MBVC Variable-Speed, ComfortNet™Compatible Modular Blowers Cooling Capacity: 18,000 - 60,000 BTU/h
Standard Features
• Compatible with the ComfortNet Communication System family of products • Variable-speed ECM blower motor • Auto configuration of the airflow and tonnage in communicating mode • CFM indicator • Maximum four low-voltage wires required for operation in communicating mode • Built-in dehumidify feature • Diagnostic indicator lights • Storage of six prior fault codes • Programmable heat strip settings • Color-coded terminal strip for noncommunicating set-up • Cooling and heat pump applications • AHRI Certified • ETL Listed
Cabinet Features
• Painted, galvanized steel cabinet • Blower section usable as an electric furnace • Foil-faced insulation is glued in place and covers the entire blower case, reducing sound and cabinet condensation • Bottom flanges formed inward for additional strength, and to provide mounting surface for cased-coil section
* Complete warranty details available from your local dealer or at www. goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.
SS-GMBVC
www.goodmanmfg.com
11/09
Product Specifications
Nomenclature MB 1,2
VC 3,4
12 5,6
00 7,8
A 9
Design Series MB Modular Blower
1 11
Electrical 1 208-230/60/1
Motor Speed V Variable Speed C ComfortNet™ Compatible
Revisions A First Series Circuit Breaker A No Circuit Breaker B Circuit Breaker
Airflow Delivered 08 800 CFM 12 1200 CFM 16 1600 CFM 20 2000 CFM
2
A 10
Factory-installed Electric Heat 00 No Heat
www.goodmanmfg.com
SS-GMBVC
Product Specifications
Specifications Blower Dimensions Motor HP Diameter Width
CFM @ 0.3” ESP (High to Low)
VoltagePhase
MCA*
MOP*
MBVC1200AA-1
1,200 to 600
208/230-1
4.3
15
10”
8”
½
73
MBVC1600AA-1
1,600 to 1,000
208/230-1
6.3
15
10”
8”
¾
83
MBVC2000AA-1
2,000 to 1,200
208/230-1
5.8
15
11”
10”
¾
95
Model
Ship Weight (lbs)
* Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for these specifications with approved accessory heaters installed.
Heat Kit Selection MBVC1200 AA-1A*
MBVC1600 AA-1A*
MBVC2000 AA-1A*
HKR-03*
X
X
X
HKR-05*/-05C*
X
X
X
HKR-06*
X
X
X
HKR-08*/-08C*
X
X
X
HKR-10*/-10C*
X
X
X
HKR-15C*
X
X
X
HKR-20C*
X
X Allowable combinations * Indicates revision level that may or may not be designated C Indicates Circuit Breaker option
Single Point Kit ** Model SPW-01
HKR-15C
HKR-20C
HKR-21C
X
X
X
** Must be installed along with any of the above compatible heat kits. This kit will fit any MBVC blower as long as a compatible heat kit is installed in the unit.
SS-GMBVC
www.goodmanmfg.com
3
Product Specifications Cooling / HP Airflow S1
S2
Speed Tap
MBVC1200 Airflow (SCFM)
MBVC1600 Airflow (SCFM)
MBVC2000 Airflow (SCFM)
off on off on
off off on on
A B C D
600 800 1000 1200
1000 1200 1400 1600
1200 1600 1800 2000
Cooling / HP / Aux Trim S3 S4 Trim Value off off 0
S5 off
Cooling Profile S6 off
A
on off on
on off on
off on on
B C D
off on on
10% -10% 0
Heater Kit kW Airflow S9
S10
S11
Heater KW
MBVC1200 Airflow (SCFM)
MBVC1600 Airflow (SCFM)
MBVC2000 Airflow (SCFM)
off off off off on on on on
off off on on off off on on
off on off on off on off on
21 20 15 10 8 6 5 3
NA NA 1400 1000 740 635 600 600
NA NA 1500 1000 1000 800 800 800
NA 2000 1500 1200 1000 800 800 800
MBVC Blower Performance Data — Dipswitch Summary Dipswitch # S1 - S2* S3 - S4* S5 - S6* S7* S8 S9 - S11
Function Cooling / HP Airflow A/B/C/D Cooling / HP / Aux Trim (-10%, 0, +10%) Cooling Profile A,B,C,D Dehum (on/off) Unused Heater Kit Kw
Default Setting Airflow D No Trim Profile 1 Off On Off/Off/Off
* Valid only if the system is wired in legacy mode. If system is wired in the 4-wire communicating mode, these functions are selected via the user menu in the CTK01AA T-STAT.
4
www.goodmanmfg.com
SS-GMBVC
Product Specifications
Dimensions Side and Front Views D 3 1/4
5 C1/8
(3) KNOCKOUTS 1.125 1.375 1.750 .875 KNOCKOUT (2 PLACES)
H
5 6 1/2
20"
W
Dimensions
Model
Width
Depth
Height
17½”
21”
26”
MBVC1600AA-1
21”
21”
30”
MBVC2000AA-1
24½”
21”
30”
MBVC1200AA-1
Top View 11.029 11”
13 88.840 /16” 3 10.159 10 /16”
13.178
11¼” 11.209
11.209 11¼” 20.021 201/16”
16.500 16 ½”
SMALL 17½”
SS-GMBVC
23.464 23 ½”
21” MEDIUM
www.goodmanmfg.com
24½” LARGE
5
PWIRING roduct Specifications DIAGRAMS
THERMOSTATS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring Diagrams
R
Typical Two-Stage Cool, Two-Stage Heat Thermostat Y2
C G
1
2
R C G
Y1 W1 W2
W1 W2 Y1
Y2
Y1
Y2
O
DEHUM
Modular Blower Integrated Control Module
* C
R
NEU HOT
Remote Condensing Unit (Two-Stage AC)
Dehumidistat [Optional]
Typical Two-Stage Cooling with Two-Stage Heating
O
R C
Y1
G EMR
1
2
R C G
Typical Two-Stage Cool, Two-Stage Heat Heat Pump Thermostat
Y2 W2
W1 W2 Y1
Y2
O
W1
Y2
O
DEHUM
Modular Blower Integrated Control Module
* C
R
Y1
Remote Condensing Unit (Two-Stage HP)
NEU HOT
Dehumidistat [Optional]
Typcial Two-Stage Heat Pump Heating and Auxiliary/Emergency Heating
Typical Two Stage Heat Pump heating and Auxiliary/Emergency Heating Wiring is subject to change. Always Wiring is subject to refer to the wiring diagram or the unit for the most up-to-date wiring.
6
⚠
change. Always refer theDisconnect wiring diagram the servicing unit for ortheinstalling most up-to-date wiring. High to Voltage: all poweron before this unit. Multiple power Warning sources may be present. Failure to do so may cause property damage, personal injury, or death.
www.goodmanmfg.com
⚡
7
SS-GMBVC
Product Specifications
WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring Diagrams (cont.)
FL
PU BL
BK
3
WH BK
RD
5
M2
M1
R
6
RD
BK
8
PU
M2
BL M3
RD
M1
M4
BL
M2
R1
5
M4
M2
RD
R2
BR
BK
BK
BK RD
RD
WH
6
RD
PLM
BL BK
3
BL
1
4 5
M1
YL
RD
M4
M5
M7
M6
M8
R1
6
3
BL
M3
M2
2
PU
BK R D
RD
R2
BK
BK
RD
BL
4
BR
5 6
WH
7 7
BK RD
YL
7
8
BK
8
9
RD
YL
9
BL BK
8
RD
9 L1
YL
H TR4 TL
1 2
YL
BK M1
4
M3
H TR1 TL
H TR3 TL
FL
P LM BK
RD
YL
3
WH
7
BK
2
PU BL
BK
RD
HT R3 TL
1
RD
4
M1
R
BK
BK
2
HT R2 TL
FL
PLM
1
RD
FL
9
L2 L1
ONE (1) ELEMENT ROWS
L2
L1
TWO (2) ELEMENT ROWS
L2
L1
L2
THREE (3) ELEMENT ROWS
L1
L2
L1
L2
FOUR (4) ELEMENT ROWS
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROW S INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
6
6 5 4
5 4 7 8 9
SEE NOTE 7
WH BL
GN DISCONNECT
BL
BK BR
BL
RD
TR
TH
4 CIRCUIT HEATER CONNECTOR
FUSE
CFM LED
24 V 3A
SEE NOTE 5
ELEC HEAT AF
DELAY
DEHUM UNUSED
1
O Y2
2
DIP SWITCHES
W2
LEARN
W1
BIAS TERM
STATUS LED
BIAS
4
G C
RX LED
R
SEE NOTE 6
2
1 TWO-STAGE INTEGRATED CONTROL MODULE
CIRCULATOR BLOWER GND
3 2 1
ECM MOTOR HARNESS
TH 24 VAC
W1 (1)
W1
HEAT SEQUENCER R1
W2 (2)
W2 Y1 Y2
L2 40 VA TRANSFORMER
HEAT SEQUENCER R2
+VDC (1) TO MICRO
G
RX (2)
INDOOR AIR CIRCULATOR BLWR
TX (3)
O
4
BL GY BK RD
24V THERMOSTAT CONNECTIONS
Y1
3
FUSE 3 A R
GND
208/230 VAC
L1
DEHUM 24 V THERMOSTAT CONNECTIONS
ADJUST
DIAGNOSTIC LED
COOL
R D
INDOOR AIR CIRCULATOR BLWR
COM
-
B K
7 8 9
COM
BK
Warning
1
24 VAC
1 2 3 4 5
GN BK
DEHUM C
NOTES:
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE BLOWER MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N THERMOSTAT INPUTS). 6. BIAS AND TERM DIPSWITCHES MUST BE IN "ON" POSITION. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.
TR COM
RD
1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
GND (4)
⚠
1
L2
GND
GND
RD
208 VAC
1
3
230 VAC RD
3
3
RD
2
2
4
2
L1
40 VA TRANSFORMER, SEE NOTE 1
PL1 PL2
INTEGRATED CONTROL MODULE
GY GRAY RD RED YL YELLOW OR ORANGE VT VIOLET GN GREEN
GND
LOW VOLTAGE (24V)
COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE
LOW VOLTAGE FIELD HI VOLTAGE (230V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL
BK BLACK
⚡
BK
RD
BK
EQUIPMENT GND
Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.
HTR1 TL
H TR2 TL
FL HT R1 TL
FL
PLM
BK
FL
HTR2 TL
FL
HTR1 TL
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
FL
FL
FIELD GND FIELD SPLICE RESISTER
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.
OVERCURRENT PROT. DEVICE PLUG CONNECTION
0140A00039 REV. A
8
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
SS-GMBVC
www.goodmanmfg.com
7
Product Specifications
Notes
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
8
www.goodmanmfg.com
SS-GMBVC