Ducted Split (50Hz/R22) TA5CUN2-02A(Replaces 5CUN2-01A)
TA5CUN2-01A
Introduction
General Description Thank you very much for your special patronage of LG air conditioners. LG's "Ducted Split" is one of the part of Unitary range meant for high load applications. It has separate outdoor unit. The Indoor unit can be placed inside in an isolated space. This also gives variety of air flow and offers flexibility in installation. The unit is used along with ducts and has flexible air flow as per installation conditions. The ranges go from 3 to 20 RT and most of the range is Cooling Only type. Long refrigerant piping offers additional advantage indoor and outdoor units to have long distance in between. Apart from common features, this unit offers some unique features like Multi Speed blower, Light weight & Compact design, Long refrigerant piping etc. A lot of information regarding the design & installation of this system is provided in this publication. This new products series contains data on the same pattern. Please utilize all the information for conducting your business efficiently. Make sure the specification, dimension or others technical data are same as provided in enginering data book before you start the project. We look forward to your continuing support.
LG Electronics Inc. Air Conditioning Division
3~12.5RT
Ducted Split
1
Introduction
TA5CUN2-01A
Publication history Pub. No.
TA5CUN2-01A
2
Frequency Category
50Hz
CAC
Type
Product name
Refrigerant
Single
Ducted Split
R22
Models 3~5RT
Ducted Split
7.5~20RT
Notes
New edition of EPD
Published in
May.2009
3~12.5RT
Ducted Split Introduction
CONTENTS Part 1. 3~5RT .......................................................................................1-1
Part 2. 7.5~12.5RT ...............................................................................2-1
Part3. 15~20RT ..................................................................................3-1
3~12.5RT
Ducted Split
3
Part 1 3~5RT
1. Models List ......................................................................................................................1-2 2. Model Number Nomenclature ..........................................................................................1-3 3. Feature & Benefits ...........................................................................................................1-4 4. List of Functions ...............................................................................................................1-7 5. Specifications ................................................................................................................... ...1-8 6. Dimensional Drawings .....................................................................................................1-9 7. Type of Applications .......................................................................................................1-11 8. Wiring Diagrams.............................................................................................................1-12 9. Selection Procedure.......................................................................................................1-15 10. Performance Data ........................................................................................................1-19 11. Electrical Data ..............................................................................................................1-29 12. Temperature, Pressure Chart.......................................................................................1-31 13. Refrigerant Cycle Diagrams .........................................................................................1-33 14. Operation Range..........................................................................................................1-34 15. Operating Space Limitations ........................................................................................1-35 16. The coefficient of Capacity Change .............................................................................1-36 .. .......................................................................................1-37 17. Mechanical Specifications 18. Appendix.......................... ............................................................................................1-38
3~5RT
Ducted Split
1-1
Models List
TA5CUN2-01A
0RGHOV /LVW &RROLQJ 2QO\ 1RPLQDO &DSDFLW\ 57
5HIULJHUDQW
1-2
3RZHU 6XSSO\
0RGHO 0RGHO 1DPH
‘ 9 +]
71 & 6$ 5
71 & 6$
‘ 9 +]
71 & 6$
Ducted Split
3~5RT
Model Number Nomenclature
TA5CUN2-01A
2. Model Number Nomenclature T N - C 0 6
0 8 S A 0
Development Sequence
A: Gold Fin B: Basic
Outdoor Fan Discharge S: Side Discharge T: Top Discharge Electric Standard (Volts / Freq. / Phase) 8 : 380-415V / 50Hz / 3Ă˜ Cooling Capacity 036 : 36 000 Btu/h
048 : 48 000 Btu/h
060 : 60 000 Btu/h
Model Type C: Cooling Only H: Heat Pump
Type of Air Conditioner TN: LGETA Ducted Split Air Conditioner
3~5RT
Ducted Split
1-3
Features & Benefits
TA5CUN2-01A
3. Features & Benefits
Air Handlers
Condensing Units
• 4 way convertibility-horizontal(Left & right), up-flow, down-flow.
• High-reliability compressor
• Plastic drain pan
• Side air-discharge
• High efficient evaporator coil
• Outside pressure taps for refrigerant system check
• Galvanized steel with painting
• Factory supplied charge of R22
• Washable and anti-fungus filter
• Energy Saving Gold Fin(Optional)
• Compressor internal overload protection
• Direct drive motor • Insulated cabinet • Cooling & fan operation
• Accessory Electric heater* Electric Thermostat*
1-4
Ducted Split
3~5RT
Features & Benefits
TA5CUN2-01A
Durable, dependable components Waterproof cabinets are constructed of galvanized steel with powder coating. Compact size enables the unit to be installed in limited space. Condenser fin guard is designed for safety against sharp edge of outdoor coil. Tight Top Cover and Cabinet - The units incorporate two or three layers top cover. The two or three piece layers overlaps in such a way that water cannot leak into the unit. These overlapped edges are gasketed and sealed to ensure water resistance and leak proof system.
Product quality and reliability • LG Ducted split unit have been rigorously life tested at the factory more than 1 500 hours. • All of LG Outdoor units were rigorously rain tested at the factory to ensure water tight integrity. • Actual shipping tests are performed to determine the best packing. Units are shipped around the country to obtain the best packaging test result. These test assure that the unit will arrive at your job site in best condition. • We perform 100% coil leak test at the factory. The indoor coil and outdoor coils are leak tested at 200psig and pressure tested to 500psig respectively. • Every unit goes under full run test to meet LG standards requirements. • Before units are shipped, 5 units which are selected by sampling are STLT(Short Time Life Test) tested more than 300 hours. • All LG Ducted split units undergo overload cooling tested(ambient temp is 129 F). In this condition, units operated continuously without any problem.
3~5RT
Ducted Split
1-5
Features & Benefits
TA5CUN2-01A
Basic & Optional Features Cooling & Fan Operation : - LG ducted split air conditioners can provide cooling & fan operation. In the cooling mode, it cools the air with an operation range of 18~30°C. In the fan operation mode, only indoor fan at the selected speed will run, outdoor fan and compressor will be off.
Electric Heater: (Accessory) - Electric Heater can be used to provide heat in addition to cycle heat. It also provides quick heating. It can also work as a stand alone heater with only fan operation.
Electronic Thermostat: (Accessory)
Room Temp
Set Temp
- It provides on/off timer up to 24 hours. Also self-
Cool Heat
diagnose the problem.
System
System
Fan
Heater
Timer
Auto On Auto On
Fan Heater
On/Off
Timer
Gold Fin TM Anti Corrosion [Salt spray test for 15 days]
- LG’s Outdoor Heat Exchanger is coated with a golden anti-corrosive epoxy treatment on the aluminum coil to minimized corrosion. This maintains heat transfer pro-
After 15 days
LG Gold Fin ™ Anti Corrosion
After 15 days
Conventional starting to corrode
perties of the coil for an extended time where as nonGold Fin coils progressively lose efficiency due to sur-
Gold fin
face corrosion. Standard on every LG air conditioner, This assists in areas suffering from pollution or near the ocean where the unit may subjected to higher levels of salt. Uncoated aluminum
1-6
Ducted Split
3~5RT
List of Functions
TA5CUN2-01A
4. List of Functions Model No.
TN-C0368SA0, TN-C0488SA0,TN-C0608SA0
Features Cooling & Fan Operation
O
Auto Restart Operation
-
Wired Remote Control
-
Group Control
-
Child Lock Function
-
Self Diagnosis Function
-
Weekly Program
-
Time Delay Relay
O
Two Thermistor Control
-
Central Control
-
Zone Control
-
Energy Saving Gold Fin
Optional
Wireless Remote Control
-
Electric Heater
Accessory
Fire Alarm Function
-
Electronic Thermostat
Accessory
Low Pressure Switch
-
High Pressure Switch
O
Phase Protection
O
Notes: • O: Basic • Optional: Factory-installed • Accessory: Field-installed • -: Not available on this system
3~5RT
Ducted Split
1-7
Specifications
TA5CUN2-01A
5. Specifications Nominal RT Models
(RT)
Gross Cooling Capacity Capacity Net Cooling Capacity Electrical Data
Performance
Power Supply M.C.A(with standard motor) Power Input Air Circulation EER SEER Sound Rating Type
Cooling Cooling Nominal CFM Cooling Cooling
Btu/h kcal/h(W) Btu/h kcal/h(W) V,PH,Hz Amps W CFM Btu/h.W Btu/h.W bell inch mm
Tube size(O.D) Indoor Coil
Row / Column / FPI inch mm sq.ft m2
Length Face area Type No. Used Diameter ( Width ) Indoor Fan Drive Type / Motor Step No.motors Motor output(standard / oversized) Motor rpm(Standard / oversized) No of Outdoor Units Type Quantity Model Maker Compressor Capacity Motor Type Motor Input Oil Type Oil Charge Type
inch
Hp rpm
kcal/h(Btu/h) W cc inch mm
Tube size(O.D) Outdoor Coil
Row / Column / FPI inch mm sq.ft m2
Length Face area Type No. Used / Diameter(inch) Drive Type Outdoor Fan CFM Discharge No. Motor / Motor output(Hp) Motor RPM Liquid Service Valve Gas Liquid Connecting Tube Gas Length(Standard) Dehumidification Rate Drain Connection Size Refrigerant
Refrigerant Charge
Side / Top
inch(mm) inch(mm) inch(mm) inch(mm) inch(m) l/h inch(mm) kg lbs Type
Refrigerant Control Indoor unit (W * H * D) Dimensions Outdoor unit (W * H * D) Packing Dimensions
Indoor unit (W * H * D) Outdoor unit (W * H * D) Indoor unit
Net Weight Outdoor unit Stuffing Quantity
Without S/Parts
(20ft / 40ft / 40ft HI)
inch mm inch mm mm mm kg lbs kg lbs
3 TN-C0368SA0 37 000 9 325(10 843) 35 500 8 947(10 404) 380 / 415,3,50 9.7 4 100 1 150 10.1 6 Fin&tube 3/8 9.52 2R / 34C / 18FPI 15 5/32 385 3.55 0.33 Centrifugal Blower 1EA 11 5/32 (7 7/32) Direct / 1 1EA 0.35 / N.A 870 / N.A 1 Scroll 1 JT125GABY1L DAKIN 11 867(40 500) Three Phase 3 400 SUNISO 4GSDID 1 400 Fin&tube 9/32 7 2R / 36C / 18FPI 32.74 831.5 6.67 0.62 Propeller 1EA / 18 1/8 Direct 1 872 Side 1EA / 0.12 850 3/8(9.52) 5/8(15.88) 3/8(9.52) 5/8(15.88) 295 9/32(7.5) 3 3/4(19.05) 2.1 4.63 R22 Capillary Tube 18 1/2 * 39 15/16 * 18 7/8
4 TN-C0488SA0 49 500 12 475(14 506) 47 000 11 845(13 774) 380 / 415,3,50 13.9 5 000 1 800 10.8 6.2 Fin&tube 3/8 9.52 3R / 40C / 18FPI 15 3/4 400 4.63 0.43 Centrifugal Blower 1EA 11 5/32 (10 5/8) Direct / 1 1EA 0.47 / N.A 950 / N.A 1 Scroll 1 JT160BCBY1L DAKIN 13 050(51 800) Three Phase 4 600 SUNISO 4GSDID 1 600 Fin&tube 3/8 9.52 2R / 22C / 18FPI*2EA 35.35 898 10.75 1.00 Propeller 2EA / 18 1/8 Direct 1 872*2 Side 2EA / 0.12 850 3/8(9.52) 3/4(19.05) 3/8(9.52) 3/4(19.05) 295 9/32(7.5) 3.7 3/4(19.05) 4.5 9.91 R22 Capillary Tube 23 5/8 * 44 11/16 * 19 11/16
5 TN-C0608SA0 60 000 15 121(17 584) 57 000 14 365(16 705) 380 / 415,3,50 16.5 5 800 1 900 10.1 6.2 Fin&tube 3/8 9.52 3R /40C / 18FPI 15 3/4 400 4.63 0.43 Centrifugal Blower 1EA 11 5/32 (10 5/8) Direct / 1 1EA 0.74 / N.A 1140 / N.A 1 Scroll 1 C-SB453H8 SANYO 15 222(60 400) Three Phase 5 430 SAY56T 1 700 Fin&tube 3/8 9.52 2R / 22C / 18FPI*2EA 35.35 898 10.75 1.00 Propeller 2EA / 18 1/8 Direct 1 872*2 Side 2EA / 0.12 850 1/2(12.7) 3/4(19.05) 1/2(12.7) 3/4(19.05) 295 9/32(7.5) 4.2 3/4(19.05) 4.2 9.25 R22 Capillary Tube 23 5/8 * 44 11/16 * 19 11/16
470 * 1 014 * 480
600 * 1 135 * 500
34 1/4 * 31 1/2 * 12 19/32
35 7/16 * 44 11/16 * 14 1/2
35 7/16 * 44 11/16 * 14 1/2
900 * 1135 * 370 664 * 1190 * 598 1040 * 1200 * 446 63 139 100 221 14 / 30 / 60
900 * 1135 * 370 664 * 1190 * 598 1040 * 1200 * 446 65 143 115 254 14 / 30 / 60
870 * 800 * 320 578 * 1072 * 542 1002 * 850 * 422 59 130 65 143 33 / 70 / 86
600 * 1 135 * 500
Note : 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27.0 (80.6째F ) DB/19.0 (66.2째F) WB - Outdoor Temperature 35 (95째F) DB/24 (75.2째F) WB Piping Length - Interconnecting Piping Length 7.5m '- Level Difference of Zero 2. Nominal CFM : Fan operation mode with clean filter, dry coil. 3. The specification may be subject to change without prior notice for purpose of improvement.
1-8
Ducted Split
3~5RT
Dimensional Drawings
TA5CUN2-01A
6. Dimensional Drawings Model No.: TN-C0368SA0 79
1. Indoor Unit
294
314
25
Air Outlet Vent
158
Condensate Drain-Horizontal 3/4" NPT-Female
1014
SuGas ctionSide line
32 221 50 485 Liquid Liqid lline i ne
480 110 160
45
43
Filter Provision
470 52 Condensate Drain-Upflow 3/4" NPT-Female
Air Inlet Vent
(Unit:mm)
2. Outdoor Unit
800 *DV 6LGH 6HUYLFH 9DOYH ÉŽ LQFK
/LTXLG 6LGH 6HUYLFH 9DOYH ÉŽ LQFK
546
320
870
3~5RT
(Unit:mm)
Ducted Split
1-9
Dimensional Drawings
TA5CUN2-01A
Model No.: TN-C0488SA0 , TN-C0608SA0 1. Indoor Unit
136 295
329
25
Air Outlet Vent
172
Condensate Drain-Horizontal 3/4" NPT-Female
1135
Suction Gas Side line
38 285 71 584 Liquid Liqid Side line
500
I 170
54
64
Filter Provision
600 58
240
Air Inlet Vent
Condensate Drain-Upflow 3/4" NPT-Female
(Unit:mm)
2. Outdoor Unit
1 135 Gas Side Service Valve (Ø3/4 inch) Liquid Side Service Valve(TN-C0488SA0 Ø3/8 inch) (TN-C0608SA0 Ø1/2 inch)
550 900
1-10
370
Ducted Split
(Unit:mm)
3~5RT
Type of Applications
TA5CUN2-01A
Modelヒ傍N-C0368SA0 , TN-C0488SA0 , TN-C0608SA0
3~5RT
Ducted Split
1-11
Wiring Diagrams
TA5CUN2-01A
8. Wiring Diagrams Model No.: TN-C0368SA0
INDOOR UNIT DIAGRAM WIRING
L
AC 24V
N 1
Fan
TRANS
GN/YL
TO OUTDOOR UNIT
N
Comp
BL BL
WH
RD
BK
RD
2
Heater
T
BK
ELECTRO-MECHANICAL THERMOSTAT
PILLAR TERMINAL
OR
3
AC 24V
R
Fan
BL
G
Comp
Y
Heater FUSE
BK
BL
MECHANICAL THERMOSTAT
BK
TB1
W
NOTE BK:BLACK RE:RED WH:WHITE OR:ORANGE YL:YELLOW BR:BROWN BL:BLUE GN/YL:GREEN/YELLOW MC:MAGNETIC CONTACTOR FM0:FAN MOTOR Ry:RELAY C0:CAPACITOR T:TIMER PWB TS:THERMOSTAT EH:ELECTRIC HEATER
TB2
BK A Ry B OR BL RD
USING ELECTRIC HEATER
Ry
3 Ø, 4 WIRE, 380/415V ,50Hz POWER SUPPLY
TS
R S T N
C0
TB6
YL BR OR
MC
RD
TB5
MC TB3
YL BR OR BK
EH
FM0
1-12
P/NO:3854A22214A
Ducted Split
3~5RT
TA5CUN2-01A
Wiring Diagrams
Model No.: TN-C0488SA0
INDOOR UNIT DIAGRAM WIRING
L
AC 24V
N 1
Fan
TRANS
GN/YL
TO OUTDOOR UNIT
N
Comp
BL BL
WH
RD
BK
RD
2
Heater
T
BK
ELECTRO-MECHANICAL THERMOSTAT
PILLAR TERMINAL
OR
3
AC 24V
R
Fan
BL
G
Comp
Y
Heater FUSE
BK
BL
MECHANICAL THERMOSTAT
BK
TB1
W
NOTE BK:BLACK RE:RED WH:WHITE OR:ORANGE YL:YELLOW BR:BROWN BL:BLUE GN/YL:GREEN/YELLOW MC:MAGNETIC CONTACTOR FM0:FAN MOTOR Ry:RELAY C0:CAPACITOR T:TIMER PWB TS:THERMOSTAT EH:ELECTRIC HEATER
TB2
BK A Ry B OR BL RD
USING ELECTRIC HEATER
Ry
3 Ø, 4 WIRE, 380/415V ,50Hz POWER SUPPLY
TS
R S T N
C0
TB6
YL BR OR
MC
RD
TB5
MC TB3
YL BR OR BK
EH
FM0
P/NO:3854A22214A
z
TO INDOOR UNIT
3~5RT
Ducted Split
1-13
TA5CUN2-01A
Wiring Diagrams
Model No.: TN-C0608SA0 INDOOR UNIT DIAGRAM WIRING
L
AC 24V
N 1
Fan
TRANS
GN/YL
TO OUTDOOR UNIT
N
Comp
BL BL
WH
RD
BK
RD
2
Heater
T
BK
ELECTRO-MECHANICAL THERMOSTAT
PILLAR TERMINAL
OR
3
AC 24V
R
Fan
BL
G
Comp
Y
Heater FUSE
BK
BL
MECHANICAL THERMOSTAT
BK
TB1
W
NOTE BK:BLACK RE:RED WH:WHITE OR:ORANGE YL:YELLOW BR:BROWN BL:BLUE GN/YL:GREEN/ YELLOW MC:MAGNETIC CONTACTOR FM0:FAN MOTOR Ry:RELAY C0:CAPACITOR T:TIMER PWB TS:THERMOSTAT EH:ELECTRIC HEATER
TB2
BK A Ry B OR BL RD
USING ELECTRIC HEATER
Ry
3 Ø 4 WIRE 380/415V ,50Hz POWER SUPPLY
TS
R S T N
C0
TB6
YL BR OR
MC
RD
TB5
MC TB3
YL BR OR BK
EH
FM0
1-14
P/NO:3854A22214A
Ducted Split
3~5RT
TA5CUN2-01A
Selection Procedure
6HOHFWLRQ SURFHGXUH 6HOHFWLRQ SURFHGXUH &RROLQJ RQO\ (QJOLVK
&RROLQJ 6WHS
%DVHG RQ EXLOGLQJ V FRROLQJ ORDG FDOFXODWLRQ IURP $6+5$( RU DQ\ DSSURYHG VWDQGDUG PHWKRG D &RROLQJ &DSDFLW\ %WX K E 6HQVLEOH &RROLQJ &DSDFLW\ %WX K F +HDWLQJ &DSDFLW\ %WX K G 2XWGRRU (QWHULQJ DLU 7HPSHUDWXUH ) H ,QGRRU (QWHULQJ DLU 7HPS ' % : % ) ) I ,QGRRU DLU IORZ FIP J (OHFWULFDO &KDUDFWHULVWLFV 9 3K +] K ([WHUQDO VWDWLF SUHVVXUH LQ $T L ,QWHUFRQQHFWLQJ SLSLQJ OHQJWK P
6WHS
6HOHFW XQLW EDVHG RQ UHTXLUHG FRROLQJ FDSDFLW\ %DVHG RQ 7RWDO &RROLQJ &DSDFLW\ FKRRV H VXLWDEOH 0RGHO IURP VSHFLILFDWLRQ WDEOH 57 XQLW FDQ EH VHOHFWHG 9HULI\ WKH XQLW SHUIRUPDQFH DW WKH JLYHQ FRQGLWLRQV LQ DFFRUGDQFH ZLWK VWHS
6WHS
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
3~5RT
Ducted Split
1-15
Selection Procedure
TA5CUN2-01A
Selection Procedure Step 4.
The capacity estimated at step #3 is the gross capacity of the selected unit. The generated heat from indoor motor is a function of cfm & static pressure. The total unit static pressure is as follows: External Static(Duct system)
0.16 in.Aq.
Standard Filter
0.05 in.Aq.
Electric heater size 9kW
0.04 in.Aq.
Total static pressure
0.25 in.Aq.
Evaporator fan motor performance table has deducted the pressure drop for filter already in the unit. Therefore, the actual total static pressure is 0.20 in.Aq. With 1 900 cfm and 0.20 in.Aq, table-11 shows 0.60 BHP for this unit. FAN MOTOR HEAT; 5.09*BHP=MBH 5.09*0.60 =3.05MBH Now subtract the fan motor heat from the gross cooling capacity of the unit;
Step 5.
Net cooling capacity
60 MBH - 3.05MBH = 56.95 MBH
Net sensible cooling
45.6 MBH -3.05 MBH = 42.55MBH
• MBH = 1 000 Btu/h
If the selected unit performance will not meet the required load, either total or sensible cooling, the next higher size unit should be selected.
Electric Heating Step 1.
Calculate the building heating load using the ASHRAE calculation or from other standard accepted method.
Step 2.
The required heating capacity is 30 000 Btu/h. The electric heat acessory capacities are listed in table-14. From the table-14 select, 9 kW electric heater with output 30.72 MBH = 30 720Btu/h.
1-16
Ducted Split
3~5RT
TA5CUN2-01A
Selection Procedure
Selection Procedure-Cooling only(SI) Cooling Step 1.
Based on b uilding's cooling load calculation fr om ASHRAE or an y approved standard method. a. Cooling Capacity ...................................................................14.7 kW b. Sensible Cooling Capacity .....................................................11.7 kW c. Heating Capacity ...................................................................8.8 kW d. Outdoor Entering-air Temperature ........................................35°C e. Indoor Entering-air Temp.(D.B/W.B) .....................................26.7°C/19.4°C f. Indoor air-flow .........................................................................896 l/s g. Electrical Characteristics(V-Ph-Hz) .......................................380/415-3-50 h. External static pressure .........................................................4.32mm Aq. i. Interconnecting Piping length .................................................7.5m
Step 2.
Select unit based on required cooling capacity. Based on total cooling capacity, choose suitable Model from specification table. 5RT unit can be selected. Verify the unit performance at the given conditions in accordance with step #3.
Step 3.
From table-3 (TN-C0608SA0), at 896 l/s and 35°C DB outdoor ambient temperature, with 26.7°C DB. 19.4°C WB air entering temperature at indoor coil. Total cooling capacity= 17.6 kW, Sensible capacity = 13.4 kW To find capacity at intermediate conditions not in the table: Interpolation should be used when design conditions are between two numbers that are in the capacity table. Extra-polation is not recommended. If the Interconnecting piping length is more than 7.5m: Find the Capacity(%) at that Particular interconnecting pipe length from the Coefficient of Capacity change graph on page No.38. Multiply Capacity(%) with total Cooling Capacity & Sensible capacity. 100 ex: For TN-C0608SA0 at 30 m interconnecting pipe length, from coefficient of Capacity change graph, Capacity(%) is 91.50 So, Total Cooling Capacity = Capacity(%) x Total Cooling Capacity = 91.50x 17.6 = 16.104 kW 100 100 Capacity(%) x Sensible Capacity 91.50 x 13.4 Sensible Capacity = = = 12.261 kW 100 100
3~5RT
Ducted Split
1-17
TA5CUN2-01A
Selection Procedure
Selection Procedure
Step 4.
The capacity estimated at step #3 is the gross capacity of the selected unit. The generated heat from indoor motor is a function of l/s & static pressure. The total unit static pressure is as follows: External Static(Duct system)
4.06 mm Aq
Standard Filter
1.27 mm Aq
Electric heater size 9kw
1.02 mm Aq
Total static pressure
6.35 mm Aq
Evaporator fan motor performance table has deducted the pressure drop for filter already in the unit. Therefore, the actual total static pressure is 5.08mm Aq. With 896 l/s and 5.08mm Aq, table-12 shows 0.45 Bkw for this unit. FAN MOTOR HEAT; 2*Bkw=kw 2*0.45Bkw=0.9kw Now subtract the fan motor heat from the gross cooling capacity of the unit;
Step 5.
Net cooling capacity
17.6 kW - 0.9 kW = 17.7 kW
Net sensible cooling
13.4 kW - 0.9 kW = 12.5 kW
If the selected unit performance will not meet the required load, either total or sensible cooling, the next higher size unit should be selected.
Electric Heating Step 1.
Calculate the building heating load using the ASHRAE calculation or from other standard accepted method.
Step 2.
The required heating capacity is 8.8 kW (given). 12 x 8.8 = 30 MBH 8.8kW = 3.5167 The electric heat accessory capacities are listed in table-14. From the table select, 9kW Electric Heater with output 30.72MBH = 30 720Btu/h.
1-18
Ducted Split
3~5RT
TA5CUN2-01A
Performance Data
3HUIRUPDQFH 'DWD 7DEOH 2XWGRRU '% ć
,QGRRU :% ć
O V
'% ć 7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+&
3,
7*& 6+& 3,
2XWGRRU '% ć
,QGRRU :% ć
O V
*URVV &RROLQJ &DSDFLW\ N: 57 71 & 6$ 6,
'% ć 7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
1RWHV $OO FDSDFLWLHV DUH JURVV HYDSRUDWRU IDQ PRWRU KHDW LV QRW GHGXFWHG 7R REWDLQ QHW FRROLQJ FDSDFLW\ VXEWUDFW HYDSRUDWRU IDQ PRWRU KHDW '% 'U\ %XOE 7HPSHUDWXUH & :% :HW %XOE 7HPSHUDWXUH &
O V /LWHUV SHU VHFRQG 7*& 7RWDO *URVV &RROLQJ &DSDFLW\ 8QLW N:
6+& 6HQVLEOH +HDW &DSDFLW\ 8QLW N:
3, 3RZHU ,QSXW N: 6XP RI &RPSUHVVRU 2XWGRRU )DQ 3RZHU ,QSXW
3~5RT
Ducted Split
1-19
TA5CUN2-01A
Performance Data
7DEOH 2XWGRRU '% ć
,QGRRU :% ć
O V
*URVV &RROLQJ &DSDFLW\ N: 57 71 & 6$ 6,
'% ć 7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+&
3,
7*& 6+& 3,
2XWGRRU '% ć
,QGRRU :% ć
O V
'% ć 7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
1RWHV $OO FDSDFLWLHV DUH JURVV HYDSRUDWRU IDQ PRWRU KHDW LV QRW GHGXFWHG 7R REWDLQ QHW FRROLQJ FDSDFLW\ VXEWUDFW HYDSRUDWRU IDQ PRWRU KHDW '% 'U\ %XOE 7HPSHUDWXUH & :% :HW %XOE 7HPSHUDWXUH &
O V /LWHUV SHU VHFRQG 7*& 7RWDO *URVV &RROLQJ &DSDFLW\ 8QLW N:
6+& 6HQVLEOH +HDW &DSDFLW\ 8QLW N:
3, 3RZHU ,QSXW N: 6XP RI &RPSUHVVRU 2XWGRRU )DQ 3RZHU ,QSXW
1-20
Ducted Split
3~5RT
TA5CUN2-01A
Performance Data
7DEOH 2XWGRRU '% ć
,QGRRU :% ć
O V
'% ć 7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+& 3,
7*& 6+&
3,
7*& 6+& 3,
2XWGRRU '% ć
,QGRRU :% ć
O V
*URVV &RROLQJ &DSDFLW\ N: 57 71 & 6$ 6,
'% ć 7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
7*&
6+&
3,
1RWHV $OO FDSDFLWLHV DUH JURVV HYDSRUDWRU IDQ PRWRU KHDW LV QRW GHGXFWHG 7R REWDLQ QHW FRROLQJ FDSDFLW\ VXEWUDFW HYDSRUDWRU IDQ PRWRU KHDW '% 'U\ %XOE 7HPSHUDWXUH & :% :HW %XOE 7HPSHUDWXUH &
O V /LWHUV SHU VHFRQG 7*& 7RWDO *URVV &RROLQJ &DSDFLW\ 8QLW N:
6+& 6HQVLEOH +HDW &DSDFLW\ 8QLW N:
3, 3RZHU ,QSXW N: 6XP RI &RPSUHVVRU 2XWGRRU )DQ 3RZHU ,QSXW
3~5RT
Ducted Split
1-21
Performance Data
TA5CUN2-01A
Table-4 Outdoor DB(̧ ) Indoor WB(̧ ) CFM
95
85
1035
1150
1265
1380
61
1150
1265
1380
61
67
73
61
31.7 25.1 2.96 35.1 19.0 3.05 37.7 8.4 3.11 30.6 25.5 3.27 33.8 19.3 3.37 36.4 8.5 3.43 29.5 24.9 3.51 32.7 18.8 3.62 35.1 8.3 3.69
80
33.1 28.8 2.97 35.7 23.8 3.06 37.7 15.6 3.12 31.9 29.3 3.28 34.4 24.2 3.38 36.4 15.9 3.44 30.8 28.6 3.52 33.2 23.6 3.63 35.1 15.5 3.70
85
34.3 31.5 2.98 36.2 28.6 3.07 37.6 21.5 3.13 33.1 32.1 3.29 34.9 29.2 3.39 36.3 21.9 3.45 32.0 31.3 3.53 33.7 28.4 3.65 35.0 21.4 3.71
90
35.5 33.2 2.99 36.6 31.8 3.08 37.4 26.2 3.14 34.2 33.8 3.30 35.3 32.4 3.40 36.1 26.7 3.46 33.0 33.0 3.54 34.1 31.6 3.66 34.8 26.0 3.72
75
33.2 26.7 2.99 36.7 20.2 3.08 39.5 8.9 3.14 32.0 27.3 3.29 35.4 20.6 3.40 38.1 9.1 3.46 30.9 26.6 3.54 34.2 20.1 3.65 36.7 8.9 3.72
80
34.6 30.7 3.00 37.4 25.4 3.09 39.5 16.6 3.15 33.4 31.3 3.30 36.0 25.8 3.41 38.1 16.9 3.47 32.2 30.5 3.55 34.8 25.2 3.66 36.8 16.5 3.73
85
35.9 33.7 3.00 37.9 30.5 3.10 39.4 23.0 3.16 34.7 34.3 3.31 36.6 31.1 3.42 38.0 23.4 3.48 33.5 33.4 3.56 35.3 30.3 3.67 36.7 22.8 3.74
90
37.1 35.4 3.01 38.3 33.9 3.11 39.1 28.0 3.17 35.8 35.8 3.32 37.0 34.6 3.43 37.7 28.5 3.49 34.6 34.6 3.57 35.7 33.7 3.68 36.4 27.8 3.75
75
34.1 28.7 3.01 37.7 21.7 3.11 40.5 9.6 3.16 32.9 29.3 3.33 36.3 22.2 3.43 39.1 9.8 3.50 31.7 28.5 3.56 35.1 21.6 3.68 37.7 9.5 3.74
80
35.6 33.0 3.02 38.4 27.2 3.12 40.5 17.8 3.17 34.3 33.6 3.34 37.0 27.8 3.45 39.1 18.2 3.51 33.1 32.7 3.57 35.7 27.0 3.69 37.7 17.7 3.76
85
36.9 36.1 3.03 38.9 32.8 3.13 40.4 24.7 3.18 35.6 35.6 3.35 37.5 33.4 3.46 39.0 25.1 3.52 34.4 34.4 3.59 36.2 32.6 3.70 37.6 24.5 3.77
90
38.1 38.1 3.04 39.3 36.4 3.13 40.2 30.0 3.19 36.8 36.8 3.36 37.9 37.1 3.47 38.7 30.6 3.53 35.5 35.5 3.60 36.6 36.2 3.71 37.4 29.8 3.78
75
34.7 30.1 3.04 38.3 22.8 3.13 41.2 10.0 3.19 33.4 30.6 3.34 37.0 23.2 3.45 39.7 10.2 3.51 32.3 29.9 3.59 35.7 22.6 3.70 38.4 10.0 3.77
80
36.2 34.5 3.05 39.0 28.5 3.14 41.2 18.7 3.20 34.9 34.9 3.35 37.6 29.1 3.46 39.8 19.0 3.52 33.7 33.7 3.60 36.3 28.3 3.71 38.4 18.5 3.78
85
37.5 37.5 3.06 39.6 34.3 3.15 41.1 25.8 3.21 36.2 36.2 3.36 38.2 35.0 3.47 39.7 26.3 3.53 34.9 34.9 3.61 36.8 34.1 3.73 38.3 25.6 3.79
90
38.8 38.8 3.06 40.0 38.1 3.16 40.9 31.4 3.22 37.4 37.4 3.37 38.6 38.6 3.48 39.4 32.0 3.54 36.1 36.1 3.62 37.2 37.2 3.74 38.0 31.2 3.81
75
35.1 31.0 3.06 38.8 23.5 3.16 41.7 10.4 3.22 33.9 31.6 3.37 37.4 23.9 3.47 40.3 10.6 3.54 32.7 30.8 3.62 36.1 23.3 3.73 38.8 10.3 3.80
80
36.6 35.6 3.07 39.5 29.4 3.17 41.7 19.3 3.23 35.3 35.3 3.38 38.1 30.0 3.48 40.3 19.6 3.55 34.1 34.1 3.63 36.8 29.2 3.74 38.9 19.1 3.81
85
38.0 38.0 3.08 40.1 35.4 3.18 41.6 26.6 3.24 36.7 36.7 3.39 38.7 36.1 3.50 40.2 27.1 3.56 35.4 35.4 3.64 37.3 35.2 3.75 38.8 26.5 3.82
90
39.3 39.3 3.09 40.5 39.3 3.19 41.4 32.4 3.25 37.9 37.9 3.40 39.1 39.1 3.51 39.9 33.1 3.57 36.5 36.5 3.65 37.7 37.7 3.76 38.5 32.2 3.83 115 61
DB(̧ ) TGC
1035
73
75
Outdoor DB(̧ ) Indoor WB(̧ )
920
67
105
73 67 DB(̧ ) TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI
920
CFM
Gross Cooling Capacity (MBH) 3RT TN-C0368SA0(English)
125
67
73
61
67
73
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
75
27.9
24.2
3.72
30.8
18.3
3.83
33.1
8.1
3.91
25.8
23.1
3.89
28.5
17.5
4.01
30.7
7.7
4.09
80
29.1
27.8
3.73
31.4
23.0
3.85
33.1
15.0
3.92
26.9
26.5
3.90
29.1
21.9
4.02
30.7
14.4
4.10
85
30.2
30.2
3.74
31.8
27.7
3.86
33.0
20.8
3.93
28.0
28.0
3.91
29.5
26.4
4.04
30.6
19.9
4.11
90
31.2
31.2
3.75
32.2
30.7
3.87
32.8
25.3
3.94
28.9
28.9
3.92
29.8
29.3
4.05
30.4
24.2
4.12
75
29.2
25.8
3.74
32.2
19.6
3.86
34.7
8.6
3.93
27.0
24.7
3.91
29.9
18.7
4.04
32.1
8.2
4.11
80
30.4
29.7
3.75
32.8
24.5
3.87
34.7
16.1
3.94
28.2
28.2
3.93
30.4
23.4
4.05
32.1
15.3
4.12
85
31.6
31.6
3.77
33.3
29.5
3.88
34.6
22.2
3.96
29.3
29.3
3.94
30.8
28.2
4.06
32.0
21.2
4.14
90
32.6
32.6
3.78
33.7
32.8
3.90
34.4
27.0
3.97
30.2
30.2
3.95
31.2
31.2
4.07
31.8
25.8
4.15
75
29.9
27.8
3.77
33.1
21.0
3.89
35.6
9.3
3.96
27.7
26.5
3.94
30.7
20.1
4.06
33.0
8.9
4.14
80
31.2
31.2
3.78
33.7
26.3
3.90
35.6
17.2
3.97
28.9
28.9
3.95
31.2
25.1
4.08
33.0
16.5
4.15
85
32.4
32.4
3.79
34.2
31.7
3.91
35.5
23.8
3.98
30.0
30.0
3.96
31.7
30.2
4.09
32.9
22.8
4.16
90
33.5
33.5
3.80
34.6
34.6
3.92
35.3
29.0
3.99
31.0
31.0
3.98
32.0
32.0
4.10
32.7
27.7
4.18
75
30.5
29.1
3.79
33.7
22.0
3.91
36.2
9.7
3.99
28.2
27.7
3.97
31.2
21.0
4.09
33.5
9.3
4.17
80
31.8
31.8
3.81
34.3
27.6
3.93
36.2
18.0
4.00
29.4
29.4
3.98
31.7
26.3
4.10
33.5
17.2
4.18
85
33.0
33.0
3.82
34.8
33.2
3.94
36.1
25.0
4.01
30.5
30.5
3.99
32.2
31.7
4.11
33.4
23.8
4.19
90
34.1
34.1
3.83
35.1
35.1
3.95
35.9
30.4
4.02
31.5
31.5
4.00
32.5
32.5
4.13
33.2
29.0
4.20
75
30.8
30.0
3.82
34.1
22.7
3.94
36.7
10.0
4.01
28.6
28.6
3.99
31.6
21.7
4.12
34.0
9.6
4.19
80
32.2
32.2
3.83
34.7
28.4
3.95
36.7
18.6
4.03
29.8
29.8
4.00
32.2
27.1
4.13
34.0
17.8
4.21
85
33.4
33.4
3.84
35.2
34.2
3.96
36.6
25.7
4.04
30.9
30.9
4.01
32.6
32.6
4.14
33.9
24.6
4.22
90
34.5
34.5
3.85
35.6
35.6
3.98
36.4
31.4
4.05
31.9
31.9
4.03
33.0
33.0
4.15
33.7
29.9
4.23
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1 000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1 000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
1-22
Ducted Split
3~5RT
TA5CUN2-01A
Performance Data
Tab le-5
Gross Cooling Capacity (MBH) 4RT TN-C0488SA0(English)
Indoor WB(̧ ) 61 67 73 61 67 73 61 67 73 CFM DB(̧ ) TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI
1440
1620
1800
1980
2160
75
42.4 33.5 3.83 46.9 25.4 3.95 50.4 11.2 4.03 40.9 34.2 4.23 45.3 25.9 4.36 48.7 11.4 4.44 39.5 33.3 4.55 43.7 25.2 4.69 47.0 11.1 4.78
80
44.3 38.5 3.84 47.8 31.8 3.97 50.5 20.8 4.04 42.7 39.2 4.24 46.1 32.4 4.37 48.7 21.2 4.46 41.2 38.2 4.56 44.5 31.6 4.71 47.0 20.7 4.79
85
45.9 42.2 3.86 48.5 38.3 3.98 50.3 28.8 4.05 44.3 43.0 4.25 46.7 39.0 4.39 48.5 29.4 4.47 42.8 41.9 4.58 45.1 38.0 4.72 46.9 28.6 4.81
90
47.5 44.4 3.87 49.0 42.5 3.99 50.0 35.1 4.06 45.8 45.3 4.27 47.2 43.4 4.40 48.3 35.7 4.48 44.2 44.1 4.59 45.6 42.3 4.73 46.6 34.8 4.82
75
44.4 35.8 3.87 49.1 27.1 3.99 52.8 12.0 4.06 42.8 36.5 4.26 47.4 27.6 4.40 50.9 12.2 4.48 41.3 35.5 4.58 45.7 26.9 4.73 49.1 11.9 4.81
80
46.3 41.1 3.88 50.0 33.9 4.00 52.8 22.2 4.07 44.7 41.9 4.27 48.2 34.6 4.41 50.9 22.6 4.49 43.1 40.8 4.59 46.5 33.7 4.74 49.2 22.1 4.83
85
48.1 45.0 3.89 50.7 40.9 4.01 52.7 30.7 4.09 46.4 45.9 4.29 48.9 41.6 4.42 50.8 31.3 4.50 44.8 44.7 4.61 47.2 40.6 4.75 49.0 30.5 4.84
90
49.7 47.4 3.90 51.3 45.4 4.02 52.3 37.4 4.10 47.9 47.9 4.30 49.4 46.3 4.44 50.5 38.1 4.52 46.2 46.2 4.62 47.7 45.1 4.77 48.7 37.2 4.86
75
45.6 38.4 3.90 50.4 29.1 4.02 54.2 12.8 4.10 44.0 39.1 4.31 48.6 29.6 4.45 52.3 13.1 4.53 42.4 38.1 4.61 46.9 28.9 4.76 50.5 12.8 4.85
80
47.6 44.1 3.91 51.3 36.4 4.03 54.2 23.9 4.11 45.9 45.0 4.32 49.5 37.1 4.46 52.3 24.3 4.54 44.3 43.8 4.63 47.8 36.2 4.77 50.5 23.7 4.86
85
49.4 48.3 3.92 52.1 43.9 4.05 54.1 33.0 4.12 47.6 47.6 4.34 50.2 44.7 4.47 52.2 33.6 4.56 46.0 46.0 4.64 48.5 43.6 4.79 50.3 32.8 4.88
90
51.0 50.9 3.93 52.6 48.7 4.06 53.7 40.2 4.13 49.2 49.2 4.35 50.8 49.7 4.49 51.8 41.0 4.57 47.5 47.5 4.66 49.0 48.4 4.80 50.0 39.9 4.89
75
46.4 40.2 3.93 51.3 30.5 4.06 55.1 13.4 4.13 44.7 41.0 4.33 49.5 31.0 4.46 53.2 13.7 4.55 43.2 39.9 4.65 47.7 30.2 4.79 51.3 13.4 4.88
80
48.4 46.2 3.94 52.2 38.1 4.07 55.1 25.0 4.14 46.7 46.7 4.34 50.3 38.9 4.48 53.2 25.5 4.56 45.0 45.0 4.66 48.6 37.9 4.81 51.3 24.8 4.90
85
50.2 50.2 3.96 52.9 45.9 4.08 55.0 34.5 4.16 48.4 48.4 4.35 51.1 46.8 4.49 53.0 35.2 4.57 46.7 46.7 4.68 49.3 45.6 4.82 51.2 34.3 4.91
90
51.9 51.9 3.97 53.5 51.0 4.09 54.7 42.1 4.17 50.0 50.0 4.37 51.6 51.6 4.50 52.7 42.9 4.59 48.3 48.3 4.69 49.8 49.8 4.84 50.9 41.8 4.93
75
47.0 41.5 3.97 51.9 31.4 4.09 55.8 13.9 4.17 45.3 42.3 4.36 50.1 32.0 4.50 53.9 14.1 4.58 43.7 41.2 4.68 48.3 31.2 4.83 52.0 13.8 4.92
80
49.0 47.6 3.98 52.9 39.3 4.10 55.9 25.8 4.18 47.3 47.3 4.37 51.0 40.1 4.51 53.9 26.3 4.60 45.6 45.6 4.69 49.2 39.1 4.84 52.0 25.6 4.93
85
50.9 50.9 3.99 53.6 47.4 4.12 55.7 35.6 4.19 49.1 49.1 4.39 51.7 48.3 4.53 53.7 36.3 4.61 47.3 47.3 4.71 49.9 47.1 4.86 51.9 35.4 4.95
90
52.5 52.5 4.00 54.2 52.6 4.13 55.4 43.4 4.20 50.7 50.7 4.40 52.3 52.3 4.54 53.4 44.2 4.62 48.9 48.9 4.72 50.5 50.5 4.87 51.5 43.1 4.96
Indoor WB(̧ ) CFM DB(̧ ) TGC
1440
1620
1800
1980
2160
61
67
73
61
67
73
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
75
37.3
32.4
4.81
41.2
24.5
4.96
44.3
10.8
5.06
34.5
30.9
5.03
38.2
23.4
5.19
41.1
10.3
5.29
80
38.9
37.2
4.83
42.0
30.7
4.98
44.3
20.1
5.07
36.0
35.5
5.05
38.9
29.3
5.21
41.1
19.2
5.31
85
40.4
40.4
4.84
42.6
37.0
4.99
44.2
27.8
5.09
37.4
37.4
5.06
39.4
35.3
5.22
41.0
26.6
5.32
90
41.7
41.7
4.86
43.0
41.1
5.01
43.9
33.9
5.10
38.6
38.6
5.08
39.9
39.2
5.24
40.7
32.4
5.34
75
39.0
34.6
4.85
43.1
26.2
5.00
46.4
11.6
5.09
36.1
33.0
5.07
40.0
25.0
5.23
43.0
11.0
5.32
80
40.7
39.7
4.86
43.9
32.8
5.01
46.4
21.5
5.11
37.7
37.7
5.08
40.7
31.3
5.24
43.0
20.5
5.34
85
42.2
42.2
4.87
44.6
39.5
5.03
46.3
29.7
5.12
39.1
39.1
5.10
41.3
37.7
5.26
42.9
28.3
5.36
90
43.6
43.6
4.89
45.0
43.9
5.04
46.0
36.2
5.14
40.4
40.4
5.11
41.7
41.7
5.27
42.6
34.5
5.37
75
40.1
37.1
4.88
44.3
28.1
5.03
47.6
12.4
5.13
37.1
35.4
5.10
41.0
26.8
5.26
44.1
11.8
5.36
80
41.8
41.8
4.89
45.1
35.2
5.05
47.6
23.1
5.14
38.7
38.7
5.12
41.8
33.6
5.28
44.1
22.0
5.37
85
43.4
43.4
4.91
45.7
42.4
5.06
47.5
31.9
5.16
40.2
40.2
5.13
42.4
40.5
5.29
44.0
30.4
5.39
90
44.8
44.8
4.92
46.2
46.2
5.08
47.2
38.8
5.17
41.5
41.5
5.15
42.8
42.8
5.31
43.7
37.1
5.41
75
40.7
38.9
4.91
45.0
29.4
5.07
48.4
13.0
5.16
37.7
37.1
5.13
41.7
28.1
5.30
44.9
12.4
5.39
80
42.5
42.5
4.93
45.9
36.9
5.08
48.4
24.1
5.18
39.4
39.4
5.15
42.5
35.2
5.31
44.9
23.0
5.41
85
44.1
44.1
4.94
46.5
44.4
5.10
48.3
33.4
5.19
40.9
40.9
5.16
43.1
42.4
5.33
44.7
31.9
5.43
90
45.6
45.6
4.96
47.0
47.0
5.11
48.0
40.7
5.21
42.2
42.2
5.18
43.5
43.5
5.34
44.5
38.8
5.44
75
41.3
40.1
4.94
45.6
30.4
5.10
49.0
13.4
5.20
38.2
38.2
5.17
42.3
29.0
5.33
45.4
12.8
5.43
80
43.1
43.1
4.96
46.4
38.0
5.12
49.1
24.9
5.21
39.9
39.9
5.18
43.0
36.3
5.35
45.5
23.8
5.44
85
44.7
44.7
4.97
47.1
45.8
5.13
48.9
34.4
5.23
41.4
41.4
5.20
43.6
43.6
5.36
45.3
32.9
5.46
90
46.1
46.1
4.99
47.6
47.6
5.15
48.6
41.9
5.24
42.7
42.7
5.21
44.1
44.1
5.38
45.0
40.0
5.48
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1 000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1 000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
3~5RT
Ducted Split
1-23
TA5CUN2-01A
Performance Data
Tab le-6 Outdoor DB(̧ ) Indoor WB(̧ ) CFM
85
1710
1900
2090
2280
61
95
1900
2090
2280
61
67
73
61
51.4 40.6 4.27 56.9 30.8 4.41 61.1 13.6 4.49 49.6 41.4 4.71 54.9 31.4 4.86 59.0 13.8 4.95 47.9 40.4 5.07 52.9 30.6 5.23 56.9 13.5 5.32
80
53.7 46.7 4.28 57.9 38.5 4.42 61.2 25.2 4.50 51.8 47.6 4.73 55.9 39.3 4.87 59.0 25.7 4.97 50.0 46.3 5.08 53.9 38.3 5.24 57.0 25.1 5.34
85
55.7 51.1 4.30 58.7 46.4 4.43 61.0 34.9 4.51 53.7 52.1 4.74 56.7 47.3 4.89 58.8 35.6 4.98 51.9 50.8 5.10 54.7 46.1 5.26 56.8 34.7 5.36
90
57.5 53.9 4.31 59.4 51.6 4.45 60.6 42.5 4.53 55.5 54.9 4.75 57.3 52.6 4.90 58.5 43.3 5.00 53.6 53.5 5.11 55.3 51.2 5.28 56.4 42.2 5.37
75
53.8 43.4 4.31 59.5 32.8 4.44 64.0 14.5 4.53 51.9 44.2 4.75 57.4 33.5 4.90 61.7 14.8 4.99 50.1 43.1 5.10 55.4 32.6 5.27 59.6 14.4 5.36
80
56.2 49.8 4.32 60.6 41.1 4.46 64.0 26.9 4.54 54.2 50.7 4.76 58.4 41.9 4.91 61.8 27.4 5.00 52.3 49.5 5.12 56.4 40.8 5.28 59.6 26.7 5.38
85
58.3 54.6 4.33 61.5 49.5 4.47 63.8 37.2 4.55 56.2 55.6 4.78 59.3 50.5 4.93 61.6 38.0 5.02 54.3 54.2 5.14 57.2 49.2 5.30 59.4 37.0 5.40
90
60.2 57.5 4.35 62.1 55.0 4.48 63.4 45.4 4.57 58.1 58.1 4.79 59.9 56.1 4.94 61.2 46.2 5.03 56.0 56.0 5.15 57.8 54.6 5.31 59.1 45.1 5.41
75
55.3 46.6 4.35 61.1 35.3 4.48 65.7 15.6 4.57 53.3 47.5 4.80 58.9 35.9 4.96 63.4 15.9 5.05 51.5 46.2 5.14 56.9 35.0 5.30 61.2 15.5 5.40
80
57.7 53.5 4.36 62.2 44.2 4.50 65.7 28.9 4.58 55.6 54.5 4.82 60.0 45.0 4.97 63.4 29.5 5.06 53.7 53.1 5.16 57.9 43.9 5.32 61.2 28.7 5.42
85
59.8 58.6 4.37 63.1 53.2 4.51 65.5 40.0 4.59 57.7 57.7 4.83 60.9 54.2 4.98 63.2 40.8 5.08 55.7 55.7 5.17 58.7 52.8 5.34 61.0 39.7 5.43
90
61.8 61.7 4.38 63.8 59.1 4.52 65.1 48.7 4.61 59.6 59.6 4.85 61.5 60.2 5.00 62.8 49.6 5.09 57.5 57.5 5.19 59.4 58.7 5.35 60.6 48.4 5.45
75
56.2 48.7 4.38 62.1 36.9 4.52 66.8 16.3 4.60 54.2 49.7 4.82 59.9 37.6 4.97 64.5 16.6 5.07 52.3 48.4 5.18 57.9 36.7 5.34 62.2 16.2 5.44
80
58.6 56.0 4.40 63.3 46.2 4.53 66.8 30.3 4.62 56.6 56.6 4.84 61.0 47.1 4.99 64.5 30.9 5.08 54.6 54.6 5.19 58.9 45.9 5.36 62.2 30.1 5.46
85
60.9 60.9 4.41 64.2 55.7 4.55 66.7 41.9 4.63 58.7 58.7 4.85 61.9 56.7 5.00 64.3 42.7 5.10 56.7 56.7 5.21 59.7 55.3 5.37 62.1 41.6 5.47
90
62.9 62.9 4.42 64.9 61.9 4.56 66.2 51.0 4.65 60.6 60.6 4.87 62.6 62.6 5.02 63.9 52.0 5.11 58.5 58.5 5.23 60.4 60.4 5.39 61.7 50.6 5.49
75
56.9 50.3 4.42 62.9 38.1 4.56 67.7 16.8 4.64 54.9 51.2 4.86 60.7 38.8 5.01 65.3 17.1 5.11 53.0 49.9 5.22 58.6 37.8 5.38 63.0 16.7 5.48
80
59.4 57.7 4.43 64.1 47.7 4.57 67.7 31.2 4.66 57.3 57.3 4.87 61.8 48.6 5.03 65.3 31.8 5.12 55.3 55.3 5.23 59.7 47.4 5.40 63.0 31.0 5.50
85
61.6 61.6 4.45 65.0 57.4 4.59 67.5 43.2 4.67 59.5 59.5 4.89 62.7 58.5 5.04 65.1 44.0 5.14 57.4 57.4 5.25 60.5 57.0 5.41 62.9 42.9 5.51
90
63.7 63.7 4.46 65.7 63.8 4.60 67.1 52.6 4.68 61.4 61.4 4.90 63.4 63.4 5.06 64.7 53.6 5.15 59.3 59.3 5.26 61.2 61.2 5.43 62.5 52.2 5.53
115 61
DB(̧ ) TGC
1710
73
75
Outdoor DB(̧ ) Indoor WB(̧ )
1520
67
105
67 73 DB(̧ ) TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI
1520
CFM
Gross Cooling Capacity (MBH) 5RT TN-C0608SA0(English)
125
67
73
67
61
73
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
75
45.2
39.3
5.36
50.0
29.7
5.53
53.7
13.1
5.63
41.9
37.5
5.61
46.3
28.4
5.79
49.8
12.5
5.89
80
47.2
45.1
5.38
50.9
37.3
5.55
53.7
24.4
5.65
43.7
43.0
5.63
47.1
35.6
5.80
49.8
23.3
5.91
85
48.9
48.9
5.39
51.6
44.9
5.56
53.6
33.7
5.67
45.3
45.3
5.64
47.8
42.8
5.82
49.6
32.2
5.93
90
50.5
50.5
5.41
52.2
49.8
5.58
53.3
41.1
5.69
46.8
46.8
5.66
48.3
47.6
5.84
49.3
39.2
5.95
75
47.3
41.9
5.40
52.3
31.7
5.57
56.2
14.0
5.67
43.8
40.0
5.65
48.4
30.3
5.82
52.1
13.4
5.93
80
49.3
48.1
5.42
53.2
39.7
5.59
56.2
26.0
5.69
45.7
45.7
5.66
49.3
37.9
5.84
52.1
24.8
5.95
85
51.2
51.2
5.43
54.0
47.9
5.60
56.1
36.0
5.71
47.4
47.4
5.68
50.0
45.7
5.86
52.0
34.4
5.97
90
52.9
52.9
5.45
54.6
53.2
5.62
55.7
43.8
5.72
49.0
49.0
5.70
50.6
50.6
5.88
51.6
41.8
5.99
75
48.6
45.0
5.44
53.7
34.1
5.61
57.7
15.0
5.71
45.0
42.9
5.68
49.7
32.5
5.86
53.5
14.4
5.97
80
50.7
50.7
5.45
54.6
42.7
5.62
57.7
28.0
5.73
46.9
46.9
5.70
50.6
40.7
5.88
53.5
26.7
5.99
85
52.6
52.6
5.47
55.4
51.4
5.64
57.6
38.7
5.75
48.7
48.7
5.72
51.3
49.1
5.90
53.3
36.9
6.01
90
54.3
54.3
5.49
56.0
56.0
5.66
57.2
47.1
5.76
50.3
50.3
5.73
51.9
51.9
5.92
53.0
44.9
6.03
75
49.4
47.1
5.47
54.6
35.7
5.65
58.7
15.7
5.75
45.7
45.0
5.72
50.6
34.1
5.90
54.4
15.0
6.01
80
51.5
51.5
5.49
55.6
44.7
5.66
58.7
29.3
5.77
47.7
47.7
5.74
51.5
42.6
5.92
54.4
27.9
6.03
85
53.5
53.5
5.51
56.4
53.8
5.68
58.6
40.5
5.79
49.5
49.5
5.75
52.2
51.4
5.94
54.2
38.6
6.05
90
55.2
55.2
5.52
57.0
57.0
5.70
58.2
49.3
5.80
51.1
51.1
5.77
52.8
52.8
5.95
53.9
47.0
6.06
75
50.0
48.6
5.51
55.3
36.8
5.68
59.5
16.2
5.79
46.3
46.3
5.76
51.2
35.1
5.94
55.1
15.5
6.05
80
52.2
52.2
5.53
56.3
46.1
5.70
59.5
30.2
5.81
48.3
48.3
5.77
52.1
44.0
5.96
55.1
28.8
6.07
85
54.2
54.2
5.54
57.1
55.5
5.72
59.3
41.8
5.82
50.2
50.2
5.79
52.9
52.9
5.97
54.9
39.8
6.09
90
55.9
55.9
5.56
57.7
57.7
5.74
59.0
50.8
5.84
51.8
51.8
5.81
53.5
53.5
5.99
54.6
48.5
6.10
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1 000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1 000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
1-24
Ducted Split
3~5RT
TA5CUN2-01A
7DEOH &)0
Performance Data
(YDSRUDWRU )DQ 3HUIRUPDQFH 'DWD 57 (QJOLVK
+LJK 6SHHG (63 LQ $T
%+3
‡ 0RWRU KHDW 0%+ [ )DQ %+3 ‡ 7HVW &RQGLWLRQ 9ROWDJH 9 2SHUDWLQJ 0RGH )DQ RSHUDWLRQ PRGH ZLWK FOHDQ ILOWHU GU\ FRLO ZLWKRXW HOHFWULF KHDWHU ‡ 'R QRW RSHUDWH WKH XQLW DW D FRROLQJ DLUIORZ WKDW LV OHVV WKHQ FIP 0%+ ‡ &)0 RI FRROLQJ FDSDFLW\ WHVW FIP DW LQ $T
7DEOH O V
(YDSRUDWRU )DQ 3HUIRUPDQFH 'DWD 57 6,
+LJK 6SHHG (63 PP $T
%.:
‡ )DQ PRWRU KHDW NZ [ )DQ %NZ ‡ 7HVW &RQGLWLRQ 9ROWDJH 9 2SHUDWLQJ 0RGH )DQ RSHUDWLRQ PRGH ZLWK FOHDQ ILOWHU GU\ FRLO ZLWKRXW HOHFWULF KHDWHU ‡ 'R QRW RSHUDWH WKH XQLW DW D FRROLQJ DLUIORZ WKDW LV OHVV WKHQ O V N: ‡ O V RI FRROLQJ FDSDFLW\ WHVW O V DW PP$T
3~5RT
Ducted Split
1-25
Performance Data
TA5CUN2-01A
7DEOH &)0
(YDSRUDWRU )DQ 3HUIRUPDQFH 'DWD 57 (QJOLVK
+LJK 6SHHG (63 LQ $T
%+3
‡ 0RWRU KHDW 0%+ [ )DQ %+3 ‡ 7HVW &RQGLWLRQ 9ROWDJH 9 2SHUDWLQJ 0RGH )DQ RSHUDWLRQ PRGH ZLWK FOHDQ ILOWHU GU\ FRLO ZLWKRXW HOHFWULF KHDWHU ‡ 'R QRW RSHUDWH WKH XQLW DW D FRROLQJ DLUIORZ WKDW LV OHVV WKHQ FIP 0%+ ‡ &)0 RI FRROLQJ FDSDFLW\ WHVW FIP DW LQ $T
7DEOH O V
(YDSRUDWRU )DQ 3HUIRUPDQFH 'DWD 57 6,
+LJK 6SHHG (63 PP $T
%NZ
‡ )DQ PRWRU KHDW NZ [ )DQ %NZ ‡ 7HVW &RQGLWLRQ
9ROWDJH 9 2SHUDWLQJ 0RGH )DQ RSHUDWLRQ PRGH ZLWK FOHDQ ILOWHU GU\ FRLO ZLWKRXW HOHFWULF KHDWHU ‡ 'R QRW RSHUDWH WKH XQLW DW D FRROLQJ DLUIORZ WKDW LV OHVV WKHQ O V N: ‡ O V RI FRROLQJ FDSDFLW\ WHVW O V DW PP$T
1-26
Ducted Split
3~5RT
Performance Data
TA5CUN2-01A
Evaporator Fan Performance Data 5RT (English )
Table-11 CFM 1 650 1 700 1 800 1 900 1 950 2 000
High Speed ESP(in. Aq.) BHP 0.52 0.53 0.41 0.56 0.31 0.58 0.20 0.60 0.10 0.62 0.04 0.63
• Motor heat (MBH)=5.09 x Fan BHP • Test Condition: Voltage : 240V, Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater. • Do not operate the unit at a cooling airflow that is less then 300cfm/12MBH. • CFM of cooling capacity test : 1 900 CFM at 0.20 in Aq.
Evaporator Fan Performance Data 5RT (SI)
Table-12 l/s
High Speed BKW ESP(mm Aq.)
778
13.24
0.40
802
10.52
0.42
849
7.80
0.43
896
5.08
0.45
920
2.36
0.46
943
1.00
0.47
• Fan motor heat(kw)=2 x Fan Bkw • Test Condition:
Voltage : 240V, Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater. • Do not operate the unit at a cooling airflow that is less then 142 (l/s)/ 3.5 (kW). • l/s of cooling capacity test :896 l/s at 5.08 mmAq.
3~5RT
Ducted Split
1-27
TA5CUN2-01A
Performance Data
Table-13
Accessory Static Pressure Drops
CFM
MODEL
Standard Filter
l/s
Electric Heater 5kW
9kW
in.Aq. mm Aq. in.Aq. mm Aq. in.Aq. mm Aq. 880 415 1 100 519 1 320 623 1 120 529 1 650 779 1 815 856 1 440 680 1 800 849 2 160 1 019
TN-C0368SA0 TN-C0488SA0
TN-C0608SA0
Table-14 MODEL
0.02 0.03 0.03 0.03 0.03 0.05 0.03 0.05 0.07
0.51 0.76 0.76 0.76 0.76 1.27 0.76 1.27 1.78
Input(kW)
TN-C0488SA0 TN-C0608SA0
0.25 0.25 0.51 0.25 0.51 0.76 0.51 0.51 1.02
0.01 0.01 0.02 0.01 0.02 0.04 0.02 0.04 0.05
0.25 0.25 0.51 0.25 0.51 1.02 0.51 1.02 1.27
Electric Heating Capacity Total
TN-C0368SA0
0.01 0.01 0.02 0.01 0.02 0.03 0.02 0.02 0.04
Output(MBH)
No. of Stages
Stage1 Stage2 Input(kW) Output(MBH) Input(kW) Output(MBH)
5 9 5 9
17.07 30.72 17.07 30.72
1 1 1 1
5 9 5 9
17.07 30.72 17.07 30.72
-
-
5 9
17.07 30.72
1 1
5 9
17.07 30.72
-
-
Note: 1. The output ratings shown above is at 415V. For other voltage, Output = Capacity Multiplier x Rated Output 2. E/heater Voltage range is 380~415V.
Table-15
Voltage 380 400 415
Capacity Multiplier 0.84 0.92 1.00
Air Temperature Rise Across Electric Heater(°F)
Capacity
Stage
3RT (1150CFM)
4RT (1800CFM)
5RT (1900CFM)
5kW 9kW
1 1
14.4 25.8
9.6 17.2
8.8 15.8
(kW x 3413) (1.08 x CFM) • If you want to take temp rise at different airflow use above equation.
• Temp. Rise across Electric Heater =
1-28
Ducted Split
3~5RT
TA5CUN2-01A
Electrical Data
11. Electrical Data Electrical Requirements Electrical Data, Cooling
Tab le-16 MODEL
Unit Operating Voltage Range
TN-C0368SA0 TN-C0488SA0 TN-C0608SA0
342-456 342-456 342-456
Standard indoor fan motor *M.C.A. *M.F.S. *M.C.B 20 20 9.7 25 25 13.9 30 30 16.5
Note: *M.C.A.: Minimum Circuit Ampacity *M.F.S.: Maximum Fuse Size *M.C.B.: Maximum Circuit Breaker
Tab le-17 MODEL TN-C0368SA0 TN-C0488SA0 TN-C0608SA0
Electric Data with Electric Heating Standard indoor fan motor HEATER HEATER POWER SUPPLY MODEL NO. CAPACITY(kW) *M.C.A. *M.F.S. *M.C.B 5 ANEH0581A 18.8 25 25 3Ø, 380/415V 9 ANEH0981A 24.9 35 35 25 5 25 ANEH0581A 19.1 3Ø, 380/415V 25.2 35 35 ANEH0981A 9 ANEH0581A 21 25 25 5 3Ø, 380/415V 28 35 35 ANEH0981A 9
Note: Ɣ The heater Capacity shown above is at 415V. Ɣ Voltage range is 342-456V. *M.C.A.: Minimum Circuit Ampacity *M.F.S.: Maximum Fuse Size *M.C.B.: Maximum Circuit Breaker * : The values depend on the model.
3~5RT
Ducted Split
1-29
TA5CUN2-01A
Electrical Data
7DEOH
(OHFWULFDO &KDUDFWHULVWLFV (YDSRUDWRU )DQ 0RWRU +] 6WDQGDUG LQGRRU IDQ PRWRU
02'(/
1R
9ROWV
3KDVH
+3
)/$
57
57
57
7DEOH 02'(/
(OHFWULFDO &KDUDFWHULVWLFV &RPSUHVVRU DQG 2XWGRRU )DQ 0RWRU +] &2035(6625 )/$ 3KDVH +3
287'225 )$1 02725 +3 )/$ 3KDVH 9ROWV
/5$
1R
1R
9ROWV
57
57
57
1RWH ‡ )/$ )XOO /RDG $PSV ‡ /5$ /RFNHG 5RWRU $PSV
1-30
Ducted Split
3~5RT
Temperature,Pressure Chart
TA5CUN2-01A
7HPSHUDWXUH 3UHVVXUH &KDUW 0RGHO 1R 71 & 6$ &
/RZ 3UHVVXUH .J FP
'LVFKDUJH $LU 7HPS '% &
&
NJ FP
2XWGRRU 7HPS '% &
'LVFKDUJH $LU 7HPSHUDWXUH & /RZ 3UHVVXUH .J FP
0RGHO 1R 71 & 6$ &
/RZ 3UHVVXUH .J FP
'LVFKDUJH $LU 7HPS '% &
&
NJ FP
2XWGRRU 7HPS '% &
'LVFKDUJH $LU 7HPSHUDWXUH & /RZ 3UHVVXUH .J FP
1RWH 'LVFKDUJH $LU 7HPSHUDWXUH LV DW ,QGRRU WHPSHUDWXUH & '% & :%
3~5RT
Ducted Split
1-31
Temperature,Pressure Chart
TA5CUN2-01A
0RGHO 1R 71 & 6$ &
/RZ 3UHVVXUH .J FP
'LVFKDUJH $LU 7HPS '% &
&
NJ FP
2XWGRRU 7HPS '% &
'LVFKDUJH $LU 7HPSHUDWXUH & /RZ 3UHVVXUH .J FP
1RWH 'LVFKDUJH $LU 7HPSHUDWXUH LV DW ,QGRRU WHPSHUDWXUH & '% & :%
1-32
Ducted Split
3~5RT
TA5CUN2-01A
Refrigerant Cycle Diagrams
13. Refrigerant Cycle Diagrams Model No.: TN-C0368SA0, TN-C0488SA0, TN-C0608SA0 CAPILLARY TUBE
SERVICE VALVE
INDOOR COIL
OUTDOOR COIL BY-PASS HI-PRESSURE SWITCH
SERVICE VALVE
COMPRESSOR Note: : Cooling
3~5RT
Ducted Split
1-33
Operation Range
TA5CUN2-01A
14. Operation Range Cooling
Outdoor Unit [°C DB]
54
Continuous operation
21
18
32 Indoor Unit [°C DB]
• Although low ambient kit is installed, in case outdoor temperature goes below 0°C, the cooling capacity can be dropped and operation characteristics can be slightly different.
1-34
Ducted Split
3~5RT
Operating Space Limitations
TA5CUN2-01A
15. Operating Space Limitations Indoor unit Model : TNNC0368SA0 , TNNC0488SA0 , TNNC0608SA0 Clearance 12"(300mm) Clearance 12"(300mm)
Clearance 36" (910mm)
Clearance 12" (300mm)
Clearanc
14"(360mm) Clearance 14" Ground
Outdoor Unit
Model : TNUC0488SA0 , TNUC0608SA0
Model : TNUC0368SA0
CLEARANCE 12"(300mm)
CLEARANCE 28" (910mm)
3~5RT
CLEARANCE 12"(300mm)
CLEARANCE 20"(510mm)
CLEARANCE 20"(510mm)
CLEARANCE 20"(510mm)
Ducted Split
CLEARANCE 20"(510mm)
CLEARANCE 20"(510mm)
1-35
Coefficient of Capacity Change
TA5CUN2-01A
16. The Coefficient of Capacity Change 100
Cap ac i t y (%)
3 RT(25m)
4/5RT(30m)
90
80
70 7.5
10
20
25
30
Total pipe length(m)
Model
Pipe Size Diameter:Ø mm(inch) Gas
Liquid
Length(m)
Elevation(m)
Additional refrigerant
Standard
Max.
Standard
Max.
(g/m)
3 RT
15.88(5/8) 9.52(3/8)
7.5
25
7.5
15
60
4 RT
19.05(3/4) 9.52(3/8)
7.5
30
7.5
20
80
5 RT
19.05(3/4) 12.7(1/2)
7.5
30
7.5
20
110
Ɣ If 4RT Model is installed at a distance of 15m, 600g of refrigerant should be added (15-7.5) x 80g=600g Ɣ Capacity is based of standard length and maximum allowance length is on the basis of reliability.
Notes: * Equivalent pipe length= Actual pipe length + number of bend x 0.3
1-36
Ducted Split
3~5RT
TA5CUN2-01A
Mechanical Specifications
17. Mechanical Specifications Mec hanical Specifications General Air handling units shall be completely factory asembled including coil drain pan, Blower motor and controls in an insulated casing that can be applied in horizontal or vertical configuration. Units shall be rated in accordance with ARI standard testing procedure, fully changed with R22. Units shall fully factory tested before shipment.
Casing Unit casing shall be constructed of having gauge zinc coated, galvanized steel. The cabinet shall be exterior painted and weather resistance. The condensing units shall have a water and air tight service panels with minimum number of screws per panel for easy servicing.
Compressors LG Ducted Split System units shall have direct drive hermetic compressor, reciprocating type with internal built in lubricating mechanism for all moving parts. Motor shall be suction gas cooled with internal temperature and over current sensitive motor over load, for maximum protection. Factory rubber shock mounted and internally spring isolation for sound and vibration control.
Refrigerant Circuits Each refrigerant circuit shall have an independent fixed capillary tube devices and service pressure ports, and refrigerant line filter(factory-installed) as standard.
Ev aporator and Condenser Coils Shall be aluminum plate fins, mechanically bonded to copper tubes. Coil shall be factory tested for leakage and pressure.
Outdoor Fans Statically and dynamically, direct drive outdoor fan in Horizontal discharge position. Permanently lubricated fan motors with built in thermal overload protection.
Indoor Fan Direct drive indoor fan for 3, 4, 5 RT units with forward curve centrifugal fans.All motors shall be thermally overload protected.
Controls All units shall be controlled by thermostat. Time delay PCB shall provide time delay between Fan and Compressor.
3~5RT
Ducted Split
1-37
Appendix
TA5CUN2-01A
$SSHQGL[ 8QLW &RQYHUVLRQ &RROLQJ &DSDFLW\ 57
%WX K
NFDO K
:
9ROXPH &00
&)0
O V
/HQJWK P
FP
PP
LQFK
3RZHU +3
:
N:
7HPSHUDWXUH & )
:KHUH & LV 7HPSHUDWXUH LQ & ) LV 7HPSHUDWXUH LQ )
1-38
Ducted Split
3~5RT
TA5CUN2-01A
3~5RT
Ducted Split
1-39
Part 2 7.5~12.5RT
1. Models List ......................................................................................................................2-2 2. Model Number Nomenclature ..........................................................................................2-3 3. Feature & Benefits ...........................................................................................................2-4 4. List of Functions ...............................................................................................................2-8 5. Specifications ................................................................................................................. 2-9 6. Dimensional Drawings ...................................................................................................2-11 7. Type of Applications .......................................................................................................2-14 8. Wiring Diagrams.............................................................................................................2-15 9. Performance Data ........................................................................................... .............2-18 10. Electrical Data ..............................................................................................................2-30 11. Temperature, Pressure Chart.......................................................................................2-31 12. Refrigerant Cycle Diagrams .........................................................................................2-33 13. Operation Range..........................................................................................................2-34 14. Operating Space Limitations ........................................................................................2-35 15. The coefficient of Capacity Change .............................................................................2-36 .. .......................................................................................2-37 16. Mechanical Specifications .. .......................................................................................2-38 17. Function of Remote control
7.5-12.5RT
Ducted Split
2-1
TA5CUN2-01A
Models List
1. Models List 1.1 Cooling Only Nominal Capacity RT
Refrigerant
7.5 10 12.5
2-2
Power Supply
Model Model Name
Ø, V, Hz
TN-C0908T00 R22
TN-C1208T00
3Ø, 380-415V, 50Hz
TN-C1508T00
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Model Number Nomenclature
2. Model Number Nomenclature T N - C 0 9
0 8 T 0 0
Development Sequence Model Type 0:Gold Fin(Over 5RT) B: Basic
Outdoor Fan Discharge S: Side Discharge T: Top Discharge Electric Standard (Volts / Freq. / Phase) 8 : 380-415V / 50Hz / 3Ă˜ Cooling Capacity 090 : 78 000 Btu/h 150 : 132 000 Btu/h
120 : 108 000 Btu/h
Model Type C: Cooling Only H: Heat Pump
Type of Air Conditioner TN: LGETA Ducted Split Air Conditioner
7.5-12.5RT
Ducted Split
2-3
TA5CUN2-01A
Features & Benefits
3. Features & Benefits (7.5RT, 10 RT 12.5RT )
This range of LG units are suitable for high static requirement s used for light commercial & commercial application. The Units are completely assembled, piped and wired in the factory. The indoor and outdoor units are separately packed & shipped. Each unit has been tested for pressure and has a holding charge of R22 for storage and for shipping. The compact design, quiet operation and higher cooling capacity makes the condensing units suitable for any outdoor location. Light Weight air-handlers make them suitable for ceiling application. All shipped metal parts are made of commercial grade galvanized steel. After fabrication, each part is cleaned & coated with baked enamel paint. A complete line of high static blower units are available for precise capacity of application. All indoor units are equipped with micro-processor controlled wired remote controller.
Easy installation LG ducted split units provide many time and money saving features. Micom Control Time delay relay, anti-short-cycle timer no more required with micom control. Initial cost saving, since the functions of these parts are the main feature of micom control.
Easy access remote controller Remote controller has 3 wires only. This is another cost and time saving installation feature. The wiring of low voltage to the unit and remote controller is easy as brown-brown, red-red, yellow-yellow connections. This simplified system makes it easier for the installer to attach.
Compact and light weight design
2-4
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Features & Benefits
Durable, dependable components Waterproof cabinets are constructed of galvanized steel with powder coated painting. Compact size enables the unit to be located where space is limited. Condenser fin guard is designed for safety against sharp edge of outdoor coil. Micom Control - Reduce the number of components to operate the unit . - Component failure is reduced. - Cooling mode controlled by Micom control through input signal from indoor and outdoor temperature sensor. - Field installed anti short cycle timer and time delay relay not required with micom control. - Humidifier can be controlled by micom control.
Tight Top Cover and Cabinet - The units incorporate two or three layers top cover. The two or three piece layers overlaps in such a way that water cannot leak into the unit. These overlapped edges are gasketed and sealed to ensure superior water integrity.
Micom Control • Gradual power supply for fans, compressor and heater by staging through micom control. • In case of power failure, Micom control remembers the previous running condition before power failure. The unit will start again in previous mode when power re-energized.
Product quality and reliability • LG Ducted split unit have been rigorously life tested at the factory for more than 1 500 hours. • All of LG Outdoor units were rigorously rain tested at the factory to ensure water tight integrity. • Actual shipping tests are performed to determine the best packing. Units are shipped around the country to obtain the best packaging test result. These test assure that the unit will arrive at your job site in best condition. • We perform 100% coil leak test at the factory. The indoor coil and outdoor coils are leak tested at 200psig and pressure tested to 500psig respectively. • Every unit goes full run test to meet LG standards requirements. • Before units are shipped, 5 units which are selected by sampling undergo STLT(Short Time Life Test) are for more than 300 hours. • All LG Ducted split units undergo overload cooling tested(ambient temp is 129°F). In this condition, units operated continuously without any problem.
7.5-12.5RT
Ducted Split
2-5
Features & Benefits
TA5CUN2-01A
Basic & Optional Features Cooling & Fan Operation : - LG ducted split air conditioners can provide cooling & fan operation. In the cooling mode, it cools the air with an operation range of 18~30°C. In the fan operation mode, only indoor fan at the selected speed will run, outdoor fan and compressor will be off.
Self Diagnosis Function: - This function provides diagnosis of the unit. An error code will be displayed on the LCD wired remote controller & diagnosis can be done as per the code indication. The same is also printed on key cover of the LCD wired remote controller.
Gold Fin TM Anti Corrosion [Salt spray test for 15 days]
- LG’s Outdoor Heat Exchanger is coated with a golden anti-corrosive epoxy treatment on the aluminum coil to minimized corrosion. This maintains heat transfer pro-
After 15 days
LG Gold Fin ™ Anti Corrosion
After 15 days
Conventional starting to corrode
perties of the coil for an extended time where as nonGold Fin coils progressively lose efficiency due to sur-
Gold fin
face corrosion. Standard on every LG air conditioner, This assists in areas suffering from pollution or near the ocean where the unit may subjected to higher levels of salt. Uncoated aluminum
Wired Remote Control: - It can control all the functions of the unit. You can check/set temperature, set timer, holiday & also diagnose the error of the unit. It also has the option of weekly program.
Weekly Program: -It provides on/off schedule of operation for a period of one week.
Time Delay Safety Function: -It delays restarting of the compressor by three minutes preventing any damage to the compressor.
2-6
Ducted Split
7.5-12.5RT
Features & Benefits
TA5CUN2-01A
Child Lock Function: -It prevents the children or others from tampering with the control buttons. Unit can be controlled by the wireless remote controller. This can be easily set by pressing timer key & Min key simultaneously. After
CHILD LOCK -Display
child lock is set, pressing any key will display CL on the LCD for 3 seconds and all the keys are ineffec1
tive.
Product Data 16
2
Group Control: ........
- It enables to control up to 16 units with the help of one wired remote controller. All the units will follow same
AUTO SWING
OPERATION
setting of temperature & other sub functions.
FAN SPEED
SET TEMP Room Temp
2ndF Timer
HI MED LO
Time
ZONE
SUB FUNCTION
AUTO Heater Preheat JET Defrost Humidify SLo Filter Out door 1 2 3 4
Operation unit No Func Program set
On Off Set no. Time 01
03
05
07
09
11
13
15
17
19
21
23
Main PCB
Central Control: (Accessory) -It enables to control 16 x 8 = 128 unit with the help of 8 controllers. All units can be put on and off from
M 1
M 2
M 16
M 17
M 18
M 128
T/B 1
T/B 2
T/B 16
T/B 17
T/B 18
T/B 128
one Central Room. For Setting Temperature, Fan speed and other sub functions, access the LCD wired remote controller of each unit.
Controller #1
Controller #2
Controller #8 (T/B: Terminal Block)
Wireless Remote Control: (Accessory) - It provides ease of control.
Electric Heater: (Accessory) - Electric Heater can be used to provide heat in addition to cycle heat. It also provides quick heating. It can also work as a stand alone heater with only fan operation.
7.5-12.5RT
Ducted Split
2-7
List of Functions
TA5CUN2-01A
4. List of Functions Model No. Features
Notes: O :Applied
TN-C0908T00 TN-C1208T00 TN-C1508T00
Cooling & Fan Operation
O
O
O
Auto Restart Operation
O
O
-
Wired Remote Control
O
O
O
Group Control
O
O
-
Child Lock Function
O
O
-
Self Diagnosis Function
O
O
-
W eekly Program
O
O
-
Time Delay Relay
O
O
O
Two Thermistor Control
-
-
-
Central Control
-
-
-
Zone Control
-
-
-
Energy Saving Gold Fin
Optional
Optional
-
W ireless Remote Control
Accessory
Accessory
-
Electric Heater
Accessory
Accessory
Accessory
Fire Alarm Function
-
-
-
Electronic Thermostat
-
-
-
Low Pressure Switch
-
-
O
High Pressure Switch
O
O
O
Phase Protection
O
O
O
- :Not applied
Ă— :No relation
* Option : Model name & price are different according to options, and assembled in factory with main unit. * Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
2-8
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Specifications
5. Specifications Nominal RT
(RT )
Models Gross Cooling Capacity Capacity
Net Cooling Capacity Net Heating Capacity Power Supply
Electrical Data
M.C.A(with Standard Motor) Power Input
Performance
Air Circulation(Nominal) EER SEER COP Sound Rating
Indoor Coil
Indoor Fan
Cooling Heating Cooling Heating
No.of cycle Type Tube Size(O.D) Rows / Column / FPI Length Face Area Type * No. Used Diameter W idth Drive Type / Motor Step No. Motors Motor Output(Standard / Oversized) Motor RPM(Standard
Indoor Outdoor
kW Btu/h kW Btu/h kW Btu/h Ø / V / Hz A A W W cfm Btu/h.W Btu/h.W W /W bell bell
mm(inch) mm(inch) (sq.ft) mm(inch) mm(inch) Hp
No. of Outdoor Units
Compressor
Outdoor Coil
Outdoor Fan
Service Valve Connecting Tube
Type * Quantity Model Maker Capacity Motor Type Motor Input Oil Type Oil Charge Type Tube Size(O.D) Rows / Column / FPI Length Face Area Type * No. Used No. Used/Diameter Drive Type Air Circulation No. Motot / Motor Output(Hp) Motor RPM Liquid Gas Liquid Gas Length(Standard)
Dehumidification Rate Drain Connection Size(inch) Refrigerant
Refrigerant Charge
Refrigerant Control Additional Refrigerant Charge Operation Range Cooling Heating (Outdoor) Indoor Unit (W * H * D) Dimensions Outdoor Unit or Unitary (W * H * D) Net Weight Fliter Stuffing Quantity
Indoor Unit Outdoor Unit or Unitary Size * No. Used Filter Rack Thickness W ithout S/Parts
Btu/h W cc mm(inch) mm(inch) (sq.ft) EA(inch) cfm Hp mm(inch) mm(inch) mm(inch) mm(inch) m(inch) kg/h kg(lbs) Type g/m o
C C mm inch mm inch kg(lbs) kg(lbs) o
mm(inch) (20ft / 40ft / 40Hi
Note : 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27.0 (80.6°F ) DB/19.0 (66.2°F) WB - Outdoor Temperature 35 (95°F) DB/24 (75.2°F) WB Piping Length - Interconnecting Piping Length 7.5m '- Level Difference of Zero 2. Nominal CFM : Fan operation mode with clean filter, dry coil. 3. The specification may be subject to change without prior notice for purpose of improvement.
7.5-12.5RT
Ducted Split
7.5 TN-C0908T00 23.7 80 900 22.9 78 000 3/380 - 415/50 20 8 600 2 800 9.6 6.5 6.1 2 High efficiency 9.52(3/8) 2R / 24C / 17FPI 1 400(55 1/8) 0.85(9.19) Centrifugal Blower * 1 323(12 11/16) 381(15) Pulley / 1 1 1.0 /2.0 980 1 Scroll * 2 C-SB303H8A SANYO 40 262 Three Phase 3 650 SAY56T 1 700 High efficiency 7(9/32) 2R / 36C / 17FPI 700(27.6) 1.55(16.7) Propeller * 1 1EA(20 23/32) Direct 4,300 1EA / 0.17 850 12.7(1/2) 19.05(3/4) 12.7(1/2) 19.05(3/4) 7.5 (295 9/32) 5.2 1 1/4 2.8*2(6.17*2) R22 Capillary Tube 60 21~54 16 00 * 660 * 798 63 *26 * 31 3/8 806 * 1555 * 690 31 11/16*61 7/32*27 5/32 190(418) 140(308) 6/15/22
10 TN-C1208T00 32.6 111 200 31.7 108 000 3/380 415/50 30 12 500 3 600 9.2 6.7 6.2 2 High efficiency 9.52(3/8) 3R / 24C / 17FPI 1 400(55 1/8) 0.85(9.19) Centrifugal Blower * 1 323(12 11/16) 381(15) Pulley / 1 1 2.0 /3.0 1,460 1 Scroll * 2 C-SBX215H38N SANYO 61 075 Three Phase 5 380 SAY56T 1 700 High efficiency 7(9/32) 2R / 36C / 17FPI 1 170(46.1) 1.55(16.7) Propeller * 2 2EA(20 23/32) Direct 4,300 2EA / 0.17 850 12.7(1/2) 19.05(3/4) 12.7(1/2) 19.05(3/4) 7.5(295 9/32) 6.8 1 1/4 2.95*2(6.5*2) R22 Capillary Tube 60 21~54 16 00 * 660 * 798 63 *26 * 31 3/8 1280 * 1555 * 690 50 13/32*61 7/32*27 5/32 190(418) 280(616) 6/15/19
Conversion Formula kcal/h = kW x 860 Btu/h = kW x 3412 cfm = m 3 /min x 35.3
2-9
TA5CUN2-01A
Specifications Nominal RT
(RT )
12. 5
Models
TN-C1508T00
Gross Cooling Capacity Capacity
Net Cooling Capacity Net Heating Capacity
Electrical Data
Power Input
kW
38.7
Btu/h
132,000
kW
-
Ø / V / Hz Cooling
3/380
A A
-
Cooling
W
13,800
Heati n g
W
-
CFM
4 ,400
EER
Btu/h.W
9 .57
SEER
Btu/h.W
-
W /W
-
COP Sound Rating
bell
6.3
Type Tube Size(O.D) Evaporator
High efficiency mm(inch)
9.52(3/8)
Rows / Column / FPI Length Face Area
3R / 24C /17FPI mm(inch)
1,400 55 1/8 0.85(9.19)
(sq.ft)
Type * No. Used Indoor Fan
Centrifugal Blower
Diameter
mm(inch)
Width
mm(inch)
323(12 11/16) 381(15)
Maker
WEITELI
Drive Type / Motor Step No. Motors Motor Output(Standard / Oversized) Motor RPM(Standard / Oversized) No. of Outdoor Units
Belt/1 1
Indoor Motor
Hp
2.0/3.0 1460/1470 1
Type * Quantity
Scroll*2
Model
SR081Y LG
Maker Capacity Compressor
Btu/h
16,121
Motor Type Motor Input
Three Phase W
5 ,9 8 1
Oil Type Oil Charge
SUNISO 4GSI cc
2,325
Type Tube Size(O.D) Condenser
High efficiency mm(inch)
9.52('3/8)
Rows / Column / FPI Length Face Area
Outdoor Fan
3R / 40C /17FPI 2200('86 5/8)
mm(inch)
2.24(24.1)
(sq.ft)
Type * No. Used Diameter
Propeller * 1 inch
-
Maker
-
Drive Type Outdoor Motor
Air Circulation No. Motor / Motor Output(Hp)
Direct CFM
8 200
Hp
1E A / 1.5
mm(inch)
15.88(5 / 8)
Motor RPM Service Valve
Connecting Pipe
Liquid
950
Gas
mm(inch)
28(1 1/8)
Liquid
mm(inch)
15.88(5 / 8)
Gas
m m (i n c h )
28(1 1/8) 7.5 (2 95 9/32 )
Length(Standard) Dehumidification Rate
m(inch)
11.6
/h
Drain Connection Size(inch)
1 1/4 kg
Refrigerant
Refrigerant Charge
13.5
lbs
30
Type
R22
mm
Capillary Tube 1 700 * 7 20 * 800
i nc h
6 6 1 5/ 1 6 *2 8 5 / 16 *3 1 7/ 1 6
Refrigerant Control Indoor Unit (W * H * D) Dimensions
Net Weight Fliter Stuffing Quantity
Outdoor Unit or S/Package (W * H * D)
mm
11 3 0 * 11 8 0 * 1 10 0
inch
44 7/16*46 15/32*43 5/16
Indoor Unit
kg(lbs)
1 9 0 (4 1 8 )
Outdoor Unit or S/Package
k g ( lb s )
2 50 ( 5 50 )
Size * No. Used Filter Rack Thickness
inch
8 / 18 / 20
Without S/Parts(20ft / 40ft / 40ft HI)
Note : 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27.0 (80.6°F ) DB/19.0 (66.2°F) WB - Outdoor Temperature 35 (95°F) DB/24 (75.2°F) WB Piping Length - Interconnecting Piping Length 7.5m '- Level Difference of Zero 2. Nominal CFM : Fan operation mode with clean filter, dry coil. 3. The specification may be subject to change without prior notice for purpose of improvement.
2-10
415/50 35
Heati n g
Air Circulation(Nominal) Performance
39.6 135,200
Btu/h
Power Supply M.C.A (with Standard Motor)
kW Btu/h
Ducted Split
Conversion Formula kcal/h = kW x 860 Btu/h = kW x 3412 cfm = m 3 /min x 35.3
7.5-12.5RT
TA5CUN2-01A
Dimensional Drawings
6. Dimensional Drawings Model No.: TN-C0908T00 1. Indoor units
63
.0
16
26.0
660
00
8
.4
79
31
(Unit : inch(mm))
61.2(1555)
2. Oudoor units
)
31.7(
806)
90
6 .2( 7 2
(Unit : inch(mm))
7.5-12.5RT
Ducted Split
2-11
TA5CUN2-01A
Dimensional Drawings
Model No.: TN-C1208T00 1. Indoor units
63
.0
16
26.0
660
00
8
.4 31
79
(Unit : inch(mm))
61.2(1555) .
2. Oudoor units
50.4(
0)
69
1280
)
( 7.2
2
(Unit : inch(mm))
2-12
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Dimensional Drawings
Model No.: TN-C1508T00 1. Indoor units
66
.94
17
28.35 720
00
0
.5
80
31
(Unit : inch(mm))
2. Oudoor units
0.79(20)
1.58(40)
1.61(41)
46.46(1180)
70)
6(8
2 34. 3.15(80) 3.94(100) 4.13(105)
1.77(45) 10.67(271)
44.4
)
9(11
30)
14.6
0 110
31(
1(37
1)
43.
(Unit : inch(mm))
7.5-12.5RT
Ducted Split
2-13
TA5CUN2-01A
Type of Applications
7\SH RI $SSOLFDWLRQ 2QH 8QLW $SSOLDQFH
2-14
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Wiring Diagrams
Indoor wiring Diagrams
To Outdoor Unit
Notes BK BR YL
BLACK BROWN YELLOW
OR RD BL
ORANGE RED BLUE
WH WHITE GN/YL GREEN/YELLOW
Factory wiring Field wiring
Outdoor wiring Diagrams
7.5-12.5RT
Ducted Split
2-15
TA5CUN2-01A
Wiring Diagrams
Model No.:TN-C1208T00 Indoor wiring Diagrams
To outdoor Unit
Notes BK BR YL
BLACK BROWN YELLOW
OR RD BL
ORANGE RED BLUE
WH WHITE GN/YL GREEN/YELLOW
Factory wiring Field wiring
Outdoor wiring Diagrams
Outdoor wiring Diagrams
2-16
Ducted Split
7.5-12.5RT
Wiring Diagrams
TA5CUN2-01A
Model No.:TN-C1508T00 Indoor wiring Diagrams
To Outdoor Unit
Notes BK BR YL
BLACK BROWN YELLOW
OR RD BL
ORANGE RED BLUE
WH WHITE GN/YL GREEN/YELLOW
Factory wiring Field wiring
Outdoor wiring Diagrams To Indoor Unit
3ij :,5( a 9 +] POWER SUPPLY
Notes BK BR YL
7.5-12.5RT
BLACK BROWN YELLOW
OR RD BL
ORANGE RED BLUE
WH WHITE GN/YL GREEN/YELLOW
Ducted Split
Factory wiring Field wiring
P/NO:3854A23008W
2-17
Performance Data
TA5CUN2-01A
. . Performance data 9
Outdoor DB(ఁ)
29.4
Indoor WB(ఁ) l/s
16.1
DB(ఁ) TGC
1057
1189
1321
1453
1586
l/s
1057
1189
1321
1453
1586
2-18
22.8
16.1
19.4
22.8
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
23.9
20.3
16.1
6.75
22.5
12.2
6.96
24.2
5.4
7.09
19.6
16.4
7.44
21.7
12.4
7.68
23.3
5.5
7.82
26.7
21.2
18.4
6.77
22.9
15.2
6.98
24.2
10.0
7.11
20.5
18.8
7.46
22.1
15.5
7.70
23.3
10.2
7.84
29.4
22.0
20.2
6.79
23.2
18.3
7.00
24.1
13.8
7.13
21.2
20.6
7.49
22.4
18.7
7.72
23.2
14.1
7.87
32.2
22.7
21.3
6.81
23.5
20.4
7.02
24.0
16.8
7.15
21.9
21.7
7.51
22.6
20.8
7.75
23.1
17.1
7.89
23.9
21.3
17.1
6.80
23.5
13.0
7.02
25.3
5.7
7.15
20.5
17.5
7.50
22.7
13.2
7.74
24.4
5.8
7.88
26.7
22.2
19.7
6.83
23.9
16.2
7.04
25.3
10.6
7.17
21.4
20.0
7.52
23.1
16.6
7.76
24.4
10.8
7.90
29.4
23.0
21.6
6.85
24.3
19.6
7.06
25.2
14.7
7.19
22.2
22.0
7.55
23.4
19.9
7.78
24.3
15.0
7.93
32.2
23.8
22.7
6.87
24.5
21.7
7.08
25.1
17.9
7.21
22.9
22.9
7.57
23.7
22.2
7.81
24.2
18.3
7.95
23.9
21.8
18.4
6.86
24.1
13.9
7.08
25.9
6.1
7.21
21.1
18.7
7.59
23.3
14.2
7.83
25.0
6.3
7.97
26.7
22.8
21.1
6.88
24.6
17.4
7.10
26.0
11.4
7.23
22.0
21.5
7.61
23.7
17.8
7.85
25.0
11.6
8.00
29.4
23.6
23.2
6.90
24.9
21.0
7.12
25.9
15.8
7.25
22.8
22.8
7.63
24.0
21.4
7.87
25.0
16.1
8.02
32.2
24.4
24.4
6.93
25.2
23.3
7.14
25.7
19.2
7.28
23.6
23.6
7.66
24.3
23.8
7.90
24.8
19.6
8.04
23.9
22.2
19.3
6.92
24.5
14.6
7.14
26.4
6.4
7.27
21.4
19.6
7.62
23.7
14.9
7.86
25.5
6.6
8.00
26.7
23.2
22.1
6.94
25.0
18.3
7.16
26.4
12.0
7.29
22.3
22.3
7.64
24.1
18.6
7.88
25.5
12.2
8.03
29.4
24.0
24.0
6.96
25.4
22.0
7.18
26.3
16.5
7.32
23.2
23.2
7.66
24.5
22.4
7.90
25.4
16.9
8.05
32.2
24.8
24.8
6.98
25.6
24.4
7.20
26.2
20.1
7.34
24.0
24.0
7.69
24.7
24.7
7.93
25.2
20.5
8.08
23.9
22.5
19.9
6.98
24.9
15.0
7.20
26.7
6.6
7.33
21.7
20.2
7.68
24.0
15.3
7.92
25.8
6.8
8.06
26.7
23.5
22.8
7.00
25.3
18.8
7.22
26.7
12.3
7.36
22.6
22.6
7.70
24.4
19.2
7.94
25.8
12.6
8.09
29.4
24.4
24.4
7.02
25.7
22.7
7.24
26.7
17.1
7.38
23.5
23.5
7.72
24.8
23.1
7.96
25.7
17.4
8.11
32.2
25.1
25.1
7.04
26.0
25.2
7.26
26.5
20.8
7.40
24.3
24.3
7.74
25.0
25.0
7.99
25.6
21.2
8.14
Outdoor DB(ఁ) Indoor WB(ఁ)
35.0
19.4
46.1
40.6 16.1
DB(ఁ) TGC SHC
19.4 PI
TGC SHC
22.8 PI
TGC SHC
16.1 PI
TGC SHC
51.7
19.4 PI
TGC SHC
22.8 PI
TGC SHC
16.1 PI
TGC SHC
19.4 PI
TGC SHC
22.8 PI
TGC SHC
PI
23.9
18.9 15.9 8.00 20.9 12.1 8.26 22.5
5.3
8.41 17.9 15.5 8.47 19.7 11.8 8.74 21.2
5.2
8.90 16.5 14.8 8.86 18.3 11.2 9.14 19.7
5.0
9.31
26.7
19.7 18.3 8.03 21.3 15.1 8.28 22.5
9.9
8.44 18.6 17.8 8.50 20.1 14.7 8.76 21.2
9.6
8.93 17.3 17.0 8.89 18.6 14.0 9.17 19.7
9.2
9.34
29.4
20.5 20.1 8.05 21.6 18.2 8.31 22.4 13.7 8.46 19.3 19.3 8.52 20.4 17.7 8.79 21.2 13.3 8.95 17.9 17.9 8.91 18.9 16.9 9.19 19.6 12.7 9.37
32.2
21.2 21.1 8.08 21.8 20.2 8.33 22.3 16.7 8.49 20.0 20.0 8.55 20.6 19.7 8.82 21.0 16.2 8.98 18.5 18.5 8.94 19.1 18.8 9.22 19.5 15.5 9.39
23.9
19.8 17.0 8.06 21.9 12.9 8.32 23.5
8.96 17.3 15.8 8.92 19.1 12.0 9.20 20.6
5.3
9.37
26.7
20.7 19.5 8.09 22.3 16.1 8.34 23.5 10.6 8.50 19.5 19.0 8.55 21.0 15.7 8.82 22.2 10.3 8.99 18.1 18.1 8.95 19.5 15.0 9.23 20.6
9.8
9.40
29.4
21.4 21.4 8.11 22.6 19.4 8.37 23.5 14.6 8.52 20.2 20.2 8.58 21.3 18.9 8.85 22.2 14.2 9.01 18.7 18.7 8.97 19.8 18.0 9.26 20.5 13.6 9.43
32.2
22.1 22.1 8.14 22.8 21.6 8.39 23.3 17.8 8.55 20.9 20.9 8.61 21.6 21.0 8.88 22.0 17.3 9.04 19.4 19.4 9.00 20.0 20.0 9.28 20.4 16.5 9.46
23.9
20.3 18.3 8.12 22.5 13.8 8.38 24.2
26.7
21.2 21.0 8.15 22.9 17.3 8.40 24.2 11.3 8.56 20.0 20.0 8.61 21.6 16.9 8.88 22.8 11.0 9.05 18.5 18.5 9.00 20.0 16.1 9.29 21.1 10.5 9.46
29.4
22.0 22.0 8.17 23.2 20.9 8.43 24.1 15.7 8.58 20.8 20.8 8.64 21.9 20.3 8.91 22.7 15.3 9.08 19.2 19.2 9.03 20.3 19.4 9.32 21.1 14.6 9.49
32.2
22.7 22.7 8.19 23.5 23.2 8.45 24.0 19.1 8.61 21.4 21.4 8.66 22.1 22.1 8.94 22.6 18.6 9.10 19.9 19.9 9.06 20.5 20.5 9.34 20.9 17.7 9.52
23.9
20.7 19.1 8.18 22.9 14.5 8.44 24.6
26.7
21.6 21.6 8.20 23.3 18.1 8.46 24.6 11.9 8.62 20.4 20.4 8.67 22.0 17.7 8.94 23.2 11.6 9.11 18.9 18.9 9.06 20.3 16.8 9.35 21.5 11.0 9.52
29.4
22.4 22.4 8.23 23.6 21.8 8.49 24.5 16.4 8.65 21.1 21.1 8.70 22.3 21.3 8.97 23.1 16.0 9.14 19.6 19.6 9.09 20.6 20.3 9.38 21.4 15.3 9.55
32.2
23.1 23.1 8.25 23.9 23.9 8.51 24.4 20.0 8.67 21.8 21.8 8.72 22.5 22.5 9.00 23.0 19.5 9.16 20.2 20.2 9.12 20.9 20.9 9.40 21.3 18.6 9.58
23.9
20.9 19.7 8.24 23.2 14.9 8.50 24.9
26.7
21.8 21.8 8.26 23.6 18.7 8.52 24.9 12.3 8.68 20.6 20.6 8.73 22.2 18.2 9.00 23.5 11.9 9.17 19.1 19.1 9.12 20.6 17.4 9.41 21.8 11.4 9.58
29.4
22.7 22.7 8.29 23.9 22.5 8.55 24.8 16.9 8.71 21.4 21.4 8.76 22.6 21.9 9.03 23.4 16.5 9.20 19.8 19.8 9.15 20.9 20.9 9.44 21.7 15.7 9.61
32.2
23.4 23.4 8.31 24.2 24.2 8.57 24.7 20.6 8.73 22.1 22.1 8.78 22.8 22.8 9.06 23.3 20.1 9.23 20.5 20.5 9.18 21.1 21.1 9.47 21.6 19.2 9.64
5.7
6.1
6.4
6.6
8.47 18.7 16.6 8.53 20.7 12.5 8.80 22.2
8.53 19.2 17.8 8.59 21.2 13.5 8.86 22.8
8.59 19.5 18.6 8.64 21.6 14.1 8.92 23.2
8.66 19.8 19.2 8.70 21.8 14.5 8.98 23.5
Ducted Split
5.5
5.9
6.2
6.4
9.02 17.8 17.0 8.98 19.6 12.8 9.26 21.1
9.08 18.1 17.8 9.04 20.0 13.5 9.32 21.5
9.14 18.3 18.3 9.09 20.2 13.9 9.38 21.8
5.7
5.9
6.1
9.43
9.49
9.55
7.5-12.5RT
Performance Data
TA5CUN2-01A
ΦΥΕΠΠΣ͑͵ͳ͙ఁ͚
ͣͪͥ͟
ͺΟΕΠΠΣ͑Έͳ͙ఁ͚ l͠Τ ͵ͳ͙ఁ͚ ΅ʹ
ͤͦͪ͢
ͦͣͪ͢
ͧͪͪ͢
ͩͧͪ͢
ͣͤͪ͡
l͠Τ
ͤͦͪ͢
ͦͣͪ͢
ͧͪͪ͢
ͩͧͪ͢
ͣͤͪ͡
PI
ͤͦ͟͡
΅ʹ
ͪͥ͢͟ ΄ʹ
PI
΅ʹ
ͣͣͩ͟ ΄ʹ
PI
΅ʹ
ͧ͢͟͢ ΄ʹ
PI
΅ʹ
ͪͥ͢͟ ΄ʹ
PI
΅ʹ
ͣͣͩ͟ ΄ʹ
PI
ͣͤͪ͟
ͣͨͪ͟
ͣͣ͟͢
ͪͥͪ͟
ͤͪ͟͡
ͧͨ͢͟
ͪͨͪ͟
ͤͤͣ͟
ͨͥ͟
ͪͪͨ͟
ͣͧͪ͟
ͣͣͦ͟
ͥͨ͢͟͡
ͣͪͩ͟
ͨ͢͟͡
ͩ͢͟͡͡
ͤͣ͟͡
ͨͦ͟
͢͢͟͡͡
ͣͧͨ͟
ͣͪ͟͢
ͣͦͤ͟
ͪͦͣ͟
ͤͥ͢͟
ͣͪ͟͡
ͪͩͣ͟
ͤͤͣ͟
ͤͨ͢͟
͢͟͡͡͡
ͣͩ͟͢
ͣͦͩ͟
ͦ͢͟͡͡
ͤͤ͟͡
ͣͤ͢͟
ͩͤ͢͟͡
ͤͣ͟͡
ͥ͢͟͡
ͤ͢͢͟͡
ͣͪͥ͟
ͤͣ͟͡
ͣͨͩ͟
ͪͦͦ͟
ͤͪ͢͟
ͣͦͣ͟
ͪͩͦ͟
ͤͤ͟͢
ͪ͢͟͡
ͤ͢͟͡͡
ͣͪͣ͟
ͣͩͤ͟
ͦͤ͢͟͡
ͤͩ͟͡
ͣͦͨ͟
ͩͧ͢͟͡
ͤͣ͟͡
ͪͤ͢͟
ͧ͢͢͟͡
ͤͣͣ͟
ͤͣ͢͟
ͣͪͣ͟
ͪͦͨ͟
ͤͣͣ͟
ͣͩ͟͡
ͪͩͩ͟
ͤͣͪ͟
ͣͤ͟͢
ͧ͢͟͡͡
ͤ͟͢͡
ͣͪͩ͟
ͦͧ͢͟͡
ͤ͢͟͢
ͣͩͦ͟
ͩͪ͢͟͡
ͤͩ͢͟
ͣͤͦ͟
͢͢͟͢͡
ͣͤͪ͟
ͣͪͣ͟
ͣͤͦ͟
ͪͦͨ͟
ͤͣͤ͟
ͨͩ͢͟
ͪͩͨ͟
ͤͥͨ͟
ͨͪ͟
ͧ͢͟͡͡
ͣͩͣ͟
ͣͥ͟͡
ͦͦ͢͟͡
ͤͣ͢͟
ͩͣ͢͟
ͩͩ͢͟͡
ͤͤͦ͟
ͩ͟͡
ͩ͢͢͟͡
ͣͧͨ͟
ͤͦ͟͡
ͣͨ͟͡
ͪͧ͟͡
ͤͣͪ͟
ͣͣͤ͟
ͪͪ͟͡
ͤͥͩ͟
ͥͧ͢͟
ͪ͢͟͡͡
ͣͪͥ͟
ͣͨͧ͟
ͦͩ͢͟͡
ͤͨ͢͟
ͣͣͩ͟
ͪ͢͟͢͡
ͤͤͦ͟
ͥͪ͢͟
ͣ͢͢͟͢
ͣͪͥ͟
ͤͨ͢͟
ͣͪͧ͟
ͪͧͤ͟
ͤͤͥ͟
ͣͧͪ͟
ͪͪͤ͟
ͤͥͨ͟
ͣͣ͟͡
ͣ͢͟͢͡
ͤͦ͟͡
ͤͣ͟͡
ͧ͢͟͢͡
ͤͣͣ͟
ͣͨͥ͟
ͪͦ͢͟͡
ͤͤͥ͟
ͣͧ͟͡
ͦ͢͢͟͢
ͤͣͣ͟
ͤͣͨ͟
ͤͣ͢͟
ͪͧͧ͟
ͤͤͨ͟
ͣͪͪ͟
ͪͪͧ͟
ͤͥͦ͟
ͣͥͧ͟
ͦ͢͟͢͡
ͤͦ͢͟
ͤͦ͢͟
ͧͥ͢͟͡
ͤͣͦ͟
ͤͥ͟͡
ͪͩ͢͟͡
ͤͤͣ͟
ͣͦ͟͢
ͩ͢͢͟͢
ͣͤͪ͟
ͤ͟͡͡
ͣͦͤ͟
ͪͧͦ͟
ͤͤͣ͟
ͪ͢͟͢
ͪͪͧ͟
ͤͦͨ͟
ͩͦ͟
ͥ͢͟͢͡
ͣͪ͟͡
ͣͦͩ͟
ͧͨ͢͟͡
ͤͣ͟͡
ͪͦ͢͟
͢͢͟͢͡
ͤͥͥ͟
ͩͧ͟
ͣ͢͢͟͢
ͣͧͨ͟
ͤͤ͢͟
ͣͪ͟͡
ͪͧͩ͟
ͤͤͩ͟
ͣͥ͟͡
ͪͪͪ͟
ͤͦͨ͟
ͦͨ͢͟
ͨ͢͟͢͡
ͤͣ͟͡
ͣͪͧ͟
ͨ͢͟͡͡
ͤͣͧ͟
ͣͥͥ͟
ͥ͢͢͟͡
ͤͥͥ͟
ͧ͢͟͡
ͣͥ͢͢͟
ͣͪͥ͟
ͤͣͦ͟
ͤͩ͢͟
ͪͨ͟͢
ͤͥͤ͟
ͣͩͪ͟
ͣ͢͟͡͡
ͤͦͧ͟
ͣͨ͢͟
ͣ͢͟͡͡
ͤͤ͢͟
ͤͤ͢͟
ͨͤ͢͟͡
ͤͤ͟͢
ͣͪͥ͟
ͨ͢͢͟͡
ͤͥͤ͟
ͣͣ͟͢
ͣͩ͢͢͟
ͤͣͣ͟
ͤͤͧ͟
ͤͤͦ͟
ͪͨͥ͟
ͤͥͧ͟
ͤͣ͟͢
ͦ͢͟͡͡
ͤͦͥ͟
ͣͧͦ͟
ͣͤ͢͟͡
ͤͣͥ͟
ͤͣͥ͟
ͨͨ͢͟͡
ͤͤͥ͟
ͤͣͨ͟
͢͢͟͢͢
ͤͥ͟͢
ͣͨ͟͡
ͤ͢͢͟͢
ͣͤͪ͟
ͤͦ͟͡
ͣͧͦ͟
ͪͨͤ͟
ͤͤͨ͟
ͣ͟͡͡
ͥ͢͟͡͡
ͤͧͤ͟
ͩͩ͟
ͣͤ͢͟͡
ͣͪͥ͟
ͣͨ͟͡
ͨ͢͟͢͡
ͤͣͧ͟
ͣͥ͟͡
ͦ͢͢͟͡
ͤͦ͟͡
ͪ͟͡
ͣͧ͢͢͟
ͣͧͨ͟
ͤͩ͢͟
ͤͥ͟͡
ͪͨͧ͟
ͤͥͥ͟
ͣͦ͟͢
ͨ͢͟͡͡
ͤͧͤ͟
ͧͥ͢͟
ͣͧ͢͟͡
ͤͨ͟͡
ͤͨ͟͡
ͨͥ͢͟͡
ͤͤ͟͢
ͣͦͧ͟
ͩ͢͢͟͡
ͤͦ͟͡
ͧͩ͢͟
ͣͪ͢͢͟
ͣͪͥ͟
ͤͤ͟͡
ͤͤ͟͡
ͪͨͪ͟
ͤͥͩ͟
ͤͣ͟͡
͢͟͢͡͡
ͤͧͣ͟
ͣͣͨ͟
ͣͪ͢͟͡
ͤͪ͢͟
ͤͪ͢͟
ͨͩ͢͟͡
ͤͤͧ͟
ͤͩ͟͡
ͣ͢͢͟͢
ͤͥͪ͟
ͣͤͣ͟
ͤͣ͢͢͟
ͤͣͣ͟
ͤͥ͟͢
ͤͥ͟͢
ͪͩͣ͟
ͤͦͣ͟
ͤͤͧ͟
ͤ͢͟͢͡
ͤͧ͟͡
ͣͨͨ͟
ͤͣ͢͟͡
ͤͣͪ͟
ͤͣͪ͟
ͩ͢͟͢͡
ͤͥ͟͡
ͤͥ͟͡
ͦ͢͢͟͢
ͤͥͨ͟
ͣͩͣ͟
ͤͧ͢͢͟
ͣͤͪ͟
ͤͪ͟͡
ͣͨͤ͟
ͪͩͣ͟
ͤͥͣ͟
ͣͨ͟͡
ͤ͢͟͢͡
ͤͧͨ͟
ͪ͟͢
ͤ͢͟͢͡
ͣͪͩ͟
ͣͨͩ͟
ͨͪ͢͟͡
ͤͤ͟͡
ͣ͢͟͢
ͤ͢͢͟͢
ͤͦͥ͟
ͪͤ͟
ͤͥ͢͢͟
ͣͧͨ͟
ͤͣͤ͟
ͤͥ͢͟
ͪͩͦ͟
ͤͥͩ͟
ͣͦͪ͟
ͧ͢͟͢͡
ͤͧͩ͟
ͨ͢͟͡
ͤͥ͢͟͡
ͤ͢͟͢
ͤ͢͟͢
ͩͤ͢͟͡
ͤͤͧ͟
ͣͧͥ͟
ͨ͢͢͟͢
ͤͦͦ͟
ͨͤ͢͟
ͤͩ͢͢͟
ͣͪͥ͟
ͤͤͦ͟
ͤͤͦ͟
ͪͩͩ͟
ͤͦͤ͟
ͤͣ͢͟
ͪ͢͟͢͡
ͤͧͨ͟
ͣͤͦ͟
ͤͩ͢͟͡
ͤͣͤ͟
ͤͣͤ͟
ͩͧ͢͟͡
ͤͥ͟͡
ͤͩ͢͟
ͣ͢͢͟͡
ͤͦͥ͟
ͣͤͪ͟
ͥ͢͢͟͢
ͤͣͣ͟
ͤͥͧ͟
ͤͥͧ͟
ͪͪ͟͡
ͤͦͨ͟
ͤͥͧ͟
ͣͣ͢͟͡
ͤͧͥ͟
ͣͩͧ͟
ͥ͢͟͢͡
ͤͤͤ͟
ͤͤͤ͟
ͩͪ͢͟͡
ͤͥͥ͟
ͤͥͥ͟
ͣͥ͢͢͟
ͤͦ͟͢
ͣͪ͟͢
ͥͥ͢͢͟
PI
΅ʹ ΄ʹ
ΦΥΕΠΠΣ͑͵ͳ͙ఁ͚ ͺΟΕΠΠΣ͑Έͳ͙ఁ͚
ͧ͢͟͢ ΄ʹ
ͥͧ͟͡ ͧ͢͟͢
͵ͳ͙ఁ͚ ΅ʹ ΄ʹ
ͥͧ͟͢
ͪͥ͢͟ PI
΅ʹ ΄ʹ
ͣͣͩ͟ PI
΅ʹ ΄ʹ
ͧ͢͟͢ PI
΅ʹ ΄ʹ
ͦͨ͢͟
ͪͥ͢͟ PI
΅ʹ ΄ʹ
ͣͣͩ͟ PI
΅ʹ ΄ʹ
ͧ͢͟͢ PI
΅ʹ ΄ʹ
ͪͥ͢͟ PI
΅ʹ ΄ʹ
ͣͣͩ͟ PI
ͣͤͪ͟
ͣͧ͟͡ ͣͪ͢͟ ͣͧ͢͢͟ ͣͩͩ͟ ͧͧ͢͟ ͧ͢͢͟͢ ͤͪ͟͡ ͨͤ͟ ͩͤ͢͢͟ ͣͥͦ͟ ͣͤ͢͟ ͪ͢͢͟͢ ͣͨ͟͢ ͧͣ͢͟ ͣͣͪ͢͟ ͣͪͣ͟ ͨ͟͢ ͣͦͣ͢͟ ͣͣͨ͟ ͣͥ͟͡ ͣͥͧ͢͟ ͣͦ͟͢ ͦͥ͢͟ ͣͩͦ͢͟ ͣͨ͟͡ ͧͩ͟ ͤͪ͢͟͡
ͣͧͨ͟
ͣͨ͟͢ ͣͦͣ͟ ͣͪ͢͢͟ ͣͪͤ͟ ͣͩ͟͡ ͧͦ͢͢͟ ͤͪ͟͡ ͤͧ͢͟ ͩͧ͢͢͟ ͣͦͧ͟ ͣͥͦ͟ ͪͦ͢͢͟ ͣͨͧ͟ ͣͣ͟͡ ͣͤͣ͢͟ ͣͪͣ͟ ͤͣ͢͟ ͣͦͦ͢͟ ͣͤͨ͟ ͣͤͥ͟ ͣͦ͢͟͡ ͣͦͧ͟ ͪͤ͢͟ ͣͩͪ͢͟ ͣͨ͟͡ ͣͧ͢͟ ͤͤ͢͟͢
ͣͪͥ͟
ͣͩͣ͟ ͣͨͧ͟ ͤͤ͢͢͟ ͣͪͨ͟ ͣͦ͟͡ ͧͩ͢͢͟ ͤͩ͟͡ ͩͩ͢͟ ͪ͢͢͟͡ ͣͧͧ͟ ͣͧͧ͟ ͪͩ͢͢͟ ͣͩ͟͡ ͣͥͥ͟ ͣͤͧ͢͟ ͣͪ͟͢ ͩͤ͢͟ ͣͦͪ͢͟ ͣͥͧ͟ ͣͥͧ͟ ͣͦͥ͢͟ ͣͧ͟͡ ͣͤͣ͟ ͣͪͤ͢͟ ͣͨ͟͡ ͨͦ͢͟ ͤͨ͢͟͢
ͤͣͣ͟
ͣͪ͟͢ ͣͪ͟͡ ͤͧ͢͢͟ ͤ͟͡͡ ͣͨͩ͟ ͨͣ͢͢͟ ͤͨ͟͡ ͣͣͪ͟ ͪͤ͢͢͟ ͣͨͥ͟ ͣͨͥ͟ ͣͣ͢͟͡ ͣͩͤ͟ ͣͨ͟͢ ͣͥ͢͟͡ ͣͩͪ͟ ͣͣͤ͟ ͣͧͤ͢͟ ͣͦͥ͟ ͣͦͥ͟ ͣͦͨ͢͟ ͣͧͣ͟ ͣͦͩ͟ ͣͪͨ͢͟ ͣͧͩ͟ ͣͤ͢͟ ͤͣ͢͟͢
ͣͤͪ͟
ͣͨͣ͟ ͣͤͥ͟ ͤͥ͢͢͟ ͤ͟͢͡ ͨͨ͢͟ ͨ͢͢͟͡ ͤͣͤ͟ ͨͩ͟ ͪ͢͢͟͢ ͣͦͨ͟ ͣͣͩ͟ ͪͪ͢͢͟ ͣͩͥ͟ ͨͣ͢͟ ͣͤͨ͢͟ ͤͦ͟͡ ͨͧ͟ ͣͧ͢͟͡ ͣͤͩ͟ ͣͨ͢͟ ͣͦͥ͢͟ ͣͧͤ͟ ͧͥ͢͟ ͣͪͥ͢͟ ͣͩͤ͟ ͨͤ͟ ͤͩ͢͟͢
ͣͧͨ͟
ͣͩͥ͟ ͣͧͪ͟ ͤͨ͢͢͟ ͤͧ͟͡ ͣͣͣ͟ ͨͤ͢͢͟ ͤͣͥ͟ ͥͦ͢͟ ͪͦ͢͢͟ ͣͧͩ͟ ͣͧ͟͢ ͣͤ͢͟͡ ͣͩͪ͟ ͣͧ͢͟ ͣͥ͢͟͢ ͤͦ͟͡ ͥ͢͟͢ ͣͧͥ͢͟ ͣͥͩ͟ ͣͥͩ͟ ͣͦͩ͢͟ ͣͧͩ͟ ͣͧ͟͡ ͣͪͩ͢͟ ͣͩͤ͟ ͤͦ͢͟ ͤͣͣ͢͟
ͣͪͥ͟
ͣͪͦ͟ ͣͪͥ͟ ͥ͢͢͟͢ ͤ͢͟͢ ͣͧͨ͟ ͨͨ͢͢͟ ͤͣͤ͟ ͣ͟͢͡ ͪͪ͢͢͟ ͣͨͩ͟ ͣͨͩ͟ ͣͨ͢͟͡ ͣͪͤ͟ ͣͧ͟͡ ͣͥͦ͢͟ ͤͦ͟͡ ͪͧ͢͟ ͣͧͩ͢͟ ͣͦͩ͟ ͣͦͩ͟ ͣͧͣ͢͟ ͣͨͣ͟ ͣͥͩ͟ ͤͣ͢͟͡ ͣͩͣ͟ ͩͨ͢͟ ͤͣͧ͢͟
ͤͣͣ͟
ͤͥ͟͡ ͤͥ͟͡ ͥͥ͢͢͟ ͤͥ͢͟ ͣͪͨ͟ ͩ͢͢͟͡ ͤͣ͟͢ ͣͥͦ͟ ͣͣ͢͟͡ ͣͩͨ͟ ͣͩͨ͟ ͣ͢͟͢͡ ͣͪͧ͟ ͣͩͪ͟ ͣͥͩ͢͟ ͤͤ͟͡ ͣͤͩ͟ ͣͨͣ͢͟ ͣͧͧ͟ ͣͧͧ͟ ͣͧͧ͢͟ ͣͨͦ͟ ͣͨͦ͟ ͤͧ͢͟͡ ͣͩ͟͡ ͣͣͨ͟ ͤͤ͢͟͡
ͣͤͪ͟
ͣͨͪ͟ ͣͦ͟͢ ͥͣ͢͢͟ ͤͪ͟͡ ͪ͢͟͡ ͨͩ͢͢͟ ͤͤͣ͟ ͩͥ͟ ͣ͢͟͡͡ ͣͧͥ͟ ͣͥͥ͟ ͣͩ͢͟͡ ͣͪ͟͢ ͩͦ͢͟ ͣͥͧ͢͟ ͤͤ͢͟ ͩͣ͟ ͣͧͪ͢͟ ͣͥͥ͟ ͣͤͤ͟ ͣͧͣ͢͟ ͣͨ͟͡ ͨͨ͢͟ ͤͣ͢͟͡ ͣͪ͟͡ ͨͩ͟ ͤͣͧ͢͟
ͣͧͨ͟
ͣͪ͟͢ ͣͩͩ͟ ͥͧ͢͢͟ ͤͥ͢͟ ͣͤͩ͟ ͩͣ͢͢͟ ͤͤͣ͟ ͦͧ͢͟ ͣͥ͢͟͡ ͣͨͦ͟ ͣͨͦ͟ ͣ͢͟͢͢ ͣͪͨ͟ ͣͤͣ͟ ͣͥͪ͢͟ ͤͥ͢͟ ͦͣ͢͟ ͣͨͤ͢͟ ͣͦͦ͟ ͣͦͦ͟ ͣͧͧ͢͟ ͣͨͦ͟ ͣͣ͟͢ ͤͧ͢͟͡ ͣͪ͟͡ ͥͦ͢͟ ͤͤ͢͟͡
ͣͪͥ͟
ͤͣ͟͡ ͤͣ͟͡ ͥͪ͢͢͟ ͤͪ͢͟ ͣͩͨ͟ ͩͦ͢͢͟ ͤͤ͟͢ ͣͧ͢͟ ͣͨ͢͟͡ ͣͩͦ͟ ͣͩͦ͟ ͣͦ͢͟͢ ͤ͟͢͡ ͣͨͪ͟ ͣͦͤ͢͟ ͤͤ͢͟ ͣ͢͟͡ ͣͨͧ͢͟ ͣͧͥ͟ ͣͧͥ͟ ͣͨ͢͟͡ ͣͨͪ͟ ͣͧͧ͟ ͤ͢͟͢͡ ͣͪ͟͡ ͣ͟͡͡ ͤͤͥ͢͟
ͤͣͣ͟
ͤͣ͢͟ ͤͣ͢͟ ͦͣ͢͢͟ ͤͣͣ͟ ͤͪ͢͟ ͩͪ͢͢͟ ͤͣͪ͟ ͣͧͤ͟ ͣ͢͟͢͢ ͣͪͦ͟ ͣͪͦ͟ ͣͩ͢͟͢ ͤͥ͟͡ ͤͥ͟͡ ͣͦͨ͢͟ ͤ͢͟͢ ͣͦͧ͟ ͣͩ͢͟͡ ͣͨͤ͟ ͣͨͤ͟ ͣͨͥ͢͟ ͣͩͣ͟ ͣͩͣ͟ ͤͥ͢͟͢ ͣͩͩ͟ ͣͥͥ͟ ͤͤͩ͢͟
ͣͤͪ͟
ͣͩͥ͟ ͣͧͤ͟ ͦ͢͢͟͡ ͤͥ͢͟ ͪͪ͢͟ ͩͨ͢͢͟ ͤͤͩ͟ ͩͩ͟ ͣͪ͢͟͡ ͣͧͩ͟ ͣͦͧ͟ ͣͧ͢͟͢ ͣͪͧ͟ ͪͥ͢͟ ͣͦͥ͢͟ ͤͪ͢͟ ͩͧ͟ ͣͨͨ͢͟ ͣͥͩ͟ ͣͥͥ͟ ͣͨ͢͟͢ ͣͨͦ͟ ͩͦ͢͟ ͤ͢͟͢͢ ͣͪͦ͟ ͩͣ͟ ͤͤͦ͢͟
ͣͧͨ͟
ͣͪͧ͟ ͣͪͧ͟ ͦͥ͢͢͟ ͤͣ͟͡ ͣͥͪ͟ ͪ͢͢͟͡ ͤͤͩ͟ ͧͤ͢͟ ͣͣ͢͟͢ ͣͩ͟͡ ͣͩ͟͡ ͣͪ͢͟͢ ͤͣ͟͡ ͣͥͤ͟ ͣͦͩ͢͟ ͤͪ͢͟ ͦͪ͢͟ ͣͩ͢͟͢ ͣͦͪ͟ ͣͦͪ͟ ͣͨͦ͢͟ ͣͩ͟͡ ͣͤͣ͟ ͤͦ͢͟͢ ͣͪͦ͟ ͦͣ͢͟ ͤͤͪ͢͟
ͣͪͥ͟
ͤͩ͟͡ ͤͩ͟͡ ͦͨ͢͢͟ ͤͣͥ͟ ͤ͟͡͡ ͪͥ͢͢͟ ͤͤͨ͟ ͣͣͧ͟ ͣͧ͢͟͢ ͣͪ͟͡ ͣͪ͟͡ ͣͣͤ͢͟ ͤͧ͟͡ ͣͪͣ͟ ͣͧͣ͢͟ ͤͩ͢͟ ͣͣ͟͡ ͣͩͦ͢͟ ͣͧͪ͟ ͣͧͪ͟ ͣͨͩ͢͟ ͣͩͥ͟ ͣͨͪ͟ ͤͪ͢͟͢ ͣͪͦ͟ ͣ͢͟͡ ͤͥͤ͢͟
ͤͣͣ͟
ͤͩ͢͟ ͤͩ͢͟ ͧ͢͢͟͢ ͤͣͩ͟ ͤͣͩ͟ ͪͨ͢͢͟ ͤͤͦ͟ ͣͨͦ͟ ͣͣ͢͟͡ ͤ͟͡͡ ͤ͟͡͡ ͣͣͨ͢͟ ͤͪ͟͡ ͤͪ͟͡ ͣͧͦ͢͟ ͤͧ͢͟ ͣͧͩ͟ ͣͩͪ͢͟ ͣͨͩ͟ ͣͨͩ͟ ͣͩͣ͢͟ ͣͩͨ͟ ͣͩͨ͟ ͤͣͤ͢͟ ͣͪͤ͟ ͣͦͦ͟ ͤͥͨ͢͟
ͣͤͪ͟
ͣͩͩ͟ ͣͨ͟͢ ͦͪ͢͢͟ ͤͩ͢͟ ͣͦ͟͡ ͪͦ͢͢͟ ͤͥͣ͟ ͪ͟͢ ͣͨ͢͟͢ ͣͨͣ͟ ͣͧͥ͟ ͣͣͥ͢͟ ͤ͟͡͡ ͣ͟͡͡ ͣͧͤ͢͟ ͤͣͤ͟ ͩͩ͟ ͣͩͧ͢͟ ͣͦͣ͟ ͣͦͣ͟ ͣͨͪ͢͟ ͣͨͩ͟ ͪ͢͟͢ ͤͪ͢͟͢ ͣͪͪ͟ ͩͥ͟ ͤͥͥ͢͟
ͣͧͨ͟
ͤ͟͡͡ ͤ͟͡͡ ͧͣ͢͢͟ ͤͣͥ͟ ͣͦͨ͟ ͪͪ͢͢͟ ͤͥͣ͟ ͧͩ͢͟ ͣͣ͢͟͢ ͣͩͤ͟ ͣͩͤ͟ ͣͣͩ͢͟ ͤͧ͟͡ ͣͦ͟͡ ͣͧͧ͢͟ ͤͣͤ͟ ͧͥ͢͟ ͣͪ͢͟͡ ͣͧͣ͟ ͣͧͣ͟ ͣͩͤ͢͟ ͣͩͤ͟ ͣͤͪ͟ ͤͣͤ͢͟ ͣͪͪ͟ ͦͧ͢͟ ͤͥͩ͢͟
ͣͪͥ͟
ͤͣ͢͟ ͤͣ͢͟ ͧͧ͢͢͟ ͤͣͪ͟ ͤ͢͟͡ ͣͣ͢͟͡ ͤͥ͟͢ ͣͤͤ͟ ͣͣͦ͢͟ ͣͪͥ͟ ͣͪͥ͟ ͣͤ͢͟͢ ͤ͢͟͡ ͤ͟͢͡ ͣͨ͢͟͡ ͤͣͣ͟ ͣͣͨ͟ ͣͪͥ͢͟ ͣͨͣ͟ ͣͨͣ͟ ͣͩͨ͢͟ ͣͩͨ͟ ͣͩͨ͟ ͤͣͨ͢͟ ͣͪͩ͟ ͣͧ͢͟ ͤͦͣ͢͟
ͤͣͣ͟
ͤͣͣ͟ ͤͣͣ͟ ͧͪ͢͢͟ ͤͤͣ͟ ͤͤͣ͟ ͣͧ͢͟͡ ͤͤͪ͟ ͣͩͥ͟ ͣͣͩ͢͟ ͤͥ͟͡ ͤͥ͟͡ ͣͤͦ͢͟ ͤͤ͢͟ ͤͤ͢͟ ͣͨͥ͢͟ ͤͣ͟͡ ͣͨͧ͟ ͣͪͩ͢͟ ͣͩ͟͢ ͣͩ͟͢ ͣͪ͢͟͡ ͣͪ͟͡ ͣͪ͟͡ ͤͤ͢͟͢ ͣͪͨ͟ ͣͧͤ͟ ͤͦͧ͢͟
7.5-12.5RT
Ducted Split
2-19
TA5CUN2-01A
Performance Data
table-3 Model No.:TN-C1508T00 Outdoor DB(ć) Indoor WB(ć) l/s DB(ć) 23.9 26.7 1661 29.4 32.2 23.9 26.7 1869 29.4 32.2 23.9 26.7 2076 29.4 32.2 23.9 26.7 2284 29.4 32.2 23.9 26.7 2492 29.4 32.2
Outdoor DB(ć) Indoor WB(ć) l/s DB(ć) 23.9 26.7 1661 29.4 32.2 23.9 26.7 1869 29.4 32.2 23.9 26.7 2076 29.4 32.2 23.9 26.7 2284 29.4 32.2 23.9 26.7 2492 29.4 32.2
TGC 34.0 35.4 36.8 38.0 35.5 37.1 38.5 39.7 36.5 38.1 39.5 40.8 37.1 38.7 40.2 41.5 37.6 39.2 40.7 42.0
TGC 30.9 32.2 33.5 34.6 32.3 33.8 35.0 36.2 33.2 34.6 36.0 37.1 33.8 35.2 36.6 37.8 34.2 35.7 37.0 38.3
16.1 SHC 26.1 29.9 32.8 34.5 27.8 31.9 35.0 36.2 29.9 34.3 36.0 37.1 31.3 35.3 36.6 37.8 32.2 35.7 37.1 38.3
16.1 SHC 26.8 30.8 33.8 35.6 28.6 32.9 36.0 37.9 30.7 35.3 38.7 40.7 32.2 37.0 40.2 41.5 33.2 38.1 40.7 42.0
PI 13.28 13.32 13.36 13.40 13.37 13.41 13.45 13.49 13.47 13.51 13.55 13.59 13.57 13.61 13.65 13.69 13.66 13.70 13.74 13.79
PI 10.61 10.64 10.67 10.70 10.70 10.73 10.76 10.79 10.79 10.82 10.85 10.89 10.88 10.91 10.95 10.98 10.97 11.01 11.04 11.07
TGC 34.2 34.8 35.3 35.7 35.8 36.4 36.9 37.3 36.7 37.4 37.9 38.3 37.3 38.0 38.6 39.0 37.8 38.5 39.1 39.5
40.6 19.4 SHC 20.3 25.4 30.6 34.0 21.7 27.1 32.7 36.3 23.3 29.1 35.1 39.0 24.4 30.5 36.7 40.1 25.1 31.5 37.9 40.6
TGC 37.5 38.2 38.8 39.2 39.3 40.0 40.6 41.0 40.3 41.1 41.7 42.1 41.0 41.8 42.4 42.8 41.6 42.3 42.9 43.4
PI 13.66 13.70 13.74 13.78 13.75 13.80 13.84 13.88 13.85 13.90 13.94 13.98 13.95 14.00 14.04 14.08 14.05 14.10 14.14 14.18
29.4 19.4 SHC 20.3 25.4 30.6 34.0 21.7 27.1 32.7 36.3 23.3 29.2 35.1 39.0 24.4 30.5 36.8 40.8 25.1 31.5 37.9 42.1
TGC 36.8 36.8 36.7 36.5 38.5 38.6 38.5 38.2 39.6 39.6 39.5 39.2 40.2 40.3 40.1 39.9 40.8 40.8 40.7 40.4
22.8 SHC 9.0 16.7 23.0 28.0 9.6 17.8 24.6 29.9 10.3 19.1 26.4 32.1 10.7 20.0 27.6 33.6 11.1 20.6 28.5 34.7
PI 10.94 10.97 11.01 11.04 11.03 11.07 11.10 11.13 11.13 11.16 11.20 11.23 11.22 11.26 11.29 11.32 11.32 11.35 11.39 11.42
PI 13.96 14.00 14.05 14.09 14.06 14.11 14.15 14.19 14.16 14.21 14.25 14.29 14.27 14.31 14.35 14.40 14.37 14.41 14.45 14.50
22.8 SHC 9.0 16.7 23.1 28.1 9.6 17.8 24.6 29.9 10.3 19.1 26.4 32.2 10.8 20.0 27.6 33.7 11.1 20.6 28.5 34.7
TGC 40.4 40.4 40.3 40.0 42.2 42.3 42.1 41.9 43.4 43.4 43.3 43.0 44.1 44.1 44.0 43.7 44.7 44.7 44.6 44.3
TGC 29.1 30.3 31.5 32.5 30.4 31.8 33.0 34.0 31.3 32.6 33.8 34.9 31.8 33.2 34.4 35.5 32.2 33.6 34.9 36.0
16.1 SHC 26.3 30.2 31.5 32.5 28.1 31.8 33.0 34.0 30.1 32.6 33.8 34.9 31.5 33.2 34.4 35.5 32.2 33.6 34.9 36.0
PI 14.78 14.83 14.87 14.91 14.88 14.93 14.97 15.02 14.99 15.03 15.08 15.12 15.09 15.13 15.18 15.22 15.19 15.23 15.28 15.33
PI 11.14 11.18 11.21 11.24 11.24 11.27 11.31 11.34 11.34 11.37 11.40 11.44 11.43 11.47 11.50 11.54 11.53 11.56 11.60 11.63
TGC 32.2 32.7 33.2 33.6 33.7 34.3 34.8 35.1 34.5 35.2 35.7 36.1 35.1 35.8 36.3 36.7 35.6 36.2 36.8 37.1
46.1 19.4 SHC 19.9 24.9 30.0 33.4 21.2 26.6 32.0 35.1 22.8 28.6 34.4 36.1 23.9 29.9 36.0 36.7 24.6 30.9 36.8 37.1
TGC 32.8 34.2 35.5 36.6 34.3 35.8 37.1 38.3 35.2 36.7 38.1 39.4 35.8 37.4 38.8 40.0 36.3 37.8 39.3 40.5
PI 15.25 15.29 15.34 15.39 15.35 15.40 15.45 15.49 15.46 15.50 15.55 15.60 15.56 15.61 15.66 15.70 15.67 15.70 15.76 15.81
16.1 SHC 27.3 31.4 34.4 36.2 29.2 33.5 36.7 38.3 31.3 36.0 38.1 39.4 32.8 37.4 38.8 40.0 33.8 37.8 39.3 40.5
TGC 34.6 34.6 34.5 34.3 36.2 36.2 36.1 35.9 37.1 37.2 37.1 36.8 37.8 37.8 37.7 37.5 38.3 38.3 38.2 37.9
22.8 SHC 8.8 16.3 22.6 27.5 9.4 17.4 24.1 29.3 10.1 18.7 25.9 31.5 10.5 19.6 27.1 33.0 10.9 20.2 27.9 34.0
PI 11.70 11.73 11.77 11.80 11.79 11.83 11.86 11.90 11.93 11.96 12.00 12.03 11.97 12.01 12.05 12.08 12.07 12.10 12.14 12.17
PI 15.53 15.58 15.62 15.67 15.64 15.68 15.73 15.78 15.74 15.79 15.84 15.89 15.85 15.90 15.95 15.99 15.96 16.01 16.05 16.10
TGC 36.2 36.9 37.4 37.8 37.9 38.6 39.1 39.6 38.9 39.6 40.2 40.6 39.6 40.3 40.9 41.3 40.1 40.8 41.4 41.8
TGC 26.9 28.1 29.2 30.1 28.2 29.4 30.5 31.5 28.9 30.2 31.3 32.4 29.4 30.7 31.9 32.9 29.8 31.1 32.3 33.3
16.1 SHC 25.1 28.1 29.2 30.1 26.8 29.4 30.5 31.5 28.7 30.2 31.3 32.4 29.4 30.7 31.9 32.9 29.8 31.1 32.3 33.3
35.0 19.4 SHC 20.7 25.9 31.2 34.7 22.1 27.7 33.3 37.0 23.7 29.7 35.8 39.8 24.8 31.1 37.5 41.3 25.6 32.1 38.6 41.8
PI 15.46 15.51 15.56 15.60 15.57 15.61 15.66 15.71 15.67 15.71 15.76 15.81 15.77 15.82 15.86 15.91 15.87 15.92 15.97 16.01
PI 12.07 12.10 12.14 12.18 12.16 12.20 12.24 12.27 12.30 12.34 12.38 12.41 12.35 12.39 12.43 12.46 12.45 12.48 12.52 12.56
TGC 29.8 30.3 30.8 31.1 31.2 31.7 32.2 32.5 32.0 32.6 33.0 33.4 32.5 33.1 33.6 34.0 33.0 33.6 34.0 34.4
51.7 19.4 SHC 19.0 23.8 28.7 31.1 20.3 25.4 30.6 32.5 21.8 27.3 32.8 33.4 22.8 28.5 33.6 34.0 23.5 29.4 34.0 34.4
22.8 SHC 9.1 17.0 23.5 28.6 9.8 18.1 25.1 30.5 10.5 19.5 26.9 32.8 11.0 20.4 28.2 34.3 11.3 21.0 29.1 35.4
TGC 38.9 39.0 38.9 38.6 40.8 40.8 40.7 40.4 41.8 41.9 41.7 41.5 42.6 42.6 42.5 42.2 43.1 43.1 43.0 42.7
PI 15.95 16.00 16.05 16.10 16.06 16.10 16.15 16.20 16.16 16.21 16.26 16.31 16.27 16.32 16.36 16.41 16.37 16.42 16.47 16.52
TGC 32.0 32.0 32.0 31.8 33.5 33.5 33.4 33.2 34.4 34.4 34.3 34.1 35.0 35.0 34.9 34.7 35.4 35.5 35.4 35.1
PI 12.29 12.33 12.37 12.40 12.39 12.42 12.46 12.50 12.53 12.57 12.61 12.64 12.58 12.62 12.66 12.69 12.68 12.71 12.75 12.79
22.8 SHC 8.4 15.6 21.6 26.2 8.9 16.6 23.0 28.0 9.6 17.9 24.7 30.1 10.1 18.7 25.9 31.5 10.4 19.3 26.7 32.5
PI 16.25 16.30 16.34 16.39 16.35 16.40 16.45 16.50 16.46 16.51 16.56 16.61 16.57 16.62 16.67 16.72 16.68 16.73 16.78 16.83
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°C), WB = Wet Bulb Temperature (°C) 3. l/s = Liters per second 4. TGC = Total Gross Cooling Capacity(Unit : kW) 5. SHC = Sensible Heat Capacity(Unit : kW) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
2-20
Ducted Split
7.5-12.5RT
Performance Data
TA5CUN2-01A
10. Performance Data Cooling Capacity(English Units) table-4 Model No.:TN-C0908T00 Outdoor DB(ሥ)
85
Indoor WB(ሥ) CFM
61
DB(ሥ) TGC
2240
2520
2800
3080
3360
3080
3360
67
73
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
69.4
54.8
6.75
76.7
41.5
6.96
82.4
18.3
7.09
66.9
55.8
7.44
74.0
42.3
7.68
79.5
18.7
7.82
80
72.4
62.9
6.77
78.1
52.0
6.98
82.5
34.0
7.11
69.8
64.1
7.46
75.3
53.0
7.70
79.6
34.7
7.84
85
75.1
69.0
6.79
79.2
62.6
7.00
82.2
47.1
7.13
72.4
70.3
7.49
76.4
63.8
7.72
79.3
48.0
7.87
90
77.6
72.6
6.81
80.0
69.5
7.02
81.7
57.3
7.15
74.8
74.0
7.51
77.2
70.9
7.75
78.9
58.4
7.89
75
72.6
58.5
6.80
80.2
44.3
7.02
86.3
19.5
7.15
70.0
59.6
7.50
77.4
45.1
7.74
83.2
19.9
7.88
80
75.7
67.1
6.83
81.7
55.4
7.04
86.3
36.3
7.17
73.1
68.4
7.52
78.8
56.5
7.76
83.3
37.0
7.90
85
78.6
73.6
6.85
82.9
66.8
7.06
86.1
50.2
7.19
75.8
75.0
7.55
79.9
68.1
7.78
83.0
51.2
7.93
90
81.2
77.5
6.87
83.8
74.2
7.08
85.5
61.2
7.21
78.3
78.3
7.57
80.8
75.6
7.81
82.5
62.3
7.95
75
74.5
62.8
6.86
82.4
47.5
7.08
88.6
21.0
7.21
71.9
64.0
7.59
79.5
48.5
7.83
85.4
21.4
7.97
80
77.7
72.1
6.88
83.9
59.5
7.10
88.6
39.0
7.23
75.0
73.5
7.61
80.9
60.7
7.85
85.5
39.7
8.00
85
80.7
79.0
6.90
85.1
71.7
7.12
88.4
53.9
7.25
77.8
77.8
7.63
82.1
73.1
7.87
85.2
55.0
8.02
90
83.3
83.2
6.93
86.0
79.7
7.14
87.8
65.7
7.28
80.4
80.4
7.66
82.9
81.2
7.90
84.7
66.9
8.04
75
75.8
65.7
6.92
83.8
49.8
7.14
90.1
22.0
7.27
73.1
67.0
7.62
80.8
50.7
7.86
86.9
22.4
8.00
80
79.1
75.5
6.94
85.3
62.3
7.16
90.1
40.8
7.29
76.3
76.3
7.64
82.3
63.5
7.88
86.9
41.6
8.03
85
82.1
82.1
6.96
86.5
75.1
7.18
89.9
56.5
7.32
79.2
79.2
7.66
83.5
76.5
7.90
86.7
57.5
8.05
90
84.7
84.7
6.98
87.5
83.4
7.20
89.3
68.8
7.34
81.8
81.8
7.69
84.4
84.4
7.93
86.2
70.1
8.08
75
76.8
67.8
6.98
84.9
51.3
7.20
91.2
22.7
7.33
74.1
69.1
7.68
81.9
52.3
7.92
88.0
23.1
8.06
80
80.1
77.9
7.00
86.4
64.3
7.22
91.3
42.1
7.36
77.3
77.3
7.70
83.3
65.5
7.94
88.1
42.9
8.09
85
83.1
83.1
7.02
87.6
77.4
7.24
91.0
58.2
7.38
80.2
80.2
7.72
84.5
78.9
7.96
87.8
59.4
8.11
90
85.8
85.8
7.04
88.6
86.0
7.26
90.5
70.9
7.40
82.8
82.8
7.74
85.5
85.5
7.99
87.3
72.3
8.14
PI
TGC SHC
61
CFM DB(ሥ) TGC SHC
2800
61
SHC
105
Indoor WB(ሥ)
2520
73
75
Outdoor DB(ሥ)
2240
95
67
115
67 PI
TGC SHC
61
73 PI
TGC SHC
PI
125
67
TGC SHC
PI
TGC SHC
73 PI
TGC SHC
61 PI
TGC SHC
67 PI
TGC SHC
73 PI
75
64.6 54.4 8.00 71.4 41.2 8.26 76.8 18.2 8.41 60.9 53.0 8.47 67.4 40.1 8.74 72.4 17.7 8.90 56.4 50.5 8.86 62.4 38.3 9.14 67.1 16.9 9.31
80
67.4 62.5 8.03 72.7 51.6 8.28 76.8 33.8 8.44 63.6 60.8 8.50 68.6 50.2 8.76 72.5 32.9 8.93 58.9 58.0 8.89 63.5 47.9 9.17 67.1 31.4 9.34
85
69.9 68.5 8.05 73.7 62.2 8.31 76.6 46.8 8.46 66.0 66.0 8.52 69.6 60.5 8.79 72.3 45.5 8.95 61.1 61.1 8.91 64.4 57.7 9.19 66.9 43.4 9.37
90
72.2 72.1 8.08 74.5 69.1 8.33 76.1 56.9 8.49 68.1 68.1 8.55 70.3 67.2 8.82 71.8 55.4 8.98 63.1 63.1 8.94 65.1 64.1 9.22 66.5 52.9 9.39
75
67.6 58.1 8.06 74.7 44.0 8.32 80.3 19.4 8.47 63.8 56.5 8.53 70.5 42.8 8.80 75.8 18.9 8.96 59.1 53.9 8.92 65.3 40.8 9.20 70.2 18.0 9.37
80
70.5 66.7 8.09 76.1 55.1 8.34 80.4 36.1 8.50 66.5 64.9 8.55 71.8 53.6 8.82 75.8 35.1 8.99 61.6 61.6 8.95 66.5 51.1 9.23 70.2 33.5 9.40
85
73.2 73.1 8.11 77.2 66.3 8.37 80.1 49.9 8.52 69.0 69.0 8.58 72.8 64.5 8.85 75.6 48.5 9.01 64.0 64.0 8.97 67.4 61.6 9.26 70.0 46.3 9.43
90
75.6 75.6 8.14 78.0 73.7 8.39 79.6 60.7 8.55 71.3 71.3 8.61 73.6 71.7 8.88 75.2 59.1 9.04 66.1 66.1 9.00 68.2 68.2 9.28 69.6 56.4 9.46
75
69.4 62.3 8.12 76.7 47.2 8.38 82.5 20.8 8.53 65.5 60.7 8.59 72.4 46.0 8.86 77.8 20.3 9.02 60.6 57.9 8.98 67.0 43.9 9.26 72.1 19.4 9.43
80
72.4 71.6 8.15 78.1 59.1 8.40 82.5 38.7 8.56 68.3 68.3 8.61 73.7 57.5 8.88 77.8 37.7 9.05 63.3 63.3 9.00 68.2 54.9 9.29 72.1 36.0 9.46
85
75.1 75.1 8.17 79.2 71.2 8.43 82.3 53.6 8.58 70.9 70.9 8.64 74.7 69.3 8.91 77.6 52.1 9.08 65.7 65.7 9.03 69.2 66.1 9.32 71.9 49.7 9.49
90
77.6 77.6 8.19 80.1 79.1 8.45 81.8 65.2 8.61 73.2 73.2 8.66 75.5 75.5 8.94 77.2 63.5 9.10 67.8 67.8 9.06 70.0 70.0 9.34 71.5 60.6 9.52
75
70.6 65.3 8.18 78.0 49.4 8.44 83.9 21.8 8.59 66.6 63.5 8.64 73.6 48.1 8.92 79.1 21.2 9.08 61.7 60.6 9.04 68.2 45.9 9.32 73.3 20.3 9.49
80
73.6 73.6 8.20 79.4 61.9 8.46 83.9 40.5 8.62 69.5 69.5 8.67 74.9 60.2 8.94 79.2 39.5 9.11 64.3 64.3 9.06 69.4 57.5 9.35 73.3 37.7 9.52
85
76.4 76.4 8.23 80.6 74.6 8.49 83.7 56.1 8.65 72.1 72.1 8.70 76.0 72.6 8.97 79.0 54.6 9.14 66.8 66.8 9.09 70.4 69.2 9.38 73.1 52.1 9.55
90
78.9 78.9 8.25 81.4 81.4 8.51 83.2 68.3 8.67 74.5 74.5 8.72 76.8 76.8 9.00 78.5 66.5 9.16 69.0 69.0 9.12 71.2 71.2 9.40 72.7 63.4 9.58
75
71.5 67.3 8.24 79.0 51.0 8.50 84.9 22.5 8.66 67.4 65.5 8.70 74.6 49.6 8.98 80.2 21.9 9.14 62.5 62.5 9.09 69.1 47.4 9.38 74.2 20.9 9.55
80
74.6 74.6 8.26 80.4 63.9 8.52 85.0 41.8 8.68 70.4 70.4 8.73 75.9 62.1 9.00 80.2 40.7 9.17 65.2 65.2 9.12 70.3 59.3 9.41 74.3 38.8 9.58
85
77.4 77.4 8.29 81.6 76.9 8.55 84.7 57.8 8.71 73.0 73.0 8.76 77.0 74.8 9.03 80.0 56.3 9.20 67.6 67.6 9.15 71.3 71.3 9.44 74.1 53.7 9.61
90
79.9 79.9 8.31 82.5 82.5 8.57 84.2 70.4 8.73 75.4 75.4 8.78 77.8 77.8 9.06 79.5 68.6 9.23 69.9 69.9 9.18 72.1 72.1 9.47 73.6 65.4 9.64
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : kW) 5. SHC = Sensible Heat Capacity(Unit : kW) 6. PI = Power Input Comp + Outdoor Fan Motor (kW)
7.5-12.5RT
Ducted Split
2-21
Performance Data
TA5CUN2-01A
table-5 Model No.:TN-C1208T00 ΦΥΕΠΠΣ͑͵ͳ͙ሥ͚
ͩͦ
ͺΟΕΠΠΣ͑Έͳ͙ሥ͚ ʹͷ; ͵ͳ͙ሥ͚ ΅ʹ
ͧ͢ ΄ʹ
PI
ͪͦͤ͟
ͨͦͤ͟
΅ʹ
ͨͤ ΄ʹ
PI
΅ʹ
ͧ͢ ΄ʹ
΅ʹ
PI
ͨͤ ΄ʹ
ͪͥͪ͟
ͦͥ͢͟͡
ͦͨ͟͡
ͪͨͪ͟
ͤͤ͢͢͟
ͣͦͣ͟
ͪͪͨ͟
ͪͣ͟͡
ͨͧͩ͟
ͥͨ͢͟͡ ͨ͢͢͟͡
ͦͩ͟͢
PI
ͩ͢͟͡͡ ͪͤ͢͟͡
ͣͦͨ͟
͢͢͟͡͡
ͩ͡
ͪͪͦ͟
ͩͦ
ͤͣ͢͟͡
ͩͧͦ͟
ͪͦͣ͟
ͨͤ͢͟͡
ͪͥͩ͟
ͪͦͦ͟
ͩͩ͢͟͡
ͨͥ͢͟
ͪͩͣ͟
ͤͥ͢͢͟
ͥͧͩ͟
͢͟͡͡͡
ͪͧ͟͡
ͩͩ͟͢
ͦ͢͟͡͡ ͤͦ͢͟͡
ͩͧ͟͡
ͪͩͦ͟
ͤ͢͢͟͢
ͧͥͨ͟
ͤ͢͟͡͡
ͪͪͧ͟
ͪͧͧ͟
ͦͤ͢͟͡ ͦ͢͟͡͡
ͨͣͩ͟
ͩͤ͢͟͡ ͪͥ͢͟͡
ͥͨͨ͟
ͤ͢͢͟͡
ͩͨͨ͟
ͩͧ͢͟͡ ͪ͢͟͢͡
ͧͦͪ͟
ͪ͡
ͧͧ͢͟͡
ͪͪͩ͟
ͪͦͨ͟
͢͢͟͡͡
ͪͦͧ͟
ͪͩͩ͟
ͣͥ͢͢͟
ͨͩͩ͟
ͧ͢͢͟͡
ͧ͢͟͡͡ ͣͩ͢͟͡ ͨ͢͢͟͡ ͦͧ͢͟͡ ͧ͢͟͢͡
ͪͨͥ͟
ͩͪ͢͟͡ ͩͥ͢͟͡
ͩͤ͟͡
͢͢͟͢͡
ͨͦ
ͪͪͩ͟
ͩͥ͟͡
ͩ͡
ͥ͢͟͢͡
ͪͣͤ͟
ͪͦͨ͟
ͤ͢͢͟͡
ͧͪ͟͡
ͪͩͨ͟
ͩͧ͢͢͟
ͪͧ͟͡
ͣͤ͢͢͟
ͨͧͣ͟
ͪͪ͟͡
ͩͧ͢͢͟
ͣͧͪ͟
ͧ͢͟͡͡
ͪͧͤ͟
ͩͪ͢͟
ͦͦ͢͟͡ ͧͥ͢͟͡
ͧͣ͟͡
ͩͩ͢͟͡ ͥͥ͢͢͟
ͣͨͥ͟
ͩ͢͢͟͡
ͥͪͪ͟
ͪ͢͟͡͡ ͥ͢͟͡͡
ͪͥ͟͡
ͦͩ͢͟͡ ͩͤ͢͟͡
ͨͨͨ͟
ͪ͢͟͢͡ ͥͦ͢͢͟
ͦͪ͟͡
ͩͦ
ͩ͢͟͡͡ ͢͢͟͢͡
ͪͧͤ͟
ͤͪ͢͢͟
ͪͩ͢͟
ͪͪͤ͟
ͣ͢͢͟͢
ͩͤ͢͢͟
ͧͪ͟͡
ͣ͢͟͢͡ ͥͣ͢͟͡ ͤ͢͟͢͡ ͧ͢͟͢͡ ͪͪ͢͟͡
ͪͤͦ͟
ͪͦ͢͟͡ ͥ͢͢͟͢
ͨͥ͟͡
ͪ͡
ͧ͢͢͢͟ ͧͦ͢͟͡
ͪͧͧ͟
ͦ͢͢͟͢ ͣ͢͟͡͡
ͦ͢͢͟͢
ͪͪͧ͟
ͨͧ͢͢͟
ͩͥ͟͢
ͦ͢͟͢͡ ͨͧ͢͟͡ ͨͧ͢͟͡ ͧͥ͢͟͡ ͢͢͢͟͢ ͤͪ͢͟͡ ͪͩ͢͟͡ ͤͥ͢͢͟
ͩͦͨ͟
ͨͦ
ͣͥ͢͟͡
ͩͧͤ͟
ͪͧͦ͟
ͤͣ͢͢͟
ͩ͢͢͟͢
ͧͦͥ͟
ͪͪͧ͟
ͣͨ͢͢͟
ͣͩͩ͟
ͥ͢͟͢͡
ͧͨ͢͟͡ ͪͣ͢͟͡
ͧͧͧ͟
͢͢͟͢͡ ͨͥ͢͢͟
ͣͪͥ͟
ͩ͡
ͧͪ͢͟͡
ͪͪ͟͢
ͪͧͩ͟
ͣ͢͢͟͢
ͦͤ͢͢͟
ͩͩ͢͟
ͪͪͪ͟
ͣͩ͢͢͟
ͦͤͧ͟
ͨ͢͟͢͡ ͤ͢͟͢͡ ͢͢͟͡͡ ͨ͢͟͡͡ ͣ͢͢͢͟
ͩͤͥ͟
ͥ͢͢͟͡ ͨͦ͢͢͟
ͦͥͧ͟
ͣͥ͢͢͟
ͩͦ
ͪ͢͢͟͡ ͩͧ͢͟͡
ͪ͡
ͥͦ͢͢͟ ͥͥ͢͢͟
ͪͨ͟͢
ͧͪ͢͢͟
ͪͩͧ͟
ͣ͢͟͡͡ ͣͥ͢͢͟
ͨͥ͟͢
ͣ͢͟͡͡ ͨ͢͟͡͡ ͨ͢͟͡͡ ͨͤ͢͟͡ ͣͩ͢͢͟ ͥ͢͟͡͡ ͨ͢͢͟͡ ͨͣ͢͢͟
ͨͦͦ͟
ͣͩ͢͢͟
ͪͨͥ͟
ͩͣ͢͢͟ ͪͦ͢͟͡ ͦ͢͟͡͡ ͣͨ͢͟͡
ͪͤ͟͡
ͣͤ͢͟͡ ͦ͢͢͟͡ ͦ͢͢͟͡ ͨͨ͢͟͡ ͥ͢͢͟͡ ͧ͢͢͢͟ ͢͢͟͢͢ ͧͦ͢͢͟
ͪͣ͟͡
ͨͦ
ͥͣ͢͟͡
ͤ͢͢͟͢
ͪͤ͟͡
ͪͨͤ͟
ͦͣ͢͢͟
ͧͩͥ͟
ͥ͢͟͡͡ ͣͤͩ͢͟
ͤͣ͟͡
ͣͤ͢͟͡ ͦ͢͟͡͡
ͨ͢͟͢͡ ͢͢͢͟͢
ͧͪͨ͟
ͦ͢͢͟͡ ͪͥ͢͢͟
ͤͩ͟͡
ͣͧ͢͢͟
ͩ͡
ͩͨ͢͟͡ ͤͨ͢͟͡
ͪͨͧ͟
ͨͣ͢͢͟
ͩͦͨ͟
ͨ͢͟͡͡ ͣͤͪ͢͟
ͦͧ͟͢
ͣͧ͢͟͡ ͥͩ͢͟͡ ͥͩ͢͟͡ ͨͥ͢͟͡ ͤ͢͢͟͢
ͩͨͤ͟
ͩ͢͢͟͡ ͪͦ͢͢͟
ͦͨͣ͟
ͣͪ͢͢͟
ͩͦ
ͣͩ͢͢͟ ͣͩ͢͢͟
ͪͨͪ͟
ͩͪ͢͢͟ ͤͣ͢͟͡ ͢͟͢͡͡ ͣͤͦ͢͟
ͨͨͧ͟
ͣͪ͢͟͡ ͩͩ͢͟͡ ͩͩ͢͟͡ ͨͩ͢͟͡ ͥͨ͢͢͟ ͦͣ͢͟͡ ͣ͢͢͟͢ ͪͣ͢͢͟
ͨͪ͟͢
ͤͣ͢͢͟
ͪ͡
ͧͦ͢͢͟ ͧͦ͢͢͟
ͪͩͣ͟
ͣͣ͢͟͡ ͥͧ͢͢͟ ͤ͢͟͢͡ ͣͣͩ͢͟
ͪͥͦ͟
ͤͣ͢͟͡ ͣͥ͢͢͟ ͣͥ͢͢͟ ͩ͢͟͢͡ ͧ͢͢͟͡ ͧ͢͢͟͡ ͦ͢͢͟͢ ͩͥ͢͢͟
ͪͧͤ͟
ͤͧ͢͢͟
ͨͦ
ͦͦ͢͟͡
ͪͤͣ͟
ͪͩͣ͟
ͧͧ͢͢͟
ͨͧ͟͡
ͤ͢͟͢͡ ͣͦͥ͢͟
ͤͣ͢͟
ͤ͢͟͢͡ ͩ͢͢͟͡
ͨͪ͢͟͡ ͣͦ͢͢͟
ͨͪ͢͟
ͤ͢͢͟͢ ͣ͢͢͟͡
ͤͨ͢͟
ͤͥ͢͢͟
ͩ͡
͢͢͟͢͡ ͨ͢͟͡͡
ͪͩͦ͟
ͩͨ͢͢͟
ͩͩͥ͟
ͧ͢͟͢͡ ͣͦͦ͢͟
ͦͨͪ͟
ͤͥ͢͟͡ ͧͣ͢͟͡ ͧͣ͢͟͡ ͩͤ͢͟͡ ͥͧ͢͢͟
ͪ͟͢͡
ͨ͢͢͟͢ ͣ͢͢͟͡
ͦͪ͟͡
ͤͩ͢͢͟
ͩͦ
ͥͣ͢͢͟ ͥͣ͢͢͟
ͪͩͩ͟
ͣͦ͢͟͡ ͧͥ͢͟͡ ͪ͢͟͢͡ ͣͦ͢͟͢
ͩ͟͢͡
ͤͩ͢͟͡ ͣ͢͢͟͡ ͣ͢͢͟͡ ͩͧ͢͟͡ ͧͣ͢͢͟ ͩͦ͢͟͡ ͣ͢͢͟͡ ͣͨ͢͟͡
ͩͧ͢͟
ͥ͢͢͟͢
ͪ͡
ͩ͢͢͟͡ ͩ͢͢͟͡
ͪͪ͟͡
ͣͩ͢͢͟ ͩͤ͢͢͟ ͣͣ͢͟͡ ͣͥͥ͢͟
ͪͨͦ͟
ͥ͢͟͢͡ ͤͩ͢͢͟ ͤͩ͢͢͟ ͩͪ͢͟͡ ͨͦ͢͢͟ ͨͦ͢͢͟ ͣͥ͢͢͟ ͣ͢͟͡͡
ͪͪͥ͟
ͥͥ͢͢͟
ͨͦ ͣͩͩ͡
ͤͣͥ͡
ͤͧ͡͡
ͤͪͧ͡
ͥͤͣ͡
ΦΥΕΠΠΣ͑͵ͳ͙ሥ͚ ͺΟΕΠΠΣ͑Έͳ͙ሥ͚
ͦ͢͡ ͧ͢
ʹͷ; ͵ͳ͙ሥ͚ ΅ʹ ΄ʹ
ͣͩͩ͡
ͤͣͥ͡
ͤͧ͡͡
ͤͪͧ͡
ͥͤͣ͡
ͪͦ
ͧͨ ΄ʹ
΅ʹ ΄ʹ
ͩͨͪ͟
ͪͣ͟͢
ͪͦ͟͡
ͧͨ ΄ʹ
΅ʹ
ͦ͢͢
ͧͨ PI
ͪͩͩ͟
PI
ͧ͢
ͨͤ PI
΅ʹ ΄ʹ
PI
΅ʹ ΄ʹ
ͣͦ͢
ͧͨ PI
΅ʹ ΄ʹ
΅ʹ
PI
ͨͤ PI
΅ʹ ΄ʹ
ͧ͢ PI
΅ʹ ΄ʹ
ͧͨ PI
΅ʹ ΄ʹ
ͨͤ PI
΅ʹ ΄ʹ
PI
ͨͦ
ͩͩͩ͟ ͨͥͩ͟ ͣͧ͢͢͟ ͪͩ͟͢ ͦͧͧ͟ ͧ͢͢͟͢ ͦͦ͢͟͡ ͣͦ͟͡ ͩͤ͢͢͟ ͩͤͩ͟ ͨͣͩ͟ ͪ͢͢͟͢ ͪͣͧ͟ ͦͦ͟͢ ͣͣͪ͢͟ ͪͪͧ͟ ͣͥͤ͟ ͣͦͣ͢͟ ͨͨͧ͟ ͧͪͦ͟ ͣͥͧ͢͟ ͩͦͩ͟ ͦͣͧ͟ ͣͩͦ͢͟ ͪͣͣ͟ ͣͤͣ͟ ͤͪ͢͟͡
ͩ͡
ͪͣͧ͟ ͩͦͪ͟ ͣͪ͢͢͟ ͪͪͪ͟ ͨͪ͟͡ ͧͦ͢͢͟ ͦͦ͢͟͡ ͥͧͦ͟ ͩͧ͢͢͟ ͩͨͥ͟ ͩͤͧ͟ ͪͦ͢͢͟ ͪͥͤ͟ ͧͪ͟͡ ͣͤͣ͢͟ ͪͪͧ͟ ͥͦͣ͟ ͣͦͦ͢͟ ͩͪ͟͡ ͨͪͩ͟ ͣͦ͢͟͡ ͩͨͤ͟ ͧͦͪ͟ ͣͩͪ͢͟ ͪͣͤ͟ ͥͤͣ͟ ͤͤ͢͟͢
ͩͦ
ͪͧ͟͢ ͪͥ͟͢ ͤͤ͢͢͟ ͤ͢͢͟͡ ͩͦͥ͟ ͧͩ͢͢͟ ͦͤ͢͟͡ ͧͥͤ͟ ͪ͢͢͟͡ ͪͨ͟͡ ͪͨ͟͡ ͪͩ͢͢͟ ͪͦͧ͟ ͩͤ͟͢ ͣͤͧ͢͟ ͪͪͤ͟ ͧͣͦ͟ ͣͦͪ͢͟ ͩͥ͟͡ ͩͥ͟͡ ͣͦͥ͢͟ ͩͩͧ͟ ͨͪͥ͟ ͣͪͤ͢͟ ͪͣ͟͡ ͦͪͨ͟ ͤͨ͢͟͢
ͪ͡
ͪͪͤ͟ ͪͪ͟͢ ͤͧ͢͢͟ ͣͥ͢͟͡ ͪͥͪ͟ ͨͣ͢͢͟ ͥͧ͢͟͡ ͨͩͤ͟ ͪͤ͢͢͟ ͪͤͨ͟ ͪͤͨ͟ ͣͣ͢͟͡ ͪͧͨ͟ ͪͣͥ͟ ͣͥ͢͟͡ ͪͩͨ͟ ͨͧͣ͟ ͣͧͤ͢͟ ͩͧͩ͟ ͩͧͩ͟ ͣͦͨ͢͟ ͩͪͦ͟ ͩͩͣ͟ ͣͪͨ͢͟ ͪͥ͢͟ ͨͣͨ͟ ͤͣ͢͟͢
ͨͦ
ͪͣͪ͟ ͨͪͩ͟ ͤͥ͢͢͟ ͣͨ͢͟͡ ͧͥ͟͡ ͨ͢͢͟͡ ͥ͢͢͟͡ ͣͧͨ͟ ͪ͢͢͟͢ ͩͨͨ͟ ͨͨͨ͟ ͪͪ͢͢͟ ͪͧͪ͟ ͦͩͩ͟ ͣͤͨ͢͟ ͥͣ͢͟͡ ͣͧ͟͡ ͣͧ͢͟͡ ͩͣ͢͟ ͨͥ͟͢ ͣͦͥ͢͟ ͩͪͩ͟ ͦͧ͟͢ ͣͪͥ͢͟ ͪͧͦ͟ ͣͥͩ͟ ͤͩ͢͟͢
ͩ͡
ͪͧͪ͟ ͪͨ͢͟ ͤͨ͢͢͟ ͥͦ͢͟͡ ͨͦͨ͟ ͨͤ͢͢͟ ͦ͢͢͟͡ ͥͪͧ͟ ͪͦ͢͢͟ ͪͦ͢͟ ͩͪͣ͟ ͣͤ͢͟͡ ͪͩͨ͟ ͨͤͨ͟ ͣͥ͢͟͢ ͥͣ͢͟͡ ͥͩͣ͟ ͣͧͥ͢͟ ͩͥͨ͟ ͩͥͨ͟ ͣͦͩ͢͟ ͪͥ͢͟ ͨͤ͟͡ ͣͪͩ͢͟ ͪͧͧ͟ ͥͧ͟͡ ͤͣͣ͢͟
ͩͦ
ͧ͢͟͡͡ ͥ͢͟͡͡ ͥ͢͢͟͢ ͧ͢͟͢͡ ͪͣ͢͟ ͨͨ͢͢͟ ͢͢͟͢͡ ͧͩͧ͟ ͪͪ͢͢͟ ͪͥͪ͟ ͪͥͪ͟ ͣͨ͢͟͡ ͢͟͢͡͡ ͩͩͨ͟ ͣͥͦ͢͟ ͤͪ͢͟͡ ͧͧͨ͟ ͣͧͩ͢͟ ͩͨͪ͟ ͩͨͪ͟ ͣͧͣ͢͟ ͪͣͨ͟ ͩͥͨ͟ ͤͣ͢͟͡ ͪͧͤ͟ ͧͤͨ͟ ͤͣͧ͢͟
ͪ͡
ͤͪ͢͟͡ ͤͪ͢͟͡ ͥͥ͢͢͟ ͨͣ͢͟͡ ͤ͢͢͟͡ ͩ͢͢͟͡ ͪͦ͢͟͡ ͩͤͦ͟ ͣͣ͢͟͡ ͪͩ͟͡ ͪͩ͟͡ ͣ͢͟͢͡ ͣ͢͢͟͡ ͪͩͧ͟ ͣͥͩ͢͟ ͤͤ͢͟͡ ͩͤ͢͟ ͣͨͣ͢͟ ͪͩ͟͡ ͪͩ͟͡ ͣͧͧ͢͟ ͪͤͨ͟ ͪͤͨ͟ ͤͧ͢͟͡ ͪͦͨ͟ ͨͨͦ͟ ͤͤ͢͟͡
ͨͦ
ͪͦͥ͟ ͩͦͨ͟ ͥͣ͢͢͟ ͦͥ͢͟͡ ͧͥͪ͟ ͨͩ͢͢͟ ͤͤ͢͢͟ ͣͩͧ͟ ͣ͢͟͡͡ ͪ͟͡͡ ͩͤͥ͟ ͣͩ͢͟͡ ͪͪͦ͟ ͧͤͣ͟ ͣͥͧ͢͟ ͨ͢͟͡͡ ͣͨͪ͟ ͣͧͪ͢͟ ͩͤͤ͟ ͨͪͧ͟ ͣͧͣ͢͟ ͪͣ͟͢ ͧͤ͟͡ ͤͣ͢͟͡ ͪͪ͟͢ ͣͧͧ͟ ͤͣͧ͢͟
ͩ͡
ͪͪͦ͟ ͪͩͥ͟ ͥͧ͢͢͟ ͨͤ͢͟͡ ͩͤ͢͟ ͩͣ͢͢͟ ͤͥ͢͢͟ ͦͤͣ͟ ͣͥ͢͟͡ ͪͤͪ͟ ͪͤͪ͟ ͣ͢͟͢͢ ͤ͢͢͟͡ ͨͪ͟͢ ͣͥͪ͢͟ ͨ͢͟͡͡ ͦͩ͢͟ ͣͨͤ͢͟ ͩͨ͟͡ ͩͨ͟͡ ͣͧͧ͢͟ ͪͤͩ͟ ͨͦͦ͟ ͤͧ͢͟͡ ͪͪ͟͢ ͥͪͥ͟ ͤͤ͢͟͡
ͩͦ
ͤͣ͢͟͡ ͤͣ͢͟͡ ͥͪ͢͢͟ ͩͪ͢͟͡ ͪͨͪ͟ ͩͦ͢͢͟ ͤ͢͢͟͢ ͨͤͧ͟ ͣͨ͢͟͡ ͪͨͥ͟ ͪͨͥ͟ ͣͦ͢͟͢ ͣͨ͢͟͡ ͪͦͤ͟ ͣͦͤ͢͟ ͧͨ͢͟͡ ͨͨ͢͟ ͣͨͧ͢͟ ͪͣ͟͡ ͪͣ͟͡ ͣͨ͢͟͡ ͪͦͣ͟ ͪͪ͟͡ ͤ͢͟͢͡ ͪͩͩ͟ ͧͩͥ͟ ͤͤͥ͢͟
ͪ͡
ͧͧ͢͟͡ ͧͧ͢͟͡ ͦͣ͢͢͟ ͢͢͟͡͡ ͩͨ͢͟͡ ͩͪ͢͢͟ ͣͥ͢͢͟ ͩͪͨ͟ ͣ͢͟͢͢ ͧ͢͟͡͡ ͧ͢͟͡͡ ͣͩ͢͟͢ ͤͩ͢͟͡ ͤͩ͢͟͡ ͣͦͨ͢͟ ͧ͢͟͢͡ ͩͨͤ͟ ͣͩ͢͟͡ ͪͤͣ͟ ͪͤͣ͟ ͣͨͥ͢͟ ͪͧͣ͟ ͪͧͣ͟ ͤͥ͢͟͢ ͪͩͣ͟ ͩͤͤ͟ ͤͤͩ͢͟
ͨͦ
ͪͨ͟͡ ͩͪͨ͟ ͦ͢͢͟͡ ͨͣ͢͟͡ ͧͨͪ͟ ͩͨ͢͢͟ ͦͤ͢͢͟ ͤ͟͡͡ ͣͪ͢͟͡ ͪͦ͢͟ ͩͨͤ͟ ͣͧ͢͟͢ ͣ͢͢͟͡ ͧͧ͟͢ ͣͦͥ͢͟ ͩͩ͢͟͡ ͣͪͣ͟ ͣͨͨ͢͟ ͩͥͩ͟ ͩͤͤ͟ ͣͨ͢͟͢ ͪͤͨ͟ ͧͤ͟͢ ͤ͢͟͢͢ ͩ͢͟͡͡ ͣͨͪ͟ ͤͤͦ͢͟
ͩ͡
ͣ͢͢͟͡ ͣ͢͢͟͡ ͦͥ͢͢͟ ͪͣ͢͟͡ ͩͦ͟͢ ͪ͢͢͟͡ ͦͤ͢͢͟ ͦͦͨ͟ ͣͣ͢͟͢ ͪͦͦ͟ ͪͦͦ͟ ͣͪ͢͟͢ ͤ͢͟͡͡ ͩͣͩ͟ ͣͦͩ͢͟ ͩͩ͢͟͡ ͦͥͣ͟ ͣͩ͢͟͢ ͩͩͥ͟ ͩͩͥ͟ ͣͨͦ͢͟ ͪͦͥ͟ ͨͪ͟͡ ͤͦ͢͟͢ ͩ͢͟͡͡ ͦͩ͢͟ ͤͤͪ͢͟
ͩͦ
ͦ͢͟͡͡ ͦ͢͟͡͡ ͦͨ͢͢͟ ͨ͢͢͟͡ ͣͦ͢͟͡ ͪͥ͢͢͟ ͦ͢͢͟͡ ͨͨ͟͢ ͣͧ͢͟͢ ͪͪ͟͢ ͪͪ͟͢ ͣͣͤ͢͟ ͥͦ͢͟͡ ͪͪͨ͟ ͣͧͣ͢͟ ͩͦ͢͟͡ ͨͦ͟͡ ͣͩͦ͢͟ ͪͩ͢͟ ͪͩ͢͟ ͣͨͩ͢͟ ͪͧͩ͟ ͪͦͣ͟ ͤͪ͢͟͢ ͦ͢͟͡͡ ͨͧ͢͟ ͤͥͤ͢͟
ͪ͡
ͩͦ͢͟͡ ͩͦ͢͟͡ ͧ͢͢͟͢ ͪ͢͢͢͟ ͪ͢͢͢͟ ͪͨ͢͢͟ ͥͤ͢͢͟ ͪͤͪ͟ ͣͣ͢͟͡ ͣͤ͢͟͡ ͣͤ͢͟͡ ͣͣͨ͢͟ ͦͧ͢͟͡ ͦͧ͢͟͡ ͣͧͦ͢͟ ͨͪ͢͟͡ ͪͤ͢͟ ͣͩͪ͢͟ ͪͥͩ͟ ͪͥͩ͟ ͣͩͣ͢͟ ͪͨͩ͟ ͪͨͩ͟ ͤͣͤ͢͟ ͪͪͪ͟ ͩͨͣ͟ ͤͥͨ͢͟
ͨͦ
ͪͩͣ͟ ͪͣͧ͟ ͦͪ͢͢͟ ͩͧ͢͟͡ ͨ͟͢͡ ͪͦ͢͢͟ ͧͩ͢͢͟ ͤͪ͟͡ ͣͨ͢͟͢ ͪͣͨ͟ ͪ͟͢͡ ͣͣͥ͢͟ ͣͦ͢͟͡ ͧͩͣ͟ ͣͧͤ͢͟ ͣ͢͢͟͡ ͤ͟͢͡ ͣͩͧ͢͟ ͩͦͪ͟ ͩͦͪ͟ ͣͨͪ͢͟ ͪͥͪ͟ ͧͦ͟͢ ͤͪ͢͟͢ ͣ͢͟͢͡ ͣͩͨ͟ ͤͥͥ͢͟
ͩ͡
ͣͦ͢͟͡ ͣͦ͢͟͡ ͧͣ͢͢͟ ͧ͢͢͟͡ ͩͨͩ͟ ͪͪ͢͢͟ ͧͩ͢͢͟ ͦͨͦ͟ ͣͣ͢͟͢ ͪͧͨ͟ ͪͧͨ͟ ͣͣͩ͢͟ ͥͤ͢͟͡ ͩͦͥ͟ ͣͧͧ͢͟ ͣ͢͢͟͡ ͦͦͪ͟ ͣͪ͢͟͡ ͩͪͧ͟ ͩͪͧ͟ ͣͩͤ͢͟ ͪͧͧ͟ ͩͦ͢͟ ͤͣͤ͢͟ ͣ͢͟͢͡ ͦͤͥ͟ ͤͥͩ͢͟
ͩͦ
ͧͥ͢͟͡ ͧͥ͢͟͡ ͧͧ͢͢͟ ͣͣ͢͢͟ ͦͨ͢͟͡ ͣͣ͢͟͡ ͧͦ͢͢͟ ͨͪͦ͟ ͣͣͦ͢͟ ͥ͢͟͡͡ ͥ͢͟͡͡ ͣͤ͢͟͢ ͦͩ͢͟͡ ͣͪ͢͟͡ ͣͨ͢͟͡ ͪͪ͢͟͡ ͨͨͥ͟ ͣͪͥ͢͟ ͪͤ͟͡ ͪͤ͟͡ ͣͩͨ͢͟ ͪͩ͟͡ ͪͩ͟͡ ͤͣͨ͢͟ ͩ͢͢͟͡ ͨͤͩ͟ ͤͦͣ͢͟
ͪ͡
ͪͩ͢͟͡ ͪͩ͢͟͡ ͧͪ͢͢͟ ͤͥ͢͢͟ ͤͥ͢͢͟ ͣͧ͢͟͡ ͦͩ͢͢͟ ͪͧͩ͟ ͣͣͩ͢͟ ͤͨ͢͟͡ ͤͨ͢͟͡ ͣͤͦ͢͟ ͨ͢͟͡͡ ͨ͢͟͡͡ ͣͨͥ͢͟ ͪͤ͢͟͡ ͪͥͣ͟ ͣͪͩ͢͟ ͪͧ͟͡ ͪͧ͟͡ ͣͪ͢͟͡ ͪͪ͟͢ ͪͪ͟͢ ͤͤ͢͟͢ ͣ͢͢͟͡ ͩͪͪ͟ ͤͦͧ͢͟
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : kW) 5. SHC = Sensible Heat Capacity(Unit : kW) 6. PI = Power Input Comp + Outdoor Fan Motor (kW)
2-22
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Performance Data
table-6 Model No.:TN-C1508T00 Outdoor DB(̧) Indoor WB(̧) CFM DB(̧) 75 80 3520 85 90 75 80 3960 85 90 75 80 4400 85 90 75 80 4840 85 90 75 80 5280 85 90
Outdoor DB(̧) Indoor WB(̧) CFM DB(̧) 75 80 3520 85 90 75 80 3960 85 90 75 80 4400 85 90 75 80 4840 85 90 75 80 5280 85 90
TGC 115.9 120.9 125.5 129.6 121.3 126.6 131.3 135.6 124.5 129.9 134.8 139.2 126.7 132.1 137.1 141.6 128.3 133.8 138.9 143.4
TGC 105.5 110.1 114.2 118.0 110.4 115.2 119.5 123.5 113.3 118.2 122.7 126.7 115.3 120.3 124.8 128.9 116.8 121.8 126.4 130.6
61 SHC 88.9 102.1 111.9 117.9 94.9 109.0 119.4 123.5 101.9 117.0 122.8 126.8 106.7 120.3 124.9 129.0 110.1 121.9 126.5 130.6
61 SHC 91.6 105.2 115.3 121.4 97.7 112.2 123.0 129.5 104.9 120.5 132.0 139.1 109.8 126.1 137.1 141.6 113.3 130.1 138.9 143.4
PI 13.28 13.32 13.36 13.40 13.37 13.41 13.45 13.49 13.47 13.51 13.55 13.59 13.57 13.61 13.65 13.69 13.66 13.70 13.74 13.79
PI 10.61 10.64 10.67 10.70 10.70 10.73 10.76 10.79 10.79 10.82 10.85 10.89 10.88 10.91 10.95 10.98 10.97 11.01 11.04 11.07
TGC 116.7 118.8 120.5 121.8 122.1 124.3 126.1 127.4 125.3 127.6 129.4 130.8 127.5 129.8 131.6 133.0 129.1 131.4 133.3 134.8
105 67 SHC 69.3 86.8 104.5 116.1 73.9 92.6 111.5 123.9 79.4 99.4 119.7 133.0 83.1 104.1 125.3 136.9 85.7 107.4 129.3 138.6
TGC 128.2 130.5 132.3 133.8 134.1 136.5 138.5 140.0 137.7 140.1 142.2 143.7 140.0 142.5 144.6 146.2 141.8 144.4 146.5 148.0
PI 13.66 13.70 13.74 13.78 13.75 13.80 13.84 13.88 13.85 13.90 13.94 13.98 13.95 14.00 14.04 14.08 14.05 14.10 14.14 14.18
85 67 SHC 69.4 86.8 104.6 116.2 74.0 92.7 111.6 124.0 79.5 99.5 119.8 133.1 83.2 104.2 125.5 139.4 85.8 107.5 129.4 143.8
TGC 125.7 125.8 125.4 124.6 131.6 131.6 131.2 130.4 135.0 135.1 134.7 133.9 137.4 137.4 137.0 136.2 139.1 139.2 138.8 137.9
73 SHC 30.6 56.8 78.6 95.7 32.6 60.6 83.9 102.1 35.0 65.1 90.0 109.7 36.7 68.2 94.3 114.8 37.8 70.3 97.2 118.4
PI 10.94 10.97 11.01 11.04 11.03 11.07 11.10 11.13 11.13 11.16 11.20 11.23 11.22 11.26 11.29 11.32 11.32 11.35 11.39 11.42
PI 13.96 14.00 14.05 14.09 14.06 14.11 14.15 14.19 14.16 14.21 14.25 14.29 14.27 14.31 14.35 14.40 14.37 14.41 14.45 14.50
TGC 137.8 137.8 137.5 136.6 144.2 144.2 143.8 143.0 148.0 148.1 147.7 146.8 150.5 150.6 150.2 149.3 152.5 152.5 152.1 151.2
TGC 99.3 103.6 107.5 111.0 103.9 108.4 112.5 116.2 106.7 111.3 115.5 119.3 108.5 113.2 117.5 121.3 109.9 114.6 119.0 122.9
61 SHC 89.7 103.1 107.5 111.0 95.7 108.4 112.5 116.2 102.8 111.3 115.5 119.3 107.6 113.2 117.5 121.3 109.9 114.6 119.0 122.9
73 SHC 30.6 56.9 78.7 95.8 32.7 60.7 83.9 102.2 35.1 65.2 90.1 109.8 36.7 68.2 94.4 114.9 37.9 70.4 97.3 118.5
PI 14.78 14.83 14.87 14.91 14.88 14.93 14.97 15.02 14.99 15.03 15.08 15.12 15.09 15.13 15.18 15.22 15.19 15.23 15.28 15.33
PI 11.14 11.18 11.21 11.24 11.24 11.27 11.31 11.34 11.34 11.37 11.40 11.44 11.43 11.47 11.50 11.54 11.53 11.56 11.60 11.63
TGC 109.8 111.7 113.3 114.6 114.9 116.9 118.6 119.9 117.9 120.0 121.8 123.1 119.9 122.1 123.9 125.2 121.5 123.5 125.4 126.8
115 67 SHC 68.0 85.1 102.5 113.9 72.5 90.8 109.4 119.9 77.9 97.5 117.4 123.1 81.5 102.1 122.9 125.2 84.1 105.3 125.4 126.8
TGC 111.8 116.7 121.1 125.0 117.0 122.1 126.7 130.9 120.1 125.3 130.1 134.3 122.2 127.5 132.3 136.6 123.8 129.1 134.0 138.4
PI 15.25 15.29 15.34 15.39 15.35 15.40 15.45 15.49 15.46 15.50 15.55 15.60 15.56 15.61 15.66 15.70 15.67 15.70 15.76 15.81
61 SHC 93.3 107.2 117.5 123.7 99.6 114.3 125.3 130.9 106.9 122.8 130.1 134.3 111.9 127.5 132.3 136.6 115.5 129.1 134.0 138.4
TGC 118.0 118.1 117.7 117.0 123.5 123.6 123.2 122.5 126.8 126.8 126.5 125.7 128.9 129.0 128.6 127.9 130.6 130.7 130.3 129.5
73 SHC 30.0 55.7 77.1 93.9 32.0 59.5 82.3 100.2 34.4 63.9 88.3 107.6 36.0 66.9 92.5 112.6 37.1 69.0 95.4 116.2
PI 11.70 11.73 11.77 11.80 11.79 11.83 11.86 11.90 11.93 11.96 12.00 12.03 11.97 12.01 12.05 12.08 12.07 12.10 12.14 12.17
PI 15.53 15.58 15.62 15.67 15.64 15.68 15.73 15.78 15.74 15.79 15.84 15.89 15.85 15.90 15.95 15.99 15.96 16.01 16.05 16.10
TGC 123.6 125.9 127.7 129.0 129.4 131.7 133.6 135.0 132.8 135.2 137.2 138.6 135.1 137.5 139.5 141.0 136.8 139.3 141.3 142.8
TGC 92.0 95.9 99.6 102.8 96.2 100.4 104.2 107.6 98.8 103.1 107.0 110.5 100.5 104.8 108.8 112.4 101.8 106.2 110.2 113.8
61 SHC 85.6 95.9 99.6 102.8 91.4 100.4 104.2 107.6 98.1 103.1 107.0 110.5 100.5 104.8 108.8 112.4 101.8 106.2 110.2 113.8
95 67 SHC 70.7 88.5 106.6 118.4 75.4 94.4 113.7 126.4 81.0 101.4 122.1 135.7 84.8 106.2 127.9 141.0 87.4 109.5 131.9 142.8
PI 15.46 15.51 15.56 15.60 15.57 15.61 15.66 15.71 15.67 15.71 15.76 15.81 15.77 15.82 15.86 15.91 15.87 15.92 15.97 16.01
PI 12.07 12.10 12.14 12.18 12.16 12.20 12.24 12.27 12.30 12.34 12.38 12.41 12.35 12.39 12.43 12.46 12.45 12.48 12.52 12.56
TGC 101.7 103.5 105.0 106.1 106.4 108.3 109.9 111.1 109.2 111.2 112.8 114.0 111.1 113.1 114.7 115.9 112.5 114.5 116.2 117.4
TGC 132.9 133.0 132.6 131.8 139.1 139.2 138.8 137.9 142.8 142.9 142.5 141.6 145.2 145.3 144.9 144.0 147.1 147.2 146.7 145.9
125 67 SHC 64.9 81.2 97.8 106.1 69.2 86.7 104.4 111.1 74.3 93.0 112.1 114.0 77.8 97.4 114.7 115.9 80.2 100.5 116.2 117.4
PI 15.95 16.00 16.05 16.10 16.06 16.10 16.15 16.20 16.16 16.21 16.26 16.31 16.27 16.32 16.36 16.41 16.37 16.42 16.47 16.52
73 SHC 31.2 58.0 80.2 97.6 33.3 61.8 85.5 104.2 35.7 66.4 91.9 111.9 37.4 69.5 96.2 117.1 38.6 71.7 99.2 120.8
TGC 109.3 109.4 109.0 108.4 114.4 114.4 114.1 113.4 117.4 117.5 117.1 116.4 119.4 119.5 119.1 118.4 121.0 121.0 120.7 119.9
PI 12.29 12.33 12.37 12.40 12.39 12.42 12.46 12.50 12.53 12.57 12.61 12.64 12.58 12.62 12.66 12.69 12.68 12.71 12.75 12.79
73 SHC 28.6 53.2 73.6 89.6 30.5 56.8 78.5 95.6 32.8 60.9 84.3 102.6 34.3 63.8 88.2 107.5 35.4 65.8 91.0 110.8
PI 16.25 16.30 16.34 16.39 16.35 16.40 16.45 16.50 16.46 16.51 16.56 16.61 16.57 16.62 16.67 16.72 16.68 16.73 16.78 16.83
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
7.5-12.5RT
Ducted Split
2-23
TA5CUN2-01A
Performance Data
. . Performance data 9 Evaporator Fan Performance TN-C0908T00 (English)
Table-7
External Static Pressure(in.Aq.) CFM
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2360
358 0.23 381 0.29 406 0.35 428 0.41 453 0.47 475 0.53 498
2580
386 0.29 415
0.58 523 0.63 549 0.69 578 0.76 609 0.82 641
0.89
0.35 446 0.41 473 0.47 503 0.53 538 0.59 572 0.64 607 0.70 639 0.76 672 0.82 705 0.89 739 0.96
2800
416 0.38 468 0.43 522 0.47 567 0.52 609 0.57 645 0.62 678 0.68 709 0.75 743 0.82 779 0.89 811 0.96 849
3020
481 0.48 522
3240
578 0.58 561 0.64 589 0.70 632 0.78 667 0.85 698 0.94 733 1.01 769 1.10
0.52 564 0.58 606 0.64 644 0.70 678 0.77 711 0.84 746 0.92 780 0.99 816 1.08 852 801 1.17 838 1.25 875
1.02
1.15 895
1.23
1.33 911
1.42
1Hp STANDARD MOTOR & DRIVE 2Hp OVER SIZED MOTOR & DRIVE
Fan motor heat(kW)= 3.26 x Fan BHP Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Evaporator Fan Performance TN-C0908T00 (SI)
Table-8
External Static Pressure(mmAq.) l/s
2.5
5.1
7.6
10.2
12.7
15.2
17.8
20.3
22.9
25.4
27.9
30.5
RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW 1114
358 0.17 381 0.22 406 0.26 428 0.31 453 0.35 475 0.40 498 0.43 523 0.47 549 0.51 578 0.57 609 0.61 641
0.66
1218
386 0.22 415
0.72
1321
416 0.28 468 0.32 522 0.35 567 0.39 609 0.43 645 0.46 678 0.51 709 0.56 743 0.61 779 0.66 811
0.72 849
1425
481 0.36 522
0.39 564 0.43 606 0.48 644 0.52 678 0.57 711 0.63 746 0.69 780
0.74 816 0.81 852
0.86 895 0.92
1529
578 0.43 561 0.48 589 0.52 632 0.58 667 0.63 698 0.70 733 0.75 769 0.82 801
0.87 838 0.93 875
0.99 911 1.06
0.26 446 0.31 473 0.35 503 0.40 538 0.44 572 0.48 607 0.52 639 0.57 672 0.61 705 0.66 739
0.76
1Hp STANDARD MOTOR & DRIVE 2Hp OVER SIZED MOTOR & DRIVE
Fan motor heat(MBH)= 1.28 x Fan BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Table-9
Fan speed Data TN-C0908T00(RPM)
0 Turn Open 1 Turn Open 2 Turn Open 3 Turn Open 4 Turn Open 5 Turn Open 6 Turn Open Standard Motor & Drive Fan Speed
667
643
621
601
573
549
520
Over size Motor & Drive Fan Speed
787
759
735
711
682
655
631
Factory set at 3 turns open.
2-24
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Performance Data
. . Performance data 9 Table-10 CFM
Evaporator Fan Performance TN-C1208T00 (English)
External Static Pressure(in.Aq.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2880
566 0.51 583 0.55 601 0.59 618 0.63 645 0.67 673 0.70 709 0.73 743 0.77 772 0.81 800 0.84 831 0.88 860 0.94
3240
593 0.59 608 0.63 627 0.68 649 0.73 672 0.78 695 0.84 721 0.89 748 0.95 773 1.02 801 1.09 829 1.17 854 1.25
3600
608 0.85 635 0.88 668 0.91 701 0.96 735 1.03 762 1.09 793 1.16 824 1.21 855 1.25 886 1.30 915 1.35 946 1.41
3960
648 0.98 667 1.01 681 1.05 703 1.09 725 1.13 759 1.17 795 1.22 832 1.27 869 1.33 903 1.39 939
1.45 974 1.50
4320
665 1.05 683 1.09 707 1.13 731 1.17 760 1.22 791 1.27 822 1.33 853 1.39 886
1.62 987 1.70
CFM
External Static Pressure(in.Aq.) 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2880
892 0.99 824 1.05 857 1.10 891
1.17 925
3240
881 1.33 913 1.41 945 1.49 973
1.57 1001 1.66 1030 1.77 1061 1.88 1092 1.98
3600 977
1.46 919 1.54 953
2Hp STANDARD MOTOR & DRIVE 2Hp STANDARD MOTOR & HIGH STATIC DRIVE 3Hp OVER SIZED MOTOR & DRIVE
1.23 957 1.29 992 1.34 1028 1.41
1.47 1009 1.54 1042 1.62 1076 1.70 1108 1.77 1142 1.85 1178 1.94 1213 2.04
3960 1009 1.55 1045 1.61 1093 1.68 1142 1.74 1186 1.85 1225 1.89 1264 1.97 1303 2.06 4320 1020 1.78 1053 1.86 1099 1.97 1148 2.08 1193 1.89 1229 2.29 1278 2.40 1318 2.52
Fan motor heat(MBH)= 3.1 x Fan BHP Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
7.5-12.5RT
Ducted Split
2-25
Performance Data
TA5CUN2-01A
9. Performance data Evaporator Fan Performance TN-C1208T00 (SI)
Table-11 l/s
External Static Pressure(mmAq.) 2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4 27.9 30.5 RPM BKW RPM BKW RPM BKW RPM BKWRPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW
1358
566 0.38 583 0.41 601 0.44 618 0.47 645 0.50 673 0.52 709 0.54 743 0.57 772 0.60 800 0.63 831 0.66 860 0.70
1528
593 0.44 608 0.47 627 0.51 649 0.54 672 0.58 695 0.63 721 0.66 748 0.71 773 0.76 801 0.81 829 0.87 854 0.93
1698
608 0.63 635 0.66 668 0.68 701 0.72 735 0.77 762 0.81 793 0.87 824 0.90 855 0.93 886 0.97 915 1.01 946 1.05
1868
648 0.73 667 0.75 681 0.78 703 0.81 725 0.84 759 0.87 795 0.91 832 0.95 869 0.99 903 1.04 939
1.08 974 1.12
2038
665 0.78 683 0.81 707 0.84 731 0.87 760 0.91 791 0.95 822 0.99 853 1.04 886
1.21 987 1.27
External Static Pressure(mmAq.) 33 35.6 38.1 40.6 43.2 45.7 48.3 50.8 RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW RPM BKW
l/s
1358
892 0.74 824 0.78 857 0.82 891
1528
881 0.99 913 1.05 1698 977 1.10 1009 1.15 1868 1009 1.16 1045 1.20 2038 1020 1.33 1053 1.39
945 1.11 973
1.09 919 1.15 953
2Hp STANDARD MOTOR & DRIVE 2Hp STANDARD MOTOR & HIGH STATIC DRIVE 3Hp OVER SIZED MOTOR & DRIVE
0.87 925 0.92 957 0.96 992 1.00 1028 1.05 1.17 1001 1.24 1030 1.32 1061 1.40 1092 1.48
1042 1.21 1076 1.27 1108 1.32 1142 1.38 1178 1.45 1213 1.52 1093 1.25 1142 1.30 1186 1.35 1225 1.41 1264 1.47 1303 1.54 1099 1.47 1148 1.55 1193 1.63 1229 1.71 1278 1.79 1318 1.88
Fan motor heat(kW)= 1.22 x Fan BkW Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Table-12
Fan speed Data TN-C1208T00(RPM)
0 TURN OPEN
1 TURN OPEN 2 TURN OPEN 3 TURN OPEN 4 TURN OPEN 5 TURN OPEN 6 TURN OPEN
Standard Motor & Drive Fan Speed
872
839
805
782
739
701
668
Standard Motor & High Static Drive Accessory Fan Speed
1108
1059
1013
970
931
897
859
Over Sized Motor & Drive Fan Speed
1271
1213
1152
1092
1037
973
916
Factory set at 3 turns open.
2-26
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Performance Data
9. Performance data Table-13 CFM
Evaporator Fan Performance TN-C1508T00 (English)
External Static Pressure(in.Aq.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3520
624 1.09 647 1.15 669 1.22 691 1.29 713 1.36 735 1.43 757 1.50 779 1.57 801 1.64 824 1.71 846 1.78 868 1.85
3960
673 1.45 695 1.52 717 1.59 739 1.66 761 1.73 783 1.80 805 1.87 828 1.94 850 2.01 872 2.08 894 2.15 916 2.22
4400
726 1.89 749 1.96 771 2.03 793 2.10 815 2.17 837 2.24 859 2.31 881 2.38 903 2.45 926 2.52 948 2.59 970 2.66
4840
786 2.40 808 2.46 830 2.53 852 2.6 0 874 2.67 897 2.74 919 2.81 941 2.88 963 2.95 985 3.02 1007 3.09 1029 3.16
5280
851 2.97 873 3.04 895 3.11 917 3.18 940 3.25 962 3.32 984 3.39 1006 3.46 1028 3.53 1050 3.60 1072 3.67 1094 3.74
CFM
External Static Pressure(in.Aq.) 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3520
890 1.92 912 1.99 934 2.06 956 2.13 978 2.20 1001 2.27 1023 2.34 1045 2.41
3960
938 2.29 960 2.36 982 2.43 1005 2.50 1027 2.57 1049 2.64 1071 2.71 1093 2.78
4400
992 2.73 1014 2.80 1036 2.87 1058 2.94 1080 3.01 1103 3.08 1125 3.15 1147 3.22
4840
1051 3.23 1074 3.30 1096 3.37 1118 3.44 1140 3.51 1162 3.58 1184 3.65 1206 3.72
5280
1117 3.81 1139 3.88 1161 3.95 1183 4.02 1205 4.09 1227 4.16 1249 4.23 1271 4.30
2Hp STANDARD MOTOR & DRIVE 2Hp STANDARD MOTOR & HIGH STATIC DRIVE 3Hp OVER SIZED MOTOR & DRIVE
• Fan motor heat(MBH)= 3.1 x Fan BHP • Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
7.5-12.5RT
Ducted Split
2-27
Performance Data
TA5CUN2-01A
9. Performance data Table-14
l/s
Evaporator Fan Performance TN-C1508T00 (SI)
External Static Pressure(mmAq.) 2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4 27.9 30.5 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW
1661
624 0.81 647 0.86 669 0.91 691 0.97 713 1.02 735 1.07 757 1.12 779 1.17 801 1.23 824 1.28 846 1.33 868 1.38
1869
673 1.08 695 1.14 717 1.19 739 1.24 761 1.29 783 1.34 805 1.40 828 1.45 850 1.50 872 1.55 894 1.60 916 1.66
2077
726 1.41 749 1.46 771 1.51 793 1.56 815 1.62 837 1.67 859 1.72 881 1.77 903 1.83 926 1.88 948 1.93 970 1.98
2284
786 1.79 808 1.84 830 1.89 852 1.94 874 1.99 897 2.05 919 2.10 941 2.15 963 2.20 985 2.25 1007 2.31 1029 2.36
2492
851 2.22 873 2.27 895 2.32 917 2.37 940 2.43 962 2.48 984 2.53 1006 2.58 1028 2.64 1050 2.69 1072 2.74 1094 2.79
l/s
External Static Pressure(mmAq.) 33.0 35.6 38.1 40.6 43.2 45.7 48.3 50.8 RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW
1661
890 1.43 912 1.49 934 1.54 956 1.59 978 1.64 1001 1.69 1023 1.75 1045 1.80
1869
938 1.71 960 1.76 982 1.81 1005 1.87 1027 1.92 1049 1.97 1071 2.02 1093 2.07
2Hp STANDARD MOTOR & DRIVE 2Hp STANDARD MOTOR & HIGH STATIC DRIVE 3Hp OVER SIZED MOTOR & DRIVE
2077
992 2.03 1014 2.09 1036 2.14 1058 2.19 1080 2.24 1103 2.29 1125 2.35 1147 2.40 2284 1051 2.41 1074 2.46 1096 2.52 1118 2.57 1140 2.62 1162 2.67 1184 2.72 1206 2.78 2492 1117 2.84 1139 2.90 1161 2.95 1183 3.00 1205 3.05 1227 3.10 1249 3.16 1271 3.21
• Fan motor heat(kW)= 1.22 x Fan BkW • Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Table-15
Fan speed Data TN-C1508T00(RPM)
0 TURN OPEN Standard Motor & Drive Fan Speed
1 TURN OPEN 2 TURN OPEN 3 TURN OPEN 4 TURN OPEN 5 TURN OPEN 6 TURN OPEN
861
821
780
740
700
660
620
Standard Motor & High Static Drive Accessory Fan Speed
1046
998
949
900
852
803
754
Over Sized Motor & Drive Fan Speed
1314
1253
1192
1131
1070
1009
947
• Factory set at 3 turns open.
2-28
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Performance Data
9. Performance data Table-16 Model No.
Accessory Static Pressure Drops
CFM
l/s
Standard Filter in.Aq. mm Aq.
TN-C0908T00 TN-C1208T00 TN-C1508T00
7.5-12.5RT
2720 3600 4080 3520 4400 5280
1284 1699 1925 1661 2076 2492
0.06 0.10 0.14 0.08 0.13 0.18
1.52 2.54 3.56 2.03 3.30 4.57
Ducted Split
2-29
TA5CUN2-01A
Electrical Data
10. Electrical Data Electrical Data, Cooling
Table-17
Standard indoor fan motor *M.F.S.
RT
MODEL
Unit Operating Voltage Range
*M.C.A.
7.5
TN-C0908T00
342~456
20.0
25
25
10
TN-C1208T00
342~456
30.0
35
35
12.5
TN-C1508T00
342~456
25.0
45
45
*M.C.B
Note: *M.C.A.: Minimum Circuit Ampacity *M.F.S.: Maximum Fuse Size *M.C.B.: Maximum Circuit Breaker
Table-18 MODEL
Electrical Characteristics --- Evaporator Fan Motor --- 50 Hz Standard indoor fan motor Phase
No
Volts
TN-C0908T00
1
380-415
TN-C1208T00
1
TN-C1508T00
1
Table-19 MODEL
3
1
2.3
380-415
3
2
3.4
380-415
3
2
3.4
COMPRESSOR HP Phase
FLA
LRA
No
3
4.5
6.5
51
1
220-240
1
0.2
1.4
380-415
3
6
9.3
73
2
220-240
1
0.2
1.4
380-415
3
6
9.2
79
4
220-240
1
0.2
1.4
Volts
TN-C0908T00
2
380-415
TN-C1208T00
2
TN-C1508T00
2
2-30
FLA
Electrical Characteristics --- Compressor and Outdoor Fan Motor --- 50 Hz
No
Note:
HP
OUTDOOR FAN MOTOR HP Volts Phase
FLA
FLA -Full Load Amps. LRA- Locked Rotor Amps.
Ducted Split
7.5-12.9RT
Temperature,Pressure Chart
TA5CUN2-01A
7HPSHUDWXUH 3UHVVXUH &KDUW 0RGHO 1R 71 & 7 €&
/RZ 3UHVVXUH .J FP
'LVFKDUJH $LU 7HPS '% &
€&
NJ FP
2XWGRRU 7HPS '% &
'LVFKDUJH $LU 7HPSHUDWXUH & /RZ 3UHVVXUH .J FP
0RGHO 1R 71 & 7 €&
/RZ 3UHVVXUH .J FP
'LVFKDUJH $LU 7HPS '% &
€&
NJ FP
2XWGRRU 7HPS '% &
'LVFKDUJH $LU 7HPSHUDWXUH & /RZ 3UHVVXUH .J FP
7.5-12.5RT
Ducted Split
2-31
TA5CUN2-01A
Temperature,Pressure Chart
11. Temperature, Pressure Chart Model No. : TN-C1508T00 (ÛC) 22
9
21 20
8
19
7
17 16 15
6
14 13 12
5
11 10
4
9
Low Pressure(Kg/cm2)
Discharge Air Temp. DB(°C)
18
8 3
7 21ÛC
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53 (kg/cm2)
Outdoor Temp. DB(°C) : Discharge Air Temperature, °C : Low Pressure, Kg/cm2
2-32
Ducted Split
7.5-12.5RT
TA5CUN2-01A
Refrigerant Cycle Diagrams
12. Refrigerant Cycle Diagrams Model No.: TN-C0908T00,TN-C1208T00 OUTDOOR COIL
INDOOR COIL
BY-PASS HI-PRESSURE SWITCH SERVICE VALVE DISCHARGE LINE
SUCTION LINE
COMPRESSOR BY-PASS
HI-PRESSURE SWITCH SERVICE VALVE DISCHARGE LINE SERVICE COMPRESSOR VALVE
SUCTION LINE
CAPILLARY TUBE
SERVICE VALVE
CAPILLARY TUBE Note: : Cooling
Model No.: TN-C1508T00 SERVICE VALVE
CAPILLARY TUBE
INDOOR COIL
OUTDOOR COIL
HI-PRESSURE SWITCH
SERVICE VALVE
COMPRESSOR
Note: : Cooling
7.5-12.5RT
Ducted Split
2-33
Operation Range
TA5CUN2-01A
13. 2SHUDWLRQ 5DQJH &RROLQJ
2XWGRRU 8QLW > & '%@
&RQWLQXRXV RSHUDWLRQ
,QGRRU 8QLW > & '%@ $OWKRXJK ORZ DPELHQW NLW LV LQVWDOOHG LQ FDVH RXWGRRU WHPSHUDWXUH JRHV EHORZ & WKH FRROLQJ FDSDFLW\ FDQ EH GURSSHG DQG RSHUDWLRQ FKDUDFWHULVWLFV FDQ EH VOLJKWO\ GLIIHUHQW
2-34
Ducted Split
7.5-12.5RT
Operating Space Limitations
TA5CUN2-01A
14. Operating Space Limitations 14.1 Indoor units
More than 910mm
More than 600mm
More than 600mm
More than 1000mm
Apply for 7.5
More than 910mm
More than 1000mm
Apply for 12.5RT
10RT
14.2 Outdoor units
more than 900mm more than 900mm
more than 900mm more than 900mm
more than 900mm
more than 900mm
TN-C0908T00
more than 910mm
more than 910mm
TN-C1208T00
more than 910mm
more than 910mm
TN-C1508T00 7.5-12.5RT
Ducted Split
2-35
Coefficient of Capacity Change
TA5CUN2-01A
15. The Coefficient of Capacity Change
Cap ac i t y (%)
100
LN-0380CC(25m) LN-0480CC/0580CC
90
TN-C0908T00,TN-C1208T00 TN-C1508T00
80
70 7.5
10
20
30
40
50
Total pipe length(m)
Model
Pipe Size (Diameter:Ă˜)
Length(m)
Elevation(m)
Additional refrigerant Cycle No
Gas
Liquid
Standard
Max.
Standard
Max.
(g/m)
TN-C0908T00
3/4"
1/2"
7.5
50
7.5
30
60
2
TN-C1208T00
3/4"
1/2"
7.5
50
7.5
30
60
2
TN-C1508T00
9/8"
5/8"
7.5
50
7.5
30
80
2
*If TN-C0908T00 Model is installed at a distance of 50m, 2 550g of refrigerant should be added (50-7.5) x 60g=2 550g *Capacity is based of standard length and maximum allowance length is on the basis of reliability. Notes: * Equivalent pipe length= Actual pipe length + number of bend x 0.3
2-36
Ducted Split
7.5-12.5RT
Mechanical Specifications
TA5CUN2-01A
16. Mechanical Specifications Mec hanical Specifications General Air handling units shall be completely factory asembled including coil drain pan, Blower motor and controls in an insulated casing that can be applied in horizontal or vertical configuration. Units shall be rated in accordance with ARI standard testing procedure, fully changed with R22. Units shall fully factory tested before shipment.
Casing Unit casing shall be constructed of having gauge zinc coated, galvanized steel. The cabinet shall be exterior painted and weather resistance. The condensing units shall have a water and air tight service panels with minimum number of screws per panel for easy servicing.
Compressors LG Ducted Split System units shall have direct drive hermetic compressor, reciprocating type with internal built in lubricating mechanism for all moving parts. Motor shall be suction gas cooled with internal temperature and over current sensitive motor over load, for maximum protection. Factory rubber shock mounted and internally spring isolation for sound and vibration control.
Refrigerant Circuits Each refrigerant circuit shall have an independent fixed capillary tube devices and service pressure ports, and refrigerant line filter(factory-installed) as standard.
Evaporator and Condenser Coils Shall be aluminum plate fins, mechanically bonded to copper tubes. Coil shall be factory tested for leakage and pressure.
Outdoor Fans Statically and dynamically, direct drive outdoor fan in vertical discharge position(Except 3RT). Permanently lubricated fan motors with built in thermal overload protection.
Indoor Fan Direct drive indoor fan for over 15RT units with forward curve centrifugal fans. Belt drive indoor fan for all models above 7.5RT. All motors shall be thermally overload protected.
Controls All units shall be controlled by thermostat. Time delay PCB shall provide time delay between Fan and Compressor.
7.5-12.5RT
Ducted Split
2-37
TA5CUN2-01A
Function of Remote Control
17. Function of Remote Control LCD Wired Remote Control(For above 7.5 RT Models)
AUTO SWING
OPERATION
SET TEMP
SUB FUNCTION
Room Temp
1
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4
HI MED LO
Time Timer
Operation unit
On Off Set no. Time 01
03
Program set 05
07
09
11
13
15
17
19
21
23
3 17 6 7 8 9 10 11 12
2 4 Timer
Cancel
Program
Week
Hour
Min
5 Holiday
15
SET/CLR RESET
13
1. Operation display Displays the operation conditions. 2. On/Off Button Operation starts when this button is pressed, and stops when the button is pressed again. 3. Set Temperature Button Used to set the temperature when the desired temperature is obtained. 4. FAN Operation Button Used to circulate room air without cooling or heating. 5. Operation Mode Selection Button Used to select the operation mode. • Auto Operation Mode. • Cooling Operation Mode. • Soft Dry Operation Mode. 6.Electric Heater Button (HEAT PUMP MODEL ONLY) Used to set the Electric Heater.
14 16
9. Week Button Used to set a day of the week. 10. Program Button Used to set the weekly timer. 11. Holiday Button Used to set a holiday of the week. 12. Time Set Button Used to set the time of the day and change the time in the weekly timer Function. 13. Set and Clear Button Used to set and clear the weekly timer. 14. Room Temperature Checking Button Used to check the room temperature. 15. Humidity Button 16. Reset Button Used to set the current time and clear the setting time. 17. Operation Indicator
7. Timer Cancel Button Used to cancel the timer. 8. Timer Set Button Used to set the timer when the desired time is obtained.
2-38
Ducted Split
7.5-12.5RT
Part 3 15~20RT
1. Models List ......................................................................................................................2 2. Model Number Nomenclature ..........................................................................................3 3. Feature & Benefits ...........................................................................................................4 4. List of Functions ...............................................................................................................8 5. Specifications ................................................................................................................. 9 6. Dimensional Drawings ...................................................................................................10 7. Type of Applications .......................................................................................................12 8. Wiring Diagrams.............................................................................................................13 9. Performance Data ........................................................................................... .............15 10. Electrical Data ..............................................................................................................23 11. Temperature, Pressure Chart.......................................................................................24 12. Refrigerant Cycle Diagrams .........................................................................................25 13. Operation Range..........................................................................................................26 14. Operating Space Limitations ........................................................................................27 15. The coefficient of Capacity Change .............................................................................28 .. .......................................................................................29 16. Mechanical Specifications .. .......................................................................................30 17. Function of Remote control
Ducted Split
3-1
TA5CUN2-01A
Models List
1. Models List 1.1 Cooling Only Nominal Capacity RT
Power Supply
Model Refrigerant
15
Model Name TN-C1808T00
3Ø, 380-415V, 50Hz
R22 20
3-2
Ø, V, Hz
TN-C2408T00
Ducted Split
TA5CUN2-01A
Models Nomenclature
2. Model Number Nomenclature T N - C 1 8
0 8 T 0 0
Development Sequence Model Type 0:Gold Fin(Over 5RT) B: Basic
Outdoor Fan Discharge S: Side Discharge T: Top Discharge Electric Standard (Volts / Freq. / Phase) 8 : 380-415V / 50Hz / 3Ă˜ Cooling Capacity 180 : 180 000 Btu/h 240 : 225 000 Btu/h
Model Type C: Cooling Only H: Heat Pump
Type of Air Conditioner TN: LGETA Ducted Split Air Conditioner
Ducted Split
3-3
TA5CUN2-01A
Features & Benefits
3. Features & Benefits
This range of LG units are suitable for high static requirement s used for light commercial & commercial application. The Units are completely assembled, piped and wired in the factory. The indoor and outdoor units are separately packed & shipped. Each unit has been tested for pressure and has a holding charge of R22 for storage and for shipping. The compact design, quiet operation and higher cooling capacity makes the condensing units suitable for any outdoor location. Light Weight air-handlers make them suitable for ceiling application. All shipped metal parts are made of commercial grade galvanized steel. After fabrication, each part is cleaned & coated with baked enamel paint. A complete line of high static blower units are available for precise capacity of application. All indoor units are equipped with micro-processor controlled wired remote controller.
Easy installation LG ducted split units provide many time and money saving features. Micom Control Time delay relay, anti-short-cycle timer no more required with micom control. Initial cost saving, since the functions of these parts are the main feature of micom control.
Easy access remote controller Remote controller has 3 wires only. This is another cost and time saving installation feature. The wiring of low voltage to the unit and remote controller is easy as brown-brown, red-red, yellow-yellow connections. This simplified system makes it easier for the installer to attach.
Compact and light weight design
3-4
Ducted Split
TA5CUN2-01A
Features & Benefits
Durable, dependable components Waterproof cabinets are constructed of galvanized steel with powder coated painting. Compact size enables the unit to be located where space is limited. Condenser fin guard is designed for safety against sharp edge of outdoor coil. Micom Control - Reduce the number of components to operate the unit . - Component failure is reduced. - Cooling mode controlled by Micom control through input signal from indoor and outdoor temperature sensor. - Field installed anti short cycle timer and time delay relay not required with micom control. - Humidifier can be controlled by micom control.
Tight Top Cover and Cabinet - The units incorporate two or three layers top cover. The two or three piece layers overlaps in such a way that water cannot leak into the unit. These overlapped edges are gasketed and sealed to ensure superior water integrity.
Micom Control • Gradual power supply for fans, compressor and heater by staging through micom control. • In case of power failure, Micom control remembers the previous running condition before power failure. The unit will start again in previous mode when power re-energized.
Product quality and reliability • LG Ducted split unit have been rigorously life tested at the factory for more than 1 500 hours. • All of LG Outdoor units were rigorously rain tested at the factory to ensure water tight integrity. • Actual shipping tests are performed to determine the best packing. Units are shipped around the country to obtain the best packaging test result. These test assure that the unit will arrive at your job site in best condition. • We perform 100% coil leak test at the factory. The indoor coil and outdoor coils are leak tested at 200psig and pressure tested to 500psig respectively. • Every unit goes full run test to meet LG standards requirements. • Before units are shipped, 5 units which are selected by sampling undergo STLT(Short Time Life Test) are for more than 300 hours. • All LG Ducted split units undergo overload cooling tested(ambient temp is 129°F). In this condition, units operated continuously without any problem.
Ducted Split
3-5
Features & Benefits
TA5CUN2-01A
Basic & Optional Features Cooling & Fan Operation : - LG ducted split air conditioners can provide cooling & fan operation. In the cooling mode, it cools the air with an operation range of 18~30°C. In the fan operation mode, only indoor fan at the selected speed will run, outdoor fan and compressor will be off.
Self Diagnosis Function: - This function provides diagnosis of the unit. An error code will be displayed on the LCD wired remote controller & diagnosis can be done as per the code indication. The same is also printed on key cover of the LCD wired remote controller.
Gold Fin TM Anti Corrosion
[Salt spray test for 15 days]
- LG’s Outdoor Heat Exchanger is coated with a golden anti-corrosive epoxy treatment on the aluminum coil to
After 15 days
LG Gold Fin ™ Anti Corrosion
After 15 days
Conventional starting to corrode
minimized corrosion. This maintains heat transfer properties of the coil for an extended time where as non-
Gold fin
Gold Fin coils progressively lose efficiency due to surface corrosion. Standard on every LG air conditioner, This assists in areas suffering from pollution or near the ocean where the unit may subjected to higher levels of salt.
Uncoated aluminum
Wired Remote Control: - It can control all the functions of the unit. You can c h e c k / s e t t e m p e r a t u r e , s e t t i m e r, h o l i d a y & a l s o diagnose the error of the unit. It also has the option of weekly program.
Weekl y Pr ogram: -It provides on/off schedule of operation for a period of one week.
Time Delay Safety Function: -It delays restarting of the compressor by three minutes preventing any damage to the compressor.
3-6
Ducted Split
Features & Benefits
TA5CUN2-01A
Child Lock Function: -It prevents the children or others from tampering with the control buttons. Unit can be controlled by the wireless remote controller. This can be easily set by pressing timer key & Min key simultaneously. After child lock is set, pressing any key will display CL on
CHILD LOCK -Display
the LCD for 3 seconds and all the keys are ineffecProduct Data
tive.
Ducted Split
3-7
List of Functions
TA5CUN2-01A
4. List of Functions Model No.
TN-C1808T00
TN-C2408T00
Cooling & Fan Operation
O
O
Auto Restart Operation
O
O
Wired Remote Control
O
O
Group Control
-
-
Child Lock Function
O
O
Self Diagnosis Function
O
O
W eekly Program
O
O
Time Delay safety
O
O
Two Thermistor Control
-
-
Central Control
-
-
Zone Control
-
-
Energy Saving Gold Fin
O -
O -
Option -
Option -
-
-
Low Pressure Switch
O
O
High Pressure Switch
O
O
Phase Protection
O
O
Features
W ireless Remote Control Electric Heater Fire Alarm Function Electronic Thermostat
Notes: O :Applied
- :Not applied
* Option : Model name & price are different according to options, and assembled in factory with main unit. * Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
3-8
Ducted Split
Specifications
TA5CUN2-01A
5. Specifications Nominal RT
(RT)
Models Gross Cooling Capacity Capacity
Net Cooling Capacity Net Heating Capacity
Electrical Data
Power Input
kW
53.54
67.41
Btu/h
182,700
230,000
kW
52.75
65.94
Btu/h
180,000
225,000
kW
-
-
Btu/h
3/380ѝ415/50 38
Ø / V / Hz Cooling
A
36
Heating
A
-
-
Cooling
W
21,000
22,500
Heating
W
-
-
CFM
5300
7000
EER
Btu/h.W
8.57
10.00
SEER
Btu/h.W
-
-
COP
W/W
-
-
Sound Rating˄indoor˅ Sound Rating˄outdoor˅
bell+3
67
69
Air Circulation(Nominal)
Performance
bell+3
Type Tube Size(O.D) Evaporator
mm(inch)
Rows / Column / FPI Length Face Area
mm(inch) ༇(sq.ft)
Type * No. Used Indoor Fan
557(21 15/16) WEITELI
Belt/1
Belt/1
No. Motors
Capacity
Hp
Btu/h
Motor Type Motor Input
W
Oil Type Oil Charge
cc
Type Tube Size(O.D)
mm(inch)
Rows / Column / FPI Length Face Area
mm(inch) ༇(sq.ft)
Type * No. Used Diameter
inch
Maker Drive Type Air Circulation
3.0/5.0
1350/ 1360
1350/ 1360
1
1
SCROLL * 4
SCROLL * 2
JT160BATY1L DAKIN
JT335D-Y1L DAKIN
51200
116000
Three Phase
Three Phase
3750
9000
SUNISO 4GSD(I)-K
UP28UY081-400
2000
3000
High efficiency
High efficiency
9.52(3/8)
9.52(3/8)
3R / 40C / 14FPI*2
3R / 40C / 14FPI*2
-
-
0.50
0.50
Propeller * 2
Propeller * 2
-
-
-
-
Direct
Direct 8200
Hp
2EA / 1.5
2EA / 1.5
950
950
Liquid
mm(inch)
15.88(5/8)
15.88(5/8)
Gas
mm(inch)
28(9/8)
28(9/8)
Liquid
mm(inch)
15.88(5/8)
15.88(5/8)
Gas
mm(inch)
28(9/8)
28(9/8)
m(inch) ˜/h
7.5(295 9/32)
7.5(295 9/32)
Length(Standard) Dehumidification Rate Drain Connection Size(inch) Refrigerant Charge
Indoor Unit (W * H * D) Outdoor Unit (W * H * D)
17
17
1 1/4
1 1/4 8.8*2
kg
7.5*2
lbs
-
-
Type
R22
R22
Capillary Tube
Capillary Tube
mm
1800*890*1000
1800*890*1000
inch
70 7/8* 35 3/8 *39 3/8
70 7/8* 35 3/8 *39 3/8
mm
1560*1100*880
1760*1100*970
inch
69 1/4* 43 5/16 * 38 3/16 250˄550˅
Refrigerant Control
Fliter
1
3.0/5.0
8200
Motor RPM
Net Weight
1
CFM
No. Motor / Motor Output(Hp)
Dimensions
Centrifugal Blower
WEITELI
Maker
Refrigerant
1.14(12.33)
Centrifugal Blower
393(15 15/32)
Model
Connecting Pipe
1500(59 17/32)
1.14(12.33)
557(21 15/16)
Type * Quantity
Service Valve
1500(59 17/32)
393(15 15/32)
Motor RPM(Standard / Oversized)
Outdoor Motor
9.52(3/8) 3R / 30C / 17FPI
mm(inch)
No. of Outdoor Units
Outdoor Fan
9.52(3/8) 3R / 30C / 17FPI
mm(inch)
Motor Output(Standard / Oversized)
Condenser
75 High efficiency
Width Drive Type / Motor Step
Compressor
75 High efficiency
Diameter Maker
Indoor Motor
20 TN-C2408T00
3/380ѝ415/50
Power Supply M.C.A (with Standard Motor)
15 TN-C1808T00
Indoor Unit
kg(lbs)
61 7/16* 43 5/16 * 34 5/8 250˄550˅
Outdoor Unit or S/Package
kg(lbs)
280(616)
280(616)
-
-
-
-
Size * No. Used Filter Rack Thickness
inch
Note : 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27.0 (80.6°F ) DB/19.0 (66.2°F) WB - Outdoor Temperature 35 (95°F) DB/24 (75.2°F) WB Piping Length - Interconnecting Piping Length 7.5m '- Level Difference of Zero 2. Nominal CFM : Fan operation mode with clean filter, dry coil. 3. The specification may be subject to change without prior notice for purpose of improvement.
Ducted Split
Conversion Formula kcal/h = kW x 860 Btu/h = kW x 3412 cfm = m 3 /min x 35.3
3-9
TA5CUN2-01A
Dimensional Drawings
6. Dimensional Drawings Model No.: TN-C1808T00 1. Indoor units
18
890
00
00
10
1100
2. Oudoor units
156
0
0
88
Note: All dimensions are in mm
3-10
Ducted Split
TA5CUN2-01A
Dimensional Drawings
Model No.: TN-C2408T00 1. Indoor units
18
890
00
00
10
1100
2. Oudoor units
176
0
0
97
Note: All dimensions are in mm
Ducted Split
3-11
Type of Applications
3-12
TA5CUN2-01A
Ducted Split
TA5CUN2-01A
Wiring Diagrams
Model No.:TN-C1808T00 INDOOR UNIT WIRING DIAGRAM
TO OUTDOOR UNIT
OUTDOOR UNIT WIRING DIAGRAM
TO INDOOR UNIT
Ducted Split
3-13
TA5CUN2-01A
Wiring Diagrams
Model No.:TN-C2408T00
INDOOR UNIT WIRING DIGRAM
TO OUTDOOR UNIT
OUTDOOR UNIT WIRING DIGRAM
TO INDOOR UNIT
3-14
Ducted Split
Performance Data
TA5CUN2-01A
. . Performance data 9 table-1 Model No.:TN-C1808T00 Outdoor DB(ఁ) Indoor WB(ఁ) l/s
2001
2251
2501
2751
3001
29.4 16.1
DB(ఁ) TGC SHC
2001
2251
2501
2751
3001
PI
TGC SHC
22.8 PI
TGC SHC
16.1 PI
TGC SHC
40.6 22.8
19.4 PI
TGC SHC
PI
TGC SHC
16.1 PI
TGC SHC
19.4 PI
TGC SHC
22.8 PI
TGC SHC
PI
23.9
45.9
36.3 16.11 50.7
27.5 16.62 54.5
12.1 16.93 44.3
36.9 17.77 48.9
28.0 18.34 52.6
12.4 18.68 42.7
36.0 19.12 47.2
27.3 19.72 50.8
12.0 20.09
26.7
47.9
41.6 16.16 51.6
34.4 16.67 54.6
22.5 16.98 46.2
42.4 17.83 49.8
35.0 18.39 52.6
22.9 18.73 44.6
41.3 19.18 48.1
34.1 19.78 50.8
22.4 20.15
29.4
49.7
45.6 16.21 52.4
41.4 16.72 54.4
31.1 17.03 47.9
46.5 17.88 50.5
42.2 18.45 52.5
31.7 18.79 46.3
45.3 19.23 48.8
41.1 19.84 50.7
30.9 20.21
32.2
51.3
48.0 16.26 53.0
46.0 16.77 54.1
37.9 17.08 49.5
49.0 17.94 51.1
46.9 18.50 52.2
38.7 18.84 47.8
47.7 19.29 49.3
45.7 19.90 50.4
37.7 20.27
23.9
48.0
38.7 16.25 53.1
29.3 16.77 57.1
12.9 17.08 46.3
39.4 17.91 51.2
29.9 18.48 55.1
13.2 18.82 44.7
38.4 19.26 49.4
29.1 19.87 53.1
12.8 20.24
26.7
50.1
44.4 16.30 54.0
36.7 16.82 57.1
24.0 17.13 48.3
45.3 17.97 52.1
37.4 18.54 55.1
24.5 18.88 46.6
44.1 19.32 50.3
36.4 19.93 53.2
23.9 20.30
29.4
52.0
48.7 16.35 54.8
44.2 16.87 56.9
33.2 17.18 50.2
49.6 18.02 52.9
45.0 18.59 54.9
33.9 18.94 48.4
48.3 19.37 51.0
43.9 19.99 53.0
33.0 20.36
32.2
53.7
51.3 16.40 55.4
49.1 16.92 56.6
40.5 17.23 51.8
51.8 18.08 53.5
50.0 18.65 54.6
41.2 18.99 50.0
50.0 19.43 51.6
48.7 20.05 52.7
40.2 20.42
23.9
49.3
41.5 16.39 54.5
31.5 16.91 58.6
13.9 17.22 47.6
42.3 18.12 52.6
32.1 18.69 56.5
14.1 19.04 45.9
41.3 19.40 50.7
31.2 20.01 54.6
13.8 20.38
26.7
51.4
47.7 16.44 55.5
39.4 16.96 58.6
25.8 17.28 49.6
48.6 18.18 53.5
40.1 18.75 56.6
26.3 19.10 47.9
47.4 19.46 51.7
39.1 20.07 54.6
25.6 20.44
29.4
53.4
52.3 16.49 56.3
47.4 17.01 58.5
35.7 17.33 51.5
51.5 18.23 54.3
48.3 18.81 56.4
36.4 19.16 49.7
49.7 19.51 52.4
47.1 20.13 54.4
35.4 20.50
32.2
55.1
55.0 16.54 56.9
52.7 17.06 58.1
43.5 17.38 53.2
53.2 18.29 54.9
53.7 18.86 56.1
44.3 19.21 51.3
51.3 19.57 53.0
52.3 20.19 54.1
43.2 20.57
23.9
50.1
43.5 16.53 55.4
32.9 17.05 59.6
14.5 17.37 48.4
44.3 18.19 53.5
33.6 18.77 57.5
14.8 19.12 46.7
43.2 19.54 51.6
32.7 20.15 55.5
14.4 20.53
26.7
52.3
49.9 16.58 56.4
41.2 17.11 59.6
27.0 17.42 50.5
50.5 18.25 54.4
42.0 18.82 57.5
27.5 19.17 48.7
48.7 19.60 52.5
41.0 20.21 55.5
26.8 20.59
29.4
54.3
54.3 16.63 57.2
49.7 17.16 59.5
37.4 17.47 52.4
52.4 18.30 55.2
50.6 18.88 57.4
38.1 19.23 50.5
50.5 19.66 53.3
49.3 20.28 55.4
37.1 20.65
32.2
56.1
56.1 16.68 57.9
55.2 17.21 59.1
45.5 17.53 54.1
54.1 18.36 55.8
55.8 18.94 57.0
46.4 19.29 52.2
52.2 19.71 53.9
53.9 20.34 55.0
45.2 20.71
23.9
50.8
44.9 16.67 56.1
34.0 17.20 60.4
15.0 17.52 49.0
45.7 18.33 54.2
34.6 18.91 58.2
15.3 19.26 47.3
44.6 19.68 52.3
33.7 20.30 56.2
14.9 20.67
26.7
53.0
51.5 16.72 57.2
42.5 17.25 60.4
27.9 17.57 51.1
51.1 18.39 55.1
43.4 18.97 58.3
28.4 19.32 49.3
49.3 19.74 53.2
42.2 20.36 56.2
27.7 20.74
29.4
55.0
55.0 16.77 58.0
51.2 17.30 60.2
38.5 17.62 53.0
53.0 18.44 55.9
52.2 19.02 58.1
39.3 19.38 51.2
51.2 19.80 54.0
50.9 20.42 56.1
38.3 20.80
32.2
56.8
56.8 16.82 58.6
56.9 17.35 59.9
46.9 17.67 54.8
54.8 18.50 56.5
56.5 19.08 57.7
47.8 19.44 52.9
52.9 19.85 54.6
54.6 20.48 55.7
46.6 20.86
Outdoor DB(ఁ) Indoor WB(ఁ) l/s
35.0
19.4
51.7
46.1 16.1
DB(ఁ) TGC
19.4
22.8
16.1
19.4
22.8
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
23.9
40.3
35.0
20.23
44.6
26.5
20.87
47.9
11.7
21.26
37.3
33.4
21.16
41.3
25.3
21.83
44.4
11.2
22.24
26.7
42.1
40.2
20.29
45.4
33.2
20.93
47.9
21.8
21.32
39.0
38.4
21.23
42.0
31.7
21.90
44.4
20.8
22.30
29.4
43.7
43.7
20.35
46.0
40.0
20.99
47.8
30.1
21.38
40.4
40.4
21.29
42.6
38.2
21.96
44.3
28.7
22.37
32.2
45.1
45.1
20.41
46.5
44.5
21.06
47.5
36.7
21.45
41.8
41.8
21.35
43.1
42.4
22.03
44.0
35.0
22.44
23.9
42.2
37.4
20.37
46.6
28.3
21.01
50.2
12.5
21.40
39.1
35.7
21.30
43.2
27.0
21.97
46.5
11.9
22.38
26.7
44.0
42.9
20.43
47.5
35.5
21.08
50.2
23.2
21.47
40.8
40.8
21.37
44.0
33.8
22.04
46.5
22.2
22.45
29.4
45.7
45.7
20.49
48.2
42.7
21.14
50.0
32.1
21.53
42.3
42.3
21.43
44.6
40.8
22.11
46.3
30.7
22.52
32.2
47.2
47.2
20.55
48.7
47.4
21.20
49.7
39.1
21.60
43.7
43.7
21.49
45.1
45.1
22.17
46.1
37.3
22.58
23.9
43.3
40.1
20.51
47.9
30.4
21.16
51.5
13.4
21.55
40.1
38.3
21.44
44.4
29.0
22.12
47.7
12.8
22.53
26.7
45.2
45.2
20.57
48.7
38.1
21.22
51.5
24.9
21.61
41.9
41.9
21.51
45.2
36.3
22.18
47.7
23.8
22.60
29.4
46.9
46.9
20.63
49.5
45.9
21.28
51.4
34.5
21.68
43.4
43.4
21.57
45.8
43.8
22.25
47.6
32.9
22.66
32.2
48.4
48.4
20.69
50.0
50.0
21.35
51.0
42.0
21.74
44.9
44.9
21.64
46.3
46.3
22.32
47.3
40.1
22.73
23.9
44.1
42.0
20.65
48.7
31.8
21.30
52.4
14.0
21.69
40.8
40.1
21.58
45.1
30.4
22.26
48.5
13.4
22.68
26.7
46.0
46.0
20.71
49.6
39.9
21.36
52.4
26.1
21.76
42.6
42.6
21.65
45.9
38.0
22.33
48.5
24.9
22.74
29.4
47.7
47.7
20.77
50.3
48.0
21.43
52.2
36.1
21.83
44.2
44.2
21.71
46.6
45.8
22.40
48.4
34.5
22.81
32.2
49.3
49.3
20.83
50.8
50.8
21.49
51.9
44.0
21.89
45.6
45.6
21.78
47.1
47.1
22.46
48.1
42.0
22.88
23.9
44.6
43.4
20.79
49.3
32.8
21.44
53.0
14.5
21.84
41.3
41.3
21.72
45.7
31.3
22.41
49.1
13.8
22.82
26.7
46.6
46.6
20.85
50.2
41.1
21.51
53.1
26.9
21.91
43.1
43.1
21.79
46.5
39.2
22.47
49.1
25.7
22.89
29.4
48.3
48.3
20.91
50.9
49.5
21.57
52.9
37.2
21.97
44.7
44.7
21.85
47.2
47.2
22.54
49.0
35.5
22.96
32.2
49.9
49.9
20.98
51.5
51.5
21.64
52.6
45.4
22.04
46.2
46.2
21.92
47.7
47.7
22.61
48.7
43.3
23.03
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°C), WB = Wet Bulb Temperature (°C) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
Ducted Split
3-15
Performance Data
TA5CUN2-01A
table-2 Model No.:TN-C2408T00 Outdoor DB(ఁ) Indoor WB(ఁ) l/s DB(ఁ) 23.9 26.7 2643 29.4 32.2 23.9 26.7 2973 29.4 32.2 23.9 26.7 3303 29.4 32.2 23.9 26.7 3634 29.4 32.2 23.9 26.7 3964 29.4 32.2
TGC 57.8 60.3 62.6 64.6 60.5 63.1 65.5 67.6 62.1 64.8 67.2 69.4 63.1 65.9 68.4 70.6 63.9 66.7 69.2 71.5
Outdoor DB(ఁ) Indoor WB(ఁ) l/s DB(ఁ) 23.9 26.7 2643 29.4 32.2 23.9 26.7 2973 29.4 32.2 23.9 26.7 3303 29.4 32.2 23.9 26.7 3634 29.4 32.2 23.9 26.7 3964 29.4 32.2
16.1 SHC 45.6 52.4 57.4 60.5 48.7 55.9 61.3 64.5 52.3 60.1 65.8 69.3 54.8 62.9 68.4 70.6 56.5 64.9 69.2 71.5
TGC 50.8 53.0 55.0 56.8 53.1 55.4 57.5 59.4 54.5 56.9 59.0 61.0 55.5 57.9 60.1 62.0 56.2 58.6 60.8 62.8
PI 16.29 16.33 16.38 16.43 16.43 16.48 16.53 16.58 16.57 16.62 16.67 16.72 16.71 16.76 16.81 16.86 16.85 16.90 16.95 17.00
16.1 SHC 44.1 50.7 55.0 56.8 47.1 54.1 57.5 59.4 50.5 56.9 59.0 61.0 52.9 57.9 60.1 62.0 54.6 58.6 60.8 62.8
TGC 63.9 65.0 66.0 66.7 66.8 68.0 69.0 69.8 68.6 69.9 70.9 71.6 69.8 71.0 72.1 72.8 70.7 72.0 73.0 73.8
29.4 19.4 SHC 34.6 43.3 52.1 57.9 36.9 46.2 55.6 61.8 39.6 49.6 59.7 66.4 41.5 51.9 62.5 69.5 42.8 53.6 64.5 71.7
PI 20.45 20.51 20.57 20.63 20.59 20.65 20.71 20.77 20.73 20.79 20.85 20.91 20.87 20.93 20.99 21.06 21.01 21.07 21.14 21.20
PI 16.80 16.85 16.90 16.95 16.95 17.00 17.05 17.10 17.09 17.14 17.19 17.24 17.24 17.29 17.34 17.39 17.38 17.43 17.49 17.54
TGC 56.1 57.1 58.0 58.6 58.7 59.8 60.7 61.3 60.3 61.4 62.3 62.9 61.3 62.4 63.3 64.0 62.1 63.2 64.1 64.8
TGC 68.7 68.7 68.5 68.1 71.9 71.9 71.7 71.3 73.8 73.8 73.6 73.2 75.0 75.1 74.9 74.4 76.0 76.0 75.8 75.4
22.8 SHC 15.3 28.4 39.2 47.8 16.3 30.2 41.8 50.9 17.5 32.5 44.9 54.7 18.3 34.0 47.0 57.3 18.9 35.1 48.5 59.1
46.1 19.4 SHC 33.4 41.8 50.4 56.0 35.6 44.6 53.8 59.7 38.3 47.9 57.7 62.9 40.1 50.2 60.4 64.0 41.3 51.8 62.3 64.8
PI 17.11 17.16 17.21 17.27 17.26 17.31 17.36 17.42 17.41 17.46 17.51 17.56 17.56 17.61 17.66 17.71 17.70 17.76 17.81 17.86
PI 21.09 21.15 21.22 21.28 21.24 21.30 21.36 21.43 21.38 21.45 21.51 21.57 21.53 21.59 21.66 21.72 21.67 21.74 21.80 21.87
TGC 55.7 58.2 60.3 62.3 58.3 60.9 63.2 65.2 59.9 62.5 64.8 67.0 60.9 63.5 65.9 68.1 61.7 64.4 66.8 69.0
16.1 SHC 46.5 53.4 58.5 61.7 49.6 57.0 62.5 65.2 53.3 61.2 64.8 67.0 55.8 63.5 65.9 68.1 57.6 64.4 66.8 69.0
TGC 60.3 60.4 60.2 59.8 63.1 63.2 63.0 62.6 64.8 64.8 64.7 64.3 65.9 66.0 65.8 65.4 66.8 66.8 66.6 66.2
PI 17.96 18.02 18.07 18.13 18.11 18.16 18.21 18.27 18.32 18.37 18.43 18.48 18.39 18.44 18.50 18.55 18.53 18.58 18.64 18.70
22.8 SHC 14.7 27.4 37.9 46.2 15.7 29.2 40.4 49.2 16.9 31.4 43.4 52.9 17.7 32.9 45.5 55.4 18.2 33.9 46.9 57.1
TGC 61.6 62.7 63.6 64.3 64.5 65.6 66.6 67.3 66.2 67.4 68.4 69.1 67.3 68.5 69.5 70.3 68.2 69.4 70.4 71.2
35.0 19.4 SHC 35.2 44.1 53.1 59.0 37.6 47.1 56.7 63.0 40.4 50.5 60.9 67.6 42.3 52.9 63.7 70.3 43.6 54.6 65.7 71.2
PI 21.48 21.55 21.61 21.68 21.63 21.70 21.76 21.83 21.78 21.84 21.91 21.97 21.93 21.99 22.06 22.12 22.07 22.14 22.21 22.27
PI 18.53 18.59 18.64 18.70 18.68 18.73 18.79 18.85 18.89 18.95 19.01 19.06 18.97 19.02 19.08 19.14 19.11 19.17 19.23 19.28
TGC 47.0 49.1 50.9 52.6 49.2 51.3 53.3 55.0 50.5 52.7 54.7 56.5 51.4 53.6 55.6 57.4 52.0 54.3 56.3 58.2
TGC 66.3 66.3 66.1 65.7 69.3 69.4 69.2 68.7 71.2 71.2 71.0 70.6 72.4 72.4 72.2 71.8 73.3 73.4 73.1 72.7
22.8 SHC 15.5 28.9 40.0 48.7 16.6 30.8 42.6 51.9 17.8 33.1 45.8 55.8 18.7 34.7 47.9 58.4 19.2 35.7 49.4 60.2
16.1 SHC 42.1 48.4 50.9 52.6 44.9 51.3 53.3 55.0 48.2 52.7 54.7 56.5 50.5 53.6 55.6 57.4 52.0 54.3 56.3 58.2
PI 18.88 18.93 18.99 19.05 19.02 19.08 19.14 19.19 19.24 19.30 19.36 19.42 19.32 19.38 19.44 19.49 19.47 19.53 19.58 19.64
PI 21.39 21.45 21.52 21.58 21.53 21.59 21.66 21.72 21.67 21.74 21.80 21.87 21.81 21.88 21.94 22.01 21.95 22.02 22.08 22.15
TGC 53.8 56.1 58.2 60.2 56.3 58.7 60.9 62.9 57.8 60.3 62.6 64.6 58.8 61.3 63.6 65.7 59.5 62.1 64.5 66.6
16.1 SHC 45.3 52.1 57.1 60.1 48.4 55.5 60.9 62.9 51.9 59.6 62.6 64.6 54.4 61.3 63.6 65.7 56.1 62.1 64.5 66.6
TGC 52.0 52.9 53.7 54.3 54.4 55.4 56.2 56.8 55.8 56.8 57.7 58.3 56.8 57.8 58.7 59.3 57.5 58.6 59.4 60.0
PI 19.32 19.38 19.44 19.50 19.46 19.52 19.58 19.64 19.61 19.66 19.72 19.78 19.75 19.81 19.86 19.92 19.89 19.95 20.01 20.07
51.7 19.4 SHC 31.9 39.9 48.1 53.4 34.0 42.6 51.3 56.8 36.5 45.7 55.1 58.3 38.2 47.9 57.7 59.3 39.5 49.4 59.4 60.0
TGC 59.5 60.5 61.4 62.1 62.2 63.4 64.3 65.0 63.9 65.0 66.0 66.7 65.0 66.1 67.1 67.8 65.8 67.0 68.0 68.7
40.6 19.4 SHC 34.3 43.0 51.8 57.5 36.6 45.9 55.2 61.4 39.3 49.3 59.3 65.9 41.2 51.6 62.1 67.8 42.5 53.2 64.1 68.7
PI 22.06 22.13 22.20 22.26 22.21 22.28 22.34 22.41 22.35 22.42 22.49 22.56 22.50 22.57 22.63 22.70 22.64 22.71 22.78 22.85
PI 19.93 19.99 20.05 20.11 20.08 20.14 20.20 20.26 20.22 20.28 20.35 20.41 20.37 20.43 20.49 20.55 20.51 20.58 20.64 20.70
TGC 55.9 55.9 55.8 55.4 58.5 58.5 58.3 58.0 60.0 60.1 59.9 59.5 61.1 61.1 60.9 60.6 61.8 61.9 61.7 61.3
TGC 63.9 64.0 63.8 63.4 66.9 66.9 66.8 66.3 68.7 68.7 68.5 68.1 69.9 69.9 69.7 69.3 70.8 70.8 70.6 70.2
22.8 SHC 15.2 28.2 38.9 47.4 16.2 30.0 41.6 50.6 17.4 32.3 44.6 54.3 18.2 33.8 46.7 56.9 18.7 34.8 48.2 58.7
22.8 SHC 14.1 26.2 36.2 44.0 15.0 27.9 38.6 47.0 16.1 30.0 41.4 50.5 16.9 31.4 43.4 52.8 17.4 32.4 44.8 54.5
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°C), WB = Wet Bulb Temperature (°C) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
3-16
Ducted Split
PI 20.30 20.36 20.43 20.49 20.45 20.51 20.57 20.64 20.60 20.66 20.72 20.78 20.75 20.81 20.87 20.93 20.89 20.96 21.02 21.08
PI 22.47 22.54 22.61 22.68 22.62 22.69 22.76 22.83 22.77 22.84 22.91 22.97 22.92 22.99 23.06 23.12 23.07 23.13 23.20 23.27
Performance Data
TA5CUN2-01A
Cooling Capacity(English Units) table-3 Model No.:TN-C1808T00 Outdoor DB(ሥ) Indoor WB(ሥ) CFM
4240
4770
5300
5830
6360
85 61
DB(ሥ) TGC SHC
4240
4770
5300
5830
6360
PI
TGC SHC
73 PI
TGC SHC
61 PI
TGC SHC
105
67 PI
TGC SHC
73 PI
TGC SHC
61 PI
TGC SHC
67 PI
TGC SHC
73 PI
TGC SHC
PI
75
156.6 123.7 16.11 173.2 93.7 16.62 186.2 41.4 16.93 151.1 126.1 17.77 167.0 95.5 18.34 179.6 42.2 18.68 145.8 122.9 19.12 161.2 93.1 19.72 173.3 41.1 20.09
80
163.4 142.1 16.16 176.3 117.3 16.67 186.2 76.9 16.98 157.6 144.8 17.83 170.0 119.6 18.39 179.7 78.3 18.73 152.1 141.1 19.18 164.1 116.5 19.78 173.4 76.3 20.15
85
169.6 155.7 16.21 178.8 141.3 16.72 185.7 106.3 17.03 163.6 158.7 17.88 172.5 144.0 18.45 179.2 108.3 18.79 157.9 154.7 19.23 166.5 140.4 19.84 172.9 105.6 20.21
90
175.1 164.0 16.26 180.7 157.0 16.77 184.6 129.4 17.08 169.0 167.1 17.94 174.4 160.0 18.50 178.1 131.9 18.84 163.1 162.9 19.29 168.3 155.9 19.90 171.9 128.6 20.27
75
163.9 132.0 16.25 181.2 100.0 16.77 194.8 44.1 17.08 158.1 134.5 17.91 174.8 101.9 18.48 187.9 45.0 18.82 152.6 131.1 19.26 168.7 99.3 19.87 181.4 43.8 20.24
80
171.0 151.6 16.30 184.5 125.2 16.82 194.9 82.0 17.13 165.0 154.5 17.97 178.0 127.6 18.54 188.0 83.6 18.88 159.2 150.6 19.32 171.7 124.3 19.93 181.5 81.4 20.30
85
177.5 166.2 16.35 187.1 150.8 16.87 194.4 113.4 17.18 171.2 169.3 18.02 180.5 153.7 18.59 187.5 115.6 18.94 165.2 165.0 19.37 174.2 149.8 19.99 181.0 112.6 20.36
90
183.3 175.0 16.40 189.1 167.5 16.92 193.2 138.1 17.23 176.8 176.8 18.08 182.5 170.7 18.65 186.4 140.7 18.99 170.6 170.6 19.43 176.1 166.4 20.05 179.8 137.2 20.42
75
168.3 141.8 16.39 186.0 107.4 16.91 200.0 47.4 17.22 162.3 144.5 18.12 179.5 109.4 18.69 192.9 48.3 19.04 156.6 140.8 19.40 173.2 106.6 20.01 186.2 47.1 20.38
80
175.5 162.8 16.44 189.4 134.4 16.96 200.1 88.1 17.28 169.3 165.9 18.18 182.7 137.0 18.75 193.0 89.7 19.10 163.4 161.7 19.46 176.3 133.5 20.07 186.3 87.4 20.44
85
182.2 178.4 16.49 192.1 161.9 17.01 199.5 121.8 17.33 175.7 175.7 18.23 185.3 165.0 18.81 192.5 124.1 19.16 169.6 169.6 19.51 178.8 160.8 20.13 185.8 120.9 20.50
90
188.1 187.9 16.54 194.2 179.9 17.06 198.3 148.3 17.38 181.5 181.5 18.29 187.3 183.3 18.86 191.3 151.1 19.21 175.2 175.2 19.57 180.8 178.6 20.19 184.6 147.3 20.57
75
171.1 148.4 16.53 189.2 112.4 17.05 203.4 49.6 17.37 165.1 151.3 18.19 182.5 114.5 18.77 196.2 50.6 19.12 159.3 147.4 19.54 176.1 111.6 20.15 189.4 49.3 20.53
80
178.5 170.4 16.58 192.6 140.8 17.11 203.5 92.2 17.42 172.2 172.2 18.25 185.8 143.4 18.82 196.3 93.9 19.17 166.2 166.2 19.60 179.3 139.8 20.21 189.5 91.6 20.59
85
185.3 185.3 16.63 195.4 169.5 17.16 202.9 127.5 17.47 178.7 178.7 18.30 188.5 172.8 18.88 195.8 129.9 19.23 172.5 172.5 19.66 181.9 168.4 20.28 188.9 126.6 20.65
90
191.4 191.4 16.68 197.5 188.3 17.21 201.7 155.3 17.53 184.6 184.6 18.36 190.5 190.5 18.94 194.6 158.2 19.29 178.2 178.2 19.71 183.9 183.9 20.34 187.8 154.2 20.71
75
173.3 153.1 16.67 191.6 115.9 17.20 206.0 51.2 17.52 167.2 156.0 18.33 184.9 118.2 18.91 198.7 52.2 19.26 161.4 152.0 19.68 178.4 115.1 20.30 191.8 50.8 20.67
80
180.8 175.8 16.72 195.1 145.2 17.25 206.1 95.1 17.57 174.5 174.5 18.39 188.2 148.0 18.97 198.8 96.9 19.32 168.4 168.4 19.74 181.6 144.2 20.36 191.9 94.4 20.74
85
187.7 187.7 16.77 197.9 174.9 17.30 205.5 131.5 17.62 181.0 181.0 18.44 190.9 178.2 19.02 198.3 134.0 19.38 174.7 174.7 19.80 184.2 173.7 20.42 191.4 130.6 20.80
90
193.8 193.8 16.82 200.0 194.3 17.35 204.3 160.2 17.67 187.0 187.0 18.50 193.0 193.0 19.08 197.1 163.2 19.44 180.5 180.5 19.85 186.2 186.2 20.48 190.2 159.1 20.86
Outdoor DB(ሥ) Indoor WB(ሥ) CFM
95
67
115 61
DB(ሥ) TGC
125
67
73
67
61
73
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
TGC
SHC
PI
40.0
21.26
127.5
114.1
21.16
140.9
86.4
21.83
151.5
38.2
22.24
75
137.6
119.6
20.23
152.1
90.6
20.87
163.6
80
143.6
137.3
20.29
154.9
113.4
20.93
163.6
74.3
21.32
133.0
131.1
21.23
143.4
108.2
21.90
151.6
70.9
22.30
85
149.0
149.0
20.35
157.1
136.6
20.99
163.2
102.7
21.38
138.0
138.0
21.29
145.5
130.4
21.96
151.1
98.0
22.37
90
153.9
153.9
20.41
158.8
151.8
21.06
162.2
125.1
21.45
142.5
142.5
21.35
147.1
144.8
22.03
150.2
119.4
22.44
75
144.0
127.6
20.37
159.2
96.6
21.01
171.2
42.7
21.40
133.4
121.8
21.30
147.5
92.2
21.97
158.5
40.7
22.38
80
150.2
146.5
20.43
162.1
121.0
21.08
171.2
79.3
21.47
139.2
139.2
21.37
150.1
115.5
22.04
158.6
75.6
22.45
85
155.9
155.9
20.49
164.4
145.7
21.14
170.8
109.6
21.53
144.4
144.4
21.43
152.3
139.1
22.11
158.2
104.6
22.52
90
161.0
161.0
20.55
166.2
161.9
21.20
169.7
133.5
21.60
149.2
149.2
21.49
153.9
153.9
22.17
157.2
127.4
22.58
75
147.8
137.0
20.51
163.4
103.8
21.16
175.7
45.8
21.55
136.9
130.8
21.44
151.4
99.0
22.12
162.7
43.7
22.53
80
154.2
154.2
20.57
166.4
129.9
21.22
175.8
85.1
21.61
142.9
142.9
21.51
154.1
124.0
22.18
162.8
81.2
22.60
85
160.1
160.1
20.63
168.8
156.5
21.28
175.3
117.7
21.68
148.2
148.2
21.57
156.3
149.3
22.25
162.4
112.3
22.66
90
165.3
165.3
20.69
170.6
170.6
21.35
174.2
143.3
21.74
153.1
153.1
21.64
158.0
158.0
22.32
161.4
136.8
22.73
75
150.4
143.5
20.65
166.2
108.6
21.30
178.7
48.0
21.69
139.3
136.9
21.58
154.0
103.7
22.26
165.5
45.8
22.68
80
156.9
156.9
20.71
169.2
136.0
21.36
178.8
89.1
21.76
145.3
145.3
21.65
156.7
129.8
22.33
165.6
85.0
22.74
85
162.8
162.8
20.77
171.7
163.8
21.43
178.3
123.2
21.83
150.8
150.8
21.71
159.0
156.4
22.40
165.1
117.6
22.81
90
168.1
168.1
20.83
173.5
173.5
21.49
177.2
150.1
21.89
155.7
155.7
21.78
160.7
160.7
22.46
164.1
143.2
22.88
75
152.3
148.0
20.79
168.4
112.1
21.44
181.0
49.5
21.84
141.1
141.1
21.72
155.9
106.9
22.41
167.7
47.2
22.82
80
158.9
158.9
20.85
171.4
140.3
21.51
181.1
91.9
21.91
147.2
147.2
21.79
158.8
133.9
22.47
167.7
87.7
22.89
85
164.9
164.9
20.91
173.9
169.0
21.57
180.6
127.1
21.97
152.7
152.7
21.85
161.0
161.0
22.54
167.3
121.3
22.96
90
170.3
170.3
20.98
175.7
175.7
21.64
179.5
154.8
22.04
157.7
157.7
21.92
162.8
162.8
22.61
166.2
147.7
23.03
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
Ducted Split
3-17
Performance Data
TA5CUN2-01A
Cooling Capacity(English Units) table-4 Model No.:TN-C2408T00 Outdoor DB(ሥ) Indoor WB(ሥ) CFM DB(ሥ) 75 80 5600 85 90 75 80 6300 85 90 75 80 7000 85 90 75 80 7700 85 90 75 80 8400 85 90
85 95 105 61 67 73 61 67 73 61 67 73 TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI TGC SHC PI 197.2 155.8 16.29 218.0 118.0 16.80 234.4 52.1 17.11 190.2 158.8 17.96 210.3 120.2 18.53 226.1 53.1 18.88 183.6 154.7 19.32 203.0 117.2 19.93 218.2 51.7 20.30 205.7 178.9 16.33 221.9 147.7 16.85 234.5 96.8 17.16 198.5 182.3 18.02 214.1 150.6 18.59 226.2 98.6 18.93 191.5 177.7 19.38 206.6 146.7 19.99 218.3 96.1 20.36 213.5 196.1 16.38 225.1 177.9 16.90 233.8 133.8 17.21 206.0 199.8 18.07 217.2 181.3 18.64 225.6 136.4 18.99 198.8 194.7 19.44 209.6 176.7 20.05 217.7 132.9 20.43 220.5 206.5 16.43 227.5 197.7 16.95 232.4 163.0 17.27 212.7 210.4 18.13 219.5 201.5 18.70 224.2 166.1 19.05 205.3 205.1 19.50 211.8 196.3 20.11 216.4 161.9 20.49 206.4 166.2 16.43 228.2 125.9 16.95 245.3 55.6 17.26 199.1 169.4 18.11 220.1 128.3 18.68 236.6 56.6 19.02 192.1 165.1 19.46 212.4 125.0 20.08 228.4 55.2 20.45 215.3 190.9 16.48 232.2 157.6 17.00 245.4 103.2 17.31 207.7 194.5 18.16 224.1 160.6 18.73 236.7 105.2 19.08 200.4 189.6 19.52 216.2 156.6 20.14 228.5 102.5 20.51 223.4 209.2 16.53 235.6 189.8 17.05 244.7 142.8 17.36 215.5 213.2 18.21 227.3 193.5 18.79 236.1 145.5 19.14 208.0 207.8 19.58 219.4 188.5 20.20 227.8 141.8 20.57 230.8 220.3 16.58 238.1 210.9 17.10 243.2 173.9 17.42 222.6 222.6 18.27 229.7 214.9 18.85 234.6 177.2 19.19 214.8 214.8 19.64 221.7 209.5 20.26 226.4 172.7 20.64 211.8 178.5 16.57 234.2 135.2 17.09 251.8 59.7 17.41 204.4 181.9 18.32 225.9 137.7 18.89 242.9 60.8 19.24 197.2 177.3 19.61 218.1 134.2 20.22 234.4 59.3 20.60 221.0 205.0 16.62 238.4 169.3 17.14 251.9 110.9 17.46 213.2 208.9 18.37 230.0 172.5 18.95 243.0 113.0 19.30 205.8 203.6 19.66 222.0 168.1 20.28 234.5 110.1 20.66 229.4 224.6 16.67 241.9 203.9 17.19 251.2 153.3 17.51 221.3 221.3 18.43 233.3 207.7 19.01 242.3 156.3 19.36 213.5 213.5 19.72 225.2 202.5 20.35 233.9 152.3 20.72 236.9 236.6 16.72 244.5 226.5 17.24 249.7 186.7 17.56 228.5 228.5 18.48 235.8 230.8 19.06 240.9 190.3 19.42 220.5 220.5 19.78 227.6 224.9 20.41 232.4 185.4 20.78 215.5 186.9 16.71 238.2 141.5 17.24 256.1 62.5 17.56 207.9 190.4 18.39 229.8 144.2 18.97 247.1 63.7 19.32 200.6 185.6 19.75 221.8 140.5 20.37 238.4 62.0 20.75 224.8 214.6 16.76 242.5 177.2 17.29 256.2 116.1 17.61 216.9 216.9 18.44 233.9 180.6 19.02 247.2 118.3 19.38 209.3 209.3 19.81 225.8 176.0 20.43 238.5 115.3 20.81 233.3 233.3 16.81 246.0 213.4 17.34 255.5 160.5 17.66 225.0 225.0 18.50 237.3 217.5 19.08 246.5 163.6 19.44 217.2 217.2 19.86 229.0 212.0 20.49 237.9 159.4 20.87 240.9 240.9 16.86 248.6 237.1 17.39 253.9 195.5 17.71 232.4 232.4 18.55 239.9 239.9 19.14 245.0 199.2 19.49 224.3 224.3 19.92 231.5 231.5 20.55 236.4 194.1 20.93 218.2 192.8 16.85 241.3 146.0 17.38 259.4 64.4 17.70 210.5 196.4 18.53 232.8 148.8 19.11 250.2 65.7 19.47 203.2 191.4 19.89 224.6 145.0 20.51 241.5 64.0 20.89 227.7 221.4 16.90 245.6 182.8 17.43 259.5 119.7 17.76 219.6 219.6 18.58 236.9 186.3 19.17 250.3 122.0 19.53 212.0 212.0 19.95 228.7 181.5 20.58 241.6 118.9 20.96 236.3 236.3 16.95 249.2 220.2 17.49 258.8 165.6 17.81 227.9 227.9 18.64 240.4 224.4 19.23 249.6 168.8 19.58 220.0 220.0 20.01 232.0 218.6 20.64 240.9 164.5 21.02 244.0 244.0 17.00 251.8 244.6 17.54 257.2 201.6 17.86 235.4 235.4 18.70 242.9 242.9 19.28 248.1 205.5 19.64 227.2 227.2 20.07 234.5 234.5 20.70 239.5 200.3 21.08
Outdoor DB( ሥ) Indoor WB(ሥ) CFM DB(ሥ) 75 80 5600 85 90 75 80 6300 85 90 75 80 7000 85 90 75 80 7700 85 90 75 80 8400 85 90
TGC 173.3 180.8 187.6 193.7 181.3 189.2 196.3 202.7 186.1 194.2 201.5 208.1 189.3 197.5 205.0 211.7 191.7 200.0 207.6 214.4
61 SHC 150.6 172.9 187.6 193.7 160.7 184.5 196.3 202.7 172.5 194.2 201.5 208.1 180.6 197.5 205.0 211.7 186.3 200.0 207.6 214.4
PI 20.45 20.51 20.57 20.63 20.59 20.65 20.71 20.77 20.73 20.79 20.85 20.91 20.87 20.93 20.99 21.06 21.01 21.07 21.14 21.20
TGC 191.5 195.0 197.8 199.9 200.5 204.1 207.0 209.2 205.8 209.5 212.5 214.8 209.3 213.1 216.1 218.4 212.0 215.8 218.9 221.3
115 67 SHC 114.0 142.8 172.0 191.1 121.7 152.4 183.5 203.9 130.6 163.6 197.0 214.8 136.8 171.3 206.3 218.4 141.1 176.7 212.8 221.3
PI 21.09 21.15 21.22 21.28 21.24 21.30 21.36 21.43 21.38 21.45 21.51 21.57 21.53 21.59 21.66 21.72 21.67 21.74 21.80 21.87
TGC 205.9 206.0 205.4 204.2 215.5 215.6 215.0 213.7 221.2 221.3 220.7 219.4 225.0 225.1 224.5 223.1 227.9 228.0 227.4 226.0
73 SHC 50.3 93.5 129.4 157.5 53.7 99.8 138.0 168.1 57.7 107.1 148.2 180.5 60.4 112.2 155.2 188.9 62.3 115.7 160.0 194.9
PI 21.48 21.55 21.61 21.68 21.63 21.70 21.76 21.83 21.78 21.84 21.91 21.97 21.93 21.99 22.06 22.12 22.07 22.14 22.21 22.27
TGC 160.5 167.4 173.7 179.4 167.9 175.2 181.8 187.8 172.4 179.9 186.7 192.8 175.3 182.9 189.8 196.1 177.6 185.3 192.3 198.6
61 SHC 143.7 165.0 173.7 179.4 153.3 175.2 181.8 187.8 164.6 179.9 186.7 192.8 172.4 182.9 189.8 196.1 177.6 185.3 192.3 198.6
PI 21.39 21.45 21.52 21.58 21.53 21.59 21.66 21.72 21.67 21.74 21.80 21.87 21.81 21.88 21.94 22.01 21.95 22.02 22.08 22.15
TGC 177.4 180.6 183.2 185.2 185.7 189.0 191.7 193.8 190.6 194.0 196.8 198.9 193.9 197.3 200.2 202.3 196.3 199.9 202.8 204.9
125 67 SHC 108.8 136.3 164.1 182.3 116.1 145.4 175.1 193.8 124.7 156.1 188.0 198.9 130.5 163.5 196.9 202.3 134.6 168.6 202.8 204.9
PI 22.06 22.13 22.20 22.26 22.21 22.28 22.34 22.41 22.35 22.42 22.49 22.56 22.50 22.57 22.63 22.70 22.64 22.71 22.78 22.85
TGC 190.7 190.8 190.3 189.1 199.6 199.7 199.1 197.9 204.9 205.0 204.4 203.2 208.4 208.5 207.9 206.7 211.1 211.2 210.6 209.3
73 SHC 48.0 89.3 123.4 150.3 51.2 95.2 131.7 160.4 55.0 102.3 141.4 172.2 57.6 107.1 148.1 180.3 59.4 110.4 152.7 186.0
PI 22.47 22.54 22.61 22.68 22.62 22.69 22.76 22.83 22.77 22.84 22.91 22.97 22.92 22.99 23.06 23.12 23.07 23.13 23.20 23.27
Notes: 1. All capacities are gross, evaporator fan motor heat is not deducted. To obtain net cooling capacity, subtract evaporator fan motor heat. 2. DB = Dry Bulb Temperature (°F), WB = Wet Bulb Temperature (°F) 3. CFM = Cubic Feet per minute 4. TGC = Total Gross Cooling Capacity(Unit : MBH = 1000Btu/hr) 5. SHC = Sensible Heat Capacity(Unit : MBH = 1000Btu/hr) 6. PI = Power Input(kW), Sum of Compressor & Outdoor Fan Power Input
3-18
Ducted Split
Performance Data
TA5CUN2-01A
Evaporator Fan Performance TN-C1808T00 (English)
Table-5
External Static Pressure(in.Aq.) CFM
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 4240 596 1.05 606 1.12 617 1.21 630 1.32 646 1.44 663 1.57 681 1.72 701 1.87 722 2.04 745 2.21 768 2.40 792 2.59 4770 643 1.70 651 1.77 663 1.86 677 1.97 692 2.09 710 2.22 728 2.37 748 2.52 769 2.69 790 2.86 814 3.04 839 3.24 5300 692 2.39 701 2.46 712 2.55 726 2.65 741 2.77 758 2.91 776 3.05 796 3.21 817 3.37 840 3.55 864 3.73 888 3.92 5830 744 3.11 752 3.18 764 3.27 777 3.37 792 3.49 810 3.63 829 3.77 848 3.93 870 4.09 891 4.27 915 4.45 939 4.64 6360 797 3.86 807 3.93 818 4.02 831 4.13 847 4.25 864 4.38 882 4.53 902 4.68 923 4.85 946 5.00 3Hp STANDARD MOTOR & DRIVE
External Static Pressure(in.Aq.) CFM
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3Hp STANDARD MOTOR & HIGH STATIC DRIVE 5Hp OVER SIZED MOTOR & DRIVE
4240 818 2.79 845 3.00 872 3.21 901 3.44 930 3.67 961 3.90 991 4.15 1024 4.40 4770 865 3.44 891 3.65 919 3.86 948 4.08 976 4.32 1007 4.55 1038 4.80 1070 5.00 5300 913 4.12 940 4.33 968 4.55 996 4.77 1026 5.00 5830 965 4.84 991 5.00 6360
• Fan motor heat(MBH)= 3.1 x Fan BHP • Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Ducted Split
3-19
Performance Data
TA5CUN2-01A
Evaporator Fan Performance TN-C1808T00 (SI)
Table-6
External Static Pressure(mmAq.) l/s
2.5
5.1
7.6
10.2
12.7
15.2
17.8
20.3
22.9
25.4
27.9
30.5
RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW 2001 596 0.79 606 0.84 617 0.90 630 0.98 646 1.07 663 1.17 681 1.28 701 1.40 722 1.52 745 1.65 768 1.79 792 1.93 2251 643 1.27 651 1.32 663 1.39 677 1.47 692 1.56 710 1.66 728 1.76 748 1.88 769 2.00 790 2.13 814 2.27 839 2.41 2501 692 1.78 701 1.83 712 1.90 726 1.98 741 2.07 758 2.17 776 2.28 796 2.39 817 2.51 840 2.64 864 2.78 888 2.93 2751 744 2.32 752 2.37 764 2.44 777 2.52 792 2.61 810 2.71 829 2.81 848 2.93 870 3.05 891 3.18 915 3.32 939 3.46 3002 797 2.88 807 2.93 818 3.00 831 3.08 847 3.17 864 3.27 882 3.38 902 3.49 923 3.62 946 3.70 3Hp STANDARD MOTOR & DRIVE
External Static Pressure(mmAq.) l/s
33.0
35.6
38.1
40.6
43.2
45.7
48.3
3Hp STANDARD MOTOR & HIGH STATIC DRIVE
50.8
5Hp OVER SIZED MOTOR & DRIVE
RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW RPM BkW 2001 818 2.08 845 2.23 872 2.40 901 2.56 930 2.73 961 2.91 991 3.09 1024 3.28 2251 865 2.56 891 2.72 919 2.88 948 3.05 976 3.22 1007 3.39 1038 3.58 1070 3.70 2501 913 3.07 940 3.23 968 3.39 996 3.56 1026 3.70 2751 965 3.61 991 3.70 3002
• Fan motor heat(kW)= 1.22 x Fan BkW • Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Fan speed Data TN-C1808T00(RPM)
Table-7
0 TURN OPEN 1 TURN OPEN 2 TURN OPEN 3 TURN OPEN 4 TURN OPEN 5 TURN OPEN 6 TURN OPEN Standard Motor & Drive Fan Speed Standard Motor & High Static Drive Accessory Fan Speed Over Sized Motor & Drive Fan Speed
820
782
745
708
670
633
595
996
951
906
860
815
770
724
1199
1145
1090
1035
981
927
871
• Factory set at 3 turns open.
3-20
Ducted Split
Performance Data
TA5CUN2-01A
Evaporator Fan Performance TN-C2408T00 (English)
Table-8
CFM 4240 4770 5300 5830 6360
0.1 RPM 1069 1153 1241 1334 1429
BHP 1.883 3.048 4.285 5.576 6.921
0.2 RPM 1087 1167 1257 1348 1447
BHP 2.008 3.174 4.411 5.702 7.046
0.3 RPM 1106 1189 1277 1370 1467
BHP 2.17 3.335 4.572 5.863 7.208
0.4 RPM 1130 1214 1302 1393 1490
BHP 2.367 3.532 4.751 6.042 7.405
External Static Pressure(in.Aq.) 0.6 0.7
0.5 RPM 1158 1241 1329 1420 1519
BHP 2.582 3.747 4.967 6.258 7.62
RPM 1189 1273 1359 1452 1549
BHP 2.815 3.98 5.218 6.509 7.853
RPM 1221 1305 1391 1486 1581
BHP 3.084 4.249 5.469 6.76 8.122
0.8
RPM 1257 1341 1427 1520 1617
BHP 3.353 4.518 5.756 7.046 8.391
0.9 RPM 1295 1379 1465 1560 1655
1
BHP 3.658 4.823 6.042 7.333 8.696
RPM 1336 1416 1506 1598 1696
1.1 BHP 3.963 5.128 6.365 7.656 8.965
RPM 1377.024 1459.502 1549.152 1640.595
1.2 BHP 4.303 5.451 6.688 7.979
RPM 1420 1504 1592 1684
BHP 4.644 5.809 7.029 8.32
3Hp STANDARD MOTOR & DRIVE
CFM 4240 4770 5300 5830 6360
1.3 RPM 1467 1551 1637 1730
BHP 5.002 6.168 7.387 8.678
1.4 RPM 1515 1598 1685 1777
BHP 5.379 6.544 7.764 8.965
1.5 RPM 1563 1648 1736
BHP 5.756 6.921 8.158
External Static Pressure(in.Aq.) 1.6 1.7 RPM 1615 1700 1786
BHP 6.168 7.315 8.553
RPM 1667 1750 1840
3Hp STANDARD MOTOR & HIGH STATIC DRIVE
1.8
1.9
2
5Hp OVER SIZED MOTOR & DRIVE
BHP RPM BHP RPM BHP RPM BHP 6.58 1723 6.993 1777 7.441 1836 7.889 7.746 1806 8.158 1861 8.606 1919 8.965 8.965
• Fan motor heat(MBH)= 3.1 x Fan BHP • Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Ducted Split
3-21
Performance Data
TA5CUN2-01A
Evaporator Fan Performance TN-C2408T00 (SI)
Table-9
l/s 2001 2251 2501 2751 3002
l/s 2001 2251 2501 2751 3002
2.5 RPM 1069 1153 1241 1334 1429
BkW 1.416 2.277 3.192 4.16 5.164
33 RPM 1467 1551 1637 1730
5.1 RPM 1087 1167 1257 1348 1447
BkW 1.506 2.367 3.281 4.249 5.253
35.6 BkW 3.729 4.59 5.505 6.473
RPM 1515 1598 1685 1777
BkW 3.998 4.877 5.791 6.634
7.6 RPM 1106 1189 1277 1370 1467
BkW 1.614 2.492 3.407 4.375 5.379
38.1 RPM 1563 1648 1736
10.2 RPM 1130 1214 1302 1393 1490
External Static Pressure(mmAq.) 15.2 17.8 20.3
12.7
BkW 1.757 2.636 3.55 4.518 5.522
RPM 1158 1241 1329 1420 1519
BkW 1.919 2.797 3.712 4.68 5.684
External Static Pressure(mmAq.) 40.6 43.2
BkW 4.303 5.164 6.078
RPM 1615 1700 1786
BkW 4.59 5.469 6.383
RPM 1667 1750 1840
RPM 1189 1273 1359 1452 1549
BkW 2.098 2.976 3.891 4.859 5.863
RPM 1221 1305 1391 1486 1581
BkW 2.295 3.156 4.088 5.038 6.06
RPM 1257 1341 1427 1520 1617
BkW 2.51 3.371 4.285 5.253 6.258
22.9 RPM 1295 1379 1465 1560 1655
25.4
BkW 2.725 3.586 4.5 5.469 6.491
RPM 1336 1416 1506 1598 1696
BkW 2.958 3.819 4.734 5.702 6.634
27.9 RPM 1377.024 1459.502 1549.152 1640.595
30.5 BkW 3.209 4.07 4.985 5.953
RPM 1420 1504 1592 1684
3Hp STANDARD MOTOR & DRIVE
45.7
48.3
3Hp STANDARD MOTOR & HIGH STATIC DRIVE
50.8
5Hp OVER SIZED MOTOR & DRIVE
BkW RPM BkW RPM BkW RPM BkW 4.895 1723 5.218 1777 5.54 1836 5.881 5.773 1806 6.078 1861 6.419 1919 6.634 6.634
• Fan motor heat(kW)= 1.22 x Fan BkW • Test Condition: Voltage : 380V Operating Mode: Fan operation mode with clean filter, dry coil, without electric heater.
Fan speed Data TN-C2408T00(RPM)
Table-10
0 TURN OPEN 1 TURN OPEN 2 TURN OPEN 3 TURN OPEN 4 TURN OPEN 5 TURN OPEN 6 TURN OPEN Standard Motor & Drive Fan Speed
1470
1402
1336
1269
1201
1135
1067
Standard Motor & High Static Drive Accessory Fan Speed Over Sized Motor & Drive Fan Speed
1786
1705
1624
1542
1461
1381
1298
2150
2053
1954
1856
1759
1662
1562
• Factory set at 3 turns open.
3-22
BkW 3.46 4.321 5.253 6.204
Ducted Split
Electrical Data
TA5CUN2-01A
10. Electrical Data Electrical Data, Cooling
Tab le-11
Standard indoor fan motor *M.F.S.
RT
MODEL
Unit Operating Voltage Range
*M.C.A.
15
TN-C1808T00
342~456
3.5
10
20
20
TN-C2408T00
342~456
6.0
10
20
*M.C.B
Note: *M.C.A.: Minimum Circuit Ampacity *M.F.S.: Maximum Fuse Size *M.C.B.: Maximum Circuit Breaker
Table-7
Electrical Characteristics --- Evaporator Fan Motor --- 50 Hz
MODEL
Standard indoor fan motor Phase
No
Volts
TN-C1808T00
1
380-415
TN-C2408T00
1
380-415
Table-8 MODEL
FLA
3
3
5.2
3
3
6.2
Electrical Characteristics --- Compressor and Outdoor Fan Motor --- 50 Hz COMPRESSOR Phase HP
No
Volts
TN-C1808T00
4
380-415
3
TN-C2408T00
2
380-415
3
Note:
HP
OUTDOOR FAN MOTOR Volts Phase HP
FLA
LRA
No
5
8.6
65.8
2
380-415
3
1.5
2
12
17.0
2
380-415
3
1.5
2
129
FLA
FLA -Full Load Amps. LRA- Locked Rotor Amps.
Ducted Split
3-23
TA5CUN2-01A
Temperature,Pressure Chart
11. Temperature, Pressure Chart Model No. : TN-C1808T00 ( C) 22
9
21 20
8
19
7
17 16 15
6
14 13 12
5
11 10
4
9
Low Pressure(Kg/cm2)
Discharge Air Temp. DB(°C)
18
8 3
7 21 C
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53 (kg/cm2)
Outdoor Temp. DB(°C) : Discharge Air Temperature, °C : Low Pressure, Kg/cm2
Model No. : TN-C2408T00 ( C) 22
9
21 20
8
19
7
17 16 15
6
14 13 12
5
11 10
4
9
Low Pressure(Kg/cm2)
Discharge Air Temp. DB(°C)
18
8 3
7 21 C
23
25
27
29
31
33
35
37
39
41
Outdoor Temp. DB(°C) : Discharge Air Temperature, °C : Low Pressure, Kg/cm2
3-24
Ducted Split
43
45
47
49
51
53 (kg/cm2)
Refrigerant Cycle Diagrams
TA5CUN2-01A
12. Refrigerant Cycle Diagrams Model No.: TN-C1808T00 INDOOR COIL
OUTDOOR COIL HI-PRESSURE COMPRESSOR SWITCH
SERVICE VALVE LOW-PRESSURE SWITCH
DISCHARGE LINE
SUCTION LINE
COMPRESSOR HI-PRESSURE COMPRESSOR SWITCH
SERVICE VALVE LOW-PRESSURE SWITCH
DISCHARGE LINE SERVICE VALVE
SUCTION LINE
COMPRESSOR
SERVICE VALVE
Note: : Cooling
Model No.: TN-C2408T00 INDOOR COIL
OUTDOOR COIL HI-PRESSURE SWITCH
SERVICE VALVE LOW-PRESSURE SWITCH
DISCHARGE LINE
SUCTION LINE
COMPRESSOR HI-PRESSURE SWITCH
SERVICE VALVE LOW-PRESSURE SWITCH
DISCHARGE LINE SERVICE VALVE
SUCTION LINE
COMPRESSOR
SERVICE VALVE
Note: : Cooling
Ducted Split
3-25
Operation Range
TA5CUN2-01A
13. 2SHUDWLRQ 5DQJH &RROLQJ
2XWGRRU 8QLW > & '%@
&RQWLQXRXV RSHUDWLRQ
,QGRRU 8QLW > & '%@ $OWKRXJK ORZ DPELHQW NLW LV LQVWDOOHG LQ FDVH RXWGRRU WHPSHUDWXUH JRHV EHORZ & WKH FRROLQJ FDSDFLW\ FDQ EH GURSSHG DQG RSHUDWLRQ FKDUDFWHULVWLFV FDQ EH VOLJKWO\ GLIIHUHQW
3-26
Ducted Split
Operating Space Limitations
TA5CUN2-01A
14. Operating Space Limitations 14.1 Indoor units More than 910mm
More than 910mm
14.2 Outdoor units
more than 1200mm more than 900mm
more than 900mm
more than 900mm
more than 900mm
Ducted Split
3-27
Coefficient of Capacity Change
TA5CUN2-01A
15. The Coefficient of Capacity Change
Cap ac i t y (%)
100
LN-0380CC(25m) LN-0480CC/0580CC
90
TN-C1808T00 TN-C2408T00
80
70 7.5
10
20
25
30
40
50
Total pipe length(m)
Model
Pipe Size (Diameter:Ă˜)
Length(m)
Elevation(m)
Additional refrigerant Cycle No
Gas
Liquid
Standard
Max.
Standard
Max.
TN-C1808T00
9/8"
5/8"
7.5
50
7.5
30
180
2
TN-C2408T00
9/8"
5/8"
7.5
50
7.5
30
160
2
(g/m)
*If TN-C1808T00 Model is installed at a distance of 50m, for each cycle,7650g of refrigerant should be added (50-7.5) x 180g=7 650g *Capacity is based of standard length and maximum allowance length is on the basis of reliability. Notes: * Equivalent pipe length= Actual pipe length + number of bend x 0.3
3-28
Ducted Split
Mechanical Specifications
TA5CUN2-01A
16. Mechanical Specifications Mec hanical Specifications General Air handling units shall be completely factory asembled including coil drain pan, Blower motor and controls in an insulated casing that can be applied in horizontal or vertical configuration. Units shall be rated in accordance with ARI standard testing procedure, fully changed with R22. Units shall fully factory tested before shipment.
Casing Unit casing shall be constructed of having gauge zinc coated, galvanized steel. The cabinet shall be exterior painted and weather resistance. The condensing units shall have a water and air tight service panels with minimum number of screws per panel for easy servicing.
Compressors LG Ducted Split System units shall have direct drive hermetic compressor, reciprocating type with internal built in lubricating mechanism for all moving parts. Motor shall be suction gas cooled with internal temperature and over current sensitive motor over load, for maximum protection. Factory rubber shock mounted and internally spring isolation for sound and vibration control.
Refrigerant Circuits Each refrigerant circuit shall have an independent fixed capillary tube devices and service pressure ports, and refrigerant line filter(factory-installed) as standard.
Evaporator and Condenser Coils Shall be aluminum plate fins, mechanically bonded to copper tubes. Coil shall be factory tested for leakage and pressure.
Outdoor Fans Statically and dynamically, direct drive outdoor fan in vertical discharge position(Except 3RT). Permanently lubricated fan motors with built in thermal overload protection.
Indoor Fan Direct drive indoor fan for over 15RT units with forward curve centrifugal fans. Belt drive indoor fan for all models above 7.5RT. All motors shall be thermally overload protected.
Controls All units shall be controlled by thermostat. Time delay PCB shall provide time delay between Fan and Compressor.
Ducted Split
3-29
TA5CUN2-01A
Function of Remote Control
17. Function of Remote Control LCD Wired Remote Control
AUTO SWING
OPERATION
SET TEMP
SUB FUNCTION
Room Temp
1
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4
HI MED LO
Time Timer
Operation unit
On Off Set no. Time 01
03
Program set 05
07
09
11
13
15
17
19
21
23
3 17 6 7 8 9 10 11 12
2 4 Timer
Cancel
Program
Week
Hour
Min
5 Holiday
15
SET/CLR RESET
13
1. Operation display Displays the operation conditions. 2. On/Off Button Operation starts when this button is pressed, and stops when the button is pressed again. 3. Set Temperature Button Used to set the temperature when the desired temperature is obtained. 4. FAN Operation Button Used to circulate room air without cooling or heating. 5. Operation Mode Selection Button Used to select the operation mode. • Auto Operation Mode. • Cooling Operation Mode. • Soft Dry Operation Mode. 6.Electric Heater Button (HEAT PUMP MODEL ONLY) Used to set the Electric Heater.
14 16
9. Week Button Used to set a day of the week. 10. Program Button Used to set the weekly timer. 11. Holiday Button Used to set a holiday of the week. 12. Time Set Button Used to set the time of the day and change the time in the weekly timer Function. 13. Set and Clear Button Used to set and clear the weekly timer. 14. Room Temperature Checking Button Used to check the room temperature. 15. Humidity Button 16. Reset Button Used to set the current time and clear the setting time. 17. Operation Indicator
7. Timer Cancel Button Used to cancel the timer. 8. Timer Set Button Used to set the timer when the desired time is obtained. Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source. 3-30
Ducted Split
P/No.: MFL41387302
Head Office:
20 Yoidodong, Youngdungpogu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone:82-2-3777-7985
Tianjin Office:
Xing dian Road,Bei chen Dist, Tianjin,China. Phone:86-22-2690-3341 http://www.lge.com/airconditioner All rights reserved Printed in China August / 2008 The specifications, designs, and information in this brochure are subject to change without notice.
The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system.