ﺑﻪ ﻧﺎﻡ ﺁﻥﻛﻪ ﺟﺎﻥ ﺭﺍ ﻓﻜﺮﺕ ﺁﻣﻮﺧﺖ ﺷﻤﺎﺭﻩ ﺳﻰﺍﻡ -ﻓﺮﻭﺭﺩﻳﻦ 89
ﺩﺭ ﺍﻳﻦ ﺷﻤﺎﺭﻩ ﻣﻰﺧﻮﺍﻧﻴﺪ: ﺗﺎﺯﻩﻫﺎﻯ ﺗﻬﻮﻳﻪ2 ...................................................................................................
ﻧﺸﺮﻳﻪ ﺍﺭﻭﻧﺪ
ﻛﻤﭙﺮﺳﻮﺭﻫﺎﻯ ﺩﻭﺍﺭ ﺗﺮﺍﻛﻤﻰ ﺑﺎ ﻛﻴﻔﻴﺖ ﺑﺎﻻ 4 .....................................................
ﺷﻤﺎﺭﻩ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺑﻴﻦﺍﻟﻤﻠﻠﻰ: 1684-4270
ﻧﺸــﺎﻧﻰ :ﻛــﺮﺝ ،ﻧﺴﻴﻢﺷــﻬﺮ ،ﺳــﻪﺭﺍﻩ ﺁﺩﺭﺍﻥ ،ﺑــﻪ ﺳــﻤﺖ ﺷــﻬﺮﻳﺎﺭ ،ﺍﻧﺘﻬــﺎﻯ ﺧﻴﺎﺑــﺎﻥ ﺳــﻌﺪﻯ. ﺷﻤﺎﺭﻩﻫﺎﻯ ﻭﺍﺣﺪ ﻓﺮﻭﺵ )ﻛﺪ :(021 88802677-8ﻭ 88739880-2ﻭ 88504770-4 ﺷﻤﺎﺭﻩﻫﺎﻯ ﻭﺍﺣﺪ ﻓﺮﻭﺵ )ﻛﺪ :(0229 4585899ﻭ 4586036ﻭ 4584983-7 ﺷﻤﺎﺭﻩﻫﺎﻯ ﻓﺎﻛﺲ ﻭﺍﺣﺪ ﻓﺮﻭﺵ: 0229-4585079ﻭ 021-88766794 ﺷﻤﺎﺭﻩﻫﺎﻯ ﻛﺎﺭﺧﺎﻧﻪ )ﻛﺪ :(0229 4585657-8ﻭ 4584998ﻭ 4584717 ﺷﻤﺎﺭﻩ ﻓﺎﻛﺲ ﻛﺎﺭﺧﺎﻧﻪ )ﻛﺪ :(0229 4584198 ﭘﺴﺖ ﺍﻟﻜﺘﺮﻭﻧﻴﻜﻰ:
ﺍﻧﺘﺨﺎﺏ ﻣﺒﺮﺩ ﭼﻴﻠﺮﻫﺎ 38....................................................................................
w w w. a r v a n d c o r p . c o m
ﻧﮕﺎﻫﻰ ﺑﻪ 40 ..................................................................................HCFC - 22
info@arvandcorp.com
ﻧﺸﺎﻧﻰ ﺍﻳﻨﺘﺮﻧﺖ: ﻭﺍﺣﺪ ﻓﺮﻭﺵ:
ﺻﺪﺍ ﺩﺭ ﺗﺠﻬﻴﺰﺍﺕ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ 15 .................................................................. ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﻳﺦﺯﺩﮔﻰ ﻭ ﻛﺎﻫﺶ ﺻﺪﺍﻯ ﺳﻴﺴﺘﻢﻫﺎﻯ ﺁﺏ ﺳﺮﺩ 18......... ﺑﺎﺯﻳﺎﺑﻰ ﮔﺮﻣﺎ ﺍﺯ ﭼﻴﻠﺮﻫﺎﻯ ﻫﻮﺍﻳﻰ 25 .................................................................. ﺗﺠﻬﻴﺰﺍﺕ ﺟﺎﻧﺒﻰ ﻓﻦ 34 .....................................................................................
sales@arvandcorp.com
ﺻﺎﺣﺐ ﺍﻣﺘﻴﺎﺯ :ﺷﺮﻛﺖ ﺻﻨﺎﻳﻊ ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻣﺪﻳﺮ ﻣﺴﻮﻭﻝ :ﻣﻬﻨﺪﺱ ﻣﻨﻮﭼﻬﺮ ﺷﺠﺎﻋﻰ ﺳﺮﺩﺑﻴﺮ :ﻣﻬﻨﺪﺱ ﺣﺴﻦ ﺑﻬﺮﺍﻣﻰ
ﻋﻼﻗﻪﻣﻨﺪﺍﻥ ﺟﻬﺖ ﺩﺭﻳﺎﻓﺖ ﺭﺍﻳﮕﺎﻥ ﺍﻳﻦ ﻧﺸﺮﻳﻪ ﻭ ﺍﺭﺳﺎﻝ ﺁﺛﺎﺭ ﺧﻮﺩ ﻣﻰﺗﻮﺍﻧﻨﺪ ﺑﺎ ﻭﺍﺣﺪ ﺭﻭﺍﺑﻂﻋﻤﻮﻣﻰ ﺷﺮﻛﺖ ﺻﻨﺎﻳﻊ ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻳﺎ ﺍﺯ ﻃﺮﻳﻖ ﺻﻨﺪﻭﻕ ﭘﺴﺘﻰ 37685 - 113ﺍﻗﺪﺍﻡ ﻧﻤﺎﻳﻨﺪ.
ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻣﻄﺎﻟﺐ ﻭ ﺗﺼﺎﻭﻳﺮ ﻧﺸﺮﻳﻪ ﺍﺭﻭﻧﺪ ﺑﺎ ﺫﻛﺮ ﻣﻨﺒﻊ ﺑﻼﻣﺎﻧﻊ ﺍﺳﺖ. ﻋﻼﻗﻪﻣﻨﺪﺍﻥ ﺑﻪ ﺩﺭﺝ ﻣﻄﻠﺐ ﺩﺭ ﺍﻳﻦ ﻧﺸﺮﻳﻪ ﻣﻰﺗﻮﺍﻧﻨﺪ ﺁﺛﺎﺭ ﺧﻮﺩ ﺭﺍ ﺑﻪ ﻧﺸﺎﻧﻰ ﻧﺸﺮﻳﻪ ﺍﺭﺳﺎﻝ ﻧﻤﺎﻳﻨﺪ. ﺍﺭﻭﻧﺪ ﺩﺭ ﺭﺩ ،ﻗﺒﻮﻝ ﻳﺎ ﺍﺻﻼﺡ ﻭ ﻭﻳﺮﺍﻳﺶ ﻣﻘﺎﻻﺕ ﺁﺯﺍﺩ ﺍﺳﺖ. ﻣﻘﺎﻻﺕ ﺍﺭﺳﺎﻟﻰ ﻋﻮﺩﺕ ﺩﺍﺩﻩ ﻧﺨﻮﺍﻫﺪ ﺷﺪ.
ARVAND Internal Magazine Managing Director: M. Shojaei Editor in chief: H. Bahrami
ﺻﻔﺤﻪ / 2ﺷﻤﺎﺭﻩ 30
ﻧﺮﻡﺍﻓﺰﺍﺭ ﺗﺠﺰﯾﻪ ﻭ ﺗﺤﻠﯿﻞ ﺍﻧﺮﮊﯼ ﺷﺮﮐﺖ Bentleyﻧﺮﻡﺍﻓﺰﺍﺭ ﺟﺪﯾﺪﯼ ﺭﺍ
ﺗﺎﺯﻩﻫﺎﻯ ﺗﻬﻮﻳﻪ
ﺑﻪ ﻧــﺎﻡ Hevacomp Simulator V8i ﻃﺮﺍﺣﯽ ﮐﺮﺩﻩ ﺍﺳــﺖ ﮐﻪ ﻗﺎﺑﻠﯿﺖ ﺗﺠﺰﯾﻪ ﻭ ﺗﺤﻠﯿﻞ ﺍﻧﺮﮊﯼ ﺳــﺎﺧﺘﻤﺎﻥ ﺭﺍ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺭﻭﺵ ﺷﺒﯿﻪﺳــﺎﺯﯼ ﺩﯾﻨﺎﻣﯿــﮏ ﺩﺍﺭﺩ .ﺍﯾﻦ ﻧﺮﻡﺍﻓﺰﺍﺭ ﺍﺯ ﯾﮏ ﺑﺎﻧــﮏ ﺍﻃﻼﻋﺎﺗﯽ ﺑﺎ ﺑﯿﺶ
ﺩﯾﮓ ﺗﻘﻄﯿﺮﯼ ﺟﺪﯾﺪ ﺷﺮﮐﺖ Raypackﺑﻪﺯﻭﺩﯼ ﺩﯾﮓﻫﺎﯼ ﺗﻘﻄﯿــﺮﯼ ﺟﺪﯾﺪ ﺧــﻮﺩ ﺭﺍ ﺑﺎ ﻧــﺎﻡ ﺗﺠﺎﺭﯼ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
XFyreﺩﺭ ﻇﺮﻓﯿﺖﻫﺎﯼ ﻣﺨﺘﻠﻒ ﺑﻪ ﺑﺎﺯﺍﺭ ﻋﺮﺿﻪ ﻣﯽﮐﻨﺪ .ﺍﯾــﻦ ﺩﯾﮓﻫﺎ ﺑﻪ ﮔﻮﻧﻪﺍﯼ
ﭘﺎﯾﺪﺍﺭ ﺧﻮﺍﻫﺪ ﺑﻮﺩ«.
ﺍﻋﻼﻡ ﻓﻬﺮﺳﺖ ﻣﻮﺍﺩ ﺷﯿﻤﯿﺎﯾﯽ ﻏﯿﺮ ﻗﺎﺑﻞ ﺍﺳﺘﻔﺎﺩﻩ ﺩﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎ ﺍﺧﯿﺮﺍ ﺗﻌﺪﺍﺩﯼ ﺍﺯ ﻧﻬﺎﺩﻫﺎﯼ ﺩﻭﻟﺘﯽ ﺩﺭ ﮐﺸــﻮﺭ ﺁﻣﺮﯾﮑﺎ ﻓﻬﺮﺳﺘﯽ ﺍﺯ ﻣﻮﺍﺩ ﺷﯿﻤﯿﺎﯾﯽ ﺭﺍ ﺗﻬﯿــﻪ ﮐﺮﺩﻩﺍﻧــﺪ ﮐﻪ ﻣﻮﺟــﺐ ﺑﻪ ﺧﻄﺮ
ﺍﺯ ﺩﻭﻫﺰﺍﺭﻭﻧﻬﺼﺪ ﻣﻨﻄﻘﻪ ﺩﺭ ﺳﺮﺍﺳــﺮ ﺩﻧﯿﺎ
ﺍﻓﺘﺎﺩﻥ ﺳــﻼﻣﺖ ﺍﻧﺴﺎﻥ ﻣﯽﺷﻮﺩ .ﺩﺭ ﺍﯾﻦ
ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﮐﻨﺪ ﻭ ﺗﺠﺰﯾﻪ ﻭ ﺗﺤﻠﯿﻞ ﺭﺍ ﺑﺎ
ﻓﻬﺮﺳــﺖ ،ﺗﻤﺎﻡ ﻣﻮﺍﺩ ﺷﯿﻤﯿﺎﯾﯽ ﺑﻪ ﭼﺸﻢ
ﻓﺼﻞ ﺗﻄﺒﯿﻖ ﻣﯽﺩﻫﺪ .ﻻﺯﻡ ﺑﻪ ﺫﮐﺮ ﺍﺳﺖ
ﻣﯽﺧﻮﺭﺩ ﮐﻪ ﺗﺎﺛﯿــﺮ ﻧﺎﻣﻄﻠﻮﺑﯽ ﺑﺮ ﻭﺿﻌﯿﺖ
ﮐﻪ ﺍﯾﻦ ﻧﺮﻡﺍﻓﺰﺍﺭ ﻗﺎﺑﻠﯿﺖ ﮐﺎﺭﮐﺮﺩ ﯾﮏﭘﺎﺭﭼﻪ
ﺳــﻼﻣﺖ ﺍﻧﺴــﺎﻥ ﺑﺮ ﺟــﺎﯼ ﻣﯽﮔﺬﺍﺭﻧﺪ ﻭ
ﺑﺎ ﻧﺮﻡﺍﻓﺰﺍﺭ ﻣﺪﻝﺳــﺎﺯﯼ EnergyPlusﺭﺍ
ﺍﺣﺘﻤﺎﻝ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺁﻥﻫﺎ ﺩﺭ ﻗﺴﻤﺖﻫﺎﯼ
ﻧﯿﺰ ﺩﺍﺭﺩ ﮐﻪ ﺗﻮﺳــﻂ ﻭﺯﺍﺭﺕ ﻧﯿﺮﻭﯼ ﺍﯾﺎﻻﺕ
ﻣﺨﺘﻠــﻒ ﯾﮏ ﺳــﺎﺧﺘﻤﺎﻥ ﻭﺟــﻮﺩ ﺩﺍﺭﺩ.
ﻣﺘﺤﺪﻩ ﻣﻨﺘﺸﺮ ﺷﺪﻩ ﺍﺳﺖ.
ﺷﺮﮐﺖ Perkins&Willsﻧﯿﺰ ”ﻓﻬﺮﺳﺖ
ﺍﻧﺘﺸﺎﺭ ﺍﺳﺘﺎﻧﺪﺍﺭ 189/1
ﭘﯿﺶﮔﯿﺮﺍﻧــﻪﺍﯼ“ ﺭﺍ ﺍﯾﺠــﺎﺩ ﮐﺮﺩﻩ ﺍﺳــﺖ
ﺍﻧﺠﻤــﻦ ،ASHRAEﺍﺳــﺘﺎﻧﺪﺍﺭﺩ
ﮐــﻪ ﺑﻪ ﺻــﻮﺭﺕ ﺁﻧﻼﯾﻦ ﻗﺎﺑﻠﯿــﺖ ﺗﺒﺎﺩﻝ ﻭ
ANSI/ASHREA/USGBC/ 1/189
ﺟﺴﺖﻭﺟﻮﯼ ﺍﻃﻼﻋﺎﺕ ﺭﺍ ﺩﺭ ﺯﻣﯿﻨﻪ ﻣﻮﺍﺩ
IESﺭﺍ ﻣﻨﺘﺸﺮ ﺳﺎﺧﺖ .ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻃﺮﺍﺣﯽ
ﺷﯿﻤﯿﺎﯾﯽ ﺩﺍﺭﺩ ﻭ ﻣﯽﺗﻮﺍﻥ ﻣﻮﺍﺩ ﺷﯿﻤﯿﺎﯾﯽ
ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺳــﺒﺰ ﺑﺎ ﮐﺎﺭﺁﻣﺪﯼ ﺑﺎﻻ )ﺑﻪ
ﻣﺨﺘﻠــﻒ ﺭﺍ ﺑﻪ ﺻﻮﺭﺕ ﺍﻟﻔﺒﺎﯾــﯽ ﺭﻭﯼ ﺁﻥ
ﺑــﻮﺩ .ﺍﺯ ﻭﯾﮋﮔﯽﻫﺎﯼ ﻣﻨﺤﺼــﺮ ﺑﻪ ﻓﺮﺩ ﺍﯾﻦ
ﺍﺳﺘﺜﻨﺎﯼ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﮐﻮﺗﺎﻩ ﻣﺴﮑﻮﻧﯽ(
ﺩﯾﮓﻫــﺎ ﻣﯽﺗﻮﺍﻥ ﺑﻪ ﺳﯿﺴــﺘﻢ ﻋﯿﺐﯾﺎﺑﯽ
ﺟﺴــﺖﻭﺟﻮ ﻭ ﺗﺎﺛﯿــﺮ ﻫﺮ ﯾــﮏ ﺍﺯ ﺁﻥﻫﺎ ﺭﺍ
ﻧﺨﺴﺘﯿﻦ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺳﺒﺰ
ﻣﺮﮐــﺰﯼ ﺁﻥﻫﺎ ﺍﺷــﺎﺭﻩ ﮐﺮﺩ ﮐــﻪ ﻋﻼﻭﻩ ﺑﺮ
ﺑﺮ ﺳﻼﻣﺖ ﺍﻧﺴــﺎﻥ ﻣﻄﺎﻟﻌﻪ ﮐﺮﺩ .ﻻﺯﻡ ﺑﻪ
ﺗﺠﺎﺭﯼ ﺩﺭ ﺁﻣﺮﯾﮑﺎ ﺍﺳﺖ.
ﻃﺮﺍﺣﯽ ﺷﺪﻩﺍﻧﺪ ﮐﻪ ﺗﺤﺖ ﺑﺎﺭ ﮐﺎﻣﻞ ﺑﺎﺯﺩﻩ ﺁﻥﻫــﺎ ﺑﺮﺍﺑﺮ ﺑﺎ ﻧﻮﺩﻭﭼﻬــﺎﺭ ﺩﺭﺻﺪ ﻭ ﺩﺭ ﺑﺎﺭ ﺟﺰﯾﯽ ﺑﺎﺯﺩﻩ ﺁﻥﻫﺎ ﺗﺎ ﻧﻮﺩﻭﻧﻪ ﺩﺭﺻﺪ ﺧﻮﺍﻫﺪ
ﻧﺸــﺎﻥ ﺩﺍﺩﻥ ﻭﺿﻌﯿﺖ ﮐﺎﺭﮐﺮﺩ ﺳﯿﺴﺘﻢ ﺑﻪ
ﺍﯾﻦ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻣﺴﺎﯾﻠﯽ ﭼﻮﻥ ﭘﺎﯾﺪﺍﺭﯼ
ﺻﻮﺭﺕ ﺩﺍﺋﻤﯽ ،ﻗﺎﺑﻠﯿﺖ ﺫﺧﯿﺮﻩ ﺍﻃﻼﻋﺎﺕ
ﺯﻣﯿــﻦ ،ﺳــﻄﺢ ﮐﺎﺭﺁﻣﺪﯼ ﻣﺼــﺮﻑ ﺁﺏ ﻭ
ﮐﺎﺭﮐﺮﺩ ﻭ ﻋﯿﺐﯾﺎﺑﯽ ﺳﯿﺴﺘﻢ ﺭﺍ ﺩﺍﺭﺩ.
ﺍﻧﺮﮊﯼ ،ﮐﯿﻔﯿــﺖ ﻓﻀﺎﯼ ﺩﺍﺧﻠــﯽ ،ﺍﺛﺮﺍﺕ
ﺳﯿﺴﺘﻢ ﮔﺮﻣﺎﯾﺶ ﺧﻮﺭﺷﯿﺪﯼ
ﺳــﺎﺧﺘﻤﺎﻥ ﺑﺮ ﺟــﻮ ،ﻣﺼﺎﻟــﺢ ﻭ ﻣﻨﺎﺑﻊ ﺭﺍ
ﺫﮐﺮ ﺍﺳــﺖ ﮐﻪ ﻫﺮ ﯾﮏ ﺍﺯ ﻣﺪﺧﻞﻫﺎﯼ ﺍﯾﻦ ﻓﻬﺮﺳﺖ ﺑﻪ ﺗﻮﺻﯿﻒ ﺧﻮﺍﺹ ﻣﻮﺍﺩ ﺷﯿﻤﯿﺎﯾﯽ ﻣﯽﭘــﺮﺩﺍﺯﺩ .ﺩﺭ ﺁﻥ ﻟﯿﻨﮏﻫﺎﯼ ﺩﯾﮕﺮﯼ ﺑﻪ ﭘﺎﯾﮕﺎﻩﻫﺎﯼ ﺍﻃﻼﻉﺭﺳﺎﻧﯽ ﺩﻭﻟﺘﯽ ﺍﺭﺍﺋﻪ ﺷﺪﻩ ﺍﺳﺖ ﮐﻪ ﺩﺭ ﺁﻥﻫﺎ ﻓﻬﺮﺳﺖ ﻣﻮﺍﺩ ﺷﯿﻤﯿﺎﯾﯽ
ﺷــﺮﮐﺖ Tacoﺍﺧﯿــﺮﺍ ﺳﯿﺴــﺘﻢ
ﭘﻮﺷﺶ ﻣﯽﺩﻫﺪ .ﮔﻮﺭﺩﻭﻥ ﻫﻮﻟﻨﺲ ،ﺭﯾﯿﺲ
ﮔﺮﻣﺎﯾﺶ ﺧﻮﺭﺷــﯿﺪﯼ ﺟﺪﯾــﺪﯼ ﺭﺍ ﺑﻪ ﻧﺎﻡ
ﺍﯾــﻦ ﺍﻧﺠﻤﻦ ﺿﻤﻦ ﺑﯿــﺎﻥ ﺍﯾﻦ ﻣﻄﻠﺐ ﮐﻪ
SPS - PC - 1ﻃﺮﺍﺣــﯽ ﮐــﺮﺩﻩ ﺍﺳــﺖ
ﻗﻮﺍﻧﯿﻦ ﻣﻮﺟﻮﺩ ﺩﺭ ﺍﯾﻦ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻣﯽﺗﻮﺍﻧﺪ
ﮐــﻪ ﺩﺭ ﺁﻥ ﺑﺮﺍﯼ ﮔﺮﻣﺎﯾﺶ ﺁﺏ ﺍﺯ ﯾﮏ ﻣﺪﺍﺭ
ﺍﺯ ﻃﺮﯾﻖ ﻃﺮﺍﺣﯽ ﻭ ﺳﺎﺧﺖ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯾﯽ
ﺑﺴﺘﻪ ﻭ ﯾﮏ ﻭﺍﺣﺪ ﭘﯿﺶﺳﺎﺧﺘﻪ ﯾﮏﭘﺎﺭﭼﻪ
ﺑﺎ ﮐﺎﺭﺁﻣﺪﯼ ﺑــﺎﻻ ﻭ ﺍﻗﺪﺍﻣــﺎﺕ ﻋﻤﻠﯿﺎﺗﯽ،
ﮐﻨﻔﺮﺍﻧﺲ ﺯﻣﺴـﺘﺎﻧﯽ ASHRAE 2010
ﺍﺳﺘﻔﺎﺩﻩ ﺷﺪﻩ ﺍﺳﺖ .ﺍﯾﻦ ﺳﯿﺴﺘﻢ ﺷﺎﻣﻞ
ﺳﺒﺐ ﮐﺎﻫﺶ ﺍﺛﺮﺍﺕ ﻣﻨﻔﯽ ﻣﺤﯿﻄﯽ ﺷﻮﺩ،
ﻃﺒﻖ ﺑﺮﻧﺎﻣﻪﺭﯾﺰﯼﻫﺎﯼ ﺻﻮﺭﺕﮔﺮﻓﺘﻪ،
ﭘﻤﭗ ﺳﺮﻋﺖ ﻣﺘﻐﯿﺮ ،ﺷﯿﺮﻫﺎﯼ ﺗﻮﭘﯽ ﺑﺮﺍﯼ
ﮔﻔــﺖ» :ﺩﺭ ﻧﻬﺎﯾــﺖ ﻧﯿﺰ ،ﻫــﺪﻑ ﻧﻪﺗﻨﻬﺎ
ﮐﻨﻔﺮﺍﻧﺲ ﺯﻣﺴﺘﺎﻧﯽ ﺍﻧﺠﻤﻦ ASHRAE
ﻗﻄــﻊ ﻭ ﻭﺻﻞ ﺟﺮﯾﺎﻥ ،ﻭﺍﺣــﺪ ﻫﻮﺍﮔﯿﺮﯼ،
ﮐﺎﺭﺁﻣﺪﯼ ﺍﻧﺮﮊﯼ ،ﺑﻠﮑﻪ ﺗﻮﺍﺯﻥ ﻣﺴــﻮﻭﻟﯿﺖ
ﺩﺭ ﺳــﺎﻝ 2010ﺩﺭ ﺷــﻬﺮ ﺍﻭﺭﻻﻧﺪﻭ ﺍﯾﺎﻟﺖ
ﺟﺮﯾﺎﻥﺳــﻨﺞ ﻭ ﺗﺠﻬﯿــﺰﺍﺕ ﺍﯾﻤﻨﯽ ﺍﺳــﺖ
ﻣﺤﯿﻄﯽ ،ﮐﺎﺭﺁﻣﺪﯼ ﻣﻨﺎﺑﻊ ،ﺭﻓﺎﻩ ﻭ ﺁﺳﺎﯾﺶ
ﻓﻠﻮﺭﯾــﺪﺍ ﺑﺮﮔﺰﺍﺭ ﺧﻮﺍﻫﺪ ﺷــﺪ .ﻣﺤﻮﺭﻫﺎﯼ
ﮐﻪ ﻓﻘﻂ ﺑــﺎ ﭘﻨﺞ ﺭﺍﺑﻂ ﺑــﻪ ﯾﮑﺪﯾﮕﺮ ﻧﺼﺐ
ﺳــﺎﮐﻨﺎﻥ ﻭ ﺣﺴﺎﺳــﯿﺖ ﺟﺎﻣﻌﻪ ،ﺩﺭ ﻋﯿﻦ
ﺍﺻﻠﯽ ﺍﯾﻦ ﮐﻨﻔﺮﺍﻧﺲ ﺭﺍ ﭼﮕﻮﻧﮕﯽ ﺭﻭﯾﺎﺭﻭﯾﯽ
ﻣﯽﺷﻮﻧﺪ.
ﺣﺎﻝ ﺣﻤﺎﯾﺖ ﺍﺯ ﺍﻫﺪﺍﻑ ﻣﺮﺗﺒﻂ ﺑﺎ ﺗﻮﺳــﻌﻪ
ﺑــﺎ ﺷــﺮﺍﯾﻂ ﺁﺏﻭﻫﻮﺍﯾﯽ ﮔــﺮﻡ ﻭ ﻣﺮﻃﻮﺏ
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﻭ ﺧﻄﺮﺍﺗﯽ ﻧﯿﺰ ﻣﻮﺟﻮﺩ ﺍﺳــﺖ ﮐﻪ ﻫﺮ ﯾﮏ ﻣﺘﻮﺟﻪ ﺳﻼﻣﺖ ﺍﻧﺴﺎﻥ ﻣﯽﮐﻨﻨﺪ.
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 3ﺷﻤﺎﺭﻩ 30
ﺗﺸــﮑﯿﻞ ﺧﻮﺍﻫﻨــﺪ ﺩﺍﺩ .ﺑﺮﻧﺎﻣــﻪ ﻓﻨــﯽ
ﺗﻌـﺪﺍﺩ ﺳـﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺩﺍﺭﺍﯼ ﺑﺮﭼﺴﺐ ﺍﻧﺮﮊﯼ ﺍﺯ ﻣﺮﺯ ﯾﮏ ﻣﯿﻠﯿﻮﻥ ﮔﺬﺷﺖ
ﺑﺮﺝ ﻣﺮﮐﺰﯼ ﻣﺘﻤﺮﮐﺰ ﻣﯽﮐﻨﻨﺪ .ﻣﺴــﺎﺣﺖ
ﻣﺨﺘﻠﻒ ﺍﺳــﺖ ﮐــﻪ ﻣﻮﺿﻮﻋﺎﺗــﯽ ﻣﺎﻧﻨﺪ
ﻃﺒــﻖ ﮔــﺰﺍﺭﺵ ﺁﮊﺍﻧــﺲ ﺣﻔﺎﻇﺖ ﺍﺯ
ﺁﯾﻨﻪﻫﺎﯼ ﻣﺴــﻄﺤﯽ ﮐــﻪ ﺩﺭ ﺍﯾﻦ ﭘﺮﻭﮊﻩ ﺑﻪ
ﮐﻨﺘﺮﻝ ﺭﻃﻮﺑﺖ ،ﻋﻤﻠﮑﺮﺩ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎﯼ
ﻣﺤﯿﻂ ﺯﯾﺴــﺖ ) ،(EPAﺩﺭ ﻣﺎﻩ ﮔﺬﺷﺘﻪ
ﮐﺎﺭ ﮔﺮﻓﺘــﻪ ﻣﯽﺷــﻮﻧﺪ ﺗﻘﺮﯾﺒــﺎ ﺩﺭ ﺣﺪﻭﺩ
ﺗﻌــﺪﺍﺩ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎﯾﯽ ﮐــﻪ ﻣﻮﻓــﻖ ﺑﻪ
) 4000acres (1600haﺍﺳﺖ.
ﺍﺭﺍﺋﻪﺷﺪﻩ ﺑﺮﺍﯼ ﺍﯾﻦ ﮐﻨﻔﺮﺍﻧﺲ ﺩﺭﺑﺮﮔﯿﺮﻧﺪﻩ ﺑﯿﺶ ﺍﺯ ﺳــﯿﺼﺪ ﺳــﺨﻨﺮﺍﻧﯽ ﻭ ﻧﻮﺩ ﺑﺮﻧﺎﻣﻪ
ﺧﻮﺩﮐﻔﺎ ،ﺻﺮﻓﻪﺟﻮﯾــﯽ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﻭ ﺍﻧﺮﮊﯼﻫــﺎﯼ ﻧــﻮ ﺭﺍ ﺗﺤﺖ ﭘﻮﺷــﺶ ﻗﺮﺍﺭ
ﺍﺯ ﺁﯾﻨﻪﻫﺎﯼ ﻣﺴﻄﺢ ﺍﺳﺖ ﮐﻪ ﻧﻮﺭ ﺧﻮﺭﺷﯿﺪ ﺭﺍ ﺭﻭﯼ ﮔﯿﺮﻧــﺪﻩﺍﯼ ﻗﺮﺍﺭﮔﺮﻓﺘــﻪ ﺩﺭ ﺑﺎﻻﯼ
ﺩﺭﯾﺎﻓــﺖ ﺑﺮﭼﺴــﺐ ﺍﻧﺮﮊﯼ ﺍﺯ ﺍﯾــﻦ ﺁﮊﺍﻧﺲ
ﺳــﺎﻝ 2010ﺑﺮﮔﺰﺍﺭ ﺷﻮﺩ .ﺩﺭ ﺣﺎﺷﯿﻪ ﺍﯾﻦ
ﻣﻄﺎﺑﻖ ﺑﺎ ﺩﺳــﺘﻮﺭﺍﻟﻌﻤﻞ ﺑﺎﺯﺩﻩ ﺍﻧﺮﮊﯼ ﮐﻪ
ﮐﻪ ﺷﺎﺧﺺ The Architecture Billing
ﮐﻨﻔﺮﺍﻧــﺲ ،ﻧﻤﺎﯾﺸــﮕﺎﻩ ﺑﯿﻦﺍﻟﻤﻠﻠﯽ ﺗﻬﻮﯾﻪ
ﺁﮊﺍﻧــﺲ ﺣﻔﺎﻇﺖ ﺍﺯ ﻣﺤﯿﻂ ﺯﯾﺴــﺖ ﺁﻥ ﺭﺍ
IndexABIﺍﺯ ﻣﺎﻩ ﺁﮔﻮﺳــﺖ ﺳــﺎﻝ 2008
ﻣﻄﺒﻮﻉ ،ﮔﺮﻣﺎﯾﺶ ﻭ ﺳــﺮﻣﺎﯾﺶ )(AHR
ﺗﻬﯿﻪ ﮐﺮﺩﻩ ﺍﺳــﺖ ﺑﻪ ﻃﻮﺭ ﻣﺴﺘﻘﻞ ﺑﺮﺭﺳﯽ
ﺑﻪ ﺑﯿﺸﺘﺮﯾﻦ ﺣﺪ ﺧﻮﺩ ﺭﺳﯿﺪﻩ ﺍﺳﺖABI .
ﺩﺭ ﺗﺎﺭﯾﺦ ﺑﯿﺴــﺖﻭﭘﻨﺠﻢ ﺗﺎ ﺑﯿﺴﺖﻭﻫﻔﺘﻢ
ﻣﯽﺷــﻮﺩ .ﺑﺮﭼﺴــﺐ ﺍﻧﺮﮊﯼ ﺑــﺮﺍﯼ ﺍﻭﻟﯿﻦ
ﺷــﺎﺧﺺ ﺍﻗﺘﺼﺎﺩﯼ ﻣﺎﻫﺎﻧــﻪ ﻓﻌﺎﻟﯿﺖﻫﺎﯼ
ﮊﺍﻧﻮﯾﻪ ﺑﺮﮔﺰﺍﺭ ﺧﻮﺍﻫﺪ ﺷﺪ.
ﺑﺎﺭ ﺩﺭ ﺳــﺎﻝ 1995ﻣﯿــﻼﺩﯼ ﺑﻪ ﺧﺎﻧﻪﻫﺎ
ﺳﺎﺧﺖﻭﺳــﺎﺯ ﺍﺳﺖ .ﻃﺒﻖ ﺁﻣﺎﺭ ﺍﺭﺍﺋﻪﺷﺪﻩ ﺍﺯ
ﺍﺧﺘﺼــﺎﺹ ﺩﺍﺩﻩ ﺷــﺪ ﻭ ﭘــﺲ ﺍﺯ ﺁﻥ ﺑﻮﺩ
ﺟﺎﻧــﺐ ﺍﻧﺠﻤﻦ ﻣﻌﻤــﺎﺭﺍﻥ ﺁﻣﺮﯾﮑﺎ )،(AIA
ﮐــﻪ ﺑﯿﺶ ﺍﺯ ﺷــﺶﻫﺰﺍﺭﻭﭘﺎﻧﺼﺪ ﺳــﺎﺯﻧﺪﻩ
ﺑﯿﺸﺘﺮﯾﻦ ﺳــﻬﻢ ﺳﺎﺧﺖﻭﺳــﺎﺯ ﻣﺮﺑﻮﻁ ﺑﻪ
ﺩﺭ ﺍﯾﺎﻟﺖﻫﺎﯼ ﻣﺨﺘﻠــﻒ ﺁﻣﺮﯾﮑﺎ ،ﺍﻗﺪﺍﻡ ﺑﻪ
ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﻣﺴﮑﻮﻧﯽ ،ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ
ﺳﺎﺧﺖ ﺧﺎﻧﻪﻫﺎﯾﯽ ﮐﺮﺩﻧﺪ ﮐﻪ ﺑﺎ ﻣﻌﯿﺎﺭﻫﺎﯾﯽ
ﭼﻨﺪﺧﺎﻧﻮﺍﺭ ﻭ ﺳــﺎﺯﻣﺎﻧﯽ ﺑﻮﺩﻩ ﺍﺳﺖ .ﺩﮐﺘﺮ
ﺍﻧﺠﻤﻦ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺳﺒﺰ ﺍﯾﺎﻻﺕ ﻣﺘﺤﺪﻩ
ﺗﻌﯿﯿﻦﺷــﺪﻩ ﺩﺭ ﻃﺮﺡ ENERY STAR
ﮐﺮﻣﯿﺖ ﺑﯿﮑﺮ ﯾﮑﯽ ﺍﺯ ﺍﺳــﺘﺎﺩﻫﺎﯼ ﺑﺮﺟﺴﺘﻪ
ﺩﺭ ﺷﻬﺮ ﺷﯿﮑﺎﮔﻮ ﻣﻨﺘﺸﺮ ﺷﺪﻩ ،ﺣﺎﮐﯽ ﺍﺯ ﺁﻥ
ﻣﻄﺎﺑﻘﺖ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ.
ﺍﻗﺘﺼــﺎﺩ ﺩﺭ ﺍﯾﻦ ﺑﺎﺭﻩ ﻣﯽﮔﻮﯾــﺪ” :ﺍﯾﻦ ﺧﺒﺮ
ﺗﺎﺭﯾﺦ ﺑﯿﺴﺖﻭﺳﻮﻡ ﺗﺎ ﺑﯿﺴﺖﻭﻫﻔﺘﻢ ﮊﺍﻧﻮﯾﻪ
ﻃﺮﺍﺣـﯽ ﭘﺎﯾـﺪﺍﺭ ﺭﻭﻧﺪﯼ ﻣـﺪﺍﻭﻡ ﻭ ﺑﺪﻭﻥ ﺗﻮﻗﻒ ﮔــﺰﺍﺭﺵ ﺟﺪﯾــﺪﯼ ﮐﻪ ﺍﺧﯿﺮﺍ ﺗﻮﺳــﻂ
ﺍﺳﺖ ﮐﻪ ﻃﺮﺍﺣﯽ ﭘﺎﯾﺪﺍﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎ ﺗﻨﻬﺎ
ﻣﯽﺗﻮﺍﻧﺪ ﻧﺸــﺎﻧﻪ ﺯﻭﺩﻫﻨﮕﺎﻣــﯽ ﺑﺮﺍﯼ ﺑﻬﺒﻮﺩ
ﻣﺒﺘﻨﯽ ﺑﺮ ﺷــﯿﻮﻩ ﻃﺮﺍﺣﯽ ﻭ ﺳﺎﺧﺖﻭﺳﺎﺯ
ﺍﻗـﺪﺍﻡ ﺑـﺮﺍﯼ ﺍﺟـﺮﺍﯼ ﭘـﺮﻭﮊﻩ ﺑﺮﺝ ﺧﻮﺭﺷﯿﺪﯼ
ﭘﺎﯾﺎﻥ ﻣﺮﺍﺣﻞ ﻃﺮﺍﺣﯽ ﻭ ﺍﺟﺮﺍﯼ ﺳﺎﺧﺘﻤﺎﻥ
ﺩﭘﺎﺭﺗﻤــﺎﻥ ﺩﺍﺧﻠــﯽ ﺍﯾــﺎﻻﺕ ﻣﺘﺤﺪﻩ
ﺍﺩﺍﻣﻪ ﭘﯿﺪﺍ ﻣﯽﮐﻨﺪ .ﺑﺮ ﺍﺳﺎﺱ ﺍﯾﻦ ﮔﺰﺍﺭﺵ،
) (USDIﻭ ﮐﻤﯿﺴــﯿﻮﻥ ﺍﻧﺮﮊﯼ ﮐﺎﻟﯿﻔﺮﻧﯿﺎ
ﭘﺎﯾﺪﺍﺭ ﺑﻮﺩﻥ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎ ﻓﺮﺁﯾﻨﺪﯼ ﺭﻭ ﺑﻪ
) (CECﻃــﺮﺡ ﻧﻬﺎﯾﯽ ﺑــﺮﺍﯼ ﻭﺭﻭﺩ ﺑﻪ ﻓﺎﺯ
ﺭﺷﺪ ﻭ ﺩﺭﺍﺯﻣﺪﺕ ﺍﺳﺖ ﮐﻪ ﻫﯿﭻﮔﺎﻩ ﻣﺘﻮﻗﻒ
ﺍﺟﺮﺍﯾــﯽ ﭘــﺮﻭﮊﻩ Ivanpahﺭﺍ ﺑﺮﺍﯼ ﺗﻮﻟﯿﺪ
ﻧﻤﯽﺷــﻮﺩ .ﺩﺭ ﺍﯾﻦ ﮔﺰﺍﺭﺵ ،ﺑﯿﺴﺖﻭﭘﻨﺞ
ﺑﺮﻕ ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺍﻧﺮﮊﯼ ﺧﻮﺭﺷﯿﺪﯼ ﺑﻪ
ﺳــﺎﺧﺘﻤﺎﻥ ﺩﺭ ﺷﻬﺮ ﺷﯿﮑﺎﮔﻮ ﮐﻪ ﻣﻮﻓﻖ ﺑﻪ
ﺍﺗﻤﺎﻡ ﺭﺳــﺎﻧﺪﻧﺪ .ﻣﺤﻞ ﺍﺟﺮﺍﯼ ﺍﯾﻦ ﭘﺮﻭﮊﻩ،
ﺩﺭﯾﺎﻓــﺖ ﮔﻮﺍﻫﯽ LEEDﺷــﺪﻩ ﺑﻮﺩﻧﺪ ﺑﻪ
ﺳﺎﯾﺘﯽ ﻭﺍﻗﻊ ﺩﺭ ﺩﺭﻩ Ivanpahﺩﺭ ﺟﻨﻮﺏ
ﻋﻨــﻮﺍﻥ ﻧﻤﻮﻧﻪ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷــﺪ .ﺗﻤﺎﻡ
ﺍﯾﺎﻟﺖ ﮐﺎﻟﯿﻔﺮﻧﯿﺎﺳــﺖ ﻭ ﻗﺮﺍﺭ ﺍﺳــﺖ ﺩﺭ ﺁﻥ
ﺁﻥﻫــﺎ ﺍﺯ ﺩﯾﺪﮔﺎﻩ ﻭﺿﻌﯿــﺖ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ
ﺍﺯ ﻓﻦﺁﻭﺭﯼ ﺑﺮﺝ ﺧﻮﺭﺷــﯿﺪﯼ ﺑﺮﺍﯼ ﺗﻮﻟﯿﺪ
ﺳﺎﺧﺖ ﻭ ﻋﻤﻠﯿﺎﺕ ﺗﺎﺳﯿﺴﺎﺕ K12ﺩﺳﺖ
ﻭ ﺩﯾﮕﺮ ﻋﻮﺍﻣﻠﯽ ﻋﻤﮑﻠﺮﺩﯼ ﺑﺮﺭﺳــﯽ ﺷﺪ.
ﺑﺮﻕ ﺍﺳــﺘﻔﺎﺩﻩ ﺷــﻮﺩ .ﻻﺯﻡ ﺑﻪ ﺫﮐﺮ ﺍﺳﺖ
ﯾﺎﻓﺘﻪ ﺧﻮﺍﻫﺪ ﺷــﺪ .ﻣﺠﺮﯾﺎﻥ ﺍﯾﻦ ﮐﻨﻔﺮﺍﻧﺲ
ﻻﺯﻡ ﺑﻪ ﺫﮐﺮ ﺍﺳــﺖ ﺍﯾــﻦ ﺍﻭﻟﯿﻦ ﺑﺎﺭﯼ ﺑﻮﺩ
ﮐــﻪ ﺍﯾﻦ ﻧﯿــﺮﻭﮔﺎﻩ ﻗﺮﺍﺭ ﺍﺳــﺖ 400MW
ﮐﺎﺭﺷﻨﺎﺳــﺎﻥ ﻋﻠﻮﻡ ﺻﻮﺕ ﺷﻨﺎﺳــﯽ ،ﻧﻮﺭ،
ﮐﻪ ﺟﺰﯾﯿﺎﺕ ﻋﻤﻠﮑﺮﺩ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎﯾﯽ ﮐﻪ
ﺑــﺮﻕ ﻣﻮﺭﺩ ﻧﯿــﺎﺯ ﺍﯾﻦ ﻣﻨﻄﻘــﻪ ﺭﺍ ﺻﺮﻓﺎ ﺑﺎ
ﺗﻬﻮﯾﻪ ﻣﻄﺒــﻮﻉ ،ﮐﻨﺘﺮﻝﻫﺎﯼ ﺳﯿﺴــﺘﻤﯽ،
ﻣﻮﻓﻖ ﺑﻪ ﺩﺭﯾﺎﻓﺖ ﮔﻮﺍﻫﯽ LEEDﺷﺪﻩﺍﻧﺪ
ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺍﻧﺮﮊﯼ ﺧﻮﺭﺷﯿﺪﯼ ﺗﺎﻣﯿﻦ ﮐﻨﺪ.
ﮐﺎﺭﺍﻣــﺪﯼ ﺍﻧــﺮﮊﯼ ﻭ ﻋﻤﻠﯿــﺎﺕ ﻭ ﺗﻌﻤﯿﺮﺍﺕ
ﺍﺭﺯﯾﺎﺑﯽ ﺟﺰﯾﯽ ﻭ ﺩﻗﯿﻖ ﻣﯽﺷﻮﺩ.
ﻓﻦﺁﻭﺭﯼ ﺑﺮﺝ ﺧﻮﺭﺷﯿﺪﯼ ﺷﺎﻣﻞ ﺣﻮﺯﻩﺍﯼ
ﺧﻮﺍﻫﻨﺪ ﺑﻮﺩ.
ﺳﺎﺧﺘﻤﺎﻥ ﻧﯿﺴﺖ ،ﺑﻠﮑﻪ ﺍﯾﻦ ﺭﻭﻧﺪ ﭘﺲ ﺍﺯ
ﺗﻠﻔﻦ88739880-2:
ﺍﻧﺠﻤــﻦ ASHRAEﺩﺭ ﺗﺎﺭﯾــﺦ 2-1 ﻣــﺎﺭﺱ ﺩﺭ ﺁﺗﻼﻧﺘﺎ ﮐﻨﻔﺮﺍﻧﺴــﯽ ﺑــﺎ ﻣﻮﺿﻮﻉ ﺗﺎﺳﯿﺴﺎﺕ ﻣﺪﺭﺳﻪﺍﯼ K-12ﺑﺎ ﻋﻤﻠﮑﺮﺩ ﺑﺎﻻ ﺑﺮﮔــﺰﺍﺭ ﺧﻮﺍﻫﺪ ﮐﺮﺩ .ﻣﺤــﻮﺭ ﺍﯾﻦ ﮐﻨﻔﺮﺍﻧﺲ ﺭﻭﯾﮑﺮﺩ ﺗﻠﻔﯿﻘﯽ ﭘﯿﺮﻭﯼ ﺍﺯ ﺭﻣﺰﻫﺎ ﻭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩﻫﺎ ﺧﻮﺍﻫﺪ ﺑﻮﺩ ﻭ ﺩﺭ ﻋﯿﻦ ﺣﺎﻝ ﺑﻪ ﺭﺍﻫﮑﺎﺭﻫﺎﯾﯽ ﺑﺮﺍﯼ ﮐﺎﺭﺍﯾﯽ ﺑﺎﻻ ﻭ ﺻﺮﻓﻪ ﺍﻗﺘﺼﺎﺩﯼ ﻃﺮﺍﺣﯽ،
ﺗﻠﻔﻦ55401278 :
Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﮐﻨﻔﺮﺍﻧـﺲ ASHRAEﺑﺎ ﻣﻮﺿﻮﻉ ﺗﺎﺳﯿﺴﺎﺕ ﻣﺪﺭﺳﻪ
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺷﺮﺍﯾﻂ ﺩﺭ ﻋﺮﺻﻪ ﺳﺎﺧﺖﻭﺳﺎﺯ ﺑﺎﺷﺪ“.
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺍﻧﺮﮊﯼ ،ﻣﯿــﺰﺍﻥ ﻣﺼﺮﻑ ﺍﻧــﺮﮊﯼ ﻫﺮ ﺧﺎﻧﻪ
ﮔﺰﺍﺭﺵﻫﺎﯼ ﺭﺳﯿﺪﻩ ﺣﺎﮐﯽ ﺍﺯ ﺁﻥ ﺍﺳﺖ
ﻣﯽﺩﻫﻨــﺪ .ﺍﯾﻦ ﮐﻨﻔﺮﺍﻧﺲ ﻗﺮﺍﺭ ﺍﺳــﺖ ﺩﺭ
ﺑﻪ ﺫﮐﺮ ﺍﺳــﺖ ﮐﻪ ﺑﺮﺍﯼ ﺩﺭﯾﺎﻓﺖ ﺑﺮﭼﺴﺐ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺷﺪﻩﺍﻧﺪ ﺍﺯ ﻣﺮﺯ ﯾﮏ ﻣﯿﻠﯿﻮﻥ ﮔﺬﺷﺖ .ﻻﺯﻡ
ﺍﻓﺰﺍﯾﺶ ﻓﻌﺎﻟﯿﺖﻫﺎﯼ ﺳﺎﺧﺖﻭﺳـﺎﺯ ﺩﺭ ﺳﻄﺢ ﺟﻬﺎﻥ
ﺻﻔﺤﻪ / 4ﺷﻤﺎﺭﻩ 30
ﻋﻠﻤﻰ
ﻛﻤﭙﺮﺳﻮﺭﻫﺎﻯ ﺩﻭﺍﺭ ﺗﺮﺍﻛﻤﻰ ﺑﺎ ﻛﻴﻔﻴﺖ ﺑﺎﻻ
ﺩﻭﺍﺭ ﻓﻦﺁﻭﺭﯼ ﻧﺴــﺒﺘﺎ ﺟﺪﯾﺪﯼ ﻫﺴﺘﻨﺪ .ﻧﺨﺴﺘﯿﻦ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﻣﻘﺪﻣﻪ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ﭼﯿﺴــﺖ؟ ﺑــﺮ ﺍﺳــﺎﺱ ﮐﺘــﺎﺏ
ﺑﻪ ﺳــﺎﻝ 1905ﺑﺮﻣﯽﮔــﺮﺩﺩ .ﻟﺌﻮﻥ ﮐﺮﻭ ،ﻣﻬﻨﺪﺱ ﻓﺮﺍﻧﺴــﻮﯼ،
ﺭﺍﻫﻨﻤــﺎﯼ ﺗﺠﻬﯿــﺰﺍﺕ ﻭ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾــﻪ ﻣﻄﺒــﻮﻉ
ﻧﺨﺴــﺘﯿﻦ ﻃﺮﺡ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ﺭﺍ ﭘﺪﯾﺪ ﺁﻭﺭﺩ ﮐــﻪ ﻓﺮﺍﺗﺮ ﺍﺯ ﺯﻣﺎﻥ
،ASHRAE 2004) ASHRAEﺑﺨﺶ ،(34ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ
ﺧــﻮﺩﺵ ﺑﻮﺩ؛ ﻭﻟﯽ ﺗﺎ ﺁﻏﺎﺯ ﺩﻫﻪ ،1970ﭘﯿﺸــﺮﻓﺖﻫﺎﯼ ﻓﻦﺁﻭﺭﯼ
ﺩﻭﺍﺭ ﻣﺎﺷﯿﻦﻫﺎﯾﯽ ﺑﺎ ﺣﺮﮐﺖ ﺩﻭﺭﺍﻧﯽ ﻭ ﺟﺎﺑﻪﺟﺎﯾﯽ ﻣﺜﺒﺖﺍﻧﺪ ﮐﻪ ﺑﺎ
ﺑــﺮﺍﯼ ﺍﻣﮑﺎﻥ ﻋﻤﻠــﯽ ﭼﻨﯿﻦ ﻃﺮﺣﯽ ﻣﯿﺴــﺮ ﻧﺒﻮﺩ .ﭘﯿﺸــﺮﻓﺖﻫﺎ
ﺩﻭ ﻋﻀــﻮ ﺩﺍﯾﺮﻩﺍﯼ ﺩﻭﺍﺭ ﻭ ﺩﺭﮔﯿﺮ ،ﻋﻤﻞ ﺗﺮﺍﮐﻢ ﺭﺍ ﺍﻧﺠﺎﻡ ﻣﯽﺩﻫﻨﺪ.
ﺑﻪﺧﺼــﻮﺹ ﺩﺭ ﮊﺍﭘﻦ ﻭ ﺍﯾــﺎﻻﺕ ﻣﺘﺤﺪﻩ ﺍﺩﺍﻣﻪ ﯾﺎﻓﺘــﻪ ﻭ ﺍﺯ ﻣﯿﺎﻥ
ﺧﻮﺍﻧﻨﺪﻩ ﻭﻗﺘﯽ ﻣﻔﻬﻮﻡ ﺳﺎﺩﻩ ﭼﮕﻮﻧﮕﯽ ﻋﻤﻠﮑﺮﺩ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﺭﺍ
ﺩﻫﻪ 1980ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺳﺮﻣﺎﯾﺸﯽ ﻭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ،ﮔﺴﺘﺮﺵ
ﺩﺭﮎ ﮐﻨﺪ ،ﻣﻨﻈﻮﺭ ASHRAEﺭﺍ ﺑﻬﺘﺮ ﺧﻮﺍﻫﺪ ﻓﻬﻤﯿﺪ؛ ﻭﻟﯽ ﻓﻬﻢ
ﯾﺎﻓﺖ .ﺍﻣﺮﻭﺯ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺩﺭ ﺑﺴﯿﺎﺭﯼ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺧﺎﻧﮕﯽ
ﭼﮕﻮﻧﮕﯽ ﻋﻤﻞ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ﺑﻪ ﺍﯾﻦ ﺳﺎﺩﮔﯽ ﻧﯿﺴﺖ .ﻫﺪﻑ ﺍﺯ
ﻭ ﺗﺠﺎﺭﯼ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﻧﺪ.
ﺍﯾﻦ ﻣﻘﺎﻟﻪ ،ﺗﻮﺿﯿﺢ ﺍﯾﻦ ﻋﻤﻞ ،ﺍﺳﺎﺱ ﻋﻤﻠﮑﺮﺩ ﻭ ﮐﺎﺭﺑﺮﺩ ﺁﻥ ﺍﺳﺖ.
ﺑﺮﺧــﻼﻑ ﺁﻥ ،ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﭘﺮﻭﺍﻧــﻪﺍﯼ ،ﺗﺎﺭﯾﺨﯽ ﻃﻮﻻﻧﯽ
ﻫﻤﭽﻨﯿــﻦ ﺑﻪ ﺑﺤﺚ ﭘﯿﺮﺍﻣﻮﻥ ﻋﻤﻠﮑﺮﺩ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ،ﮐﺎﺭﺍﯾﯽ ﻭ
ﺩﺍﺷــﺘﻪ؛ ﻭﻟﯽ ﺗﻄﺒﯿــﻖ ﻋﻤﻠﯽ ﺁﻥﻫﺎ ﺑــﺎ ﮐﺎﺭﺑﺮﺩ ﺗﻬﻮﯾــﻪ ﻣﻄﺒﻮﻉ،
ﭘﺎﯾﺎﯾﯽ ﺁﻥ ﻣﯽﭘﺮﺩﺍﺯﺩ.
ﺍﯾﻦﭼﻨﯿﻦ ﻃﻮﻻﻧﯽ ﻧﯿﺴــﺖ .ﻧﺨﺴــﺘﯿﻦ ﻃﺮﺡ ﮐﻤﭙﺮﺳﻮﺭ ﭘﺮﻭﺍﻧﻪﺍﯼ
ASHRAEﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺭﺍ ،ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯾﯽ ﺑــﺎ
ﺑﻪ 1878ﺑﺮﮔﺸــﺘﻪ؛ ﻭﻟﯽ ﻧﺨﺴــﺘﯿﻦ ﮐﻤﭙﺮﺳــﻮﺭ ﺑﺎ ﺩﻭ ﭘﺮﻭﺍﻧﻪ ،ﺗﺎ
ﺟﺎﺑﻪﺟﺎﯾﯽ ﻣﺜﺒﺖ ﻭ ﺣﺮﮐــﺖ ﺩﻭﺭﺍﻧﯽ ﻃﺒﻘﻪ ﺑﻨﺪﯼ ﻣﯽﮐﻨﺪ؛ ﺍﻟﺒﺘﻪ
ﺳــﺎﻝ 1935ﭘﺪﯾﺪﺍﺭ ﻧﺸﺪ .ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﭘﺮﻭﺍﻧﻪﺍﯼ ،ﻧﺨﺴﺖ ﺩﺭ
ﺑﺮﺍﯼ ﻣﻘﺎﺻﺪ ﻋﻤﻠﯽ ،ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﻣﻌﻤﻮﻻ ﺟﺰﻭ ﻣﺎﺷﯿﻦﻫﺎﯾﯽ ﭘﺮﻭﺍﻧﻪ ﺩﻭﺗﺎﯾﯽ ،ﭘﺮﻭﺍﻧﻪ ﺗﮏ ،ﭘﺮﻩ ﮔﺮﺩﻧﺪﻩ ﻭ ﭘﯿﺴــﺘﻮﻥ ﻏﻠﺘﺎﻥ ﺍﺳﺖ. ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﭼﺮﺧﻨﺪﻩ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﻣﯽﺷــﻮﻧﺪ ﮐﻪ ﺷــﺎﻣﻞ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯾﯽ ﺑﺎ ﻃﺒﻘﻪﺑﻨــﺪﯼ ASHRAEﻣﯽﺗﻮﺍﻧــﺪ ﺍﺯ ﻧﻈﺮ ﻓﻨﯽ ﺗﻮﺳــﻌﻪ ﯾﺎﺑﺪ؛ ﻭﻟﯽ ﺍﯾﻦ ﺗﻤﺎﯾــﺰ ﺗﺎﺛﯿﺮﯼ ﺑﺮ ﺑﺎﺯﺍﺭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﻧﺨﻮﺍﻫﺪ ﺩﺍﺷــﺖ. ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﭼﺮﺧﻨﺪﻩ ﻭ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯾﯽ ﺑﺎ ﭘﺮﻭﺍﻧﻪ ﺩﻭﺗﺎﯾﯽ ﻭ ﭼﺮﺧﻨﺪﻩ ،ﻫﺮ ﺩﻭ ﺑﺎﻗﯽ ﻣﺎﻧﺪﻩ ﻭ ﻓﻦﺁﻭﺭﯼﻫﺎﯼ ﺟﺎﺑﻪﺟﺎﯾﯽ ﻣﺜﺒﺖ ﺩﺭ ﺍﻣﻮﺭ ﺗﺠﺎﺭﯼ ﻣﺎﻧﻨﺪ ﭼﯿﻠﺮﻫﺎﯼ ﺁﺑﯽ ﺧﻨﮏﮐﻨﻨﺪﻩ ﻫﻮﺍ ،ﮐﺎﺭﺑﺮﺩ ﺩﺍﺭﻧﺪ. ﺣﺮﮐــﺖ ﺩﻭﺍﺭ ﺍﺟــﺰﺍﯼ ﻣﺘﺮﺍﮐﻢﮐﻨﻨﺪﻩ ﺁﻥﻫﺎ ،ﻫــﺮ ﺩﻭ ﺭﺍ ﺍﺯ ﺣﺮﮐﺖ ﺧﻄﯽ ﭘﯿﺴــﺘﻮﻥﻫﺎ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﻣﺘﻨﺎﻭﺏ ﻭ ﺣﺮﮐﺖ ﭼﺮﺧﺸﯽ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﮔﺮﯾﺰﺍﺯﻣﺮﮐﺰ ،ﻣﺘﻤﺎﯾﺰ ﻣﯽﮐﻨﺪ.
ﻛﺘﺎﺏ
ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺍﺳﺎﺱ ﻋﻤﻠﮑﺮﺩ ﻫﻨﺪﺳﻪ ﯾﮏ ﺩﻭﺭﺍﻥ ﺑﺮ ﺍﺳــﺎﺱ ﺗﻌﺮﯾــﻒ ،ﺩﻭﺭﺍﻥ ﮔﺮﺩﺵ ﯾﺎ ﭼﺮﺧﺸــﯽ ﺑﻪ ﺩﻭﺭ ﯾﮏ ﻣﺮﮐﺰ ﺍﺳــﺖ .ﺩﻭﺭﺍﻥ ،ﯾﮏ ﻣﺎﺭﭘﯿﭻ ﺑﻪﺣﺴﺎﺏ ﻣﯽﺁﯾﺪ .ﻣﺎﺭﭘﯿﭻ ﯾﮏ ﻣﻨﺤﻨﯽ ﺩﺍﯾﺮﻩﺍﯼ ﺍﺳــﺖ .ﻣﮑﺎﻥ ﻫﻨﺪﺳــﯽ ﻧﻘﻄﻪﺍﯼ ﮐﻪ ﺑﺎ ﺍﻓﺰﺍﯾﺶ ﺷــﻌﺎﻉ ،ﺣﻮﻝ ﯾﮏ ﻣﺮﮐﺰ ﺛﺎﺑﺖ ﺣﺮﮐﺖ ﻣﯽﮐﻨــﺪ .ﻣﺎﺭﭘﯿﭻ ﻣﻤﮑﻦ ﺍﺳــﺖ ﻫﻤﺎﻥﻃﻮﺭ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ ) (1ﻧﺸــﺎﻥ ﺩﺍﺩﻩ ﺷــﺪﻩ ،ﯾﮏ ﯾﺎ ﭼﻨﺪ ﺩﻭﺭ ﺩﺍﺷﺘﻪ ﺑﺎﺷــﺪ .ﺍﻧﻮﺍﻉ ﻣﺨﺘﻠﻔﯽ ﺍﺯ ﻣﺎﺭﭘﯿﭻﻫﺎ ﻭﺟﻮﺩ ﺩﺍﺭﺩ ﻣﺎﺭﭘﯿﭻ ﭘﺎﯾﻪ ،ﻣﺎﺭﭘﯿﭻ ﺍﺭﺷﻤﯿﺪﺱ ﺍﺳﺖ ﮐﻪ ﺑﺮ ﺍﺳﺎﺱ ﻣﻌﺎﺩﻟﻪ ﺳﺎﺩﻩ
ﻫﺮﭼﻨﺪ ﺍﯾﺪﻩ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﺟﺪﯾﺪ ﻧﯿﺴﺖ ،ﺧﻮﺩ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
ﻣﻄﺒﻮﻉ ﻧﺸﺪﻧﺪ.
ﮐﻪ ﻫﺮ ﯾﮏ ﺑﺮ ﺍﺳــﺎﺱ ﺗﻨﻮﻉ ﻣﻌﺎﺩﻟﻪ ﭘﺎﯾﻪ ﺭﯾﺎﺿﯽ ﺗﻌﺮﯾﻒ ﻣﯽﺷﻮﻧﺪ.
ﺗﺎﺭﯾﺨﭽﻪ ﻭ ﺗﻮﺳﻌﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ«
ﻣﻮﺍﺭﺩ ﺻﻨﻌﺘﯽ ﺍﺳــﺘﻔﺎﺩﻩ ﺷﺪﻩ ﻭ ﺗﺎ ﭘﺎﯾﺎﻥ ﻗﺮﻥ ﺑﯿﺴﺘﻢ ،ﻭﺍﺭﺩ ﺗﻬﻮﯾﻪ
@ a = rﺍﺳــﺖ ﮐﻪ rﺷــﻌﺎﻉ ﺍﺯ ﻣﺮﮐﺰﯼ ﺛﺎﺑﺖ a ،ﻣﻘﺪﺍﺭﯼ ﺛﺎﺑﺖ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 5ﺷﻤﺎﺭﻩ 30
ﻭ @ ﺯﺍﻭﯾﻪ )ﺩﺭ ﻣﺨﺘﺼﺎﺕ ﻗﻄﺒﯽ( ﺍﺳــﺖ .ﺩﯾﮕﺮ ﺣﺎﻟﺖﻫﺎ ﺷﺎﻣﻞ
ﺍﯾﻦ ﺷــﮑﻞ ﺑﻪ ﺍﺟﺰﺍﯼ ﻣﺘﻘﺎﺑﻞ ﺍﻣــﮑﺎﻥ ﺩﺭﻫﻢ ﻓﺮﻭﺭﻓﺘﮕﯽ ﺭﺍ ﺑﻪ
ﻣﺎﺭﭘﯿﭻﻫــﺎﯼ ﻫﯿﭙﺮﺑﻮﻟﯿــﮏ )ﻫﺬﻟﻮﻟــﯽ( ،ﭘﺎﺭﺍﺑﻮﻟﯿﮏ )ﺳــﻬﻤﯽ(،
ﮔﻮﻧــﻪﺍﯼ ﻣﯽﺩﻫﺪ ﮐﻪ ﺳــﻄﻮﺡ ﺣﺎﻣﻞ ،ﺩﺭ ﺟﻬــﺖ ﻣﻘﺎﺑﻞ ﯾﮑﺪﯾﮕﺮ
ﻟﮕﺎﺭﯾﺘﻤﯽ ﻭ ﺗﻮﺩﺭﺗﻮ ﻫﺴﺘﻨﺪ.
ﻗﺮﺍﺭ ﮔﯿﺮﻧﺪ ،ﻧﻪ ﺑﺮ ﺭﻭﯼ ﻫﻢ )ﺑﻪ ﺷــﮑﻞ ﺩﻧﺪﺍﻧﻪﺍﯼ( .ﺍﯾﻦ ﺍﻣﺮ ﺑﺎﻋﺚ
ﺍﮔﺮ ﺑﻌﺪ ﺳــﻮﻣﯽ ﺑﻪ ﻣﺎﺭﭘﯿﭻ ﺳــﺎﺩﻩ ﺑﯿﻔﺰﺍﯾﯿﺪ ،ﻧﺘﯿﺠﻪ ،ﺻﻔﺤﻪ
ﮐﺎﻫﺶ ﺍﺻﻄﮑﺎﮎ ﻭ ﺳــﺎﯾﺶ ﻭ ﭘﺪﯾﺪ ﺁﻣﺪﻥ ﺳــﺮﻋﺖ ﺯﺍﻭﯾﻪﺍﯼ ﺩﺭ
ﻣﺎﺭﭘﯿﭽﯽ ﺷﺒﯿﻪ ﻧﻮﺍﺭ ﮐﺎﻏﺬﯼ ﺟﻤﻊﺷﺪﻩ ﺍﺳﺖ .ﻧﺴﺨﻪﻫﺎﯼ ﻗﺪﯾﻤﯽ
ﻫﻨــﮕﺎﻡ ﻓﺮﻭﺭﻓﺘــﻦ ﻗﻄﻌﺎﺕ ﺩﺭ ﯾﮑﺪﯾﮕﺮ ﻣﯽﺷــﻮﺩ .ﺍﯾﻦ ﻫﻨﺪﺳــﻪ
ﮐﻪ ﺑﺮ ﺭﻭﯼ ﺻﻔﺤﺎﺕ ﭼﻮﺑﯽ ﻧﻮﺷﺘﻪ ﺷﺪﻩ ﻭ ﺑﺮﺍﯼ ﻧﮕﻬﺪﺍﺭﯼ ﺑﻪ ﺩﻭﺭ
ﭘﯿﭽﯿــﺪﻩ ﺩﻭﺭﺍﻥ ﻓﺮﻭﺭﻓﺘﻪ ،ﺑﺎﻋﺚ ﭘﺪﯾﺪ ﺁﻣــﺪﻥ ﻋﻤﻞ ﻏﻠﺘﯿﺪﻥ ﺩﺭ
ﻫﻢ ﭘﯿﭽﯿﺪﻩ ﻣﯽﺷﺪﻧﺪ ،ﺭﯾﺸﻪ ﺍﺻﻠﯽ ﻭﺍﮊﻩ ﺩﻭﺍﺭ ﺍﺳﺖ.
ﻧﻘﺎﻁ ﺗﻤﺎﺳﯽ ﻭ ﮐﺎﻫﺶ ﻟﻐﺰﺵ ﻣﯽﺷﻮﺩ.
ﺣﺎﻟﺖ ﺧــﺎﺹ ﻣﻮﺭﺩ ﺍﺳــﺘﻔﺎﺩﻩ ﺩﺭ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ،ﻣﺎﺭﭘﯿﭻ ﺗﻮﺩﺭﺗﻮ ﺍﺳــﺖ ،ﺗﺼﻮﯾﺮ ) .(2ﻣﺎﺭﭘﯿﭻ ﺗﻮﺩﺭﺗﻮ ،ﻣﺎﺭﭘﯿﭽﯽ ﺑﺎ ﺷــﻌﺎﻉ ﻣﺘﻐﯿﺮ ﺍﺳــﺖ ﮐﻪ ﺑﺮ ﭘﺎﯾﻪ ﯾﮏ ﺩﺍﯾــﺮﻩ ﻣﺮﮐﺰﯼ ﺑﺮ ﻣﺤﻮﺭﯼ ﺛﺎﺑﺖ ﻗﺮﺍﺭ ﺩﺍﺭﺩ .ﻣﻨﺤﻨﯽ ﺭﺍ ﻣﯽﺗﻮﺍﻥ ﺑﻪ ﺻﻮﺭﺕ ﻧﻘﻄﻪ ﭘﺎﯾﺎﻧﯽ ﻧﻮﺍﺭﯼ ﮐﻪ ﻣﺤﮑﻢ ﺍﺯ ﯾﮏ ﺍﺳﺘﻮﺍﻧﻪ ﮐﺸﯿﺪﻩﺷﺪﻩ ،ﺩﺭﻧﻈﺮ ﮔﺮﻓﺖ.
ﻣﺤﻞ ﺩﻭﺭﺍﻥ ﺩﻭﺭﺍﻥ ﺟﺰﻭ ﺍﺻﻠﯽ ﺗﺮﺍﮐﻢ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺭﺍﻧﯽ ﺍﺳﺖ .ﺑﻪ ﻃﻮﺭ ﻣﻔﻬﻮﻣﯽ ،ﻧﻮﺍﺭ ﻓﻠﺰﯼ ﻣﺎﺷﯿﻦﺷــﺪﻩﺍﯼ ﺑﻪ ﺷﮑﻞ ﻣﺎﺭﭘﯿﭻ ،ﭘﯿﭽﯿﺪﻩ ﺑﻮﺩﻩ ﻭ ﺑﺮ ﻟﺒﻪﺍﯼ ﺑﻪ ﻭﺳــﯿﻠﻪ ﭘﺎﯾﻪ ﺻﻔﺤﻪﺍﯼ ﻣﺤﮑﻤﯽ ﺑﺴــﺘﻪ ﺷﺪﻩ ﺍﺳــﺖ .ﻣﺤﻞ ﺩﻭﺭﺍﻥ ﺍﺯ ﺩﻭ ﺩﻭﺍﺭ ﺑﺎ ﻫﻨﺪﺳﻪ ﻫﻤﺎﻧﻨﺪ ﺗﺸﮑﯿﻞ ﺷﺪﻩ ﺍﺳــﺖ .ﯾﮑﯽ ﺍﺯ ﺩﻭﺍﺭﻫﺎ ﺑﻪ ﺻــﻮﺭﺕ ﻭﺍﺭﻭﻧﻪ ﺑﺎ ﭼﺮﺧﺶ 180ﺩﺭﺟﻪ ﺑﻮﺩﻩ ﻭ ﻫﻤﺎﻥﻃﻮﺭ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ ) (3ﻧﺸﺎﻥ ﺩﺍﺩﻩ ﺷﺪﻩ ،ﻭﺍﺭﺩ ﺩﻭﺍﺭ ﺩﻭ ﻣﯽﺷﻮﺩ.
ﺩﻭﺭﺍﻧﯽ ﺣﺮﮐــﺖ ﻣﯽﺩﻫﺪ .ﯾﮏ ﻣﻔﺼﻞ ﺧﺎﺹ ﮐﻪ ﻣﻔﺼﻞ ﺍﻭﻟﺪﻫﺎﻡ
ﭘﺎﯾﻪ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻣﯽﺩﺍﺭﺩ .ﻣﻮﺗﻮﺭ ﻣﺤﻮﺭﯼ ﺧﺎﺭﺝ ﻣﺮﮐﺰﯼ ،ﺩﻭﺍﺭ ﭘﺎﯾﯿﻨﯽ ﺭﺍ ﺩﺭ ﺍﻟﮕﻮﯼ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺩﺭ ﺍﻏﻠﺐ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ،ﺳﺎﺧﺘﺎﺭ ﺩﻭﺍﺭ ﻓﻮﻗﺎﻧﯽ ﺭﺍ ﻧﮕﺎﻩ
ﺗﺼﻮﯾﺮ ) (1ﯾﮏ ﻣﺎﺭﭘﯿﭻ ﺳﺎﺩﻩ
ﺗﻠﻔﻦ55401278 :
ﺩﻭﺭﺍﻥ
ﺷﻌﺎﻉ ﻣﺘﻐﯿﺮ
ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ
ﺩﺍﯾﺮﻩ ﭘﺎﯾﻪ
ﺗﺼﻮﯾﺮ ) (2ﺷﻌﺎﻉ ﻣﺎﺭﭘﯿﭽﯽ ﺗﻮﺩﺭﺗﻮ ﮐﻪ ﺍﺯ ﻣﺤﯿﻂ ﯾﮏ ﺩﺍﯾﺮﻩ ﻧﺎﺷﯽ ﺷﺪﻩ ﺍﺳﺖ. ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﺼﻮﯾﺮ ) (3ﻣﺤﯿﻂ ﺩﻭﺍﺭ ﮐﻪ ﺍﺯ ﺩﻭ ﺩﻭﺍﺭ ﺗﺸﮑﯿﻞ ﺷﺪﻩ ﺍﺳﺖ .ﯾﮑﯽ ﺍﺯ ﺁﻥﻫﺎ ﻣﻌﮑﻮﺱ ﺷﺪﻩ ﻭ 180ﺩﺭﺟﻪ ﭼﺮﺧﯿﺪﻩ ﺗﺎ ﺩﺭ ﺩﻭﺍﺭ ﻣﻘﺎﺑﻞ ﻗﺮﺍﺭ ﮔﯿﺮﺩ.
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺩﻭﺍﺭ ﺛﺎﺑﺖ
ﺻﻔﺤﻪ / 6ﺷﻤﺎﺭﻩ 30
ﻧﺎﻣﯿــﺪﻩ ﻣﯽﺷــﻮﺩ ،ﺩﻭﺍﺭ ﺯﯾﺮﯾﻦ ﺭﺍ ﺩﺭ ﻣﮑﺎﻥ ﺯﺍﻭﯾــﻪﺍﯼ ﺛﺎﺑﺘﯽ ﻧﮕﻪ ﺩﺍﺷﺘﻪ ،ﻣﺎﻧﻊ ﺍﺯ ﭼﺮﺧﺶ ﺁﻥ ﺷﺪﻩ ﻭ ﺑﻪ ﺁﻥ ﺍﻣﮑﺎﻥ ﺣﺮﮐﺖ ﺷﻌﺎﻋﯽ ﺭﺍ ﺩﺭ ﻣﺴﯿﺮﯼ ﺩﻭﺭﺍﻧﯽ ﻣﯽﺩﻫﺪ.
ﻣﯽﺑﺮﻧﺪ .ﯾﮏ ﮐﻤﭙﺮﺳــﻮﺭ ﺷــﻌﺎﻋﯽ ﺗﻄﺒﯿﻘﯽ ﺑﻪ ﺩﻭﺍﺭ ﺩﻭﺍﺭ ﺍﻣﮑﺎﻥ
ﺩﺭ ﻫﻨﮕﺎﻡ ﺟﻤﻊ ﺷﺪﻥ ،ﻟﺒﻪ ﭘﺮﻩﻫﺎﯼ ﺩﻭﺍﺭﻫﺎﯼ ﺑﺎﻻ ﻭ ﭘﺎﯾﯿﻦ ﺑﻪ ﺻﻮﺭﺕ ﻫﻼﻟﯽ ﺟﻤﻊ ﻣﯽﺷﻮﻧﺪ .ﺑﺎ ﺣﻠﻘﻪ ﺷﺪﻥ ﺩﻭﺍﺭ ﺯﯾﺮﯾﻦ ،ﻧﻘﺎﻁ ﺁﺏﺑﻨﺪﯼ )ﻧﻘﺎﻁ ﺗﻤﺎﺳﯽ ﺭﻭﯼ ﭘﺮﻩﻫﺎ( ﺑﻪ ﺳﻤﺖ ﺩﺍﺧﻞ ﺭﻓﺘﻪ ﻭ ﺷﮑﻞ ﻫﻼﻟﯽ ﺭﺍ ﺑﻪ ﺳــﻤﺖ ﻣﺮﮐﺰ ﻣﯽﺭﺍﻧﺪ .ﺑﺎ ﺍﯾﻦ ﺣﺮﮐﺖ ،ﻓﺸﺎﺭ ﺗﺮﺍﮐﻤﯽ ﺑــﺮ ﮔﺎﺯ ﺑﻪﺩﺍﻡﺍﻓﺘﺎﺩﻩ ،ﺍﻓﺰﺍﯾﺶ ﻣﯽﯾﺎﺑﺪ .ﺗﺼﻮﯾﺮ ) (4ﻧﺸــﺎﻥﺩﻫﻨﺪﻩ ﺩﻭﺭﺍﻥﻫﺎ ،ﺣﺮﮐﺖ ﻭ ﺗﻐﯿﯿﺮ ﺩﺭ ﺍﯾﻦ ﮔﺎﺯ ﺑﻪﺩﺍﻡﺍﻓﺘﺎﺩﻩ ﺍﺳﺖ.
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﻣﯽﺩﻫﺪ ﺗﺎ ﻣﺴــﯿﺮﯼ ﺩﻭﺍﺭ ﺭﺍ ﮐﻪ ﺑﻪ ﻭﺳﯿﻠﻪ ﺗﻤﺎﺱ ﺁﻥ ﺑﺎ ﺩﻭﺍﺭ ﺛﺎﺑﺖ ﭘﺪﯾﺪ ﻣﯽﺁﯾﺪ )ﻣﺎﻧﻨﺪ ﺑﺎﺩﺍﻣﮏ ﻭ ﭘﯿﺮﻭ( ،ﺑﭙﯿﻤﺎﯾﺪ .ﭘﻮﺳﺘﻪ ﻏﯿﺮﺣﺎﻣﻞ ﻧﺼﺐﺷــﺪﻩ ﺑﯿــﻦ ﺩﻭﺍﺭ ﺩﻭﺍﺭ ﻭ ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ ،ﺍﻧﺤﺮﺍﻓﺎﺕ ﺷــﻌﺎﻋﯽ ﭘﺪﯾﺪﺁﻣﺪﻩ ﺑﻪ ﻭﺳــﯿﻠﻪ ﻣﺎﺷــﯿﻦﮐﺎﺭﯼ ﻭ ﺑﺴــﺘﻪﺑﻨﺪﯼ ﺭﺍ ﻣﯽﮔﯿﺮﺩ. ﺗﻄﺒﯿﻖ ﻣﺤﻮﺭﯼ ﺑﻪ ﻗﺎﺑﻠﯿﺖ ﺩﻭﺍﺭﻫﺎﯼ ﺩﻭﺍﺭ ﻭ ﺛﺎﺑﺖ ﻧﺴﺒﺖ ﺑﻪ ﻣﺤﻮﺭ ﻣﺠﺰﺍ ﻣﺮﺑﻮﻁ ﻣﯽﺷــﻮﺩ .ﺩﺭ ﮐﻤﭙﺮﺳــﻮﺭ ﻏﯿﺮﺗﻄﺒﯿﻘﯽ ،ﺩﻭﺍﺭ ﻣﺴﯿﺮ ﺛﺎﺑــﺖ ﺩﻭﺭﺍﻧﯽ ﺭﺍ ﻃــﯽ ﮐﺮﺩﻩ ﻭ ﻫﺮﮔﺰ ﺑﺎ ﺩﻭﺍﺭﻫﺎﯼ ﺛﺎﺑﺖ ،ﺗﻤﺎﺳــﯽ
ﺩﺭ ﺗﺼﻮﯾﺮ ) ،(4ﻧﺨﺴــﺘﯿﻦ ﺩﻭﺭ ﺑﺎ ﺑﺎﺯﺷﺪﻥ ﮐﺎﻣﻞ ﻫﺮ ﺩﻭ ﺩﻭﺍﺭ
ﻧﺪﺍﺭﺩ .ﮐﺮﯾﺮ ﻭ ﺩﻧﻔﻮﺱ ،ﺍﯾﻦ ﻃﺮﺡ ﺭﺍ ﺑﻪ ﻋﻨﻮﺍﻥ ﺩﻭﺭﺍﻥ ﮐﻨﺘﺮﻝﺷﺪﻩ
ﺷﺮﻭﻉ ﺷــﺪﻩ ﻭ ﻓﻀﺎﯾﯽ ﺑﺮﺍﯼ ﭘﺮ ﺷــﺪﻥ ﺑﺎ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺑﺎ ﻓﺸﺎﺭ
ﻣﯽﺷﻨﺎﺳﻨﺪ .ﺭﺍﺑﻄﻪ ﻫﻨﺪﺳﯽ ﺑﯿﻦ ﺩﻭﺍﺭﻫﺎ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭﯼ ﺑﺎ ﺩﻭﺭﺍﻥ
ﭘﺎﯾﯿﻦ ﻓﺮﺍﻫﻢ ﻣﯽﺁﻭﺭﺩ )ﻣﻮﻗﻌﯿﺖ .(Aﻣﺪﺍﺭ ﺩﻭﺍﺭ ﺯﯾﺮﯾﻦ ،ﻧﺨﺴﺘﯿﻦ
ﮐﻨﺘﺮﻝﺷﺪﻩ ،ﺛﺎﺑﺖ ﻭ ﺗﺤﺖ ﺷﺮﺍﯾﻂ ﻋﻤﻠﯿﺎﺗﯽ ﺍﺳﺖ.
ﺑﺴــﺘﻪﻫﺎﯼ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ﺭﺍ ﻣﯽﺑﻨﺪﺩ )ﻣﻮﻗﻌﯿــﺖ .(Cﺑﺎ ﭘﺎﯾﺎﻥ
ﺗﺼﻤﯿﻢ ﺑﺮﺍﯼ ﺳــﺎﺧﺖ ﮐﻤﭙﺮﺳــﻮﺭﯼ ﺑﺎ ﺩﻭﺍﺭﻫــﺎﯼ ﻣﻤﺎﺱ ﺑﺎ
ﻧﺨﺴــﺘﯿﻦ ﺩﻭﺭ ،ﻧﺨﺴــﺘﯿﻦ ﺟﻔﺖ ﺷــﮑﻞﻫﺎﯼ ﻫﻼﻟﯽ ﺑﻪ ﺳﻤﺖ
ﯾﮑﺪﯾﮕــﺮ ﯾﺎ ﺩﻭﺍﺭﻫﺎﯾﯽ ﺑــﺪﻭﻥ ﺗﻤﺎﺱ ﺩﺭ ﺩﻭﺭﺍﻥ ﮐﻨﺘﺮﻝﺷــﺪﻩ ،ﺑﺮ
ﻣﻮﻗﻌﯿﺖ ﻣﯿﺎﻧﯽ ﺭﻓﺘﻪ ﻭ ﺩﻭﺍﺭ ﺧﺎﺭﺟﯽ ﺩﻭﺑﺎﺭﻩ ﺷــﺮﻭﻉ ﺑﻪ ﺑﺎﺯﺷــﺪﻥ
ﺍﺳﺎﺱ ﺭﻭﺵ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﺭ ﺁﺏﺑﻨﺪﯼ ﺩﻭﺍﺭﻫﺎ ﺍﺳﺖ.
ﻣﯽﮐﻨﺪ ﺗﺎ ﻣﻘﺪﺍﺭ ﺑﯿﺸﺘﺮﯼ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺑﺎ ﻓﺸﺎﺭ ﺍﻧﺪﮎ ﺭﺍ ﻫﺪﺍﯾﺖ ﮐﻨﺪ )ﻣﻮﻗﻌﯿﺖ .(Dﺩﻭﻣﯿﻦ ﺩﻭﺭ ،ﺑﺴــﺘﻪﻫﺎﯼ ﮔﺎﺯ ﻧﺨﺴﺘﯿﻦ ﺭﺍ ﺑﻪ ﺳﻤﺖ ﻣﺮﮐﺰ ﺩﻭﺍﺭ ﺭﺍﻧﺪﻩ ،ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﺣﺠﻢ ﮔﺎﺯ ﻭ ﺍﻓﺰﺍﯾﺶ ﻓﺸﺎﺭ
ﻓﻨﻮﻥ ﺁﺏﺑﻨﺪﯼ ﻋﻤﻠﮑﺮﺩ ﺁﺏﺑﻨﺪﯼ ﻣﺴﺘﻘﯿﻤﺎ ﺑﺴﺘﮕﯽ ﺑﻪ ﻧﺸﺖ ﺩﺍﺧﻠﯽ ﻭ ﺍﺗﻼﻑ ﻣﮑﺎﻧﯿﮑــﯽ ﺩﺍﺭﺩ .ﻫﺮ ﺑﺴــﺘﻪ ﻫﻼﻟﯽ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﻪﺩﺍﻡﺍﻓﺘﺎﺩﻩ
ﺁﻥ ﻣﯽﺷﻮﺩ .ﻧﺨﺴــﺘﯿﻦ ﺩﻭﺭ ﺑﺎ ﺑﺴﺘﻪﻫﺎﯼ ﻫﻼﻟﯽ ﺷﮑﻞ ﺑﯿﺮﻭﻥ ﺍﺯ
ﺑﯿــﻦ ﭘﺮﻩﻫﺎﯼ ﺩﻭﺍﺭ ،ﻃﺒﯿﻌﺘــﺎ ﺩﻧﺒﺎﻝ ﺟﺎﯾﯽ ﺑﺮﺍﯼ ﺗﻌﺎﺩﻝ ﺍﺳــﺖ.
ﺩﻭﺍﺭ ﻣﺮﮐﺰﯼ ﺷــﺮﻭﻉ ﻣﯽﺷﻮﺩ .ﺑﺎ ﺍﺩﺍﻣﻪ ﺩﻭﺭ ﺳﻮﻡ ،ﺍﻧﺘﻬﺎﯼ ﺩﺍﺧﻠﯽ
ﺍﮔﺮ ﮔﺎﺯ ﺩﺭ ﯾﮏ ﺳــﻤﺖ ﭘﺮﻩ ،ﻓﺸــﺎﺭﯼ ﺑﯿﺶ ﺍﺯ ﮔﺎﺯ ﺳــﻤﺖ ﺩﯾﮕﺮ
ﭘﺮﻩﻫﺎ ﺗﻤﺎﺱ ﺭﺍ ﺷﮑﺴــﺘﻪ )ﻣﻮﻗﻌﯿﺖ ،(Jﻫﻮﺍﯼ ﻓﺸﺮﺩﻩ ﺭﺍ ﺑﻪ ﻣﺮﮐﺰ
ﺩﺍﺷﺘﻪ ﺑﺎﺷــﺪ ،ﺟﺮﯾﺎﻧﯽ ﺑﻪ ﺳﻤﺖ ﻓﺸﺎﺭ ﭘﺎﯾﯿﻦ ﭘﺪﯾﺪ ﺧﻮﺍﻫﺪ ﺁﻭﺭﺩ.
ﻭﺍﺣــﺪ ﺗﺨﻠﯿﻪ ﻫﺪﺍﯾﺖ ﻣﯽﮐﻨﺪ .ﺩﻭﺭ ﺳــﻮﻡ ،ﭼﺮﺧﻪ ﺗﺮﺍﮐﻢ ﺭﺍ ﺍﺩﺍﻣﻪ
ﺩﺭ ﮐﻤﭙﺮﺳــﻮﺭﯼ ﺩﻭﺍﺭ ،ﺗﻨﻬﺎ ﺩﻭ ﺭﺍﻩ ﺑﺮﺍﯼ ﺍﯾﻦ ﻧﺸــﺖ ﻭﺟﻮﺩ ﺩﺍﺭﺩ،
ﺩﺍﺩﻩ ،ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﺎ ﻓﺸــﺎﺭ ﺑﺎﻻ ﺭﺍ ﺗﺨﻠﯿﻪ ﻣﯽﮐﻨﺪ )ﻣﻮﻗﻌﯿﺖ
ﺷﻌﺎﻋﯽ ﻭ ﻣﺤﻮﺭﯼ.
.(L ﺗﻠﻔﻦ88739880-2:
ﺑﺮﺧﯽ ﺍﺯ ﺳﺎﺯﻧﺪﮔﺎﻥ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﺍﺯ ﻭﺍﮊﻩ ﺗﻄﺒﯿﻖ ،ﺑﺮﺍﯼ ﺗﻌﺮﯾﻒ ﺣﺮﮐﺖ ﺩﻭﺭﺍﻧﯽ ﺑﯿﻦ ﺩﻭﺍﺭﻫﺎﯼ ﺑﺎﻻ ﻭ ﭘﺎﯾﯿﻦ ﺩﺭ ﯾﮏ ﮐﻤﭙﺮﺳﻮﺭ ،ﺑﻬﺮﻩ
ﻧﯿﺮﻭﻫﺎﯼ ﺗﺮﺍﮐﻤﯽ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺗﻄﺒﯿﻖ
ﺗﺼﻮﯾﺮ ) (6ﻧﺸــﺎﻥﺩﻫﻨﺪﻩ ﻧﺸﺖ ﺷــﻌﺎﻋﯽ ﺑﯿﻦ ﻟﺒﻪ ﺗﯿﻐﻪﻫﺎﯼ ﺑﺎﯾﺪ ﺑﻪ ﺗﻘﺎﺭﻥ ﺩﻭﺍﺭ ﻭ ﺑﺴﺘﻪﻫﺎﯼ ﻫﻼﻟﯽ ﺷﮑﻞ ،ﺗﻮﺟﻪ ﺩﺍﺷﺖ.
ﺩﻭﺍﺭﯼ ﺍﺳــﺖ ﮐﻪ ﮔﺎﺯ ﺑﺴﺘﻪ ﻫﻼﻟﯽ ﺑﺎ ﻓﺸــﺎﺭ ﺑﺎﻻ ﺍﺯ ﻃﺮﯾﻖ ﺁﻥﻫﺎ،
ﺷــﮑﻞ ﻭ ﻣﻮﻗﻌﯿﺖ ﺑﺴﺘﻪﻫﺎﯼ ﺗﻌﺮﯾﻒﺷــﺪﻩ ﺩﺭ ﺑﺎﻻ ﻣﺘﻘﺎﺭﻥ ﺑﻮﺩﻩ
ﺳــﻌﯽ ﺩﺭ ﺭﺳﯿﺪﻥ ﺑﻪ ﺑﺴﺘﻪ ﮔﺎﺯ ﻓﺸﺎﺭ ﭘﺎﯾﯿﻦ ﺩﺍﺭﺩ .ﻧﺸﺖ ﻣﺤﻮﺭﯼ
ﻭ ﺩﺭ ﺟﻬــﺖ ﻣﺨﺎﻟﻒ ﯾﮑﺪﯾﮕــﺮ ﻭ ﺩﺭ ﺍﻣﺘﺪﺍﺩ ﭼﺮﺧــﻪ ﺗﺮﺍﮐﻢ ﮐﺎﻣﻞ
ﺑﯿــﻦ ﻧﻮﮎ ﭘﺮﻩ ﺩﻭﺍﺭ )ﻟﺒــﻪ ﺁﺯﺍﺩ ﺩﻭﺍﺭ( ﻭ ﺻﻔﺤﻪ ﺩﻭﺍﺭ ﻣﻘﺎﺑﻞ ،ﺭﻭﯼ
ﺍﺳــﺖ )ﺳــﻪ ﻣﺪﺍﺭ( .ﺗﻘﺎﺭﻥ ﻃﺒﯿﻌــﯽ ﺩﺭ ﻣﺤــﻞ ﺩﻭﺍﺭ ،ﻧﯿﺮﻭﻫﺎﯼ
ﻣﯽﺩﻫﺪ .ﻧﺸــﺖ ﻣﺤﻮﺭﯼ ﻣﻌﻤﻮﻻ ﻣﻬﻢﺗﺮ ﺍﺯ ﻧﺸــﺖ ﺷﻌﺎﻋﯽ ﺗﻠﻘﯽ
ﺷــﻌﺎﻋﯽ ﮔﺎﺯ ﺭﺍ ﺩﺭﺑﺮﺍﺑﺮ ﭘﺮﻩﻫﺎ ﻣﺘﻌﺎﺩﻝ ﮐــﺮﺩﻩ ،ﺑﺎﻋﺚ ﭘﺪﯾﺪ ﺁﻣﺪﻥ
ﻣﯽﺷﻮﺩ(ASHRAE 2004).
ﭼﺮﺧــﻪ ﺗﺮﺍﮐﻢ ﻧﺮﻣﯽ ﻣﯽﺷــﻮﺩ .ﻋﻼﻭﻩ ﺑﺮ ﺍﯾﻦ ،ﻫــﺮ ﻣﺪﺍﺭ ،ﭼﺮﺧﻪ
ﻧﺸﺖ ﺑﺎﻋﺚ ﺍﻓﺰﺍﯾﺶ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ،ﮐﺎﻫﺶ ﻇﺮﻓﯿﺖ ﮐﻤﭙﺮﺳﻮﺭ
ﺗﺮﺍﮐﻢ ﺭﺍ ﺑﻪ ﮔﻮﻧﻪﺍﯼ ﺷــﺮﻭﻉ ﻣﯽﮐﻨﺪ ﮐﻪ ﺩﺭ ﻫﺮ ﺯﻣﺎﻥ ،ﺳــﻪﺟﻔﺖ
ﻭ ﭘﺎﯾﯿﻦ ﺁﻣﺪﻥ ﮐﺎﺭﺍﯾﯽ ﻣﯽﺷﻮﺩ.
ﺑﺴــﺘﻪ ﻫﻼﻟﯽﺷﮑﻞ ﻣﺘﻘﺎﺭﻥ ﺩﺭ ﺷﺮﺍﯾﻂ ﻓﺸــﺎﺭ ﭘﺎﯾﯿﻦ ،ﻣﺘﻮﺳﻂ ﻭ
ﺁﺏﺑﻨﺪﯼ ﺷﻌﺎﻋﯽ
ﺑﺎﻻ ﻭﺟﻮﺩ ﺩﺍﺭﻧﺪ ﺗﺼﻮﯾﺮ ) .(5ﺑﯿﻦ ﻣﻮﻗﻌﯿﺖﻫﺎﯼ Aﻭ Lﺩﺭ ﺗﺼﻮﯾﺮ
ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺗﻄﺒﯿﻘﯽ ،ﺍﺯ ﺗﻤﺎﺱ ﺑﯿﻦ ﺩﻭﺍﺭﻫﺎﯼ ﻣﺘﺤﺮﮎ ﻭ
) ،(4ﺗﺮﺍﮐﻢ ﻓﺮﺁﯾﻨﺪﯼ ﻧﺮﻡ ﻭ ﭘﯿﻮﺳــﺘﻪ ﺑﻮﺩﻩ ﻭ ﻣﺎﻧﻨﺪ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ
ﺛﺎﺑﺖ ﻣﺎﻧﻨﺪ ﻣﮑﺎﻧﯿﺰﻡ ﺁﺏﺑﻨﺪﯼ ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ؛ ﺍﻟﺒﺘﻪ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ
ﻣﺘﻨﺎﻭﺏ ،ﺑﺪﻭﻥ ﻟﺮﺯﺵ ﯾﺎ ﺍﺭﺗﻌﺎﺷﯽ ﻗﻮﯼ ﺍﺳﺖ.
ﺗﻄﺒﯿﻘــﯽ ﺷــﻌﺎﻋﯽ ﻣﻤﮑﻦ ﺍﺳــﺖ ﺩﺭ ﺯﻣﯿﻨﻪ ﺁﺏﺑﻨــﺪﯼ ،ﮐﺎﺭﺍﯾﯽ
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 7ﺷﻤﺎﺭﻩ 30
ﻣﺴﯿﺮ ﺩﻭﺭ ﺩﻭﺍﺭ ﺛﺎﺑﺖ )ﺳﻔﯿﺪ(
ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ )ﺧﺎﮐﺴﺘﺮﯼ( ﺩﻭﺭ ﺳﻮﻡ
ﺩﻭﺭ ﺩﻭﻡ
ﺩﻭﺭ ﺍﻭﻝ
ﺩﺭ ﻣﻘﺎﺑﻞ ،ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﻣﺪﺍﺭﯼ ﮐﻨﺘﺮﻝﺷــﺪﻩ ،ﺑﺮ ﺳــﻄﺢ
ﻧﻤﯽﺷــﻮﺩ .ﺍﯾﻦ ﻓﺎﺻﻠﻪ ﺑﻪﻗﺪﺭﯼ ﺩﻗﯿﻖ ﺍﺳﺖ ﮐﻪ ﺗﻨﻬﺎ ﻻﯾﻪ ﻧﺎﺯﮐﯽ
ﺩﻭﺍﺭ ﺩﻗﯿﻘــﯽ ﺑﺮﺍﯼ ﺍﻃﻤﯿﻨﺎﻥ ﺍﺯ ﻣﻨﺎﺳــﺐ ﺑــﻮﺩﻥ ﻟﺒﻪ ﺩﻭﺍﺭ ،ﺗﮑﯿﻪ
ﺭﻭﻏﻦ ،ﺁﻥ ﺭﺍ ﺁﺏﺑﻨﺪﯼ ﮐﺮﺩﻩ ﻭ ﺳــﻄﺤﯽ ﺭﻭﻏﻦﮐﺎﺭﯼ ﺑﺮﺍﯼ ﺣﺮﮐﺖ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺍﯾﻦ ﺗﻤﺎﺱ ،ﺗﻄﺒﯿﻖ ﺭﺍ ﺍﻟﺰﺍﻣﯽ ﻣﯽﮐﻨﺪ.
ﻣﯿﻠﯿﻮﻧﯿﻮﻡ ﻣﺘﺮ ﯾﺎ 0.000039ﺍﯾﻨﭻ ﺍﺳﺖ( .ﻧﻮﮎ ﭘﺮﻩ ﻫﺮﮔﺰ ﻣﻤﺎﺱ
ﺗﻠﻔﻦ55401278 :
ﻧﯿﺎﺯﻣﻨﺪ ﻣﺮﺣﻠﻪ ﺳﺎﯾﺶ ﻫﺴــﺘﻨﺪ ﺗﺎ ﺗﻤﺎﻡ ﺳﻄﻮﺡ ﻣﺘﻌﺎﺩﻝ ﺷﻮﻧﺪ.
ﻭ ﺍﻧﺤﺮﺍﻑ ﺭﺍ ﺑﻪ ﺳــﻄﺢ ﻣﯿﮑﺮﻭﻥ ﻣﯽﺭﺳــﺎﻧﺪ )ﯾــﮏ ﻣﯿﮑﺮﻭﻥ ﯾﮏ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﯾﮑﺴــﺎﻧﯽ ﺩﺭ ﺗﻤــﺎﻡ ﻧﻘﺎﻁ ﺗﻤﺎﺱ ﻧﺪﺍﺷــﺘﻪ ﺑﺎﺷــﻨﺪ .ﺍﯾﻦ ﻃﺮﺡﻫﺎ
ﻣﯽﮐﻨﻨﺪ .ﺍﺑﺰﺍﺭ ﻣﺎﺷــﯿﻨﯽ ﮐﺎﻣﭙﯿﻮﺗﺮﯼ ،ﺳﻄﺢ ﺩﻗﯿﻘﯽ ﭘﺪﯾﺪ ﺁﻭﺭﺩﻩ
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺗﺼﻮﯾﺮ ) (4ﭼﺮﺧﻪ ﺗﺮﺍﮐﻢ ﮐﺎﻣﻞ ﻧﯿﺎﺯﻣﻨﺪ ﭼﻨﺪ ﺩﻭﺭ ﺍﺳﺖ ﺗﺎ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺍﺯ ﺷﺮﺍﯾﻂ ﻣﮑﺶ ﻓﺸﺎﺭ ﭘﺎﯾﯿﻦ )ﻣﻮﻗﻌﯿﺖ (A ﺑﻪ ﺗﺨﻠﯿﻪ ﻓﺸﺎﺭ ﺑﺎﻻ )ﻣﻮﻗﻌﯿﺖ (Lﺑﺮﺳﺪ.
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﺻﻔﺤﻪ / 8ﺷﻤﺎﺭﻩ 30
ﺩﻭﺍﺭ ﺑﺪﻭﻥ ﻫﯿﭻ ﺍﺻﻄﮑﺎﮎ ﯾﺎ ﺳﺎﯾﺸــﯽ ﭘﺪﯾــﺪ ﻣﯽﺁﻭﺭﺩ .ﺑﻪ ﺩﻟﯿﻞ
ﺑﺮﺍﯼ ﺑﺎﺭﮔﺬﺍﺭﯼ ﺩﻭﺍﺭ ﺛﺎﺑﺖ ﺩﺭ ﺑﺮﺍﺑﺮ ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ ،ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ.
ﺁﻥﮐﻪ ﺩﻭﺭﺍﻥ ﮐﻨﺘﺮﻝﺷﺪﻩ ،ﻫﯿﭻ ﺗﻤﺎﺳﯽ ﺑﯿﻦ ﭘﺮﻩﻫﺎ ﺭﺍ ﻧﻤﯽﭘﺬﯾﺮﺩ،
ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﮐﻨﺘﺮﻝﺷﺪﻩ ،ﺗﻤﺎﺱ ﻣﺘﺤﺮﮎ ﺭﺍ ﺑﯿﻦ ﻧﻮﮎ
ﺗﻄﺒﯿﻖ ﺿﺮﻭﺭﯼ ﻧﺒﻮﺩﻩ ﻭ ﮐﻤﭙﺮﺳــﻮﺭ ﻫﻨﺪﺳــﻪ ﺛﺎﺑﺘﯽ ،ﻭﺭﺍﯼ ﻋﻤﺮ
ﭘﺮﻩ ﺩﻭﺍﺭ ﻭ ﺻﻔﺤﻪ ﺛﺎﺑﺖ ،ﺑﺎ ﺁﺏﺑﻨﺪﯼﻫﺎﯼ ﺷﻨﺎﻭﺭ ﺗﺎﻣﯿﻦ ﻣﯽﮐﻨﻨﺪ.
ﻣﺤﻞ ﺩﻭﺍﺭ ،ﺧﻮﺍﻫﺪ ﺩﺍﺷﺖ.
ﺷﯿﺎﺭﻫﺎﯼ ﻣﺎﺷﯿﻦﺷﺪﻩ ﺩﺭ ﻧﻮﮎ ﭘﺮﻩﻫﺎ ،ﺍﺟﺰﺍﯼ ﺁﺏﺑﻨﺪﯼ ﺭﺍ ﮐﻪ ﺑﯿﻦ ﭘﺮﻩ ﻭ ﺻﻔﺤﻪ ﻣﻘﺎﺑﻞ ﺍﺳﺖ ،ﺷﻨﺎﻭﺭ ﻧﮕﻪ ﻣﯽﺩﺍﺭﺩ ،ﺗﺼﻮﯾﺮ ) .(7ﻓﺸﺎﺭ
ﺁﺏﺑﻨﺪﯼ ﻣﺤﻮﺭﯼ ﺗﻄﺒﯿــﻖ ،ﻣﺒﺘﻨﯽ ﺑﺮ ﺗﻤﺎﺱ ﺑﯿﻦ ﻧﻮﮎ ﭘــﺮﻩ ﻭ ﺻﻔﺤﻪ ﻣﻘﺎﺑﻞ ﺍﺳﺖ .ﺍﻧﻌﻄﺎﻑﭘﺬﯾﺮﯼ ﻣﺤﻮﺭﯼ ﺑﺮﺍﯼ ﻓﺎﺻﻠﻪ ﭘﺪﯾﺪﺁﻣﺪﻩ ﺩﺭ ﺍﺛﺮ ﺭﺷﺪ ﺣﺮﺍﺭﺗﯽ ﻭ ﺳــﺎﯾﺶ ،ﺿﺮﻭﺭﯼ ﺍﺳﺖ .ﺑﺮﺧﯽ ﺳﺎﺯﻧﺪﮔﺎﻥ ﺍﺯ ﻓﺸﺎﺭ ﮔﺎﺯ
ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ،ﺑﺎﺭ ﺁﺏﺑﻨﺪﯼ ﺭﺍ ﺑﺮ ﺻﻔﺤﻪ ﺑﺮﺍﯼ ﺗﻤﺎﺱ ﻣﺘﺤﺮﮎ ﺩﻗﯿﻘــﯽ ﺩﺭﻃﻮﻝ ﻋﻤﻠﯿــﺎﺕ ،ﺗﺤﻤﻞ ﻣﯽﮐﻨﺪ .ﻧﯿﺮﻭﻫﺎﯼ ﺗﻤﺎﺳــﯽ ﺑﺴــﯿﺎﺭ ﮐﻮﭼﮏ ﺑﻮﺩﻩ ﻭ ﺩﺭ ﺗﺮﮐﯿﺐ ﺑﺎ ﺳﻄﺢ ﺗﻤﺎﺱ ﮐﺎﻫﺶ ﯾﺎﻓﺘﻪ، ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﺍﺗﻼﻑ ﺍﺻﻄﮑﺎﮐﯽ ﻭ ﺍﻓﺰﺍﯾﺶ ﮐﺎﺭﺍﯾﯽ ﻣﯽﺷﻮﻧﺪ.
ﺳﺎﺧﺘﺎﺭ ﻭ ﻋﻤﻠﮑﺮﺩ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ،ﺷــﮕﻔﺖﺍﻧﮕﯿﺰﻧﺪ .ﻣﺤﻞ ﺩﻭﺍﺭ ،ﻣﻔﺼﻞ،
ﺩﻭﺍﺭ ﺛﺎﺑﺖ )ﺳﻔﯿﺪ( ﺗﺨﻠﯿﻪ ﺳﺮﻣﺎﯾﺸﯽ ﺑﺎ ﻓﺸﺎﺭ ﺑﺎﻻ
ﻭﺯﻧﻪ ﺗﻌﺎﺩﻝ ،ﻣﻮﺗﻮﺭ ﻭ ﯾﺎﺗﺎﻗﺎﻥﻫﺎ ،ﺩﺭ ﺍﺳﺘﻮﺍﻧﻪﺍﯼ ﺟﻤﻊ ﺷﺪﻩ ﻭ ﺭﻭﯼ ﺁﻥﻫﺎ ﺭﺍ ﭘﻮﺳﺘﻪﺍﯼ ﻓﻮﻻﺩﯼ ﻣﯽﭘﻮﺷﺎﻧﺪ .ﺍﻏﻠﺐ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ
ﺳﺮﻣﺎﯾﺸﯽ ﻓﺸﺎﺭ ﺑﺎﻻ
ﺩﺭ ﺯﻣﯿﻨﻪ ﺳــﺮﻣﺎﯾﺶ ﻭ ﺗﻬﻮﯾﻪ ﻣﻄﺒــﻮﻉ ،ﺟﻬﺘﯽ ﻋﻤﻮﺩﯼ ﺑﺎ ﻣﺤﻞ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺩﻭﺍﺭ ﻣﺴﺘﻘﺮ ﺩﺭ ﺑﺎﻻﯼ ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ ﺩﺍﺭﻧﺪ )ﺗﺼﻮﯾﺮ .(8 ﺑﺎ ﻭﺟﻮﺩ ﺗﻔﺎﻭﺕﻫﺎ ﺩﺭ ﺗﻮﻟﯿﺪ ،ﺳــﺎﺧﺘﺎﺭ ﭘﺎﯾﻪ ﻣﺸــﺎﺑﻪ ﺍﺳــﺖ. ﺳﺮﻣﺎﯾﺸﯽ ﻓﺸﺎﺭ ﻣﺘﻮﺳﻂ ﺳﺮﻣﺎﯾﺸﯽ ﻓﺸﺎﺭ ﭘﺎﯾﯿﻦ
ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ )ﺧﺎﮐﺴﺘﺮﯼ(
ﺗﺼﻮﯾﺮ ) (5ﺑﻪ ﺩﻟﯿﻞ ﺍﺩﺍﻣﻪ ﻓﺮﺁﯾﻨﺪ ﺗﺮﺍﮐﻢ ،ﺩﺭ ﻫﺮ ﺯﻣﺎﻥ ﭘﺮﻩﻫﺎﯼ ﺩﻭﺍﺭ ﺣﺎﻭﯼ ﺑﺴﺘﻪﻫﺎﯾﯽ ﺍﺯ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺑﺎ ﻓﺸﺎﺭﻫﺎﯼ ﭘﺎﯾﯿﻦ ،ﻣﺘﻮﺳﻂ ﻭ ﺑﺎﻻ ﻫﺴﺘﻨﺪ.
ﺗﻌﺎﺭﯾﻒ ﺯﯾﺮ ﻣﺒﺘﻨﯽ ﺑﺮ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ﮐﻨﺘﺮﻟﯽ ﺍﺳﺘﻔﺎﺩﻩﺷــﺪﻩ ﺩﺭ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ Aqua Snapﮐﺮﯾﺮ ﻫﺴﺘﻨﺪ.
ﭘﻮﺳﺘﻪ ﭘﻮﺳﺘﻪ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ،ﺍﺳﺘﻮﺍﻧﻪﺍﯼ ﻭ ﻋﻤﻮﺩﯼ ﺑﻮﺩﻩ ﻭ ﺑﻪ ﺩﻭ ﺑﺨﺶ ﻓﺸــﺎﺭﭘﺎﯾﯿﻦ ﻭ ﻓﺸﺎﺭﺑﺎﻻ ﺗﻘﺴﯿﻢ ﻣﯽﺷﻮﺩ .ﺑﺰﺭﮒﺗﺮﯾﻦ ﺑﺨﺶ ﭘﻮﺳﺘﻪ ،ﺑﻪ ﻓﺸﺎﺭ ﻣﮑﻨﺪﻩ ﺳﺮﻣﺎﯾﺸﯽ ﻣﺮﺑﻮﻁ ﺍﺳﺖ ﻭ ﺷﺎﻣﻞ ﻣﻮﺗﻮﺭ، ﭘﻤﭗ ﺭﻭﻏﻦ ﻭ ﺍﺟﺰﺍﯼ ﻣﺘﺤﺮﮎ ﺩﻭﺍﺭ ﻣﯽﺷﻮﺩ .ﻧﺎﺣﯿﻪﺍﯼ ﮐﻮﭼﮏ ﺑﺎ ﻓﺸــﺎﺭ ﺑﺎﻻ ﺩﺭ ﺑﺎﻻﯼ ﺩﻭﺍﺭ ﺛﺎﺑﺖ ﮐﻤﭙﺮﺳﻮﺭ ﻗﺮﺍﺭ ﺩﺍﺷﺘﻪ ﻭ ﺑﻪ ﻋﻨﻮﺍﻥ ﻟﺮﺯﺵ ﻋﻤﻞ ﻣﯽﮐﻨﺪ. ﮔﺎﺯ ﻣﮑــﺶ ﺳﺮﻣﺎﯾﺸــﯽ ،ﺍﺯﻃﺮﯾﻖ ﺍﺗﺼﺎﻝ ﭘﺎﯾﯿﻦ ﻭﺍﺭﺩ ﭘﻮﺳــﺘﻪ
ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﻋﺎﻣــﻞ ﺗﺨﻠﯿﻪﺍﯼ ﺑﺮﺍﯼ ﮐﺎﻫﺶ ﺻﺪﺍﯼ ﻧﺎﺷــﯽ ﺍﺯ ﺍﺭﺗﻌﺎﺵ ﮔﺎﺯﯼ ﻭ
ﻣﮑﺶ ﺑﺰﺭﮒ ﻣﯽﺷــﻮﺩ .ﺳــﺮﻋﺖ ﮔﺎﺯ ﺩﺭ ﭘﻮﺳــﺘﻪ ﮐﺎﻫﺶ ﯾﺎﻓﺘﻪ، ﺍﻣــﮑﺎﻥ ﺭﻭﻏﻦﮐﺎﺭﯼ ﻭ ﺳــﺮﻣﺎﯾﺶ ﻣﺎﯾﻊ ﺭﺍ ﺑــﺮﺍﯼ ﺟﺪﺍﯾﯽ ﺍﺯ ﮔﺎﺯ، ﻣﯽﺩﻫﺪ .ﺩﺭ ﭘﻮﺳﺘﻪ ﮐﻤﭙﺮﺳﻮﺭ ،ﺗﻤﺎﻡ ﮔﺎﺯ ﻣﮑﺶ ﺍﺯ ﻃﺮﯾﻖ ﻣﻮﺗﻮﺭ ﺑﻪ ﺳﻤﺖ ﺩﻭﺍﺭ ﺑﺎﻻ ﻣﯽﺭﻭﺩ .ﻣﻘﺪﺍﺭ ﮐﻤﯽ ﺭﻭﻏﻦ ﺑﻪ ﺻﻮﺭﺕ ﻏﺒﺎﺭ ﺑﺎ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺑﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺭﻓﺘﻪ ،ﺭﻭﻏﻦﮐﺎﺭﯼ ﻻﺯﻡ ﺭﺍ ﺑﺮﺍﯼ ﺁﺏﺑﻨﺪﯼ ﻧﺸﺘﯽ ﺷﻌﺎﻋﯽ
ﭘﺮﻩﻫﺎﯼ ﺩﻭﺍﺭ ﻓﺮﺍﻫﻢ ﻣﯽﮐﻨﺪ .ﮔﺎﺯ ﻣﺘﺮﺍﮐﻢﺷــﺪﻩ ﺍﺯ ﻃﺮﯾﻖ ﺷــﯿﺮﯼ
ﻧﺸﺘﯽ ﻣﺤﻮﺭﯼ
ﺑﻪ ﺩﺭﻭﻥ ﻣﺤﻔﻈﻪﺍﯼ ﺑﺎ ﻓﺸــﺎﺭ ﺑﺎﻻ ﺗﺨﻠﯿﻪ ﺷــﺪﻩ ،ﺳﭙﺲ ﺍﺯ ﻃﺮﯾﻖ
ﺗﺼﻮﯾﺮ ) (6ﻧﺸﺘﯽ ﺷﻌﺎﻋﯽ ﺑﯿﻦ ﻣﺤﻞ ﺗﻤﺎﺱ ﻟﺒﻪ ﭘﺮﻩﻫﺎﯼ ﺩﻭﺍﺭ ﻭ ﻧﺸﺘﯽ ﻣﺤﻮﺭﯼ ﺑﯿﻦ ﻧﻮﮎ ﭘﺮﻩﻫﺎ ﻭ ﺩﻭﺍﺭ ﺛﺎﺑﺖ، ﺭﻭﯼ ﻣﯽﺩﻫﻨﺪ. ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺍﺗﺼﺎﻝ ﺗﺨﻠﯿﻪ ﺍﺯ ﭘﻮﺳﺘﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺧﺎﺭﺝ ﻣﯽﺷﻮﺩ. ﺑﺨﺶ ﭘﺎﯾﯿﻨﯽ ﭘﻮﺳــﺘﻪ ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﺨــﺰﻥ ﺭﻭﻏﻦ ﻭ ﻣﺎﯾﻊ ﻋﻤﻞ ﻣﯽﮐﻨﺪ .ﻇﺮﻓﯿﺖ ﺑﺎﻻﯼ ﺍﯾﻦ ﮐﻤﭙﺮﺳﻮﺭ ،ﺍﻣﮑﺎﻥ ﮐﺎﺭ ﺩﺭ ﺳﯿﺴﺘﻢﻫﺎﯾﯽ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 9ﺷﻤﺎﺭﻩ 30
ﭘﺪﯾﺪﺁﻣﺪﻩ ﺩﺭ ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ ،ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ )ﺗﺼﻮﯾﺮ .(9 ﺻﻔﺤﻪ ﭘﺎﯾﻪ ﺩﻭﺍﺭ ﻣﻘﺎﺑﻞ
ﻣﻮﺗﻮﺭ ﻭ ﻣﯿﻞﻟﻨﮓ ﺑﻪ ﺻﻮﺭﺗﯽ ﮐﺎﻣﻼ ﺷﮕﻔﺖﺍﻧﮕﯿﺰ ﻭ ﻣﮑﺶ 100%ﮔﺎﺯ ﺧﻨﮏﺷﺪﻩ، ﻣﻮﺗﻮﺭ ﻗﻔﺴﯽ ﻣﮑﺶ ،ﮐﻤﭙﺮﺳﻮﺭ ﺭﺍ ﺑﻪ ﺣﺮﮐﺖ ﺩﺭﻣﯽﺁﻭﺭﺩ .ﺧﻨﮑﺎﯼ ﮔﺎﺯ ﻣﮑﺸﯽ ،ﻋﻤﺮ ﻣﻮﺗﻮﺭ ﺭﺍ ﺑﺎ ﻧﮕﻪ ﺩﺍﺷﺘﻦ ﻣﻮﺗﻮﺭ ﺩﺭ ﺣﺎﻟﺘﯽ ﺑﺎﺛﺒﺎﺕ
ﻓﺎﺻﻠﻪ ﻧﻮﮎ ﭘﺮﻩ
ﻻﯾﻪ ﺭﻭﻏﻦ ﻣﺎﻧﻊ ﺍﺯ ﻧﺸﺖ ﮔﺎﺯ ﺩﺭ ﺍﻃﺮﺍﻑ ﻧﻮﮎ ﺁﺏﺑﻨﺪﯼ ﻣﯽﺷﻮﺩ
ﺁﺏﺑﻨﺪﯼ ﻧﻮﮎ ﺷﻨﺎﻭﺭ
ﻭ ﺑﺎ ﺩﻣــﺎﯼ ﭘﺎﯾﯿﻦ ﺗﻀﻤﯿﻦ ﻣﯽﮐﻨﺪ .ﻣﻮﺗﻮﺭ ﺑــﻪ ﻋﻨﻮﺍﻥ ﻣﺎﻧﻌﯽ ﺩﺭ ﺑﺮﺍﺑﺮ ﻫﺮ ﺳﺮﻣﺎﯾﺶ ﻣﺎﯾﻌﯽ ﻋﻤﻞ ﻣﯽﮐﻨﺪ ﮐﻪ ﻣﻤﮑﻦ ﺍﺳﺖ ﺍﺯ ﻃﺮﯾﻖ ﺧﻂ ﻣﮑﺶ ﺑﻪ ﮐﻤﭙﺮﺳــﻮﺭ ،ﺩﺭ ﻫﻨﮕﺎﻡ ﺑﺴــﺘﻪ ﺷﺪﻥ ﺭﻭﺩ ﺑﻪ ﻭﺟﻮﺩ
ﺁﺏﺑﻨﺪﯼ ﺑﺎﺭ ﮔﺎﺯ ﺑﺎ ﻓﺸﺎﺭ ﺑﺎﻻ
ﭘﺮﻩ
ﺁﯾﺪ .ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ﺩﺭ ﭘﻮﺳﺘﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺑﺎﻗﯽ ﻣﯽﻣﺎﻧﺪ .ﺍﺯ ﻟﺤﻈﻪ ﺷﺮﻭﻉ ،ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ﭘﯿﺶ ﺍﺯ ﺭﺳﯿﺪﻥ ﺑﻪ ﻣﺤﻮﻃﻪ ﻣﮑﺶ ﺩﻭﺍﺭ،
ﺗﺼﻮﯾﺮ ) (7ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺑﺎ ﻣﺪﺍﺭ ﮐﻨﺘﺮﻝﺷﺪﻩ ﺍﺯ ﺁﺏﺑﻨﺪﯼﻫﺎﯼ ﺷﻨﺎﻭﺭ ﻧﺼﺐﺷﺪﻩ ﺩﺭ ﺷﯿﺎﺭﻫﺎﯼ ﻧﻮﮎ ﭘﺮﻩ ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ.
ﺍﺯ ﻣﻮﺗﻮﺭ ﻣﯽﮔﺬﺭﺩ .ﻭﺟﻮﺩ ﻣﺎﯾﻊ ،ﺍﻓﺖ ﻓﺸــﺎﺭ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺭﺍ ﺩﺭ ﻣﻮﺗﻮﺭ ﺷــﺪﺕ ﻣﯽﺑﺨﺸــﺪ .ﺍﯾﻦ ﺍﻣﺮ ﺩﺭ ﺗﺮﮐﯿﺐ ﺑﺎ ﺣﺮﺍﺭﺕ ﻣﻮﺗﻮﺭ، ﺑﺎﻋﺚ ﺗﺒﺨﯿﺮ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ﭘﯿﺶ ﺍﺯ ﺭﺳﯿﺪﻥ ﺑﻪ ﺩﻭﺍﺭﻫﺎ ﻣﯽﺷﻮﺩ. ﮔﺎﺯ ﻣﮑﺸــﯽ ﺧﻨﮏ ﻧﯿــﺰ ﻧﯿﺎﺯ ﺑﻪ ﺧﻨﮏ ﺷــﺪﻥ ﺑﯿﺮﻭﻧﯽ ﺭﺍ ﮐﺎﻫﺶ
ﺑﺎ ﻟﻮﻟﻪﮐﺸــﯽ ﺑﻠﻨﺪ ﻭ ﺳــﺮﻣﺎﯾﺶ ﺯﯾﺎﺩ ﺭﺍ ﺍﻣﮑﺎﻥﭘﺬﯾﺮ ﻣﯽﺳﺎﺯﺩ .ﺍﯾﻦ
ﻣﯽﺩﻫﺪ.
ﺷﯿﺮ ﺑﺮﺭﺳﯽ ﺗﺨﻠﯿﻪ
ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﭼﺮﺧﺶ ﻣﻌﮑﻮﺱ
ﺍﺗﺼﺎﻝ ﺗﺨﻠﯿﻪ
ﺩﻭﺍﺭ ﺛﺎﺑﺖ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﭘﻤﭗ ﺭﻭﻏﻦ ،ﺭﻭﻏــﻦﮐﺎﺭﯼ ﯾﺎﺗﺎﻗﺎﻥﻫﺎ ﻭ ﺭﺍﻧﺪﻥ ﺟﻔﺖ ﺩﺭﻭﻥ ﮐﺎﻧﺎﻝ
ﺩﻭﺭﺍﻧــﯽ ﻣﻮﺗﻮﺭ ﺭﺍ ﺗﺒﺪﯾﻞ ﺑﻪ ﺣﺮﮐﺖ ﻣــﺪﺍﺭﯼ ﺩﻭﺍﺭ ﺯﯾﺮﯾﻦ ﻣﯽﮐﻨﺪ.
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺍﺯ ﻧﯿﺮﻭﯼ ﮔﺮﯾﺰﺍﺯﻣﺮﮐﺰ ﺑﺮﺍﯼ ﺑﻪ ﺣﺮﮐﺖ ﺩﺭﺁﻭﺭﺩﻥ
ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ ﮐﻪ ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﯿﻞﻟﻨﮓ ﺷﻨﺎﺧﺘﻪ ﻣﯽﺷﻮﺩ ،ﺣﺮﮐﺖ
ﺟﻌﺒﻪ ﺍﺗﺼﺎﻝ ﻗﻄﻊ ﭼﻨﺪﮔﺎﻧﻪ ﻣﺤﻞ ﺗﺨﻠﯿﻪ
ﯾﺎﺗﺎﻗﺎﻥ ﻓﻮﻗﺎﻧﯽ ،ﻣﺤﻮﺭ ﻭ ﻭﺯﻧﻪ ﺗﻌﺎﺩﻝ
ﺷﯿﺸﻪ ﺑﺮﺭﺳﯽ ﺭﻭﻏﻦ
ﺍﺗﺼﺎﻝ ﻣﮑﺶ
ﺗﻠﻔﻦ55401278 :
ﻣﺤﺎﻓﻆ ﻣﻮﺗﻮﺭ
ﻣﻮﺗﻮﺭ ﻣﺤﻔﻮﻅ 100% ،ﻣﮑﺶ ﮔﺎﺯ ﺧﻨﮏﺷﺪﻩ
ﺻﻔﺤﻪ ﺳﺨﺖ ﻭ ﻣﺠﻤﻮﻋﻪﻫﺎﯼ ﺳﻮﺍﺭﺷﺪﻩ ﺟﺬﺏ ﺍﺭﺗﻌﺎﺵ ﭘﻤﭗ ﮔﺮﯾﺰﺍﺯﻣﺮﮐﺰ ﺭﻭﻏﻦ ﻭ ﯾﺎﺗﺎﻗﺎﻥ ﺯﯾﺮﯾﻦ
ﺗﺼﻮﯾﺮ ) (8ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭﯼ ﮐﺎﻣﻼ ﺷﮕﻔﺖﺍﻧﮕﯿﺰ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ
ﻣﻔﺼﻞ ﺍﻭﻟﺪﻫﺎﻡ
ﺻﻔﺤﻪ / 10ﺷﻤﺎﺭﻩ 30
ﺑﻪ ﺳﻤﺖ ﯾﺎﺗﺎﻗﺎﻥ ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ
ﺍﺗﺼﺎﻝ ﺗﺨﻠﯿﻪ
ﯾﺎﺗﺎﻗﺎﻥ ﻓﻮﻗﺎﻧﯽ
ﻣﺤﻞ ﺩﻭﺭﺍﻥ ﯾﺎﺗﺎﻗﺎﻥ ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ
ﯾﺎﺗﺎﻗﺎﻥ ﻓﻮﻗﺎﻧﯽ ﻧﯿﺮﻭﯼ ﮔﺮﯾﺰﺍﺯﻣﺮﮐﺰ ،ﭘﻤﭗ ﺭﺍ ﺍﺯﻃﺮﯾﻖ ﮐﺎﻧﺎﻝﻫﺎﯾﯽ ﺍﺭﯾﺐ ﺑﻪ ﯾﺎﺗﺎﻗﺎﻥﻫﺎ ﻭ ﻣﺤﻞ ﺩﻭﺍﺭ ﻣﯽﺭﺳﺎﻧﺪ
ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ ﯾﺎﺗﺎﻗﺎﻥ ﺯﯾﺮﯾﻦ
ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ
ﺍﺗﺼﺎﻝ ﻣﮑﺶ ﯾﺎﺗﺎﻗﺎﻥ ﺯﯾﺮﯾﻦ ﻣﻨﺒﻊ ﺭﻭﻏﻦ ﻭﺭﻭﺩﯼ ﺭﻭﻏﻦ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﭘﻤﭗ ﺭﻭﻏﻦ ﮔﺮﯾﺰﺍﺯﻣﺮﮐﺰ
ﺗﺼﻮﯾﺮ ) (9ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﻋﻤﻮﻣﯽ ﮐﻪ ﭘﯿﻮﺳﺘﻪ ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﺨﺰﻥ ﺭﻭﻏﻦ ﺑﺰﺭﮔﯽ ﮐﻪ ﻗﺎﺑﻠﯿﺖ ﺧﻮﺑﯽ ﻓﺮﺍﻫﻢ ﻣﯽﺁﻭﺭﺩ ،ﻋﻤﻞ ﻣﯽﮐﻨﺪ. ﻫﻤﭽﻨﯿﻦ ﻭﺯﻧﻪ ﺗﻌﺎﺩﻝ ﺭﺍ ﮐﻪ ﺩﺭ ﻣﮑﺎﻧﯿﺰﻡ ﮐﻤﭙﺮﺳﻮﺭ ﺿﺮﻭﺭﯼ ﺍﺳﺖ،
ﻧﻮﻉ ﺳــﺮﻣﺎﯾﺶ ،ﺍﺳﺖ .ﺧﻮﺍﺹ ﻫﻨﺪﺳﯽ ﺩﻭﺍﺭ ،ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯾﯽ
ﺗﺤﻤﻞ ﻣﯽﮐﻨﺪ .ﺩﻭ ﯾﺎﺗﺎﻗﺎﻥ ﺑﺎ ﺷــﯿﺎﺭ ﺭﻭﻏﻦﮐﺎﺭﯼﺷﺪﻩ ،ﻣﯿﻞﻟﻨﮓ
ﺑﺎ ﺣﺠﻢ ﺑﯿﺸــﺘﺮ ﭘﯿﻮﺳــﺘﻪ ﺍﻓﺰﺍﯾﺶ ﻣﯽﯾﺎﺑﺪ .ﺩﺭ ﺣﺎﻝ ﺣﺎﺿﺮ ،ﺣﺪ
ﺭﺍ ﺗﻨﻈﯿــﻢ ﻣﯽﮐﻨﻨﺪ ﮐﻪ ﯾﮑﯽ ﺩﺭ ﺯﯾﺮ ﻭ ﺩﯾﮕــﺮﯼ ﺑﺎﻻﯼ ﻣﻮﺗﻮﺭ ﻗﺮﺍﺭ
ﻇﺮﻓﯿﺖ ﻋﻤﻠﯽ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ﺗﮏ 25 ،ﺗﻦ ﺑﻮﺩﻩ ﻭ ﺳــﺎﺯﻧﺪﮔﺎﻥ
ﻣﯽﮔﯿﺮﺩ .ﯾﺎﺗﺎﻗﺎﻥ ﺯﯾﺮﯾﻦ ﺍﺯ ﻧﻈﺮ ﺑﺎﺭﮔﺬﺍﺭﯼ ﺳــﺒﮏ ﺑﻮﺩﻩ ﻭ ﯾﺎﺗﺎﻗﺎﻥ
ﺳﻌﯽ ﺩﺭ ﺭﺳﯿﺪﻥ ﺑﻪ ﻣﯿﺰﺍﻧﯽ ﺑﯿﺶ ﺍﺯ ﺁﻥ ﻧﯿﺰ ﺩﺍﺭﻧﺪ.
ﻓﻮﻗﺎﻧﯽ ،ﺑﺎﺭ ﻣﺠﻤﻮﻋﻪ ﺗﺮﺍﮐﻢ ﺭﺍ ﺗﺤﻤﻞ ﻣﯽﮐﻨﺪ.
ﺁﺏﺑﻨﺪﯼﻫﺎ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺑﺎ ﻣــﺪﺍﺭ ﮐﻨﺘﺮﻝﺷــﺪﻩ ،ﺩﺭ ﻧﻮﮎ ﭘﺮﻩﻫﺎ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺩﻭﺍﺭﻫﺎ ﺩﻭﺍﺭﻫﺎ ﺍﺯ ﻗﻄﻌﺎﺗﯽ ﮐﻪ ﺑﻪ ﺷــﮑﻞ ﺍﻭﻟﯿﻪ ﺩﻭﺍﺭ ﻭ ﺍﺯ ﺟﻨﺲ ﻓﻮﻻﺩ
ﺁﺏﺑﻨﺪﯼﻫﺎﯾﯽ ﺩﺍﺭﻧﺪ .ﻣﻌﻤﻮﻻ ﺩﻭ ﻧﻮﻉ ﺁﺏﺑﻨﺪﯼ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ.
ﮐﺮﺑﻨﯽ ﻫﺴﺘﻨﺪ ،ﺳﺎﺧﺘﻪ ﻣﯽﺷﻮﻧﺪ .ﻣﺎﺷﯿﻦﮐﺎﺭﯼ ﺁﻥﻫﺎ ﺑﻪ ﻭﺳﯿﻠﻪ
ﺩﺭ ﻧﺨﺴــﺘﯿﻦ ﺣﺎﻟــﺖ ،ﻧﻮﺍﺭﻫﺎﯾﯽ ﻓﻠــﺰﯼ ،ﺑﺎﺭﯾــﮏ ﻭ ﭼﻨﺪﺗﺎﯾﯽ ﺑﺎ
ﺍﺑﺰﺍﺭﯼ ﺑﺎ ﺳــﺮﻋﺖ ﺑﺎﻻ ﻭ ﺑﺎ ﮐﻨﺘﺮﻝ ﮐﺎﻣﭙﯿﻮﺗﺮﯼ ﺍﻧﺠﺎﻡ ﻣﯽﺷــﻮﺩ ﺗﺎ
ﺻﻔﺤﺎﺗﯽ ﺩﺭ ﮐﻨﺎﺭ ﻫﻢ ،ﻧﺼﺐ ﻣﯽﺷــﻮﻧﺪ )ﺗﺼﻮﯾﺮ .(10ﺩﺭ ﺩﻭﻣﯿﻦ
ﺳﻄﺢ ﻫﻨﺪﺳﯽ ﺩﻗﯿﻘﯽ ﺑﺮﺍﯼ ﺧﻠﻖ ﻣﺎﺭﭘﯿﭻﻫﺎﯼ ﻣﻮﺭﺩ ﻧﻈﺮ ﭘﺪﯾﺪ ﺁﯾﺪ.
ﺣﺎﻟﺖ ،ﺟﺰﯾﯽ ﮔﺮﺍﻓﯿﺘﯽ ﺩﺭﻭﻥ ﻧﻮﮎ ﺷﯿﺎﺭ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ .ﺩﺭ ﻫﺮ ﺩﻭ
ﺗﺠﻬﯿﺰﺍﺕ ﻓﻠﺰﮐﺎﺭﯼ ﺟﺪﯾﺪ ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﮐﻨﺘﺮﻝﻫﺎﯼ ﺩﯾﺠﯿﺘﺎﻝ،
ﻣﻮﺭﺩ ،ﺷــﻨﺎﻭﺭ ﺑﻮﺩﻥ ﺟﺰﻭ ﺁﺏﺑﻨﺪﯼ ﺩﺭ ﻧﻮﮎ ﺷﯿﺎﺭ ﺑﻪ ﻃﻮﺭ ﻣﻮﺛﺮﯼ
ﺩﻗــﺖ ﻻﺯﻡ ﺭﺍ ﻫﻤــﺮﺍﻩ ﺑﺎ ﮐﯿﻔﯿــﺖ ﺑﺎﻻﯼ ﭘﺮﺩﺍﺧﺖ ﺳــﻄﻮﺡ ﺍﺭﺍﺋﻪ ﻣﯽﮐﻨﻨﺪ )ﻓﺎﺻﻠﻪ ﺑﺎﻗﯽﻣﺎﻧﺪﻩ ،ﻣﯿﮑﺮﻭﻣﺘﺮ Ra ^ 0.7ﺍﺳﺖ(. ﯾﺎﺗﺎﻗﺎﻥ ،ﺿﺮﺑﻪ ﻫﯿﺪﺭﻭﺩﯾﻨﺎﻣﯿﮏ ﺩﻭﺍﺭ ﻣﺘﺤﺮﮎ ﺭﺍ ﺗﺤﻤﻞ ﮐﺮﺩﻩ
ﺑــﻪ ﺁﺏﺑﻨﺪﯼ ﺍﻣﮑﺎﻥ ﯾﮏﭘﺎﺭﭼﮕﯽ ﺯﯾﺎﺩﯼ ﺭﺍ ﺩﺭ ﺗﻐﯿﯿﺮﺍﺕ ﭘﯿﻮﺳــﺘﻪ ﺩﻣﺎ ﻭ ﻓﺸﺎﺭ ﻣﯽﺩﻫﺪ.
ﺣﻔﺎﻇﺖ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭ
ﻭ ﺩﺭﺑﺮﺍﺑﺮ ﻧﯿﺮﻭﯼ ﻣﺤﻮﺭﯼ ﮔﺎﺯ ﻣﺘﺮﺍﮐﻢﺷــﺪﻩ ﺑﯿﻦ ﺩﻭﺍﺭﻫﺎ ﻣﻘﺎﻭﻣﺖ
ﺑﻪ ﻃﻮﺭ ﻧﻈﺮﯼ ﺣﻔﺎﻇﺖ ﺍﺯ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ،ﺳﺮﺭﺍﺳــﺖ ﺑﻮﺩﻩ
ﻣﯽﮐﻨﺪ .ﻃﺮﺍﺣﯽ ﺩﻗﯿــﻖ ﯾﺎﺗﺎﻗﺎﻥ ﻭ ﺍﻧﺘﺨﺎﺏ ﺭﻭﻏﻦﮐﺎﺭﯼ ،ﺍﻫﻤﯿﺖ
ﻭ ﻧﯿﺎﺯﯼ ﺑﻪ ﺍﻟﺰﺍﻣﺎﺕ ﺩﯾﮕﺮ ﺍﻧﻮﺍﻉ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎ ﻧﺪﺍﺭﺩ .ﺩﺭﺣﻘﯿﻘﺖ،
ﺯﯾﺎﺩﯼ ﺩﺭ ﺍﻓﺰﺍﯾﺶ ﮐﺎﺭﺍﯾﯽ ﮐﻤﭙﺮﺳﻮﺭ ﺩﺍﺭﺩ.
ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺑﺎﯾــﺪ ﺩﺭﺑﺮﺍﺑﺮ ﻓﺸــﺎﺭ ﺑﯿــﺶ ﺍﺯ ﺣﺪ ،ﮔﺮﻣﺎﯼ
ﻃﺮﺍﺣﯽ ﺩﻭﺍﺭ ﺷــﺎﻣﻞ ﻣﺸــﺨﺼﺎﺕ ﻗﻄﺮ ﻭ ﺍﺭﺗﻔﺎﻉ ﺁﻥ ﺑﺮﺍﯼ ﻫﺮ ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺑﯿﺶ ﺍﺯ ﺣﺪ ،ﭼﺮﺧﺶ ﻣﻌﮑﻮﺱ ﻭ ﺿﺮﺑﻪ ،ﻣﺤﺎﻓﻈﺖ ﺷــﻮﻧﺪ .ﮐﺮﯾﺮ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 11ﺷﻤﺎﺭﻩ 30
ﻣﺤﺎﻓﻈﺖ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﺭﺍ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺻﻔﺤﻪ ﻣﺤﺎﻓﻈﯽ ﮐﻪ ﺑﺮ ﭘﻮﺳﺘﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺳﻮﺍﺭ ﻣﯽﺷﻮﺩ ،ﺍﻧﺠﺎﻡ ﻣﯽﺩﻫﺪ.
ﺟﺮﯾﺎﻥ ﺑﺮﮔﺸﺘﯽ ﭘﺪﯾﺪ ﻣﯽﺁﻭﺭﺩ. ﻭﻗﺘﯽ ﮐﻤﭙﺮﺳﻮﺭ ﻣﺘﻮﻗﻒ ﻣﯽﺷــﻮﺩ ،ﮔﺎﺯ ﺑﻪﺩﺍﻡﺍﻓﺘﺎﺩﻩ ﺑﺎ ﻓﺸﺎﺭ ﺑــﺎﻻ ﺩﺭ ﺑﺴــﺘﻪﻫﺎﯼ ﻫﻼﻟﯽ ،ﺑﯿﻦ ﺩﻭﺍﺭﻫﺎ ﺑﻪ ﺑﺨﺶ ﻣﮑﺶ ﻧﺸــﺖ
ﺳﻮﯾﯿﭻ ﻓﺸﺎﺭ ﺑﺎﻻ ﺳﻮﯾﯿﭻﻫﺎﯼ ﻓﺸــﺎﺭ ﺑﺎﻻ ﺗﺠﻬﯿﺰﺍﺗﯽ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ﺑــﻮﺩﻩ ﻭ ﺑﺎﯾــﺪ ﺑﺎ ﺍﻟﺰﺍﻣــﺎﺕ ،ULﻣﻄﺎﺑﻘﺖ ﺩﺍﺷــﺘﻪ ﺑﺎﺷــﻨﺪ .ﺩﺭ ﺳﯿﺴﺘﻤﯽ ﺑﺎ ﭼﻨﺪ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸﯽ ﻣﺎﻧﻨﺪ ﭼﯿﻠﺮ ﻫﻮﺍﺳﺮﺩ ،ﻫﺮ ﻣﺪﺍﺭ ﺑﺎﯾﺪ ﺳــﻮﯾﯿﭻ ﻓﺸــﺎﺭ ﺑﺎﻻﯼ ﻣﺠﺰﺍﯾﯽ ﺑﺮﺍﯼ ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﻓﺸﺎﺭ ﺑﯿﺶ ﺍﺯ ﺣﺪ ﺩﺍﺷــﺘﻪ ﺑﺎﺷﺪ .ﺳــﻮﯾﯿﭻﻫﺎ ﺑﺎﯾﺪ ﺑﻪ ﺻﻮﺭﺕ ﺳﺮﯼ ﻗﺮﺍﺭ
ﻣﯽﮐﻨﺪ .ﺍﯾﻦ ﺍﻣﺮ ﺑﻪ ﮐﻤﭙﺮﺳــﻮﺭ ﺍﻣﮑﺎﻥ ﺷﺮﻭﻉ ﺑﺪﻭﻥ ﺑﺎﺭﮔﺬﺍﺭﯼ ﺭﺍ ﺩﺍﺩﻩ ﻭ ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﺗﻨﺶﻫﺎﯼ ﻣﮑﺎﻧﯿﮑﯽ ،ﮔﺸــﺘﺎﻭﺭ ﻭ ﺟﺮﯾﺎﻥ ﺩﺭ ﻫﻨﮕﺎﻡ ﺁﻏﺎﺯﺑﻪﮐﺎﺭ ﺁﻥ ﻣﯽﺷﻮﺩ.
ﻫﯿﺘﺮ ﻣﺤﻔﻈﻪ ﻣﯿﻞﻟﻨﮓ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ﻣﻤﮑﻦ ﺍﺳﺖ ﺩﺭ ﻣﺨﺰﻥ ﺭﻭﻏﻦ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ
ﮔﯿﺮﻧﺪ ﺗﺎ ﻓﺸﺎﺭ ﺑﺎﻻ ،ﺗﻤﺎﻡ ﺳﯿﺴﺘﻢ ﺭﺍ ﻣﺘﻮﻗﻒ ﮐﻨﺪ.
ﺩﻭﺍﺭ ﺟﻤﻊ ﺷــﻮﺩ .ﺑﺮﺍﯼ ﺍﺟﺘﻨﺎﺏ ﺍﺯ ﺿﺮﺑﻪ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ﺩﺭﻭﻥ
ﺣﺪ ﻓﺸﺎﺭ ﺑﺎﻻ
ﮐﻤﭙﺮﺳﻮﺭ ﻭ ﺩﺭ ﻫﻨﮕﺎﻡ ﺁﻏﺎﺯﺑﻪﮐﺎﺭ ﺁﻥ ،ﺳﺎﺯﻧﺪﮔﺎﻥ ﺑﻪ ﻃﻮﺭ ﺳﻨﺘﯽ ﺍﺯ
ﺩﺍﺧﻠﯽ ﺑﻮﺩﻩ ﻭ ﺑﻪ ﮔﻮﻧﻪﺍﯼ ﻧﺼﺐ ﻣﯽﺷﻮﺩ ﮐﻪ ﺩﻣﺎﯼ ﻣﻮﺗﻮﺭ ﻭ ﺩﻣﺎﯼ
ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸــﯽ )ﻧﻪ ﺭﻭﻏﻦ( ﻣﯽﺷﻮﺩ ﺗﺎ ﺩﺭ ﻟﺤﻈﻪ ﺷﺮﻭﻉ ﺗﻨﻬﺎ ﮔﺎﺯ
ﮔﺎﺯ ﺗﺨﻠﯿﻪ ﺭﺍ ﮐﻨﺘﺮﻝ ﮐﻨــﺪ .ﺍﻓﺰﺍﯾﺶ ﺩﻣﺎ ﺗﺎ 220ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ
ﺳﺮﻣﺎﯾﺸﯽ ﻭﺟﻮﺩ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ .ﺩﺭ ﺍﯾﻦ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ،ﻫﯿﺘﺮ
) 104ﺩﺭﺟﻪ ﺳــﺎﻧﺘﯽﮔﺮﺍﺩ( ﺑﺎﻋﺚ ﻓﻌﺎﻝ ﺷﺪﻥ ﺳﻮﯾﯿﭻ ﻭ ﺧﺎﻣﻮﺷﯽ
ﺑﺮ ﺍﻧﺘﻬﺎﯼ ﭘﻮﺳﺘﻪ ﻭ ﺩﺭ ﺑﺨﺶ ﺧﺎﺭﺟﯽ ﻧﺼﺐ ﻣﯽﺷﻮﺩ.
ﮐﻤﭙﺮﺳﻮﺭ ﻣﯽﺷﻮﺩ.
ﺩﯾﮕﺮ ﻣﻮﺍﺭﺩ ﻣﺤﺎﻓﻈﺖ ﮐﻤﭙﺮﺳﻮﺭ ﻣﺤﺎﻓﻈﺖ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭ ﻫﻤﯿﺸﻪ ﺑﻪ ﺻﻮﺭﺕ ﺩﺍﺧﻠﯽ ﻧﯿﺴﺖ .ﮐﺮﯾﺮ
ﺷﯿﺮ ﺗﺨﻠﯿﻪ ﯾﮏ ﺷﯿﺮ ﺗﺨﻠﯿﻪ ﺑﺮ ﺍﺗﺼﺎﻝ ﺗﺨﻠﯿﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺳﻮﺍﺭ ﺷﺪﻩ )ﻧﺰﺩﯾﮏ
ﺳــﻄﻮﺡ ﻣﺤﺎﻓﻆ ﺧﺎﺭﺟﯽ ﺭﺍ ﺑﺮﺍﯼ ﺍﻃﻤﯿﻨﺎﻥ ﺍﺯ ﻋﻤﻠﮑﺮﺩ ﻣﻄﻤﺌﻦ ﻭ
ﺑﺎﻻﯼ ﭘﻮﺳﺘﻪ ﮐﻤﭙﺮﺳﻮﺭ( ﻭ ﻣﺎﻧﻊ ﺍﺯ ﭼﺮﺧﺶ ﻣﻌﮑﻮﺱ ﮐﻤﭙﺮﺳﻮﺭ ﺩﺭ
ﺍﯾﻤﻦ ﮐﻤﭙﺮﺳﻮﺭ ،ﺍﻓﺰﻭﺩﻩ ﺍﺳﺖ .ﺑﺮﺍﯼ ﻧﻤﻮﻧﻪ ﺩﺭ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﺳﺮﺩ
ﺯﻣﺎﻥ ﺧﺎﻣﻮﺷﯽ ﻣﯽﺷﻮﺩ .ﻭﺟﻮﺩ ﺷﯿﺮﯼ ﺧﺎﺭﺟﯽ ﺑﺎﻋﺚ ﺍﻓﺖ ﻓﺸﺎﺭ
،Aqua Snapﻣﺤﺎﻓﻈــﺖ ﺩﻭﺍﺭ ﺩﺍﺭﺍﯼ ﺻﻔﺤــﻪ ﻣﺪﺍﺭﯼ ﺍﺭﺗﺒﺎﻃﯽ
ﮐﻤﺘﺮﯼ ﻧﺴــﺒﺖ ﺑﻪ ﺷﯿﺮ ﺩﺍﺧﻠﯽ ﺷﺪﻩ ﻭ ﻣﺤﺎﻓﻈﺖ ﺑﻬﺘﺮﯼ ﺩﺭﺑﺮﺍﺑﺮ
ﺍﺳــﺖ ﮐﻪ ﺑﻪ ﻃﻮﺭ ﻣﺴﺘﻤﺮ ﺍﻃﻼﻋﺎﺕ ﻋﻤﻠﯿﺎﺗﯽ ﺭﺍ ﺑﺎ ﺻﻔﺤﻪ ﮐﻨﺘﺮﻝ ﺍﺻﻠــﯽ ﭼﯿﻠﺮ ،ﻣﺒﺎﺩﻟﻪ ﻣﯽﮐﻨﺪ .ﻋﻨﺎﺻﺮ ﻧﺮﻡﺍﻓﺰﺍﺭﯼ ،ﺷــﺎﻣﻞ ﻣﻮﺍﺭﺩ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻓﺸــﺎﺭ ﺑــﺎﻻ ،ﻣﺤﺎﻓﻈﺖ ﻣﯽﮐﻨﺪ .ﺩﺭ ﺍﯾﻦ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎ ،ﺣﺴــﮕﺮ
ﺍﻧــﺮﮊﯼ ﻣﯽﮔﯿﺮﺩ .ﻫﯿﺘﺮ ﻣﺨﺰﻥ ﺭﻭﻏﻦ ﺭﺍ ﮔﺮﻡ ﻭ ﺑﺎﻋﺚ ﺟﻮﺷــﺎﻧﺪﻥ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺣﺴــﮕﺮ ﺩﺍﺧﻠﯽ ﻓﺸﺎﺭ ،ﮐﻤﭙﺮﺳــﻮﺭ ﺭﺍ ﺩﺭﺑﺮﺍﺑﺮ ﺧﻄﺮ ﺍﺣﺘﻤﺎﻟﯽ
ﻫﯿﺘﺮﯼ ﺍﻟﮑﺘﺮﯾﮑﯽ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﮐﻨﻨﺪ ﮐﻪ ﺩﺭ ﻫﻨﮕﺎﻡ ﺗﻮﻗﻒ ﮐﻤﭙﺮﺳﻮﺭ
ﺯﯾﺮ ﺭﺍ ﺑﺮﺍﯼ ﻣﺤﺎﻓﻈﺖ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭ ﺍﺳﺖ: ﺻﻔﺤﻪ ﭘﺎﯾﻪ ﺩﻭﺍﺭ ﻣﻘﺎﺑﻞ ﻓﺎﺻﻠﻪ ﻧﻮﮎ ﭘﺮﻩ
ﻓﺎﺯ ،ﺳﯿﺴــﺘﻢ ﮐﻨﺘﺮﻝ ﭼﯿﻠﺮ ،ﻣﻨﺒﻊ ﻧﯿﺮﻭ ﺭﺍ ﻗﻄﻊ ﻣﯽﮐﻨﺪ .ﮐﺎﻫﺶ ﻓﺎﺯ ﺩﺭ ﺳﯿﺴــﺘﻢ ﺳﻪﻓﺎﺯ ،ﺑﺎﻋﺚ ﭼﺮﺧﺶ ﻣﻌﮑﻮﺱ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ﻣﯽﺷﻮﺩ.
ﺁﺏﺑﻨﺪﯼ ﻧﻮﮎ ﭼﻨﺪﻻﯾﻪ
ﻣﺤﺎﻓﻈﺖ ﺩﺭ ﻟﺤﻈﻪ ﺷﺮﻭﻉ :ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺍﻃﻼﻋﺎﺕ ﺩﺍﺩﻩﺷﺪﻩ ﺍﺯ ﻭﺍﺣﺪ ﺑﺮﺭﺳﯽ ﺍﻃﻼﻋﺎﺕ ،ﺳﯿﺴﺘﻢ ﮐﻨﺘﺮﻝ ﭼﯿﻠﺮ ،ﻓﺸﺎﺭ ﺗﺨﻠﯿﻪ ﺩﺭ
ﭘﺮﻩ
ﻧﺨﺴﺘﯿﻦ ﺛﺎﻧﯿﻪﻫﺎﯼ ﺷﺮﻭﻉ ﻭ ﻣﮑﺶ ﮐﻤﭙﺮﺳﻮﺭ ﺭﺍ ﺗﺤﺖ ﻧﻈﺮ ﺩﺍﺭﺩ. ﻃﺮﺍﺣﯽ ﺟﺰﻭ ﭼﻨﺪﮔﺎﻧﻪ
ﺗﻠﻔﻦ55401278 :
ﻃﺮﺍﺣﯽ ﺟﺰﻭ ﺗﮏ
ﻣﺴﺘﻤﺮ ،ﻣﻨﺒﻊ ﺳــﻪﻓﺎﺯ ﻭﺭﻭﺩﯼ ﺭﺍ ﺑﺮﺭﺳﯽ ﻣﯽﮐﻨﺪ .ﺑﺎ ﮐﺎﻫﺶ ﻫﺮ
ﺍﮔﺮ ﮐﻤﭙﺮﺳــﻮﺭ ﻧﺘﻮﺍﻧﺪ ﺑﻪ ﻓﺸــﺎﺭ ﺗﻔﺎﺿﻠﯽ ﻣﻮﺭﺩ ﻧﻈﺮ ﺑﺮﺳﺪ )ﻓﺸﺎﺭ ﺗﺨﻠﯿﻪ ﮐﻤﺘﺮ ﺍﺯ 10psigﮐﺎﻫﺶ ﻣﯽﯾﺎﺑﺪ( ﯾﺎ ﺩﺭﺻﻮﺭﺗﯽ ﮐﻪ ﻓﺸــﺎﺭ
ﺗﺼﻮﯾﺮ ) (10ﺁﺏﺑﻨﺪﯼ ﻧﻮﮎ ﭘﺮﻩ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﮐﻨﺘﺮﻝﺷﺪﻩ ،ﻣﺤﯿﻂ ﺗﻤﺎﺱ ﻭ ﺍﺻﻄﮑﺎﮎ ﮐﻤﺘﺮﯼ ﻧﺴﺒﺖ ﺑﻪ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺗﻄﺒﯿﻘﯽ ﮐﻪ ﻧﻮﮎ ﭘﺮﻩ ﻭ ﭘﺎﯾﻪ ﺩﻭﺍﺭ ﻣﻘﺎﺑﻞ ﺑﺎ ﻫﻢ ﺩﺭ ﺗﻤﺎﺱﺍﻧﺪ ،ﺩﺍﺭﻧﺪ. ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﺨﻠﯿﻪ ﮐﺎﻫﺶ ﯾﺎﺑﺪ ،ﮐﻤﭙﺮﺳﻮﺭ ﻣﺘﻮﻗﻒ ﻣﯽﺷﻮﺩ. ﺷﺮﻭﻉ ﺑﯿﺶ ﺍﺯ ﺣﺪ :ﭼﺮﺧﻪ ﺭﻭﺷﻦ ﻭ ﺧﺎﻣﻮﺵ ﭼﯿﻠﺮ ﺩﺭ ﺍﺭﺗﺒﺎﻁ ﺑﺎ ﺩﻣﺎﯼ ﺁﺏ ﺧﻨﮏﺷﺪﻩ ﺍﺳﺖ .ﻧﺮﻡﺍﻓﺰﺍﺭ ﮐﻨﺘﺮﻝ ﭼﯿﻠﺮ Aqua Snap ﺑﻪ ﺻﻮﺭﺕ ﺧﻮﺩﮐﺎﺭ ،ﺳﯿﺴــﺘﻢ ﺭﺍ ﺑﺎ ﻭﺿﻌﯿﺖ ﺗﻄﺒﯿﻖ ﻣﯽﺩﻫﺪ .ﺍﯾﻦ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺁﺏﺑﻨﺪﯼ ﻧﻮﮎ ﮔﺮﺍﻓﯿﺘﯽ، ﺟﺰﻭ ﺗﮏ ﻓﺸﺎﺭ ﺑﺎﺭ ﺁﺏﺑﻨﺪﯼ ،ﺩﺭ ﺷﯿﺎﺭ ﺷﻨﺎﻭﺭ ﺷﺪﻩ ﺗﺎ ﺗﻤﺎﺱ ﭘﯿﻮﺳﺘﻪ ﻣﺘﺤﺮﮎ ﺑﺎ ﺣﺪﺍﻗﻞ ﺍﺻﻄﮑﺎﮎ ﺻﻮﺭﺕ ﭘﺬﯾﺮﺩ
ﻣﺤﺎﻓﻈـﺖ ﺗﮏﻓـﺎﺯ :ﺻﻔﺤﻪ ﮐﻨﺘــﺮﻝ ﺍﺻﻠﯽ ﭼﯿﻠــﺮ ﺑﻪ ﻃﻮﺭ
ﺻﻔﺤﻪ / 12ﺷﻤﺎﺭﻩ 30
ﺍﻣﺮ ﺑﺎﻋﺚ ﻣﯽﺷــﻮﺩ ﺗﺎ ﮐﻤﭙﺮﺳــﻮﺭ ﻫﺮﮔﺰ ﺑﯿــﺶ ﺍﺯ ﺩﻭﺍﺯﺩﻩ ﺑﺎﺭ ﺩﺭ
ﻭ ﻣﻮﻗﻌﯿﺖﻫﺎﯼ ﻧﺴــﺒﯽ ﺑﺨﺶﻫﺎﯼ ﻣﮑﺶ ﻭ ﺗﺨﻠﯿﻪ ﺩﺍﺭﺩ .ﺍﮔﺮ ﺍﯾﻦ
ﺳﺎﻋﺖ ،ﺭﻭﺷﻦ ﻧﺸﻮﺩ .ﺭﻭﺷﻦ ﺷﺪﻥ ﺑﯿﺶ ﺍﺯ ﺣﺪ ﺑﺎﻋﺚ ﮔﺮﻡ ﺷﺪﻥ
ﻭﺍﺣﺪﻫــﺎ ﺩﺭ ﺩﻭ ﺳــﻤﺖ ﻣﻘﺎﺑﻞ ﭘﺮﻭﺍﻧﻪﻫﺎ ﺑﺎﺷــﻨﺪ )ﺑﺪﻭﻥ ﻣﺠﺎﺭﯼ
ﺯﯾﺎﺩ ﻣﻮﺗﻮﺭ ﻣﯽﺷﻮﺩ.
ﻣﯿﺎﻧﯽ( ﮐﻤﭙﺮﺳــﻮﺭ ﺑﺎ ﻇﺮﻓﯿﺖ ﮐﺎﻣــﻞ ﺟﺎﺑﻪﺟﺎﯾﯽ ﻋﻤﻞ ﻣﯽﮐﻨﺪ.
ﻋﻮﺍﻣﻞ ﻣﻮﺛﺮ ﺑﺮ ﻋﻤﻠﮑﺮﺩ ﮐﻤﭙﺮﺳـﻮﺭ :ﻫﺮ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭﯼ، ﻋﻮﺍﻣــﻞ ﻣﻮﺛﺮﯼ ﺑﺮ ﻋﻤﻠﮑﺮﺩ ﺩﺍﺭﺩ ﮐﻪ ﺷــﺎﻣﻞ ﺗﺮﮐﯿﺐ ﻗﺎﺑﻞ ﻗﺒﻮﻟﯽ ﺍﺯ ﻓﺸــﺎﺭ ﻣﮑــﺶ ﻭ ﺗﺨﻠﯿﻪ )ﺩﻣﺎﯼ ﺗﺨﻠﯿﻪ ﻭ ﻣﮑﺶ( ﻣﯽﺷــﻮﺩ ﮐﻪ ﺑﺮﺍﯼ ﻋﻤﻠﮑﺮﺩ ﭘﯿﻮﺳﺘﻪ ﻭ ﻣﻄﻤﺌﻦ ،ﻃﺮﺍﺣﯽ ﺷﺪﻩ ﺍﺳﺖ .ﻋﻤﻠﮑﺮﺩﯼ
ﺍﯾﻦ ﺷــﯿﺮﻫﺎ ﺩﺭ ﻃــﻮﻝ ﯾﮏ ﯾﺎ ﻫﺮ ﺩﻭ ﺣﻔﺮﻩ ﻣﻮﺗﻮﺭ ﺑﺎﺯ ﻣﯽﺷــﻮﻧﺪ.
ﺧﺎﺭﺝ ﺍﺯ ﻋﻮﺍﻣﻞ ﻗﺎﺑﻞ ﻗﺒﻮﻝ ،ﺑﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺻﺪﻣﻪ ﻣﯽﺯﻧﺪ .ﺳﯿﺴﺘﻢ
ﻭﻗﺘﯽ ﺗﻤﺎﻡ ﺷﯿﺮﻫﺎ ﺑﺴﺘﻪﺍﻧﺪ ،ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺧﻂ ﻣﻌﻤﻮﻝ ﺗﺮﺍﮐﻢ ﺭﺍ
ﮐﻨﺘــﺮﻝ ﭼﯿﻠــﺮ Aqua Snapﻋﻮﺍﻣﻠﯽ ﺩﺍﺭﺩ ﮐﻪ ﺑﻪ ﻋﻨﻮﺍﻥ ﻧﻘﺸــﻪ
ﺍﺯ ﻣﺤﻞ ﻣﮑﺶ ﺗﺎ ﻣﺤﻞ ﺗﺨﻠﯿﻪ ﻃﯽ ﮐﺮﺩﻩ ﻭ ﮐﻤﭙﺮﺳــﻮﺭ ﺑﺎ ﻇﺮﻓﯿﺖ
ﻋﻤﻠﯿﺎﺗﯽ ﺩﺭ ﻧﺮﻡﺍﻓﺰﺍﺭ ﺁﻥ ﻣﺸﺨﺺ ﺷﺪﻩﺍﻧﺪ .ﺳﯿﺴﺘﻢ ﮐﻨﺘﺮﻝ ﭼﯿﻠﺮ
ﮐﺎﻣﻞ ﻋﻤﻞ ﻣﯽﮐﻨﺪ .ﺑﺎﺯﮐﺮﺩﻥ ﻧﺨﺴــﺘﯿﻦ ﺷــﯿﺮ )ﻧﺰﺩﯾﮏ ﻣﺠﺮﺍﯼ
ﺍﺯ ﺍﯾﻦ ﻧﻘﺸــﻪ ﻋﻤﻠﯿﺎﺗﯽ ﺩﺭ ﻣﺮﺍﺣﻞ ﺭﻭﺷــﻦ ﻭ ﺧﺎﻣﻮﺵ ﮐﻤﭙﺮﺳﻮﺭ
ﻣﮑﺶ( ﮐﺎﺭﺍﯾﯽ ﺭﺍ ﮐﺎﻫﺶ ﻭ ﺁﻏﺎﺯ ﺗﺮﺍﮐﻢ ﺭﺍ ﺗﺎ ﻧﻘﻄﻪﺍﯼ ﭘﺎﯾﯿﻦ ﺷــﯿﺮ
ﻫﻤﺮﺍﻩ ﺑﺎ ﻋﻮﺍﻣﻞ ﻗﺎﺑﻞ ﻗﺒﻮﻝ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﮐﻨﺪ ﻭ ﺑﻪ ﻃﻮﺭ ﭘﯿﻮﺳﺘﻪ،
ﺑﺎﺯ ،ﺑﻪ ﺗﺎﺧﯿﺮ ﻣﯽﺍﻧﺪﺍﺯﺩ .ﺗﺮﺍﮐﻢ ﺗﺎ ﺯﻣﺎﻧﯽ ﮐﻪ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﯿﻦ
ﺗﻤﺎﻡ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸﯽ ﺭﺍ ﺯﯾﺮ ﻧﻈﺮ ﺩﺍﺭﺩ.
ﺷــﺒﮑﻪﻫﺎ ﺑﻪ ﺩﺍﻡ ﺍﻓﺘﺎﺩﻩ ﻭ ﮐﻤﭙﺮﺳــﻮﺭ ﺷــﺮﻭﻉ ﺑﻪ ﮐﺎﺭ ﮐﻨﺪ ،ﺁﻏﺎﺯ ﻧﺨﻮﺍﻫﺪ ﺷﺪ .ﻇﺮﻓﯿﺖ ﮐﻤﭙﺮﺳــﻮﺭ ﺑﺴﺘﮕﯽ ﺑﻪ ﺷﯿﺮﻫﺎﯼ ﺑﺎﻻﺭﻭﻧﺪﻩ
ﺩﻭ ﻧﺤﻮﻩ ﻧﮕﺮﺵ ﺩﺭﺑﺎﺭﻩ ﮐﻤﭙﺮﺳــﻮﺭ ﻭﺟــﻮﺩ ﺩﺍﺭﺩ (a :ﮐﺎﺭﺍﯾﯽ ﺗﺮﻣﻮﺩﯾﻨﺎﻣﯿﮏ ﻭ ﻣﺴﺘﻘﻞ ﺧﻮﺩ ﮐﻤﭙﺮﺳﻮﺭ (bﮐﺎﺭﺍﯾﯽ ﮐﻤﭙﺮﺳﻮﺭ ﺩﺭ ﺳﯿﺴﺘﻢ .ﺭﻭﺵ ﻧﺨﺴــﺖ ﻣﻌﯿﺎﺭ ﻣﻔﯿﺪﯼ ﺑﺮﺍﯼ ﻃﺮﺍﺣﺎﻥ ﮐﻤﭙﺮﺳﻮﺭ ﺍﺳــﺖ.ﺭﻭﺵ ﺩﻭﻡ ﺍﻫﻤﯿﺖ ﺑﯿﺸــﺘﺮﯼ ﺑﺮﺍﯼ ﻣﺎﻟﮑﺎﻥ ﺑﻨﺎ ﻭ ﻃﺮﺍﺣﺎﻥ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺩﺍﺭﺩ. ﻃﺮﺍﺣﺎﻥ ﮐﻤﭙﺮﺳﻮﺭ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺑﺮﺍﯼ ﻫﺮ ﺳﺮﻣﺎﯾﺶ ﺧﺎﺹ ﻭ ﺑﺮ ﺍﺳــﺎﺱ ﻋﻤﻠﮑﺮﺩ ﮐﻤﭙﺮﺳــﻮﺭ ،ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ .ﺗﻐﯿﯿﺮﺍﺕ ﺩﺭ ﻫﻨﺪﺳــﻪ ﺩﻭﺍﺭ ،ﻃﺮﺡ ﭘﻮﺳــﺘﻪ ،ﺍﻧﺘﺨﺎﺏ ﺭﻭﻏﻦ ﻭ ﺩﯾﮕﺮ ﻣﻮﺍﺭﺩ، ﺗﺮﮐﯿﺐ ﺳﺮﻣﺎﯾﺸﯽ ﮐﻤﭙﺮﺳﻮﺭ ﺭﺍ ﺑﻬﺒﻮﺩ ﻣﯽﺑﺨﺸﺪ. ﻃﺮﺍﺣــﺎﻥ ﭼﯿﻠــﺮ ﺑــﺮ ﮐﺎﺭﺍﯾــﯽ ﻫﻤــﻪ ﺳﯿﺴــﺘﻢ ﺗﻤﺮﮐــﺰ ﻣﯽﮐﻨﻨــﺪ .ﭼﯿﻠــﺮ ﻫﻮﺍﯾــﯽ Aqua Snapﻣــﺪﻝ RB 30 ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﮐﺮﯾــﺮ ﺑــﺎ A 410 - Rﻋﻤﻞ ﮐــﺮﺩﻩ ﻭ ﺑﺎﺭ ﮐﺎﻣــﻞ ،EERﻣﻘﺪﺍﺭ 9.6ﺗــﺎ Btu/hr.W 9.9) 1.21ﺗــﺎ ( Kw/ton 1.25ﻭ ﻣﻘﺪﺍﺭ ﺗﻠﻔﻦ88739880-2:
ﻇﺮﻓﯿﺖ ﺁﻥ ﺍﺳﺖ. ﺷﯿﺮﻫﺎﯼ ﺑﺎﻻﺭﻭﻧﺪﻩ ﺩﺭ ﻣﺮﺍﺣﻠﯽ ،ﺟﺎﺑﻪﺟﺎﯾﯽ ﺭﺍ ﺗﻨﻈﯿﻢ ﻣﯽﮐﻨﻨﺪ.
ﮐﺎﺭﺍﯾﯽ ﻭ ﻋﻤﻠﮑﺮﺩ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺗﻨﻈﯿــﻢ ﺟﺎﺑﻪﺟﺎﯾﯽ ﮐﻤﭙﺮﺳــﻮﺭ ﻣﻌﻤﻮﻝﺗﺮﯾــﻦ ﺭﻭﺵ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ
ﺑﺎﺭ ﺑﺨﺶ ﭘﯿﻮﺳﺘﻪ ) (1998ARIﺣﺪﻭﺩ 13.5ﺗﺎ Btu/hr.W) 14 0.86ﺗﺎ ( Kw/ton 0.89ﺩﺍﺭﻧﺪ.
)ﺩﺭ ﻣﻮﻗﻌﯿﺖ ﺧﻮﺩ( ﻭ ﺗﻌﺪﺍﺩ ﺷﯿﺮﻫﺎﯼ ﺑﺎﺯ ﺩﺍﺭﺩ. ﺩﻭ ﻧﻮﻉ ﺷﯿﺮ ﻟﻐﺰﻧﺪﻩ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻇﺮﻓﯿﺖ ﮐﻤﭙﺮﺳﻮﺭ ﭘﺮﻭﺍﻧﻪﺍﯼ، ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ .ﺍﻭﻟﯽ ﺩﺭ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﮐﻮﭼﮏﺗﺮ ﺑﺎ ﻣﺠﺎﺭﯼ ﺛﺎﺑﺖ ،ﺑﺎﺯ ﻭ ﺑﺴﺘﻪ ﺷﺪﻩ ﻭ ﺗﺎﺛﯿﺮﯼ ﻣﺸﺎﺑﻪ ﺷﯿﺮﻫﺎﯼ ﺑﺎﻻﺭﻭﻧﺪﻩ ﺩﺍﺭﺩ. ﺩﻭﻣﯽ ﮐﻪ ﻣﻌﻤﻮﻻ ﺩﺭ ﻣﺎﺷــﯿﻦﻫﺎﯼ ﺑﺰﺭﮒ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ ،ﻫﻢ ﺟﺎﺑﻪﺟﺎﯾــﯽ ﻭ ﻫﻢ ﻣﻮﻗﻌﯿﺖ ﻭ ﺍﻧﺪﺍﺯﻩ ﻣﺠــﺮﺍﯼ ﺗﺨﻠﯿﻪ ﺭﺍ ﺩﺭ ﺩﺍﻣﻨﻪ ﻧﻈــﺮﯼ ﺁﻥ ،ﺗﻨﻈﯿﻢ ﻣﯽﮐﻨــﺪ .ﺩﺭ ﻫﺮ ﺩﻭ ﻣﻮﺭﺩ ،ﺑﺎ ﺗﻨﻈﯿﻢ ﺷــﯿﺮ ﻟﻐﺰﻧﺪﻩ ،ﻣﺠﺮﺍﯾﯽ ﺷــﻌﺎﻋﯽ ﭘﺪﯾﺪﺁﻣﺪﻩ ﻭ ﺟﺎﺑﻪﺟﺎﯾﯽ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭ، ﮐﺎﻫﺶ ﻣﯽﯾﺎﺑﺪ. ﺷﯿﺮﻫﺎﯼ ﻟﻐﺰﺷﯽ ،ﺍﻧﺪﮐﯽ ﺑﯿﺶ ﺍﺯ ﺷﯿﺮﻫﺎﯼ ﺑﺎﻻﺭﻭﻧﺪﻩ ،ﮐﺎﺭﺍﯾﯽ ﺩﺍﺭﻧﺪ؛ ﺍﻟﺒﺘﻪ ﮐﻨﺘﺮﻝ ﻇﺮﻓﯿﺖ ﺑﺎ ﻫﺮ ﺩﻭ ﺁﻥﻫﺎ ﺩﺭ ﻣﻮﺍﺭﺩﯼ ﻧﺎﮐﺎﺭﺁﻣﺪ ﺍﺳــﺖ .ﺩﺭﻣﻘﺎﺑﻞ ،ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﻣﺮﺣﻠﻪﺍﯼ ﻭ ﭼﻨﺪﮔﺎﻧﻪ ﺩﺭ ﺳﯿﺴــﺘﻤﯽ ﺑﺪﻭﻥ ﮐﻨﺘﺮﻝ ﻇﺮﻓﯿﺖ ﻭ ﺑﺎ ﻧﺎﮐﺎﺭﺁﻣﺪﯼ ﻧﺴــﺒﯽ ﻋﻤﻞ ﻣﯽﮐﻨﻨﺪ .ﻭﻗﺘﯽ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﻭﺍﺭ ﺷﺮﻭﻉ ﺑﻪ ﮐﺎﺭ ﻣﯽﮐﻨﺪ ،ﻇﺮﻓﯿﺖ ﺳﯿﺴــﺘﻢ ﺗﺎ ﻣﺮﺣﻠﻪﺍﯼ ﺑﺎﻻ ﻣﯽﺭﻭﺩ .ﺑﺎ ﺗﻮﻗﻒ ﮐﻤﭙﺮﺳــﻮﺭ ،ﻇﺮﻓﯿﺖ
ﺩﺭﻣﻘﺎﯾﺴــﻪ ،ﭼﯿﻠﺮﻫﺎﯼ ﻣﺸــﺎﺑﻪ ﺑﺎ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﭘﺮﻭﺍﻧﻪﺍﯼ ﮐﺎﺭﺍﯾــﯽ ﺑﻬﺘﺮﯼ ﺩﺭ ﺑﺎﺭ ﮐﺎﻣﻞ ﺩﺍﺷــﺘﻪ؛ ﻭﻟﯽ ﮐﺎﺭﺍﯾﯽ ﮐﻤﺘﺮﯼ ﺩﺭ ﺑﺎﺭ ﻧﺎﮐﺎﻣﻞ ﺩﺭ ﻣﻘﺎﯾﺴــﻪ ﺑﺎ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺩﺍﺭﻧﺪ .ﺟﺪﻭﻝ )(A ﮐﺎﺭﺍﯾــﯽ ﻣﻌﻤﻮﻝ ﭼﯿﻠﺮﻫﺎﯼ ﻣﺸــﺎﺑﻪ ﺭﺍ ﺑﺎ ﻋﻤﻠﮑــﺮﺩ ﺍﻧﻮﺍﻉ ﻣﺨﺘﻠﻒ
ﺟﺪﻭﻝ ) (Aﻣﻘﺎﯾﺴﻪ ﮐﺎﺭﺍﯾﯽ ﭼﯿﻠﺮﻫﺎﯼ ﻣﻌﻤﻮﻝ ﺑﺎﺭ ﺑﺨﺶ ﭘﻴﻮﺳـﺘﻪ، Btu/hr.W
ﺩﻭﺍﺭ
ﮐﻤﭙﺮﺳﻮﺭ ﺩﺭ ﻫﻤﺎﻥ ﺷﺮﺍﯾﻂ ،ﻣﻘﺎﯾﺴﻪ ﻣﯽﮐﻨﺪ.
ﭘﺮﻭﺍﻧﻪﺩﻭﮔﺎﻧﻪﭼﺮﺧﻨﺪﻩﺍﺳﺘﺎﻧﺪﺍﺭﺩ
ﺑﺨﺸﯽ ﺍﺯ ﺍﺧﺘﻼﻑ ﺩﺭ ﮐﺎﺭﺍﯾﯽ ﺑﻪ ﻃﺒﯿﻌﺖ ﮐﻨﺘﺮﻝ ﺑﺨﺸﯽ ﺍﺯ ﺑﺎﺭ ﺩﺭ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﮐﻮﭼﮏﺗﺮ ﻭ ﭼﻨﺪﮔﺎﻧﻪ ﺩﺭﺑﺮﺍﺑﺮ ﭘﺮﻭﺍﻧﻪﻫﺎﯼ
ﭘﺮﻭﺍﻧﻪ ﺩﻭﮔﺎﻧﻪ ﭼﺮﺧﻨﺪﻩ ﺑﺎ ﻛﺎﺭﺍﻳﻰ ﺑﺎﻻ
ﺑﺰﺭﮒ ﻭ ﺗﮏ ﺑﺎ ﺷﯿﺮﯼ ﻟﻐﺰﺷﯽ ﯾﺎ ﺑﺎﻻﺭﻭﻧﺪﻩ ،ﺑﺮﻣﯽﮔﺮﺩﺩ. ﻇﺮﻓﯿﺖ ﮐﻤﭙﺮﺳﻮﺭ ﭘﺮﻭﺍﻧﻪﺍﯼ ،ﺑﺴﺘﮕﯽ ﺑﻪ ﺟﺎﺑﻪﺟﺎﯾﯽ ﮐﻤﭙﺮﺳﻮﺭ ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺑـﺎﺭ ﻛﺎﻣـﻞ EER، Btu/hr.W
ﻧﻮﻉ ﻛﻤﭙﺮﺳﻮﺭ ﭼﻴﻠﺮ
ﺗﻮﺟﻪ :ﮐﺎﺭﺍﯾﯽ ﻧﺸﺎﻥﺩﺍﺩﻩﺷﺪﻩ ﺑﻪ ﭼﯿﻠﺮﻫﺎﯼ ﺩﺭ ﺩﺳﺘﺮﺱ ﺗﺎ ﺍﮐﺘﺒﺮ 2004ﺗﻌﻠﻖ ﺩﺍﺭﺩ.
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 13ﺷﻤﺎﺭﻩ 30
ﺟﺪﻭﻝ ) (Bﻣﻘﺎﯾﺴﻪ ﻋﻤﻠﮑﺮﺩ ﮐﻤﭙﺮﺳﻮﺭ ﻣﻌﻤﻮﻝ ﺑﺎﺭ ﺑﺨﺶ ﭘﻴﻮﺳـﺘﻪ ،ﻛﻤﭙﺮﺳﻮﺭﭘﺮﻭﺍﻧﻪﺩﻭﮔﺎﻧﻪﺑﺎ ﻛﻤﭙﺮﺳﻮﺭﻫﺎﻳﻰ ﺑﺎ ﺳﻪ ﺩﻭﺍﺭ Btu/hr.W ﺷﻴﺮﻫﺎﻯ ﺑﺎﻻﺭﻭﻧﺪﻩ ،ﺗﻚ
ﺳﻄﺢ ﻛﻨﺘﺮﻝ ﺗﻚ
ﭘﺎﯾﯿﻦﺁﻣﺪﻩ ﻭ ﺟﺮﯾﺎﻥ ﺍﻧﺮﮊﯼ ﮐﻤﭙﺮﺳﻮﺭ ﻣﺘﻮﻗﻒ ﻣﯽﺷﻮﺩ .ﺟﺪﻭﻝ )(B ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﻭ ﺑﺎﺭ ﺭﺍ ﺑﺮﺣﺴــﺐ ﺩﺭﺻﺪ ﺩﺭ ﺳﯿﺴﺘﻢﻫﺎﯼ ﻣﺸﺎﺑﻪ ﻭ ﺳﻪ ﮐﻤﭙﺮﺳﻮﺭ ﻣﺨﺘﻠﻒ ،ﻧﺸﺎﻥ ﻣﯽﺩﻫﺪ .ﺩﺭ ﺣﺎﻟﺖ ﻧﺨﺴﺖ ،ﺍﺯ ﺳﻪ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﺑﺎ ﮐﻨﺘﺮﻝ ﻇﺮﻓﯿﺖ ﻣﺮﺣﻠﻪﺍﯼ ﺍﺳﺘﻔﺎﺩﻩ ﺷﺪﻩ ﺍﺳﺖ.
ﺗﺼﻮﯾﺮ ) (11ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ Aqua Snapﻣﺪﻝ RA 30 ﮐﺮﯾﺮ 9 ،ﺗﺎ 55ﺗﻦ
ﺩﺭ ﺩﻭﻣﯿﻦ ﻭ ﺳﻮﻣﯿﻦ ﺳﯿﺴﺘﻢ ﺍﺯ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﭘﺮﻭﺍﻧﻪﺍﯼ ﺩﻭﺗﺎﯾﯽ ﻭ ﺗﮏ ﺍﺳــﺘﻔﺎﺩﻩ ﺷﺪﻩ ﺍﺳﺖ ،ﮐﻪ ﺩﺭ ﯾﮑﯽ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻇﺮﻓﯿﺖ ﺍﺯ ﺷــﯿﺮﻫﺎﯼ ﺑﺎﻻﺭﻭﻧﺪﻩ ﻭ ﺩﺭ ﺩﯾﮕﺮﯼ ﺍﺯ ﺷﯿﺮﯼ ﻟﻐﺰﻧﺪﻩ ﺍﺳﺘﻔﺎﺩﻩ ﺷﺪﻩ ﺍﺳﺖ .ﻣﺰﯾﺖ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ،ﺁﺷﮑﺎﺭ ﺍﺳﺖ .ﺩﺭ ﺩﻭﺳﻮﻡ ﺑﺎﺭﮔﺬﺍﺭﯼ، ﮐﻤﭙﺮﺳــﻮﺭ ﭘﺮﻭﺍﻧــﻪﺍﯼ 9% ،ﺗﺎ 27%ﺑﯿﺶ ﺍﺯ ﻣﺎﺷــﯿﻦ ﺩﻭﺍﺭ ﺍﻧﺮﮊﯼ
ﮐﺎﺭﺑﺮﺩﻫﺎ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺩﺭ ﺍﺑﻌﺎﺩ ﻣﺨﺘﻠﻔﯽ ﺗﺎ 25ﺗﻦ ﺳﺎﺧﺘﻪ ﺷﺪﻩ ﻭ ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﮔﻮﻧﺎﮔﻮﻥ ﺳﺮﻣﺎﯾﺸــﯽ ﻭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﻧﺪ .ﺩﺭ ﺯﻣﯿﻨﻪ ﺳﺮﻣﺎﯾﺸــﯽ ،ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺑﻪ ﺻﻮﺭﺕ ﻣﻮﻓﻘﯿﺖﺁﻣﯿــﺰﯼ ﺑﺮﺍﯼ ﺧﻨﮏ ﮐﺮﺩﻥ ﺷــﯿﺮ ،ﺣﻤﻞﻭﻧﻘﻞ ﺟﺎﺩﻩﺍﯼ، ﺩﺭﯾﺎﯾــﯽ ﻭ ﻣﻮﺍﺭﺩ ﻣﻌﻤﻮﻝ ﻓﺮﻭﺷــﮕﺎﻫﯽ ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷــﻮﻧﺪ .ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺧﺎﻧﮕﯽ ﻭ ﺗﺠﺎﺭﯼ ﺳــﺒﮏ ،ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺁﻥﻫﺎ ﺩﺭ ﺯﻣﯿﻨﻪ
ﺗﺼﻮﯾﺮ ) (12ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ Aqua Snapﻣﺪﻝ RB 30 ﮐﺮﯾﺮ 58 ،ﺗﺎ 285ﺗﻦ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺑﯿﺶ ﺍﺯ ﺳﯿﺴﺘﻢ ﺩﻭﺍﺭ ﻣﯽﺭﺳﺪ.
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻣﺼﺮﻑ ﮐﺮﺩﻩ ﻭ ﺩﺭ ﯾﮏﺳﻮﻡ ﺑﺎﺭﮔﺬﺍﺭﯼ ،ﻣﯿﺰﺍﻥ ﺁﻥ ﺑﻪ 61%ﺗﺎ 97%
ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ،ﮐﻪ ﯾﮑﯽ ﺍﺯ ﻧﺨﺴــﺘﯿﻦ ﻣــﻮﺍﺭﺩ ﮐﺎﺭﺑﺮﺩ ﺁﻥﻫﺎ ﺑﻮﺩﻩ، ﺑــﻪ ﺳــﺮﻋﺖ ﺩﺭ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﯾﮏﭘﺎﺭﭼﻪ ،ﭘﻤﭗﻫــﺎﯼ ﺣﺮﺍﺭﺗﯽ، ﺗﻠﻔﻦ55401278 :
ﭼﯿﻠﺮﻫﺎﯼ ﺁﺑﯽ ﺑﺮﺍﯼ ﺧﻨﮏ ﮐﺮﺩﻥ ﺳﺎﺧﺘﻤﺎﻥ ﻭ ﻓﺮﺁﯾﻨﺪ ﻭ ﻭﺍﺣﺪﻫﺎﯼ ﺑﺰﺭﮒ ﺗﻘﻄﯿﺮ ،ﺍﺳﺘﻔﺎﺩﻩ ﺷــﺪﻩﺍﻧﺪ .ﺻﻨﻌﺖ ﺣﻤﻞﻭﻧﻘﻞ ﻧﯿﺰ ﺑﻪ ﺍﯾﻦ ﭘﯿﺸــﺮﻓﺖ ﭘﯿﻮﺳــﺘﻪ ﻭ ﺑﻪ ﻃﻮﺭ ﻣﻮﺛﺮ ﻭ ﻣﻄﻤﺌﻦ ﺍﺯ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺑﺮﺍﯼ ﺗﻬﻮﯾﻪ ﻫﻮﺍﯼ ﺧﻮﺩﺭﻭﻫﺎ ،ﺑﻬﺮﻩ ﮔﺮﻓﺘﻪ ﺍﺳــﺖ .ﻫﻤﭽﻨﯿﻦ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﻣﻌﻤﻮﻻ ﺑﺮﺍﯼ ﺗﺎﻣﯿﻦ ﻫﻮﺍﯼ ﻣﺘﺮﺍﮐﻢﺷــﺪﻩ ﻭ ﺑﺪﻭﻥ ﺭﻭﻏﻦ ،ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ. ﭼﯿﻠﺮﻫﺎﯼ ﺁﺑﯽ ﺍﺯ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ،ﺑﻪ ﻃﻮﺭ ﺳــﻨﺘﯽ ﻭ ﺩﺭ ﻭﺍﺣﺪﻫﺎﯼ ﮐﻮﭼــﮏ ﮐﻤﺘﺮ ﺍﺯ 125ﺗﻦ ﺑﻬــﺮﻩ ﺑﺮﺩﻩﺍﻧﺪ .ﮐﺮﯾﺮ ﭼﯿﻠﺮ ﻫﻮﺍﯾــﯽ Aqua Snapﻣﺪﻝ RA 30ﺭﺍ ﺩﺭ ﺳــﺎﻝ 2001ﻣﻌﺮﻓﯽ ﮐﺮﺩﻩ ﻭ ﻭﺍﺣﺪﻫﺎﯾﯽ ﺗﺎ ﺍﺑﻌﺎﺩ 55ﺗﻦ ﺗﻮﻟﯿﺪ ﻣﯽﮐﻨﺪ )ﺗﺼﻮﯾﺮ .(11 ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﺼﻮﯾﺮ ) (13ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﻟﻮﻟﻪﮐﺸﯽﺷﺪﻩ ﺑﻪ ﯾﮑﺪﯾﮕﺮ ،ﺑﺮ ﯾﮏ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸﯽ ﻣﻌﻤﻮﻝ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻣﻮﻓﻘﯿــﺖ ﺑﺰﺭﮔﯽ ﺑﻪ ﺷــﻤﺎﺭ ﻣﯽﺁﯾﺪ .ﺩﺭ ﻣﻮﺍﺭﺩ ﺗﺠﺎﺭﯼ ﮔﺴــﺘﺮﺩﻩ،
ﺻﻔﺤﻪ / 14ﺷﻤﺎﺭﻩ 30
ﻣﻌﺮﻓــﯽ ﭼﯿﻠﺮ Aqua Snapﻣﺪﻝ ،RB 30ﺗﺼﻮﯾﺮ ) (12ﺑﻪ
ﻣﯿﻠﯿﻮﻥﻫﺎ ﮐﻤﭙﺮﺳﻮﺭ ﺩﻭﺍﺭ ﺑﻪ ﻃﻮﺭ ﻣﻮﻓﻘﯿﺖﺁﻣﯿﺰﯼ ﺩﺭ ﺳﺮﺍﺳﺮ ﺩﻧﯿﺎ
ﻭﺳــﯿﻠﻪ ﮐﺮﯾﺮ ،ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ ﺭﺍ ﺑــﻪ ﻇﺮﻓﯿﺘﯽ ﺑﯿﻦ 58ﺗﺎ 285
ﺩﺭ ﺳــﺮﻣﺎﯾﺶ ﻓﺮﻭﺷــﮕﺎﻩﻫﺎ ﻭ ﻣﻮﺍﺩ ﻏﺬﺍﯾﯽ ،ﺣﻤﻞﻭﻧﻘﻞ ﺟﺎﺩﻩﺍﯼ،
ﺗﻦ ﺭﺳــﺎﻧﺪﻩ ﺍﺳــﺖ .ﮐﻮﭼﮏﺗﺮﯾﻦ ﺍﻧﺪﺍﺯﻩ ،ﺳــﻪ ﮐﻤﭙﺮﺳﻮﺭ 20ﺗﻦ
ﺩﺭﯾﺎﯾﯽ ﻭ ﺗﻬﻮﯾﻪ ﻫﻮﺍﯼ ﺳــﺒﮏ ﺗﺠــﺎﺭﯼ ﻭ ﺧﺎﻧﮕﯽ ،ﻧﻘﺶ ﺧﻮﺩ ﺭﺍ
ﺗﮏ ﺑﺮ ﺩﻭ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸــﯽ ﺩﺍﺭﺩ )ﯾــﮏ ﻣﺪﺍﺭ 20ﺗﻦ ﻭ ﯾﮏ ﻣﺪﺍﺭ
ﺍﯾﻔﺎ ﮐﺮﺩﻩﺍﻧﺪ.
40ﺗﻦ( .ﺍﺯ ﻃﺮﻑ ﻣﻘﺎﺑﻞ ،ﭼﯿﻠﺮ 285ﺗﻦ 12 ،ﮐﻤﭙﺮﺳــﻮﺭ 25ﺗﻦ ﺩﻭﺍﺯﺩﻩﺗﺎﯾﯽ ﺑﺮ ﺳــﻪ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﺮﺍﺑﺮ ﺩﺍﺭﺩ .ﺗﻤﺎﻡ ﺍﺑﻌﺎﺩ ﻣﺪﻝ RB 30ﺑﺎ ﺣﺪﺍﻗﻞ ﺩﻭ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸــﯽ ﻣﺴﺘﻘﻞ ﺑﻮﺩﻩ ﻭ ﺣﺪﺍﮐﺜﺮ ﺗﻌﺪﺍﺩ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎ ﺑﻪﺍﺯﺍﯼ ﻫﺮ ﻣﺪﺍﺭ ،ﭼﻬﺎﺭ ﺍﺳﺖ .ﺍﺑﻌﺎﺩ ﻣﺴﺘﻘﻞ ﮐﻤﭙﺮﺳﻮﺭ ﺩﺭ ﻣﺪﺍﺭ ﺩﺍﺩﻩﺷﺪﻩ ﻣﻤﮑﻦ ﺍﺳﺖ ﺗﺮﮐﯿﺒﯽ ﻭ ﻣﺸﺎﺑﻪ ﺗﺼﻮﯾﺮ ) (13ﺑﺎﺷــﺪ )ﺑﻪ ﻃــﻮﺭ ﻣﺜﺎﻝ 10 ،ﺗﻦ ﺑﺎ ﮐﻤﭙﺮﺳــﻮﺭﯼ 5/12ﺗﻦ ﺟﻔﺖ ﻣﯽﺷﻮﺩ(.
ﺭﺳﺎﻧﺪﻩ ﺍﺳﺖ .ﺗﺤﻘﯿﻖ ﻭ ﺗﻮﺳــﻌﻪ ﭘﯿﻮﺳﺘﻪ ﻓﻦﺁﻭﺭﯼ ﺩﻭﺍﺭ ،ﺍﻣﮑﺎﻥ ﺳﺎﺧﺖ ﻭﺍﺣﺪﻫﺎﯾﯽ ﺗﮏ ﺗﺎ ﺑﯿﺴﺖﻭﭘﻨﺞ ﺗﻦ ﺭﺍ ﻓﺮﺍﻫﻢ ﻧﻤﻮﺩﻩ ﺍﺳﺖ. ﻭﺍﺣﺪﻫﺎﯼ ﮐﻤﭙﺮﺳــﻮﺭ ﺑﺎ ﺩﻭ ،ﺳــﻪ ﻭ ﭼﻬﺎﺭ ﮐﻤﭙﺮﺳــﻮﺭ ،ﺍﺳﺘﻔﺎﺩﻩ ﻣﻮﻓﻘﯿﺖﺁﻣﯿﺰ ﺍﺯ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺭﺍ ﺩﺭ ﭼﯿﻠﺮﻫﺎﯾﯽ ﺑﺎ ﻇﺮﻓﯿﺖ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺩﺭ ﮐﺎﺭﺑﺮﺩ ،ﮐﯿﻔﯿﺖﻫﺎﯼ ﻣﺘﻤﺎﯾﺰﯼ ﺩﺍﺭﻧﺪ.
ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺗﻬﻮﯾــﻪ ﻣﻄﺒﻮﻉ ،ﻣﻮﻓﻖ
ﺁﻥﻫﺎ ﮐﺎﺭﺍ ،ﺁﺭﺍﻡ ﻭ ﻣﻄﻤﺌﻦ ﻫﺴــﺘﻨﺪ؛ ﺍﻟﺒﺘﻪ ﺗــﺎ ﺯﻣﺎﻧﯽ ﮐﻪ ﺑﺎ ﯾﮏ
ﻋﻤﻞ ﮐﺮﺩﻩﺍﻧﺪ .ﻣﻮﻓﻘﯿﺖ ﺳﺮﯾﻊ ﺁﻥﻫﺎ ﺗﻘﺎﺿﺎﯼ ﻣﯿﻠﯿﻮﻥﻫﺎ ﺍﺯ ﺁﻥﻫﺎ
ﻓﻦﺁﻭﺭﯼ ﺭﻗﯿﺐ ﻣﻘﺎﯾﺴــﻪ ﻧﺸــﻮﻧﺪ ،ﻧﻤﯽﺗﻮﺍﻥ ﺑــﻪ ﻣﺰﺍﯾﺎ ﻭ ﻣﻌﺎﯾﺐ
ﺭﺍ ﺩﺭ ﺑﯿﺴﺖ ﺳــﺎﻝ ﮔﺬﺷﺘﻪ ،ﭘﺪﯾﺪ ﺁﻭﺭﺩﻩ ﺍﺳــﺖ .ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ
ﺁﻥﻫــﺎ ﭘﯽ ﺑﺮﺩ .ﺑﻪ ﻫﻤﯿــﻦ ﺩﻟﯿﻞ ،ﺟــﺪﻭﻝ ) ،(Cﻣﺰﺍﯾﺎ ﻭ ﻣﻌﺎﯾﺐ
ﺩﻭﺍﺭ ،ﻗﺎﺑﻠﯿﺖ ﺧﻮﺩ ﺭﺍ ﺍﺛﺒﺎﺕ ﮐﺮﺩﻩ ﻭ ﻧﺸــﺎﻥ ﺩﺍﺩﻩﺍﻧﺪ ﮐﻪ ﺑﻪ ﺧﻮﺑﯽ
ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺭﺍ ﺩﺭ ﻣﻘﺎﯾﺴــﻪ ﺑﺎ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﭘﺮﻭﺍﻧﻪﺍﯼ
ﺩﯾﮕــﺮ ﻓﻦﺁﻭﺭﯼﻫﺎ ﺑﻮﺩﻩ ﻭ ﺣﺘــﺎ ﺑﺮﺗﺮﻧﺪ .ﺍﺯ ﺯﻣــﺎﻥ ﻣﻌﺮﻓﯽ ﺁﻥﻫﺎ،
ﺩﻭﮔﺎﻧﻪ ﭼﺮﺧﻨﺪﻩ ،ﻧﺸﺎﻥ ﻣﯽﺩﻫﺪ.
ﺟﺪﻭﻝ ) (Cﻣﻘﺎﯾﺴﻪ ﻣﺰﺍﯾﺎ ﻭ ﻣﻌﺎﯾﺐ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯾﯽ ﺑﺎ ﭘﺮﻭﺍﻧﻪ ﺩﻭﮔﺎﻧﻪ ،ﭼﺮﺧﻨﺪﻩ
ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ
○ ﻛﺎﺭﺍﻳﻰ ﺧﻮﺏ ﺩﺭ ﺑﺎﺭﻛﺎﻣﻞ ﻭ ﺑﺨﺸﻰ ﺍﺯ ﺑﺎﺭ ○ ﻗﻄﻌﺎﺕ ﻣﺘﺤﺮﻙ ﺑﺴــﻴﺎﺭ ﺍﻧﺪﻙ )ﺳﻪ ﻗﻄﻌﻪ ﻳﺎ ﺑﻴﺸﺘﺮ ،ﺑﺴﺘﻪ ﺑﻪ ﺭﻭﺵ ﻛﻨﺘﺮﻝ ﻇﺮﻓﻴﺖ( ○ ﻗﺎﺑﻠﻴﺖ ﺍﺛﺒﺎﺕﺷﺪﻩ ○ ﭘﻴﻮﺳﺘﮕﻰ ﺭﻭﻧﺪ ﺗﺮﺍﻛﻢ ﺗﻘﺮﻳﺒﺎ ﺑﺪﻭﻥ ﺿﺮﺑﻪ ﻳﺎ ﻟﺮﺯﺵ ○ ﻛﻨﺘﺮﻝ ﻇﺮﻓﻴﺖ ﺑﻴﻦ ﺑﺎﺭﮔﺬﺍﺭﻯ ﺣﺪﺍﻗﻞ ﻭ ﺣﺪﺍﻛﺜﺮ ○ ﻟﺮﺯﺵ ﻛﻢ
○ ﻛﺎﺭﺍﻳﻰ ﺧﻮﺏ ﺩﺭ ﺑﺎﺭﻛﺎﻣﻞ ﻭ ﺑﺨﺸﻰ ﺍﺯ ﺑﺎﺭ ○ ﭼﻴﻠﺮﻫــﺎ ﺑﺎ ﭼﻨﺪ ﻛﻤﭙﺮﺳــﻮﺭ ﺑﺮ ﻣﺪﺍﺭﻫﺎﻯ ﻣﻌﻤﻮﻝ ﺳﺮﻣﺎﻳﺸــﻰ ﻋﻤﻞ ﻛﺮﺩﻩ ﻭ ﻛﺎﺭﺍﻳﻰ ﺑﻬﺘﺮﻯ ﺩﺭ ﺑﺨﺸــﻰ ﺍﺯ ﺑﺎﺭ ،ﻧﺴﺒﺖ ﺑﻪ ﻛﻤﭙﺮﺳﻮﺭ ﭘﺮﻭﺍﻧﻪﺍﻯ ﺑﺰﺭگ ﻭ ﺗﻚ ﺩﺍﺷﺘﻪ ﻭ ﻛﻨﺘﺮﻝ ﻇﺮﻓﻴﺖ ﺑﻬﺘﺮﻯ ﺩﺍﺭﻧﺪ. ○ ﻗﻄﻌﺎﺕ ﻣﺘﺤﺮﻙ ﺑﺴﻴﺎﺭ ﺍﻧﺪﻙ )ﺳﻪ ﻗﻄﻌﻪ( ○ ﻗﺎﺑﻠﻴﺖ ﺍﺛﺒﺎﺕﺷﺪﻩ ○ ﺍﺯ ﺩﺳــﺖ ﺭﻓﺘﻦ ﻳﻚ ﻛﻤﭙﺮﺳــﻮﺭ ﺩﺭ ﭼﻴﻠﺮﻯ ﺑﺎ ﭼﻨﺪ ﻣﺪﺍﺭ ﺳﺮﻣﺎﻳﺸﻰ ﺑﺎﻋﺚ ﻛﺎﻫﺶ ﻇﺮﻓﻴﺖ ﻣﻰﺷﻮﺩ؛ ﻭﻟﻰ ﭼﻴﻠﺮ ﺑﻪ ﻛﺎﺭ ﺧﻮﺩ ﺍﺩﺍﻣﻪ ﻣﻰﺩﻫﺪ. ○ ﻋﻤﻠﻜﺮﺩﻯ ﺑﺴﻴﺎﺭ ﺁﺭﺍﻡ ○ ﻟﺮﺯﺵ ﻛﻢ ○ ﭘﻴﻮﺳﺘﮕﻰ ﺭﻭﻧﺪ ﺗﺮﺍﻛﻢ ﺗﻘﺮﻳﺒﺎ ﺑﺪﻭﻥ ﺿﺮﺑﻪ ﻳﺎ ﻟﺮﺯﺵ ○ ﺍﻣﻜﺎﻥ ﺁﺏﺑﻨﺪﻯ ﺩﻗﻴﻖ ﭘﺮﻩﻫﺎ ﺑﺎ ﻻﻳﻪ ﻧﺎﺯﻛﻰ ﺍﺯ ﺭﻭﻏﻦ ○ ﻃﺮﺡﻫــﺎﻯ ﺑﺪﻭﻥ ﺗﻄﺒﻴﻖ )ﻛﻪ ﺩﺭ ﺁﻥﻫﺎ ﺗﻤﺎﺳــﻰ ﺑﻴﻦ ﺩﻭﺍﺭﻫﺎ ﻭﺟﻮﺩ ﻧﺪﺍﺭﺩ( ﺍﺻﻄﻜﺎﻙ ﺑﺴﻴﺎﺭ ﻛﻤﻰ ﺩﺍﺷﺘﻪ ﻭ ﻛﺎﺭﺍﻳﻰ ﺑﻬﺘﺮﻯ ﺩﺍﺭﻧﺪ.
○ ﺳﺮﻭﺻﺪﺍﻯ ﺑﻴﺸﺘﺮ ﻧﺴﺒﺖ ﺑﻪ ﻛﻤﭙﺮﺳﻮﺭﻫﺎﻯ ﺩﻭﺍﺭ ○ ﻧﻴﺎﺯﻣﻨﺪ ﺟﺮﻳﺎﻥ ﺭﻭﻏﻦ ﺑﺮﺍﻯ ﺁﺏﺑﻨﺪﻯ ﻗﺴﻤﺖﻫﺎﻯ ﻛﻤﭙﺮﺳﻮﺭ ○ ﻧﻴﺎﺯ ﺑﻪ ﺧﻔﻪﻛﻦ ﺧﺮﻭﺟﻰ ﻭ ﺟﺪﺍﻛﻨﻨﺪﻩ ﺭﻭﻏﻦ ○ ﺍﺯ ﺩﺳــﺖ ﺭﻓﺘﻦ ﻳﻚ ﻛﻤﭙﺮﺳــﻮﺭ ﺩﺭ ﭼﻴﻠﺮﻯ ﺗﻨﻬﺎ ﺑﺎ ﻳﻚ ﻛﻤﭙﺮﺳــﻮﺭ ﺑﺎﻋﺚ ﺍﺯ ﺩﺳﺖ ﺭﻓﺘﻦ ﻛﺎﻣﻞ ﺳﺮﻣﺎﻳﺶ ﻣﻰﺷﻮﺩ.
○ ﻛﻤﭙﺮﺳﻮﺭ ﺭﺍ ﻧﻤﻰﺗﻮﺍﻥ ﺑﺮﺍﻯ ﺗﻌﻤﻴﺮ ،ﺩﺭ ﻣﺤﻴﻂ ﺑﺎﺯ ﻛﺮﺩ. ○ ﻛﻨﺘﺮﻝ ﻇﺮﻓﻴﺖ ﺍﺿﺎﻓﻰ ﺑﺮ ﺳﻴﺴﺘﻢ ﻫﺎﻳﻰ ﺑﺎ ﭼﻨﺪ ﻛﻤﭙﺮﺳﻮﺭ
ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﮐﺮﯾﺮ ،ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﺩﻭﺍﺭ ﺭﺍ ﺑﻪ ﻧﻘﻄﻪ ﻣﻬﻤﯽ ﺩﺭ ﺗﺎﺭﯾﺦ ﺧﻮﺩ
ﮐﻞ ﺗﻘﺮﯾﺒﯽ 300ﺗﻦ ،ﺍﻣﮑﺎﻥﭘﺬﯾﺮ ﮐﺮﺩﻩ ﺍﺳﺖ.
ﻣﯿﺰﺍﻥ ﺍﻃﻤﯿﻨﺎﻥ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺟﻤﻊﺑﻨﺪﯼ
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻣﺰﺍﯾﺎ
ﻣﻌﺎﯾﺐ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 15ﺷﻤﺎﺭﻩ 30
ﻛﺎﺭﺑﺮﺩﻯ
ﺻﺪﺍ ﺩﺭ ﺗﺠﻬﻴﺰﺍﺕ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﺑﺮﺍﯼ ﺁﻥﮐﻪ ﺻﺪﺍ ﺭﺍ ﺩﺭ ﻣﺤﺼﻮﻻﺕ ﮐﺮﯾﺮ ﺗﺒﺪﯾﻞ ﺑﻪ ﻣﻬﻢﺗﺮﯾﻦ ﻣﺰﯾﺖ ﮐﻨﯿﻢ ،ﺗﻤﺎﻡ ﺗﻮﺯﯾﻊﮐﻨﻨﺪﮔﺎﻥ ﻭ ﻓﺮﻭﺷــﻨﺪﮔﺎﻥ ﺑﺎﯾﺪ ﭼﮕﻮﻧﮕﯽ ﺗﻮﻟﯿﺪ، ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﻭ ﻣﻘﺎﯾﺴــﻪ ﺍﺻﻮﺍﺕ ﺭﺍ ﻓﺮﺍﮔﯿﺮﻧﺪ .ﺍﯾﻦ ﺍﻣﺮ ﺷﻤﺎ ﺭﺍ ﻗﺎﺩﺭ ﺑﻪ
ﻧﻘﺶ ﺻﺪﺍ ﺩﺭ ﺭﺿﺎﯾﺖ ﻣﺸﺘﺮﯼ ﺻﺪﺍ ﻧﻘﺶ ﻣﻬﻤﯽ ﺩﺭ ﺯﻧﺪﮔﯽ ﺭﻭﺯﻣﺮﻩ ﻣﺮﺩﻡ ﺍﯾﻔﺎ ﻣﯽﮐﻨﺪ .ﺍﺯ ﻭﻗﺘﯽ ﺑﺎ ﺯﻧﮓ ﺍﻟﮑﺘﺮﻭﻧﯿﮏ ﺳــﺎﻋﺖ ،ﺑﯿﺪﺍﺭ ﻣﯽﺷﻮﯾﻢ ﺗﺎ ﻭﻗﺘﯽ ﺩﺭ ﭘﺎﯾﺎﻥ ﺭﻭﺯ ﺑﻪ ﺟﺎﯾﯽ ﺁﺭﺍﻡ ﺑﺮﺍﯼ ﺍﺳــﺘﺮﺍﺣﺖ ﺑﺎﺯﻣﯽﮔﺮﺩﯾﻢ ،ﺩﺭ ﺧﺎﻧﻪ ،ﻣﺤﻞ ﮐﺎﺭ ﻭ ﺗﻔﺮﯾﺢ ،ﺗﺤﺖ ﻓﺸﺎﺭ ﺑﯽﺍﻣﺎﻥ ﺧﻮﺷﺎﯾﻨﺪ ﯾﺎ ﻧﺎﺧﻮﺷﺎﯾﻨﺪ ﺍﺻﻮﺍﺕ ﻫﺴﺘﯿﻢ. ﺩﺭ ﺗــﻼﺵ ﺑﺮﺍﯼ ﺭﺍﻧــﺪﻥ ﺻﺪﺍ ﺍﺯ ﺯﻧﺪﮔﯽ ﺧــﻮﺩ ،ﺭﻭﺯﺑﻪﺭﻭﺯ ﻣﺎﻟﮑﺎﻥ ﺑﺮ ﮐﺎﻫﺶ ﺍﺻﻮﺍﺕ ﻧﺎﺧﻮﺍﺳﺘﻪ ﺩﺭ ﻣﺤﯿﻂ ﺯﻧﺪﮔﯽ ﺧﻮﺩ ،ﻣﺘﻤﺮﮐﺰ ﻣﯽﺷﻮﻧﺪ. ﺩﺭ ﺍﯾﻦ ﺑﯿﻦ ،ﺑﺮﺍﯼ ﻣﺎﻟﮑﯽ ﻣﻌﻤﻮﻟﯽ ،ﺗﺠﻬﯿﺰﺍﺕ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ،ﺟﺰﻭ ﺍﻗﻼﻣﯽ ﻫﺴﺘﻨﺪ ﮐﻪ ﺗﺮﺟﯿﺢ ﻣﯽﺩﻫﻨﺪ ﺁﺭﺍﻡ ﻭ ﺑﯽﺻﺪﺍ ﺑﺎﺷﻨﺪ. ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺗﻠﻔﻦ55401278 :
ﻣﺎﻟﮑﺎﻥ ﺍﺯ ﻣﺘﻔﺎﻭﺕ ﺑﻮﺩﻥ ﻣﺤﺼﻮﻻﺕ ﮐﺮﯾﺮ ﻣﯽﮐﻨﺪ.
ﻣﻘﺎﺩﯾﺮ ﺻﻮﺗﯽ ARIﺑﻪ ﻭﺳﯿﻠﻪ ﮐﺮﯾﺮ ﻭ ﺑﺮﺧﯽ ﺩﯾﮕﺮ ﺍﺯ ﺳﺎﺯﻧﺪﮔﺎﻥ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ،ﭘﺪﯾﺪ ﺁﻣﺪﻩ ﻭ ﺳﯿﺴــﺘﻢ ﺍﺳﺘﺎﻧﺪﺍﺭﺩﯼ ﺍﺧﺘﯿﺎﺭﯼ ﺍﺳﺖ ﮐﻪ ﺑﻪ ﻣﺸﺘﺮﯾﺎﻥ ﺍﻣﮑﺎﻥ ﻣﻘﺎﯾﺴﻪ ﺩﻗﯿﻘﯽ ﺑﯿﻦ ﻣﺤﺼﻮﻻﺕ ﺭﺍ ﻣﯽﺩﻫﺪ. ﺍﯾﻦ ﻣﺎﻧﻨﺪ ﻣﻘﺎﯾﺴــﻪ ﻣﺎﯾﻞ ﺑﻪﺍﺯﺍﯼ ﻫﺮ ﮔﺎﻟﻮﻥ ﺩﺭ ﯾﮏ ﺧﻮﺩﺭﻭﯼ ﺟﺪﯾﺪ ﺍﺳﺖ. ﺍﻏﻠﺐ ﻣﺸــﺘﺮﯾﺎﻥ ﺑﺎ ﻭﺍﮊﻩ "ﻣﺎﯾﻞ ﺑﻪﺍﺯﺍﯼ ﻫﺮ ﮔﺎﻟﻮﻥ" ﺁﺷــﻨﺎ ﺑﻮﺩﻩ ﻭ ﻣﯽﺩﺍﻧﻨﺪ ﮐﻪ ﻋﺎﺩﺕﻫــﺎﯼ ﺭﺍﻧﻨﺪﮔﯽ ،ﻋﻮﺍﺭﺽ ﺯﻣﯿــﻦ ،ﺭﺍﻧﻨﺪﮔﯽ ﺩﺭ ﺷــﻬﺮ ﯾﺎ ﺑﺰﺭﮔﺮﺍﻩ ،ﻧﻮﻉ ﺳﻮﺧﺖ ﻣﺼﺮﻓﯽ ﻭ ﻣﺘﻐﯿﺮﻫﺎﯼ ﺩﯾﮕﺮ ﺑﺮ ﻣﻘﺪﺍﺭ ﻋﻤﻠــﯽ ﺁﻥ ﺍﺛﺮ ﻣﯽﮔﺬﺍﺭﻧﺪ .ﺩﺭﻋﯿﻦ ﺣﺎﻝ ،ﺁﻥﻫﺎ ﻣﻔﻬﻮﻡ "ﻣﺎﯾﻞ ﺑﻪﺍﺯﺍﯼ ﻫﺮ ﮔﺎﻟﻮﻥ" ﺭﺍ ﺑﻪ ﻋﻨﻮﺍﻥ ﯾﮏ ﺭﺍﻩ ﺧﻮﺏ ﺑﺮﺍﯼ ﻣﻘﺎﯾﺴــﻪ ﺍﻧﻮﺍﻉ ﻣﺨﺘﻠﻒ ﺧﻮﺩﺭﻭ ﻭ ﺗﻔﺎﻭﺕﻫﺎﯼ ﺑﯿﻦ ﺁﻥﻫﺎ ،ﻣﯽﭘﺬﯾﺮﻧﺪ. ﻣﺎﻟﮑﺎﻧﯽ ﮐﻪ ﻗﺼﺪ ﺧﺮﯾﺪ ﺗﺠﻬﯿﺰﺍﺕ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺭﺍ ﺩﺍﺭﻧﺪ ،ﺑﺎﯾﺪ ﺑﺪﺍﻧﻨﺪ ﮐﻪ ﻣﻘﺎﺩﯾﺮ ﺻﻮﺗﯽ ARIﮐﺮﯾﺮ ،ﻣﯿﺰﺍﻥ ﺧﻮﺑﯽ ﺑﺮﺍﯼ ﻣﻘﺎﯾﺴﻪ ﺭﻗﺒﺎ ﺑﻮﺩﻩ ﻭ ﻓﻬﺮﺳﺘﯽ ﺍﺯ ﻣﻘﺎﺩﯾﺮ ﺻﻮﺗﯽ ﻣﺤﺼﻮﻻﺕ ﺁﻥﻫﺎ ﺑﻪ ﺩﺳﺖ ﻣﯽﺩﻫﺪ. ﺩﺭ ﻋﯿﻦ ﺣﺎﻝ ،ﺍﯾﺸﺎﻥ ﺑﺎﯾﺪ ﺩﺭﻧﻈﺮ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻨﺪ ﮐﻪ ﺷﺮﺍﯾﻂ ﻣﺤﯿﻄﯽ، ﻣﺤــﻞ ﻧﺼﺐ ﻭ ﺩﯾﮕﺮ ﻣﺘﻐﯿﺮﻫﺎ ﻧﯿﺰ ﺑﺮ ﻣﻘﺪﺍﺭ ﺻﺪﺍﯼ ﻣﻨﺘﺸﺮﺷــﺪﻩ ﺍﺯ
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﮔﻔﺖﻭﮔﻮﯾﯽ ﺑﻬﺘﺮ ﺩﺭ ﺯﻣﯿﻨــﻪ ﺗﻔﺎﻭﺕﻫﺎﯼ ﺻﻮﺗﯽ ﻭ ﭼﮕﻮﻧﮕﯽ ﺍﻧﺘﻈﺎﺭ
ﻣﻘﺎﺩﯾﺮ ﺻﻮﺗﯽ ARIﻭ ﻣﺎﯾﻞ ﺑﻪﺍﺯﺍﯼ ﻫﺮ ﮔﺎﻟﻮﻥ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻭﻗﺘﯽ ﻣﺸــﺘﺮﯾﺎﻥ ﺑــﻪ ﻣﺘﺨﺼﺼــﺎﻥ ﮐﺮﯾﺮ ﻣﺮﺍﺟﻌــﻪ ﻣﯽﮐﻨﻨﺪ، ﺁﻥﻫــﺎ ﺍﻧﺘﻈﺎﺭ ﺑﻬﺘﺮﯾﻦﻫﺎ ﺭﺍ ﺩﺭ ﺯﻣﯿﻨﻪ ﻧــﻮﺁﻭﺭﯼ ،ﻓﻦﺁﻭﺭﯼ ،ﮐﯿﻔﯿﺖ ﻭ ﺧﺪﻣﺎﺕﺭﺳــﺎﻧﯽ ﺩﺭ ﺗﻬﻮﯾــﻪ ﻣﻄﺒــﻮﻉ ﺩﺍﺭﻧﺪ. ﺑﻪ ﻃﻮﺭ ﺭﻭﺯﺍﻓﺰﻭﻧﯽ ،ﻭﻗﺘﯽ ﻣﺮﺩﻡ ﺩﺭﺑﺎﺭﻩ ﮐﯿﻔﯿﺖ ﺑﺎﻻﯼ ﻣﺤﺼﻮﻻﺕ ﻣﯽﺍﻧﺪﯾﺸﻨﺪ ،ﺻﺪﺍ ﺭﺍ ﻋﺎﻣﻠﯽ ﮐﻠﯿــﺪﯼ ﺩﺭ ﺗﺼﻤﯿﻢﮔﯿــﺮﯼ ﺧﻮﺩ ﺑﻪ ﺷــﻤﺎﺭ ﻣﯽﺁﻭﺭﻧﺪ. ﺑﻪﻣﻨﻈﻮﺭ ﺣﻔﻆ ﺣﺎﺷــﯿﻪ ﺭﻗﺎﺑﺘــﯽ ،ﺑﺎﯾﺪ ﭘﯿﻮﺳﺘﻪ ﺑﻪ ﺟﺴﺖﻭﺟﻮﯼ ﺭﺍﻩﻫﺎﯾﯽ ﺑﺮﺍﯼ ﮐﺎﻫﺶ ﺻﺪﺍ ﺑﺎ ﺗﻮﺳــﻌﻪ ﻣﺤﺼﻮﻻﺕ ﺟﺪﯾــﺪ ﻭ ﺑﻬﺒﻮﺩ ﺧﻄﻮﻁ ﺗﻮﻟﯿﺪ ﺑﺎﺷﯿﻢ .ﺍﺣﺴﺎﺱ ﻣﯽﮐﻨﯿﻢ ﮐﻪ ﺑﺎ ﺣﺬﻑ ﺻﺪﺍ ﺍﺯ ﻣﺤﺼﻮﻝ ،ﺑﻪ ﺗﻮﺯﯾﻊﮐﻨﻨﺪﮔﺎﻥ ﻭ ﻓﺮﻭﺷﻨﺪﮔﺎﻥ ﺧﻮﺩ ﻣﺰﯾﺘﯽ ﺩﺭ ﻓﺮﻭﺵ ﻣﺤﺼﻮﻻﺕ ﮐﺮﯾﺮ ،ﺑﺨﺸﯿﺪﻩﺍﯾﻢ.
ﮐﯿﻔﯿﺖ ﭘﯿﭽﯿﺪﻩ ﺻﺪﺍ ﻭ ﭼﮕﻮﻧﮕﯽ ﺭﺳﯿﺪﻥ ﺁﻥﻫﺎ ﺑﻪ ﮔﻮﺵ ﺁﺩﻣﯽ، ﺁﻥﻫﺎ ﺭﺍ ﺑﻠﻨﺪﺗــﺮ ،ﺁﺭﺍﻡﺗﺮ ،ﺁﺯﺍﺭﺩﻫﻨﺪﻩ ﻭ ﺁﺭﺍﻡﺑﺨﺶ ﻣﯽﮐﻨﺪ .ﺍﯾﻦ ﺗﻨﻮﻉ ﺑﺎﻋﺚ ﻣﯽﺷﻮﺩ ﺗﺎ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﺩﻗﯿﻖ ﻭ ﻣﻘﺎﯾﺴﻪ ﺍﺻﻮﺍﺕ ،ﺳــﺨﺖ ﺷــﻮﺩ .ﻭﻗﺘﯽ ﺑﻪ ﻣﻘﺎﯾﺴــﻪ ﺳــﻄﻮﺡ ﺻﻮﺗﯽ ﻣﺤﺼﻮﻻﺗــﯽ ﻣﯽﭘﺮﺩﺍﺯﯾﻢ ﮐﻪ ﻧﻤﯽﺗﻮﺍﻥ ﺁﻥﻫﺎ ﺭﺍ ﺑﻪ ﺻﻮﺭﺕ ﺟﺰﺑﻪﺟﺰ ﺑﺮﺭﺳــﯽ ﮐﺮﺩ ،ﻧﯿﺎﺯ ﺑﻪ ﺳﯿﺴﺘﻢ ﭘﺎﯾﺪﺍﺭﯼ ﺑﺮﺍﯼ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ، ﺧﻮﺍﻫﯿﻢ ﺩﺍﺷﺖ .ﺑﻪ ﻫﻤﯿﻦ ﺩﻟﯿﻞ ،ﻓﻬﻢ ﺻﺪﺍﯼ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﻭ ﭼﮕﻮﻧﮕﯽ ﺗﻔﺴﯿﺮ ﺁﻥﻫــﺎ ﺑﺮﺍﯼ ﻣﺸــﺘﺮﯾﺎﻥ ،ﺍﻫﻤﯿﺖ ﺯﯾــﺎﺩﯼ ﺩﺭ ﻓﺮﻭﺵ ﺳﯿﺴــﺘﻢﻫﺎ ﻭ ﺟﻠﺐ ﺭﺿﺎﯾﺖ ﻣﺸﺘﺮﯾﺎﻥ ﺧﻮﺍﻫﺪ ﺩﺍﺷﺖ.
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻣﺮﺍﺟﻌﻪ ﺑﻪ ﻣﺘﺨﺼﺼﺎﻥ ﺑﺮﺍﯼ ﻣﺸﺎﻭﺭﻩ ﺻﻮﺗﯽ
ﭼﺮﺍ ﺍﺳﺘﺎﻧﺪﺍﺭﺩﻫﺎﯼ ﺻﻮﺗﯽ ﺗﺎ ﺍﯾﻦ ﺍﻧﺪﺍﺯﻩ ﻣﻬﻢ ﻫﺴﺘﻨﺪ؟
ﺻﻔﺤﻪ / 16ﺷﻤﺎﺭﻩ 30
ﺳﯿﺴﺘﻢ ،ﻣﻮﺛﺮﻧﺪ.
ﺻﺪﺍ ﭼﯿﺴﺖ ﻭ ﭼﺮﺍ ﺁﻥ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﻣﯽﮔﯿﺮﯾﻢ؟ ﻫﺮﮔﻮﻧﻪ ﺗﻐﯿﯿﺮ ﻓﺸﺎﺭﯼ ﺭﺍ ﮐﻪ ﺑﻪ ﻭﺳﯿﻠﻪ ﮔﻮﺵ ﺍﻧﺴﺎﻥ ﺣﺲ ﺷﻮﺩ ﻣﯽﺗﻮﺍﻥ ﺻﺪﺍ ﺗﻠﻘﯽ ﮐﺮﺩ .ﺑﺮﺧﯽ ﺑﺮﺍﯼ ﮔﻮﺵ ﺧﻮﺷﺎﯾﻨﺪ ﺑﻮﺩﻩ ﻭ ﺑﺮﺧﯽ ﻣﺤﺮﮐﻨﺪ .ﺗﻤﺎﻡ ﮔﻮﺵﻫﺎ ،ﺍﺻﻮﺍﺕ ﺭﺍ ﺷﻨﯿﺪﻩ ﻭ ﺑﺎ ﺍﻧﺪﮐﯽ ﺗﻔﺎﻭﺕ ﺁﻥ ﺭﺍ ﺗﻔﺴﯿﺮ ﻣﯽﮐﻨﻨﺪ. ﺍﻧﺪﺍﺯﻩﮔﯿــﺮﯼ ﺍﺻﻮﺍﺕ ﺑﻪ ﻣﺎ ﺍﻣﮑﺎﻥ ﺗﻌﺮﯾــﻒ ﺩﻗﯿﻘﯽ ﺍﺯ ﺻﺪﺍﻫﺎﯼ ﻣﺨﺘﻠﻒ ﺩﺍﺩﻩ ﻭ ﻣﺒﻨﺎﯾﯽ ﺑﺮﺍﯼ ﻣﻮﺍﺭﺩ ﺯﯾﺮ ﺍﺳﺖ: • ﻣﻘﺎﯾﺴﻪ ﻣﺸﺘﺮﯼ ﺑﯿﻦ ﻣﺪﻝﻫﺎ ﻭ ﻣﺎﺭﮎﻫﺎﯼ ﺗﺠﺎﺭﯼ • ﻣﺸﮑﻼﺕ ﺗﺠﻬﯿﺰﺍﺕ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ • ﺗﺤﻠﯿﻞ ﻋﻠﻤﯽ ﺍﺻﻮﺍﺕ ﺁﺯﺍﺭﺩﻫﻨﺪﻩ • ﻣﺤﮑﯽ ﺑﺮﺍﯼ ﺑﻬﺒﻮﺩ ﮐﯿﻔﯿﺖ ﻣﺤﺼﻮﻝ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﻫﺮﺗﺰ ) :(Hzﻫﺮﺗﺰ ﻭﺍﺣﺪﯼ ﺍﺳﺖ ﮐﻪ ﺑﺮﺍﯼ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﻓﺮﮐﺎﻧﺲ )ﺗﻌﺪﺍﺩ ﺿﺮﺑﺎﻥ ﺩﺭ ﺛﺎﻧﯿﻪ( ﺻﺪﺍ ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷــﻮﺩ .ﻓﺮﮐﺎﻧﺲ ﯾﮏ ﺻﺪﺍ ،ﻣﺴــﺘﻘﯿﻤﺎ ﺑﻪ ﺩﺭﺟﻪ ﺻﺪﺍ ﺑﺮﻣﯽﮔﺮﺩﺩ .ﺑــﺮﺍﯼ ﻣﺜﺎﻝ ،ﻏﺮﺵ ﺭﻋﺪ ،ﺻﺪﺍﯾﯽ ﺑﺎ ﻓﺮﮐﺎﻧﺲ ﭘﺎﯾﯿﻦ ﺍﺳﺖ ،ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﺻﺪﺍﯼ ﺳﻮﺕ، ﺻﺪﺍﯾﯽ ﺑﺎ ﻓﺮﮐﺎﻧﺲ ﺑﺎﻻﺳﺖ. ﺩﺳـﯽﺑﻞ ) :(dBﺩﺳــﯽﺑﻞ ﺩﺍﻣﻨﻪ ﻧﻮﺳﺎﻧﺎﺕ ﻓﺸــﺎﺭ ﺻﻮﺗﯽ ﺭﺍ ﻣﺸــﺨﺺ ﻣﯽﮐﻨﺪ .ﺩﺳــﯽﺑﻞ ﻣﻌﻤﻮﻻ ﺑﺮﭘﺎﯾﻪ ﺑﻠﻨﺪﯼ ﺻﺪﺍﺳــﺖ. ﻫﻤﭽﻨﯿﻦ ﺑﺎﯾﺪ ﺑﺪﺍﻧﯿﻢ ﺍﻧﺪﺍﺯﻩﻫﺎﯼ ﺩﺳــﯽﺑﻞ ﺭﺍ ﻣﯽﺗﻮﺍﻥ ﺑﻪ ﮔﻮﻧﻪﺍﯼ ﻭﺯﻥﮐﺸــﯽ ﮐﺮﺩ ﮐﻪ ﺩﻗﺖ ﺑﯿﺸﺘﺮﯼ ﺩﺍﺷﺘﻪ ،ﺍﺻﻮﺍﺕ ﺭﺍ ﻣﺎﻧﻨﺪ ﮔﻮﺵ ﺍﻧﺴــﺎﻥ ﺳﻨﺠﯿﺪﻩ ﻭ ﺑﺮﺍﯼ ﺳﺎﺯﮔﺎﺭﯼ ،ﻓﺮﮐﺎﻧﺲﻫﺎﯼ ﺻﻮﺗﯽ ﺧﺎﺹ ﺭﺍ ﭘﺎﻻﯾﺶ ﮐﻨﺪ. ﻫﻤــﻪ ﺳــﺎﺯﻧﺪﮔﺎﻥ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾــﻪ ﻣﻄﺒﻮﻋــﯽ ﮐــﻪ ﺍﺯ ﺍﺳــﺘﺎﻧﺪﺍﺭﺩﻫﺎﯼ ) ARIﺍﺳــﺘﺎﻧﺪﺍﺭﺩ (ARI 95 - 270ﭘﯿــﺮﻭﯼ
ﺗﻠﻔﻦ88739880-2:
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﻭﺍﺣﺪﻫﺎﯼ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﺻﺪﺍ
ﻣﯽﮐﻨﻨﺪ ،ﺍﻧﺪﺍﺯﻩﻫﺎﯼ ﺻﻮﺗﯽ ﺭﺍ ﺑﻪ ﺻﻮﺭﺕ ﺩﺳﯽﺑﻞ ﻭﺯﻧﯽ ،ﺩﺳﯽﺑﻞ ،Aﻓﻬﺮﺳﺖ ﮐﺮﺩﻩﺍﻧﺪ. ﺑﺎﯾﺪ ﺑﻪ ﺧﺎﻃﺮ ﺩﺍﺷــﺖ ﮐﻪ ﺑــﻪ ﺩﻟﯿﻞ ﺁﻥﮐﻪ ﻫﯿﭻ ﺭﺍﻩ ﺳــﺎﺩﻩﺍﯼ ﺑﺮﺍﯼ ﻣﻘﺎﯾﺴﻪ ﺍﻧﺪﺍﺯﻩﻫﺎﯼ ﺩﺳﯽﺑﻞ ﻭ ﺩﺳﯽﺑﻞ Aﻭﺟﻮﺩ ﻧﺪﺍﺭﺩ ،ﺑﺮﺍﯼ ﻣﻘﺎﯾﺴﻪ ﻣﺎﻟﮑﺎﻥ ﺑﺎﯾﺪ ﻣﻘﺎﺩﯾﺮ ﺻﻮﺗﯽ ﺩﺭ ﻭﺍﺣﺪ ﯾﮑﺴﺎﻧﯽ ﺍﺯ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ، ﻓﻬﺮﺳﺖ ﺷﻮﻧﺪ.
ﺗﺎﺛﯿﺮﺍﺕ ﺻﺪﺍ ﺑﺮ ﮔﻮﺵ ﺍﻧﺴﺎﻥ ﯾﮏ ﮔﻮﺵ ﻣﻌﻤﻮﻟﯽ ﻭ ﺳــﺎﻟﻢ ،ﻓﺮﮐﺎﻧﺲﻫﺎﯼ ﺑﯿﻦ 20ﻫﺮﺗﺰ ﺗﺎ 20ﮐﯿﻠﻮﻫﺮﺗﺰ ،ﯾﺎ ﺑﻪ ﺻﻮﺭﺗﯽ ﺁﺷــﻨﺎﺗﺮ ﺗﺎ ﺁﺳــﺘﺎﻧﻪ ﺩﺭﺩ ﯾﻌﻨﯽ ﺣﺪﻭﺩ 120ﺩﺳﯽﺑﻞ ﯾﺎ ﺑﯿﺶ ﺍﺯ ﺁﻥ ﺭﺍ ﺣﺲ ﻣﯽﮐﻨﺪ .ﮔﻮﺵ ﮐﻮﭼﮏﺗﺮﯾﻦ ﺗﻐﯿﯿﺮﯼ ﺩﺭ ﺻﺪﺍ ﺭﺍ ﺗﺎ ﺣﺪﻭﺩ 3ﺩﺳــﯽﺑﻞ ﺣﺲ ﻣﯽﮐﻨﺪ .ﺑﻪ ﺩﻟﯿﻞ ﺷــﯿﻮﻩ ﺗﻔﺴﯿﺮ ﺻﺪﺍ ﺑﻪ ﻭﺳﯿﻠﻪ ﮔﻮﺵ ،ﺍﻓﺰﺍﯾﺶ 6ﺩﺳﯽﺑﻞ ،ﺩﻭﺑﺮﺍﺑﺮ ﻣﻘﺪﺍﺭﯼ ﮐﻪ ﮔــﻮﺵ ﺣﺲ ﻣﯽﮐﻨﺪ ،ﺑﺎﯾﺪ ﺑﻪ ﺣﺪﻭﺩ 10ﺩﺳــﯽﺑﻞ ﺑﺮﺳﺪ ﺗﺎ ﺑﻠﻨﺪﯼ ﺻﺪﺍ ﺩﻭﺑﺮﺍﺑﺮ ﺷﻮﺩ. ﺑﺮﺍﯼ ﭘﯿﭽﯿﺪﻩ ﺷــﺪﻥ ﻫﺮﭼﻪ ﺑﯿﺸﺘﺮ ﺍﯾﻦ ﻣﻮﺿﻮﻉ ،ﺷﯿﻮﻩﺍﯼ ﮐﻪ ﺻﺪﺍ ﺑﻪ ﮔﻮﺵ ﻣﯽﺭﺳﺪ ،ﺗﺤﺖ ﺗﺎﺛﯿﺮ ﻋﻮﺍﻣﻞ ﺯﯾﺎﺩﯼ ﺍﺳﺖ: • ﻫﻤــﻪ ﮔﻮﺵﻫﺎ ﻧﺴــﺒﺖ ﺑــﻪ ﻫﻤــﻪ ﻓﺮﮐﺎﻧﺲﻫﺎ ﺣﺴــﺎﺱ ﻧﯿﺴﺘﻨﺪ. • ﺍﺻﻮﺍﺗــﯽ ﺑﺎ ﻓﺮﮐﺎﻧﺲﻫــﺎﯼ ﭘﺎﯾﯿﻦ ،ﺑﺎﯾﺪ ﺩﺳــﯽﺑﻞ ﺑﺎﻻﺗﺮﯼ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻨﺪ ﺗﺎ ﻫﻤﺎﻥ ﺑﻠﻨﺪﯼ ﻧﺴﺒﯽ ﺭﺍ ﺑﺮﺳﺎﻧﻨﺪ. • ﺍﺻﻮﺍﺕ ﺿﺮﺑﻪﺍﯼ ﯾﺎ ﺍﺻﻮﺍﺗــﯽ ﮐﻪ ﺑﻪ ﻃﻮﺭ ﻧﺎﮔﻬﺎﻧﯽ ﺑﻪ ﻭﺟﻮﺩ ﻣﯽﺁﯾﻨﺪ )ﻣﺎﻧﻨﺪ ﺑﺮﺧﻮﺭﺩ ﭼﮑﺶ ﺑﺮ ﻣﯿﺦ( ،ﻣﻤﮑﻦ ﺍﺳﺖ ﺻﺪﺍﯾﯽ ﺑﻪ ﺑﻠﻨﺪﯼ ﺻﺪﺍﯼ ﺗﻮﻟﯿﺪﺷﺪﻩ ﺑﺎ ﺩﺳﯽﺑﻞ ﭘﺎﯾﯿﻦﺗﺮ ﻧﺪﺍﺷﺘﻪ ﺑﺎﺷﻨﺪ؛ ﻭﻟﯽ ﺩﺭ ﺩﻭﺭﻩ ﻃﻮﻻﻧﯽﺗﺮﯼ ﭘﺪﯾﺪ ﻣﯽﺁﯾﻨﺪ.
ﭼﮕﻮﻧﮕﯽ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﺍﺻﻮﺍﺕ ﺗﺼﻮﯾﺮ ) (1ﺗﺎﺳﯿﺴﺎﺕ ﻣﻬﻨﺪﺳﯽ ﺍﯾﻨﺪﯾﺎﻧﺎﭘﻮﻟﯿﺲ ﺣﺎﻭﯼ ﺍﺗﺎﻕ ﺻﻮﺗﯽ ﭘﺮﺍﻧﻌﮑﺎﺳﯽ ﺑﺎ ﭘﺮﻩﺍﯼ ﮔﺮﺩﻧﺪﻩ ﺑﺮﺍﯼ ﺑﺮﺭﺳﯽ ﺩﺭﺟﺎﺕ ﺻﻮﺗﯽ ﺗﺠﻬﯿﺰﺍﺕ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺍﺳﺖ. ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺑﺮﺍﯼ ﺍﻃﻤﯿﻨﺎﻥ ﺍﺯ ﺑﯿﺸــﺘﺮﯾﻦ ﺩﻗﺖ ﻭ ﺷﻔﺎﻑ ﺑﻮﺩﻥ ﺩﺭ ﻣﻘﺎﯾﺴﻪ ﺑﺎ ﺳﺎﺯﻧﺪﮔﺎﻥ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺗﺠﻬﯿﺰﺍﺗﯽ ﮐﻪ ﻣﺸــﺎﺑﻪ ﮔﻮﺵ ﺍﻧﺴــﺎﻥ ﻋﻤﻞ ﻣﯽﮐﻨﻨﺪ ،ﺑــﻪ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﺻﺪﺍ ﻣﯽﭘﺮﺩﺍﺯﻧﺪ .ﺍﻃﻼﻋﺎﺕ ﺻﻮﺗﯽ ﺩﺭ ﻣﺤﯿﻄﯽ ﺑﻪﺷﺪﺕ ﮐﻨﺘﺮﻝﺷﺪﻩ ﮐﻪ ﻣﻌﻤﻮﻻ ﺍﺗﺎﻗﯽ ﺑﺴــﺘﻪ ﻭ ﭘﺮﺍﻧﻌﮑﺎﺱ ﺑﺎ ﭘﺮﻩﺍﯼ ﮔﺮﺩﺍﻥ ،ﺗﺠﻬﯿﺰﺍﺗﯽ ﮐﻪ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 17ﺷﻤﺎﺭﻩ 30
ﻭﺍﺣﺪﻫــﺎﯼ ﮐﺮﯾﺮ ﺑــﻪ ﻃﻮﺭ ﻣﺸــﺎﺑﻪ ﻋﻤﻞ ﮐــﺮﺩﻩ ﻭ ﺻﺪﺍﯾﯽ ﻣﺎﻧﻨﺪ ﻣﺤﺼﻮﻝ ﺭﻗﯿﺐ ﺗﻮﻟﯿﺪ ﻣﯽﮐﻨﻨﺪ.
ﭼﮕﻮﻧـﻪ ﺍﯾﻦ ﻣﺴـﺎﯾﻞ ﺑﻪ ﺳﯿﺴـﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺧﺎﻧﮕﯽ ﻣﺮﺑﻮﻁ ﻣﯽﺷﻮﺩ؟
ﺗﺼﻮﯾﺮ ) (2ﺍﺗﺎﻕ ﺻﻮﺗﯽ ﭘﺮﺍﺭﺗﻌﺎﺵ ﺁﺯﻣﺎﯾﺸﮕﺎﻩ ﺻﺪﺍ ﻣﻄﺎﺑﻖ ﺍﺳﺘﺎﻧﺪﺍﺭﺩﻫﺎﯼ ﺻﻮﺗﯽ ARIﺑﻮﺩﻩ ﻭ ﻭﺳﯿﻠﻪ ﺳﻨﺠﺶ ﺻﺪﺍ ﺍﺳﺖ ،ﺟﻤﻊ ﺁﻭﺭﯼ ﻣﯽﺷــﻮﻧﺪ .ﺑﻪ ﺩﻟﯿﻞ ﻣﺤﯿﻂ ﮐﻨﺘﺮﻝﺷﺪﻩ ،ﻫﺮ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﻣﺤﯿﻄﯽ ﮐﻪ ﺑﺮ ﺍﺳــﺎﺱ ﻭﺍﺣﺪﻫﺎﯼ ﺩﺳﯽﺑﻞ Aﺍﻧﺠﺎﻡ ﺷــﻮﺩ ،ﺩﻗﯿﻘﺎ ﻣﻨﻄﺒﻖ ﺑﺮ ﻓﻬﺮﺳــﺖ ﻣﻮﺿﻮﻋﯽ ﺗﺠﻬﯿﺰﺍﺕ ﻧﯿﺴﺖ.
• ﺩﻣﺎ • ﺑﺎﺩ • ﺭﻃﻮﺑﺖ • ﻫﺮ ﺻﺪﺍﯼ ﺧﺎﺭﺟﯽ ﺩﯾﮕﺮﯼ
ﺻﺪﺍﯼ ﻧﺎﺷﯽ ﺍﺯ ﭼﻨﺪﯾﻦ ﻭﺍﺣﺪ ﺩﺭ ﺷــﺮﺍﯾﻄﯽ ﮐﻪ ﺗﺼﻤﯿﻢ ﺑﻪ ﺍﻧﺪﺍﺯﻩﮔﯿﺮﯼ ﺻﺪﺍﯼ ﺑﯿﺶ ﺍﺯ ﯾﮏ ﻭﺳــﯿﻠﻪ ﺩﺍﺭﯾﻢ ،ﻧﻤﯽﺗﻮﺍﻥ ﺑﻪﺳﺎﺩﮔﯽ ﺩﺳــﯽﺑﻞ Aﺁﻥﻫﺎ ﺭﺍ ﺑﺎ ﻫﻢ ﺟﻤــﻊ ﻭ ﺻﺪﺍﯼ ﺣﺎﺻﻞ ﺭﺍ ﺗﺨﻤﯿﻦ ﺯﺩ .ﺑﻪ ﺩﻟﯿﻞ ﺁﻥﮐﻪ ﻭﺍﺣﺪﻫﺎﯼ ﺩﺳــﯽﺑﻞ ﺑﺮﭘﺎﯾﻪ ﻧﺴﺒﺖ ﻟﮕﺎﺭﯾﺘﻤﯽ ﻫﺴــﺘﻨﺪ ،ﺍﻓﺰﻭﺩﻥ ﺩﻭ ﻣﻘﺪﺍﺭ،
ﺭﻗﯿﺐ ﺑﺎ ﻧﺸــﺎﻥ ﺩﺍﺩﻥ ﺍﯾﻦ ﻣﻄﻠﺐ ﺑﻬﺮﻩ ﻣﯽﺑﺮﺩ ﮐﻪ ﭼﮕﻮﻧﻪ ﺑﺮﺧﯽ
ﻣﺎﺷﯿﻦ ﭼﻤﻦﺯﻧﯽ
ﺳﺸﻮﺍﺭ
ﯾﺨﭽﺎﻝ
ﻭﺍﺣﺪ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻣﻌﻤﻮﻝ
ﻓﻦ )ﭘﻨﮑﻪ(
ﻣﮑﺎﻟﻤﻪ
ﺗﻠﻔﻦ55401278 :
ﺍﺩﺑﯿﺎﺕ ﻓﺮﻭﺵ ﻣﺎ ﺍﺯ ﺑﻠﻨﺪﯼ ﻧﺴــﺒﯽ ﺻﺪﺍﯼ ﺑﻌﻀﯽ ﺍﺯ ﻣﺤﺼﻮﻻﺕ
ﻧﺎﻣﺤﺪﻭﺩ *21
ﺗﺼﻮﯾﺮ ) (3ﻣﻘﺎﯾﺴﻪ ﺩﺭﺟﺎﺕ ﺻﻮﺗﯽ )ﺩﺳﯽﺑﻞ( ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻧﯿﺎﺯﻣﻨﺪ ﻣﺤﺎﺳﺒﺎﺕ ﺯﯾﺎﺩﯼ ﺍﺳﺖ .ﺑﺎﯾﺪ ﺩﺍﻧﺴﺖ ،ﺩﺭ ﺑﺮﺧﯽ ﻣﻮﺍﺭﺩ،
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻋﺒﺎﺭﺗﻨﺪ ﺍﺯ:
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻣﺘﻐﯿﺮﻫﺎﯾــﯽ ﮐﻪ ﺑﺮ ﻫﺮﮔﻮﻧﻪ ﺍﻧﺪﺍﺯﻩﮔﯿــﺮﯼ ﻣﺤﯿﻄﯽ ﺍﺛﺮ ﻣﯽﮔﺬﺍﺭﻧﺪ
ﺑﻪ ﺩﻟﯿــﻞ ﺁﻥﮐﻪ ﺳــﺎﺯﻧﺪﮔﺎﻥ ،ﺍﻃﻼﻋﺎﺕ ﺻﻮﺗــﯽ ﻣﺤﺼﻮﻻﺕ ﺧــﻮﺩ ﺭﺍ ﺗﻬﯿــﻪ ﻣﯽﮐﻨﻨﺪ ،ﻫﯿﭻﮔﺎﻩ ﺭﺍﺿﯽ ﮐﺮﺩﻥ ﻣﺸــﺘﺮﯼ ﺩﺭﺑﺎﺭﻩ ﺍﯾﻦﮐﻪ ﻣﯽﺗﻮﺍﻥ ﻣﻘﺎﯾﺴﻪ ﺩﻗﯿﻘﯽ ﺑﯿﻦ ﻣﺤﺼﻮﻻﺕ ﺍﻧﺠﺎﻡ ﺩﺍﺩ ،ﺁﺳﺎﻥ ﻧﯿﺴــﺖ .ﻫﺮﭼﻨﺪ ﺍﺯ ﺁﻧﺠﺎ ﮐﻪ ﮐﺮﯾﺮ ﺑﺮ ﺍﺳﺎﺱ ﺍﺳﺘﺎﻧﺪﺍﺭﺩﻫﺎﯼ ARI ﻋﻤﻞ ﮐﺮﺩﻩ ،ﺩﺭ ﻣﻮﺍﺭﺩ ﺯﯾﺮ ﻣﯽﺗﻮﺍﻥ ﻣﻘﺎﯾﺴﻪ ﺩﻗﯿﻘﯽ ﺍﻧﺠﺎﻡ ﺩﺍﺩ: • ﻣــﺎﺭﮎ ﺗﺠﺎﺭﯼ ﺭﻗﯿﺐ ﻧﯿﺰ ﺍﺯ ﺍﺳــﺘﺎﻧﺪﺍﺭﺩﻫﺎﯼ ARIﺗﺒﻌﯿﺖ ﮐﻨﺪ. • ﻣﻘﺎﺩﯾﺮ ﻣﻮﺭﺩ ﺭﻗﺎﺑﺖ ﺑﻪ ﺻﻮﺭﺕ ﺩﺳــﯽﺑﻞ Aﻓﻬﺮﺳﺖ ﺷﺪﻩ ﺑﺎﺷﻨﺪ. • ﺩﺭﺻﻮﺭﺗﯽ ﮐﻪ ﺑﺮ ﺍﺳــﺎﺱ ﺩﺳﯽﺑﻞ Aﻓﻬﺮﺳﺖ ﻧﺸﺪﻩ ﺑﺎﺷﺪ، ﺑﺮﺍﯼ ﺗﻄﺒﯿﻖ ﺑﺎ ﺁﻥ ﺑﺎ ﺗﻮﺯﯾﻊﮐﻨﻨﺪﻩ ﯾﺎ ﻓﺮﻭﺷﻨﺪﻩ ﺁﻥ ﻣﺤﺼﻮﻝ ﺗﻤﺎﺱ ﺑﮕﯿﺮﯾﺪ. • ﺍﮔﺮ ﻣﻘﺎﺩﯾﺮ ﻣﻮﺭﺩ ﺭﻗﺎﺑﺖ ﻣﻄﺎﺑﻖ ﺳﻄﺢ ﺻﺪﺍ ﻓﻬﺮﺳﺖ ﻧﺸﺪﻩ ﺑﺎﺷﺪ ،ﺑﺮﺍﯼ ﺗﻄﺒﯿﻖ ﺑﺎ ﺁﻥ ﺑﺎ ﺗﻮﺯﯾﻊﮐﻨﻨﺪﻩ ﯾﺎ ﻓﺮﻭﺷﻨﺪﻩ ﺁﻥ ﻣﺤﺼﻮﻝ ﺗﻤﺎﺱ ﺑﮕﯿﺮﯾﺪ. ﺳﭙﺲ ﻭﻗﺘﯽ ﮐﺮﯾﺮ ﺍﻧﺘﺨﺎﺏ ﺷﺪ ،ﮔﺎﻡ ﺑﻌﺪﯼ ﺭﺍ ﺑﺮﺩﺍﺭﯾﺪ. ﺑــﻪ ﺁﻥﻫﺎ ﮐﻤﮏ ﮐﻨﯿﺪ ﺗــﺎ ﺁﺭﺍﻡﺗﺮﯾﻦ ﻣﺤﺼﻮﻝ ﻣﻄﺎﺑﻖ ﻧﯿﺎﺯﻫﺎ ﻭ ﺑﻮﺩﺟﻪﺷﺎﻥ ﺭﺍ ﺍﻧﺘﺨﺎﺏ ﮐﻨﻨﺪ. • ﺩﺭﺻــﻮﺭﺕ ﻣﻤﮑﻦ ﺑﻪ ﺁﻥﻫﺎ ﮐﻤﮏ ﮐﻨﯿﺪ ﺗــﺎ ﺑﻬﺘﺮﯾﻦ ﻣﺤﻞ ﻧﺼــﺐ ﺭﺍ ﺑﺮﺍﯼ ﮐﺎﻫﺶ ﺗﺎﺛﯿﺮ ﺻﺪﺍﯼ ﺗﺠﻬﯿﺰﺍﺕ ﺩﺭ ﻃﻮﻝ ﻋﻤﻠﮑﺮﺩ، ﺗﻌﯿﯿﻦ ﮐﻨﻨﺪ. • ﺍﺯ ﻃﺮﯾﻖ ﻃﺮﺡ ﻧﮕﻬﺪﺍﺭﯼ ﻣﯽﺗﻮﺍﻥ ﺳﯿﺴﺘﻢ ﺭﺍ ﺑﺪﻭﻥ ﻣﺸﮑﻞ ﺍﺳﺘﻔﺎﺩﻩ ﻭ ﺗﺎ ﺣﺪ ﺍﻣﮑﺎﻥ ﺁﺭﺍﻡ ﻧﮕﺎﻩ ﺩﺍﺷﺖ. ﺑﺎ ﺍﯾﺠﺎﺩ ﯾﮏ ﺧﻂ ﺍﺭﺗﺒﺎﻃﯽ ﺑﺎ ﻣﺎﻟﮏ ﻭ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺍﻃﻼﻋﺎﺕ ﺍﯾﻦ ﺟﺰﻭﻩ ﺑﺮﺍﯼ ﺍﯾﺠﺎﺩ ﺍﻃﻤﯿﻨﺎﻥ ﻭ ﺩﺍﺩﻥ ﭘﺎﺳﺦﻫﺎﯾﯽ ﺭﺿﺎﯾﺖﺑﺨﺶ ﺑــﻪ ﺳــﻮﺍﻻﺗﯽ ﮐﻪ ﻣﻤﮑــﻦ ﺍﺳــﺖ ﺩﺭ ﺯﻣﯿﻨﻪ ﺻﺪﺍ ﻣﻄﺮﺡ ﺷــﻮﺩ، ﻣﯽﺗﻮﺍﻧﯿﺪ ﺷﺎﻧﺲ ﺧﻮﺩ ﺭﺍ ﺩﺭ ﺭﺿﺎﯾﺖ ﻣﺸﺘﺮﯼ ﺍﻓﺰﺍﯾﺶ ﺩﻫﯿﺪ.
ﺻﻔﺤﻪ / 18ﺷﻤﺎﺭﻩ 30
ﺗﺨﺼﺼﻰ
ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﻳﺦﺯﺩﮔﻰ ﻭ ﻛﺎﻫﺶ ﺻﺪﺍﻯ ﺳﻴﺴﺘﻢﻫﺎﻯ ﺁﺏ ﺳﺮﺩ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ
ﻣﻘﺪﻣﻪ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺁﺏ ﺳــﺮﺩﯼ ﮐﻪ ﺍﺯ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﺳــﺮﺩ ﺑﯿﺮﻭﻥ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﮐﻨﻨﺪ ،ﺑﺎ ﭼﺎﻟﺶﻫﺎﯾﯽ ﻣﻮﺍﺟﻪ ﻫﺴﺘﻨﺪ.
ﺗﻤــﺎﻡ ﺍﺟﺰﺍﯼ ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺩﺭ ﺑﯿﺮﻭﻥ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﻧﺪ .ﺍﯾﻦ ﺑﻪ ﺍﯾﻦ ﻣﻌﻨﯽ ﺍﺳﺖ ﮐﻪ ﺟﻌﺒﻪ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ،ﻭﺳﯿﻠﻪﺍﯼ ﮐﻪ ﺳﯿﺎﻝ ﺩﺭ ﺟﺮﯾﺎﻥ
ﺍﻧﺘﺸﺎﺭ ﺳــﺮﻭﺻﺪﺍ ﺩﺭ ﺗﻤﺎﻡ ﭼﯿﻠﺮﻫﺎﯼ ﺑﯿﺮﻭﻧﯽ ﻭﺟﻮﺩ ﺩﺍﺷﺘﻪ ﻭ
ﺭﺍ ﺧﻨــﮏ ﻣﯽﮐﻨﺪ ،ﺩﺭﻣﻌﺮﺽ ﻫﻮﺍﯼ ﺳــﺮﺩ ﻣﺤﯿﻂ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ.
ﺻﺪﺍﯼ ﭘﺪﯾﺪﺁﻣﺪﻩ ﺗﻮﺳــﻂ ﺗﺠﻬﯿﺰﺍﺕ ،ﺑﺎﻋﺚ ﻣﺰﺍﺣﻤﺖ ﺳﺎﮐﻨﺎﻥ ﻭ
ﺍﮔﺮ ﺳــﯿﺎﻝ ﺩﺭ ﮔﺮﺩﺵ ،ﺁﺏ ﺑﺎﺷﺪ ،ﻭﻗﺘﯽ ﺩﻣﺎﯼ ﺑﯿﺮﻭﻥ ﺑﻪ ﮐﻤﺘﺮ ﺍﺯ
ﻫﻤﺴﺎﯾﮕﺎﻥ ﺁﻥﻫﺎ ﻣﯽﺷﻮﺩ.
32ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺮﺳﺪ ،ﺩﺭﺻﻮﺭﺗﯽ ﮐﻪ ﺣﻔﺎﻇﺖ ﺧﺎﺻﯽ ﺩﺭﺑﺮﺍﺑﺮ
ﻋﻼﻭﻩ ﺑﺮ ﺍﯾﻦ ،ﭼﯿﻠﺮﻫﺎﯼ ﺑﯿﺮﻭﻧﯽ ﻧﺼﺐﺷﺪﻩ ﺩﺭ ﻧﻮﺍﺣﯽ ﺷﻤﺎﻟﯽ،
ﯾﺦﺯﺩﮔــﯽ ﺻﻮﺭﺕ ﻧﭙﺬﯾﺮﺩ ،ﯾــﺦ ﻣﯽﺯﻧﺪ .ﺩﺭ ﺑﺴــﯿﺎﺭﯼ ﮐﺎﺭﺑﺮﺩﻫﺎ،
ﺗﺤﺖ ﺗﺎﺛﯿﺮ ﻫﻮﺍﯼ ﺳــﺮﺩ ﺑﯿﺮﻭﻥ ﻭ ﻫﺰﯾﻨﻪﻫﺎﯼ ﻧﺎﺷــﯽ ﺍﺯ ﻣﺤﺎﻓﻈﺖ
ﺍﻓﺰﻭﺩﻥ ﺿﺪﯾﺦ ﺑﻪ ﺳــﯿﺎﻝ ،ﺍﺣﺘﻤﺎﻝ ﯾﺦﺯﺩﮔﯽ ﺭﺍ ﮐﺎﻫﺶ ﻣﯽﺩﻫﺪ.
ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ،ﻫﺴــﺘﻨﺪ .ﺭﺍﻩﺣﻞﻫــﺎﯼ ﺿﺪﯾﺦﺯﺩﮔﯽ ﻣﯽﺗﻮﺍﻧﻨﺪ
ﻫﻤﺎﻥﻃﻮﺭ ﮐﻪ ﺍﺷــﺎﺭﻩ ﺷﺪ ،ﺍﻧﺘﺸﺎﺭ ﺻﺪﺍ ﺍﺯ ﭼﯿﻠﺮ ﻭ ﻣﻀﺮﺍﺕ ﺿﺪﯾﺦ
ﺍﯾﻤﻨﯽ ﺑﺨﺶ ﺑﺎﺷﻨﺪ؛ ﺍﻟﺒﺘﻪ ﺩﺭ ﺍﯾﻦ ﺯﻣﯿﻨﻪ ﺑﺎﯾﺪ ﻣﻼﺣﻈﺎﺗﯽ ﺩﺭﻧﻈﺮ
ﺩﺭ ﺍﯾﻦ ﺳﯿﺴﺘﻢ ﺁﺏ ﺳﺮﺩ ،ﻭﺟﻮﺩ ﺧﻮﺍﻫﺪ ﺩﺍﺷﺖ.
ﮔﺮﻓﺘﻪ ﺷــﻮﺩ .ﺑﺮﺧﯽ ﺳــﯿﺎﻻﺕ ﺿﺪﯾﺦﺯﺩﮔﯽ ﺧﻄﺮﻧﺎﮎ ﻫﺴــﺘﻨﺪ. ﻫﻤﭽﻨﯿﻦ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺿﺪﯾﺦ ،ﻭﯾﺴﮑﻮﺯﯾﺘﻪ ﺳﯿﺎﻝ ﺭﺍ ﺍﻓﺰﺍﯾﺶ ﺩﺍﺩﻩ
ﭼﯿﻠﺮ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ
ﻭ ﺑﺎﻋﺚ ﺍﻓﺰﺍﯾﺶ ﺍﻧــﺮﮊﯼ ﭘﻤﭙﺎﮊ ،ﮐﺎﻫﺶ ﻗﺎﺑﻠﯿﺖ ﺍﻧﺘﻘﺎﻝ ﺣﺮﺍﺭﺗﯽ ﻭ
ﭼﯿﻠــﺮ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ،ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺍﺳــﺖ ﮐﻪ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺁﻥ
ﭘﺎﯾﯿﻦ ﺁﻣﺪﻥ ﮐﺎﺭﺍﯾﯽ ﻣﯽﺷﻮﺩ .ﻋﻤﻠﮑﺮﺩ ﺩﺭ ﺯﻣﯿﻨﻪ ﺍﻧﺮﮊﯼ ،ﻣﻮﺿﻮﻋﯽ
ﺩﻭﺭ ﺍﺯ ﭼﯿﻠﺮ ﺑﯿﺮﻭﻧﯽ ﺑﻮﺩﻩ ﻭ ﺩﺭ ﺩﺍﺧﻞ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ .ﺧﻄﻮﻁ ﻣﺎﯾﻊ
ﻧﯿﺴــﺖ ﮐﻪ ﺍﻏﻠﺐ ﻣﺎﻟﮑﺎﻥ ﻧﺴﺒﺖ ﺑﻪ ﺁﻥ ﺑﯽﺗﻔﺎﻭﺕ ﺑﺎﺷﻨﺪ ،ﺑﻪﻭﯾﮋﻩ
ﺳﺮﻣﺎﯾﺸﯽ ﻭ ﻣﮑﺶ ﺑﺎﯾﺪ ﺩﺭ ﻫﺮ ﭘﺮﻭﮊﻩ ﺗﻮﺳﻂ ﻣﻘﺎﻃﻌﻪﮐﺎﺭ ،ﺩﺭ ﻣﺤﻞ
ﺍﮔﺮ ﺑﻪ ﻧﮑﺎﺕ ﺗﺎﯾﯿﺪﯾﻪ ،LEEDﺗﻮﺟﻪ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻨﺪ.
ﻃﺮﺍﺣﯽ ﻭ ﻧﺼﺐ ﺷﻮﻧﺪ .ﺍﯾﻦ ﻃﺮﺍﺣﯽ ،ﻣﺤﯿﻂ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺭﺍ ﺍﺯ ﻫﻮﺍﯼ
ﺍﯾــﻦ ﻣﻘﺎﻟﻪ ،ﺍﻟﺰﺍﻣﺎﺕ ﻣﺤﺎﻓﻈﺖ ﺩﺭ ﺑﺮﺍﺑــﺮ ﯾﺦﺯﺩﮔﯽ ﻭ ﮐﺎﻫﺶ
ﺳــﺮﺩ ﺑﯿﺮﻭﻥ ﺩﺭ ﺍﻣــﺎﻥ ﻧﮕﻪ ﻣﯽﺩﺍﺭﺩ؛ ﺍﻟﺒﺘﻪ ﺳــﺮﻭﺻﺪﺍﯼ ﺑﯿﺮﻭﻥ،
ﺳــﺮﻭﺻﺪﺍ ﺩﺭ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺁﺏ ﺳﺮﺩ ﺭﺍ ﺑﺮﺭﺳﯽ ﻣﯽﮐﻨﺪ ﻭ ﺭﺍﻩﺣﻠﯽ
ﺧﻄﻮﻁ ﻣﮑﺶ ﺑﺴﺘﻪﺷــﺪﻩ ،ﺩﺳﺘﺮﺳــﯽ ﺑﻪ ﮐﻤﭙﺮﺳــﻮﺭ ﻭ ﺍﻟﺰﺍﻣﺎﺕ
ﺭﺍ ﻧﺸﺎﻥ ﻣﯽﺩﻫﺪ ﮐﻪ ﻣﯽﺗﻮﺍﻥ ﺑﺮﺍﯼ ﺣﺴﺎﺳﯿﺖ ﺩﺭ ﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ﻭ
ﻣﺮﺑﻮﻁ ﺑﻪ ﻓﻀﺎﯼ ﺩﺍﺧﻠﯽ ،ﻫﻤﻪ ﺑﺎﯾﺪ ﺩﺭﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮﻧﺪ.
ﺳﺮﻭﺻﺪﺍﯼ ﺗﻮﻟﯿﺪﺷﺪﻩ ﺍﺯ ﺍﺟﺰﺍﯼ ﺳﯿﺴﺘﻢ ،ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ.
ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ﺩﺭ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ،ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﺣﺎﻟﺖﻫﺎﯼ ﭼﯿﻠﺮ ﭼﻪ ﺗﻔﺎﻭﺕﻫﺎﯾﯽ ﺑﯿﻦ ﭼﯿﻠﺮ ﻫﻮﺍﺳــﺮﺩ ،ﭼﯿﻠﺮ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﻭ
ﻭ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎ ﺩﺭ ﺩﺍﺧﻞ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﻧﺪ .ﺍﯾﻦ ﺳﯿﺴــﺘﻢ ،ﻣﺤﯿﻂ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺭﺍ ﺍﺯ ﻫﻮﺍﯼ ﺳــﺮﺩ ﺑﯿﺮﻭﻥ ﺩﺭ ﺍﻣــﺎﻥ ﻧﮕﻪ ﻣﯽﺩﺍﺭﺩ .ﺑﺎ ﻗﺮﺍﺭ
ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻭﺟﻮﺩ ﺩﺍﺭﺩ؟ ﯾﮑﯽ ﺍﺯ ﺭﺍﻩﻫﺎﯼ ﭘﺎﺳــﺦ ﺑﻪ ﺍﯾﻦ ﭘﺮﺳــﺶ ،ﻣﺤــﻞ ﻗﺮﺍﺭ ﮔﺮﻓﺘﻦ
ﮔﺮﻓﺘﻦ ﮐﻤﭙﺮﺳــﻮﺭ ﺩﺭ ﺩﺍﺧﻞ ،ﮐﻨﺘﺮﻝ ﺻﺪﺍ ﻭ ﮐﺎﺭ ﺑﺎ ﺁﻥ ،ﺁﺳــﺎﻥﺗﺮ
ﺍﺟــﺰﺍﯼ ﭼﯿﻠﺮ ﺑﻪ ﺻﻮﺭﺕ ﻧﺸﺎﻥﺩﺍﺩﻩﺷــﺪﻩ ﺩﺭ ﺗﺼﺎﻭﯾــﺮ )(2) ،(1
ﻣﯽﺷــﻮﺩ .ﮐﻨﺪﺍﻧﺴــﻮﺭﯼ ﻫﻮﺍﯾﯽ ﮐــﻪ ﺩﺭ ﺑﯿﺮﻭﻥ ﻗــﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ،
ﻭ ) (3ﺍﺳــﺖ .ﺩﺭ ﺍﯾﻦ ﺗﺼﺎﻭﯾﺮ ،ﺍﺟــﺰﺍﯼ ﻗﺮﺍﺭﮔﺮﻓﺘﻪ ﺩﺭ ﺩﺍﯾﺮﻩ ﻗﺮﻣﺰ
ﮐﻮﭼﮏﺗﺮ ﺑﻮﺩﻩ ،ﺻﺪﺍﯼ ﮐﻤﺘﺮﯼ ﺩﺍﺷــﺘﻪ ﻭ ﺩﺭ ﻣﻘﺎﯾﺴﻪ ﺑﺎ ﭼﯿﻠﺮﯼ
ﺑﺮﺭﺳﯽ ﺷﺪﻩ ﻭ ﺑﺴﺘﻪﺑﻨﺪﯼ ﺗﻮﺳﻂ ﮐﺎﺭﺧﺎﻧﻪ ﺍﻧﺠﺎﻡ ﻣﯽﺷﻮﻧﺪ.
ﻫﻮﺍﯾﯽ ﺑﺎ ﻇﺮﻓﯿﺖ ﻣﺸﺎﺑﻪ ،ﻭﺯﻥ ﮐﻤﺘﺮﯼ ﻧﯿﺰ ﺩﺍﺭﺩ.
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 19ﺷﻤﺎﺭﻩ 30
ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﺁﯾﺎ ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺑﺎ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﻣﻨﺎﺳﺐ ﺍﺳﺖ؟
ﭼﯿﻠﺮﻫﺎﯼ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﻭ ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺧﻂ ﻣﺎﯾﻊ
ﺧﻂ ﮔﺎﺯ ﮔﺮﻡ
ﺑﯿﺮﻭﻥ
ﻫﻤﺎﻥﻃﻮﺭ ﮐﻪ ﺩﺭ ﺑﺎﻻ ﻣﻄﺮﺡ ﺷــﺪ ،ﯾﮑــﯽ ﺍﺯ ﺭﺍﻩﻫﺎﯼ ﻣﻘﺎﺑﻠﻪ ﮐﻤﭙﺮﺳﻮﺭ
ﺑــﺎ ﯾﺦﺯﺩﮔﯽ ،ﻗــﺮﺍﺭﺩﺍﺩﻥ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺩﺭ ﺩﺍﺧﻞ ﺍﺳــﺖ ،ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ﻭ ﺑﺨﺶ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﺩﺭ ﺑﯿﺮﻭﻥ ﺑﺎﻗﯽ ﻣﯽﻣﺎﻧﻨﺪ.
ﺷﯿﺮ ﺍﻧﺒﺴﺎﻁ
ﺧﻂ ﻣﮑﺶ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﺍﯾﻦ ﺍﺟﺰﺍ ﺑﻪ ﻭﺳﯿﻠﻪ ﻣﮑﺶ ﻧﺼﺐﺷﺪﻩ ﺩﺭ ﻣﺤﯿﻂ ﻭ ﻟﻮﻟﻪﮐﺸﯽ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﯿﻦ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻭ ﮐﻤﭙﺮﺳﻮﺭ /ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﯿﺮﻭﻥ ،ﺑﻪ ﻫﻢ ﻣﺘﺼﻞ ﻣﯽﺷﻮﻧﺪ )ﺗﺼﻮﯾﺮ .(4
ﺗﺼﻮﯾﺮ ) (1ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ
ﻫﺮﭼﻨﺪ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺍﯾﻦ ﺳﯿﺴــﺘﻢ ﺑﺮﺍﯼ ﻣﻘﺎﺑﻠﻪ ﺑﺎ ﯾﺦﺯﺩﮔﯽ، ﻭﺳﻮﺳــﻪﺍﻧﮕﯿﺰ ﺍﺳــﺖ ،ﺍﻟﺰﺍﻣﺎﺕ ﻃﺮﺡ ﻭ ﺣﺴﺎﺳــﯿﺖ ﮐﺎﺭﺑﺮﺩ ﺍﯾﻦ ﭼﯿﺪﻣﺎﻥ ﺑﺎﯾﺪ ﺍﺯ ﺟﻬﺎﺕ ﻣﺨﺘﻠﻒ ،ﺑﺮﺭﺳﯽ ﺷﻮﻧﺪ. ﺧــﻂ ﻣﮑــﺶ ﺳﺮﻣﺎﯾﺸــﯽ ﺣﺎﻣــﻞ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ﻭ ﺭﻭﻏﻦ ﺭﻭﻏﻦﮐﺎﺭﯼ ﺑﺮﮔﺸــﺘﯽ ﺑﻪ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ﺍﺳﺖ .ﺍﯾﻦ ﺧﻄﻮﻁ ﻣﮑﺸﯽ
ﮐﻨﺪﺍﻧﺴﻮﺭ
ﺧﻂ ﮔﺎﺯ ﮔﺮﻡ
ﺑﺎﯾﺪ ﺑﻪﺩﻗﺖ ﻃﺮﺍﺣﯽ ﻭ ﻧﺼﺐ ﺷــﻮﻧﺪ ﺗﺎ ﺍﺯ ﺟﺮﯾﺎﻥ ﺳﺮﻣﺎﯾﺸﯽ ﮐﺎﻓﯽ
ﺧﻂ ﻣﺎﯾﻊ
ﺩﺍﺧﻞ ﺷﯿﺮ ﺍﻧﺒﺴﺎﻁ
ﮐﻤﭙﺮﺳﻮﺭ
ﺑﺎﺯﮔﺸـﺖ ﻏﯿﺮﺩﻗﯿـﻖ ﺭﻭﻏﻦ :ﺑــﺪﻭﻥ ﺭﻭﻏــﻦ ،ﮐﺎﺭﺍﯾﯽ ﺗﺮﺍﮐﻢ ﮐﺎﻫﺶ ﯾﺎﻓﺘﻪ ﻭ ﻓﺮﺳــﺎﯾﺶ ﺍﻓﺰﺍﯾــﺶ ﻣﯽﯾﺎﺑﺪ .ﻻﯾﻪ ﻧﺎﺯﮐﯽ ﺍﺯ ﺭﻭﻏﻦ
ﺗﺼﻮﯾﺮ ) (2ﭼﯿﻠﺮ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ
ﺑﺮﺍﯼ ﭘﺪﯾﺪ ﺁﻣﺪﻥ ﺁﺏﺑﻨﺪﯼ ﺑﯿﻦ ﺭﻭﺗﻮﺭﻫﺎ ﺑﺮ ﮐﻤﭙﺮﺳــﻮﺭ ﭘﺮﻭﺍﻧﻪﺍﯼ، ﺿﺮﻭﺭﯼ ﺍﺳﺖ .ﺑﺪﻭﻥ ﺭﻭﻏﻦ ،ﮐﺎﺭﺍﯾﯽ ﺗﺮﺍﮐﻢ ﮐﺎﻫﺶ ﻣﯽﯾﺎﺑﺪ .ﻓﻘﺪﺍﻥ ﺭﻭﻏﻦ ﺑﺎﻋﺚ ﻫﺸــﺪﺍﺭ ﮐﺎﻫﺶ ﻓﺸﺎﺭ ﺭﻭﻏﻦ ،ﺧﺎﻣﻮﺷﯽ ﺗﺠﻬﯿﺰﺍﺕ ﻭ ﺩﺭ ﺻﻮﺭﺕ ﻋﺪﻡ ﺗﻮﺟﻪ ،ﻗﻄﻊ ﮐﺎﺭ ﮐﻤﭙﺮﺳﻮﺭ ﺧﻮﺍﻫﺪ ﺷﺪ.
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺧﻂ ﻣﺎﯾﻊ
ﺧﻂ ﮔﺎﺯ ﮔﺮﻡ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻃﺮﺍﺣﯽ ﻭ ﻧﺼﺐ ﻏﯿﺮﺩﻗﯿﻖ ﻟﻮﻟﻪ ﻣﮑﺶ ﻋﺒﺎﺭﺗﻨﺪ ﺍﺯ:
ﺧﻂ ﻣﮑﺶ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻭ ﺭﻭﻏﻦ ﺑﺮﮔﺸــﺘﯽ ﺑﻪ ﮐﻤﭙﺮﺳــﻮﺭ ،ﻣﻄﻤﺌﻦ ﺷــﺪ .ﺑﺮﺧﯽ ﺍﺯ ﻧﺘﺎﯾﺞ
ﺧـﻂ ﻣﮑﺶ ﺑﯿـﺶ ﺍﺯ ﺣﺪ ﮐﻮﭼـﮏ :ﺧﻂ ﻣﮑﺸــﯽ ﺑﯿﺶ ﺍﺯ
ﺑﯿﺮﻭﻥ
ﺣــﺪ ﮐﻮﭼﮏ ،ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﻋﻤﻠﮑﺮﺩ ﭼﯿﻠﺮ ﻭ ﺍﺣﺘﻤﺎﻝ ﺑﺎﺯﮔﺸــﺖ ﮐﻤﭙﺮﺳﻮﺭ
ﺳــﺮﻣﺎﯾﺶ ﺑﻪ ﮐﻤﭙﺮﺳــﻮﺭ ﻣﯽﺷــﻮﺩ .ﺑﺎ ﻫﺮ ﺟﺎﺑﻪﺟﺎﯾﯽ ﻣﺜﺒﺖ ﺩﺭ
ﺧﻂ ﻣﮑﺶ
ﻣﺎﯾﻌﺎﺕ ﻗﺎﺑﻞ ﺗﺮﺍﮐﻢ ﻧﯿﺴــﺘﻨﺪ ،ﺑﺎﻋﺚ ﻧﺎﺭﺳــﺎﯾﯽ ﻓﻮﺭﯼ ﮐﻤﭙﺮﺳﻮﺭ ﺧﻮﺍﻫﺪ ﺷﺪ. ﺧﻂ ﻣﮑﺸـﯽ ﺑﯿﺶ ﺍﺯ ﺣﺪ ﺑﺰﺭﮒ :ﺧﻂ ﻣﮑﺸــﯽ ﺑﯿﺶ ﺍﺯ ﺣﺪ ﺑﺰﺭﮒ ،ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﺳــﺮﻋﺖ ﺳﺮﻣﺎﯾﺸــﯽ ﺩﺭ ﻟﻮﻟﻪﻫﺎ ﻣﯽﺷــﻮﺩ. ﺗﻮﺍﻧﺎﯾﯽ ﻟﻮﻟﻪ ﺑﺮﺍﯼ ﺑﺮﮔﺸــﺖ ﺭﻭﻏﻦ ﺑﻪ ﮐﻤﭙﺮﺳﻮﺭ ،ﺗﺎﺑﻌﯽ ﺍﺯ ﺳﺮﻋﺖ
ﺗﺼﻮﯾﺮ ) (3ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ
ﺗﻠﻔﻦ55401278 :
ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﺳــﺮﻣﺎﯾﺶ ﺍﺳــﺖ .ﺍﮔﺮ ﺳﺮﻋﺖ ﺑﺴــﯿﺎﺭ ﺍﻧﺪﮎ ﺑﺎﺷــﺪ ،ﻧﺘﯿﺠﻪ ﺁﻥ ﺑﺎﺯﮔﺸﺖ ﺿﻌﯿﻒ ﺭﻭﻏﻦ ﺧﻮﺍﻫﺪ ﺑﻮﺩ .ﻓﻘﺪﺍﻥ ﺭﻭﻏﻦ ﺑﺎﻋﺚ ﺻﺪﺍﻫﺎﯾﯽ
ﺩﺭ ﻣﺼــﺮﻑ ﺍﻧــﺮﮊﯼ ﺭﺍ ﭘﺎﯾﯿــﻦ ﺁﻭﺭﺩﻩ ﻭ ﻣﺼﺮﻑ ﺍﻧــﺮﮊﯼ ﺭﺍ ﺍﻓﺰﺍﯾﺶ
ﻫﺸــﺪﺍﺭﺩﻫﻨﺪﻩ ﯾﺎ ﻫﻤﺎﻥﻃﻮﺭ ﮐﻪ ﺩﺭ ﮔﺬﺷﺘﻪ ﻣﻄﺮﺡ ﺷﺪ ،ﻧﺎﺭﺳﺎﯾﯽ
ﻣﯽﺩﻫــﺪ .ﻃﻮﻝ ﺧﻄﻮﻁ ﻣﮑــﺶ ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫــﺎﯼ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ
ﮐﻤﭙﺮﺳﻮﺭ ﻣﯽﺷﻮﺩ.
ﺑﺎﻋﺚ ﺍﺗﻼﻑ ﻇﺮﻓﯿﺖ ﺗﺎ 3%ﺷــﺪﻩ ﮐــﻪ ﺍﻏﻠﺐ ﻣﻨﻄﺒﻖ ﺑﺮ ﺍﻟﺰﺍﻣﺎﺕ
ﺍﺗﻼﻑ ﺩﺭ ﺧﻂ ﻣﮑـﺶ :ﻫﺮﮔﻮﻧﻪ ﺍﺗﻼﻑ ﺩﺭ ﻟﻮﻟﻪ ﻣﮑﺶ ،ﻣﻨﺠﺮ ﺑــﻪ ﺍﺗﻼﻓﯽ ﺩﺭ ﻇﺮﻓﯿﺖ ﭼﯿﻠﺮ ﻣﯽﺷــﻮﺩ .ﮐﺎﻫﺶ ﻇﺮﻓﯿﺖ ،ﮐﺎﺭﺍﯾﯽ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻃﺮﺍﺣﯽ ﻧﯿﺴﺖ. ﺍﻧﺒﺎﺷـﺖﮔﺮ ﻣﮑـﺶ ﺩﺭ ﻣﺤﯿـﻂ :ﺑﺮﺧــﯽ ﺳــﺎﺯﻧﺪﮔﺎﻥ ﭼﯿﻠﺮ ﺍﺯ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ ﻣﺘﻨﺎﻭﺏ ﯾﺎ ﭘﺮﻭﺍﻧﻪﺍﯼ ،ﺑﺎﺯﮔﺸﺖ ﻣﺎﯾﻊ ،ﺍﺯ ﺁﻧﺠﺎ ﮐﻪ
ﺷﯿﺮ ﺍﻧﺒﺴﺎﻁ
ﺻﻔﺤﻪ / 20ﺷﻤﺎﺭﻩ 30
ﻫﻢ ﻭ ﯾﮏﺟﺎ ﺩﺭ ﺩﺍﺧﻞ ﻗﺮﺍﺭ ﮔﺮﻓﺘﻪ ﻭ ﺳﯿﺎﻝ ﺩﺭﻣﻌﺮﺽ ﻫﻮﺍﯼ ﺳﺮﺩ ﺑﯿﺮﻭﻥ ﻧﯿﺴــﺖ .ﺍﺟﺰﺍﯼ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻭ ﮐﻤﭙﺮﺳــﻮﺭ ﺑﻪ ﺧﻄﻮﻁ ﻣﺎﯾﻊ ﻭ ﺧﻂ ﻣﺎﯾﻊ
ﮔﺎﺯ ﮔﺮﻣﯽ ﮐﻪ ﺑﻪ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺴﺘﻘﺮ ﺩﺭ ﺑﯿﺮﻭﻥ ﻣﯽﺭﺳﻨﺪ،
ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﻣﺘﺼﻞ ﻣﯽﺷــﻮﻧﺪ .ﺍﯾﻦ ﭼﯿﺪﻣﺎﻥ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ ) (5ﻧﺸــﺎﻥ ﺩﺍﺩﻩ ﺧﻂ ﻣﮑﺶ
ﺷــﺪﻩ ﺍﺳﺖ ،ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺿﺪﯾﺦ ﺭﺍ ﮐﺎﻫﺶ ﺩﺍﺩﻩ ﻭ ﻣﺰﺍﯾﺎﯼ ﺩﯾﮕﺮﯼ ﻧﯿﺰ ﺩﺍﺭﺩ.
ﭼﯿﻠﺮ
ﺩﺭﻧﺘﯿﺠﻪ ﻗﺮﺍﺭ ﮔﺮﻓﺘﻦ ﮐﻤﭙﺮﺳﻮﺭ ﻭ ﺍﭘﺮﺍﺗﻮﺭ ﺩﺭ ﺩﺍﺧﻞ ،ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ﺑﺪﻭﻥ ﻃﺮﺍﺣﯽ ﻣﺤﯿﻄﯽ ﻭ ﻧﺼﺐ ﺧﻄﻮﻁ ﻣﮑﺶ، ﻓﺮﺍﻫــﻢ ﻣﯽﺁﯾﺪ .ﭼﯿﻠﺮﻫــﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺍﺯ ﺧﻄﻮﻁ ﻣﺎﯾﻊ ﻭ
ﺗﺼﻮﯾﺮ ) (4ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﻣﻌﻤﻮﻝ ﺑﺎ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﺍﻧﺒﺎﺷــﺖﮔﺮﻫﺎﯼ ﻣﮑﺶ ﻧﺼﺐﺷــﺪﻩ ﺩﺭ ﻣﺤﯿﻂ ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ .ﺍﯾﻦ ﺗﺠﻬﯿﺰﺍﺕ ﮐﻪ ﻣﻤﮑﻦ ﺍﺳــﺖ ﺻﺪﻫﺎ ﻓﻮﺕ ﻃﻮﻝ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻨﺪ ،ﺑﺮﺍﯼ ﺍﻓﺰﺍﯾﺶ ﺣﺠﻢ ﺫﺧﯿﺮﻩ ﻟﻮﻟﻪ ﻣﮑﺶ ،ﺿﺮﻭﺭﯼ ﺗﻠﻘﯽ ﻣﯽﺷﻮﻧﺪ .ﺍﯾﻦ ﺍﻣﺮ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺑﺮﺍﯼ ﺑﻘﺎﯼ ﺳﺮﻣﺎﯾﺶ ﺩﺭ ﺧﻂ ﻣﮑﺶ ،ﺩﺭﻃﻮﻝ ﺧﺎﻣﻮﺷﯽ ﭼﺮﺧﻪ ،ﻻﺯﻡ ﺍﺳــﺖ .ﺍﮔﺮ ﺍﻧﺒﺎﺷــﺖﮔﺮ ﮐﻮﭼﮏﺗﺮ ﺍﺯ ﺣﺪ ﻻﺯﻡ ﺑﺎﺷﺪ ﯾﺎ ﺑﻪ ﻓﺮﺍﻣﻮﺷﯽ ﺳﭙﺮﺩﻩ ﺷﻮﺩ ،ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﻪ ﮐﻤﭙﺮﺳﻮﺭ ﻭﺍﺭﺩ ﺷﺪﻩ ﻭ ﺑﺎﻋﺚ ﻧﺎﺭﺳﺎﯾﯽ ﻓﺎﺟﻌﻪﺁﻣﯿﺰﯼ ﺩﺭ ﮐﻤﭙﺮﺳﻮﺭ ﻣﯽﺷﻮﻧﺪ. ﮐﺎﺭﺑــﺮﺩ ﺍﻭﺍﭘﺮﺍﺗــﻮﺭ ﻣﺠﺰﺍ ﺑﻪ ﻣﯿــﺰﺍﻥ ﺯﯾﺎﺩﯼ ﺑﺴــﺘﮕﯽ ﺑﻪ ﺗﺠﺮﺑﻪ ﻣﻘﺎﻃﻌﻪﮐﺎﺭ ﻫﻤﺮﺍﻩ ﺑﺎ ﻣﻬﻨﺪﺳــﯽ ﺩﻗﯿﻖ ﺍﻧﺒﺎﺷــﺖﮔﺮﻫﺎ ﻭ ﻟﻮﻟﻪﮐﺸﯽ ﺳﺮﻣﺎﯾﺸــﯽ ﺩﺍﺭﺩ .ﺍﮔﺮ ﻣﻬﻨﺪﺳﯽ ﺑﻪﺧﻮﺑﯽ ﺻﻮﺭﺕ ﻧﮕﺮﻓﺘﻪ ﻭ ﻧﺼﺐ ﺑﺎ ﺩﻗــﺖ ﺍﻧﺠﺎﻡ ﻧﺸــﻮﺩ ،ﻧﺘﯿﺠﻪ ﺁﻥ ﺍﺗﻼﻑ ﺍﻧﺮﮊﯼ ﻭ ﺑﺪﺗﺮ ،ﻧﺎﺭﺳــﺎﯾﯽ ﺩﺭ ﺗﺠﻬﯿﺰﺍﺕ ﺧﻮﺍﻫﺪ ﺑﻮﺩ .ﻣﺴﻮﻭﻟﯿﺖ ﻃﺮﺍﺣﯽ ﺩﻗﯿﻖ ﺑﺎ ﻣﻬﻨﺪﺱ ﻣﺸﺎﻭﺭ
ﺁﺏ ﮔﺮﻣﯽ ﺑﻬــﺮﻩ ﻣﯽﺑﺮﻧﺪ ﮐﻪ ﺍﻧﺪﺍﺯﻩ ﺁﻥﻫﺎ ﺩﺭ ﺟﺪﻭﻝﻫﺎﯾﯽ ﺍﺳــﺖ ﮐﻪ ﺳــﺎﺯﻧﺪﻩ ﺍﺭﺍﺋﻪ ﻣﯽﺩﻫﺪ .ﺑﺎ ﺍﯾﻦ ﻋﻤــﻞ ،ﺗﻐﯿﯿﺮﺍﺕ ﭘﺪﯾﺪﺁﻣﺪﻩ ﺩﺭ ﺍﺛــﺮ ﻧﺼﺐ ﺧﻂ ﻣﮑﺶ ﻭ ﺍﻧﺪﺍﺯﻩ ﺍﻧﺒﺎﺷــﺖﮔﺮ ﻣﮑﺶ ،ﮐﺎﻣﻼ ﺣﺬﻑ ﻣﯽﺷﻮﻧﺪ .ﻫﻤﺮﺍﻩ ﺑﺎ ﭼﯿﻠﺮﻫﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ،ﺗﻤﺎﻡ ﺧﻂ ﻣﮑﺶ ﺑﻪ ﻭﺳﯿﻠﻪ ﮐﺎﺭﺧﺎﻧﻪ ﻃﺮﺍﺣﯽ ﻭ ﺑﺎ ﻓﺮﺁﯾﻨﺪﯼ ﮐﺎﻣﻼ ﮐﻨﺘﺮﻝﺷﺪﻩ ،ﻧﺼﺐ ﻣﯽﺷــﻮﺩ .ﺍﯾﻦ ﭼﯿﺪﻣﺎﻥ ،ﻣﺴــﺎﯾﻞ ﻣﻄﺮﺡ ﺩﺭ ﻃﺮﺍﺣﯽ ﻣﺤﯿﻄﯽ ﻭ ﻧﺼــﺐ ﺧﻄﻮﻁ ﻣﮑﺶ ﺭﺍ ﺑﻪ ﺣﺪﺍﻗﻞ ﻣﯽﺭﺳــﺎﻧﺪ ﮐﻪ ﺑﺮﺍﯼ ﻋﻤﻠﮑﺮﺩ ﮐﺎﺭﺍ ﻭ ﻣﻄﻤﺌﻦ ﭼﯿﻠﺮ ﺣﯿﺎﺗﯽ ﻫﺴﺘﻨﺪ. ﻫﻤﭽﻨﯿﻦ ﻗﺮﺍﺭ ﮔﺮﻓﺘﻦ ﮐﻤﭙﺮﺳﻮﺭ ﻭ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺩﺭ ﺩﺍﺧﻞ ،ﺑﺎﻋﺚ ﺩﺳﺘﺮﺳــﯽ ﺁﺳــﺎﻥﺗﺮ ﺑﻪ ﺍﺟﺰﺍﯼ ﺣﯿﺎﺗﯽ ﭼﯿﻠﺮ ﺑﻪﻣﻨﻈــﻮﺭ ﺗﻌﻤﯿﺮ ﻭ ﻧﮕﻬﺪﺍﺭﯼ ﻣﯽﺷﻮﺩ.
ﮐﺎﻫﺶ ﺳﺮﻭﺻﺪﺍ ﮐﻨﺪﺍﻧﺴــﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ﺩﺭ ﻣﻘﺎﯾﺴﻪ ﺑﺎ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ، ﺳﻄﺢ ﺻﻮﺗﯽ ﭘﺎﯾﯿﻦ ﺗﺮﯼ ﺩﺍﺭﻧﺪ. ﻣﻘﺎﯾﺴــﻪ ﻓﺸــﺎﺭ ﺻﻮﺗﯽ ﺑﯿﺮﻭﻥ ﺑﺮﺍﯼ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ
ﻭ ﻣﺴﻮﻭﻟﯿﺖ ﻧﺼﺐ ﺑﺮ ﻋﻬﺪﻩ ﻣﻘﺎﻃﻌﻪﮐﺎﺭ ﺍﺳﺖ.
ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺑﺎ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ،ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯾﯽ ﺩﺭ ﺑﯿﺮﻭﻥ ﺩﺍﺭﺩ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ ) (4ﻧﺸــﺎﻥ ﺩﺍﺩﻩ ﺷﺪ .ﺍﯾﻦ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ﺳﺮﻭﺻﺪﺍ ﺭﺍ ﺩﺭ ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﭼﯿﻠﺮﻫﺎﯼ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﻭ ﺳﺮﻭﺻﺪﺍ
ﻣﺤﯿﻂ ﻣﻨﺘﺸﺮ ﻣﯽﮐﻨﻨﺪ .ﮐﻠﯿﺴﺎﻫﺎ ،ﻧﻮﺍﺣﯽ ﻣﺴﮑﻮﻧﯽ ،ﺁﭘﺎﺭﺗﻤﺎﻥﻫﺎ ﻭ
ﺑﯿﺮﻭﻥ
ﻣﺪﺭﺳﻪﻫﺎ ﮐﻪ ﺍﺯ ﻓﻮﺍﺻﻞ ﺩﻭﺭ ﺻﺪﺍﯼ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺭﺍ ﻣﯽﺷﻨﻮﻧﺪ ،ﻫﻤﻪ ﺩﺭﻣﻌﺮﺽ ﺳﻄﻮﺣﯽ ﺍﺯ ﺳﺮﻭﺻﺪﺍ ﻫﺴﺘﻨﺪ .ﺳﻄﺢ ﺻﺪﺍﯼ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ
ﻣﺎﯾﻊ
ﻣﯽﺗﻮﺍﻧﺪ ﺗﺎ 20ﺩﺳﯽﺑﻞ ﺑﺎﺷﺪ ﮐﻪ ﺑﯿﺶ ﺍﺯ ﺳﻄﺢ ﺻﺪﺍﯼ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ
ﮔﺎﺯ ﮔﺮﻡ
ﺩﺭﻭﻥ ﮔﺎﺯ ﮔﺮﻡ ﻣﺎﯾﻊ
ﻣﺠﺰﺍ ﺑﻮﺩﻩ ﻭ ﺑﺎﻋﺚ ﺗﻔﺎﻭﺕ ﻗﺎﺑﻞ ﻣﻼﺣﻈﻪﺍﯼ ﺩﺭ ﺁﺳﺎﯾﺶ ﻣﯽﺷﻮﺩ.
ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ،ﺑﻬﺘﺮﯾﻦ ﺭﺍﻩﺣﻞ ﺑﺮﺍﯼ ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ﻭ ﮐﺎﻫﺶ ﺳﺮﻭﺻﺪﺍ ﻣﺰﺍﯾﺎﯼ ﻗﺮﺍﺭﮔﺮﻓﺘﻦ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ﻭ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺩﺭ ﺩﺍﺧﻞ ﺩﺭ ﭼﯿﻠﺮﻫﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ،ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻭ ﮐﻨﺪﺍﻧﺴــﻮﺭﻫﺎ ﺑﺎ ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺗﺼﻮﯾﺮ ) (5ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻣﻌﻤﻮﻝ ﺑﺎ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 21ﺷﻤﺎﺭﻩ 30
ﺟﺎﯼ ﺑﺴﯿﺎﺭ ﮐﻤﺘﺮﯼ ﺍﺷﻐﺎﻝ ﻣﯽﮐﻨﺪ :ﺑﺮﺧﯽ ﺑﺴﺘﻪﻫﺎﯼ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﻣﻘﺎﯾﺴﻪ ﻓﺸﺎﺭ ﺻﻮﺗﯽ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺩﺭﺑﺮﺍﺑﺮ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ﻓﺸﺎﺭ ﺻﻮﺗﯽ )ﺩﺳﯽﺑﻞ (A -ﺩﺭ 30ﻓﻮﺗﯽ ﻣﻨﺒﻊ
ﻇﺮﻓﯿﺖ )ﺗﻦ( ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ
ﻣﺠﺰﺍ 25ﺗﻦ 60 ،ﺍﯾﻨﭻ ﭘﻬﻨﺎ ﺩﺍﺭﻧﺪ .ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﮐﺮﯾﺮ 270ﺗﻦ ،ﻣﻨﺎﺳﺐ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 36ﺍﯾﻨﭽﯽ ﺭﺍﻫﺮﻭ ﺍﺳﺖ. ﮐﺎﻫﺶ ﺑﺎﺭ ﺑﺮ ﺳـﻘﻒ :ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﮐﻪ ﺑﺎ ﭼﯿﻠﺮﻫﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﻧﺪ ،ﺩﺭ ﻣﻘﺎﯾﺴــﻪ ﺑﺎ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻫﻤﺮﺍﻩ ﺑﺎ ﮐﻤﭙﺮﺳﻮﺭﻫﺎ ،ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎ ﻭ ﺍﻭﺍﭘﺮﺍﺗﻮﺭﻫﺎﯼ ﭘﺮﺷﺪﻩ ﺑﺎ ﺳــﯿﺎﻝ ،ﺳــﺒﮏﺗﺮﻧﺪ .ﺑﺮﺧﯽ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ 250ﺗﻦ ،ﻭﺯﻧﯽ ﺗــﺎ 18500ﭘﻮﻧﺪ ﺩﺍﺭﻧــﺪ ،ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﺩﻭ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ ﺩﺭ ﺳﯿﺴﺘﻤﯽ 250ﺗﻦ ،ﻭﺯﻧﯽ ﮐﻤﺘﺮ ﺍﺯ 6100ﭘﻮﻧﺪ ﺧﻮﺍﻫﻨﺪ ﺩﺍﺷﺖ ﮐﻪ ﮐﻤﺘﺮ ﺍﺯ ﻧﺼﻒ ﺁﻥ ﻭﺯﻥ ﺍﺳﺖ .ﺑﺎ ﻗﺮﺍﺭﮔﺮﻓﺘﻦ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ
ﺩﺭ ﺩﺍﺧﻞ ﻭ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﺩﺭ ﺑﯿﺮﻭﻥ ،ﻫﺰﯾﻨﻪﻫﺎﯼ ﺍﺳﺘﻔﺎﺩﻩ
ﺗﺼﻮﯾﺮ ) (6ﻓﺸﺎﺭ ﺻﻮﺗﯽ )ﺩﺳﯽﺑﻞ (A -ﺑﺮﺍﯼ ﭼﯿﻠﺮﻫﺎﯼ ﻣﺎﺭﭘﯿﭻ ﻫﻮﺍﯾﯽ ﺩﺭﺑﺮﺍﺑﺮ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ
ﺍﺯ ﻓﻮﻻﺩ ﺳﺎﺧﺘﺎﺭﯼ ﻭ ﺗﺠﻬﯿﺰﺍﺕ ﻧﮕﻬﺪﺍﺭﻧﺪﻩ ،ﮐﺎﻫﺶ ﻣﯽﯾﺎﺑﺪ. ﮐﻨﺪﺍﻧﺴــﻮﺭﻫﺎﯼ ﻫﻮﺍﯾــﯽ ،ﺳــﻄﺢ ﻣﻘﻄﻊ ﭘﺎﯾﯿﻦﺗــﺮﯼ ﺩﺍﺭﻧﺪ. ﺁﺭﺷﯿﺘﮑﺖﻫﺎ ﺗﺮﺟﯿﺢ ﻣﯽﺩﻫﻨﺪ ﺍﺯ ﺗﺠﻬﯿﺰﺍﺕ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺑﯿﺮﻭﻧﯽ ﺑﺎ ﺳــﻄﺢ ﻣﻘﻄﻊ ﻋﻤﻮﺩﯼ ﭘﺎﯾﯿﻨﯽ ﺍﺳــﺘﻔﺎﺩﻩ ﮐﻨﻨﺪ ﺗﺎ ﺩﯾﺪ ﺑﻪ ﺁﻥﻫﺎ
ﭘﺮﺳﺮﻭﺻﺪﺍﺗﺮ ﺍﺯ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ﻫﺴﺘﻨﺪ.
ﺳﯿﺴــﺘﻢ 250ﺗﻦ ،ﺗﻨﻬﺎ 42ﺍﯾﻨﭻ ﺍﺭﺗﻔﺎﻉ ﺩﺍﺭﻧﺪ ﮐﻪ ﮐﻤﺘﺮ ﺍﺯ ﻧﺼﻒ
ﭼﮕﻮﻧﻪ ﻣﯽﺗﻮﺍﻥ ﺑﺎ ﺍﯾﻦ ﻓﺸﺎﺭ ﺻﻮﺗﯽ ﻣﻘﺎﺑﻠﻪ ﮐﺮﺩ؟ ﺟﺪﻭﻝ )(A ﻧﺸﺎﻥﺩﻫﻨﺪﻩ ﺗﺎﺛﯿﺮ ﺗﻐﯿﯿﺮ ﺷﻨﻮﺍﯾﯽ ﺩﺭ ﺳﻄﻮﺣﯽ ﺑﺎ ﻓﺮﮐﺎﻧﺲﻫﺎﯼ ﺑﺎﻻ
ﺳﻄﺢ ﻣﻘﻄﻊ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺑﻮﺩﻩ ﻭ ﭘﻨﻬﺎﻥ ﺷﺪﻥ ﺁﻥ ﺍﺯ ﺩﯾﺪ ،ﺁﺳﺎﻥﺗﺮ ﺍﺳﺖ.
ﻭ ﭘﺎﯾﯿﻦ ﺍﺳﺖ .ﺑﺎ 20ﺩﺳﯽﺑﻞ ﺍﺧﺘﻼﻑ ﺩﺭ ﻓﺸﺎﺭ ﺻﻮﺗﯽ ،ﭼﯿﻠﺮﻫﺎﯼ
ﺍﻓﺰﺍﯾﺶ ﺳﻄﺢ ﺗﺮﺍﮐﻢ ﺍﺯ ﺧﻄﻮﻁ ﮔﺎﺯ ﮔﺮﻡ :ﻫﺪﻑ ﺍﺯ ﮐﻨﺪﺍﻧﺴﻮﺭ
ﻫﻮﺍﯾﯽ ﻣﻄﻤﺌﻨﺎ ﺑﺴﯿﺎﺭ ﭘﺮﺳﺮﻭﺻﺪﺍﺗﺮ ﺍﺯ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ
ﻫﻮﺍﯾﯽ ،ﮐﺎﻫﺶ ﺩﻣﺎﯼ ﺑﺎﻻﯼ ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﻪ ﻣﺎﯾﻊ ﺍﺳﺖ .ﺧﻂ
ﺑﺎ ﻇﺮﻓﯿﺘﯽ ﻣﺸﺎﺑﻪ ﺩﺭ ﺳﯿﺴﺘﻢ ﺁﺏ ﺳﺮﺩ ﺧﻮﺍﻫﻨﺪ ﺑﻮﺩ.
ﮔﺎﺯ ﮔﺮﻡ ،ﻋﻤﻼ ﺑﻪ ﻭﺳﯿﻠﻪ ﺧﻨﮏ ﺷﺪﻥ ﮔﺎﺯ ﮔﺮﻡ ﻭﺍﺭﺩ ﻓﺮﺁﯾﻨﺪ ﺗﺮﺍﮐﻢ ﺷــﺪﻩ ﻭ ﭘﯿﺶ ﺍﺯ ﺳﺮﻣﺎﯾﺶ ،ﻭﺍﺭﺩ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻣﯽﺷﻮﺩ .ﺧﻂ ﮔﺎﺯ
ﻣﺰﺍﯾﺎﯼ ﺩﯾﮕﺮ ﭼﯿﻠﺮﻫﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺳﻄﻮﺡ ﺻﻮﺗﯽ ﺍﺳﺖ )ﺗﺼﻮﯾﺮ .(6ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ ﺗﺎ 20ﺩﺳﯽﺑﻞ
ﻣﯽﺭﺳــﻨﺪ ،ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﮐﻨﺪﺍﻧﺴــﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ﺩﺭ ﻫﻤﺎﻥ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺩﺭﺑﺮﺍﺑﺮ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ،ﻧﺸــﺎﻥﺩﻫﻨﺪﻩ ﺍﻓﺰﺍﯾﺶ ﻗﺎﺑﻞ ﻣﻼﺣﻈﻪﺍﯼ ﺩﺭ
ﺁﺳــﺎﻥﺗﺮ ﺑﺎﺷــﺪ .ﺑﺮﺧﯽ ﭼﯿﻠﺮﻫﺎﯼ ﻫﻮﺍﯾﯽ 250ﺗــﻦ ﺑﻪ 95ﺍﯾﻨﭻ
ﮔﺮﻡ ﺑﻪ ﺍﯾﻦ ﻓﺮﺁﯾﻨﺪ ﺧﻨﮏ ﺷــﺪﻥ ﺑﺎ ﺍﻓﺰﻭﺩﻥ ﮐﺎﺭﺍﯾﯽ ﺳــﻄﺤﯽ ﺑﻪ
ﻗﺮﺍﺭﮔﺮﻓﺘﻦ ﮐﻤﭙﺮﺳــﻮﺭ ﻭ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﺩﺭ ﺩﺍﺧــﻞ ،ﻣﺰﺍﯾﺎﯾﯽ ﻭﺭﺍﯼ
ﮐﻨﺪﺍﻧﺴﻮﺭ ،ﻣﯽﺭﺳﺪ.
ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ﻭ ﮐﺎﻫﺶ ﺳﺮﻭﺻﺪﺍ ﺩﺍﺭﺩ. ﺩﯾﮕﺮ ﻣﺰﺍﯾﺎﯼ ﺁﻥ ﻋﺒﺎﺭﺗﻨﺪ ﺍﺯ: ﮐﻤﭙﺮﺳﻮﺭ ﺩﺭ ﻣﻘﺎﯾﺴــﻪ ﺑﺎ ﺗﺠﻬﯿﺰﺍﺕ ﭼﯿﻠﺮﯼ ﮐﻪ ﺩﺭ ﺑﯿﺮﻭﻥ ﯾﺎ ﺭﻭﯼ ﺳﻘﻒ ﻗﺮﺍﺭ ﮔﯿﺮﺩ ،ﺳﺎﺩﻩﺗﺮ ﺍﺳﺖ .ﺗﮑﻨﺴﯿﻦﻫﺎ ﻣﯽﺗﻮﺍﻧﻨﺪ ﻣﺴﺘﻘﯿﻤﺎ ﺑﻪ ﺳﻤﺖ ﮐﻤﭙﺮﺳﻮﺭ ﻣﺴﺘﻘﺮ ﺩﺭ ﻣﺤﻞ ﺭﻓﺘﻪ ﻭ ﺑﻪ ﺁﺳﺎﻧﯽ ﺑﻪ ﺗﺠﻬﯿﺰﺍﺕ ﻣﻬﻢ ﭼﯿﻠﺮ ﺩﺳﺖ ﯾﺎﺑﻨﺪ. ﻧﯿﺎﺯﯼ ﺑﻪ ﺳـﯿﺎﻻﺕ ﺿﺪﯾﺦ ﻭﺟﻮﺩ ﻧـﺪﺍﺭﺩ :ﺑﺮﺧﯽ ﺣﻼﻝﻫﺎﯼ
ﻓﺮﮐﺎﻧﺲﻫﺎﯼ ﺑﺎﻻ )ﺑﯿﺶ ﺍﺯ 125ﻫﺮﺗﺰ ﺑﺎﻧﺪ ﺍﮐﺘﺎﻭ( ﻗﺎﺑﻞ ﺗﻮﺟﻪ ﻧﯿﺴﺖ ﻗﺎﺑﻞ ﺩﺭﮎ ﻗﺎﺑﻞ ﺗﻮﺟﻪ ﺩﻭﺑﺮﺍﺑﺮ
ﺿﺪﯾــﺦ ،ﻣﺸــﮑﻼﺗﯽ ﭘﺪﯾﺪ ﻣﯽﺁﻭﺭﻧﺪ ﮐﻪ ﺑﺎ ﺍﯾــﻦ ﺭﻭﺵ ﻣﯽﺗﻮﺍﻥ ﺍﺯ
ﺑﺴﯿﺎﺭ ﺑﻠﻨﺪ ﻓﺮﮐﺎﻧﺲﻫﺎﯼ ﭘﺎﯾﯿﻦ ) 125ﻫﺮﺗﺰ ﻭ ﮐﻤﺘﺮ ﺍﺯ ﺁﻥ ﺑﺎﻧﺪ ﺍﮐﺘﺎﻭ( ﻗﺎﺑﻞ ﺗﻮﺟﻪ
ﻭﯾﺴــﮑﻮﺯﯾﺘﻪ ﺑﺎﻻﺗﺮ ﻭ ﺍﻧﺘﻘﺎﻝ ﺣﺮﺍﺭﺗــﯽ ﻧﺎﮐﺎﺭﺁﻣﺪ ﺣﻼﻝﻫﺎﯼ ﺿﺪﯾﺦ
ﺩﻭﺑﺮﺍﺑﺮ
ﺭﺍ ﺑﺮﻃﺮﻑ ﻣﯽﮐﻨﺪ.
ﺑﺴﯿﺎﺭ ﺑﻠﻨﺪ
ﺁﻥﻫــﺎ ﺍﺟﺘﻨﺎﺏ ﮐــﺮﺩ .ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺁﺏ ،ﺍﺗﻼﻑ ﺍﻧﺮﮊﯼ ﻧﺎﺷــﯽ ﺍﺯ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﻠﻔﻦ55401278 :
ﺗﻌﻤﯿـﺮ ﻭ ﻧﮕﻬﺪﺍﺭﯼ ﺁﺳـﺎﻥﺗﺮ :ﺩﺭ ﺍﯾﻦ ﺣﺎﻟﺖ ،ﺩﺳﺘﺮﺳــﯽ ﺑﻪ
ﺗﺎﺛﯿﺮ ﺑﺮ ﺷﻨﻮﺍﯾﯽ
ﺍﻓﺰﺍﯾﺶ ﻓﺸﺎﺭ ﺻﻮﺗﯽ )ﺩﺳﯽﺑﻞ(
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺟﺪﻭﻝ ) (Aﺗﺎﺛﯿﺮ ﻓﺮﮐﺎﻧﺲﻫﺎﯼ ﺑﺎﻻ ﻭ ﭘﺎﯾﯿﻦ ﺑﺮ ﺷﻨﻮﺍﯾﯽ
ﺻﻔﺤﻪ / 22ﺷﻤﺎﺭﻩ 30
ﺟﺪﻭﻝ ) (Bﺗﺎﺛﯿﺮ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ 40%ﻣﺤﻠــﻮﻝ ﺿﺪﯾﺦ ﭘﺮﻭﭘﯿﻠﻦ ﮔﻠﯿﮑﻮﻝ ﺑﺮ ﻋﻤﻠﮑﺮﺩ ﭼﯿﻠﺮ ﻫﻮﺍ ﺧﻨﮏ 40%ﻣﺤﻠﻮﻝ ﺗﻔﺎﻭﺕ ﺑﺮﺣﺴﺐ ﺿﺪﯾﺦ ﭘﺮﻭﭘﯿﻠﻦ ﺩﺭﺻﺪ ﮔﻠﯿﮑﻮﻝ
ﺳﺮﺩ ﮐﻪ ﻣﯽﺗﻮﺍﻧﺪ ﺩﺭﻣﻌﺮﺽ ﻫﻮﺍﯼ ﺳﺮﺩ ﺑﯿﺮﻭﻥ ﻗﺮﺍﺭ ﮔﯿﺮﺩ ،ﺍﺳﺘﻔﺎﺩﻩ ﺷــﻮﺩ .ﺑﺮﺍﯼ ﻣﺤﺎﻓﻈﺖ ﮐﻮﯾﻞﻫﺎﯼ ﺁﺏ ﺳﺮﺩ ﻧﯿﺰ ﮐﻪ ﺩﺭﻣﻌﺮﺽ ﻫﻮﺍﯼ ﺳﺮﺩ ﻭﺭﻭﺩﯼ ﻫﺴﺘﻨﺪ ،ﯾﺎ ﮐﻮﯾﻞﻫﺎﯾﯽ ﮐﻪ ﺩﺭ ﺑﯿﺮﻭﻥ ﻭ ﺩﺭ ﺷﺮﺍﯾﻄﯽ ﮐﻪ
ﺁﺏ ﺗﺎﺯﻩ ﻇﺮﻓﯿﺖ ﺗﻮﺍﻥ ﮐﻞ ﮐﺎﺭﺍﯾﯽ ﻭﺯﻥ ﻋﻤﻠﯿﺎﺗﯽ ﺣﺪﺍﻗﻞ ﺁﻣﭙﺮ ﺩﺭ ﻣﺪﺍﺭ ﻃﻮﻝ ﻋﺮﺽ ﺍﺭﺗﻔﺎﻉ ﺍﻓﺖ ﻓﺸﺎﺭ ﺧﻨﮏﺗﺮ ﻣﻮﺗﻮﺭ ﭘﻤﭗ ﺗﻮﺍﻥ ﭘﺮﻭﭘﯿﻠﻦ ﮔﻠﯿﮑﻮﻝ ﭘﻤﭗ
ﺩﺭﻣﻌﺮﺽ ﻫﻮﺍﯼ ﺳﺮﺩﻧﺪ ،ﻧﺼﺐ ﻣﯽﺷﻮﻧﺪ ﺑﺎﯾﺪ ﺍﺯ ﺿﺪﯾﺦ ﺑﻬﺮﻩ ﺑﺮﺩ. ﻣﯽ ﺗﻮﺍﻥ ﺑﺎ ﮐﺎﻫﺶ ﻭﯾﺴــﮑﻮﺯﯾﺘﻪ ﺳﯿﺎﻝ ﻭ ﺑﻬﺒﻮﺩ ﺿﺮﯾﺐ ﺍﻧﺘﻘﺎﻝ ﺣﺮﺍﺭﺗــﯽ ﮐﻪ ﺗﺤﺖ ﺗﺎﺛﯿﺮ ﻣﺤﻠﻮﻝﻫﺎﯼ ﺿﺪﯾﺦ ﻫﺴــﺘﻨﺪ ،ﺩﺭ ﻣﺼﺮﻑ ﺍﻧــﺮﮊﯼ ﺻﺮﻓﻪﺟﻮﯾﯽ ﮐﺮﺩ .ﮐﺎﻫﺶ ﻭﯾﺴــﮑﻮﺯﯾﺘﻪ ،ﺍﻧــﺮﮊﯼ ﻻﺯﻡ ﺑﺮﺍﯼ ﭘﻤﭙﺎﮊ ﺁﺏ ﺳــﺮﺩ ﺭﺍ ﮐﺎﺳﺘﻪ ﻭ ﺑﻬﺒﻮﺩ ﺍﻧﺘﻘﺎﻝ ﺣﺮﺍﺭﺗﯽ ،ﮐﺎﺭﺍﯾﯽ ﭼﯿﻠﺮ ﺭﺍ ﺍﻓﺰﺍﯾﺶ ﻣﯽﺩﻫﺪ .ﻫﺮ ﺩﻭ ﺍﯾﻦ ﻋﻮﺍﻣﻞ ،ﻭﻗﺘﯽ ﺍﻧﺮﮊﯼ ﺳﯿﺴﺘﻢ ﻣﻼﺣﻈﻪ ﻣﯽﺷﻮﺩ ،ﻧﺘﺎﯾﺞ ﺩﻟﺨﻮﺍﻫﯽ ﻫﻤﺮﺍﻩ ﺧﻮﺍﻫﻨﺪ ﺩﺍﺷﺖ. ﺳﻤﯽ ﺑﻮﺩﻥ ﺍﺗﯿﻠﻦﮔﻠﯿﮑﻮﻝ ،ﻣﻨﺠﺮ ﺑﻪ ﺍﻧﺘﺨﺎﺏ ﺣﻼﻝﻫﺎﯾﯽ ﺑﺎ ﺳﻢ ﮐﻤﺘﺮ ﻣﺎﻧﻨﺪ ﭘﺮﻭﭘﯿﻠﻦﮔﻠﯿﮑﻮﻝ ﻣﯽﺷﻮﺩ .ﺑﯿﺸﺘﺮ ﻃﺮﺍﺣﺎﻥ ﺍﺯ ﻣﺤﻠﻮﻝﻫﺎﯼ
ﻣﺠﻤﻮﻉ ﻫﺰﯾﻨﻪ ﺳﺎﻟﯿﺎﻧﻪ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻣﺪﻝ HXA 30ﺩﺭﺑﺮﺍﺑﺮ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ،ﺳﯿﺴﺘﻢﻫﺎﯼ ﺳﺎﺧﺘﻤﺎﻧﯽ ﻭ ﺗﻌﻤﯿﺮﺍﺕ ﮐﺮﯾﺮ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺟﺪﻭﻝ ) (1ﻫﺰﯾﻨﻪﻫﺎﯼ ﺳﺎﻟﯿﺎﻧﻪ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎ ﺁﺏ ﺗﺎﺯﻩ
ﺿﺪﯾﺨﯽ ﺑﺎ ﻏﻠﻈﺖ ﺗﺎ 40%ﺑﺮﺍﯼ ﺳﯿﺴﺘﻢﻫﺎﯾﯽ ﺩﺭ ﺁﺏﻭﻫﻮﺍﯼ ﺳﺮﺩ، ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ .ﻏﻠﻈﺖ ﺑﯿﺸﺘﺮ ﺑﺎﻋﺚ ﺍﻓﺰﺍﯾﺶ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺑﻪ ﺩﻟﯿﻞ ﻭﯾﺴﮑﻮﺯﯾﺘﻪ ﻭ ﺍﺗﻼﻑ ﺍﻧﺘﻘﺎﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯽﺷﻮﺩ.
ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺑﺎ ﻣﺤﻠﻮﻝ 40%ﺿﺪﯾﺦ
ﺟــﺪﻭﻝ ) (Bﻧﺸــﺎﻥﺩﻫﻨﺪﻩ ﺗﺎﺛﯿــﺮ ﺍﻓــﺰﻭﺩﻥ 40%ﻣﺤﻠــﻮﻝ
ﺑﺨﺶ
ﭘﺮﻭﭘﯿﻠﻦﮔﻠﯿﮑﻮﻝ ﺑﻪ ﭼﯿﻠﺮﯼ 250ﺗﻦ ﺩﺭ ﺩﻣﺎﻫﺎﯼ ﺣﺪ ﭘﺎﯾﯿﻦ ﻭ ﺑﺎﻻﯼ ﻓﻦﻫﺎﯼ ﺳﯿﺴﺘﻢ ﻫﻮﺍ ﺳﺮﻣﺎﯾﺶ ﮔﺮﻣﺎﯾﺶ ﭘﻤﭗﻫﺎ ﻣﺠﻤﻮﻉ ﭘﻤﭗﻫﺎ ﻭ ﺳﺮﻣﺎﯾﺶ ﻣﺠﻤﻮﻉ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ
ﺗﺼﻮﯾﺮ ) (7ﻫﺰﯾﻨﻪ ﺳﺎﻟﯿﺎﻧﻪ ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺑﺎ ﻣﺤﻠﻮﻝ 40%ﺿﺪﯾﺦ ﺩﺭﺑﺮﺍﺑﺮ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎ ﺁﺏ ﺗﺎﺯﻩ
54 / 45ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﻭ 95ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺩﻣﺎﯼ ﻫﻮﺍﯼ ﻣﺤﯿﻂ، ﺍﺳــﺖ .ﺗﻮﺟﻪ ﺷــﻮﺩ ﺑﺮﺍﯼ ﺗﺎﻣﯿﻦ ﻇﺮﻓﯿﺖ ﻣﻮﺭﺩ ﻧﻈﺮ ،ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻣﺤﻠﻮﻝ ﺿﺪﯾﺦ ،ﺑﺎﯾﺪ ﺍﺯ ﭼﯿﻠﺮ ﻧﺴﺒﺘﺎ ﺑﺰﺭﮒﺗﺮﯼ ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ. ﭘﺮﻭﮊﻩﻫﺎﯾﯽ ﮐﻪ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ LEEDﺍﻧﺠﺎﻡ ﻣﯽﺷﻮﻧﺪ، ﻣﻨﺎﺳــﺐ ﮐﺎﻫﺶ ﻫﺰﯾﻨﻪ ﺍﻧﺮﮊﯼ ﺍﺯ ﻃﺮﯾــﻖ ﮐﺎﺭﺑﺮﺩ ﭼﯿﻠﺮﻫﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺑــﻮﺩﻩ ﻭ ﺩﺭ ﻋﯿﻦ ﺣــﺎﻝ ،ﺑﺎﻋﺚ ﻣﺤﺎﻓﻈﺖ ﻣﻨﺎﺳــﺐ ﭼﯿﻠﺮ ﺍﺯ ﻫﻮﺍﯼ ﺳــﺮﺩ ﻣﺤﯿﻂ ﻣﯽﺷﻮﻧﺪ .ﻣﻘﺎﯾﺴــﻪ ﭼﯿﻠﺮ ﭘﺮﻭﺍﻧﻪﺍﯼ ﻫﻮﺍﯾﯽ ﻫﻤﺮﺍﻩ ﺑﺎ ﻣﺤﻠﻮﻝ ﺿﺪﯾﺦ ،ﺑﺎ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭﯼ ﮐﻪ
ﻋــﺪﻡ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺭﺍﻩﺣﻞ ﺑﺪﻭﻥ ﯾﺦﺯﺩﮔﯽ ﺑــﻪ ﻣﻌﻨﯽ ﮐﺎﻫﺶ ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺑﺎ ﮐﻨﺪﺍﻧﺴــﻮﺭﯼ ﻫﻮﺍﯾﯽ ﮐﻪ ﺍﺯ ﺁﺏ ﺗﺎﺯﻩ ﺑﻬــﺮﻩ ﻣﯽﺑﺮﺩ ﺗﻄﺒﯿﻖ ﺩﺍﺩﻩ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺍﺳﺖ.
ﺷﺪﻩ ،ﻣﺰﯾﺖ ﺍﯾﻦ ﺭﻭﺵ ﺭﺍ ﻧﺸﺎﻥ ﻣﯽﺩﻫﺪ. ﺍﮔــﺮ ﻫﺰﯾﻨﻪ ﻣﺼــﺮﻑ ﺍﻧﺮﮊﯼ ﺳــﺎﻟﯿﺎﻧﻪ ﺳﯿﺴــﺘﻢ ﭼﯿﻠﺮ ﺑﺪﻭﻥ
ﺁﯾﺎ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ ﺑﺎ ﻣﺤﺎﻓﻈﺖ
ﮐﻨﺪﺍﻧﺴﻮﺭ 250ﺗﻦ ،ﻣﻮﺭﺩ ﺍﺭﺯﯾﺎﺑﯽ ﻗﺮﺍﺭ ﮔﯿﺮﺩ ،ﻣﯿﺰﺍﻥ ﺻﺮﻓﻪﺟﻮﯾﯽ
ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ،ﺑﺎﻋﺚ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﻣﯽﺷﻮﺩ؟
ﺩﺭ ﺍﻧــﺮﮊﯼ ،ﻣﻠﻤــﻮﺱ ﺧﻮﺍﻫﺪ ﺑﻮﺩ .ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺑﺮﻧﺎﻣﻪ ﺗﺤﻠﯿﻞ
ﯾﮑﯽ ﺍﺯ ﻣﺰﺍﯾﺎﯼ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ،ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﻫﻮﺍﯼ
ﺳــﺎﻋﺘﯽ ﮐﺮﯾﺮ ،ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺳﺎﻟﯿﺎﻧﻪ ﺩﺑﯿﺮﺳﺘﺎﻧﯽ
ﺳــﺮﺩ ﺑﺪﻭﻥ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺿﺪﯾﺦ ﺍﺳﺖ .ﺑﺎﯾﺪ ﺗﻮﺟﻪ ﺩﺍﺷﺖ ﮐﻪ ﺑﺮﺧﯽ
ﺩﻭﻃﺒﻘﻪ ﺩﺭ ﺍﯾﻨﺪﯾﺎﻧﺎﭘﻮﻟﯿﺲ ،ﺑﻪ ﺻﻮﺭﺕ ﺗﺼﻮﯾﺮ ) (7ﺍﺳﺖ.
ﮐﺎﺭﺑﺮﺩﻫﺎ ﻧﯿﺎﺯﻣﻨﺪ ﻣﺤﻠﻮﻝ ﻣﻨﺎﺳــﺒﯽ ﺿﺪﯾﺦ ﺑﺮﺍﯼ ﮐﺎﻫﺶ ﺍﺣﺘﻤﺎﻝ
ﺻﺮﻓﻪﺟﻮﯾﯽ ﺳــﺎﻟﯿﺎﻧﻪ 20%ﺑﺮﺍﯼ ﭼﯿﻠﺮ ،ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ ﻭ
ﯾﺦﺯﺩﮔﯽ ﻫﺴــﺘﻨﺪ .ﺑﻪﻭﯾﮋﻩ ﻣﺤﺎﻓﻈﺖ ﭼﯿﻠﺮ ﺩﺭﺑﺮﺍﺑﺮ ﺩﻣﺎﯼ 40ﺩﺭﺟﻪ
ﭘﻤﭗﻫﺎﯼ ﺁﺏ ﺳــﺮﺩ ،ﺩﺭ ﺍﯾﻦ ﻣﺜﺎﻝ ﺁﺷﮑﺎﺭ ﺍﺳﺖ .ﺍﯾﻦ ﺻﺮﻓﻪﺟﻮﯾﯽ
ﻓﺎﺭﻧﻬﺎﯾﺖ ﯾﺎ ﮐﻤﺘﺮ ﺍﺯ ﺁﻥ ،ﻧﯿﺎﺯﻣﻨﺪ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻏﻠﻈﺖ ﻣﻨﺎﺳﺐ ﻣﺤﻠﻮﻝ
ﺑﺎﻋﺚ ﺗﻄﺒﯿﻖ ﺑﯿﺸﺘﺮ ﺑﺎ ﻣﻮﺍﺭﺩ LEEDﻭ ﮐﺎﻫﺶ ﮔﺎﺯﻫﺎﯼ ﮔﻠﺨﺎﻧﻪﺍﯼ
ﺿﺪﯾﺦ ﺍﺳــﺖ .ﺑﺎﯾﺪ ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﭼﯿﻠﺮ ﺩﺭﻣﻌﺮﺽ ﻫﻮﺍﯼ ﺳﺮﺩ ﺍﺳﺖ،
ﻣﺎﻧﻨﺪ ﺩﯼﺍﮐﺴﯿﺪﮐﺮﺑﻦ ﻣﯽﺷﻮﺩ .ﺍﻣﺮﻭﺯ ﮐﺎﻫﺶ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ،
ﺑﺨﺶ ﺳﺮﺩﺗﺮ ﺍﺯ ﺍﻧﺠﻤﺎﺩ ﻧﺎﺷﯽ ﺍﺯ ﺩﻣﺎﯼ ﭘﺎﯾﯿﻦ ﻣﮑﺶ ،ﻣﺤﺎﻓﻈﺖ ﺷﻮﺩ.
ﻧﺸــﺎﻧﻪ ﺍﺭﺍﺩﻩ ﺑﺮﺍﯼ ﺣﻔﻆ ﻣﻨﺎﺑﻊ ﺍﺳــﺖ ﺗﺎ ﺑﺘــﻮﺍﻥ ﺩﺭ ﺁﯾﻨﺪﻩ ﻧﯿﺰ ﺍﺯ
ﻫﻤﭽﻨﯿﻦ ﻣﺤﻠﻮﻝﻫﺎﯼ ﺿﺪﯾﺦ ﺑﺎﯾﺪ ﺑﺮﺍﯼ ﻣﺤﺎﻓﻈﺖ ﺍﺯ ﻟﻮﻟﻪﮐﺸﯽ ﺁﺏ
ﺁﻥﻫﺎ ﺑﻬﺮﻩ ﺑﺮﺩ.
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 23ﺷﻤﺎﺭﻩ 30
ﺑــﺎ ﺗﺮﮐﯿــﺐ ﭼﯿﻠﺮ ﺑــﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻗﺮﺍﺭﮔﺮﻓﺘــﻪ ﺩﺭ ﺩﺍﺧﻞ ﺑــﺎ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍﯾﯽ ﮐــﻪ ﺩﺭ ﺑﯿﺮﻭﻥ ﻗــﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ، ﺻﺮﻓﻪﺟﻮﯾﯽ ﺑﯿﺸﺘﺮﯼ ﻧﯿﺰ ﺣﺎﺻﻞ ﺧﻮﺍﻫﺪ ﺷﺪ .ﺍﯾﻦ ﻧﻮﻉ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺷﺎﻣﻞ ﮐﻮﯾﻞﻫﺎﯼ ﮐﻨﺪﺍﻧﺴــﻮﺭ ،ﻓﻦﻫﺎﯾﯽ ﮐﻪ ﺍﺯ ﻧﻈﺮ ﺻﻮﺗﯽ ﻣﯿﺰﺍﻥ ﺷﺪﻩﺍﻧﺪ ،ﻣﻨﺒﻊ ﺁﺏ ،ﻧﺎﺯﻝﻫﺎﯼ ﺍﻓﺸﺎﻥ ،ﯾﮏ ﭘﻤﭗ ﮐﻮﭼﮏ ﺍﻓﺸﺎﻥ ﻭ ﮐﻨﺘﺮﻝﻫﺎﯼ ﭘﺎﯾﻪ ﺍﺳــﺖ .ﺳﯿﺴــﺘﻢ ،ﺍﺯ ﺍﻓﺸــﺎﻧﻪ ﺫﺭﺍﺕ ﺁﺏ ﺑﺮﺍﯼ ﮐﺎﻫﺶ ﺩﻣﺎﯼ ﺳﺮﻣﺎﯾﺸﯽ ﺩﺭﻃﻮﻝ ﺗﺒﺨﯿﺮ ﺁﺏ ،ﺑﻬﺮﻩ ﻣﯽﺑﺮﺩ .ﺗﺒﺨﯿﺮ ﺑﺮ ﺩﻣﺎﯼ ﻣﺮﻃﻮﺏ ﻣﺨﺰﻥ ﺑﯿﺮﻭﻥ ﮐﻪ ﻣﻌﻤﻮﻻ ﮐﻤﺘﺮ ﺍﺯ ﺩﻣﺎﯼ ﺧﺸﮏ ﻣﺨﺰﻥ ﺑﯿﺮﻭﻥ ﺍﺳــﺖ ،ﺍﺳﺘﻮﺍﺭ ﺍﺳﺖ .ﺍﯾﻦ ﺍﻣﺮ ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﺩﻣﺎﯼ ﺳﺮﻣﺎﯾﺸــﯽ ،ﻓﺸــﺎﺭﻫﺎﯼ ﺳﯿﺴــﺘﻢ ﻭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺧﻮﺍﻫﺪ ﺷﺪ. ﺍﯾﻦ ﻣﻘﺎﻟﻪ ﺑﺮ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﻣﺠﺰﺍ ﻣﺘﻤﺮﮐﺰ ﺍﺳــﺖ .ﺍﻟﺒﺘﻪ ﺩﺍﻧﺴــﺘﻦ ﻇﺮﻓﯿﺖ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻣﺠﺰﺍ ﻧﯿﺰ ﺍﻫﻤﯿﺖ ﺯﯾﺎﺩﯼ ﺩﺍﺭﺩ.
ﺗﺼﻮﯾﺮ ) (8ﭼﯿﻠﺮ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ ﻣﻨﺎﺳﺐ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 36ﺍﯾﻨﭻ ﺩﺭﮔﺎﻩ ﺍﺳﺖ.
ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ ،ﺍﻧﺪﺍﺯﻩ ﺻﺤﯿﺢ
ﻓﻀﺎﯼ ﮐﻤﺘﺮ
ﺑـﺮﺍﯼ ﭘﺮﻭﮊﻩ :ﭼﯿﻠﺮ ﻣــﺪﻝ HXA 30ﮐﺮﯾﺮ ﻭ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ
HXA 30ﮐﺮﯾﺮ ،ﻣﻌﻤﻮﻻ ﻣﻨﺎﺳــﺐ ﺍﺳــﺘﺎﻧﺪﺍﺭﺩ 36ﺍﯾﻨﭻ ﺩﺭﮔﺎﻩ ﺑﻮﺩﻩ ﻭ ﺑﺎﻋﺚ ﺳــﻬﻮﻟﺖ ﻧﮕﻬــﺪﺍﺭﯼ ﻭ ﮐﺎﻫــﺶ ﻫﺰﯾﻨﻪﻫﺎﯼ ﻧﺼﺐ ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ
ﻣﯽﺷﻮﺩ )ﺗﺼﻮﯾﺮ .(8 ﺟـﺎﯼ ﮐﻤﺘﺮ ﺩﺭ ﻣﻘﺎﯾﺴـﻪ ﺑـﺎ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠـﺰﺍ :ﻭﻗﺘﯽ ﻓﻀﺎﯼ ﻣﮑﺎﻧﯿﮑﯽ ﺩﺍﺧﻠﯽ ﺩﺭ ﺑﻬﺘﺮﯾﻦ ﺣﺎﻟﺖ ﺑﺎﺷﺪ ،ﭼﺮﺍ ﻣﺎﻟﮏ ﺑﺎﯾﺪ ﺗﻤﺎﯾﻠﯽ ﺑــﻪ ﺍﻓﺰﺍﯾﺶ ﻓﻀﺎﯼ ﻏﯿﺮﻗﺎﺑﻞ ﺍﺟﺎﺭﻩ ﺩﺍﺷــﺘﻪ ﺑﺎﺷــﺪ؟ ﭘﻬﻨﺎﯼ ﭼﯿﻠﺮ ﻣﺪﻝ HXA 30ﺑﻪ ﻣﻘﺪﺍﺭ ﺯﯾﺎﺩﯼ ﮐﻮﭼﮏﺗﺮ ﺍﺯ ﺳﯿﺴــﺘﻢ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﺑﺎ ﻇﺮﻓﯿﺖ ﻣﺸﺎﺑﻪ ﺩﺭ ﺑﺎﺯﺍﺭ ﻓﻌﻠﯽ ﺍﺳﺖ )ﺗﺼﻮﯾﺮ .(9
ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ
ﺗﺼﻮﯾﺮ ) (9ﻣﻘﺎﯾﺴﻪ ﻓﻀﺎﯼ ﺩﺍﺧﻠﯽ -ﭼﯿﻠﺮ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ ﻭ ﭼﯿﻠﺮ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ
ﺩﺭ ﻣﻘﺎﯾﺴﻪ ﺑﺎ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ 250ﺗﻦ ،ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﻣﻨﻄﺒﻖ ﺗﻠﻔﻦ55401278 :
ﺑﺎ ﭼﯿﻠﺮ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ ،ﺍﺭﺗﻔﺎﻋﯽ ﮐﻤﺘﺮ ﺍﺯ ﻧﺼﻒ ﺩﺍﺭﺩ.
ﮔﺴﺘﺮﻩ ﻇﺮﻓﯿﺖ ﻣــﺪﻝ HXA 30ﮐﺮﯾﺮ ﺩﺭ ﮔﺴــﺘﺮﻩ ﻇﺮﻓﯿﺘــﯽ ﺍﺯ 70ﺗﺎ 270 ﺗﻦ ﺑﺮﺍﯼ ﺍﻧﻄﺒﺎﻕ ﺑﺎ ﺑﺴــﯿﺎﺭﯼ ﺍﻟﺰﺍﻣﺎﺕ ﮐﺎﺭﯼ ،ﺩﺭ ﺩﺳﺘﺮﺱ ﺍﺳﺖ. ﺗﺮﮐﯿــﺐ ﺩﻭ ﭼﯿﻠــﺮ ﯾﺎ ﺑﯿــﺶ ﺍﺯ ﺁﻥ ،ﺑﺎﻋﺚ ﺍﻓﺰﺍﯾﺶ ﺑﯿﺸــﺘﺮﯼ ﺩﺭ
ﺳﻄﺢ ﻣﻘﻄﻊ ﭘﺎﯾﯿﻦﺗﺮ
ﻇﺮﻓﯿﺖ ﻭﺍﺣﺪ ﭼﯿﻠﺮ ﻣﯽﺷﻮﺩ.
HFC - 134 aﺑﺮﺍﯼ ﺣﺬﻑ ﻓﺮﺳﺎﯾﺶ ﺍﺯﻥ ﺑﺮﺍﯼ ﻋﺪﻡ ﺍﻧﺘﺸــﺎﺭ ﺳــﺮﻣﺎﯾﺶ ﺑﺮﭘﺎﯾــﻪ ،HCFCﭼﯿﻠﺮ ﻣﺪﻝ HXA 30ﮐﺮﯾــﺮ ﺍﺯ ﺳــﺮﻣﺎﯾﺶ HFC - 134 aﺑــﺮﺍﯼ ﺣــﺬﻑ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﺼﻮﯾﺮ ) (10ﺳﻄﺢ ﻣﻘﻄﻊ ﭘﺎﯾﯿﻦ ﭼﯿﻠﺮ ﻣﺪﻝ HXA 30 ﮐﺮﯾﺮ ﺩﺭ ﻣﻘﺎﯾﺴﻪ ﺑﺎ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺳﻄﺢ ﭘﺎﯾﯿﻦﺗﺮ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻨﺎﺳـﺐ ﭼﯿﻠـﺮ ﺑﺎ ﺍﺳـﺘﺎﻧﺪﺍﺭﺩ 36ﺍﯾﻨـﭻ ﺩﺭﮔﺎﻩ :ﭼﯿﻠﺮ ﻣﺪﻝ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻣﻨﻄﺒﻖ ﺷﺪﻩ ،ﮔﺴﺘﺮﻩﺍﯼ ﺍﺯ ﺗﻨﻮﻉ ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫﺎ ﺭﺍ ﺩﺭﺑﺮﻣﯽﮔﯿﺮﻧﺪ.
ﺻﻔﺤﻪ / 24ﺷﻤﺎﺭﻩ 30
ﺧﺮﻭﺝ HCFC ﭘﺮﻭﺗﮑﻞ ﻣﻮﻧﺘﺮﺍﻝ ،2007ﺍﯾﺎﻻﺕ ﻣﺘﺤﺪﻩ ﻭ ﮐﺸﻮﺭﻫﺎﯼ ﺗﻮﺳﻌﻪ ﯾﺎﻓﺘﻪ
ﭘﺮﻭﺗﮑﻞ ﻣﻮﻧﺘﺮﺍﻝ ﭘﯿﺸﯿﻦ 25%ﭘﺮﻭﺗﮑﻞ ﻣﻮﻧﺘﺮﺍﻝ 2007
ﺑﺪﻭﻥ ﺗﺠﻬﯿﺰﺍﺕ ﺟﺪﯾﺪ
ﺗﺼﻮﯾﺮ ) (11ﭘﺮﻭﺗﮑﻞ ﻣﻮﻧﺘﺮﺍﻝ ،ﺧﺮﻭﺝ ﻣﺎﺩﻩ ﺳﺮﻣﺎﯾﺸﯽ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﻓﺮﺳﺎﯾﺶ ﺍﺯﻥ ،ﺑﻬﺮﻩ ﻣﯽﺑﺮﺩ )ﺗﺼﻮﯾﺮ .(11
ﭘﺎﯾﯿﻦ ﺑﺎﺷﺪ.
ﭼﯿﻠﺮﻫــﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ،ﻣﺰﺍﯾﺎﯼ ﺯﯾﺎﺩﯼ ﺩﺭ ﻣﻘﺎﯾﺴــﻪ ﺑﺎ ﭼﯿﻠﺮﻫﺎﯾﯽ ﺑﺎ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﺩﺍﺭﻧﺪ.
ﻟﻮﻟﻪ ﻣﮑﺶ ﺗﺴﺖﺷﺪﻩ ﺗﻮﺳﻂ ﮐﺎﺭﺧﺎﻧﻪ ﻫﺰﯾﻨﻪ ﻧﺼﺐ ﮐﻤﺘﺮ ،ﺑﺪﻭﻥ ﻧﯿﺎﺯ ﺑﻪ ﺩﯾﻮﺍﺭ /ﻋﺎﯾﻖ ﺻﺪﺍﯼ ﺧﺎﺭﺟﯽ
ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ ،ﺗﺼﻮﯾﺮ )(12
ﻫﻤﺮﺍﻩ ﺑﺎ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ،AZ 90ﺑﺪﻭﻥ ﻧﯿﺎﺯ ﺑﻪ ﻣﺤﺎﻓﻆ ﺗﮕﺮﮒ
ﻣﺰﺍﯾﺎﯼ ﺯﯾــﺎﺩﯼ ﻭﺭﺍﯼ ﻣﺤﺎﻓﻈﺖ ﺧﻮﺏ ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ﻭ ﮐﺎﻫﺶ ﺁﺳﺎﻥﺗﺮ ﺻﺪﺍ ﺩﺭ ﻣﻘﺎﯾﺴﻪ ﺑﺎ ﭼﯿﻠﺮﻫﺎﯾﯽ ﺑﺎ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ﻣﺠﺰﺍ ﺩﺍﺭﻧﺪ.
ﮐﺎﻫﺶ ﺑﺎﺭ ﺑﺮ ﺳﻘﻒ ﻭ ﻫﺰﯾﻨﻪ ﺳﺎﺧﺘﻤﺎﻧﯽ ﮐﻤﺘﺮ
ﭼﯿﻠﺮﻫﺎﯼ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ،ﻣﺰﺍﯾﺎﯼ ﺯﯾﺮ ﺭﺍ ﺩﺍﺭﻧﺪ.
ﻧﮕﻬﺪﺍﺭﯼ ﺁﺳﺎﻥﺗﺮ ﺑﺎ ﺗﺠﻬﯿﺰﺍﺕ ﺩﺍﺧﻠﯽ
ﻣﺤﺎﻓﻈﺖ ﺩﺭﺑﺮﺍﺑﺮ ﯾﺦﺯﺩﮔﯽ ﺁﺳﺎﻥﺗﺮ
ﺗﻨﺎﺳﺐ ﺑﻬﺘﺮ ﺩﺭﻭﻥ ﺳﺎﺧﺘﻤﺎﻥ
ﮐﺎﻫﺶ ﺳﻄﻮﺡ ﺻﺪﺍﯼ ﺑﯿﺮﻭﻥ ،ﺣﺘﺎ ﮐﻤﺘﺮ ﺍﺯ ﻓﻦ ﮐﻨﺪﺍﻧﺴﻮﺭ
ﺳﺮﻣﺎﯾﺶ ﺑﻠﻨﺪﻣﺪﺕ ﺑﺎ HFC - 134 aﺑﺮﺍﯼ ﺣﺬﻑ ﻓﺮﺳﺎﯾﺶ ﺍﺯﻥ
ﺟﺎﯼ ﮐﻤﺘﺮﯼ ﺩﺭ ﺩﺍﺧﻞ ﺍﺷﻐﺎﻝ ﻣﯽﮐﻨﺪ.
ﮐﺎﻫــﺶ ﻣﺼﺮﻑ ﺍﻧــﺮﮊﯼ ﻭ ﮐﻤﮏ ﺑﻪ ﮔﺴــﺘﺮﺵ ﺍﺳــﺘﺎﻧﺪﺍﺭﺩ LEED
ﺗﻠﻔﻦ88739880-2:
ﺳــﻄﺢ ﻣﻘﻄﻊ ﺧﺎﺭﺟﯽ ﭘﺎﯾﯿﻦﺗﺮ ،ﻣﯽﺗﻮﺍﻧﺪ ﺗﺎ 3ﻓﻮﺕ ﻭ 7ﺍﯾﻨﭻ ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﺼﻮﯾﺮ ) (12ﭼﯿﻠﺮ ﺑﺪﻭﻥ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻣﺪﻝ HXA 30ﮐﺮﯾﺮ
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 25ﺷﻤﺎﺭﻩ 30
ﻋﻠﻤﻰ
ﺑﺎﺯﻳﺎﺑﻰ ﮔﺮﻣﺎ ﺍﺯ ﭼﻴﻠﺮﻫﺎﻯ ﻫﻮﺍﻳﻰ ﺍﻓﺰﺍﯾــﺶ ﮐﺎﺭﺍﯾﯽ ﺑﻪ ﺑﯿﺶ ﺍﺯ 100%ﻣﯽﺷــﻮﺩ .ﺍﯾــﻦ ﺍﻣﺮ ﺩﺭﻧﺘﯿﺠﻪ
ﻣﻘﺪﻣﻪ
ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺍﻧﺮﮊﯼ ﺑﻪ ﺩﺳــﺖ ﺁﻣﺪﻩ ﺍﺯ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎ ،ﻋﻼﻭﻩ ﺑﺮ ﺗﺎﺛﯿﺮ
ﭼﺮﺍ ﺑﺎﺯﯾﺎﺑﯽ ﮔﺮﻣﺎ ﺍﻫﻤﯿﺖ ﺩﺍﺭﺩ؟
ﺳﺮﻣﺎﯾﺸــﯽ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ ،ﺭﻭﯼ ﻣﯽﺩﻫﺪ .ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺍﯾﻦ ﺩﻭ ﻣﻨﺒﻊ
40%ﻣﺼــﺮﻑ ﺍﻧﺮﮊﯼ ﭘﺎﯾﻪ ﺩﺭ ﺍﯾﺎﻻﺕ ﻣﺘﺤﺪﻩ ﺑﻪ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎ ﻣﺮﺑﻮﻁ ﺷــﺪﻩ ﻭ 43%ﺍﻧﺮﮊﯼ ﻣﺼﺮﻓﯽ ﺩﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺗﺠﺎﺭﯼ ﺑﻪ ﮔﺮﻣﺎﯾﺶ ﻣﺤﯿﻂ ﻭ ﺁﺏ ﺑﺮﻣﯽﮔﺮﺩﺩ )ﺗﺼﻮﯾﺮ .(1ﺍﮔﺮ ﺑﻪ ﻃﻮﺭ ﻣﻮﺛﺮﺗﺮﯼ
ﺑﺮﺍﯼ ﺍﻫﺪﺍﻑ ﺳﺮﻣﺎﯾﺸﯽ ﻭ ﮔﺮﻣﺎﯾﺸﯽ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ ،ﻣﯽﺗﻮﺍﻧﺪ ﺑﻪ ﺑﯿﺶ ﺍﺯ 5ﺑﺮﺳﺪ. COP total = Heat out / Work in + Heat in / Work in
ﺧﻮﺍﻫﺪ ﺩﺍﺷﺖ .ﺍﯾﻦ ﻣﻘﺎﻟﻪ ﺑﻪ ﺟﺴﺖﻭﺟﻮﯼ ﺭﺍﻩﻫﺎﯼ ﻣﻮﺛﺮﺗﺮﯼ ﺑﺮﺍﯼ ﺗﻮﻟﯿﺪ ﺁﺏ ﮔﺮﻡ ﺍﺯ ﻃﺮﯾﻖ ﺳﯿﺴﺘﻢﻫﺎﯼ ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺑﺎ ﻗﺎﺑﻠﯿﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﺳﺖ ﺗﺎ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺩﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎ ﮐﺎﻫﺶ ﯾﺎﺑﺪ.
ﻣﻌﺎﺩﻟﻪ )(1 ﺿﺮﯾﺐ ﮐﺎﺭﺍﯾﯽ ﺑﺮﺍﯼ ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ +ﺁﺏ ﺧﻨﮏﺷﺪﻩ ﺍﮔــﺮ ﺑﻪ ﻋﻤﻠﮑﺮﺩ ﭼﯿﻠﺮ ﻫﻮﺍﯾــﯽ 120ﺗﻦ ﺗﮏ ﺑﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺍﻓﺰﺍﯾﺶ ﮐﺎﺭﺍﯾﯽ ﺩﺭ ﺗﻮﻟﯿﺪ ﺁﺏ ﮔﺮﻡ
ﺑﻨﮕﺮﯾــﻢ ،ﻣﺰﺍﯾــﺎﯼ ﺍﻧــﺮﮊﯼ ﺭﺍ ﺑﺮ ﭘﺎﯾــﻪ ﺿﺮﯾﺐ ﻋﻤﻠﮑﺮﺩ ﻣﺸــﺎﻫﺪﻩ
ﺑﺮﺍﯼ ﺳــﺎﻝﻫﺎ ،ﺁﺏ ﮔﺮﻡ ﺍﻏﻠﺐ ﺑﺎ ﺭﻭﺷﯽ ﻣﺸﺎﺑﻪ ﺑﻪ ﺩﺳﺖ ﺁﻣﺪﻩ
ﻣﯽﮐﻨﯿﻢ.
ﺍﺳــﺖ .ﺳــﻮﺧﺖﻫﺎﯼ ﻓﺴــﯿﻠﯽ ﺩﺭ ﺍﻃﺮﺍﻑ ﻣﺨﺰﻧﯽ ﭘﺮﺷﺪﻩ ﺑﺎ ﺁﺏ،
ﻋﻤﻠﮑﺮﺩ ﭼﯿﻠﺮ ﺩﺭ ﺩﻣﺎﯼ 44ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺁﺏ ﺳﺮﺩ ،ﺟﺮﯾﺎﻥ
ﺳــﻮﺧﺘﻪ ﻭ ﺁﻥ ﺭﺍ ﮔﺮﻡ ﮐﺮﺩﻩﺍﻧﺪ .ﺩﺭ ﺍﯾﻦ ﺍﻭﺍﺧﺮ ﺍﺯ ﺍﻟﻤﻨﺖﻫﺎﯼ ﺑﺮﻗﯽ
ﺍﻭﺍﭘﺮﺍﺗــﻮﺭ 2.5gpm / tonﺑﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗــﯽ ،ﺗﻮﻟﯿﺪ 121ﺩﺭﺟﻪ
ﻗﺮﺍﺭﮔﺮﻓﺘﻪ ﺑﺮﺍﯼ ﮔﺮﻡ ﮐﺮﺩﻥ ﺁﺏ ﺍﺳــﺘﻔﺎﺩﻩ ﺷــﺪﻩ ﺍﺳﺖ .ﻭﻗﺘﯽ ﺁﺏ
ﻓﺎﺭﻧﻬﺎﯾــﺖ ﺩﻣــﺎﯼ ﺁﺏ ﻭﺭﻭﺩﯼ ﺍﺣﯿــﺎﯼ ﮔﺮﻣﺎﯾﺸــﯽ ﻭ 131ﺩﺭﺟﻪ
ﺑﺎ ﺳــﻮﺧﺖﻫﺎﯼ ﻓﺴــﯿﻠﯽ ﮔﺮﻡ ﻣﯽﺷــﻮﺩ ،ﮐﺎﺭﺍﯾﯽ ﺑﻪ ﺑﯿﺶ ﺍﺯ 90%
ﻓﺎﺭﻧﻬﺎﯾﺖ ﺩﻣﺎﯼ ﺁﺏ ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾﺸﯽ ﺧﺮﻭﺟﯽ:
ﺁﺏ ،ﻣﻘــﺪﺍﺭ ﺁﻥ ﺗــﺎ 100%ﻧﯿــﺰ ﺍﻓﺰﺍﯾﺶ ﻣﯽﯾﺎﺑﺪ .ﺍﯾــﻦ ﮐﺎﺭﺍﯾﯽ ﺑﻪ
ﺗﻮﺍﻥ ﻭﺭﻭﺩﯼ
ﻋﻨﻮﺍﻥ ﺿﺮﺍﯾﺐ ﻋﻤﻠﮑﺮﺩ 0.9ﻭ 1ﺷــﻨﺎﺧﺘﻪ ﻣﯽﺷﻮﺩ .ﺁﯾﺎ ﻣﯽﺗﻮﺍﻧﺪ
ﺧﺮﻭﺟﯽ ﮔﺮﻣﺎﯾﺸﯽ
ﺍﯾﻦ ﺿﺮﯾﺐ ﻋﻤﻠﮑﺮﺩ ﺑﻪ ﺑﯿﺶ ﺍﺯ 1ﺑﺮﺳــﺪ؟ ﭘﺎﺳﺦ ،ﻣﺜﺒﺖ ﺍﺳﺖ .ﺑﺎ
COP total = 480.7 kW + 329.6 kW / 159.9 kW = 5.07
ﻣﯽﺷﻮﺩ ،ﮔﺮﻓﺘﻪ ﻭ ﺑﺮﺍﯼ ﺣﺮﺍﺭﺕ ﻣﻔﯿﺪ ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﻫﻤﺎﻥﻃﻮﺭ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ ) (2ﺩﯾﺪﻩ ﻣﯽﺷﻮﺩ ،ﺍﻣﮑﺎﻥ ﮔﺮﻓﺘﻦ ﺍﯾﻦ ﺍﻧﺮﮊﯼ ﺧﺎﺭﺝﺷﺪﻩ ﺍﺯ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻭ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺁﻥ ﺑﺮﺍﯼ ﺗﻮﻟﯿﺪ ﺁﺏ ﮔﺮﻡ ﻭﺟﻮﺩ ﺩﺍﺭﺩ .ﺑﺎ ﮔﺮﻓﺘﻦ ﺍﯾﻦ ﺣﺮﺍﺭﺕ ﮐﻪ ﺗﻠﻒ ﻣﯽﺷﺪ ،ﮐﺎﺭﺍﯾﯽ ﮐﻞ ﺳﯿﺴﺘﻢ ﺑﻪ ﻣﯿﺰﺍﻥ ﺯﯾﺎﺩﯼ ﺍﻓﺰﺍﯾﺶ ﻣﯽﯾﺎﺑﺪ.
(MBH) 480.7 kW 1642
ﻣﻌﺎﺩﻟﻪ )(2 ﺿﺮﯾــﺐ ﮐﺎﺭﺍﯾﯽ ﺑﺮﺍﯼ ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ +ﺁﺏ ﺧﻨﮏﺷــﺪﻩ ﺑﺮﺍﯼ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺑﺎ ﻗﺎﺑﻠﯿﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﭼﯿﻠــﺮ ﻫﻮﺍﯾﯽ ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﻣﻘﺪﺍﺭ ﻗﺎﺑــﻞ ﻣﻼﺣﻈﻪﺍﯼ ﺣﺮﺍﺭﺕ ﺭﺍ
ﺑﺮﺧﻼﻑ ﺭﻭﻧﺪ ﺗﻮﻟﯿﺪ ﺣﺮﺍﺭﺕ ﺍﺯ ﺍﺣﺘﺮﺍﻕ ﯾﺎ ﺍﻟﮑﺘﺮﯾﺴــﯿﺘﻪ ﻧﺎﺷﯽ
ﺍﺯ ﻃﺮﯾﻖ ﮐﻨﺪﺍﻧﺴــﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ ﺧﻮﺩ ﺑﻪ ﺑﯿﺮﻭﻥ ﻣﯽﻓﺮﺳــﺘﺪ ،ﺁﺏ
ﺍﺯ ﻫﯿﺘﺮﻫــﺎﯼ ﺁﺑﯽ ،ﮔﺮﻓﺘﻦ ﺍﻧﺮﮊﯼ ﺗﻠﻒﺷــﺪﻩ ﺍﺯ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺑﺎﻋﺚ
ﺳــﺮﺩ ﺗﻮﻟﯿﺪ ﻣﯽﮐﻨﺪ .ﺍﮔﺮ ﺑﺘــﻮﺍﻥ ﺍﯾﻦ ﺣــﺮﺍﺭﺕ ﺭﺍ ﮔﺮﻓﺘﻪ ﻭ ﺩﻭﺑﺎﺭﻩ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﻠﻔﻦ55401278 :
ﺑﺎﺯﯾﺎﻓﺖ ﺣﺮﺍﺭﺗﯽ ﻣﯽﺗﻮﺍﻥ ﺁﻥ ﺍﻧﺮﮊﯼ ﺭﺍ ﮐﻪ ﺩﺭ ﻣﺤﯿﻂ ﻣﻨﺘﺸﺮ ﻭ ﺗﻠﻒ
kW 159.9
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺩﺭ ﺑﻮﯾﻠﺮ ﻧﻮﻉ ﭼﮕﺎﻟﻨﺪﻩ ﺭﺳــﯿﺪﻩ ﻭ ﺩﺭ ﺍﻟﻤﻨﺖﻫﺎﯼ ﺑﺮﻗﯽ ﮔﺮﻡﮐﻨﻨﺪﻩ
ﻇﺮﻓﯿﺖ ﺳﺮﻣﺎﯾﺸﯽ
93.7ﺗﻦ )(kW 329.6
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺩﺭ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎ ﻭ ﺩﺭﻧﺘﯿﺠﻪ ﺍﯾﺎﻻﺕ ﻣﺘﺤﺪﻩ ،ﻭﺟﻮﺩ
ﺩﺭﺣﻘﯿﻘﺖ ،ﺿﺮﯾﺐ ﮐﺎﺭﺍﯾﯽ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﺯ ﺳﯿﺴــﺘﻢ ﭼﯿﻠﺮﯼ ﮐﻪ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺍﺯ ﺗﺎﻣﯿﻦ ﺣﺮﺍﺭﺕ ﺑﻬﺮﻩ ﮔﺮﻓﺘﻪ ﺷــﻮﺩ ،ﺷــﺎﻧﺲ ﺯﯾﺎﺩﯼ ﺑﺮﺍﯼ ﮐﺎﻫﺶ
ﺣﺮﺍﺭﺗﯽ ،ﺭﺳﯿﺪﻥ ﮐﺎﺭﺍﯾﯽ ﺑﻪ ﺑﯿﺶ ﺍﺯ 100%ﺍﻣﮑﺎﻥﭘﺬﯾﺮ ﺧﻮﺍﻫﺪ ﺷﺪ.
ﺻﻔﺤﻪ / 26ﺷﻤﺎﺭﻩ 30
ﺩﯾﮕﺮ 569 ،ﺗﺮﯾﻠﯿﻮﻥ BTU
ﺗﺠﻬﯿﺰﺍﺕ ﺍﺩﺍﺭﯼ 69 ،ﺗﺮﯾﻠﯿﻮﻥ BTU ﮐﺎﻣﭙﯿﻮﺗﺮﻫﺎ 156 ،ﺗﺮﯾﻠﯿﻮﻥ BTU ﺁﺷﭙﺰﯼ 190 ،ﺗﺮﯾﻠﯿﻮﻥ BTU ﺗﺒﺮﯾﺪ381 ، ﺗﺮﯾﻠﯿﻮﻥ BTU
ﮔﺮﻣﺎﯾﺶ ﻣﺤﯿﻂ2365 ، ﺗﺮﯾﻠﯿﻮﻥ BTU
ﺗﻬﻮﯾﻪ436 ، ﺗﺮﯾﻠﯿﻮﻥ BTU ﮔﺮﻡ ﮐﺮﺩﻥ ﺁﺏ، 501ﺗﺮﯾﻠﯿﻮﻥ BTU
ﺁﺏ ﮔﺮﻡ ﻭﺭﻭﺩﯼ ﮐﻤﺘﺮ ﺍﺯ ﻧﻘﻄﻪ ﺩﻟﺨﻮﺍﻩ ﺑﺎﺷﺪ ،ﺑﻪ ﻃﻮﺭ ﺧﻮﺩﮐﺎﺭ ﯾﮑﯽ ﺍﺯ ﻣﺪﺍﺭﻫﺎﯼ ﺳﺮﻣﺎﯾﺸﯽ ﺑﻪ ﺣﺎﻟﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺩﺭﻣﯽﺁﯾﺪ )ﺗﺼﻮﯾﺮ .(4ﭼﯿﻠﺮ ﺍﮐﻨﻮﻥ ﺑﯿﺸــﺘﺮ ﺷﺒﯿﻪ ﯾﮏ ﭼﯿﻠﺮ ﺁﺏ ﺧﻨﮏ ﺑﺎ ﯾﮏ ﻣﺪﺍﺭ ﻭ ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺑﺎ ﻣﺪﺍﺭ ﺩﯾﮕﺮ ،ﻋﻤﻞ ﻣﯽﮐﻨﺪ .ﺑﺴﺘﻪ ﺑﻪ ﺩﻣﺎﯼ ﻭﺭﻭﺩﯼ ﺁﺏ ﮔﺮﻡ ﻭ ﺗﻔﺎﻭﺕ ﺁﻥ ﺑﺎ ﻧﻘﻄﻪ ﻣﻮﺭﺩ ﻧﻈﺮ ،ﻣﺪﺍﺭ ﺩﻭﻣﯽ ﻧﯿﺰ ﻣﯽﺗﻮﺍﻧﺪ ﺍﺯ ﻃﺮﯾﻖ ﮐﻨﺘﺮﻝﻫﺎﯼ ﭘﯿﻮﺳﺘﻪ ﺑﻪ ﺣﺎﻟﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺩﺭﺁﯾﺪ .ﺩﻣﺎﯼ ﺁﺏ ﮔــﺮﻡ ﻭﺭﻭﺩﯼ ﺑﻪ ﻭﺳــﯿﻠﻪ ﺗﻐﯿﯿﺮ ﻫﺮ ﻣﺪﺍﺭ ﺳﺮﻣﺎﯾﺸــﯽ ﺍﺯ ﺣﺎﻟﺖ ﺧﻨﮏ ﺷﺪﻥ ﺑﻪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﮐﻨﺘﺮﻝ ﻣﯽﺷﻮﺩ .ﻭﻗﺘﯽ ﺁﺏ ﮔﺮﻡ ﺑﻪ
ﺳﺮﻣﺎﯾﺶ516 ، ﺗﺮﯾﻠﯿﻮﻥ BTU
ﻣﺼﺮﻑ ﮐﻞ6523 ، ﺗﺮﯾﻠﯿﻮﻥ BTU
ﻧﻘﻄﻪ ﻣﻮﺭﺩ ﻧﻈﺮ ﺭﺳﯿﺪ ،ﭼﯿﻠﺮ ﺑﻪ ﺻﻮﺭﺕ ﺣﺎﻟﺖ ﺧﻨﮏ ﺷﺪﻥ ﺩﺭﺁﻣﺪﻩ
ﺭﻭﺷﻨﺎﯾﯽ1340 ، ﺗﺮﯾﻠﯿﻮﻥ BTU
ﮔﺮﻣﺎﯾﺶ ﺧﺮﻭﺟﯽ
ﺗﺼﻮﯾﺮ ) (1ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺩﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺗﺠﺎﺭﯼ ،2003ﻋﻤﺪﻩ ﻣﺼﺮﻑ ﺳﻮﺧﺖ ﺑﻪ ﻭﺳﯿﻠﻪ ﺍﺳﺘﻔﺎﺩﻩ ﻧﻬﺎﯾﯽ ﺗﻤﺎﻡ ﺳﺎﺧﺘﻤﺎﻥﻫﺎ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺷﯿﺮ ﺍﻧﺒﺴﺎﻁ ﮐﺎﺭ ﻭﺭﻭﺩﯼ )ﺍﻟﮑﺘﺮﯾﺴﯿﺘﻪ(
ﺑﻪ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ ﺑﺎﺯﮔﺮﺩﺍﻧﺪ ،ﺳﯿﺴﺘﻢ ﻧﻪﺗﻨﻬﺎ ﻣﯽﺗﻮﺍﻧﺪ ﻣﻨﺒﻌﯽ ﮐﻨﺘﺮﻝﺷﺪﻩ ﺍﺯ ﺁﺏ ﺳــﺮﺩ ﻓﺮﺍﻫﻢ ﺁﻭﺭﺩ ،ﻣﻘﺪﺍﺭ ﺯﯾﺎﺩﯼ ﺣﺮﺍﺭﺕ ﻣﻔﯿﺪ
ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﺑــﺮﺍﯼ ﺗﻮﻟﯿﺪ ﺁﺏ ﮔﺮﻡ ﺧﻮﺍﻫﺪ ﺩﺍﺷــﺖ .ﭼﯿﻠﺮﻫــﺎﯼ ﻫﻮﺍﯾﯽ ﮐﺮﯾﺮ ﺑﺎ ﮐﻤﭙﺮﺳﻮﺭ
ﻗﺎﺑﻠﯿﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﭼﻨﯿﻦ ﻣﯽﮐﻨﻨﺪ ،ﺁﺏ ﺳﺮﺩ ﮐﻨﺘﺮﻝﺷﺪﻩﺍﯼ ﺭﺍ ﺑــﺎ ﺩﻣﺎﯼ ﻣﻮﺭﺩ ﻧﻈﺮ ﺗﻮﻟﯿــﺪ ﻭ ﺩﺭﻋﯿﻦ ﺣﺎﻝ ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﺤﺼﻮﻟﯽ ﺟﺎﻧﺒﯽ ﺍﺯ ﺳﯿﺴﺘﻢ ﺁﺏ ﺳﺮﺩ ،ﺁﺏ ﮔﺮﻡ ﺑﻪ ﺩﺳﺖ ﻣﯽﺁﻭﺭﻧﺪ.
ﮔﺮﻣﺎﯾﺶ ﻭﺭﻭﺩﯼ
ﺗﺼﻮﯾﺮ ) (2ﺭﺍﺑﻄﻪ ﮐﺎﺭ ﻭ ﮔﺮﻣﺎﯾﺶ ﺩﺭ ﯾﮏ ﺳﯿﺴﺘﻢ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ
ﻧﺤﻮﻩ ﻋﻤﻞ ﺁﻥ ﭼﮕﻮﻧﻪ ﺍﺳﺖ؟ ﺩﺭ ﺷﺮﺍﯾﻂ ﻣﻌﻤﻮﻝ ﺧﻨﮏ ﮐﺮﺩﻥ ،ﭼﯿﻠﺮ ﻣﻨﺒﻌﯽ ﮐﻨﺘﺮﻝﺷﺪﻩ ﺍﺯ ﺁﺏ ﺳــﺮﺩ ﺭﺍ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﻫﻮﺍﯾﯽ ﺧﻮﺩ ﺗﻮﻟﯿﺪ ﻣﯽﮐﻨﺪ.
ﺳﯿﺴﺘﻢ ﺁﺏ ﮔﺮﻡ ﺷﯿﺮ ﮐﻨﺘﺮﻟﯽ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ
ﺗﻮﻟﯿﺪ ﻣﻨﺒﻊ ﮐﻨﺘﺮﻝﺷــﺪﻩﺍﯼ ﺍﺯ ﺁﺏ ﺳﺮﺩ ﺧﺮﻭﺟﯽ ﺑﺎ ﺩﻣﺎﯼ ﺩﻟﺨﻮﺍﻩ ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺩﺭ ﺍﯾﻦ ﺣﺎﻟﺖ ،ﺳﯿﺴــﺘﻢ ﻣﺎﻧﻨﺪ ﯾﮏ ﭼﯿﻠــﺮ ﻫﻮﺍﯾﯽ ﻣﻌﻤﻮﻟﯽ ﺑﺮﺍﯼ ﻋﻤﻞ ﮐﺮﺩﻩ ﻭ ﺣﺮﺍﺭﺕ ﺭﺍ ﺍﺯﻃﺮﯾﻖ ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﺧﻮﺩ ،ﺩﺭ ﻣﺤﯿﻂ ﺑﺴﺘﻪ
ﻣﻨﺘﺸﺮ ﻣﯽﮐﻨﺪ )ﺗﺼﻮﯾﺮ .(3
ﺗﻮﺟﻪ ﺩﺍﺷﺖ ﮐﻪ ﺍﯾﻦ ﭼﯿﻠﺮ ﻫﻤﻮﺍﺭﻩ ﺩﻣﺎﯼ ﺁﺏ ﺳﺮﺩ ﺧﺮﻭﺟﯽ ﺭﺍ ﺗﺎﻣﯿﻦ
ﺑﺴﺘﻪ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ
ﻭﻗﺘــﯽ ﭼﯿﻠﺮﯼ ﻫﻮﺍﯾﯽ ﺩﺭ ﺣﺎﻟﺖ ﺑﺎﺯﯾﺎﺑــﯽ ﺣﺮﺍﺭﺗﯽ ﻋﻤﻞ ﮐﻨﺪ، ﺑﺎﯾﺪ ﻧﯿﺎﺯ ﻣﺸﺎﺑﻬﯽ ﺑﻪ ﺁﺏ ﺳﺮﺩ ﻭ ﺁﺏ ﮔﺮﻡ ،ﻭﺟﻮﺩ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ .ﺑﺎﯾﺪ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ
ﺷﯿﺮ ﺍﻧﺒﺴﺎﻁ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﮐﻨﺪ .ﺩﺭﻧﺘﯿﺠﻪ ﭼﯿﻠﺮ ﺗﺎ ﺟﺎﯼ ﻣﻤﮑﻦ ،ﺁﺏ ﮔﺮﻡ ﺗﻮﻟﯿﺪ ﺧﻮﺍﻫﺪ ﮐﺮﺩ، ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﺩﻣﺎﯼ ﺁﺏ ﺳﺮﺩ ﺧﺮﻭﺟﯽ ،ﮐﻨﺘﺮﻝﺷﺪﻩ ﺍﺳﺖ .ﺩﻣﺎﯼ ﺁﺏ
ﮐﻤﭙﺮﺳﻮﺭ
ﮔﺮﻡ ﺧﺮﻭﺟﯽ ،ﺑﺎﺯﺗﺎﺑﯽ ﺍﺯ ﭼﺮﺧﻪ ﺳــﺮﻣﺎﯾﺶ ﺍﺳﺖ .ﺑﺮﺍﯼ ﺗﻮﻟﯿﺪ ﺁﺏ
ﺳﯿﺴﺘﻢ ﺁﺏ ﺧﻨﮏ
ﮔﺮﻡ ،ﺩﻣﺎﯼ ﺁﺏ ﮔﺮﻡ ﻭﺭﻭﺩﯼ ﺩﺭﻣﻘﺎﯾﺴﻪ ﺑﺎ ﻣﻘﺪﺍﺭ ﺩﻟﺨﻮﺍﻩ ،ﺑﻪ ﻋﻨﻮﺍﻥ ﻧﻘﻄﻪ ﺍﺣﯿﺎ ﺷﻨﺎﺧﺘﻪ ﺷﺪﻩ ﻭ ﺑﺮﺍﯼ ﺗﻌﯿﯿﻦ ﻣﻘﺪﺍﺭ ﻣﺪﺍﺭﻫﺎﯼ ﻣﻮﺭﺩ ﻧﯿﺎﺯ ﺑﺮﺍﯼ ﺗﺎﻣﯿﻦ ﺩﻣﺎﯼ ﺁﺏ ﮔﺮﻡ ﻭﺭﻭﺩﯼ ،ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ .ﺍﮔﺮ ﺩﻣﺎﯼ ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺗﺼﻮﯾﺮ ) (3ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺑﺎ ﻗﺎﺑﻠﯿﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﺣﺎﻟﺖ ﺳﺮﻣﺎﯾﺶ ﺗﮏ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 27ﺷﻤﺎﺭﻩ 30
ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺁﺏ ﮔﺮﻡ ﺩﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎ
ﺳﯿﺴﺘﻢ ﺁﺏ ﮔﺮﻡ
ﺩﺍﻧﺴــﺘﻦ ﻧﻮﻉ ﺑﻨﺎ ﯾﺎ ﻓﺮﺁﯾﻨﺪ ﭼﮕﻮﻧﮕﯽ ﮐﺴﺐ ﮔﺮﻣﺎ ﺑﺮﺍﯼ ﮐﺎﺭﺑﺮﺩ ﻣﻮﺭﺩ ﻧﻈــﺮ ،ﺍﻫﻤﯿﺖ ﺯﯾﺎﺩﯼ ﺩﺍﺭﺩ .ﺍﺯ ﺁﺏ ﮔــﺮﻡ ﻣﯽﺗﻮﺍﻥ ﺑﺮﺍﯼ ﮔﺮﻡ
ﺷﯿﺮ ﮐﻨﺘﺮﻟﯽ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ
ﮐــﺮﺩﻥ ﯾﮏ ﺑﻨﺎ ﯾﺎ ﭘﯿﺶﮔﺮﻣﺎﯾﺶ ﺗﻬﻮﯾﻪ ﻫــﻮﺍ ،ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﮐﻮﯾﻞﻫﺎ،
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ
ﺗﺎﻣﯿﻦ ﺷﺮﺍﯾﻂ ﺍﺳﺘﺨﺮ ،ﭘﯿﺶﮔﺮﻣﺎﯾﺶ ﺁﺏ ﺧﺎﻧﮕﯽ ﯾﺎ ﮔﺮﻡ ﮐﺮﺩﻥ ﯾﮏ ﻓﺮﺁﯾﻨﺪ ،ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﻫﺮ ﯾﮏ ﺍﺯ ﺍﯾﻦ ﮐﺎﺭﺑﺮﺩﻫﺎ ﻧﯿﺎﺯﻣﻨﺪ ﻣﻼﺣﻈﺎﺕ ﻣﺸــﺎﺑﻬﯽ ﺩﺭ ﺯﻣﯿﻨﻪ ﺁﺏ ﺳﺮﺩ ﻭ ﺁﺏ ﮔﺮﻡ ﻫﺴــﺘﻨﺪ .ﺍﯾﻦ ﺍﻟﺰﺍﻣﺎﺕ ﺭﺍ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﻫﻮﺍﯾﯽ ﺑﺴﺘﻪ
ﺑﺴﺘﻪ
ﻣﯽﺗﻮﺍﻥ ﺩﺭ ﻫﺮ ﯾﮏ ﺍﺯ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯾﯽ ﮐﻪ ﺩﺭ ﺯﯾﺮ ﻓﻬﺮﺳﺖﺷﺪﻩﺍﻧﺪ،
ﺷﯿﺮ ﺍﻧﺒﺴﺎﻁ
ﺑﺮﺭﺳﯽ ﮐﺮﺩ .ﺩﺭ ﺗﻤﺎﻡ ﻣﻮﺍﺭﺩ ،ﺁﺏ ﺳﺮﺩ ﻣﯽﺗﻮﺍﻧﺪ ﺑﺮﺍﯼ ﺧﻨﮏ ﮐﺮﺩﻥ ﻓﻀﺎ ﻭ ﺍﻫﺪﺍﻑ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺍﺳﺘﻔﺎﺩﻩ ﺷﻮﺩ.
ﺍﻭﺍﭘﺮﺍﺗﻮﺭ
ﻫﺘﻞﻫﺎ ،ﻣﺘﻞﻫﺎ ،ﭘﻨﺎﻫﮕﺎﻩﻫﺎ :ﺁﺏ ﮔﺮﻡ ﺑﺮﺍﯼ ﺍﻫﺪﺍﻑ ﺁﺷﺎﻣﯿﺪﻧﯽ ﮐﻤﭙﺮﺳﻮﺭ
ﻭ ﻏﯿﺮﺁﺷﺎﻣﯿﺪﻧﯽ ﻣﺎﻧﻨﺪ ﻟﺒﺎﺱﺷﻮﯾﯽ ،ﺁﺷﭙﺰﺧﺎﻧﻪ ،ﺣﻤﺎﻡ ﻭ ﮔﺮﻣﺎﯾﺶ ﺍﺳﺘﺨﺮ ﺷﻨﺎ
ﺳﯿﺴﺘﻢ ﺁﺏ ﺧﻨﮏ
ﺍﻣﮑﺎﻧﺎﺕ ﻭﺭﺯﺷﯽ )ﮐﺎﻟﺞ ،ﺩﺑﯿﺮﺳﺘﺎﻥ ،ﻋﻤﻮﻣﯽ( :ﺁﺏ ﮔﺮﻡ ﺑﺮﺍﯼ
ﮔــﺮﻡ ﺧﺮﻭﺟﯽ ،ﺗﺎﺑﻌﯽ ﺍﺯ ﺩﻣﺎﯼ ﺁﺏ ﮔﺮﻡ ﻭﺭﻭﺩﯼ ،ﺟﺮﯾﺎﻥ ﺁﺏ ﮔﺮﻡ ﻭ ﻇﺮﻓﯿﺖ ﭼﯿﻠﺮ ﺍﺳﺖ.
ﺩﻭﺵﻫﺎ ﻭ ﻏﺬﺍﺧﻮﺭﯼ ﻟﺒﺎﺱﺷﻮﯾﯽﻫﺎﯼ ﺗﺠﺎﺭﯼ :ﺁﺏ ﮔﺮﻡ ﻣﺼﺮﻓﯽ ﺑﯿﻤﺎﺭﺳـﺘﺎﻥﻫﺎ ﻭ ﻣﺮﺍﮐﺰ ﮐﻤﮏﻫﺎﯼ ﺍﻭﻟﯿـﻪ :ﺁﺏ ﮔﺮﻡ ﻣﻮﺭﺩ ﻧﯿﺎﺯ ﺑﺮﺍﯼ ﻟﺒﺎﺱﺷﻮﯾﯽ ،ﺗﺠﻬﯿﺰﺍﺕ ﺁﺷﭙﺰﺧﺎﻧﻪ ﻭ ﺍﺗﺎﻕ ﺍﻧﺘﻈﺎﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﻣﺴﮑﻮﻧﯽ ﻭ ﺍﺷﺘﺮﺍﮐﯽ :ﺁﺏ ﮔﺮﻡ ﺑﺮﺍﯼ ﺩﻭﺵﻫﺎ،
ﻣﻼﺣﻈﺎﺕ ﮐﺎﺭﺑﺮﺩﯼ
ﻟﺒﺎﺱﺷﻮﯾﯽ ،ﺁﺷﭙﺰﺧﺎﻧﻪ ﻭ ﻏﺬﺍﺧﻮﺭﯼ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ ﻣﯽﺗﻮﺍﻧﺪ ﺗﺎ 100%ﺣﺮﺍﺭﺕ ﭼﯿﻠﺮ ﺭﺍ ﺍﺯ ﭼﺮﺧﻪ ﺁﺏ ﮔﺮﻡ ﺗﺎﻣﯿﻦ ﮐﻨﺪ .ﺑﺎﯾﺪ ﺩﻣﺎﯼ ﺁﺏ ﺧﺮﻭﺟﯽ ﺩﺭ ﺷﺮﺍﯾﻂ ﺛﺎﺑﺖ ﺟﺮﯾــﺎﻥ ﺁﺏ ﮔﺮﻡ ،ﺑﻪ ﺣﺪﺍﮐﺜﺮ 131ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺮﺳــﺪ .ﻣﻘﺪﺍﺭ
ﻛﺎﺭﺑﺮﺩﻫﺎﯼ ﺧﺎﺹ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻭ ﻣﺎﻧﻨﺪ ﯾﮏ ﭼﯿﻠﺮ ﻫﻮﺍﯾــﯽ ﻣﻌﻤﻮﻟﯽ ﻋﻤﻞ ﺧﻮﺍﻫﺪ ﮐﺮﺩ .ﺩﻣﺎﯼ ﺁﺏ
ﺳﺎﻟﻦﻫﺎﯼ ﺍﻗﺎﻣﺘﯽ ﮐﺎﻟﺞ :ﺁﺏ ﮔﺮﻡ ﺑﺮﺍﯼ ﻟﺒﺎﺱﺷﻮﯾﯽ ،ﺁﺷﭙﺰﺧﺎﻧﻪ،
ﮐﻮﯾﻞﻫﺎﯼ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ
ﻣﺎﯾﻊ ﺧﻨﮏﺷــﺪﻩ ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ ،ﮐﻨﺘﺮﻝ ﻓﺸــﺎﺭ ﺍﺻﻠﯽ ﺑﺮﺍﯼ
ﺑﺮﺍﯼ ﺍﯾﻦ ﻣﺤﺪﻭﺩﯾﺖ ﻗﺎﯾﻞ ﻣﯽﺷﻮﺩ ﮐﻪ ﯾﮑﯽ ﺍﺯ ﺁﻥﻫﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺍﻃﻤﯿﻨــﺎﻥ ﺍﺯ ﻋﻤﻠﮑﺮﺩ ﭘﺎﯾﺪﺍﺭ ﭼﯿﻠﺮ ،ﻭﻗﺘــﯽ ﺩﻣﺎﯼ ﺁﺏ ﻭﺭﻭﺩﯼ ﺑﯿﻦ
ﺍﺯ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺁﺏ ﺳــﺮﺩ ﺍﺳــﺖ » :ﺩﺭﺻﻮﺭﺗﯽ ﮐﻪ ﺣﺪﺍﻗﻞ 75%
59ﻭ 104ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺍﺳــﺖ ،ﺿﺮﻭﺭﯼ ﺍﺳــﺖ .ﻭﻗﺘﯽ ﺩﻣﺎﯼ ﺁﺏ ﻭﺭﻭﺩﯼ ﺩﺭ ﻣﺤﺪﻭﺩﻩ ﺑﺎﺷﺪ ،ﺷﯿﺮ ﮐﻨﺘﺮﻟﯽ ﺑﺎ ﺳﻪﻣﺴﯿﺮ ﺍﺳﺘﻔﺎﺩﻩ
ﺷﯿﺮﯼ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ
ﻣﯽﺷﻮﺩ .ﻃﺮﺡ ﻟﻮﻟﻪﮐﺸﯽ ﺍﯾﻦ ﮐﺎﺭﺑﺮﺩﻫﺎ ﺩﺭ ﺗﺼﻮﯾﺮ ) (5ﻧﺸﺎﻥ ﺩﺍﺩﻩ
ﺁﺏ ﻣﺨﻠﻮﻁﺷﺪﻩ ﺑﻪ ﺳﻤﺖ ﺁﺏﮔﺮﻡﮐﻦ
ﺷﺪﻩ ﺍﺳﺖ.
ﺗﻠﻔﻦ55401278 :
ﺍﺳــﺖ .ﺑﻪ ﺩﻟﯿﻞ ﺁﻥﮐﻪ ﭼﺮﺧﻪ ﺁﺏ ﮔﺮﻡ ﺑﺮﺍﯼ ﺗﺮﺍﮐﻢ ﺳﺮﻣﺎﯾﺸــﯽ ﺩﺭ
ﺳــﺮﻣﺎﯾﺶ ﻣﺸﺎﺑﻪ ﺗﺼﺮﯾﺢ ﺩﺍﺭﺩ .ﺍﻟﺒﺘﻪ ﺍﯾﻦ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ،ﺍﺳﺘﺜﻨﺎﻫﺎﯾﯽ
ﺑﻪ ﺩﻟﯿﻞ ﺁﻥﮐﻪ ﺷﯿﺮ ﺳﻪﻣﺴﯿﺮﻩ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﭼﯿﻠﺮ، ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺗــﺎ ﺯﻣﺎﻥ ﮐﺎﻓﯽ ﺑﺮﺍﯼ ﻋﻤﻞ ﭘﺎﯾﺪﺍﺭ ﭼﯿﻠــﺮ ﻓﺮﺍﻫﻢ ﺁﯾﺪ .ﺩﺭﻧﺘﯿﺠﻪ ﺍﯾﻦ
ﺁﺏ ﺳﺮﺩ ﭘﻤﭗﻫﺎﯼ ﭼﺮﺧﺸﯽ ﺑﺎ ﺳﺮﻋﺖ ﺛﺎﺑﺖ
ﻓﺎﺻﻠﻪ ﻭ ﺣﺪﺍﻗﻞ ﺣﺠﻢ ﭼﺮﺧﻪ ﺑﺎﯾﺪ ﺑﺎ ﺍﻟﺰﺍﻣﺎﺕ ﺳﺎﺯﻧﺪﻩ ﺗﻄﺒﯿﻖ ﺩﺍﺩﻩ
ﺗﺼﻮﯾﺮ ) (5ﺷﯿﺮﯼ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ
ﺷﻮﻧﺪ. ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺩﻣﺎﯼ ﻣﺠــﺎﺯ ﺁﺏ ﮔﺮﻡ ﺧﺮﻭﺟﯽ ﺑﯿﻦ 68ﺗــﺎ 131ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ
ASHRAE 90.1 - 2007ﺑــﺮ ﻣﻤﻨﻮﻋﯿــﺖ ﮔﺮﻣﺎﯾــﺶ ﻭ
ﺿﺮﻭﺭﯼ ﺍﺳﺖ ،ﻓﺎﺻﻠﻪ ﺑﯿﻦ ﺍﯾﻦ ﺷﯿﺮ ﻭ ﭼﯿﻠﺮ ﺑﺎﯾﺪ ﺑﻪ ﺣﺪﺍﻗﻞ ﺑﺮﺳﺪ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺗﺼﻮﯾﺮ ) (4ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﺑﺎ ﻗﺎﺑﻠﯿﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﺣﺎﻟﺖ ﺑﺎﺯﯾﺎﺑﯽ ﮔﺮﻣﺎﯾﯽ
ﺍﺳﺘﺨﺮﻫﺎﯼ ﺷﻨﺎ ،ﺣﻤﺎﻡ ﻭ ﺩﻭﺵ
ﺻﻔﺤﻪ / 28ﺷﻤﺎﺭﻩ 30
ﺍﻧﺮﮊﯼ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﯾﺎ ﺗﺎﻣﯿﻦ ﻫﻮﺍﯼ ﮔﺮﻡ ﺩﺭ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﻣﺨﺘﻠﻂ ﺍﺯ
ﻗﻮﺍﻧﯿﻦ ﻣﺤﻠﯽ ﺑﻪ ﻣﺴﻮﻭﻟﯿﺖﭘﺬﯾﺮﯼ ﻃﺮﺍﺣﯽ ﺗﺨﺼﺼﯽ ﺑﺮﻣﯽﮔﺮﺩﺩ.
ﻣﻨﺒﻊ ﺑﺎﺯﯾﺎﻓﺖ ﺍﻧﺮﮊﯼ ﺗﺎﻣﯿﻦ ﺷــﻮﺩ ،ﺷــﺎﻣﻞ ﮔﺮﻣﺎﯾﺶ ﮐﻨﺪﺍﻧﺴﻮﺭ ﯾﺎ
ﻗــﺮﺍﺭﺩﺍﺩﻥ ﺩﯾﻮﺍﺭﻩﺍﯼ ﺩﻭﺟــﺪﺍﺭﻩ ﻭ ﺩﺍﺭﺍﯼ ﺗﻬﻮﯾــﻪ ﺑﺮﺍﯼ ﻣﺒﺪﻝ
ﻣﻨﺒﻊ ﺍﻧﺮﮊﯼ ﺧﻮﺭﺷــﯿﺪﯼ« .ﺑﻪ ﻫﻤﯿﻦ ﺩﻟﯿﻞ ﮐﺎﻣﻼ ﺍﻣﮑﺎﻥ ﻃﺮﺍﺣﯽ
ﺣﺮﺍﺭﺗﯽ ،ﺭﺍﻫﯽ ﺑﺮﺍﯼ ﻣﻮﺍﺟﻪ ﺷــﺪﻥ ﺑﺎ ﭼﻨﯿﻦ ﻗﺎﻧﻮﻧﯽ ﺍﺳــﺖ .ﺍﯾﻦ
ﺳﯿﺴــﺘﻢ ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾﺸــﯽ ﺑﺮﺍﯼ ﺣﺪﺍﻗﻞ 75%ﯾــﺎ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﺩﺭ
ﻣﺒﺪﻝﻫــﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑــﺮ ﺑﺮﺧﯽ ﭼﯿﻠﺮﻫﺎﯼ ﺍﺣﯿــﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻭﺟﻮﺩ
ﻋﯿﻦ ﻣﻄﺎﺑﻘﺖ ﺑﺎ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻭﺟﻮﺩ ﺩﺍﺭﺩ .ﻫﻤﭽﻨﯿﻦ ﺩﻣﺎﯼ ﺁﺏ ﮔﺮﻡ
ﺩﺍﺭﻧﺪ.
ﺧﺮﻭﺟﯽ ﺑﻪﺩﺳﺖﺁﻣﺪﻩ ﺍﺯ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﻣﺘﻨﺎﺳﺐ ﺑﺎ ﻗﺎﺑﻠﯿﺖﻫﺎﯼ ﻋﻤﻠﮑﺮﺩ ﮐﻮﯾﻞ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﺍﺳﺖ.
ﺍﻟﺒﺘﻪ ﺭﻭﺵ ﺩﯾﮕﺮﯼ ﻧﯿﺰ ﻭﺟﻮﺩ ﺩﺍﺭﺩ ﮐﻪ ﺳــﯿﺎﻻﺕ ﻣﻨﺘﻘﻞﮐﻨﻨﺪﻩ ﺣﺮﺍﺭﺕ ﺭﺍ ﺍﺯ ﻣﻨﺒﻊ ﺁﺏ ﺁﺷــﺎﻣﯿﺪﻧﯽ ﺟﺪﺍ ﻣﯽﮐﻨﺪ ﻭ ﺁﻥ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ
ﺩﺭ ﺑﺮﺧــﯽ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﺣﺠــﻢ ﻣﺘﻐﯿﺮﯼ ﺍﺯ ﻫﻮﺍ ،ﺁﺏ ﮔﺮﻡ 105ﺗﺎ 131ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺭﺍ ﻣﯽﺗﻮﺍﻥ ﺑﻪ ﻃﻮﺭ ﺑﺴﯿﺎﺭ ﻣﻮﺛﺮﯼ
ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﻌﻤﻮﻟﯽ ﺍﺳــﺖ ﮐﻪ ﺑﯿﻦ ﻣﻨﺒﻊ ﺁﺏ ﺁﺷﺎﻣﯿﺪﻧﯽ ﻭ ﺁﺏ ﮔﺮﻡ ﺍﺣﯿﺎ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ )ﺗﺼﻮﯾﺮ .(7
ﺑﻪ ﻭﺳــﯿﻠﻪ ﻗﺮﺍﺭﺩﺍﺩﻥ ﺩﻭ ﺭﺩﯾﻒ ﮐﻮﯾﻞ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﺑﻪﺟﺎﯼ ﯾﮏ ﺭﺩﯾﻒ ﺑﺎ ﻃﺮﺍﺣﯽ ﻣﻨﺎﺳــﺐ ﺗﺮﺍﮐﻢ ﺑﻪ ﻣﻘﺪﺍﺭ ﻣﻨﺎﺳــﺐ ﺍﻧــﺮﮊﯼ ﺑﺎﺯﯾﺎﻓﺘﯽ،
ﺑــﺮ ﺍﺳــﺎﺱ ﺑﺮﺧﯽ ﻗﻮﺍﻧﯿــﻦ ،ﺩﻣﺎﯼ ﭼﺸــﻤﻪﻫﺎﯼ ﺁﺏ ﻣﻌﺪﻧﯽ
ﺍﻣﮑﺎﻥﭘﺬﯾﺮ ﺍﺳــﺖ .ﺍﮔﺮ ﻧﯿﺎﺯ ﺑﻪ ﺁﺏ ﮔﺮﻣﯽ ﺑﺎ ﺩﻣﺎﯼ ﺑﯿﺸــﺘﺮ ﺩﺍﺷﺘﻪ
ﺑﺎﯾــﺪ ﺗــﺎ 104ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﻣﺤﺪﻭﺩ ﺷــﺪﻩ ﻭ ﺩﻣﺎﯼ ﺩﻟﺨﻮﺍﻩ ﺩﺭ
ﺑﺎﺷــﯿﻢ ،ﻣﯽﺗﻮﺍﻥ ﺍﺑﺰﺍﺭ ﮔﺮﻣﺎﯾﯽ ﮐﻤﮑﯽ ﻣﺎﻧﻨــﺪ ﺑﻮﯾﻠﺮ ﺁﺏ ﮔﺮﻡ ﺭﺍ ﺑﻪ
ﺍﺳــﺘﺨﺮﻫﺎﯼ ﺷﻨﺎ 80 ،ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺍﺳﺖ .ﺍﯾﻦ ﺩﻣﺎﻫﺎ ﺑﻪﺧﻮﺑﯽ
ﭼﺮﺧﻪ ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾﺶ ﺍﻓﺰﻭﺩ )ﺗﺼﻮﯾﺮ .(6
ﺩﺭ ﻣﺤﺪﻭﺩﻩ ﻋﻤﻠﮑﺮﺩ ﺳﯿﺴﺘﻢﻫﺎﯾﯽ ﺑﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻫﺴﺘﻨﺪ .ﯾﮑﯽ ﺍﺯ ﭼﺎﻟﺶﻫﺎﯼ ﻃﺮﺍﺣﯽ ﺩﺭ ﺍﯾﻦ ﺯﻣﯿﻨﻪ ،ﻣﺤﺎﻓﻈﺖ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ
ﺁﺏ ﮔﺮﻡ ﺁﺷﺎﻣﯿﺪﻧﯽ ﺩﺭ ﻣﻨﺎﺯﻝ
ﺣﺮﺍﺭﺗﯽ ﺍﺯ ﺗﺎﺛﯿﺮﺍﺕ ﻓﺮﺳﺎﯾﺸــﯽ ﺁﺏ ﭼﺸــﻤﻪﻫﺎﯼ ﻣﻌﺪﻧﯽ ﯾﺎ ﺍﺳﺘﺨﺮ
ﻣــﯽ ﺗــﻮﺍﻥ ﺍﺯ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺕ ﺑــﺮﺍﯼ ﭘﯿﺶﮔﺮﻣﺎﯾــﺶ ﺁﺏ ﮔﺮﻡ ﺁﺷــﺎﻣﯿﺪﻧﯽ ﺩﺭ ﻣﻨﺎﺯﻝ ﺑﻬﺮﻩ ﺑﺮﺩ؛ ﺍﻟﺒﺘﻪ ﺑﺮﺧﯽ ﻗﻮﺍﻧﯿﻦ ﺳﺎﺧﺘﻤﺎﻧﯽ، ﻣﺤﺎﻓﻈﺖ ﻣﻨﺒﻊ ﺁﺏ ﺁﺷــﺎﻣﯿﺪﻧﯽ ﺭﺍ ﺩﺭﺑﺮﺍﺑﺮ ﻭﺟﻮﺩ ﺳﯿﺎﻻﺕ ﺍﻧﺘﻘﺎﻝ ﺣﺮﺍﺭﺕ ﺳﻤﯽ ،ﺍﻟﺰﺍﻣﯽ ﻣﯽﺩﺍﻧﻨﺪ .ﺑﺮﺍﯼ ﻣﺜﺎﻝ ،ﻗﺎﻧﻮﻥ ﻟﻮﻟﻪﮐﺸﯽ ﺩﺭ ﺍﯾﺎﻟﺖ ﻧﯿﻮﯾﻮﺭﮎ ﺑﯿﺎﻥ ﻣﯽﮐﻨﺪ ﮐﻪ »ﻣﺒﺪﻝﻫﺎﯼ ﺣﺮﺍﺭﺗﯽ ﮐﻪ ﺍﺯ ﺳﯿﺎﻝ ﺍﻧﺘﻘﺎﻝﺩﻫﻨﺪﻩ ﺳﻤﯽ ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﮐﻨﻨﺪ ،ﺑﺎﯾﺪ ﺍﺯ ﺁﺏ ﺁﺷﺎﻣﯿﺪﻧﯽ ﺑﺎ
ﺍﺳــﺖ .ﻏﻠﻈﺖ ﺑــﺎﻻﯼ ﺿﺪﻋﻔﻮﻧﯽﮐﻨﻨﺪﻩﻫﺎﯼ ﮐﻠﺮ ،ﺑــﺮﻡ ﻭ ﮐﻠﺮﯾﺪ ﺳــﺪﯾﻢ ،ﺑﺎﻋﺚ ﻓﺮﺳــﺎﯾﺶ ﺍﺟﺰﺍﯼ ﻓﻠﺰﯼ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻣﯽﺷــﻮﺩ .ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﻌﻤﻮﻝ ﺑﺎ ﺳــﺎﺧﺘﺎﺭ ﻣﻘﺎﻭﻡ ﺩﺭﺑﺮﺍﺑﺮ ﻓﺮﺳﺎﯾﺶ ،ﺑﻪ ﺍﯾﻦ ﻣﺸﮑﻞ ﮐﻤﮏ ﻣﯽﮐﻨﺪ )ﺗﺼﻮﯾﺮ .(8
ﮔﺮﻡ ﮐﺮﺩﻥ ﺁﺏ ﻟﺒﺎﺱﺷﻮﯾﯽ
ﺩﯾﻮﺍﺭﻩﺍﯼ ﺩﻭﺟﺪﺍﺭﻩ ﺟﺪﺍ ﺷﻮﻧﺪ .ﺩﺭ ﺑﯿﻦ ﺩﻭ ﺩﯾﻮﺍﺭﻩ ﺑﺎﯾﺪ ﻻﯾﻪ ﻫﻮﺍﯾﯽ
ﻟﺒﺎﺱﺷﻮﯾﯽﻫﺎﯼ ﺗﺠﺎﺭﯼ ﮐﻪ ﺑﻪ ﻋﻨﻮﺍﻥ ﻟﺒﺎﺱﺷﻮﯾﯽﻫﺎﯼ ﺻﻨﻌﺘﯽ
ﻭﺟﻮﺩ ﺩﺍﺷــﺘﻪ ﺑﺎﺷــﺪ ﮐﻪ ﺑﻪ ﻓﻀﺎﯼ ﻣﺤﯿﻂ ﺑﺎﺯ ﺷﻮﺩ« .ﺗﻄﺒﯿﻖ ﺑﺎ
ﻧﯿﺰ ﺷــﻨﺎﺧﺘﻪ ﻣﯽﺷــﻮﻧﺪ ،ﺍﺯ ﻣﻘﺎﺩﯾﺮ ﺯﯾﺎﺩﯼ ﺁﺏ ﺑﺮﺍﯼ ﺷﺴﺖﻭﺷﻮ ﻭ
ﻭﺍﺣﺪ ﮔﺮﻣﺎﯾﺶ ﮐﻤﮑﯽ )ﺑﻮﯾﻠﺮ(
ﺗﻠﻔﻦ88739880-2:
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﮐﻮﯾﻞ ،ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﺩﺭ ﺍﯾﻦ ﮐﺎﺭﺑﺮﺩﻫﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺣﺮﺍﺭﺕ ﺍﺣﯿﺎﺷﺪﻩ
ﮔﺮﻣﺎﯾﺶ ﺩﺭ ﺍﺳﺘﺨﺮﻫﺎﯼ ﺷﻨﺎ ﻭ ﭼﺸﻤﻪﻫﺎﯼ ﺁﺏﻣﻌﺪﻧﯽ
ﺷﯿﺮﯼ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﻣﻨﺒﻊ ﺁﺏ ﻣﺤﻠﯽ
ﺑﻪ ﺳﻤﺖ ﺳﯿﺴﺘﻢ ﮐﻮﯾﻞ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ
ﺍﺯ ﺳﯿﺴﺘﻢ ﮐﻮﯾﻞ ﺑﺎﺯﮔﺮﻣﺎﯾﯽ ﭘﻤﭗﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺗﺼﻮﯾﺮ ) (6ﻭﺍﺣﺪ ﮔﺮﻣﺎﯾﺶ ﮐﻤﮑﯽ ﺑﻪ ﺩﻣﺎﯼ ﺁﺏ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯿﺎﻧﯽ ﻣﺨﺰﻥ ﺫﺧﯿﺮﻩ
ﺁﺏ ﻣﺨﻠﻮﻁﺷﺪﻩ ﺑﻪ ﺳﻤﺖ ﺁﺏﮔﺮﻡﮐﻦ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﭘﻤﭗﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﭘﻤﭗﻫﺎﯼ ﭼﺮﺧﺸﯽ
ﺗﺼﻮﯾﺮ ) (7ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯿﺎﻧﯽ ﺑﯿﻦ ﺁﺏ ﺁﺷﺎﻣﯿﺪﻧﯽ ﻭ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 29ﺷﻤﺎﺭﻩ 30
ﺁﺏﮐﺸﯽ ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ .ﻣﺮﺍﮐﺰ ﺯﯾﺎﺩﯼ ﻭﺟﻮﺩ ﺩﺍﺭﻧﺪ ﮐﻪ ﺍﺯ ﺍﯾﻦ ﺷﯿﻮﻩ
ﺁﺏ ﺳﺮﺩ ﻭﺭﻭﺩﯼ
ﺍﺳﺘﺨﺮ ﯾﺎ ﭼﺸﻤﻪ ﻣﻌﺪﻧﯽ
ﻟﺒﺎﺱﺷــﻮﯾﯽ ﺑﻬﺮﻩ ﻣﯽﺑﺮﻧﺪ .ﻣﺎﻧﻨﺪ ﻫﺘﻞﻫﺎ ،ﻣﺘﻞﻫﺎ ،ﺩﺭﻣﺎﻧﮕﺎﻩﻫﺎ، ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯿﺎﻧﯽ
ﺯﻧﺪﺍﻥﻫﺎ ،ﺩﺍﻧﺸﮕﺎﻩﻫﺎ ﻭ ﺑﯿﻤﺎﺭﺳﺘﺎﻥﻫﺎ .ﭘﯿﺶﮔﺮﻣﺎﯾﺶ ﺁﺏ ﻣﺼﺮﻓﯽ ﺁﻥﻫﺎ ﺑﺎﻋﺚ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺯﯾﺎﺩﯼ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺧﻮﺍﻫﺪ ﺷﺪ. ﺗﻮﺟـﻪ :ﺑﺮﺧــﯽ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﻟﺒﺎﺱﺷــﻮﯾﯽ ،ﺧــﻮﺩ ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾﯽ ﺩﺍﺷــﺘﻪ ﻭ ﺁﺏ ﻣﺼﺮﻓﯽ ﺑﻪ ﺣﺪ ﮐﺎﻓﯽ ﮔﺮﻡ ﻣﯽﺷﻮﺩ ﺗﺎ ﺑﺎﻋﺚ ﭘﯿﺶﮔﺮﻣﺎﯾﯽ ﺁﺏ ﺷــﻮﺩ .ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﻭﻗﺘﯽ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﭘﻤﭗﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺳﯿﺴﺘﻢ ﻟﺒﺎﺱﺷﻮﯾﯽ ﺧﻮﺩ ﺳﯿﺴﺘﻢ ﺑﺎﺯﯾﺎﻓﺖ ﮔﺮﻣﺎﯾﯽ ﻣﺴﺘﻘﻠﯽ ﺩﺍﺭﺩ، ﻣﺤﺪﻭﺩ ﺧﻮﺍﻫﺪ ﺷﺪ. ﺑﺎﯾﺪ ﺍﺯ ﻣﻄﺎﺑﻘﺖ ﮐﺎﺭﺑﺮﺩ ﭼﯿﻠﺮ ﺩﺭ ﻋﻤﻠﯿﺎﺕ ﻣﻮﺭﺩ ﻧﻈﺮ ﺑﺎ ﺍﻟﺰﺍﻣﺎﺕ ﺳــﺎﺯﻧﺪﻩ ،ﻣﻄﻤﺌﻦ ﺷﺪ .ﭼﯿﻠﺮ ﻫﻮﺍﯾﯽ ﻣﺪﻝ 30RBﮐﺮﯾﺮ ﺑﺎ ﻗﺎﺑﻠﯿﺖ ﺍﺣﯿﺎ ،ﺩﺭ ﻋﻤﻠﮑﺮﺩ ﭘﯿﻮﺳــﺘﻪ 59ﺩﺭﺟــﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﻭ ﻭﻗﺘﯽ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﺍﺳﺘﻔﺎﺩﻩ ﺷﻮﺩ ،ﻣﺤﺪﻭﺩ ﻣﯽﺷﻮﺩ .ﺁﺏ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻟﻮﻟﻪ ﺍﺻﻠﯽ ﺁﺏ ﺷــﻬﺮﯼ ﯾﺎ ﺁﺏ ﭼﺎﻩ ﺑﺎ ﺩﻣﺎﯼ 50ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﯾﺎ ﺩﺭ ﺑﺮﺧﯽ ﺷــﺮﺍﯾﻂ ﺁﺏ ﻭ ﻫﻮﺍﯾﯽ ،ﮐﻤﺘﺮ ﺍﺯ ﺁﻥ ﺍﺳﺖ .ﺍﯾﻦ ﺩﻣﺎ ﺳﺮﺩﺗﺮ
ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺍﺣﯿﺎ ﻧﻪﻓﻘﻂ ﺑﺎﻋــﺚ ﻓﺮﺍﻫﻢ ﺁﻣﺪﻥ ﻣﻘــﺪﺍﺭ ﺯﯾﺎﺩﯼ ﮔﺮﻣﺎﯼ ﻣﻔﯿﺪ ﻣﯽﺷــﻮﺩ ،ﻧﻘﺶ ﻣﻬﻤﯽ ﻧﯿﺰ ﺩﺭ ﻓﺮﺁﯾﻨﺪ ﺳﺮﻣﺎﯾﺶ ﺍﯾﻔﺎ ﻣﯽﮐﻨﺪ .ﺩﻣﺎﯼ ﺁﺏ ﻭﺭﻭﺩﯼ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺑﺮ ﺳﯿﺴــﺘﻢ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﭼﯿﻠﺮ ،ﺗﺎﺛﯿﺮﮔﺬﺍﺭ ﺍﺳﺖ .ﺍﮔﺮ ﺍﯾﻦ ﺩﻣﺎ ﺧﯿﻠﯽ ﭘﺎﯾﯿﻦ ﺑﺎﺷﺪ ،ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﺳﯿﺴﺘﻢ ﺳﺮﻣﺎﯾﺶ ﺑﺮ ﻋﻤﻠﮑﺮﺩ ﭼﯿﻠﺮ ،ﺍﺛﺮ ﺧﻮﺍﻫﺪ ﮔﺬﺍﺷﺖ .ﺍﮔﺮ ﺩﻣﺎﯼ ﻭﺭﻭﺩﯼ ﺑﯿﻦ 59ﻭ 104ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺎﺷﺪ ،ﺑﺮﺍﯼ ﺗﺎﻣﯿﻦ ﻓﺸــﺎﺭ ﺍﺻﻠﯽ ﻣﻨﺎﺳــﺐ ،ﭼﯿﻠﺮ ﺑﺎﯾﺪ ﮐﻨﺘﺮﻝ ﺟﺮﯾﺎﻥ ﺁﺏ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺭﺍ ﺩﺭ ﺩﺳــﺖ ﮔﯿﺮﺩ .ﺷﯿﺮ ﮐﻨﺘﺮﻟﯽ ﺑﺎ ﺳﻪ ﻣﺴــﯿﺮ ﻣﻄﺎﺑﻖ ﺗﺼﻮﯾﺮ )،(9
ﻭﺭﻭﺩﯼ ﺗﺎ ﺯﯾﺮ 59ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺍﺳــﺖ .ﺑﺎ ﺷﺮﻭﻉ ﺑﻪ ﮐﺎﺭ ﺳﯿﺴﺘﻢ ﺫﻭﺏ ﺑﺮﻑﻫﺎ ،ﺩﻣﺎﯼ ﺳــﯿﺎﻝ ﻣﻤﮑﻦ ﺍﺳــﺖ ﺑﻪ ﺯﯾــﺮ ﺍﯾﻦ ﻣﺤﺪﻭﺩﻩ ﺑﺮﺳﺪ .ﺩﺭﻧﺘﯿﺠﻪ ﮐﻨﺘﺮﻝ ﺩﻣﺎﯼ ﺳﯿﺎﻝ ﺫﻭﺏ ﺑﺮﻑﻫﺎ ﺑﺮﺍﯼ ﺍﻃﻤﯿﻨﺎﻥ ﺍﺯ ﻗﺮﺍﺭ ﮔﺮﻓﺘﻦ ﺩﻣﺎﯼ ﺁﺏ ﻭﺭﻭﺩﯼ ﺩﺭ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ ﭼﯿﻠﺮ ،ﺿﺮﻭﺭﯼ ﺍﺳﺖ .ﺷﯿﺮ ﺳﻪﻣﺴﯿﺮﻩ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﮐﻪ ﺩﺭ ﺑﺎﻻ ﻣﻄﺮﺡ ﺷﺪ، ﻭﻗﺘﯽ ﺩﻣﺎﯼ ﻭﺭﻭﺩﯼ ﺑﻪ ﺯﯾﺮ 59ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺮﺳــﺪ ،ﺍﺳــﺘﻔﺎﺩﻩ ﻗﺮﺍﺭ ﺷﺪ )ﺗﺼﻮﯾﺮ .(9 ﺑﺮﺍﯼ ﺳﯿﺴــﺘﻤﯽ ﮐﻪ ﺩﺭ ﺷــﺮﺍﯾﻂ ﺳــﺮﺩ ﺑﯿﺮﻭﻥ ﻗﺮﺍﺭ ﺩﺍﺭﺩ ،ﺩﺭ ﻣــﻮﺍﺭﺩﯼ ﮐﻪ ﺩﻣﺎﯼ ﺳــﯿﺎﻝ ﻣﻤﮑﻦ ﺍﺳــﺖ ﺑﻪ ﮐﻤﺘــﺮ ﺍﺯ 32ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺮﺳﺪ ،ﺑﺎﯾﺪ ﺍﺯ ﻣﺤﻠﻮﻝ ﺿﺪﯾﺦ ﻣﻨﺎﺳﺐ ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ. ﺩﺭ ﺁﺏ ﻭ ﻫﻮﺍﯼ ﺳﺮﺩﺗﺮ ،ﺩﻣﺎﯼ ﺯﻣﯿﻦ ﺩﺭ ﺯﻣﺴﺘﺎﻥ ﻣﻤﮑﻦ ﺍﺳﺖ ﺑﻪ ﮐﻤﺘﺮ ﺍﺯ 59ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺮﺳــﺪ ﮐﻪ ﮐﻤﺘﺮ ﺍﺯ ﻣﺤﺪﻭﺩﻩ ﻋﻤﻞ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻣﺤﺪﻭﺩﯾﺖﻫﺎﯾﯽ ﺑﻪ ﻭﺟﻮﺩ ﻣﯽﺁﻭﺭﺩ.
ﺗﺼﻮﯾﺮ ) (8ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯿﺎﻧﯽ ﺑﯿﻦ ﭼﺸﻤﻪ ﺁﺏ ﻣﻌﺪﻧﯽ / ﺍﺳﺘﺨﺮ ﻭ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺍﺯ ﺣﺪﺍﻗــﻞ ﺩﻣﺎﯼ ﻭﺭﻭﺩﯼ ﺁﺏ ﺑﻮﺩﻩ ﻭ ﺑــﺮﺍﯼ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﭘﻤﭗﻫﺎﯼ ﭼﺮﺧﺸﯽ
ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﺳــﺖ .ﺩﺭ ﺍﯾﻦ ﺷﺮﺍﯾﻂ ﺑﺎﯾﺪ ﺍﺯ ﻭﺍﺣﺪ ﮔﺮﻣﺎﯾﺶ ﮐﻤﮑــﯽ ﻣﺎﻧﻨﺪ ﺑﻮﯾﻠﺮ ﺑﺮﺍﯼ ﺭﺳــﯿﺪﻥ ﺑﻪ ﻣﺤــﺪﻭﺩﻩ ﻋﻤﻠﮑﺮﺩ ﻣﺠﺎﺯ،
ﺍﺳــﺘﻔﺎﺩﻩ ﻣﯽﺷــﻮﺩ .ﻭﻗﺘﯽ ﺩﻣﺎﯼ ﻭﺭﻭﺩﯼ ﺑﯿــﻦ 59ﻭ 104ﺩﺭﺟﻪ ﮐﻨﺘﺮﻝ ﺁﻧﺎﻟﻮﮒ ﺑﻪ ﺷــﯿﺮ ﺳــﻪﺭﺍﻫﻪﺍﯼ ﻣﯽﻓﺮﺳــﺘﺪ ﮐﻪ ﺑﺮﺍﯼ ﺗﻨﻈﯿﻢ ﺟﺮﯾﺎﻥ ﺁﺏ ﮐﻨﺪﺍﻧﺴــﻮﺭ ﺑﯿﻦ 20ﺗﺎ ،100ﺑﺎﺯ ﺷــﺪﻩ ﻭ ﻓﺸــﺎﺭ ﺍﺻﻠﯽ ﻣﻨﺎﺳــﺐ ﺭﺍ ﺗﺎﻣﯿﻦ ﻣﯽﮐﻨﺪ .ﺷــﯿﺮ ﺩﺭ ﻫﯿﭻ ﺯﻣﺎﻧﯽ ﺍﻣﮑﺎﻥ ﺟﺮﯾﺎﻧﯽ ﮐﻤﺘﺮ ﺍﺯ 20%ﺟﺮﯾﺎﻥ ﮐﺎﻣﻞ ﺭﺍ ﻧﺨﻮﺍﻫﺪ ﺩﺍﺩ.
ﺁﺏ ﻣﺨﻠﻮﻁﺷﺪﻩ ﺑﻪ ﺳﻤﺖ ﺁﺏﮔﺮﻡﮐﻦ
ﺫﻭﺏ ﺑﺮﻑﻫﺎ ﺩﺭ ﺁﺏﻭﻫﻮﺍﯼ ﺳــﺮﺩ ﻭ ﺑﺎﺭﺵ ﺑﺮﻑ ﮐﻢ ﺗﺎ ﻣﺘﻮﺳﻂ ،ﻓﺮﺁﯾﻨﺪﻫﺎﯼ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺳــﺎﺧﺘﻤﺎﻧﯽ ﮐﻪ ﺩﺭ ﻃﻮﻝ ﺳــﺎﻝ ﻧﯿﺎﺯﻣﻨﺪ ﺁﺏ ﺳــﺮﺩ ﺑﺮﺍﯼ ﺍﻫﺪﺍﻑ
ﺑﺒﺮﻧﺪ .ﺑﺰﺭﮒﺗﺮﯾﻦ ﭼﺎﻟﺶ ﭘﯿﺶ ﺭﻭﯼ ﺍﯾﻦ ﮐﺎﺭﺑﺮﺩ ،ﮐﺎﻫﺶ ﺩﻣﺎﯼ ﺁﺏ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻣﺨﺰﻥ ﺫﺧﯿﺮﻩ
ﭘﻤﭗﻫﺎﯼ ﭼﺮﺧﺸﯽ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺎ ﺳﺮﻋﺖ ﺛﺎﺑﺖ
ﺳﺮﻣﺎﯾﺸﯽ ﻫﺴــﺘﻨﺪ ،ﻣﯽﺗﻮﺍﻧﻨﺪ ﺍﺯ ﻣﺰﯾﺖ ﺗﻮﻟﯿﺪ ﺁﺏ ﮔﺮﻡ ﺑﻪ ﻭﺳﯿﻠﻪ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻭ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺁﻥ ﺑــﺮﺍﯼ ﺫﻭﺏ ﺑﺮﻑﻫﺎ ،ﺑﻬﺮﻩ
ﺗﻠﻔﻦ55401278 :
ﺳﯿﮕﻨﺎﻝ ﮐﻨﺘﺮﻝ Vdc 10 - 0
ﺷﯿﺮﯼ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ
ﺗﺼﻮﯾﺮ ) (9ﻭﺭﻭﺩ ﺁﺏ ﺑﻪ ﺳﯿﺴﺘﻢ ﺑﺎ ﺷﯿﺮﯼ ﺩﺍﺭﺍﯼ ﺳﻪ ﻣﺴﯿﺮ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺎﺷــﺪ ،ﺳﯿﺴﺘﻢ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﭼﯿﻠﺮ ﯾﮏ ﺳﯿﮕﻨﺎﻝ
ﻣﻨﺒﻊ ﺁﺏ ﺳﺮﺩ ﻭﺭﻭﺩﯼ
ﺻﻔﺤﻪ / 30ﺷﻤﺎﺭﻩ 30
ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﺗﺼﻮﯾﺮ ) (10ﻧﺸﺎﻥﺩﻫﻨﺪﻩ ﻣﻮﻗﻌﯿﺖ ﻭﺍﺣﺪ ﮔﺮﻣﺎﯾﺶ ﺷﯿﺮﯼ ﺑﺎ ﺳﻪ ﻣﺴﯿﺮ ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ
ﮐﻤﮑﯽ ﺑﺮﺍﯼ ﺍﻃﻤﯿﻨﺎﻥ ﺍﺯ ﺩﻣﺎﯼ ﻣﻨﺎﺳــﺐ ﻭﺭﻭﺩﯼ ﺁﺏ ﻭ ﻋﻤﻞ ﭼﯿﻠﺮ
ﺑﻪ ﺳﻤﺖ ﺳﯿﺴﺘﻢ ﺫﻭﺏ ﺑﺮﻑ
ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﺳﺖ.
ﻓﺮﺁﯾﻨﺪ ﮔﺮﻣﺎﯾﺶ ﻓﻬﻢ ﮐﺎﻣﻞ ﭼﺮﺧﻪ ﻭ ﺩﻣﺎﯼ ﻣﻮﺭﺩ ﻧﯿﺎﺯ ﺑﺮﺍﯼ ﻓﺮﺁﯾﻨﺪ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ
ﺍﺯ ﺳﯿﺴﺘﻢ ﺫﻭﺏ ﺑﺮﻑ
ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﭘﻤﭗﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺣﺮﺍﺭﺗﯽ ،ﺍﻫﻤﯿﺖ ﺯﯾﺎﺩﯼ ﺩﺍﺭﺩ .ﻓﺮﺁﯾﻨﺪ ﮔﺮﻣﺎﯾﺶ ﻣﻌﻤﻮﻻ ﺑﺮ ﺍﺳﺎﺱ ﮐﺎﺭﺑﺮﺩ ﺁﺏ ﻏﯿﺮﺁﺷﺎﻣﯿﺪﻧﯽ ﺍﺳﺖ؛ ﺍﻟﺒﺘﻪ ﺩﺭ ﺻﻮﺭﺗﯽ ﮐﻪ ﻓﺮﺁﯾﻨﺪ ﺑﺮﺍﯼ ﺍﻫﺪﺍﻑ ﺁﺷﺎﻣﯿﺪﻧﯽ ﺍﺳــﺘﻔﺎﺩﻩ ﺷﻮﺩ ،ﺑﺎﯾﺪ ﺩﻗﺖ ﻻﺯﻡ ﺑﻪ ﻋﻤﻞ ﺁﯾﺪ. ﺍﯾﻦ ﮐﺎﺭﺑﺮﺩ ﻧﯿﺎﺯﻣﻨﺪ ﺟﺪﺍﺳــﺎﺯﯼ ﺑﯿﻦ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻭ ﻣﻨﺒﻊ ﺁﺏ ﺁﺷﺎﻣﯿﺪﻧﯽ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯿﺎﻧﯽ ﺍﺳﺖ ﮐﻪ
ﻭﺍﺣﺪ ﮔﺮﻣﺎﯾﺶ ﮐﻤﮑﯽ
ﺩﺭ ﮔﺬﺷﺘﻪ ﺑﻪ ﺁﻥ ﺍﺷﺎﺭﻩ ﺷﺪ. ﻃﺒﯿﻌــﺖ ﭼﺮﺧــﻪﺍﯼ ﺑﺴــﯿﺎﺭﯼ ﺍﺯ ﻓﺮﺁﯾﻨﺪﻫــﺎﯼ ﮔﺮﻣﺎﯾﺸــﯽ، ﺩﺭﺻﻮﺭﺗﯽ ﮐﻪ ﺑﻪﺩﻗﺖ ﺻﻮﺭﺕ ﻧﮕﯿﺮﺩ ،ﺑﺎﻋﺚ ﭘﺪﯾﺪ ﺁﻣﺪﻥ ﭼﺎﻟﺸــﯽ
ﺗﺼﻮﯾﺮ ) (10ﻭﺍﺣﺪ ﮔﺮﻣﺎﯾﺶ ﮐﻤﮑﯽ ﺑﺮﺍﯼ ﺳﯿﺴﺘﻢ ﺫﻭﺏ ﺑﺮﻑﻫﺎ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺑﺮﺍﯼ ﻋﻤــﻞ ﭘﺎﯾﺪﺍﺭ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺧﻮﺍﻫﺪ ﺷــﺪ .ﺣﺠﻢ ﺩﺭ ﮔﺮﺩﺵ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﮐﻪ ﺑﻪ ﺻﻮﺭﺕ ﭼﻨﺪ ﮔﺎﻟﻮﻥ ﺳﯿﺎﻝ ﺍﺳﺖ ،ﺑﺎ
○ ﺑﻠﯽ
ﻧﻮﺳﺎﻧﺎﺕ ﻓﺮﺁﯾﻨﺪ ﮔﺮﻣﺎﯾﺸﯽ ﺍﻫﻤﯿﺖ ﺑﯿﺸﺘﺮﯼ ﻣﯽﯾﺎﺑﺪ .ﺑﺮﺍﯼ ﻣﻮﺍﺟﻪ
ﺁﯾﺎ ﺑﺎﺭ ﺁﺏ ﺳﺮﺩ ﺑﯿﻦ 60ﺗﺎ 190ﺗﻦ ﺍﺳﺖ؟
○ ﺧﯿﺮ
ﺷﺪﻥ ﺑﺎ ﺍﯾﻦ ﻧﻮﺳﺎﻧﺎﺕ ،ﺑﺎﯾﺪ ﺣﺪﺍﻗﻞ ﺣﺠﻢ ﺩﺭ ﮔﺮﺩﺵ ﮐﻪ ﺳﺎﺯﻧﺪﻩ
○ ﺑﻠﯽ
ﺗﻮﺻﯿﻪ ﮐﺮﺩﻩ ،ﻣﺪﻧﻈﺮ ﻗﺮﺍﺭ ﮔﯿﺮﺩ .ﻣﺨﺰﻥ ﺫﺧﯿﺮﻩ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ )(9
ﺁﯾــﺎ ﺑــﺎﺭ ﺁﺏ ﮔﺮﻡ ﺑﯿــﻦ 770ﻭ MBH 2650ﺍﺳــﺖ؟ )ﺑﺮﺍﯼ
ﻧﺸﺎﻥ ﺩﺍﺩﻩ ﺷﺪﻩ ،ﻣﯽﺗﻮﺍﻧﺪ ﺣﺠﻢ ﺩﺭ ﮔﺮﺩﺵ ﻣﻮﺛﺮﯼ ﺭﺍ ﺑﻪ ﺳﯿﺴﺘﻢ
○ ﺧﯿﺮ
ﮐﺎﺭﺑﺮﺩﻫﺎﯾﯽ ﺑﺎ ﭼﯿﻠﺮ ﺗﮏ(
ﺍﻓﺰﻭﺩﻩ ﻭ ﺑﻪ ﺛﺒﺎﺕ ﺩﻣﺎﯼ ﺁﺏ ﺧﺮﻭﺟﯽ ﮐﻤﮏ ﮐﻨﺪ.
○ ﺑﻠﯽ
ﺁﺏ ﺁﺷﭙﺰﺧﺎﻧﻪ /ﻇﺮﻑﺷﻮﯾﯽ
ﺁﯾﺎ ﻓﻀﺎﯾﯽ ﺑﺮﺍﯼ ﯾﮏ ﭼﯿﻠﺮ ﺑﯿﺮﻭﻧﯽ ﻭﺟﻮﺩ ﺩﺍﺭﺩ؟
ﺩﺭ ﺍﯾﻦ ﺣﺎﻟﺖ ،ﺁﺏ ﺷﯿﺮﯾﻦ ﺍﺳﺘﻔﺎﺩﻩ ﺷﺪﻩ ﻭ ﻧﯿﺎﺯﻣﻨﺪ ﺟﺪﺍﺳﺎﺯﯼ
○ ﺑﻠﯽ
○ ﺧﯿﺮ ○ ﺧﯿﺮ
ﺑﯿﻦ ﮐﻨﺪﺍﻧﺴﻮﺭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻭ ﻣﻨﺒﻊ ﺁﺏ ﺁﺷﺎﻣﯿﺪﻧﯽ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ
ﺍﮔﺮ ﭘﺎﺳــﺦ ﺗﻤﺎﻡ ﺳــﻮﺍﻝﻫﺎﯼ ﺑﺎﻻ ﻣﺜﺒﺖ ﺑــﻮﺩ ،ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ
ﺍﺯ ﻣﺒﺪﻝ ﺣﺮﺍﺭﺗﯽ ﻣﯿﺎﻧﯽ ﺍﺳــﺖ .ﻇﺮﻑﺷﻮﯾﯽ ﺗﺠﺎﺭﯼ ﺍﺯ ﺩﻣﺎﯼ ﺁﺏ
ﺣﺮﺍﺭﺗﯽ ﮐﺮﯾﺮ ،ﮔﺰﯾﻨﻪ ﻣﻨﺎﺳﺒﯽ ﺑﺮﺍﯼ ﮐﺎﺭﺑﺮﺩ ﻣﻮﺭﺩ ﻧﻈﺮ ﺷﻤﺎ ﺍﺳﺖ.
ﮔﺮﻣﯽ ﺑﯿــﺶ ﺍﺯ 150ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑــﺮﺍﯼ ﻣﻄﺎﺑﻘﺖ ﺑﺎ ﻗﻮﺍﻧﯿﻦ
ﺍﮔﺮ ﺑﺎﺭﻫﺎﯼ ﺳﺮﻣﺎﯾﺸــﯽ ﻭ ﮔﺮﻣﺎﯾﺸﯽ ﺑﯿﺶ ﺍﺯ ﻣﻘﺎﺩﯾﺮ ﺑﺎﻻ ﺑﻮﺩ ،ﺑﺎﯾﺪ
ﺑﻬﺪﺍﺷﺘﯽ ﻭ ﻟﻮﻟﻪﮐﺸﯽ ﻣﺤﻠﯽ ﺑﻬﺮﻩ ﻣﯽﺑﺮﺩ .ﺩﺭﻧﺘﯿﺠﻪ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ
ﺍﺯ ﭼﯿﻠﺮﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﭼﻨﺪﮔﺎﻧﻪ ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ.
ﺣﺮﺍﺭﺗﯽ ﺑﻬﺘﺮﯾﻦ ﮔﺰﯾﻨﻪ ﺑﺮﺍﯼ ﭘﯿﺶﮔﺮﻣﺎﯾﺶ ﺁﺏ ﺍﺳﺖ ﮐﻪ ﺩﺭ ﺗﺼﻮﯾﺮ ) (7ﻧﺸﺎﻥ ﺩﺍﺩﻩ ﺷﺪ.
ﺗﺤﻠﯿﻞ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﺍﻧﺮﮊﯼ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺯﯾــﺎﺩﯼ ﺑﺮﺍﯼ ﮔﺮﻣﺎﯼ ﺑﺎﺯﯾﺎﻓﺘﯽ ﻧﺎﺷــﯽ ﺍﺯ ﺍﺣﯿﺎﯼ
ﺍﺭﺯﯾﺎﺑﯽ ﮐﺎﺭﺑﺮﺩ ﺍﺣﺘﻤﺎﻟﯽ
ﮔﺮﻣﺎﯾﺸــﯽ ﺑﺎ ﭼﯿﻠﺮ 30RBﻭﺟﻮﺩ ﺩﺍﺭﺩ .ﺍﻟﺒﺘﻪ ﺑﺎﯾﺪ ﺍﻣﮑﺎﻥﭘﺬﯾﺮﯼ
ﺁﻥﭼﻪ ﺩﺭ ﺍﺩﺍﻣﻪ ﻣﯽﺁﯾﺪ ﺭﺍ ﻣﯽﺗﻮﺍﻥ ﺑﺮﺍﯼ ﺗﻌﯿﯿﻦ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﮐﺮﯾﺮ ﻣﻮﺭﺩ ﻧﻈﺮ ﺷــﻤﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﺍﺭﺯﯾﺎﺑــﯽ ﺍﻭﻟﯿﻪ ﻣﯽﺗﻮﺍﻧﺪ ﺑﻪ ﺑﺮﺭﺳــﯽ ﻣﻮﺍﺭﺩ ﻣﻬﻢ ﻣﻨﺎﺳﺐ ﭘﺮﻭﮊﻩ ﺷﻤﺎ ﺩﺭ ﺯﻣﯿﻨﻪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺗﻌﯿﯿﻦ ﺍﻣﮑﺎﻥﭘﺬﯾﺮﯼ ﺳﯿﺴــﺘﻢ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﻣﻘﺎﯾﺴــﻪ ﺍﻣﮑﺎﻥ ﺻﺮﻓﻪﺟﻮﯾــﯽ ﺩﺭ ﻫﺰﯾﻨﻪ ﺍﻧﺮﮊﯼ ﺑﯿﻦ ﺁﺏﮔﺮﻡﮐــﻦ ﻣﻌﻤﻮﻟﯽ ﻭ ﭼﯿﻠﺮ
ﮐﻤﮏ ﮐﻨﺪ.
ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﺳﺖ .ﺍﺳﺎﺱ ﺍﯾﻦ ﻣﻘﺎﯾﺴﻪ ﺑﺎﯾﺪ ﮔﺮﻣﺎﯼ ﭘﺪﯾﺪﺁﻣﺪﻩ،
ﺁﯾﺎ ﻧﯿﺎﺯ ﻣﺸﺎﺑﻬﯽ ﺑﻪ ﺁﺏ ﺳﺮﺩ ﻭ ﺁﺏ ﮔﺮﻡ ﻭﺟﻮﺩ ﺩﺍﺭﺩ؟ ○ ﺑﻠﯽ
ﻣﺎﻟﯽ ﺳﯿﺴــﺘﻢ ﺍﺯ ﻧﻈﺮ ﺍﻗﺘﺼﺎﺩﯼ ،ﺑﺮﺭﺳﯽ ﺷﻮﺩ .ﺭﺍﻫﯽ ﺳﺎﺩﻩ ﺑﺮﺍﯼ
ﻫﺰﯾﻨﻪ ﺳﻮﺧﺖ ﻭ ﮐﺎﺭﺍﯾﯽ ﻋﻤﻠﯿﺎﺗﯽ ﺁﻥﻫﺎ ﺑﺎﺷﺪ .ﺑﺮﺍﯼ ﺳﺎﺩﻩ ﮐﺮﺩﻥ
○ ﺧﯿﺮ
ﺁﯾﺎ ﺩﻣﺎﯼ ﺁﺏ ﮔﺮﻡ ﺳﯿﺴــﺘﻢ ﮔﺮﻣﺎﯾﺸﯽ ﺑﯿﻦ 59ﻭ 131ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺍﺳﺖ؟
ﺍﯾــﻦ ﺗﺤﻠﯿﻞ ،ﺻﺮﻓﻪﺟﻮﯾــﯽ ﺩﺭ ﻫﺰﯾﻨﻪ ﺍﻧــﺮﮊﯼ ﺗﻮﻟﯿﺪ ﯾﮏ ﻣﯿﻠﯿﻮﻥ Btuﮔﺮﻣﺎﯼ ﺧﺮﻭﺟﯽ ﺑﯿﻦ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻭ ﭼﻨﺪ ﺳﯿﺴــﺘﻢ
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 31ﺷﻤﺎﺭﻩ 30
ﺳﯿﺴﺘﻢ ﮔﺮﻣﺎﯾﺸﯽ ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ
ﺑﻮﯾﻠﺮ ﮔﺎﺯ ﻃﺒﯿﻌﯽ
ﺑﻮﯾﻠﺮﯼ ﺑﺎ ﺳﻮﺧﺖ ﻧﻔﺘﯽ
ﺑﻮﯾﻠﺮ ﺍﻟﮑﺘﺮﯾﮑﯽ ﮔﺮﻣﺎﯼ ﺧﺮﻭﺟﯽ ﻫﺰﯾﻨﻪ ﺳﻮﺧﺖ ﺍﻟﮑﺘﺮﯾﺴﯿﺘﻪ ﺳﻮﺧﺖ ﻧﻔﺘﯽ ﮔﺎﺯ ﻃﺒﯿﻌﯽ ﻋﺎﻣﻞ ﺗﺒﺪﯾﻞ ﺍﻧﺮﮊﯼ ﺍﻟﮑﺘﺮﯾﺴﯿﺘﻪ ﺳﻮﺧﺖ ﻧﻔﺘﯽ ﮔﺎﺯ ﻃﺒﯿﻌﯽ ﮐﺎﺭﺍﯾﯽ ﺿﺮﯾﺐ ﮐﺎﺭﺍﯾﯽ ﮔﺮﻣﺎﯾﺸﯽ ﮐﺎﺭﺍﯾﯽ ﻫﺰﯾﻨﻪ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺑﻪﺍﺯﺍﯼ MBH 1000
ﺻﺮﻓﻪﺟﻮﯾﯽ ﺑﻮﯾﻠﺮﻫﺎ
ﺗﺼﻮﯾﺮ ) (11ﺻﺮﻓﻪﺟﻮﯾﯽ ﺗﺤﻠﯿﻠﯽ ،ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺩﺭ ﺑﺮﺍﺑﺮ ﺑﻮﯾﻠﺮ ﺁﺏ ﮔﺮﻡ ﺁﺏ ﮔﺮﻡ ،ﻣﻘﺎﯾﺴــﻪ ﻣﯽﺷــﻮﻧﺪ .ﺗﺼﻮﯾﺮ ) (11ﻧﺸﺎﻥﺩﻫﻨﺪﻩ ﺗﺤﻠﯿﻞ
ﺳﻴﺴــﺘﻢﻫﺎﯼ ﭘﯿﻮﺳــﺘﻪ ﮔﺮﻣﺎﯾﺶ ﻭ ﺳــﺮﻣﺎﻳﺶ ﺑﻨﺎ ﺭﺍ ﻣﯽﺗﻮﺍﻥ
ﺩﺭ ﻫﺰﯾﻨﻪ ﺍﻧﺮﮊﯼ ﺭﺍ ﻧﺸــﺎﻥ ﻣﯽﺩﻫﺪ .ﻣﻼﺣﻈــﻪ ﺑﻬﺘﺮﯼ ﺩﺭ ﺯﻣﯿﻨﻪ
ﺍﺟﺰﺍﯼ ﺳﯿﺴﺘﻢ ،ﺍﺳﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺩﺭﯾﺎﻓﺖ ﮔﺮﻣﺎ ﺍﺯ ﺍﺣﯿﺎﯼ
ﺍﻣﮑﺎﻥ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﻫﺰﯾﻨﻪ ﺍﻧﺮﮊﯼ ،ﺷــﺎﻣﻞ ﻋﻤﻠﮑﺮﺩ ﺑﺨﺸــﯽ ﺍﺯ
ﮔﺮﻣﺎﯾﺶ ﺑﺎﯾﺪ ﻧﯿﺎﺯ ﻣﺸــﺎﺑﻬﯽ ﺑﻪ ﮔﺮﻣﺎﯾﺶ ﻭ ﺳﺮﻣﺎﯾﺶ ﻭﺟﻮﺩ ﺩﺍﺷﺘﻪ
ﺑﺎﺭ ﻣﺎﺷــﯿﻦ ﺣﺮﺍﺭﺗﯽ ﺍﺳــﺖ ،ﺩﺭﺣﺎﻟﯽ ﮐﻪ ﺗﺤﺖ ﺷﺮﺍﯾﻂ ﻣﻮﺭﺩ ﻧﻈﺮ
ﺑﺎﺷﺪ؛ ﺍﻟﺒﺘﻪ ﺳﯿﺴﺘﻢ ﻧﺸﺎﻥﺩﺍﺩﻩﺷﺪﻩ ﺩﺭ ﺗﺼﻮﯾﺮ ) (12ﻣﯽﺗﻮﺍﻧﺪ ﺗﻨﻬﺎ
ﺑﻮﺩﻩ ﻭ ﺁﺏ ﮔﺮﻡ ﻭ ﺳــﺮﺩ ﺗﻮﻟﯿﺪ ﻣﯽﮐﻨﺪ .ﺑﺮﻧﺎﻣﻪﻫﺎﯼ ﺗﺤﻠﯿﻞ ﺍﻧﺮﮊﯼ
ﺑﻪ ﺻﻮﺭﺕ ﺳﺮﻣﺎﯾﺸــﯽ ،ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾﺶ ﯾﺎ ﺣﺎﻻﺕ ﮔﺮﻣﺎﯾﺸﯽ ﺑﺮﺍﯼ
ﻣﺎﻧﻨﺪ ﺑﺮﻧﺎﻣﻪ ﺗﺤﻠﯿﻞ ﺳﺎﻋﺘﯽ ﮐﺮﯾﺮ ) HAP v 4.4ﯾﺎ ﭘﺲ ﺍﺯ ﺁﻥ( ﺑﻪ
ﺗﺎﻣﯿــﻦ ﺑﺎﺭ ﺗﻬﻮﯾﻪ ﻣﻄﺒــﻮﻉ ﺑﻨﺎ ،ﻋﻤﻞ ﮐﻨﺪ .ﺍﯾﻦ ﺳﯿﺴــﺘﻢ ﯾﮑﯽ ﺍﺯ
ﺑﺮﺭﺳﯽ ﻫﺰﯾﻨﻪ ﺳﺎﻟﯿﺎﻧﻪ ﺍﻧﺮﮊﯼ ﮐﻤﮏ ﮐﺮﺩﻩ ﻭ ﺍﻃﻼﻋﺎﺕ ﻣﻨﺎﺳﺒﯽ ﻧﯿﺰ
ﺍﻣﮑﺎﻧﺎﺕ ﺩﺭﯾﺎﻓﺖ ﮔﺮﻣﺎ ﺍﺯ ﭼﯿﻠﺮ ﺍﺣﯿــﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺮﺍﯼ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ
ﻣﻨﻄﺒﻖ ﺑﺮ ﺍﻧﺠﻤﻦ ﺧﺎﻧﻪ ﺳﺎﺯﯼ ﺳﺒﺰ ﺍﯾﺎﻻﺕ ﻣﺘﺤﺪﻩ ﺑﺮﺍﯼ ﻣﺪﯾﺮﯾﺖ
ﻣﻔﯿﺪ ﺍﺳــﺖ .ﺟﺮﯾﺎﻥ ﺍﺻﻠﯽ ﻣﺘﻐﯿﺮ ﺳﯿﺴﺘﻢ ﺁﺏ ﺳﺮﺩ ﺩﺭ ﺯﯾﺮ ﺗﻌﺮﯾﻒ
ﻃﺮﺍﺣﯽ ﻣﺤﯿﻄﯽ ﻭ ﺍﻧﺮﮊﯼ ) (LEEDﻓﺮﺍﻫﻢ ﻣﯽﺁﻭﺭﺩ .ﻧﺮﻡﺍﻓﺰﺍﺭ ﮐﺮﯾﺮ
ﺷﺪﻩ ﺍﺳﺖ؛ ﺍﻟﺒﺘﻪ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺟﺎﯾﮕﺰﯾﻨﯽ ﻣﺎﻧﻨﺪ ﺳﯿﺴﺘﻢ ﺁﺏ ﺳﺮﺩ
) HAP v 4.4ﯾــﺎ ﭘــﺲ ﺍﺯ ﺁﻥ( ،ﻗﺎﺑﻠﯿــﺖ ﺗﻮﻟﯿﺪ ﺗﻤــﺎﻡ ﺍﻋﺘﺒﺎﺭ 1
ﺍﻭﻟﯿﻪ -ﺛﺎﻧﻮﯾﻪ ﻧﯿﺰ ﺍﻣﮑﺎﻥﭘﺬﯾﺮ ﺍﺳــﺖ .ﺩﺭ ﻫﺮ ﺳﯿﺴــﺘﻢ ،ﭘﻤﭗﻫﺎﯼ
ﺑﻪ ﺷــﮑﻞ ﺍﻟﮕﻮﯼ ﺍﻋﺘﺒﺎﺭﯼ ﺁﻧﻼﯾﻦ USGBCﺩﺍﺭﺩ .ﺍﯾﻦ ﺍﻣﺮ ﺑﺎﻋﺚ ﺻﺮﻓﻪﺟﻮﯾــﯽ ﺩﺭ ﺯﻣــﺎﻥ ﺟﺎﯾﮕﺰﯾﻨﯽ ﺑﺎ ﺗﻮﺳــﻌﻪ ﺍﺷــﮑﺎﻝ ﺍﻋﺘﺒﺎﺭﯼ LEED (v3.0) EAc1ﻣﯽﺷﻮﺩ.
ﻫﻤﭽﻨﯿﻦ ﺩﻣﺎﯼ ﺁﺏ ﮔﺮﻡ ﺑﺮﮔﺸﺘﯽ ﺍﺯ ﺳﯿﺴﺘﻢ ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ ،ﮐﻤﺘﺮ ﺍﺯ ﺣــﺪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﺳــﺖ ﺗﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﮐﺎﺭﺍ ﺷــﻮﺩ .ﺍﮔﺮ ﺩﻣﺎﯼ ﺁﺏ ﻣﺨﻠﻮﻁﺷــﺪﻩ ﺑﺎ ﻣﺨﺰﻥ ﺫﺧﯿــﺮﻩ ﺑﯿﻦ 59ﻭ 104ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺎﺷــﺪ ،ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﭼﯿﻠﺮ ،ﺿﺮﻭﺭﯼ ﺧﻮﺍﻫﺪ ﺑﻮﺩ.
ﺭﺍﻫﻨﻤﺎﯼ ﺍﻧﺘﺨﺎﺏ ﺗﺠﻬﯿﺰﺍﺕ
ﺷــﯿﺮ ﮐﻨﺘﺮﻟﯽ ﺑﺎ ﺩﻭ ﻣﺴﯿﺮ ،ﭘﺎﯾﯿﻦ ﻫﺮ ﭼﯿﻠﺮ ﻗﺮﺍﺭ ﮔﺮﻓﺘﻪ ﻭ ﺑﻪ ﻭﺳﯿﻠﻪ
ﻭﻗﺘــﯽ ﭼﯿﻠــﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﻧﺘﺨﺎﺏ ﺷــﺪ ،ﻫﻤــﻮﺍﺭﻩ ﺭﻭﻧﺪ
ﺳﯿﮕﻨﺎﻝ ﮐﻨﺘﺮﻝ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﭼﯿﻠﺮ ،ﮐﻨﺘﺮﻝ ﻣﯽﺷﻮﺩ .ﭘﻤﭗ ﺍﺣﯿﺎﯼ
ﺳــﺎﺯﻧﺪﻩ ﺭﺍ ﺩﺭ ﺍﻧﺘﺨﺎﺏ ﺍﺑﺰﺍﺭ ﺩﺭﻧﻈﺮ ﺑﮕﯿﺮﯾﺪ .ﺑﺮﻧﺎﻣﻪ ﺳﺎﺯﻧﺪﻩ ﭼﯿﻠﺮ
ﺣﺮﺍﺭﺗﯽ ﺑﺎ ﻣﺤﺮﮐﻪ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ ﺑﻪ ﻭﺳﯿﻠﻪ ﺍﺧﺘﻼﻑ ﻓﺸﺎﺭ ﺳﯿﺴﺘﻢ
ﺑﺴــﺘﻪ ﮐﺮﯾﺮ ) v3.29hﯾﺎ ﭘﺲ ﺍﺯ ﺁﻥ( ﺑﻪ ﺍﻧﺘﺨﺎﺏ ﺁﺳــﺎﻥﺗﺮ ﺍﺣﯿﺎﯼ
ﮐﻨﺘﺮﻝ ﻣﯽﺷــﻮﺩ .ﺷﯿﺮﯼ ﺑﺎ ﺩﻭ ﻣﺴــﯿﺮ ﻭ ﺳﯿﺴﺘﻢ ﭘﻤﭗ ﺑﺎ ﻣﺤﺮﮐﻪ
ﺣﺮﺍﺭﺗﯽ ﻭ ﭼﯿﻠﺮ ﮐﻤﮏ ﻣﯽﮐﻨﺪ.
ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ ،ﺑﻬﺘﺮﯾﻦ ﺭﺍﻩ ﮐﻨﺘﺮﻝ ﺿﺮﻭﺭﯼ ﻓﺸــﺎﺭ ﺍﺻﻠﯽ ﺑﻮﺩﻩ ﻭ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﻠﻔﻦ55401278 :
ﺍﺗﻤﺴﻔﺮ ﻭ ﺍﻧﺮﮊﯼ (LEED) EAc1ﺭﺍ ﺑﻪ ﺻﻮﺭﺕ ﺍﻟﮕﻮﯼ ﺍﻃﻼﻋﺎﺗﯽ
ﺍﺣﯿــﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺎﯾﺪ ﻗﺎﺩﺭ ﺑﻪ ﮐﺎﺭ ﺑﺎ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺎﺷــﻨﺪ.
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻣﺜﺎﻝ ﺗﺼﻮﯾــﺮ ) ،(11ﺗﺨﻤﯿﻨﯽ ﺳــﺎﺩﻩ ﺍﺯ ﺍﻣﮑﺎﻥ ﺻﺮﻓﻪﺟﻮﯾﯽ
ﺑــﺎ ﺗﻮﺟﻪ ﺩﻗﻴﻖ ﺑــﻪ ﻣﺤﺪﻭﺩﯾﺖﻫﺎﯼ ﮐﺎﺭﺑــﺮﺩﯼ ﻭ ﺍﻟﺰﺍﻣﺎﺕ ﮐﻨﺘﺮﻝ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﻣﻘﺎﯾﺴﻪ ﺍﯾﻦ ﺳﯿﺴﺘﻢﻫﺎ ﺍﺳﺖ.
ﺳﯿﺴﺘﻤﯽ ﺑﺎ ﭼﻨﺪ ﭼﯿﻠﺮ ﻭ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺳــﺎﺩﻩﺍﯼ ﺑﺮﺍﯼ ﺗﻌﯿﯿﻦ ﺍﻣــﮑﺎﻥ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﻫﺰﯾﻨــﻪ ﺍﻧﺮﮊﯼ ﺑﺎ
ﻣﻼﺣﻈﺎﺕ ﻃﺮﺍﺣﯽ ﺳﯿﺴﺘﻢ
ﺻﻔﺤﻪ / 32ﺷﻤﺎﺭﻩ 30
ﭼﺮﺧﻪ ﺁﺏ ﺳﺮﺩ ﺍﻭﻟﯿﻪ
ﭼﺮﺧﻪ ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ
ﭼﺮﺧﻪ ﺍﺣﯿﺎﯼ ﺑﻨﺎ ﭼﯿﻠﺮ ﺑﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﺍﺯ ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ
ﺑﻪ ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ
ﭘﻤﭗﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺎ ﻣﺤﺮﮐﻪ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ
ﻣﺨﺰﻥ ﺫﺧﯿﺮﻩ
ﭘﻤﭗﻫﺎﯼ ﺁﺏ ﮔﺮﻡ
ﭘﻤﭗﻫﺎﯼ ﺁﺏ ﺳﺮﺩ ﺑﺎ ﻣﺤﺮﮐﻪ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ ﻫﯿﺘﺮ ﮐﻤﮑﯽ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺗﺼﻮﯾﺮ ) (12ﺳﯿﺴﺘﻢ ﭼﯿﻠﺮ ﭼﻨﺪﮔﺎﻧﻪ ﺑﺎ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺮﺍﯼ ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ
ﺑﺎﻋﺚ ﮐﺎﻫﺶ ﺍﻧﺮﮊﯼ ﺩﺭ ﭘﻤﭗ ﻧﯿﺰ ﻣﯽﺷــﻮﻧﺪ .ﻣﯽﺗﻮﺍﻥ ﺍﺯ ﺷﯿﺮﻫﺎﯼ
ﺛﺎﻧﻮﯾﻪ ،ﻣﻨﺒﻊ ﺁﺏ ﺳــﺮﺩ ﺭﺍ ﮐﻨﺘﺮﻝ ﺧﻮﺍﻫﺪ ﮐﺮﺩ .ﺳــﭙﺲ ﺳﻮﻣﯿﻦ
ﺳﻪﻣﺴﯿﺮﻩ ﺑﺮﺍﯼ ﻫﺮ ﭼﯿﻠﺮ ﺍﺳﺖ؛ ﻭﻟﯽ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﭘﻤﭗ ﺍﻓﺰﺍﯾﺶ
ﺷﯿﺮ ﺩﻭﻣﺴﯿﺮﻩ ﺑﺎﺯ ﺷــﺪﻩ ﻭ ﭼﯿﻠﺮ ﺁﻥ ﺩﺭﺻﻮﺭﺗﯽ ﮐﻪ ﻧﯿﺎﺯ ﺑﻪ ﺗﺎﻣﯿﻦ
ﺧﻮﺍﻫﺪ ﯾﺎﻓﺖ.
ﺩﻣﺎﯼ ﺁﺏ ﺳﺮﺩ ﺍﻭﻟﯿﻪ ﺑﺎﺷﺪ ،ﺁﺏ ﺳﺮﺩ ﺭﺍ ﺗﺎﻣﯿﻦ ﺧﻮﺍﻫﺪ ﮐﺮﺩ.
ﺁﻧﭽــﻪ ﺩﺭ ﺍﺩﺍﻣﻪ ﻣﯽﺁﯾﺪ ،ﮐﺎﺭﺑﺮﺩ ﺍﺟﺰﺍﯼ ﻣﺨﺘﻠﻒ ﺳﯿﺴــﺘﻢ ﺩﺭ ﺣــﺎﻻﺕ ﻋﻤﻠﯿﺎﺗﯽ ﮔﻮﻧﺎﮔﻮﻥ ﺍﺳــﺖ .ﺍﯾﻦ ﺳﯿﺴــﺘﻢ ،ﺁﺏ ﺳــﺮﺩ ﺭﺍ ﺑﻪﻣﻨﻈﻮﺭ ﺳــﺮﻣﺎﯾﺶ ﺑﻨﺎ ﺗﻮﻟﯿﺪ ﮐﺮﺩﻩ ،ﮔﺮﻣﺎﯾﺶ ﺍﺣﯿﺎﺷﺪﻩ ﺭﺍ ﺑﺎ ﺁﺏ ﻣﺨــﺰﻥ ﺫﺧﯿﺮﻩ ﺁﻣﯿﺨﺘﻪ ﻭ ﺁﺏ ﮔﺮﻡ ﺭﺍ ﺑﺮﺍﯼ ﺍﻫﺪﺍﻑ ﮔﺮﻣﺎﯾﺸــﯽ ﺑﻨﺎ ﺑﻪ ﻣﺼﺮﻑ ﻣﯽﺭﺳﺎﻧﺪ.
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺑﻪﻣﻨﻈﻮﺭ ﺳــﺮﻣﺎﯾﺶ ،ﺷﯿﺮ ﮐﻨﺘﺮﻝ ﺁﺏ ﺳﺮﺩ ،ﮐﻨﺘﺮﻝ ﻣﺤﺮﮐﻪ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ ﭘﻤﭗ ﺁﺏ ﺳــﺮﺩ ﻭ ﮐﻨﺘﺮﻝ ﺩﻣﺎﯼ ﺁﺏ ﺳــﺮﺩ ﻣﺎﻧﻨﺪ ﺣﺎﻟﺖ ﺳــﺮﻣﺎﯾﺶ ﺗﮏ ﺑﺎﻻ ،ﻋﻤــﻞ ﺧﻮﺍﻫﻨﺪ ﮐﺮﺩ .ﻫﻢﺯﻣﺎﻥ ،ﭼﯿﻠﺮ ﻫﺎﺩﯼ ﺷــﯿﺮ ﺩﻭﻣﺴــﯿﺮﻩ ،ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾﺸــﯽ ﺧــﻮﺩ ﺭﺍ ﺗﺎ ﺣﺪﺍﻗﻞ
ﺣﺎﻟﺖ ﺳﺮﻣﺎﯾﺶ ﺗﮏ ﺗﻠﻔﻦ88739880-2:
ﺣﺎﻟﺖ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ
ﻣﻮﻗﻌﯿﺖ ﺧﻮﺩ ﺑﺎﺯ ﮐﺮﺩﻩ ﻭ ﺑﻪ ﭘﻤﭗ ﺍﺣﯿﺎ ،ﺍﻣﮑﺎﻥ ﻣﯽﺩﻫﺪ ﺗﺎ ﺩﻣﺎﯼ
ﺑﻪﻣﻨﻈﻮﺭ ﺳﺮﻣﺎﯾﺶ ،ﺷﯿﺮ ﺁﺏ ﺳﺮﺩ ﺩﻭﻣﺴﯿﺮﻩ ﮐﻪ ﭼﯿﻠﺮ ﺭﺍ ﺗﻐﺬﯾﻪ
ﺁﺏ ﻭﺭﻭﺩﯼ ﺭﺍ ﺑﺮﺭﺳــﯽ ﮐﻨﺪ ﺩﺭ ﺍﯾﻦ ﺻﻮﺭﺕ ﻣﻌﻠﻮﻡ ﺷﻮﺩ ﮐﻪ ﻧﯿﺎﺯﯼ
ﻣﯽﮐﻨﺪ ،ﺑﺎﺯ ﺑﻮﺩﻩ ﻭ ﭘﻤﭗ ﺁﺏ ﺳﺮﺩ ،ﺟﺮﯾﺎﻥ ﺭﺍ ﺗﺎﻣﯿﻦ ﺧﻮﺍﻫﺪ ﮐﺮﺩ.
ﺑﻪ ﺍﻓــﺰﻭﺩﻥ ﮔﺮﻣﺎ ﺑﻪ ﭼﺮﺧﻪ ﺍﺣﯿﺎﯼ ﮔﺮﻣﺎﯾــﯽ ﻭﺟﻮﺩ ﺩﺍﺭﺩ ﯾﺎ ﺧﯿﺮ.
ﺟﺮﯾﺎﻥ ﺁﺏ ﺳــﺮﺩ ﺍﻭﻟﯿﻪ ﻣﺘﻐﯿﺮ ﺑﻪ ﻭﺳــﯿﻠﻪ ﻣﺤﺮﮐﻪ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ
ﺟﺮﯾﺎﻥ ﺁﺏ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﻪ ﻭﺳــﯿﻠﻪ ﭘﻤــﭗ ﻣﺤﺮﮐﻪ ﺑﺎ ﻓﺮﮐﺎﻧﺲ
ﭘﻤﭗ ﺁﺏ ﺳﺮﺩ ﺑﺮ ﻣﺒﻨﺎﯼ ﺳﯿﮕﻨﺎﻝ ﺍﺧﺘﻼﻑ ﻓﺸﺎﺭ ﭼﺮﺧﻪ ﻟﻮﻟﻪﮐﺸﯽ
ﻣﺘﻐﯿﺮ ﻓﺮﺍﻫﻢﺷﺪﻩ ﻭ ﺑﻪ ﻭﺳﯿﻠﻪ ﺳﯿﮕﻨﺎﻝ ﺍﺧﺘﻼﻑ ﻓﺸﺎﺭ ﻟﻮﻟﻪﮐﺸﯽ
ﺁﺏ ﺳــﺮﺩ ﮐﻨﺘﺮﻝ ﻣﯽﺷــﻮﺩ .ﭼﯿﻠﺮ ،ﺩﻣﺎﯼ ﺁﺏ ﺳــﺮﺩ ﺧﺮﻭﺟﯽ ﺭﺍ
ﭼﺮﺧﻪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﮐﻨﺘﺮﻝ ﻣﯽﺷــﻮﺩ .ﭼﯿﻠــﺮ ،ﻣﻘﺪﺍﺭ ﺣﺮﺍﺭﺗﯽ
ﺩﺭ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ ﺧﻮﺩ ،ﮐﻨﺘﺮﻝ ﻣﯽﮐﻨﺪ .ﮐﻨﺪﺍﻧﺴــﻮﺭﻫﺎﯼ ﻫﻮﺍﯾﯽ
ﺭﺍ ﺗﻌﯿﯿــﻦ ﻣﯽﮐﻨــﺪ ﮐﻪ ﺑﺎﯾﺪ ﺑﻪ ﭼﺮﺧــﻪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗــﯽ ﺑﺮ ﭘﺎﯾﻪ
ﭼﯿﻠﺮ ،ﮔﺎﺯ ﺳﺮﻣﺎﯾﺸﯽ ﺭﺍ ﻣﺘﺮﺍﮐﻢ ﻭ ﮐﻨﺪﺍﻧﺴﻮﺭﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ،
ﺍﺧﺘﻼﻑ ﺁﻥ ﺑﺎ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ ﺍﻓﺰﻭﺩﻩ ﺷــﻮﺩ .ﭼﯿﻠﺮ ﻣﻘﺪﺍﺭ ﺣﺮﺍﺭﺕ
ﺧﺎﻣﻮﺵ ﺑﺎﻗــﯽ ﻣﯽﻣﺎﻧﻨــﺪ .ﺩﺭﻧﺘﯿﺠﻪ ،ﻫﯿﭻ ﮔﺮﻣﺎﯾــﯽ ﺑﻪ ﭼﺮﺧﻪ
ﺍﻓﺰﻭﺩﻩﺷﺪﻩ ﺭﺍ ﺑﺎ ﺭﺳــﯿﺪﻥ ﺩﻣﺎﯼ ﺁﺏ ﻭﺭﻭﺩﯼ ﺑﻪ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ،
ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﻓﺰﻭﺩﻩ ﻧﻤﯽﺷــﻮﺩ .ﺩﺭ ﺍﯾــﻦ ﺣﺎﻟﺖ ،ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ
ﮐﺎﻫﺶ ﻣﯽﺩﻫﺪ .ﻭﻗﺘﯽ ﺩﯾﮕﺮ ﭼﯿﻠﺮﻫﺎ ﺁﻣﺎﺩﻩ ﺍﻓﺰﺍﯾﺶ ﺑﺎﺭ ﺳﺮﻣﺎﯾﺸﯽ
ﺗﺎﻣﯿﻦ ﻧﺨﻮﺍﻫﺪ ﺷــﺪ .ﺍﮔﺮ ﻧﺘﻮﺍﻥ ﺩﻣﺎﯼ ﺁﺏ ﺳــﺮﺩ ﺍﻭﻟﯿﻪ ﺭﺍ ﺑﺎ ﯾﮏ
ﺷﺪﻧﺪ ،ﺷﯿﺮﻫﺎﯼ ﺩﻭﻣﺴﯿﺮﻩ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﺎﺯ ﻣﯽﺷﻮﻧﺪ ﺗﺎ ﺍﻣﮑﺎﻥ
ﭼﯿﻠﺮ ﺗﺎﻣﯿﻦ ﮐﺮﺩ ،ﺷﯿﺮ ﺁﺏ ﺳﺮﺩ ﺩﻭﻣﺴﯿﺮﻩ ﺑﺮ ﭼﯿﻠﺮ ﺛﺎﻧﻮﯾﻪ ﺑﺎﺯ ﺷﺪﻩ
ﺍﻓﺰﻭﺩﻥ ﮔﺮﻣﺎ ﺑﻪ ﭼﺮﺧﻪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻓﺮﺍﻫﻢ ﺁﯾﺪ .ﺍﮔﺮ ﺩﻣﺎﯼ ﺁﺏ
ﻭ ﺑﺎﻋﺚ ﺟﺎﺭﯼ ﺷــﺪﻥ ﺁﺏ ﺳﺮﺩ ﺑﻪ ﭼﯿﻠﺮ ﺛﺎﻧﻮﯾﻪ ﺧﻮﺍﻫﺪ ﺷﺪ .ﭼﯿﻠﺮ
ﻭﺭﻭﺩﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺑﯿﻦ 59ﻭ 104ﺩﺭﺟﻪ ﻓﺎﺭﻧﻬﺎﯾﺖ ﺑﺎﺷــﺪ،
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 33ﺷﻤﺎﺭﻩ 30
ﺷﯿﺮ ﺩﻭﻣﺴــﯿﺮﻩ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ،ﯾﮏ ﺳــﯿﮕﻨﺎﻝ ﺁﻧﺎﻟﻮﮒ ﺍﺯ ﭼﯿﻠﺮ
ﻫﺰﯾﻨﻪ ﻋﻤﻠﯿﺎﺗﯽ ،ﭘﺎﯾﯿﻦ ﺁﻣﺪﻥ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﻭ ﺣﺮﮐﺖ ﺑﻪ ﺳــﻤﺖ
ﺩﺭﯾﺎﻓﺖ ﻭ ﺷــﯿﺮ ﺑﺮﺍﯼ ﺗﺎﻣﯿﻦ ﮐﻨﺘﺮﻝ ﻣﻨﺎﺳﺐ ﻓﺸﺎﺭ ﺍﺻﻠﯽ ﺗﻨﻈﯿﻢ
ﺗﺠﺪﯾﺪﭘﺬﯾﺮﯼ ﺩﺭ ﺍﻧﺮﮊﯼ ﺧﻮﺍﻫﺪ ﺷــﺪ .ﻃﺮﺍﺣﯽ ﺗﺨﺼﺼﯽ ﺑﺎ ﺗﻮﺟﻪ
ﻣﯽﺷــﻮﺩ .ﻫﻢﺯﻣﺎﻥ ﭘﻤﭗﻫﺎﯼ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻣﺤﺮﮐﻪ ﺳــﯿﮕﻨﺎﻝ
ﺑﻪ ﻧﯿﺎﺯﻫﺎﯼ ﮐﺎﺭﺑﺮﺩﯼ ،ﺍﻟﺰﺍﻣﺎﺕ ﺳﯿﺴﺘﻢ ﻭ ﻗﺎﺑﻠﯿﺖﻫﺎﯼ ﺍﺟﺰﺍ ﺑﺮﺍﯼ
ﻣﺘﻐﯿﺮ ،ﺟﺮﯾﺎﻥ ﺁﺏ ﺭﺍ ﺑﺮﺍﯼ ﺗﺎﻣﯿﻦ ﺍﺧﺘﻼﻑ ﻓﺸﺎﺭ ﺳﯿﺴﺘﻢ ،ﺗﻨﻈﯿﻢ
ﺗﻮﺳﻌﻪ ﺳﯿﺴــﺘﻢ ﺩﺭ ﺭﺳﯿﺪﻥ ﺑﻪ ﺍﻫﺪﺍﻑ ﺁﻥ ﮐﺎﻣﻼ ﺩﺭﮎ ﻣﯽﺷﻮﺩ.
ﺧﻮﺍﻫﻨﺪ ﮐﺮﺩ .ﺳﯿﺴــﺘﻢ ﮐﻨﺘﺮﻝ ﮔﺮﻣﺎﯾﺸﯽ ﺑﻨﺎ ،ﭘﻤﭗﻫﺎﯼ ﺁﺏ ﮔﺮﻡ
ﺑــﺎ ﻓﻬﻢ ﮐﺎﻣﻞ ﺍﯾــﻦ ﻧﯿﺎﺯﻫﺎ ﻭ ﻋﻤﻞ ﺩﻗﯿﻖ ﺑﺮﻃﺒــﻖ ﺁﻥﻫﺎ ،ﮐﺎﺭﺍﯾﯽ
ﺭﺍ ﺗﻐﺬﯾــﻪ ﮐﺮﺩﻩ ﻭ ﺩﺭﺻﻮﺭﺕ ﻟــﺰﻭﻡ ،ﻫﯿﺘﺮ ﮐﻤﮑﯽ ﺑﻪ ﺗﺎﻣﯿﻦ ﺩﻣﺎﯼ
ﺩﺭ ﺍﻧــﺮﮊﯼ ﻭ ﻣﺰﺍﯾﺎﯼ ﻋﻤﻠﯿﺎﺗﯽ ﺗﺤﻘﻖ ﻣﯽﯾﺎﺑﻨــﺪ .ﺑﺎﺯﯾﺎﺑﯽ ﮔﺮﻣﺎﯾﯽ
ﭼﺮﺧﻪ ﮔﺮﻣﺎﯾﺸﯽ ﺑﻨﺎ ﺧﻮﺍﻫﺪ ﭘﺮﺩﺍﺧﺖ.
ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﮐﺮﯾﺮ ،ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﺴﻮﻭﻟﯿﺖ ﺯﯾﺴــﺖﻣﺤﯿﻄﯽ ﺩﺭ ﻗﺒﺎﻝ ﺻﺮﻓﻪﺟﻮﯾﯽ ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺍﻧﺘﺨﺎﺑﯽ
ﺣﺎﻟﺖ ﮔﺮﻣﺎﯾﺸﯽ ﺳﯿﺴﺘﻢ ﮐﻨﺘﺮﻝ ﮔﺮﻣﺎﯾﺸﯽ ﺑﻨﺎ ﻭ ﻫﯿﺘﺮ ﮐﻤﮑﯽ ﮐﻪ ﻣﻌﻤﻮﻻ ﯾﮏ ﺑﻮﯾﻠﺮ ﺍﺳــﺖ ،ﺗﻤﺎﻡ ﻧﯿﺎﺯﻫﺎﯼ ﮔﺮﻣﺎﯾﺸﯽ ﺑﻨﺎ ﺭﺍ ﺗﺎﻣﯿﻦ ﺧﻮﺍﻫﻨﺪ ﮐﺮﺩ. ﺑــﻪ ﺩﻟﯿﻞ ﺁﻥﮐﻪ ﻧﯿﺎﺯﯼ ﺑﻪ ﺁﺏ ﺳــﺮﺩ ﻭﺟﻮﺩ ﻧــﺪﺍﺭﺩ ،ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺩﺭ ﺍﯾﻦ ﺣﺎﻟــﺖ ﺧﺎﻣﻮﺵ ﻣﺎﻧﺪﻩ ﻭ ﻫﯿﭻ ﮔﺮﻣﺎﯾﯽ ﺑﻪ ﭼﺮﺧﻪ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﺍﻓﺰﻭﺩﻩ ﻧﻤﯽﺷﻮﺩ.
ﻣﻨﺎﺳﺐ ﺍﺳﺖ. ﺩﺭ ﮐﺎﺭﺑﺮﺩﻫﺎ ،ﺍﺯ ﻫﺘﻞﻫﺎ ﮔﺮﻓﺘﻪ ﺗﺎ ﺑﯿﻤﺎﺭﺳﺘﺎﻥﻫﺎ ﻭ ﺩﺍﻧﺸﮕﺎﻩﻫﺎ، ﺗﺎﻣﯿﻦ ﺁﺏ ﮔﺮﻡ ﺑﺮﺍﯼ ﮔﺮﻣﺎﯾﺶ ﺑﻨﺎ ،ﮔﺮﻣﺎﯾﺶ ﺍﺳﺘﺨﺮ ﯾﺎ ﭘﯿﺶﮔﺮﻣﺎﯾﺶ ﻣﻨﺎﺑﻊ ﺁﺏ ﺧﺎﻧﮕﯽ ،ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻧﻪﺗﻨﻬﺎ ﻣﻤﮑﻦ ،ﺭﻭﺵ ﺑﺴــﯿﺎﺭ ﻣﻮﺛــﺮﯼ ﺑﺮﺍﯼ ﮐﺎﻫــﺶ ﻣﺼﺮﻑ ﻭ ﻫﺰﯾﻨﻪﻫﺎﯼ ﺍﻧﺮﮊﯼ ﺍﺳــﺖ .ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗﯽ ﻣﮑﻤﻞ ﻓﻮﻕﺍﻟﻌﺎﺩﻩﺍﯼ ﺑﺮﺍﯼ ﺳﯿﺴﺘﻢﻫﺎﯼ ﮔﺮﻣﺎﯾﺸﯽ
ﻧﺘﻴﺠﻪﮔﯿﺮﯼ
ﺑﺎ ﺳــﻮﺧﺖ ﻓﺴﯿﻠﯽ ﺍﺳﺖ ﺗﺎ ﺑﻪ ﺣﺪﺍﮐﺜﺮ ﻣﻮﺍﺭﺩ ﺍﻋﺘﺒﺎﺭ 1ﺍﺗﻤﺴﻔﺮ ﻭ
ﺣــﺎﻝ ﺗﻠﻒ ﻣﯽﺷــﺪ ﻭ ﺗﺒﺪﯾﻞ ﺁﻥ ﺑﻪ ﺍﻧﺮﮊﯼ ﻣﻔﯿــﺪ ،ﺑﺎﻋﺚ ﮐﺎﻫﺶ
ﻋﻤﻠﯽ ﺍﺳﺖ.
ﺳﺎﺯﻧﺪﻩ ﻣﺮﻏﻮﺏﺗﺮﯾﻦ ﻓﻦﮐﻮﯾﻞ ﺳﺎﺧﺖ ﺍﯾﺮﺍﻥ ﻓﻦﮐﻮﯾﻞﻫـﺎﯼ ﻃﺮﺡ ﺻﺒﺎ ﺳﺎﺧﺘﻪﺷـﺪﻩ ﺍﺯ ﻣﺮﻏﻮﺏﺗﺮﯾﻦ ﻣـﻮﺍﺩ ﺍﻭﻟﯿﻪ ﻭ ﭘﯿﺸﺮﻓﺘﻪﺗﺮﯾﻦ ﻣﺘﺪﻫﺎﯼ ﺳﺎﺧﺖ ﻭ ﺗﺠﻬﯿﺰﺍﺕ ﺑﺴﯿﺎﺭ ﭘﯿﺸﺮﻓﺘﻪ ،ﺩﺭ ﺍﻏﻠﺐ ﮐﺎﺭﺑﺮﯼﻫﺎﯼ ﻣﺴﮑﻮﻧﯽ ،ﺗﺠﺎﺭﯼ ﻭ ﺍﺩﺍﺭﯼ ،ﻧﯿﺎﺯ ﺑﻬﺮﻩﺑﺮﺩﺍﺭﺍﻥ ﺍﯾﻦ ﺗﺠﻬﯿﺰﺍﺕ ﺭﺍ ﺑﺮﻃﺮﻑ ﻣﯽﻧﻤﺎﯾﺪ. ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺑﻪ ﺗﻤﺎﻡ ﺍﯾﻦ ﻣﺴــﺎﯾﻞ ﺍﺳﺖ .ﺑﻪ ﺩﺳــﺖ ﺁﻭﺭﺩﻥ ﺣﺮﺍﺭﺗﯽ ﮐﻪ ﺩﺭ ﻫﺮ
ﺁﺏ ﮔــﺮﻡ ،ﮐﺎﻣﻼ ﺑــﺎ ﭼﯿﻠﺮ ﺍﺣﯿﺎﯼ ﺣﺮﺍﺭﺗــﯽ 30RBﺍﻣﮑﺎﻥﭘﺬﯾﺮ ﻭ
ﺗﻠﻔﻦ55401278 :
ﺍﺯ ﺳﯿﺴــﺘﻢ ﺁﺏ ﺳــﺮﺩ ﺍﻫﻤﯿﺖ ﺯﯾﺎﺩﯼ ﯾﺎﻓﺘﻪ ﻭ ﭘﺎﺳــﺨﯽ ﻣﻨﺎﺳﺐ
ﻋﻤﻠﯿﺎﺗﯽ ﯾﺎ ﮐﺎﻫﺶ ﺍﺛﺮ ﮐﺮﺑﻦ ﺩﺭ ﺑﻨﺎ ،ﺑﺎﺯﯾﺎﺑﯽ ﮔﺮﻣﺎﯾﯽ ﺍﺯ ﺳﯿﺴــﺘﻢ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺍﻧﺮﮊﯼ ﻭ ﺗﺎﺛﯿﺮﺍﺕ ﺁﻥﻫﺎ ﺑﺮ ﺍﻗﺘﺼﺎﺩ ﻭ ﻣﺤﯿﻂ ﺯﯾﺴﺖ ،ﺑﺎﺯﯾﺎﺑﯽ ﺣﺮﺍﺭﺗﯽ
90.1 - 2007ﯾــﺎ ﻭﺭﺍﯼ ﺁﻥ ﺑﺎﺷــﻨﺪ .ﺑﺮﺍﯼ ﮐﺎﻫــﺶ ﻫﺰﯾﻨﻪﻫﺎﯼ
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﺑــﺎ ﺍﻓﺰﺍﯾﺶ ﺭﻭﺯﺍﻓــﺰﻭﻥ ﻫﺰﯾﻨﻪﻫﺎﯼ ﺍﻧــﺮﮊﯼ ،ﺑﺎﻻﺭﻓﺘﻦ ﻣﺼﺮﻑ
ﺍﻧﺮﮊﯼ LEED - NCﺭﺳــﯿﺪﻩ ﻭ ﻣﻨﻄﺒﻖ ﺑﺎ ﺍﻟﺰﺍﻣﺎﺕ ASHRAE
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﺻﻔﺤﻪ / 34ﺷﻤﺎﺭﻩ 30
ﻛﺎﺭﺑﺮﺩﻯ
ﺗﺠﻬﯿﺰﺍﺕ ﺟﺎﻧﺒﯽ ،ﻗﺴﻤﺖﻫﺎﯾﯽ ﻫﺴﺘﻨﺪ
ﺍﯾﻦ ﻟﺮﺯﻩﮔﯿﺮ ﺑﯿﻦ ﭘﯿﭻ ﺗﻨﻈﯿﻢ ﻭ ﻣﺤﻔﻈﻪ ﻓﻦ
ﻋﻼﻭﻩ ﺑﺮ ﺷﺎﺳــﯽ ﺑﻪ ﻣﺎﺩﻩ ﺿﺪﺍﺭﺗﻌﺎﺵ ﻧﯿﺎﺯ
ﮐﻪ ﺑﺮﺍﯼ ﻧﺼﺐ ﻧﻬﺎﯾﯽ ﺑﻪ ﻓﻦ ﺍﺿﺎﻓﻪ ﻣﯽﺷﻮﻧﺪ.
ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ )ﺗﺼﻮﯾﺮ .(1ﻫﻤﭽﻨﯿﻦ ﻓﻦ ﺭﻭﯼ
ﺩﺍﺭﻧﺪ .ﺍﯾﻦ ﻭﺳﯿﻠﻪ ﻣﺎﻧﻊ ﺍﺯ ﺣﺮﮐﺖ ﻭ ﺍﻓﺘﺎﺩﻥ
ﺍﯾﻦ ﻗﺴﻤﺖﻫﺎ ﺷﺎﻣﻞ ﺍﺟﺰﺍﯼ ﺯﯾﺮ ﻣﯽﺷﻮﻧﺪ:
ﻟﺮﺯﻩﮔﯿﺮﻫﺎ ﻫﻢ ﻧﺼﺐ ﻣﯽﺷﻮﺩ )ﺗﺼﻮﯾﺮ .(1
ﻓﻦ ﺍﺯ ﺭﻭﯼ ﺗﮑﯿﻪﮔﺎﻩ ﻫﻨﮕﺎﻡ ﺯﻟﺰﻟﻪ ﻣﯽﺷﻮﻧﺪ.
ﻟﺮﺯﻩﮔﯿﺮ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺗﺠﻬﻴﺰﺍﺕ ﺟﺎﻧﺒﻰ ﻓﻦ
ﯾﮏ ﭘﺎﯾﻪ ﻓﻠﺰﯼ ﻟﺮﺯﻩﮔﯿﺮ ﺭﺍ ﺩﺭ ﺑﺮ ﻣﯽﮔﯿﺮﺩ؛
ﺣﻔﺎﻅ ﺗﺴﻤﻪﻫﺎ
ﺍﻣــﺎ ﺍﯾﻦ ﭘﺎﯾﻪ ﺑﺎ ﺗﮑﯿﻪﮔﺎﻩ ﻓﻦ ﺗﻤﺎﺱ ﻧﺪﺍﺭﺩ ﺗﺎ
ﺭﯾﻞﻫﺎﯼ ﺟﺎﻧﺒﯽ
ﺍﺭﺗﻌﺎﺵ ﺑﻪ ﺩﺍﺧﻞ ﺳﺎﺧﺘﻤﺎﻥ ﺳﺮﺍﯾﺖ ﻧﮑﻨﺪ.
ﭘﺮﻩﻫﺎﯼ ﺩﺍﺧﻠﯽ ﻭ ﺩﻣﭙﺮﻫﺎﯼ ﺧﺎﺭﺟﯽ
ﻟﺮﺯﻩﮔﯿﺮﻫﺎ ﺑﺮﺍﯼ ﻓﻦﻫﺎﯼ ﺑﺰﺭﮒ ﺑﺎ ﻣﺼﺎﺭﻑ
ﺳﯿﺴﺘﻢﻫﺎﯼ ﺭﺍﻧﺶ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ
ﻏﯿﺮﺧﺎﻧﮕﯽ ﻓﻨﺮﻫﺎﯾﯽ ﻫﺴﺘﻨﺪ ﮐﻪ ﺯﯾﺮ ﺻﻔﺤﺎﺕ
ﺻﺪﺍﮔﯿﺮﻫﺎ
ﻧﺒﺸــﯽﻫﺎﯼ ﻗﻮﯼ ﺁﻫﻨﯽ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﻧﺪ .ﺍﯾﻦ ﻟﺮﺯﻩﮔﯿﺮﻫﺎ ﺍﺯ ﻟﺮﺯﻩﮔﯿﺮﻫﺎﯼ ﻧﻮﻉ ﺧﺎﻧﮕﯽ ﻭﺯﻥ
ﻟﺮﺯﻩﮔﯿﺮ ﻫﺮ ﺍﻧــﺪﺍﺯﻩ ﮐﻪ ﻓﻦ ﻭ ﻣﻮﺗﻮﺭ ﺧﻮﺏ ﻧﺼﺐ ﺷــﻮﻧﺪ ،ﻫﻤﯿﺸــﻪ ﻣﻘﺪﺍﺭﯼ ﺍﺭﺗﻌﺎﺵ ﻭﺟﻮﺩ
ﻣﺘﺼﻞﮐﻨﻨﺪﻩﻫﺎﯼ ﺍﻧﻌﻄﺎﻑﭘﺬﯾﺮ ﺍﮔﺮ ﺧﺮﻭﺟﯽ ﻓﻦ ﻣﺴﺘﻘﯿﻤﺎ ﺑﻪ ﺳﯿﺴﺘﻢ ﮐﺎﻧﺎﻝ ﻣﺘﺼﻞ ﺷــﻮﻧﺪ ،ﺍﺭﺗﻌﺎﺵ ﻓﻦ ﻭ ﻣﻮﺗﻮﺭ ﺗﻮﺳــﻂ ﮐﺎﻧﺎﻝ ﺑﻪ ﺩﺍﺧﻞ ﺳﺎﺧﺘﻤﺎﻥ ﻣﻨﺘﻘﻞ ﻣﯽﺷﻮﺩ .ﺑﺮﺍﯼ ﺟﻠﻮﮔﯿﺮﯼ ﺍﺯ ﺍﯾﻦ ﺍﺗﻔﺎﻕ ،ﻋﻤﻮﻣﺎ ﻓﻦ ﺭﺍ ﺗﻮﺳــﻂ ﺍﺗﺼﺎﻝ ﺩﻫﻨــﺪﻩ ﺍﻧﻌﻄﺎﻑﭘﺬﯾﺮ ﺑﻪ ﮐﺎﻧﺎﻝ ﻣﺘﺼــﻞ ﻣﯽﮐﻨﻨﺪ )ﺗﺼﻮﯾﺮ .(4ﺍﯾﻦ
ﺑﯿﺸﺘﺮﯼ ﺭﺍ ﺗﺤﻤﻞ ﻣﯽﮐﻨﻨﺪ.
ﻣﺎﺩﻩ ،ﺍﺗﺼﺎﻟﯽ ﻏﯿﺮﻗﺎﺑﻞ ﻧﻔﻮﺫ ﺑﺮﺍﯼ ﻫﻮﺍ ﺍﯾﺠﺎﺩ
ﺷﺎﺳﯽ
ﻣﯽﮐﻨﺪ ﻭ ﮐﺎﻧﺎﻝ ﻫﯿﭻ ﺍﺭﺗﻌﺎﺷــﯽ ﺭﺍ ﻣﻨﺘﻘﻞ ﻧﻤﯽﮐﻨﺪ.
ﺩﺍﺭﺩ .ﺍﮔﺮ ﺍﯾﻦ ﺍﺭﺗﻌﺎﺵ ﺍﺯ ﻓﻦ ﺣﺬﻑ ﻧﺸــﻮﺩ،
ﺑﺮﺍﯼ ﻣﺠﻤﻮﻋﻪﻫﺎﯼ ﺑﺰﺭﮒ ،ﻓﻦ ﻭ ﻣﻮﺗﻮﺭ
ﺑﻪ ﺩﺍﺧﻞ ﺳﺎﺧﺘﻤﺎﻥ ﻭ ﺷﺒﮑﻪ ﮐﺎﻧﺎﻝ ﺳﺮﺍﯾﺖ
ﻣﺴﺘﻘﯿﻤﺎ ﺭﻭﯼ ﯾﮏ ﺷﺎﺳﯽ ﻧﺼﺐ ﻣﯽﺷﻮﻧﺪ.
ﺑﯿﺸﺘﺮ ﻣﺘﺼﻞﮐﻨﻨﺪﻩﻫﺎﯼ ﺍﻧﻌﻄﺎﻑﭘﺬﯾﺮ
ﻣﯽﮐﻨﺪ ﻭ ﺳﯿﺴﺘﻢ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺭﺍ ﻏﯿﺮﻗﺎﺑﻞ
ﮐــﻪ ﺑﻪ ﺁﻥ ﺑﻠﻮﮎ ﺍﯾﻨﺮﺳــﯽ ﻫــﻢ ﻣﯽﮔﻮﯾﻨﺪ
ﺩﺍﺭﺍﯼ ﻭﺭﻕﻫــﺎﯼ ﻓﻠــﺰﯼ ﻫﺴــﺘﻨﺪ ﮐــﻪ ﺑﻪ
ﻗﺒﻮﻝ ﻣﯽﺳﺎﺯﺩ.
)ﺗﺼﻮﯾﺮ .(3ﺷﺎﺳﯽ ﯾﮏ ﺩﺍﻝ ﺳﯿﻤﺎﻧﯽ ﺍﺳﺖ
ﺩﻭﻃﺮﻑ ﻣﺎﺩﻩ ﺍﻧﻌﻄﺎﻑﭘﺬﯾﺮ ﻣﺘﺼﻞ ﺷﺪﻩﺍﻧﺪ.
ﺑﺮﺍﯼ ﺟﺬﺏ ﺍﺭﺗﻌــﺎﺵ ﺗﺠﻬﯿﺰﺍﺗﯽ ﻭﺟﻮﺩ
ﮐــﻪ ﺭﻭﯼ ﻓﻨﺮﻫﺎﯼ ﻟﻮﻝ ﻗﻮﯼ ﺑﻪ ﺯﻣﯿﻦ ﻭﺻﻞ
ﺍﯾﻦ ﻭﺭﻕ ﻓﻠﺰﯼ ﺑﻪ ﺍﻧﺪﺍﺯﻩ ﺧﺮﻭﺟﯽ ﻓﻦ ﺑﺮﯾﺪﻩ
ﺩﺍﺭﻧﺪ) .ﻣﻨﻈﻮﺭ ﺍﺯ ﺟﺬﺏ ﺍﺭﺗﻌﺎﺵ ،ﮐﺎﻫﺶ ﯾﺎ
ﻣﯽﺷــﻮﺩ )ﺗﺼﻮﯾــﺮ .(3ﻭﺯﻥ ﺯﯾﺎﺩ ﺍﯾﻦ ﻗﻄﻌﻪ
ﻭ ﺍﻧﺪﺍﺯﻩ ﻣﯽﺷﻮﺩ .ﺍﻏﻠﺐ ﻣﺘﺼﻞﮐﻨﻨﺪﻩﻫﺎﯼ
ﺍﺯ ﺑﯿﻦ ﺑﺮﺩﻥ ﺍﺭﺗﻌﺎﺵ ﺍﺳﺖ(.
ﺍﺭﺗﻌﺎﺵ ﻓﻦ ﻭ ﻣﻮﺗﻮﺭ ﺭﺍ ﺟﺬﺏ ﻣﯽﮐﻨﺪ ،ﻓﻨﺮﻫﺎ
ﺍﻧﻌﻄﺎﻑﭘﺬﯾﺮ ﺧﺮﯾﺪﺍﺭﯼ ﻭ ﺑﻪ ﺍﻧﺪﺍﺯﻩ ﻣﻮﺭﺩ ﻧﻈﺮ ﺑﺮﯾﺪﻩ ﻣﯽﺷﻮﻧﺪ.
ﻟﺮﺯﻩﮔﯿﺮﻫــﺎ ﻣﯽﺗﻮﺍﻧﻨﺪ ﻓﻨــﺮ ﯾﺎ ﻗﻄﻌﺎﺕ
ﻫﺮﮔﻮﻧﻪ ﺍﺭﺗﻌﺎﺵ ﺑﺎﻗﯽﻣﺎﻧﺪﻩ ﺭﺍ ﺩﻓﻊ ﻣﯽﮐﻨﻨﺪ
ﻻﺳﺘﯿﮑﯽ ﺑﺎﺷﻨﺪ ﮐﻪ ﺍﺯ ﺳﺮﺍﯾﺖﮐﺮﺩﻥ ﺍﺭﺗﻌﺎﺵ
ﺗﺎ ﻫﯿﭻ ﺍﺭﺗﻌﺎﺷﯽ ﺑﻪ ﺳﺎﺧﺘﻤﺎﻥ ﻣﻨﺘﻘﻞ ﻧﺸﻮﺩ.
ﺑﻪ ﺩﺍﺧﻞ ﺳــﺎﺧﺘﻤﺎﻥ ﺟﻠﻮﮔﯿﺮﯼ ﻣﯽﮐﻨﻨﺪ.
ﻣﻤﮑﻦ ﺍﺳــﺖ ﻻﺯﻡ ﺑﺎﺷﺪ ﮐﺸــﺶ ﻓﻨﺮﻫﺎ ﺭﺍ
ﻫﺮ ﺗﺴﻤﻪ ﻓﻦ ﺑﺎﯾﺪ ﺣﻔﺎﻅ ﺗﺴﻤﻪ ﺩﺍﺷﺘﻪ
ﺑﻌﻀﯽ ﺍﺯ ﻟﺮﺯﻩﮔﯿﺮﻫﺎ ﻗﻄﻌﺎﺕ ﻣﮑﻌﺐﺷــﮑﻞ
ﺗﻨﻈﯿﻢ ﮐﺮﺩ؛ ﺯﯾﺮﺍ ﺩﺭ ﻧﻘﺎﻁ ﻣﺸﺨﺼﯽ ﻣﻤﮑﻦ
ﺑﺎﺷــﺪ ﺗﺎ ﻫﻤﻪ ﻗﻄﻌﺎﺕ ﻣﺘﺤﺮﮎ ﺳﯿﺴــﺘﻢ
ﻻﺳﺘﯿﮑﯽ ﻫﺴﺘﻨﺪ ﮐﻪ ﭘﯿﭻﻫﺎﯼ ﻧﺼﺐ ﺩﺍﺧﻞ
ﺍﺳﺖ ﻓﺸﺮﺩﮔﯽ ﺑﯿﺸــﺘﺮﯼ ﻻﺯﻡ ﺑﺎﺷﺪ )ﻣﺜﻼ
ﺭﺍﻧﺶ ﺭﺍ ﭘﻮﺷــﺶ ﺩﻫﺪ )ﺗﺼﻮﯾــﺮ .(5ﺣﻔﺎﻅ
ﺁﻥﻫﺎ ﺟﺎﯼ ﻣﯽﮔﯿﺮﻧﺪ ﻭ ﺑﺮﺍﯼ ﻓﻦﻫﺎﯼ ﮐﻮﭼﮏ
ﺯﯾﺮ ﻣﻮﺗﻮﺭ( .ﺍﮔﺮ ﺷﺎﺳــﯽ ﻣﺴﺘﻘﯿﻤﺎ ﺑﻪ ﺯﻣﯿﻦ
ﺗﺴﻤﻪ ﺗﺎ ﺣﺪﻭﺩﯼ ﺍﺯ ﺭﺳﯿﺪﻥ ﻫﻮﺍ ﺑﻪ ﻭﺭﻭﺩﯼ
ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷــﻮﻧﺪ .ﻣﺜﻼ ﺩﺍﺧﻞ ﮐﻮﺭﻩﻫﺎﯼ
ﻣﺘﺼﻞ ﺷﻮﺩ ،ﺍﺯ ﻓﻨﺮ ﺍﺳﺘﻔﺎﺩﻩ ﻧﻤﯽﺷﻮﺩ؛ ﺯﯾﺮﺍ
ﻓﻦ ﻣﻤﺎﻧﻌﺖ ﻣﯽﮐﻨــﺪ ﻭ ﺩﺭﻧﺘﯿﺠﻪ ﻣﻘﺪﺍﺭﯼ
ﺧﺎﻧﮕــﯽ .ﻣﻮﺗﻮﺭ ﻓــﻦ ﺭﻭﯼ ﭘﺎﯾــﻪﺍﯼ ﻧﺼﺐ
ﺯﻣﯿﻦ ﺍﺭﺗﻌﺎﺵ ﺭﺍ ﺟﺬﺏ ﻣﯽﮐﻨﺪ.
ﺍﺛﺮ ﺳﯿﺴــﺘﻢ ﺩﺍﺭﺩ .ﺟﻠﻮﯼ ﺣﻔــﺎﻅ ﺑﺎﯾﺪ ﺑﻪ
ﻣﯽﺷﻮﺩ ﮐﻪ ﺭﻭﯼ ﻣﺤﻔﻈﻪ ﻓﻦ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ. ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺩﺭ ﻣﻨﺎﻃﻖ ﺯﻟﺰﻟﻪﺧﯿــﺰ ،ﻓﻦﻫﺎﯼ ﺑﺰﺭﮒ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﺣﻔﺎﻅ ﺗﺴﻤﻪ
ﺻﻮﺭﺕ ﺷــﺒﮑﻪ ﺳﺎﺧﺘﻪ ﺷــﻮﺩ ﺗﺎ ﺑﯿﺸﺘﺮﯾﻦ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 35ﺷﻤﺎﺭﻩ 30
ﻣﻮﺗﻮﺭ ﺗﻜﻪ ﻻﺳﺘﻴﻜﻰ
ﭘﻴﭻ ﺗﻨﻄﻴﻢ
ﭘﻴﭻ
ﻗﺎﺏ ﻓﻠﺰﻯ
ﺗﻨﻬﺎ ﮐﺴــﯽ ﻫﺴﺘﯿﺪ ﮐﻪ ﺑﺎ ﻓﻦ ﮐﺎﺭ ﻣﯽﮐﻨﯿﺪ ﻣﻤﮑﻦ ﺍﺳــﺖ ﺑﯽﺍﺣﺘﯿﺎﻃﯽ ﮐﻨﯿﺪ ﻭ ﺗﻮﺳﻂ ﺗﺴــﻤﻪﻫﺎ ﯾﺎ ﭘﻮﻟﯽ ﺻﺪﻣﻪ ﺑﺒﯿﻨﯿﺪ .ﺗﺴﻤﻪ ﺩﺭ
ﻟﺮﺯﻩﮔﻴﺮ
ﻗﺎﺏ ﺁﻫﻨﻰ
ﺣﺎﻝ ﮐﺎﺭ ﺑــﺪﻭﻥ ﺣﻔﺎﻅ ﺑﺮﺍﯼ ﺩﯾﮕﺮ ﮐﺎﺭﮔﺮﺍﻥ ﻫﻢ ﺧﻄﺮﻧﺎﮎ ﺍﺳﺖ؛ ﺯﯾﺮﺍ ﺁﻥﻫﺎ ﻓﮑﺮ ﻣﯽﮐﻨﻨﺪ ﮐﻪ ﺣﻔﺎﻅ ﺳــﺮ ﺟﺎﯼ ﺧﻮﺩ ﺍﺳﺖ ﻭ ﺑﻪﺭﺍﺣﺘﯽ ﻣﻤﮑﻦ ﺍﺳﺖ ﺻﺪﻣﻪ ﺑﺒﯿﻨﻨﺪ .ﺩﺭ ﯾﮏ ﻣﻮﺭﺩ، ﮐﺎﺭﮔﺮ ﺩﺭ ﺣﺎﻟﯽ ﺩﺍﺧﻞ ﭘﻠﻨﻮﻡ ﻓﻦ ﺭﻓﺘﻪ ﺑﻮﺩ ﮐﻪ
ﺗﺼﻮﻳﺮ ) (1ﻟﺮﺯﻩﮔﻴﺮﻫﺎ ﺭﻭﻯ ﻗﺎﺏ ﻣﻮﺗﻮﺭ ﻭ ﺗﻜﻴﻪﮔﺎﻩ ﻓﻦ ﺑﻪ ﻛﺎﺭ ﻣﻰﺭﻭﻧﺪ.
ﺣﻔﺎﻁ ﻓﻦ ﺳــﺮ ﺟﺎﯾﺶ ﻧﺒﻮﺩ ﻭ ﺍﻧﮕﺸﺘﺎﻥ ﺍﻭ ﺑﯿﻦ ﺗﺴﻤﻪ ﻭ ﭘﻮﻟﯽ ﮔﯿﺮ ﮐﺮﺩ.
ﺭﯾﻞﻫﺎﯼ ﮐﺸﻮﯾﯽ ﻓﻨﺮﻫﺎﻯ ﻟﺮﺯﻩﮔﻴﺮ ﻓﻨﺮ ﺗﻜﻴﻪﮔﺎﻩ
ﻗﺎﺏ ﺁﻫﻨﻰ
ﺭﯾﻞﻫﺎﯼ ﮐﺸــﻮﯾﯽ ﻧﺸﺎﻥﺩﺍﺩﻩﺷــﺪﻩ ﺩﺭ ﺗﺼﻮﯾﺮ ) (6ﻗﺴﻤﺘﯽ ﺍﺯ ﺗﮑﯿﻪﮔﺎﻩ ﻣﻮﺗﻮﺭ ﻫﺴﺘﻨﺪ ﮐﻪ ﺑﻪ ﺁﻥ ﺍﺟﺎﺯﻩ ﻣﯽﺩﻫﻨﺪ ﺟﻠﻮ ﻭ ﻋﻘﺐ ﺑﺮﻭﺩ
ﺯﻣﻴﻦ
ﺗﺎ ﺑﺘﻮﺍﻥ ﮐﺸﺶ ﺗﺴﻤﻪ ﺭﺍ ﺗﻨﻈﯿﻢ ﮐﺮﺩ .ﺭﯾﻞﻫﺎ
ﻣﻮﺗﻮﺭ ﺟﻬﺖ ﺗﻨﻈﯿﻢ ﮐﺸــﺶ ﺗﺴــﻤﻪ ،ﺑﺎﯾﺪ ﭘﯿﭻﻫﺎﯼ ﻣﻮﺗﻮﺭ ﺭﺍ ﺷﻞ ﮐﺮﺩ ،ﻃﻮﺭﯼ ﮐﻪ ﺑﺘﻮﺍﻥ ﺁﻥ ﺭﺍ ﺣﺮﮐﺖ ﺩﺍﺩ .ﺭﻭﯼ ﺑﯿﺸﺘﺮ ﺗﮑﯿﻪﮔﺎﻩﻫﺎﯼ ﻣﻮﺗﻮﺭ ﭘﯿﭻ ﺗﻨﻈﯿﻢ ﮐﺸــﺶ ﻧﺸﺎﻥﺩﺍﺩﻩﺷﺪﻩ
ﺷﺎﺳﻰ
ﻓﻨﺮ ﻋﺎﻳﻖﻛﻨﻨﺪﻩ ﺯﻣﻴﻦ
ﺩﺭ ﺗﺼﻮﯾــﺮ ) (6ﻭﺟﻮﺩ ﺩﺍﺭﺩ ﺗﺎ ﺑﺘﻮﺍﻥ ﻣﻮﺗﻮﺭ ﺭﺍ ﺑﺮﺍﯼ ﺑﻪ ﺩﺳــﺖ ﺁﻭﺭﺩﻥ ﮐﺸــﺶ ﻣﻨﺎﺳﺐ ﺩﺭ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﺼﻮﻳﺮ )(2
ﭘﺎﯾﻪﻫﺎ ﭘﯿﭻ ﻣﯽﺷــﻮﺩ .ﺑــﺮﺍﯼ ﺣﺮﮐﺖ ﺩﺍﺩﻥ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﺑﻪ ﭘﺎﯾﻪ ﭘﯿﭻ ﻣﯽﺷــﻮﻧﺪ ﻭ ﻣﻮﺗﻮﺭ ﻣﺴﺘﻘﯿﻤﺎ ﺑﻪ
ﺗﺴﻤﻪ ﺟﻠﻮ ﻭ ﻋﻘﺐ ﮐﺮﺩ ﻭ ﺟﻬﺖ ﺗﺴﻤﻪﻫﺎﯼ
ﺗﺼﻮﻳﺮ ) (3ﺷﺎﺳﻰ ﺭﻭﻯ ﻓﻨﺮﻫﺎ ﻗﺮﺍﺭ ﻣﻰﮔﻴﺮﺩ.
Vﺷــﮑﻞ ﺭﺍ ﺗﻨﻈﯿﻢ ﻧﻤﻮﺩ ،ﺳﭙﺲ ﭘﯿﭻﻫﺎﯼ ﻣﻮﺗﻮﺭ ﺩﻭﺑﺎﺭﻩ ﺳﻔﺖ ﻣﯽﺷﻮﻧﺪ )ﺗﺼﻮﯾﺮ .(7
ﻛﺎﻧﺎﻝ
ﺑﺎ ﺁﻥ ﭘﯿﭻ ﻣﻮﺗﻮﺭ ﺭﺍ ﻋﻘﺐ ﺑﮑﺸﯿﺪ .ﭘﯿﭽﯽ ﮐﻪ
ﻛﺎﻧﺎﻝ
ﭘﯿﭻ ﺗﻨﻈﯿﻢ ﺭﺍ ﺳﻔﺖ ﮐﻨﯿﺪ .ﺳﭙﺲ ﻣﻮﺗﻮﺭ ﺭﺍ ﺑﭽﺮﺧﺎﻧﯿﺪ ﺗﺎ ﺗﻨﻈﯿﻢ ﺗﺴــﻤﻪ Vﺷﮑﻞ ﺍﻧﺠﺎﻡ ﺷﻮﺩ .ﺳﭙﺲ ﻫﻤﻪ ﭘﯿﭻﻫﺎ ﺭﺍ ﺳﻔﺖ ﮐﻨﯿﺪ.
ﺗﻠﻔﻦ55401278 :
ﻣﻮﺗﻮﺭ ﺭﺍ ﺑﻪ ﺭﯾﻞ ﻣﺘﺼﻞ ﻣﯽﮐﻨﺪ ﺳﻔﺖ ﮐﻨﯿﺪ.
ﺭﯾﻞﻫﺎﯼ ﮐﺸــﻮﯾﯽ ﺑﺎﯾﺪ ﺑﻪ ﺷﺎﺳﯽ ﭘﯿﭻ ﺷﻮﻧﺪ ،ﺑﻪ ﺻﻮﺭﺗﯽ ﮐﻪ ﺩﻗﯿﻘﺎ ﻣﻮﺍﺯﯼ ﭘﺎﯾﻪ ﻓﻦ
ﺗﺼﻮﻳﺮ ) (4ﺍﺗﺼﺎﻝﺩﻫﻨﺪﻩ ﺍﻧﻌﻄﺎﻑﭘﺬﻳﺮ
ﺗﺼﻮﻳﺮ ) (5ﺣﻔﺎﻅ ﺗﺴﻤﻪ
ﻫﻮﺍﯼ ﻣﻤﮑﻦ ﺭﺍ ﻋﺒﻮﺭ ﺩﻫﺪ .ﭘﺎﯾﻪﻫﺎﯼ ﻓﻠﺰﯼ
ﻣﯽﺷــﻮﺩ .ﻏﯿﺮ ﺍﺯ ﻣﻮﺍﻗﻊ ﻧﺎﭼﺎﺭﯼ ﺍﺯ ﺭﻭﺷــﻦ
ﻣﻮﺗــﻮﺭ ﺑﺎﯾﺪ ﻋﻤــﻮﺩ ﺑﺮ ﺭﯾﻞﻫﺎ ﺑﺎﺷــﺪ .ﺑﺮﺍﯼ
ﺣﻔــﺎﻅ ﺭﺍ ﻣﺤﮑﻢ ﺑﻪ ﻣﻮﺗــﻮﺭ ﻭ ﻓﻦ ﻣﺘﺼﻞ
ﮐﺮﺩﻥ ﺳﯿﺴــﺘﻢ ﺩﺭ ﻫﻨﮕﺎﻡ ﺑﺎﺯ ﺑﻮﺩﻥ ﺣﻔﺎﻅ
ﺑﺮﺭﺳــﯽ ﺍﯾﻦ ﺍﻣﺮ ﺑﺎﯾﺪ ﻓﺎﺻﻠﻪ ﻫﺮ ﺩﻭ ﺍﻧﺘﻬﺎﯼ
ﻣﯽﮐﻨﻨﺪ .ﺣﻔﺎﻅ ﺗﺴــﻤﻪ ﺑﺮﺍﯼ ﺍﯾﻤﻨﯽ ﻧﺼﺐ
ﺗﺴــﻤﻪ ،ﺧــﻮﺩﺩﺍﺭﯼ ﮐﻨﯿﺪ .ﺣﺘﺎ ﺍﮔﺮ ﺷــﻤﺎ
ﭘﺎﯾﻪ ﻣﻮﺗﻮﺭ ﺭﺍ ﺍﺯ ﺭﯾﻞ ﺍﻧﺪﺍﺯﻩ ﮔﺮﻓﺖ ،ﺍﮔﺮ ﺍﯾﻦ ﺩﻭ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺑﺎﺷﻨﺪ .ﺑﻌﺪ ﺍﺯ ﺗﻨﻈﯿﻢ ﮐﺸﺶ ﺗﺴﻤﻪ ،ﻣﺤﻮﺭ
Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻣﺎﺩﻩ ﺍﻧﻌﻄﺎﻑﭘﺬﻳﺮ
ﺍﮔﺮ ﻓﻘــﻂ ﯾﮏ ﭘﯿﭻ ﺗﻨﻈﯿﻢ ﻭﺟﻮﺩ ﺩﺍﺭﺩ،
ﺻﻔﺤﻪ / 36ﺷﻤﺎﺭﻩ 30
ﻓﻦ ﺭﺍ ﺍﻓﺰﺍﯾﺶ ﻣﯽﺩﻫﻨﺪ .ﺩﻣﭙﺮﻫﺎﯼ ﺧﺮﻭﺟﯽ ﺑﻪ ﺍﻧﺪﺍﺯﻩ ﭘﺮﻩﻫــﺎﯼ ﺩﺍﺧﻠﯽ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺭﺍ ﮐﺎﻫﺶ ﻧﻤﯽﺩﻫﻨﺪ؛ ﺍﻣﺎ ﺑﻪ ﺧﺎﻃﺮ ﻫﺰﯾﻨﻪ ﻧﺼﺐ ﮐﻤﺘﺮ ﻣﻌﻤﻮﻻ ﺍﺯ ﺁﻥﻫﺎ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ. ﺩﻭ ﻧــﻮﻉ ﺩﻣﭙﺮ ﻭﺟﻮﺩ ﺩﺍﺭﺩ .ﺗﯿﻐﻪﻣﺘﻘﺎﺑﻞ
ﺭﻳﻞ ﻛﺸﻮﻳﻰ
ﻭ ﺗﯿﻐﻪﻣــﻮﺍﺯﯼ )ﺗﺼﻮﯾــﺮ .(9ﺩﻣﭙﺮ ﺧﺮﻭﺟﯽ
ﭘﻴﭻ ﺗﻨﻈﻴﻢ
ﻓــﻦ ﺑﺎﯾﺪ ﺍﺯ ﻧﻮﻉ ﺗﯿﻐﻪ ﻣﺘﻘﺎﺑﻞ ﺑﺎﺷــﻨﺪ .ﺍﯾﻦ
ﺗﺼﻮﻳﺮ) (6ﺭﻳﻞ ﻟﻐﺰﺷﻰ ﻭ ﭘﻴﭻﻫﺎﻯ ﺗﻨﻈﻴﻢ ﻛﺸﺶ ﺑﺮﺍﻯ ﻣﻮﺗﻮﺭ
ﺗﺼﻮﻳﺮ) (7ﺳﻔﺖﻛﺮﺩﻥﭘﻴﭻﻫﺎﻯﻣﻮﺗﻮﺭ
ﺩﻣﭙﺮﻫﺎ ﻫﻮﺍ ﺭﺍ ﺑﻬﺘﺮ ﻣﺴﺪﻭﺩ ﻣﯽﮐﻨﻨﺪ ﻭ ﺗﻮﺯﯾﻊ ﻫﻮﺍﯼ ﯾﮏﻧﻮﺍﺧﺖﺗﺮﯼ ﺩﺍﺧﻞ ﮐﺎﻧﺎﻝ ﺑﻪ ﻭﺟﻮﺩ ﻣﯽﺁﻭﺭﻧﺪ.
ﺳﯿﺴﺘﻢﻫﺎﯼ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ ﯾﮏ ﺳﯿﺴــﺘﻢ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ )(VFD ﺑــﺮﺍﯼ ﮐﻨﺘﺮﻝ ﺳــﺮﻋﺖ ﻣﺘﻐﯿﺮ ﻓــﻦ ﺑﻪ ﮐﺎﺭ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﻣﯽﺭﻭﺩ VFD .ﺍﺑﺰﺍﺭﯼ ﺍﻟﮑﺘﺮﻭﻧﯿﮑﯽ ﺍﺳﺖ ﮐﻪ ﺩﻣﭙﺮ ﺗﻴﻐﻪ ﻣﺘﻘﺎﺑﻞ ﺗﺼﻮﻳﺮ ) (8ﭘﺮﻩﻫﺎﻯ ﻭﺭﻭﺩﻯ
ﺗﺼﻮﻳﺮ) (9ﺩﻣﭙﺮﻫﺎ ﻣﻤﻜﻦ ﺍﺳﺖ ﺗﻴﻐﻪﻫﺎﻯ ﻣﻮﺍﺯﻯ ﻳﺎ ﻣﺘﻘﺎﺑﻞ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻨﺪ.
ﻓﺎﺻﻠﻪ ﺑﺮﺍﺑﺮ ﺑﺎﺷﻨﺪ ،ﻣﺤﻮﺭ ﻣﻮﺗﻮﺭ ﻭ ﺭﯾﻞ ﺑﺮ ﻫﻢ
ﮐﺎﻣﻼ ﺑﺎﺯ ﺑﺎﺷــﻨﺪ ،ﺍﺛﺮ ﺳﯿﺴﺘﻢ ﻣﻨﻔﯽ ﺍﯾﺠﺎﺩ
ﻋﻤﻮﺩ ﻫﺴﺘﻨﺪ.
ﻣﯽﮐﻨﻨــﺪ ﮐﻪ ﻃﺮﺍﺡ ﺳﯿﺴــﺘﻢ ﺑﺎﯾﺪ ﺩﺭ ﻧﻈﺮ ﺑﮕﯿﺮﺩ.
ﮐﻨﺘﺮﻝﮐﻨﻨﺪﻩﻫﺎﯼﻫﻮﺍ ﺑﺎ ﺗﻐﯿﺮ ﺳــﺮﻋﺖ ﻓــﻦ ﻣﯽﺗﻮﺍﻥ ﻓﺸــﺎﺭ ﺭﺍ ﻣﯽﺗﻮﺍﻥ ﺑﺎ ﺗﻐﯿﯿﺮ ﺗﺴــﻤﻪﻫﺎ ﯾﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺍﯾﻦ ﻭﺳﯿﻠﻪ ﺑﺎ ﺗﻐﯿﯿﺮ ﻓﺮﮐﺎﻧﺲ ﺗﻮﺍﻥ ﺍﻟﮑﺘﺮﯾﮑﯽ ﮐﻪ ﺑﻪ ﻣﻮﺗﻮﺭ ﻣﯽﺭﺳﺪ ،ﺳﺮﻋﺖ ﺁﻥ ﺭﺍ ﮐﻨﺘﺮﻝ ﻣﯽﮐﻨﺪ VFD .ﺑﺎ ﭘﻮﻟﯽ ﮔﺎﻡ ﻣﺘﻐﯿﺮ ﮐﻪ ﺳﺮﻋﺖ ﺗﺴﻤﻪ ﺭﺍ ﺗﻐﯿﯿﺮ ﻣﯽﺩﻫﺪ ،ﺗﻔﺎﻭﺕ ﺩﺍﺭﺩ.
ﻫــﻮﺍﯼ ﺩﺍﺧﻞ ﮐﺎﻧﺎﻝ ﺭﺍ ﮐﻨﺘﺮﻝ ﮐﺮﺩ .ﺍﯾﻦ ﮐﺎﺭ ) VFDﺳﯿﺴــﺘﻢ ﺭﺍﻧــﺶ ﻓﺮﮐﺎﻧﺲ ﻣﺘﻐﯿﺮ(
ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ ﺳــﯿﮕﻨﺎﻟﯽ ﮐــﻪ ﺍﺯ ﯾﮏ ﻣﻨﺒــﻊ ﺧﺎﺭﺟــﯽ ﻣﯽﺁﯾــﺪ VFD ،ﻓﺮﮐﺎﻧﺲ ﺟﺮﯾﺎﻥ ﺍﺭﺳــﺎﻟﯽ ﺑﻪ ﻣﻮﺗﻮﺭ ﺭﺍ ﺗﻐﯿﯿﺮ ﻣﯽﺩﻫﺪ.
ﺍﺯ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺭﺍﯾﺞ ﭘﺮﻩﻫﺎﯼ ﻭﺭﻭﺩﯼ ﻓﻦ،
ﺗﻐﯿﯿﺮ ﺩﺭ ﻓﺮﮐﺎﻧﺲ ﻣﻮﺟﺐ ﺗﻐﯿﯿﺮ ﺩﻭﺭ ﻣﻮﺗﻮﺭ
ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺣﺠﻢ ﻫﻮﺍ ﻣﺘﻐﯿــﺮ )(VAV
ﻭ ﺩﺭﻧﺘﯿﺠﻪ ﺗﻐﯿﯿﺮ ﺳــﺮﻋﺖ ﻓﻦ ﻣﯽﺷﻮﺩ .ﺩﺭ
ﻫﺴﺘﻨﺪ .ﯾﮏ ﺣﺴﮕﺮ ﻓﺸــﺎﺭ ﺍﺳﺘﺎﺗﯿﮏ SP
ﺁﻣﺮﯾﮑﺎ ،ﻓﺮﮐﺎﻧﺲ ﻣﻌﻤﻮﻟﯽ ﺟﺮﯾﺎﻥ ﻣﻮﺗﻮﺭ 60
ﺩﺭ ﮐﺎﻧــﺎﻝ ﻣﻨﺒﻊ ﻫﻮﺍ ،ﺳــﯿﮕﻨﺎﻝﻫﺎﯾﯽ ﺭﺍ ﺑﻪ
ﻫﺮﺗﺰ ﺍﺳﺖ.
ﮐﻨﺘﺮﻝﮐﻨﻨﺪﻩ ﻣﯽﺭﺳﺎﻧﺪ ﮐﻪ ﭘﺮﻩﻫﺎ ﺭﺍ ﺑﻪ ﺍﻧﺪﺍﺯﻩ
ﺍﻧﺠﺎﻡ ﺩﺍﺩ. ﺗﻠﻔﻦ88739880-2:
ﺩﻣﭙﺮ ﺗﻴﻐﻪ ﻣﻮﺍﺯﻯ
ﺩﺍﺧﻞ ﻣﺤﻔﻈﻪﺍﯼ ﻗﺮﺍﺭ ﻣﯽﮔﯿﺮﺩ )ﺗﺼﻮﯾﺮ .(10
VFDﻣﯽﺗﻮﺍﻧــﺪ ﻓﺮﮐﺎﻧﺲ ﺭﺍ ﺑﯿﻦ 12ﺗﺎ 60ﻫﺮﺗﺰ ﺗﻐﯿﯿﺮ ﺩﻫﺪ.
ﻓﺸــﺎﺭ ﻫــﻮﺍ ﺭﺍ ﻣﯽﺗﻮﺍﻥ ﺑﺎ ﺍﺳــﺘﻔﺎﺩﻩ ﺍﺯ
ﮐﺎﻓﯽ ﺑﺎﺯ ﯾﺎ ﺑﺴﺘﻪ ﻣﯽﮐﻨﺪ ﺗﺎ ﻓﺸﺎﺭ ﺍﺳﺘﺎﺗﯿﮏ
ﺩﻣﭙﺮﻫﺎﯼ ﺧﺮﻭﺟﯽ ﯾﺎ ﭘﺮﻩﻫﺎﯼ ﻭﺭﻭﺩﯼ ﺩﺍﺧﻞ
ﻣﻄﻠﻮﺏ ﺩﺭ ﺳﯿﺴــﺘﻢ ﺍﯾﺠﺎﺩ ﺷﻮﺩ .ﭘﺮﻩﻫﺎﯼ
ﻣﻮﺗﻮﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺑﺎ ﯾﮏ VFDﺑﺎﯾﺪ
ﻓﻦ ﮐﻨﺘﺮﻝ ﮐﺮﺩ ،ﺍﻣﺎ ﻣﻌﻤﻮﻻ ﺍﯾﻦ ﮐﺎﺭ ﺁﺧﺮﯼ
ﺩﻭﺭﺍﻧﯽ ﺩﺍﺧﻠﯽ ﻃﻮﺭﯼ ﻃﺮﺍﺣﯽ ﻣﯽﺷﻮﻧﺪ ﮐﻪ
ﺑﻪ ﻫﻤﺎﻥ ﻣﻨﻈﻮﺭ ﻃﺮﺍﺣﯽ ﺷــﺪﻩ ﺑﺎﺷﺪ .ﺍﮔﺮ
ﺍﺳــﺖ ﮐﻪ ﺍﻧﺘﺨﺎﺏ ﻣﯽﺷــﻮﺩ؛ ﺯﯾــﺮﺍ ﺍﻧﺮﮊﯼ
ﻫﻮﺍ ﺭﺍ ﺩﺭ ﺟﻬﺖ ﭼﺮﺧﺶ ﭘﺮﻭﺍﻧﻪ ﺑﻪ ﭼﺮﺧﺶ
ﻣﻮﺗﻮﺭ ﺑﺮﺍﯼ VFDﻃﺮﺍﺣﯽ ﻧﺸﺪﻩ ﺑﺎﺷﺪ ،ﻓﻨﯽ
ﺑﯿﺸﺘﺮﯼ ﺍﺯ ﺗﻐﯿﯿﺮ ﺗﺴﻤﻪ ﯾﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ VFD
ﺩﺭﺁﻭﺭﻧﺪ .ﺍﺧﯿﺮﺍ ﺩﺭ ﭘﺮﻭﮊﻩﻫﺎ ﺑﻪ ﺟﺎﯼ ﭘﺮﻩﻫﺎﯼ
ﮐﻪ ﻣﻮﺗﻮﺭ ﺭﺍ ﺧﻨﮏ ﻣﯽﮐﻨﺪ ﺩﺭ ﺳــﺮﻋﺖﻫﺎﯼ
ﻣﯽﺑﺮﺩ.
ﺩﺍﺧﻠﯽ ﺍﺯ ﺳﯿﺴﺘﻢ VFDﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ.
ﭘﺎﯾﯿﻦ ،ﺁﻫﺴــﺘﻪﺗﺮ ﮐﺎﺭ ﻣﯽﮐﻨــﺪ .ﺩﺭ ﻧﺘﯿﺠﻪ
ﭘﺮﻩﻫﺎﯼ ﺩﺍﺧﻠﯽ
ﺩﻣﭙﺮﻫﺎﯼ ﺧﺮﻭﺟﯽ
ﻣﻮﺗﻮﺭ ﺑﻪﻗﺪﺭ ﮐﺎﻓﯽ ﺧﻨﮏ ﻧﻤﯽﺷﻮﺩ ﻭ ﺑﯿﺶ ﺍﺯ ﺣﺪ ﮔﺮﻡ ﻣﯽﺷﻮﺩ.
ﺍﺯ ﭘﺮﻩﻫﺎﯼ ﺩﺍﺧﻠــﯽ ﺗﺼﻮﯾﺮ ) (8ﻣﯽﺗﻮﺍﻥ
ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﯾﮏ ﺩﻣﭙﺮ ﺩﺭ ﺧﺮﻭﺟﯽ ﻫﻢ
ﯾﮏ ﻣﺰﯾﺖ ﺳﯿﺴــﺘﻢ VFDﺍﯾﻦ ﺍﺳﺖ
ﺑﺮﺍﯼ ﮐﻨﺘﺮﻝ ﻫﻮﺍﯾــﯽ ﮐﻪ ﻓﻦ ﺗﻮﻟﯿﺪ ﻣﯽﮐﻨﺪ
ﻣﯽﺗــﻮﺍﻥ ﺣﺠﻢ ﻫﻮﺍﯼ ﻓــﻦ ﺭﺍ ﮐﻨﺘﺮﻝ ﮐﺮﺩ؛
ﮐﻪ ﺑﻪﺍﺯﺍﯼ ﺗﻐﯿﯿﺮﺍﺕ ﻓﺸــﺎﺭ ﺍﺳــﺘﺎﺗﯿﮏ ﺩﺭ
ﺍﺳــﺘﻔﺎﺩﻩ ﮐﺮﺩ .ﺑﺎ ﺍﯾﻦ ﻭﺟﻮﺩ ﺣﺘﺎ ﺍﮔﺮ ﭘﺮﻩﻫﺎ
ﺍﻟﺒﺘﻪ ﺩﻣﭙﺮﻫﺎ ﺍﮔﺮ ﮐﺎﻣﻼ ﺑﺎﺯ ﺑﺎﺷﻨﺪ ،ﻣﻘﺎﻭﻣﺖ
ﮐﺎﻧﺎﻝ ،ﻣﯽﺗﻮﺍﻧﺪ ﺑﺪﻭﻥ ﻣﺘﻮﻗﻒ ﮐﺮﺩﻥ ﻣﻮﺗﻮﺭ
ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 37ﺷﻤﺎﺭﻩ 30
ﺳﺮﻋﺖ ﺁﻥ ﺭﺍ ﺑﻪ ﻃﻮﺭ ﺧﻮﺩﮐﺎﺭ ﺗﻐﯿﯿﺮ ﺩﻫﺪ.
ﺍﺯ ﻣﻨﺒﻊ ﺑﻪ ﺳﺎﺧﺘﻤﺎﻥ ﺍﺳﺖ .ﺍﯾﻦ ﻭﺍﭘﯿﭽﺶ
ﺍﯾﻦ ﻣﺴــﺎﻟﻪ ﺑﻪﺧﺼﻮﺹ ﺩﺭ ﺳﯿﺴــﺘﻢﻫﺎﯼ
ﻣﯽﺗﻮﺍﻧﺪ ﺑﺮ ﻋﻤﻠﮑﺮﺩ ﺳﺎﯾﺮ ﻭﺳﺎﯾﻞ ﺍﻟﮑﺘﺮﯾﮑﯽ
ﺍﻏﻠــﺐ ﮐﺎﻧــﺎﻝ ﺑــﺮﺍﯼ ﺻﺪﺍﮔﯿــﺮﯼ ﻭ
ﺣﺠﻢ ﻣﺘﻐﯿﺮ VFDﻣﻬﻢ ﺍﺳــﺖ؛ ﺯﯾﺮﺍ ﺑﺮﺍﯼ
)ﻣﺎﻧﻨــﺪ ﮐﺎﻣﭙﯿﻮﺗﺮﻫﺎ( ﺩﺭ ﺳــﺎﺧﺘﻤﺎﻥ ﺗﺎﺛﯿﺮ
ﻋﺎﯾــﻖﮐﺎﺭﯼ ﺗﻮﺳــﻂ ﻏﻼﻑ ﭘﻮﺷــﺶ ﺩﺍﺩﻩ
ﺗﻄﺒﯿﻖ ﺑﺎ ﺗﻐﯿﯿﺮﺍﺕ ﻓﺸــﺎﺭ ﺍﺳــﺘﺎﺗﯿﮏ ﺩﺭ
ﺑﮕــﺬﺍﺭﺩ .ﺍﮔــﺮ ﻧﺼــﺐ VFDﺑــﺮ ﻋﻤﻠﮑﺮﺩ
ﻣﯽﺷﻮﺩ .ﻏﻼﻑ ﺗﻮﺳﻂ ﭼﺴﺐ ﻭ ﺑﺴﺖﻫﺎﯼ
ﮐﺎﻧﺎﻝ ،ﺳــﺮﻋﺖ ﻓﻦ ﺑﺎﯾﺪ ﺑﻪ ﻃﻮﺭ ﻣﺘﻨﺎﻭﺏ
ﺩﯾﮕﺮ ﻭﺳــﺎﯾﻞ ﺍﻟﮑﺘﺮﯾﮑﯽ ﺗﺎﺛﯿــﺮ ﺑﮕﺬﺍﺭﺩ ،ﺍﺯ
ﻣﺨﺼﻮﺹ ﺑﻪ ﮐﺎﻧﺎﻝ ﻣﺘﺼﻞ ﻣﯽﺷﻮﺩ.
ﺗﻐﯿﯿﺮ ﮐﻨﺪ.
ﯾﮏ ﻭﺳــﯿﻠﻪ ﻓﯿﻠﺘﺮﮐﻨﻨﺪﻩ ﻫﺎﺭﻣﻮﻧﯿﮏ ﺑﺮﺍﯼ
ﻣﺰﯾﺖ ﺩﯾﮕﺮ VFDﺍﯾﻦ ﺍﺳﺖ ﮐﻪ ﮐﺎﻫﺶ
ﺑﺮﻃﺮﻑ ﮐﺮﺩﻥ ﻣﺸﮑﻞ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ.
ﺑﺮﺍﯼ ﺟﺬﺏ ﺻﺪﺍ ﻃﺮﺍﺣﯽ ﻣﯽﺷﻮﺩ.
ﻣﻌﻤــﻮﻻ ﻏﻼﻑ ﮐﺎﻧــﺎﻝ ﺍﺯ ﺧﺮﻭﺟﯽ ﻓﻦ ﺁﻏﺎﺯ ﻧﻤﯽﺷــﻮﺩ ،ﺑﻠﮑﻪ ﺑﻌﺪ ﺍﺯ ﺍﻭﻟﯿﻦ ﺍﻓﺰﺍﯾﺶ
ﺳــﺮﻋﺖ ﻣﻮﺗــﻮﺭ ،ﺍﻧــﺮﮊﯼ ﻻﺯﻡ ﺭﺍ ﮐﺎﻫﺶ
VFDﻫــﺎﯼ ﺍﻭﻟﯿــﻪ ﺩﺭ ﺍﺭﺗﻔﺎﻉﻫﺎﯼ ﺯﯾﺎﺩ
ﺩﺭ ﺍﻧﺪﺍﺯﻩ ﮐﺎﻧﺎﻝ ﺷــﺮﻭﻉ ﻣﯽﺷــﻮﺩ .ﺩﺭ ﺍﯾﻦ
ﻣﯽﺩﻫﺪ .ﺍﯾــﻦ ﮐﺎﺭ ﻣﻮﺟــﺐ ﺻﺮﻓﻪﺟﻮﯾﯽ
ﺍﺯ ﺳــﻄﺢ ﺩﺭﯾﺎ ﺩﺍﻍ ﻣﯽﮐﺮﺩﻧﺪ .ﺍﯾﻦ ﻣﺸﮑﻞ
ﻗﺴﻤﺖ ،ﺳﺮﻋﺖ ﻫﻮﺍ ﮐﺎﻫﺶ ﯾﺎﻓﺘﻪ ﻭ ﺍﺣﺘﻤﺎﻝ
ﺯﯾــﺎﺩﯼ ﺩﺭ ﻫﺰﯾﻨﻪ ﺍﻧﺮﮊﯼ ﻣﯽﺷــﻮﺩ .ﻣﺜﻼ
ﺑﺮﻃﺮﻑ ﺷــﺪﻩ ﻭ ﺍﮐﻨﻮﻥ VFDﻭﺳﯿﻠﻪﺍﯼ ﺑﺎ
ﺟﺪﺍ ﺷﺪﻥ ﺍﺗﺼﺎﻻﺕ ﻏﻼﻑ ﮐﻤﺘﺮ ﺍﺳﺖ .ﺩﺭ
ﺩﺭﯾــﮏ ﺳﯿﺴــﺘﻢ VAVﮐﺎﻫﺶ 25%ﺩﺭ
ﻗﺎﺑﻠﯿﺖ ﺍﻃﻤﯿﻨﺎﻥ ﺑﺎﻻ ﺍﺳﺖ .ﺑﺮﺣﺴﺐ ﺍﻧﺪﺍﺯﻩ
ﺳﯿﺴﺘﻤﯽ ﮐﻪ ﺑﺮﺍﯼ ﻣﺪﺗﯽ ﮐﺎﺭ ﮐﺮﺩﻩ ﺍﺳﺖ،
ﺳــﺮﻋﺖ ﻣﻮﺗﻮﺭ ﻓﻦ ﻣﻨﺠﺮ ﺑﻪ ﮐﺎﻫﺶ 50%
ﻭ ﻧﻮﻉ VFDﻣﻤﮑﻦ ﺍﺳﺖ ﺩﺍﺭﺍﯼ ﻭﯾﮋﮔﯽﻫﺎﯼ
ﻗﺴﻤﺖﻫﺎﯼ ﺟﺪﺍﺷﺪﻩ ﻣﻤﮑﻦ ﺍﺳﺖ ﻣﻨﺠﺮ ﺑﻪ
ﺩﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﻣﯽﺷﻮﺩ VFD .ﺑﻪ ﻃﻮﺭ
ﺯﯾﺮ ﺑﺎﺷﺪ.
ﺁﻟﻮﺩﮔﯽ ﭘﺮﻩﻫﺎ ﻭ ﺩﺍﻍﮐﺮﺩﻥ ﺳﯿﻢﭘﯿﭻﻫﺎ ﺷﺪﻩ
ﺳــﺮﻋﺖ ﻣﻮﺗﻮﺭ ﺑﻪﺗﺪﺭﯾﺞ ﺯﯾﺎﺩ ﻣﯽﺷﻮﺩ ﺗﺎ ﺑﻪ
ﺑﻌﻀﯽ ﻭﻗﺖﻫﺎ ﺑﺮﺍﯼ ﮐﻢﮐﺮﺩﻥ ﻓﺮﺳــﺎﯾﺶ ﺍﺯ
ﻣﻘﺪﺍﺭ ﻣﻄﻠﻮﺏ ﺑﺮﺳﺪ.
ﻏﻼﻑﻫﺎﯼ ﻧﺌﻮﭘﺮﯾﻦ ﺩﺭ ﺻﺪﺍﮔﯿﺮ ﺍﺳــﺘﻔﺎﺩﻩ
ﺧﻮﺩﮐﺎﺭ ﻣﺼﺮﻑ ﺍﻧﺮﮊﯼ ﺭﺍ ﺑﻬﯿﻨﻪ ﻣﯽﺳــﺎﺯﺩ ﮐﻪ ﺑﺮﺍﯼ ﻣﺼﺮﻑﮐﻨﻨﺪﻩ ﺳﻮﺩﺁﻭﺭ ﺍﺳﺖ. VFDﻓﻘــﻂ ﺑﺎﯾﺪ ﺗﻮﺳــﻂ ﺗﮑﻨﯿﺴــﯿﻦ ﺍﻟﮑﺘﺮﻭﻧﯿﮏ ﺁﻣﻮﺯﺵﺩﯾﺪﻩ ﺳــﺮﻭﯾﺲ ﻭ ﻧﺼﺐ
ﻭﻟﺘﺎﮊ ﻭ ﺟﺮﯾﺎﻥ ﻣﻮﺗﻮﺭ ﺭﺍ ﻧﺸﺎﻥ ﻣﯽﺩﻫﺪ.
ﺷﻮﺩ.
ﺑﻌﻀــﯽ ﺍﺯ ﻓﻦﻫﺎ ،ﺧﻮﺩﺷــﺎﻥ ﺻﺪﺍﮔﯿﺮ
ﺍﮔﺮ ﻣﺸﺨﺺ ﺷــﻮﺩ ﮐﻪ ﻓﻦ ﺑﺎ ﺳﺮﻋﺖ
ﻭﺳﯿﻠﻪﺍﯼ ﮐﻪ ﺗﻮﺳﻂ ﺁﻥ ﺑﺘﻮﺍﻥ ﻣﻮﻗﺘﺎ
ﺩﺍﺭﻧﺪ .ﺍﯾﻦ ﻭﺳﯿﻠﻪﺍﯼ ﺩﺭ ﮐﺎﻧﺎﻝ ﺍﺳﺖ ﮐﻪ ﺻﺪﺍ
ﻣﻨﺎﺳــﺐ ﮐﺎﺭ ﻧﻤﯽﮐﻨﺪ ،ﺑﺎﯾﺪ ﺑﻪ ﺗﮑﻨﯿﺴﯿﻦ
ﻓﺮﮐﺎﻧﺲ ﻣﻮﺗﻮﺭ ﺭﺍ ﺗﻐﯿﯿﺮ ﺩﺍﺩ .ﺍﯾﻦ ﮐﺎﺭ ﻫﻨﮕﺎﻡ
ﺭﺍ ﺧﻔﻪ ﻣﯽﮐﻨﺪ .ﺍﯾﻦ ﻭﺳﯿﻠﻪ ﻣﯽﺗﻮﺍﻧﺪ ﺑﺴﯿﺎﺭ
ﺍﻟﮑﺘﺮﻭﻧﯿــﮏ ﻣﺮﺍﺟﻌﻪ ﮐﺮﺩ .ﺑــﺎ ﺍﯾﻦ ﻭﺟﻮﺩ
ﺁﺯﻣﺎﯾــﺶ ،ﺗﻨﻈﯿﻢ ﻭ ﻣﺘﻌﺎﺩﻝﺳــﺎﺯﯼ ﻣﻔﯿﺪ
ﻣﺤﺪﻭﺩﮐﻨﻨﺪﻩ ﺑﺎﺷــﺪ ﻭ ﺑﺮ ﮐﺎﺭﺍﯾﯽ ﺳﯿﺴﺘﻢ
ﺍﺣﺘﻤﺎﻻ ﺗﮑﻨﯿﺴــﯿﻦﻫﺎ ﻧﺤﻮﻩ ﺗﻨﻈﯿﻢ VFD
ﺍﺳﺖ.
ﺍﺛﺮ ﺑﮕــﺬﺍﺭﺩ .ﺍﮔﺮ ﯾﮏ ﻓﻦ ﺑﻪ ﻫﻤﺮﺍﻩ ﺻﺪﺍﮔﯿﺮ
ﺭﺍ ﺑﻠﺪ ﻫﺴﺘﻨﺪ؛ ﺍﻣﺎ ﺩﺭ ﻣﻮﺭﺩ ﺳﯿﺴﺘﻢ ﮐﺎﻧﺎﻝ ﻭ ﻣﻠﺰﻭﻣــﺎﺕ ﺁﻥ ﺍﻃﻼﻋﺎﺗﯽ ﻧﺪﺍﺭﻧﺪ .ﻭﻇﯿﻔﻪ ﺷــﻤﺎ ﺑﺮﺭﺳــﯽ ﺍﯾﻦ ﻣﻄﺎﻟﺐ ﺍﺳــﺖ ﮐﻪ ﺁﯾﺎ VFDﻧﯿﺎﺯﻫﺎﯼ ﺳﯿﺴــﺘﻢ ﺭﺍ ﺑﺮﺁﻭﺭﺩﻩ ﮐﻨﺪ ﻭ ﻧﮑﻨﺪ.
ﺑﺮﺧﯽ ﺑﺮﺝﻫﺎﯼ ﺧﻨﮏﮐﻦ ﻣﻔﯿﺪ ﺍﺳﺖ. ﻗﺎﺑﻠﯿﺖ ﭘﺮﺩﺍﺯﺵ ﺳــﯿﮕﻨﺎﻝ ﻭﺭﻭﺩﯼ
ﻭ ﺧﺮﻭﺟﯽ ﺭﺍ ﺑﺮﺭﺳــﯽ ﮐﻨﯿﺪ ﺗﺎ ﻣﻌﻠﻮﻡ ﺷﻮﺩ ﻣﺸﮑﻞ ﺍﺯ ﺻﺪﺍﮔﯿﺮ ﺍﺳﺖ ﯾﺎ ﺧﯿﺮ.
ﻧﯿﻮﻣﺎﺗﯿﮏ ﯾﺎ ﺍﻟﮑﺘﺮﻭﻧﯿﮏ ﺩﺭ ) CPUﭘﺮﺩﺍﺯﻧﺪﻩ ﻣﺮﮐﺰﯼ(
VFDﺑﯿــﻦ ﻣﻮﺗﻮﺭ ﻭ ﮐﻠﯿﺪ ﻗﻄﻊ ﺍﺗﺼﺎﻝ
ﻣﻨﻈﻮﺭ ﺍﺯ ﺻﺪﺍﮔﯿﺮ ﺑﺮﺍﯼ ﻓﻦ ،ﻭﺳﯿﻠﻪﺍﯼ
ﻣﻮﺗﻮﺭ ﺟﺎﯼ ﻣﯽﮔﯿﺮﺩ .ﺍﮔﺮ ﻗﺮﺍﺭ ﺍﺳﺖ ﻣﻮﺗﻮﺭ
ﺍﺳــﺖ ﮐﻪ ﺑﺮﺍﯼ ﮐﺎﻫﺶ ﺻــﺪﺍﯼ ﺗﻮﻟﯿﺪﯼ
ﻓــﻦ ﺭﺍ ﻣﺘﻮﻗﻒ ﮐﻨﯿﺪ ،ﻗﺒــﻞ ﺍﺯ ﺯﺩﻥ ﮐﻠﯿﺪ
ﺗﻮﺳــﻂ ﻓﻦ ﻃﺮﺍﺣﯽ ﻣﯽﺷــﻮﺩ .ﺗﻤﺎﻡ ﺻﺪﺍ
ﻗﻄﻊ ،ﺍﺑﺘــﺪﺍ VFDﺭﺍ ﺧﺎﻣﻮﺵ ﮐﻨﯿﺪ .ﺍﮔﺮ
ﺭﺍ ﻧﻤﯽﺗﻮﺍﻥ ﺣﺬﻑ ﮐﺮﺩ )ﻣﺨﺼﻮﺻﺎ ﺻﺪﺍﯼ
ﻫﻨــﮕﺎﻡ ﺯﺩﻥ ﮐﻠﯿﺪ ﻗﻄﻊ ﺍﺗﺼﺎﻝ VFD ،ﺩﺭ
ﻫﻮﺍ ﺭﺍ( .ﺩﺭ ﺧﯿﻠﯽ ﺍﺯ ﮐﺎﺭﺑﺮﺩﻫﺎ ،ﺑﻪ ﺻﺪﺍﮔﯿﺮ
ﺣﺎﻝ ﮐﺎﺭ ﺑﺎﺷﺪ VFD ،ﻣﻤﮑﻦ ﺍﺳﺖ ﺻﺪﻣﻪ
ﺩﺭ ﮐﺎﻧﺎﻝ ﻧﯿﺎﺯ ﺍﺳﺖ .ﻏﻼﻑ ﮐﺎﻧﺎﻝ ،ﻣﺎﺩﻩﺍﯼ
ﺑﺒﯿﻨﺪ.
ﻣﺨﺼﻮﺹ ﺍﺳﺖ ﮐﻪ ﺑﻪ ﺩﺍﺧﻞ ﮐﺎﻧﺎﻝ ﺑﺴﺘﻪ
VFDﻣﯽﺗﻮﺍﻧــﺪ ﻣﻮﺟــﺐ ﺍﻋﻮﺟــﺎﺝ
ﻣﯽﺷــﻮﺩ .ﺿﺨﺎﻣﺖ ﺁﻥ ﺑﯿﻦ /4ﺗﺎ 1ﺍﯾﻨﭻ
ﻫﺎﺭﻣﻮﻧﯿــﮏ ﺩﺭ ﻣﻨﺒﻊ ﺗﻐﺬﯾﻪ ﺷــﻮﺩ .ﺍﯾﻦ
ﺍﺳــﺖ ﻭ ﺑﺮﺍﯼ ﻣﻘﺎﻭﻣﺖ ﺩﺭ ﻣﻘﺎﺑﻞ ﭘﺎﺭﮔﯽ ﺑﺮ
ﭘﺪﯾﺪﻩ ،ﺗﻐﯿﯿﺮ ﺩﺭ ﺟﺮﯾﺎﻥ ﻣﺘﻨﺎﻭﺏ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ
ﺍﺛﺮ ﺟﺮﯾﺎﻥ ﻫﻮﺍ ﺗﻮﺍﻥ ﻻﺯﻡ ﺭﺍ ﺩﺍﺭﺩ .ﺍﯾﻦ ﻣﺎﺩﻩ
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺗﻠﻔﻦ55401278 :
ﺻﺪﺍﮔﯿﺮﯼ
3
ﺗﺼﻮﻳﺮ ) (10ﻣﺤﺮﻙ ﻓﺮﻛﺎﻧﺲ ﻣﺘﻐﻴﺮ )(VFD
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﻓﻦ ﺧﺎﺭﺝ ﺍﺯ ﻣﺤﺪﻭﺩﻩ ﻣﺸﺨﺺ ﺧﻮﺩ ،ﮐﺎﺭ
ﻣﻌﮑﻮﺱﮐﻨﻨﺪﻩ ﻣﻮﺗﻮﺭ ،ﺍﯾﻦ ﻭﺳﯿﻠﻪ ﺩﺭ
ﮐﺎﺭﺍﯾﯽ ﺿﻌﯿﻔﯽ ﺩﺍﺷﺖ ،ﻣﻘﺎﻭﻣﺖ ﺩﺭ ﻭﺭﻭﺩﯼ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
ﻧﺸﺎﻧﮕﺮ ﺩﯾﺠﯿﺘﺎﻝ ﮐﻪ ﻓﺮﮐﺎﻧﺲ )ﻫﺮﺗﺰ(،
ﻣﯽﺷﻮﺩ.
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺷــﺮﻭﻉﺑﻪﮐﺎﺭ ﺁﺭﺍﻡ ،ﺑﻪ ﺍﯾﻦ ﻣﻌﻨﯽ ﮐﻪ
ﻭ ﺑﻪﺷــﺪﺕ ﺑﺮ ﮐﺎﺭﺍﯾﯽ ﺳﯿﺴﺘﻢ ﺍﺛﺮ ﺑﮕﺬﺍﺭﻧﺪ.
ﺻﻔﺤﻪ / 38ﺷﻤﺎﺭﻩ 30
ﺗﺠﺎﺭﻯ
ﺍﻧﺘﺨﺎﺏ ﻣﺒﺮﺩ ﭼﻴﻠﺮﻫﺎ ﭘﻨﺞ ﺩﻟﯿﻠﯽ ﮐﻪ ﺑﻪ ﻋﻠﺖ ﺁﻥﻫﺎ HFC - 134 aﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ﻣﻨﺘﺨﺐ ﺑﺮﺍﯼ ﭼﯿﻠﺮﻫﺎ ﺍﺳﺖ ﺑﻪ ﺷﺮﺡ ﺯﯾﺮ ﻫﺴﺘﻨﺪ.
-1ﻫﺰﯾﻨﻪﻫﺎﯼ ﻋﻤﻠﯿﺎﺗﯽ ﻭ ﺍﻭﻟﯿﻪ ● ﺍﺭﻭﭘــﺎ ﻭﺍﺭﺩﺍﺕ ﭼﯿﻠﺮﻫــﺎﯼ HCFCﺑﺰﺭﮒﺗــﺮ ﺍﺯ 200ﺗــﻦ ﺭﺍ ﺩﺭ ﺳــﺎﻝ 2000ﻣﺘﻮﻗــﻒ ﮐﺮﺩﻩ ﮐﻪ ﺍﯾﻦ ﺍﺗﻔﺎﻕ ﺩﺭ ﺳــﺎﻝ 2020
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺩﺭ ﮐﺸــﻮﺭﻫﺎﯼ ﺩﺭﺣﺎﻝ ﺗﻮﺳــﻌﻪ ﻧﯿــﺰ ﺭﻭﯼ ﻣﯽﺩﻫﺪ .ﺑــﺎ ﺍﻧﺘﺨﺎﺏ ،HFC - 134 aﺍﺯ ﺗﺠﻬﯿــﺰﺍﺕ HCFCﮐــﻪ ﻣﯽﺗﻮﺍﻧﻨﺪ ﺳــﺮﯾﻊﺗﺮ ﺍﺯ ﺭﺩﻩ ﺧﺎﺭﺝ ﺷــﻮﻧﺪ ،ﺍﺟﺘﻨﺎﺏ ﻣﯽﺷــﻮﺩ .ﺍﯾﻦ ﺍﻣــﺮ ﻣﺎﻧﻊ ﺍﺯ ﻫﺰﯾﻨﻪ ﺟﺎﺑﻪﺟﺎﯾﯽ ﭘﯿﺶ ﺍﺯ ﭘﺎﯾﺎﻥ ﻋﻤﺮ ﮐﺎﻣﻞ ﺗﺠﻬﯿﺰﺍﺕ ﺧﻮﺍﻫﺪ ﺷﺪ.
ﺗﺼﻮﯾﺮ ) (2ﻣﻘﺎﯾﺴﻪ ﻫﺰﯾﻨﻪﻫﺎﯼ ﻧﺼﺐ ﭼﯿﻠﺮﻫﺎﯼ ﻓﺸﺎﺭ ﻣﺜﺒﺖ ﻭ ﻣﻨﻔﯽ
-2ﮐﺎﺭﺍﯾﯽ ﺑﺮﺧﻼﻑ ﭼﯿﻠﺮﻫﺎﯾﯽ ﺑﺎ ﻓﺸﺎﺭ ﻣﻨﻔﯽ ﮐﻪ ﺑﺎ ﮔﺬﺷﺖ ﺯﻣﺎﻥ ،ﮐﺎﺭﺍﯾﯽ ﺧﻮﺩ ﺭﺍ ﺍﺯ ﺩﺳــﺖ ﻣﯽﺩﻫﻨﺪ ،ﮐﺎﺭﺍﯾــﯽ ﭼﯿﻠﺮ HFC - 134 aﻣﺎﻧﻨﺪ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﺭﻭﺯ ﺍﻭﻝ ﺑﺎﻗﯽ ﻣﯽﻣﺎﻧﺪ.
ﺗﺼﻮﯾﺮ ) (1ﻭﺿﻌﯿﺖ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸﯽ HCFCﺩﺭ ﺟﻬﺎﻥ ﻭ ﻣﺮﺍﺣﻞ ﺍﺯ ﺭﺩﻩ ﺧﺎﺭﺝ ﺷﺪﻥ ﺩﺭ ﺍﺭﻭﭘﺎ ﻭ ﺩﯾﮕﺮ ﮐﺸﻮﺭﻫﺎ ● ﺗﻮﻟﯿﺪﮐﻨﻨﺪﮔﺎﻥ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸــﯽ ﻭ ﺗﺠﻬﯿﺰﺍﺕ ﺑﻪ ﺳــﻤﺖ HFCﺣﺮﮐــﺖ ﮐﺮﺩﻩ ﻭ ﺩﺭﺣﻘﯿﻘﺖ ﻣﻤﮑﻦ ﺍﺳــﺖ ﭘﯿﺶ ﺍﺯ ﻫﺮ ﺍﻟﺰﺍﻡ ﻗﺎﻧﻮﻧﯽ HCFCﻫﺎ ﺭﺍ ﺍﺯ ﺭﺩﻩ ﺧﺎﺭﺝ ﮐﻨﻨﺪ. ● ﭼﯿﻠــﺮﯼ ﺑﺎ ﻓﺸــﺎﺭ ﻣﺜﺒﺖ ،ﭼﯿﻠــﺮﯼ ﮐﺎﻣﻞ ﻫﻤــﺮﺍﻩ ﺑﺎ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸــﯽ ﺍﺳﺖ ﮐﻪ ﺣﺎﻭﯼ ﺁﻥ ﺍﺳﺖ .ﺍﯾﻦ ﭼﯿﻠﺮ ﻧﯿﺎﺯﯼ ﺑﻪ 24700 ﺩﻻﺭ ﺍﺿﺎﻓﯽ ﺑﺮﺍﯼ ﺗﺠﻬﯿﺰﺍﺕ ﺟﺎﻧﺒﯽ ﻭ ﻫﺰﯾﻨﻪﻫﺎﯼ ﻧﮕﻬﺪﺍﺭﯼ ﻧﺪﺍﺭﺩ. ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﺗﺼﻮﯾﺮ ) (3ﺍﺗﻼﻑ ﮐﺎﺭﺍﯾﯽ ﻓﺸﺎﺭ ﻣﺜﺒﺖ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
ﺻﻔﺤﻪ / 39ﺷﻤﺎﺭﻩ 30
ﻣﯽﺷﻮﺩ ﻭ ﻧﻪﺗﻨﻬﺎ ﺑﻪ ﻋﻨﻮﺍﻥ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺳﺎﺯﻧﺪﻩ ،ﺑﻪ ﻋﻨﻮﺍﻥ ﭼﯿﻠﺮﯼ
-3ﺍﯾﻤﻨﯽ ﻭ ﺿﻤﺎﻧﺖ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ
ﺗﻀﻤﯿﻦﺷﺪﻩ ﺑﻪ ﻭﺳﯿﻠﻪ ﯾﮏ ﮐﻤﭙﺎﻧﯽ ﻣﺴﺘﻘﻞ ﺑﯿﻤﻪﮐﻨﻨﺪﻩ ﺑﺎﺯﺭﺳﯽ ﻣﯽﺷﻮﺩ. ● ﺑــﺎ ﮔﺬﺷــﺖ ﺯﻣــﺎﻥ ﻭ 1%ﻧﺸــﺘﯽ ،ﺧﻮﺭﺩﮔــﯽ ﺑــﺎ HFC - 134 aﺑﻪ ﺍﻧﺪﺍﺯﻩ ﭼﯿﻠﺮﯼ ﺑﺎ ﻓﺸــﺎﺭ ﻣﻨﻔﯽ ﻧﺨﻮﺍﻫﺪ ﺑﻮﺩ. ﺑﻪ ﺩﻟﯿﻞ ﮐﺎﺭ ﺩﺭ ﻓﺸــﺎﺭﯼ ﺑﺎﻻﺗﺮ ﺍﺯ ﻓﺸﺎﺭ ﺍﺗﻤﺴﻔﺮ ،ﺧﻮﺭﺩﮔﯽ ﺑﺎﻋﺚ ● HFC - 134 aﺍﯾﻤﻦﺗﺮﯾﻦ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸــﯽ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ
ﺍﻧﺘﺸﺎﺭ ﻫﻮﺍ ﯾﺎ ﺁﺏ ﺑﻪ ﺩﺍﺧﻞ ﻧﻤﯽﺷﻮﺩ.
ﺍﺳــﺖ .ﺑﻪ ﺩﻟﯿــﻞ ﺁﻥﮐﻪ ﺍﯾﻦ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸــﯽ ﺩﺭ ﺑــﺪﻥ ﻣﺘﺎﺑﻮﻟﯿﺰ
● ﮐﯿﻔﯿﺖ ﻭ ﭘﺎﯾﺪﺍﺭﯼ ﻓﺸﺎﺭ ﻣﺜﺒﺖ
ﻧﻤﯽﺷﻮﺩ ،ﻣﯽﺗﻮﺍﻧﺪ ﺑﺮﺍﯼ ﺗﻨﻔﺲ ﮐﻨﺘﺮﻝﺷﺪﻩ ﺍﺳﺘﻔﺎﺩﻩ ﺷﻮﺩ )ﺍﻓﺮﺍﺩﯼ
-5ﺍﻧﺪﺍﺯﻩ ﻣﺤﺼﻮﻝ
ﺑﺎ ﻣﺸﮑﻼﺕ ﺗﻨﻔﺴﯽ ﮐﻪ ﺍﺯ ﺍﯾﻦ ﻣﺤﺮﮎﻫﺎ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﮐﻨﻨﺪ(. ● ﺗﻤــﺎﻡ ﻣﺎﯾﻌــﺎﺕ ﺳﺮﻣﺎﯾﺸــﯽ ﺑﺎﯾﺪ ﻣﻨﻄﺒﻖ ﺑﺮ ﻣــﻮﺍﺭﺩ ﺍﯾﻤﻨﯽ ASHRAE 15ﺑﺎﺷﻨﺪ .ﭼﺮﺍ ﺑﺎﯾﺪ ﻫﻨﮕﺎﻡ ﺍﻧﺠﺎﻡ ﺟﻮﺵ ﺳﺮﺩ ،ﺧﻄﺮ ﺭﺍ ﺍﻓﺰﺍﯾﺶ ﺩﺍﺩ؟
-4ﮐﯿﻔﯿﺖ ﻭ ﭘﺎﯾﺪﺍﺭﯼ
ﺳﺎﺧﺘﻤﺎﻧﯽ ﺟﺎﯼ ﻣﯽﮔﯿﺮﺩ .ﻃﺮﺣﯽ ﺑﺎ ﺍﺟﺰﺍﯼ ﮐﻮﭼﮏ ﻭ ﻗﺮﺍﺭﮔﺮﻓﺘﻦ ● ﺑﺮﺧﻼﻑ ﭼﯿﻠﺮﻫﺎﯾﯽ ﺑﺎ ﻓﺸﺎﺭ ﻣﻨﻔﯽ ﮐﻪ ﻧﺸﺖ ﺁﻥﻫﺎ ﺑﻪ 15% ﺩﺭ ﺳــﺎﻝ ﻣﯽﺭﺳــﺪ HFC - 134 a ،ﺑﺎ ﻓﺸــﺎﺭ ﻣﺜﺒﺖ ﻣﻨﻄﺒﻖ ﺑﺎ ﻣﻮﺍﺭﺩ ﻓﺸﺎﺭ ASMEﺑﺨﺶ ﻫﺸﺖ ،ﺳﺎﺧﺘﻪ ﻣﯽﺷﻮﺩ .ﺑﻪ ﺻﻮﺭﺕ
ﺩﺭ ﻣﺤﻞ ﺑﻪ ﺍﯾﻦ ﻣﻌﻨﯽ ﺍﺳﺖ ﮐﻪ ﻭﺍﺣﺪ ﭼﯿﻠﺮ ﮐﺎﻣﻼ ﻣﻨﺎﺳﺐ ﮐﺎﺭﺑﺮﺩ ﺷﻤﺎ ﺍﺳﺖ. HFC - 134 aﻧﻪﻓﻘﻂ ﯾﮏ ﻣﺎﯾﻊ ﺳﺮﻣﺎﯾﺸﯽ ،ﻋﺎﻣﻠﯽ ﮐﻠﯿﺪﯼ ﺩﺭ ﻃﺮﺍﺣﯽ ﭼﯿﻠﺮﻫﺎﯾﯽ ﺑﺎﺩﻭﺍﻡ ﺍﺳﺖ.
ﻓﻦﮐﻮﯾﻞﻫﺎﯼ ﻃﺮﺡ ﺻﺒﺎ ﺳﺎﺧﺘﻪﺷـﺪﻩ ﺍﺯ ﻣﺮﻏﻮﺏﺗﺮﯾﻦ ﻣﻮﺍﺩ ﺍﻭﻟﯿﻪ ﻭ ﭘﯿﺸـﺮﻓﺘﻪﺗﺮﯾﻦ ﻣﺘﺪﻫﺎﯼ ﺳـﺎﺧﺖ ﻭ ﺗﺠﻬﯿﺰﺍﺕ ﺑﺴﯿﺎﺭ ﭘﯿﺸﺮﻓﺘﻪ ،ﺩﺭ ﺍﻏﻠﺐ ﮐﺎﺭﺑﺮﯼﻫﺎﯼ ﻣﺴﮑﻮﻧﯽ ،ﺗﺠﺎﺭﯼ ﻭ ﺍﺩﺍﺭﯼ ،ﻧﯿﺎﺯ ﺑﻬﺮﻩﺑﺮﺩﺍﺭﺍﻥ ﺍﯾﻦ ﺗﺠﻬﯿﺰﺍﺕ ﺭﺍ ﺑﺮﻃﺮﻑ ﻣﯽﻧﻤﺎﯾﺪ.
ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﺷﺮﻛﺖ Roburﺍﻳﺘﺎﻟﻴﺎ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺗﻠﻔﻦ88739880-2:
ﻫﻮﺍﺳﺎﺯﻫﺎﻯ ﺟﺪﻳﺪ ﺳﺮﻯ 39FDﻛﺮﻳﺮ ﺗﻠﻔﻦ88739880-2:
ﺗﻠﻔﻦ55401278 :
ﺳﺎﺯﻧﺪﻩ ﻣﺮﻏﻮﺏﺗﺮﯾﻦ ﻓﻦﮐﻮﯾﻞ ﺳﺎﺧﺖ ﺍﯾﺮﺍﻥ
ﺟﻬﺖ ﺗﻬﻴﻪ ﻣﺠﻼﺕ ﻭ ﻛﺘﺎﺏﻫﺎﻯ ﺗﺎﺳﻴﺴﺎﺗﻰ ﻭ ﺍﻃﻼﻉ ﺍﺯ ﺩﻭﺭﻩﻫﺎﻯ ﺁﻣﻮﺯﺷﻰ ﺧﺎﻧﻪ ﺗﺎﺳﻴﺴﺎﺕ ﺑﺎ ﻣﺎ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﺗﻠﻔﻦ22885647-50:
ﮔﺮﻭﻩ ﻣﻬﻨﺪﺳﻴﻦ ﻣﺸﺎﻭﺭ ﺍﺭﻭﻧﺪ ﺳﺮﻭﻳﺲ
ﮐﺎﻣﻼ ﻣﺠﺰﺍ ﻫﺮ ﺍﺗﺼﺎﻝ ﻭ ﭘﯿﭻ ﺑﻪ ﻭﺳــﯿﻠﻪ ﺑﺨﺶ ﺑﺎﺯﺭﺳــﯽ ﺑﺮﺭﺳﯽ
ﺍﺭﻭﻧﺪ ﺑﺎ ﺩﻓﺘﺮ ﻧﺸﺮﻳﻪ ﺗﻤﺎﺱ ﺑﮕﻴﺮﻳﺪ
ﮐﻪ ﻣﯽﺗﻮﺍﻥ ﻭﺍﺣﺪ ﭼﯿﻠﺮ ﻓﺸــﺮﺩﻩﺍﯼ ﺳــﺎﺧﺖ ﮐﻪ ﺑﻪﺁﺳﺎﻧﯽ ﺩﺭ ﻫﺮ
ﺟﻬﺖ ﺳﻔﺎﺭﺵ ﺁﮔﻬﻰ ﺩﺭ ﻧﺸﺮﻳﻪ
● ﺟﺮﻡ ﻣﻮﻟﮑﻮﻟﯽ ﺍﻧﺪﮎ HFC - 134 aﺑﻪ ﺍﯾﻦ ﻣﻌﻨﯽ ﺍﺳــﺖ
ﺻﻔﺤﻪ / 40ﺷﻤﺎﺭﻩ 30
ﻧﻜﺘﻪ
ﻧﮕﺎﻫﻰ ﺑﻪ HCFC - 22
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﺷﻌﻠﻪ ﻣﺴﺘﻘﻴﻢ
ﺩﺭ 12ﺩﺳــﺎﻣﺒﺮ ،1995ﭘﺮﻭﺗــﮑﻞ ﻣﻮﻧﺘــﺮﺍﻝ ﺍﺻﻼﺡ ﺷــﺪ ﺗﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸﯽ HCFCﺭﺍ ﺩﺭ ﺑﺎﺯﺍﺭ ﺟﻬﺎﻧﯽ ﻣﺤﺪﻭﺩ
● ﺩﺭ ﻭﺍﮐﻨــﺶ ﺑــﻪ ﻗﻮﺍﻧﯿﻨــﯽ ﻣﺎﻧﻨــﺪ ﻗﺎﻧــﻮﻥ ﻫــﻮﺍﯼ ﭘﺎﮎ،
ﮐﻨــﺪ .ﺩﺭ 1992ﭘﻮﺷﺸــﯽ ﺑﺮﺍﯼ 3.1%ﺭﺷــﺪ ﺗﻮﻟﯿﺪ HCFCﺩﺭ
HCFC - 22ﺑﻪ ﺻﻮﺭﺗﯽ ﺍﺳﺘﻔﺎﺩﻩ ﻣﯽﺷﻮﺩ ﮐﻪ ﺩﺭ ﺑﺮﺧﯽ ﻣﻮﺍﺭﺩ،
ﮐﺸــﻮﺭﻫﺎﯼ ﺩﺭﺣﺎﻝ ﺗﻮﺳــﻌﻪ ﺩﺭﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷــﺪ .ﻋﻼﻭﻩ ﺑﺮ ﺍﯾﻦ،
ﻧﺸﺖ ﺁﻥ ﺑﻪ ﮐﻤﺘﺮ ﺍﺯ ﺳﺎﻟﯿﺎﻧﻪ 0.5%ﺑﺮﺳﺪ .ﺍﯾﻦ ﺑﺎﻋﺚ ﻋﺮﺿﻪ ﺛﺎﺑﺖ
ﻣﺮﺍﺣﻠﯽ ﮔﺎﻡﺑﻪﮔﺎﻡ ﺗﺎ ﺳــﺎﻝ 2030ﻣﺸــﺨﺺ ﺷﺪﻧﺪ .ﺩﺭ ﺩﺳﺎﻣﺒﺮ
HCFC - 22ﺍﺯ ﺗﺠﻬﯿﺰﺍﺕ ﻣﯽﺷــﻮﺩ .ﺳــﺎﺑﻖ ﺑﺮﺍﯾﻦ ،ﻧﺸﺖ ﺑﯿﻦ
3.1% ،1995ﺑــﻪ 2.8%ﮐﺎﻫﺶ ﯾﺎﻓﺘــﻪ ﻭ ﻣﺮﺣﻠﻪﺑﻨﺪﯼ ﺟﺪﯾﺪ ﺗﺎ
18% - 15%ﺩﺭ ﺳﺎﻝ ﺑﻮﺩ.
ﺳﺎﻝ ،2020ﻣﻘﺪﺍﺭ ﺍﻧﺪﮎ 1.2%ﻣﺎﺯﺍﺩ ﺭﺍ ﺗﺎ 2030ﺑﺎﻗﯽ ﮔﺬﺍﺷﺘﻪ
● ﻗﺎﻧــﻮﻥ ﻫــﻮﺍﯼ ﭘﺎﮎ ﺍﯾــﺎﻻﺕ ﻣﺘﺤﺪﻩ ﺗﺼﺮﯾــﺢ ﻣﯽﮐﻨﺪ ﮐﻪ
ﺍﺳﺖ .ﺑﺮﺍﯼ ﮐﺸﻮﺭﻫﺎﯼ ﺩﺭ ﺣﺎﻝ ﺗﻮﺳﻌﻪ ،ﻣﺼﺮﻑ CFCﺩﺭ 2016
HCFCﭘﯿﺶ ﺍﺯ ﺁﻥﮐــﻪ ﺑﻪ ﺑﺎﺯﺍﺭ ﺑﺮﮔﺮﺩﺩ ،ﺑﺎﯾﺪ ﺑﻪ ﮔﻮﻧﻪﺍﯼ ﻗﺎﻧﻮﻧﯽ
ﭘﻮﺷﺶ ﺩﺍﺩﻩ ﺷﺪﻩ ﻭ ﺗﺎ 2040ﻣﺮﺣﻠﻪﺑﻨﺪﯼ ﻣﯽﺷﻮﺩ.
ﺍﺣﯿﺎ ﻭ ﺑﺎﺯﯾﺎﺑﯽ ﺷﺪﻩ ﻭ ﺑﻪ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻣﻨﺎﺳﺒﯽ ﺩﺳﺖ ﯾﺎﺑﺪ )ﺭﺍﻫﻨﻤﺎﯼ
ﻧﮕﺎﻫﯽ ﺑﻪ HCFC - 22ﺩﺭ ﺍﺭﺗﺒﺎﻁ ﺑﺎ ﺍﯾﻦ ﻓﻬﺮﺳــﺖﺑﻨﺪﯼ ﺑﻪ ﻣﻮﺍﺭﺩ ﺯﯾﺮ ﻣﯽﭘﺮﺩﺍﺯﺩ. ● ﺗﻮﻟﯿﺪ ﻓﻌﻠﯽ ﻭ ﮔﺬﺷــﺘﻪ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸــﯽ ﺩﺭ ﺗﺼﻮﯾﺮ )(1 ﻧﺸــﺎﻥ ﺩﺍﺩﻩ ﺷﺪﻩ ﺍﺳــﺖ .ﺩﺭ ﻣﻮﺭﺩ ،HCFCﺍﯾﻦ ﺍﻣﺮ ﺑﺮ ﺍﺳﺎﺱ ﻋﺮﺿﻪ ﺁﯾﻨﺪﻩ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸﯽ ﺑﺎﺯﯾﺎﻓﺘﯽ ﻭ ﺍﺣﯿﺎﺷﺪﻩ ﺩﺭ ﺗﺠﻬﯿﺰﺍﺕ ● ﺩﺭ ﺍﻏﻠﺐ ﮐﺸــﻮﺭﻫﺎ ﻧﻤﯽﺗﻮﺍﻥ HCFC - 22ﺭﺍ ﺩﺭ ﺍﺗﻤﺴﻔﺮ ﺁﺯﺍﺩ ﮐﺮﺩ) .ﺑــﺮﺍﯼ ﻣﺜﺎﻝ ،ﻗﺎﻧﻮﻥ ﻫﻮﺍﯼ ﭘﺎﮎ ﺍﯾﺎﻻﺕ ﻣﺘﺤﺪﻩ ،ﻋﺪﻡ ﺍﻧﺘﺸﺎﺭ CFC / HCFCﭘﺲ ﺍﺯ .(95 / 15 / 11ﻋﺪﻡ ﺍﻧﺘﺸﺎﺭ ﺑﻪ
● ﺑﻪ ﺩﻟﯿﻞ ﺣﺮﮐﺖ ﺑﺎﺯﺍﺭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺧﺎﻧﮕﯽ ﺑﻪ ﺳﻤﺖ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸﯽ ﻣﺎﻧﻨﺪ R - 410 aﻭ ﺣﺮﮐﺖ ﭼﯿﻠﺮﻫﺎﯼ ﻣﺮﮐﺰﮔﺮﯾﺰ ﺑﺰﺭﮒ ﺑﻪ ﺳــﻤﺖ ،HFC - 134 aﻣﻨﺎﺑﻊ ﺍﺣﯿﺎ /ﺑﺎﺯﯾﺎﻓﺖ HCFC - 22 ﻋﻤﻼ ﺍﻓﺰﺍﯾﺶ ﯾﺎﻓﺘﻪ ﻭ ﺑﻪ ﻣﻨﺎﺑﻊ ﻣﺎ ﺍﻓﺰﻭﺩﻩ ﻣﯽﺷﻮﻧﺪ. ● ﺩﺳﺘﺮﺳﯽ ﺑﻪ ﻋﻨﺎﺻﺮﯼ ﺟﺎﯾﮕﺰﯾﻦ ﻣﺎﻧﻨﺪ ﮐﻤﭙﺮﺳﻮﺭﻫﺎﯾﯽ ﺑﺮﺍﯼ ﺑــﺎﺯﺍﺭ HCFC - 22ﺑﺎﯾﺪ ﺩﺭﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷــﻮﺩ .ﺑﺪﻭﻥ ﻃﺮﺡﻫﺎﯼ ﺟﺪﯾﺪ ،ﺗﻤﺮﮐﺰ ﺑﺮ ﻣﺎﯾﻌﺎﺕ ﺳﺮﻣﺎﯾﺸﯽ ﺟﺪﯾﺪ ﺑﻪ ﻭﺳﯿﻠﻪ ﯾﮏ ﺳﺎﺯﻧﺪﻩ ﺑﺰﺭﮒ ﺻــﻮﺭﺕ ﻣﯽﮔﯿﺮﺩ .ﺍﯾﻦ ﻣﺪﻝﻫﺎﯼ ﮐﻮﯾﻞ ﻭ ﮐﻤﭙﺮﺳــﻮﺭﻫﺎﯼ
ﺗﺼﻮﯾﺮ ) (1ﺗﻮﻟﯿﺪ ﺳﺎﻟﯿﺎﻧﻪ ﻓﻠﻮﺭﻭﮐﺮﺑﻦﻫﺎ
ﺟﺪﯾــﺪ ﻭ ﺧﺎﺹ ﺭﺍ ﻧﻤﯽﺗﻮﺍﻥ ﺍﺯ ﻧﻤﺎﯾﻨﺪﮔﯽ ﻣﺤﻠﯽ ﺧﻮﺩ ﺑﻪ ﺩﺳــﺖ ﺁﻭﺭﺩ .ﺍﯾــﻦ ﺍﻣﺮ ﺑﻪﻭﯾــﮋﻩ ﺩﺭ ﻣﻮﺍﺭﺩ ﺣﻤﻞﻭﻧﻘﻞ ﺗﺠﺎﺭﯼ ﺳﺮﻣﺎﯾﺸــﯽ ﻫﺰﺍﺭﺍﻥ ﺗﻦ
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ ﻧﻤﺎﻳﻨﺪﻩ ﺍﻧﺤﺼﺎﺭﻯ ﻳﺎﺯﺍﻛﻰ ژﺍﭘﻦ ﺩﺭ ﺍﻳﺮﺍﻥ
ﺑﺎﺯﯾﺎﺑﯽ ﺻﻨﻌﺘﯽ ﻭ ﺍﺳــﺘﺎﻧﺪﺍﺭﺩ (ARI - 700، IRG - 2ﺗﺎ ﺍﺯ ﺍﯾﻦ ﻣﻨﺒﻊ ﺑﺰﺭﮒ ﻭﺭﺍﯼ ،2020ﺍﻃﻤﯿﻨﺎﻥ ﺣﺎﺻﻞ ﮐﺮﺩ.
ﻧﺼﺐ ﺷﺪﻩ ﺍﺳﺖ.
ﺗﻠﻔﻦ88739880-2:
ﺍﯾﻦ ﻣﻌﻨﯽ ﺍﺳﺖ ﮐﻪ ﻋﺮﺿﻪ ،ﺛﺎﺑﺖ ﺑﺎﻗﯽ ﺧﻮﺍﻫﺪ ﻣﺎﻧﺪ.
ﻣﺎﻧﻨﺪ ﺳﺮﻣﺎﯾﺶ ﮐﺎﻣﯿﻮﻥﻫﺎ ﻭ ﺗﺮﯾﻠﺮﻫﺎ ﮐﻪ ﺧﺪﻣﺎﺕ ﺑﯿﻦﺍﻟﻤﻠﻠﯽ ،ﺩﺭ ﻫﺮ ﺷﻬﺮ ﺑﺰﺭﮔﯽ ﻧﯿﺎﺯﻣﻨﺪ ﺁﻥﻫﺎﺳﺖ ،ﺍﻫﻤﯿﺖ ﺯﯾﺎﺩﯼ ﺩﺍﺭﺩ. ﺑﺎ ﻣﻼﺣﻈﻪ ﻧﮕﺎﻫﯽ ﺑﻪ ،HCFC - 22ﺍﯾﻦ ﻣﺴﺎﻟﻪ ﺑﺰﺭﮒ ﺁﺷﮑﺎﺭ ﻣﯽﺷــﻮﺩ ﮐﻪ HCFC - 22ﺩﺭ ﺳــﺎﻝ 2030ﺩﯾﮕﺮ ﺗﻮﻟﯿﺪ ﻧﺸﺪﻩ ﻭ ﭼﻨﯿﻦ ﺣﺠﻢ ﺑﺰﺭﮔﯽ ﺑﺎﯾﺪ ﺑﺎ ﻣﻮﺍﺩﯼ ﮐﻪ ﺑﻪ ﻣﺤﯿﻂ ﺯﯾﺴــﺖ ﺁﺳﯿﺐ
ﺳﺎﻝ ﻛﺘﺎﺏ
ﺗﻬﻮﻳﻪﺍﺭﻭﻧﺪ ﻳﻜﺘﺎﺗﻬﻮﻳﻪ ﻳﻜﺘﺎ ﺍﺭﻭﻧﺪ
»ﺩﺳﺘﻴﺎﺭ ﻣﻬﻨﺪﺱ ﺗﺎﺳﻴﺴﺎﺕ« ﺗﻠﻔﻦ22885647-50 :
ﺗﻬﻮﻳﻪﻣﻄﺒﻮﻉ ﺍﺻﺎﻟﺖﺗﻬﻮﻳﻪ ﺍﺻﺎﻟﺖ ﻣﻄﺒﻮﻉ
ﻧﺮﺳﺎﻧﻨﺪ ،ﺟﺎﯾﮕﺰﯾﻦ ﺷﻮﺩ.
ﻳﻜﺘﺎ ﺗﻬﻮﻳﻪ ﺍﺭﻭﻧﺪ
ﺍﺻﺎﻟﺖ ﺗﻬﻮﻳﻪ ﻣﻄﺒﻮﻉ
ﭼﻴﻠﺮ ﺟﺬﺑﻰ ﮔﺎﺯﺳﻮﺯ
«¦®¥¢ë² § ÐëË» § «Ä· ©Í¶» Ú« ëë » Ä ®Ù ª½ ¦ëÓ ëÕ : ¤¦ÜÕ ß§¦Æ § ¥¸È¤ ¦ÜÕ «´¤¦± À¤¢µ » Ú«¾¢ë±¿¶ À¤¢µ » Ú« ¸§¦¹ § ·¥¦Ï» Ä ®À¤¦ëÜÕ »« ®Ä¸È¤ § ¸È¤» § «¥¸Èë¤ ¦±«» Ú«Ä· ©Í¶ ¦ëÒæ » Ú«ÀÝ¢Ý áëÍí « °î¦¹§°Ò Õ Ò¶ ïÖ¢¶×Ä ®ß·§¸ß´½·¥ÈƦ¹ ÀÕ WWW.YAZDA.IR-----------WWW.HVAC.IR
Ù× ¹ £¤ ¶¦Æ § £¤ ¶¦ Úà է·´ ® Ä ®Çª ﺑﻬﺮﺍﻡ ﺧﺎﮐﭙﻮﺭ /ﻭﺯﯾﺮﯼ ۱۱۰۴ /ﺻﻔﺤﻪ ۱۱۹۰۰ /ﺗﻮﻣﺎﻥ
¯¦®¬ (¡¢ £¤¥¦¤§) ¨ ©ª« ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳﺖ /ﻭﺯﯾﺮﯼ ۷۶۰ /ﺻﻔﺤﻪ ۱۶۰۰۰ / ﺗﻮﻣﺎﻥ
¶°Õ ·Ù× Ä ®ÀÒ±Ó ° ´µ Syed R. Qasim, Edward M. Motely and Guang Zhu /ﻣﺤﻤﺪﺭﺿﺎ ﺍﻓﻀﻠﯽ /ﻭﺯﯾﺮﯼ ۹۸۶/ﺻﻔﺤﻪ ۱۸۰۰۰/ﺗﻮﻣﺎﻥ
¯¦®¬ ¨ ©ª« °± ² ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳﺖ /ﭘﺎﻟﺘﻮﯾﯽ ۴۳۲ /ﺻﻔﺤﻪ ۵۵۰۰ / ﺗﻮﻣﺎﻥ
¶·¢ Õ × °Õ ± ﺣﺴــﻦ ﻟﻄﻔﯽ ﺭﺿﻮﺍﻧﯽ ،ﺟﺎﻣﺎﺳــﺐ ﭘﯿﺮﮐﻨﺪﯼ /ﻭﺯﯾﺮﯼ / ۲۵۶ﺻﻔﺤﻪ ۵۰۰۰ /ﺗﻮﻣﺎﻥ
¸ ³´µ¶ · ª ﻣﺤﻤﺪﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ /ﻭﺯﯾﺮﯼ ۳۰۴ /ﺻﻔﺤﻪ ۶۰۰۰ /ﺗﻮﻣﺎﻥ
¸ À¶ ª ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﭘﺎﻟﺘﻮﯾﯽ ۳۶۸ /ﺻﻔﺤﻪ ۸۰۰۰ / ﺗﻮﻣﺎﻥ
¼ »¦ °¹º² ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳﺖ /ﻭﺯﯾﺮﯼ ۵۱۲ /ﺻﻔﺤﻪ ۱۱۵۰۰ / ﺗﻮﻣﺎﻥ
¶¦ÄÖ¢Ò² § Õ¢ ڦت ¥ ̶ ² ̲ ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﻭﺯﯾﺮﯼ ۶۸۸ /ﺻﻔﺤﻪ ۱۲۹۰۰ /ﺗﻮﻣﺎﻥ
¦½¢ª ¥ ¾¢±¿¶ À¤¢µ ﺍﺳــﺘﻮﮐﺮ /ﻣﺤﻤـﺪ ﺷﻬﺮﺥﺧﺎﻧﯽ /ﻭﺯﯾﺮﯼ ۲۶۴ /ﺻﻔﺤﻪ / ۷۵۰۰ﺗﻮﻣﺎﻥ
·¦Øª ¥ Ä·¥´µÛÕ § ¦ ©Í § °Ï¥¦Ë Ä ©®¥ ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﻭﺯﯾﺮﯼ ۳۲۰ /ﺻﻔﺤﻪ ۹۰۰۰ /ﺗﻮﻣﺎﻥ
HVAC ·¸ °©¤¥ § á ¶¥ ﻟﺌــﻮ ﻣﺎﯾﺮ /ﭘﯿﻤﺎﻥ ﺯﺭﺍﻓﺸــﺎﻥ /ﺭﻗﻌﯽ ۸۸ /ﺻﻔﺤــﻪ ۱۵۰۰ / ﺗﻮﻣﺎﻥ ¶¦´¤¦± § À¤¢µ °± ² ̲ ﭘﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﻣﺤﻤﺪ ﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ /ﺟﯿﺒﯽ ۳۰۴ /ﺻﻔﺤﻪ ۲۵۰۰ /ﺗﻮﻣﺎﻥ ¶¦HVAC/R ⤧¦ § °¹ ¤ã Ñ °± ² ̲ ﭘﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﺳــﻠﯿﻤﺎﻥ ﭼﮕﯿﻨﯽ /ﺟﯿﺒﯽ ۲۰۰ /ﺻﻔﺤﻪ / ۲۲۰۰ﺗﻮﻣﺎﻥ ¶¦¾¢±¿¶ À¤¢µ § £¤ ¶¦Æ °± ² ̲ )ﻭﯾﺮﺍﺳﺖ ﺩﻭﻡ( ﭘــﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘــﺎﻥ /ﺟﯿﺒﯽ ۳۵۲ / ﺻﻔﺤﻪ ۳۳۰۰ /ﺗﻮﻣﺎﻥ ¶¦Ä· ÒÓ¢² °± ² ̲ ﺟﯿﻤﺰ ﺑﺮﻭﻣﺒﺎﺥ ،ﺭﮐﺲ ﻣﯿﻠﺮ /ﺣﺴــﻦ ﻣﺤﻤﺪﯼ /ﺟﯿﺒﯽ / ۴۶۴ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ
¾¢±¿¶ À¤¢µ °¤¥¦²¥ ÒÕ ﻣﯿﺸﻞ ﮐﯿﺴﯽ ،ﺭﺩﻭﻭﺩ ﮐﺎﺭﺩﻥ ﻭ ﺩﺍﮔﻼﺱ ﻫﻨﺴﻦ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۱۱۲ /ﺻﻔﺤﻪ ۲۲۰۰ /ﺗﻮﻣﺎﻥ
¶¦°Ü½ÀÝ¢Ý °± ² ̲ ﭘــﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘــﺎﻥ /ﺟﯿﺒﯽ ۳۶۸ / ﺻﻔﺤﻪ ۳۳۰۰ /ﺗﻮﻣﺎﻥ
°Ü½ÀÝ¢Ý °¤¥¦²¥ ÒÕ ﻣﯿﺸﻞ ﮐﯿﺴﯽ ،ﺭﺩﻭﻭﺩ ﮐﺎﺭﺩﻥ ﻭ ﺩﺍﮔﻼﺱ ﻫﻨﺴﻦ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۱۰۴ /ﺻﻔﺤﻪ ۲۲۰۰ /ﺗﻮﻣﺎﻥ
HVAC ·¸ Å¢ÊÏ £¤¥È¯¥ ﮐﺮﯾــﺲ ﺭﯾﮏ /ﻧﯿﺮﻩ ﺷﻤﺸــﯿﺮﯼ /ﺭﻗﻌــﯽ ۱۰۴ /ﺻﻔﺤﻪ / ۱۵۰۰ﺗﻮﻣﺎﻥ
¶¾¢±¿¶ À¤¢µ Þ¦ª½ °Õ ± ﻟﺌﻮ ﻣﺎﯾﺮ /ﺳــﻠﯿﻤﺎﻥ ﭼﮕﯿﻨﯽ /ﺭﻗﻌﯽ ۹۶ /ﺻﻔﺤﻪ ۲۰۰۰ / ﺗﻮﻣﺎﻥ
¯àÒÓV Ä ®À© § ®ä ﻟﺌــﻮ ﻣﺎﯾﺮ /ﻣﯿــﻼﺩ ﺗﯿﻤﻮﺭﯼ /ﺭﻗﻌــﯽ ۱۱۲ /ﺻﻔﺤﻪ ۱۸۰۰ / ﺗﻮﻣﺎﻥ
°¹× Ä ®¦Ý¢½ § Ħ ر Ä ®Çª ﺟــﯽ .ﺩﯼ .ﭘﺎﻟﻤــﺮ /ﺛﻤﺮ ﺗﺮﺍﺑﯽ ﮐﺮﻣﺎﻧﺸــﺎﻩ /ﺭﻗﻌﯽ ۱۴۴ / ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ
®Þ Õ ½ ·¸ ¥¢® ¨ ¤¦² ﻟﺌــﻮ ﻣﺎﯾﺮ /ﻣﯿﻼﺩ ﺗﯿﻤﻮﺭﯼ /ﺭﻗﻌــﯽ ۱۲۰ /ﺻﻔﺤﻪ ۱۸۰۰ / ﺗﻮﻣﺎﻥ
¶Þ Õ ½ ÀÒ±Ó ¸·§×¦¹ § ߦª ﺟﺎﻥ ﮔ َﻠﺪ ﺍﺳﺘﻮﻥ /ﭘﮋﻣﺎﻥ ﺭﺣﻤﺎﻧﯽﻧﯿﺎ /ﺭﻗﻌﯽ ۹۶ /ﺻﻔﺤﻪ ۱۸۰۰ /ﺗﻮﻣﺎﻥ
½ (IAQ) à«¥¸ Ä¥¢® á æ ﺟــﺎﻥ ﺍﻝ .ﺑﺮﮒﮔﺮﻥ /ﺭﺍﻣﯿﻦ ﺗﺎﺑــﺎﻥ /ﺭﻗﻌﯽ ۱۵۲ /ﺻﻔﺤﻪ ۲۰۰۰ /ﺗﻮﻣﺎﻥ
) Τ¦Ï ¡ÐÑ¥ Ä ®Çªﻭﯾﺮﺍﯾﺶ ﺩﻭﻡ( ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳﺖ /ﺭﻗﻌﯽ ۲۶۴ /ﺻﻔﺤﻪ ۶۵۰۰ /ﺗﻮﻣﺎﻥ
§ ¾¢±¿¶ À¤¢µ ·¸ Ħ ÆßÖ¥´Õ¥ ठﻟﺌــﻮ ﻣﺎﯾﺮ ،ﺍﭺ .ﻟﯿﻦ ﻣﺎﯾــﺮ /ﺭﺍﻣﯿﻦ ﺗﺎﺑــﺎﻥ /ﺭﻗﻌﯽ ۱۲۰ / ﺻﻔﺤﻪ ۲۵۰۰ /ﺗﻮﻣﺎﻥ
HVAC Ä ®ä Ò Ä¥¦¹ ´¤¦± ﻟﺌــﻮ ﻣﺎﯾــﺮ /ﺭﺍﻣﯿﻦ ﺗﺎﺑــﺎﻥ /ﺭﻗﻌﯽ ۱۱۲ /ﺻﻔﺤــﻪ ۱۸۰۰ / ﺗﻮﻣﺎﻥ
䦪¶§¦Ò¤ ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﺭﻗﻌﯽ ۳۶۴ /ﺻﻔﺤﻪ ۶۰۰۰ / ﺗﻮﻣﺎﻥ
߸ ¨ ¹Ö À¹ ¾¢±¿¶ À¤¢µ ﻟﺌــﻮ ﻣﺎﯾﺮ /ﭘﯿﻤﺎﻥ ﺟﻌﻔﺮﯾــﺎﻥ /ﺭﻗﻌﯽ ۱۰۴ /ﺻﻔﺤﻪ ۱۸۰۰ / ﺗﻮﻣﺎﻥ
¶¾¢±¿¶ À¤¢µ °ªÜÛÕ¥¦ ± ç ﺁﺭﺗﻮﺭ ﺍِﯼ .ﺑﻞ /ﺭﻗﻌﯽ ۲۲۴ /ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ
«Ä´ Ó·¢« ÄÔ¦Õ¥ Ö¢¶×¸¢ ﺭﯾـــﮏ ﺩﯼﮔـﺎﻧﺘﺮ /ﻣﺤﻤﺪﺭﺿﺎ ﺷــﺎﻫﯽ /ﻭﺯﯾــﺮﯼ۴۴۸ / ﺻﻔﺤﻪ ۱۰۰۰۰ /ﺗﻮﻣﺎﻥ
°©½¥¦ Ä ®Çª ﺟــﺎﻥ ﺗﺎﻣﮋﯾﮏ /ﭘﯿﻤﺎﻥ ﺟﻌﻔﺮﯾــﺎﻥ /ﺭﻗﻌﯽ ۶۴ /ﺻﻔﺤﻪ / ۱۵۰۰ﺗﻮﻣﺎﻥ
) · ع À» ﻭﯾﺮﺍﯾﺶ ﺩﻭﻡ( ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﺭﻗﻌــﯽ ۲۹۶ /ﺻﻔﺤﻪ ۷۰۰۰ / ﺗﻮﻣﺎﻥ
¾¢±¿¶ À¤¢µ Þ¦ª½ § Ŧ¹ ﭘﯿﺘﺮ ﺍﺱ .ﮐﻮﺭﺗﯿﺲ ﻭ ﻧﯿﻮﺗﻦ ﺑﺮﺙ /ﻣﺤﻤﺪﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ / ﺭﻗﻌﯽ ۱۵۲ /ﺻﻔﺤﻪ ۲۸۰۰ /ﺗﻮﻣﺎﻥ
® ´·§¸ ®Á©Â à ¶ ¤ ﭘﺮﻭﻓﺴــﻮﺭ ﮐﺮﯾﺴــﺘﻮﻓﺮ ﺍﺭﻟﺰ ﺑﺮﻧﻦ /ﻣﺤﻤـﺪ ﺷﻬﺮﺥﺧﺎﻧﯽ / ﻭﺯﯾﺮﯼ ۳۳۶ /ﺻﻔﺤﻪ ۷۰۰۰ /ﺗﻮﻣﺎﻥ ¾¢±¿¶ À¤¢µ Ä¥¦¹ Ŧ¹ ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﺭﺣﻠﯽ ۵۰۸ /ﺻﻔﺤﻪ ۱۷۰۰۰ / ﺗﻮﻣﺎﻥ ·¾¢±¿¶ À¤¢µ § £¤ ¶¦Æ ° ´µ¶ Ä ©®¥ ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﺭﻗﻌﯽ ۳۰۴ /ﺻﻔﺤﻪ ۶۵۰۰ / ﺗﻮﻣﺎﻥ ®Çª § ¥È µÉ Ä´¹ÀÊ±Ë ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﺭﻗﻌﯽ ۱۶۸ /ﺻﻔﺤﻪ ۶۵۰۰ / ﺗﻮﻣﺎﻥ ¶¦(¡§¸ £¤¥¦¤§) ̤¦ Ͳ¥ ﻣﺤﻤﺪﺭﺿﺎ ﺳﻠﻄﺎﻧﺪﻭﺳــﺖ /ﺭﻗﻌﯽ ۸۴۰ /ﺻﻔﺤﻪ ۱۷۰۰۰ / ﺗﻮﻣﺎﻥ
¾¢±¿¶ À¤¢µ ·¸ (VAV) ¦ 誶 Ä¥¢® ÇÉÏ Ä ®Çª ﻟﺌــﻮ ﻣﺎﯾﺮ /ﻣﺰﺩﮎ ﺻﺪﺭﯼ ﺍﻓﺸــﺎﺭ /ﺭﻗﻌــﯽ ۸۸ /ﺻﻔﺤﻪ / ۱۵۰۰ﺗﻮﻣﺎﻥ ¼·¸ ¾¢±¿¶ À¤¢µ ¥È µÉ ãéÕ Ä¥¦¹ ÀªÒÕ Ã¤ § ൠ«°Õ¢Ò ¶ Ä ®¨ ©ª َﻟــﺮﯼ ﮔﺎﺭﺩﻧــﺮ ﻭ ﻟﺌﻮ ﻣﺎﯾــﺮ /ﺭﺍﻣﯿﻦ ﺗﺎﺑــﺎﻥ /ﺭﻗﻌﯽ ۱۲۸ / ﺻﻔﺤﻪ ۲۵۰۰ /ﺗﻮﻣﺎﻥ
Þ Õ ½ Ä ®¢ÛÝ¥ ﻟﺌﻮ ﻣﺎﯾﺮ /ﭘﯿﻤﺎﻥ ﺟﻌﻔﺮﯾﺎﻥ /ﺭﻗﻌﯽ ۱۴۴ /ﺻﻔﺤﻪ ۲۳۰۰ /ﺗﻮﻣﺎﻥ ׶ ¸Ù× ÄÖ ß ﮐﺎﻟﯿﻦ ﻓﺮﺍﯾﻦ ﻭ ﺭﯾﭽﺎﺭﺩ ﺗﯽﺑﻠﯿﮏ /ﻣﻨﺼﻮﺭ ﺣﺴــﯿﻨﯽ ﺍﺭﺍﻧﯽ /ﺭﻗﻌﯽ ۱۲۸ /ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ °¤¥ºô ¸¥¢¶ Ä¥¦¹ °Ü¤ ¶¦ ﺍ .ﺩﯾﻨﺴــﺮ /ﻧﯿﺮﻩ ﺷﻤﺸﯿﺮﯼ /ﺭﻗﻌﯽ ۲۹۶ /ﺻﻔﺤﻪ ۵۰۰۰ / ﺗﻮﻣﺎﻥ ×¾¢±¿¶ À¤¢µ Ä ®Çª âÕõ ¹ § Ç ö Ú£¤ ¶Ö ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۳۶۸ /ﺻﻔﺤﻪ ۴۸۰۰ /ﺗﻮﻣﺎﻥ °ÓÖ¢¶× Ƚ¥¦¶ Ä¥¦¹ ¾¢±¿¶ À¤¢µ ﺍﺭﯾــﮏ ﮐﻮﻟﺪﺭﺍﭖ ﻭ ﭘــﺖ ﺟﺎﮐﻮﺑﺰ /ﺭﺍﻣﯿﻦ ﺗﺎﺑــﺎﻥ /ﺭﻗﻌﯽ/ ۳۰۴ﺻﻔﺤﻪ ۶۰۰۰ /ﺗﻮﻣﺎﻥ ¶Ä¥Àçæí ° ·¥¦Ï Ä ®Þ´± ﺍﻝ .ﻭﺍﻧﮕﻪ ،ﺏ .ﺳﺎﻧﺪﻥ ،ﺍﺭ .ﻡ .ﻣﻨﮕﻠﯿﮏ /ﺣﺴﻦ ﻣﺤﻤﺪﯼ /ﺭﻗﻌﯽ ۳۴۴ /ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ ¾¢±¿¶ À¤¢µ Þ¦ª½ Ä ®Çª ﺭﺍﺟﺮ ﻫﯿﻨﺲ ،ﺩﺍﮔﻼﺱ ﻫﯿﺘﻞ /ﺻﺎﺩﻕ ﺻﻤﺪﯼ ،ﺳﻠﯿﻤﺎﻥ ﭼﮕﯿﻨﯽ /ﺭﻗﻌﯽ ۳۶۸ /ﺻﻔﺤﻪ ۶۰۰۰ /ﺗﻮﻣﺎﻥ °Ü½ÀÝ¢Ý Ä ®ÀÒ±Ó °¹ ¤Ö·¥ § ° ·Ö ¹ ﺟﯿــﻞ .ﺍﻝ .ﺗﯿﻠــﻮﺭ /ﻧﯿﺮﻩ ﺷﻤﺸــﯿﺮﯼ ،ﺭﻭﺡﺍ ...ﻭﺍﺻﻒ / ﺭﻗﻌﯽ ۲۰۰ /ﺻﻔﺤﻪ ۳۵۰۰ /ﺗﻮﻣﺎﻥ ¯(¡§¸ £¤¥¦¤§) Ä·¢ç¶ ¨ ¤¦² Ä ®·¢ ¦÷©½ § ®ä ﺍ .ﺏ .ﻣﮑﻨــﺰﯼ /ﻣﺤﻤــﺪ ﺷــﻬﺮﺥﺧﺎﻧﯽ /ﺭﻗﻌــﯽ ۳۴۴ / ﺻﻔﺤﻪ ۹۰۰۰ /ﺗﻮﻣﺎﻥ ¯ »¥¢® ÄÖ ß¸ ¶× § ®¦ª ﻭﯾﻠﯿﺎﻡ ﺗﺮﻧﺮ ،ﮐﺎﯾﺮﻭﻥ ﺍﻭﮐﺎﻧﻞ ،ﻭﻻﺩﯾﺴﻼﻭ ﺟﺎﻥ ﮐﻮﻭﺍﻟﺴﮑﯽ ﻭ ﻭﯾﻠﯿــﺎﻡ ﺑﺎﻧﻔﻠﺚ /ﻣﻨﺼﻮﺭ ﺣﺴــﯿﻨﯽ ﺍﺭﺍﻧﯽ /ﺭﻗﻌﯽ۱۷۶ / ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ ·ASHRAE °± ² Ä ©®¥ ﻣﺤﻤﺪﺭﺿﺎ ﺭﺯﺍﻗﯽ ﺍﺻﻔﻬﺎﻧﯽ /ﺭﻗﻌﯽ ۳۳۶ /ﺻﻔﺤﻪ ۳۸۰۰ / ﺗﻮﻣﺎﻥ DUCTSIZE,Ä ë®·¥È¯¥¡¦Õ
·§°²· « Ä ® ¯ °¤ Ó ﺩﯾﻮﯾﺪ ﻣﮏﻧﺎﯾﺮ /ﻣﺎﺯﯾﺎﺭ ﻣﻮﻟﻮﯼ ،ﺳﺎﻧﺎﺯ ﭘﺬﯾﺮﺍ ،ﺳﭙﯿﺪﻩ ﭘﺬﯾﺮﺍ/ ﻭﺯﯾﺮﯼ ۳۹۶ /ﺻﻔﺤﻪ ۸۰۰۰ /ﺗﻮﻣﺎﻥ ¸ (Ŧ¹ ° ´µ¶ Ä ©®¥·) Ŧ¹ À¶ ª ﺭﮐﺲ ﻣﯿﻠﺮ /ﻣﺎﺯﯾﺎﺭ ﻣﻮﻟﻮﯼ /ﺭﻗﻌﯽ ۳۵۲ /ﺻﻔﺤﻪ ۶۵۰۰ / ﺗﻮﻣﺎﻥ ¶Å¦¹ ± ç ﮐﺮﯾﺲ ﮐﯿﭽﺮ ،ﺍﯼ .ﺟﯽ .ﻭﺍﺗﮑﯿﻨﺰ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘﺎﻥ /ﺭﻗﻌﯽ ۳۳۶ /ﺻﻔﺤﻪ ۶۵۰۰ /ﺗﻮﻣﺎﻥ ¯ (FTTH) ÞÖ ¶ ¦± ¯ Ä·§ ¯ Ä·¢Õ ¦± ﭘــﺎﻭﻝ ﮔﺮﯾﻦ /ﺟﻤﺎﻝ ﺻﻮﻓﯿﻪ /ﺭﻗﻌﯽ ۱۶۸ /ﺻﻔﺤﻪ ۴۰۰۰ / ﺗﻮﻣﺎﻥ ¶¦¦¤¢é § ¥´í °± ² ̲ ﭘﺎﻝ ﺭﻭﺯﻧﺒــﺮﮒ /ﺍﺑﺮﺍﻫﯿﻢ ﭼﮕﯿﻨﯽ /ﺟﯿﺒﯽ ۳۸۴ /ﺻﻔﺤﻪ ۳۳۰۰ /ﺗﻮﻣﺎﻥ ¶¦Å¦ë¹ °± ² ̲ ﭘــﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘــﺎﻥ /ﺟﯿﺒﯽ۴۰۰ / ﺻﻔﺤﻪ ۴۲۰۰ /ﺗﻮﻣﺎﻥ ¶¦°Ò¤¦ªÒÝ¥ Ä ®·¢ ¢¶ °± ² ̲ ﭘــﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘــﺎﻥ /ﺟﯿﺒﯽ ۴۰۰ / ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ ¶´ ®¨× Ä·¥´µÛÕ § °Ò¤¦ªÒÝ¥ Ä ®·¥ ﭘــﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﺭﺍﻣﯿــﻦ ﺗﺎﺑﺎﻥ /ﺟﯿﺒــﯽ ۲۲۴ /ﺻﻔﺤﻪ / ۲۵۰۰ﺗﻮﻣﺎﻥ °Ò¤¦ªÒÝ¥ Ä ®·¥´¶ ¤È² ﭘــﺎﻝ ﺭﻭﺯﻧﺒﺮﮒ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘــﺎﻥ /ﺟﯿﺒﯽ۳۸۴ / ﺻﻔﺤﻪ ۳۵۰۰ /ﺗﻮﻣﺎﻥ Ŧ¹ °¤¥¦²¥ ÒÕ ﻣﯿﺸﻞ ﮐﯿﺴﯽ ،ﺭﺩﻭﻭﺩ ﮐﺎﺭﺩﻥ ﻭ ﺩﺍﮔﻼﺱ ﻫﻨﺴﻦ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۱۱۲ /ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ ×Ŧ¹ Ä ®·¥´¶ °¹ ¤ã Ñ § £¤ ¶Ö ﺡ .ﺑﺮﻭﮎ ﺍﺳﺘﺎﻓﺮ -ﺟﺎﻥ.ﺍ .ﺗﺮﯾﺴﺘﺮ /ﻣﺤﻤﺪﺗﻘﯽ ﺣﺴﻦﺯﺍﺩﻩ /ﺭﻗﻌﯽ ۱۱۲ /ﺻﻔﺤﻪ ۲۸۰۰ /ﺗﻮﻣﺎﻥ
·àë¶ ½ Ä ë©®¥ REFRIG, SPIPE ﻣﯿﺜﻢ ﺑﺎﺭﻓﺮﻭﺵ ،ﻋﻠﯿﺮﺿﺎ ﻧﯿﮑﺨﻮﺍﻩ ،ﻋﻠﯽ ﻧﯿﮑﻮﻧﯿﺎ /ﻭﺯﯾﺮﯼ/ ۲۴۸ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ
¶´°Ò Õ§¦ªÒÝ¥ Ä ®ß·¥È¯¥ § ®·¥ ﺟﯿﻤــﯽ ﮐﺘﯽ /ﻋﺒﺎﺱ ﺯﻧﺪﺑــﺎﻑ /ﺭﻗﻌﯽ ۱۴۴ /ﺻﻔﺤﻪ / ۴۰۰۰ﺗﻮﻣﺎﻥ
·Carrier·¥È¯¥¡¦Õ ච½ Ä ©®¥ ﻣﺤﻤﺪﺭﺿــﺎ ﺭﺯﺍﻗــﯽ ﺍﺻﻔﻬﺎﻧﯽ /ﻭﺯﯾــﺮﯼ ۴۸۸ /ﺻﻔﺤﻪ / ۸۵۰۰ﺗﻮﻣﺎﻥ
× ( ÉÕ § °©¤¥ Ä ©®¥·) °î¦¹À»Â § ·¢ Õ ﺗﺌﻮﺩﻭﺭ ﻟﯽ ﻭ ﺟﺎﻥ ﺩﺍﻧﺎﮔﯿﻮ /ﻣﺤﻤﺪﻋﻠﯽ ﺍﻟﻬﯿﺎﻥ /ﻭﺯﯾﺮﯼ/ ۴۱۶ﺻﻔﺤﻪ ۷۰۰۰ /ﺗﻮﻣﺎﻥ
·RHVAC, CHVAC Ä ®·¥È¯¥¡¦Õ ච½ Ä ©®¥ ﻣﯿﺜــﻢ ﺑﺎﺭﻓﺮﻭﺵ ،ﻋﻠﯽ ﻧﯿﮑﻮﻧﯿﺎ /ﺭﻗﻌــﯽ ۲۲۴ /ﺻﻔﺤﻪ / ۶۰۰۰ﺗﻮﻣﺎﻥ
°Ò¤¦ªÒÝ¥ Ä ®ÀÒ±Ó á æÏ ﮐﺮﯾﺴﺘﻒ ﭘﺮﯼ /ﺳﯿﺪ ﻣﺤﻤﻮﺩ ﺣﻖﺷﻨﺎﺱ /ﻭﺯﯾﺮﯼ ۴۳۲ / ﺻﻔﺤﻪ ۱۰۰۰۰ /ﺗﻮﻣﺎﻥ
·PIPE FLOW EXPERT ·¥È믥¡¦Õ ච½ Ä ©®¥ 2007 ﺭﻭﺡﺍ ...ﻭﺍﺻﻒ /ﺭﻗﻌﯽ ۱۷۶ /ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ
¾¢±¿¶ À¤¢µ Þ¦ª½ § Ŧ¹ ﭘﯿﺘﺮ ﺍﺱ .ﮐﻮﺭﺗﯿﺲ ﻭ ﻧﯿﻮﺗﻦ ﺑﺮﺙ /ﻣﺤﻤﺪﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ/ ﺭﻗﻌﯽ ۱۵۲ /ﺻﻔﺤﻪ ۲۸۰۰ /ﺗﻮﻣﺎﻥ
·¥È믥¡¦Õ ë¹ ¨ ©ª« ë ë °ëÏ¥¦Ë AutoCAD MEP ﻣﯿﺜﻢ ﺑـﺎﺭﻓﺮﻭﺵ ،ﻋﻠﯿﺮﺿﺎ ﻧﯿﮑﺨﻮﺍﻩ /ﻭﺯﯾﺮﯼ ۳۸۴ /ﺻﻔﺤﻪ ۹۵۰۰ /ﺗﻮﻣﺎﻥ
° ·¥¦Ï ß Æ§¦ Õ ﻣﺤﻤﺪﺣﺴﻦ ﺳﻌﯿﺪﯼ ،ﻣﺤﻤﺪﺭﺿﺎ ﻃﻼﯾﯽ /ﺭﺣﻠﯽ۴۶۴ / ﺻﻔﺤﻪ ۱۳۵۰۰ /ﺗﻮﻣﺎﻥ
¶¦Æ Þ ÊªÕ¥ ° ´µ¶ § Þ ¢Õ Õ ﺳﯿﺪﺷــﺮﻑﺍﻟﺪﯾﻦ ﺣﺴــﯿﻨﯽ /ﺭﻗﻌﯽ ۲۴۰ /ﺻﻔﺤﻪ ۵۵۰۰ / ﺗﻮﻣﺎﻥ
· ´Ï¥§ Ä ë®äÒ¶¦Æ£  ·¸ ¡ ë« áëæÕ Ä·¥ºÆÙ¢ë ¦ ¿Ê ﺍﺩﺍﺭﻩ ﭘﮋﻭﻫــﺶ ﻭ ﻓﻦﺁﻭﺭﯼ ﺷــﺮﮐﺖ ﭘﺎﻻﯾﺶ ﻧﻔﺖ ﺗﻬﺮﺍﻥ / ﺭﻗﻌﯽ ۱۲۰ /ﺻﻔﺤﻪ ۶۰۰۰ /ﺗﻮﻣﺎﻥ
´¤¦± ¥È µÉ ﺍِﯼ .ﺳــﯽ .ﺑﺮﺍﯾﺎﻧﺖ /ﻏﻼﻣﺮﺿﺎ ﺳــﺎﻻﺭﮐﯿﺎ /ﺭﻗﻌﯽ۲۶۴ / ﺻﻔﺤﻪ ۳۳۰۰ /ﺗﻮﻣﺎﻥ
°Í ±Ë Ö Æ ﺭﺍﮐﺶ ﺭﺍﺗﯽ /ﭘــﮕﺎﻩ ﺭﺿﺎﯾﯽ /ﺭﻗﻌﯽ ۱۶۰ /ﺻﻔﺤﻪ ۵۰۰۰ / ﺗﻮﻣﺎﻥ
È © Å ¥ َﻣﺖ ﺭﻣﺴــﺘﻮﺭﭖ /ﺭﻭﺡﺍ ...ﻭﺍﺻــﻒ /ﺭﻗﻌﯽ ۱۶۰ /ﺻﻔﺤﻪ ۳۸۰۰ /ﺗﻮﻣﺎﻥ
) ³´µ¶ DVDﻣﺠﻤﻮﻋﻪ ﻧﺮﻡﺍﻓﺰﺍﺭﻫﺎﯼ ﻣﻬﻨﺪﺳﯽ ﺗﺎﺳﯿﺴﺎﺕ( ۸۰۰۰ﺗﻮﻣﺎﻥ
) °Ü¹ £¤ ¶¦Æﻭﯾﺮﺍﯾﺶ ﺩﻭﻡ( ﻧﺼﺮﺍ ...ﺣﻘﻮﻗﯽ /ﺭﻗﻌﯽ ۱۷۲ /ﺻﻔﺤﻪ ۵۰۰۰ /ﺗﻮﻣﺎﻥ °¤ Ó§· ﭘــﻞ ﺭﻭﺯﻧﺒــﺮﮒ /ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘــﺎﻥ /ﺭﻗﻌﯽ۲۸۰ / ﺻﻔﺤﻪ ۹۰۰۰ /ﺗﻮﻣﺎﻥ
½ °»í¥ ¨ ¹Ö Ä ®Ù ª ● ACGIH -- INDUSTRIAL VENTILATION, A MANUAL OF RECOMMENDED PRACTICE FOR DESIGN, 26TH EDITION
ﺗﻬﻮﯾــﻪ ﺻﻨﻌﺘﯽ – ﺭﺍﻫﻨﻤﺎﯼ ﮐﺎﺭﺑﺮﺩﯼ ﻃﺮﺍﺣﯽ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﺻﻨﻌﺘﯽ ،ﻭﯾﺮﺍﯾﺶ ﺑﯿﺴﺖ ﻭ ﺷﺸﻢ ● ADVANCED ENERGY DESIGN GUIDE FOR SMALL OFFICE BUILDINGS, ASHRAE PUBLICATION
ﺭﺍﻫﻨﻤﺎﯼ ﭘﯿﺸــﺮﻓﺘﻪ ﻃﺮﺍﺣﯽ ﺗﺎﺳﯿﺴــﺎﺕ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺍﺩﺍﺭﯼ ﺍﺯ ﺩﯾﺪﮔﺎﻩ ﺍﻧﺮﮊﯼ ● ADVANCED ENERGY DESIGN GUIDE FOR SMALL WAREHOUSES AND SELF-STORAGE BUILDINGS, ASHRAE PUBLICATION
ﺭﺍﻫﻨﻤﺎﯼ ﭘﯿﺸــﺮﻓﺘﻪ ﻃﺮﺍﺣﯽ ﺗﺎﺳﯿﺴﺎﺕ ﺍﻧﺒﺎﺭﻫﺎﯼ ﮐﻮﭼﮏ ﺍﺯ ﺩﯾﺪﮔﺎﻩ ﺍﻧﺮﮊﯼ ● ADVANCED VARIABLE AIR VOLUME SYSTEM DESIGN GUIDE
ﺭﺍﻫﻨﻤﺎﯼ ﭘﯿﺸــﺮﻓﺘﻪ ﻃﺮﺍﺣﯽ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺑﺎ ﺣﺠــﻢ ﻫﻮﺍﯼ ﻣﺘﻐﯿﺮ )(VAV ● AIR CONDITIONING SYSTEM DESIGN MANUAL, ASHRAE PUBLICATION
ﺭﺍﻫﻨﻤﺎﯼ ﻃﺮﺍﺣﯽ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ● ASHRAE - ADVANCED ENERGY DESIGN GUIDE FOR HIGHWAY LODGING
ﺭﺍﻫﻨﻤﺎﯼ ﭘﯿﺸﺮﻓﺘﻪ ﻃﺮﺍﺣﯽ ﺗﺎﺳﯿﺴﺎﺕ ﻣﺴﺎﻓﺮﺧﺎﻧﻪﻫﺎ ● ASHRAE - ADVANCED ENERGY DESIGN GUIDE FOR K-12 SCHOOL BUILDINGS ﺭﺍﻫﻨﻤﺎﯼ ﭘﯿﺸــﺮﻓﺘﻪ ﻃﺮﺍﺣﯽ ﺗﺎﺳﯿﺴــﺎﺕ ﻣﺮﺍﮐﺰ ﺁﻣﻮﺯﺷــﯽ K-12ﺍﺯ ﺩﯾﺪﮔﺎﻩ ﺍﻧﺮﮊﯼ ● ASHRAE - ADVANCED ENERGY DESIGN GUIDE FOR SMALL RETAIL BUILDINGS
ﺭﺍﻫﻨﻤﺎﯼ ﭘﯿﺸــﺮﻓﺘﻪ ﻃﺮﺍﺣﯽ ﺗﺎﺳﯿﺴﺎﺕ ﻓﺮﻭﺷــﮕﺎﻩﻫﺎﯼ ﮐﻮﭼﮏ ﺍﺯ ﺩﯾﺪﮔﺎﻩ ﺍﻧﺮﮊﯼ ● ASHRAE HANDBOOK – FUNDAMENTALS 2009 ﻫﻨﺪﺑﻮﮎ ﻣﺒﺎﻧﯽ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺍﺷﺮﯼ 2009 ● ASHRAE HANDBOOK - HVAC SYSTEMS AND EQUIPMENT 2008 ﻫﻨﺪﺑﻮﮎ ﺗﺠﻬﯿﺰﺍﺕ ﻭ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺍﺷﺮﯼ 2008 ● ASHRAE HANDBOOK – REFRIGERATION 2006 ﻫﻨﺪﺑﻮﮎ ﻣﺒﺎﻧﯽ ﺳﺮﻣﺎﯾﺶ ﺍﺷﺮﯼ 2006 ● ASHRAE HANDBOOK HVAC APPLICATION 2007 ﻫﻨﺪﺑﻮﮎ ﮐﺎﺭﺑﺮﺩﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺍﺷﺮﯼ 2007 ● ASHRAE POCKET GUIDE
ﺭﺍﻫﻨﻤﺎﯼ ﺟﯿﺒﯽ ﺍﺷﺮﯼ ● ASHRAE TERMINOLOGY OF HVAC & R
ﻓﺮﻫﻨﮓ ﺗﺎﺳﯿﺴﺎﺕ ﺍﺷﺮﯼ ● BLUEPRINTS AND PLANS FOR HVAC
ﻧﻘﺸﻪﮐﺸﯽ ﺗﺎﺳﯿﺴﺎﺕ ● BOILER OPERATION ENGINEERING, QUESTIONS AND ANSWERS
ﺭﻭﺵﻫﺎﯼ ﻣﻬﻨﺪﺳــﯽ ﺑﺮﺍﯼ ﺭﺍﻫﺒﺮﯼ ﺩﯾﮓﻫﺎ -ﭘﺮﺳﺶ ﻭ ﭘﺎﺳﺦﻫﺎﯾﯽ ﺩﺭﺑﺎﺭﻩ ﺩﯾﮓﻫﺎ ● BOILER OPERATOR'S HANDBOOK ﻫﻨﺪﺑﻮﮎ ﺭﺍﻫﺒﺮﯼ ﺩﯾﮓﻫﺎ ● BUILDING SERVICES HANDBOOK
ﻫﻨﺪﺑﻮﮎ ﺗﺎﺳﯿﺴﺎﺕ ﺳﺎﺧﺘﻤﺎﻥ ● CARRIER HVAC INSTALLATION PROCEDURES HANDBOOK ﻫﻨﺪﺑﻮﮎ ﺭﻭﺵﻫﺎﯼ ﻧﺼﺐ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ CARRIER ● CARRIER HVAC MAINTENANCE PROCEDURES HANDBOOK
ﻫﻨﺪﺑــﻮﮎ ﺗﻌﻤﯿــﺮ ﻭ ﻧﮕﻬــﺪﺍﺭﯼ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾــﻪ ﻣﻄﺒــﻮﻉ CARRIER ● CARRIER HVAC SERVICING PROCEDURES, 1995
ﻫﻨﺪﺑــﻮﮎ ﺭﻭﺵﻫــﺎﯼ ﺳــﺮﻭﯾﺲ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾــﻪ ﻣﻄﺒــﻮﻉ CARRIER ● CARRIER SYSTEM DESIGN MANUAL 12 VOLUME SET ﺭﺍﻫﻨﻤــﺎﯼ ﻃﺮﺍﺣــﯽ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒــﻮﻉ ،CARRIER
ﻣﺠﻤﻮﻋﻪ ﺩﻭﺍﺯﺩﻩ ﺟﻠﺪﯼ ● CARRIER SYSTEM DESIGN MANUAL 3 VOLUME SET ﺭﺍﻫﻨﻤــﺎﯼ ﻃﺮﺍﺣــﯽ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒــﻮﻉ ،CARRIER
ﻣﺠﻤﻮﻋﻪ ﺳﻪ ﺟﻠﺪﯼ ● DESIGN ESSENTIALS FOR REFRIGERATED )STORAGE FACILITIES (ASHRAE
ﻣﺒﺎﻧﯽ ﻃﺮﺍﺣﯽ ﺳﺮﺩﺧﺎﻧﻪ ﺍﺷﺮﯼ ● DESIGN MANUAL FOR HEATING, VENTILATION, PLUMBING AND AIR )CONDITIONING SYSTEMS (4 EDITION
ﺭﺍﻫﻨﻤــﺎﯼ ﻃﺮﺍﺣﯽ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﮔﺮﻣﺎﯾﺶ ،ﺗﻬﻮﯾﻪ ،ﻟﻮﻟﻪﮐﺸــﯽ ﻭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ،ﻭﯾﺮﺍﯾﺶ ﭼﻬﺎﺭﻡ
● DOMESTIC CENTRAL HEATING WIRING SYSTEMS AND CONTROLS
● TRANE AIR CONDITIONING MANUAL ﻫﻨﺪﺑﻮﮎ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ TRANE
● DUCTULATOR - DUCT SIZING CALCULATOR, TRANE
● TRANE RECIPROCATING REFRIGERATION MANUAL ﻫﻨﺪﺑﻮﮎ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺳﺮﻣﺎﯾﺶ ﺗﺮﺍﮐﻤﯽ TRANE
ﺭﺍﻫﻨﻤﺎﯼ ﺳﯿﻢﮐﺸﯽ ﻭ ﮐﻨﺘﺮﻝ ﻣﻮﺗﻮﺭﺧﺎﻧﻪﻫﺎﯼ ﺧﺎﻧﮕﯽ
– DUCTULATORﺭﺍﻫﻨﻤﺎﯼ ﻣﺤﺎﺳﺒﻪ ﺍﻧﺪﺍﺯﻩ ﮐﺎﻧﺎﻝ & ● ELECTROMECHANICAL DEVICES COMPONENTS ILLUSTRATED SOURCEBOOK ﻣﺮﺟﻊ ﺗﺼﻮﯾﺮﯼ ﺗﺠﻬﯿﺰﺍﺕ ﻭ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺍﻟﮑﺘﺮﻭﻣﮑﺎﻧﯿﮑﯽ ● ENERGY MANAGEMENT AND CONSERVATION HANDBOOK
ﻫﻨﺪﺑﻮﮎ ﺻﺮﻓﻪﺟﻮﯾﯽ ﻭ ﻣﺪﯾﺮﯾﺖ ﺍﻧﺮﮊﯼ
● VALVE HANDBOOK
ﻫﻨﺪﺑﻮﮎ ﺷﯿﺮﺁﻻﺕ ● VALVE SELECTION HANDBOOK ● VENTILATION SYSTEMS - DESIGN AND PERFORMANCE
ﻫﻨﺪﺑﻮﮎ ﺍﻧﺘﺨﺎﺏ ﺷﯿﺮﺁﻻﺕ
● ENGINEERING COOKBOOK
ﻫﻨﺪﺑﻮﮎ ﮐﺎﺭﺑﺮﺩﯼ ﻣﻬﻨﺪﺳﯿﻦ ● ENVIRONMENTAL CONTROL SYSTEMS
ﺳﯿﺴﺘﻢﻫﺎﯼ ﮐﻨﺘﺮﻝ ﻣﺤﯿﻄﯽ
¶Ä· ©Í
● FAN HANDBOOK (SELECTION, )APPLICATION AND DESIGN
¶· ©Í¶ ¨ ÕÖ § ÀÕ ÕÖ Ä· ©Í ﻣﮕﯽ ﺗﻮﯼ /ﻣﯿﻨﺎ ﻣﻬﺪﻟﻮ /ﺭﺣﻠﯽ ۱۸۴ /ﺻﻔﺤﻪ ۱۳۵۰۰ /ﺗﻮﻣﺎﻥ
● FUNDAMENTALS OF HVAC SYSTEMS, ASHRAE PUBLICATION
«´½°¶ · ½ ÀÕ¢Û¼ ®¨ ©ª ﺍﺩﻭﺍﺭﺩ ﺁﻟﻦ /ﺍﺣﺴﺎﻥﺍ ...ﺳﺒﻂﺍﻟﺸﯿﺦ /ﻭﺯﯾﺮﯼ ۳۲۸ /ﺻﻔﺤﻪ / ۷۵۰۰ﺗﻮﻣﺎﻥ
ﻫﻨﺪﺑﻮﮎ ﻓﻦﻫﺎ -ﺍﻧﺘﺨﺎﺏ ،ﮐﺎﺭﺑﺮﺩ ﻭ ﻃﺮﺍﺣﯽ
ﻣﺒﺎﻧﯽ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ● GUIDE TO ENERGY MANAGEMENT
ﺭﺍﻫﻨﻤﺎﯼ ﻣﺪﯾﺮﯾﺖ ﺍﻧﺮﮊﯼ ● HEATING AND AIR CONDITIONING OF BUILDINGS
¨¥¦¤¥ ° ´µ¶ · Ò® Ó ¦ Ƹ ¹ ﻣﻬﺪﯼ ﺑﻬﺎﺩﺭﯼﻧﮋﺍﺩ -ﻋﻠﯿﺮﺿﺎ ﺩﻫﻘﺎﻧﯽ /ﻭﺯﯾﺮﯼ ۴۱۶ /ﺻﻔﺤﻪ / ۱۲۰۰۰ﺗﻮﻣﺎﻥ
ﮔﺮﻣﺎﯾﺶ ﻭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺩﺭ ﺳﺎﺧﺘﻤﺎﻥﻫﺎ ● HEATING BOILER OPERATOR'S MANUAL
ﺭﺍﻫﻨﻤﺎﯼ ﺭﺍﻫﺒﺮﯼ ﺩﯾﮓﻫﺎﯼ ﮔﺮﻣﺎﯾﺸﯽ ● HEATING SYSTEMS, PLANT AND CONTROL
Ä· ©Í¶ ¹ ¤¦æ ﺩﯾﻮﯾﺪ ﺁﯾﺴﻦ /ﻣﻬﺪﯼ ﻣﻬﺪﻟﻮ /ﺟﯿﺒﯽ ۸۴ /ﺻﻔﺤﻪ ﺑﻪ ﻫﻤﺮﺍﻩ ۳۵ﮐﻠﯿﺸﻪ ۳۰۰۰۰ /ﺗﻮﻣﺎﻥ
ﺗﺠﻬﯿﺰﺍﺕ ﻭ ﺭﻭﺵﻫﺎﯼ ﮐﻨﺘﺮﻝ ﺳﯿﺴﺘﻢﻫﺎﯼ ﮔﺮﻣﺎﯾﺸﯽ ● HVAC DESIGN GUIDE FOR TALL )COMMERCIAL BUILDINGS (ASHRAE
ﺭﺍﻫﻨﻤﺎﯼ ﻃﺮﺍﺣﯽ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺑﺮﺍﯼ ﺳﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﺑﻠﻨﺪﻣﺮﺗﺒﻪ ﺗﺠﺎﺭﯼ ● HVAC DESIGN MANUAL FOR HOSPITALS )AND CLINICS (ASHRAE
ﺭﺍﻫﻨﻤﺎﯼ ﻃﺮﺍﺣﯽ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺑﺮﺍﯼ ﺑﯿﻤﺎﺭﺳﺘﺎﻥﻫﺎ ﻭ ﮐﻠﯿﻨﯿﮏﻫﺎ ● HVAC EQUATIONS, DATA AND RULES OF THUMB - SECOND EDITION ﻣﻌﺎﺩﻻﺕ ،ﺩﺍﺩﻩﻫﺎ ﻭ ﺭﻭﺍﺑﻂ ﺳﺮﺍﻧﮕﺸﺘﯽ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ – ﻭﯾﺮﺍﯾﺶ ﺩﻭﻡ ● HVAC HANDBOOK
ﻫﻨﺪﺑﻮﮎ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ● HVAC INSTALLATION PROCEDURES HANDBOOK
ﻫﻨﺪﺑﻮﮎ ﺭﻭﺵﻫﺎﯼ ﻧﺼﺐ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ● HVAC MAINTENANCE AND OPERATIONS HANDBOOK
ﻫﻨﺪﺑﻮﮎ ﺭﺍﻫﺒﺮﯼ ﻭ ﺗﻌﻤﯿﺮ ﻭ ﻧﮕﻬﺪﺍﺭﯼ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ
¯¦Ä· ©Í¶ Ö¥ ¦ ¥ ﻟﻮﮐﻮﺭﺑﻮﺯﯾﻪ /ﺩﯾﻨﺎ ﺩﻫﻘﺎﻥ /ﻭﺯﯾﺮﯼ ۲۵۶ /ﺻﻔﺤﻪ ۶۰۰۰ /ﺗﻮﻣﺎﻥ ¯¦®¬ Ä· ©Í¶ Ä¦é¹ ﻓﺮﺍﻧﺴﯿﺲ ﺩﯼ .ﮐﯽ .ﭼﯿﻨﮓ /ﻣﺤﻤﺪﺭﺿﺎ ﺍﻓﻀﻠﯽ /ﺭﺣﻠﯽ/ ۳۵۲ﺻﻔﺤﻪ ۹۸۰۰ /ﺗﻮﻣﺎﻥ ¶ÇöëÕ Ú ë ¯ Ú¡¦ë¯ :Ä· ë©Í ﻓﺮﺍﻧﺴﯿﺲ ﺩﯼ .ﮐﯽ .ﭼﯿﻨﮓ /ﻣﺤﻤﺪﺭﺿﺎ ﺍﻓﻀﻠﯽ /ﺭﺣﻠﯽ/ ۴۷۲ﺻﻔﺤﻪ ۹۵۰۰ /ﺗﻮﻣﺎﻥ Ä· ©Í¶ ·¸ ßÖ ﻓﺮﺍﻧﺴﯿﺲ ﺩﯼ .ﮐﯽ .ﭼﯿﻨﮓ /ﻣﺤﻤﺪﺭﺿﺎ ﺍﻓﻀﻠﯽ /ﺭﺣﻠﯽ/ ۴۳۲ﺻﻔﺤﻪ ۹۸۰۰ /ﺗﻮﻣﺎﻥ «Ä· ©Í¶ ·¸ á ﻓﺮﺍﻧﺴﯿﺲ ﺩﯼ .ﮐﯽ .ﭼﯿﻨﮓ /ﻣﺤﻤﺪﺭﺿﺎ ﺍﻓﻀﻠﯽ /ﺭﺣﻠﯽ/ ۴۹۶ﺻﻔﺤﻪ ۱۵۰۰۰ /ﺗﻮﻣﺎﻥ
● HVAC PUMP HANDBOOK
ÀÕ îЫ Ä´¤¥¦¯ Ç ¦ ﻓﺮﺍﻧﺴﯿﺲ ﺩﯼ .ﮐﯽ .ﭼﯿﻨﮓ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﺣﻠﯽ۲۰۸ / ﺻﻔﺤﻪ ۸۰۰۰ /ﺗﻮﻣﺎﻥ
● HVAC TROUBLESHOOTING GUIDE
¶¥¦²¥ á÷ Õ ½ Ö¥ ÄÖ ÀË¢ç ﮔـﺮﺍﻧﺖ ﺩﺍﺑﻠﯿـﻮ ِﺭﯾﺪ /ﺳــﯿﺪﻩ ﻣﺮﯾﻢ ﺳﯿﺎﺩﺗﯽ /ﺭﺣﻠﯽ۱۹۲ / ﺻﻔﺤﻪ ۱۰۰۰۰ /ﺗﻮﻣﺎﻥ
ﻫﻨﺪﺑﻮﮎ ﭘﻤﭗﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ● HVAC SIMPLIFIED
ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ﺑﻪ ﺯﺑﺎﻥ ﺳﺎﺩﻩ ﺭﺍﻫﻨﻤﺎﯼ ﻋﯿﺐﯾﺎﺑﯽ ﺳﯿﺴﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ ● PIPELINE AND RISERS
ﺭﺍﯾﺰﺭﻫﺎ ﻭ ﺧﻄﻮﻁ ﻟﻮﻟﻪ ● PIPING AND PIPELINES ASSESSMENT GUIDE
ﺭﺍﻫﻨﻤﺎﯼ ﺍﺭﺯﯾﺎﺑﯽ ﺧﻄﻮﻁ ﻟﻮﻟﻪ ﻭ ﺷﺒﮑﻪﻫﺎﯼ ﻟﻮﻟﻪﮐﺸﯽ
¨¥¦¤¥ Ä· ©Í¶ ¸ ©Õ Ú¦ Ƹ ¹ ﻣﻬﻨﺎﺯ ﻣﺤﻤﻮﺩﯼ /ﺧﺸﺘﯽ ۲۷۶ /ﺻﻔﺤﻪ ۸۰۰۰ /ﺗﻮﻣﺎﻥ
● PIPING CALCULATIONS MANUAL
ﺭﺍﻫﻨﻤﺎﯼ ﻣﺤﺎﺳﺒﺎﺕ ﻟﻮﻟﻪﮐﺸﯽ ● PIPING SYSTEMS & PIPELINE ASME CODE SIMPLIFIED ﺭﺍﻫﻨﻤﺎﯼ ﺳﺎﺩﻩ ﺳﯿﺴﺘﻢﻫﺎﯼ ﻟﻮﻟﻪﮐﺸﯽ ﻭ ﺧﻄﻮﻁ ﻟﻮﻟﻪ ASME ● PRACTICAL CENTRIFUGAL PUMPSDESIGN, OPERATION AND MAINTENANCE
ﺭﺍﻫﻨﻤــﺎﯼ ﮐﺎﺭﺑــﺮﺩﯼ ﻃﺮﺍﺣــﯽ ،ﺭﺍﻫﺒــﺮﯼ ﻭ ﺗﻌﻤﯿــﺮ ﻭ ﻧﮕﻬﺪﺍﺭﯼ ﭘﻤﭗﻫﺎﯼ ﮔﺮﯾﺰ ﺍﺯ ﻣﺮﮐﺰ ● REFRIGERATION AND AIR-CONDITIONING, FOURTH EDITION
ﺳﺮﻣﺎﯾﺶ ﻭ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ -ﻭﯾﺮﺍﯾﺶ ﭼﻬﺎﺭﻡ ● REFRIGERATION, A RESIDENTIAL AND LIGHT COMMERCIAL TEXT & LAB BOOK
ﻣﺒﺎﻧــﯽ ﻭ ﺭﻭﺵﻫــﺎﯼ ﮐﺎﺭﺑﺮﺩﯼ ﺳــﺮﻣﺎﯾﺶ ﺑﺮﺍﯼ ﺳــﺎﺧﺘﻤﺎﻥﻫﺎﯼ ﻣﺴﮑﻮﻧﯽ ﻭ ﺗﺠﺎﺭﯼ ● SMACNA -- HVAC SYSTEMS - DUCT DESIGN, 4TH EDITION ﻃﺮﺍﺣﯽ ﮐﺎﻧﺎﻝ ﺑﺮﺍﯼ ﺳﯿﺴــﺘﻢﻫﺎﯼ ﺗﻬﻮﯾﻪ ﻣﻄﺒﻮﻉ،SMACNA ، ﻭﯾﺮﺍﯾﺶ ﭼﻬﺎﺭﻡ
(¡ Æ À¹ ¡ Æ) °»«¥¸ Ä· ©Í¶ â Ò ¥ ﻧﻮﺭﯾﻮﺷــﯽ ﻫﺎﺳــﻪﮔﺎﻭﺍ /ﮐﻮﺭﺵ ﻣﺤﻤــﻮﺩﯼ ﺩﻩﺩﻩ ﺑﯿﮕﻠﻮ، ﺁﯾﻠﯿﻦ ﺍﻧﺴــﺎﻥ ﮔﻠﭽﻬﺮﻩ ﺭﺿﺎﺋــﯽﺭﺍﺩ /ﻭﺯﯾﺮﯼ ۱۶۰ /ﺻﻔﺤﻪ ۹۰۰۰ /ﺗﻮﻣﺎﻥ ¸¥´¶ ¹ â Ò ¥ ﺗﻮﻣﺎﺱ ﻭﺍﻧﮓ /ﺛﻤﺮ ﺗﺮﺍﺑﯽ ﮐﺮﻣﺎﻧﺸــﺎﻩ /ﺭﺣﻠﯽ ۱۲۰ /ﺻﻔﺤﻪ ۴۳۰۰ /ﺗﻮﻣﺎﻥ Ã¤Ô ¶ ¹ â Ò ¥ ﺗﻮﻣﺎﺱ ﻭﺍﻧﮓ /ﺛﻤﺮ ﺗﺮﺍﺑﯽ ﮐﺮﻣﺎﻧﺸــﺎﻩ /ﺭﺣﻠﯽ ﺑﺰﺭﮒ ۱۰۴ / ﺻﻔﺤﻪ ۷۰۰۰ /ﺗﻮﻣﺎﻥ ¬Õ· § â Ò ¥ ﭘﻞ ﺗﺎﮔﺎﺭﺕ /ﺛﻤﺮ ﺗﺮﺍﺑﯽ ﮐﺮﻣﺎﻧﺸــﺎﻩ /ﺧﺸﺘﯽ ۱۰۸ /ﺻﻔﺤﻪ ۷۵۰۰ /ﺗﻮﻣﺎﻥ ×(Þ Ø¤ § · ±Õ¥Ù× Ú î) ¨¥¦¤¥ Я ·¸ Ù ﻋﻠﯿﺮﺿﺎ ﺩﻫﻘﺎﻧﯽ /ﺭﻗﻌﯽ ۱۲۰ /ﺻﻔﺤﻪ ۴۵۰۰ /ﺗﻮﻣﺎﻥ
Ä· ©Í¶ § ßÖ ﺁﻧﮕــﻮﺱ ﺟﯽ .ﻣﮏ ﺩﺍﻧﻠﺪ /ﻋﻠﯽ ﻣﺴــﻌﻮﺩﯼﻧﯿﺎ /ﺭﻗﻌﯽ / ۲۴۸ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ ¶¦Ö §á« °± ² ̲ ﭘــﻞ ﺭﻭﺯﻧﺒﺮﮒ /ﺭﺍﻣﯿــﻦ ﺗﺎﺑﺎﻥ /ﺟﯿﺒــﯽ ۴۱۶ /ﺻﻔﺤﻪ / ۴۰۰۰ﺗﻮﻣﺎﻥ ¶¦Ä· ©Í¶ °± ² ̲ ﺷــﺎﺭﻟﻮﺕ ﺑﺎﺩﻥ ﭘﺎﻭﻝ /ﺣﻤﯿﺪﺭﺿــﺎ ﺍﯾﺰﺩﯼ /ﺭﻗﻌﯽ ۲۸۸ / ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ ר µ² Ä· ©Í¶ ¹ °¤ Ó ﺍﻣﯿﻠــﯽ ُﮐﻞ /ﮐﻮﺭﺵ ﻣﺤﻤﻮﺩﯼ ﺩﻩﺩﻩ ﺑﯿﮕﻠﻮ ،ﺭﺿﺎ ﺑﺼﯿﺮﯼ ﻣﮋﺩﻫــﯽ ،ﺭﻭﺯﺑــﻪ ﺍﺣﻤﺪﯼ ﻧﮋﺍﺩ /ﻭﺯﯾــﺮﯼ ۳۵۲ /ﺻﻔﺤﻪ/ ۸۰۰۰ﺗﻮﻣﺎﻥ ¨ ©ª« °¤¥¦²¥ ÒÕ ﻣﯿﺸﻞ ﮐﯿﺴﯽ ،ﺭﺩﻭﻭﺩ ﮐﺎﺭﺩﻥ ﻭ ﺩﺍﮔﻼﺱ ﻫﻨﺴﻦ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۹۶ /ﺻﻔﺤﻪ ۲۸۰۰ /ﺗﻮﻣﺎﻥ °©¤¥ °¤¥¦²¥ ÒÕ ﻣﯿﺸﻞ ﮐﯿﺴﯽ ،ﺭﺩﻭﻭﺩ ﮐﺎﺭﺩﻥ ﻭ ﺩﺍﮔﻼﺱ ﻫﻨﺴﻦ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۱۲۸ /ﺻﻔﺤﻪ ۳۲۰۰ /ﺗﻮﻣﺎﻥ Ä· ©Í¶ Ä ®¢ÛÝ¥ ﺭﺍﺟﺮ ﺍﭺ .ﮐﻼﺭﮎ ﻭ ﻣﺎﯾﮑﻞ ﭘﺎﻭﺯ /ﺛﻤـﺮ ﺗﺮﺍﺑﯽ ﮐﺮﻣﺎﻧﺸــﺎﻩ / ﺭﺣﻠﯽ ۳۲۴ /ﺻﻔﺤﻪ ۹۰۰۰ /ﺗﻮﻣﺎﻥ Ä· ©Í¶ °Ï¥¦Ë ﭘﺘﺮ ﻓﺎﺳﺖ /ﻣﺤﻤﺪﺭﺿﺎ ﺷــﺎﻫﯽ /ﺭﻗﻌﯽ ۱۷۶ /ﺻﻔﺤﻪ ۴۰۰۰ / ﺗﻮﻣﺎﻥ ½¥´í Þ¦ª ﻣﺎﺭﺗﯿﻦ ﻫﺮﺷﻮﺭﻥ /ﻣﺠﺘﺒﯽ ﺧﺎﻥﺯﺍﺩﻩ /ﺭﻗﻌﯽ ۱۸۴ /ﺻﻔﺤﻪ ۵۰۰۰ /ﺗﻮﻣﺎﻥ ·§ßÖ ° ± ç¶ ¹¥ ﺍﯾﻠﯿﺎ ﻣﯿﮑﻠﺴــﻮﻥ /ﺑﺎﻣﺪﺍﺩ ﻓﺘﻮﺣﯽ /ﺭﻗﻌﯽ ۲۰۰ /ﺻﻔﺤﻪ ۳۴۰۰ / ﺗﻮﻣﺎﻥ °Ø¤· Ä· ©Í¶ ¦í Ñ ° ÓÀÕ¢Æ ﺟﺎﻥ ﺗﺌﻮﺩﻭﺭ ﻫﺎﻧﻤﻦ /ﺳــﯿﺪﻩ ﻣﺮﯾﻢ ﺳﯿﺎﺩﺗﯽ /ﺭﺣﻠﯽ۱۶۰ / ﺻﻔﺤﻪ ۶۴۰۰ /ﺗﻮﻣﺎﻥ ¨ ©ª« ·¸ ÀÜ Ó ﺁﻟﯿﺴﻮﻥ ﮔﺮﺍﻧﺖ ،ﺁﻥ ﺁﻟﺪﺭﺳﻮﻥ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ۱۲۸ / ﺻﻔﺤﻪ ۵۰۰۰ /ﺗﻮﻣﺎﻥ ¸·® à ¶¢ ¥ Ä ﺁﻟﯿﺴــﻮﻥ ﮔﺮﺍﻧﺖ ،ﭘﺎﻝ ﻫﺎﯾﻤﻦ /ﻣﺤﻤﺪﺗﻘﯽ ﺣﺴــﻦﺯﺍﺩﻩ / ﺭﻗﻌﯽ ۵۶ /ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ ½ ÄÖ ﺁﻟﯿﺴــﻮﻥ ﮔﺮﺍﻧﺖ ،ﺁﻥ ﺁﻟﺪﺭﺳﻮﻥ /ﻧﯿﺮﻩ ﺷﻤﺸﯿﺮﯼ /ﺭﻗﻌﯽ / ۱۰۴ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ × ä Ý¢»Í¶ ·¢ Õ ﺁﻟﯿﺴﻮﻥ ﮔﺮﺍﻧﺖ ،ﭘﺎﻝ ﻫﺎﯾﻤﻦ /ﻣﺠﺘﺒﯽ ﺧﺎﻥﺯﺍﺩﻩ /ﺭﻗﻌﯽ / ۶۴ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ Ä· ©Í¶ ·¸ õ×Å¥¦¤ ﺁﻟﯿﺴﻮﻥ ﮔﺮﺍﻧﺖ ،ﭘﺎﻝ ﻫﺎﯾﻤﻦ /ﺳﺎﺭﺍ ﮔﻠﭽﯿﻦ /ﺭﻗﻌﯽ ۶۴ / ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ ·°»«¥¸ °Ï¥¦Ë ·¸ ¬Õ ﺟﺎﻧﺎﺗﺎﻥ ﭘﻮﺭﻩ /ﻓﺮﺯﺍﻧﻪ ﭘﺎﯾﺪﺍﺭ ﺩﺍﺭﯾﺎﻥ /ﺭﻗﻌﯽ ۱۴۴ /ﺻﻔﺤﻪ ۵۰۰۰ /ﺗﻮﻣﺎﻥ ÀÕ «È÷Ó× °Ï¥¦Ë ﺷــﺎﺭﻟﻮﺕ ﺑﺎﺩﻥ ﭘﺎﻭﻝ /ﻣﺤﻤﺪﺭﺿﺎ ﺷــﺎﻫﯽ /ﺭﻗﻌﯽ ۲۰۰ / ﺻﻔﺤﻪ ۳۵۰۰ /ﺗﻮﻣﺎﻥ ¶ÄÖ ÀË¢ç ﻫﻠــﻦ ﺩﺍﻻﺱ ﻭ ﻣﯿﺘﻞ ﻟﯿﺘﻞﻭﻭﺩ /ﺛﻤﺮ ﺗﺮﺍﺑﯽ ﮐﺮﻣﺎﻧﺸــﺎﻩ / ﺭﻗﻌﯽ ۱۳۶ /ﺻﻔﺤﻪ ۳۵۰۰ /ﺗﻮﻣﺎﻥ ¶Î¤¦Ï § Ä· ©Í ﮐﻮﺭﮐﯽ ﺑﯿﻨﮕﻠﯽ /ﺣﺴــﻦ ﻣﺤﻤﺪﯼ /ﺭﻗﻌﯽ ۱۵۲ /ﺻﻔﺤﻪ ۴۵۰۰ /ﺗﻮﻣﺎﻥ
׽à ª ¢ ﮐﻮﺭﮐﯽ ﺑﯿﻨﮕﻠﯽ /ﻣﺤﻤﺪﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ /ﺭﻗﻌﯽ ۱۳۶ /ﺻﻔﺤﻪ ۳۲۰۰ /ﺗﻮﻣﺎﻥ ×ÙÐ ¯ § Ù ﮐﻮﺭﮐﯽ ﺑﯿﻨﮕﻠﯽ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۱۷۶ /ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ ¶àª® °Ï¥¦Ë °Õ ± ﻓﺮﺩ ﻻﺳــﻮﻥ ﻭ ﺟﺎﻥ ﻻﺳــﻮﻥ /ﻓﺮﺯﺍﻧﻪ ﭘﺎﯾﺪﺍﺭ ﺩﺍﺭﯾﺎﻥ /ﺭﻗﻌﯽ / ۱۲۰ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ ¨¥· ©Í¶ Ä¥¦¹ ¾¢±¿¶ À¤¢µ ﮐﻮﺭﮐﯽ ﺑﯿﻨﮕﻠﯽ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۱۸۴ /ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ ¨¥· ©Í¶ Ä¥¦¹ Ŧ¹ ﮐﻮﺭﮐﯽ ﺑﯿﻨﮕﻠﯽ /ﺭﺍﻣﯿﻦ ﺗﺎﺑﺎﻥ /ﺭﻗﻌﯽ ۳۲۰ /ﺻﻔﺤﻪ ۸۰۰۰ /ﺗﻮﻣﺎﻥ «°ªÍí Ä ®¨ ©ª ﺍﺭﻧﺴــﺖ ﻧﻮﯾﻔﺮﺕ ﻭ ﺟﻮﻟﯿﺎﻥ ﺩﺭﻭﺭﯼ /ﺳــﯿﺪﻩ ﻣﺮﯾﻢ ﺳﯿﺎﺩﺗﯽ / ﺭﻗﻌﯽ ۱۷۶ /ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ ¨ һ ﺁﻟﻦ ﻭﺳــﯿﻠﻮﯾﺎ ﺑﻼﻧﮏ /ﺣﺴــﯿﻦ ﺧﺪﺍﻭﺭﺩﯾــﺎﻥ /ﺭﻗﻌﯽ۳۳۶ / ﺻﻔﺤﻪ ۷۰۰۰ /ﺗﻮﻣﺎﻥ
°©¤¥ § °ª ¶¥ Ú°Ë ± ·¥ Ä ®Çª ﺳــﯿﻮﻝ /ﺍﻓﺮﻭﺯ ﻋﻨﺎﯾﺘﯽ /ﺭﻗﻌﯽ۱۴۰ / ﮐﻮﺭﮐﯽ ﺑﯿﻨﮕﻠﯽ ،ﻭﯾﻠﯿﺎﻡ ِ ﺻﻔﺤﻪ ۴۰۰۰ /ﺗﻮﻣﺎﻥ
¸® (¦ÍÓ ÀÑ¢©É¶) ´®¸°¶ ¤·¸ Ä¢¹ ÇÕ ﻣﺤﻤﺪﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ /ﺭﻗﻌﯽ ۱۰۴ /ﺻﻔﺤﻪ ۳۰۰۰ /ﺗﻮﻣﺎﻥ (¦ÍÓ ÀÑ¢©É¶) Ʀ¹ Ö¥ ¦¹ ·ºÆ ﻣﺤﻤﺪﺣﺴﯿﻦ ﺩﻫﻘﺎﻥ /ﺭﻗﻌﯽ ۷۲ /ﺻﻔﺤﻪ ۱۵۰۰ /ﺗﻮﻣﺎﻥ
°¶¢©Ñ
(¦ÍÓ ÀÑ¢©É¶) ÀÕ¥·¸ ¶ Ä ®ÀÕ ÊÓ Ñ ÚÀÕ¥·´Â Ä ®°¤õõ ﺭﺿﺎ ﺧﺎﻭﺭﺳﻨﮕﺮﯼ /ﺭﻗﻌﯽ ۸۸ /ﺻﻔﺤﻪ ۳۳۰۰ /ﺗﻮﻣﺎﻥ
(°Ñ ¹· áæ® § ¸ ªæ® À æ ) È ¤  ·¸ · µ¹ ﻣﺤﻤﺪﻋﻠﯽ ﺍﺳﻼﻣﯽ ﻧﺪﻭﺷﻦ /ﺟﯿﺒﯽ ۱۶۸ /ﺻﻔﺤﻪ ۹۰۰۰ /ﺗﻮﻣﺎﻥ
¶¨¥´ÕÖ¦¯ °±»ËßÖ· ±
áÓ¢Õ¦ °¹Ä ®ÀªÓ¢Õ ﻣﺤﻤﺪﻋﻠﯽ ﺍﺳﻼﻣﯽ ﻧﺪﻭﺷﻦ /ﻭﺯﯾﺮﯼ ۳۳۶ /ﺻﻔﺤﻪ ۶۵۰۰ /ﺗﻮﻣﺎﻥ
ﺭﺩﻟــﻒ ﺩﺭﯾﮑــﺮﺯ /ﻓﺮﺯﺍﻧﻪ ﭘﺎﯾﺪﺍﺭ ﺩﺍﺭﯾﺎﻥ /ﺭﻗﻌــﯽ ۲۵۶ /ﺻﻔﺤﻪ / ۳۳۰۰ﺗﻮﻣﺎﻥ
ÎÜÑ Ä¢¹ § Ö¥¦ Ó « Ä´Í ﺷﯿﺮﯾﻦ ﺑﯿﺎﻧﯽ /ﻭﺯﯾﺮﯼ ۲۸۸ /ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ
¦ ¨¥¦¤¥ áæÕ áÍí ÀÝ ´éÒ¤
ÅЫ¥ ° ´µ¶ § ° ´µ¶ ÅЫ¥ ﻣﻬﺪﯼ ﺑﻬﺎﺩﺭﯼﻧﮋﺍﺩ /ﺭﻗﻌﯽ ۲۶۴ /ﺻﻔﺤﻪ ۵۵۰۰ /ﺗﻮﻣﺎﻥ
ﺳــﯿﺪ ﻣﺤﻤﺪ ﺯﻣﺎﻥ ﺩﺭﯾﺎﺑﺎﺭﯼ ﻭﺷﺘﺎﻧﯽ ﻣﺮﺗﻀﯽ ﺑﮑﯽ ﺣﺴﮑﻮﯾﯽ / ﺭﻗﻌﯽ ۲۸۰ /ﺻﻔﺤﻪ ۴۵۰۰ /ﺗﻮﻣﺎﻥ Ǫ¤· Ä·¢ ﻋﻠﯿﺮﺿــﺎ ﭘﯿﺮﻭﺯﻧﯿﺎ -ﻓﻬﯿﻤﻪ ﺷــﻬﺮﺍﺑﯽ /ﺭﻗﻌــﯽ ۱۰۶ /ﺻﻔﺤﻪ / ۵۰۰۰ﺗﻮﻣﺎﻥ
°Æ´ÕÖ § ĸ Ó ﻣﻬﺪﯼ ﺑﻬﺎﺩﺭﯼﻧﮋﺍﺩ /ﺭﻗﻌﯽ ۱۹۲ /ﺻﻔﺤﻪ ۳۵۰۰ /ﺗﻮﻣﺎﻥ
ﺟﻬــﺖ ﺩﺭﯾﺎﻓــﺖ ﮐﺘﺎﺏﻫــﺎ ﻭ ﻧﺸــﺮﯾﺎﺕ ﻣﻮﺭﺩ ﺩﺭﺧﻮﺍﺳــﺖ ﮐﺎﻓﯽ ﺍﺳــﺖ ﻣﺒﻠﻎ ﻣــﻮﺭﺩ ﻧﻈﺮ ﺭﺍ ﺑــﻪ ﯾﮑﯽ ﺍﺯ ﺣﺴــﺎﺏﻫﺎﯼ »ﺟــﺎﻡ ۵۷۶۳۰۱۴ﻧﺰﺩ ﺑﺎﻧــﮏ ﻣﻠﺖ«، »ﺟﺎﺭﯼ ﺳــﯿﺒﺎ ۰۱۰۰۲۶۹۹۶۱۰۰۹ﻧﺰﺩ ﺑﺎﻧﮏ ﻣﻠﯽ«» ،ﺳــﭙﻬﺮ ۰۳۱۰۸۰۴۹۷۰۰۰۳ﻧﺰﺩ ﺑﺎﻧﮏ ﺻﺎﺩﺭﺍﺕ« ﻭ ﯾﺎ »ﺟﺎﺭﯼ ﻫﻤﺮﺍﻩ ﺭﻓﺎﻩ ۲۴۸۵۷۴۶ﻧﺰﺩ ﺑﺎﻧﮏ ﺭﻓﺎﻩ« ﺑﻪ ﻧﺎﻡ ﻣﺤﻤﺪﺣﺴــﯿﻦ ﺩﻫﻘﺎﻥ ،ﻭﺍﺭﯾﺰ ﮐﺮﺩﻩ ،ﻓﯿﺶ ﺑﺎﻧﮑﯽ ﻭ ﻓﺮﻡ ﺗﮑﻤﯿﻞﺷــﺪﻩ ﺯﯾﺮ ﺭﺍ ﺑﻪ ﺻﻨﺪﻭﻕ ﭘﺴــﺘﯽ ۱۴۳۳۵-۵۳۶ﻭ ﯾﺎ ﺩﻭﺭﻧﮕﺎﺭ ۰۲۱-۲۲۸۸۵۶۵۱ﺍﺭﺳــﺎﻝ ﻧﻤﺎﯾﯿﺪ. ﻻﺯﻡ ﺑﻪ ﺫﮐﺮ ﺍﺳﺖ ﺑﺎﺑﺖ ﺧﺮﯾﺪ ﺑﯿﺶ ﺍﺯ ۵۰ﻫﺰﺍﺭ ﺗﻮﻣﺎﻥ ،ﻫﺰﯾﻨﻪ ﭘﺴﺘﯽ ﺑﻪ ﻋﻬﺪﻩ ﯾﺰﺩﺍ ﻣﯽﺑﺎﺷﺪ .ﺩﺭ ﻏﯿﺮ ﺍﯾﻦﺻﻮﺭﺕ ﻻﺯﻡ ﺍﺳﺖ ﻋﻼﻭﻩ ﺑﺮ ﻫﺰﯾﻨﻪ ﮐﺘﺎﺏ ﺩﺭﺧﻮﺍﺳﺘﯽ ،ﻣﺒﻠﻎ ۵ﻫﺰﺍﺭ ﺗﻮﻣﺎﻥ ﻧﯿﺰ ﺩﺭ ﻓﯿﺶ ﺑﺎﻧﮑﯽ ﻟﺤﺎﻅ ﮔﺮﺩﺩ. ﺟﻬﺖ ﺗﻬﯿﻪ ﺣﻀﻮﺭﯼ ﮐﺘﺎﺏﻫﺎ ﻭ ﻧﺸﺮﯾﺎﺕ ﻧﯿﺰ ﻣﯽﺗﻮﺍﻧﯿﺪ ﺑﻪ ﺩﻓﺘﺮ ﻧﺸﺮ ﯾﺰﺩﺍ ﻣﺮﺍﺟﻌﻪ ﻓﺮﻣﺎﯾﯿﺪ.
¸§¶ ® ¶¨ ¶¢ ·¥È® :ß· ë©Ó ....................... ÀëÝ¢Ý áÍí À ¶ ® ¶¨ ¶¢ ·¥È® :ß· ©Ó ....... (ASHRAE) ´ë¤¦± § À¤¢ëµ À ¶ ® ¶¨ ¶¢ ·¥È® :ß· ©Ó ..................... ¾¢ë±¿¶ À¤¢µ Àë ¸§¶ ® ¶¨ ¶¢ ·¥È® :ß· ë©Ó ....................... Ä· ©Í¶ ¦Òæ À ½¨ ¶¢ ·¥È® :ß· ë©Ó ................. ¸§¦¹ § ·¥¦Ï àé¯ Ù ª ¯¨ ¶¢ ·¥È® :ß· ë©Ó ........................ ®Ä¸È¤ § ¸È¤ À¶ »é ¸§¶ ® ¶¨ ¶¢ ·¥È® :ß· ë©Ó ............................. ¥¸È¤ ¦±« À
ﻧﺎﻡ ﻭ ﻧﺎﻡ ﺧﺎﻧﻮﺍﺩﮔﯽ /ﺷــﺮﮐﺖ ................................................ :ﺗﻠﻔﻦ ............................... :ﺗﻠﻔﻦ ﻫﻤﺮﺍﻩ ............................... : ﻧﺸﺎﻧﯽ.............................................................................................................................................................. : ...................................................................................................................................................................... ........................................................................................................................................................... ﮐﺪ ﭘﺴــﺘﯽ ﺩﻩ ﺭﻗﻤﯽ )ﺍﻟﺰﺍﻣﯽ ﺍﺳﺖ( ............................................... :ﭘﺴــﺖ ﺍﻟﮑﺘﺮﻭﻧﯿﮏ.......................................................... : ﻓﯿﺶ ﺑﺎﻧﮑﯽ ﺷــﻤﺎﺭﻩ ....................................ﻣﻮﺭﺥ .......................ﺑﻪ ﻣﺒﻠﻎ ..............................ﺑﺮ ﻋﻬﺪﻩ ﺑﺎﻧﮏ ..................... : ¤¦ÜÕ
ÀÝ¢Ý áÍí
´¤¦± § À¤¢µ
¾¢±¿¶ À¤¢µ
Ä· ©Í¶ ¦Òæ
¸§¦¹ § ·¥¦Ï
®Ä¸È¤ § ¸È¤
«¥¸È¤ ¦±
½............................................................................................................................................................ : ®Ù ª ...................................................................................................................................................................... ............................................................................................................................................................
¸¯¥¸È¤ ¨ ©ª« -
ß· ©Ó - Ä· ª À¼¢½ - ¨¥· ± ·¥ ¨ ¹ « - ¨¥´«´ - ¨¥¦µ :°© ¥¸ ß Ûܤ ©Õ § ¦ëÜÕ ¦ª
( )
- :äæ»
¸¯¡¢ë ÀÊ±Ë - ß· ©Ó - ä ¤× áܵ¹ À¼¢½ - 䤸·§¦¯ ¨ ¹ « - ÙÐÊÕ¥ - ¨¥¦µ :°© ¥¸ ß Ûܤ ©Õ § £Ø ¦ª
( )
- :äæ»
¼¥¸È¤ Ù ª½ ·È¹ ß ÛÓ§¦¯ Ú¸¥ Õ Â ´©ç¶ ´ ´ µÓ ·¥¢»¹ Ä¥´ª¹¥ Ú¨ Û®¦¯ ߥ·· µ
( ) - :äæ»
¯¦§:¸Èë¤ ß ÛÓ
E-MAIL: YAZDA@HVAC.IR
WWW.HVAC.IR
WWW.YAZDA.IR