All Product Catalogue R410A Inverter Wall Mounted Y-Series INDOOR UNIT
M5WMY010JR
M5WMY015JR
OUTDOOR UNIT
M5LCY010DR
M5LCY015DR
Btu/h
8,530
11,950
W
2,500
3,500
Btu/h
10,240
12,970
W
3,000
3,800
EER
W/W
3.41
3.30
COP
W/W
3.62
3.61
HEATPUMP MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
INDOOR UNIT
AIR FLOW
158 / 335
l/s / cfm
132 / 279
138 / 293
l/s / cfm
105 / 222
113 / 240
dBA
39 / 25
41 / 27
HEIGHT
mm
288
288
WIDTH
mm
800
800
DEPTH
mm
204
204
dBA
46
49
HEIGHT
mm
550
550
WIDTH
mm
765
765
DEPTH
mm
285
SIZE
285 FLARE VALVE
TYPE PIPE CONNECTION
163 / 346
MEDIUM
SOUND PRESSURE LEVEL UNIT DIMENSION
l/s / cfm
LOW SOUND PRESSURE LEVEL (MAX/MIN)
UNIT DIMENSION
OUTDOOR UNIT
220-240/1/50
V/Ph/Hz HIGH
LIQUID
mm
6.35
6.35
GAS
mm
9.52
12.7
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT. 5) SPECIFICATIONS ARE TENTATIVE VALUES AT THE TIME OF PRINTING. CONSULT YOUR DEALER FOR LATEST INFORMATION.
Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com.
©2009 McQuay International
+1 (800) 432-1342
www.mcquay.com
A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.
AP-MIY-09
HIGHER ENERGY SAVINGS
STYLISH FLAT-PANEL
Higher performance at lower power consumption. • Makes air-conditioners more economically sensible to operate when compared to conventional fixed-speed units. • By using intelligent controls, compressor running speed is matched with air-conditioning load. This achieves significant savings in energy consumption.
Ideal blend of style and function. • The front panel is designed for contemporary style without compromising on function. • Air intake area is designed to ensure smooth air flow profile for better sound quality and optimized air flow volume.
DC INVERTER TECHNOLOGY
R410A REFRIGERANT WITH ZERO-ODP
UNSURPASSED LEVEL OF COMFORT
LONG-TERM RELIABILITY
Reduced wear and tear. • Compared to conventional fixed-speed units, start-stop cycle is lessened. Therefore, compressor lifespan is extended naturally.
25 25
LOWER SOUND LEVEL
More quiet room environment. • With up to five selectable fan speeds, users are given more dBA choices. By selecting Quiet mode, the sound pressure level is reduced down to an unobtrusive 25 dBA. • To quickly cool down the room, turbo mode can be selected for maximum cooling power and highest airflow.
COMPACT G17 HANDSET
Full-featured and easy-to-use. • Prominent temperature display. • Real-time clock display. • Easily accessible buttons for On/Off, Temperature Setting, Fan Speed and Mode control. • Dedicated buttons or Silent and Turbo functions.
Fast Cooling
UNSURPASSED LEVELS OF COMFORT
Set Temperature
Narrow temperature band at ±0.5 deg C. • Working in tandem, the inverter compressor and electronic expansion valve ensures smooth refrigerant flow. • Room temperature variation is never more than 0.5 deg Celsius to ensure optimum comfort for room occupants.
Conventional Air Conditioner
• High starting current • Frequent on/off cycle
Soft-start feature. • High current draw during startup is avoided due to the smooth ramp-up profile of inverter compressor.
Inverter Air Conditioner
• Low starting current • Smooth operation
*R410A Characteristics
1
Time
Conventional System
Refrigerant
ODP*1
GWP*2
R22
0.05
1,700
R410A
0
1,950
*1: Ozone Depletion Potential
Efficiency
Flammability
Toxicity
High
Nonflammable
Low
Providing right conditions for restful sleep. • Once activated, sleep mode ensures a comfortable environment for restful sleep. • Depending on the mode, set temperature is increased / decreased gradually according to normal sleeping temperature patterns.
ling
Sl 0 1/ eep Set On 2 1 2
-1˚C ng
ati
He
-2˚C
Heating mode*
-3˚C
Coo
0 1/ 2 Slee 1 p Se tO
Cooling mode
+1˚C
+0.5˚C
+0.5˚C
n
2
* Heat pump models only Running Current
LOW STARTING CURRENT
The Ozone Depletion Potential (O.D.P.) for R410A is zero. However, it is a green house gas whose Global Warming Potential (G.W.P.) is similar to the high G.W.P. for R22. McQuay is working to develop next generation refrigerants and the products that will use them.
Inverter System
SLEEP FUNCTION
rs
Time
Room Temperature
Hou
Set Temperature
Temperature
Precise & Stable Temperature Control
s
Room comfort level is constantly maintained even when the number of people in the room increases or decreases.
Room Temperature
Temperature
Rapid response time. After quickly reaching Set Temperature, the inverter system constantly adjusts and fine-tunes the cooling/heating capacity to prevent undesired temperature swings.
Ho ur
FLEXIBLE PERFORMANCE
PERSONALIZED FUNCTION
One-button access to your favorite conditions. Allows users to store 2 sets of individual settings including operating mode, temperature, fan speed, and ON/OFF timer according to your specific needs. Each setting can be restored quite conveniently at a later time.
Hours of operation
*2: Global Warming Potential (IPCC2001)
2
All Product Catalogue R410A DC Inverter Wall Mounted Y-Series INDOOR UNIT
M5WMY10JR
M5WMY15JR
OUTDOOR UNIT
M5LCY10DR
M5LCY15DR
Btu/h
8,530
11,950
W
2,500
3,500
Btu/h
10,240
12,970
W
3,000
3,800
EER
W/W
3.41
3.30
COP
W/W
3.62
3.61
HEAT PUMP MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
INDOOR UNIT
AIR FLOW
158 / 335
l/s / cfm
132 / 279
138 / 293
l/s / cfm
105 / 222
113 / 240
dBA
39 / 25
41 / 27
HEIGHT
mm
288
288
WIDTH
mm
800
800
DEPTH
mm
204
204
dBA
46
49
HEIGHT
mm
550
550
WIDTH
mm
765
765
DEPTH
mm
285
SIZE
285 FLARE VALVE
TYPE PIPE CONNECTION
163 / 346
MEDIUM
SOUND PRESSURE LEVEL UNIT DIMENSION
l/s / cfm
LOW SOUND PRESSURE LEVEL (MAX/MIN)
UNIT DIMENSION
OUTDOOR UNIT
220-240/1/50
V/Ph/Hz HIGH
LIQUID
mm
6.35
6.35
GAS
mm
9.52
12.7
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT. 5) SPECIFICATIONS ARE TENTATIVE VALUES AT THE TIME OF PRINTING. CONSULT YOUR DEALER FOR LATEST INFORMATION.
Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com.
©2009 McQuay International
+1 (800) 432-1342
www.mcquay.com
A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.
AP-MIY-09