Fan Coil Unit (Decorative Type) 50Hz 5CFBW-01A
General Description Thank you very much for your special patronage of LG air conditioners. LG's "Fan Coil Unit(Decorative type)" is one of the most widely used Air Conditioner. Being exposed in the ceiling or wall, it's appearance is splendid and this Fan Coil Unit is in accord with the Interior of the room. This unit emphasize that the edge of the unit express a contemporary feel as a design of curvaceousness. You can select various capacity's Decorative model such as a ceiling type and wall type with the capacity ranges from 300 CFM to 1,400 CFM. Apart from common features, this unit offers Light & Compact size, Quiet, Low-cost & Easy Installation, Efficient operation, Convenient Control like 3 step rotary switch or remote controller with controlling a interior temperature and etc. The decorative FCU is suitable for applications that require individual level air conditioning for buildings where there are many rooms or offices such as hotels, schools, public institutions and etc. This product and the interior on the room may harmonize with each other because this product have modern sensibility. A lot of information regarding the design & installation of this system is provided in this publication. This new products series contains data on the same pattern. Please utilize all the information for conducting your business efficiently. Make sure the specification, dimension or others technical data are same sa provideed in engineering data book before you start the project. We look forward to your continuing support.
LG Electronics Inc. Air Conditioning Company
3 Fan Coil Unit Air-Cooled Screw
Fan Coil Unit (Decorative type) 50Hz
Contents 1. Features & Benefits 2. Models List 3. Model Number Nomenclature 4. Specifications 5. Dimensional Drawings 6. Wiring Diagrams 7. Performance Data 8. Electric Characteristics 9. Sound Levels 10. Installation
4 Fan Coil Unit Air-Cooled Screw
1. Features & Benefits Decorative type fan coil units combine design flexibility with easy and low-cost installation. This model is exposed at the room like a stand type air conditioner. According to the load of requesting at the room, you can select from 300CFM to 1,400CFM capacities and you can also select types of Decorative model to the installation place such as the wall and ceiling. The units are ideal for installation in hotels, schools, public institutions that require individual control system.
LG decorative type fan coil unit provide for various benefits. 1. Quiet & Dependable performance. Decorative type fan coil unit delivers quiet and dependable air conditioning in a various range of capacities. You can select Air flow as 3 steps and It is also possible to control the room temperature automatically.
2. Splendid appearance & Compact size Decorative type fan coil unit express modern style look according to emphasize a design of curvaceousness. This unit also design compact size to reduce installation space.
3. Low cost installation. Each unit is designed to occupy a minimum space. This feature, along with convenient siring and piping connections, means reduces cost on renovations or new construction sites.
4. Efficient operation Electronically balanced centrifugal fan is connecting a direct driven with motor. It is possible to control fanÂ°Ă˜s on/off according to the room temperature (If you select the remote controller as a option). This is very efficient to operate the unit and also give the customers the optimum temperature.
5. Quality reduces service and maintenance expenses Motor/blower assembly can be easily removed from the unit for ease of service. Removing this assembly provides clear access to the entering air face of the coil, making coil cleaning a relatively simple matter. Removable panels make access to components and connections easy.
6. Component Features
General Furnish and install Fan Coil Units as indicated and scheduled in the plans. Units shall be factory assembled with coils that are pressure tested individually to 200 psi (1.6 MPa). The fans must be factory run and manufacturer must have a facility to test the capacity of cooling coils at specified entering air conditions and specified chilled water temperature, to assure correct capacity. In addition the test facility shall be suitable to test air capacity at specified external pressure drop at indicated speed setting.
Basic Unit The basic unit shall be fabricated out of 1mm galvanized steel GB/T 2518-2004 or above. The fan deck and the top of the coil section shall be lined with 5mm PE insulation. The fan motor shall be easily removable for serviceability. A terminal box with terminal strip shall be provided for terminating the wiring. On ceiling concealed units with plenum, the filter shall be easily removable from either side or the back. Standard filter shall be 10 mm nylon media and an optional filter with 10mm aluminium media shall also be available. Air Grill shall be made Plastic modular. Units with powder coating finish shall be available as an option.
5 Fan Coil Unit Air-Cooled Screw
1. Features & Benefits Coils Coils shall be made out of 3/8 inch or 9.52mm OD copper tubes. Aluminium fins shall be 0.105mm thick and the coil shall have maximum spacing of 2.4mm between the fins. The coil shall be pressure tested to 1.6 MPa (For a working pressure of 1600 kpa) and dehydrated before assembly. A manual air vent shall be provided on top of the coil. The coil assembly shall be protected on the side on which piping is to be fitted with a cover made of GI sheet. The metal sheet below the coil shall be powder coated to avoid corrosion.
Motors Motors shall be 3 speed, permanent split capacitor type with Thermal overload protection. Motors shall have permanently lubricated ball bearings. The motors shall have a class B insulation. Standard motor shall be IP20 is totally available on request. Motors shall be protected by an internal overload that is UL Certified component.
Fans Fans shall be centrifugal direct-drive, forward curved type. Fan wheel shall be statically and dynamically balanced.
Terminal Box All units shall be provided with factory installed terminal box with the fan motor wired to the box.
Drain Pan Drain Pan shall be weld steel, sloped to the piping connection, which will be threaded for easy connection. Internal surface shall be painted with anti-corrosive paint. The drain pan shall be insulated from below with PE insulation
Testing Manufacturer shall have a test facility to verify the air flow rate at specified external static pressure on all three speeds. It shall also be possible to verify the cooling capacity with water flow rates and temperature shown in the product guide. Verification of Airflow and Capacities shall be an option available at a declared cost. The manufacturing process should have a certified ISO 9,000 quality plan.
6 Fan Coil Unit Air-Cooled Screw
2. Models List Catagory
Floor Stand
Ceiling Suspended
Row
3
3
Nominal Capacity (CFM)
Model Name
300
YCNB036AA*0
220~240, 50, 1
400
YCNB046BA*0
220~240, 50, 1
600
YCNB066CA*0
220~240, 50, 1
800
YCNB086DA*0
220~240, 50, 1
1,000
YCNB106DA*0
220~240, 50, 1
1,200
YCNB126EA*0
220~240, 50, 1
1,400
YCNB146EA*0
220~240, 50, 1
300
YVNB036AA*0
220~240, 50, 1
400
YVNB046BA*0
220~240, 50, 1
600
YVNB066CA*0
220~240, 50, 1
800
YVNB086DA*0
220~240, 50, 1
1,000
YVNB106DA*0
220~240, 50, 1
1,200
YVNB126EA*0
220~240, 50, 1
1,400
YVNB146EA*0
220~240, 50, 1
7 Fan Coil Unit Air-Cooled Screw
Power Supply (V, Hz, Ø)
3. Model Number Nomenclature Y
C
N
B
0
3
6
A
A
B
0 .ANWSOKL
Suffix L:Supply water from left side (Face to the air outlet) R:Supply water from right side (Face to the air outlet) Development Sequence Function A : Basic B : Step Control E : Wired Remote Control Unit Type A : Mechanical Low Static (ST) B : Mechanical High Static (ST) C : Mechanical Low Static (DC) D : Mechanical High Static (DC) Chassis Type A : A Chassi s D : D Chassi s G : G Chassis K : K Chassis
B : B Chassi s E : E Chassi s H : H Chassi s L : L Chassis
C : C Chassis F : F Chassis J : J Chassis
Electric Standard (Volts / Freq. / Phase) 6 : 220~240V, 50Hz,1Ø 2 : 220~240V, 60Hz,1Ø Nominal Airflow 400 CFM 03 300 CFM 04 08 800 CFM 10 1,000 CFM 14 1,400 CFM 16 1,600 CFM 20 2,000 CFM
06 12 18
600 CFM 1,200 CFM 1,800 CFM
Coil Type A : 2 Row B : 3 Row C : 4 Row N:Indoor unit Type of Air Conditioner B : Cased Concealed Duct Type C : Decorative Floor Stand E : Uncased Concealed Duct Type (Exposed) V : Decorative Ceiling Suspended Type of Air Conditioner Y : LG Fan Coil Unit
8 Fan Coil Unit Air-Cooled Screw
4. Specifications 4.1 Decorative type (1/2) Indoor Unit Type
Decorative Type
Model Nominal Cooling Capacity
Btu/h kW
Water Flow Rate
GPM(l/min)
Water Pressure Drop Air Flow Rate
kPa High/Med/Low
CFM CMM
YCNB036AA*0
YCNB046BA*0
YCNB066CA*0
YCNB086DA*0
YVNB036AA*0
YVNB046BA*0
YVNB066CA*0
YVNB086DA*0
9,857 2.89 2.20 (8.3) 6.2 320/288/240 9.1/8.2/6.8
Type Class Fan Motor
Power Supply
V, Hz, Ø
Input Power
W
42
Capacitor
µF/Vac, EA
1.2/450, 1
1.8/450, 1
2.5/450, 1
No. Used
EA
1
1
1
Material Fan
Type
Noise Level
High/Med/Low
No. Used Tube Size
EA dB(A) inch(mm)
No. of Rows, Columns & FPI Coil
Drain Pan Filter
13,269 19,714 3.89 5.78 3.12 (11.8) 4.49 (17) 9.3 18.9 425/382/319 634/571/475 12/10.8/9 18/16.2/13.5 3-Speed Permanent Split Capacitor Motor B 220~240, 50, 1 55 91
Face Area
m2 (ft2)
Face Velocity
m/s (ft/s)
Water Content
l (gal, US)
2 39/32/26 3/8 (9.52) 3R, 8C, 11FPI 0.112 (1.2) 1.26 (4.13) 0.93 (0.25)
Material / Thickness Insulation (Material / Thickness) Material Q'ty
Dimensions (WxHxD) Body
EA mm inch
Net Weight
Body Water Inlet
inch(mm)
Piping Connection
Water Outlet
inch(mm)
Drain hose
kg(lbs)
Ø
2 958 x 483 x 232 38 x 19 x 9 20 (44.1) 3/4 (19.05) 3/4 (19.05) 20
26,159 7.66 6.25 (23.7) 27.2 846/762/635 24/16.2/18
125 2.5/450, 1 1.8/450, 1 2
Galvanized Steel Centrifugal Fan (Forward curved) 2 2 3 41/33/27 44/37/30 46/38/32 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3R, 8C, 11FPI 3R, 8C, 11FPI 3R, 8C, 11FPI 0.142 (1.53) 0.183 (1.97) 0.244 (2.63) 1.32 (4.33) 1.55 (5.09) 1.55 (5.09) 1.16 (0.31) 1.47 (0.39) 1.93(0.51) Galvanized Steel / T1.0 PE / T5.0 Synthetic Nylon(optinal Aluminum) 2 2 2 1,108 x 483 x 232 1,308 x 483 x 232 1,608 x 483 x 232 44 x 19 x 9 51 x 19 x 9 63 x 19 x 9 23 (50.7) 27 (59.5) 34 (75) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 20 20 20
Notes 1. Capacities are based on the following conditions: - Cooling : Entering air temperature 80.6°F (27°C)DB / 66.2°F (19°C) WB Entering water temperature 44.6°F (7°C) Water temperature rise 9°F (5°C) 2. Air Flow : Under dry coil conditions at 0 Pa external static pressure. 3. Due to our policy of innovation some specifications may be changed without notification.
9 Fan Coil Unit Air-Cooled Screw
4. Specifications 4.1 Decorative type (2/2) Indoor Unit Type
Decorative Type
Model
YCNB106DA*0
YCNB126EA*0
YVNB106DA*0
Nominal Cooling Capacity
Btu/h kW
Water Flow Rate
GPM(l/min)
Water Pressure Drop Air Flow Rate
kPa High/Med/Low
CFM CMM
Type Class Fan Motor
Power Supply
V, Hz, Ø
Input Power
W
Capacitor
µF/Vac, EA
No. Used
EA
Material Fan
Type
Noise Level
High/Med/Low
No. Used Tube Size
EA dB(A) inch(mm)
No. of Rows, Columns & FPI Coil
Drain Pan Filter
Face Area Face Velocity
m/s (ft/s)
Water Content
l (gal, US)
Material / Thickness Insulation (Material / Thickness) Material Q'ty
Dimensions (WxHxD) Body Net Weight Piping Connection
m2 (ft2)
Body
EA mm inch kg(lbs)
Water Inlet
inch(mm)
Water Outlet
inch(mm)
Drain hose
Ø
YCNB146EA*0
YVNB126EA*0 YVNB146EA*0 32,604 39,048 45,493 9.55 11.44 13.33 7.48 (28.3) 8.89 (33.7) 10.56 (40) 38.5 48 61 1,059/953/794 1,268/1,141/951 1,484/1,335/1,113 30/27/22.5 36/32.3/27 42/37.8/31.5 3-Speed Permanent Split Capacitor Motor B 220~240, 50, 1 151 161 168 2.5/450, 1 2.5/450, 2 3.0/450, 2 1.8/450, 1 2 2 2 Galvanized Steel Centrifugal Fan (Forward curved) 3 4 4 48/39/33 50/42/35 52/44/38 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3R, 8C, 11FPI 3R, 8C, 11FPI 3R, 8C, 11FPI 0.244 (2.63) 0.305 (3.28) 0.305 (3.28) 1.93 (6.33) 1.86 (6.10) 2.17 (7.12) 1.93(0.51) 2.39(0.63) 2.39(0.63) Galvanized Steel / T1.0 PE / T5.0 Synthetic Nylon(optinal Aluminum) 2 2 2 1,608 x 483 x 232 1,908 x 483 x 232 1,908 x 483 x 232 63 x 19 x 9 75 x 19 x 9 75 x 19 x 9 34 (75) 37 (81.6) 37 (81.6) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 20 20 20
Notes 1. Capacities are based on the following conditions: - Cooling : Entering air temperature 80.6°F (27°C)DB / 66.2°F (19°C) WB Entering water temperature 44.6°F (7°C) Water temperature rise 9°F (5°C) 2. Air Flow : Under dry coil conditions at 0 Pa external static pressure. 3. Due to our policy of innovation some specifications may be changed without notification.
10 Fan Coil Unit Air-Cooled Screw
5. Dimensional Drawings 5.1 Decorative type (Floor Stand)
[Unit : mm]
Model YCNB036AA*0 YCNB046BA*0 YCNB066CA*0 YCNB086DA*0 YCNB106DA*0 YCNB126EA*0 YCNB146EA*0
L
H
W
L1
Weight(kg) 3 Rows
958 1,108 1,308 1,608 1,608 1,908 1,908
483 483 483 483 483 483 483
232 232 232 232 232 232 232
672 822 1,022 1,322 1,322 1,622 1,622
20 23 27 34 34 37 37
11 Fan Coil Unit Air-Cooled Screw
5. Dimensional Drawings 5.2 Decorative type (Ceiling Suspended)
[Unit : mm]
Model YVNB036AA*0 YVNB046BA*0 YVNB066CA*0 YVNB086DA*0 YVNB106DA*0 YVNB126EA*0 YVNB146EA*0
L
H
W
L1
Weight(Kg) 3 Rows
958 1,108 1,308 1,608 1,608 1,908 1,908
483 483 483 483 483 483 483
232 232 232 232 232 232 232
672 822 1,022 1,322 1,322 1,622 1,622
20 23 27 34 34 37 37
12 Fan Coil Unit Air-Cooled Screw
6. Wiring Diagrams
Model : Y*NB036AAE0 Y*NB046BAE0 Y*NB066CAE0 Y*NB086DAE0
AIR CONDITIONER
OFF
HI
MED
OFF
Y*NB106DAB0 Y*NB126EAB0 Y*NB146EAB0
GND L
L
N
N
L LO MED HI
Power source 1Ø,220~240V,50Hz
LO
Model : Y*NB036AAB0 Y*NB046BAB0 Y*NB066CAB0 Y*NB086DAB0
N LO MED
FC
HI
Y*NB106DAE0 Y*NB126EAE0 Y*NB146EAE0
L
L
N
N HI MED LOW VAL1 VAL2
13 Fan Coil Unit Air-Cooled Screw
N HI MED LOW VAL1
FC
Power source 1Ø,220~240V,50Hz
GND
7. Performance Data • Decorative type
* ESP = 0 Pa
Air Flow Model
YCNB036AA*0 YVNB036AA*0 YCNB046BA*0 YVNB046BA*0 YCNB066CA*0 YVNB066CA*0 YCNB086DA*0 YVNB086DA*0 YCNB106DA*0 YVNB106DA*0 YCNB126EA*0 YVNB126EA*0 YCNB146EA*0 YVNB146EA*0
Speed High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low
Cooling capacity
CMH
Total (kW)
544 490 408 722 650 542 1,078 970 808 1,439 1,295 1,079 1,800 1,620 1,350 2,156 1,940 1,617 2,522 2,270 1,892
2.89 2.60 2.17 3.89 3.50 2.92 5.78 5.20 4.33 7.67 6.90 5.75 9.56 8.60 7.17 11.44 10.30 8.58 13.33 12.00 10.00
Air off FCU
Btu/h
Sensible (kW)
DB (°C)
WB (°C)
9,861 8,871 7,404 13,273 11,942 9,963 19,721 17,742 14,774 26,170 23,543 19,619 32,619 29,343 24,464 39,033 35,144 29,275 45,482 40,944 34,120
1.98 1.78 1.50 2.78 2.47 2.07 4.16 3.74 3.07 5.46 4.90 4.05 6.92 6.18 5.11 7.82 7.11 5.91 9.32 8.40 7.07
14.38 14.41 14.25 13.73 13.86 13.81 13.70 13.70 13.86 13.89 13.92 14.02 13.75 13.83 13.92 14.39 14.28 14.32 14.19 14.17 14.06
13.33 13.46 13.48 12.73 12.94 13.07 12.70 12.79 13.11 12.88 12.99 13.27 12.76 12.92 13.18 13.34 13.33 13.55 13.19 13.26 13.33
Notes 1. Capacities are based on the following conditions: - Cooling : Entering air temperature 80.6°F (27°C)DB / 66.2°F (19°C) WB Entering water temperature 44.6°F (7°C) Water temperature rise 9°F (5°C)
14 Fan Coil Unit Air-Cooled Screw
Water flow CMH
GPM (US)
Water flow Pressure (kPa)
0.50 0.45 0.37 0.71 0.60 0.50 1.02 0.90 0.75 1.42 1.19 0.99 1.70 1.48 1.23 2.02 1.77 1.48 2.40 2.07 1.72
2.20 1.97 1.65 3.12 2.65 2.21 4.49 3.94 3.28 6.25 5.23 4.36 7.48 6.52 5.44 8.89 7.81 6.51 10.56 9.10 7.58
6.2 5.6 4.6 9.3 7.9 6.6 18.9 16.6 13.8 27.2 22.8 19.0 38.5 33.6 28.0 48.0 42.2 35.1 61.0 52.6 43.8
8. Electric Characteristics • Decorative type Power Supply 1Phase, 220~240V, 50Hz Model YCNB036AA*0 YVNB036AA*0 YCNB046BA*0 YVNB046BA*0 YCNB066CA*0 YVNB066CA*0 YCNB086DA*0 YVNB086DA*0 YCNB106DA*0 YVNB106DA*0 YCNB126EA*0 YVNB126EA*0 YCNB146EA*0 YVNB146EA*0
Motor
Masimum Absorbed Power(each) WATT
NO. of Motors
F.L.A(A.M.P)
44
1
0.20
1
3
58
1
0.26
1
3
96
1
0.44
1
3
131
2
0.60
1
3
158
2
0.72
1
3
169
2
0.77
1
3
176
2
0.80
1
3
R.C.S mm2
R.C.B(AMP)
The LG Fan Coil unit is equipped with three-speed, permanent split capacitor motor
Internal Thermal All motors are equipped with internal Thermal overloads. Overload Motor Bearings
The motors have permanently lubricated ball bearings as a standard offering.
Insulation
The motors are provided with class B insulation.
Degree of Protection
The degree of protection is specified in accordance with DIN 40050 with publication of the IEC by means of the letter IP (Internal Protection) and a two characteristic numerals as stated in the standard. For all the motors, IP20 protection is provided as standard.
Legend : • FLA : Full Load Ampere ( For each motor)
• R.C.S : Recommended Cable Size
• R.C.B : Recommended Standard Circuit Breaker
• Motor : Nameplate AMPs may vary
15 Fan Coil Unit Air-Cooled Screw
9. Sound Levels Overall Notes: - Sound measured at 1.4m away from the center of the unit. - Data is valid at free field condition - Data is valid at nominal operation condition - Reference acoustic pressure 0dB = 20µPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard.
Ceiling
1.4m
Wall
1.4m
• Decorative type Model Name YCNB036AA*0 YVNB036AA*0 YCNB046BA*0 YVNB046BA*0 YCNB066CA*0 YVNB066CA*0 YCNB086DA*0 YVNB086DA*0 YCNB106DA*0 YVNB106DA*0 YCNB126EA*0 YVNB126EA*0 YCNB146EA*0 YVNB146EA*0
Sound Level[dB(A)] H
M
L
39
32
26
41
33
27
44
37
30
46
38
32
48
39
33
50
42
35
52
44
38
16 Fan Coil Unit Air-Cooled Screw
10. Installation Preparation
WARNING • Load bearing of the installation place should be sufficient, in case of falling of air conditioner. • Guard against gale, earthquake. Installation should be carried out as stated in case of accident.
1) Receiving goods and testing When units are delivered to ordered site, user should open the box to inspect them and receive them. - Inspecting if the specification is ready - Checking unit type, specification and accessories - Checking if unit is damaged and parts are all ready If it is damaged or you have any doubts, please contact with distributor ASAP, to solve the problems.
2) Moving When moving the units with forkman or others, anti-vibration measures should be adopted in case of collision. The unit should keep horizontal, angle of incline can’t be more than 30°.
3) Store of the units Location : far from light, rain, sand, stone and wind Temperature : max. 60°, min. -10° Humidity : max. 90%
Installation of units When the site of installation is located, please do as follows 1) Dig a hole through the wall, which should be inclined outward and downward, and the incline angle should be more than 1%. Then thread inlet/outlet water connecting pipe and wire connecting pipe through a nativepurchased PVC through-wall pipe. 2) Make sure that no pipeline or steel bar is in the way of digging. 3) The cover of exposed units should be removed on installation. And pay attention not to damage the cover. 4) To suspended units the units should be hung on a firm and horizontal rooftop. If its base is infirm, there will be noise, vibration and leakage. To floor units£¨the units should be fixed on plastic feet and then connected to side wall. If its base is infirm, there will be noise, vibration and leakage. 5) Please use suspended screw of M8 or M10 (4 pcs, provide by yourself) (using M10 when the height of suspended screw is more than 0.9m). And compute interval according to dimension of installation hole. 6) Units and inlet/outlet pipe should be connected with flexible metal tubes to absorb vibration. 7) Inlet and outlet of the units should be installed with filter, avoiding blocking the cooper tubes on heat exchanger. 8) Condensed water pipe should be inclined for discharging of condensed water. 9) Heat preservation should be done to inlet/outlet pipe and condensed water pipe. The wall of pipe should be not less than 15mm in thickness.
17 Fan Coil Unit Air-Cooled Screw
10. Installation 10) Electric connection should be accurate, safe and well-grounding.
[Floor Stand]
[Ceiling Suspended]
Instruction of 2-pipe thermostat 1) Thermostat should be installed on the wall that can reflect temperature indoor or inside area, with the height of about 1.4 meters above the ground. Direct sunshine and heat-generation appliances should be avoided. 2) The thermostat consists of three parts, bottom shell and small box. Separate it with a small screwdriver by prizing lightly the clip on the top of the thermostat. Refer to the wiring diagram first and connect the ends of the box steadily with wire. After assembling with the bottom shell, lead the tier wire out through the square hole and fix with M4 screws onto the standard box on the wall. 3. Connect the plug of tier wire with the socket of the face shell and after checking, button up the lower side of the face shell and then the upper side until a “ka� sound is heard, which means installation finished.
Heating mode
Wind valve on mode
The outer shell Timing function on
Lock mode
LCD
Cooling mode Automation mode
S1: On/Off key, Confirm key
S4: Functions exchanging key
S2: Temperature, time, parameter down key
S3: Temperature, time, parameter eters up key
The displaying number
Figure1
18
Off mode
The temperature difference
Figure2
18 Fan Coil Unit Air-Cooled Screw
Installation
P/No.: MFL62537704
Air Conditioner 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea. http://www.lgeaircon.com
All rights reserved Printed in Korea May/2009 The specifications, designs, and information in this brochure are subject to change without notice.
The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system.