ﻃﺮﺡ ﺳﻴﺴﺘﻤﻬﺎﻱ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ ﺩﮐﺘﺮ ﻣﺤﻤﺪ ﺣﺴﻦ ﺳﻌﻴﺪﻱ
ﺍﺟﺰﺍﻱ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﻟﻮﻟﻪﻫﺎﻱ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ
ﻟﻮﻟﻪﻫﺎﻱ ﺷﺒﮑﻪ ﺁﺏ ﺑﺎﺭﺍﻥ
ﻟﻮﻟﻪﻫﺎﻱ ﻓﺎﺿﻼﺏ ﺳﺒﮏ
ﻭﺳﺎﻳﻞ ﺑﻬﺪﺍﺷﺘﻲ
ﺩﺭﻳﭽﻪﻫﺎﻱ ﺑﺎﺯﺩﻳﺪ
ﻟﻮﻟﻪﻫﺎﻱ ﺗﻬﻮﻳﻪ
ﻟﻮﻟﻪﻫﺎﻱ ﻓﺎﺿﻼﺏ ﺳﻨﮕﻴﻦ
ﺳﻴﻔﻮﻥ
§ ﻣﺘﺎﺳﻔﺎﻧﻪ ﺩﺭ ﺣﺎﻝ ﺣﺎﺿﺮ ﺗﻌﺪﺍﺩ ﺑﺴﻴﺎﺭ ﮐﻤﻲ ﺍﺯ ﺷﻬﺮﻫﺎﻱ ﺍﻳـﺮﺍﻥ ﺩﺍﺭﺍﻱ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺷﻬﺮﻱ ﺑﻮﺩﻩ ﻭ ﻟﺬﺍ ﻋﻤﺪﺗﺎﹰ ﺍﺯ ﭼﺎﻩ ﺟﺬﺑﻲ ﺍﺳﺘﻔﺎﺩﻩ ﻣﻲﺷﻮﺩ. § ﻣﻌﻤﻮﻻﹰ ﻣﺤﻞ ﭼﺎﻩ ﺟﺬﺑﻲ ﺗﻮﺳـﻂ ﻣﻬﻨـﺪﺱ ﻃـﺮﺍﺡ ﻣﺸـﺨﺺ ﺷـﺪﻩ ﻭ ﺣﺠﻢ ﺁﻥ ﺗﻮﺳﻂ ﭘﻴﻤﺎﻧﮑﺎﺭ ،ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺷﻨﺎﺧﺘﻲ ﮐﻪ ﺍﺯ ﻣﻴﺰﺍﻥ ﺟﺬﺏ ﺧﺎﮎ ﻣﻨﻄﻘﻪ ﺩﺍﺭﺩ ،ﺑﻪ ﻫﻨﮕﺎﻡ ﺍﺟﺮﺍ ﺗﻌﻴﻴﻦ ﻣﻲﮔﺮﺩﺩ. § ﻫﺮﭼﻨﺪ ﺣﺠﻢ ﭼﺎﻩ ﺟﺰﺑﻲ ﺩﺭ ﻧﻘﺸﻪﻫﺎﻱ ﺗﺎﺳﻴﺴﺎﺗﻲ ﻣﺸﺨﺺ ﻧﻤﻲﺷﻮﺩ، ﺗﻘﺮﻳﺒﺎﹰ 8ﻣﺘﺮﻣﮑﻌﺐ ﺑﻪ ﺍﺯﺍﻱ ﻫﺮ ﻧﻔﺮ ﺑﺮﺍﻱ ﺩﻭﺭﻩﺍﻱ 20ﺳﺎﻟﻪ ﮐﺎﻓﻲ ﺍﺳﺖ. § ﻣﺤﻞ ﭼﺎﻩ ﺑﺎﻳﺪ ﺩﺭ ﻣﮑﺎﻧﻲ ﺑﺎﺷﺪ ﮐﻪ ﻭﺯﻥ ﭘﻲﻫـﺎﻱ ﺳـﺎﺧﺘﻤﺎﻥ ﺭﻭﻱ ﺁﻥ ﻧﺒﻮﺩﻩ ﻭ ﺩﺭ ﺻﻮﺭﺕ ﺍﻣﮑﺎﻥ ﺣﺪﺍﻗﻞ ﻋﺒﻮﺭ ﻭ ﻣﺮﻭﺭ ﺍﺯ ﺭﻭﻱ ﺁﻥ ﺍﻧﺠﺎﻡ ﺷﻮﺩ. § ﺍﮔﺮ ﻧﻔﻮﺫ ﺧﺎﮎ ﮐﺎﻓﯽ ﻧﺒﻮﺩﻩ ﻭ ﻳﺎ ﺑﺪﻟﻴﻞ ﺑﺎﻻ ﺑﻮﺩﻥ ﺳﻄﺢ ﺁﺑﻬـﺎﻱ ﺯﻳـﺮ- ﺯﻣﻴﻨﻲ ﺣﻔﺮ ﭼﺎﻩ ﺍﻣﮑﺎﻥﭘﺬﻳﺮ ﻧﺒﺎﺷﺪ ،ﺍﺯ ﺳﭙﺘﻴﮏ ﺗﺎﻧﮏ ﺍﺳﺘﻔﺎﺩﻩ ﻣﻲﺷﻮﺩ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﻬﺪﺍﺷﺘﯽ ﺗﻌﻴﻴﻦ ﻣﺴﻴﺮ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ،ﻗﺎﺋﻢ ﻭ ﻟﻮﻟﻪ ﺍﻓﻘﻲ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ ﺭﻭﻱ ﻧﻘﺸﻪ ﭘﻼﻥ § ﺟﺎﻧﻤﺎﻳﻲ ﻭﺳﺎﻳﻞ ﺑﻬﺪﺍﺷﺘﻲ ﻣﻌﻤﻮﻻﹰ ﺗﻮﺳﻂ ﻣﻬﻨﺪﺱ ﻣﻌﻤﺎﺭ ﺗﻌﻴﻴﻦ ﺷﺪﻩ ﻭ ﺑﺎ ﺗﻮﺟﻪ ﺑـﻪ ﺁﻥ ،ﻣﺴـﻴﺮ ﺷـﺒﮑﻪ ﻓﺎﺿـﻼﺏ ﺗﻮﺳﻂ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ ﻃﺮﺍﺣﻲ ﻣﻲﮔﺮﺩﺩ. § ﻣﺴﻴﺮ ﻟﻮﻟﻪﻫﺎ ﺑﺎﻳﺪ ﺣﺘﻲﺍﻻﻣﮑﺎﻥ ﺳﺎﺩﻩ ﻭ ﻣﺴﺘﻘﻴﻢ ﺑﺎﺷﺪ. § ﮐﻠﻴﻪ ﺍﺗﺼﺎﻻﺕ ﺯﺍﻧﻮ ﻭ ﺳﻪ ﺭﺍﻩ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﺎ ﺍﺗﺼﺎﻝ 45ﺩﺭﺟﻪ ﻃﺮﺍﺣـﻲ ﻭ ﺍﺟـﺮﺍ ﺷـﺪﻩ ﻭ ﺑﺎﻳـﺪ ﺍﺯ ﺍﺗﺼـﺎﻻﺕ 90 ﺩﺭﺟﻪ ﺩﺭ ﻣﺴﻴﺮ ﻋﺒﻮﺭ ﺟﺮﻳﺎﻥ ﺧﻮﺩﺩﺍﺭﻱ ﻧﻤﻮﺩ. § ﺑﻪ ﺩﻟﻴﻞ ﺷﻴﺐﺩﺍﺭ ﺑﻮﺩﻥ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ،ﺣﺘﻲﺍﻻﻣﮑﺎﻥ ﺑﺎﻳﺪ ﺍﺯ ﻃﺮﺍﺣﻲ ﺷـﺒﮑﻪ ﻓﺎﺿـﻼﺏ ﺑـﺎ ﻟﻮﻟـﻪﻫـﺎﻱ ﺍﻓﻘـﻲ ﺑﻠﻨـﺪ ﺍﺟﺘﻨﺎﺏ ﻧﻤﻮﺩ ،ﺯﻳﺮﺍ ﺍﺣﺘﻤﺎﻝ ﮔﺮﻓﺘﮕﻲ ﻟﻮﻟﻪﻫﺎ ﺑﻴﺸﺘﺮ ﺷﺪﻩ ﻭ ﺑﻪ ﻋﻼﻭﻩ ﺍﺭﺗﻔﺎﻉ ﺳﻘﻒ ﮐﺎﺫﺏ ﺟﻬﺖ ﻧﺼﺐ ﻟﻮﻟﻪﻫﺎ ﻧﻴﺰ ﺑـﻴﺶ ﺍﺯ ﺍﻧﺪﺍﺯﻩ ﺯﻳﺎﺩ ﻣﻲﺷﻮﺩ. § ﻟﻮﻟﻪﻫﺎﻱ ﻗﺎﺋﻢ ﻓﺎﺿﻼﺏ ﻋﻤﻮﻣﺎﹰ ﺩﺭ ﮐﻨﺞ ﺩﻳﻮﺍﺭ ﻳﺎ ﺩﺭ ﺷﻔﺖ ﺗﺎﺳﻴﺴﺎﺗﻲ ﻗﺮﺍﺭ ﺩﺍﺩﻩ ﻣﻲﺷﻮﻧﺪ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﻬﺪﺍﺷﺘﯽ ﺗﻌﻴﻴﻦ ﻣﺤﻞ ﺩﺭﻳﭽﻪﻫﺎﻱ ﺑﺎﺯﺩﻳﺪ
§
ﺑﺎﻻﺗﺮﻳﻦ ﻧﻘﻄﻪ ﺩﺭ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ )ﻭﺳﺎﻳﻞ ﺑﻬﺪﺍﺷﺘﻲ ﺧﻮﺩ ﻣﻲﺗﻮﺍﻧﻨﺪ ﺑﻪ ﻋﻨﻮﺍﻥ ﺩﺭﻳﭽﻪ ﺑﺎﺯﺩﻳﺪ ﺍﺳﺘﻔﺎﺩﻩ ﮔﺮﺩﻧﺪ(
§
ﻣﺤﻞ ﺗﻐﻴﻴﺮ ﺍﻣﺘﺪﺍﺩ ﺑﺎ ﺯﺍﻭﻳﻪ ﺑﻴﺸﺘﺮ ﺍﺯ 45ﺩﺭﺟﻪ ﺩﺭ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ
§
ﭘﺎﻳﻴﻦﺗﺮﻳﻦ ﻧﻘﻄﻪ ﻟﻮﻟﻪ ﻗﺎﺋﻢ ﻓﺎﺿﻼﺏ ،ﻗﺒﻞ ﺍﺯ ﺯﺍﻧﻮﻳﻲ ﺍﺗﺼﺎﻝ ﺑﻪ ﻟﻮﻟﻪ ﺍﻓﻘﻲ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ
§
ﺭﻭﻱ ﻟﻮﻟﻪ ﺍﻓﻘﻲ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ ﺩﺭ ﻓﻮﺍﺻﻞ ﺣﺪﺍﮐﺜﺮ 30ﻣﺘﺮﻱ
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﻬﺪﺍﺷﺘﯽ ﺗﻌﻴﻴﻦ ﺗﻌﺪﺍﺩ ﻭﺍﺣﺪ ﻣﺼﺮﻑ ﻭﺳﺎﻳﻞ ﺑﻬﺪﺍﺷﺘﻲ
ﺑﺮﺍﻱ ﺗﺨﻠﻴﻪ ﻓﺎﺿـﻼﺏ ﺍﺯ ﻭﺳـﺎﻳﻞ ﻭ ﺳﻴﺴـﺘﻢ ﻫـﺎﻳﻲ ﻧﻈﻴـﺮ ﭘﻤﭗﻫﺎ ﻭ ﺗﺎﺳﻴﺴﺎﺕ ﮔﺮﻣﺎﻳﺸﻲ -ﺳﺮﻣﺎﻳﺸﻲ ﮐﻪ ﺗﺨﻠﻴـﻪ ﺁﺏ ﻳﺎ ﻓﺎﺿﻼﺏ ﺍﺯ ﺁﻧﻬﺎ ﺑﻪﻃﻮﺭ ﭘﻴﻮﺳﺘﻪ ﻳﺎ ﻧﻴﻤﻪ ﭘﻴﻮﺳﺘﻪ ﺻـﻮﺭﺕ ﻣﻲﮔﻴﺮﺩ ،ﺑﻪ ﺍﺯﺍﻱ ﻫﺮ ﮔﺎﻟﻦ ﺩﺭ ﺩﻗﻴﻘﻪ ﺑﺮﺍﻱ ﺗﺨﻠﻴﻪ ﭘﻴﻮﺳﺘﻪ 2ﻭﺍﺣﺪ ﻣﺼﺮﻑ ﻭ ﺑـﺮﺍﻱ ﺗﺨﻠﻴـﻪ ﻧﻴﻤـﻪ ﭘﻴﻮﺳـﺘﻪ 1ﻭﺍﺣـﺪ ﻣﺼﺮﻑ ﺩﺭ ﻣﺤﺎﺳﺒﺎﺕ ﺍﻧﺪﺍﺯﻩ ﻟﻮﻟﻪ ﻣﻨﻈﻮﺭ ﻣﻲﮔﺮﺩﺩ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﻬﺪﺍﺷﺘﯽ ﺗﻌﻴﻴﻦ ﺷﻴﺐ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﻭ ﻟﻮﻟﻪ ﺍﻓﻘﻲ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ § ﻣﻨﺎﺳﺐﺗﺮﻳﻦ ﺷﻴﺐ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﺷﻴﺐ 2%ﺑﻮﺩﻩ ﻭ ﺑﻬﺘﺮ ﺍﺳﺖ ﺩﺭ ﺗﻤﺎﻡ ﻃﻮﻝ ﺷﺒﮑﻪ ﺛﺎﺑﺖ ﺑﺎﻗﻲ ﺑﻤﺎﻧﺪ. § ﺩﺭ ﺻﻮﺭﺕ ﻧﻴﺎﺯ ﺑﻪ ﺍﺟﺮﺍﻱ ﺷﻴﺐ ﮐﻤﺘﺮ ،ﻣﻘﺪﺍﺭ ﺁﻥ ﻧﺒﺎﻳﺪ ﺍﺯ ﻣﻘﺎﺩﻳﺮ ﻣﻨﺪﺭﺝ ﺩﺭ ﺟﺪﻭﻝ ﺯﻳﺮ ﮐﻤﺘﺮ ﺑﺎﺷﺪ:
ﺷﻴﺐ ﺑﻴﺶ ﺍﺯ ﺣﺪ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﻓﺎﺿﻼﺏ ،ﻣﻮﺟﺐ ﺍﻓﺰﺍﻳﺶ ﺳﺮﻋﺖ ﺳﻴﺎﻝ ﺩﺭ ﻟﻮﻟﻪﻫـﺎ ﻭ ﺍﻳﺠـﺎﺩ ﻣﮑـﺶ ﺳـﻴﻔﻮﻧﻲ ﺩﺭ ﻭﺳﺎﻳﻞ ﺑﻬﺪﺍﺷﺘﻲ ﻣﺘﺼﻞ ﺑﻪ ﻟﻮﻟﻪ ﻣﻲﮔﺮﺩﺩ .ﺑﻨﺎﺑﺮﺍﻳﻦ ﺷﻴﺐ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﻧﺒﺎﻳﺪ ﺍﺯ 4%ﺗﺠﺎﻭﺯ ﮐﻨﺪ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﻬﺪﺍﺷﺘﯽ ﺗﻌﻴﻴﻦ ﻗﻄﺮ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﻭ ﻟﻮﻟﻪﻫﺎﻱ ﻗﺎﺋﻢ
ﻗﻄﺮ ﻧﺎﻣﻲ ﻟﻮﻟﻪ ﻗﺎﺋﻢ ﻓﺎﺿـﻼﺏ ﺍﺯ ﭘـﺎﻳﻴﻦ ﺗـﺎ ﺑـﺎﻻﻱ ﺳﺎﺧﺘﻤﺎﻥ ﺑﻬﺘﺮ ﺍﺳﺖ ﺗﻐﻴﻴﺮ ﻧﮑﻨـﺪ ،ﻣﮕـﺮ ﺁﻧﮑـﻪ ﺩﺭ ﻃﺒﻘﺎﺕ ﺑﺎﻻ ﻗﻄﺮ ﻧﺎﻣﻲ ﻟﻮﻟﻪ ﺍﺯ ﻧﺼﻒ ﻗﻄﺮ ﻧﺎﻣﻲ ﻟﻮﻟﻪ ﺩﺭ ﭘﺎﻳﻴﻦ ﺳﺎﺧﺘﻤﺎﻥ ﮐﻤﺘﺮ ﺷﻮﺩ.
ﺣﺪﺍﻗﻞ ﻗﻄﺮ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﻭ ﻗﺎﺋﻢ ﻓﺎﺿﻼﺏ ﺳـﺒﮏ 2ﺍﻳﻨﭻ ﻭ ﺣـﺪﺍﻗﻞ ﻗﻄـﺮ ﻟﻮﻟـﻪ ﻫـﺎﻱ ﺍﻓﻘـﻲ ﻭ ﻗـﺎﺋﻢ ﻓﺎﺿﻼﺏ ﺳﻨﮕﻴﻦ 4ﺍﻳﻨﭻ ﺑﻮﺩﻩ ﻭ ﻗﻄﺮ ﻫﻴﭻ ﻳـﮏ ﺍﺯ ﻟﻮﻟﻪ ﻫﺎ ﺑﻪ ﻫﻴﭻ ﻋﻨﻮﺍﻥ ﻧﺒﺎﻳﺪ ﺍﺯ ﻗﻄﺮ ﻗﻄﻮﺭﺗﺮﻳﻦ ﻟﻮﻟﻪ ﻣﺘﺼﻞ ﺑﻪ ﺁﻥ ﮐﻤﺘﺮ ﺑﺎﺷﺪ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﻓﺎﺿﻼﺏ ﺑﻬﺪﺍﺷﺘﯽ ﺗﻌﻴﻴﻦ ﻗﻄﺮ ﻟﻮﻟﻪ ﺍﻓﻘﻲ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﺗﻬﻮﻳﻪ ﺳﻴﻔﻮﻧﺎﮊ )ﻣﮑﺶ ﺳﻴﻔﻮﻧﻲ( ﻋﻠﻞ ﺧﺎﻟﯽ ﺷﺪﻥ ﺳﻴﻔﻮﻥ ﻓﺸﺎﺭ ﻣﻌﮑﻮﺱ ﺑﺮﺍﻱ ﺍﺗﺼﺎﻝ ﻣﺠﻤﻮﻋـﻪ ﻟﻮﻟـﻪﻫـﺎﻱ ﻫـﻮﺍﮐﺶ ﺑـﻪ ﻫـﻮﺍﻱ ﺁﺯﺍﺩ ﺩﻭ ﺭﻭﺵ ﻣـﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﻗﺮﺍﺭ ﻣﻲﮔﻴﺮﺩ: § ﻫـﻮﺍﮐﺶ ﻟﻮﻟﻪ ﻗﺎﺋﻢ ) :(Stack Ventﺍﻳﻦ ﻟﻮﻟﻪ ﺩﺭ ﻭﺍﻗﻊ ﺍﻣﺘﺪﺍﺩ ﻟﻮﻟﻪ ﻗﺎﺋﻢ ﻓﺎﺿﻼﺏ ﺍﺳﺖ ﮐﻪ ﺑﺎﻳﺪ ﺑﺪﻭﻥ ﮐﺎﻫﺶ ﻗﻄﺮ ﺗﺎ ﺑﺎﻡ ﺍﺩﺍﻣﻪ ﻳﺎﺑﺪ .ﻃﺒﻴﻌﻲ ﺍﺳﺖ ﮐﻪ ﺍﺯ ﺍﻳﻦ ﻟﻮﻟﻪ ﺗﻨﻬﺎ ﺩﺭ ﻃﺒﻘﻪ ﺁﺧﺮ ﺳﺎﺧﺘﻤﺎﻥ ﻣﻲﺗﻮﺍﻥ ﺍﺳﺘﻔﺎﺩﻩ ﻧﻤﻮﺩ. § ﻟﻮﻟﻪ ﻗﺎﺋﻢ ﻫﻮﺍﮐﺶ ) :(Vent Stackﻟﻮﻟﻪ ﻗﺎﺋﻤﻲ ﺍﺳﺖ ﮐﻪ ﺍﺯ ﭘـﺎﻳﻴﻦ ﺑـﻪ ﻟﻮﻟﻪ ﺍﻓﻘﻲ ﺍﺻﻠﻲ ﺳﺎﺧﺘﻤﺎﻥ ﻳﺎ ﻟﻮﻟﻪ ﻗﺎﺋﻢ ﻣﺘﺼﻞ ﺑﻮﺩﻩ ﻭ ﺍﺯ ﺑﺎﻻ ﺗـﺎ ﺑـﺎﻡ ﺍﺩﺍﻣـﻪ ﺩﺍﺭﺩ .ﻟﻮﻟﻪﻫﺎﻱ ﻗﺎﺋﻢ ﻫﻮﺍﮐﺶ ﻣﻤﮑﻦ ﺍﺳﺖ ﺩﺭ ﻃﺒﻘﻪ ﺁﺧﺮ ﺑﺎ ﻫﻢ ﻳﺎ ﺑﺎ ﻫﻮﺍﮐﺶ ﻟﻮﻟﻪ ﻗﺎﺋﻢ ﻣﺸﺘﺮﮎ ﮔﺮﺩﺩ.
ﺷﺒﮑﻪ ﺗﻬﻮﻳﻪ:
§ § §
ﺧﺎﺭﺝ ﮐﺮﺩﻥ ﮔﺎﺯﻫﺎﯼ ﻓﺎﺿﻼﺏ ﺗﻌﺪﻳﻞ ﻓﺸﺎﺭ ﺳﻴﺴﺘﻢ ﺟﻠﻮﮔﻴﺮﯼ ﺍﺯ ﺧﺎﻟﻲ ﺷﺪﻥ ﺳﻴﻔﻮﻥ
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﺗﻬﻮﻳﻪ ﺗﻌﻴﻴﻦ ﻣﺤﻞ ﻣﺴﻴﺮ ﻟﻮﻟﻪﻫﺎﻱ ﺍﻓﻘﻲ ﻭ ﻗﺎﺋﻢ ﺗﻬﻮﻳﻪ ﺭﻭﻱ ﻧﻘﺸﻪ ﭘﻼﻥ § ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺟﺎﻧﻤﺎﻳﻲ ﻭﺳﺎﻳﻞ ﺑﻬﺪﺍﺷﺘﻲ ﻭ ﻣﺤﺪﻭﺩﻳﺖﻫﺎﻱ ﺍﺟﺮﺍﻳﻲ ،ﻣﺴﻴﺮ ﺷﺒﮑﻪ ﺗﻬﻮﻳﻪ ﺗﻮﺳـﻂ ﻣﻬﻨـﺪﺱ ﺗﺎﺳﻴﺴـﺎﺕ ﻃﺮﺍﺣﻲ ﻣﻲﮔﺮﺩﺩ .ﺍﺯ ﺁﻧﺠﺎ ﮐﻪ ﻋﻤﻮﻣﺎﹰ ﻧﻤﻲﺗﻮﺍﻥ ﺑﺮﺍﻱ ﻫﺮ ﻭﺳﻴﻠﻪ ﺑﻬﺪﺍﺷﺘﻲ ﺗﻬﻮﻳﻪ ﺟﺪﺍﮔﺎﻧﻪ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺖ ،ﺍﻳـﻦ ﻣﺮﺣﻠـﻪ ﻣﻬﻤﺘﺮﻳﻦ ﻗﺴﻤﺖ ﺩﺭ ﻃﺮﺍﺣﻲ ﺳﻴﺴﺘﻢ ﻓﺎﺿﻼﺏ ﻣﺤﺴﻮﺏ ﻣﻲﺷﻮﺩ. ﺗﻌﻴﻴﻦ ﻗﻄﺮ ﻟﻮﻟﻪﻫﺎﻱ ﻫﻮﺍﮐﺶ ﺟﺪﺍﮔﺎﻧﻪ ،ﻣﺸﺘﺮﮎ ﻭ ﺷﺎﺧﻪ ﺍﻓﻘﻲ § ﻗﻄﺮ ﺍﻳﻦ ﻟﻮﻟﻪﻫﺎ ﻧﺒﺎﻳﺪ ﺍﺯ ¼ 1ﺍﻳﻨﭻ ﻳﺎ ﻧﺼﻒ ﻗﻄﺮ ﻟﻮﻟﻪ ﻓﺎﺿﻼﺏ ﻣﺘﺼﻞ ﺑﻪ ﻭﺳﻴﻠﻪ ﺑﻬﺪﺍﺷﺘﻲ ﮐﻮﭼﮑﺘﺮ ﺑﺎﺷﺪ .ﭼﻨﺎﻧﭽﻪ ﻃﻮﻝ ﻟﻮﻟﻪ ﻫﻮﺍﮐﺶ ﺗﺎ ﻣﺤﻞ ﺍﺗﺼﺎﻝ ﺑﻪ ﻟﻮﻟﻪ ﻫﻮﺍﮐﺶ ﻗﺎﺋﻢ ﻳﺎ ﻟﻮﻟﻪ ﻗـﺎﺋﻢ ﻫـﻮﺍﮐﺶ ﺑـﻴﺶ ﺍﺯ 12ﻣﺘـﺮ ﺑﺎﺷـﺪ ،ﻗﻄـﺮ ﻟﻮﻟـﻪ ﻫﻮﺍﮐﺶ ﺑﺎﻳﺪ ﻳﮏ ﺍﻧﺪﺍﺯﻩ ﺑﺰﺭﮔﺘﺮ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮﺩ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﺗﻬﻮﻳﻪ ﺗﻌﻴﻴﻦ ﻗﻄﺮ ﻟﻮﻟﻪﻫﺎﻱ ﻫﻮﺍﮐﺶ ﻗﺎﺋﻢ ﻭ ﻫﻮﺍﮐﺶ ﻟﻮﻟﻪ ﻗﺎﺋﻢ
§ ﺍﺭﺗﻔﺎﻉ ﺍﻧﺘﻬﺎﻱ ﻟﻮﻟﻪ ﻫﻮﺍﮐﺶ ﺩﺭ ﺭﻭﻱ ﺑﺎﻡ ﺍﺯ ﮐﻒ ﺗﻤﺎﻡ ﺷﺪﻩ ﺣﺪﺍﻗﻞ 30ﺳـﺎﻧﺘﻴﻤﺘﺮ ﻭ ﭼﻨﺎﻧﭽﻪ ﺭﻭﻱ ﺑﺎﻡ ﺍﻣﮑﺎﻥ ﺭﻓﺖ ﻭ ﺁﻣﺪ ﻭﺟـﻮﺩ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ ﺣﺪﺍﻗﻞ 2/2ﻣﺘﺮ ﺍﺳﺖ. § ﻓﺎﺻﻠﻪ ﺍﻓﻘـﻲ ﺍﻧﺘﻬـﺎﻱ ﻟﻮﻟـﻪ ﻫـﻮﺍﮐﺶ ﺍﺯ ﻫﺮﮔﻮﻧﻪ ﺩﺭ ،ﭘﻨﺠﺮﻩ ﺑﺎﺯﺷﻮ ﻳﺎ ﺩﻫﺎﻧـﻪ ﻭﺭﻭﺩﻱ ﺳﻴﺴﺘﻢ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ ﺣﺪﺍﻗﻞ 3ﻣﺘﺮ ﺍﺳﺖ، ﻣﮕﺮ ﺁﻧﮑﻪ ﺍﻧﺘﻬﺎﻱ ﻟﻮﻟﻪ ﻫﻮﺍﮐﺶ ﺣﺪﺍﻗﻞ 60 ﺳﺎﻧﺘﻴﻤﺘﺮ ﺑﺎﻻﺗﺮ ﺍﺯ ﻧﻘﻄـﻪ ﻣـﻮﺭﺩ ﻧﻈـﺮ ﻗـﺮﺍﺭ ﮔﻴﺮﺩ.
ﻃﺮﺍﺣﻲ ﺷﺒﮑﻪ ﺁﺏ ﺑﺎﺭﺍﻥ §
ﺟﺪﺍﻭﻝ ﺑﺮ ﻣﺒﻨﺎﻱ ﺣﺪﺍﮐﺜﺮ ﺑﺎﺭﺵ 1ﺍﻳﻨﭻ ﺑﺮ ﺳﺎﻋﺖ ﺍﺳﺖ.
§ ﭼﻨﺎﻧﭽﻪ ﺩﺭ ﻣﺠﺎﻭﺭﺕ ﺑﺎﻡ ،ﺩﻳﻮﺍﺭﻱ ﺑﺎﺷﺪ ﮐﻪ ﺁﺏ ﺑﺎﺭﺍﻥ ﭘـﺲ ﺍﺯ ﺑﺮﺧﻮﺭﺩ ﺑﻪ ﺁﻥ ﺭﻭﻱ ﺑﺎﻡ ﺟﺎﺭﻱ ﺷﻮﺩ ،ﺑﺮﺍﻱ ﺍﻧﺠﺎﻡ ﻣﺤﺎﺳـﺒﺎﺕ ﺑﺎﻳﺪ ﻧﺼﻒ ﻣﺴﺎﺣﺖ ﺩﻳﻮﺍﺭ ﺑﻪ ﺳﻄﺢ ﺑﺎﻡ ﺍﺿﺎﻓﻪ ﮔﺮﺩﺩ.