Code : MCC-2007-0001 Date : 21-08-2007 Superceded : nil
Amendment Sheet Nomenclature Product Line Up Outdoor Unit
010C 015C
Cooling Model
020C
025C
028C
035C 040C 050C 061C 010CR 015CR
Heat Pump Model
020CR
025CR
028CR
035CR
040CR 050CR 061CR
ACPOA ACPIB ACPOC ACPIA ACPOA FCPOC FCPIC ACPIA ACPOA FCPOC PCPIC ACPOA ACPIA FCPOA FCPIA ACCOB FCCGB FCCOB FCCOA FCCGA ACCGA FCCOA FCCGA FCCGA ACPOA ACPIB ACPOC ACPIA ACPOC FCPOC FCPIC ACPIA ACPOC FCPOC FCPIC ACPOA ACPIA FCPOA FCPIA ACCOB ACCGB FCCOB FCCGB ACCGA FCCOA FCCGA FCCOA FCCGA FCCGA
X
X
X X X X
X X X X X X X X
X X X X
X X X X X X X X X X X
X X X X X X X X X
X X X X X X X X X
X X X
X X X X X X X X X
X X X X X X
X X X X X X X X X X X X X X X
X X X X X
X X
X X
X X
X X
X X X X X X X X X X X X
X X
X X X X X X X X X
X X X X X
X X X X X X X X X X
X X X X X X X X X X
X
X X
X X
X X X X X
X X X X X
X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
ETL
CE Marking
Marking
Compressor X X X X X X X X X X X X X X X
X
X X
Rotary
Copeland Scroll Comp.
Grille Drain Elbow
Phase Sequencer
Nantong Press. SW
Low Pressure Switch
High Pressure Switch
Contactor
Safety Devices
Low Ambient Kit
High Ambient Kit
Gold Fin
Special
Refrigerant Ctrl + Fin X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
TXV
Cap. Tube
M5LC
Nomenclature
Classification
Application Information Refrigerant Circuit Diagrams Indoor Unit : M5CC 038 C Outdoor Unit : M5LC 035 C
Indoor Unit : M5CC 038 CR Outdoor Unit : M5LC 035 CR
Engineering and Physical Data General Data – Cooling Only (R410A) INDOOR UNIT
MODEL
M5CC 038C M5LC 035C
OUTDOOR UNIT
NOMINAL CAPACITY - 1Ø / <3Ø>
Btu/h
32000 / <33000>
W
9380 / <9670>
NOMINAL TOTAL INPUT POWER - 1Ø / <3Ø>
W
3287 / <3427>
NOMINAL RUNNING CURRENT - 1Ø / <3Ø>
A
15.2 / <5.9>
V/Ph/Hz
220 - 240 / 1 / 50 / <380 - 415 / 3 / 50>
W/W
3.07 / <3.03>
POWER SOURCE - 1Ø / <3Ø> EER - 1Ø / <3Ø>
R410A
REFRIGERANT TYPE
OUTDOOR CAP. TUBE
REFRIGERANT CONTROL (EXPANSION DEVICE) CONTROL
INDOOR UNIT
SLM WIRED HANDSET
OPERATION SUPER HIGH
l/s / CFM
604 / 1280
HIGH
l/s / CFM
547 / 1160
MEDIUM
l/s / CFM
496 / 1050
LOW
l/s / CFM
434 / 920
Pa
118 / 96 / 78 / 61
dBA
52 / 49 / 47 / 45
AIR FLOW
EXTERNAL STATIC PRESSURE (H/M/L) SOUND PRESSURE LEVEL (H/M/L) UNIT DIMENSION
PACKING DIMENSION
HEIGHT
mm/in
305 / 12.0
WIDTH
mm/in
1302 / 51.3 638 / 25.1
DEPTH
mm/in
HEIGHT
mm/in
355 / 14.0
WIDTH
mm/in
1461 / 57.5
DEPTH
mm/in
727 / 28.6
WEIGHT CONDENSATE DRAIN SIZE AIR FLOW
UNIT DIMENSION
PACKING DIMENSION
kg/lb
41 / 90
mm/in
19.1 / 3/4
l/s / CFM
1605 / 3400
dBA
58
HEIGHT
mm/in
850 / 33.5 1030 / 40.6
SOUND PRESSURE LEVEL OUTDOOR UNIT
DUCTED
AIR DISCHARGE
WIDTH
mm/in
DEPTH
mm/in
400 / 15.8
HEIGHT
mm/in
1000 / 39.4
WIDTH
mm/in
1200 / 47.2
DEPTH
mm/in
560 / 22.1
UNIT WEIGHT
kg/lb
PIPE CONNECTION
SIZE
95 / 209 FLARE VALVE
TYPE LIQUID
mm/in
9.5 / 3/8
GAS
mm/in kg/lb
15.9 / 5/8 2.6 / 5.73
REFRIGERANT CHARGE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151. 5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER / COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253
General Data – Heat Pump (R410A) M5CC 038CR
INDOOR UNIT
MODEL
M5LC 035CR
OUTDOOR UNIT
32000 / <33000>
Btu/h
NOMINAL COOLING CAPACITY - 1Ø / <3Ø> NOMINAL HEATING CAPACITY - 1Ø / <3Ø>
W
9380 / <9670>
Btu/h
34000 / <36000>
W
9960 / <10550>
NOMINAL TOTAL INPUT POWER (COOLING) - 1Ø / <3Ø>
W
3287 / <3427>
NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>
W
2987 / <3137>
NOMINAL RUNNING CURRENT (COOLING) - 1Ø / <3Ø>
A
15.2 / <5.9>
NOMINAL RUNNING CURRENT (HEATING) - 1Ø / <3Ø>
A
14.0 / <5.5>
V/Ph/Hz
220 - 240 / 1 / 50 / <380 - 415 / 3 / 50>
EER - 1Ø / <3Ø>
W/W
3.07 / <3.03>
COP - 1Ø / <3Ø>
W/W
3.62 / <3.64>
POWER SOURCE - 1Ø / <3Ø>
R410A
REFRIGERANT TYPE
OUTDOOR CAP. TUBE
REFRIGERANT CONTROL (EXPANSION DEVICE) CONTROL
INDOOR UNIT
SLM WIRED HANDSET
OPERATION SUPER HIGH
l/s / CFM
603 / 1280
HIGH
l/s / CFM
546 / 1160
MEDIUM
l/s / CFM
495 / 1050
LOW
l/s / CFM
433 / 920
Pa
118 / 96 / 78 / 61
dBA
52 / 49 / 47 / 45
AIR FLOW
EXTERNAL STATIC PRESSURE (H/M/L) SOUND PRESSURE LEVEL (H/M/L) UNIT DIMENSION
PACKING DIMENSION
HEIGHT
mm/in
305 / 12.0
WIDTH
mm/in
1302 / 51.3 638 / 25.1
DEPTH
mm/in
HEIGHT
mm/in
355 / 14.0
WIDTH
mm/in
1461 / 57.5
DEPTH
mm/in
727 / 28.6
WEIGHT CONDENSATE DRAIN SIZE AIR FLOW
UNIT DIMENSION
PACKING DIMENSION
kg/lb
41 / 90
mm/in
19.1 / 0.75
l/s / CFM
1605 / 3400
dBA
58
HEIGHT
mm/in
850 / 33.5 1030 / 40.6
SOUND PRESSURE LEVEL OUTDOOR UNIT
DUCTED
AIR DISCHARGE
WIDTH
mm/in
DEPTH
mm/in
400 / 15.8
HEIGHT
mm/in
1000 / 39.4
WIDTH
mm/in
1200 / 47.2
DEPTH
mm/in
560 / 22.1
UNIT WEIGHT
kg/lb TYPE
PIPE CONNECTION
SIZE
95 / 209 FLARE VALVE
LIQUID
mm/in
9.5 / 3/8
GAS
mm/in kg/lb
15.9 / 5/8 2.6 / 5.73
REFRIGERANT CHARGE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151. 5) EFFECTIVE POWER IS USED IN THE RATED EER / COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253.
Performance Data R410A Models (Cooling Only) Indoor Unit : M5CC 038 C Outdoor Unit : M5LC 035 C Outdoor DB째C ID DB째C 20
24
28
30
ID WB째C 15 16 16 17 18 19 20 18 19 20 21 22 23 24 20 21 22 23 24
20 TC(kW) 9.843 10.221 10.221 10.599 10.940 11.269 11.616 10.940 11.269 11.616 11.952 12.289 12.625 12.961 11.616 11.952 12.289 12.625 12.961
25 SC(kW) 6.262 5.936 7.966 7.640 7.277 6.912 6.526 9.307 8.942 8.556 8.169 7.781 7.393 7.006 9.572 9.184 8.796 8.409 8.021
TC(kW) 9.344 9.740 9.740 10.136 10.469 10.737 11.109 10.469 10.737 11.109 11.416 11.723 12.030 12.337 11.109 11.416 11.723 12.030 12.337
30 SC(kW) 5.764 5.500 7.531 7.267 6.940 6.604 6.142 8.971 8.635 8.173 7.702 7.230 6.759 6.288 9.188 8.717 8.246 7.775 7.303
TC(kW) 8.926 9.299 9.299 9.672 9.998 10.204 10.601 9.998 10.204 10.601 10.879 11.157 11.435 11.713 10.601 10.879 11.157 11.435 11.713
35 SC(kW) 5.347 5.105 7.136 6.894 6.604 6.297 5.759 8.635 8.328 7.790 7.235 6.680 6.125 5.570 8.805 8.250 7.695 7.140 6.585
TC(kW) 8.508 8.858 8.858 9.209 9.527 9.672 10.094 9.527 9.672 10.094 10.342 10.591 10.840 11.089 10.094 10.342 10.591 10.840 11.089
40 SC(kW) 4.930 4.710 6.741 6.521 6.268 5.990 5.376 8.298 8.021 7.407 6.768 6.129 5.491 4.852 8.422 7.783 7.145 6.506 5.868
TC(kW) 8.089 8.418 8.418 8.746 9.056 9.272 9.586 9.056 9.272 9.586 9.806 10.025 10.245 10.465 9.586 9.806 10.025 10.245 10.465
46 SC(kW) 4.513 4.315 6.346 6.147 5.931 5.702 4.993 7.962 7.732 7.023 6.301 5.579 4.857 4.134 8.039 7.316 6.594 5.872 5.150
TC(kW) 7.588 7.889 7.889 8.190 8.491 8.792 8.977 8.491 8.792 8.977 9.162 9.346 9.531 9.716 8.977 9.162 9.346 9.531 9.716
SC(kW) 4.013 3.841 5.871 5.700 5.528 5.356 4.533 7.558 7.386 6.564 5.741 4.918 4.096 3.273 7.579 6.756 5.934 5.111 4.288
R410A Models (Heat Pump) Indoor Unit : M5CC 038 CR Outdoor Unit : M5LC 035 CR Cooling Mode Outdoor DB°C ID DB°C 20
24
28
30
ID WB°C
20 TC(kW) 9.843 10.221 10.221 10.599 10.940 11.269 11.616 10.940 11.269 11.616 11.952 12.289 12.625 12.961 11.616 11.952 12.289 12.625 12.961
15 16 16 17 18 19 20 18 19 20 21 22 23 24 20 21 22 23 24
25 SC(kW) 6.262 5.936 7.966 7.640 7.277 6.912 6.526 9.307 8.942 8.556 8.169 7.781 7.393 7.006 9.572 9.184 8.796 8.409 8.021
TC(kW) 9.344 9.740 9.740 10.136 10.469 10.737 11.109 10.469 10.737 11.109 11.416 11.723 12.030 12.337 11.109 11.416 11.723 12.030 12.337
30 SC(kW) 5.764 5.500 7.531 7.267 6.940 6.604 6.142 8.971 8.635 8.173 7.702 7.230 6.759 6.288 9.188 8.717 8.246 7.775 7.303
TC(kW) 8.926 9.299 9.299 9.672 9.998 10.204 10.601 9.998 10.204 10.601 10.879 11.157 11.435 11.713 10.601 10.879 11.157 11.435 11.713
35 SC(kW) 5.347 5.105 7.136 6.894 6.604 6.297 5.759 8.635 8.328 7.790 7.235 6.680 6.125 5.570 8.805 8.250 7.695 7.140 6.585
TC(kW) 8.508 8.858 8.858 9.209 9.527 9.672 10.094 9.527 9.672 10.094 10.342 10.591 10.840 11.089 10.094 10.342 10.591 10.840 11.089
40 SC(kW) 4.930 4.710 6.741 6.521 6.268 5.990 5.376 8.298 8.021 7.407 6.768 6.129 5.491 4.852 8.422 7.783 7.145 6.506 5.868
TC(kW) 8.089 8.418 8.418 8.746 9.056 9.272 9.586 9.056 9.272 9.586 9.806 10.025 10.245 10.465 9.586 9.806 10.025 10.245 10.465
46 SC(kW) 4.513 4.315 6.346 6.147 5.931 5.702 4.993 7.962 7.732 7.023 6.301 5.579 4.857 4.134 8.039 7.316 6.594 5.872 5.150
TC(kW) 7.588 7.889 7.889 8.190 8.491 8.792 8.977 8.491 8.792 8.977 9.162 9.346 9.531 9.716 8.977 9.162 9.346 9.531 9.716
SC(kW) 4.013 3.841 5.871 5.700 5.528 5.356 4.533 7.558 7.386 6.564 5.741 4.918 4.096 3.273 7.579 6.756 5.934 5.111 4.288
Heating Mode ID DB°C 15 17 19 21 23 25 27
-9 TC(kW) 6.378 6.211 6.044 5.877 5.710 5.542 5.375
-6 SC(kW) 6.378 6.211 6.044 5.877 5.710 5.542 5.375
TC(kW) 7.219 7.497 7.774 7.670 7.184 6.697 6.211
-5 SC(kW) 7.219 7.497 7.774 7.670 7.184 6.697 6.211
TC(kW) 7.499 7.331 7.163 6.994 6.826 6.658 6.489
SC(kW) 7.499 7.331 7.163 6.994 6.826 6.658 6.489
Outdoor WB°C 6 TC(kW) SC(kW) 10.583 10.583 10.570 10.570 10.557 10.557 10.408 10.408 10.123 10.123 9.838 9.838 9.553 9.553
12 TC(kW) 12.264 12.091 11.918 11.744 11.571 11.398 11.224
15 SC(kW) 12.264 12.091 11.918 11.744 11.571 11.398 11.224
TC(kW) 13.105 12.931 12.757 12.583 12.408 12.234 12.060
18 SC(kW) 13.105 12.931 12.757 12.583 12.408 12.234 12.060
TC(kW) 13.946 13.771 13.596 13.421 13.246 13.071 12.896
SC(kW) 13.946 13.771 13.596 13.421 13.246 13.071 12.896
Electrical Data R410A Models (Cooling Only) MODEL
M5CC 038C M5LC 035C
INDOOR UNIT OUTDOOR UNIT
CLASS B
INSULATION GRADE POWER SOURCE INDOOR MOTOR
V/Ph/Hz
RATED INPUT POWER
W
503
RATED RUNNING CURRENT
A
2.27
MOTOR OUTPUT
W
470 4
POLES
CLASS B
INSULATION GRADE POWER SOURCE OUTDOOR MOTOR
V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER
W
220
RATED RUNNING CURRENT
A
1.06
MOTOR OUTPUT
W
145 8
POLES
N/A
INSULATION GRADE V/Ph/Hz
220 - 240 / 1 / 50 / <380 - 415 / 3 / 50>
CAPACITOR - 1Ø / <3Ø>
μF
60 / N/A
RATED INPUT POWER (COOLING) - 1Ø / <3Ø>
W
2564
RATED INPUT POWER (HEATING) - 1Ø / <3Ø>
W
2264
RATED RUNNING CURRENT (COOLING) - 1Ø / <3Ø>
A
11.9
RATED RUNNING CURRENT (HEATING) - 1Ø / <3Ø>
A
10.7
LOCKED ROTOR AMP. - 1Ø / <3Ø>
A
48 / <97>
POWER SOURCE - 1Ø / <3Ø>
COMPRESSOR
220 - 240 / 1 / 50
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
R410A Models (Heat Pump) MODEL
INDOOR UNIT OUTDOOR UNIT
M5CC 038CR M5LC 035CR CLASS B
INSULATION GRADE POWER SOURCE INDOOR MOTOR
V/Ph/Hz
RATED INPUT POWER
W
503
RATED RUNNING CURRENT
A
2.27
MOTOR OUTPUT
W
470 4
POLES
CLASS B
INSULATION GRADE POWER SOURCE OUTDOOR MOTOR
V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER
W
220
RATED RUNNING CURRENT
A
1.06
MOTOR OUTPUT
W
145 8
POLES
N/A
INSULATION GRADE V/Ph/Hz
220 - 240 / 1 / 50 / <380 - 415 / 3 / 50>
CAPACITOR - 1Ø / <3Ø>
μF
60 / N/A
RATED INPUT POWER (COOLING) - 1Ø / <3Ø>
W
2564
RATED INPUT POWER (HEATING) - 1Ø / <3Ø>
W
2264
RATED RUNNING CURRENT (COOLING) - 1Ø / <3Ø>
A
11.9
RATED RUNNING CURRENT (HEATING) - 1Ø / <3Ø>
A
10.7
LOCKED ROTOR AMP. - 1Ø / <3Ø>
A
48 / <97>
POWER SOURCE - 1Ø / <3Ø>
COMPRESSOR
220 - 240 / 1 / 50
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
Exploded View and Parts List Model: M5LC 035 C / CR
No 1 2 3 4 5
6 7 8 9 10 11 12
Description Assy. Base Pan Assy. Flare Valve 3/8" Assy. Flare Valve 5/8" Panel, Partition Compressor M5LC 035C/CR 220-240V/1PH/50Hz 380-415V/3PH/50Hz Service Panel Accumulator Back Panel, Right Top Panel Assy. Coil M5LC 035C/CR Bracket, Fan Motor Side Panel, Left
Part No R50014053238 R50059017536 R50059020805 R50014053277
R50049025547 R50049025336 R01010029898 R02119024262 R01014053233 R01011029900 R50024082878 R01014053232 R01010029899
No
Description 13 Fan Motor 14 Fan Blade 15 Assy. Front Panel 16 Plate, Flare Vlave Parts Not in Diagram Phase Sequencer High Pressure Switch Low Pressure Switch Assy. 4 Way Valve Capacitor, Fan Motor Capacitor, Compressor M5LC 035C/CR Assy. Cap. Tube M5LC 035C M5LC 035CR Contactor
1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
Part No R03039004046 R03013028160 R50014053236 R01013034235 R04089017029 R04104061879 R04109015400 R05019019861 R04029026761 R04029026782 R50024095509 R50024095660 R04039018866