GAZOR
Direct DX commercial
Ceiling Mounted Cassette Unit R22/50HZ Notes: 1.Cooling Mode: Indoor DB=27℃,WB=19℃;Outdoor DB=35℃,WB=24℃. 2.Heating Mode: Indoor DB=20℃;Outdoor DB=7℃, WB=6℃. Model Power Supply
KFR-35QW
KFR-50QW
V/Ph/Hz
KFR-70QW
KFR-100QW
KFR-120QW
220/1/50
KFR-140QW
380/3/50
BTU
12000
18000
24000
36000
42000
48000
W
3500
5000
7000
10000
12000
14000
Heating
BTU
13000
19000
26000
38000
45000
52000
Cooling
W
1250
1820
2500
3800
4700
4900
Heating
W
1250
1820
2500
3900
4500
4900
Cooling
A
5.9
8.6
11.8
6.5
7.4
7.4
Heating
A
5.9
8.6
11.8
6.7
7.4
7.4
Indoor
dB(A)
34
36
41
43
48
48
Outdoor
dB(A)
48
56
56
58
60
60
Air circulation
m3/h
500
800
1150
1400
1700
1700
Suitable Area
m2
14-24
22-34
30-50
45-65
60-90
70-100
Capacity
Input power Running current Noise
Cooling
Indoor unit main
Net
mm
590x590x260
590x590x260
840x840x240
840x840x240
840x840x240
840x840x240
machine dimension
Shipping
mm
675x675x310
675x675x310
885x885x260
885x885x260
885x885x260
885x885x260
Indoor unit
Net
mm
650x650x30
650x650x30
950x950x45
950x950x45
950x950x45
950x950x45
panel dimension
Shipping
mm
720x720x135
720x720x135
1005x1005x100
1005x1005x100
1005x1005x100
1005x1005x100
Outdoor unit
Net
mm
760x255x525
850x290x580
865x310x710
890x340x1080
910x340x1080
910x340x1080
dimension
Shipping
mm
890x360x590
995x390x650
1025x395x790
1060x440x1240
1080x440x1240
1080x440x1240
GAZOR
Direct DX commercial
Ceiling & floor Unit
R22/50HZ
Notes: 1.Cooling Mode: Indoor DB=27℃,W B=19℃;Outdoor DB=35℃,W B=24℃. 2.Heating Mode: Indoor DB=20℃;Outdoor DB=7℃, W B=6℃
Model Capacity
BTU
Power Supply Rated Capacity Rated input power Rated input current Noise Level
Packing dimension
KFR-50DW
KFR-70DW
KFR-100DW
KFR-140DW
KFR-170DW
12000
18000
24000
36000
48000
60000
V/Ph/Hz
220/1/50
380/3/50
Cooling
W
3500
5000
7000
10000
14000
17000
Heating
BTU
13000
19000
26000
38000
52000
61500
Cooling
W
1250
1820
2500
3800
4900
6200
Heating
W
1250
1820
2500
3900
4900
6200
Cooling
A
5.9
8.6
11.8
6.5
7.4
9.4
Heating
A
5.9
8.6
11.8
6.7
7.4
9.4
Indoor
dB(A)
34
36
41
43
48
49
Outdoor
dB(A)
48
56
56
58
60
60
m3/h
600
800
1200
1400
1900
2300
Indoor
mm
905x673x243
905x673x243
1288x673x243
1288x673x243
1672x673x243
1672x673x243
Outdoor
mm
760x255x525
850x290x580
865x310x710
930x350x920
910x340x1080
910x340x1330
Indoor
mm
995x765x311
995x765x311
1375x765x311
1375x765x311
1760x765x311
1760x765x311
Outdoor
mm
890x360x590
995x390x650
1025x395x790
1105x435x1120
1080x440x1240
1080x440x1490
Air Flow Volume Net dimension
KFR-35DW
GAZOR
Direct DX commercial
Low Static Pressure Duct Unit R22/50HZ Notes: 1.Cooling: Indoor DB=27℃,W B=19℃;Outdoor DB=35℃,W B=24℃. 2.Heating: Indoor DB=20℃;Outdoor DB=7℃, W B=6℃.
Model
GR-25A
GR-35A
GR-50A
GR-72A
GR-100A
GR-120SA
BTU
9,000
12,000
18,000
24,000
36,000
42,000
Rated Cooling capacity
W
2500
3500
5000
7200
10000
12000
Rated Heating capacity
W
2750
3800
5500
7800
11000
13000
m3/h
480
720
960
1400
1920
2400
20
30
30
30
Capacity
Air Flow Volume External Static Pressure
Pa
12
Cooling
W
920
1270
1850
3000
3800
5040
Heating
W
840
1250
1800
2800
3600
4500
Rated Input
Cooling
A
4.3
6.1
8.7
13.8
17.4
10.2
Current
Heating
A
4.0
6.0
8.5
12.9
17.0
9.0
Outdoor
dB(A)
53
56
57
58
59
61
Indoor
dB(A)
41
43
45
48
49
50
Indoor
mm
1010x565x200
1010x565x200
1210x565x200
1580x475x235
1780x475x235
1940x475x235
Outdoor
mm
820x320x530
820x320x530
870x370x685
930x372x732
980x370x685
1010x442x1100
Indoor
kg
16
18
20
28
34
38
Outdoor
kg
25
41
47
66
96
130
Liquid
mm
Gas
mm
Rated Input Power
Noise Level Dimensions Weight Pipe Diameter Refrigerant Amt (R22)
kg
6.0x0.8 9.52x0.8 0.68
12.7x0.8 1.15
1.25
2
9.52x0.8
12.7x0.8
15.88x1.0
19.05x1.0 1.7
2.9
GAZOR
Direct DX commercial
High Static Pressure Unit R22/50HZ Notes: 1.Cooling Mode: Indoor DB=27℃,WB=19℃;Outdoor DB=35℃,WB=24℃. 2.Heating Mode: Indoor DB=20℃;Outdoor DB=7℃, WB=6℃.
Model Capacity
BTU
Power Capacity
GR75HSA
GR120HSA
GR200HS
GR250HS
GR30HS
GR400HS
GR500HS
25,000
42,000
62,000
85,000
102,000
140,000
170,000
V/Ph/Hz
380/3/50
Cooling
KW
7.5
12
20
25
30
40
50
Heating
KW
8.5
13
23
28
33
43
53
m3/h
1500
2500
4000
5400
6800
7500
10500
Pa
70
80
120
100
120
150
200
Air Flow Volume Static pressure Input
Cooling
KW
2.8
4.6
7.8
9.6
11.7
15.7
20
Power
Heating
KW
2.7
4.4
7.4
9.3
11.5
15.2
19.5
Input
Cooling
A
6.5
10.7
16
19.4
22.8
27.6
33.8
Current
Heating
A
6.2
10.3
15
19.2
22.4
26.7
33
Indoor
dB(A)
50
50
53
54
65
66
68
Outdoor
dB(A)
52
60
62
62
66
67
70
Indoor
Kg
42
55
95
95
125
150
180
Outdoor
kg
75
130
220
250
250
200+200
230+230
Noise Weight
Refrigerant Type
R22
Indoor Dimension
mm
850x700x450
1000x875x460
1400x875x460
1400x875x590
1750x875x590
2020x99-x688
2170x990x788
Outdoor Dimension
mm
950x340x850
950x395x1150
1280x690x1300
1280x690x1540
1403x821x924
(1280x690x1300)x2
(1280x690x1540)x2
GAZOR
Direct DX commercial
Multi Duct Unit Outdoor 1:2 system
Model
Indoor unit
DLR-28/28A
DLR-35/35A
DLR-50/50A
DLR60/60A
Outdoor unit
DLR-28/28WA
DLR-35/35WA
DLR-50/50WA
DLR60/60WA
Rated cooling Capacity
W
2800x2
3500x2
5000x2
6000x2
Rated heating Capacity
W
3100x2
3800x2
5500x2
6500x2
Rated Cooling input power
W
2200
2800
3800
4700
Rated heating input power
W
2200
2600
3700
4600
Rated cooling input current
A
10.4
12.6
18.0
22.4
Rated heating input current
A
10.4
12.4
17.6
21.8
Liquid
mm
6.35/6.35
6.35/6.35
6.35/6.35
9.52/9.52
Gas
mm
9.52/9.52
9.52/9.52
12.7/12.7
15.88/15.88
Connect pipe Refrigerant Type
R22
Charge Amount
kg
0.98x2
1.15x2
1.25x2
1.7x2
Net Weight
kg
55
90
130
130
Noise Level
dB(A)
60
61
62
62
Dimension
mm
870x370x685
950x410x850
950x410x1250
950x410x1250
GAZOR
Direct DX commercial
Outdoor Unit 1:3 system
Model
Indoor unit
DLR-35/35/35A
DLR-28/35/50A
DLR-35/35/50A
Outdoor unit
DLR-35/35/35WA
DLR-28/35/50WA
DLR-35/35/50WA
Rated cooling Capacity
W
3500x3
2800+3500+5000
3500x2+5000
Rated heating Capacity
W
3800x3
3100+3800+5500
3800x2+5500
Rated Cooling input power
W
4200
4400
4700
Rated heating input power
W
3900
4250
4450
Rated cooling input current
A
18.9
20.5
21.6
Rated heating input current
A
18.6
20.2
21.2
Liquid
mm
6.35/6.35/6.35
6.35/6.35/6.35
6.35/6.35/6.35
Gas
mm
9.52/9.52/9.52
9.52/9.52/12.7
9.52/9.52/12.7
Connect pipe Refrigerant Type
-
R22
Charge Amount
kg
1.15x3
0.98+1.15+1.25
1.15x2+1.25
Net Weight
kg
130
135
135
Noise Level
dB(A)
61
62
62
Dimension
mm
940x410x1250
940x410x1250
940x410x1250
GAZOR
Direct DX commercial
Outdoor Unit 1:4, 1:5 system
Model
Indoor unit
DLR-35/35/35/35A
DLR-28/35/35/50A
DLR-28/28/35/72A
DLR-28/28/35/50/50A
Outdoor unit
DLR-35/35/35/35WA
DLR-28/35/35/50WA
DLR-28/28/35/72WA
DLR-28/28/35/50/50WA
Rated cooling Capacity
W
3500x4
2800+3500x2+5000
2800x2+3500+7200
2800x2+3500+5000x2
Rated heating Capacity
W
3800x4
3100+3800x2+5500
3100x2+3800+7800
3100x2+3800+5500x2
Rated Cooling input power
W
5600
5800
6300
7400
Rated heating input power
W
5200
5550
6000
7200
Rated cooling input current
A
25.2
26.8
29.3
34.7
Rated heating input current
A
24.8
26.4
29.0
34.2
Liquid
mm
6.35/6.35/6.35/6.35
6.35/6.35/6.35/6.35
6.35/6.35/6.35/9.52
6.35/6.35/6.35/6.35/6.35
Gas
mm
9.52/9.52/9.52/9.52
9.52/9.52/9.52/12.7
9.52/9.52/9.52/15.88
9.52/9.52/9.52/12.7/12.7
Connect pipe Refrigerant Type
R22
Charge Amount
kg
1.15x4
0.98+1.15x2+1.25
0.98x2+1.15+2.0
0.98x2+1.15x1.25x2
Net Weight
kg
220
220
230
250
Noise Level
dB(A)
62
63
63
65
Dimension
mm
1300x530x1420
1300x530x1420
1490x530x1420
1490x530x1420
Indoor Unit Model
DLR-28A
DLR-35A
DLR-50A
DLR-60A
DLR-72A
Cooling capacity
W
2,800
3,500
5,000
6,000
7,200
Heating Capacity
W
3,100
3,800
5,500
6,500
7,800
Air Flow Volume
m3/h
600
720
1,050
1,050
1,400
Noise Level
dB(A)
42
43
45
46
48
Dimension
mm
980x475x235
980x475x235
1160x475x235
1160x475x235
1580x475x235