitters

providing a high level of control

suitable for low water temperature heating systems, including underfloor

ensuring perfect indoor comfort

heating, traditional panel radiators and fan convectors.

throughout the home.

A good choice of heat emitters, in a retrofit project for example, may be to install

Summer breeze effect

underfloor heating downstairs in a home, but upstairs, where underfloor

During the summer months

installation costs can be prohibitive, fit rooms with ULOW-E2s instead. The

the summer breeze of the

ULOW-E2 is a flexible heating solution that can help improve the performance

ULOW-E2 provides gentle air

of a heating system, save money on installation and running costs and enhance

movement to create a pleasant

the appearance of any home.

breeze effect.

13


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 15

14

Ultra Simple Installation

ULTRA SIMPLE INSTALLATION.

The ULOW-E2 has been designed to work with MYSON’s innovative central connection system. This simple but extremely clever idea gives complete planning and installation freedom. The position of the connection no longer depends on the length of the radiator. Therefore, there is no need to wait for the radiators to be sized before installation of the system pipework. Simply position the connections at the centre point of where the radiator will be sited and move on! The central connection system is easy to install and provides significant benefits. Once in operation, it will help the room feel warmer, faster, by distributing hot water from the top of the ULOW-E2 downwards. It also helps ensure a balanced and efficient system by directing the cooler water at the bottom of the unit to the return connection.

Please note: A twin entry valve is required for the central connection. This must be purchased separately.


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 16

Ultra Simple Installation

Tool-free service access What is so special about service access for the ULOW-E2 is that not a single tool is required for removing or replacing the component parts. All functional units and electrical components are freely accessible and can be fitted by means of plug connections and clamp-joints. This saves money and time for maintenance and cleaning. The ULOW-E2 is cleaned just the same way as a standard radiator. The fans sit on gliding cradles and can easily be slid out from the side of the radiator.

The sliding cradles for the fans are made of extremely flexible and resistant plastic. They can be bent to an angle of 90째. This is particularly useful for narrow niches and narrow side clearance with walls. Should the fan need to be replaced, press down the sliding cradle by hand and remove it from the plug connection/clamp-joint.

15


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 17

16

Ultra Controllable

TOUCHPAD - CONTROL PANEL

4

9

6

ULTRA CONTROLLABLE.

2 11

10

5

3

7

8

1 1

Thermostat head

2

Temperature scale THERMOSTAT HEAD

3

Main switch ON/OFF

4

Heating icon, RED

5

Cooling icon, BLUE

6

UP button

7

DOWN button

8

Temperature scale TOUCHPAD

9

Boost button

10

Heating/Cooling button

11

Fans


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:59 Page 18

Technical Data

Dimensions. Model

Nominal Height (mm)

Depth* (mm)

Length (mm)

ULOW 040 ULOW 060 ULOW 080 ULOW 100 ULOW 120 ULOW 140 ULOW 160

600 600 600 600 600 600 600

105 105 105 105 105 105 105

400 600 800 1000 1200 1400 1600

TECHNICAL DATA.

*Allow 7mm for back strap.

Performance Data. Model

ULOW 040

ULOW 060

ULOW 080

ULOW 100

ULOW 120

ULOW 140

ULOW 160

Operation Mode Static Comfort Boost Static Comfort Boost Static Comfort Boost Static Comfort Boost Static Comfort Boost Static Comfort Boost Static Comfort Boost

Heat Output (Watts) ΔT10

ΔT15

ΔT20

ΔT25

ΔT30

ΔT35

74 125 147 111 188 220 148 250 294 185 312 367 222 374 440 259 436 514 296 499 587

126 197 231 189 296 345 252 394 461 315 493 576 378 591 690 441 689 806 504 788 921

184 272 317 276 409 475 368 545 634 460 681 792 552 817 950 644 953 1109 736 1090 1267

247 350 407 371 527 609 494 702 813 618 877 1016 741 1052 1218 865 1227 1422 988 1403 1624

314 430 498 471 647 746 628 862 996 785 1077 1244 942 1292 1492 1099 1507 1741 1256 1723 1989

385 512 591 577 770 886 770 1026 1182 962 1281 1476 1154 1537 1771 1346 1793 2067 1539 2051 2361

PLEASE NOTE: ULOW-E2 should be sized based on comfort mode outputs.

NB. Static mode runs without fans. For BTUs multiply Watts by 3.412.

Motor Power and Weight.

Sound Levels.

Model

Motor Power (W)

Unpacked Weight (kg)

Model

No. of Fans

ULOW 040 ULOW 060 ULOW 080 ULOW 100 ULOW 120 ULOW 140 ULOW 160

3.5 4.9 6.4 7.8 9.3 10.8 12.1

17.13 24.59 32.06 39.70 47.16 53.02 62.27

ULOW 040 ULOW 060 ULOW 080 ULOW 100 ULOW 120 ULOW 140 ULOW 160

2 4 6 8 10 12 14

Water Content is approx 7.1 litres per metre length.

Sound Pressure (dBA) (at 2.5m) Comfort

Boost

22.9 24.4 25.4 26.3 26.9 27.5

30.7 32.6 33.7 34.4 35.1 35.6 36.0

Sound levels tested in accordance with ISO 3741. Figures for living room with 100m2 space according to VDI2081, ULOW-E2 type 22 600 (filled with water). Fans with nominal rotation speed of 2000 RPM at 12 VDC.

Connections: 4 x G ½" internal thread and 2 x G ¾" external thread, underside centre

Maximum operating temperature: 60°C

Maximum positive operating pressure: Standard design: 10 bar

Safety class: IP14 Supply voltage: 230 V

17


25597 ULOW E2 Leaflet_Layout 1 18/06/2013 11:55 Page 1

MYSON

MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk

01.05.2013

heatingthroughinnovation.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.