Technical Data Sheet of Harvest Gas Boiler Hot Water + Room Heating

Room Heting Only

2 x separate heat exchanger (with PHE)

1 x double-pipe Heat Exchange SL-T(X)28 SL-TX18 SL-TX24 X = A/B/C/D/E/F/G/H/I/J/K/L 20 26.3 29.8 17.8 23.7 27.8 5.3 11.2 12 4.2 9.3 10.5 89 90.1 93.3

SL-NX18 SL-NX24 SL-NX28 X = A/B/C/D/E/F/G/H/I/J/K/L 20 26.3 29.8 17.8 23.7 27.8 5.3 11.2 12 4.2 9.3 10.5 89 90.1 93.3

Model

Unit

Rated Input Power Rated Output Power Min. Input Power Min. Output Power Reate Heating Efficiency Heating System Water Temp. Adjustable Radiator Range Floor Heating Max./Min. System Pressure Normal Suitable Heating Area Heightest Water Temp. Capacity Expansion Tank Initianl Pressure Domestic Water System Hot Water Production Capacity (t=25℃) Water Temp. Adjustable Range (±3℃) Minimum Start Water Flow Max Water Supply Pressure Min. Electrical Power Supply Rated Electric Power Protection Grade Gas Rated Pressure Natural Gas Consumption Rated Pressure LPG Consumption Artificial Coal Gas Rated Pressure Port Size Heating water in/out port Domestic water in/out port Gas in port Others Co-axie Discharge/Suction Chimney Net Dimension (HxWxD) Net/Gross Weight

KW KW KW KW %

SL-DX18 SL-DX24 SL-DX28 X = A/B/C/D/E/F/G/H/I/J/K/L 20 26.3 29.8 17.8 23.7 27.8 5.3 5.5 5.8 4.2 4.6 5 89 90.1 93.3

℃ ℃ MPa MPa

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

30~80 25~60 0.05~0.3 0.1~0.12

㎡ ℃ L MPa

60~120 90 6 0.1

60~200 90 6 0.1

80~250 90 8 0.1

60~120 90 6 0.1

60~200 90 6 0.1

80~250 90 8 0.1

60~120 90 6 0.1

60~200 90 6 0.1

30~80 25~60 0.05~0.3 0.1~0.12 80~250 90 8 0.1

L/min ℃ L/min MPa MPa

10 30~60 2 0.7 0.05

13.6 30~60 2 0.7 0.05

16 30~60 2 0.7 0.05

10 30~60 2 0.7 0.05

13.6 30~60 2 0.7 0.05

16 30~60 2 0.7 0.05

10 30~60 2 0.7 0.05

13.6 30~60 2 0.7 0.05

16 30~60 2 0.7 0.05

V/Hz W IP

220/50 100 X4D

220/50 110 X4D

220/50 120 X4D

220/50 100 X4D

220/50 110 X4D

220/50 120 X4D

220/50 100 X4D

220/50 110 X4D

220/50 120 X4D

Pa m /h Pa kg/h Pa

2000 1.02~2.2 2800 0.8~1.75 1000

2000 1.23~2.60 2800 1.00~2.10 1000

2000 1.43~3.03 2800 1.16~2.45 1000

2000 1.02~2.2 2800 0.8~1.75 1000

2000 1.23~2.60 2800 1.00~2.10 1000

2000 1.43~3.03 2800 1.16~2.45 1000

2000 1.02~2.2 2800 0.8~1.75 1000

2000 1.23~2.60 2800 1.00~2.10 1000

2000 1.43~3.03 2800 1.16~2.45 1000

inch inch inch

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

G3/4 G1/2 G3/4

mm mm kg

φ60/φ100 730×460×256 35/38.5

φ60/φ100 730×460×256 36.5/40

φ60/φ100 730×460×322 42.5/46

φ60/φ100 730×460×256 35/38.5

φ60/φ100 730×460×322 36.5/40

φ60/φ100 730×460×322 42.5/46

φ60/φ100 730×460×256 35/38.5

φ60/φ100 730×460×256 36.5/40

φ60/φ100 730×460×322 42.5/46