DSXC16 Split System Air Conditioner
P roduct S pecifications
The Goodman® brand DSXC16 Air Conditioner uses the chlorine-free refrigerant R-410A and is part of our new ComfortNet™ family of communicating units. In addition, the DSXC16 features energy efficiencies and operating sound levels that are among the best in the heating and cooling industry. This unit contains the two-stage, high-efficiency Copeland® scroll compressor, which provides improved temperature and humidity control for the consumer who desires superb comfort and quiet operation.
Standard Features • • • • • • • • • • • • • •
R-410A chlorine-free refrigerant Two-Stage Copeland UltraTech scroll compressor High-density foam compressor sound blanket ComfortNet™ Communications System compatible Expanded ComfortAlert diagnostics built in Set-up capable with 2 low-voltage wires to outdoor unit Diagnostic indicator lights and storage of 6 fault codes Color-coded terminal strip for non-communicating set-up High- and low-pressure switches Fully charged for 15’ of tubing length Factory-installed filter dryer Coil and ambient temperature sensors Two-speed, super-quiet condenser fan motor Sweat connection service valves with easy access to gauge ports • AHRI Certified; ETL Listed
16 SEER R-410A
up to
Cabinet Features • • • • • • •
Wire fan discharge grille Steel louver coil guard Baked-on powder paint finish Rust-resistant coated screws Compact footprint Top and side maintenance access Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets 2001 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Cooling Capacity 24,000 - 57,000 BTU/h
Contents
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Compressor Limited Warranty, 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.
SS-DSXC16
Nomenclature......................................................................2 Product Specifications.........................................................3 Expanded Cooling Data........................................................4 AHRI Performance Data.....................................................24 Dimensions........................................................................30 Wiring Diagram..................................................................31 Accessories........................................................................32
www.goodmanmfg.com
3/10 Supersedes 1/10
Product Specifications
Nomenclature D
S
X
C
16
036
1
A
A
1
2
3
4
5,6
7,8,9
10
11
12
Brand D Goodman® Brand
Engineering * Minor Revision
Product Category S Split System
Engineering * Major Revision
Unit Type C Condenser R-22 X Condenser R-410A H Heat Pump R-22 Z Heat Pump R-410A Communication Feature C ComfortNet 4-wire communications ready Efficiency 13 13 SEER 14 14 SEER
Electrical 208/230 V, 1 Phase, 60 Hz 220/240 V, 1 Phase, 50 Hz 208/230 V, 3 Phase, 60 Hz 460 V, 3 Phase, 60 Hz 380/415 V, 3 Phase, 50 Hz
1 2 3 4 5 018 024 030 036 042
16 16 SEER 18 18 SEER
1½ Tons 2 Tons 2½ Tons 3 Tons 3½ Tons
Nominal Capacity 048 4 Tons 060 5 Tons 090 7½ tons 120 10 Tons
* Neither used for order entry or inventory management.
Important EnergyStar Notice: EnergyStar ratings are dependent upon conditions
beyond equipment installation. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet EnergyStar criteria. Ask your contractor for details or visit www.energystar.gov.
2
www.goodmanmfg.com
SS-DSXC16
Product Specifications
Specifications Cooling Capacity Nominal Cooling (BTU/h) Decibels Compressor RLA LRA Condenser Fan Motor Horsepower (RPM) FLA Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) Valve Connection Type Refrigerant Charge Electrical Data Voltage/Hz-Phase Minimum Circuit Ampacity ² Max. Overcurrent Protection ³ Min / Max Volts Power Supply Ship Weight (lbs)
DSXC16 0241A*
DSXC16 0361A*
DSXC16 0481A*
DSXC16 0601A*
DSXC16 0601B*
24,000 71
36,000 70.4/70.9
48,000 74
60,000 75
60,000 75
10.3 52.0
16.7 82.0
21.2 96.0
25.6 118.0
25.6 118.0
1/6 1.1
1/6 0.9
1/6 1.0
1/6 1.0
1/6 1.0
⅜” ¾”
⅜” ⅞”
⅜” 1⅛”
⅜” 1⅛”
⅜” 1⅛”
⅜” ¾” Sweat 97
⅜” ¾” Sweat 107
⅜” ⅞” Sweat 199
⅜” ⅞” Sweat 194
⅜” ⅞” Sweat 197
208/230-60-1 14.0 20 197/253 ½” or ¾” 282
208/230-60-1 21.8 35 197/253 ½” or ¾” 282
208/230-60-1 27.4 40 197/253 ½” or ¾” 282
208/230-60-1 33.0 50 197/253 ½” or ¾” 296
208/230-60-1 33.0 50 197/253 ½” or ¾” 296
¹ Tested and rated in accordance with ARI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL.
SS-DSXC16
www.goodmanmfg.com
3
4
www.goodmanmfg.com
18.3 0.85 21 1.10 4.5 228 122 17.8 0.81 22 1.09 4.4 226 120 16.4 0.78 22 1.08 4.4 223 119
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
525
600
675
59 18.0 0.75 18 1.10 4.5 228 122 17.5 0.71 19 1.09 4.4 226 120 16.1 0.69 19 1.08 4.4 223 119
Airflow MBh S/T ∆T kW 675 Amps HI PR Lo PR MBh S/T ∆T kW 600 Amps HI PR Lo PR MBh S/T ∆T 525 kW Amps HI PR Lo PR
18.8 0.76 20 1.12 4.6 245 125 18.3 0.73 20 1.11 4.5 243 124 16.9 0.70 21 1.10 4.5 240 123
63 18.7 0.63 16 1.12 4.6 245 125 18.1 0.60 17 1.11 4.5 243 124 16.7 0.58 17 1.10 4.5 240 123 20.4 0.58 16 1.16 4.7 248 137 19.8 0.55 17 1.15 4.7 246 136 18.3 0.53 17 1.14 4.6 244 134
67 20.4 0.43 12 1.16 4.7 248 137 19.8 0.41 13 1.15 4.7 246 136 18.3 0.40 13 1.14 4.6 244 134 21.9 0.37 11 1.20 4.9 254 146 21.3 0.35 12 1.19 4.8 251 144 19.6 0.34 12 1.18 4.8 249 143
71 17.9 0.88 21 1.19 4.8 258 125 17.4 0.84 22 1.18 4.8 255 124 16.0 0.81 23 1.17 4.7 252 123
59 17.6 0.78 19 1.19 4.8 258 125 17.1 0.74 19 1.18 4.8 255 124 15.8 0.71 20 1.17 4.7 252 123 18.4 0.79 20 1.21 4.9 277 129 17.9 0.75 21 1.20 4.9 274 128 16.5 0.73 21 1.19 4.8 271 127
63 18.2 0.65 16 1.21 4.9 277 129 17.7 0.62 17 1.20 4.9 274 128 16.3 0.60 17 1.19 4.8 271 127 19.9 0.60 16 1.25 5.1 281 141 19.3 0.57 17 1.24 5.0 278 140 17.9 0.55 17 1.23 5.0 275 138
67 20.0 0.45 12 1.25 5.1 281 141 19.4 0.43 13 1.24 5.0 278 140 17.9 0.41 13 1.23 5.0 275 138
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
21.4 0.38 11 1.30 5.3 287 150 20.8 0.37 12 1.29 5.2 284 149 19.2 0.35 12 1.27 5.2 281 147
71 17.5 0.90 22 1.26 5.2 293 129 16.9 0.86 22 1.25 5.2 290 128 15.6 0.83 23 1.24 5.1 287 127
59 17.2 0.80 19 1.26 5.2 293 129 16.7 0.76 19 1.25 5.2 290 128 15.4 0.73 20 1.24 5.1 287 127 18.0 0.81 20 1.29 5.3 315 133 17.4 0.77 21 1.28 5.3 312 132 16.1 0.74 21 1.27 5.3 309 131
19.4 0.61 16 1.34 5.5 319 146 18.9 0.58 17 1.33 5.5 316 144 17.4 0.56 17 1.31 5.4 313 143
17.0 0.93 22 1.33 5.6 334 133 16.5 0.89 23 1.32 5.5 330 132 15.3 0.86 23 1.31 5.5 327 130
17.5 0.84 20 1.37 5.7 359 137 17.0 0.80 21 1.35 5.7 355 136 15.7 0.77 21 1.34 5.6 352 134
19.0 0.63 16 1.41 5.9 364 150 18.4 0.60 17 1.40 5.8 360 148 17.0 0.58 17 1.39 5.8 357 147
20.4 0.41 11 1.46 6.1 372 159 19.8 0.39 12 1.45 6.1 368 158 18.2 0.37 12 1.44 6.0 364 156
16.2 0.97 21 1.39 5.9 375 135 15.7 0.92 22 1.38 5.9 372 134 14.5 0.89 23 1.37 5.8 368 133
59 15.9 0.85 18 1.39 5.9 375 135 15.4 0.81 19 1.38 5.9 372 134 14.3 0.78 20 1.37 5.8 368 133
Shaded area reflects ACCA (TVA) conditions
20.9 0.39 11 1.38 5.7 326 155 20.3 0.38 12 1.37 5.7 323 154 18.7 0.36 12 1.36 5.6 320 152
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 17.8 19.5 16.7 17.4 19.0 0.66 0.46 0.82 0.69 0.48 16 12 19 16 12 1.29 1.34 1.33 1.37 1.41 5.3 5.5 5.6 5.7 5.9 315 319 334 359 364 133 146 133 137 150 17.3 18.9 16.3 16.8 18.5 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 1.28 1.33 1.32 1.35 1.40 5.3 5.5 5.5 5.7 5.8 312 316 330 355 360 132 144 132 136 148 15.9 17.5 15.0 15.6 17.0 0.61 0.42 0.76 0.63 0.44 17 13 20 17 13 1.27 1.31 1.31 1.34 1.39 5.3 5.4 5.5 5.6 5.8 309 313 327 352 357 131 143 130 134 147 16.7 0.87 20 1.43 6.1 404 140 16.2 0.83 20 1.41 6.0 400 138 14.9 0.80 21 1.40 6.0 396 137
63 16.5 0.71 16 1.43 6.1 404 140 16.0 0.68 17 1.41 6.0 400 138 14.8 0.65 17 1.40 6.0 396 137 18.0 0.66 16 1.48 6.3 409 153 17.5 0.63 17 1.46 6.2 405 151 16.2 0.60 17 1.45 6.2 401 150
67 18.1 0.49 12 1.48 6.3 409 153 17.5 0.47 13 1.46 6.2 405 151 16.2 0.45 13 1.45 6.2 401 150
105ºF
15.0 0.98 20 1.44 6.3 420 139 14.5 0.93 21 1.43 6.2 416 137 13.4 0.90 21 1.42 6.2 412 136
59 14.7 0.86 17 1.44 6.3 420 139 14.3 0.82 18 1.43 6.2 416 137 13.2 0.79 18 1.42 6.2 412 136 15.4 0.87 18 1.48 6.4 452 143 15.0 0.83 19 1.47 6.4 447 142 13.8 0.80 19 1.45 6.3 443 140
63 15.3 0.72 15 1.48 6.4 452 143 14.8 0.68 16 1.47 6.4 447 142 13.7 0.66 16 1.45 6.3 443 140 16.7 0.66 15 1.53 6.6 458 156 16.2 0.63 16 1.52 6.6 454 155 15.0 0.61 16 1.50 6.5 449 153
67 16.7 0.50 11 1.53 6.6 458 156 16.2 0.47 12 1.52 6.6 454 155 15.0 0.46 12 1.50 6.5 449 153 17.9 0.43 10 1.58 6.9 468 166 17.4 0.41 11 1.57 6.8 464 165 16.1 0.39 11 1.56 6.8 459 163
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
19.3 0.42 11 1.53 6.5 418 162 18.8 0.40 12 1.51 6.4 414 161 17.3 0.39 12 1.50 6.4 410 159
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160241A*/ CA*F3636C6C*+TXV/ MBVC1200** Low Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
19.0 0.98 25 1.10 4.5 228 122 18.4 0.93 26 1.09 4.4 226 120 17.0 0.90 26.8 1.08 4.4 223 119
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
525
600
675
59 18.6 0.93 24 1.10 4.5 228 122 18.1 0.89 25 1.09 4.4 226 120 16.7 0.86 25 1.08 4.4 223 119
Airflow MBh S/T ∆T kW 675 Amps HI PR Lo PR MBh S/T ∆T kW 600 Amps HI PR Lo PR MBh S/T ∆T 525 kW Amps HI PR Lo PR
19.3 0.94 25 1.12 4.6 245 125 18.8 0.90 26 1.11 4.5 243 124 17.3 0.87 26 1.10 4.5 240 123
63 19.0 0.88 23 1.12 4.6 245 125 18.5 0.84 24 1.11 4.5 243 124 17.1 0.81 24 1.10 4.5 240 123 20.2 0.85 23 1.16 4.7 248 137 19.6 0.81 24 1.15 4.7 246 136 18.1 0.78 25 1.14 4.6 244 134
67 20.3 0.71 20 1.16 4.7 248 137 19.7 0.68 21 1.15 4.7 246 136 18.2 0.66 21 1.14 4.6 244 134 21.6 0.69 20 1.20 4.9 254 146 21.0 0.66 21 1.19 4.8 251 144 19.3 0.64 22 1.18 4.8 249 143
71 21.7 0.53 16 1.20 4.9 254 146 21.1 0.51 16 1.19 4.8 251 144 19.5 0.49 17 1.18 4.8 249 143 18.5 1.00 25 1.19 4.8 258 125 18.0 0.97 27 1.18 4.8 255 124 16.6 0.93 27 1.17 4.7 252 123
59 18.2 0.97 24 1.19 4.8 258 125 17.7 0.92 25 1.18 4.8 255 124 16.3 0.89 25 1.17 4.7 252 123 18.9 0.98 25 1.21 4.9 277 129 18.3 0.93 26 1.20 4.9 274 128 16.9 0.90 27 1.19 4.8 271 127
63 18.6 0.91 23 1.21 4.9 277 129 18.1 0.87 24 1.20 4.9 274 128 16.7 0.83 24 1.19 4.8 271 127 19.8 0.88 24 1.25 5.1 281 141 19.2 0.84 25 1.24 5.0 278 140 17.7 0.81 25 1.23 5.0 275 138
67 19.9 0.74 20 1.25 5.1 281 141 19.3 0.70 21 1.24 5.0 278 140 17.8 0.68 21 1.23 5.0 275 138
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
21.1 0.72 21 1.30 5.3 287 150 20.5 0.68 21 1.29 5.2 284 149 18.9 0.66 22 1.27 5.2 281 147
71 21.2 0.55 16 1.30 5.3 287 150 20.6 0.53 17 1.29 5.2 284 149 19.0 0.51 17 1.27 5.2 281 147 18.1 1.00 25 1.26 5.2 293 129 17.5 0.99 27 1.25 5.2 290 128 16.2 0.96 27 1.24 5.1 287 127
59 17.8 1.00 24 1.26 5.2 293 129 17.2 0.95 25 1.25 5.2 290 128 15.9 0.91 25 1.24 5.1 287 127 18.4 1.00 25 1.29 5.3 315 133 17.9 0.96 26 1.28 5.3 312 132 16.5 0.92 27 1.27 5.3 309 131
19.3 0.91 24 1.34 5.5 319 146 18.7 0.86 25 1.33 5.5 316 144 17.3 0.83 25 1.31 5.4 313 143
17.6 1.00 24 1.33 5.6 334 133 17.1 1.00 26 1.32 5.5 330 132 15.8 0.99 27 1.31 5.5 327 130
18.0 1.00 24 1.37 5.7 359 137 17.4 0.99 26 1.35 5.7 355 136 16.1 0.95 27 1.34 5.6 352 134
18.8 0.93 24 1.41 5.9 364 150 18.3 0.89 25 1.40 5.8 360 148 16.9 0.86 25 1.39 5.8 357 147
20.1 0.76 21 1.46 6.1 372 159 19.5 0.72 22 1.45 6.1 368 158 18.0 0.70 22 1.44 6.0 364 156
71 20.2 0.58 16 1.46 6.1 372 159 19.6 0.56 17 1.45 6.1 368 158 18.1 0.54 17 1.44 6.0 364 156 16.8 1.00 23 1.39 5.9 375 135 16.3 1.00 25 1.38 5.9 372 134 15.0 1.00 26 1.37 5.8 368 133
59 16.5 1.00 22 1.39 5.9 375 135 16.0 1.00 24 1.38 5.9 372 134 14.8 0.98 25 1.37 5.8 368 133
Shaded area reflects AHRI (TVA) conditions
20.6 0.73 21 1.38 5.7 326 155 20.0 0.70 21 1.37 5.7 323 154 18.4 0.68 22 1.36 5.6 320 152
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 18.1 19.4 20.7 17.3 17.7 18.9 0.93 0.76 0.57 1.00 0.96 0.78 23 20 16 24 23 20 1.29 1.34 1.38 1.33 1.37 1.41 5.3 5.5 5.7 5.6 5.7 5.9 315 319 326 334 359 364 133 146 155 133 137 150 17.6 18.8 20.1 16.8 17.2 18.4 0.89 0.72 0.54 0.98 0.92 0.75 24 21 17 25 24 21 1.28 1.33 1.37 1.32 1.35 1.40 5.3 5.5 5.7 5.5 5.7 5.8 312 316 323 330 355 360 132 144 154 132 136 148 16.3 17.4 18.6 15.5 15.9 17.0 0.86 0.70 0.52 0.94 0.88 0.72 24 21 17 26 25 21 1.27 1.31 1.36 1.31 1.34 1.39 5.3 5.4 5.6 5.5 5.6 5.8 309 313 320 327 352 357 131 143 152 130 134 147 17.1 1.00 23 1.43 6.1 404 140 16.6 1.00 25 1.41 6.0 400 138 15.3 0.99 26 1.40 6.0 396 137
63 16.8 1.00 23 1.43 6.1 404 140 16.3 0.95 24 1.41 6.0 400 138 15.1 0.92 24 1.40 6.0 396 137 17.9 0.97 24 1.48 6.3 409 153 17.4 0.93 25 1.46 6.2 405 151 16.0 0.89 25 1.45 6.2 401 150
67 18.0 0.81 20 1.48 6.3 409 153 17.4 0.77 21 1.46 6.2 405 151 16.1 0.75 21 1.45 6.2 401 150
105ºF
15.5 1.00 21 1.44 6.3 420 139 15.1 1.00 23 1.43 6.2 416 137 13.9 1.00 24 1.42 6.2 412 136
59 15.2 1.00 21 1.44 6.3 420 139 14.8 1.00 23 1.43 6.2 416 137 13.7 0.99 24 1.42 6.2 412 136 15.8 1.00 22 1.48 6.4 452 143 15.4 1.00 24 1.47 6.4 447 142 14.2 1.00 25 1.45 6.3 443 140
63 15.6 1.00 21 1.48 6.4 452 143 15.1 0.96 22 1.47 6.4 447 142 14.0 0.92 23 1.45 6.3 443 140
71 17.8 0.61 15 1.58 6.9 468 166 17.3 0.58 15 1.57 6.8 464 165 15.9 0.56 16 1.56 6.8 459 163 16.6 17.7 0.98 0.79 22 19 1.53 1.58 6.6 6.9 458 468 156 166 16.1 17.2 0.93 0.76 23 20 1.52 1.57 6.6 6.8 454 464 155 165 14.8 15.8 0.90 0.73 23 20 1.50 1.56 6.5 6.8 449 459 153 163
67 16.6 0.82 19 1.53 6.6 458 156 16.2 0.78 19 1.52 6.6 454 155 14.9 0.75 20 1.50 6.5 449 153
kW = Total system power Amps = outdoor unit amps (comp.+fan)
19.1 0.79 20 1.53 6.5 418 162 18.5 0.75 21 1.51 6.4 414 161 17.1 0.72 22 1.50 6.4 410 159
71 19.2 0.61 16 1.53 6.5 418 162 18.7 0.58 17 1.51 6.4 414 161 17.2 0.56 17 1.50 6.4 410 159
115ºF
Product Specifications
Expanded Cooling Data — DSXC160241A*/ CA*F3636C6C*+TXV/ MBVC1200** Low Stage (cont.)
5
6
www.goodmanmfg.com
23.9 0.86 21 1.50 5.9 237 122 23.2 0.82 22 1.49 5.9 234 120 21.4 0.79 22 1.48 5.8 232 119
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
700
800
900
59 23.5 0.76 18 1.50 5.9 237 122 22.8 0.72 19 1.49 5.9 234 120 21.1 0.70 19 1.48 5.8 232 119
Airflow MBh S/T ∆T kW 900 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 700 kW Amps HI PR Lo PR
24.6 0.77 19 1.53 6.0 255 125 23.9 0.73 20 1.52 6.0 252 124 22.1 0.71 21 1.51 5.9 249 123
63 24.4 0.63 16 1.53 6.0 255 125 23.7 0.60 16 1.52 6.0 252 124 21.8 0.58 17 1.51 5.9 249 123 26.7 0.58 16 1.58 6.2 258 137 25.9 0.56 17 1.57 6.2 256 136 23.9 0.54 17 1.56 6.1 253 134
67 26.7 0.44 12 1.58 6.2 258 137 25.9 0.42 12 1.57 6.2 256 136 23.9 0.40 13 1.56 6.1 253 134 28.6 0.37 11 1.63 6.5 264 146 27.8 0.36 11 1.62 6.4 261 144 25.6 0.34 12 1.61 6.3 259 143
71 23.4 0.89 21 1.62 6.4 268 125 22.7 0.85 22 1.61 6.3 265 124 20.9 0.82 23 1.59 6.3 262 123
59 23.0 0.78 18 1.62 6.4 268 125 22.3 0.75 19 1.61 6.3 265 124 20.6 0.72 20 1.59 6.3 262 123 24.1 0.80 20 1.65 6.5 288 129 23.4 0.76 20 1.64 6.5 285 128 21.6 0.73 21 1.63 6.4 282 127
63 23.8 0.66 16 1.65 6.5 288 129 23.1 0.63 17 1.64 6.5 285 128 21.3 0.60 17 1.63 6.4 282 127 26.0 0.60 16 1.71 6.7 292 141 25.3 0.58 17 1.69 6.7 289 140 23.3 0.56 17 1.68 6.6 286 138
67 26.1 0.45 12 1.71 6.7 292 141 25.3 0.43 13 1.69 6.7 289 140 23.4 0.42 13 1.68 6.6 286 138
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
27.9 0.39 11 1.77 7.0 298 150 27.1 0.37 12 1.75 6.9 295 149 25.0 0.36 12 1.74 6.8 292 147
71 22.8 0.91 21 1.72 6.9 304 129 22.1 0.87 22 1.71 6.8 301 128 20.4 0.84 23 1.69 6.8 298 127
59 22.4 0.80 18 1.72 6.9 304 129 21.8 0.77 19 1.71 6.8 301 128 20.1 0.74 20 1.69 6.8 298 127 23.5 0.82 20 1.76 7.1 327 134 22.8 0.78 20 1.75 7.0 324 132 21.0 0.75 21 1.73 6.9 321 131
25.4 0.62 16 1.82 7.3 332 146 24.7 0.59 17 1.80 7.2 329 144 22.8 0.57 17 1.79 7.2 325 143
22.2 0.94 21 1.81 7.4 347 133 21.6 0.90 22 1.80 7.3 343 132 19.9 0.87 23 1.78 7.2 340 130
22.9 0.84 20 1.86 7.5 373 137 22.2 0.81 21 1.84 7.5 369 136 20.5 0.78 21 1.82 7.4 365 134
24.8 0.64 16 1.92 7.8 378 150 24.1 0.61 17 1.90 7.7 374 148 22.2 0.59 17 1.89 7.6 370 147
26.6 0.41 11 1.98 8.1 386 159 25.8 0.39 12 1.97 8.0 382 158 23.8 0.38 12 1.95 7.9 379 156
21.1 0.98 21 1.89 7.8 390 136 20.5 0.93 22 1.88 7.8 386 134 18.9 0.90 22 1.86 7.7 382 133
59 20.8 0.86 18 1.89 7.8 390 136 20.2 0.82 19 1.88 7.8 386 134 18.6 0.79 19 1.86 7.7 382 133
Shaded area reflects ACCA (TVA) conditions
27.3 0.40 11 1.88 7.6 339 155 26.5 0.38 12 1.87 7.5 336 154 24.4 0.37 12 1.85 7.4 332 152
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 23.2 25.5 21.9 22.7 24.8 0.67 0.47 0.83 0.69 0.48 16 12 19 16 12 1.76 1.82 1.81 1.86 1.92 7.1 7.3 7.4 7.5 7.8 327 332 347 373 378 134 146 133 137 150 22.6 24.7 21.2 22.0 24.1 0.64 0.44 0.79 0.66 0.46 17 13 19 17 13 1.75 1.80 1.80 1.84 1.90 7.0 7.2 7.3 7.5 7.7 324 329 343 369 374 132 144 132 136 148 20.8 22.8 19.6 20.3 22.3 0.62 0.43 0.76 0.64 0.44 17 13 20 17 13 1.73 1.79 1.78 1.82 1.89 6.9 7.2 7.2 7.4 7.6 321 325 340 365 370 131 143 130 134 147 21.8 0.88 19 1.94 8.0 419 140 21.1 0.84 20 1.92 7.9 415 138 19.5 0.81 21 1.90 7.9 411 137
63 21.5 0.72 16 1.94 8.0 419 140 20.9 0.69 17 1.92 7.9 415 138 19.3 0.66 17 1.90 7.9 411 137 23.6 0.66 16 2.00 8.3 425 153 22.9 0.63 17 1.98 8.2 421 151 21.1 0.61 17 1.97 8.1 417 150
67 23.6 0.50 12 2.00 8.3 425 153 22.9 0.48 13 1.98 8.2 421 151 21.1 0.46 13 1.97 8.1 417 150
105ºF
19.6 0.99 20 1.96 8.3 437 139 19.0 0.94 21 1.94 8.2 432 138 17.5 0.91 21 1.93 8.1 428 136
59 19.3 0.87 17 1.96 8.3 437 139 18.7 0.83 18 1.94 8.2 432 138 17.3 0.80 18 1.93 8.1 428 136 20.2 0.88 18 2.01 8.5 470 143 19.6 0.84 19 1.99 8.4 465 142 18.1 0.81 19 1.97 8.3 460 140
63 20.0 0.73 15 2.01 8.5 470 143 19.4 0.69 15 1.99 8.4 465 142 17.9 0.67 16 1.97 8.3 460 140 21.8 0.67 15 2.07 8.7 476 156 21.2 0.64 16 2.06 8.7 471 155 19.6 0.62 16 2.04 8.6 467 153
67 21.9 0.50 11 2.07 8.7 476 156 21.2 0.48 12 2.06 8.7 471 155 19.6 0.46 12 2.04 8.6 467 153 23.4 0.43 10 2.15 9.1 487 167 22.7 0.41 11 2.13 9.0 482 165 21.0 0.40 11 2.11 8.9 477 163
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
25.3 0.43 11 2.07 8.6 435 163 24.5 0.41 11 2.05 8.5 430 161 22.7 0.39 12 2.04 8.4 426 159
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160241A*/ CA*F3636C6C*+TXV/ MBVC1200** High Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
24.8 0.99 25 1.50 5.9 237 122 24.0 0.94 26 1.49 5.9 234 120 22.2 0.91 26.5 1.48 5.8 232 119
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
700
800
900
59 24.3 0.94 23 1.50 5.9 237 122 23.6 0.90 24 1.49 5.9 234 120 21.8 0.87 25 1.48 5.8 232 119
Airflow MBh S/T ∆T kW 900 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 700 kW Amps HI PR Lo PR
25.2 0.96 25 1.53 6.0 255 125 24.5 0.91 26 1.52 6.0 252 124 22.6 0.88 26 1.51 5.9 249 123
63 24.9 0.89 22 1.53 6.0 255 125 24.1 0.84 23 1.52 6.0 252 124 22.3 0.81 24 1.51 5.9 249 123 26.4 0.86 23 1.58 6.2 258 137 25.7 0.82 24 1.57 6.2 256 136 23.7 0.79 25 1.56 6.1 253 134
67 26.6 0.72 20 1.58 6.2 258 137 25.8 0.69 20 1.57 6.2 256 136 23.8 0.66 21 1.56 6.1 253 134 28.2 0.70 20 1.63 6.5 264 146 27.4 0.67 21 1.62 6.4 261 144 25.3 0.64 21 1.61 6.3 259 143
71 28.4 0.54 16 1.63 6.5 264 146 27.6 0.51 16 1.62 6.4 261 144 25.5 0.50 17 1.61 6.3 259 143 24.2 1.00 25 1.62 6.4 268 125 23.5 0.98 26 1.61 6.3 265 124 21.7 0.94 27 1.59 6.3 262 123
59 23.8 1.00 24 1.62 6.4 268 125 23.1 0.93 25 1.61 6.3 265 124 21.3 0.90 25 1.59 6.3 262 123 24.7 0.99 25 1.65 6.5 288 129 23.9 0.94 26 1.64 6.5 285 128 22.1 0.91 26 1.63 6.4 282 127
63 24.3 0.92 23 1.65 6.5 288 129 23.6 0.88 24 1.64 6.5 285 128 21.8 0.84 24 1.63 6.4 282 127 25.8 0.89 24 1.71 6.7 292 141 25.1 0.85 25 1.69 6.7 289 140 23.1 0.82 25 1.68 6.6 286 138
67 26.0 0.75 20 1.71 6.7 292 141 25.2 0.71 21 1.69 6.7 289 140 23.3 0.69 21 1.68 6.6 286 138
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
27.6 0.72 20 1.77 7.0 298 150 26.8 0.69 21 1.75 6.9 295 149 24.7 0.67 22 1.74 6.8 292 147
71 27.7 0.56 16 1.77 7.0 298 150 26.9 0.53 16 1.75 6.9 295 149 24.9 0.51 17 1.74 6.8 292 147 23.6 1.00 24 1.72 6.9 304 129 22.9 1.00 26 1.71 6.8 301 128 21.2 0.97 27 1.69 6.8 298 127
59 23.2 1.00 24 1.72 6.9 304 129 22.5 0.96 25 1.71 6.8 301 128 20.8 0.92 25 1.69 6.8 298 127 24.1 1.00 25 1.76 7.1 327 134 23.4 0.97 26 1.75 7.0 324 132 21.6 0.93 26 1.73 6.9 321 131
25.2 0.92 24 1.82 7.3 332 146 24.5 0.87 25 1.80 7.2 329 144 22.6 0.84 25 1.79 7.2 325 143
23.0 1.00 24 1.81 7.4 347 133 22.4 1.00 26 1.80 7.3 343 132 20.6 1.00 27 1.78 7.2 340 130
23.5 1.00 24 1.86 7.5 373 137 22.8 1.00 26 1.84 7.5 369 136 21.0 0.96 27 1.82 7.4 365 134
24.6 0.95 24 1.92 7.8 378 150 23.9 0.90 25 1.90 7.7 374 148 22.0 0.87 25 1.89 7.6 370 147
26.2 0.77 21 1.98 8.1 386 159 25.5 0.73 21 1.97 8.0 382 158 23.5 0.71 22 1.95 7.9 379 156
71 26.4 0.59 16 1.98 8.1 386 159 25.7 0.56 17 1.97 8.0 382 158 23.7 0.54 17 1.95 7.9 379 156 21.9 1.00 22 1.89 7.8 390 136 21.2 1.00 24 1.88 7.8 386 134 19.6 1.00 26 1.86 7.7 382 133
59 21.5 1.00 22 1.89 7.8 390 136 20.9 1.00 24 1.88 7.8 386 134 19.3 0.99 25 1.86 7.7 382 133
Shaded area reflects AHRI (TVA) conditions
26.9 0.74 20 1.88 7.6 339 155 26.1 0.71 21 1.87 7.5 336 154 24.1 0.68 22 1.85 7.4 332 152
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.7 25.3 27.1 22.6 23.1 24.7 0.94 0.77 0.57 1.00 1.00 0.79 23 20 16 23 24 20 1.76 1.82 1.88 1.81 1.86 1.92 7.1 7.3 7.6 7.4 7.5 7.8 327 332 339 347 373 378 134 146 155 133 137 150 23.0 24.6 26.3 22.0 22.5 24.0 0.90 0.73 0.55 0.99 0.93 0.75 24 21 16 25 24 21 1.75 1.80 1.87 1.80 1.84 1.90 7.0 7.2 7.5 7.3 7.5 7.7 324 329 336 343 369 374 132 144 154 132 136 148 21.3 22.7 24.3 20.3 20.7 22.2 0.87 0.70 0.53 0.95 0.89 0.73 24 21 17 25 24 21 1.73 1.79 1.85 1.78 1.82 1.89 6.9 7.2 7.4 7.2 7.4 7.6 321 325 332 340 365 370 131 143 152 130 134 147 22.3 1.00 23 1.94 8.0 419 140 21.7 1.00 25 1.92 7.9 415 138 20.0 1.00 26 1.90 7.9 411 137
63 22.0 1.00 22 1.94 8.0 419 140 21.3 0.96 24 1.92 7.9 415 138 19.7 0.93 24 1.90 7.9 411 137 23.4 0.98 23 2.00 8.3 425 153 22.7 0.94 24 1.98 8.2 421 151 20.9 0.90 25 1.97 8.1 417 150
67 23.5 0.82 20 2.00 8.3 425 153 22.8 0.78 21 1.98 8.2 421 151 21.0 0.75 21 1.97 8.1 417 150
105ºF
20.3 1.00 21 1.96 8.3 437 139 19.7 1.00 23 1.94 8.2 432 138 18.2 1.00 24 1.93 8.1 428 136
59 19.9 1.00 20 1.96 8.3 437 139 19.3 1.00 22 1.94 8.2 432 138 17.9 1.00 23 1.93 8.1 428 136 20.7 1.00 21 2.01 8.5 470 143 20.1 1.00 23 1.99 8.4 465 142 18.5 1.00 24 1.97 8.3 460 140
63 20.4 1.00 21 2.01 8.5 470 143 19.8 0.97 22 1.99 8.4 465 142 18.2 0.93 22 1.97 8.3 460 140
71 23.3 0.62 15 2.15 9.1 487 167 22.6 0.59 15 2.13 9.0 482 165 20.8 0.57 16 2.11 8.9 477 163 21.6 23.1 0.99 0.80 22 19 2.07 2.15 8.7 9.1 476 487 156 167 21.0 22.4 0.94 0.77 23 20 2.06 2.13 8.7 9.0 471 482 155 165 19.4 20.7 0.91 0.74 23 20 2.04 2.11 8.6 8.9 467 477 153 163
67 21.8 0.83 18 2.07 8.7 476 156 21.1 0.79 19 2.06 8.7 471 155 19.5 0.76 19 2.04 8.6 467 153
kW = Total system power Amps = outdoor unit amps (comp.+fan)
24.9 0.80 20 2.07 8.6 435 163 24.2 0.76 21 2.05 8.5 430 161 22.3 0.73 21 2.04 8.4 426 159
71 25.1 0.61 16 2.07 8.6 435 163 24.4 0.58 16 2.05 8.5 430 161 22.5 0.56 17 2.04 8.4 426 159
115ºF
Product Specifications
Expanded Cooling Data — DSXC160241A*/ CA*F3636C6C*+TXV/ MBVC1200** High Stage (cont.)
7
8
www.goodmanmfg.com
25.3 0.81 21 1.50 5.8 220 119 24.6 0.78 22 1.49 5.8 218 118 22.7 0.75 22 1.47 5.7 216 117
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
696
800
904
59 24.9 0.72 18 1.50 5.8 220 119 24.2 0.68 19 1.49 5.8 218 118 22.3 0.66 19 1.47 5.7 216 117
Airflow MBh S/T ∆T kW 904 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 696 kW Amps HI PR Lo PR
26.1 0.73 19 1.53 6.0 237 123 25.3 0.69 20 1.52 5.9 234 122 23.4 0.67 21 1.51 5.9 232 121
63 25.8 0.60 16 1.53 6.0 237 123 25.1 0.57 16 1.52 5.9 234 122 23.1 0.55 17 1.51 5.9 232 121 28.2 0.55 16 1.58 6.2 240 134 27.4 0.53 17 1.57 6.1 238 133 25.3 0.51 17 1.55 6.0 235 132
67 28.3 0.41 12 1.58 6.2 240 134 27.5 0.40 12 1.57 6.1 238 133 25.3 0.38 13 1.55 6.0 235 132 30.3 0.35 11 1.63 6.4 245 143 29.4 0.34 11 1.62 6.3 243 142 27.2 0.33 12 1.60 6.3 241 140
71 24.7 0.84 21 1.61 6.3 249 123 24.0 0.80 22 1.60 6.2 246 122 22.2 0.78 23 1.59 6.2 244 120
59 24.3 0.74 18 1.61 6.3 249 123 23.6 0.71 19 1.60 6.2 246 122 21.8 0.68 20 1.59 6.2 244 120 25.5 0.75 20 1.65 6.4 268 127 24.7 0.72 20 1.64 6.4 265 125 22.8 0.69 21 1.62 6.3 262 124
63 25.2 0.62 16 1.65 6.4 268 127 24.5 0.59 17 1.64 6.4 265 125 22.6 0.57 17 1.62 6.3 262 124 27.6 0.57 16 1.70 6.6 271 138 26.8 0.54 17 1.69 6.6 269 137 24.7 0.53 17 1.67 6.5 266 136
67 27.6 0.43 12 1.70 6.6 271 138 26.8 0.41 13 1.69 6.6 269 137 24.8 0.39 13 1.67 6.5 266 136
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
29.6 0.37 11 1.76 6.9 277 147 28.7 0.35 12 1.74 6.8 275 146 26.5 0.34 12 1.73 6.8 272 144
71 24.2 0.87 21 1.72 6.8 283 127 23.5 0.83 22 1.70 6.7 280 126 21.6 0.80 23 1.69 6.7 277 125
59 23.8 0.76 18 1.72 6.8 283 127 23.1 0.73 19 1.70 6.7 280 126 21.3 0.70 20 1.69 6.7 277 125 24.9 0.77 20 1.75 7.0 304 131 24.1 0.74 20 1.74 6.9 301 130 22.3 0.71 21 1.73 6.8 298 128
26.9 0.59 16 1.81 7.2 309 143 26.1 0.56 17 1.80 7.1 306 142 24.1 0.54 17 1.78 7.1 303 140
23.6 0.89 21 1.81 7.3 322 130 22.9 0.85 22 1.79 7.2 319 129 21.1 0.82 23 1.78 7.1 316 128
24.3 0.80 20 1.85 7.4 347 135 23.6 0.76 21 1.83 7.4 343 133 21.7 0.73 21 1.82 7.3 340 132
26.3 0.60 16 1.91 7.7 352 147 25.5 0.58 17 1.89 7.6 348 145 23.5 0.56 17 1.88 7.5 345 144
28.2 0.39 11 1.97 7.9 359 156 27.4 0.37 12 1.96 7.9 356 155 25.3 0.36 12 1.94 7.8 352 153
22.4 0.93 21 1.88 7.7 348 133 21.7 0.88 22 1.87 7.6 345 132 20.1 0.85 23 1.85 7.6 341 130
59 22.0 0.82 18 1.88 7.7 348 133 21.4 0.78 19 1.87 7.6 345 132 19.7 0.75 20 1.85 7.6 341 130
Shaded area reflects ACCA (TVA) conditions
28.9 0.38 11 1.87 7.4 315 152 28.0 0.36 12 1.86 7.4 312 151 25.9 0.35 12 1.84 7.3 309 149
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 24.6 27.0 23.2 24.0 26.3 0.64 0.44 0.79 0.66 0.45 16 12 19 16 12 1.75 1.81 1.81 1.85 1.91 7.0 7.2 7.3 7.4 7.7 304 309 322 347 352 131 143 130 135 147 23.9 26.2 22.5 23.3 25.5 0.61 0.42 0.75 0.63 0.43 17 13 19 17 13 1.74 1.80 1.79 1.83 1.89 6.9 7.1 7.2 7.4 7.6 301 306 319 343 348 130 142 129 133 145 22.1 24.2 20.8 21.5 23.6 0.58 0.40 0.72 0.60 0.42 17 13 20 17 13 1.73 1.78 1.78 1.82 1.88 6.8 7.1 7.1 7.3 7.5 298 303 316 340 345 128 140 128 132 144 23.0 0.83 19 1.93 7.9 374 137 22.4 0.79 20 1.91 7.8 371 136 20.7 0.76 21 1.89 7.8 367 134
63 22.8 0.68 16 1.93 7.9 374 137 22.2 0.65 17 1.91 7.8 371 136 20.4 0.63 17 1.89 7.8 367 134 24.9 0.63 16 1.99 8.1 380 150 24.2 0.60 17 1.97 8.1 376 148 22.4 0.58 17 1.96 8.0 372 147
67 25.0 0.47 12 1.99 8.1 380 150 24.3 0.45 13 1.97 8.1 376 148 22.4 0.43 13 1.96 8.0 372 147
105ºF
20.7 0.93 20 1.95 8.2 413 136 20.1 0.89 21 1.93 8.1 409 135 18.6 0.86 21 1.92 8.0 404 134
59 20.4 0.82 17 1.95 8.2 413 136 19.8 0.78 18 1.93 8.1 409 135 18.3 0.76 18 1.92 8.0 404 134 21.4 0.84 18 2.00 8.3 444 141 20.7 0.80 19 1.98 8.3 439 139 19.1 0.77 19 1.96 8.2 435 138
63 21.1 0.69 15 2.00 8.3 444 141 20.5 0.65 15 1.98 8.3 439 139 18.9 0.63 16 1.96 8.2 435 138 23.1 0.63 15 2.06 8.6 450 153 22.4 0.60 16 2.04 8.5 446 152 20.7 0.58 16 2.03 8.5 441 150
67 23.2 0.48 11 2.06 8.6 450 153 22.5 0.45 12 2.04 8.5 446 152 20.8 0.44 12 2.03 8.5 441 150 24.8 0.41 10 2.13 8.9 460 163 24.1 0.39 11 2.11 8.9 455 162 22.2 0.37 11 2.10 8.8 451 160
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
26.8 0.40 11 2.06 8.4 388 160 26.0 0.38 12 2.04 8.4 384 158 24.0 0.37 12 2.02 8.3 380 156
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160361A* / CA*F3743*6A* +TXV / MBVC1600** Low Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
26.2 0.94 25 1.50 5.8 220 119 25.5 0.89 26 1.49 5.8 218 118 23.5 0.86 26.7 1.47 5.7 216 117
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
696
800
904
59 25.8 0.89 23 1.50 5.8 220 119 25.0 0.85 24 1.49 5.8 218 118 23.1 0.82 25 1.47 5.7 216 117
Airflow MBh S/T ∆T kW 904 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 696 kW Amps HI PR Lo PR
26.7 0.90 25 1.53 6.0 237 123 26.0 0.86 26 1.52 5.9 234 122 24.0 0.83 26 1.51 5.9 232 121
63 26.3 0.84 22 1.53 6.0 237 123 25.6 0.80 23 1.52 5.9 234 122 23.6 0.77 24 1.51 5.9 232 121 28.0 0.82 23 1.58 6.2 240 134 27.2 0.78 24 1.57 6.1 238 133 25.1 0.75 25 1.55 6.0 235 132
67 28.1 0.68 20 1.58 6.2 240 134 27.3 0.65 20 1.57 6.1 238 133 25.2 0.63 21 1.55 6.0 235 132 29.9 0.66 20 1.63 6.4 245 143 29.0 0.63 21 1.62 6.3 243 142 26.8 0.61 22 1.60 6.3 241 140
71 30.1 0.51 16 1.63 6.4 245 143 29.2 0.49 16 1.62 6.3 243 142 27.0 0.47 17 1.60 6.3 241 140 25.6 0.97 25 1.61 6.3 249 123 24.9 0.93 26 1.60 6.2 246 122 23.0 0.89 27 1.59 6.2 244 120
59 25.2 0.93 24 1.61 6.3 249 123 24.4 0.88 25 1.60 6.2 246 122 22.6 0.85 25 1.59 6.2 244 120 26.1 0.94 25 1.65 6.4 268 127 25.4 0.89 26 1.64 6.4 265 125 23.4 0.86 27 1.62 6.3 262 124
63 25.7 0.87 23 1.65 6.4 268 127 25.0 0.83 24 1.64 6.4 265 125 23.1 0.80 24 1.62 6.3 262 124 27.4 0.84 24 1.70 6.6 271 138 26.6 0.81 25 1.69 6.6 269 137 24.5 0.78 25 1.67 6.5 266 136
67 27.5 0.71 20 1.70 6.6 271 138 26.7 0.67 21 1.69 6.6 269 137 24.6 0.65 21 1.67 6.5 266 136
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
29.2 0.69 20 1.76 6.9 277 147 28.3 0.65 21 1.74 6.8 275 146 26.2 0.63 22 1.73 6.8 272 144
71 29.4 0.53 16 1.76 6.9 277 147 28.5 0.50 17 1.74 6.8 275 146 26.3 0.49 17 1.73 6.8 272 144 25.0 0.99 25 1.72 6.8 283 127 24.3 0.95 26 1.70 6.7 280 126 22.4 0.91 27 1.69 6.7 277 125
59 24.6 0.95 24 1.72 6.8 283 127 23.9 0.90 25 1.70 6.7 280 126 22.0 0.87 25 1.69 6.7 277 125 25.5 0.96 25 1.75 7.0 304 131 24.8 0.92 26 1.74 6.9 301 130 22.8 0.88 27 1.73 6.8 298 128
26.7 0.87 24 1.81 7.2 309 143 25.9 0.83 25 1.80 7.1 306 142 23.9 0.80 25 1.78 7.1 303 140
24.4 1.00 25 1.81 7.3 322 130 23.7 0.98 27 1.79 7.2 319 129 21.9 0.94 27 1.78 7.1 316 128
24.9 0.99 25 1.85 7.4 347 135 24.2 0.94 26 1.83 7.4 343 133 22.3 0.91 27 1.82 7.3 340 132
26.1 0.89 24 1.91 7.7 352 147 25.3 0.85 25 1.89 7.6 348 145 23.3 0.82 25 1.88 7.5 345 144
27.8 0.73 21 1.97 7.9 359 156 27.0 0.69 21 1.96 7.9 356 155 24.9 0.67 22 1.94 7.8 352 153
71 28.0 0.56 16 1.97 7.9 359 156 27.2 0.53 17 1.96 7.9 356 155 25.1 0.51 17 1.94 7.8 352 153 23.2 1.00 24 1.88 7.7 348 133 22.5 1.00 26 1.87 7.6 345 132 20.8 0.98 27 1.85 7.6 341 130
59 22.8 1.00 23 1.88 7.7 348 133 22.1 0.97 25 1.87 7.6 345 132 20.4 0.93 25 1.85 7.6 341 130
Shaded area reflects AHRI (TVA) conditions
28.5 0.70 20 1.87 7.4 315 152 27.7 0.67 21 1.86 7.4 312 151 25.5 0.65 22 1.84 7.3 309 149
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 25.1 26.8 28.7 24.0 24.5 26.2 0.89 0.72 0.54 1.00 0.92 0.75 23 20 16 24 23 20 1.75 1.81 1.87 1.81 1.85 1.91 7.0 7.2 7.4 7.3 7.4 7.7 304 309 315 322 347 352 131 143 152 130 135 147 24.4 26.1 27.9 23.3 23.8 25.4 0.85 0.69 0.52 0.93 0.88 0.71 24 21 17 25 24 21 1.74 1.80 1.86 1.79 1.83 1.89 6.9 7.1 7.4 7.2 7.4 7.6 301 306 312 319 343 348 130 142 151 129 133 145 22.5 24.1 25.7 21.5 22.0 23.5 0.82 0.67 0.50 0.90 0.84 0.69 24 21 17 26 25 21 1.73 1.78 1.84 1.78 1.82 1.88 6.8 7.1 7.3 7.1 7.3 7.5 298 303 309 316 340 345 128 140 149 128 132 144 23.6 1.00 24 1.93 7.9 374 137 22.9 0.98 26 1.91 7.8 371 136 21.2 0.95 26 1.89 7.8 367 134
63 23.3 0.95 23 1.93 7.9 374 137 22.6 0.91 24 1.91 7.8 371 136 20.9 0.88 24 1.89 7.8 367 134 24.8 0.93 23 1.99 8.1 380 150 24.0 0.89 24 1.97 8.1 376 148 22.2 0.85 25 1.96 8.0 372 147
67 24.9 0.78 20 1.99 8.1 380 150 24.1 0.74 21 1.97 8.1 376 148 22.3 0.71 21 1.96 8.0 372 147
105ºF
21.5 1.00 22 1.95 8.2 413 136 20.8 1.00 24 1.93 8.1 409 135 19.2 0.99 25 1.92 8.0 404 134
59 21.1 1.00 21 1.95 8.2 413 136 20.5 0.98 23 1.93 8.1 409 135 18.9 0.94 24 1.92 8.0 404 134 21.9 1.00 22 2.00 8.3 444 141 21.3 0.99 24 1.98 8.3 439 139 19.6 0.95 25 1.96 8.2 435 138
63 21.6 0.96 21 2.00 8.3 444 141 20.9 0.92 22 1.98 8.3 439 139 19.3 0.88 23 1.96 8.2 435 138
71 24.6 0.58 15 2.13 8.9 460 163 23.9 0.56 15 2.11 8.9 455 162 22.1 0.54 16 2.10 8.8 451 160 22.9 24.5 0.94 0.76 22 19 2.06 2.13 8.6 8.9 450 460 153 163 22.3 23.7 0.89 0.72 23 20 2.04 2.11 8.5 8.9 446 455 152 162 20.5 21.9 0.86 0.70 23 20 2.03 2.10 8.5 8.8 441 451 150 160
67 23.0 0.78 18 2.06 8.6 450 153 22.4 0.75 19 2.04 8.5 446 152 20.6 0.72 20 2.03 8.5 441 150
kW = Total system power Amps = outdoor unit amps (comp.+fan)
26.4 0.75 20 2.06 8.4 388 160 25.6 0.72 21 2.04 8.4 384 158 23.7 0.69 22 2.02 8.3 380 156
71 26.6 0.58 16 2.06 8.4 388 160 25.8 0.55 16 2.04 8.4 384 158 23.8 0.53 17 2.02 8.3 380 156
115ºF
Product Specifications
Expanded Cooling Data — DSXC160361A* / CA*F3743*6A* +TXV / MBVC1600** Low Stage (cont.)
9
10
www.goodmanmfg.com
34.5 0.82 19 2.14 8.1 232 116 33.5 0.78 20 2.12 8.0 230 115 30.9 0.75 20 2.10 8.0 227 114
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1043
1200
1356
59 33.9 0.72 17 2.14 8.1 232 116 32.9 0.68 17 2.12 8.0 230 115 30.4 0.66 18 2.10 8.0 227 114
Airflow MBh S/T ∆T kW 1356 Amps HI PR Lo PR MBh S/T ∆T kW 1200 Amps HI PR Lo PR MBh S/T ∆T 1043 kW Amps HI PR Lo PR
35.5 0.73 18 2.18 8.3 249 120 34.5 0.70 18 2.17 8.2 247 119 31.8 0.67 19 2.15 8.2 244 117
63 35.1 0.60 14 2.18 8.3 249 120 34.1 0.57 15 2.17 8.2 247 119 31.5 0.55 15 2.15 8.2 244 117 38.4 0.55 14 2.25 8.6 253 131 37.3 0.53 15 2.24 8.5 250 129 34.4 0.51 15 2.22 8.4 248 128
67 38.5 0.42 11 2.25 8.6 253 131 37.4 0.40 11 2.24 8.5 250 129 34.5 0.38 12 2.22 8.4 248 128 41.2 0.36 10 2.33 8.9 259 139 40.0 0.34 10 2.31 8.8 256 138 37.0 0.33 11 2.29 8.7 253 136
71 33.7 0.85 19 2.31 8.8 262 119 32.7 0.81 20 2.29 8.7 260 118 30.2 0.78 21 2.27 8.6 257 117
59 33.1 0.74 17 2.31 8.8 262 119 32.2 0.71 17 2.29 8.7 260 118 29.7 0.68 18 2.27 8.6 257 117 34.7 0.76 18 2.36 9.0 282 123 33.7 0.72 19 2.34 8.9 279 122 31.1 0.70 19 2.32 8.8 276 121
63 34.3 0.62 14 2.36 9.0 282 123 33.3 0.59 15 2.34 8.9 279 122 30.8 0.57 15 2.32 8.8 276 121 37.5 0.57 15 2.43 9.3 286 135 36.4 0.55 15 2.41 9.2 283 133 33.6 0.53 16 2.39 9.1 280 132
67 37.6 0.43 11 2.43 9.3 286 135 36.5 0.41 11 2.41 9.2 283 133 33.7 0.40 12 2.39 9.1 280 132
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
40.3 0.37 10 2.51 9.6 292 143 39.1 0.35 11 2.49 9.5 289 142 36.1 0.34 11 2.47 9.4 286 140
71 32.9 0.87 19 2.45 9.5 298 124 31.9 0.83 20 2.43 9.4 295 122 29.5 0.80 21 2.41 9.3 292 121
59 32.3 0.76 17 2.45 9.5 298 124 31.4 0.73 18 2.43 9.4 295 122 29.0 0.70 18 2.41 9.3 292 121 33.8 0.78 18 2.51 9.7 321 127 32.9 0.74 19 2.49 9.6 317 126 30.3 0.71 19 2.47 9.6 314 125
36.6 0.59 15 2.59 10.0 325 139 35.6 0.56 15 2.57 10.0 322 138 32.8 0.54 16 2.55 9.9 319 136
32.1 0.90 19 2.58 10.1 340 127 31.1 0.85 20 2.56 10.1 336 126 28.7 0.82 21 2.54 10.0 333 124
33.0 0.80 18 2.64 10.4 365 131 32.1 0.76 19 2.62 10.3 362 130 29.6 0.74 19 2.60 10.2 358 128
35.7 0.61 15 2.73 10.7 370 143 34.7 0.58 15 2.71 10.6 367 141 32.0 0.56 16 2.68 10.5 363 140
38.4 0.39 10 2.82 11.1 379 152 37.2 0.37 11 2.80 11.0 375 151 34.4 0.36 11 2.78 10.9 371 149
30.5 0.93 19 2.69 10.8 367 129 29.6 0.89 20 2.67 10.7 363 128 27.3 0.85 21 2.65 10.6 360 127
59 30.0 0.82 17 2.69 10.8 367 129 29.1 0.78 17 2.67 10.7 363 128 26.9 0.75 18 2.65 10.6 360 127
Shaded area reflects ACCA (TVA) conditions
39.3 0.38 10 2.68 10.4 332 148 38.2 0.36 11 2.66 10.3 329 147 35.2 0.35 11 2.63 10.2 326 145
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 33.5 36.7 31.5 32.7 35.8 0.64 0.44 0.79 0.66 0.46 14 11 17 15 11 2.51 2.59 2.58 2.64 2.73 9.7 10.0 10.1 10.4 10.7 321 325 340 365 370 127 139 127 131 143 32.5 35.6 30.6 31.7 34.8 0.61 0.42 0.75 0.63 0.43 15 11 18 15 12 2.49 2.57 2.56 2.62 2.71 9.6 10.0 10.1 10.3 10.6 317 322 336 362 367 126 138 126 130 141 30.0 32.9 28.3 29.3 32.1 0.59 0.41 0.72 0.61 0.42 16 12 18 16 12 2.47 2.55 2.54 2.60 2.68 9.6 9.9 10.0 10.2 10.5 314 319 333 358 363 125 136 124 128 140 31.4 0.83 18 2.76 11.1 394 133 30.5 0.79 19 2.73 11.0 390 132 28.1 0.76 19 2.71 10.9 387 131
63 31.1 0.68 14 2.76 11.1 394 133 30.2 0.65 15 2.73 11.0 390 132 27.8 0.63 15 2.71 10.9 387 131 34.0 0.63 14 2.85 11.4 400 146 33.0 0.60 15 2.82 11.3 396 144 30.4 0.58 16 2.80 11.2 392 143
67 34.0 0.47 11 2.85 11.4 400 146 33.0 0.45 11 2.82 11.3 396 144 30.5 0.44 12 2.80 11.2 392 143
105ºF
28.2 0.94 18 2.79 11.4 435 133 27.4 0.89 19 2.77 11.3 430 131 25.3 0.86 19 2.74 11.2 426 130
59 27.8 0.82 16 2.79 11.4 435 133 26.9 0.79 16 2.77 11.3 430 131 24.9 0.76 17 2.74 11.2 426 130 29.1 0.84 17 2.85 11.7 467 137 28.2 0.80 17 2.83 11.6 463 135 26.0 0.77 18 2.81 11.5 458 134
63 28.8 0.69 13 2.85 11.7 467 137 27.9 0.66 14 2.83 11.6 463 135 25.8 0.63 14 2.81 11.5 458 134 31.5 0.63 14 2.95 12.1 474 149 30.5 0.61 14 2.93 12.0 469 148 28.2 0.58 14 2.90 11.9 465 146
67 31.5 0.48 10 2.95 12.1 474 149 30.6 0.45 11 2.93 12.0 469 148 28.2 0.44 11 2.90 11.9 465 146 33.8 0.41 9 3.05 12.6 484 159 32.8 0.39 10 3.03 12.4 480 157 30.3 0.38 10 3.00 12.3 475 156
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
36.4 0.40 10 2.95 11.9 409 155 35.4 0.39 10 2.92 11.7 405 154 32.7 0.37 11 2.90 11.6 401 152
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160361A* / CA*F3743*6A* +TXV / MBVC1600** High Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
35.7 0.94 23 2.14 8.1 232 116 34.7 0.90 24 2.12 8.0 230 115 32.0 0.86 24 2.10 8.0 227 114
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1043
1200
1356
59 35.1 0.90 21 2.14 8.1 232 116 34.1 0.85 22 2.12 8.0 230 115 31.4 0.82 23 2.10 8.0 227 114
Airflow MBh S/T ∆T kW 1356 Amps HI PR Lo PR MBh S/T ∆T kW 1200 Amps HI PR Lo PR MBh S/T ∆T 1043 kW Amps HI PR Lo PR
36.4 0.91 22 2.18 8.3 249 120 35.3 0.86 23 2.17 8.2 247 119 32.6 0.83 24 2.15 8.2 244 117
63 35.9 0.84 20 2.18 8.3 249 120 34.8 0.80 21 2.17 8.2 247 119 32.1 0.77 22 2.15 8.2 244 117 38.1 0.82 21 2.25 8.6 253 131 37.0 0.78 22 2.24 8.5 250 129 34.2 0.75 23 2.22 8.4 248 128
67 38.3 0.68 18 2.25 8.6 253 131 37.2 0.65 19 2.24 8.5 250 129 34.3 0.63 19 2.22 8.4 248 128 40.7 0.66 18 2.33 8.9 259 139 39.5 0.63 19 2.31 8.8 256 138 36.4 0.61 20 2.29 8.7 253 136
71 41.0 0.51 14 2.33 8.9 259 139 39.8 0.49 15 2.31 8.8 256 138 36.7 0.47 15 2.29 8.7 253 136 34.9 0.97 23 2.31 8.8 262 119 33.9 0.93 24 2.29 8.7 260 118 31.3 0.89 25 2.27 8.6 257 117
59 34.3 0.93 22 2.31 8.8 262 119 33.3 0.88 23 2.29 8.7 260 118 30.7 0.85 23 2.27 8.6 257 117 35.6 0.94 23 2.36 9.0 282 123 34.5 0.90 24 2.34 8.9 279 122 31.9 0.86 24 2.32 8.8 276 121
63 35.0 0.87 21 2.36 9.0 282 123 34.0 0.83 22 2.34 8.9 279 122 31.4 0.80 22 2.32 8.8 276 121 37.2 0.85 21 2.43 9.3 286 135 36.1 0.81 22 2.41 9.2 283 133 33.4 0.78 23 2.39 9.1 280 132
67 37.4 0.71 18 2.43 9.3 286 135 36.3 0.68 19 2.41 9.2 283 133 33.5 0.65 19 2.39 9.1 280 132
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
39.7 0.69 19 2.51 9.6 292 143 38.6 0.66 19 2.49 9.5 289 142 35.6 0.63 20 2.47 9.4 286 140
71 40.0 0.53 14 2.51 9.6 292 143 38.8 0.50 15 2.49 9.5 289 142 35.8 0.49 15 2.47 9.4 286 140 34.0 1.00 23 2.45 9.5 298 124 33.1 0.95 24 2.43 9.4 295 122 30.5 0.92 25 2.41 9.3 292 121
59 33.5 0.95 22 2.45 9.5 298 124 32.5 0.91 23 2.43 9.4 295 122 30.0 0.87 23 2.41 9.3 292 121 34.7 0.96 23 2.51 9.7 321 127 33.7 0.92 24 2.49 9.6 317 126 31.1 0.89 24 2.47 9.6 314 125
36.3 0.87 21 2.59 10.0 325 139 35.3 0.83 22 2.57 10.0 322 138 32.6 0.80 23 2.55 9.9 319 136
33.2 1.00 23 2.58 10.1 340 127 32.2 0.98 24 2.56 10.1 336 126 29.8 0.95 25 2.54 10.0 333 124
33.9 0.99 23 2.64 10.4 365 131 32.9 0.95 24 2.62 10.3 362 130 30.3 0.91 24 2.60 10.2 358 128
35.5 0.90 22 2.73 10.7 370 143 34.4 0.86 23 2.71 10.6 367 141 31.8 0.82 23 2.68 10.5 363 140
37.8 0.73 19 2.82 11.1 379 152 36.7 0.69 20 2.80 11.0 375 151 33.9 0.67 20 2.78 10.9 371 149
71 38.1 0.56 14 2.82 11.1 379 152 37.0 0.53 15 2.80 11.0 375 151 34.1 0.52 16 2.78 10.9 371 149 31.6 1.00 21 2.69 10.8 367 129 30.6 1.00 23 2.67 10.7 363 128 28.3 0.98 24 2.65 10.6 360 127
59 31.0 1.00 21 2.69 10.8 367 129 30.1 0.97 22 2.67 10.7 363 128 27.8 0.94 23 2.65 10.6 360 127
Shaded area reflects AHRI (TVA) conditions
38.8 0.70 19 2.68 10.4 332 148 37.6 0.67 19 2.66 10.3 329 147 34.7 0.65 20 2.63 10.2 326 145
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.2 36.5 39.0 32.6 33.4 35.6 0.89 0.73 0.54 1.00 0.92 0.75 21 18 14 22 21 18 2.51 2.59 2.68 2.58 2.64 2.73 9.7 10.0 10.4 10.1 10.4 10.7 321 325 332 340 365 370 127 139 148 127 131 143 33.2 35.5 37.9 31.7 32.4 34.6 0.85 0.69 0.52 0.94 0.88 0.71 22 19 15 23 22 19 2.49 2.57 2.66 2.56 2.62 2.71 9.6 10.0 10.3 10.1 10.3 10.6 317 322 329 336 362 367 126 138 147 126 130 141 30.6 32.7 35.0 29.3 29.9 31.9 0.82 0.67 0.50 0.90 0.85 0.69 22 19 15 23 22 19 2.47 2.55 2.63 2.54 2.60 2.68 9.6 9.9 10.2 10.0 10.2 10.5 314 319 326 333 358 363 125 136 145 124 128 140 32.2 1.00 22 2.76 11.1 394 133 31.2 0.98 24 2.73 11.0 390 132 28.8 0.95 24 2.71 10.9 387 131
63 31.7 0.96 21 2.76 11.1 394 133 30.8 0.91 21 2.73 11.0 390 132 28.4 0.88 22 2.71 10.9 387 131 33.7 0.93 21 2.85 11.4 400 146 32.7 0.89 22 2.82 11.3 396 144 30.2 0.86 23 2.80 11.2 392 143
67 33.9 0.78 18 2.85 11.4 400 146 32.9 0.74 19 2.82 11.3 396 144 30.3 0.72 19 2.80 11.2 392 143
105ºF
29.2 1.00 20 2.79 11.4 435 133 28.4 1.00 22 2.77 11.3 430 131 26.2 0.99 23 2.74 11.2 426 130
59 28.7 1.00 19 2.79 11.4 435 133 27.9 0.98 21 2.77 11.3 430 131 25.7 0.95 21 2.74 11.2 426 130 29.8 1.00 20 2.85 11.7 467 137 28.9 0.99 22 2.83 11.6 463 135 26.7 0.96 22 2.81 11.5 458 134
63 29.4 0.96 19 2.85 11.7 467 137 28.5 0.92 20 2.83 11.6 463 135 26.3 0.89 21 2.81 11.5 458 134 31.2 33.3 0.94 0.76 20 17 2.95 3.05 12.1 12.6 474 484 149 159 30.3 32.3 0.89 0.73 21 18 2.93 3.03 12.0 12.4 469 480 148 157 28.0 29.8 0.86 0.70 21 18 2.90 3.00 11.9 12.3 465 475 146 156
67 71 31.4 33.5 0.78 0.59 17 13 2.95 3.05 12.1 12.6 474 484 149 159 30.4 32.5 0.75 0.56 17 14 2.93 3.03 12.0 12.4 469 480 148 157 28.1 30.0 0.72 0.54 18 14 2.90 3.00 11.9 12.3 465 475 146 156
kW = Total system power Amps = outdoor unit amps (comp.+fan)
35.9 0.75 18 2.95 11.9 409 155 34.9 0.72 19 2.92 11.7 405 154 32.2 0.69 20 2.90 11.6 401 152
71 36.2 0.58 14 2.95 11.9 409 155 35.1 0.55 15 2.92 11.7 405 154 32.4 0.53 15 2.90 11.6 401 152
115ºF
Product Specifications
Expanded Cooling Data — DSXC160361A* / CA*F3743*6A* +TXV / MBVC1600** High Stage (cont.)
11
12
www.goodmanmfg.com
34.5 0.83 21 2.04 8.1 227 122 33.5 0.79 22 2.03 8.1 225 120 30.9 0.77 23 2.01 8.0 223 119
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
963
1100
1238
59 33.9 0.73 18 2.04 8.1 227 122 32.9 0.70 19 2.03 8.1 225 120 30.4 0.67 20 2.01 8.0 223 119
Airflow MBh S/T ∆T kW 1238 Amps HI PR Lo PR MBh S/T ∆T kW 1100 Amps HI PR Lo PR MBh S/T ∆T 963 kW Amps HI PR Lo PR
35.5 0.75 20 2.09 8.3 244 125 34.5 0.71 20 2.07 8.2 242 124 31.8 0.69 21 2.05 8.2 239 123
63 35.2 0.61 16 2.09 8.3 244 125 34.1 0.58 17 2.07 8.2 242 124 31.5 0.56 17 2.05 8.2 239 123 38.4 0.56 16 2.16 8.6 248 137 37.3 0.54 17 2.14 8.5 245 136 34.4 0.52 17 2.12 8.4 243 134
67 38.5 0.42 12 2.16 8.6 248 137 37.4 0.40 13 2.14 8.5 245 136 34.5 0.39 13 2.12 8.4 243 134 41.3 0.36 11 2.23 8.9 253 146 40.1 0.35 12 2.21 8.8 251 144 37.0 0.33 12 2.19 8.7 248 143
71 33.7 0.86 22 2.21 8.8 257 125 32.7 0.82 23 2.19 8.7 254 124 30.2 0.79 23 2.17 8.6 252 123
59 33.1 0.76 19 2.21 8.8 257 125 32.2 0.72 19 2.19 8.7 254 124 29.7 0.70 20 2.17 8.6 252 123 34.7 0.77 20 2.26 9.0 276 129 33.7 0.74 21 2.24 8.9 273 128 31.1 0.71 21 2.22 8.8 270 127
63 34.3 0.63 16 2.26 9.0 276 129 33.3 0.61 17 2.24 8.9 273 128 30.8 0.58 17 2.22 8.8 270 127 37.5 0.58 16 2.33 9.3 280 141 36.4 0.56 17 2.31 9.2 277 140 33.6 0.54 17 2.29 9.1 274 138
67 37.6 0.44 12 2.33 9.3 280 141 36.5 0.42 13 2.31 9.2 277 140 33.7 0.40 13 2.29 9.1 274 138
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
40.3 0.38 11 2.41 9.6 286 150 39.1 0.36 12 2.39 9.5 283 149 36.1 0.35 12 2.37 9.4 280 147
71 32.9 0.89 22 2.35 9.5 292 129 31.9 0.84 23 2.33 9.4 289 128 29.5 0.81 23 2.31 9.3 286 127
59 32.3 0.78 19 2.35 9.5 292 129 31.4 0.74 19 2.33 9.4 289 128 29.0 0.72 20 2.31 9.3 286 127 33.9 0.79 20 2.41 9.7 314 134 32.9 0.76 21 2.38 9.6 311 132 30.3 0.73 21 2.36 9.6 308 131
36.6 0.60 16 2.49 10.0 318 146 35.6 0.57 17 2.47 10.0 315 144 32.8 0.55 17 2.44 9.9 312 143
32.1 0.91 22 2.48 10.1 332 133 31.1 0.87 23 2.46 10.1 329 132 28.8 0.84 23 2.44 10.0 326 130
33.0 0.82 20 2.54 10.4 357 137 32.1 0.78 21 2.51 10.3 354 136 29.6 0.75 21 2.49 10.2 350 134
35.8 0.62 16 2.62 10.7 362 150 34.7 0.59 17 2.60 10.6 359 148 32.0 0.57 17 2.58 10.5 355 147
38.4 0.40 11 2.71 11.1 370 159 37.3 0.38 12 2.69 11.0 367 158 34.4 0.37 12 2.67 10.9 363 156
30.5 0.95 21 2.59 10.8 374 136 29.6 0.90 22 2.57 10.7 370 134 27.3 0.87 23 2.54 10.6 367 133
59 30.0 0.83 19 2.59 10.8 374 136 29.1 0.80 19 2.57 10.7 370 134 26.9 0.77 20 2.54 10.6 367 133
Shaded area reflects ACCA (TVA) conditions
39.3 0.39 11 2.57 10.4 325 155 38.2 0.37 12 2.55 10.3 322 154 35.2 0.35 12 2.53 10.2 319 152
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 33.5 36.7 31.5 32.7 35.8 0.65 0.45 0.80 0.67 0.47 16 12 19 16 12 2.41 2.49 2.48 2.54 2.62 9.7 10.0 10.1 10.4 10.7 314 318 332 357 362 134 146 133 137 150 32.5 35.7 30.6 31.7 34.8 0.62 0.43 0.77 0.64 0.44 17 13 20 17 13 2.38 2.47 2.46 2.51 2.60 9.6 10.0 10.1 10.3 10.6 311 315 329 354 359 132 144 132 136 148 30.0 32.9 28.3 29.3 32.1 0.60 0.41 0.74 0.62 0.43 17 13 20 17 13 2.36 2.44 2.44 2.49 2.58 9.6 9.9 10.0 10.2 10.5 308 312 326 350 355 131 143 130 134 147 31.4 0.85 20 2.65 11.0 402 140 30.5 0.81 21 2.62 10.9 398 138 28.1 0.78 21 2.60 10.8 394 137
63 31.1 0.70 16 2.65 11.0 402 140 30.2 0.66 17 2.62 10.9 398 138 27.8 0.64 17 2.60 10.8 394 137 34.0 0.64 16 2.74 11.4 408 153 33.0 0.61 17 2.71 11.3 404 151 30.4 0.59 17 2.69 11.2 400 150
67 34.0 0.48 12 2.74 11.4 408 153 33.0 0.46 13 2.71 11.3 404 151 30.5 0.44 13 2.69 11.2 400 150
105ºF
28.2 0.96 20 2.68 11.4 419 139 27.4 0.91 21 2.66 11.3 415 138 25.3 0.88 21 2.64 11.2 411 136
59 27.8 0.84 17 2.68 11.4 419 139 27.0 0.80 18 2.66 11.3 415 138 24.9 0.77 18 2.64 11.2 411 136 29.1 0.86 18 2.74 11.7 450 143 28.2 0.82 19 2.72 11.6 446 142 26.0 0.79 20 2.70 11.5 441 140
63 28.8 0.70 15 2.74 11.7 450 143 27.9 0.67 16 2.72 11.6 446 142 25.8 0.65 16 2.70 11.5 441 140 31.5 0.65 15 2.84 12.1 457 156 30.5 0.62 16 2.81 12.0 452 155 28.2 0.60 16 2.79 11.9 448 153
67 31.5 0.49 11 2.84 12.1 457 156 30.6 0.46 12 2.81 12.0 452 155 28.3 0.45 12 2.79 11.9 448 153 33.8 0.42 10 2.94 12.5 467 167 32.8 0.40 11 2.91 12.4 462 165 30.3 0.38 11 2.89 12.3 458 163
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
36.5 0.41 11 2.83 11.8 417 163 35.4 0.39 12 2.81 11.7 413 161 32.7 0.38 12 2.78 11.6 409 159
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160481A* / CA*F4961*6A* +TXV / MBVC2000** Low Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
35.7 0.96 25 2.04 8.1 227 122 34.7 0.91 26 2.03 8.1 225 120 32.0 0.88 26.9 2.01 8.0 223 119
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
963
1100
1238
59 35.1 0.91 24 2.04 8.1 227 122 34.1 0.87 25 2.03 8.1 225 120 31.5 0.84 25 2.01 8.0 223 119
Airflow MBh S/T ∆T kW 1238 Amps HI PR Lo PR MBh S/T ∆T kW 1100 Amps HI PR Lo PR MBh S/T ∆T 963 kW Amps HI PR Lo PR
36.4 0.92 25 2.09 8.3 244 125 35.3 0.88 26 2.07 8.2 242 124 32.6 0.85 26 2.05 8.2 239 123
63 35.9 0.86 23 2.09 8.3 244 125 34.8 0.82 24 2.07 8.2 242 124 32.1 0.79 24 2.05 8.2 239 123 38.1 0.83 24 2.16 8.6 248 137 37.0 0.80 25 2.14 8.5 245 136 34.2 0.77 25 2.12 8.4 243 134
67 38.3 0.70 20 2.16 8.6 248 137 37.2 0.67 21 2.14 8.5 245 136 34.3 0.64 21 2.12 8.4 243 134 40.7 0.68 20 2.23 8.9 253 146 39.5 0.65 21 2.21 8.8 251 144 36.5 0.62 22 2.19 8.7 248 143
71 41.0 0.52 16 2.23 8.9 253 146 39.8 0.50 17 2.21 8.8 251 144 36.7 0.48 17 2.19 8.7 248 143 34.9 0.99 26 2.21 8.8 257 125 33.9 0.95 27 2.19 8.7 254 124 31.3 0.91 27 2.17 8.6 252 123
59 34.3 0.95 24 2.21 8.8 257 125 33.3 0.90 25 2.19 8.7 254 124 30.7 0.87 26 2.17 8.6 252 123 35.6 0.96 25 2.26 9.0 276 129 34.5 0.91 26 2.24 8.9 273 128 31.9 0.88 27 2.22 8.8 270 127
63 35.0 0.89 23 2.26 9.0 276 129 34.0 0.85 24 2.24 8.9 273 128 31.4 0.82 24 2.22 8.8 270 127 37.2 0.86 24 2.33 9.3 280 141 36.2 0.82 25 2.31 9.2 277 140 33.4 0.80 25 2.29 9.1 274 138
67 37.4 0.72 20 2.33 9.3 280 141 36.3 0.69 21 2.31 9.2 277 140 33.5 0.66 21 2.29 9.1 274 138
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
39.7 0.70 21 2.41 9.6 286 150 38.6 0.67 22 2.39 9.5 283 149 35.6 0.65 22 2.37 9.4 280 147
71 40.0 0.54 16 2.41 9.6 286 150 38.8 0.52 17 2.39 9.5 283 149 35.9 0.50 17 2.37 9.4 280 147 34.1 1.00 25 2.35 9.5 292 129 33.1 0.97 27 2.33 9.4 289 128 30.5 0.94 27 2.31 9.3 286 127
59 33.5 1.00 25 2.35 9.5 292 129 32.5 0.93 25 2.33 9.4 289 128 30.0 0.89 26 2.31 9.3 286 127 34.7 0.98 25 2.41 9.7 314 134 33.7 0.94 26 2.38 9.6 311 132 31.1 0.90 27 2.36 9.6 308 131
36.4 0.89 24 2.49 10.0 318 146 35.3 0.85 25 2.47 10.0 315 144 32.6 0.82 25 2.44 9.9 312 143
33.2 1.00 25 2.48 10.1 332 133 32.3 1.00 27 2.46 10.1 329 132 29.8 0.97 27 2.44 10.0 326 130
33.9 1.00 25 2.54 10.4 357 137 32.9 0.97 27 2.51 10.3 354 136 30.3 0.93 27 2.49 10.2 350 134
35.5 0.92 24 2.62 10.7 362 150 34.4 0.87 25 2.60 10.6 359 148 31.8 0.84 26 2.58 10.5 355 147
37.8 0.74 21 2.71 11.1 370 159 36.7 0.71 22 2.69 11.0 367 158 33.9 0.68 22 2.67 10.9 363 156
71 38.1 0.57 16 2.71 11.1 370 159 37.0 0.55 17 2.69 11.0 367 158 34.1 0.53 17 2.67 10.9 363 156 31.6 1.00 23 2.59 10.8 374 136 30.6 1.00 26 2.57 10.7 370 134 28.3 1.00 27 2.54 10.6 367 133
59 31.0 1.00 23 2.59 10.8 374 136 30.1 0.99 25 2.57 10.7 370 134 27.8 0.96 25 2.54 10.6 367 133
Shaded area reflects AHRI (TVA) conditions
38.8 0.72 21 2.57 10.4 325 155 37.7 0.69 22 2.55 10.3 322 154 34.8 0.66 22 2.53 10.2 319 152
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.2 36.5 39.1 32.7 33.4 35.6 0.91 0.74 0.55 1.00 0.94 0.77 23 20 16 24 23 20 2.41 2.49 2.57 2.48 2.54 2.62 9.7 10.0 10.4 10.1 10.4 10.7 314 318 325 332 357 362 134 146 155 133 137 150 33.2 35.5 37.9 31.7 32.4 34.6 0.87 0.71 0.53 0.96 0.90 0.73 24 21 17 25 24 21 2.38 2.47 2.55 2.46 2.51 2.60 9.6 10.0 10.3 10.1 10.3 10.6 311 315 322 329 354 359 132 144 154 132 136 148 30.6 32.7 35.0 29.3 29.9 31.9 0.84 0.68 0.51 0.92 0.86 0.70 25 21 17 26 25 21 2.36 2.44 2.53 2.44 2.49 2.58 9.6 9.9 10.2 10.0 10.2 10.5 308 312 319 326 350 355 131 143 152 130 134 147 32.2 1.00 24 2.65 11.0 402 140 31.2 1.00 26 2.62 10.9 398 138 28.8 0.97 27 2.60 10.8 394 137
63 31.7 1.00 24 2.65 11.0 402 140 30.8 0.93 24 2.62 10.9 398 138 28.4 0.90 24 2.60 10.8 394 137 33.7 0.95 24 2.74 11.4 408 153 32.7 0.91 25 2.71 11.3 404 151 30.2 0.87 25 2.69 11.2 400 150
67 33.9 0.79 20 2.74 11.4 408 153 32.9 0.76 21 2.71 11.3 404 151 30.3 0.73 21 2.69 11.2 400 150
105ºF
29.2 1.00 22 2.68 11.4 419 139 28.4 1.00 24 2.66 11.3 415 138 26.2 1.00 25 2.64 11.2 411 136
59 28.7 1.00 21 2.68 11.4 419 139 27.9 1.00 23 2.66 11.3 415 138 25.8 0.96 24 2.64 11.2 411 136 29.8 1.00 22 2.74 11.7 450 143 28.9 1.00 24 2.72 11.6 446 142 26.7 0.98 25 2.70 11.5 441 140
63 29.4 1.00 22 2.74 11.7 450 143 28.5 0.94 22 2.72 11.6 446 142 26.3 0.90 23 2.70 11.5 441 140 31.2 33.3 0.96 0.78 22 19 2.84 2.94 12.1 12.5 457 467 156 167 30.3 32.3 0.91 0.74 23 20 2.81 2.91 12.0 12.4 452 462 155 165 28.0 29.8 0.88 0.71 24 20 2.79 2.89 11.9 12.3 448 458 153 163
67 71 31.4 33.5 0.80 0.60 19 15 2.84 2.94 12.1 12.5 457 467 156 167 30.5 32.6 0.76 0.57 19 16 2.81 2.91 12.0 12.4 452 462 155 165 28.1 30.1 0.74 0.55 20 16 2.79 2.89 11.9 12.3 448 458 153 163
kW = Total system power Amps = outdoor unit amps (comp.+fan)
35.9 0.77 21 2.83 11.8 417 163 34.9 0.73 21 2.81 11.7 413 161 32.2 0.71 22 2.78 11.6 409 159
71 36.2 0.59 16 2.83 11.8 417 163 35.1 0.57 17 2.81 11.7 413 161 32.4 0.55 17 2.78 11.6 409 159
115ºF
Product Specifications
Expanded Cooling Data — DSXC160481A* / CA*F4961*6A* +TXV / MBVC2000** Low Stage (cont.)
13
14
www.goodmanmfg.com
46.8 0.87 22 2.94 11.4 241 120 45.5 0.83 22 2.92 11.3 238 119 42.0 0.80 23 2.89 11.2 236 117
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1356
1550
1744
59 46.1 0.77 19 2.94 11.4 241 120 44.7 0.73 19 2.92 11.3 238 119 41.3 0.71 20 2.89 11.2 236 117
Airflow MBh S/T ∆T kW 1744 Amps HI PR Lo PR MBh S/T ∆T kW 1550 Amps HI PR Lo PR MBh S/T ∆T 1356 kW Amps HI PR Lo PR
48.2 0.78 20 3.01 11.7 259 124 46.8 0.74 21 2.98 11.6 256 122 43.2 0.72 21 2.96 11.5 254 121
63 47.7 0.64 16 3.01 11.7 259 124 46.3 0.61 17 2.98 11.6 256 122 42.8 0.59 17 2.96 11.5 254 121 52.2 0.59 16 3.10 12.1 262 135 50.7 0.56 17 3.08 12.0 260 133 46.8 0.54 17 3.05 11.8 257 132
67 52.3 0.44 12 3.10 12.1 262 135 50.8 0.42 13 3.08 12.0 260 133 46.9 0.41 13 3.05 11.8 257 132 56.0 0.38 11 3.21 12.5 268 144 54.4 0.36 12 3.18 12.4 265 142 50.2 0.35 12 3.16 12.3 263 141
71 45.7 0.90 22 3.18 12.3 272 123 44.4 0.86 23 3.15 12.2 269 122 41.0 0.83 23 3.12 12.1 267 121
59 45.0 0.80 19 3.18 12.3 272 123 43.7 0.76 20 3.15 12.2 269 122 40.3 0.73 20 3.12 12.1 267 121 47.1 0.81 20 3.25 12.6 292 127 45.7 0.77 21 3.22 12.5 289 126 42.2 0.74 21 3.19 12.4 287 125
63 46.6 0.66 16 3.25 12.6 292 127 45.3 0.63 17 3.22 12.5 289 126 41.8 0.61 17 3.19 12.4 287 125 51.0 0.61 16 3.36 13.0 297 139 49.5 0.58 17 3.33 12.9 294 137 45.7 0.56 17 3.30 12.8 291 136
67 51.1 0.46 12 3.36 13.0 297 139 49.6 0.44 13 3.33 12.9 294 137 45.8 0.42 13 3.30 12.8 291 136
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
54.7 0.39 11 3.47 13.5 303 148 53.1 0.38 12 3.44 13.4 300 146 49.0 0.36 12 3.41 13.3 297 145
71 44.7 0.93 22 3.38 13.4 309 127 43.4 0.88 23 3.36 13.3 306 126 40.0 0.85 23 3.33 13.2 303 125
59 43.9 0.82 19 3.38 13.4 309 127 42.6 0.78 20 3.36 13.3 306 126 39.4 0.75 20 3.33 13.2 303 125 46.0 0.83 20 3.46 13.7 333 131 44.6 0.79 21 3.43 13.6 329 130 41.2 0.76 21 3.40 13.5 326 129
49.8 0.63 16 3.58 14.2 337 144 48.3 0.60 17 3.55 14.0 334 142 44.6 0.58 17 3.52 13.9 331 141
43.6 0.96 22 3.57 14.3 352 131 42.3 0.91 23 3.54 14.2 349 130 39.0 0.88 23 3.51 14.1 345 128
44.9 0.86 20 3.65 14.7 379 135 43.6 0.82 21 3.62 14.5 375 134 40.2 0.79 21 3.59 14.4 371 132
48.6 0.65 17 3.77 15.2 384 147 47.1 0.62 17 3.74 15.0 380 146 43.5 0.60 18 3.71 14.9 376 144
52.1 0.42 11 3.90 15.7 393 157 50.6 0.40 12 3.87 15.6 389 155 46.7 0.38 12 3.84 15.4 385 154
41.4 0.99 22 3.72 15.2 396 133 40.2 0.95 23 3.69 15.1 392 132 37.1 0.91 23 3.66 15.0 388 131
59 40.7 0.87 19 3.72 15.2 396 133 39.5 0.83 20 3.69 15.1 392 132 36.5 0.80 20 3.66 15.0 388 131
Shaded area reflects ACCA (TVA) conditions
53.4 0.40 11 3.70 14.7 345 153 51.9 0.39 12 3.67 14.6 341 151 47.9 0.37 12 3.64 14.4 338 150
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 45.5 49.9 42.8 44.4 48.7 0.68 0.47 0.84 0.70 0.49 16 12 19 16 12 3.46 3.58 3.57 3.65 3.77 13.7 14.2 14.3 14.7 15.2 333 337 352 379 384 131 144 131 135 147 44.2 48.4 41.6 43.1 47.2 0.65 0.45 0.80 0.67 0.46 17 13 20 17 13 3.43 3.55 3.54 3.62 3.74 13.6 14.0 14.2 14.5 15.0 329 334 349 375 380 130 142 130 134 146 40.8 44.7 38.4 39.8 43.6 0.63 0.43 0.77 0.65 0.45 17 13 20 17 13 3.40 3.52 3.51 3.59 3.71 13.5 13.9 14.1 14.4 14.9 326 331 345 371 376 129 141 128 132 144 42.6 0.89 20 3.81 15.6 426 138 41.4 0.85 21 3.78 15.5 422 136 38.2 0.82 21 3.74 15.3 418 135
63 42.2 0.73 16 3.81 15.6 426 138 41.0 0.70 17 3.78 15.5 422 136 37.8 0.67 17 3.74 15.3 418 135 46.1 0.67 16 3.94 16.1 432 150 44.8 0.64 17 3.91 16.0 428 149 41.3 0.62 17 3.87 15.8 424 147
67 46.2 0.51 12 3.94 16.1 432 150 44.9 0.48 13 3.91 16.0 428 149 41.4 0.46 13 3.87 15.8 424 147
105ºF
38.3 1.00 20 3.86 16.1 444 137 37.2 0.96 21 3.83 16.0 439 135 34.4 0.92 21 3.79 15.9 435 134
59 37.7 0.88 18 3.86 16.1 444 137 36.6 0.84 18 3.83 16.0 439 135 33.8 0.81 19 3.79 15.9 435 134 39.5 0.90 19 3.95 16.5 477 141 38.3 0.85 19 3.91 16.4 472 140 35.4 0.82 20 3.88 16.2 468 138
63 39.1 0.74 15 3.95 16.5 477 141 37.9 0.70 16 3.91 16.4 472 140 35.0 0.68 16 3.88 16.2 468 138 42.7 0.68 15 4.08 17.1 484 154 41.5 0.65 16 4.05 16.9 479 152 38.3 0.62 16 4.01 16.8 474 151
67 42.8 0.51 12 4.08 17.1 484 154 41.6 0.49 12 4.05 16.9 479 152 38.4 0.47 12 4.01 16.8 474 151 45.9 0.44 11 4.23 17.8 495 164 44.5 0.42 11 4.19 17.6 490 162 41.1 0.40 11 4.15 17.4 485 161
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
49.5 0.43 11 4.08 16.8 442 160 48.1 0.41 12 4.04 16.6 437 158 44.4 0.40 12 4.01 16.4 433 157
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160481A* / CA*F4961*6A* +TXV / MBVC2000** High Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
48.5 1.00 26 2.94 11.4 241 120 47.1 0.96 27 2.92 11.3 238 119 43.5 0.92 27 2.89 11.2 236 117
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1356
1550
1744
59 47.7 0.96 24 2.94 11.4 241 120 46.3 0.91 25 2.92 11.3 238 119 42.7 0.88 25 2.89 11.2 236 117
Airflow MBh S/T ∆T kW 1744 Amps HI PR Lo PR MBh S/T ∆T kW 1550 Amps HI PR Lo PR MBh S/T ∆T 1356 kW Amps HI PR Lo PR
49.4 0.97 25 3.01 11.7 259 124 48.0 0.92 26 2.98 11.6 256 122 44.3 0.89 27 2.96 11.5 254 121
63 48.7 0.90 23 3.01 11.7 259 124 47.3 0.86 24 2.98 11.6 256 122 43.6 0.83 24 2.96 11.5 254 121 51.8 0.87 24 3.10 12.1 262 135 50.3 0.83 25 3.08 12.0 260 133 46.4 0.80 25 3.05 11.8 257 132
67 52.0 0.73 20 3.10 12.1 262 135 50.5 0.70 21 3.08 12.0 260 133 46.6 0.67 21 3.05 11.8 257 132 55.2 0.71 21 3.21 12.5 268 144 53.6 0.68 21 3.18 12.4 265 142 49.5 0.65 22 3.16 12.3 263 141
71 55.6 0.55 16 3.21 12.5 268 144 54.0 0.52 17 3.18 12.4 265 142 49.9 0.50 17 3.16 12.3 263 141 47.4 1.00 25 3.18 12.3 272 123 46.0 0.99 27 3.15 12.2 269 122 42.5 0.96 28 3.12 12.1 267 121
59 46.6 1.00 25 3.18 12.3 272 123 45.2 0.95 25 3.15 12.2 269 122 41.7 0.91 26 3.12 12.1 267 121 48.3 1.00 25 3.25 12.6 292 127 46.9 0.96 27 3.22 12.5 289 126 43.3 0.92 27 3.19 12.4 287 125
63 47.6 0.93 23 3.25 12.6 292 127 46.2 0.89 24 3.22 12.5 289 126 42.6 0.86 25 3.19 12.4 287 125 50.6 0.91 24 3.36 13.0 297 139 49.1 0.86 25 3.33 12.9 294 137 45.3 0.83 26 3.30 12.8 291 136
67 50.8 0.76 20 3.36 13.0 297 139 49.4 0.72 21 3.33 12.9 294 137 45.6 0.70 21 3.30 12.8 291 136
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
54.0 0.73 21 3.47 13.5 303 148 52.4 0.70 22 3.44 13.4 300 146 48.4 0.68 22 3.41 13.3 297 145
71 54.3 0.57 16 3.47 13.5 303 148 52.8 0.54 17 3.44 13.4 300 146 48.7 0.52 17 3.41 13.3 297 145 46.2 1.00 24 3.38 13.4 309 127 44.9 1.00 27 3.36 13.3 306 126 41.4 0.98 28 3.33 13.2 303 125
59 45.5 1.00 24 3.38 13.4 309 127 44.1 0.97 25 3.36 13.3 306 126 40.7 0.93 26 3.33 13.2 303 125 47.1 1.00 25 3.46 13.7 333 131 45.8 0.98 27 3.43 13.6 329 130 42.2 0.95 27 3.40 13.5 326 129
49.4 0.93 24 3.58 14.2 337 144 47.9 0.89 25 3.55 14.0 334 142 44.2 0.85 26 3.52 13.9 331 141
45.1 1.00 24 3.57 14.3 352 131 43.8 1.00 26 3.54 14.2 349 130 40.4 1.00 27 3.51 14.1 345 128
46.0 1.00 24 3.65 14.7 379 135 44.7 1.00 26 3.62 14.5 375 134 41.2 0.98 27 3.59 14.4 371 132
48.2 0.96 24 3.77 15.2 384 147 46.8 0.91 25 3.74 15.0 380 146 43.2 0.88 26 3.71 14.9 376 144
51.4 0.78 21 3.90 15.7 393 157 49.9 0.74 22 3.87 15.6 389 155 46.0 0.71 22 3.84 15.4 385 154
71 51.8 0.60 16 3.90 15.7 393 157 50.2 0.57 17 3.87 15.6 389 155 46.4 0.55 17 3.84 15.4 385 154 42.9 1.00 23 3.72 15.2 396 133 41.6 1.00 25 3.69 15.1 392 132 38.4 1.00 26 3.66 15.0 388 131
59 42.1 1.00 22 3.72 15.2 396 133 40.9 1.00 24 3.69 15.1 392 132 37.8 1.00 26 3.66 15.0 388 131
Shaded area reflects AHRI (TVA) conditions
52.7 0.75 21 3.70 14.7 345 153 51.1 0.72 22 3.67 14.6 341 151 47.2 0.69 22 3.64 14.4 338 150
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.4 49.6 53.0 44.3 45.3 48.4 0.95 0.78 0.58 1.00 1.00 0.80 23 20 16 23 24 20 3.46 3.58 3.70 3.57 3.65 3.77 13.7 14.2 14.7 14.3 14.7 15.2 333 337 345 352 379 384 131 144 153 131 135 147 45.1 48.2 51.5 43.1 44.0 47.0 0.91 0.74 0.55 1.00 0.94 0.76 24 21 17 26 24 21 3.43 3.55 3.67 3.54 3.62 3.74 13.6 14.0 14.6 14.2 14.5 15.0 329 334 341 349 375 380 130 142 151 130 134 146 41.6 44.5 47.5 39.7 40.6 43.4 0.88 0.71 0.53 0.97 0.91 0.74 25 22 17 26 25 22 3.40 3.52 3.64 3.51 3.59 3.71 13.5 13.9 14.4 14.1 14.4 14.9 326 331 338 345 371 376 129 141 150 128 132 144 43.7 1.00 23 3.81 15.6 426 138 42.4 1.00 25 3.78 15.5 422 136 39.2 1.00 27 3.74 15.3 418 135
63 43.0 1.00 23 3.81 15.6 426 138 41.8 0.97 24 3.78 15.5 422 136 38.6 0.94 25 3.74 15.3 418 135 45.8 0.99 24 3.94 16.1 432 150 44.4 0.95 25 3.91 16.0 428 149 41.0 0.91 25 3.87 15.8 424 147
67 46.0 0.83 20 3.94 16.1 432 150 44.7 0.79 21 3.91 16.0 428 149 41.2 0.76 21 3.87 15.8 424 147
105ºF
39.7 1.00 21 3.86 16.1 444 137 38.5 1.00 23 3.83 16.0 439 135 35.6 1.00 24 3.79 15.9 435 134
59 39.0 1.00 21 3.86 16.1 444 137 37.9 1.00 22 3.83 16.0 439 135 35.0 1.01 24 3.79 15.9 435 134 40.5 1.00 21 3.95 16.5 477 141 39.3 1.00 23 3.91 16.4 472 140 36.3 1.00 25 3.88 16.2 468 138
63 39.9 1.00 21 3.95 16.5 477 141 38.7 0.98 23 3.91 16.4 472 140 35.7 0.95 23 3.88 16.2 468 138 42.4 45.2 1.00 0.81 22 19 4.08 4.23 17.1 17.8 484 495 154 164 41.2 43.9 0.96 0.78 23 20 4.05 4.19 16.9 17.6 479 490 152 162 38.0 40.5 0.92 0.75 24 21 4.01 4.15 16.8 17.4 474 485 151 161
67 71 42.6 45.5 0.84 0.63 19 15 4.08 4.23 17.1 17.8 484 495 154 164 41.4 44.2 0.80 0.60 20 16 4.05 4.19 16.9 17.6 479 490 152 162 38.2 40.8 0.77 0.58 20 16 4.01 4.15 16.8 17.4 474 485 151 161
kW = Total system power Amps = outdoor unit amps (comp.+fan)
48.8 0.81 21 4.08 16.8 442 160 47.4 0.77 22 4.04 16.6 437 158 43.7 0.74 22 4.01 16.4 433 157
71 49.2 0.62 16 4.08 16.8 442 160 47.7 0.59 17 4.04 16.6 437 158 44.1 0.57 17 4.01 16.4 433 157
115ºF
Product Specifications
Expanded Cooling Data — DSXC160481A* / CA*F4961*6A* +TXV / MBVC2000** High Stage (cont.)
15
16
www.goodmanmfg.com
42.5 0.85 21 2.61 10.1 231 120 41.3 0.81 22 2.59 10.0 228 119 38.1 0.78 22 2.57 9.9 226 118
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1225
1400
1575
59 41.8 0.75 18 2.61 10.1 231 120 40.6 0.71 19 2.59 10.0 228 119 37.4 0.69 19 2.57 9.9 226 118
Airflow MBh S/T ∆T kW 1575 Amps HI PR Lo PR MBh S/T ∆T kW 1400 Amps HI PR Lo PR MBh S/T ∆T 1225 kW Amps HI PR Lo PR
43.8 0.76 19 2.67 10.3 248 124 42.5 0.73 20 2.65 10.2 246 123 39.2 0.70 21 2.63 10.1 243 122
63 43.3 0.62 16 2.67 10.3 248 124 42.0 0.60 16 2.65 10.2 246 123 38.8 0.57 17 2.63 10.1 243 122 47.4 0.58 16 2.76 10.7 252 136 46.0 0.55 17 2.74 10.6 249 134 42.4 0.53 17 2.72 10.5 247 133
67 47.5 0.43 12 2.76 10.7 252 136 46.1 0.41 12 2.74 10.6 249 134 42.5 0.40 13 2.72 10.5 247 133 50.8 0.37 11 2.86 11.1 257 144 49.3 0.35 11 2.83 11.0 255 143 45.5 0.34 12 2.81 10.9 252 142
71 41.5 0.88 21 2.83 10.9 253 124 40.3 0.84 22 2.80 10.8 251 123 37.2 0.81 23 2.78 10.7 248 122
59 40.8 0.78 18 2.83 10.9 253 124 39.6 0.74 19 2.80 10.8 251 123 36.6 0.71 20 2.78 10.7 248 122 42.7 0.79 20 2.89 11.2 272 128 41.5 0.75 20 2.87 11.1 270 127 38.3 0.72 21 2.84 11.0 267 125
63 42.3 0.65 16 2.89 11.2 272 128 41.1 0.62 17 2.87 11.1 270 127 37.9 0.60 17 2.84 11.0 267 125 46.3 0.60 16 2.99 11.6 276 140 44.9 0.57 17 2.97 11.5 274 138 41.5 0.55 17 2.94 11.4 271 137
67 46.3 0.45 12 2.99 11.6 276 140 45.0 0.43 13 2.97 11.5 274 138 41.5 0.41 13 2.94 11.4 271 137
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
49.6 0.38 11 3.10 12.0 282 149 48.2 0.37 12 3.07 11.9 280 147 44.5 0.35 12 3.04 11.8 277 146
71 40.5 0.90 21 3.02 11.9 297 128 39.3 0.86 22 2.99 11.8 294 127 36.3 0.83 23 2.97 11.7 291 126
59 39.8 0.80 18 3.02 11.9 297 128 38.7 0.76 19 2.99 11.8 294 127 35.7 0.73 20 2.97 11.7 291 126 41.7 0.81 20 3.09 12.2 319 132 40.5 0.77 21 3.06 12.1 316 131 37.4 0.74 21 3.03 12.0 313 130
45.2 0.61 16 3.19 12.6 323 144 43.8 0.58 17 3.17 12.5 320 143 40.5 0.56 17 3.14 12.4 317 142
39.5 0.93 22 3.19 12.7 338 132 38.4 0.89 22 3.16 12.6 335 130 35.4 0.86 23 3.13 12.5 331 129
40.7 0.83 20 3.26 13.0 363 136 39.5 0.80 21 3.23 12.9 360 134 36.5 0.77 21 3.20 12.8 356 133
44.1 0.63 16 3.37 13.5 368 148 42.8 0.60 17 3.34 13.4 365 147 39.5 0.58 17 3.31 13.2 361 145
47.3 0.41 11 3.49 14.0 377 158 45.9 0.39 12 3.46 13.9 373 156 42.4 0.37 12 3.43 13.7 369 155
37.6 0.97 21 3.33 14.9 380 134 36.5 0.92 22 3.30 14.7 376 133 33.7 0.89 22 3.27 14.6 373 132
59 36.9 0.85 18 3.33 14.9 380 134 35.9 0.81 19 3.30 14.7 376 133 33.1 0.78 19 3.27 14.6 373 132
Shaded area reflects ACCA (TVA) conditions
48.5 0.39 11 3.31 13.1 331 154 47.1 0.38 12 3.28 13.0 327 152 43.4 0.36 12 3.25 12.8 324 151
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 41.3 45.2 38.9 40.3 44.1 0.66 0.46 0.82 0.69 0.47 16 12 19 16 12 3.09 3.19 3.19 3.26 3.37 12.2 12.6 12.7 13.0 13.5 319 323 338 363 368 132 144 132 136 148 40.1 43.9 37.7 39.1 42.9 0.63 0.44 0.78 0.65 0.45 17 13 19 17 13 3.06 3.17 3.16 3.23 3.34 12.1 12.5 12.6 12.9 13.4 316 320 335 360 365 131 143 130 134 147 37.0 40.5 34.8 36.1 39.6 0.61 0.42 0.75 0.63 0.44 17 13 20 17 13 3.03 3.14 3.13 3.20 3.31 12.0 12.4 12.5 12.8 13.2 313 317 331 356 361 130 142 129 133 145 38.7 0.87 20 3.41 15.2 409 139 37.5 0.83 20 3.38 15.1 405 137 34.6 0.80 21 3.35 15.0 401 136
63 38.3 0.71 16 3.41 15.2 409 139 37.2 0.68 17 3.38 15.1 405 137 34.3 0.65 17 3.35 15.0 401 136 41.9 0.66 16 3.52 15.8 415 151 40.6 0.63 17 3.49 15.6 410 150 37.5 0.60 17 3.46 15.5 406 148
67 41.9 0.49 12 3.52 15.8 415 151 40.7 0.47 13 3.49 15.6 410 150 37.6 0.45 13 3.46 15.5 406 148
105ºF
34.8 0.98 20 3.45 15.7 439 138 33.8 0.93 21 3.42 15.6 435 136 31.2 0.90 21 3.39 15.4 431 135
59 34.2 0.86 17 3.45 15.7 439 138 33.2 0.82 18 3.42 15.6 435 136 30.7 0.79 18 3.39 15.4 431 135 35.8 0.87 18 3.53 16.1 472 142 34.8 0.83 19 3.50 15.9 468 141 32.1 0.80 19 3.47 15.8 463 139
63 35.5 0.72 15 3.53 16.1 472 142 34.4 0.68 15 3.50 15.9 468 141 31.8 0.66 16 3.47 15.8 463 139 38.8 0.66 15 3.66 16.7 479 155 37.6 0.63 16 3.62 16.5 474 153 34.7 0.61 16 3.59 16.3 469 152
67 38.8 0.50 11 3.66 16.7 479 155 37.7 0.47 12 3.62 16.5 474 153 34.8 0.46 12 3.59 16.3 469 152 41.6 0.43 10 3.79 17.3 490 165 40.4 0.41 11 3.75 17.1 485 163 37.3 0.39 11 3.72 17.0 480 162
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
44.9 0.42 11 3.65 16.4 424 161 43.6 0.40 12 3.62 16.2 419 159 40.3 0.39 12 3.58 16.1 415 158
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160601A* / CA*F4961*6A* + TXV / MBVC2000** Low Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
44.0 0.98 25 2.61 10.1 231 120 42.7 0.93 26 2.59 10.0 228 119 39.4 0.90 26.6 2.57 9.9 226 118
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1225
1400
1575
59 43.3 0.93 24 2.61 10.1 231 120 42.0 0.89 25 2.59 10.0 228 119 38.8 0.86 25 2.57 9.9 226 118
Airflow MBh S/T ∆T kW 1575 Amps HI PR Lo PR MBh S/T ∆T kW 1400 Amps HI PR Lo PR MBh S/T ∆T 1225 kW Amps HI PR Lo PR
44.9 0.94 25 2.67 10.3 248 124 43.6 0.90 26 2.65 10.2 246 123 40.2 0.87 26 2.63 10.1 243 122
63 44.2 0.87 23 2.67 10.3 248 124 42.9 0.83 24 2.65 10.2 246 123 39.6 0.80 24 2.63 10.1 243 122 47.0 0.85 23 2.76 10.7 252 136 45.6 0.81 24 2.74 10.6 249 134 42.1 0.78 25 2.72 10.5 247 133
67 47.2 0.71 20 2.76 10.7 252 136 45.8 0.68 20 2.74 10.6 249 134 42.3 0.65 21 2.72 10.5 247 133 50.1 0.69 20 2.86 11.1 257 144 48.7 0.66 21 2.83 11.0 255 143 44.9 0.64 21 2.81 10.9 252 142
71 50.5 0.53 16 2.86 11.1 257 144 49.0 0.51 16 2.83 11.0 255 143 45.2 0.49 17 2.81 10.9 252 142 43.0 1.00 25 2.83 10.9 253 124 41.7 0.97 26 2.80 10.8 251 123 38.5 0.93 27 2.78 10.7 248 122
59 42.2 0.97 24 2.83 10.9 253 124 41.0 0.92 25 2.80 10.8 251 123 37.9 0.89 25 2.78 10.7 248 122 43.8 0.98 25 2.89 11.2 272 128 42.5 0.93 26 2.87 11.1 270 127 39.3 0.90 26 2.84 11.0 267 125
63 43.2 0.91 23 2.89 11.2 272 128 41.9 0.86 24 2.87 11.1 270 127 38.7 0.83 24 2.84 11.0 267 125 45.9 0.88 24 2.99 11.6 276 140 44.6 0.84 25 2.97 11.5 274 138 41.1 0.81 25 2.94 11.4 271 137
67 46.1 0.74 20 2.99 11.6 276 140 44.8 0.70 21 2.97 11.5 274 138 41.3 0.68 21 2.94 11.4 271 137
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
49.0 0.72 20 3.10 12.0 282 149 47.5 0.68 21 3.07 11.9 280 147 43.9 0.66 22 3.04 11.8 277 146
71 49.3 0.55 16 3.10 12.0 282 149 47.9 0.53 17 3.07 11.9 280 147 44.2 0.51 17 3.04 11.8 277 146 42.0 1.00 24 3.02 11.9 297 128 40.7 0.99 27 2.99 11.8 294 127 37.6 0.96 27 2.97 11.7 291 126
59 41.2 1.00 24 3.02 11.9 297 128 40.0 0.95 25 2.99 11.8 294 127 37.0 0.91 25 2.97 11.7 291 126 42.8 1.00 25 3.09 12.2 319 132 41.5 0.96 26 3.06 12.1 316 131 38.3 0.92 27 3.03 12.0 313 130
44.8 0.90 24 3.19 12.6 323 144 43.5 0.86 25 3.17 12.5 320 143 40.1 0.83 25 3.14 12.4 317 142
40.9 1.00 24 3.19 12.7 338 132 39.7 1.00 26 3.16 12.6 335 130 36.7 0.99 27 3.13 12.5 331 129
41.7 1.00 24 3.26 13.0 363 136 40.5 0.99 26 3.23 12.9 360 134 37.4 0.95 27 3.20 12.8 356 133
43.7 0.93 24 3.37 13.5 368 148 42.4 0.89 25 3.34 13.4 365 147 39.2 0.86 25 3.31 13.2 361 145
46.6 0.76 21 3.49 14.0 377 158 45.3 0.72 21 3.46 13.9 373 156 41.8 0.70 22 3.43 13.7 369 155
71 47.0 0.58 16 3.49 14.0 377 158 45.6 0.56 17 3.46 13.9 373 156 42.1 0.54 17 3.43 13.7 369 155 38.9 1.00 23 3.33 14.9 380 134 37.8 1.00 25 3.30 14.7 376 133 34.8 1.00 26 3.27 14.6 373 132
59 38.2 1.00 22 3.33 14.9 380 134 37.1 1.00 24 3.30 14.7 376 133 34.3 0.98 25 3.27 14.6 373 132
Shaded area reflects AHRI (TVA) conditions
47.8 0.73 20 3.31 13.1 331 154 46.4 0.70 21 3.28 13.0 327 152 42.8 0.68 22 3.25 12.8 324 151
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 42.1 45.0 48.1 40.2 41.1 43.9 0.93 0.76 0.57 1.00 0.96 0.78 23 20 16 23 23 20 3.09 3.19 3.31 3.19 3.26 3.37 12.2 12.6 13.1 12.7 13.0 13.5 319 323 331 338 363 368 132 144 154 132 136 148 40.9 43.7 46.7 39.1 39.9 42.6 0.89 0.72 0.54 0.98 0.92 0.74 24 21 17 25 24 21 3.06 3.17 3.28 3.16 3.23 3.34 12.1 12.5 13.0 12.6 12.9 13.4 316 320 327 335 360 365 131 143 152 130 134 147 37.8 40.3 43.1 36.1 36.8 39.4 0.85 0.70 0.52 0.94 0.88 0.72 24 21 17 25 24 21 3.03 3.14 3.25 3.13 3.20 3.31 12.0 12.4 12.8 12.5 12.8 13.2 313 317 324 331 356 361 130 142 151 129 133 145 39.6 1.00 23 3.41 15.2 409 139 38.5 1.00 25 3.38 15.1 405 137 35.5 0.99 26 3.35 15.0 401 136
63 39.1 1.00 23 3.41 15.2 409 139 37.9 0.95 24 3.38 15.1 405 137 35.0 0.92 24 3.35 15.0 401 136 41.5 0.97 23 3.52 15.8 415 151 40.3 0.92 24 3.49 15.6 410 150 37.2 0.89 25 3.46 15.5 406 148
67 41.7 0.81 20 3.52 15.8 415 151 40.5 0.77 21 3.49 15.6 410 150 37.4 0.75 21 3.46 15.5 406 148
105ºF
36.0 1.00 21 3.45 15.7 439 138 35.0 1.00 23 3.42 15.6 435 136 32.3 1.00 24 3.39 15.4 431 135
59 35.4 1.00 21 3.45 15.7 439 138 34.4 1.00 23 3.42 15.6 435 136 31.7 0.98 23 3.39 15.4 431 135 36.7 1.00 21 3.53 16.1 472 142 35.7 1.00 23 3.50 15.9 468 141 32.9 1.00 25 3.47 15.8 463 139
63 36.2 1.00 21 3.53 16.1 472 142 35.1 0.96 22 3.50 15.9 468 141 32.4 0.92 22 3.47 15.8 463 139 38.5 41.0 0.98 0.79 22 19 3.66 3.79 16.7 17.3 479 490 155 165 37.3 39.8 0.93 0.76 23 20 3.62 3.75 16.5 17.1 474 485 153 163 34.5 36.8 0.90 0.73 23 20 3.59 3.72 16.3 17.0 469 480 152 162
67 71 38.7 41.3 0.82 0.61 18 15 3.66 3.79 16.7 17.3 479 490 155 165 37.5 40.1 0.78 0.58 19 15 3.62 3.75 16.5 17.1 474 485 153 163 34.6 37.0 0.75 0.56 20 16 3.59 3.72 16.3 17.0 469 480 152 162
kW = Total system power Amps = outdoor unit amps (comp.+fan)
44.3 0.79 20 3.65 16.4 424 161 43.0 0.75 21 3.62 16.2 419 159 39.7 0.72 22 3.58 16.1 415 158
71 44.6 0.61 16 3.65 16.4 424 161 43.3 0.58 16 3.62 16.2 419 159 40.0 0.56 17 3.58 16.1 415 158
115ºF
Product Specifications
Expanded Cooling Data — DSXC160601A* / CA*F4961*6A* + TXV / MBVC2000** Low Stage (cont.)
17
18
www.goodmanmfg.com
56.8 0.87 22 3.94 14.2 247 118 55.1 0.83 23 3.91 14.0 245 116 50.9 0.80 24 3.87 13.9 242 115
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1575
1800
2025
59 55.9 0.77 19 3.94 14.2 247 118 54.2 0.73 20 3.91 14.0 245 116 50.1 0.70 21 3.87 13.9 242 115
Airflow MBh S/T ∆T kW 2025 Amps HI PR Lo PR MBh S/T ∆T kW 1800 Amps HI PR Lo PR MBh S/T ∆T 1575 kW Amps HI PR Lo PR
58.5 0.78 21 4.02 14.5 266 121 56.8 0.74 22 3.99 14.4 263 120 52.4 0.72 22 3.96 14.3 260 119
63 57.9 0.64 17 4.02 14.5 266 121 56.2 0.61 18 3.99 14.4 263 120 51.9 0.59 18 3.96 14.3 260 119 63.3 0.59 17 4.15 15.0 269 132 61.5 0.56 18 4.12 14.9 267 131 56.7 0.54 18 4.08 14.7 264 130
67 63.4 0.44 13 4.15 15.0 269 132 61.6 0.42 13 4.12 14.9 267 131 56.8 0.41 14 4.08 14.7 264 130 67.9 0.38 12 4.29 15.6 275 141 66.0 0.36 12 4.25 15.5 273 140 60.9 0.35 12 4.22 15.3 270 138
71 55.5 0.90 23 4.25 15.4 271 121 53.9 0.86 24 4.21 15.2 269 120 49.7 0.83 24 4.18 15.1 266 119
59 54.6 0.79 20 4.25 15.4 271 121 53.0 0.76 20 4.21 15.2 269 120 48.9 0.73 21 4.18 15.1 266 119 57.1 0.81 21 4.34 15.8 292 125 55.5 0.77 22 4.30 15.6 289 124 51.2 0.74 22 4.27 15.5 286 122
63 56.5 0.66 17 4.34 15.8 292 125 54.9 0.63 18 4.30 15.6 289 124 50.7 0.61 18 4.27 15.5 286 122 61.8 0.61 17 4.48 16.3 296 136 60.0 0.58 18 4.44 16.1 293 135 55.4 0.56 18 4.41 16.0 290 134
67 62.0 0.46 13 4.48 16.3 296 136 60.1 0.44 13 4.44 16.1 293 135 55.5 0.42 14 4.41 16.0 290 134
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
66.4 0.39 12 4.63 16.9 302 145 64.4 0.37 12 4.59 16.8 299 144 59.5 0.36 13 4.55 16.6 296 142
71 54.2 0.93 23 4.52 16.8 318 125 52.6 0.88 24 4.48 16.6 314 124 48.5 0.85 24 4.44 16.4 311 123
59 53.3 0.81 20 4.52 16.8 318 125 51.7 0.78 20 4.48 16.6 314 124 47.7 0.75 21 4.44 16.4 311 123 55.8 0.83 21 4.62 17.2 342 129 54.1 0.79 22 4.58 17.0 338 128 50.0 0.76 22 4.54 16.9 335 126
60.4 0.63 17 4.77 17.8 346 141 58.6 0.60 18 4.73 17.6 343 139 54.1 0.58 18 4.69 17.4 340 138
52.8 0.95 23 4.76 18.0 362 128 51.3 0.91 24 4.72 17.8 358 127 47.3 0.88 24 4.68 17.6 355 126
54.4 0.85 21 4.86 18.4 389 132 52.8 0.81 22 4.82 18.2 385 131 48.8 0.79 22 4.78 18.1 381 130
58.9 0.65 17 5.03 19.0 395 145 57.2 0.62 18 4.98 18.9 391 143 52.8 0.59 18 4.94 18.7 387 142
63.2 0.42 12 5.20 19.8 403 154 61.4 0.40 12 5.15 19.6 399 153 56.6 0.38 13 5.11 19.4 395 151
50.2 0.99 23 4.96 21.0 407 131 48.7 0.95 24 4.92 20.8 403 130 45.0 0.91 24 4.88 20.6 399 128
59 49.4 0.87 20 4.96 21.0 407 131 47.9 0.83 20 4.92 20.8 403 130 44.2 0.80 21 4.88 20.6 399 128
Shaded area reflects ACCA (TVA) conditions
64.8 0.40 12 4.93 18.5 354 150 62.9 0.38 12 4.89 18.3 350 149 58.1 0.37 13 4.85 18.1 347 147
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 55.2 60.5 52.0 53.9 59.0 0.68 0.47 0.84 0.70 0.49 17 13 20 17 13 4.62 4.77 4.76 4.86 5.03 17.2 17.8 18.0 18.4 19.0 342 346 362 389 395 129 141 128 132 145 53.6 58.7 50.4 52.3 57.3 0.65 0.45 0.80 0.67 0.46 18 13 21 18 14 4.58 4.73 4.72 4.82 4.98 17.0 17.6 17.8 18.2 18.9 338 343 358 385 391 128 139 127 131 143 49.5 54.2 46.6 48.3 52.9 0.63 0.43 0.77 0.65 0.45 18 14 21 18 14 4.54 4.69 4.68 4.78 4.94 16.9 17.4 17.6 18.1 18.7 335 340 355 381 387 126 138 126 130 142 51.7 0.89 21 5.07 21.6 438 135 50.2 0.85 22 5.03 21.4 433 134 46.3 0.82 22 4.99 21.1 429 132
63 51.2 0.73 17 5.07 21.6 438 135 49.7 0.69 18 5.03 21.4 433 134 45.8 0.67 18 4.99 21.1 429 132 55.9 0.67 17 5.24 22.3 444 148 54.3 0.64 18 5.20 22.1 439 146 50.1 0.62 18 5.16 21.9 435 145
67 56.1 0.50 13 5.24 22.3 444 148 54.4 0.48 13 5.20 22.1 439 146 50.2 0.46 14 5.16 21.9 435 145
105ºF
46.5 1.00 21 5.14 22.2 470 134 45.1 0.95 22 5.09 22.0 466 133 41.7 0.92 22 5.05 21.8 461 132
59 45.7 0.88 18 5.14 22.2 470 134 44.4 0.84 19 5.09 22.0 466 133 41.0 0.81 19 5.05 21.8 461 132 47.9 0.89 19 5.25 22.8 506 138 46.5 0.85 20 5.21 22.6 501 137 42.9 0.82 21 5.17 22.3 496 136
63 47.4 0.73 16 5.25 22.8 506 138 46.0 0.70 16 5.21 22.6 501 137 42.5 0.68 17 5.17 22.3 496 136 51.8 0.68 16 5.43 23.6 513 151 50.3 0.65 17 5.39 23.4 508 150 46.4 0.62 17 5.34 23.1 503 148
67 51.9 0.51 12 5.43 23.6 513 151 50.4 0.49 12 5.39 23.4 508 150 46.5 0.47 13 5.34 23.1 503 148 55.6 0.44 11 5.62 24.5 524 161 54.0 0.42 11 5.57 24.3 519 159 49.8 0.40 12 5.52 24.0 514 158
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
60.0 0.43 12 5.42 23.2 454 157 58.3 0.41 12 5.38 23.0 449 156 53.8 0.40 12 5.33 22.7 445 154
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160601A*/ CA*F4961*6A* + TXV/ MBVC2000** High Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
58.8 1.00 27 3.94 14.2 247 118 57.1 0.95 28 3.91 14.0 245 116 52.7 0.92 28 3.87 13.9 242 115
MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR
1575
1800
2025
59 57.8 0.95 25 3.94 14.2 247 118 56.1 0.91 26 3.91 14.0 245 116 51.8 0.88 27 3.87 13.9 242 115
Airflow MBh S/T ∆T kW 2025 Amps HI PR Lo PR MBh S/T ∆T kW 1800 Amps HI PR Lo PR MBh S/T ∆T 1575 kW Amps HI PR Lo PR
60.0 0.97 26 4.02 14.5 266 121 58.2 0.92 27 3.99 14.4 263 120 53.7 0.89 28 3.96 14.3 260 119
63 59.1 0.90 24 4.02 14.5 266 121 57.4 0.85 25 3.99 14.4 263 120 52.9 0.82 25 3.96 14.3 260 119 62.8 0.87 25 4.15 15.0 269 132 61.0 0.83 26 4.12 14.9 267 131 56.3 0.80 26 4.08 14.7 264 130
67 63.1 0.73 21 4.15 15.0 269 132 61.3 0.70 22 4.12 14.9 267 131 56.6 0.67 22 4.08 14.7 264 130 67.0 0.71 22 4.29 15.6 275 141 65.0 0.67 22 4.25 15.5 273 140 60.0 0.65 23 4.22 15.3 270 138
71 67.5 0.54 17 4.29 15.6 275 141 65.5 0.52 17 4.25 15.5 273 140 60.5 0.50 18 4.22 15.3 270 138 57.5 1.00 26 4.25 15.4 271 121 55.8 0.99 28 4.21 15.2 269 120 51.5 0.95 29 4.18 15.1 266 119
59 56.5 1.00 26 4.25 15.4 271 121 54.8 0.94 26 4.21 15.2 269 120 50.6 0.91 27 4.18 15.1 266 119 58.6 1.00 27 4.34 15.8 292 125 56.9 0.95 28 4.30 15.6 289 124 52.5 0.92 28 4.27 15.5 286 122
63 57.7 0.93 24 4.34 15.8 292 125 56.0 0.88 25 4.30 15.6 289 124 51.7 0.85 26 4.27 15.5 286 122 61.3 0.90 25 4.48 16.3 296 136 59.6 0.86 26 4.44 16.1 293 135 55.0 0.83 27 4.41 16.0 290 134
67 61.6 0.76 21 4.48 16.3 296 136 59.9 0.72 22 4.44 16.1 293 135 55.2 0.69 22 4.41 16.0 290 134
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
65.4 0.73 22 4.63 16.9 302 145 63.5 0.70 23 4.59 16.8 299 144 58.6 0.67 23 4.55 16.6 296 142
71 65.9 0.56 17 4.63 16.9 302 145 64.0 0.54 18 4.59 16.8 299 144 59.1 0.52 18 4.55 16.6 296 142 56.1 1.00 25 4.52 16.8 318 125 54.5 1.00 28 4.48 16.6 314 124 50.3 0.98 29 4.44 16.4 311 123
59 55.1 1.00 25 4.52 16.8 318 125 53.5 0.97 26 4.48 16.6 314 124 49.4 0.93 27 4.44 16.4 311 123 57.2 1.00 26 4.62 17.2 342 129 55.5 0.98 28 4.58 17.0 338 128 51.2 0.94 28 4.54 16.9 335 126
59.9 0.93 25 4.77 17.8 346 141 58.1 0.88 26 4.73 17.6 343 139 53.7 0.85 27 4.69 17.4 340 138
54.7 1.00 25 4.76 18.0 362 128 53.1 1.00 27 4.72 17.8 358 127 49.0 1.00 29 4.68 17.6 355 126
55.8 1.00 25 4.86 18.4 389 132 54.2 1.00 28 4.82 18.2 385 131 50.0 0.97 28 4.78 18.1 381 130
58.4 0.96 25 5.03 19.0 395 145 56.7 0.91 26 4.98 18.9 391 143 52.3 0.88 27 4.94 18.7 387 142
62.3 0.78 22 5.20 19.8 403 154 60.5 0.74 23 5.15 19.6 399 153 55.8 0.71 23 5.11 19.4 395 151
71 62.8 0.60 17 5.20 19.8 403 154 60.9 0.57 18 5.15 19.6 399 153 56.2 0.55 18 5.11 19.4 395 151 52.0 1.00 24 4.96 21.0 407 131 50.5 1.00 26 4.92 20.8 403 130 46.6 1.00 27 4.88 20.6 399 128
59 51.1 1.00 23 4.96 21.0 407 131 49.6 1.00 25 4.92 20.8 403 130 45.8 1.00 27 4.88 20.6 399 128
Shaded area reflects AHRI (TVA) conditions
63.9 0.75 22 4.93 18.5 354 150 62.0 0.72 23 4.89 18.3 350 149 57.2 0.69 23 4.85 18.1 347 147
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 56.3 60.2 64.3 53.8 55.0 58.7 0.95 0.77 0.58 1.00 1.00 0.80 24 21 17 24 25 21 4.62 4.77 4.93 4.76 4.86 5.03 17.2 17.8 18.5 18.0 18.4 19.0 342 346 354 362 389 395 129 141 150 128 132 145 54.7 58.4 62.5 52.2 53.4 57.0 0.91 0.74 0.55 1.00 0.94 0.76 25 22 18 27 26 22 4.58 4.73 4.89 4.72 4.82 4.98 17.0 17.6 18.3 17.8 18.2 18.9 338 343 350 358 385 391 128 139 149 127 131 143 50.5 53.9 57.6 48.2 49.2 52.6 0.88 0.71 0.53 0.96 0.90 0.74 26 22 18 27 26 23 4.54 4.69 4.85 4.68 4.78 4.94 16.9 17.4 18.1 17.6 18.1 18.7 335 340 347 355 381 387 126 138 147 126 130 142 53.0 1.00 24 5.07 21.6 438 135 51.4 1.00 26 5.03 21.4 433 134 47.5 1.00 28 4.99 21.1 429 132
63 52.2 1.00 24 5.07 21.6 438 135 50.7 0.97 25 5.03 21.4 433 134 46.8 0.94 26 4.99 21.1 429 132 55.5 0.99 25 5.24 22.3 444 148 53.9 0.95 26 5.20 22.1 439 146 49.7 0.91 26 5.16 21.9 435 145
67 55.8 0.83 21 5.24 22.3 444 148 54.2 0.79 22 5.20 22.1 439 146 50.0 0.76 22 5.16 21.9 435 145
105ºF
48.2 1.00 22 5.14 22.2 470 134 46.7 1.00 24 5.09 22.0 466 133 43.1 1.00 25 5.05 21.8 461 132
59 47.3 1.00 21 5.14 22.2 470 134 45.9 1.00 23 5.09 22.0 466 133 42.4 1.01 25 5.05 21.8 461 132 49.1 1.00 22 5.25 22.8 506 138 47.7 1.00 24 5.21 22.6 501 137 44.0 1.00 26 5.17 22.3 496 136
63 48.4 1.00 22 5.25 22.8 506 138 46.9 0.98 24 5.21 22.6 501 137 43.3 0.95 24 5.17 22.3 496 136 51.4 54.8 1.00 0.81 23 20 5.43 5.62 23.6 24.5 513 524 151 161 49.9 53.2 0.95 0.77 24 21 5.39 5.57 23.4 24.3 508 519 150 159 46.1 49.1 0.92 0.75 25 21 5.34 5.52 23.1 24.0 503 514 148 158
67 71 51.7 55.2 0.84 0.63 20 16 5.43 5.62 23.6 24.5 513 524 151 161 50.2 53.6 0.80 0.60 20 16 5.39 5.57 23.4 24.3 508 519 150 159 46.3 49.5 0.77 0.58 21 17 5.34 5.52 23.1 24.0 503 514 148 158
kW = Total system power Amps = outdoor unit amps (comp.+fan)
59.2 0.81 22 5.42 23.2 454 157 57.5 0.77 23 5.38 23.0 449 156 53.1 0.74 23 5.33 22.7 445 154
71 59.6 0.62 17 5.42 23.2 454 157 57.9 0.59 17 5.38 23.0 449 156 53.4 0.57 18 5.33 22.7 445 154
115ºF
Product Specifications
Expanded Cooling Data — DSXC160601A*/ CA*F4961*6A* + TXV/ MBVC2000** High Stage (cont.)
19
20
www.goodmanmfg.com
1050
1217
1350
67 44.6 0.42 13 2.57 10.4 244 124 43.9 0.41 13 2.56 10.4 242 124 40.5 0.39 14 2.49 10.1 235 120
44.49 0.56 17 2.59 10.5 246 126 43.8 0.54 18 2.58 10.5 244 125 40.5 0.52 18 2.51 10.2 237 121
MBh 39.92 41.10 S/T 0.83 0.75 ∆T 23 21 kW 2.45 2.51 Amps 10.0 10.2 HI PR 217 233 LO PR 108 115 MBh 39.3 40.5 S/T 0.80 0.71 ∆T 24 22 kW 2.44 2.49 Amps 9.9 10.1 HI PR 215 231 LO PR 108 114 MBh 36.3 37.4 S/T 0.77 0.69 ∆T 24 23 kW 2.38 2.43 Amps 9.6 9.9 HI PR 209 224 LO PR 104 111
59 39.3 0.73 20 2.43 9.9 214 107 38.7 0.70 21 2.42 9.8 213 106 35.7 0.68 21 2.36 9.5 207 103
63 40.7 0.61 17 2.49 10.1 231 114 40.1 0.59 18 2.47 10.0 229 113 37.0 0.57 18 2.41 9.8 222 110
Airflow MBh S/T ∆T kW 1350 Amps HI PR LO PR MBh S/T ∆T kW 1217 Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR 47.75 0.36 12 2.68 10.9 257 134 47.0 0.35 12 2.67 10.9 255 133 43.4 0.34 13 2.60 10.6 247 129
71 38.99 0.86 23 2.65 10.8 243 114 38.4 0.83 24 2.64 10.7 241 114 35.5 0.80 25 2.57 10.4 234 110
59 38.3 0.76 20 2.63 10.7 241 113 37.8 0.73 21 2.62 10.6 239 112 34.9 0.70 21 2.55 10.3 232 109 40.14 0.77 21 2.72 11.0 262 122 39.6 0.74 22 2.70 11.0 260 121 36.5 0.71 23 2.63 10.7 252 117
63 39.7 0.63 17 2.69 10.9 259 120 39.2 0.61 18 2.68 10.9 257 120 36.1 0.59 19 2.61 10.6 249 116 43.45 0.58 17 2.81 11.4 276 133 42.8 0.56 18 2.79 11.3 274 132 39.5 0.54 19 2.72 11.0 266 128
67 43.5 0.44 13 2.78 11.3 273 132 42.9 0.42 14 2.77 11.2 271 131 39.6 0.41 14 2.69 10.9 263 127
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
46.64 0.38 12 2.90 11.8 288 142 45.9 0.36 13 2.89 11.7 286 141 42.4 0.35 13 2.81 11.4 277 136
71 38.06 0.89 23 2.83 11.7 276 119 37.5 0.85 24 2.81 11.6 274 118 34.6 0.82 25 2.74 11.3 266 115
59 37.4 0.78 20 2.81 11.6 274 118 36.9 0.75 21 2.79 11.5 272 117 34.0 0.72 21 2.72 11.2 264 113 39.19 0.79 21 2.90 12.0 297 126 38.6 0.76 22 2.88 11.9 295 126 35.6 0.73 23 2.80 11.6 286 122
42.42 0.60 17 3.00 12.4 314 138 41.8 0.57 18 2.98 12.3 312 137 38.6 0.55 19 2.90 12.0 303 133
37.13 0.91 23 2.99 12.5 315 125 36.6 0.88 24 2.97 12.4 313 124 33.8 0.84 25 2.89 12.1 303 120
38.23 0.82 21 3.06 12.8 339 133 37.7 0.78 22 3.04 12.7 336 132 34.8 0.76 23 2.96 12.4 326 128
41.38 0.62 17 3.16 13.2 358 145 40.8 0.59 18 3.14 13.1 355 144 37.6 0.57 19 3.06 12.8 345 140
44.41 0.40 12 3.27 13.7 373 154 43.8 0.38 13 3.25 13.6 370 153 40.4 0.37 13 3.17 13.3 359 149
35.28 0.95 23 3.12 13.3 354 131 34.8 0.91 24 3.10 13.2 352 130 32.1 0.88 25 3.02 12.9 341 126
59 34.7 0.83 20 3.09 13.2 351 130 34.2 0.80 21 3.07 13.1 348 129 31.5 0.77 21 2.99 12.7 338 125
Shaded area reflects ACCA (TVA) conditions
45.52 0.39 12 3.10 12.8 328 147 44.9 0.37 13 3.08 12.8 325 146 41.4 0.36 13 3.00 12.4 316 142
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 38.8 42.5 36.5 37.8 41.5 0.65 0.45 0.80 0.67 0.47 17 13 20 17 13 2.87 2.97 2.96 3.03 3.14 11.9 12.3 12.4 12.7 13.1 294 311 312 335 354 125 137 124 132 144 38.2 41.9 36.0 37.3 40.9 0.62 0.43 0.77 0.64 0.45 18 14 21 18 14 2.85 2.95 2.94 3.01 3.12 11.8 12.2 12.3 12.6 13.0 292 309 309 333 352 124 136 123 131 143 35.3 38.6 33.2 34.4 37.7 0.60 0.42 0.74 0.62 0.43 19 14 22 19 14 2.78 2.88 2.87 2.93 3.03 11.5 11.8 12.0 12.3 12.7 284 299 300 323 341 121 132 119 127 138 36.32 0.85 21 3.19 13.6 381 139 35.8 0.81 22 3.17 13.5 378 138 33.0 0.78 23 3.09 13.2 367 134
63 36.0 0.70 17 3.17 13.5 377 138 35.4 0.67 18 3.15 13.4 375 137 32.7 0.64 18 3.06 13.0 363 133 39.31 0.64 17 3.31 14.1 402 152 38.7 0.62 18 3.28 14.0 400 151 35.8 0.59 19 3.20 13.6 388 146
67 39.4 0.48 13 3.28 14.0 398 150 38.8 0.46 14 3.26 13.9 396 149 35.8 0.45 14 3.17 13.5 384 145
105ºF
32.68 0.96 21 3.24 14.1 391 135 32.2 0.92 22 3.22 14.0 389 134 29.7 0.88 23 3.13 13.6 377 130
59 32.1 0.84 18 3.21 14.0 387 134 31.7 0.81 19 3.19 13.9 385 133 29.2 0.78 20 3.10 13.5 373 129 33.64 0.86 20 3.31 14.4 421 144 33.1 0.82 21 3.29 14.4 418 143 30.6 0.79 21 3.20 14.0 406 139
63 33.3 0.70 16 3.28 14.3 417 143 32.8 0.67 17 3.26 14.2 414 142 30.3 0.65 17 3.18 13.8 401 137 36.42 0.65 16 3.43 14.9 445 157 35.9 0.62 17 3.41 14.8 442 156 33.1 0.60 17 3.32 14.4 428 151
67 36.5 0.49 12 3.40 14.8 440 156 35.9 0.47 13 3.38 14.7 437 155 33.2 0.45 13 3.29 14.3 424 150 39.08 0.42 11 3.55 15.5 464 167 38.5 0.40 12 3.53 15.4 461 166 35.5 0.38 12 3.43 15.0 447 161
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
42.19 0.41 12 3.42 14.6 420 162 41.6 0.40 12 3.40 14.5 417 161 38.4 0.38 13 3.31 14.1 404 156
71 -
115ºF
Product Specifications
Expanded Cooling Data — DSXC160601B* / CA*F4961*6A*+TXV / MBVC2000**-1** Low Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
44.13 0.83 25 2.64 10.7 251 128 43.5 0.80 26 2.62 10.7 249 127 40.1 0.77 27 2.56 10.4 242 124
MBh 41.34 42.14 S/T 0.96 0.92 ∆T 27 27 kW 2.50 2.55 Amps 10.1 10.4 HI PR 221 238 LO PR 110 118 MBh 40.7 41.5 S/T 0.92 0.89 ∆T 28 28 kW 2.48 2.54 Amps 10.1 10.3 HI PR 219 236 LO PR 110 117 MBh 37.6 38.3 S/T 0.88 0.85 ∆T 29 29 kW 2.42 2.47 Amps 9.8 10.0 HI PR 213 229 LO PR 106 113
1050
1217
1350
67 44.35 0.70 21 2.62 10.6 249 127 43.7 0.67 22 2.60 10.6 247 126 40.3 0.64 23 2.53 10.3 239 122
Airflow 59 63 MBh 40.63 41.51 S/T 0.91 0.86 ∆T 25 24 kW 2.47 2.53 1350 Amps 10.1 10.3 HI PR 219 235 LO PR 109 116 MBh 40.0 40.9 S/T 0.88 0.82 ∆T 26 25 kW 2.46 2.52 1217 Amps 10.0 10.2 HI PR 217 234 LO PR 109 116 MBh 36.9 37.8 S/T 0.84 0.79 ∆T 27 26 1050 kW 2.40 2.45 Amps 9.7 10.0 HI PR 211 227 LO PR 105 112 47.08 0.68 22 2.73 11.1 262 137 46.4 0.65 23 2.71 11.1 260 136 42.8 0.63 23 2.64 10.8 252 132
71 47.41 0.52 17 2.70 11.0 259 135 46.7 0.50 18 2.69 11.0 257 134 43.1 0.48 18 2.62 10.7 250 130 40.38 0.99 27 2.70 11.0 248 117 39.8 0.95 29 2.68 10.9 246 116 36.7 0.92 29 2.62 10.6 239 112
59 39.68 0.95 26 2.68 10.9 245 116 39.1 0.91 27 2.66 10.8 244 115 36.1 0.87 28 2.59 10.5 236 111 41.16 0.96 27 2.76 11.2 267 124 40.5 0.92 28 2.75 11.2 265 123 37.4 0.88 29 2.67 10.9 257 120
63 40.55 0.89 25 2.74 11.1 264 123 39.9 0.85 26 2.72 11.1 262 122 36.9 0.82 26 2.65 10.8 254 118 43.11 0.86 25 2.86 11.6 282 136 42.5 0.83 27 2.84 11.5 280 135 39.2 0.80 27 2.77 11.2 271 131
67 43.32 0.72 21 2.83 11.5 279 134 42.7 0.69 22 2.81 11.4 277 133 39.4 0.67 23 2.74 11.1 269 129
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
45.99 0.70 22 2.96 12.0 294 144 45.3 0.67 23 2.94 12.0 292 143 41.8 0.65 24 2.86 11.6 283 139
71 46.31 0.54 17 2.93 11.9 291 143 45.6 0.52 18 2.91 11.8 289 142 42.1 0.50 18 2.84 11.5 280 138 39.41 1.00 27 2.88 11.9 282 121 38.8 0.98 29 2.86 11.8 280 120 35.8 0.94 30 2.79 11.5 272 117
40.18 0.98 27 2.95 12.2 303 129 39.6 0.94 28 2.93 12.1 301 128 36.5 0.91 29 2.85 11.8 292 124
42.08 0.89 25 3.05 12.6 320 141 41.5 0.85 27 3.03 12.5 318 140 38.3 0.82 27 2.95 12.2 309 136
38.45 1.00 26 3.04 12.7 321 127 37.9 1.00 29 3.02 12.7 319 127 35.0 0.97 30 2.94 12.3 309 123
39.20 1.00 27 3.11 13.0 346 136 38.6 0.97 28 3.09 13.0 343 135 35.6 0.94 29 3.01 12.6 333 131
41.05 0.92 26 3.22 13.5 365 148 40.4 0.88 27 3.20 13.4 362 147 37.3 0.85 28 3.12 13.0 352 143
43.80 0.74 22 3.33 14.0 381 158 43.1 0.71 23 3.31 13.9 378 157 39.8 0.69 24 3.22 13.5 367 152
36.53 1.00 25 3.18 13.6 361 134 36.0 1.00 27 3.16 13.5 359 133 33.2 1.00 29 3.07 13.1 348 129
59 35.90 1.00 24 3.15 13.4 358 132 35.4 1.00 27 3.13 13.3 355 131 32.6 0.96 27 3.05 13.0 345 127
Shaded area reflects AHRI (TVA) conditions
44.89 0.72 22 3.16 13.1 334 150 44.2 0.69 23 3.14 13.0 332 149 40.8 0.66 24 3.05 12.6 322 145
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 38.74 39.58 42.29 45.21 37.79 38.62 41.26 44.11 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 26 25 21 17 26 25 22 17 2.86 2.92 3.02 3.13 3.01 3.08 3.19 3.30 11.8 12.1 12.5 13.0 12.6 12.9 13.4 13.9 279 300 317 331 318 342 361 377 120 128 139 149 126 134 147 156 38.2 39.0 41.7 44.5 37.2 38.0 40.6 43.5 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 27 26 22 18 27 26 23 18 2.84 2.90 3.00 3.11 3.00 3.07 3.17 3.28 11.7 12.0 12.4 12.9 12.5 12.8 13.3 13.8 277 298 315 329 316 340 359 374 119 127 139 148 125 133 146 155 35.2 36.0 38.5 41.1 34.4 35.1 37.5 40.1 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 28 27 23 18 28 27 23 19 2.77 2.83 2.93 3.03 2.92 2.99 3.09 3.20 11.4 11.7 12.1 12.5 12.2 12.5 12.9 13.4 269 289 306 319 306 330 348 363 116 123 134 143 122 129 141 150 37.24 1.00 25 3.25 13.9 389 142 36.7 1.00 28 3.23 13.8 386 141 33.9 0.97 29 3.15 13.4 374 137
63 36.69 0.98 24 3.22 13.8 385 141 36.1 0.93 26 3.20 13.7 382 140 33.4 0.90 26 3.12 13.3 371 135 39.00 0.95 25 3.36 14.4 411 155 38.4 0.91 26 3.34 14.3 408 154 35.5 0.88 27 3.25 13.9 395 149
67 39.20 0.79 21 3.33 14.2 406 154 38.6 0.76 22 3.31 14.1 404 152 35.6 0.73 23 3.23 13.7 392 148
105ºF
33.84 1.00 23 3.29 14.4 399 138 33.3 1.00 25 3.27 14.3 396 137 30.8 1.00 27 3.19 13.9 385 133
59 33.26 1.00 23 3.26 14.2 395 137 32.8 1.00 25 3.24 14.1 392 136 30.2 0.97 26 3.16 13.7 381 132 34.49 1.00 23 3.37 14.7 430 147 34.0 1.00 26 3.35 14.6 427 146 31.4 0.98 27 3.26 14.2 414 142
63 33.98 0.98 23 3.34 14.6 425 145 33.5 0.94 24 3.32 14.5 422 144 30.9 0.91 25 3.23 14.1 410 140 36.13 0.96 24 3.49 15.2 454 160 35.6 0.92 25 3.47 15.1 450 159 32.9 0.88 25 3.38 14.7 437 155
67 36.31 0.80 20 3.46 15.1 449 159 35.8 0.77 21 3.44 15.0 446 158 33.0 0.74 21 3.35 14.6 433 153 38.54 0.78 20 3.61 15.8 473 171 38.0 0.74 21 3.59 15.7 470 170 35.0 0.72 22 3.49 15.3 456 165
71 38.81 0.60 16 3.58 15.6 468 169 38.2 0.57 17 3.56 15.5 465 168 35.3 0.55 17 3.46 15.1 451 163
kW = Total system power Amps = outdoor unit amps (comp.+fan)
41.61 0.77 22 3.48 14.9 428 165 41.0 0.74 23 3.46 14.8 425 164 37.8 0.71 24 3.37 14.4 412 159
71 41.90 0.59 17 3.45 14.8 424 164 41.3 0.57 18 3.43 14.7 421 162 38.1 0.55 18 3.34 14.3 408 158
115ºF
Product Specifications
Expanded Cooling Data — DSXC160601B*/CA*F4961*6A*+TXV / MBVC2000**-1** Low Stage (cont.)
21
22
www.goodmanmfg.com
1575
1800
2025
67 63.4 0.43 12 3.77 14.9 262 121 61.6 0.41 13 3.74 14.8 260 120 56.8 0.40 13 3.65 14.4 252 116
63.30 0.57 16 3.81 15.0 265 122 61.5 0.55 17 3.78 14.9 262 121 56.7 0.53 17 3.68 14.5 254 117
MBh 56.80 58.48 S/T 0.84 0.76 ∆T 22 20 kW 3.60 3.68 Amps 14.2 14.6 HI PR 233 251 LO PR 105 112 MBh 55.1 56.8 S/T 0.81 0.72 ∆T 23 21 kW 3.57 3.65 Amps 14.1 14.4 HI PR 231 248 LO PR 104 111 MBh 50.9 52.4 S/T 0.78 0.69 ∆T 23 21 kW 3.48 3.56 Amps 13.7 14.0 HI PR 224 241 LO PR 101 108
59 55.9 0.74 19 3.57 14.1 231 104 54.2 0.71 20 3.54 13.9 229 103 50.1 0.68 20 3.45 13.6 222 100
63 57.9 0.62 16 3.65 14.4 248 111 56.2 0.59 17 3.62 14.3 246 110 51.9 0.57 17 3.53 13.9 239 106
Airflow MBh S/T ∆T kW 2025 Amps HI PR LO PR MBh S/T ∆T kW 1800 Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 67.94 0.37 11 3.94 15.6 276 130 66.0 0.35 12 3.90 15.5 274 129 60.9 0.34 12 3.80 15.0 265 125
71 55.48 0.88 22 3.90 15.4 262 111 53.9 0.84 23 3.87 15.3 259 110 49.7 0.81 23 3.77 14.8 251 107
59 54.6 0.77 19 3.86 15.2 259 110 53.0 0.73 20 3.83 15.1 256 109 48.9 0.71 20 3.73 14.7 249 106 57.12 0.78 20 3.99 15.8 282 118 55.5 0.75 21 3.95 15.6 279 117 51.2 0.72 22 3.85 15.2 270 114
63 56.5 0.64 17 3.95 15.6 279 117 54.9 0.61 17 3.92 15.5 276 116 50.7 0.59 17 3.82 15.0 268 112 61.83 0.59 17 4.12 16.3 297 129 60.0 0.57 17 4.09 16.2 294 128 55.4 0.55 18 3.98 15.7 286 124
67 62.0 0.45 13 4.09 16.2 294 128 60.1 0.43 13 4.05 16.0 291 127 55.5 0.41 13 3.95 15.6 283 123
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
66.36 0.38 11 4.27 16.9 310 138 64.4 0.36 12 4.23 16.8 307 136 59.5 0.35 12 4.12 16.3 298 132
71 54.16 0.90 22 4.16 16.8 298 116 52.6 0.86 23 4.12 16.6 295 114 48.5 0.83 23 4.02 16.1 286 111
59 53.3 0.79 19 4.12 16.6 295 114 51.7 0.75 20 4.09 16.5 292 113 47.7 0.73 20 3.98 16.0 283 110 55.76 0.80 20 4.26 17.2 320 123 54.1 0.77 21 4.22 17.0 317 122 50.0 0.74 22 4.11 16.5 308 118
60.36 0.61 17 4.40 17.8 338 134 58.6 0.58 17 4.36 17.6 335 133 54.1 0.56 18 4.25 17.1 325 129
52.84 0.93 22 4.39 18.0 339 121 51.3 0.88 23 4.35 17.8 336 120 47.3 0.85 24 4.24 17.3 326 117
54.40 0.83 20 4.49 18.4 365 129 52.8 0.79 21 4.45 18.2 361 128 48.8 0.76 22 4.34 17.7 350 124
58.89 0.63 17 4.65 19.0 385 141 57.2 0.60 17 4.61 18.9 381 140 52.8 0.58 18 4.49 18.3 370 135
63.20 0.40 12 4.81 19.8 402 150 61.4 0.38 12 4.77 19.6 398 149 56.6 0.37 12 4.64 19.0 386 144
50.20 0.96 22 4.59 19.1 381 127 48.7 0.92 23 4.55 19.0 378 126 45.0 0.88 23 4.43 18.4 366 122
59 49.4 0.85 19 4.55 19.0 377 126 47.9 0.81 20 4.51 18.8 374 125 44.2 0.78 20 4.39 18.2 363 121
Shaded area reflects ACCA (TVA) conditions
64.78 0.39 12 4.56 18.5 353 143 62.9 0.37 12 4.52 18.3 349 142 58.1 0.36 12 4.40 17.8 339 137
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 55.2 60.5 52.0 53.9 59.0 0.66 0.46 0.82 0.68 0.47 17 13 19 17 13 4.22 4.36 4.35 4.45 4.61 17.0 17.6 17.8 18.2 18.9 317 335 336 361 381 122 133 120 128 140 53.6 58.7 50.4 52.3 57.3 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 4.18 4.33 4.31 4.41 4.57 16.9 17.4 17.6 18.1 18.7 314 331 332 357 377 120 132 119 127 138 49.5 54.2 46.6 48.3 52.9 0.61 0.42 0.75 0.63 0.43 18 13 20 18 13 4.07 4.21 4.20 4.30 4.45 16.4 16.9 17.1 17.5 18.1 304 321 322 347 366 117 128 115 123 134 51.68 0.86 20 4.70 19.6 410 135 50.2 0.82 21 4.65 19.4 406 134 46.3 0.79 21 4.53 18.9 394 130
63 51.2 0.71 16 4.65 19.4 406 134 49.7 0.67 17 4.61 19.2 402 133 45.8 0.65 17 4.49 18.7 390 129 55.94 0.65 17 4.86 20.3 433 148 54.3 0.62 17 4.82 20.1 429 146 50.1 0.60 18 4.69 19.5 416 142
67 56.1 0.49 12 4.82 20.1 429 146 54.4 0.47 13 4.77 19.9 425 145 50.2 0.45 13 4.65 19.3 412 140
105ºF
46.50 0.97 20 4.76 20.3 421 132 45.1 0.93 21 4.71 20.1 417 130 41.7 0.89 22 4.59 19.5 405 126
59 45.7 0.85 18 4.71 20.1 417 130 44.4 0.81 18 4.67 19.9 413 129 41.0 0.78 19 4.55 19.4 401 125 47.87 0.87 19 4.87 20.8 453 140 46.5 0.83 20 4.83 20.6 449 139 42.9 0.80 20 4.70 20.0 435 134
63 47.4 0.71 15 4.83 20.6 449 139 46.0 0.68 16 4.78 20.4 444 137 42.5 0.66 16 4.66 19.8 431 133 51.82 0.66 15 5.04 21.5 479 153 50.3 0.63 16 5.00 21.3 474 151 46.4 0.60 16 4.86 20.7 460 147
67 51.9 0.49 12 4.99 21.3 474 151 50.4 0.47 12 4.95 21.1 469 150 46.5 0.45 12 4.82 20.5 455 145 55.62 0.42 11 5.22 22.4 499 163 54.0 0.40 11 5.17 22.2 494 161 49.8 0.39 11 5.03 21.5 480 156
71 -
kW = Total system power Amps = outdoor unit amps (comp.+fan)
60.04 0.42 11 5.03 21.1 452 157 58.3 0.40 12 4.99 20.9 447 156 53.8 0.39 12 4.85 20.3 434 151
71 -
115ºF
Product Specifications
Expanded Cooling Data — ASXC160601B* / CA*F4961*6A*+TXV / MBVC2000**-1** HIgh Stage
SS-DSXC16
SS-DSXC16
www.goodmanmfg.com
62.80 0.85 24 3.87 15.3 270 125 61.0 0.81 25 3.84 15.2 268 123 56.3 0.78 26 3.74 14.8 260 120
MBh 58.82 59.96 S/T 0.97 0.94 ∆T 26 26 kW 3.66 3.75 Amps 14.5 14.8 HI PR 238 256 LO PR 107 114 MBh 57.1 58.2 S/T 0.93 0.89 ∆T 27 27 kW 3.63 3.72 Amps 14.3 14.7 HI PR 236 253 LO PR 106 113 MBh 52.7 53.7 S/T 0.89 0.86 ∆T 27 27 kW 3.54 3.62 Amps 13.9 14.3 HI PR 228 246 LO PR 103 110
1575
1800
2025
67 63.11 0.71 20 3.84 15.2 268 123 61.3 0.67 21 3.81 15.1 265 122 56.6 0.65 21 3.71 14.6 257 119
Airflow 59 63 MBh 57.81 59.07 S/T 0.93 0.87 ∆T 24 23 kW 3.63 3.72 2025 Amps 14.3 14.7 HI PR 236 253 LO PR 106 113 MBh 56.1 57.4 S/T 0.88 0.83 ∆T 25 24 kW 3.60 3.68 1800 Amps 14.2 14.6 HI PR 233 251 LO PR 105 112 MBh 51.8 52.9 S/T 0.85 0.80 ∆T 26 25 1575 kW 3.51 3.59 Amps 13.8 14.2 HI PR 226 243 LO PR 102 109 67.00 0.69 21 4.01 15.9 282 133 65.0 0.65 22 3.97 15.8 279 131 60.0 0.63 22 3.87 15.3 271 128
71 67.47 0.53 16 3.97 15.8 279 131 65.5 0.50 17 3.94 15.6 276 130 60.5 0.49 17 3.84 15.2 268 126 57.45 1.00 26 3.97 15.7 267 113 55.8 0.96 27 3.93 15.5 264 112 51.5 0.93 28 3.83 15.1 256 109
59 56.47 0.96 25 3.93 15.5 264 112 54.8 0.92 26 3.90 15.4 262 111 50.6 0.88 26 3.80 15.0 254 108 58.57 0.97 26 4.06 16.1 287 121 56.9 0.93 27 4.02 15.9 284 119 52.5 0.89 27 3.92 15.5 276 116
63 57.70 0.90 24 4.02 15.9 284 119 56.0 0.86 25 3.99 15.8 282 118 51.7 0.83 25 3.88 15.3 273 115 61.34 0.88 24 4.20 16.6 303 132 59.6 0.84 25 4.16 16.5 300 130 55.0 0.81 26 4.05 16.0 291 127
67 61.65 0.73 21 4.16 16.5 300 130 59.9 0.70 21 4.12 16.3 297 129 55.2 0.67 22 4.02 15.9 288 125
75ºF
IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
65.44 0.71 21 4.34 17.3 316 140 63.5 0.68 22 4.30 17.1 313 139 58.6 0.65 22 4.19 16.6 304 135
71 65.90 0.55 16 4.30 17.1 313 139 64.0 0.52 17 4.27 16.9 310 138 59.1 0.50 17 4.16 16.5 301 133 56.09 1.00 25 4.23 17.1 304 118 54.5 0.98 27 4.20 16.9 301 117 50.3 0.95 28 4.09 16.4 292 113
57.17 1.00 26 4.33 17.5 327 125 55.5 0.95 27 4.29 17.3 323 124 51.2 0.92 27 4.18 16.9 314 120
59.88 0.90 24 4.48 18.1 345 137 58.1 0.86 25 4.44 17.9 342 136 53.7 0.83 26 4.33 17.4 331 132
54.72 1.00 25 4.47 18.3 346 124 53.1 1.00 27 4.43 18.1 342 123 49.0 0.98 28 4.31 17.6 332 119
55.78 1.00 25 4.57 18.8 372 132 54.2 0.98 27 4.53 18.6 368 130 50.0 0.95 28 4.41 18.1 357 127
58.42 0.93 25 4.73 19.4 393 144 56.7 0.89 26 4.69 19.2 389 142 52.3 0.85 26 4.57 18.7 377 138
62.32 0.75 21 4.90 20.2 410 153 60.5 0.72 22 4.86 20.0 406 152 55.8 0.69 23 4.73 19.4 394 147
51.98 1.00 24 4.67 19.5 389 130 50.5 1.00 26 4.63 19.3 385 129 46.6 1.00 27 4.51 18.8 374 125
59 51.09 1.00 23 4.63 19.3 385 129 49.6 1.00 25 4.59 19.1 381 127 45.8 0.97 26 4.47 18.6 370 123
Shaded area reflects AHRI (TVA) conditions
63.88 0.73 21 4.64 18.8 360 146 62.0 0.70 22 4.60 18.6 356 144 57.2 0.67 22 4.48 18.1 346 140
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 55.12 56.33 60.18 64.33 53.78 54.95 58.71 62.76 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 25 24 21 16 24 24 21 17 4.20 4.29 4.44 4.60 4.43 4.53 4.69 4.86 16.9 17.3 17.9 18.6 18.1 18.6 19.2 20.0 301 323 342 356 342 368 389 406 117 124 136 144 123 130 142 152 53.5 54.7 58.4 62.5 52.2 53.4 57.0 60.9 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 26 25 21 17 26 25 22 17 4.16 4.26 4.40 4.56 4.39 4.49 4.65 4.81 16.8 17.2 17.8 18.5 18.0 18.4 19.0 19.8 298 320 338 353 339 365 385 402 116 123 134 143 121 129 141 150 49.4 50.5 53.9 57.6 48.2 49.2 52.6 56.2 0.91 0.85 0.69 0.52 0.93 0.88 0.71 0.53 26 25 22 17 26 25 22 18 4.05 4.15 4.29 4.44 4.28 4.38 4.53 4.69 16.3 16.7 17.3 17.9 17.4 17.9 18.5 19.2 289 311 328 342 329 354 374 390 112 119 130 139 118 125 137 146 52.99 1.00 24 4.78 20.0 419 138 51.4 1.00 26 4.74 19.8 414 137 47.5 0.98 27 4.61 19.2 402 133
63 52.20 1.00 24 4.74 19.8 414 137 50.7 0.94 24 4.70 19.6 410 135 46.8 0.91 25 4.57 19.1 398 131 55.50 0.96 24 4.95 20.7 442 151 53.9 0.92 25 4.90 20.5 438 149 49.7 0.89 26 4.77 19.9 425 145
67 55.77 0.81 20 4.90 20.5 438 149 54.2 0.77 21 4.86 20.3 433 148 50.0 0.74 22 4.73 19.7 420 143
105ºF
48.15 1.00 22 4.84 20.7 430 134 46.7 1.00 24 4.80 20.5 426 133 43.1 1.00 25 4.67 19.9 413 129
59 47.32 1.00 21 4.80 20.5 426 133 45.9 1.00 23 4.76 20.3 421 132 42.4 0.98 24 4.63 19.7 409 128 49.08 1.00 22 4.96 21.2 463 143 47.7 1.00 24 4.91 21.0 458 141 44.0 0.99 25 4.78 20.4 444 137
63 48.36 1.00 22 4.91 21.0 458 141 46.9 0.95 23 4.87 20.8 453 140 43.3 0.92 23 4.74 20.2 440 136 51.41 0.97 23 5.13 22.0 488 156 49.9 0.93 24 5.09 21.7 484 154 46.1 0.89 24 4.95 21.1 469 150
67 51.66 0.81 19 5.09 21.7 484 154 50.2 0.77 20 5.04 21.5 479 153 46.3 0.75 20 4.91 20.9 464 148 54.84 0.79 20 5.31 22.8 509 166 53.2 0.75 20 5.27 22.6 504 164 49.1 0.72 21 5.13 21.9 489 159
71 55.23 0.61 15 5.27 22.6 504 164 53.6 0.58 16 5.22 22.4 499 163 49.5 0.56 16 5.08 21.7 484 158
kW = Total system power Amps = outdoor unit amps (comp.+fan)
59.21 0.78 21 5.12 21.5 461 161 57.5 0.75 22 5.08 21.3 457 159 53.1 0.72 22 4.94 20.7 443 154
71 59.62 0.60 16 5.08 21.3 457 159 57.9 0.57 17 5.03 21.1 452 157 53.4 0.55 17 4.90 20.5 438 153
115ºF
Product Specifications
Expanded Cooling Data — ASXC160601B*/CA*F4961*6A*+TXV / MBVC2000**-1** High Stage (cont.)
23
Product Specifications
AHRI Performance Data Outdoor Unit
DSXC16 0241A*
Indoor Units Coils / Air Handlers Furnaces / Blowers AEPF183016C*+TXV CA*F3636*6C*+TXV MBE1200**-1B* CA*F3636*6C*+TXV MBVC1200**-1A* CA*F3636*6C*+TXV A*V80704B** CA*F3636*6C*+TXV A*VC80704BXA* CA*F3636*6C*+TXV G*VC90704CXA* CA*F3636*6C*+TXV G*V90704C** CA*F3636*6C*+TXV G*V90905D** CA*F3636*6C*+TXV G*V950453B** CA*F3636*6C*+TXV G*V950704C** CA*F3636*6C*+TXV G*VC950704CXA* CA*F3636*6C*+TXV G*VC90905DXA* CA*F3636*6C*+TXV G*VC950453BXA* CA*F3642*6C*+TXV A*VC80704BXA* CA*F3642*6C*+TXV G*V90704C** CA*F3642*6C*+TXV G*V90905D** CA*F3642*6C*+TXV G*V950453B** CA*F3642*6C*+TXV A*V80704B** CA*F3642*6C*+TXV G*V950704C** CA*F3642*6C*+TXV G*VC90704CXA* CA*F3642*6C*+TXV G*VC90905DXA* CA*F3642*6C*+TXV G*VC950453BXA* CA*F3642*6C*+TXV G*VC950704CXA* CHPF3636B6C*+TXV MBE1200**-1B* CHPF3636B6C*+TXV MBVC1200**-1A* CHPF3636B6C*+TXV A*V80704B** CHPF3636B6C*+TXV A*VC80704BXA* CHPF3636B6C*+TXV G*V950453B** CHPF3636B6C*+TXV G*V950704C** CHPF3636B6C*+TXV G*VC950453BXA* CHPF3636B6C*+TXV G*VC950704CXA* CHPF3642C6C*+TXV G*V950453B** CHPF3642C6C*+TXV G*V950704C** CHPF3642C6C*+TXV G*VC950453BXA* CHPF3642C6C*+TXV G*VC950704CXA* CHPF3743C6B*+TXV G*V950453B** CHPF3743C6B*+TXV G*V950704C** CHPF3743C6B*+TXV G*VC950453BXA* CHPF3743C6B*+TXV G*VC950704CXA* CHTF3636B6A*+TXV MBE1200**-1B* CHTF3636B6A*+TXV MBVC1200**-1A* CSCF3036N6B*+TXV G*V90905D** CSCF3036N6B*+TXV G*V950453B** CSCF3036N6B*+TXV G*V950704C** CSCF3036N6B*+TXV A*V80704B** CSCF3036N6B*+TXV G*VC90704CXA* CSCF3036N6B*+TXV G*VC90905DXA* CSCF3036N6B*+TXV G*VC950453BXA* CSCF3036N6B*+TXV G*VC950704CXA* CSCF3036N6B*+TXV A*VC80704BXA* CSCF3036N6B*+TXV G*V90704C** CSCF3642N6C*+TXV G*VC90905DXA* CSCF3642N6C*+TXV G*VC950453BXA* CSCF3642N6C*+TXV G*VC950704CXA* CSCF3642N6C*+TXV G*V950453B** CSCF3642N6C*+TXV G*V950704C** CSCF3642N6C*+TXV G*VC90704CXA* CSCF3642N6C*+TXV G*V90905D** CSCF3642N6C*+TXV A*V80704B** CSCF3642N6C*+TXV A*VC80704BXA* CSCF3642N6C*+TXV G*V90704C**
Total 23,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000
Cooling Capacity (BTU/h) Sensible SEER¹ 17,300 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 15.5 18,000 15.5 18,000 16.0 18,000 15.5 18,000 16.0 18,000 15.5 18,000 16.0 18,000 16.0 18,000 15.5 18,000 16.0 18,000 15.5 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0 18,000 16.0
EER² 12.5 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 12.5 13.0 12.5 13.0 13.0 13.0 13.0 12.5 12.5 12.5 12.5 12.5 12.5 13.0 12.5 13.0 12.5 13.0 13.0 12.5 13.0 12.5 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0
ARI # 3653913 3653914 3653915 3653916 3653917 3653922 3653918 3653919 3653920 3653921 3653925 3653923 3653924 3653927 3653928 3653929 3653930 3653926 3653931 3653932 3653933 3653934 3653935 3653936 3653937 3653938 3653939 3653940 3653941 3653942 3653943 3653944 3653945 3653946 3653947 3653948 3653950 3653951 3653952 3653953 3653954 3653958 3653959 3653960 3653955 3653961 3653962 3653963 3653964 3653956 3653957 3653972 3653973 3653974 3653969 3653970 3653971 3653968 3653965 3653966 3653967
See Notes on Page 29.
24
www.goodmanmfg.com
SS-DSXC16
Product Specifications
AHRI Ratings (cont.) Outdoor Unit
DSXC16 0361A*
Indoor Units Coils / Air Handlers Furnaces / Blowers AEPF313716A*+TXV AEPF426016C*+TXV CA*F3642*6C*+TXV MBE1600**-1B* CA*F3642*6C*+TXV MBVC1600**-1A* CA*F3642*6C*+TXV A*V80704B** CA*F3642*6C*+TXV G*VC90905DXA* CA*F3642*6C*+TXV G*VC950704CXA* CA*F3642*6C*+TXV G*V90704C** CA*F3642*6C*+TXV G*V90905D** CA*F3642*6C*+TXV G*VC951155DXA* CA*F3642*6C*+TXV A*VC80704BXA* CA*F3642*6C*+TXV G*V950704C** CA*F3642*6C*+TXV G*V951155D** CA*F3642*6C*+TXV G*VC90704CXA* CA*F3743*6A*+TXV MBE1600**-1B* CA*F3743*6A*+TXV MBVC1600**-1A* CA*F3743*6A*+TXV A*V80704B** CA*F3743*6A*+TXV A*VC80704BXA* CA*F3743*6A*+TXV G*V90704C** CA*F3743*6A*+TXV G*V90905D** CA*F3743*6A*+TXV G*V91155D** CA*F3743*6A*+TXV G*V950453B** CA*F3743*6A*+TXV G*VC950704CXA* CA*F3743*6A*+TXV G*VC950905DXA* CA*F3743*6A*+TXV G*VC951155DXA* CA*F3743*6A*+TXV G*V951155D** CA*F3743*6A*+TXV G*VC90704CXA* CA*F3743*6A*+TXV G*VC950453BXA* CA*F3743*6A*+TXV G*VC90905DXA* CA*F3743*6A*+TXV G*VC91155DXA* CA*F3743*6A*+TXV G*V950704C** CA*F3743*6A*+TXV G*V950905D** CA*F4860*6B*+TXV G*VC951155DXA* CA*F4860*6B*+TXV G*V90704C** CA*F4860*6B*+TXV G*V90905D** CA*F4860*6B*+TXV A*V80704B** CA*F4860*6B*+TXV A*VC80704BXA* CA*F4860*6B*+TXV G*VC950905DXA* CA*F4860*6B*+TXV G*V951155D** CA*F4860*6B*+TXV G*VC90704CXA* CA*F4860*6B*+TXV G*VC90905DXA* CA*F4860*6B*+TXV G*VC91155DXA* CA*F4860*6B*+TXV G*V91155D** CA*F4860*6B*+TXV G*V950453B** CA*F4860*6B*+TXV G*V950704C** CA*F4860*6B*+TXV G*V950905D** CA*F4860*6B*+TXV G*VC950453BXA* CA*F4860*6B*+TXV G*VC950704CXA* CHPF3642C6C*+TXV MBE1600**-1B* CHPF3642C6C*+TXV MBVC1600**-1A* CHPF3642C6C*+TXV G*VC951155DXA* CHPF3642C6C*+TXV A*V80704B** CHPF3642C6C*+TXV A*VC80704BXA* CHPF3642C6C*+TXV G*V950453B** CHPF3642C6C*+TXV G*V950704C** CHPF3642C6C*+TXV G*V950905D** CHPF3642C6C*+TXV G*V951155D** CHPF3642C6C*+TXV G*VC950453BXA* CHPF3642C6C*+TXV G*VC950704CXA* CHPF3642C6C*+TXV G*VC950905DXA* CHPF3642D6C*+TXV MBE2000**-1B* CHPF3642D6C*+TXV MBVC2000**-1A*
Total 35,000 36,000 34,000 34,000 34,000 34,600 34,600 34,600 34,600 34,600 34,000 34,600 34,600 34,600 35,000 35,000 34,000 34,000 34,600 34,600 34,600 34,000 34,600 34,600 34,600 34,600 34,600 34,000 34,600 34,600 34,600 34,600 34,600 35,000 35,000 34,600 34,600 35,000 34,600 35,000 35,000 35,000 35,000 34,600 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,000 34,000 34,000 34,600 34,600 34,600 34,000 34,600 34,600 35,000 35,000
Cooling Capacity (BTU/h) Sensible SEER¹ 24,900 16.0 25,600 16.0 24,100 15.5 24,100 15.5 24,100 15.5 24,600 15.5 24,600 16.0 24,600 15.5 24,600 15.5 24,600 16.0 24,100 15.5 24,600 16.0 24,600 16.0 24,600 15.5 24,900 16.0 24,900 16.0 24,100 16.0 24,100 16.0 24,600 15.5 24,600 15.5 24,600 15.5 24,100 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 15.5 24,100 16.0 24,600 15.5 24,600 15.5 24,600 16.0 24,600 16.0 24,600 16.0 24,900 16.0 24,900 16.0 24,600 16.0 24,600 16.0 24,900 16.0 24,600 16.0 24,900 16.0 24,900 16.0 24,900 15.5 24,900 15.5 24,600 16.0 24,900 16.0 24,900 16.0 24,600 16.0 24,900 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,100 15.5 24,100 15.5 24,100 15.5 24,600 16.0 24,600 16.0 24,600 16.0 24,100 15.5 24,600 16.0 24,600 16.0 24,900 16.0 24,900 16.0
EER² 12.8 12.8 12.0 12.0 12.0 12.0 12.3 12.0 12.0 12.3 12.0 12.3 12.3 12.0 12.5 12.5 12.5 12.5 12.2 12.2 12.2 12.5 12.5 12.5 12.5 12.5 12.2 12.5 12.2 12.2 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.2 12.2 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.0 12.0 12.0 12.0 12.5 12.5 12.0 12.0 12.5 12.8 12.8
ARI # 3653975 3653976 3653977 3653978 3653979 3653986 3653987 3653981 3653982 3653988 3653980 3653983 3653984 3653985 3653989 3653990 3653991 3653992 3653993 3653994 3653995 3653996 3654004 3654005 3654006 3653999 3654000 3654003 3654001 3654002 3653997 3653998 3654022 3654009 3654010 3654007 3654008 3654021 3654015 3654016 3654017 3654018 3654011 3654012 3654013 3654014 3654019 3654020 3654023 3654024 3654034 3654025 3654026 3654027 3654028 3654029 3654030 3654031 3654032 3654033 3654035 3654036
See Notes on Page 29.
SS-DSXC16
www.goodmanmfg.com
25
Product Specifications
AHRI Ratings (cont.) Outdoor Unit
DSXC16 0361A* (cont.)
Indoor Units Coils / Air Handlers Furnaces / Blowers CHPF3642D6C*+TXV G*V950905D** CHPF3642D6C*+TXV G*V951155D** CHPF3642D6C*+TXV G*VC950905DXA* CHPF3642D6C*+TXV G*VC951155DXA* CHPF3743C6B*+TXV MBE1600**-1B* CHPF3743C6B*+TXV MBVC1600**-1A* CHPF3743C6B*+TXV A*V80704B** CHPF3743C6B*+TXV A*VC80704BXA* CHPF3743C6B*+TXV G*V90905D** CHPF3743C6B*+TXV G*V950453B** CHPF3743C6B*+TXV G*V950704C** CHPF3743C6B*+TXV G*V950905D** CHPF3743C6B*+TXV G*V951155D** CHPF3743C6B*+TXV G*VC90905DXA* CHPF3743C6B*+TXV G*VC950905DXA* CHPF3743C6B*+TXV G*VC951155DXA* CHPF3743C6B*+TXV G*VC950453BXA* CHPF3743C6B*+TXV G*VC950704CXA* CHPF3743D6B*+TXV MBE2000**-1B* CHPF3743D6B*+TXV MBVC2000**-1A* CHPF3743D6B*+TXV A*V80704B** CHPF3743D6B*+TXV G*V951155D** CHPF3743D6B*+TXV G*VC950453BXA* CHPF3743D6B*+TXV G*VC950704CXA* CHPF3743D6B*+TXV A*VC80704BXA* CHPF3743D6B*+TXV G*V950453B** CHPF3743D6B*+TXV G*V950704C** CHPF3743D6B*+TXV G*V950905D** CHPF3743D6B*+TXV G*VC950905DXA* CHPF3743D6B*+TXV G*VC951155DXA* CHPF4860D6D*+TXV G*VC950453BXA* CHPF4860D6D*+TXV G*VC950704CXA* CHPF4860D6D*+TXV A*V80704B** CHPF4860D6D*+TXV G*V951155D** CHPF4860D6D*+TXV G*VC951155DXA* CHPF4860D6D*+TXV G*VC950905DXA* CHPF4860D6D*+TXV G*V950905D** CHPF4860D6D*+TXV A*VC80704BXA* CHPF4860D6D*+TXV G*V950453B** CHPF4860D6D*+TXV G*V950704C** CHTF3743C6A*+TXV MBE1600**-1B* CHTF3743C6A*+TXV MBVC1600**-1A* CSCF3642N6C*+TXV A*V80704B** CSCF3642N6C*+TXV A*V80905C** CSCF3642N6C*+TXV A*VC80704BXA* CSCF3642N6C*+TXV A*VC80905CXA* CSCF3642N6C*+TXV G*V950453B** CSCF3642N6C*+TXV G*VC950453BXA* CSCF4860N6C*+TXV A*V80704B** CSCF4860N6C*+TXV G*V951155D** CSCF4860N6C*+TXV A*VC80704BXA* CSCF4860N6C*+TXV G*V950453B** CSCF4860N6C*+TXV G*V950704C** CSCF4860N6C*+TXV G*V950905D** CSCF4860N6C*+TXV G*VC950704CXA* CSCF4860N6C*+TXV G*VC950905DXA* CSCF4860N6C*+TXV G*VC950453BXA* CSCF4860N6C*+TXV G*VC951155DXA* CT*F3636*6A*+TXV MBE1600**-1B* CT*F3636*6A*+TXV MBVC1600**-1A* CT*F3642*6A*+TXV MBE1600**-1B* CT*F3642*6A*+TXV MBVC1600**-1A*
Total 34,600 34,600 34,600 34,600 34,600 34,600 34,000 34,000 34,600 34,000 34,600 34,600 34,600 34,600 34,600 34,600 34,000 34,600 35,000 35,000 34,000 34,600 34,000 34,000 34,000 34,000 34,000 34,600 34,600 34,600 34,600 35,000 34,600 35,000 35,000 35,000 35,000 34,600 34,600 35,000 34,600 34,600 34,000 34,000 34,000 34,000 34,000 34,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 34,600 34,600 34,600 34,600
Cooling Capacity (BTU/h) Sensible SEER¹ 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,100 15.5 24,100 15.5 24,600 16.0 24,100 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,100 16.0 24,600 16.0 24,900 16.0 24,900 16.0 24,100 16.0 24,600 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,900 16.0 24,600 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,600 16.0 24,600 16.0 24,900 16.0 24,600 16.0 24,600 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,100 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,900 16.0 24,600 16.0 24,600 16.0 24,600 16.0 24,600 16.0
EER² 12.5 12.5 12.5 12.5 12.5 12.5 12.0 12.0 12.5 12.5 12.0 12.5 12.5 12.5 12.5 12.5 12.5 12.0 12.8 12.8 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.3 12.5 12.3 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5
ARI # 3654037 3654038 3654039 3654040 3654041 3654042 3654043 3654044 3654045 3654046 3654047 3654048 3654049 3654050 3654053 3654054 3654051 3654052 3654055 3654056 3654057 3654062 3654063 3654064 3654058 3654059 3654060 3654061 3654065 3654066 3654073 3654074 3654067 3654072 3654076 3654075 3654071 3654068 3654069 3654070 3654077 3654078 3654079 3654080 3654081 3654082 3654083 3654084 3654085 3654090 3654086 3654087 3654088 3654089 3654092 3654093 3654091 3654094 3654095 3654096 3654097 3654098
See Notes on Page 29.
26
www.goodmanmfg.com
SS-DSXC16
Product Specifications
AHRI Ratings (cont.) Outdoor Unit
DSXC16 0481A*
Indoor Units Coils / Air Handlers Furnaces / Blowers AEPF426016C*+TXV CA*F4860*6B*+TXV MBE1600**-1B* CA*F4860*6B*+TXV MBE2000**-1B* CA*F4860*6B*+TXV MBVC1600**-1A* CA*F4860*6B*+TXV MBVC2000**-1A* CA*F4860*6B*+TXV A*V80704B** CA*F4860*6B*+TXV G*VC950905DXA* CA*F4860*6B*+TXV G*VC951155DXA* CA*F4860*6B*+TXV G*V90905D** CA*F4860*6B*+TXV G*V91155D** CA*F4860*6B*+TXV G*V950905D** CA*F4860*6B*+TXV A*V80905C** CA*F4860*6B*+TXV A*VC80905CXA* CA*F4860*6B*+TXV G*VC90905DXA* CA*F4860*6B*+TXV G*VC91155DXA* CA*F4860*6B*+TXV G*V951155D** CA*F4961*6A*+TXV MBE1600**-1B* CA*F4961*6A*+TXV MBE2000**-1B* CA*F4961*6A*+TXV MBVC1600**-1A* CA*F4961*6A*+TXV MBVC2000**-1A* CA*F4961*6A*+TXV G*VC91155DXA* CA*F4961*6A*+TXV G*VC950704CXA* CA*F4961*6A*+TXV A*V80704B** CA*F4961*6A*+TXV G*V90704C** CA*F4961*6A*+TXV G*V90905D** CA*F4961*6A*+TXV G*V91155D** CA*F4961*6A*+TXV G*VC90905DXA* CA*F4961*6A*+TXV G*VC950905DXA* CA*F4961*6A*+TXV G*VC951155DXA* CA*F4961*6A*+TXV G*V950704C** CA*F4961*6A*+TXV G*V950905D** CA*F4961*6A*+TXV G*V951155D** CHPF4860D6D*+TXV MBE1600**-1B* CHPF4860D6D*+TXV MBE2000**-1B* CHPF4860D6D*+TXV MBVC1600**-1A* CHPF4860D6D*+TXV MBVC2000**-1A* CHPF4860D6D*+TXV A*V80704B** CHPF4860D6D*+TXV A*V80905C** CHPF4860D6D*+TXV A*VC80905CXA* CHPF4860D6D*+TXV G*V950704C** CHPF4860D6D*+TXV G*V950905D** CHPF4860D6D*+TXV G*V951155D** CHPF4860D6D*+TXV G*VC950704CXA* CHPF4860D6D*+TXV G*VC950905DXA* CHPF4860D6D*+TXV G*VC951155DXA* CHTF4860D6A*+TXV MBE2000**-1B* CHTF4860D6A*+TXV MBVC2000**-1A* CSCF4860N6C*+TXV A*V80704B** CSCF4860N6C*+TXV G*VC950704CXA* CSCF4860N6C*+TXV G*VC950905DXA* CSCF4860N6C*+TXV G*VC951155DXA* CSCF4860N6C*+TXV G*V950704C** CSCF4860N6C*+TXV G*V950905D** CSCF4860N6C*+TXV G*V951155D** CT*F4860*6A*+TXV MBE2000**-1B* CT*F4860*6A*+TXV MBVC2000**-1A*
Total 46,000 46,000 47,000 46,000 47,000 45,500 47,000 47,000 45,500 45,500 47,000 47,000 47,000 45,500 45,500 47,000 46,000 47,000 46,000 47,000 45,500 46,500 46,000 45,500 45,500 45,500 45,500 47,000 47,000 46,500 47,000 47,000 46,000 47,000 46,000 47,000 45,500 45,500 45,500 46,000 47,000 47,000 46,000 47,000 47,000 47,000 47,000 45,500 45,500 46,000 46,000 45,500 46,000 46,000 47,000 47,000
Cooling Capacity (BTU/h) Sensible SEER¹ 35,000 15.5 35,000 15.0 35,700 16.0 35,000 15.0 35,700 16.0 34,600 15.0 35,700 16.0 35,700 16.0 34,600 15.0 34,600 15.5 35,700 16.0 35,700 16.0 35,700 16.0 34,600 15.0 34,600 15.5 35,700 16.0 35,000 15.0 35,700 16.0 35,000 15.0 35,700 16.0 34,600 15.5 35,300 15.0 35,000 15.5 34,600 15.0 34,600 15.5 34,600 15.5 34,600 15.5 35,700 16.0 35,700 16.0 35,300 15.0 35,700 16.0 35,700 16.0 35,000 15.0 35,700 16.0 35,000 15.0 35,700 16.0 34,600 15.5 34,600 15.5 34,600 15.5 35,000 15.5 35,700 16.0 35,700 16.0 35,000 15.5 35,700 16.0 35,700 16.0 35,700 16.0 35,700 16.0 34,600 15.5 34,600 15.0 35,000 16.0 35,000 16.0 34,600 15.0 35,000 16.0 35,000 16.0 35,700 16.0 35,700 16.0
EER² 12.0 12.0 12.5 12.0 12.5 12.0 12.3 12.3 11.5 11.5 12.3 12.3 12.3 11.5 11.5 12.3 12.0 12.5 12.0 12.5 12.0 12.0 12.2 11.5 12.0 12.0 12.0 12.5 12.5 12.0 12.5 12.5 12.0 12.5 12.0 12.5 12.0 12.0 12.0 12.0 12.3 12.3 12.0 12.3 12.3 12.5 12.5 12.0 12.0 12.5 12.5 12.0 12.5 12.5 12.5 12.5
ARI # 3654099 3654100 3654101 3654102 3654103 3654104 3654113 3654114 3654107 3654108 3654109 3654105 3654106 3654111 3654112 3654110 3654115 3654116 3654117 3654118 3654127 3654128 3654119 3654120 3654121 3654122 3654126 3654129 3654130 3654123 3654124 3654125 3654131 3654132 3654133 3654134 3654135 3654136 3654137 3654138 3654139 3654140 3654141 3654142 3654143 3654144 3654145 3654146 3654150 3654151 3654152 3654147 3654148 3654149 3654153 3654154
See Notes on Page 29.
SS-DSXC16
www.goodmanmfg.com
27
Product Specifications
AHRI Ratings (cont.) Outdoor Unit
DSXC16 0601A*
DSXC16 0601B*
Indoor Units Coils / Air Handlers Furnaces / Blowers AEPF426016C*+TXV CA*F4860*6B*+TXV MBE2000**-1B* CA*F4860*6B*+TXV MBVC2000**-1A* CA*F4860*6B*+TXV G*V90905D** CA*F4860*6B*+TXV G*V91155D** CA*F4860*6B*+TXV G*V950905D** CA*F4860*6B*+TXV G*V951155D** CA*F4860*6B*+TXV G*VC90905DXA* CA*F4860*6B*+TXV G*VC91155DXA* CA*F4860*6B*+TXV G*VC950905DXA* CA*F4860*6B*+TXV G*VC951155DXA* CA*F4961*6A*+TXV MBE2000**-1B* CA*F4961*6A*+TXV MBVC2000**-1A* CA*F4961*6A*+TXV G*V951155D** CA*F4961*6A*+TXV G*VC90905DXA* CA*F4961*6A*+TXV G*VC951155DXA* CA*F4961*6A*+TXV G*VC91155DXA* CA*F4961*6A*+TXV G*VC950905DXA* CA*F4961*6A*+TXV G*V90905D** CA*F4961*6A*+TXV G*V91155D** CA*F4961*6A*+TXV G*V950905D** CHPF4860D6D*+TXV MBE2000**-1B* CHPF4860D6D*+TXV MBVC2000**-1A* CHPF4860D6D*+TXV G*V950905D** CHPF4860D6D*+TXV G*V951155D** CHPF4860D6D*+TXV G*VC950905DXA* CHPF4860D6D*+TXV G*VC951155DXA* CHTF4860D6A*+TXV MBE2000**-1B* CHTF4860D6A*+TXV MBVC2000**-1A* CSCF4860N6C*+TXV G*V950905D** CSCF4860N6C*+TXV G*V951155D** CSCF4860N6C*+TXV G*VC950905DXA* CSCF4860N6C*+TXV G*VC951155DXA* CT*F4860*6A*+TXV MBE2000**-1B* CT*F4860*6A*+TXV MBVC2000**-1A* AEPF426016C*+TXV CA*F4860*6B*+TXV MBE2000**-1B* CA*F4860*6B*+TXV MBVC2000**-1A* CA*F4860*6B*+TXV A*VC90905DXA* CA*F4860*6B*+TXV G*V91155D** CA*F4860*6B*+TXV G*V951155D** CA*F4860*6B*+TXV G*VC950905DXA* CA*F4860*6B*+TXV G*VC90905DXA* CA*F4860*6B*+TXV A*VC80905CXA* CA*F4860*6B*+TXV A*VC951155DXA* CA*F4860*6B*+TXV A*V90905D** CA*F4860*6B*+TXV A*V91155D** CA*F4860*6B*+TXV G*V90905D** CA*F4860*6B*+TXV A*VC950905DXA* CA*F4860*6B*+TXV G*VC91155DXA* CA*F4860*6B*+TXV G*VC951155DXA* CA*F4860*6B*+TXV G*V950905D** CA*F4860*6B*+TXV A*V80905C** CA*F4860*6B*+TXV A*V81155C** CA*F4860*6B*+TXV A*VC81155CXA* CA*F4961*6A*+TXV MBE2000**-1B* CA*F4961*6A*+TXV MBVC2000**-1A* CA*F4961*6A*+TXV A*V81155C** CA*F4961*6A*+TXV G*E81155C** CA*F4961*6A*+TXV G*V91155D**
Total 57,000 57,000 57,000 56,500 57,000 57,500 57,500 56,500 57,000 57,500 57,500 57,000 57,000 57,500 56,500 57,500 57,000 57,500 56,500 57,000 57,500 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 56,000 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 57,000 57,000 56,000 56,000 56,000
Cooling Capacity (BTU/h) Sensible SEER¹ 43,300 15.5 43,300 16.0 43,300 16.0 42,900 15.0 43,300 15.0 43,700 15.5 43,700 15.5 42,900 15.0 43,300 15.0 43,700 15.5 43,700 15.5 43,300 16.0 43,300 16.0 43,700 15.5 42,900 15.5 43,700 15.5 43,300 15.0 43,700 15.5 42,900 15.5 43,300 15.0 43,700 15.5 43,300 16.0 43,300 16.0 43,300 15.5 43,300 15.5 43,300 15.5 43,300 15.5 43,300 16.0 43,300 16.0 43,300 15.5 43,300 15.5 43,300 15.5 43,300 15.5 43,300 16.0 43,300 16.0 42,180 15.5 41,440 15.5 41,070 15.5 41,070 15.5 41,070 15 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 41,070 15.5 42,180 16 42,180 16 41,440 15.5 41,440 15 41,440 15
EER² 11.5 12.0 12.0 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 12.0 12.0 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 12.0 12.0 12.5 11.5 12.5 11.5 12.0 12.0 11.5 11.5 11.5 11.5 12.0 12.0 12.3 12.3 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12.3 12.3 12 11.5 12
ARI # 3654155 3654156 3654157 3654158 3654159 3654160 3654161 3654162 3654163 3654164 3654165 3654166 3654167 3654171 3654172 3654175 3654173 3654174 3654168 3654169 3654170 3654176 3654177 3654178 3654179 3654180 3654181 3654182 3654183 3654184 3654185 3654186 3654187 3654188 3654189 3798897 3798898 3798899 3798851 3798872 3798878 3798889 3798884 3798843 3798859 3798835 3798839 3798869 3798855 3798887 3798893 3798874 3798827 3798831 3798847 3798900 3798901 3798832 3798865 3798873
See Notes on Page 29.
28
www.goodmanmfg.com
SS-DSXC16
Product Specifications
AHRI Ratings (cont.) Outdoor Unit
DSXC16 0601B* (cont.)
Indoor Units Coils / Air Handlers Furnaces / Blowers CA*F4961*6A*+TXV G*V950905D** CA*F4961*6A*+TXV A*VC951155DXA* CA*F4961*6A*+TXV G*E80905C** CA*F4961*6A*+TXV G*VC950905DXA* CA*F4961*6A*+TXV G*VC951155DXA* CA*F4961*6A*+TXV A*VC80905CXA* CA*F4961*6A*+TXV A*VC90905DXA* CA*F4961*6A*+TXV G*VC90905DXA* CA*F4961*6A*+TXV G*VC91155DXA* CA*F4961*6A*+TXV A*V80905C** CA*F4961*6A*+TXV A*V91155D** CA*F4961*6A*+TXV G*V90905D** CA*F4961*6A*+TXV G*V951155D** CA*F4961*6A*+TXV A*VC81155CXA* CA*F4961*6A*+TXV A*VC950905DXA* CA*F4961*6A*+TXV A*V90905D** CHPF4860D6D*+TXV MBE2000**-1B* CHPF4860D6D*+TXV MBVC2000**-1A* CHPF4860D6D*+TXV A*V80905C** CHPF4860D6D*+TXV A*V81155C** CHPF4860D6D*+TXV A*VC80905CXA* CHPF4860D6D*+TXV G*V90905D** CHPF4860D6D*+TXV G*VC81155CXA* CHPF4860D6D*+TXV G*V951155D** CHPF4860D6D*+TXV A*V91155D** CHPF4860D6D*+TXV G*V81155C** CHPF4860D6D*+TXV G*V950905D** CHPF4860D6D*+TXV A*VC81155CXA* CHPF4860D6D*+TXV G*E80905C** CHPF4860D6D*+TXV A*V90905D** CHPF4860D6D*+TXV A*VC950905DXA* CHPF4860D6D*+TXV A*VC951155DXA* CHPF4860D6D*+TXV A*VC90905DXA* CHPF4860D6D*+TXV G*E81155C** CHPF4860D6D*+TXV G*V80905C** CHPF4860D6D*+TXV G*VC950905DXA* CHPF4860D6D*+TXV G*VC90905DXA* CHPF4860D6D*+TXV G*VC80905CXA* CHPF4860D6D*+TXV G*VC951155DXA* CHTF4860D6A*+TXV MBE2000**-1B* CHTF4860D6A*+TXV MBVC2000**-1A* CSCF4860N6C*+TXV G*VC951155DXA* CSCF4860N6C*+TXV A*V80905C** CSCF4860N6C*+TXV A*VC90905DXA* CSCF4860N6C*+TXV A*VC950905DXA* CSCF4860N6C*+TXV A*VC80905CXA* CSCF4860N6C*+TXV G*V951155D** CSCF4860N6C*+TXV A*V90905D** CSCF4860N6C*+TXV A*VC951155DXA* CSCF4860N6C*+TXV A*VC81155CXA* CSCF4860N6C*+TXV A*V81155C** CSCF4860N6C*+TXV A*V91155D** CSCF4860N6C*+TXV G*VC950905DXA* CSCF4860N6C*+TXV G*V950905D** CT*F4860*6A*+TXV MBE2000**-1B* CT*F4860*6A*+TXV MBVC2000**-1A*
Total 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 57,000 57,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 57,000 57,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 56,000 57,000 57,000
Cooling Capacity (BTU/h) Sensible SEER¹ 41,440 15.5 41,440 15.5 41,440 15 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 42,180 15.5 42,180 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 16 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 42,180 16 42,180 16 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 41,440 15.5 42,180 16 42,180 16
EER² 12.3 12 11.5 12.3 12 12.3 12.3 12.3 12 12.3 12 12.3 12 12 12.3 12.3 12.3 12.3 12.3 12 12.3 12.3 12 12 12 12 12.3 12 11.5 12.3 12.3 12 12.3 11.5 12.3 12.3 12.3 12.3 12 12.3 12.3 12 12.3 12.3 12.3 12.3 12 12.3 12 12 12 12 12.3 12.3 12.3 12.3
ARI # 3798875 3798860 3798863 3798890 3798894 3798844 3798852 3798885 3798888 3798828 3798840 3798870 3798879 3798848 3798856 3798836 3798902 3798903 3798829 3798833 3798845 3798871 3798883 3798880 3798841 3798868 3798876 3798849 3798864 3798837 3798857 3798861 3798853 3798866 3798867 3798891 3798886 3798882 3798895 3798904 3798905 3798896 3798830 3798854 3798858 3798846 3798881 3798838 3798862 3798850 3798834 3798842 3798892 3798877 3798906 3798907
¹ Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F ² Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F Notes: • Always check the S&R plate for electrical data on the UNit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay
SS-DSXC16
www.goodmanmfg.com
29
Product Specifications
Dimensions
Model
30
www.goodmanmfg.com
Dimensions (")
DSXC160241A
29 x 29 x 38¼
DSXC160361A
29 x 29 x 38¼
DSXC160481A
35½ x 35½ x 38¼
DSXC160601A
35½ x 35½ x 38¼
DSXC160601B
35½ x 35½ x 38¼
SS-DSXC16
R
COMP
C
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
K6
CCH
WARNING
2
1 5
SC
RES
FROM OUTDOOR UNIT
FROM OUTDOOR UNIT
L2
L1
RUN
E8
L1
L2
R
C
E17
START RLY
START
CAP COM
E5
E10
HERM
E11
E13
L2 OUT
RELAY
CCH E21
RELAY
E16
RELAY
Y2
Y2
C R
R
C
E14 HIGH
INDOOR POWER SUPPLY 24 VAC
FAN RUN
R 2 1
2 1
C R
C
E24
LPCO
E26
OAT
HPCO
E28
E1
E47 OCT
FUSE
C R 1 2
E2
HIGH VOLTAGE FIELD
HIGH VOLTAGE LOW VOLTAGE
WIRING CODE FACTORY WIRI NG
E25
1
2
R
C
W1
Y1
Y2
L
O
RELAY
CONTROL BOX
0140R00138 REV A
UC BOARD
TO INDOOR COMMUNICATING PCB
INDOOR POWER SUPPLY 24 VAC
E23
RELAY
RVS
E22
COMMUNICATING INDOOR T-STAT
W1 C R
W1
Y1
L (OPTIONAL)
L
Y1
O
O
LEGACY INDOOR T-STAT
COM
START
E29
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
SR
OPTIONAL HARD START
HERM
COM
FAN
Wiring Diagram
ND.
S
C
C
Y2
AUX
CS
MAIN
COMP
R
R
SR 1
5 2
RD(LOW )
RUN CAPACITOR
BR
HERM
BK (HIGH)
FAN
IO
C
C
K2
S
S
OPTIONAL HARD START
SC
HERM C CAP COM
PU
HIGH K4
CAP LOW
AUX
LPC
FAN MOTOR
L1
L2
PSC FAN MOTOR K3
www.goodmanmfg.com UC CONTROL
MAIN
HPC
6
E14
3
4
TO uP
SS-DSXC16 1
O L Y2 Y1 W1 C R 2 1
COLOR CODE BK --------------- BLACK BL --------------- BLUE BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL/PK ---------- YELLOW/PINK STRIPE
Product Specifications
31
Product Specifications
Accessories Model
Description
DSXC16 024
DSXC16 036
DSXC16 048
DSXC16 060
ABK-20
Anchor Bracket Kit^
X
X
X
X
ASC-01
Anti-Short Cycle Kit
X
X
X
X
B1141643¹
24V Transformer
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CSR-U-1
Hard-start Kit
CSR-U-2
Hard-start Kit
Maximum number installed at the same time is limited. See table below.
CSR-U-3
Hard-start Kit
FSK01A²
Freeze Protection Kit
LSK02A
Liquid Line Solenoid Valve
OT18-60A³
Outdoor Thermostat/Lockout Thermostat
TX2N4⁴
TXV Kit
TX3N4⁴
TXV Kit
TX5N4
TXV Kit
^ ¹ ² ³ ⁴
Maximum number installed at the same time is limited. See separate table.
X X
Contains 20 brackets; four brackets needed to anchor unit to pad This component is included in the CTK01AA communicating thermostat kit. Installed on indoor coil Available in 24V legacy mode only. This feature is integrated in the communicating mode. Condensing units and heat pumps with reciprocating compressors require the use of startassist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.
Model B1141643¹ CSR-U-1 CSR-U-2 CSR-U-3 FSK01A 2 LSK02A OT18-60A 3 Model B1141643¹ CSR-U-1 CSR-U-2 CSR-U-3 FSK01A 2 LSK02A OT18-60A 3
Description 24V Transformer Hard-start Kit Hard-start Kit Hard-start Kit Freeze Protection Kit Liquid Line Solenoid Valve Outdoor Thermostat/Lockout Thermostat Description 24V Transformer Hard-start Kit Hard-start Kit Hard-start Kit Freeze Protection Kit Liquid Line Solenoid Valve Outdoor Thermostat/Lockout Thermostat
DSXC16 024
DSXC16 024
DSXC16 024
DSXC16 024 X
X
DSXC16 024 X X
X
X X
X
X
X X X
X X
DSXC16 036
DSXC16 036
DSXC16 036 X
X X X
X X
X DSXC16 036
DSXC16 036
X
X X
X X
X X
¹ This component is included in the CTK01AA communicating thermostat kit. ² Installed on indoor coil ³ Available in 24V legacy mode only. This feature is integrated in the communicating mode.
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
32
www.goodmanmfg.com
SS-DSXC16