Retail Portfolio

Page 1



ARCHITECT OF RECORD

DAVID A. UDKOW ARCHITECT 11881 NORTH 113 WAY SCOTTSDALE, AZ 85259 CONTACT: DAVID A UKDOW EMAIL: DAVIDAUDKOW@COX.NET P: 480-614-3385 F: 480-614-0209

MEP ENGINEER AEDIFICA 796 MERCUS COURT FENTON, MISSOURI 63026

OWNER'S REPRESENTATIVE O'NEIL LANGAN 15 WEST 37TH STREET 15TH FLOOR NEW YORK, NY 10018 CONTACT: STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 x 231

NORTH

TH

CONTACT: ALPESH CHAVADA, PE, SE MANAGER OF STRUCTURAL ENGINEERING EMAIL: ACHAVDA@OSBORN-ENG.COM P: 614-556-4272

AREA OF WORK TENANT SPACE 2120 #2 (1400 SQ FT)

2120 SOUTH BLVD, CHARLOTTE, NC

R

OSBORNE ENGINEERING 990 WEST 3RD AVE - SUITE 200 COLUMBUS, OHIO 43212

2

AREA PLAN

1

SCALE: N.T.S.

1. SCOPE OF WORK: THIS IS A PERMIT APPLICATION FOR INTERIOR IMPROVEMENTS FOR A NEW RETAIL STORE. THE PROJECT INCLUDES WORK ON THE GROUND FLOOR OF AN EXISTING BUILDING. WORK INCLUDES ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING WORK. NO CHANGE TO EXISTING USE, EGRESS, OR OCCUPANCY. FIRE ALARM AND SPRINKLER TO BE FILED UNDER DEFERRED SUBMITTAL. 2. GOVERNING CODES: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO THE REQUIREMENTS OF THE FOLLOWING (INCLUDING AMENDMENTS), AND ANY OTHER FEDERAL, STATE AND LOCAL CODES, LAWS AND ORDINANCES THAT APPLY: 2018 N.C. BUILDING CODE 2018 N.C. EXISTING BUILDING CODE 2018 N.C. ENERGY CONSERVATION CODE 2018 N.C. FIRE PREVENTION CODE 2018 N.C. MECHANICAL CODE 2018 N.C. PLUMBING CODE 2018 N.C. FUEL GAS CODE 2017 NATIONAL ELECTRIC CODE ANSI A117.1, 2009 3. CONSTRUCTION SERVICE CENTER: MECKLENBURG COUNTY CODE ENFORCEMENT 2145 SUTTLE AVE, CHARLOTTE, NC 28208

CONTACT: AMY DIEKEVERS EMAIL: AMYD@PRECISIONPERMITS.COM P: 616-493-9334

---

SCALE: N.T.S.

STRUCTURAL FRAME (COLUMNS, ETC): BEARING WALLS (EXTERIOR): NON BEARING WALLS (EXTERIOR): NON BEARING (INTERIOR): FLOOR CONSTRUCTION ( INCL. SUPPORTS):

5. OCCUPANT GROUP: GROUP "M" (MERCANTILE)

7. OCCUPANT LOAD: (PER 2018 NC. BUILDING CODE: CHAPTER 10, TABLE 1004.2.1) FLOOR AREA: SALES: 1138 SQ FT / 60 = STOCK: 204 SQ FT / 300 = RESTROOM: 58 SQ FT/300 = NUMBER OF OCCUPANTS: TOTAL:

10. FIRE RATED ASSEMBLIES: A. EXISTING DEMISING PARTITIONS: • BACK WALL: 2-HR FIRE RATED 8" CMU PARTITION (UL-U905) INSULATED WITH 1 1/4" POLYISOCYANURATE FOAM SHEATHING (R 7.6) WITH 2 1/2" Z FURRING AT 24" O.C. AND (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD AT INTERIOR SIDE. FIRE-RATED ACOUSTICAL CAULKING TO SEAL ALL GAPS AT TOP AND BOTTOM OF PARTITION. G.C. TO PATCH AND RE-SEAL AS REQUIRED TO RESTORE THE DEMISING PARTITIONS TO THEIR ORIGINAL FIRE PROTECTION RATING. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. • SIDE WALLS: 1-HR FIRE-RATED PARTITION (UL-U465) WITH 5/8" TYPE "X" GYPSUM BOARD BOTH SIDES OF 6" METAL STUDS. FRAMING AND GYP. BD TO EXTEND TO BOTTOM OF METAL DECK ABOVE. FIRE-RATED ACOUSTICAL CAULKING TO SEAL ALL GAPS AT TOP AND BOTTOM OF PARTITION. G.C. TO PATCH AND RE-SEAL AS REQUIRED TO RESTORE THE DEMISING PARTITIONS TO THEIR ORIGINAL FIRE PROTECTION RATING. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. B. ALL PENETRATIONS (INCLUDING FOR PIPES AND CONDUITS) THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH UL LISTED THROUGH PENETRATION FIRESTOP SYSTEMS AND FIRE-RATED SEALANT WITH RATINGS EQUAL TO THAT OF THE RATED ASSEMBLIES THROUGH WHICH THEY PASS. C. COLUMNS, GIRDERS, BEAMS, JOISTS,AND SLABS ALL ARE PART OF LANDLORD ASSEMBLY AND HAVE EXISTING FIRE PROTECTION WHICH SHOULD REMAIN. EXISTING DECK IS 3 HOUR-RATED. WHERE SUCH FIRE PROTECTION IS DAMAGED, IT SHALL BE RESTORED TO ITS ORIGINAL CONDITIONS AND FIRE PROTECTION RATING. TENANT CEILING (NON-COMBUSTIBLE) DOES NOT FORM A PART OF THE LANDLORD RATED ROOF ASSEMBLY. D. ALL CEILING AND WALL MATERIALS MUST BE CLASS 'A'; INTERIOR FINISHES TO BE CLASS C OR GREATER. DOES NOT APPLY TO TRIM DEFINED AS BASEBOARDS AND MOLDINGS, OR TO MATERIALS LESS THAN 1/28 INCH IN THICKNESS APPLIED DIRECTLY TO SURFACE OF WALLS OR CEILINGS.

16. HANDICAP ACCESSIBILITY: A. AN ACCESSIBLE ROUTE IS EXISTING FROM THE EXTERIOR TO THIS TENANTS SPACE. SEE ORIGINAL LANDLORD SITE AND BUILDING PLANS ON FILE. B. THIS TENANT SPACE IS FULLY ACCESSIBLE TO ALL AREAS OCCUPIED BY THE PUBLIC, ACCESSIBLE EMPLOYEE WORK AREAS HAVE BEEN PROVIDED. C. WHERE INDICATED PROVIDE INDUSTRY STANDARD ADA APPROVED SIGNAGE, PROPOERLY ADDRESSING RAISED AND BRAILLE CHARACTERS, PICTOGRAMS, FINISH AND CONTRAST, CHARACTER PROPORTION AND HEIGHT, AND MOUNTING HEIGHT. 17. SANITARY FACILITIES: (PER 2018 N.C PLUMBING CODE TABLE 403.1) (1) EXISTING UNISEX RESTROOM, FULLY ACCESSIBLE TO CUSTOMERS AND EMPLOYEES TO BE PROVIDED BY LANDLORD 18. DRINKING FOUNTAIN: (PER 2018 N.C PLUMBING CODE TABLE 403.1) (1) WATER DISPENSER THAT COMPLIES WITH THE REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR & FOR STANDING PERSONS TO BE PROVIDED IN LIEU OF A DRINKING FOUNTAIN.

01 - GENERAL G-001 ACCESSIBILITY COMPLIANCE G-002 EGRESS & ACCESSIBILITY PLAN G-003 RESPONSIBILITY SCHEDULE G-004 APPENDIX B FORM

● ● ● ●

● ● ● ●

03 - ARCHITECTURAL A-100 CONSTRUCTION PLAN A-101 FIXTURE PLAN A-102 REFLECTED CEILING PLAN A-103 POWER & SIGNAL PLAN A-104 FLOOR & WALL FINISH PLAN A-300 BUILDING SECTIONS A-301 INTERIOR ELEVATIONS - CASUAL SHOP & TAILORED SHOP A-302 INTERIOR ELEVATIONS - CASUAL SHOP & TAILORED SHOP A-303 INTERIOR ELEVATIONS - LOUNGE & FITTING ROOMS A-304 INTERIOR ELEVATIONS - ADA FITTING ROOM/ VESTIBULE & RESTROOM A-305 INTERIOR ELEVATIONS - BOH DETAILS A-306 ENLARGED RESTROOM PLANS & ELEVATIONS A-400 FREE-STANDING FITTING ROOM DETAILS A-500 CONSTRUCTION & CEILING DETAILS A-501 CONSTRUCTION & CEILING DETAILS A-502 CONSTRUCTION DETAILS AT STOREFRONT A-600 PARTITION, TRIM, & THRESHOLD DETAILS A-601 DOOR & HARDWARE SCHEDULE & DETAILS A-602 STOREFRONT SIGNAGE DETAILS

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

04 - STRUCTURAL S-101 STRUCTURAL PLAN

05 - MECHANICAL M-100 MECHANICAL SPECIFICATIONS M-200 MECHANICAL PLAN

● ●

● ●

06 - PLUMBING P-100 PLUMBING SPECIFICATIONS P-200 PLUMBING PLAN

● ●

● ●

07 - ELECTRICAL E-100 ELECTRICAL TITLE SHEET E-200 ELECTRICAL SPECIFICATIONS (1 OF 2) E-201 ELECTRICAL SPECIFICATIONS (2 OF 2) E-300 ELECTRICAL POWER & LOW VOLTAGE PLAN E-400 ELECTRICAL LIGHTING PLAN E-500 POWER ONE-LINE DIAGRAM & PANEL SCHEDULES E-600 LIGHTING ENERGY COMPLIANCE E-601 LIGHTING ENERGY COMPLIANCE

● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ●

08 - FIRE PROTECTION FP-100 FIRE PROTECTION PLAN

CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550 STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

STAMP

19. SERVICE SINK: (PER 2018 N.C PLUMBING CODE TABLE 403.1) (1) SERVICE SINK TO BE PROVIDED

11. FIRE RESISTANCE RATING REQUIREMENT (PER 2018 NC. BUILDING CODE, TABLE 601) BUILDING ELEMENTS:

6. TENANT LEASE AREA: 1400 SQ.FT.

PRECISION PERMIT SERVICES 75 - 60TH SREET SW WYOMING, MI 49548

SITE PLAN

BUILDING CODE ANALYSIS & CODE NOTES

4. CONSTRUCTION TYPE: TYPE : IA FULLY SPRINKLERED NUMBER OF STORIES: 1 (TENANT WORK ON LEVEL ONE ONLY)

EXPEDITOR

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER

00 - COVER SHEET T-000 COVER SHEET

O

STRUCTURAL ENGINEER

OWNER'S REPRESENTATIVE

G-006 Unnamed

N

CONTACT: RANDY BUECHELE EMAIL: RBUECHELE@AEDIFICA.COM P: 636-649-1600 X224 F: 636-349-1730

2120 SOUTH BVLD, SUITE #2 CHARLOTTE, NC 28203

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

CONTACT: JIM SALOKA SENIOR CONSTRUCTION MANAGER EMAIL: JSALOKA@EDENS.COM P: 803-744-2475 M: 571-242-9998

RETAIL TENANT

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

RETAIL TENANT

EDENS 1221 MAIN STREET, SUITE 1000 COLUMBIA, SC 29201

ISSUE

ISSUE FOR CONSTRUCTION 03/04/2019

LANDLORD'S REPRESENTATIVE

ADJ. ADJACENT A.F.F ABOVE FINISHED FLOOR A.C.T. ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES BLK. BLOCKING CL CENTERLINE CLR. CLEAR CLG. CEILING CNTR. COUNTER CNT. CENTER CONC. CONCRETE COL COLUMN C.O.W CENTER OF WALL CPT. CARPET CONT. CONTINUOUS CONSTR. CONSTRUCTION C.G. CORNER GUARD CMU CONCRETE MASONRY UNIT DEMO DEMOLITION DWG. DRAWING DIA. DIAMETER DN. DOWN DR. DOOR ELEC. ELECTRICAL E.P. ELECTRICAL PANEL EMER. EMERGENCY EQ. EQUAL (E) EXISTING EA. EACH EXT. EXTERIOR FBO. FURNISHED BY OWNER F.C. FIXTURE CONTRACTOR F.F. FINISH FLOOR F.D. FLOOR DRAIN FR FRAME F.R.T FIRE RETARDANT TREATED F.S. FIRE EXTINGUISHER FURN. FURNISH F.O.W. FACE OF WALL GA. GAUGE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GWB. GYPSUM WALL BOARD HC HOLLOW CORE H.M. HOLLOW METAL HGT. HEIGHT HORIZ. HORIZONTAL IN INCH INST. INSTALL INSUL INSULATION KE KITCHEN EQUIPMENT L.O.D. LEASE OUTLINE DRAWING L.N. LANDLORD MAX MAXIMUM MAT'L. MATERIAL M.D.F. MAIN DISTRIBUTION FACILITY MECH. MECHANICAL MFR. MANUFACTURER MIR. MIRROR MIN. MINIMUM M.R. MOISTURE RESISTANT M.O. MASONRY OPENING N/A NOT APPLICABLE (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPG. OPENING OPP. OPPOSITE PT. PAINT PLWD. PLYWOOD P-LAM. PLASTIC LAMINATE PNL. PANEL QTY. QUANTITY RCP REFLECTED CEILING PLAN RB. RUBBER BASE REINF. REINFORCING REQ'D. REQUIRED REV. REVISED/REVISION R.R. RESTROOM SC SOLID CORE SCHED. SCHEDULE SF. SQUARE FOOT SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE SUSP. SUSPENDED TEMP. TEMPERED TBD TO BE DETERMINED TBV TO BE VERIFIED TYP. TYPICAL UON UNLESS OTHERWISE NOTED V.C.T. VINYL COMPOSITE TILE V.I.F VERIFIED IN FIELD VERT. VERTICAL WD WOOD

ARCHITECT

DRAWING LIST

ABBREVIATIONS

ISSUE FOR LANDLORD APPROVAL/BID 02/27/2019

TENANT

19 OCCUPANTS 1 OCCUPANT 1 OCCUPANT 21 OCCUPANTS

8. EXITS REQUIRED: OCCUPANT LOAD < 50 REQUIRES MINIMUM OF 1 EXIT (PER 2018 NC. BUILDING CODE: SECTION 1006.2.1) NUMBER OF EXITS REQUIRED BY OCCUPANT LOAD: 1 NUMBER OF EXITS PROVIDED: 2 MAXIMUM TRAVEL DISTANCE TO MALL: 75 FT (PER 2018 NC. BUILDING CODE: SECTION 1006.2) MAXIMUM TRAVEL DISTANCE TO MALL EXIT: 250 FT (PER 2018 NC. BUILDING CODE: SECTION 1017.2 ) ACTUAL TRAVEL DISTANCES (REF. G-003 EGRESS PLAN): ROUTE 1: 55'-3" ROUTE 2: 49'-10" ROUTE 3: 17'-9" EGRESS WIDTH PER OCCUPANT SERVED: (0.15) x 21 PERSONS = 3.15 IN 9. EXITS PROVIDED AND DATA: ONE (1) EXISTING EXIT TO MALL AT STOREFRONT @ 5'-4 1/2" (2 LEAVES X 2'-8 1/4") CLEAR WIDTH ONE (1) EXISTING EXIT AT BOH @ 2'-10 1/4" CLEAR WIDTH A. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. B. A CLEAR AISLE BETWEEN EXITS OF 36" SHALL BE MAINTAINED FREE OF FIXTURES, MERCHANDISE AND OTHER OBSTRUCTIONS. C. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED AND SHALL CONFORM TO 2018 NC. BUILDING CODE.

3 HR 3 HR 0 HR 0 HR 2 HR

BASED ON FIRE SEPARATION DISTANCE (PER 2018 NC. BUILDING CODE, TABLE 602) EXTERIOR WALLS: 10≤X< 30: 1 HR 12. LIFE SAFETY SYSTEMS: A. FIRE SPRINKLER SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. SPRINKLER CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ONSITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. B. FIRE ALARM SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. FIRE ALARM CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ON-SITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. C. EMERGENCY LIGHTING - NEW, PROVIDED BY TENANT

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

13. FLAME SPREAD RATINGS FOR INTERIOR FINISHES: FLAME SPREAD RATINGS FOR INTERIOR FINISHES SHALL COMPLY WITH 2015 IFC, TABLE 803.3 BUT IN NO CASE SHALL EXCEED CLASS C, MAX FLAME SPREAD INDEX OF 75; MAX SMOKE-DEVELOPED INDEX OF 450 14. FIRE EXTINGUISHERS: (PER 2015 IFC, TABLE 906.1, TABLE 906.3(1)) A. ONE FIRE EXTINGUISHER SHALL BE PROVIDED AT ONE PER 3,000 SF; COVERAGE NOT TO EXCEED 75 FEET IN ANY DIRECTION. TENANT SHALL HAVE AT LEAST ONE IN THE STOCK ROOM AREA. B. PROVISIONS AND INSTALLATION IN THE QUANTITY, TYPE AND LOCATIONS REQUIRED BY THE FIRE MARSHALL SHALL PREVAIL.

COVER SHEET

15. HAZARDOUS MATERIALS: TESTING, REMOVAL, AND/OR ENCAPSULATION ARE NOT PART OF THIS CONTRACT. IT IS NOT SUSPECTED ANY HAZARDOUS MATERIALS WILL BE FOUND. IF THE PRESENCE OF HAZARDOUS MATERIAL IS SUSPECTED OR DISCOVERED, NOTIFY THE BUILDING OWNER AND CLIENT IMMEDIATELY.

T-000

DATE 02/27/2019 03/04/2019


ARCHITECT

C

B

A

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

OWNER'S REPRESENTATIVE

FE

TRAVEL DISTANCE FROM POINT A TO EXIT 1: 55'-9"

MEP ENGINEER

TRAVEL DISTANCE FROM POINT B TO EXIT 1: 55'-3"

CASE ENGINEERING, INC.

TRAVEL DISTANCE FROM POINT C TO EXIT 2: 17'-9"

cCLEAR

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550

20' - 10"

3' 0" CL EA R

3' - 0"

LEASE LINE TO LEASE LINE

CLEAR CLEAR

5' - 4 1/2"

2' - 8 1/4" EXIT 1

2' - 8 1/4"

CLEAR

3' - 0"

EXIT 2

CLEAR

CLEAR

3' - 0"

CLEAR

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

3' - 0"

CLEAR

2' - 10 1/4"

3' - 0"

POINT B

STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

NORTH

EGRESS PLAN SCALE: 1/4" = 1'-0"

EGRESS PLAN SYMBOL / HATCH LEGEND SYMBOL / HATCH

DESCRIPTION

EXISTING PARTITION TO REMAIN

36" CLEAR

NEW PARTITION

4"

EGRESS PLAN GENERAL NOTES:

EGRESS PATH

OCCUPANT GROUP

1. IT IS THE RESPONSIBILITY OF THE G.C. TO FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS.

GROUP 'M' MECHANTILE

2. NOTHING SHALL BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THROUGH THE FLOOR OR ROOF DECK ABOVE.

AREA & EGRESS CALCULATIONS

3. IT IS THE RESPONSIBILITY OF THE G.C. TO FIELD VERIFY EXISTING ELECTRICAL SERVICE AND TO MAKE ANY AND ALL MODIFICATIONS REQUIRED TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED ELECTRICAL SERVICE. 4. ENSURE THAT LAYOUT AND ALL FIXTURES COMPLY WITH LATEST CODE AND ADA REQUIREMENTS.

2" MIN

5. FIRE EXTINGUISHER SHALL BE PLACED NO LESS THAN 18 INCHES ADJACENT TO THE DOOR FROM THE FORWARD APPROACH ON THE PULL SIDE AND NO LESS THAN 12 INCHES ADJACENT TO THE DOOR FROM THE PUSH SIDE.

SPACE TYPE/ NAME SALES AREA STOCK ROOM RESTROOM TOTAL

SF AREA 1138 SF (GROSS) 204 SF (GROSS) 58 SF (GROSS) 1400 SF (GROSS)

OCCUPANCY LOAD SF / 60 = 19 OCCUPANTS SF / 300 = 1 OCCUPANTS SF / 300 = 1 OCCUPANTS 21 OCCUPANTS

TOTAL % 81% 15% 4% 100 %

EXITS PROVIDED EXIT EXIT 1- STOREFRONT ENTRY EXIT 2- BACK OF HOUSE EXIT

WIDTH 2 LEAVES X (2'-8 1/4") CLEAR EACH 2'- 10 1/4" CLEAR (32" MIN. CLEAR)

STAMP

EXIT SIGN; REF. RCP FOR FULL SPEC AND LOCATION

FIRE EXTINGUISHER

MOUNTING BRACKET AS REQUIRED

WALL MOUNTED FIRE EXTINGUISHER FE

OCCUPANTS

X INCHES/ OCCUPANT .15 (INCHES PER OCCUPANT)

21

3.15"

NOTE: TOTAL WIDTH REQUIRED LESS THAN MINIMUM REQUIRED EXIT WIDTH OF 36" CLEAR

EGRESS TRAVEL DISTANCE

(48" MAX.)

1' - 0"

EXIT CAPACITY REQUIRED

3' - 4"

1

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

10

FE

POINT A

RETAIL TENANT

POINT C

CLEAR

3' - 0"

CLEAR

ROUTE DISTANCE POINT A TO EXIT 1 55'- 3" (<75 MAX DISTANCE TO EXIT) POINT B TO EXIT 1 49'- 10" (<75' MAX DISTANCE TO EXIT) POINT C TO EXIT2 17'- 9" (<75' MAX DISTANCE TO EXIT) MAX COMMON PATH OF TRAVEL PROVIDED = 60'-11" (MAX ALLOW 75') WALL BASE AS SCHEUDLED FINISHED FLOOR AS SCHEUDLED

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

FIRE EXTINGUISHER NOTE:

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

ADA COMPLIANT TYPE "ABC" ALL PURPOSE CHEMICAL FIRE EXTINGUISHER & MOUNTING BRACKET TO BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR AT A HEIGHT OF 4'-0" MAX. SPECIFICATIONS: FIRE EXTINGUISHER: MODEL NO: PART NO: AGENT CAPACITY: U.L. RATING: HEIGHT: BRACKET:

4

BY ANSUL NAMED "SENTRY 10" AA10S 436500 10 LBS. FORAY 4A:80B:C 20.5 IN 435793

FIRE EXTINGUISHER DETAIL SCALE: 1 1/2" = 1'-0"

EGRESS & ACCESSIBILITY PLAN

G-002


RESPONSIBILITY SCHEDULE

SECURITY

TBD

ADT BUSINESS TEX CROMWELL 744 MELROSE AVE NASHVILLE,TN 37211 PH: 615.743.0102 C: 615.779.9872 TEXCROMWELL@ADT.COM

LIGHTING

CAPITAL LIGHT ANGELA McCOY 270 LOCUST STREET HARTFORD, CT 06141 PH: 860-520-2387 C: 860-729-2717 ANGELA.MCCOY@CAPITALLIGHT.COM FIXTURE CONTRACTOR

ICON DESIGN WALTER WROUGHTON 230 SOUTH BEMISTON ST LOUIS, MO 63105 P: 314-725-5721 Ext 102 C: 314-210-3985 WALTERW@ICONFIXTURES.COM DRAPERY FABRIC

BRAD JOBE BESPOKE FURNITURE BRAD JOBE 231 W 29TH ST SUITE 300 NEW YORK, NY 10001 PH: 212-216-9259 BRAD@BRADJOBE.COM CONCRETE FLOORING

UNCONVENTIONAL FLOORING JASON VALENTA PH: 317-281-8223 VALENTAJASON@HOTMAIL.COM

01.

N/A

EX'G

PROVIDE

FURNISH

INSTALL

COMMENTS

10.

GENERAL REQUIREMENTS 1. PERMITS AND FEES

G.C.

G.C.

2. INSPECTION / COORDINATION

G.C.

G.C.

3. SPECIAL INSPECTIONS

DESCRIPTION

X

OWN

OWN

BUILDING PERMIT FEE BY OWNER; CONTRACTOR SPECIFIC PERMITS INCLUDING, FIRE ALARMS, SPRINKLER, PLUMBING & ELECTRICAL BY G.C. ( IF APPLICABLE)

N/A

PROVIDE

FURNISH

INSTALL

LL

LL

LL

G.C. TO ENSURE MOUNTING HEIGHTS AND LOCATIONS ARE CODE COMPLIANT; RELOCATE AS REQ'D

2. STOREFRONT SIGNAGE

OWN

OWN

OWN/VEN

FURNISHED AND INSTALLED BY SIGNAGE VENDOR; G.C. TO SUPERVISE AND COORD. INSTALL

3. DRAPERY

OWN

VEN

G.C.

FURNISHED BY OWN. VENDOR; DELIVERED TO G.C. FOR INSTALLATION

4. LOCKERS

G.C.

G.C.

G.C.

5. SHELVING @ BACK OF HOUSE

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL FROM THE CONTAINER STORE; G.C. TO PROVIDE LAYOUT FROM CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE.

6. ADA TACTILE SIGNAGE

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL PER LOCAL CODE

7. FIRE EXTINGUISHER

G.C.

G.C.

G.C.

AS PER LOCAL CODE AND FIRE DEPARTMENT

X

AUDIO SYSTEM

4. TEMPORARY HEAT

G.C.

G.C.

PLAY NETWORK AUDIO JEFF ROMAN C: 425-629-2760 JROMAN@PLAYNETWORK.COM

5. TEMPORARY ELECTRICAL

G.C.

G.C.

6. WINDOW GRAPHICS

G.C.

G.C.

7. CLEAN UP

G.C.

G.C.

8. INSURANCE

G.C.

G.C.

SHOPPER TRAK

9. JOB PHONE

G.C.

G.C.

1. SALES REFRIGERATOR (REF-1)

OWN

OWN/F.C.

G.C.

OWNER TO PROVIDE REF-1 / F.C. TO STORE AND DELIVER WITH FIXTURE PACKAGE / G.C. TO COORD. INSTALL WITH BAR FIXTURE (F.16)

RETAIL NEXT EDWARD SCHLODDER OFFICE ON THE BEACH 3 LAGOON BEACH DRIVE MILNERTON, SOUTH AFRICA 7441 P: (408) 740-5340 Ext 1035 EDWARD.SCHLODDER@RETAILNEXT.NET

10. FINAL CLEANING

G.C.

G.C.

2. BOH REFRIGERATOR (REF-2)

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL; COORD. W/ MEP'S; COORD. INSTALL WITH BOH SHELVING

02.

G.C.

2. SAW CUT/ DRILL SLAB 3. SIDE WALK PAVERS

BANDWAVE SYSTEMS, LLC ADIL ZAIDI 438 HIGH ST BURLINGTON, NJ 08016 P: 888-396-7182 M: 609-699-4265 AZAIDI@BANDWAVESYSTEMS.COM

4. MALL FLOORING 03.

X X

11.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

FURNISHINGS 1. MILLWORK/FIXTURES & FURNITURE

F.C.

F.C.

G.C.

FLOOR, WALL, & FITTING ROOM FIXTURES FURNISHED BY F.C. / INSTALLED BY G.C.

2. MANAGER'S DESK

G.C.

G.C.

G.C.

G.C. TO FURNISH FROM IKEA AND INSTALL ON TELE/DATA BOARD

AS REQUIRED FOR ELECTRICAL, PLUMBING, & FLOORING

3. MANAGER'S CHAIR

OWN

OWN

OWN/ G.C.

G.C. TO SCHEDULE AND COORD. DELIVERY

4. WALK OFF MATT- ENTRY (REMOVABLE)

G.C.

G.C.

G.C.

NEW REMOVABLE WALK-OFF MAT AT ENTRY

5. AREA RUG (REMOVABLE)

OWN

OWN

OWN

NEW AREA RUG BY OWNER (RETAIL TENANT) AT LOUNGE

G.C. TO CONFIRM SLAB CONDITIONS

2. VAPOR BARRIER

X

G.C.

G.C.

G.C.

3. CONCRETE SLAB

X

G.C.

G.C.

G.C.

G.C. PATCH AND REPAIR FLOOR AS REQUIRED, AND PREPARE FOR NEW FLOOR FINISH

X

G.C.

G.C.

G.C.

ADD ALT: IF LANDLORD DOES NOT PROVIDE SLAB IN-FILL AT LEAVE OUT, G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT; REF. LANDLORD DWGS. FOR REQUIRED SLAB IN-FILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS

G.C.

G.C.

G.C.

5. EXPANSION JOINT MATERIAL

EQUIPMENT

G.C. TO DEMOLISH EXISTING BACK DOOR AND DOOR FRAME, REF PLAN; G.C TO PROVIDE NEW 2-HR RATED CMU PARTITION (UL-U905) W/ RIGID INSULATION, METAL Z-FURRING AND 5/8"THK GYP BOARD AT INTERIOR; REF. PARTITION SCHEDULE FOR DETAILS

CONCRETE SLAB 1. LEVELING OF CONCRETE FLOOR

04.

G.C. TO COORDINATE INSTALL OF WINDOW GRAPHICS WITH OWNER'S VENDOR

12.

1. DEMOLITION

DATA

OWN'S VEN

EXISTING CONDITIONS / SITE WORK

4. CONCRETE SLAB IN-FILL

13.

SPECIAL CONSTRUCTION - N/A

14.

CONVEYING EQUIPMENT - N/A

21.

FIRE SUPPRESSION

22.

LL

LL

LL

PROVIDE

05.

1. STRUCTURAL STEEL

X

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED

B. INTERIOR PARTITIONS

G.C.

G.C.

G.C.

G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS

C. FURRING

G.C.

G.C.

G.C.

G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

2. FIRE ALARM SHOP DRAWINGS AND DEVICES

OLA / MEP ENG

3. MECHANICAL SHOP DRAWINGS AND EQUIPMENT

OLA / MEP ENG

A. TENANT DEMISING WALLS

4. ELECTRICAL EQUIPMENT AND DEVICES

OLA / MEP ENG

5. PLUMBING FIXTURES

OLA / MEP ENG

2. METAL STUDS X

G.C.

A. WATER

G.C.

G.C.

G.C.

NEW WATER PIPES FOR MOP SINK AND WATER COOLER TO TIE-IN TO EXISTING COLD WATER AT BOH; COORD. W/ PLUMBING DWGS

B. WASTE

G.C.

G.C.

G.C.

NEW SANITARY PIPES FOR MOP SINK TO TIE-IN TO EXISTING, COORD. W/ PLUMBING DWGS

C. VENT

G.C.

G.C.

G.C.

2. PLUMBING FIXTURES

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW PLUMBING FIXTURES AT B.O.H.; EXISTING RESTROOM FIXTURES TO REMAIN; COORD. W/ PLUMBING DWGS

3. WATER HEATER

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW WATER HEATER ON SHELF ABOVE MOP SINK; COORD. W. PLUMBING DWGS

G.C.

G.C.

G.C.

EXISTING WATER METER TO REMAIN

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW WATER COOLER; COORD. W/ PLUMBING DWGS

G.C.

G.C.

G.C.

EXISTING ROOFTOP CONDENSER AND AHU TO REMAIN; G.C. TO SERVICE AND CONFIRM FUNCTIONING COORD.. W/ MECHANICAL DWGS.

G.C.

G.C.

G.C.

COORD. W/ MECHANICAL DWGS.

G.C.

G.C.

G.C.

COORD. W/ MECHANICAL DWGS.

LL

LL

G.C.

EXISTING EXHAUST FAN TO REMAIN; G.C. TO RELOCATE AS REQUIRED FOR NEW CEILING LAYOUT; COORD. W/ MECHANICAL DWGS.

X

5. WATER COOLER

23.

A. UNIT

X

OLA / ENG.

3. FRAMING FOR HVAC

7. STOREFRONT SHOP DRAWINGS AND SAMPLES

X

OLA

4. STOREFRONT SYSTEM

8. DOORS AND HARDWARE

OLA

5. METAL DECKING

9. FLOOR FINISH SAMPLES

OLA /RETAIL TENANT

10. PAINT DRAW DOWNS

OLA

1. BLOCKING

G.C.

G.C.

G.C.

G.C. TO COORD. W/ FIXTURE CONTRACTOR

4. FIRE/SMOKE DAMPER

G.C.

G.C.

G.C.

COORD. W/ MECHANICAL DWGS. & LOCAL CODE REQUIREMENTS

11. BOH SHELVING LAYOUT

OLA /RETAIL TENANT

2. SHELVES

G.C.

G.C.

G.C.

G.C TO COORD. ALL MILLWORK REQUIREMENTS W/ FIXTURE CONTRACTOR

5. FIRE STOP / SMOKE BARRIER

G.C.

G.C.

G.C.

COORD. W/ MECHANICAL DWGS. & LOCAL CODE REQUIREMENTS

12. WOOD JOINERY AND MILLWORK

OLA /RETAIL TENANT

4. PLYWOOD

G.C.

G.C.

G.C.

FOR IN-WALL BLOCKING, TELE/DATA BOARD AT BOH

25.

INTEGRATED AUTOMATION - N/A

5. FURRING

G.C.

G.C.

G.C.

G.C TO COORD. ALL MILLWORK BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR

26.

ELECTRICAL G.C.

G.C.

G.C.

COORD. W/ ELECTRICAL DWGS.

06.

G.C. TO PROVIDE A SUBMITTALS SCHEDULE AT CONSTRUCTION KICK-OFF FOR ARCHITECT'S REVIEW

GENERAL NOTES

07.

B. DUCTWORK / DIFFUSERS 2. TEMPERATURE CONTROLS 3. EXHAUST FANS AND GRILLES

CARPENTRY

THERMAL / MOISTURE CONTROL 1. CAULKING

G.C.

G.C.

G.C.

2. SEALANT

G.C.

G.C.

G.C.

3. WATERPROOFING

G.C.

G.C.

G.C.

PROVIDE WATERPROOFING AT ALL WET AREAS

2. G.C. SHALL FILE ANY NECESSARY CERTIFICATES OF INSURANCE WITH THE LOCAL DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED.

4. INSULATION

G.C.

G.C.

G.C.

G.C. TO DEMOLISH EXISTING BACK DOOR AND DOOR FRAME, REF PLAN; G.C TO PROVIDE NEW 2-HR RATED CMU PARTITION (UL-U905) W/ RIGID INSULATION, METAL Z-FURRING AND 5/8"THK GYP BOARD AT INTERIOR; REF. PARTITION SCHEDULE FOR DETAILS

4. G.C. SHALL THOROUGHLY REVIEW ALL EXISTING CONDITIONS PRIOR TO BIDDING. ANY DISCREPANCIES BETWEEN THE BID DOCUMENTS AND EXISTING CONDITIONS SHALL BE BROUGHT THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO BIDDING.

08.

5. G.C. IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.

7. G.C. SHALL INSTALL ALL NECESSARY MEANS TO PROTECT THE PUBLIC , THE BUILDING, AND NEW WORK FROM DAMAGE DURING THE DURATION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO FLOOR PROTECTION, TEMPORARY DUST PARTITIONS AND BARRICADES. 8. G.C. SHALL CONDUCT WORK IN A SAFE AND TIMELY MANNER. PROVIDE AND MAINTAIN ALL NECESSARY GUARDS FOR PREVENTION OF ACCIDENTS. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION, SAFETY ISSUES, CONTROL OR SUPERVISION OF THE WORK, NOR ITEMS RELATED TO STOPPAGE OF WORK. THE AUTHORITY TO STOP WORK REMAINS SOLELY WITH RETAIL TENANT (OWNER) AND G.C.. 9. G.C. SHALL COMPLETE ALL WORK WITHOUT DISRUPTION TO ADJACENT BUILDING TENANTS. 10. G.C. SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. G.C. SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. 11. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING - CREATED OR EXPOSED DURING CONSTRUCTION, PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 12. PRIOR TO PROJECT CLOSEOUT, G.C. SHALL COORDINATE WITH THE BUILDING OWNER: ANY TESTS, SUBMITTAL OF AS-BUILT DOCUMENTATION AS REQ'D, AND ALL REQUIREMENTS FOR PROJECT ACCEPTANCE. 13. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.

X

G.C.

G.C.

G.C.

6. FLASHING

X

G.C.

G.C.

G.C.

G.C. TO INSTALL FLASHING AT CMU WALL INFILL

1. ENTRY DOOR

X

LL

LL

G.C.

SUPPLY NEW 'BEST' 7-PIN SFIC LOCK WITH INTERCHANGEABLE CYLINDER AND 6 SETS OF KEYS

2. RESTROOM DOOR

X

LL

LL

LL/G.C.

G.C. TO REPLACE EXISTING HARDWARE WITH COMPATIBLE BLACK HARDWARE; REF. HARDWARE SCHEDULE

F.C.

F.C.

G.C.

DOOR, FRAME, AND HARDWARE FURNISHED BY F.C. U.N.O. AND INSTALLED BY G.C. SILENCERS AND MIRROR BY G.C. REF. HARDWARE SCHEDULE; G.C. TO COORD. ROUGH OPENING W/ APPROVED SHOP DWGS

LL

LL

G.C.

SUPPLY NEW 'BEST' 7-PIN SFIC LOCK WITH INTERCHANGEABLE CYLINDER AND 6 SETS OF KEYS

G.C.

G.C.

G.C.

DOOR HARDWARE PROVIDED BY G.C., EXCEPT OWNER TO PROVIDE BOH DOOR DEADLOCK & 6 SETS OF KEYS / F.C. TO STORE AND DELIVER WITH FIXTURE PACKAGE / G.C. TO INSTALL LOCK AT BOH DOOR

LL

LL

LL

G.C.

G.C.

X

5. DOOR HARDWARE

6. STOREFRONT SYSTEM 09.

X

G.C.

27.

B. RESTROOM

C. BACK OF HOUSE

G.C.

G.C.

G.C. TO RE-CIRCUIT EXISTING ELECTRICAL PANEL AS REQUIRED; COORD. W/ ELECTRICAL DWGS.

3. TRANSFORMER

X

LL

LL

G.C.

G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; COORD. W/ ELECTRICAL AND STRUCT DWGS.

4. LIGHT SWITCHES

OWN

OWN/VEN

G.C.

SWITCHES PROVIDED BY OWNERS VENDOR; G.C. TO PROVIDE MASTER OVERRIDE SWITCH

5. LIGHT FIXTURES IN CEILING

OWN

OWN/VEN

G.C.

G.C. TO COORD. DELIVERY & INSTALL; COORD. W/ ELECTRICAL DWGS.

X

X X

G.C.

G.C. G.C.

G.C.

G.C. G.C.

G.C.

G.C. G.C.

OWN

OWN/VEN

G.C.

COORD. W/ ELECTRICAL DWGS.

LL

LL

G.C.

EXISTING EXHAUST FAN TO REMAIN; G.C. TO RELOCATE AS REQUIRED FOR NEW CEILING LAYOUT; COORD. W/ MECHANICAL DWGS.

9. EMERGENCY LIGHTING

OWN

OWN/VEN

G.C.

COORD. W/ ELECTRICAL DWGS.

11. DISCONNECT SWITCH

G.C.

G.C.

G.C.

COORD. W/ ELECTRICAL DWGS.

12. TIME CLOCK

G.C.

G.C.

G.C.

MULTI-CHANNEL, 24/7 PROGRAMMABLE TIME CLOCK; COORD. W/ ELECTRICAL DWGS.

13. FLOOR OUTLETS

G.C.

G.C.

G.C.

G.C. TO PROVIDE DEDICATED FLOOR BOX; G.C. IS RESPONSIBLE FOR ANY TRENCHING OR CORING, PATCHING AND REPAIRING OF THE FLOORING REQUIRED FOR INSTALLATION OF THE FLOOR BOX.

1. CONDUIT FOR COMPUTER SYSTEM

G.C.

G.C.

G.C.

COORD. W/ BRAND WAVE

2. TELEPHONE CONDUIT

G.C.

G.C.

G.C.

3. TELEPHONE JACKS/SETS/WIRES

G.C.

G.C.

G.C.

4. AUDIO SYSTEM - SPEAKERS AND CONTROLS

G.C.

G.C.

G.C./ OWN

CONDUIT & PULL STRINGS BY G.C. AS REQ'D; G.C. TO SCHEDULE & COORD. INSTALL W/ VEND

OWN

OWN

G.C.

THERE ARE NO POINT-OF SALES OR SERVICE COUNTERS IN THIS STORE. RETAIL TENANT STORES ARE DESIGNED AND OPERATE AS SHOWROOMS. MO MERCHANDISE IS SOLD ON LOCATION.

OWN

OWN

G.C.

G.C. TO PROVIDE PULL STRING AS REQ'D; COORD. W/ VENDOR

1. CAMERA SECURITY SYSTEM

OWN

OWN

G.C.

RETAIL TENANT VENDOR FURNISHES & INSTALLS CAMERA WIRING, CAMERA, & CPU; G.C. TO PROVIDE CONDUIT & PULL, SCHEDULE AND COORD. W/ VENDOR

2. LIFE SAFETY

G.C.

G.C.

G.C.

A. FIRE ALARM

G.C.

G.C.

G.C.

MODIFICATION TO EXISTING SYSTEM TO TIE-IN TO EXISTING LANDLORD FIRE ALARM CONTROL PANEL AT ELECTRICAL ROOM BEHIND TENANT SPACE; COORD. W/ APPROVED FIRE ALARM DWGS.

B. SMOKE DETECTORS

G.C.

G.C.

G.C.

SEE ELECTRICAL AND MECHANICAL DWGS.

EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO GRIND, STAIN, POLISH AND SEAL; ADD ALT: PROVIDE NEW VAPOR BARRIER UNDER SLAB INFILL IF SLAB INFILL NOT PROVIDED BY LANDLORD

28.

ELECTRONIC SAFETY AND SECURITY

EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO GRIND AND SEAL

G.C.

G.C.

G.C. TO COORD. IN-WALL BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR

G.C.

G.C.

G.C.

G.C. TO PATCH W/ MOISTURE RESISTANT GYP. BOARD AS REQ'D; COORD. W/ MEP

C. BACK OF HOUSE

G.C.

G.C.

G.C.

D. MOP SINK

G.C.

G.C.

G.C.

X

X

6. SHOPPER TRACK SYSTEM

EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO GRIND, STAIN, POLISH AND SEAL; ADD ALT: PROVIDE NEW VAPOR BARRIER UNDER SLAB INFILL IF SLAB INFILL NOT PROVIDED BY LANDLORD

G.C.

B. RESTROOM

X

INSTALL WATERPROOF PLASTEX POLYWALL UP TO 48" AFF MIN.,; ENSURE MOISTURE RESIST. GWB IS INSTALLED IN AND AROUND WET AREAS

4. BASE

KEY

DESCRIPTION

G.C. (OR) GC

GENERAL CONTRACTOR

OWN. (OR) OWN

OWNER / RETAIL TENANT

LL

LANDLORD

F.C. (OR) FC

FIXTURE CONTRACTOR

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW PAINTED WOOD BASE

B. RESTROOM

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW PAINTED WOOD BASE

AV

AUDIO/VISUAL CONSULTANT

C. BACK OF HOUSE

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW RUBBER WALL BASE

X

N/A OR EXISTING

N/A

NOT APPLICABLE-DOES NOT APPLY TO PROJECT

A. STOREFRONT DISPLAY WINDOW

G.C.

G.C.

G.C.

NEW GYP. BOARD CEILING

EX'G

EXISTING - ALREADY LOCATED ON SITE

B. CASUAL/TAILORED SHOP

G.C.

G.C.

G.C.

OPEN TO EXISTING DECK ABOVE; G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED

PROVIDE

TO FURNISH & INSTALL ( WHEN TENANT RESPONSIBILITY, TENANTS SUPPLIERS TO FURNISH & INSTALL)

C. LOUNGE/ VEST/ FITTING ROOMS / TRANSITIONS/ RESTROOM

G.C.

G.C.

G.C.

FURNISH

TO SUPPLY AND DELIVER

INSTALL

TO INSTALL

D. BACK OF HOUSE

G.C.

NEW GYP. BOARD CEILING; AT RESTROOM ONLY DEMOLISH EXISTING ACT CEILING AND 2x4 LIGHT; PRIOR TO INSTALL OF NEW GYP. BOARD CEILING; (DEDUCT ALT: EXISTING ACT CEILING AND LIGHT TO REMAIN; CONFIRM WITH TENANT PRIOR TO DEMO ) OPEN TO EXISTING DECK ABOVE; G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED

OWN/VEN

OWNER'S VENDOR

G.C.

G.C.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

RESPONSIBILITY SCHEDULE LEGEND

A. SALES AREA / VESTIBULE/ FITTING ROOMS

5. CEILING

STAMP

COMMUNICATIONS

3. WALLS

A. SALES AREA / VESTIBULE / FITTING ROOMS/

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

X

5. POS SYSTEM

2. FINISH FLOORING A. SALES AREA / VESTIBULE / FITTING ROOMS

G.C.

8. EXHAUST FAN

FINISHES 1. GYPSUM FOR PARTITIONS

X

6. LIGHT FIXTURES IN MILLWORK

DOORS / OPENINGS

4. BACK EXIT DOOR

2. PANELS

7. EXIT SIGNAGE

5. METAL CLADDING

3. BACK OF HOUSE DOOR

6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE HIGHEST QUALITY INDUSTRY STANDARDS FOR MATERIAL AND INSTALLATION. ALL WORK WILL BE WARRANTIED FOR ONE YEAR MIN. BY THE G.C. UNLESS STATED OTHERWISE. REPAIR OR REPLACEMENT OF WARRANTIED WORK AND ANY AREA AFFECTED BY FAILURE OF WARRANTIED ITEM SHALL BE THE G.C.'S RESPONSIBILITY.

X

1. DISTRIBUTION

1. G.C. SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS, FEES, APPROVALS, AND TEST FOR THE WORK. ALL CONSTRUCTION AND MATERIALS SHOULD COMPLY WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS / LAWS / CODES.

3. ALL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP.

STRUCTURAL ENGINEER

1. HVAC

X

X

LICENSE # C-4550

HEATING, VENTILATING, AND AIR-CONDITIONING

6. STRUCTURAL SHOP DRAWINGS

X

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

MODIFICATION OF EXISTING SYSTEM FOR NEW TENANT LAYOUT; COORD. W/ APPROVED SPRINKLER DWGS.

G.C.

4. WATER METER

REF. STRUCTURAL DWGS; G.C. TO ENSURE FIRE-PROOFING RATING FOR EXISTING STRUCTURE IS MAINTAINED/REPLACED

G.C.

CASE ENGINEERING, INC.

1. PIPING

INFILL AT BACK WALL TO BE EXISTING BY LANDLORD

G.C.

OLA / MEP ENG.

MEP ENGINEER

PLUMBING

METALS

1. SPRINKLER SHOP DRAWINGS AND DEVICES

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

ENGINEERING

G.C. REQUIRED SHOP DRAWINGS N/A

OWNER'S REPRESENTATIVE

OSBORN G.C.

X

2. CONCRETE MASONRY BLOCK

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

TM

1. SPRINKLER SYSTEM

MASONRY 1. BRICK

DESCRIPTION

COMMENTS

SPECIALTIES 1. TOILET ROOM ACCESSORIES

SPECIAL INSPECTOR CONTRACTED BY OWNER; G.C. TO COORD. SCHEDULE AND ACCESS TO SITE FOR INSPECTIONS

EX'G

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

DESCRIPTION

SIGNAGE

ARCHITECT

RESPONSIBILITY SCHEDULE

RETAIL TENANT

REQUIRED VENDORS CONTACT INFO

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

RESPONSIBILITY SCHEDULE

G-003


ARCHITECT

61' - 10"

3' - 9 3/4"

1' - 10"

LEASE LINE TO LEASE LINE

VESTIBULE 06

7' - 11 3/8"

7' - 3 3/4"

B

2' - 1 7/8"

A 11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

16 13

15

TYP. 6

5' - 8 3/4"

5' - 6"

29' - 3"

VIF

2 1/2"

1 2

1 3

2' - 5"

3 5/8"

1

D

8

TYP.

TYP.

14 TYP.

12 A-501

D

3' - 9"

8

D

ADA FITTING ROOM 05

6' - 11 3/8"

HOLD

14

14

18

2' - 5"

5

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

DISPLAY WINDOW 02

10

8

1

24' - 10"

2 A-300

TM

ALIGN

D

18

TYP.

12' - 9 5/8"

STRUCTURAL ENGINEER

A-300

1

D

1' - 1"

14

A

BOH 08

7 C

3

ALIGN

4' - 10"

A-304

HOLD

1

8

14

1

4

2' - 6"

9

4' - 10"

TYP.

6' - 11"

9

3' - 2"

HOLD

6' - 6 1/8"

3

4' - 5" HOLD

D

HOLD

5

14

2

HOLD

3' - 0"

10

1

24' - 10"

9"

HOLD

A-302

1' - 10 1/2"

13' - 10 3/4"

12' - 4 3/4"

C

2

LICENSE # C-4550

1' - 4 5/8"

6' - 9"

A-301

9' - 5 7/8"

8

V.I.F.

9' - 6 5/8"

2

CASUAL/ TAILORED SHOP 03

HOLD

7' - 0"

LOUNGE 04

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

ENTRY 01

6

15' - 4 3/4"

A-303

20' - 2 3/4"

ABV.

19' - 2 1/4"

18' - 0 5/8"

4 TYP.

19 2

14

ALIGN

24' - 2 3/4"

A

CASE ENGINEERING, INC. 7

EX-01 2' - 11"

D

MEP ENGINEER

RETAIL TENANT

TYP.

3' - 0"

1

LEASE LINE TO LEASE LINE

4"

18

1' - 10 1/2" 2 1/2"

5 1/8"

10" 7' - 0"

6

B

TYP.

20' - 10"

A-305

14

8

6' - 0"

4

D

9

14

C

HOLD

EX-02

ALIGN

04 24

3' - 0"

17

ALIGN

2

8"

2 1/2"

21

6' - 6"

4

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1' - 6"

DOOR

EX-03

A-304

4"

23

7' - 4"

11

4' - 10"

22

8

3' - 0"

V.I.F.

E 12

LEASELINE TO LEASELINE

18

TYP.

OWNER'S REPRESENTATIVE

9

5

27' - 4"

14

6' - 7 1/8" HOLD

HOLD

2' - 6" 20

3' - 7 1/2"

3' - 4 1/4"

1' - 8 3/8" 3 5/8"

15

5' - 7"

1' - 9"

2 A-501

NORTH

CONSTRUCTION PLAN SCALE: 1/4" = 1'-0"

CONSTRUCTION PLAN SYMBOL / HATCH SYMBOL / HATCH

DESCRIPTION EXISTING PARTITION TO REMAIN

NEW PARTITION

SOUND RATINGS REQUIREMENTS GENERAL NOTES: 1. ALL PENETRATIONS INTO SOUND RATED PARTITIONS OR FLOOR-CEILING ASSEMBLIES SHALL BE SEALED, LINED, OR INSULATED WITH AN APPROVED PERMANENT RESILIENT SEALANT.

1. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLAN(S) AND EXISTING CONDITIONS.

2. ALL RIGID CONDUITS, DUCTS, PLUMBING PIPES, AND APPLIANCE VENTS LOCATED IN SOUND RATED ASSEMBLIES SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES, MOUNTS, OR A MINIMUM 1/4" THICK APPROVED RESILIENT MATERIAL.

2. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER.

3. AN APPROVED PERMANENT AND RESILIENT ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR AND THE SEPARATION WALLS.

ROOM NAME 01

ROOM TAG

101

DOOR TAG

4. METAL VENTILATING AND CONDITIONED AIR DUCTS LOCATED IN SOUND RATED ASSEMBLIES SHALL BE LINED (EXCEPTION: DUCTS SERVING ONLY EXIT WAYS, KITCHEN COOKING FACILITIES, AND BATHROOMS NEED NOT BE LINED).

PARTITION TYPE TAG, REF. A-600

5. MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES WHENEVER A PLUMBING, PIPING, OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR BEYOND THE PIPE OR DUCT. THIS REQUIREMENT IS NOT APPLICABLE TO FIRE SPRINKLER PIPE, GAS LINE OR ELECTRICAL CONDUIT.

A

1 A-101

1 A-101

1 A-101

ELEVATION TAG

CONSTRUCTION PLAN GENERAL NOTES:

6. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24" AND NOTE THAT BACK AND SIDES OF BOXES SHALL BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKED BY A MINIMUM OF 2" THICK MINERAL FIBER INSULATION.

CONSTRUCTION PLAN KEY NOTES: 1

LEASE LINE

2

EXISTING 2-HR FIRE-RATED CMU DEMISING WALL TO REMAIN; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH

3

EXISTING METAL 2" FURRING PARTITION TO REMAIN; G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND PREP FOR NEW PAINT FINISH

4

EXISTING KNEE WALL AT STOREFRONT TO REMAIN; G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND PREP FOR NEW PAINT FINISH

5

EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION

6

EXISTING THRESHOLD AT STOREFRONT ENTRY TO REMAIN; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)

7

EXISTING STOREFRONT ENTRY DOOR AND HARDWARE TO REMAIN; G.C. TO PROVIDE NEW BESTLOCKS; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION; REF A-601 FOR DOOR AND HARDWARE SCHEDULE

3. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL OR COLUMN U.N.O. DO NOT SCALE DRAWINGS UNDER ANY CIRCUMSTANCES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER THE SCALE ON THE DWGS. 4. LL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. TO REMAIN MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP. 5. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING CONSTRUCTION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE.

STAMP

6. G.C. TO USE 5/8" TYPE 'X' GYPSUM BOARD THROUGHOUT PROJECT. 7. ALL OUTSIDE CORNERS AT DRYWALL PARTITIONS AND FURRING TO HAVE METAL CORNER BEADS. TAPE, PLASTER, AND SAND SMOOTH. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP.

7. NO WALL FURNACE SHALL BE INSTALLED IN SOUND RATED PARTITIONS.

DETAIL SECTION TAG

DETAIL CALLOUT TAG

8. NO ELECTRICAL PANEL SHALL BE INSTALLED IN SOUND RATED PARTITIONS.

8. ACCESS PANELS IN WALL / CEILING FOR PLUMBING, MECHANICAL, ELECTRICAL ACCESS SHALL BE FLUSH FRAMELESS SQUARE CORNER GYP. BOARD PANELS, SEE RCP A-102 FOR SPECIFICATION.

8

NEW PARTITION TO DECK; REF. A-600 FOR PARTITION SCHEDULE

9. CEILING ASSEMBLY TO MEET 50 51C AND 50 11C SOUND RATING REQUIREMENTS.

9. METAL STUDS SHALL EXTEND UP TO THE DECK ABOVE WHERE NOTED AND APPLICABLE.

9

NEW PARTIAL HEIGHT PARTITION; REF. A-600 FOR PARTITION SCHEDULE

10. PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADERS AND JAMBS, AND AS REQUIRED TO MAKE ASSEMBLY RIGID.

10

NEW WATER COOLER; COORD W/ PLUMBING DWGS.

11

NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN A.F.F. AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT/BRACING AS REQ'D ; COORD. WITH MEP DRAWINGS.

12

NEW MOP SINK AND FAUCET; REF TO A-101 FOR SPEC; COORD. W/ MEP DWGS; REF. ELEVATIONS

13

EXISTING RESTROOM TOILET AND SINK BY LANDLORD; COORD. W/ MEP DWGS.

12. FOR ALL WOOD MEMBERS REQUIRED BY CODE TO BE FIRE-RETARDANT TREATED, PROVIDE PRESSURE IMPREGNATION WITH FIRE-RETARDANT CHEMICALS TO PROVIDE UL PRS FIRE HAZARD CLASSIFICATION. ALL SUCH WOOD MEMBERS SHALL BE IDENTIFIED WITH A UL LABEL.

14

G.C. TO PROVIDE FRT PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND FIXTURE CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION

13. G.C. TO COORD. NEW WORK W/ RCP.; REF. A-102 RCP FOR SOFFIT / LIGHTING INFORMATION.

15

G.C. TO USE MOISTURE-RESISTANT TYPE "X" GYP. BOARD AT THE WALLS IN WET AREAS, INCLUDING AROUND THE VICINITY OF THE MOP SINK, TYP.

16

15. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS.

G.C. TO PROVIDE PLASTEX POLYWALL WATERPROOF PANEL UP TO 48" AFF BEHIND AND AROUND MOPSINK, REF. ELEVATIONS; REF. A-104 FOR SPEC.

17

EXISTING ELECTRICAL PANEL TO REMAIN; G.C. TO RE-CIRCUIT AS REQ'D; COORD. W/MEP DWGS

16. FIRE EXTINGUISHERS SHALL BE INSTALLED AS REQ'D BY LOCAL AUTHORITY HAVING JURISDICTION.

18

EXISTING 1-HR FIRE-RATED DEMISING WALL; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH

19

EXISTING SUSPENDED AHU ABOVE; COORD. W/ MEP DWGS

20

INFILL AT BACK WALL TO BE EXISTING BY LANDLORD

21

G.C. TO SUSPEND EXISTING TRANSFORMER ABOVE; COORD. W/ ELECTRICAL AND STRUCTURAL DWGS

22

G.C. TO RELOCATE EXISTING DISCONNECT SWITCH NEXT TO NEW SWITCH; COORD. W/ MEP DWGS

23

G.C. TO PROVIDE NEW DISCONNECT SWITCH; COORD. W/ MEP DWGS.

24

NEW CUSTOM DOOR FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE SILENCERS AND MIRROR; G.C. TO COORD. ROUGH OPENING DIMENSIONS WITH APPROVED FINAL SHOP DWGS.

11. G.C. SHALL SUPPLY AND INSTALL PROPER AND ADEQUATE BLOCKING TO SUPPORT ALL OWNER SUPPLIED AND MILLWORK APPLIED/INSTALLED ITEMS FOR FIRM, LEVEL, AND SECURE INSTALLATION OF SUCH ITEMS ON WALLS, COLUMNS, ETC. IF REQUIRED BY CODE ALL SUCH BLOCKING AND SUPPORTS SHALL BE FIRE RETARDANT TREATED TO MEET SUCH REQUIREMENTS. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE IN COMPLIANCE WITH IBC SECTION 2304.9.5.

14. G.C. TO COORD. NEW WORK W/ FIXTURE PLAN. REF. A-101 FIXTURE PLAN FOR FIXTURE INFORMATION.

17. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING - CREATED OR EXPOSED DURING CONSTRUCTION,PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 18. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UL STANDARDS FOR THROUGH PENETRATION FIRESTOP SYSTEMS. THE G.C. SHALL SUBMIT SHOP DRAWING DETAILS THAT THE INSPECTOR MAY REQUIRE. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES CLEARLY DEFINED. 19. ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING THERMAL INSULATION - CREATED OR EXPOSED DURING CONSTRUCTION - SHALL BE RESTORED TO FULL CAPACITY. 20. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

C 10 3/4"

ADA RESTROOM 07

4 A-306

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

CONSTRUCTION PLAN

A-100


ARCHITECT

61' - 10"

PL.05 PL.04

2

UH

CAB

B EQ

3

A

EQ 1

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

MR PL.01

FB-01

8

A.03

10

3'

4

F.12

TYP.

5 10

3' - 0"

3' - 0"

A.02

SO

MIN.

3' - 0"

F.21

F.06

4

10

7

FE

MQ

MQ

HS

11

F.23 ABV.

12

A.03 MQ

F.03

F.01

A.05

STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

10

F.01 1

6"

ADA FITTING ROOM 05

6' - 0"

F.11A

MQ

A.04

BENCH

5

SB

F.11

FB-01

LICENSE # C-4550

DISPLAY WINDOW 02

2' - 4 1/8" VIF

CT

4

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

MQ

3' - 1"

A.05

CASE ENGINEERING, INC. ENTRY 01

F.06

CPT-01

3' - 0"

TYP.

F.11A

2" 1/3 1 -

5

4

BS

CPT-02

LEASE LINE TO LEASE LINE

LOUNGE 04

MEP ENGINEER

20' - 10"

REF-1

8

F.01

V.I.F. PLATFORM

A.04

5

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

9' - 0 7/8"

TDSH

9' - 0"

F.22

A.05

FDSK

MIN

1

F.16

TYP.

F.19

F.06

CASUAL/ TAILORED SHOP 03

BS CH-1

CB

10"

MIN.

FB-01

4

1"

5

F.15

F.03

3' - 0"

F.22

A.05 CH-1 A.04

4

F.01

3' - 2 1/4"

4' - 0"

3 A-400

9

F.01

3' - 9"

1' - 0 1/2"

A.01

5

PL.06

EQ

D.08

6

KB

EQ.

TYP.

EQ

SH16 BR B16 SHBH SHB

EQ

3' - 9"

2' - 4"

4 5

SH16

EL

1

10"

4 TYP.

REF-2

BOH 08

OWNER'S REPRESENTATIVE

F.01

VESTIBULE 06

TPH

4' - 8" 14

PL.03

GB

5

SD TD

3' - 2 13/16 "

2' - 4"

PL.02

RETAIL TENANT

FE

4

EQ

NORTH TYP.

EQ

6"

2' - 6"

1

V.I.F.

FIXTURE PLAN SCALE: 1/4" = 1'-0"

FIXTURE PLAN SYMBOL / HATCH SYMBOL / HATCH

DESCRIPTION

EXISTING PARTITION TO REMAIN

NEW PARTITION ROOM NAME 01

X.01

ROOM TAG

FIXTURE TAG

FIXTURE PLAN GENERAL NOTES: 1. REFER TO FINISH SCHEDULE A-104 FOR FINISH DESCRIPTIONS AND SPECIFICATIONS. 2. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES. 3. G.C. & F.C. TO COORDINATE CONSTRUCTION & INSTALLATION MATERIALS, METHODS, AND SCHEDULING OF FIXTURES. 4. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS. 5. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP. 6. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING. G.C. TO COORDINATE WITH SHOP DRAWINGS TO BE PROVIDED BY THE FIXTURE CONTRACTOR. 7. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS. 8. FINISHES TO BE FIRE RATED AS REQUIRED BY STATE/LOCAL BUILDING CODES. 9. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND MILLWORK. COORDINATE CONSTRUCTION DETAILS AND DIMENSIONS WITH FIXTURE PLANS AND FIXTURE SHOP DRAWINGS. 10. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES. 11. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS. 12. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES. 13. THERE ARE NO POINT-OF SALES OR SERVICE COUNTERS IN THIS STORE. RETAIL TENANT STORES ARE DESIGNED AND OPERATE AS SHOWROOMS. MO MERCHANDISE IS SOLD ON LOCATION.

FIXTURE SCHEDULE TAG

DESCRIPTION

DIMENSION

RESPONSIBILITY

MANUFACTURER / MODEL

FINISH

QTY.

A.01

3-WAY MIRROR

62"W x 1 1/2"D x 90"H

F.C./G.C.

F.C./G.C.

GL-02 / MT-01

1

A.02

FLAT MIRROR

24"W x 72"H

F.C./G.C.

F.C./G.C.

GL-02 / MT-01

1

A.03

TALL FLAT MIRROR

24"W x 78"H

F.C./G.C.

F.C./G.C.

GL-02 / MT-01

2

A.04

FITTING ROOM HANG BAR

A.05

VALET PEG

FIXTURE PLAN KEY NOTES:

EQUIPMENT SCHEDULE

1" SQ. x 3"D x 30"L w/ 2 1/2" SQ. MOUNTING PLATES 1" SQ. x 3"D HOOK w/ 2 1/2" SQ. MOUNTING PLATE

F.C. F.C.

F.C.

MT-01

F.C.

MT-01

4 15

F.01

LADDER FIXTURE - TYP.

62"L x 18"W x 81"H

F.C.

F.C.

MT-01 / WD-01

6

F.03

FREE-STANDING SHELF

133 1/2"L x 24"W x 67 1/2"H

F.C.

F.C.

MT-01 / WD-01

2

F.06

FREE-STANDING RACK

24"W X 38"L X 63"H

F.C.

F.C.

MT-01

4

F.10

MANNEQUIN RISER

18"L x 14"W x 12 1/4"H

F.C.

F.C.

WD-01

2

F.11

NESTER TABLE

67 1/2"L x 24"W x 28"H

F.C.

F.C.

WD-01

1

F.11A

NESTER CUBE

30"L x 30"W x 18"H

F.C.

F.C.

WD-01, MT-01

2

F.12

ADA BENCH

42"L x 20"W x 17"H

F.C.

F.C.

WD-01

1

F.15

UNDERWEAR FIXTURE

29"L x 16"W x 30"H

F.C.

F.C.

WD-03, MT-01

1

F.16

BAR

60"L x 33"W x 39"H

F.C.

F.C.

WD-03

1

F.19

SMALL TABLE

66"L x 30"W x 30"H

F.C.

F.C.

WD-02

1

F.21

SMALL ROUNDER

42"Ø x 30"H

F.C.

F.C.

WD-03

1

F.22

FITTING ROOM UNIT

REF. PLANS

F.C.

F.C.

MT-01 / WD-01

2

F.23

DISPLAY PLATFORM

REF. PLANS

F.C.

F.C.

WD-01

1

NOTES / REMARKS

FINISH: GL-02, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-02) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC FINISH: GL-02, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-02) BY G.C.; VERIFY DIMS. FINISH: GL-02, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-02) BY G.C.; VERIFY DIMS. FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. FINISH: MT-01 ; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01, WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01, WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; RIGHT SIDE MOUNTED FINISH: WD-03, MT-01 FINISH: WD-03 (WALNUT); REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-02 (HICKORY); REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-03 (WALNUT); REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01, WD-01; G.C. TO CONFIRM FIELD DIMENSIONS AND COORD. W/ F.C. FINISH: WD-01 (WHITE OAK); REF. FIXTURE PACKAGE FOR MORE DETAILS

TAG

DESCRIPTION

DIMENSION

RESPONSI BILITY

MANUFACTURER

MODEL

FINISH

QTY.

16"

G.C.

THE CONTAINER STORE

ELFA WHITE VENTILATED SHELF BRACKETS

WHITE METAL

19

WALL MOUNTED SHELVING BRACKET WALL MOUNTED STANDARD TOP TRACKS WALL MOUNTED STANDARD

VARIES

G.C.

THE CONTAINER STORE

ELFA HANG TOP TRACKS

WHITE METAL

8

84"H

G.C.

THE CONTAINER STORE

ELFA HANG STANDARD

WHITE METAL

19

CB

COAT HANG BAR

20"L X 1 3/8"D X 2 3/4"H

G.C.

EL

EMPLOYEE LOCKER FOLDING WALL MOUNTED DESK

12"W x 18"D x 72"H

G.C.

THE CONTAINER STORE - UMBRA; ULINE

36"L X 18"D X 30"H

G.C.

IKEA

FLIP HOOK BAR; SKU : 10054165 H-1845GR BJURSTA WALL MOUNTED DESK

REF. PLANS; G.C. TO CUT LENGTHS IN FIELD AS REQ'D

G.C.

ARAKAWA

CRB 1800-A

G.C.

MMF INDUSTRIES

201202889

F.C./G.C.

FAGOR

MODEL BC-112

G.C.

DANBY

G.C.

B16 BR BST

FDSK HS KB REF-1 REF-2 SH16 SHB SHBH

HANGING SYSTEM MERCHANDISING TRACK KEY BOX SALES FLOOR REFRIGERATOR BOH REFRIGERATOR

11.7"H x 7.9"W x 3.6"D 23 1/2"W x 23 1/2"D x 34"H 20 5/8"W x 20 7/8"D x 32 3/4"H

WALL MOUNTED 16"D (LENGTH VARIES) VENTILATED SHELF WALL MOUNTED SHELVING 36"L, 48"L HANG BAR HANG BAR HOLDER 3"H X 2"D

COORD. INSTALL WITH BOH SHELVING

THE CONTAINER STORE

ELFA WHITE VENTILATED SHELVES

WHITE METAL

8

G.C.

THE CONTAINER STORE

ELFA CLOSET ROD

WHITE METAL

8

G.C.

THE CONTAINER STORE ELFA CLOSET ROD HOLDER WHITE METAL BLACK STATIC VIDEO MOUNT VENTED DATA SHELF RESISTANT PRODUCTS VMP-ER-S2UV POWDER COAT CASABELLA - GROOK BLACK/ALUMIN UTILITY HOLDER; SKU : THE CONTAINER STORE UM 10055909

16

TDSH

TELE/DATA SHELF

19"L x 14 3/4"D x 4"H

G.C.

UH

UTILITY HOLDER

10"L x 4"D x 2 3/4"H

G.C.

FITTING ROOM STOOL

16"W x 16"D x 30"H

CPT-02

WALK-OFF MAT

36"W X 72"L X 3/8"H

CT

COFFEE TABLE

60"L x 19"D x 14"H

FB-01

FITTING ROOM CURTAIN

REF. PLANS

MQ

MANNEQUIN

3/4 MALE TORSO

SB

SUITING BENCH

48"L x 19"D x 14"H

SO

SOFA

86"L X 36"D

1

NOT INSET; REMOVABLE AREA RUG

CATALINA OLEFIN - 1462-M-36 THK CHARCOAL --

1

NOT INSET; REMOVABLE WALK-OFF MAT

BRAD JOBE

3

TBD

9

G.C. TO COORD. INSTALLATION W/ BRAD JOBE; CURTAIN SUSPENDED FROM RODS AND RINGS -

--

1

FINISH TBD

--

1

PL.04

SERVICE SINK

PL.05

SERVICE SINK FAUCET

PL.06

WATER COOLER

1

DIMENSION 20 1/2"W X 18 1/4"D

RESPONSI BILITY MANUFACTURER LANDLORD AMERICAN STANDARD

CH-1

TBD

1

LEASE LINE

2

NEW MOP SINK AND FAUCET; COORD. W/ MEP DWGS.

3

EXISTING RESTROOM PLUMBING FIXTURES AND ACCESSORIES TO REMAIN; COORD. W/ MEP DWGS. G.C. TO PROVIDE NEW WALL MOUNTED CABINET

4

G.C. TO PROVIDE FIRE RATED PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND FIXTURE CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION.

5

NEW B.O.H. CONTAINER STORE ELFA SHELVING; G.C. TO COORD. INSTALLATION W/ MANUFACTURER; G.C. TO VERIFY SITE DIMENSIONS AND SUBMIT A PROPOSED LAYOUT FROM THE CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION.

6

NEW TELE/DATA BOARD BY G.C. (3/4" FRT PLYWOOD) MOUNTED TO WALL AT B.O.H. AND PAINTED TO MATCH ADJ. FINISH

7

NEW DRAPERY PANEL INSTALLED ON TAPED-IN RECESSED CURTAIN TRACK AT ADA FITTING ROOM OPENING; B.O. OPENING AT 7'-0" AFF; FINISH TRACK WHITE; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS

8

NEW DRAPERY PANEL INSTALLED ON RODS AND RINGS AT FREE-STANDING FITTING ROOMS; RODS AND RINGS TO BE INSTALLED DURING ASSEMBLY OF FREE-STANDING FITTING ROOM FIXTURES (F.22); G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS

9

3-WAY MIRROR (A.01) W/ LIGHTING ABOVE; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; G.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND RCP

10

MIRROR (A.03); B.O. FRAME MOUNTED @ 10" AFF; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; G.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS.

11

MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD, REF. A-102B FOR DIMENSIONS; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.

STAMP

PROVIDE END CAPS AS REQ'D

1 1

PLUMBING SCHEDULE

DIMENSION 15"Ø x 27"H

120"W x 96"L

3

1

DESCRIPTION BAR STOOL

AREA RUG

MATCH ADJ. PT-01C

BLACK

TAG BS

CPT-01

1

DCR044A2BDD

PL.03

2

WHITE

COORD. INSTALL WITH BAR F.16

ADDITIONAL FURNITURE / FIXTURE SCHEDULE

--

1

1

EXISTING RESTROOM SINK 2 "W X 5 1/2"D X 6 3/4"H LANDLORD AMERICAN STANDARD SELECTRONIC 6055.102 FAUCET EXISTING RESTROOM 17 1/2"W X 30 5/8"D X 30 LANDLORD AMERICAN STANDARD ASTUTE VORMAX 727AA.121 TOILET 11/16"H

NOTES / REMARKS

GRAY

1

PL.02 QTY. 3

-

PUTTY BLACK/ALUMIN UM

DESCRIPTION EXISTING RESTROOM SINK

MANUFACTURER --

1

COORD. INSTALL WITH BOH TELE/DATA BOARD; REF. ELEVATIONS CEILING RECESSED MERCHANIDISING TRACKS; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND POWDERCOAT TO MATCH ADJ. FINISH COORD. W/ TELE/DATA BOARD

TAG PL.01

RESPONSIBLITY OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT)

NOTES / REMARKS

MODEL LUCERNE 0356.041

FINISH WHITE

CHROME

QTY NOTES / REMARKS EX G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. EX COORD. W/ MEP DWGS.

WHITE

21"W X 21 1/2"D X 44 1/2"H 8" SPREAD

G.C.

TURBO AIR

TSA-1MOP

G.C.

B-0674-RGH

11 3/4"W x 14 1/2"D x 50"H

G.C.

T&S BRASS AND BRONZE WORKS, INC. QUENCH

STAINLESS STEEL CHROME

Q7 FREESTANDING

BLACK

EX G.C TO SPECIFY RIGHT HANDED LEVER; G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS. 1

COORD. W/ MEP DWGS.

1

COORD. W/ MEP DWGS.

12

NEW STOREFRONT DISPLAY PLATFORM (F.23) BY F.C.; G.C. TO VERIFY SITE DIMENSIONS AND COORD. INSTALL W/ F.C.

13

NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN. A.F.F. AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT OR BRACING AS REQUIRED; COORD. WITH MEP DRAWINGS.

14

EXISTING ELECTRICAL PANEL TO REMAIN; G.C. TO RE-CIRCUIT AS REQ'D COORD. W/ MEP DWGS

DESCRIPTION WALL CABINET

CH

COAT HOOK

GB

EXISTING ADA GRAB BARS

MR

EXISTING RESTROOM MIRROR

SD TD TPH

DIMENSIONS 23.2"W x 12.2"" x 23.4

RESPONSIBILITY G.C.

MANUFACTURER TOPEAKMART

MODEL 23" x 23" 2 DOOR WALL MOUNT CABINET

FINISH WHITE

1 1/4" W x 1 1/8" D x 1 1/4" H 18"L, 36"L, 42"L

LANDLORD

BOBRICK

B-233

LANDLORD

BOBRICK

B-6806-18, B-6806-36, B-6806-42

18"W X 36"H

LANDLORD

BOBRICK

B-165 1836

STAINLESS STEEL POLISHED STAINLESS STEEL BRUSHED STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL CHROME

EXISTING SOAP 6 1/8"L x 7"W x 3 5/16"D DISPENSER EXISTING RECESSED 19"H X 13"W X 4 1/4"D PAPER TOWEL DISPENSER EXISTING TOILET PAPER 6"W X 4 1/4"D X 2 3/4"H HOLDER

LANDLORD

BOBRICK

B-4112

LANDLORD

BOBRICK

B-35903

LANDLORD

BOBRICK

B-264

QTY NOTES / REMARKS 1 FINISH: WHITE; G.C. TO PROVIDE AND INSTALL, CENTERED ABOVE W.C. AT 4'-3" AFF EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS

EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX RECESSED INTO WALL EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: JO CHECKED BY: Checker AREA: 1,400 SF

#

RESTROOM ACCESSORIES SCHEDULE TAG CAB

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

C

LEASE LINE TO LEASE LINE

ADA RESTROOM 07

13

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

FIXTURE PLAN FIXTURE CONTRACTOR SPECIAL ITEMS: F.22 ?

FREE-STANDING FITTING ROOM (x2)

D.04 ?

DECORATIVE CEILING SLATS

F.23 ?

DISPLAY PLATFORM (x1)

? D.08

MIRRORED DOOR CUSTOM (x1); G.C. TO COORD. ROUGH OPENING W/ APPROVED SHOP DWGS

A-101

DATE 02/27/2019 03/04/2019


ARCHITECT

61' - 10" LEASE LINE TO LEASE LINE VESTIBULE

06

7' - 0" AFF

07

9' - 0" AFF

GYP. BOARD

9' - 0" AFF

GYP. CEILING

PT-01A

GYP. CEILING

23

27

27

TYP.

20

R-2

23 24 FL-1 25

TYP.

28

WD-02

B.O. EX'G SLAB

R-2 DC 25

P-3

9

S2

6

SD

F-2A

TYP.

F-2B

F-2A

17

F-2A

F-2B

EM-1

WP

CLG

CLG

F-2B F-2A F-2A

22

R-2

F-2B

F-2A F-2A

28

26

TYP.

TYP.

P-1 F-2B

22

CLG

F-2A F-2A

17

F-2B F-2A

F-2B F-2A

F-2A

FL-1

P-1 F-2A

F-2B F-2A

CLG

27

S1

33

TYP. R-2

R-2

R-2

CLG

23

OS

LS

4 A-501

T-01

R-2

EM-1

R-2

25

30

R-2

TYP.

STRUCTURAL ENGINEER

29

11' - 0" AFF

LS

TM

GYP. CEILING PT-01C

R-2

GB CLG

F-1 F-1 TR-1 F-1 F-1

MD CLG

TYP.

DC EXG-EM

01

12

S1 27

SM-1

16

F-2B

LICENSE # C-4550

DC

ENTRY

1

17 F-2A

EX'G MTL PANEL

18

EM-1

TR-2

8

TYP. ST

R-2

HS

17

F-2A F-2B F-2A

19

16

F-2B F-2A F-2A F-2B

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

8' - 2" V.I.F

EX-1

SD P-1

TYP.

CASE ENGINEERING, INC.

ENTRY VEST. SOFFIT

EX'G

13

P-1

CH-1 25

TC1

TR-2

2 R-2

P-1

27

16

F-2A

TR-2

TYP.

S2

17

21

P-1

J D

S

F-2B

32

TYP.

CLG

R-2

17

TC2

FL-1 P-3 6

MEP ENGINEER

10

R-2

S

CLG

A-502

1

P-2

R-2

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

4

3 A-502

S1

27

TYP.

TYP.

BLACK

5

S

32

19' - 9" V.I.F

CLG

11

ABV.

B.O. BEAMS

SD

SD

14

DC

B.O. TRACK

3 A-501

SD

ST

34

TYP.

03

OWNER'S REPRESENTATIVE

PT-02

EM-1

EX-2

SD

11' - 9" AFF

25

SD

23

CLG

13' - 3" AFF

TYP. TYP.

TYP. ST

WOOD BEAMS CASUAL/ TAILORED SHOP

TRACK LIGHTS

15

F-1 CLG

D D D

F-1

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

EXISTING LANDLORD CEILING BELOW

2

F-1

31

OSBORN

A-502

10

F-1

CLG CLG CLG

RETAIL TENANT

7

4

EXG-EX

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

PT-01C

3

26

A

LEASE LINE TO LEASE LINE

PT-01C

B

LIGHT COVE 11' - 5" AFF GYP. CEILING PT-01C

1

BOH

ADA FITTING ROOM

08

05

19' - 9" V.I.F

11

11

LOUNGE SHOP

WALL WASHER COVE

SALES CEILING

1

7' - 0" AFF

04

11' - 8" AFF

11' - 0" AFF

A-501

9' - 0" AFF

GYP. BOARD

11' - 0" AFF

GYP. CEILING

GYP. CEILING

B.O. EX'G SLAB

GYP. CEILING

PT-01A

GYP. CEILING

PT-01C

PT-01C

PT-02

PT-01C

ADA FR TRANS

1 NORTH

PT-01C

REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0"

REFLECTED CEILING PLAN SYMBOL / HATCH LEGEND HATCH / SYMBOL

SYMBOL

ROOM NAME 01 TYPE FINISH 0'-0" AFF SYMBOL

S CLG

WHITE

SUPPLY GRILLE

WHITE

REF. MEP

NEW PARTITION

EXHAUST FAN & GRILLE

WHITE

REF. MEP

EM-1

ROOM TAG

ACCESS PANEL

WHITE

X V.I.F.

SURFACE RECESSED EMERGENCY LIGHT

EX-1

1" TAPED-IN LINEAR SLOT

WHITE

REF. RCP

EX-2

LS HS DESCRIPTION FIRE ALARM SPEAKER/STROBE CEILING SUSPENDED PROVIDE STEM KIT; REF. MEP FOR REQ'D CANDELA RATINGS

MATCH ARAKAWA HANGING TRACK ADJ. NOTE FINISH REF. MEP AND APPROVED WHITE FIRE ALARM DWGS MOUNT AT VISIBLE HEIGHT

REF. RCP QTY 1

REF. MEP AND APPROVED FIRE ALARM DWGS MOUNT AT 96"AFF (MAX)

WHITE

2 EXG

ST CLG

FIRE ALARM STROBE CEILING MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS

REF. MEP AND APPROVED FIRE ALARM DWGS

WHITE

3

SD

SMOKE DETECTOR

REF. MEP DWGS

WHITE

5

SECURITY CAMERA, SURFACE MOUNTED

COORD. W/ SECURITY VENDOR

MATCH ADJ.

5

OS

OCCUPANCY SENSOR, WIRELESS CEILING MOUNTED

REF. MEP DWGS

WHITE

1

MD

MOTION DETECTOR WIRELESS

COORD. W/ SECURITY VENDOR

WHITE

1

GB

GLASS BREAK WIRELESS

COORD. W/ SECURITY VENDOR

WHITE

1

DC

DOOR CONTACT WIRELESS

COORD. W/ SECURITY VENDOR

MATCH 2 @ 2 ADJ. ENTRY 1 @ BOH

FLUSH CEILING SPEAKER

COORD. W/ A/V VENDOR

WHITE

2

20A GROUNDED DUPLEX CEILING OUTLET

REF. MEP DWGS

WHITE

2

J CLG

CEILING MOUNTED J-BOX

REF. MEP DWGS

MATCH ADJ.

11

D CLG

ABOVE CEILING DRIVER FOR STOREFRONT SIGNAGE/ LED TAPE LIGHT

COORD. W/ SIGNAGE VENDER

N/A

4

TC1

CLG TC2

CLG

WHITE

1

TRAFFIC COUNTER SECONDARY UNIT

COORD. W/ RETAILNEXT

WHITE

1

WIRELESS ACCESS POINT; PAINT TO MATCH ADJACENT FINISH

REF. APPROVED SPRINKLER DWGS REF. APPROVED SPRINKLER DWGS AS PER VENDOR DWGS (BANDWAVE)

WHITE U.N.O. WHITE U.N.O. N/A

W/V 100W

QUANTITY COMMENTS 1 CHANDELIER PROVIDED BY OWNERS (RETAIL TENANT); G.C. TO PROVIDE 2700K FROSTED LED LAMPS; VERIFY WITH RETAIL TENANT EXACT TYPE PRIOR TO PURCHASE

1. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT UNLESS OTHERWISE NOTED. 2. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SUBMIT PLANS FOR MODIFICATION OF THE FIRE SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE THE TENANT SPACE. SUBMIT SHOP DRAWINGS TO THE LANDLORD, OWNER, AND ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL.

EVENLIGHT-APERION

APR-25-LC-UI

WHITE

25W

5

G.C. TO PAINT TO MATCH ADJ. FINISH

3. ALL FINISHING AND PAINTING REQUIREMENTS SHALL BE AS PER THE FINISH SCHEDULE, INTERIOR ELEVATIONS, AND SPECIFICATIONS.

RECESSED CEILING MOUNTED EXIT SIGN AT SALES

CONTECH

REXA-SF-R-EM-C-P

WHITE

120/277 V

1

SINGLE FACE, RECESSED CEILING MOUNTED

4. ALL LIGHT FIXTURES, INCLUDING EXIT LIGHTS, EMERGENCY LIGHTS, ETC., SHALL BE FURNISHED BY OWNER AND INSTALLED BY THE CONTRACTOR, EXCEPT THE G.C. SHALL PROVIDE AND INSTALL THE LAMPS FOR THE SM-1 AND P-1 FIXTURES.

RECESSED WALL MOUNTED EXIT SIGN AT SALES

CONTECH

REXA-SF-R-EM-C-P

WHITE

120/277 V

1

SINGLE FACE, RECESSED WALL MOUNTED

5. THE CONTRACTOR SHALL USE A LASER LEVELING DEVICE FOR THE LEVELING OF ALL SOFFITS, CEILINGS, AND SUSPENDED GRIDS, TYPICAL. 6. THE ELECTRICAL CONTRACTOR IS TO VERIFY THAT THE EXISTING SERVICE IS ADEQUATE FOR THE DESIGN LOADS. IF NOT, NOTIFY THE ARCHITECT AND MEP ENGINEER IMMEDIATELY.

EXG

EXG

EXG

12W

1

EXTERIOR LED EM LIGHT

EXG-EX

WALL MOUNTED EXIT SIGN AT BOH

EXG

EXG

WHITE

120/277 V

1

EXISTING EXIT SIGN / EMERGENCY LIGHT COMBO TO REMAIN

WHITE

18W

8

GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY

9. ALL VENDORS TO BE COORD. BY G.C.

BLACK

18W

20

GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY

10. KEEP ALL NEW COMPONENTS MOUNTED AS HIGH AS POSSIBLE IN EXPOSED CEILING

BLACK

18W

13

GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY

11. ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT CONCEALED WHERE POSSIBLE.

F-2B

FL-1 P-1

12

9 1

MINI HORIZONTAL TRACK LIGHT FIXTURE MINI HORIZONTAL TRACK LIGHT FIXTURE MINI HORIZONTAL TRACK LIGHT FIXTURE

4' SUSPENDED LINEAR LED CEILING PENDANT LIGHT- 20"

AMERLUX-HORNET HIGH POWER AMERLUX-HORNET HIGH POWER AMERLUX-HORNET HIGH POWER

HORNET-HP-H-A14-18-LED-WTTJ1-120-SP-3000-97 HORNET-HP-H-A14-18-LED-BTTJ1-120-SP-3000-97 HORNET-HP-R/SR-FRAME-1-LE D-120 / HORNET-HP-R-TRIM-A14-2-18LED-BT-120-277-MFL-BT-3000-9 7 MERCURY LIGHTING LSA-4-4000-35K-HTA-U55-UNI

P-2

ALINEA LINEAR WALL SCONCE

AAMSCO

THE WESCO BLE-C-VDBW20-PC-975 W/ NARROW VENT SLOTS AND 8'-0" BLACK CORD LED100SYM-24K-BE

P-3

ALINEA LINEAR WALL SCONCE

AAMSCO

LED50SYM-24K-BE

BARN LIGHT ELECTRIC

P-4

ALINEA LINEAR WALL SCONCE

AAMSCO

LED50SYM-24K-PC

R-1

3"Ø DIMMABLE LED RECESSED DOWNLIGHT SEMI-RECESSED LIGHT WITH 2-TRACK HEADS

SOLAIS LIGHTING

XR3NC-D-XM20-30K-1450-WH/ WH HORNET-HP-R/SR-NC-FRAMET-2-120-LE/TE / HORNET-HP-SR-NC-TRIM-T-2-1 8-WT-120-277-MFL-MFL-309-LE/ TE FM17080

R-2

SM-1 T-01

COORD. W/ RETAILNEXT

PENDANT SPRINKLER HEAD WP

3

TRAFFIC COUNTER PRIMARY UNIT

CONCEALED SPRINKLER HEAD

FINISH TBD

EXISTING LED LANDLORD EMERGENCY LIGHT

F-2A

BLACK

CLG

MODEL TBD

EXG-EM

F-1

COORD. W/ A/V VENDOR REF. ELEVATIONS FOR MOUNTING HEIGHT

WALL MOUNTED SPEAKER

MANUFACTURER LANGLEY STREET

REFLECTED CEILING PLAN KEY NOTES: 10

DECORATIVE CEILING BEAMS BY F.C.; G.C. TO PROVED IN-WALL BLOCKING AT PERIMETER AND COORD. DELIVERY AND INSTALL

11

CONTINUOUS 1" TAPED-IN LINEAR SLOT DIFFUSER; COORD. W/ MEP DWGS, TYP.

12

HS - MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.

13

EXIT SIGNAGE: RECESSED CEILING MOUNTED; COORD. W/ ELEVATIONS.

14

EXIT SIGNAGE EM LIGHT COMBO EXISTING TO REMAIN: SURFACE WALL MOUNTED; COORD. W/ ELEVS.

15

SURFACE MOUNTED TRACK LIGHTING IN LIGHT COVE; FINISH WHITE; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE; REF. A-501 CONSTRUCTION DETAIL; COORD. W/ MEP DWGS.

16

SUSPENDED TRACK LIGHTING ABOVE DECORATIVE BEAMS; FINISH BLACK; COORD. W/ MEP DWGS.

17

NEW SUSPENDED PENDANTS CORD HUNG, MOUNT B.O. PENDANT @ 8'-8", VERIFY IN FIELD; G.C. TO PROVIDE FROSTED 60W INCANDESCENT LAMPS; 2700K

18

NEW RETAIL TENANT LOGO: 15"H COLORED LED ILLUMINATED NEON LOOK LETTERS. EACH LETTER TO HAVE INDIVIDUAL WHITE METAL BACKS. EACH LETTER TO BE ENCLOSED IN INDIVIDUAL, NON REFLECTIVE CLEAR ACRYLIC BOXES. G.C. TO SUSPEND EACH SIGN BOX FROM INTERIOR CEILING AT TWO POINTS WITH LETTERS CENTERED IN THE WINDOW. G.C. TO PROVIDE CONCEALED J-BOX AND ACCESS AT INTERIOR. COORDINATE INSTALL AND LOCATION WITH SIGNAGE VENDOR. SIGNAGE TO BE CONTROLLED BY 24/7 PROGRAMMABLE TIME CLOCK. SIGNAGE FILED UNDER SEPARATE PERMIT

19

G.C. TO PROVIDE 12" x 12" ACCESS PANEL (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR SIGNAGE DRIVER ACCESS, COORD. EXACT LOCATION W/ MEP DWGS AND SIGNAGE VENDOR.

20

EXG. EXHAUST FAN AND GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR

21

PAINT-GRADE INTERNALLY INSULATED SPIRAL STEEL DUCTING AT EXPOSED SALES AREAS; G.C. TO PAINT TO MATCH ADJACENT CEILING COLOR; COORD. W/ MEP DWGS. NEW SUPPLY GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR.

7. ENSURE THAT ALL EQUIPMENT INCLUDES / BARES UL LABELS.

FIRE ALARM SPEAKER/STROBE WALL MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS

S2 CLG

DESCRIPTION CHANDELIER

RETURN GRILLE

S

S1

TAG CH-1

FINISH

EXISTING PARTITION TO REMAIN

QTY REF. MEP

SYMBOL

DESCRIPTION

DESCRIPTION

REFLECTED CEILING PLAN GENERAL NOTES:

LIGHTING SCHEDULE

SURFACE MOUNTED GLOBE LIGHT LED TAPE LIGHT

AMERLUX-HORNET HIGH POWER

SHADES OF LIGHT LEVITON

TR-1

SURFACE MOUNTED LIGHT TRACK

CONTECH

TAPE LIGHT: (3) TLT-12V-3-30K-16CR; 60W DRIVER: (3) TLP12VHW60-ENC; CHANNEL: (5) TLACA6 LT-P

TR-2

SUSPENDED LIGHT TRACK

CONTECH

LT-B

8. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTS; ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIELD FIRE INSPECTOR AT THE TIME OF THE FINAL BUILDING INSPECTION.

12. ACCESS PANELS IN CEILING MUST BE LOCATED TO PROVIDE ACCESS TO LANDLORD'S MECHANICAL EQUIPMENT PER LOCAL GENERAL GROWTH AUTHORITY.

WHITE

34W 60W

3 6

SUSPENDED FROM CEILING/DECK ABOVE @ 12'-0" AFF

GALVANIZED

B.O. PENDANT MOUNTED AT 8'-8" AFF; VERIFY IN FIELD WITH 60W FROSTED SOFT WHITE (2700K) INCANDESENT LAMPS

BLACK

11W

1

MTD. @ 7-10" AFF CENTERED ABOVE MIRROR

BLACK

7W

2

MTD. @ 7'-2" AFF CENTERED ON WALL

13. SPRINKLER HEADS AT GYPSUM BOARD CEILING MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING TILES WHERE APPLICABLE

REFLECTED CEILING PLAN GENERAL NOTES:

POLISHED CHROME WHITE

11W

1

17W

2

WHITE

36W

15

OLD BRONZE LED

60W 108W (3 x 36W / 12V)

1 1 24' - 10" VIF

MTD. @ 6-8" AFF CENTERED ABOVE MIRROR

1

LEASE LINE

2

EXISTING AHU BY LANDLORD ABOVE; G.C. TO SERVICE AND CONFRIM FUNCTIONS PROPERLY; COORD. W/ MEP DWGS.

3

SEMI-RECESSED CEILING MOUNTED

SURFACE MOUNTED; SOCKET FINISH: OLD BRONZE; CANOPY: OLD BRONZE; G.C. TO PROVIDE 60W E26 (MEDIUM BASE) SOFT WHITE (2700K) INCANDESCENT LAMPS REF. TO ARCHITECTURAL CEILING DETAILS FOR MOUNTING IN WASHER COVE; LENGTH: 24'-10" VIF CUT LED TAPE IN FEILD TO INSTALL IN 3 EQUAL LENGTHS

WHITE

120 V

REF PLANS 1 SURFACE MOUNTED TRACK; G.C. TO CUT LENGTHS PER RCP.

BLACK

120 V

3 TRACK SUSPENDED WITH AIRCRAFT CABLE AND HOLLOW STEM REF PLANS KIT AT POWER FEED LOCATIONS ONLY; G.C. TO CUT LENGTHS PER RCP.

NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN A.F.F. AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT/BRACING AS REQ'D ; COORD. WITH MEP DRAWINGS.

23

NEW SUPPLY GRILLE; COORD. W/MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR.

PROJECT NO.: 218259

24

DEMOLISH EXISTING ACT CEILING AND 2x4 LIGHT; PRIOR TO INSTALL OF NEW GYP. BOARD CEILING; (DEDUCT ALT: EXISTING ACT CEILING AND LIGHT TO REMAIN; CONFIRM WITH TENANT PRIOR TO DEMO)

DATE: 02/27/2019

25

NEW GWB CEILING @ ALL SALES / FITTING ROOM/ VESTIBULE LOCATIONS, TYP.

CHECKED BY: JSP

26

AREA OPEN TO EXISTING DECK ABOVE DECORATIVE TRELLIS AND @ ALL B.O.H. LOCATIONS, TYP; G.C. TO PAINT EXPOSED DECK PT-02; G.C TO ENSURE ASSEMBLY MEET 50 51C AND 50 11C

27

CONCEALED SPRINKLER HEAD W/ WHITE COVER; COORD. W/ MEP AND APPROVED SPRINKLER DWGS.

28

UPRIGHT SPRINKLER HEAD; COORD. W/ MEP AND APPROVED SPRINKLER DWGS.

5

NEW ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE MIRROR @ 7'-10" AFF; REF. ELEVATIONS; FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH.

29

EXISTING LANDLORD EM LIGHT TO REMAIN AT EXTERIOR SOFFIT BELOW

30

NEW LED TAPE LIGHT ABOVE IN COVE; CUT AND SPLICE LED STRIPS IN 3 EQUAL LENGTHS

6

NEW ALINEA LINEAR LIGHT FIXTURE; CENTER ON FITTING ROOM WALL @ 7'-2" AFF; REF. ELEVATIONS; FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH.

31

7

NEW ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE RESTROOM MIRROR @ 6'-8" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN POLISHED CHROME; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH

G.C. TO PROVIDE 12" x 12" ACCESS PANEL (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR LED TAPE LIGHT ACCESS ACCESS TO EXISTING LANDLORD BUILDING PIPES. G.C. TO VERIFY ON SITE REQUIRED SIZE AND CONFIRM LOCATION WITH RETAIL TENANT PRIOR TO INSTALL

32

NEW DRAPERY PANEL INSTALLED ON TAPED-IN RECESSED CURTAIN TRACK AT ADA FITTING ROOM OPENING; B.O. OPENING AT 7'-0" AFF; FINISH TRACK WHITE; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS

EXISTING DECK ABOVE IS 3 HOUR-RATED CONCRETE SLAB; IF FIRE PROTECTION IS DAMAGED, G.C SHALL RESTORE IT TO ITS ORIGINAL CONDITIONS AND FIRE PROTECTION RATING.

33

NEW DRAPERY PANEL INSTALLED ON RODS AND RINGS AT FREE-STANDING FITTING ROOMS; RODS AND RINGS TO BE INSTALLED DURING ASSEMBLY OF FREE-STANDING FITTING ROOM FIXTURES (F.22); G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS

G.C. TO PROVIDE 12" x 12" ACCESS PANEL (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR ACCESS TO EXISTING LANDLORD BUILDING PIPES. G.C. TO VERIFY ON SITE REQUIRED SIZE AND CONFIRM LOCATION WITH RETAIL TENANT PRIOR TO INSTALL

34

EXIT SIGNAGE RECESSED WALL MOUNTED

9

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

NEW RETURN GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR.

G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; COORD. W/ MEP AND STRUCT DWGS

8

STAMP

22

4

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

VEST. TRANS

20' - 10"

C

RESTROOM

DRAWN BY: RA, NK AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

REFLECTED CEILING PLAN

A-102


ARCHITECT

61' - 9 11/16" LEASE LINE TO LEASE LINE

C

B 44

18

GFI @ 46" AFF

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

W

6

OS

OWNER'S REPRESENTATIVE

35

CLG

9

SD

T

6

SD

S2

4

W

D D OS

9' - 6"

F

TM

F

CLG

17

29

S 35

CLG

32

29

21

S2

WP

CLG

CLG

CLG

J CLG

J

J

CLG

31

CLG

31

V

CP AV NM CG

14

@ 15" AFF

27

DC

CLG

LICENSE # C-4550

J CLG

15

13

@ 93" AFF @ 93" AFF @ 93" AFF

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

31

12

@ 93" AFF

CASE ENGINEERING, INC. DC

TC1

22

31

@ 15" AFF

W

KP

M D D D

40

TC2

5

MEP ENGINEER

31 J

38

36

40

2' - 6"

10

CLG ABV.

34

19

39 S

16

J D

S

@ 14'-0" AFF

25

W

10

37

S1 28

DC

AS

LEASELINE TO LEASELINE

27' - 4"

1

3

SD

26

10

CLG

35

J

J

CLG

CLG

31

SD 31

J CLG

35

GB

31

24

17 J ST

33

@ 14'-0" AFF

MD TS CLG

@ 14'-0" AFF

S1

CLG

S1 28

CLG

31

D D D

@ 24" AFF

CLG CLGCLG

11

J

9

CLG

9

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

10

CLG

10

25

OSBORN

28

OS

9

TM

23

30 7

STRUCTURAL ENGINEER

20

CLG

8

1

CLG

31

GFI

25

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

EQ

10

ST

43 2

EQ

20' - 10"

41

33

SD

ST

35

9

1

10

25

NORTH

1

POWER & SIGNAL PLAN SCALE: 1/4" = 1'-0"

POWER & SIGNAL PLAN SYMBOL / HATCH LEGEND SYMBOL / HATCH

POWER & SIGNAL GENERAL NOTES:

DESCRIPTION

SYMBOL

EXISTING PARTITION TO REMAIN GFI

NEW PARTITION ROOM NAME 01 SYMBOL

ROOM TAG

S CLG

DESCRIPTION FIRE ALARM SPEAKER/STROBE CEILING SUSPENDED PROVIDE STEM KIT; REF. MEP FOR REQ'D CANDELA RATINGS

NOTE REF. MEP AND APPROVED FIRE ALARM DWGS MOUNT AT VISIBLE HEIGHT

FINISH

QTY

WHITE

1

S

FIRE ALARM SPEAKER/STROBE WALL MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS

REF. MEP AND APPROVED FIRE ALARM DWGS MOUNT AT 96"AFF (MAX)

ST CLG

FIRE ALARM STROBE CEILING MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS

REF. MEP AND APPROVED FIRE ALARM DWGS

SD

SMOKE DETECTOR

REF. MEP DWGS

WHITE

SECURITY CAMERA, SURFACE MOUNTED

COORD. W/ SECURITY VENDOR

MATCH ADJ.

WHITE

WHITE

2 EXG

5

CLG

J CLG

OS

OCCUPANCY SENSOR, WIRELESS CEILING MOUNTED

REF. MEP DWGS

WHITE

1

MD

MOTION DETECTOR WIRELESS

COORD. W/ SECURITY VENDOR

WHITE

1

OS

GB

GLASS BREAK WIRELESS

COORD. W/ SECURITY VENDOR

WHITE

1

M

DC

DOOR CONTACT WIRELESS

COORD. W/ SECURITY VENDOR

KP

CP

WP

SECURITY ALARM KEYPAD SECURITY ALARM CONTROL PANEL WIRELESS ACCESS POINT

COORD. W/ SECURITY VENDOR, MOUNT AT 48" MAX COORD. W/ SECURITY VENDOR COORD. W/ VENDOR

MATCH 2 @ ADJ. ENTRY 1 @ BOH WHITE

1 1

WHITE

1

AUDIO / VISUAL CONTROL PANEL

COORD. W/ A/V VENDOR

WHITE

1

V

VOLUME CONTROLS

COORD. W/ A/V VENDOR MOUNT AT 48" MAX

WHITE

1

WALL MOUNTED SPEAKER

COORD. W/ A/V VENDOR REF. ELEVATIONS FOR MOUNTING HEIGHT

BLACK

COORD. W/ A/V VENDOR

WHITE

S2 CLG T TS TM

FLUSH CEILING SPEAKER

D CLG

CLG TC2

AV

S1

D

TC1

WHITE

NOTE

FINISH

QTY

WALL MOUNTED 20A GROUNDED DUPLEX RECEPTACLE

REF. MEP DWGS MOUNT AT 18" U.N.O.

WHITE

5

WALL MOUNTED 20A GROUNDED DUPLEX RECEPTACLE W/ GROUND FAULT INTERRUPTER

REF. MEP DWGS MOUNT AT 18" U.N.O.

WHITE

2

WALL MOUNTED 20A GROUNDED DEDICATED DUPLEX RECEPTACLE

REF. MEP DWGS MOUNT AT 18" U.N.O.

DEDICATED 4-GANG FLUSH FLOOR BOX: HUBBLE CFB4G30RCR W/ 8"Ø BLACK FLUSH COVER PLATE CFBS1R8CVRBLK; PROVIDE (3) GROUNDED 20A DUPLEX RECEPTACLES AND (1) TELE/DATA OUTLET

3

5

DESCRIPTION

CLG

REF. MEP DWGS INSTALL COVER FLUSH WITH FINISH FLOOR

WHITE

6

1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED ON THIS PLAN AND ELEVATIONS. COORDINATED W/ THE FIXTURE PLAN ANY DISCREPANCIES REGARDING THE LOCATION(S) SHOWN HERE AND THE FIELD VERIFIED OR EXISTING CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT PRIOR TO COMMENCING THE WORK AFFECTED. 2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE ELECTRICAL CODE, NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE COMPANY, AND ALL AUTHORITIES HAVING JURISDICTION. 3. U.N.O. , ALL COVERPLATES AND DEVICES ( ELECTRICAL, SWITCHES, RECEPTACLES, COVER PLATES), SHALL HAVE FINISH COLOR TO MATCH ADJACENT FINISH COLOR.

BLACK

1

TRENCHING REQUIRED

4. SHALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH (2) PULL STRINGS BACK TO THE TELEPHONE EQUIPMENT. 5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALL CHASES IN THE FLOOR, WALLS, AND CEILING SURFACES AND MATERIALS AS REQUIRED.

POWER & SIGNAL PLAN KEY NOTES: 1

LEASE LINE

27

VOLUME CONTROL; FINISH WHITE MOUNTED @ 48" AFF MAX. ONTO TELE/DATA BOARD; REF. ELEVATIONS FOR MOUNTING LOCATION; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK) RECESSED CEILING MOUNTED SPEAKER; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH WHITE

2

EXISTING ELECTRICAL PANEL TO REMAIN; G.C. TO RE-CIRCUIT AS REQUIRED; COORD. W/ MEP DWGS

3

MULTI-CHANNEL 24/7 PROGRAMMABLE TIME CLOCK; COORD. W/ MEP DWGS.

4

SWITCH BANK; FINISH FOR ALL SWITCHES TO BE WHITE; ALL SWITCHES MTD. @ 48" AFF MAX, TYP.; COORD. W/ MEP DWGS

28

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX, MOUNTED; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; REF. ELEVATIONS FOR MOUNTING LOCATIONS

5

MASTER OVERRIDE SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.

6

OCCUPANCY SENSOR COMBINATION SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.

29

RECESSED CEILING MOUNTED SPEAKER; G.C. TO PROVIDE CONDUIT& PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH WHITE.

7

CEILING MOUNTED OCCUPANCY SENSOR; FINISH WHITE

30

ABOVE CEILING DRIVER FOR LED TAPE LIGHTING; COORD. W/ MEP DWGS

8

WALL MOUNTED G.F.I. DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 46" AFF U.N.O.

31

SUSPENDED J-BOX FOR TRACK LIGHTING, LED STRIP LIGHTING AND PENDANTS; COORD. W/ MEP DWGS

9

WALL MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O.

32

CEILING MOUNTED FIRE ALARM SPEAKER/ STROBE; FINISH WHITE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS

10

WALL MOUNTED DEDICATED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O. 33

CEILING MOUNTED FIRE ALARM STROBE; FINISH WHITE; COORD. W/ MEP DWGS &APPROVED FIRE ALARM DWGS

20A GROUNDED DUPLEX CEILING OUTLET

REF. MEP DWGS

WHITE

1

6. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED SHALL BE PATCHED FLUSH WITH ADJACENT WALL SURFACES.

WALL MOUNTED DATA RECEPTACLE

REF. MEP DWGS

WHITE

2

7. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL NOT EXCEED 6".

11

CEILING MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" MAX. FROM GLAZING TYP.

WALL MOUNTED TELE/DATA RECEPTACLE

REF. MEP DWGS

WHITE

1

8. PROVIDE A MINIMUM OF 10% SPACE CIRCUITS IN EXISTING ELECTRICAL PANEL(S) PROVIDE BREAKER LOCKOUTS FOR VAV UNITS AND SEPARATE CIRCUIT OUTLINES AT TELEPHONE EQUIPMENT.

12

MOUNT (2) QUAD RECEPTACLES AND (1) TELE/DATA OUTLET @ 93" AFF ABOVE TELE/DATA BOARD, AND (1) QUAD RECEPTACLE @ 15" MIN. AFF BELOW TELE/DATA BOARD. REF. ELEVATIONS

34

EXISTING FIRE-ALARM SPEAKER-STROBE; G.C. TO CONFIRM THAT FINISH IS WHITE AND IF RED REPLACE WITH EQUIVALENT WHITE DEVICE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS

CEILING MOUNTED J-BOX

REF. MEP DWGS

MATCH ADJ.

11 X

13

PROVIDE (1) LOW VOLTAGE STUB UP @ 15" MIN. AFF BELOW TELE/DATA BOARD AND (1) LOW VOLTAGE STUB UP @ 93" AFF ABOVE DESK. REF. ELEVATIONS

35

CEILING / DECK MOUNTED SMOKE DETECTOR; FINISH WHITE

WHIP CONNECTION

REF. MEP DWGS

MATCH ADJ.

9. ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT CONCEALED WHERE POSSIBLE.

4

36

14

ABOVE CEILING DRIVER FOR STOREFRONT SIGNAGE; COORD. W/ MEP DWGS & SIGNAGE VENDOR; G.C. TO COORD. AND SUPERVISE INSTALL. SIGNAGE FILED UNDER SEPARATE PERMIT.

SWITCH

REF. MEP DWGS

WHITE

2

RUN ALL AV/DATA AND LOW VOLTAGE VENDORS TO B.O.H.; G.C. TO PROVIDE CONDUIT AND PULL STRING FOR ALL. DEDICATED 4-GANG FLUSH FLOOR BOX UNDER BAR (F.16): : HUBBLE CFB4G30RCR W/ 8"Ø BLACK FLUSH COVER PLATE CFBS1R8CVRBLK; G.C. TO TRENCH SLAB AS REQ'D, REF. A-104 FINISH PLAN

37

15

ABOVE CEILING J-BOX FOR STOREFRONT SIGNAGE; COORD. W/ MEP DWGS & SIGNAGE VENDOR; G.C. TO COORD. AND SUPERVISE INSTALL. SIGNAGE FILED UNDER SEPARATE PERMIT. CEILING MOUNTED WIRELESS ACCESS POINT; G.C. TO PROVIDE BACK-BOX CONDUIT AND PULLING

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE MIRROR @ 7'-10" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH

38

16

39

EXISTING FIRE-ALARM SPEAKER-STROBE TO REMAIN; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS

17

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; CENTER ON FITTING ROOM WALL @ 7'-2" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH

40

EXISTING FIRE-ALARM PULL STATION TO REMAIN

41

G.C. TO PROVIDE NEW DISCONNECT SWITCH; COORD. W/ MEP DWGS.

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE RESTROOM MIRROR @ 6'-8" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN POLISHED CHROME; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH

42

G.C. TO SUSPEND EXISTING TRANSFORMER ABOVE; COORD. W/ ELECTRICAL AND STRUCTURAL DWGS

43

G.C. TO RELOCATE EXISTING DISCONNECT SWITCH NEXT TO ELECTRICAL PANEL; COORD. W/ MEP DWGS

44

WALL MOUNTED G.F.I. DUPLEX RECEPTACLE AT RESTROOM; FINISH WHITE; MTD @ 46" AFF U.N.O.

OCCUPANCY SENSOR/SWITCH

REF. MEP DWGS

WHITE

2

MASTER OVERRIDE SWITCH

REF. MEP DWGS

WHITE

1

DIMMER SWITCH

REF. MEP DWGS

WHITE

5

ABOVE CEILING DRIVER FOR STOREFRONT SIGNAGE/LED TAPE

COORD. W/ SIGNAGE VENDER

N/A

10. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM LOCATION AND REQUIREMENTS.

4

TRAFFIC COUNTER PRIMARY UNIT

COORD. W/ RETAILNEXT

WHITE

1

TRAFFIC COUNTER SECONDARY UNIT

COORD. W/ RETAILNEXT

WHITE

1

18

19

PROGRAMMABLE THERMOSTAT, MOUNTED AT 48"AFF MAX; FINISH WHITE; COORD. W/ MEP DWGS.

20

FLUSH WHITE BUTTON TYPE TEMPERATURE SENSOR MOUNTED AT 48"AFF MAX; COORD. W/ MEP DWGS.

21

SHOPPER TRACK TRAFFIC COUNTER; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE

22

SHOPPER TRACK TRAFFIC COUNTER; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE

23

WIRELESS MOTION DETECTOR; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)

24

WIRELESS GLASS BREAK; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)

25

WALL MOUNTED CAMERA; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ SECURITY VENDOR (ADT); G.C. TO PAINT HOUSING TO MATCH ADJ. SURFACE; REF. ELEVATIONS FOR MOUNTING LOCATIONS

26

SECURITY KEYPAD; FINISH WHITE; MTD. @ 48" AFF MAX; G.C. TO COORD. INSTALL W/ SECURITY VENDOR (ADT)

3 2

THERMOSTAT

REF. MEP DWGS MOUNT AT 48" MAX

WHITE

TEMPERATURE SENSOR FLUSH BUTTON TYPE

REF. MEP DWGS MOUNT AT 48" MAX

WHITE

1

MULTICHANNEL TIME CLOCK 24/7 PROGRAMMABLE

REF. MEP DWGS

WHITE

1

1

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

42

RETAIL TENANT

33

LEASE LINE TO LEASE LINE

25

A

STAMP

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

POWER & SIGNAL PLAN

A-103


ARCHITECT

61' - 10"

PW-01

C-02

7 10

7

TYP.

1

2

2

2

2' - 6"

MEP ENGINEER

3' - 0"

CPT-02

14

9' - 6"

26' - 7 5/8"

LEASELINE TO LEASELINE

27' - 4" BOH 08 WALL PT-01A/ PT-02 12 BASE B-02 FLOOR C-04

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

2

14 TYP.

13

TYP.

17

2

OWNER'S REPRESENTATIVE

C-04 8

2' - 5 1/4"

TYP. 10' - 0" SLAB LEAVE-OUT

VIF

VIF

TYP.

5

6 C-02

16

A

C-02

7

12

CASE ENGINEERING, INC.

4

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

TYP.

7 13

2' - 2 3/8" 2

8' - 0"

EQ.

TYP.

2' - 2 3/8" EQ.

2 3

6' - 0"

2 C-02

CPT-01

LICENSE # C-4550

ENTRY 01 WALL PT-01A BASE B-01/PT-01B FLOOR C-02 / CPT-02B

STRUCTURAL ENGINEER

2

2

DISPLAY WINDOW 02 WALL PT-01A BASE N/A FLOOR C-02

LEASE LINE TO LEASE LINE

3

CASUAL/ TAILORED SHOP 03 WALL PT-01A/PT-02 BASE B-01/PT-01B FLOOR C-02

LOUNGE 04 WALL PT-01A BASE B-01/PT-01B FLOOR C-02

2

2

C-02

15

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

1

3 3

A

20' - 10"

10

B

2' - 3 1/4"

11

LEASE LINE TO LEASE LINE

5' - 0"

C

3" MIN.

VESTIBULE 06 WALL PT-01A BASE B-01/PT-01B FLOOR C-02

ADA RESTROOM 07 WALL PT-01D BASE B-01/PT-01E FLOOR C-02

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

1

TYP.

2

2

1' - 6"

8 3/8"

7 3

9

2

3

1

ADA FITTING ROOM 05 WALL PT-01A BASE B-01/PT-01B FLOOR C-02

1

NORTH

FLOOR & WALL FINISH PLAN SCALE: 1/4" = 1'-0"

CONSTRUCTION PLAN SYMBOL / HATCH

FINISH SCHEDULE

SYMBOL / HATCH

FINISH CODE B-01 B-02 C-02

DESCRIPTION

EXISTING PARTITION TO REMAIN

NEW PARTITION

CONCRETE FLOOR

ROOM NAME 01 WALL WALL FINISH BASE BASE FINISH FLOOR FLOOR FINISH

FINISH ROOM TAG

C-04

FLOOR AND WALL FINISH PLAN KEY NOTES:

DESCRIPTION PAINTED WOOD WALL BASE RUBBER WALL BASE EXISTING CONCRETE WITH CUSTOM FINISH

LOCATION SALES BOH SALES/ VESTIBULE/ RESTROOM

MANUFACTURER G.C. JOHNSONITE UNCONVENTIONAL FLOORING

EXISTING CONCRETE WITH CUSTOM FINISH

BOH

UNCONVENTIONAL FLOORING

LOUNGE ENTRY FITTING ROOMS MIRRORS FIXTURES FIXTURES

TBD MATS INC. MAHARAM G.C F.C. G.C. SIGN VENDOR

CPT-01 CPT-02 FB-01 GL-01 MT-01 MT-02 MT-04

REMOVABLE AREA RUG WALK-OFF MAT FABRIC - CURTAIN MIRROR METAL-MATTE BLACK POWDER-COATED METAL - BLACK POWDER-COATED METAL - WHITE

PT-01A PT-01B PT-01C PT-01D

INTERIOR PAINT INTERIOR PAINT INTERIOR PAINT INTERIOR PAINT

WALL DOOR/TRIMS CEILING RESTROOM WALL

BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE

PT-01E

INTERIOR PAINT

RESTROOM DOOR/ TRIM

BENJAMIN MOORE

PT-02

INTERIOR PAINT

BENJAMIN MOORE

PW-01 WD-01 WD-02 WD-03

WATERPROOF POLYWALL WHITE OAK HICKORY WOOD WALNUT WOOD

CEILING @ SALES AREA ABOVE DECORATIVE SLATS MOP SINK FIXTURES FIXTURES FIXTURES MILLWORK

FIXTURES

FINISHES PAINT GRADE POPLAR; REF. PLAN FOR PAINT FINISH TRADITIONAL WALL BASE; MODEL# JODC2824X; FINISH 282 VAPORIZE EXISTING CONCRETE FLOOR TO REMAIN G.C. TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR: CHARCOAL; FINISH: SEMI-GLOSS EXISTING CONCRETE FLOOR TO REMAIN G.C. TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM POLISH AND SEAL; FINISH: CLEAR TBD COCOA MAT - CHARCOAL GRAY CANVAS BY KVADRAT 466185 CLEAR REFLECTIVE MIRROR, TEMPERED BLACKENED METAL TO MATCH CHEMETAL 908 MATTE BLACK POWDER COAT TO MATCH CHEMETAL 908 POWDER COAT TO MATCH PT-01 BENJAMIN MOORE SIMPLY WHITE OC-117 SIMPLY WHITE OC-117; FINISH: EGGSHELL SIMPLY WHITE OC-117; FINISH: SEMI-GLOSS SIMPLY WHITE OC-117; FINSIH: FLAT COROTECH PRE-CATALYZED WATERBRONE EPOXY - V342; COLOR: SIMPLY WHITE OC-117; FINISH: EGGSHELL; LOW VOC COROTECH ACRYLIC DTM ENAMEL - V331; COLOR: SIMPLY WHITE OC-117; FINISH: SEMI-GLOSS; LOW VOC WROUGHT IRON 2124-10; FINISH: FLAT

DIMENSIONS 3/4"D x 4"H 4"H --

-96"W x 72"L 36'W x 72"L REF. PLANS REF. ELEV ---

REMARKS/NOTES REFER TO A-600 FOR DETAILS AND TRIM PROFILES REFER TO A-600 FOR DETAILS GRIND, STAIN, SEAL AND POLISH W/ 16 GRIT DIAMOND TO 1500 GRIT; G.C. TO TEST IN B.O.H. AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT

GRIND 80 GRIT DIAMOND FOLLOWED BY GRIND W/ 100 GRIT TRANSITIONALS; APPLY (2) COATS OF TENNANT ECO-ITS; FINISH: SATIN CLEAR NOT INSET; COORDINATE WITH FLOOR FINISH PLAN; BY OWNER (RETAIL TENANT) INSET; COORDINATE WITH FLOOR FINISH PLAN FURNISHED BY OWNER (RETAIL TENANT); G.C. TO COORD. INSTALL W/ BRAD JOBE; REF. A-500 FOR DETAILS G.C. TO PROVIDE FRAMES FURNISHED BY F.C.; REF. A-101; G.C TO VERIFY DIMS IN FIELD AND SECURE TO FRAMES W/ MASTIC G.C. TO PROVIDE SAMPLE FOR APPROVAL SIGN VENDOR TO PROVIDE SAMPLE FOR APPROVAL

1

LEASE LINE

2

G.C. TO SUPPLY AND INSTALL NEW PAINTED WOOD WALL BASE, B-01; REF. A-600 FOR DETAILS

3

G.C. TO SUPPLY AND INSTALL NEW RUBBER WALL BASE, B-02; REF. A-600 FOR DETAILS

4

EXISTING ADA COMPLIANT THRESHOLD AT STOREFRONT ENTRY TO REMAIN; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)

5

G.C. TO TRENCH SLAB TO RUN POWER UNDERNEATH TO FLUSH MOUNTED FLOOR BOX; REF. A-103 POWER & SIGNAL PLAN

6

G.C. TO PROVIDE NEW REMOVABLE WALK-OFF MAT

7

EXISTING CONCRETE FLOOR TO REMAIN, G.C TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR BY RETAIL TENANT REQUIRED VENDOR; CHARCOAL; FINISH; SEMIGLOSS; REF. A-600

8

EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO PREP FLOOR PER VENDOR RECCOMENDATION FOR NEW GRIND AND SEAL BY RETAIL TENANT VENDOR; FINISH: CLEAR

9

NEW REMOVABLE AREA RUG BY OWNER (RETAIL TENANT); NO TRIP HAZARD AT PERIMETER OF AREA RUG. CARPET TO COMPLY WITH ADA LEVEL CHANGE REQUIREMENTS (ADA 2010 SECTION 303) AND SHALL NOT EXCEED 1/4" THK. OR 1/2" THK IF EDGE IS BEVELED AT A SLOPE NOT STEEPER THAN 1:2.

STAMP

-----

G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL

--

LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL

--

G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL; PAINT LINE AT BOH: 12'-0" AFF. G.C. TO PAINT ALL WALLS ABOVE THIS LINE PT-02.

10

G.C. TO USE MOISTURE-RESISTANT TYPE "X" GWB AT THE WALLS IN WET AREAS, INCLUDING THE RESTROOM, TYP.

G.C. TO CUT DOWN AS REQUIRED, REF. PLANS & ELEVS FOR SIZE FINISH TO MATCH CONTROL SAMPLE FINISH TO MATCH CONTROL SAMPLE FINISH TO MATCH CONTROL SAMPLE

11

NEW PLASTEX PLOYWALL WATERPROOF PANEL UP TO 48" AFF AT THE MOP-SINK SURROUND, REF. ELEVATIONS.

12

G.C. TO ESTABLISH A PAINT LINE @ 12'-0" AFF AT B.O.H. PAINT WALLS PT-01A BELOW 12'-0" AFF AND PT-02 ABOVE 12'-0" AFF

13

G.C. TO ESTABLISH A PAINT LINE @ 11'-9" AFF AT SALES AREA WALLS. PAINT WALLS PT-01A BELOW 11'-9" AND PT-02" ABOVE 11'-9"

14

NEW DOOR AND FRAME; PAINT PT-01B U.N.O., REF. ELEVATIONS

PROJECT NO.: 218259

3. ALL CONCRETE FINISHES TO FOLLOW DESCRIPTION PROVIDED IN FINISH SCHEDULE; SAMPLE TO BE PROVIDED IN FINISH SCHEDULE; G.C. TO TEST FINISH IN BOH AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT.

15

LANDLORD G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT ADD-ALT IF NOT PROVIDED BY LANDLORD, G.C. TO PROVIDE IN-FILL; REF. LANDLORD DWGS. FOR REQUIRED SLAB INFILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS

DATE: 02/27/2019

4. INSTALLATION OF FINISHES AND FIXTURES TO BE COORDINATED BETWEEN G.C., F.C., AND ALL VENDORS, TYP.

16

EXISTING LANDLORD SIDEWALK TO REMAIN

17

EXISTING DOOR AND FRAME; G.C. TO PAINT PT-01E U.N.O., REF. ELEVATIONS

X-01

X

FINISH TAG

THRESHOLD TAG WALL BASE LOCATION

FINISH PLAN GENERAL NOTES: 1. ALL FINISHING AND PAINTING REQUIREMENTS BE AS PER FINISH SCHEDULE, ELEVATIONS AND SPECIFICATIONS. 2. ALL INTERIOR GWB PAINT TO BE SPRAY APPLIED AND BACKROLL FINISHED. SAMPLE TO BE PROVIDED TO ARCHITECT FOR APPROVAL. G.C. AND F.C. TO COORDINATE AND MATCH PAINTED FINISHES.

5. G.C. TO SUBMIT SAMPLES OF ALL FINISHES FOR FINAL APPROVAL PRIOR TO ORDERING OF MATERIALS OR INSTALLATION.

PLAS-TEX F.C. F.C. F.C.

POLYWALL MODEL# PTC0043M; FINISH WHITE NATURAL OAK WOOD, PLAIN SAWN; FINISH: CLEAR MATTE NATURAL HICKORY WOOD; FINISH: CLEAR MATTE NATURAL WALNUT WOOD; FINISH: CLEAR MATTE

48"H ----

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

RETAIL TENANT

10

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

6. ALL MATERIALS AND FINISHES MUST BE FIRE-RATED AND HAVE FLAME RESISTANCE COMPLYING WITH LOCAL & STATE CODES. 7. ALL SURFACES AT TRANSITIONS BETWEEN DIFFERENT OR EXISTING NEW MATERIALS TO BE FLUSH AND/OR A.D.A. COMPLIANT 8. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.

FLOOR & WALL FINISH PLAN

A-104


ARCHITECT

PAINT-GRADE INTERNALLY INSULATED DUCT; FINISH TO MATCH ADJ. PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP. SUSPENDED TRACK LIGHTING FINISH BLACK; TYP.

PENDANT LIGHT FIXTURES; TYP.

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF

G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02

20' - 9" A.F.F. 2ND FLOOR 19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

11' - 0" A.F.F. STOREFRONT DISPLAY 10' - 11" A.F.F. T.O. STOREFRONT V.I.F.

NEW WOOD DECORATIVE BEAMS; COORD. W/ RCP; FINISH TO MATCH WD-02

CASUAL/ TAILORED SHOP 03

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER

CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550 STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

8' - 2" A.F.F. B.O. ENTRY SOFFIT VIF

DISPLAY WINDOW 02

EXISTING STOREFRONT TO REMAIN

RETAIL TENANT

PT-01A

OWNER'S REPRESENTATIVE

2 A-502

96" MAX

11' - 0"

8' - 8"

OPEN TO VESTIBULE BEYOND

7' - 10"

FINISHED TRANSITION

GL-02

11' - 5" A.F.F. LIGHT COVE

SPEAKER MOUNTING, TYP.

BOH 08

7' - 0"

11' - 3"

PT-01A

16' - 0"

15' - 0" MIN.

LOUNGE 04

WD-02

B.O. PENDANT, TYP.

PT-01A

B.O. DUCT, TYP.

PT-01A

13' - 3" A.F.F. B.O. TRACK 11' - 9" A.F.F. B.O. BEAMS

PT-02

14' - 0"

WALL MOUNTED CAMERA

5 A-501

SUSPENDED J-BOX, TYP.

PT-02

16' - 0" A.F.F. B.O. SUSPENED J-BOX

CUT CORD LENGTHS IN FIELD AS REQ'D

5' - 11 3/4" VIF

NEW WOOD DECORATIVE BEAMS; COORD W/ RCP; FINISH WD-02

TELE/ DATA BOARD W/ FOLDING DESK

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

1' - 6" A.F.F. KNEE WALL 0' - 0" A.F.F. FINISHED FLOOR

B-02

BOH SHELVING

2

B-01

FREE-STANDING FITTING ROOMS BY F.C.

NEW FIXTURE BY F.C.; COORD. IN-WALL BLOCKING AND FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYP. DIMENSIONS SHOWN

SECTION B SCALE: 3/8" = 1'-0"

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF

PENDANT LIGHT FIXTURE; TYP.

PAINT-GRADE INTERNALLY INSULATED DUCT; FINISH TO MATCH ADJ. PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP.

SUSPENDED TRACK LIGHTING FINISH BLACK; TYP.

CHANDELIER TBD (RETAIL TENANT); G.C. TO PROVIDE LAMPS VERIFY TYPE W/ TENANT PRIOR TO PURCHASE 20' - 9" A.F.F. 2ND FLOOR

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

WALL MOUNTED CAMERA G.C. TO PAINT HOUSING TO MATCH ADJ. FINISH PT-01A

G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; REF. ELECTRICAL AND STRUCTURAL DWGS

19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

NEW WOOD DECORATIVE BEAMS; COORD W/ RCP; FINISH TO MATCH WD-02

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 10'-3" AFF

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 11'-3" AFF

PT-02 PT-02

PT-01A

BOH 08

PT-01A

11' - 0" A.F.F. LOUNGE CEILING

B.O. DUCT, TYP.

PROJECT NO.: 218259

11' - 3"

GL-02

B.O. CHANDELIER

8' - 8"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

10' - 3"

B.O. PENDANT, TYP.

8' - 8"

15' - 0" MIN.

SPEAKER MOUNTING, TYP.

GL-02

14' - 0"

CASUAL/ TAILORED SHOP 03

12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS

LOUNGE 04

PT-01A

10' - 3"

NEW RETAIL TENANT LOGO: 15"H COLORED LED ILLUMINATED NEON LOOK LETTERS. EACH LETTER TO HAVE INDIVIDUAL WHITE METAL BACKS. EACH LETTER TO BE ENCLOSED IN INDIVIDUAL, NON REFLECTIVE CLEAR ACRYLIC BOXES. G.C. TO SUSPEND EACH SIGN BOX FROM INTERIOR CEILING AT TWO POINTS WITH LETTERS CENTERED IN THE WINDOW. G.C. TO PROVIDE CONCEALED J-BOX AND ACCESS AT INTERIOR. COORDINATE INSTALL AND LOCATION WITH SIGNAGE VENDOR. SIGNAGE TO BE CONTROLLED BY 24/7 PROGRAMMABLE TIME CLOCK. SIGNAGE FILED UNDER SEPARATE PERMIT

DATE: 02/27/2019 DRAWN BY: NK, VR CHECKED BY: JSP AREA: 1,400 SF

#

1

SECTION A SCALE: 3/8" = 1'-0"

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 10'-3" AFF

HOLD

10"

TYP

1' - 6"

HOLD

10"

PT-01A

NEW FIXTURE BY F.C.; COORD. IN-WALL BLOCKING AND FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYP. DIMENSIONS SHOWN

STAMP

FREE-STANDING FITTING ROOMS BY F.C.

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

0' - 0" A.F.F. FINISHED FLOOR

BOH SHELVING

BUILDING SECTIONS

A-300


19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

ARCHITECT

G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02 WALL MOUNTED SPEAKER WITH CONCEALED INWALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKER ARE INSTALL TOWARD SALES FLOOR; MOUNT @ 14'-0" B.O.J-BOX

PT-02

5' - 11 3/4" PT-01A

5"

DECORATIVE BEAMS, FINISH TO MATCH WD-02 13' - 3" A.F.F. B.O. TRACK 11' - 9" A.F.F. B.O. BEAMS & PAINT LINE 11' - 0" A.F.F. SALES CEILING 20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" AFF

STRUCTURAL ENGINEER

ENGINEERING

5' - 8"

3" F.01

8' - 8"

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W / FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN

WD-01

1' - 0"

F.03

B-01 PT-01B

1' - 0"

TYP.

1' - 6"

TYP.

1' - 6"

1' - 0"

HOLD

10"

2' - 0"

NEW DEDICATED DUPLEX RECEPTACLE

FLUSH WHITE BUTTON TYPE TEMPERATURE SENSOR

2

LICENSE # C-4550

OSBORN

5' - 0"

1' - 0" 1' - 0" 48"AFF MAX 2' - 0"

1 A-502

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

MT-01

1' - 0"

NEW DUPLEX RECEPTACLE BEHIND

PT-01A

10' - 3"

1' - 0"

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION.

F.01

1' - 0"

1' - 0"

MQ

CASE ENGINEERING, INC.

5' - 0"

5' - 8"

MEP ENGINEER

TM

B.O. PENDANT, TYP

3"

16' - 0"

2' - 4"

14' - 0"

A.03

1/2"

SPEAKER MOUNTING, TYP.

PT-01A

SUSPENDED J-BOX, TYP.

2 A-502

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

0' - 0" A.F.F. FINISHED FLOOR

NEW DUPLEX RECEPTACLE

SALES - SOUTH SCALE: 1/2" = 1'-0"

19' - 9" A.F.F. B.O. EXISTING DECK V.I.F. G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKER ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF

PT-02

PAINT- GRADE INTERNALLY INSULATED SPIRAL STEEL DUCT BY G.C.; FINISH: PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP. NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF.

16' - 0" A.F.F. B.O. SUSPENED J-BOX

CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D

5' - 11 3/4"

PT-02

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR, PT-01A MOUNT @ 11'-0" AFF

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

NEW SURFACE MOUNTED TRACK LIGHTING AT LIGHT COVE. FINISH: WHITE.

NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF.

OWNER'S REPRESENTATIVE

RETAIL TENANT

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 10'-3" AFF

CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D

16' - 0" A.F.F. B.O. SUSPENED J-BOX

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

DECORATIVE BEAMS, FINISH TO MATCH WD-02

STAMP

PT-02 13' - 3" A.F.F. B.O. TRACK

11' - 9" A.F.F. B.O. BEAMS & PAINT LINE 11' - 0" A.F.F. ENTRY CEILING

WD-02

NEWDUPLEX RECEPTACLE

1

SALES - NORTH SCALE: 1/2" = 1'-0"

7"

96" MAX

F.01

EXISTING FIRE-ALARM SPEAKER STROBE TO REMAIN; G.C. TO CONFIRM EXISTING IS WHITE; ADD-ALT: IF NOT WHITE REPLACE W/ WHITE EQUIVALENT NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W / FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01 B-01 PT-01B

1' - 0"

TYP.

NEW RETAIL TENANT LOGO: 15"H COLORED LED ILLUMINATED NEON LOOK LETTERS. EACH LETTER TO HAVE INDIVIDUAL WHITE METAL BACKS. EACH LETTER TO BE ENCLOSED IN INDIVIDUAL, NON REFLECTIVE CLEAR ACRYLIC BOXES. G.C. TO SUSPEND EACH SIGN BOX FROM INTERIOR CEILING AT TWO POINTS WITH LETTERS CENTERED IN THE WINDOW. G.C. TO PROVIDE CONCEALED J-BOX AND ACCESS AT INTERIOR. COORDINATE INSTALL AND LOCATION WITH SIGNAGE VENDOR. SIGNAGE TO BE CONTROLLED BY 24/7 PROGRAMMABLE TIME CLOCK. SIGNAGE FILED UNDER SEPARATE PERMIT

5' - 8" 1' - 0"

F.03

B.O. DUCT, TYP.

15' - 0" MIN.

8' - 8" A.F.F. T.O. ENTRY SOFFIT

5' - 0"

B.O. PENDANT

1' - 6"

B-01 PT-01B

1' - 0"

5' - 0"

8' - 8"

11' - 0"

1' - 0"

F.01

PT-01A

SPEAKER MOUNTING, TYP.

MT-01

10' - 10"

14' - 0"

WD-01

7"

CEILING MOUNTED EXIT SIGN CENTERED OVER DOOR.

SUSPENDED J-BOX, TYP.

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W / FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN

16' - 0"

20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" A.F.F.

0' - 0" A.F.F. FINISHED FLOOR

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: Author CHECKED BY: Checker AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

INTERIOR ELEVATIONS CASUAL SHOP & TAILORED SHOP

A-301


ARCHITECT

G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02

19' - 9" A.F.F. B.O. EXISTING DECK V.I.F. PAINT- GRADE INTERNALLY INSULATED SPIRAL STEEL DUCT BY G.C. FINISH: PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP.

NEW RETURN AIR GRILLE; MOUNT AS HIGH AS POSSIBLE; B.O. GRILLE AT 14' - 6" AFF MIN. PAINT TO MATCH ADJ FINISH. PT-02

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF. DECORATIVE BEAMS, FINISH TO MATCH WD-02 16' - 0" A.F.F. B.O. SUSPENED J-BOX

16' - 0"

& PAINT LINE

8"

11' - 0" A.F.F. SALES CEILING 20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" AFF

MEP ENGINEER

CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550 STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

PT-01A

F.01

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN. WD-01 MT-01

F.15 BS

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

2

SALES - WEST SCALE: 1/2" = 1'-0" 19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

PAINT-GRADE INTERNALLY INSULATED SPIRAL STEEL DUCT BY G.C. RETAIL TENANT G.C. TO PAINT PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP.

NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF.

G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

F.16

RETAIL TENANT

8' - 8"

OPEN TO LOUNGE BEYOND

BS

11' - 9" A.F.F. B.O. BEAMS

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

11' - 0"

TYP.

B.O. RETURAN AIR GRILLE

14' - 6" MIN.

SPEAKER MOUNTING, TYP.

F.01

14' - 0"

PT-01A

15' - 0" B.O. DUCT MIN.

PT-01A

13' - 3" A.F.F. B.O. TRACK

SUSOENDED J-BOX, TYP.

WD-02

CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D

5' - 11 3/4"

PT-02

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , MOUNT @ 11'-0" AFF G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A

B.O. PENDANT

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL JBOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKER ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF

OWNER'S REPRESENTATIVE

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL JBOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF

PT-02

5' - 11 3/4"

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL JBOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'- 0" AFF WD-02 PT-01A

CEILING MOUNTED EXIT SIGN CENTERED OVER TRANSITION DOOR. MOUNT @11'-0" A.F.F..

CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D

16' - 0" A.F.F. B.O. SUSPENED J-BOX DECORATIVE BEAMS, FINISH TO MATCH WD-02

13' - 3" A.F.F. B.O. TRACK

11' - 8" A.F.F. WALL WASHER COVE 11' - 0" A.F.F. ENTRY CEILING WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD, MOUNT @ 10'-3" AFF,G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A

SUSPENDED J-BOX, TYP.

1' - 6"

MQ

3' - 4"

1

SALES - EAST SCALE: 1/2" = 1'-0"

WD-01

1' - 6"

4' - 2"

3' - 8"

48"AFF MAX

F.10

10' - 3"

2' - 6"

1' - 0" B.O. PENDANT

8' - 8"

1' - 0"

1' - 0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

8' - 2" A.F.F. B.O. ENTRY SOFFIT VIF

PROJECT NO.: 218259

BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE IN-WALL FRT BLOCKING AS REQ'D

DRAWN BY: Author

A.05

1' - 0"

EXISTING STOREFRONT DOOR TO REMAIN; G.C. TO CONFIRM EXISTING LOCK IS SFIC AND PROVIDE NEW 'BEST' LOCK CORE OR APPROVED EQUAL 7-PIN SMALL FORMAT INTERCHANGEABLE CORE AND 6 SETS OF KEYS; IF EXISTING LOCK IS NOT SFIC; G.C. TO REPLACE LOCK AND CORE PER ABOVE; FINISH: COLOR TO MATCH ADJ

8' - 8" A.F.F. T.O. ENTRY SOFFIT

PT-01A

1' - 6"

16' - 0"

B.O. DUCT, TYP.

15' - 0" MIN

SPEAKER MOUNTING, TYP.

14' - 0"

20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" A.F.F.

EXISTING FIRE ALARM PULL STATION TO REMAIN

STAMP

20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. 24" STEMS REQ; B.O. PENDANT MOUNTED @ 8'-8" A.F.F.

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01

MT-01

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION. F.01 B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

DATE: 02/27/2019 CHECKED BY: Checker AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

INTERIOR ELEVATIONS CASUAL SHOP & TAILORED SHOP

A-302


ARCHITECT

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

OWNER'S REPRESENTATIVE

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER

CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550 STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

7' - 11" 7 A-500

PT-01B WD-01

F.22 A.03

1' - 0"

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02

1' - 0 1/4"

11' - 0" A.F.F. LOUNGE CEILING

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD ,MOUNT @ 10'-3" AFF, G.C. TO PAINT METAL HOUSING TO MATCH ADJ. PT-01A

PT-01A

1"

F.22

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02

6' - 5 1/4"

MIRROR HOLD

1' - 0"

10"

1' - 0"

GL-02

1' - 0"

SO

CT

LOUNGE - WEST

2

SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR

NEW DUPLEX RECEPTACLE STAMP

LOUNGE - SOUTH SCALE: 1/2" = 1'-0"

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT @ 7'-10"AFF FINISH WHIP TO MATCH ADJ SURFACE PT-01A

11' - 0" A.F.F. LOUNGE CEILING

11' - 0" A.F.F. LOUNGE CEILING

6"

8"

2' - 0"

FB-01 FREE STANDING FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS

1' - 6"

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

TYP.

3' - 0" FB-01

B-01 PT-01B

MIRROR

1' - 0"

3"

8' - 8"

04

1' - 11 1/4"

1' - 0"

PT-01A

PT-01A

B.O. CHANDELIER

DOOR TO BOH

OPEN TO ADA FR ROOM BEYOND

6' - 10"

CURTAIN ON RECESSED TRACK AT ADA FITTING ROOM

FINISHED TRANSITION

7' - 0"

GL-02

4

2' - 4"

FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C.; BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01

A.03

NEW CUSTOM DOOR FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE SILENCERS AND MIRROR; G.C. TO COORD. ROUGH OPENING DIMENSIONS WITH APPROVED FINAL SHOP DWGS. WD-01 GL-02

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , MOUNT @ 10'-3" AFF, G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A

PT-01A

NEW 3-WAY MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. INWALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

EQ

6"

6"

PT-01A

MIRROR

MIRROR

GL-02

6' - 6"

1' - 7" 1' - 0" 1' - 7"

1' - 0 7/8"

NEW 3-WAY MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION MT-01 GL-02

NEW DUPLEX RECEPTACLE B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

BS

LOUNGE - EAST

2' - 7 7/8"

TYP.

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

DATE: 02/27/2019

1' - 6"

TYP.

1' - 6"

B-01 PT-01B

OPENING TO VESTIBULE

1

LOUNGE - NORTH SCALE: 1/2" = 1'-0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259

7' - 4 3/8" MIRROR

NEW DUPLEX RECEPTACLE

48 AFF MAX. B-01 PT-01B

7' - 0"

FIRE EXTINGUISHER

F.16

FINISHED TRANSITION

MIRROR

G.C. TO PROVIDE 3/4"THK CONCEALED IN-WALL FRT PLYWOOD BLOCKING FOR FUTURE SIGNAGE LOCATION

EQ

1' - 0"

10' - 3"

1' - 0 7/8"

1' - 10"

PT-01A

OPENING TO SALES BEYOND

F.15

SCALE: 1/2" = 1'-0"

3' - 6"

EQ

REF-1

3

EQ

1' - 0"

A.01

PT-01A

FUTURE ILLUMINATED SIGNAGE LOCATION 4' - 6"

4' - 0"

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT @ 7'-10"AFF; PAINT WHIP TO MATCH ADJ. FINISH PT-01A

RETAIL TENANT

PT-01A

PT-01A

FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE 3/4" FRT PLYWOOD INWALL BLOCKING BY G.C. BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

CHANDELIER TBD (RETAIL TENANT); G.C. TO PROVIDE LAMPS VERIFY TYPE W/ TENANT PRIOR TO PURCHASE

11' - 0" A.F.F. LOUNGE CEILING

DRAWN BY: Author CHECKED BY: Checker AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

INTERIOR ELEVATIONS LOUNGE & FITTING ROOMS

A-303


ARCHITECT

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

OWNER'S REPRESENTATIVE

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER

CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550 STRUCTURAL ENGINEER

TM

OSBORN ENGINEERING

9' - 0" A.F.F. VESTIBULE CEILING

PT-01A

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01

PT-01E

DOOR TO ADA RESTROOM

EQ

EQ

1' - 0"

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01

EQ

NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01

EQ

2' - 6"

8 7/8"

PT-01A 5' - 8"

EQ

7' - 0"

5' - 0"

EX-03

0' - 0" A.F.F. FINISHED FLOOR

NEW DUPLEX RECEPTACLE

OPENING TO LOUNGE

B-01 PT-01B

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

TYP

3' - 8"

1' - 11 1/2"

1' - 6"

B-01 PT-01B

1' - 0"

4' - 2"

BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE INWALL FRT BLOCKING AS REQ'D. MT-01

1' - 0"

3' - 0"

5' - 0"

3' - 6 1/2"

B-01 PT-01B

WALL MOUNTED EXIT SIGN CENTERED OVER TRANSITION DOOR. MOUNT @8'-6" A.F.F.

EQ

8' - 6"

EXISTING ADA COMPLIANT RESTROOM SIGN BY LANDLORD'S G.C.

1' - 0"

PT-01E

PT-01A

1' - 0"

PT-01A

8' - 6"

9' - 0" A.F.F. VESTIBULE CEILING

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

9' - 0" A.F.F. VESTIBULE CEILING

FINISHED TRANSITION

9' - 0" A.F.F. VESTIBULE CEILING

1' - 6"

WALL MOUNTED EXIT SIGN CENTERED OVER TRANSITION DOOR. MOUNT @ 8'-6" A.F.F.

RETAIL TENANT

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

EXISTING RESTROOM DOOR TO REMAIN; G.C. TO PAINT AND REPLACE EXISTING HARDWARE W/ BLACK HARDWARE REF. DOOR SCHEDULE

STAMP

VESTIBULE WEST

8

6

SCALE: 1/2" = 1'-0"

VESTIBULE NORTH

4

SCALE: 1/2" = 1'-0"

VESTIBULE EAST

2

SCALE: 1/2" = 1'-0"

VESTIBULE SOUTH SCALE: 1/2" = 1'-0"

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION.

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

7

SCALE: 1/2" = 1'-0"

5

ADA FITTING NORTH SCALE: 1/2" = 1'-0"

3

ADA FITTING SOUTH SCALE: 1/2" = 1'-0"

1

ADA FITTING WEST SCALE: 1/2" = 1'-0"

HOLD

1' - 9"

DATE: 02/27/2019 DRAWN BY: Author CHECKED BY: Checker

2' - 0"

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

6"

4' - 0"

6"

PROJECT NO.: 218259

AREA: 1,400 SF

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

CURTAIN ON RECESSED TRACK AT ADA FITTING ROOM

ADA FITTING EAST

F.12

4"

HOLD

ADA BENCH BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN WALL FRT PLYWOOD BLOCKING AS REQ'D WD-01

HOLD 3' - 0"

2' - 0"

1' - 5"

4" 1' - 5"

B-01 PT-01B

1' - 2"

F.12

1' - 0"

1' - 0"

1' - 0" 1' - 0"

6"

3 1/2"

A.05

3' - 6"

4' - 0"

5' - 0"

HOLD

ADA BENCH BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN WALL FRT PLYWOOD BLOCKING AS REQ'D WD-01

BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE IN-WALL FRT BLOCKING AS REQ'D MT-01

3" 3" 3" 3" 1' - 0" A.04

1' - 8"

2' - 10" 4' - 0"

HOLD

4' - 0"

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

A.04

PT-01A

3' - 6"

2' - 5"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

HOLD

2' - 10"

1' - 9"

HOLD

1' - 6 1/2"

9' - 0" A.F.F. FITTING ROOM CLG

ADA HANG BAR FURNISHED BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D. MT-01

PT-01A

A.02

2' - 5"

B-01 PT-01B

10"

ADA HANG BAR FURNISHED BY F.C. INSTALLED BY G.C.;G.C. TO PROVIDE INWALL FRT PLYWOOD BLOCKING AS REQ'D. MT-01

HOLD

A.05

BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE INWALL FRT BLOCKING AS REQ'D MT-01

TYP.

HOLD 5' - 0"

4' - 0"

1' - 0"

GL-02

A.02

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02

5' - 0"

ADA HANG BAR FURNISHED BY F.C. INSTALLED BY G.C.;G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D. MT-01

MIRROR

PT-01A

1' - 0"

1' - 11 1/4"

MIRROR

1' - 0" 1' - 0"

7 1/8"

1' - 0"

OPENING TO LOUNGE

2' - 4"

2' - 0"

FINISHED TRANSITION

7' - 0"

1' - 0"

1' - 0"

2 7/8"

5' - 11 1/4"

A-500

PT-01A

1' - 0"

NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02

7

9' - 0" A.F.F. FITTING ROOM CLG

9' - 0" A.F.F. FITTING ROOM CLG

5' - 0"

9' - 0" A.F.F. FITTING ROOM CLG

INTERIOR ELEVATIONS ADA FITTING ROOM/ VESTIBULE & RESTROOM

A-304


19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

NEW SUPPLY AIR GRILLE; COORD. W/ MEP DWGS; MOUNT AS HIGH AS POSSIBLE; B.O. GRILLE AT 14' - 6" AFF MIN. PAINT TO MATCH ADJ FINISH. PT-02

PT-02

PT-02

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 11'-3" AFF

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR, PT-01A MOUNT @ 11'-3" AFF

PT-02

4' SUSPENDED LINEAR LED LIGHTS, TYP. FINISH: WHITE.

6"

6"

12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS

12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS

SHB

SHBH

SHBH

SHBH

BST

SHB

SHB

SHB

3' - 4"

EXISTING ELECTRICAL PANELS TO REMAIN' G.C. TO RE-CIRCUIT AS REQUIRED

PT-01B

G.C. TO RELOCATE EXISTING DISCONNECT SWITCH NEXT TO NEW DISCONNECT SWITCH REF. MEP DWGS.

TDSH

1' - 4"

PL.06

SH16 B16

FIRE RATED EXIT DOOR TO PARKING GARAGE

EXISTING FIRE ALARM PULL STATION TO REMAIN

CB

KB

11' - 3"

EL

B16

SHBH

INFILL AT BACK WALL TO BE EXISTING BY LANDLORD

VOLUME CONTROLS; MOUNT @ 48" AFF MAX.

4

BOH WEST SCALE: 1/2" = 1'-0"

NEW TELE/DATA BOARD 3/4" FRT PLYWOOD, PAINTED TO MATCH ADJACENT FINISH PT-01A

48"AFF MAX

42" AFF MAX

SWITCHBANK

48"AFF MAX

WATER COOLER

48" MAX.

5' - 0"

4' - 6"

SHB

EMPLOYEE LOCKER

UH

02 PT-01B

FDSK

SECURITY KEYPAD MOUNT @ 48" AFF MAX.

NEW TIMECLOCK MOUNT @ 48" AFF MAX.

8" 9' - 10"

BOH SOUTH

2

SCALE: 1/2" = 1'-0"

4' - 0"

TDSH: WALL MOUNTED RECEIVER SHELF G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.

3

PLAYLIST GENERATION - AUDIO RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

4

ADT MONITOR G.C. TO COORD. & SUPERVISE VENDOR INSTALL

5

AUDIO CONTROLLERS - MOUNT AT 48" AFF MAX. G.C. TO COORD. & SUPERVISE VENDOR INSTALL

6

BANDWAVE - PEPWAVE - CELLULAR ROUTER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

7

RETAIL NEXT - ALLIED TELESIS - POE SWITCH (ONLY OCCURS AT MEDIUM TO LARGE STORES) G.C. TO COORD. & SUPERVISE VENDOR INSTALL

8

ISP INTERNET HAND-OFF G.C. TO COORD. & SUPERVISE VENDOR INSTALL

9

RETAIL NEXT - HIK VISION G.C. TO COORD. & SUPERVISE VENDOR INSTALL

10

POWER GEAR SURGE PROTECTOR G.C. TO FURNISH AND INSTALL

11

ADT SWITCH G.C. TO COORD. & SUPERVISE VENDOR INSTALL

12

ADT MAIN BOX G.C. TO COORD. & SUPERVISE VENDOR INSTALL

13

CISCO MERAKI FIREWALL - G.C. TO SUPERVISE VENDOR INSTALL

ADT ALARM SIREN G.C. TO COORD. & SUPERVISE VENDOR INSTALL

16

ADT VIDEO RECORDER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

0' - 0" A.F.F. FINISHED FLOOR

1

TELE/DATA BOARD W/ DESK SCALE: 1" = 1'-0"

5"

5"

1' - 4 1/2"

EQ

EQ

4

3

NEW TELE/DATA BOARD 3/4" FRT PLYWOOD, PAINTED TO MATCH 2 ADJACENT FINISH PT-01A

15

STAMP

1

13

6

16

12

8

7

9 11

KB: KEYBOX - MOUNT AT 48" AFF MAX. G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.

15

5"

3"

SOUND GENERATION - AMP RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

1' - 4 1/2"

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

TYP.

1' - 6"

NEW DUPLEX RECEPTACLE 0' - 0" A.F.F. FINISHED FLOOR

SCALE: 1/2" = 1'-0"

2

14

RETAIL TENANT

1' - 4" 4' - 6"

1' - 0"

B-02

BOH NORTH

FIRE EXTINGUISHER; REF. G-003 FOR MOUNTING DETAIL

B-02

11' - 3"

SHB

14

7' - 9"

EXISTING FIRE ALARM SPEAKER STROBE TO REMAIN

BOH SHELVING, TYP. SH16

SHB

SHBH

6' - 0"

8"

BR

SHBH SHB

SHBH

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 5

DATE: 02/27/2019

10

DRAWN BY: Author CHECKED BY: Checker AREA: 1,400 SF

#

2 1/2"

3' - 7"

2 1/2"

MIN. 1' - 6"

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 11'-3" AFF

PT-01A

1 A-305

B16

B16

1' - 3"

12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS

SH16

B16

MOUNT ALL LOW VOLTAGE EQUIP. ABOVE 36" AFF

EXISTING EXIT SIGN / EM COMBO TO REMAIN

BOH SHELVING, TYP.

SH16

MOUNT KEYBOX, AUDIO CONTROLS, AND KEPAD AT 48" AFF MAX. 3' - 0"

PT-02

SH16 B16

SH16

MIN.

4' SUSPENDED LINEAR LED LIGHTS, TYP. FINISH: WHITE.

PT-02

BST

B16

TELE/DATA BOARD EQUIP. LEGEND 1

G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; REF. ELECTRICAL AND STRUCTURAL DWGS.

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

B16

4' - 6"

5' - 0"

4' - 6"

1' - 0"

19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

OSBORN

0' - 0" A.F.F. FINISHED FLOOR

5

PT-01A

SH16

0' - 0" A.F.F. FINISHED FLOOR

B-02

TM

SH16

SH16 B16

B-02

NEW DUPLEX RECEPTACLE

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

SHB

1' - 6"

TYP.

1' - 6"

3' - 0" TYP.

1' - 6"

THERMOSTAT; MOUNT @ 48" AFF MAX.

CASE ENGINEERING, INC.

SH16

3' - 4"

3' - 4"

SHBH

SCALE: 1/2" = 1'-0"

PT-01A

1' - 4"

B16

BOH EAST

PT-02

UH

SH16

SHB

MEP ENGINEER

BOH SHELVING, TYP.

9' - 10"

1' - 4"

SH16 B16

8"

B16

1' - 0"

3"

4' - 6"

6

REFRIGERATOR NEW DUPLEX RECEPTACLE BEHIND

B16

SHB

REF-2

B-02

B16

4' - 0"

B16

B16

7' - 0"

SHB

SH16

B16

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

STRUCTURAL ENGINEER

BST

SH16

9' - 10"

1' - 0" DOOR TO LOUNGE 04

8' - 0"

9' - 10"

SH16

PL.05

1' - 1"

SH16 B16

1' - 4"

PL.04

B16

WD-01

1' - 0"

SH16

3' - 4"

1' - 6" SHB

BR

BOH SHELVING, TYP.

OWNER'S REPRESENTATIVE

LICENSE # C-4550

SH16

SHB

SH16

PT-01A

BR

SH16

BST

3' - 4" PT-01A

BST

B16

B.O. GRILLE, TYP.

BR

8"

SH16

PT-01B

PW-01

BR

11' - 3"

BST

12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS

PT-01A

WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , MOUNT @ 11'-3" AFF, G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A

11' - 3"

BST SH16 B16 SHB

1' - 0"

NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN AFF AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT/BRACING AS REQ'D; COORD WITH MEP DRAWINGS.

BR

14' - 6" MIN

8"

PT-01A BR

ARCHITECT

G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; REF. ELECTRICAL AND STRUCTURAL DWGS.

NEW RETURN AIR GRILLE; COORD. W/ MEP DWGS; MOUNT AS HIGH AS POSSIBLE; B.O. GRILLE AT 14' - 6" AFF MIN. PAINT TO MATCH ADJ FINISH. PT-02

PT-02

19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

INTERIOR ELEVATIONS BOH DETAILS

A-305


2' - 2"

HOLD 2

PT-01D

4

3' - 6"

1' - 0"

6

PT-01D CAB

2' - 4"

GB

EXISTING WALL MOUNTED LAVATORY BY LL'S G.C.; EXPOSED PIPES SHALL BE INSULATED TO PROTECT AGAINST CONTACT; NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY; COORDINATE W/ MEP DWGS.

8

EXISTING AUTOMATIC FAUCET BY LL'S G.C.; COORDINATE W/ MEP DWGS.

9

EXISTING W.C. W/ OPEN-FACE ELONGATED TOILET SEAT BY LL'S G.C. COORDINATE W/ MEP DWGS.

10 EXISTING GRAB BARS BY LL'S G.C.; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQUIRED 11 EXISTING SURFACE MOUNTED TOILET PAPER DISPENSER BY LL'S G.C.; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D

SCALE: 1/2" = 1'-0"

22 EXISTING COAT HANGER BY LL'S G.C; G.C. TO PROVIDE IN-WALL BLOCKING AS REQ'D

(15" MIN)

1' - 6"

2' - 10"

3' - 5" 11"

SCALE: 1" = 1'-0"

EXISTING ADA GRAB BARS

MR

EXISTING RESTROOM MIRROR

SD

18"W X 36"H

EXISTING SOAP 6 1/8"L x 7"W x 3 5/16"D DISPENSER EXISTING RECESSED 19"H X 13"W X 4 1/4"D PAPER TOWEL DISPENSER EXISTING TOILET PAPER 6"W X 4 1/4"D X 2 3/4"H HOLDER

TD TPH

LANDLORD

BOBRICK

MODEL 23" x 23" 2 DOOR WALL MOUNT CABINET B-233

LANDLORD

BOBRICK

B-6806-18, B-6806-36, B-6806-42

LANDLORD

MANUFACTURER TOPEAKMART

BOBRICK

B-165 1836

LANDLORD

BOBRICK

B-4112

LANDLORD

BOBRICK

B-35903

LANDLORD

BOBRICK

B-264

FINISH WHITE

STAINLESS STEEL POLISHED STAINLESS STEEL BRUSHED STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL CHROME

QTY NOTES / REMARKS 1 FINISH: WHITE; G.C. TO PROVIDE AND INSTALL, CENTERED ABOVE W.C. AT 4'-3" AFF EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS

EX EX EX EX

3/4"

DESCRIPTION EXISTING RESTROOM SINK

PL.02

EXISTING RESTROOM SINK 2 "W X 5 1/2"D X 6 3/4"H FAUCET EXISTING RESTROOM 17 1/2"W X 30 5/8"D X 30 TOILET 11/16"H

PL.03 PL.04

SERVICE SINK

PL.05

SERVICE SINK FAUCET

PL.06

WATER COOLER

DIMENSION 20 1/2"W X 18 1/4"D

RESPONSIBILITY MANUFACTURER LANDLORD AMERICAN STANDARD

MODEL LUCERNE 0356.041

FINISH WHITE

QTY EX

GYP. CEILING PT-01C

CHROME

EX

LANDLORD

AMERICAN STANDARD

ASTUTE VORMAX 727AA.121

WHITE

EX

21"W X 21 1/2"D X 44 1/2"H 8" SPREAD

G.C.

TURBO AIR

TSA-1MOP

1

G.C.

B-0674-RGH

1

COORD. W/ MEP DWGS.

11 3/4"W x 14 1/2"D x 50"H

G.C.

T&S BRASS AND BRONZE WORKS, INC. QUENCH

STAINLESS STEEL CHROME

G.C TO SPECIFY RIGHT HANDED LEVER; G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. COORD. W/ MEP DWGS.

Q7 FREESTANDING

BLACK

1

COORD. W/ MEP DWGS.

P-4 R-1

MODEL APR-25-LC-UI

FINISH WHITE

QTY 1

11W

G.C.

AAMSCO

LED50SYM-24K-PC

1

17W

G.C.

SOLAIS LIGHTING

XR3NC-D-XM20-30K-1450-WH/WH

POLISHED CHROME WHITE

C-02

DESCRIPTION PAINTED WOOD WALL BASE EXISTING CONCRETE PREP FOR CUSTOM FINISH

LOCATION RESPONSIBILITY RESTROOM WALL BASE G.C.

RESTROOM FLOOR

MANUFACTURER G.C. G.C. TENANT'S

LANDLORD / G.C.

UNCONVENTIONAL FLOORING

PT-01C PT-01D

INTERIOR PAINT INTERIOR PAINT

RESTROOM CEILING RESTROOM WALL

G.C. G.C.

BENJAMIN MOORE BENJAMIN MOORE

PT-01E

INTERIOR PAINT

RESTROOM DOOR/ TRIM

G.C.

BENJAMIN MOORE

R-1

EM-1 16

STAMP

19

CLG

SD

B-01

PAINTED WOOD TRIM FOR WALL BASE BY RETAIL TENANT'S G.C., AT RESTROOM

3

EQ

B-01 TRIM PROFILE

2

SCALE: 6" = 1'-0"

C

NOTES / REMARKS G.C. TO PAINT TO MATCH ADJ. FINISH

B

20' - 3 5/8" 5' - 7 3/4"

V.I.F. 7' - 11 3/8"

6' - 8 1/2"

HOLD

HOLD

EQ

EQ

EQ

RESTROOM REFLECTED CEILING PLAN SCALE: 1/2" = 1'-0"

A

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019

MTD. @ 6-8" AFF CENTERED ABOVE MIRROR

DRAWN BY: RA, NK

2

RESTROOM FINISHES FINISH TAG A B-01

R-1

ST

NOTES / REMARKS G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. COORD. W/ MEP DWGS.

SELECTRONIC 6055.102

MANUFACTURER EVENLIGHT-APERION

20

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS

AMERICAN STANDARD

RESPONSIBILITY G.C.

21

9' - 0" AFF

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS RECESSED INTO WALL

LANDLORD

W/V 25W

RESTROOM

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS

RESTROOM LIGHTING FIXTURES DESCRIPTION SURFACE RECESSED EMERGENCY LIGHT ALINEA LINEAR WALL SCONCE 3"Ø DIMMABLE LED RECESSED DOWNLIGHT

3/8"

FINISHES PAINT GRADE POPLAR; REF. PLAN FOR PAINT FINISH

NOTES / REMARKS REFER TO DETAIL 6 FOR TRIM PROFILE

EXISTING CONCRETE FLOOR TO REMAIN LL'S G.C. TO PREP FLOOR PER TENANT'S VENDOR RECOMMENDATIONS FOR NEW GRIND, STAIN, SEAL AND POLISH BY TENANT'S G.C.; CUSTOM STAIN COLOR: CHARCOAL; FINISH: SEMI-GLOSS SIMPLY WHITE OC-117; FLAT COROTECH PRE-CATALYZED WATERBRONE EPOXY V342; COLOR: SIMPLY WHITE OC-117; FINISH: EGGSHELL; LOW VOC COROTECH ACRYLIC DTM ENAMEL - V331; COLOR: SIMPLY WHITE OC-117; FINISH: SEMI-GLOSS; LOW VOC

LL'S G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT; ADD. ALT IF NOT PROVIDED BY LANDLORD, TENANT'S G.C. TO PROVIDE. REF. LANDLORD DWGS. FOR REQUIRED SLAB IN-FILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL

1' - 4"

17

06

PLUMBING FIXTURES TAG PL.01

P-4

18

EQ

GB

1 1/4" W x 1 1/8" D x 1 1/4" H 18"L, 36"L, 42"L

RESPONSIBILITY G.C.

EQ

COAT HOOK

DIMENSIONS 23.2"W x 12.2"" x 23.4

19 NEW SUPPLY GRILLE BY TENANT'S G.C.; COORD. W/ MEP DWGS; LL'S G.C. TO FINISH TO MATCH ADJ. CLG

21 CONCEALED SPRINKLER HEAD W/ WHITE COVER BY LL'S G.C.; COORD. W/ MEP & APPROVED SPRINKLER DWGS.; TENANT'S G.C. TO RELOCATE AS REQUIRED FOR NEW GWB CEILING LAYOUT

ENLARGED RESTROOM PLAN

EQ

CH

17 NEW ALINEA LINEAR LIGHT FIXTURE BY TENANT'S G.C.; CENTER ABOVE RESTROOM MIRROR @ 6'-8" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN POLISHED CHROME; LL'S G.C. TO PROVIDE WHIP CONNECTION @ 6-8"AFF AND PAINT EXPOSED WHIP TO MATCH ADJ. FINISH

20 NEW GWB CEILING @ RESTROOM CEILING BY TENANT'S G.C., TENANT'S G.C. TO DEMO EXISTING ACT CEILING AND 2X4 GRID LIGHT; PAINT TO MATCH PT-01C ; (DEDUCT ALT: EXISTING ACT CEILING AND LIGHT TO REMAIN; CONFIRM WITH TENANT PRIOR TO DEMO)

SCALE: 1/2" = 1'-0"

4

HOLD

EQ

DESCRIPTION WALL CABINET

14 NEW G.F.I. DUPLEX MOUNTED @ 46" AFF W/ WHITE COVER PLATE BY LL'S G.C.; COORD. W/ MEP DWGS

18 EXISTING EXHAUST FAN AND GRILLE BY LL'S G.C.; COORD. W/ MEP DWGS; LL'S G.C. TO FINISH WHITE TO MATCH ADJ. CEILING COLOR; TENANT'S G.C. TO RELOCATE AS REQUIRED FOR NEW GWB CEILING LAYOUT

ADA RESTROOM WEST

HOLD

3/8"

TAG CAB

13 EXISTING RECESSED PAPER TOWEL DISPENSER BY LL'S G.C.; PROVIDE CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D

16 CEILING MOUNTED FIRE ALARM STROBE BY TENANT'S G.C.; FINISH WHITE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS

9

RESTROOM ACCESSORIES

12 EXISTING MIRROR; SURFACE MOUNTED & CENTERED ABOVE LAVATORY BY LL'S G.C.; REFLECTIVE SURFACE SYMBOL TAG (NOT FRAME) TO BE MOUNTED AT 40" AFF MAX; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT EM-1 PLYWOOD BLOCKING AS REQ'D

15 NEW SWITCH / OCCUPANCY SENSOR MOUNTED W/ WHITE COVER PLATE @ 46" AFF BY TENANT'S G.C.; COORD. W/ MEP DWGS

PL.03

7' - 0"

EQ

EXISTING CONCRETE FLOOR TO REMAIN; LL'S G.C. TO PREP FLOOR PER TENANT'S VENDOR RECOMMENDATIONS FOR NEW GRIND, STAIN, SEAL AND POLISH BY TENANT'S G.C.; CUSTOM STAIN COLOR: CHARCOAL; FINISH: SEMI-GLOSS; LL'S G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT; ADD-ALT: IF IN-FILL NOT PROVIDED BY LANDLORD; TENANT'S G.C. TO PROVIDE; REF. LANDLORD DWGS. FOR REQUIRED SLAB IN-FILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS

5

11

9"

EQ

6

7

AND REPLACE HARDWARE W/ BLACK

5

5' - 7 3/4"

CHECKED BY: JSP

HOLD

TENANT'S G.C. TO PAINT EXISTING DOOR BY LL'S G.C. PT-01E HARDWARE; REF. DOOR SCHEDULE

ADA RESTROOM SOUTH

8

TPH

0' - 0" A.F.F. FINISHED FLOOR

7' - 4"

5

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

EX-03

3 5/8"

AT RESTROOM FURNISHED AND INSTALLED BY TENANT'S G.C.; TENANT'S G.C. TO

22

SCRIBE

NEW WALL BASE B-01 PAINT PT-01E

0' - 0" A.F.F. FINISHED FLOOR

4"

4

10

1"

LL'S G.C. TO PREP ALL WALLS TO RECEIVE NEW PAINT FINISH AND ENSURE LEVEL 4 FINISH, TENANT'S G.C. TO PAINT ALL WALLS PT-01D

OSBORN

TYP.

30"x48" CLEAR WHEELCHAIR SPACE

5"

3

TM

30" CLEAR

60"Ø TURNING SPACE

7' - 6 3/8"

LL'S G.C. TO USE WATER-RESISTANT GYP. BOARD AT ALL WET AREAS

B-01 PT-01E

B-01 PT-01E

11. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND PLUMBING FIXTURES AND RESTROOM ACCESSORIES; COORD. LOCATIONS WITH MANUFACTURER'S INSTALL RECOMMENDATIONS.

2

HOLD

7" MIN 9" MAX

10. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS.

LEASE LINE

TYP.

STRUCTURAL ENGINEER

60" CLEAR

9. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING.

1

TYP.

OS

C-02

6"

GB

TYP.

1' - 4"

LICENSE # C-4550

60 INCH CLEAR HOLD

2' - 5 1/8"

1' - 6"

8. ALL MATERIALS AND FINISHES MUST BE FIRE-RATED AND HAVE FLAME RESISTANCE COMPLYING WITH LOCAL & STATE CODES.

ENLARGED RESTROOM PLAN KEY NOTES:

10

4' - 6 1/8" ADA RESTROOM 07 WALL PT-01D BASE B-01/PT-01E FLOOR C-02

GB 10

7. G.C. TO SUBMIT SAMPLES OF ALL FINISHES FOR FINAL APPROVAL PRIOR TO ORDERING OF MATERIALS OR INSTALLATION.

15. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.

3

6

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

9' - 0" A.F.F. RESTROOM CLG

1' - 2"

8

1' - 6"

6. ALL CONCRETE FINISHES TO FOLLOW DESCRIPTION PROVIDED IN FINISH SCHEDULE

14. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES.

11

SCALE: 1/2" = 1'-0"

5. ALL INTERIOR GWB PAINT TO BE SPRAY APPLIED AND BACKROLL FINISHED. SAMPLE TO BE PROVIDED TO ARCHITECT FOR APPROVAL. G.C. AND F.C. TO COORDINATE AND MATCH PAINTED FINISHES.

A-306

15

RETAIL TENANT

ADA RESTROOM EAST

9' - 0" A.F.F. RESTROOM CLG

4. ALL FINISHING AND PAINTING REQUIREMENTS BE AS PER FINISH SCHEDULE, ELEVATIONS AND SPECIFICATIONS.

5

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

HOLD

0' - 0" A.F.F. FINISHED FLOOR

3. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP.

13. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS.

7

7' - 4"

6

SCALE: 1/2" = 1'-0"

2. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS.

12. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN FIRE-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.

HOLD

B-01 PT-01E

CASE ENGINEERING, INC.

DOOR

7

13

TPH

ADA RESTROOM NORTH

MEP ENGINEER

3' - 0"

9

SD TD

HOLD

1. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES.

PL.03

PL.01

1' - 2"

ENLARGED RESTROOM PLAN GENERAL NOTES:

11

7

12" CLEAR

TPH

0' - 0" A.F.F. FINISHED FLOOR

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

PL.01

1' - 0 7/8"

PARTITION TYPE TAG

7

GFI @ 46" AFF

18" CLEAR

FIXTURE TAG

PL.01

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

12 1

56" CLEAR

B-01 PT-01E

DOOR TO VESTIBULE EX-03

PL.02

2' - 4"

7

MR

PL.02

OWNER'S REPRESENTATIVE

1' - 0"

6' - 8"

10

8

15

MIN.

FINISH TAG

13

TD

3' - 6"

1

14

CAB ABV

10

PT-01E

HOLD

WHITE

GB

MIN.

PL.03

22 13

8

MIN

9

3' - 10 1/8"

3' - 0"

OCCUPANCY SENSOR/SWITCH

2' - 2"

8

3' - 0"

3' - 10"

OS

MR

14

6" HOLD

5' - 3"

FINISH ROOM TAG

1

TD

12

3' - 0"

HOLD

GB

6' - 11 1/8"

A

WALL MOUNTED 20A GFI GROUNDED DUPLEX WHITE RECEPTACLE W/ GROUND FAULT INTERRUPTER

12

PL.02

1' - 6"

X.01

RCP ROOM TAG

MR

HOLD

X-01

EXHAUST FAN & GRILLE

CAB

3' - 10"

WHITE

REF. MEP

SUPPLY GRILLE

HOLD 6"

(48" MAX)

WHITE

REF. MEP

7 1/4" PT-01E

3' - 7"

1

ARCHITECT

HOLD 7' - 4 1/8"

17

34" HOLD

WHITE

7' - 11 3/8"

PT-01D

CLEAR

CONCEALED SPRINKLER HEAD

1' - 4"

9"

1

17

4' - 6 1/8"

27" MIN.

WHITE

1' - 6"

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT AT 6'-8" AFF

6' - 8"

SMOKE DETECTOR CEILING MOUNTED

B.O. REFLECTIVE SURFACE

PARTITION BY TENANT'S G.C.

SD

PT-01D

1

40" MAX

FIRE ALARM STROBE WHITE CEILING MOUNTED

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT AT 6'-8" AFF

34" HOLD

ST CLG

6"

ROOM NAME 01 WALL WALL FINISH BASE BASE FINISH FLOOR FLOOR FINISH

QTY

PARTITION BY LANDLORD'S G.C.

CONCRETE FLOOR

ROOM NAME 01 TYPE FINISH 0'-0" AFF

FINISH

HOLD

SYMBOL DESCRIPTION

1' - 6"

DESCRIPTION

2' - 10"

HATCH / SYMBOL

9' - 0" A.F.F. RESTROOM CLG

48" CLEAR

9' - 0" A.F.F. RESTROOM CLG

RESTROOM SYMBOL / HATCH LEGEND

AREA: 1,400 SF

#

7' - 0"

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

4 A-306

1' - 4 1/4"

ENLARGED RESTROOM PLANS & ELEVATIONS 10

LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL

1

RESTROOM KEY PLAN SCALE: 1/8" = 1'-0"

A-306


CURTAIN RODS BY F.C.

4" X 3" X 30" L-BRACKET MT-01

2 1/2" HOLD 1 1/2"

1 1/2"

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A

7' - 4 1/2"

3' - 6" EQ

CURTAIN AND RINGS BY CURTAIN VENDOR; G.C TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM

2"

1 1/2"

3' - 6"

DASHED LINE INDICATES 3/4" FRT PLYWOOD IN-WALL BLOCKING

1 1/2"

EQ

1' - 0"

3' - 9"

2"

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A

1 1/2"

1 1/2"

HANG BAR BY F.C. SECURED TO FITTING ROOM PANEL BY G.C. MT-01

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A

4' - 2 1/2" HOLD 3' - 7"

2 1/2"

2 1/2"

CURTAIN AND CURTAIN RINGS BY CURTAIN VENDOR; G.C. TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

OWNER'S REPRESENTATIVE

1 1/2"

CURTAIN AND CURTAIN RINGS BY CURTAIN VENDOR; G.C. TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM 4' - 2 1/2"

ARCHITECT

4" X 3" X 30" LBRACKET MT-01

CURTAIN RODS BY F.C. FITTING ROOM HOOKS BY F.C.

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MT-01

A.05

A.04

6"

CASE ENGINEERING, INC.

EQ.

A.05

FREE-STADING FITTING ROOM FURNISHED BY F.C INSTALLED BY G.C.; G.C TO PROVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C

2 A-400

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A 1' - 10 1/2"

HOLD

3' - 7 1/2"

1' - 10 1/2"

HOLD

HOLD

BONOBOS G.C. TO SECURE FITTING ROOM UNIT TO WALL WITH 3" x 4" x 30" PREDRILLED METAL BRACKETS MT-01 BY F.C.

2 1/2" HOLD

CONTINUOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C., REF. ELEVATIONS FOR LOCATIONS 7' - 7 1/2" A.F.F. T.O. FITTING ROOM UNIT STAMP

A.05

A.05

5"

A.04

PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH

5"

2' - 5"

MT-01

TYP.

7' - 2"

SCALE: 1" = 1'-0"

7' - 2" A.F.F.

V.I.F.

A.04

HANG BAR BY F.C. SECURED TO FITTING ROOM PANEL BY G.C.

BLACK LEVELERS

FITTING ROOM - SECTION W/ HOOKS

EQ.

5/8" TYPE 'X' GYP. BOARD

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

5' - 0" A-400

EQ.

CONTINUOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C., REF. ELEVATIONS FOR LOCATIONS

STRUCTURAL ENGINEER

6 A-400

1 1/2"

HOLD

1

4' - 2 1/2"

4" X 3" X 30" L-BRACKET MT-01

HOLD

7' - 7 1/2"

SCALE: 1" = 1'-0"

LICENSE # C-4550

OSBORN

TYP.

2

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

TM

1 A-400

3' - 10 1/2"

FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C. . INSTALLED BY G.C; G.C. TO RPOVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01

BLACK LEVELERS

FITTING ROOM - FRONT ELEVATION PRE-DRILLED L-ANGLE FOR WALL CONNECTION MT-01

WD-01

2 1/2" HOLD

SCALE: 1" = 1'-0"

F.22

4' - 0"

4

HOLD

7' - 6"

F.22

BLACK LEVELERS

FITTING ROOM - SECTION W/ HANGBAR

5' - 0"

5' - 0"

F.22

7' - 7 1/2"

WD-01

TYP.

7' - 2"

6' - 10"

HOLD

7' - 2"

WD-01

TYP.

5' - 0"

HOLD

HANG BAR BY F.C. SECURED TO FITTING ROOM PANEL BY G.C. MT-01

WD-01

7' - 6"

7' - 7 1/2"

A.04

6"

A.05

A.04

6

EQ.

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

EQ.

MEP ENGINEER

RETAIL TENANT

2' - 5"

F.22

TYP.

EQ.

FITTING ROOM HOOKS BY F.C. MT-01

C.L. OF LINEAR LIGHT

A-400

EQ.

WD-01

5

EQ.

PARTITION AS SCHEDULED; REF. A-100 & A-600 FOR PARTITION TYPE AND SCHEDULE.

F.22

1 1/2"

FB.01

3' - 6"

F.22

1 1/2"

CLEAR

3' - 6"

1 1/2"

CLEAR

2"

7' - 4 1/2"

HOLD

HOLD

FITTING ROOM UNIT BY F.C. WD-01 MT-01

FB.01

CURTAIN AND RINGS BY CURTAIN VENDOR

WALL BASE AS SCHEDULED; REF. A-104 & A-600 FOR LOCATION AND DETAILS.

BLACK LEVELERS FINISHED FLOOR AS SCHEDULED; REF. A-104

FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C. . INSTALLED BY G.C; G.C. TO RPOVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01

5

FITTING ROOM - SIDE ELEVATION SCALE: 1" = 1'-0"

DATE: 02/27/2019 DRAWN BY: RA, NK AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

FINISHED FLOOR

FREE-STANDING FITTING ROOM DETAILS

BLACK LEVELERS

3

FITTING ROOM - PLAN SCALE: 1" = 1'-0"

DATE 02/27/2019 03/04/2019

0' - 0" A.F.F.

CURTAIN AND CURTAIN RINGS BY CURTAIN VENDOR; G.C. TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM F.22

PROJECT NO.: 218259

CHECKED BY: JSP

4 A-400

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

1

FITTTING ROOM UNIT OFFSTAND DETAIL SCALE: 3" = 1'-0"

A-400


ARCHITECT

DUCT BEYOND; REF. MEP DRAWINGS PLENUM BOX BEYOND; REF. MEP DRAWINGS

EXISTING STRUCTURE ABOVE TO REMAIN; G.C. TO ENSURE MAINTENANCE OF FIRE-RATING AND FIRE-PROTECTION

12 GAUGE HANGER WIRE SUPPORT DIFFUSER AND PLENUM BOX FROM STRUCTURE ABOVE

3 5/8" 18 GA. METAL STUD BRACING TO STRUCTURE AT 4'-0" O.C. MAX, ALTERNATING SIDES, LENGTH OF BRACING MAY NOT EXCEED 16'-0"

5/8"THK TYPE 'X' GYP. BOARD

LIGHT SHIELD CONTINUOUS ALONG SLOT EXCEPT AT ACTIVE PLENUM BOX LOCATIONS

3 5/8" 18 GA. METAL STUD BRACING TO STRUCTURE AT 4'-0" O.C. MAX, ALTERNATING SIDES, LENGTH OF BRACING MAY NOT EXCEED 16'-0"

SUSPENDED CEILING SYSTEM HARD CEILING ATTACHMENT CLIPS

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

OWNER'S REPRESENTATIVE

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

5/8"THK TYPE 'X' GYP. BOARD AT CEILING

4" x 4" x 20 GA. CLIP ANGLE, FASTEN TO EACH BRACE AND RUNNER WITH TEK SCREWS (3 PER LEG, TYP)

REF. RCP B.O. CEILING

10" HOLD

1"

1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS; TAPE AND SAND PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED

SLOT

12

METAL STUD FRAMING AS SCHEDULED; SEE CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600

TAPED-IN LINEAR SLOT DETAIL

CASE ENGINEERING, INC.

4 x 2" TEK SCREWS AT EACH BOTTOM FLANGE

DRYWALL CORNER BEAD

8

SCALE: 3" = 1'-0"

MEP ENGINEER

METAL TRACK AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600

TYP. GYP. BOARD CORNER SCALE: N.T.S.

4" x 4" x 20 GA. CLIP ANGLE AT EACH BRACE

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550

3

TYP. BRACING AT STRUCTURE

STRUCTURAL ENGINEER

SCALE: N.T.S. TM

2"THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF EXISTING RATED CEILING AS REQ'D

1 LAYER OF 5/8" TYPE 'X' GYP. BOARD; REF. FINISH PLAN FOR WALL FINISH

6" MIN.

BLOCKING AS REQ'D 5/8" TYPE "X" GYP. BOARD PT-01A

MOUNTING RAIL BETWEEN 6" METAL STUDS; REFER TO FIXTURE CUT SHEET

CURTAIN CARRIER PROVIDED BY VENDOR, FOREST CS TRACK 25010, 0.8" x 0.8"; FINISH WHITE

13/16"

NOT USED

CEILING AS SCHEDULED; REF. RCP A-102 METAL STUD FRAMING AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600

7' - 0" A.F.F. B.O. OPENING SHIM AS REQUIRED

EXISTING 6" METAL STUDS SPACED AT 16" O.C. TO REMAIN

EQ

RECESSED EM LIGHT DETAIL AT 1-HR RATED WALL

CURTAIN FABRIC PROVIDED BY VENDOR WITH CS STOP CARRIER 25102 FB-01

PARTITION THICKNESS

7

SCALE: 3" = 1'-0"

EQ

REF. PLAN

FIRESTOPPING AS REQUIRED

RECESSED DRAPERY TRACK DETAIL SCALE: 6" = 1'-0"

ATTACHMENT TO STRUCTURAL SUPPORT TO COMPLY W/ LOCAL CODE

45°

45°

12 GA. VERTICAL HANGER WIRE AT 4' - 0" O.C. EACH WAY AND 8" MAX FROM ALL PERIMETER EDGES

2" MAX 45°

2" MAX

NOT USED

45°

45°

SUSPENSION CROSS TEES SPACED AT 2' - 0" O.C. MAX.

45° 45°

2" MAX 2" MAX

6

SCALE: N.T.S.

3 A-500

SUSPENSION CROSS TEES SPACED AT 2' - 0" O.C. MAX.

5/8"THK TYPE 'X' GYP. BD. W/ FINISH AS SCHEDULED; REF. FINISH PLAN A-104 2 A-500

DRYWALL SUSPENSION TEES

4' - 0" O.C., TYP.

AT PERIMETER 5/8"THK TYPE 'X' GYP. BOARD 2" MIN WALL ANGLE MOLDING; GRID MEMBERS ATTACHED TO WALL MOLDING @ 2 ADJACENT WALLS USING POP RIVETS OR SCREWS

NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05

SCALE: N.T.S.

STAMP

4. ALL STUDS SHALL BE ''C' TYPE WITH FLANGE STIFFENERS 5. THE MATERIALS AND DETAILS SHOWN ARE FOR TYPICAL INSTALLATION. WHERE THE MANUFACTURER RECOMMENDS OR LOCAL ORDINANCES AND/OR CODES ARE MORE RESTRICTIVE, THE HIGHER STANDARD SHALL PREVAIL AND APPLY \

TYPICAL FASTENERS: 1. STEEL STUDS TO STEEL STUDS OR TRACKS: #8-18 x 1/2" TEKS/2 W/ PHIL PAN-HEAD FOR 25 GA. OR 20 GA. #10-16 x 9/16" TEKS/3 W/ PHIL PAN-HEAD FOR INTERCONNECTION OF 18 GA. OR 16 GA.

WALL BASE AS SCHEDULED; REF. FINISH PLAN

3. STEEL STUDS OR TRACKS TO STRUCTURAL STEEL (WIDE FLANGE BEAMS, COLUMNS, GIRDERS, STEEL TUBE SHAPES E.T.C.): TEKS/3 OR TEKS/4 GA. AND LENGTH AS REQ'D FOR THE COMBINED THICKNESS OF THE MATERIAL TO BE DRILLED 4. PLYWOOD TO STEEL STUDS: #10-24 x 3/4" TEKS/3 (PLYMETAL TEKS) WITH THIN WAFER HEAD 5. GYPSUM BOARD TO STEEL STUDS: #7 x 1/4" TYPE 'S' BUGLE HEADS SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 25 GA. OR 20 GA. METAL STUDS #6 x 1/2" TYPE 'S' BUGLE HEADS SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 18 GA. OR 16 GA. METAL STUDS

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

EXISTING FLOOR SLAB

ACOUSTIC / FIRE CAULKING AS REQ'D

FASTEN WALL ANGLE TO SUSPENSION TEES

9

HORZ. BRIDGING TYP.

2" WALL ANGLE

SUSPENSION CROSS TEES SPACED AT 2' - 0" O.C. MAX.

3. ALL STUD WALLS AND PARTITIONS SHALL HAVE CONTINUOUS LINES OF BRIDGING SPACED AT 4'-0" O.C. THE BRIDGING SHALL BE SECURELY FASTENED TO THE STUDS WITH EITHER WELDS OR SCREWS

2. STEEL STUDS OR TRACKS TO WOOD PURLINS, GIRDERS, AND BEAMS #14-10 x 1/2" H.W.H. TYPE 'S' METAL-TO-WOOD TEKS

8" MAX

SUSPENSION MAIN TEES SPACED AT 4' - 0" O.C. MAX.

TYP. SUSPENDED GYP. BOARD CEILING

METAL STUD FRAMING AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600

4 A-500

12 GAUGE HANGER WIRE

FASTEN WALL ANGLE TO WALL FRAMING, TYP.

2 1/2" x 18 GA 3 5/8" x 18 GA 6" x 18 GA 6" x 18 GA

6. G.C. TO COORDINATE ANY AND ALL REQUIRED SPECIAL INSPECTIONS OF CEILING AND PARTITION FRAMING WITH LOCAL CODE OFFICIAL

NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05

SCALE: N.T.S.

MINIMUM OF 3 TIGHT TURNS AT ALL WIRES.

2 1/2" x 18 GA 3 5/8" x 18 GA 6" x 18 GA 6" x 18 GA

TOP TRACK 8' - 0" SPAN 11' - 0" SPAN 2 1/2" x 18 GA NOT APPLICABLE 3 5/8" x 18 GA 3 5/8" x 18 GA DL 6" x 18 GA 6" x 18 GA 6" x 18 GA 6" x 18 GA DL

2. ALL SUSPENDED WALLS SHALL HAVE GYPSUM BOARD THAT EXTENDS AT LEAST 6" ABOVE THE SUSPEND CEILING (UNLESS SPECIFICALLY DETAILED OTHERWISE)

3 5/8" 18 GA. METAL STUD BRACING TO STRUCTURE AT 4'-0" O.C. MAX, ALTERNATING SIDES, LENGTH OF BRACING MAY NOT EXCEED 16'-0"

TYP. COMPRESSION STRUT SUSPENSION

12 GA VERTICAL HANGER WIRE @ 4' - 0" O.C. EACH WAY. AND 8" MAX FROM ALL PERIMETER EDGES.

AS NOTED UP TO 16' - 0" 16' - 0" TO 20'-0" 20' - 0" TO 24'-0"

BOTTOM TRACK

1. ALL LIGHT GA. METAL STUD WALLS AND PARTITIONS REQUIRE 5/8"THK TYPE 'X' GYPSUM BOARD ON BOTH SIDES FOR THE FULL HEIGHT OF THE STUDS (UNLESS SPECIFICALLY DETAILED OTHERWISE

TYPICAL 12 GA. HANGER WIRE SPACED AT 4'-0" O.C. MAX.

NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05

TYP. COMPRESSION STRUT CEILING ATTACHMENT

8" MAX

SUSPENSION MAIN TEES SPACED AT 4' - 0" O.C. MAX.

SCALE: N.T.S.

PARTITION FRAMING SCHEDULE NOTES:

(4) SPLAY WIRES AT 45° PARALLEL TO CROSS TEES

NOTE: MECHANICAL EQUIPMENT AND LIGHT FIXTURES MUST BE CONNECTED TO ONE (1) VERTICAL 12 GA. WIRE ATTACHED TO OPPOSING CORNERS ALONG THE FIXTURE'S DIAGONAL. THESE WIRES MAY BE SLACK (UBC STD. NO 25.213.25214

10

EXISTING STRUCTURE ABOVE TO REMAIN; G.C. TO ENSURE MAINTENANCE OF FIRE-RATING AND FIRE-PROTECTION

HORIZONTALLY

5/8"THK TYPE 'X' GYP BOARD

NOT USED

TYP. HORZ. BRIDGING

HEIGHT

(4) SPLAY WIRES AT 45° PARALLEL TO CROSS TEES

SUSPENSION MAIN TEES SPACED AT 4' - 0" O.C. MAX.

3/4" THIN WALL ELEC. CONDUIT W./ SLOT AT END TO FIT OVER CEILING RUNNER

2

PARTITION FRAMING SCHEDULE:

12 GA. VERTICAL HANGER WIRE WITHIN TUBING, LEVEL CEILING PRIOR TO SETTING STRUT COMPRESSION STRUT SPACED AT 12'-0" O.C. MAX.

DRILL 3/32" HOLE AND INSTALL 1/8"Ø BOLT AND LOCKING NUT

45°

SCALE: N.T.S.

ANGLE CLIP PINNED AND BOLTED TO COMPRESSION STRUT

12 GA. VERTICAL HANGER WIRE WITHIN TUBING, LEVEL CEILING PRIOR TO SETTING STRUT

4" MIN.

INSTALL COMPRESSION STRUT IN COMPLIANCE WITH LOCAL CODE, STRUTS TO BE 12' - 0" O.C. EACH DIRECTION

TYP. BRACING AT PARTITION

MIN.

1/2"Ø THIN WALL ELEC. CONDUIT OR APPROVED EQUIVALENT (EXTEND TUBE TO BE TIGHT TO SUSPENDED CEILING & STRUCTURE ABOVE, THEN INSTALL BOLT TO SECURE IN PLACE)

4

6"

11

13/16"

METAL STUD FRAMING AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600

5/8"THK TYPE 'X' GYP. BOARD W/ FINISH AS SCHEDULED; REF. FINISH PLAN A-104

5/8" TYPE "X" GYP. BOARD PT-01A

1 LAYER OF 5/8" TYPE 'X' GYP. BOARD; G.C. TO PROVIDE FIRE CAULKING AS REQ'D TO MAINTAIN 1HR FIRE RATING

3/4" 16 GA. COLDROLLED CHANNEL SPACED AT 4'-0" O.C. HORIZONTALLY

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

3 5/8" METAL STUD FRAMING

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

RETAIL TENANT

FLUSH MOUNTED EMERGENCY LIGHT; PAINT TO MATCH ADJ FINISH, REF. FINISH PLAN

OSBORN

1 1/2" x 3" 16 GA. CHANNEL CLIP ANGLE, FASTEN TO STUD AND CHANNEL W/ (4) 5/8" #5 TEK SCREWS ALT. FASTENING (3) 3/4" WELDS (AT 3 DIFFERENT PLACES)

2" MIN WALL ANGLE

5

CAULK WHERE WALL ANGLE MEETS WALL J-BEAD AT ALL GYP. BOARD CEILING EDGES

NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05

TYP. SUSPENDED CEILING T PERIMETER SCALE: N.T.S.

CONTINUOUS BOTTOM TRACK W/ 'HILTI' PNEUMATIC SHOT PINS .145Ø W/ DISCS @ 16" O.C. TYP.

1

TYP. BRACED PARTITION SCALE: N.T.S.

CONSTRUCTION & CEILING DETAILS

A-500


PAINTED WOOD BASE. REF. A-104; FINISH TO MATCH B-01 PT-01B

HOLD

EQ

PAINTED WOOD BASE. FINISH TO MATCH B-01 PT-01B

EQ

4' - 5" HOLD

1' - 2 1/2"

3' - 2 1/2" 11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. EXTEND TO UNDERSIDE OF DECK

1' - 4 5/8" VIF

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. BEYOND

A

2' - 5"

EXISTING CONCRETE COLUMN. REF. STRUCTURAL DWGS

5/8" TYPE "X" GYP. BOARD.

10

OWNER'S REPRESENTATIVE

1' - 4 5/8"

1 3/4"

1' - 4 5/8"

5/8" 1 7/8"

ARCHITECT

B

ALIGN FACE OF GYP. BOARD W/ COLUMN 'A' AT STOREFORNT BEYOND

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

5/8" TYPE "X" GYP. BOARD.

FIRE RATED WOOD BLOCKING AS REQ'D.

10

EXISTING CONCRETE COLUMN. REF. STRUCTURAL DWGS

FIRE RATED WOOD BLOCKING AS REQ'D.

2 x 12 DECORATIVE BEAM; COORD. EXTENTS W/ RCP, FINISH TO MATCH WD-02

12

12' - 8 1/4" A.F.F.

4' - 10"

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. EXTEND TO UNDERSIDE OF DECK

COLUMN B DETAIL

HOLD

CASE ENGINEERING, INC. 3' - 9"

EXISTING CONCRETE BEAM TO REMAIN

MEP ENGINEER

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

LICENSE # C-4550

2' - 4 3/8"

PT-02

HOLD

BLOCKING AS REQUIRED

SCALE: 1 1/2" = 1'-0"

STRUCTURAL ENGINEER

TM

T.O. BEAM

3' - 5 3/8"

OSBORN

WD-02

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C.

BLOCKING AS REQUIRED

(1) LAYER 5/8" TYPE 'X' GYP. BOARD EXTENDED TO STRUCTURE ABOVE ON METAL FRAMING. G.C. TO PAINT PT-02 ABOVE 11-9" AFF PAINT LINE; G.C. TO PAINT PT-01A BELOW PAINT LINE

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. BEYOND

PT-01A

1 1/2"

5/8" TYP. 'X' GYP. BOARD BY G.C. AS REQ'D TO INSTLALL CONCEALED IN-WALL BLOCKING

NEW 2 X 12 DECORATIVE BEAMS; COORD. EXTENTS W/ RCP WD-02

5

DECORATIVE BEAM - WALL CONNECTION @ ENTRY

3

SCALE: 3" = 1'-0"

CONCELAED FASTENING OF WOOD BEAM TO WALL BLOCKING

DECORATIVE BEAM - WALL CONNECTION SCALE: 3" = 1'-0"

2

COLUMN A DETAIL SCALE: 1 1/2" = 1'-0"

19' - 9" V.I.F.

19' - 9" V.I.F.

B.O. EXISTING SLAB

B.O. EXISTING SLAB UNDERSIDE OF EXISTING SLAB

5 A-501

2 x 12 DECORATIVE BEAM; COORD. EXTENTS W/ RCP, FINISH TO MATCH WD-02

UNDERSIDE OF EXISTING SLAB

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EXTENDED TO STRUCTURE ABOVE ON METAL FRAMING (BEAM SIDE ONLY) G.C. TO PAINT WALL ABOVE PAINT LINE AT B.O. BEAM PT-02

PT-02

STAMP

PT-02

3"

3"

3"

PT-02 AT BEAM ENDS THIS SIDE ONLY 5"

EQ

A-501

LED TAPE LIGHTING (T-01) WITH ANGLE CHANNEL (TLACA6), CLIP MOUNTED ON PAINT GRADE PLYWOOD; G.C. TO INSTALL TAPE LIGHT IN 3 EQUAL SECTIONS; REF. RCP

(4) 1/2" Ø THRU BOLTS AND NUT WITH WASHERS AT EACH SIDE. POWDER-COATED TO MATCH 3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. EXTEND TO UNDERSIDE OF DECK

HOLD

PT-02

3/4" PAINT GRADE PLYWOOD PT-01C

CONTINUOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING

11' - 9" A.F.F.

1 3/8" HOLD

HOLD

SALES CEILING

SCALE: 3" = 1'-0"

AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

11' - 0" A.F.F. (1) LAYER 5/8" THK 'X' TYPE GYP. BOARD PT-01C

8" HOLD

DATE: 02/27/2019 DRAWN BY: NK, JO

11' - 0" A.F.F.

PT-01C

PROJECT NO.: 218259

CHECKED BY: JSP

BLOCKING AS REQUIRED

WOOD BLOCKING AS REQ'D

SECTION AT DECORATIVE BEAM

T.O WALL WASHER COVE

8"

9"

11' - 8" A.F.F.

EQ.

6" METAL STUD CEILING FRAMING SPACED AT 24" O.C.; BRACE TO DECK AS REQ'D

PT-01A

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

6" METAL STUD CEILING FRAMING SPACED AT 24" O.C.; BRACE TO DECK AS REQ'D

B.O. BEAM & PAINT LINE

EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRE-RATED AND WHERE DAMAGED PATCH AND RESEAL AS REQ'D TO RESTORE RATING

7 3/8"

4"

3

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C EXTEND TO UNDERSIDE OF DECK

FASTEN HANGER TO GYP. BOARD AND BLOCKING WITH BLACK SCREWS

WD-02

11 1/4"

WD-02

(1) LAYER FOR 5/8" TYPE 'X' GYP. BOARD EXTENDED TO STRUCTURE ABOVE ON METAL FRAMING AT EACH SIDE OF STUD, REF. A-100 & A-600 FOR PARTITION TYPE AND SCHEDULE. PAINT PT-02 ABOVE 11-9" AFF PAINT LINE; G.C. TO PAINT BELOW PAINT LINE

JOIST HANGER AT CONCEALED END OF DECORATIVE BEAM ONLY. POWDER-COATED TO MATCH PT-02

HOLD

3"

CONCEAL FASTENING OF WOOD BEAM TO WALL BLOCKING

T.O. BEAM

4"

EQ EQ

EQ.

EQ

12' - 8 1/4" A.F.F.

CONTINOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING

4

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

B.O. BEAM & PAINT LINE

RETAIL TENANT

EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRE-RATED AND WHERE DAMAGED PATCH AND RE-SEAL AS REQ'D TO RESTORE RATING

3/4"

11' - 9" A.F.F.

EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRE-RATED AND WHERE DAMAGED PATCH AND RE-SEAL AS REQ'D TO RESTORE RATING

V.I.F.

3/4" THK CONTINUOUS FRT PLYWOOD BLOCKING BY G.C.

5/8" TYPE "X" GYP. BOARD;

1' - 1"

CONTINUOUS 3/8" FRT PLYWOOD IN-WALL BLOCKING

ALIGN

SALES CEILING

6" HOLD

5/8"THK TYPE 'X' GYP. BOARD PT-01C

EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRERATED AND WHERE DAMAGED PATCH AND RE-SEAL AS REQ'D TO RESTORE RATING; G.C. TO PAINT PT-01A

1

WALL WASHER CEILING DETAIL SCALE: 3" = 1'-0"

CONSTRUCTION & CEILING DETAILS

A-501


ARCHITECT

13' - 6 3/4" A.F.F. T.O. EXISITNG PARAPET

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

12' - 3" A.F.F. ROOF

OWNER'S REPRESENTATIVE

EXIST. CONCRETE BEAM AND ROOF, SEE STRUCTURAL DWGS.

11' - 9" A.F.F. B.O. BEAMS

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

G.C. TO PROVIDE CONTINUOUS FIRE CAULKING AT TOP, BOTTOM AND EDGES OF PARTITION AT BOTH SIDES AND ALL PENETRATIONS 11' - 0" A.F.F. STOREFRONT LOUNGE ENTRY SALES DISPLAY CEILING

CASE ENGINEERING, INC.

3 5/8" METAL FRAMING BY G.C.

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

5/8" TYPE " X" GYP. BOARD 1 5/8" METAL FRAMING BY G.C. 17 A-502

3 1/2" METAL STUD FRAMING SPACED AT 16" O.C.

EXISTING DEMISING WALL BEYOND

3/4" TYPE " X" GYP. BOARD ALIGN

11' - 5" A.F.F.

EXISTING LANDLORD STRUCTURAL BEAM; REF. LANDLORD STRUCTURAL DWGS

T.O. LIGHT COVE

11' - 0" A.F.F. STOREFRONT DISPLAY CEILING

1 5/8"

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C.

10' - 11" A.F.F. T.O. STOREFRONT

5"

3"

1" 1 1/2"

5/8" TYPE " X" GYP. BOARD AT CEILING, TYP.

2"

SECTION DETAIL - DEMISE ABOVE ENTRY

2

SCALE: 1 1/2" = 1'-0"

LEASE LINE

ARAKAWA MERCHANDISING TRACKS MODEL CRB 1800A, RECESSED INTO GWB CEILING, POWDERCOATED TO MATCH ADJ. FINISH PT-01C ; G.C. TO TAPE AND MUD ALL GYP. BOARD EDGES PRIOR TO INSTALLING; G.C. TO ENSURE NEAT INSTALL OF ARAKAWA TRACKS AND PATCH ANY AND ALL ROUGH GYP. EDGES AS REQUIRED

UL263: 1-HR RATED ALT. DEMISING PARTITION

4

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

TRACK LIGHT HEAD; REF. RCP

8' - 2" A.F.F. B.O. ENTRY SOFFIT VIF

3/4" FRT PLYWOOD BLOCKING ABOVE CEILING AT ARAKAWA TRACKS AND LIGHT COVE

5"

OSBORN

EXIST. COMPOSITE METAL PANEL TO REMAIN

HOLD

5"

FRT BLOCKING AS REQ'D

FRT BLOCKING AS REQ'D

ALIGN

TM

5/8" TYPE " X" GYP. BOARD AT LIGHT COVE, TYP. PT-01C

5/8" TYPE 'X' GYP. BOARD

EXISTING LANDLORD STOREFRONT SYSTEM TO REMAIN

STRUCTURAL ENGINEER

3/4" FRT PLYWOOD BLOCKING ABOVE CEILING AT ARAKAWA TRACKS AND LIGHT COVE

EXISTING LANDLORD ENTRY SOFFIT TO REMAIN

ALIGN GYP. W/ TOP OF MULLION

LICENSE # C-4550

6"

6"

4"

8"

3 1/8"

HOLD

HOLD

HOLD

HOLD

VIF

5"

2 1/2"

STOREFRONT LIGHT COVE DETAILS SCALE: 3" = 1'-0"

NEW WOOD VENEER DISPLAY PLATFORM AT INTERIOR DISPLAY WINDOWS BY F.C.. FINISH TO MATCH WD-01

2' - 3 13/16" VIF 2' - 3 1/16" PLATFORM

4

ALIGN

EXISTING 25 MILL MEMBRANE FLASHING, CONTINUOUS INTO ROUGH OPENING 1' - 6" A.F.F. KNEE WALL

STAMP

ALIGN

V.I.F

DEMISING WALL W/ 6" METAL FRAMING BY LANDLORD

EXISTING LANDLORD STOREFRONT SYSTEM TO REMAIN

1' - 5 1/4"

EXISTING LANDLORD ENTRY SOFFIT TO REMAIN

VIF

1' - 6" DISPLAY PLATFORM

2' - 6"

LEASE LINE

3 3/8"

5"

1 1/8"

2"

3 1/8"

1 9/16"

1 9/16"

GYP. BOARD LEDGE BELOW

ALIGN 1 5/8" 3 3/8"

ALIGN

ALIGN EDGE OF PLATFORM WITH EXISTING STOREFRONT BEYOND

3/4" TYPE " X" GYP. BOARD

7/8"

3/4" REVEAL EXISTING STOREFRONT

1 5/8" METAL FRAMING BY G.C. SPACED AT 16" O.C., TYP.

7 1/4"

2 3/16" VIF

A-502

FRT BLOCKING AS REQ'D

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

3 1/8"

RETAIL TENANT

5"

MEP ENGINEER

EXISTING STOREFRONT KNEE WALL 5/8" TYPE "X" GYP. BOARD. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

5/8" TYPE " X" GYP. BOARD EXISTING 1-HR RATED DEMISING WALL

3/4" REVEAL

PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: Author CHECKED BY: Checker 0' - 0" A.F.F. FINISHED FLOOR 3/4" REVEAL PREFINISHED BY F.C. TO MATCH PT-05

AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

CONSTRUCTION DETAILS AT STOREFRONT

3

ENLARGED PLAN - DEMISE ABOVE ENTRY SCALE: 1 1/2" = 1'-0"

1

DISPLAY PLATFORM SECTION SCALE: 3" = 1'-0"

A-502


ARCHITECT

19' - 9" A.F.F.

19' - 9" A.F.F. B.O. EXISTING SLAB UNDERSIDE OF EXISTING SLAB

UNDERSIDE OF EXISTING SLAB BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP

CONTINUOUS METAL TRACK

CONTINUOUS METAL TRACK

CONTINUOUS METAL TRACK

CONTINUOUS METAL TRACK

NEW FINISHED FLOOR AS SCHEDULED

NEW FINISHED FLOOR AS SCHEDULED

NEW FINISHED FLOOR AS SCHEDULED

NEW FINISHED FLOOR AS SCHEDULED

6" METAL STUD, SPACED AT 16" O.C. TYP

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP

NEW FINISHED FLOOR AS SCHEDULED

7 1/4"

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY

0' - 0" A.F.F.

FINISHED FLOOR

FINISHED FLOOR

NOTE: BASE AS SCHEDULED

4 7/8"

NOTE: BASE AS SCHEDULED

4 1/4"

NOTE: BASE AS SCHEDULED

4 7/8"

NOTE: BASE AS SCHEDULED

2 1/2" VERTICAL METAL 'Z' FURRING AT 24" O.C.

PAINT EXTERIOR TO MATCH EXISTING (1) LAYER 5/8" TYPE 'X' GYP. BOARD

NOT USED

2 HR RATED 8" CMU

OWNER'S REPRESENTATIVE

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER

1 1/4" POLYISSOCYANURATE FOAM SHEATHING, R-7.6

CASE ENGINEERING, INC.

NEW FINISHED FLOOR AS SCHEDULED

796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

0' - 0" A.F.F.

NOTE: BASE AS SCHEDULED

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

T.O. EX'G LANDLORD DOOR

T.O. PARTIAL HEIGHT WALL

0' - 0" A.F.F.

4 1/4"

7' 2" V.I.F

9' - 0" A.F.F.

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE; EXTEND GYP. BOARD TO DECK ABOVE AT LOCATION'S WITH NO CEILING, TYP.; REF. RCP

CONTINUOUS METAL TRACK

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD AT TOP; FINISH TO MATCH ADJ. WALL FINISH PT-01C

. 6"

6" .

6"

BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES

EXISTING LANDLORD CMU WALL ALIGN

B.O. EXISTING SLAB UNDERSIDE OF EXISTING SLAB

LICENSE # C-4550

FINISHED FLOOR STRUCTURAL ENGINEER

NOTE: BASE AS SCHEDULED

10 3/4"

TM

OSBORN ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS. G.C TO PROVIDE 3 5/8" 20 GAUGE METAL STUD IN LIEU OF 6" METAL STUD PROVIDE WALL BASE AS SCHEDULED REF. A-104 FINISH PLAN

C

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN

PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN

D

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS EXTEND GYP. BOARD 6" ABOVE CEILING

E

WALL TYPE "E" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT • •

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

F

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD PROVIDE GYP. BOARD AT TOP OF PARTIAL HEIGHT PARTITION AND FINISH TOP OF PARTITION TO MATCH WALL FINISH USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS

WALL TYPE "F" - INTERIOR NON-LOAD BEARING PARTITION - CMU INFILL

REFERENCE UL-U905 • •

2 HOUR RATED 8" CMU WALL WITH 'Z' FURRING ON INTERIOR SIDE, REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD AT ONE SIDE ONLY; INSTALL GYP. BOARD AT TENANT SIDE ONLY AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN

PROVIDE WALL BASE AS SCHEDULED REF. A-104 FINISH PLAN

PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN

PARTITION TYPES SCALE: 1 1/2" = 1'-0"

3/8"

3/4" 3/8" REF. A-100 FOR PARTITION TYPE

BOH

2"

SCRIBE

7/8"

EXISTING CONCRETE FLOOR WITH NEW POLISHED FINISH AS SCHEDULED; REF. A-104 C-04

B-01

PAINTED WOOD TRIM FOR DOOR CASING BY F.C. REFER TO DOOR HEAD AND JAMB DETAILS A-601

TRIM PROFILES

2

SCALE: 6" = 1'-0"

1/4"

EXISTING SLOPED SIDEWALK

SLOPE 1:48 MAX.

EXISTING CONCRETE FLOOR TO REMAIN, G.C TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR; REF. A-104 C-02

EXISTING CONCRETE SLAB ON GRADE, G.C. TO ENSURE LEVEL SURFACE FOR APPLICATION OF NEW FLOOR FINISH

REF. A-100 FOR PARTITION TYPE

PROJECT NO.: 218259

PAINTED WOOD BASE SCRIBE BASE TO FLOOR B-01 PT-01B

DATE: 02/27/2019 DRAWN BY: RA, NK

3/4" SALES

CHECKED BY: JSP AREA: 1,400 SF

# EXISTING CONCRETE FLOOR TO REMAIN, G.C TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR; REF. A-104 C-02

1

B-01 WALL BASE 01 SCALE: 3" = 1'-0"

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

4"

LEASE LINE

SCALE: 3" = 1'-0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

1"

NEW REMOVABLE 3/8" THICK WALKOFF MAT BY RETAIL TENANT' G.C. CPT-02

THRESHOLD 'A'

SCALE: 3" = 1'-0"

5"

EXISTING ENTRY DOOR

G.C. TO CONFIRM EXISTING THRESHOLD IS ADA COMPLIANT AND REPLACE IF REQ'D W/ PEMKO ADA COMPLIANT THRESHOLD

B-02 WALL BASE 02

INTERIOR (PUSH SIDE)

EXTERIOR (PULL SIDE)

3

STAMP

TR-01

PAINTED WOOD TRIM FOR WALL BASE BY G.C.

4

4"

3 5/8"

4"

4" TALL RUBBER WALL BASE, SCARIFY SURFACE BEHIND BASE ONLY PRIOR TO INSTALLATION B-02

1"

5

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK

WALL TYPE "D" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS

WALL TYPE "C" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT

RETAIL TENANT

B

WALL TYPE "B" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT

5"

A

WALL TYPE "A" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT

PARTITION, TRIM, & THRESHOLD DETAILS

A-600


ARCHITECT

6" METAL FRAMING

2" 1/4"

3 5/8" DOUBLE METAL STUD LINTEL

3' - 0"

1/8"

DOOR

2"

15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671

7' - 0"

MEP ENGINEER

CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730

5' - 0"

LICENSE # C-4550

3' - 0"

G.C. TO PROVIDE MIRROR; CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC GL-02

STRUCTURAL ENGINEER

5/8"

3/8"

DOOR 7' - 0 3/4"

PT-01E

7' - 7 1/2"

DOOR

7' - 7 1/8"

PT-01E

6' - 10 1/8"

OWNER'S REPRESENTATIVE

1/8"

4 1/2"

1/16"

3' - 0"

MIRROR V.I.F.

EQ

3"

EQ

11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net

2" PAINTED HOLLOW METAL DOOR FRAME PT-01E

1/4"

2"

1/8"

2"

GL-02

DEADLOCK BY F.C.; THUMBTURN AT BOH SIDE

3"

3' - 0 1/4"

9"

4 1/2"

5/8"

WD-01

SALES (PUSH)

KICK PLATE, AT PULL SIDE ONLY REF. DOOR HARDWARE SCHEDULE

1/16"

1/4" 2"

2" 1/8"

1/4"

B.O.H./RESTROOM (PULL)

SALES (PULL)

2" ADA RESTROOM SIGNAGE, G.C. TO INSTALL PER LOCAL CODE REQUIREMENTS

MIRROR VIF

SHIM AS REQ'D

HOLLOW METAL DOOR ; PT-01E

3/8"

KICK PLATE, BY F.C. REF. DOOR HARDWARE SCHEDULE

1/4" MIRROR, BY G.C. GL-02

1/16"

2' - 2 7/8"

3' - 0"

4 1/2"

B.O.H. (PUSH)

7'-7 3/4" DOOR OPENING

1/4"

WOOD VENEER W/ MDF CORE DOOR, BY F.C. WD-01

1/16" 1/16" MAX. MAX. 7' - 7 1/8" DOOR

1 1/4" 1 7/8"

4 1/2"

4 1/8"

7/8" x 2" PAINTED WOOD TRIM BY F.C. TR-01 PT-01B

4 1/2"

2' - 3"

1/16"

MOUNT CLOSER AT RESTROOM SIDE, W/ HOLD OPEN

1/4"

3 5/8" METAL TRACKS

HOLLOW METAL DOOR FRAME PT-01E

1"

1/2" x 1 1/4" PAINTED WOOD DOOR STOP, BY F.C. PT-01B

4 1/2"

3 5/8" DOUBLE METAL STUD LINTEL

2"

7/8"

3' - 0"

6' - 10"

7/8" X 2" PAINTED WOOD TRIM, BY F.C. PT-01B TR-01

1/4" 2"

DOOR

3 5/8" METAL FRAMING

5/8"

PAINTED WOOD DOOR FRAME, BY F.C. PT-01B

1/2"

1/4"

G.C. TO SHIM AS REQ'D

6" METAL TRACKS

3' - 0 1/2"

TM

BOH (PUSH)

OSBORN

WD-01

NEW DUMMY LEVERS BOTH SIDES OF DOOR

NEW KICK PLATE AT PUSH SIDE ONLY

NEW KICK PLATE AT PUSH SIDE ONLY

SALES (PULL)

SALES (PUSH)

NEW PRIVACY LEVERSET, PUSH BUTTON AT RESTROOM SIDE

DOOR TYPE "D"

DOOR TYPE "C" SECTION DETAIL

1/2" 1"

5/8" TYPE 'X' GYP. BOARD

VERIFY WITH F.C. SHOP DWGS. 1/2"

1/2"

1/2" 1"

WALL BASE AS SCHEDULED BELOW, BY G.C.

DOUBLE 20 GA. METAL STUDS @ JAMB

PT-01B

EXISTING LOCKSET LEVER HANDLE

3" WHITE VINYL RETAIL TENANT LOGO; SIGNAGE FILED UNDER SEPARATE PERMIT

3' - 0"

ALIGN

7/8"

WALL BASE AS SCHEDULED BELOW B-01 PT-01B

7/8" x 2" PAINTED WOOD TRIM BY F.C. PT-01B TR-01

EQ

EQ 4 1/2"

NEW DUMMY LEVER, BY F.C.; SEE DOOR HARDWARE SCHEDULE

2" 1/4"

1/16" MAX

1/16" MAX

SPRING HINGE, BY F.C.; REF. DOOR HARDWARE SCHEDULE

4 1/2"

3' - 0" DOOR 1/4"

SALES (PULL)

2" 1/4"

9"

5/8" TYPE 'X' GYP. BOARD

FUTURE SIGN

EXISTING EXIT DEVICE

V.I.F.

7 1/4" 1 1/4"

1 7/8"

BLOCKING AS REQ'D, BY G.C.

EXISTING STOREFRONT DOORS AND HARDWARE TO REMAIN U.N.O.

EXISTING DOOR AND HARDWARE TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION AND CONSTRUCTION, CLEAN AND PAINT; FINISH TO MATCH PT-01B

4 1/8"

PAINTED WOOD DOOR FRAME, BY F.C. PT-01B

V.I.F.

1/2" x 1 1/4" PAINTED WOOD DOOR STOP, BY F.C. PT-01B

V.I.F.

EXISTING HOLLOW METAL DOOR FRAME PT-01B

5' - 0"

7/8" x 2" PAINTED WOOD TRIM, BY F.C. PT-01B TR-01

3' - 0" DOOR

EXIT CORRIDOR (PULL)

MIRROR AT DOOR, BY G.C. GL-02

1/4"

2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203

3'-3" ROUGH OPENING

6' - 0"

EXISTING CLOSER

VENEER WOOD W/ MDF CORE DOOR BY F.C., REF. DOOR SCHEDULE WD-01

B.O.H. (PUSH)

RETAIL TENANT

SCALE: 3" = 1'-0"

V.I.F.

4

SCALE: 3" = 1'-0"

RESTROOM (PULL)

DOOR TYPE "C"

8' - 0"

DOOR TYPE " D" SECTION DETAIL

7' - 0" DOOR

5

ENGINEERING

990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com

NEW 7-PIN SMALL FORMAT INTERCHANGEABLE CORE 'BEST' LOCKS

BOH (PUSH) DOOR TYPE "B"

DOOR TYPE "A"

STAMP

3

DOOR TYPE " D" PLAN DETAIL - MIRROR DOOR

1

SCALE: 3" = 1'-0"

DOOR TYPES SCALE: 1/2" = 1'-0"

DOOR SCHEDULE

DOOR

TENANT'S G.C. TO CHAMFER CORNER @ 45 ANGLE AT BOTH SIDES OF DOOR AND PAINT ALL VISIBLE SURFACES PT-01B WALL BASE AS SCHEDULED BELOW BY TENANT'S G.C. B-01 PT-01B

VESTIBULE (PUSH)

45°

2"

5/8"

5/8"

2"

45°

5/8" TYPE 'X' GYP. BOARD

4 7/8"

BLOCKING AS REQ'D DOUBLE 20 GA. METAL STUDS @ JAMB

WALL BASE AS SCHEDULED BELOW BY LANDLORD'S G.C. B-01 PT-01E

5/8" TYPE 'X' GYP. BOARD. (TO BE WATER-RESISTANT AT WET WALLS)

TENANT'S G.C. TO CHAMFER CORNER @ 45 ANGLE AT BOTH SIDES OF DOOR AND PAINT ALL VISIBLE SURFACES PT-01E

HINGE; REF. DOOR HARDWARE SCHEDULE

2

2"

3'-0" DOOR 1/8"

DOOR TYPE C" PLAN DETAIL SCALE: 3" = 1'-0"

ADA RESTROOM (PULL)

2" 1/8"

HOLLOW METAL DOOR; REF. DOOR SCHEDULE

FRAME

DOOR TYPE

DOOR NO.

DESCRIPTION

MATERIAL

FINISH

HARDWARE SET

WIDTH

SIZE HEIGHT

THK

A

EX-01 EX-01

STOREFRONT ENTRY DOOR

METAL / GLASS

EXG

1

2' - 11 3/4"

9' - 0"

1 3/4"

B

EX-02 EX-02

BOH EXIT DOOR

EX'G

PT-01B TENANT SIDE

2

3' - 0"

7' - 0"

1 3/4"

C

EX-03 EX-03

DOOR TO RESTROOM

HOLLOW METAL

PT-01E

3

3' - 0"

7' - 0"

1 3/4"

4 7/8"

2 / A-601

D

04 04

DOOR TO BOH

WOOD / MIRROR

WD-01/GL-02

4

3' - 0"

7' - 7 1/8"

1 3/4"

7 1/4"

3/A-601

HOLLOW METAL DOOR FRAME

LEVERSET, REF. DOOR HARDWARE SCHEDULE

*SEE DOOR SWING DIRECTION ON CONSTRUCTION PLAN, TYP.

THROAT DIM.

JAMB DETAIL

HEAD DETAIL

THRESHO MATERIAL LD DETAIL

VIF

-

-

3/A-600

EX'G

EX'G

10 3/4"

-

-

--

EX'G

PT-01B TENANT SIDE

4 / A-601

--

HOLLOW METAL

PT-01E

--

5/A-601

--

WOOD

PT-01B

--

FINISH

F.R.

SIGNAGE

NOTES (*F/I = FURNISH & INSTALL)

G.C. TO PROVIDE WHITE 1"H VINYL LETTERS STATING EXISTING STOREFRONT ENTRY DOOR AND HARDWARE TO REMAIN; G.C. TO 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS PROVIDE NEW 7-PIN SFIC 'BEST' LOCK AND 6 SETS OF KEYS HOURS' AT THE EGRESS SIDE DOOR HEADER EXISTING BOH EXIT DOOR AND HARDWARE TO REMAIN; G.C. TO PROVIDE NEW 7-PIN SFIC 'BEST' LOCK AND 6 SETS OF KEYS 45 MINS VIF ---

LL'S G.C. TO PROVIDE BLACK RESTROOM SIGNAGE WITH WHITE LETTERS AS PER LOCAL CODE REQUIREMENTS

F/I BY LL'S G.C.; TENANT G.C. TO REPLACE HINGES AND LEVERSET WITH BLACK HARDWARE. REF. HARDWARE SCHEDULE DOOR, FRAME, AND HARDWARE FURNISHED BY F.C. U.N.O. AND INSTALLED BY G.C. SILENCERS AND MIRROR BY G.C. REF. HARDWARE SCHEDULE

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218259 DATE: 02/27/2019

DOOR HARDWARE SCHEDULE

DRAWN BY: Author

SET #1 - STOREFRONT ENTRY DOORS - EXISTING

SET #2 - BOH EXIT - EXISTING TO REMAIN

SET #3 - DOOR TO RESTROOM

SET #4 - MIRROR DOOR

NOTE: EXISTING HARDWARE TO REMAIN; G.C. TO CONFIRM EXISTING LOCK IS SFIC AND PROVIDE NEW 'BEST' LOCK CORE OR APPROVED EQUAL 7-PIN SMALL FORMAT INTERCHANGEABLE CORE AND 6 SETS OF KEYS; IF EXISTING LOCK IS NOT SFIC; G.C. TO REPLACE LOCK AND CORE PER ABOVE FINISH: COLOR TO MATCH ADJ

NOTE: EXISTING HARDWARE TO REMAIN; G.C. TO CONFIRM EXISTING LOCK IS SFIC AND PROVIDE NEW 'BEST' LOCK CORE OR APPROVED EQUAL 7-PIN SMALL FORMAT INTERCHANGEABLE CORE AND 6 SETS OF KEYS; IF EXISTING LOCK IS NOT SFIC; G.C. TO REPLACE LOCK AND CORE PER ABOVE FINISH: COLOR TO MATCH ADJ

EXISTING HARDWARE TO BE REPLACED, SEE BELOW.

LEVERS (BY F.C.): (2) SCHLAGE F170 LAT 622, LATITUDE DUMMY LEVER; FINISH: 622 MATTE BLACK

LEVERSET: (1 SET) SCHLAGE F40 LAT 622, LATITUDE (PRIVACY) LEVERSET; FINISH: 622 MATTE BLACK

DEADLOCK (BY F.C.): (1 SET) SCHLAGE B560B, DEADLOCK LESS SFIC WITH ADA COMPLIANT THUMBTURN; FINISH: 622 CUSTOM MATTE BLACK

DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: BLACK 693

CYLINDER - MORTISE FOR DEADLOCK (BY G.C.): (1) 'BEST' LOCK 1E-74-C181-RP2, G.C. TO PROVIDE 7-PIN SMALL FORMAT INTERCHANGEABLE CORE MORTISE CYLINDER IF USING APPROVED EQUAL; G.C. TO PROVIDE 6 SETS OF KEYS;FINISH: POWDER COATED TO MATCH MT-02

HINGES: (3 PAIR) EMTEK 92015 4 1/2"x4 1/2"; FINISH: BLACK US19

HINGES (BY F.C.) : (3 PAIR) EMTEK 4" x 4" BUTT SPRING HINGE; 95014; FINISH: MATTE BLACK; US19

KICK PLATE: (1) IVES 8400 - 10"X34"; NMH-A; FINISH: BLACK PLASTIC

KICK PLATE (BY F.C.): (1) IVES 8400 - 10"X34"; NMH-A; FINISH: BLACK PLASTIC

WALL STOP: (1) IDH 'CUP' STOP 13018; FINISH: 019 MATTE BLACK

WALL STOP (BY F.C): (1) IVES WS65; FINISH: ALUMINUM: US27

SILENCERS (BY G.C.): (3) IVES SR66; FINISH WHITE

SILENCERS (BY G.C.): (3) IVES SR66; FINISH WHITE

NOTE: KICK PLATE TO BE INSTALLED ON PUSH SIDE ONLY; INSTALL WALL STOP ON RESTROOM SIDE.

NOTE: KICK PLATE TO BE INSTALLED ON BOH SIDE ONLY; INSTALL WALL STOP ON BOH SIDE. G.C. TO PROVIDE SILENCERS AND G.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO DOOR

CHECKED BY: Checker AREA: 1,400 SF

#

ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION

DATE 02/27/2019 03/04/2019

DOOR & HARDWARE SCHEDULE & DETAILS

A-601




TENANT

ARCHITECT OF RECORD:

DRAWING LIST

ABBREVIATIONS

ISSUE

LANDLORD'S REPRESENTATIVE

CONTACTS: JACKIE RENTON ATLAS CAPTIAL GROUP,LLC 450 PARK AVENUE, 4TH FLOOR NEW YORK, NY 10022 EMAIL: JRENTON@ATLAS-CAP.COM M: 212-554-2227

ARCHITECT OF RECORD

O'NEIL LANGAN ARCHITECTS 15 W 37TH ST, 15TH FL NEW YORK, NY 10018

CONTACT: STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 F: 212-279-2671 JENNIFER PALMA JENNIFER@OLARCH.COM

MEP ENGINEER

FISKAA FISKAA ENGINERRING 589 EIGHTH AVENUE NEW YORK NEW YORK 10018

CONTACT: MICHAEL SZABO EMAIL: MSZABO@FISKAA.COM P: 646-940-8717 X 8717

STRUCTURAL ENGINEER

N/A

OWNER'S REPRESENTATIVE

O'NEIL LANGAN 15 WEST 37TH STREET 15TH FLOOR NEW YORK, NY 10018

CONTACT: STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 x 231

42 CROSBY STREET SUITE 1B NEW YORK, NY 10012 AREA OF WORK TENANT SPACE SUIT 1B (1807 SQFT)

42 CROSBY STREET, SUITE 116, NEW YORK, NT 10012

TOM ENNIS ASSOCIATES 33 BOND STREET-LOWER LEVEL NEW YORK, NY 10012

CONTACT: TOM ENNIS EMAIL: ENNIS.TOM@GMAIL.COM M: 917-921 6112

NORTH

2

AREA PLAN

1

SCALE: N.T.S.

--

SITE PLAN SCALE: 1" = 100'-0"

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

SHEET TITLE ARCHITECTURAL COVER SHEET ACCESSIBILITY COMPLANCE RESPONSIBILITY SCHEDULE EGRESS AND ACCESSIBILITY PLAN DEMOLITION PLAN DEMOLITION REFLECTED CEILING PLAN DEMOLITION POWER AND SIGNAL PLAN CONSTRUCTION PLAN FIXTURE PLAN REFLECTED CEILING PLAN POWER AND SIGNAL PLAN FLOOR AND WALL FINISH PLAN SLAB LEVEL PLAN BUILDING SECTIONS BUILDING SECTIONS INTERIOR ELEVATIONS - SALES SHOP INTERIOR ELEVATIONS - LOUNGE SHOP INTERIOR ELEVATIONS - FR AND FR LOUNGE

A-305.00

INTERIOR ELEVATIONS - VESTIBULE, STORAGE ROOM AND ADA FR

A-306.00 A-307.00

INTERIOR ELEVATIONS - BOH ENLARGED ADA RESTROOM PLAN AND ELEVATIONS

A-500.00 A-501.00 A-502.00 A-600.00 A-601.00 A-602.00 EN-100.00

CEILING CONSTRUCTION DETAILS CONSTRUCTION AND CEILING DETAILS CONSTRUCTION AND CEILING DETAILS PARTITION, TRIM, AND THRESHOLD DETAILS DOOR AND HARDWARE SCHEDULE DOOR AND THRESHOLD DETAILS ENERGY CODE ENERGY CODE COMPLIANCE FORMS

M-100.00 M-101.00 M-102.00 M-300.00 M-700.00 M-701.00

MECHANICAL H.V.A.C. TITLE SHEET H.V.A.C. SPECIFICATIONS SHEET 1 OF 2 H.V.A.C. SPECIFICATIONS SHEET 2 OF 2 H.V.A.C. PLANS AND SCHEDULES H.V.A.C. DETAILS SHEET 1 OF 2 H.V.A.C. DETAILS SHEET 2 OF 2

BUILDING CODE ANALYSIS & CODE NOTES 1. SCOPE OF WORK: THIS IS A PERMIT APPLICATION FOR INTERIOR IMPROVEMENTS FOR A NEW RETAIL STORE. THE PROJECT INCLUDES WORK ON THE GROUND FLOOR OF AN EXISTING BUILDING. WORK INCLUDES ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, SPRINKLER, AND FIRE ALARM WORK. NO CHANGE TO EXISTING USE, EGRESS, OR OCCUPANCY. 2. GOVERNING CODES: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO THE REQUIREMENTS OF THE FOLLOWING (INCLUDING AMENDMENTS), AND ANY OTHER FEDERAL, STATE AND LOCAL CODES, LAWS AND ORDINANCES THAT APPLY: - 2014 NEW YORK CITY BUILDING CODE - 2014 NEW YORK CITY ENERGY CONSERVATION CODE - 2014 NEW YORK CITY MECHANICAL CODE - 2014 NEW YORK CITY PLUMBING CODE - 2014 NYBC CHAPTER 11 AND INTERNATIONAL CODE COUNCIL- ACCESSIBLE AND USABLE BUILDING AND FACILITIES (A117.1) - NYC BUREAU OF ELECTRICAL CONTROL (BEC) 3. CONSTRUCTION SERVICE CENTER NEW YORK CITY DEPARTMENT OF BUILDINGS 280 BROADWAY, NEW YORK, NY 10007 4. CONSTRUCTION TYPE: TYPE : 1B FULLY SPRINKLERED NUMBER OF STORIES: 7

A. EXISTING DEMISING PARTITIONS: 1-HR FIRE RATED PARTITION TO CONFORM TO USG TEST NO. 1174-OSU WITH 5/8" TYPE "X" FIRECODE CORE BOTH SIDES OF 3 5/8" 20 GAUGE METAL STUDS. FRAMING AND GYP. BD TO EXTEND TO BOTTOM OF METAL DECK ABOVE. FIRE-RATED ACOUSTICAL CAULKING TO SEAL ALL GAPS AT TOP AND BOTTOM OF PARTITION. G.C. TO PATCH AND RE-SEAL AS REQUIRED TO RESTORE THE DEMISING PARTITIONS TO THEIR ORIGINAL FIRE PROTECTION RATING. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. B. ALL PENETRATIONS (INCLUDING FOR PIPES AND CONDUITS) THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH UL LISTED THROUGH PENETRATION FIRESTOP SYSTEMS AND FIRE-RATED SEALANT WITH RATINGS EQUAL TO THAT OF THE RATED ASSEMBLIES THROUGH WHICH THEY PASS. C. COLUMNS, GIRDERS, BEAMS, JOISTS, DECKS AND SLABS ALL ARE PART OF LANDLORD ASSEMBLY AND HAVE EXISTING FIRE PROTECTION WHICH SHOULD REMAIN. WHERE SUCH FIRE PROTECTION IS DAMAGED, IT SHALL BE RESTORED TO ITS ORIGINAL CONDITIONS AND FIRE PROTECTION RATING. TENANT CEILING (NON-COMBUSTIBLE) DOES NOT FORM A PART OF THE LANDLORD RATED ROOF ASSEMBLY. D. ALL CEILING AND WALL MATERIALS MUST BE CLASS 'A'; INTERIOR FINISHES TO BE CLASS C OR GREATER. DOES NOT APPLY TO TRIM DEFINED AS BASEBOARDS AND MOLDINGS, OR TO MATERIALS LESS THAN 1/28 INCH IN THICKNESS APPLIED DIRECTLY TO SURFACE OF WALLS OR CEILINGS.

BASED ON FIRE SEPARATION DISTANCE (PER 2014 NYCBC, TABLE 602) EXTERIOR WALLS:

5. OCCUPANT GROUP: GROUP "M" (MERCANTILE)

7. OCCUPANT LOAD: (PER 2014 NYCBC: CHAPTER 10, TABLE 1015.1) FLOOR AREA: SALES: 1354 SQ FT / 60 = STOCK: 396 SQ FT / 300 = RESTROOM: 57 SQ FT/ 300= NUMBER OF OCCUPANTS: TOTAL:

11. FIRE RATED ASSEMBLIES:

12. FIRE RESISTANCE RATING REQUIREMENT (PER 2014 NYCBC, TABLE 601) BUILDING ELEMENTS: STRUCTURAL FRAME (COLUMNS, ETC): BEARING WALLS (EXTERIOR): NON BEARING WALLS (EXTERIOR): NON BEARING (INTERIOR): FLOOR CONSTRUCTION ( INCL. SUPPORTS):

23 OCCUPANTS 2 OCCUPANTS 1 OCCUPANT 26 PERSONS

8. EXITS REQUIRED: OCCUPANT LOAD < 50 REQUIRES MINIMUM OF 1 EXIT (PER 2014 NYCBC: SECTION 1006.2) NUMBER OF EXITS REQUIRED BY OCCUPANT LOAD: 1 NUMBER OF EXITS PROVIDED: 1 MAXIMUM TRAVEL DISTANCE TO EXIT: 75 FT (PER 2014 NYCBC: SECTION 1021.2) ACTUAL TRAVEL DISTANCES (REF. G-003 EGRESS PLAN): ROUTE 1: 38'-0" ROUTE 2: 51'-9" ROUTE 3: 67'-8" EGRESS WIDTH PER OCCUPANT SERVED: (0.2) x 28 PERSONS = 5.6 IN 9. EXITS PROVIDED AND DATA: ONE (1) EXIT AT STOREFRONT @ 6'-0" (2 LEAVES X 3'-0") CLEAR WIDTH

--

T-000.00 G-001.00 G-002.00 G-003.00 D-100.00 D-101.00 D-102.00 A-100.00 A-101.00 A-102.00 A-103.00 A-104.00 A-105.00 A-300.00 A-301.00 A-302.00 A-303.00 A-304.00

6. TENANT LEASE AREA: 1807 SQ.FT.

EXPEDITOR

SHEET

MEP ENGINEER:

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

DAN KLACIK EMAIL: DKLACIK@BONOBOS.COM M: 908-801-0655

ISSUE FOR PERMIT

CONTACTS: ELIZABETH COOKSEY EMAIL: E.COOKSEY@MODCLOTH.COM M: 214-207-0672

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

09/07/2018

MODCLOTH 45 W 25TH STREET FLOOR 2 NEW YORK, NY 10010

ADJ. ADJACENT A.F.F ABOVE FINISHED FLOOR A.C.T. ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES BLK. BLOCKING CL CENTERLINE CLR. CLEAR CLG. CEILING CNTR. COUNTER CNT. CENTER CONC. CONCRETE COL COLUMN C.O.W CENTER OF WALL CPT. CARPET CONT. CONTINUOUS CONSTR. CONSTRUCTION C.G. CORNER GUARD CMU CONCRETE MASONRY UNIT DEMO DEMOLITION DWG. DRAWING DIA. DIAMETER DN. DOWN DR. DOOR ELEC. ELECTRICAL E.P. ELECTRICAL PANEL EMER. EMERGENCY EQ. EQUAL (E) EXISTING EA. EACH EXT. EXTERIOR FBO. FURNISHED BY OWNER F.C. FIXTURE CONTRACTOR F.F. FINISH FLOOR F.D. FLOOR DRAIN FR FRAME F.R.T FIRE RETARDANT TREATED F.S. FIRE EXTINGUISHER FURN. FURNISH F.O.W. FACE OF WALL GA. GAUGE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GWB. GYPSUM WALL BOARD HC HOLLOW CORE H.M. HOLLOW METAL HGT. HEIGHT HORIZ. HORIZONTAL IN INCH INST. INSTALL INSUL INSULATION KE KITCHEN EQUIPMENT L.O.D. LEASE OUTLINE DRAWING L.N. LANDLORD MAX MAXIMUM MAT'L. MATERIAL M.D.F. MAIN DISTRIBUTION FACILITY MECH. MECHANICAL MFR. MANUFACTURER MIR. MIRROR MIN. MINIMUM M.R. MOISTURE RESISTANT M.O. MASONRY OPENING N/A NOT APPLICABLE (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPG. OPENING OPP. OPPOSITE PT. PAINT PLWD. PLYWOOD P-LAM. PLASTIC LAMINATE PNL. PANEL QTY. QUANTITY RCP REFLECTED CEILING PLAN RB. RUBBER BASE REINF. REINFORCING REQ'D. REQUIRED REV. REVISED/REVISION R.R. RESTROOM SC SOLID CORE SCHED. SCHEDULE SF. SQUARE FOOT SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE SUSP. SUSPENDED TEMP. TEMPERED TBD TO BE DETERMINED TBV TO BE VERIFIED TYP. TYPICAL UON UNLESS OTHERWISE NOTED V.C.T. VINYL COMPOSITE TILE V.I.F VERIFIED IN FIELD VERT. VERTICAL WD WOOD

A. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. B. A CLEAR AISLE BETWEEN EXITS OF 36" SHALL BE MAINTAINED FREE OF FIXTURES, MERCHANDISE AND OTHER OBSTRUCTIONS. C. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED AND SHALL CONFORM TO 2014 NYCBC.

2 HR 2 HR 1HR 0 HR 2 HR

10≤X< 30 : 1 HR

13. LIFE SAFETY SYSTEMS: A. FIRE SPRINKLER SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. SPRINKLER CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ON-SITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. B. FIRE ALARM SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. FIRE ALARM CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ON-SITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. C. EMERGENCY LIGHTING - NEW, PROVIDED BY TENANT

HANDICAP ACCESSIBILITY: 11. A. AN ACCESSIBLE ROUTE IS EXISTING FROM THE EXTERIOR TO THIS TENANTS SPACE. SEE ORIGINAL LANDLORD SITE AND BUILDING PLANS ON FILE. B. THIS TENANT SPACE IS FULLY ACCESSIBLE TO ALL AREAS OCCUPIED BY THE PUBLIC, ACCESSIBLE EMPLOYEE WORK AREAS HAVE BEEN PROVIDED. C. WHERE INDICATED PROVIDE INDUSTRY STANDARD ADA APPROVED SIGNAGE, PROPOERLY ADDRESSING RAISED AND BRAILLE CHARACTERS, PICTOGRAMS, FINISH AND CONTRAST, CHARACTER PROPORTION AND HEIGHT, AND MOUNTING HEIGHT. 12. SANITARY FACILITIES: (PER 2014 NYCBC TABLE 2909.1) (1) UNISEX RESTROOM, FULLY ACCESSIBLE TO CUSTOMERS AND EMPLOYEES TO BE PROVIDED. 13. DRINKING FOUNTAIN: (PER 2015 IPC TABLE 2909.1) (1) DRINKING FOUNTAIN THAT COMPLIES WITH THE REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR & (1) DRINKING FOUNTAIN THAT COMPLIES WITH THE REQUIREMENTS FOR STANDING PERSONS TO BE PROVIDED. OR (1) WATER DISPENSING STATION THAT COMPLIES WITH THE REQUIREPMENTS FOR PEOPLE WHO USE A WHEELCHAIR AND STANDING PERSON TO BE PROVIDED IN LIEU OF A DRINKING FOUNTAIN. 14. SERVICE SINK: (PER 2015 IPC TABLE 2909.1) (1) SERVICE SINK TO BE PROVIDED.

E-100.00 E-101.00 E-102.00 E-300.00 E-400.00 E-500.00

ELECTRICAL ELECTRICAL TITLE SHEET ELECTRICAL SPECIFICATIONS (1 OF 2) ELECTRICAL SPECIFICATIONS (2 OF 2) ELECTRICAL POWER PLAN ELECTRICAL LIGHTING PLAN ELECTRICAL, POWER RISER DIAGRAM PANEL SCHEDULE AND DETAIL

FA-100.00 FA-300.00

FIRE PROTECTION FIRE ALARM TITLE SHEET FIRE ALARM FLOOR PLAN

P-100.00 P-101.00 P-300.00 P-700.00

PLUMBING PLUMBING NOTES, LISTS AND SCHEDULES PLUMBING SPECIFICATIONS PLUMBING PLAN AND RISER DIAGRAMS PLUMBING DETAILS

SP-100.00 SP-101.00 SP-102.00 SP-300.00 SP-500.00 SP-700.00

SPRINKLER DRAWINGS SPRINKLER NOTES, LISTS AND SCHEDULE SPRINKLER SPECIFICATIONS SHEET 1 OF 2 SPRINKLER SPECIFICATIONS SHEET 2 OF 2 SPRINKLER PLAN SPRINKLER RISER DIAGRAM SPRINKLER DETAILS

REQUIRED SPECIAL INSPECTIONS:

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231

SPECIAL INSPECTIONS :

14. FLAME SPREAD RATINGS FOR INTERIOR FINISHES: FLAME SPREAD RATINGS FOR INTERIOR FINISHES SHALL COMPLY WITH 2014 NYCBC, TABLE 803.3 BUT IN NO CASE SHALL EXCEED CLASS C, MAX FLAME SPREAD INDEX OF 225; MAX SMOKE-DEVELOPED INDEX OF 450

-MECHANICAL SYSTEM -SPRINKLER SYSTEM -FIRE-RESISTANT PENETRATIONS AND JOINTS

15. FIRE EXTINGUISHERS: (PER 2014 IFC, TABLE 906.1, TABLE 906.3(1)) A. ONE FIRE EXTINGUISHER SHALL BE PROVIDED AT ONE PER 3,000 SF; COVERAGE NOT TO EXCEED 75 FEET IN ANY DIRECTION. TENANT SHALL HAVE AT LEAST ONE IN THE STOCK ROOM AREA. B. PROVISIONS AND INSTALLATION IN THE QUANTITY, TYPE AND LOCATIONS REQUIRED BY THE FIRE MARSHALL SHALL PREVAIL.

ENERGY CODE PROGRESS INSPECTION: -HVAC AND SERVICE WATER HEATING EQUIPMENT -HAVC AN SERVICE WATER HEATING SYSTEM CONTROLS -HVAC INSULATION AND SEALING -MAINTENANCE INFORMATION -LIGHTNING CONTROL

16. HAZARDOUS MATERIALS: TESTING, REMOVAL, AND/OR ENCAPSULATION ARE NOT PART OF THIS CONTRACT. IT IS NOT SUSPECTED ANY HAZARDOUS MATERIALS WILL BE FOUND. IF THE PRESENCE OF HAZARDOUS MATERIAL IS SUSPECTED OR DISCOVERED, NOTIFY THE BUILDING OWNER AND MODCLOTH IMMEDIATELY.

STAMP HERE:

BC 1704.16 BC 1704.23 BC 1704.27

DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

FINAL INSPECTION:

COVER SHEET

T-000.00 SHEET 1 OF 27


RESPONSIBILITY SCHEDULE DESCRIPTION

SIGNAGE

SECURITY

TBD

ADT BUSINESS ED KEISER 111 WINDSOR DR. OAK BROOK,IL 60523 PH: 630-788-7858 EKEISER@ADT.COM

LIGHTING

CAPITAL LIGHT ANGELA McCOY 270 LOCUST STREET HARTFORD, CT 06141 PH: 860-520-2387 C: 860-729-2717 ANGELA.MCCOY@CAPITALLIGHT.COM FIXTURE CONTRACTOR

ICON DESIGN KEN BERGMANN 230 SOUTH BEMISTON ST LOUIS, MO 63105 P: 314-725-5721 x109 C: 314 295-9663 KENB@ICONFIXTURES.COM DRAPERY FABRIC

BRAD JOBE BESPOKE FURNITURE BRAD JOBE 231 W 29TH ST SUITE 300 NEW YORK, NY 10001 PH: 212-216-9259 BRAD@BRADJOBE.COM FLOORING

UNCONVENTIONAL FLOORING JASON VALENTA PH: 317-281-8223 VALENTAJASON@HOTMAIL.COM

01.

AUDIO SYSTEM

PLAY NETWORK AUDIO JEFF ROMAN C: 425-629-2760 JROMAN@PLAYNETWORK.COM

SHOPPER TRAK

RETAIL NEXT EDWARD SCHLODDER OFFICE ON THE BEACH 3 LAGOON BEACH DRIVE MILNERTON, SOUTH AFRICA 7441 P: (408) 740-5340 Ext 1035 EDWARD.SCHLODDER@RETAILNEXT.NET

02.

N/A

EXISTING

1. PERMITS AND FEES

G.C.

G.C.

2. INSPECTION / COORDINATION

G.C.

G.C.

3. SPECIAL INSPECTIONS

OWN

OWN

4. TEMPORARY HEAT

G.C.

G.C.

G.C.

AS PER LOCAL CODE AND FIRE DEPARTMENT

G.C.

5. BOH REFRIGERATOR (REF-2)

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL; COORD. W/ MEP'S; COORD. INSTALL WITH BUILT IN CABINETRY

5. TEMPORARY ELECTRICAL

G.C.

G.C.

6. ADA SIGNAGE

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL PER LOCAL CODE

6. TEMPORARY ENCLOSURE

G.C.

G.C.

7. CLEAN UP

G.C.

G.C.

1. MILLWORK/FIXTURES & FURNITURE

F.C.

F.C.

G.C.

FLOOR, WALL, & FITTING ROOM FIXTURES FURNISHED BY F.C. / INSTALLED BY G.C.

8. INSURANCE

G.C.

G.C.

2. BEST LOCKS

G.C.

G.C.

G.C.

G.C. TO ORDER & PREPAY / G.C. TO INSTALL LOCKS AND PROVIDE 6 SETS OF KEYS

3. DEADLOCK AT BOH DOOR

OWN

G.C.

OWNER TO PROVIDE DEADLOCK AND 6 SETS OF KEYS / F.C. TO STORE AND DELIVER WITH FIXTURE PACKAGE / G.C. TO INSTALL LOCK AT BACK OF HOUSE DOOR

3. SHELVING @ BACK OF HOUSE

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL FROM PIPP; G.C. TO PROVIDE LAYOUT FROM PIPP HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE.

6. MANAGER'S DESK & SHELVES ABOVE

G.C.

G.C.

G.C.

G.C. TO FURNISH AND INSTALL FROM THE CONTAINER STORE; G.C. TO PROVIDE LAYOUT FROM CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE.

OWN

OWN

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

B. DUCTWORK / DIFFUSERS

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

2. TEMPERATURE CONTROLS

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

3. EXHAUST FANS

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

A. WATER

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

B. WASTE

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

C. VENT

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

9. JOB PHONE

G.C.

G.C.

10. FINAL CLEANING

G.C.

G.C.

OLA / MEP ENG

3. MECHANICAL SHOP DRAWINGS AND EQUIPMENT

OLA / MEP ENG

4. ELECTRICAL EQUIPMENT AND DEVICES

OLA / MEP ENG

5. PLUMBING FIXTURES

OLA / MEP ENG

6. STRUCTURAL SHOP DRAWINGS

X

OLA / ENG.

7. STOREFRONT SHOP DRAWINGS AND SAMPLES

X

OLA

06.

2.

3. 4.

5. 6.

7.

8.

9.

12.

SITE WORK X OWN

OWN

OWN'S VEN

5. MANAGER'S CHAIR

3. DEMOLITION

G.C.

G.C.

G.C.

4. LOCKERS

4. SAW CUT/ DRILL SLAB

G.C.

G.C.

G.C.

AS REQUIRED FOR ELECTRICAL, PLUMBING, & FLOORING

G.C.

G.C.

G.C.

1. LEVELING OF CONCRETE FLOOR

G.C.

G.C.

G.C.

2. VAPOR BARRIER

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

X

G.C. TO CONFIRM SLAB CONDITIONS

G.C. PATCH AND REPAIR FLOOR AS REQUIRED, AND PREPARE FOR NEW FLOOR FINISH

2. CONCRETE BLOCK

X

6. PLUMBING FIXTURES

G.C.

G.C.

G.C.

COORD. W/ MECH. DWGS. & PLUMBING SCHEDULE

3. LIME STONE

X

7. WATER HEATER

G.C.

G.C.

G.C.

SEE MECHANICAL DWGS.

8. SPRINKLER SYSTEM

G.C.

G.C.

G.C.

COORD. W/ SPRINKLER DWGS; COORD. W/ EXISTING CONDITIONS

G.C.

G.C.

G.C.

EXISTING TO REMAIN

LL

LL.

LL

WATER COOLER PROVIDED

11. FIRE/SMOKE DAMPER

G.C.

G.C.

G.C.

COORD. W/ MECH. DWGS. & LOCAL CODE REQUIREMENTS

12. FIRE STOP / SMOKE BARRIER

G.C.

G.C.

G.C.

COORD. W/ MECH. DWGS. & LOCAL CODE REQUIREMENTS

G.C.

G.C.

G.C.

SEE ELECTRICAL DWGS.

G.C.

G.C.

G.C.

RELOCATED; COORD. W/ ELECTRICAL DWGS.

G.C.

G.C.

G.C.

SEE ELECTRICAL DWGS.

4. LIGHT SWITCHES

OWN

OWN/VEN

G.C.

SWITCHES PROVIDED BY OWNERS VENDOR; G.C. TO PROVIDE MASTER OVERRIDE SWITCH

5. LIGHT FIXTURES IN CEILING

OWN

OWN/VEN

G.C.

G.C. TO COORD. & INSTALL; G.C. TO PROVIDE LAMPS FOR SM-1 AND P-1 FIXTURES. REF. A-102A RCP

6. LIGHT FIXTURES IN MILLWORK

OWN

OWN/VEN

G.C.

G.C. TO COMPLETE FINAL ELECTRICAL CONNECTION FOR ILLUMINATED MIRRORS

7. EXIT SIGNAGE

OWN

OWN/VEN

G.C.

SEE ELECTRICAL DWGS

8. EXHAUST FAN

G.C.

G.C.

G.C.

SEE ELECTRICAL DWGS.

9. EMERGENCY LIGHTING

OWN

OWN/VEN

G.C.

G.C. TO COORD. W/ NEW WORK DWGS

10. TELEPHONE CONDUIT

G.C.

G.C.

G.C.

11. TELEPHONE JACKS/SETS/WIRES

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

OWN

OWN

14. TIME CLOCK

G.C.

G.C.

G.C.

MULTI-CHANNEL; COORD. W/ ELECTRICAL DWGS.

15. FLOOR OUTLETS

G.C.

G.C.

G.C.

G.C. TO PROVIDE DEDICATED 4-GANG FLOOR BOX WITH COVER; G.C. IS RESPONSIBLE FOR ANY PATCHING AND REPAIRING OF THE FLOORING REQUIRED FOR INSTALLATION OF THE FLOOR BOX; COORD BEFORE SLAB IS POURED.

16. CONDUIT FOR COMPUTER SYSTEM

G.C.

G.C.

G.C.

COORD. W/ BRAND WAVE

17. LIFE SAFETY (F.A.)

G.C.

G.C.

G.C.

G.C. TO COORD W/ MEP ENGINEER

18. CAMERA SECURITY SYSTEM

OWN

OWN

G.C.

MODCLOTH VENDOR FURNISHES & INSTALLS CAMERA WIRING, CAMERA, & CPU; G.C. TO PROVIDE CONDUIT & PULL, SCHEDULE AND COORD. W/ VENDOR

19. SHOPPER TRACK SYSTEM

OWN

OWN

G.C.

G.C. TO PROVIDE PULL STRING AS REQ'D; COORD. W/ VENDOR

METALS X

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED

B. INTERIOR PARTITIONS

G.C.

G.C.

G.C.

G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS

C. FURRING

G.C.

G.C.

G.C.

G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS

3. FRAMING FOR HVAC

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

X

G.C.

4. STOREFRONT SYSTEM

X

G.C.

5. METAL DECKING

X

G.C.

G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/REPLACED

G.C.

G.C.

G.C.

G.C. TO COORD. W/ FIXTURE CONTRACTOR

2. SHELVES

G.C.

G.C.

G.C.

G.C. RESPONSIBLE FOR BACK OF HOUSE SHELVES ONLY; COORD. W/ MODCLOTH

3. COUNTERS

G.C.

G.C.

G.C.

4. PLYWOOD

G.C.

G.C.

G.C.

FOR TELE/DATA BOARD BY G.C.

G.C.

G.C.

G.C.

G.C. TO COORD. ALL MILLWORK BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR

11. BOH SHELVING LAYOUT

OLA / MODCLOTH

1. CAULKING

G.C.

G.C.

G.C.

12. WOOD JOINERY AND MILLWORK

OLA / MODCLOTH

2. SEALANT

G.C.

G.C.

G.C.

G.C. TO PROVIDE A SUBMITTALS SCHEDULE AT CONSTRUCTION KICK-OFF FOR ARCHITECT'S REVIEW

3. WATERPROOFING

G.C.

G.C.

G.C.

PROVIDE WATER PROOFING AT ALL WET AREAS

GENERAL NOTES

4. INSULATION

G.C.

G.C.

G.C.

G.C. TO PROVIDE INSULATION @ STOREFRONT CURB WALLS

G.C.

G.C.

2. BACK OF HOUSE DOOR

G.C.

G.C.

G.C.

3. RESTROOM DOOR

G.C.

G.C.

G.C.

4. DOOR HARDWARE

G.C.

G.C.

G.C.

G.C.

G.C.

G.C.

10. G.C. SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. G.C. SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. 11. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING - CREATED OR EXPOSED DURING CONSTRUCTION, PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES.

G.C.

G.C.

G.C.

NEW RAISED SLAB AND TOPPING SLAB

KEY

DESCRIPTION

B. WALK OFF MATT- ENTRY

G.C.

G.C.

G.C.

NEW REMOVABLE WALK-OFF MAT

G.C. (OR) GC

GENERAL CONTRACTOR

C. FITTING ROOMS & VESTIBULE

G.C.

G.C.

G.C.

NEW WOOD FLOOR; FLOAT TO ALIGN W/ ADJACENT FLOORS

OWN. (OR) OWN

OWNER/TENANT

D. RESTROOM

G.C.

G.C.

G.C.

NEW RAISED SLAB AND TILE

LL

LANDLORD

E. BACK OF HOUSE & STORAGE CLOSET

G.C.

G.C.

G.C.

NEW RAISED SLAB

F.C. (OR) FC

FIXTURE CONTRACTOR

F. LOUNGE

OWN

OWN

OWN

NEW WOOD FLOOR; FLOAT TO ALIGN W/ ADJACENT FLOORS

AV

AUDIO/VISUAL CONSULTANT

X

N/A OR EXISTING

A. SALES AREA

G.C.

G.C.

G.C.

G.C. TO COORD. IN-WALL BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR

N/A

NOT APPLICABLE-DOES NOT APPLY TO PROJECT

B. LOUNGE, FITTING ROOMS & VESTIBULE

G.C.

G.C.

G.C.

G.C. TO COORD. IN-WALL BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR

EXISTING

ALREADY LOCATED ON SITE

C. RESTROOM

G.C.

G.C.

G.C.

ENSURE MOISTURE RESIST. GWB IS INSTALLED IN AND AROUND WET AREAS

PROVIDE

TO FURNISH & INSTALL ( WHEN TENANT RESPONSIBILITY, TENANTS SUPPLIERS TO FURNISH & INSTALL)

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

D. BACK OF HOUSE & STORAGE CLOSET

G.C.

G.C.

G.C.

ENSURE MOISTURE RESIST. GWB IS INSTALLED IN AND AROUND WET AREAS

FURNISH

TO SUPPLY AND DELIVER

PROJECT NO.: 218231

INSTALL

TO INSTALL

DATE: 08/20/2018

A. SALES AREA & LOUNGE

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW PAINTED WOOD BASE

OWN/VEN

OWNER'S VENDOR

DRAWN BY: GR, RE, NK

B. FITTING ROOMS & VESTIBULE

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW PAINTED WOOD BASE

CHECKED BY: JSP

C. RESTROOM

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW TILE BASE

AREA: 1807 SQ.FT

D. BACK OF HOUSE

G.C.

G.C.

G.C.

G.C. TO PROVIDE NEW RUBBER WALL BASE

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

5. CEILING

12. PRIOR TO PROJECT CLOSEOUT, G.C. SHALL COORDINATE WITH THE BUILDING OWNER: ANY TESTS, SUBMITTAL OF AS-BUILT DOCUMENTATION AS REQ'D, AND ALL REQUIREMENTS FOR PROJECT ACCEPTANCE. 13. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.

A. SALES AREA

G.C.

G.C.

G.C.

NEW SUSPENDED GWB CEILING

B. FITTING ROOMS & LOUNGE

G.C.

G.C.

G.C.

NEW SUSPENDED GWB CEILING

C. RESTROOM

G.C.

G.C.

G.C.

NEW SUSPENDED GWB CEILING

G.C.

G.C.

G.C.

EXISTING CEILING; G.C. TO MAINTAIN ACOUSTIC AND FIRE RATED CEILING

G.C.

G.C.

G.C.

OWN

OWN

OWN/VEN

G.C.

G.C.

G.C.

4. POS SYSTEM

OWN

OWN

OWN/VEN

5. STOREFRONT SIGNAGE

OWN

OWN

OWN/VEN

6. DRAPERY

OWN

VEN

G.C.

D. BACK OF HOUSE & STORAGE CLOSET 10.

CONDUIT & PULL STRINGS BY G.C. AS REQ'D; G.C. TO SCHEDULE & COORD. INSTALL W/ VEND

STAMP HERE:

A. SALES AREA

4. BASE

G.C. SHALL COMPLETE ALL WORK WITHOUT DISRUPTION TO ADJACENT BUILDING TENANTS.

G.C./ OWN

RESPONSIBILITY SCHEDULE LEGEND

3. WALLS

G.C. SHALL CONDUCT WORK IN A SAFE AND TIMELY MANNER. PROVIDE AND MAINTAIN ALL NECESSARY GUARDS FOR PREVENTION OF ACCIDENTS. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION, SAFETY ISSUES, CONTROL OR SUPERVISION OF THE WORK, NOR ITEMS RELATED TO STOPPAGE OF WORK. THE AUTHORITY TO STOP WORK REMAINS SOLELY WITH MODCLOTH (OWNER) AND G.C..

X

13. AUDIO SYSTEM

DOOR HARDWARE PROVIDED BY G.C.

2. FINISH FLOORING

G.C. SHALL INSTALL ALL NECESSARY MEANS TO PROTECT THE PUBLIC , THE BUILDING, AND NEW WORK FROM DAMAGE DURING THE DURATION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO FLOOR PROTECTION, TEMPORARY DUST PARTITIONS AND BARRICADES.

X

FINISHES 1. GYPSUM FOR PARTITIONS

ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE HIGHEST QUALITY INDUSTRY STANDARDS FOR MATERIAL AND INSTALLATION. ALL WORK WILL BE WARRANTED FOR ONE YEAR MIN. BY THE G.C. UNLESS STATED OTHERWISE. REPAIR OR REPLACEMENT OF WARRANTED WORK AND ANY AREA AFFECTED BY FAILURE OF WARRANTED ITEM SHALL BE THE G.C.'S RESPONSIBILITY.

X

12. BUZZER

DOORS G.C.

ELECTRICAL

3. TRANSFORMER

1. BLOCKING

X

X

2. PANELS

MOISTURE CONTROL

G.C. IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.

14.

CARPENTRY

1. ENTRY DOOR

X

1. DISTRIBUTION

OLA

G.C. SHALL THOROUGHLY REVIEW ALL EXISTING CONDITIONS PRIOR TO BIDDING. ANY DISCREPANCIES BETWEEN THE BID DOCUMENTS AND EXISTING CONDITIONS SHALL BE BROUGHT THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO BIDDING.

9. WATER METER 10. WATER FOUNTAIN

10. PAINT DRAW DOWNS

09.

X

X

5. FURRING

ALL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP.

G.C. TO SCHEDULE AND COORD. DELIVERY

1. BRICK

OLA / MODCLOTH

G.C. SHALL FILE ANY NECESSARY CERTIFICATES OF INSURANCE WITH THE LOCAL DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED.

OWN/ G.C.

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

5. PLUMBING

MASONRY

9. FLOOR FINISH SAMPLES

G.C. SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS, FEES, APPROVALS, AND TEST FOR THE WORK. ALL CONSTRUCTION AND MATERIALS SHOULD COMPLY WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS / LAWS / CODES.

OWN/F.C.

MECHANICAL

A. UNIT

CONCRETE SLAB

X

MEP ENGINEER:

1. HVAC

OLA

07.

13.

FURNISHED AND INSTALLED BY SIGNAGE VENDOR; G.C. TO SUPERVISE AND COORD. INSTALL

FURNISHINGS

2. BARRICADE GRAPHICS

8. DOORS AND HARDWARE

08. 1.

SPECIAL INSPECTOR CONTRACTED BY OWNER(MODCLOTH); G.C. TO COORD. SCHEDULE AND ACCESS TO SITE FOR INSPECTIONS

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

EQUIPMENT

G.C.

A. TENANT DEMISING WALLS

2. FIRE ALARM SHOP DRAWINGS AND DEVICES

COMMENTS

3. FIRE EXTINGUISHER

2. METAL STUDS

OLA / MEP ENG.

INSTALL

OWN/VEN

4. EXPANSION JOINT MATERIAL

1. SPRINKLER SHOP DRAWINGS AND DEVICES

FURNISH

OWN/VEN

3. CONCRETE SLAB

PROVIDE

PROVIDE

OWN/VEN

BANDWAVE SYSTEMS, LLC ADIL ZAIDI 438 HIGH ST BURLINGTON, NJ 08016 P: 888-396-7182 M: 609-699-4265 AZAIDI@BANDWAVESYSTEMS.COM

N/A

EXISTING

2. INTERIOR LED SIGNS

1. STRUCTURAL STEEL

DESCRIPTION

BUILDING PERMIT FEE BY OWNER(MODCLOTH); CONTRACTOR SPECIFIC PERMITS INCLUDING, FIRE ALARMS, SPRINKLER, PLUMBING & ELECTRICAL BY G.C. ( IF APPLICABLE)

N/A

OWN/VEN

X

G.C. REQUIRED SHOP DRAWINGS

DESCRIPTION

OWN/VEN

6. ENTRY VESTIBULE FLOORING

05.

COMMENTS

OWN/VEN

X

FIRECLAY TILE SARAH ROORDA PH: 646-520-9523 SARAH@FIRECLAYTILE.COM

INSTALL

1. STOREFRONT SIGNS

5. SIDE WALK

RESTROOM TILE

FURNISH

11.

DATA

04.

PROVIDE

GENERAL REQUIREMENTS

1. BARRICADE

03.

ARCHITECT OF RECORD:

RESPONSIBILITY SCHEDULE

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

REQUIRED VENDORS CONTACT INFO

X

SPECIALTIES 1. TOILET ROOM ACCESSORIES 2. SPEAKERS- AUDIO SYSTEM 3. STOREFRONT SYSTEM

X

CONDUIT & PULL STRINGS BY G.C. AS REQ'D; G.C. TO SCHEDULE & COORD. INSTALL W/ VENDOR

FURNISHED AND INSTALLED BY SIGNAGE VENDOR; G.C. TO SUPERVISE AND COORD. INSTALL FURNISHED BY OWN. VENDOR; DELIVERED TO G.C. FOR INSTALLATION

RESPONSIBILITY SCHEDULE

G-002.00 SHEET 3 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

POINT B FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

3' - 0"

CLEAR

3' - 0"

CLEAR

0" 3' R EA CL

CLEAR

EXIT 1

3' - 0"

CLEAR

3' - 0"

FE

3' - 0" CLEAR 3' - 0"

FE

POINT C

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

CLEAR

TRAVEL DISTANCE FROM POINT A: 38'-0" TRAVEL DISTANCE FROM POINT B: 51'-9"

POINT A

TRAVEL DISTANCE FROM POINT C: 67'-8"

1

EGRESS PLAN SCALE: 1/4" = 1'-0"

EGRESS PLAN HATCH AND SYMBOL LEGEND SYMBOL

DESCRIPTION EXISTING PARTITION TO REMAIN

FIRE EXTINGUISHER NOTE: ADA COMPLIANT TYPE "ABC" ALL PURPOSE CHEMICAL FIRE EXTINGUISHER & MOUNTING BRACKET TO BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR AT A HEIGHT OF 5'-0" MAX. SPECIFICATIONS:

2" MIN

MOUNTING BRACKET AS REQUIRED

(48" MAX.)

1' - 0"

FIRE EXTINGUISHER

3' - 4"

NEW PARTITION

36" MIN

4"

STAMP HERE:

FIRE EXTINGUISHER: BY ANSUL NAMED "SENTRY 10" MODEL NO: AA10S PART NO: 436500 AGENT CAPACITY: 10 LBS. FORAY U.L. RATING: 4A:80B:C HEIGHT: 20.5 IN BRACKET: 435793

EGRESS PATH

1. IT IS THE RESPONSIBILITY OF THE TENANT OR TENANT'S G.C. TO FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS.

STORE AREA & EGRESS CALCULATING SPACE TYPE/ NAME

SF AREA

OCCUPANCY LOAD

TOTAL %

3. IT IS THE RESPONSIBILITY OF TENANT'S G.C. TO FIELD VERIFY EXISTING ELECTRICAL SERVICE AND TO MAKE ANY AND ALL MODIFICATIONS REQUIRED TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED ELECTRICAL SERVICE.

SALES AREA

1354 SF (GROSS)

SF / 60 = 23 OCCUPANT

75.0%

4. ENSURE THAT LAYOUT AND ALL FIXTURES COMPLY WITH LATEST CODE AND ADA REQUIREMENTS.

STOCK ROOM

396 SF (GROSS)

SF / 300 = 2 OCCUPANT

22.0%

RESTROOM

57 SF (GROSS)

SF / 300 = 1 OCCUPANT

3.0%

2. NOTHING SHALL BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THROUGH THE FLOOR OR ROOF DECK ABOVE.

5. FIRE EXTINGUISHER SHALL BE PLACED NO LESS THAN 12 INCHES ADJACENT TO THE DOOR FROM THE FORWARD APPROACH.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 ILLUMINATED EXIT SIGNAGE ABOVE; REF. RCP FOR FULL SPEC AND LOCATION

FE

EGRESS PLAN GENERAL NOTES:

TOTAL

1807 SF (GROSS)

26 OCCUPANTS

100 %

DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP

EXIT CAPACITY - PROVIDED

AREA: 1807 SQ.FT EXIT

WALL MOUNTED FIRE EXTINGUISHER

WIDTH

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

6'-0" CLEAR (72")

1

EXIT CAPACITY - REQUIRED OCCUPANTS WALL BASE AS SCHEUDLED 26 FINISHED FLOOR AS SCHEUDLED

4

SCALE: 1 1/2" = 1'-0"

5.2"

NOTE: TOTAL WIDTH REQUIRED LESS THAN MINIMUM REQUIRED EXIT WIDTH OF 32" CLEAR

TRAVEL DISTANCE ROUTE

FIRE EXTINGUISHER DETAIL

X INCHES/ OCCUPANT 0.20 (INCHES PER OCCUPANT)

DISTANCE

POINT A

38'- 0" (<75' MAX DISTANCE TO EXIT FROM TENANT SPACE TO EXIT)

POINT B

51'- 9" (<75' MAX DISTANCE TO EXIT FROM TENANT SPACE TO EXIT)

POINT C

67'- 8" (<75' MAX DISTANCE TO EXIT FROM TENANT SPACE TO EXIT)

EGRESS AND ACCESSIBILITY PLAN

G-003.00 SHEET 4 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

DURING DEMO FIRE SPRINKLER SYSTEM MUST BE BLANKED OFF PRIOR TO COMMENCING DEMOLITION MEP ENGINEER:

G.C. TO VERIFY SITE CONDITIONS OF EXISTING DEMISING WALL IN FIELD AND INCLUDE ALLOWANCE FOR GYP. BOARD ON DEMISING STUDS AS REQUIRED.

2

1

10

12

TYP.

NOTE: GC TO FURNISH & INSTALL TEMPORARY CONSTRUCTION GRAPHIC AT INTERIOR SIDE OF STOREFRONT, INCLUDING REMOVAL OF VINYL GRAPHIC AT TURNOVER. GC TO USE OWNER'S ARTWORK ONLY.

TYP. FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

7 3

9 10

TYP.

4 5 2 8

TYP. 12

+/- 3 1/4" V.I.F.

5

TYP.

11

TYP.

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

6

3

1 10

TYP.

9

10

10

1 1

1

TYP.

TYP. 3

DEMOLITION PLAN SCALE: 1/4" = 1'-0"

STAMP HERE:

HATCH & SYMBOL LEGEND HATCH / SYMBOL

DESCRIPTION

EXISTING PARTITION TO REMAIN

EXISTING TO BE DEMOLISHED

DEMOLITION PLAN GENERAL NOTES: 1. G.C. TO MAINTAIN THE INTEGRITY OF THE FIRE AND LIFE SAFETY SYSTEMS THROUGHOUT THE SCOPE OF THE WORK WITHIN THE PREMISES.

DEMOLITION PLAN KEY NOTES: 1

LEASE LINE

2

EXISTING 1-HR FIRE-RATED DEMISING PARTITION TO REMAIN; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH; COORD. W/ NEW WORK DWGS.

3

EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION

2. G.C. SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY, NEATLY AND IN A SYSTEMATIC MANNER. 3. ALL EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DAMAGE AND SHALL MAKE ADDITIONAL REPAIRS WITHOUT ADDITIONAL COSTS TO OWNER.

4

4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN. 5

5. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING MECHANICAL EQUIPMENT.

G.C. TO REPAIR OR REPLACE EXISTING THRESHOLD AT STOREFRONT ENTRY; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)

DATE: 08/20/2018 CHECKED BY: JSP

6

EXISTING AHU ABOVE TO REMAIN; COORD. W/ NEW WORK MEP DWGS.

7. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING PLUMBING FIXTURES.

7

EXISTING LINE VOLTAGE ELECTRICAL PANEL TO BE RELOCATED; G.C. TO RE-CIRCUIT AS REQUIRED; REF. NEW WORK ELECTRICAL DWGS.

8

EXISTING CONCRETE SLAB TO REMAIN; PREP FOR NEW RAISED FLOOR FINISH; COORD. W/ NEW WORK DWGS.

9

EXISTING SHAFT TO REMAIN; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE RATING AND PREP FOR NEW PAINT FINISH

10

EXISITNG ROUND CONCRETE COLUMN TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION AND PREP TO RECIEVE NEW POLISHED FINISH; REF. A-104

11

G.C. TO ALERT ARCHITECT IMMEDIATELY IF DIMENSIONS VARY ON SITE

12

EXISTING CONCRETE COLUMN TO REMAIN: GC TO PROTECT THROUGHOUT CONSTRUCTION

9. G.C. TO REMOVE EXISTING BASE, CEILING, AND FLOOR MOLDING, AS WELL AS SHELVING AND FIXTURES. 10. G.C. TO REMOVE AND DISCARD ALL ABANDONED LOOSE FIXTURES, CEILING AND LIGHT FIXTURES. 11. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING DEMOLITION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE. 12. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF THE BUILDING CODE. 13. THE GENERAL CONTRACTOR SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION.

PROJECT NO.: 218231

EXISTING STOREFRONT ENTRY DOOR AND HARDWARE TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION

6. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRICAL AND TELEPHONE PANELS.

8. G.C. TO REMOVE EXISTING FLOORING TO SUBFLOOR AND PREPARE SURFACE FOR NEW FLOORING.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

DEMOLITION PLAN

D-100.00 SHEET 5 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

1 10

4 7

3

4

4

TYP.

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

TYP.

10

7

5

TYP.

4 4

4

9

8

5

3

TYP. 1

TYP.

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

6

AHU

6

1

7 4

2

TYP.

4

TYP.

4

1

1

DEMOLITION REFLECTED CEILING PLAN

STAMP HERE:

SCALE: 1/4" = 1'-0"

HATCH & SYMBOL LEGEND HATCH

DESCRIPTION

EXISTING PARTITION TO REMAIN

EXISTING TO BE DEMOLISHED SYMBOL

DESCRIPTION

EXISTING UPRIGHT SPRINKLER HEAD; INDICATES EXISTING TO BE RELOCATED COORD. W/ NEW WORK DWGS AND APPROVED SPRINKLER DWGS.

DEMO REFLECTED CEILING PLAN GENERAL NOTES: 1. G.C. TO MAINTAIN THE INTEGRITY OF THE FIRE AND LIFE SAFETY SYSTEMS THROUGHOUT THE SCOPE OF THE WORK WITHIN THE PREMISES. 2. G.C. SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY, NEATLY AND IN A SYSTEMATIC MANNER. 3. ALL EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DAMAGE AND SHALL MAKE ADDITIONAL REPAIRS WITHOUT ADDITIONAL COSTS TO OWNER. 4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.

DEMO REFLECTED CEILING PLAN KEY NOTES: 1

LEASE LINE

2

EXISTING AHU ABOVE TO REMAIN; COORD. W/ NEW WORK MEP DWGS.

3

G.C. TO CONFRIM EXTENT OF 2HR RATED ACOUSTIC CEILING DEMOLITION REQ'D; COORD. WITH EXTENT OF NEW WORK SCOPE. G.C. TO MAINTAIN FIRE AND ACOUSTIC RATING AT EXISTING LANDLORD GYPSUM CEILING AND CONDUIT.

4

EXISTING LIGHTING AT GWB CEILING TO BE REMOVED BACK TO SOURCE U.N.O., TYP.

5

EXISTING OUTSIDE AIR DUCT ABOVE CEILING TO REMAIN; G.C. TO CLEAN, SERVICE, AND FINISH TO MATCH NEW CEILING COLOR; COORD. W/ NEW WORK RCP AND MEP DWGS.

6

EXISTING SUPPLY GRILLE AND ASSOCIATED DUCTING TO BE RECONFIGURED; COORD. W/ NEW WORK RCP AND MEP DWGS.

7

EXISTING SPRINKLER PIPES TO REMAIN; EXISTING UP RIGHT SPRINKLER HEADS TO BE REMOVED; COORD. SCOPE WITH NEW WORK RCP, MEP & APPROVED SPRINKLER DWGS. G.C. TO VERIFY WITH NEW WORK RCP THAT EXISTING LOCATION ALIGNS WITH OTHER CEILING FIXTURES PER A102.

5. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING MECHANICAL EQUIPMENT. HVAC RETURN GRILLE; INDICATES EXISTING TO REMAIN

6. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRICAL AND TELEPHONE PANELS. 7. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING PLUMBING FIXTURES.

HVAC SUPPLY GRILLE INDICATES EXISTING TO REMAIN

ACCESS PANEL; EXISTING TO REMAIN LIGHTS; EXISTING TO BE RELOCATED EXIT SIGN; EXISTING TO BE REMOVED AND RELOCATED EXITING SUPPLY DUCT; EXISTING TO REMAIN

8. G.C. TO REMOVE EXISTING FLOORING TO SUBFLOOR AND PREPARE SURFACE FOR NEW FLOORING.

8

EXISTING RATED ACCESS PANEL TO BE REMAIN

9. G.C. TO REMOVE EXISTING BASE, CEILING, AND FLOOR MOLDING, AS WELL AS SHELVING AND FIXTURES.

9

EXISTING EXIT SIGN TO REMOVED AND RELOCATED; COORD. W/ NEW MEP DWGS.

10

EXISTING CEILING OPENING; G.C. TO CONFIRM IF RATED ACCESS PANEL IS REQ'D. G.C. TO PATCH OPENINGS TO MATCH CURRENT CEILING FIRE AND ACOUSTIC RATING IF PANEL NOT REQ'D

10. G.C. TO REMOVE AND DISCARD ALL ABANDONED LOOSE FIXTURES, CEILING AND LIGHT FIXTURES. 11. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING DEMOLITION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE. 12. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF THE BUILDING CODE. 13. THE GENERAL CONTRACTOR SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

DEMOLITION REFLECTED CEILING PLAN

D-101.00 SHEET 6 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671 1

MEP ENGINEER:

3 FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM 5

TYP. 2

3

8

6 5

F

4

TYP.

TYP.

5

FACP

7

TYP.

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

9

1

5

TYP. 1

9

5

TYP.

TYP.

5

1

1

DEMOLITION POWER AND SIGNAL PLAN

STAMP HERE:

SCALE: 1/4" = 1'-0"

HATCH & SYMBOL LEGEND HATCH

DESCRIPTION

EXISTING PARTITION TO REMAIN EXISTING TO BE DEMOLISHED SYMBOL

T

TS

TM

FACP F

DEMOLITION GENERAL NOTES: 1. G.C. TO MAINTAIN THE INTEGRITY OF THE FIRE AND LIFE SAFETY SYSTEMS THROUGHOUT THE SCOPE OF THE WORK WITHIN THE PREMISES. 2. G.C. SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY, NEATLY AND IN A SYSTEMATIC MANNER.

DESCRIPTION WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE; EXISTING TO BE REMOVED

3. ALL EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DAMAGE AND SHALL MAKE ADDITIONAL REPAIRS WITHOUT ADDITIONAL COSTS TO OWNER.

SWITCH; EXISTING TO BE REMOVED

4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.

THERMOSTAT; EXISTING TO BE RELOCATED; REF. MEP DWGS. TEMPERATURE SENSOR; EXISTING TO BE REMOVED AND REPLACED; REF. MEP DWGS. TIME-CLOCK; EXISTING TO BE REMOVED FIRE ALARM CONTROL PANEL; EXISTING TO REMAIN FIRE ALARM PULL STATION EXISTING TO BE RELCATED AND CONCEALED WITHIN WALL

DEMOLITION POWER AND SIGNAL PLAN KEY NOTES 1

LEASE LINE

2

EXISTING LINE VOLTAGE ELECTRICAL PANEL ABOVE TO BE RELOCATED; G.C. TO RE-CIRCUIT AS REQUIRED; REF. NEW WORK ELECTRICAL DWGS.

3

EXISTING CEILING OPENING; G.C. TO CONFIRM IF RATED ACCESS PANEL IS REQ'D; G.C. TO PATCH OPENINGS TO MATCH CURRENT CEILING FIRE AND ACOUSTIC RATING IF PANEL IS NOT REQ'D

4

EXISTING SWITCHING TO BE REMOVED U.N.O, TYP.

5

EXISTING WALL MOUNTED DUPLEX RECEPTACLE TO BE REMOVED.

6

EXISTING FIRE ALARM PULL STATION TO BE RELOCATED TO BE CONCEALED WITHIN THE WALL; COORD. W/ APPROVED FIRE ALARM DWGS.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018

5. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING MECHANICAL EQUIPMENT.

7

EXISTING FIRE ALARM CONTROL PANEL TO REMAIN; COORD. W/ APPROVED FIRE ALARM DWGS.

DRAWN BY: GR, RE, NK

6. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRICAL AND TELEPHONE PANELS.

8

REMOVE ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING BACK TO THEIR SOURCE

CHECKED BY: JSP

7. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING PLUMBING FIXTURES.

9

EXISTING ACCESS PANEL TO REMAIN

8. G.C. TO REMOVE EXISTING FLOORING TO SUBFLOOR AND PREPARE SURFACE FOR NEW FLOORING.

AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

9. G.C. TO REMOVE EXISTING BASE, CEILING, AND FLOOR MOLDING, AS WELL AS SHELVING AND FIXTURES. 10. G.C. TO REMOVE AND DISCARD ALL ABANDONED LOOSE FIXTURES, CEILING AND LIGHT FIXTURES. 11. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING DEMOLITION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE. 12. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF THE BUILDING CODE. 13. THE GENERAL CONTRACTOR SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION.

DEMO POWER AND SIGNAL PLAN

D-102.00 SHEET 7 OF 27


ARCHITECT OF RECORD:

1

2

A-300.00

A-301.00 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

40' - 2 1/8" 3 7/8"

7 1/4" 1' - 4"

NOTE: VERIFY ALL DIMENSIONS WITH LOD AND V.I.F. GC ARE TO NOTIFY ARCHITECT'S OFFICE WITH ANY CONFLICTS PRIOR TO MATERIAL PURCHASE AND WORK COMMENCEMENT.

13' - 11 1/4"

14

4 1/4"

BIDDERS ARE REQUIRED TO HAVE SITE WALK THROUGH DURING BIDDING PROCESS. BIDDERS ARE TO COORDINATE THROUGH TENANT AND MALL MANAGER TO GAIN ACCESS. BIDDERS TO VERIFY SITE CONDITIONS FOR ALL DISCIPLINES PRIOR TO SUBMITTING PRICING.

3

14

V.I.F

3' - 10"

1

" '-4 R1

7

4' - 10 7/8"

3' - 10"

3' - 10"

FR 1

STORAGE CLOSET

FR 2

FR 3

04

05

06

07

1 A-307.00

3 3/4"

7' - 3 1/8" HOLD ADA RESTROOM 11

1 MEP ENGINEER:

14

14

2' - 0 5/8"

30 6

2

B

D 7

5

EX-01

3' - 4 1/8"

3

14 B 9

21

B

14

13

4' - 10"

9

4' - 10"

04

CAB

6' - 10"

A

4 1/4"

A 13

4' - 1 5/8"

DOOR BACK OF HOUSE

REF

14 A

21' - 5"

2

27 2

21' - 1 1/4"

3

7' - 3 5/8"

15

24 4

8' - 10"

6' - 6" FACP

STORAGE CLOSET

13

3' - 0"

01

6

03

A

HOLD

SALES

10

15

12

HOLD

1' - 6 5/8"

5

A-305.00 6

14

A

A-305.00 4

13

5

11' - 6"

1

B

10

14

14

2

ALIGN 2' - 6" C

5' - 4 3/4" HOLD

ADA FR

09

A-304.00 4

1' - 3"

13

FR 5

B

15

A-302.00 1

4

8

A-306.00 3

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

D

1 C

C

02

B VESTIBULE

DOOR

R1 '-4 "

4' - 11 1/8"

3' - 5 7/8"

13

14

42' - 4 1/4"

D

EQ

C

3' - 0"

R1 '-4 "

1' - 4 3/4"

2' - 0"

G

1' - 7"

EQ

3' - 0"

2' - 4 5/8"

1' - 7"

3' - 0"

1' - 3 1/8"

12

6' - 8 1/2"

A-301.00

FR 4 9 08

18

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

DOOR

21

4' - 8 1/2"

1' - 9 1/4"

4' - 6 3/4"

4

03

13 A-304.00 11

13

94 °

1

A

3

FITTING ROOM LOUNGE

5"

7 1/4"

G

20

4' - 6 1/4"

4

13

HOLD

5' - 0"

A-303.00 3

14

4' - 9 3/8"

12' - 7 1/4"

NOTE: DRYWALL CLOSURE MAINTAINED FROM FLOOR TO UNDERSIDE OF DECK ABOVE. ALL VOIDS, PENETRATIONS, SHAFT OPENING AND JOINTS ARE TAPED AND FIRE STOPPED AS REQ'D.

2

7 1/4"

26 17 19

4' - 6"

13

E

3' - 0"

" -4

NOTE: GC TO IDENTIFY POTENTIAL ACCESS PANEL LOCATIONS & COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION

14

13

12 13

1

14

11

02

29

B

10"

1'

2

A-304.00 10

21 14

LOUNGE

A 8 A-305.00 10 A

06

HOLD

R

ALL PENETRATIONS MADE TO LL'S RATED CONCRETE SLAB AND/OR RATED CMU WALL AND/OR RATED DEMISING WALLS ARE TO BE FIRE STOP WITH RATED SEALANT TO MAINTAIN THE RATING. ALL PENETRATES THRU RATED FLOOR AND WALLS ARE REQUIRED TO OBTAIN LL'S APPROVAL IN ADVANCE OF WORK COMMENCEMENT.

8

7

B

24

2' - 0 5/8"

2' - 8 1/2"

9 7/8" 1' - 11 1/4"

7

23

8' - 0"

C

5" 2' - 8 7/8"

NOTE: THE INTEGRITY OF ALL EXISTING FIRE SEPARATIONS SHALL BE MAINTAINED. GC TO APPLY MISSING FIREPROOFING WHERE APPLICABLE TO MAINTAIN REQ'D RATING

9' - 2"

HOLD

NOTE: INSTALL UL LISTED FIRE EXTINGUISHERS. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN CONFORMANCE WITH LOCAL FIRE CODE.

21

7' - 0 1/2"

86 °

D

2' - 0" DOOR

2' - 0"

NOTE: SEE MEP AND STRUCTURAL DRAWINGS FOR HVAC SYSTEM AND ADDITIONAL STRUCTURAL FRAMING

3

4

29

5

1

21

1

21

14' - 3 7/8" 1' - 6 1/4"

4' - 8 1/2"

2' - 8"

V.I.F.

F

ALIGN 28

2 14

ALIGN

13 29 4

22 16

13 A

4

1

13

2' - 0"

4

41' - 3"

5 7/8"

23

1"

05 7

HOLD

ALIGN

A

2

E

2' - 0"

11

V.I.F.

12

2' - 11"

25

20

2' - 8 5/8"

5' - 10" 7

4' - 10 5/8"

DOOR

LEASELINE TO LEASELINE

CONSTRUCTION PLAN

1

STAMP HERE:

SCALE: 1/4" = 1'-0"

HATCH & SYMBOL LEGEND HATCH / SYMBOL

DESCRIPTION

EXISTING PARTITION TO REMAIN

CONSTRUCTION PLAN GENERAL NOTES: 1. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLAN(S) AND EXISTING CONDITIONS. 2. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER.

NEW PARTITION

ROOM NAME

01

101

ROOM TAG

4. ALL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. TO REMAIN MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP.

DOOR TAG; REF. A-601

5. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING CONSTRUCTION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE.

PARTITION TYPE TAG; REF. A-600

A

3. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL OR COLUMN U.N.O. DO NOT SCALE DRAWINGS UNDER ANY CIRCUMSTANCES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER THE SCALE ON THE CONSTRUCTION DOCUMENTS.

6. G.C. TO USE 5/8" TYPE 'X' GYPSUM BOARD THROUGHOUT PROJECT.

CONSTRUCTION PLAN KEY NOTES: 15. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS.

1

LEASE LINE

19

SLOPE FLOOR TO DRIAN AT RESTROOM

2

G.C. TO INSTALL WINDOW GRAPHICS PRIOR TO CONSTRUCTION; COORD. W/ OWNER FOR GRAPHICS; OWNER TO SUBMIT GRPAHICS TO LANDLORD FOR APPROVAL PRIOR TO INSTALL

20

G.C. TO USE MOISTURE-RESISTANT TYPE "X" GYP. BOARD AT THE WALLS IN WET AREAS, INCLUDING RESTROOM AND AROUND THE VICINITY OF THE MOP SINK, TYP.

3

EXISTING 1-HR FIRE-RATED DEMISING PARTITION TO REMAIN; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH

21

G.C. TO PROVIDE FRT PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND FIXTURE CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION

16. FIRE EXTINGUISHERS SHALL BE INSTALLED AS REQ'D BY LOCAL AUTHORITY HAVING JURISDICTION. 17. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING CREATED OR EXPOSED DURING CONSTRUCTION,PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 18. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UL STANDARDS FOR THROUGH PENETRATION FIRESTOP SYSTEMS. THE G.C. SHALL SUBMIT SHOP DRAWING DETAILS THAT THE INSPECTOR MAY REQUIRE. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES CLEARLY DEFINED. 19. ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING THERMAL INSULATION - CREATED OR EXPOSED DURING CONSTRUCTION - SHALL BE RESTORED TO FULL CAPACITY. 20. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.

4

EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION

5

EXISTING THRESHOLD AT STOREFRONT ENTRY TO BE REPLACED; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)

6

EXISTING STOREFRONT ENTRY DOOR REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION

22

G.C. TO PROVIDE PLASTEX POLYWALL WATERPROOF PANEL UP TO 48" AFF BEHIND AND AROUND MOPSINK, REF. ELEVATIONS; REF. A-104 FOR SPEC.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

23

NEW HIDDEN DOOR; COORD. W/ ELEVS. AND DETAILS FOR INSTALL HEIGHTS AFF.

PROJECT NO.: 218231

24

EXISTING CONCRETE COLUMN AND FINISH TO REMAIN; G.C. TO PROTECT DURING CONSTRUCTION.

25

G.C. TO PROVIDE POWDER COATED SHEET METAL, TIGHT WRAP EXISTING BULDING PIPING; FINISH TO MATCH PT-02

CHECKED BY: JSP

26

EXISTING 2-HR RATED SHAFT ENCLOSURE; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH AND REPAIR AS REQ'D TO RESTORE ORIGINAL FIRE AND SOUND RATING

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

7

EXISITNG ROUND CONCRETE COLUMN TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION AND PREP TO NEW POLISH AND GRIND FINISH; REF. A-104

8

EXISTING AHU ABOVE TO REMAIN; COORD. W/ MEP DWGS.

27

BUILT IN CABINETRY, REF. MILLWORK DETAILS ON SHEET A-400

9

NEW LOCATION OF EXISTING ELECTRICAL PANEL; COORD. W/ MEP DWGS.

28

EXISTING SHAFT ENCLOSURE AND ACCESS PANEL TO REMAIN; GC TO MAINTAIN REQ'D FIRE RATING

9. METAL STUDS SHALL EXTEND UP TO THE DECK ABOVE WHERE NOTED AND APPLICABLE.

10

EXISTING FIRE-ALARM CONTROL PANEL; COORD. W/ MEP DWGS.

29

PERIMETER BASEBOARDS LOCATED BELOW DISPLAY PLATFORM; COORD. W/ MEP DWGS.

10. PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADERS AND JAMBS, AND AS REQUIRED TO MAKE ASSEMBLY RIGID.

11

EXISITING BUILDING PIPES TO REMAIN; G.C. TO PROVIDE ACCESS PANEL IN NEW BUILT PLATFORMS IF REQ'D.

30

G.C. TO BUILD OUT WALL TO ALIGN W/ FACE OF FIRE ALARM DEVICES AND CONCEAL EXPOSED CONDUIT

A101

11. G.C. TO COORD. NEW WORK W/ FIXTURE PLAN. REF. A-101 FIXTURE PLAN FOR FIXTURE INFORMATION.

12

1 A101

12. G.C. SHALL SUPPLY AND INSTALL PROPER AND ADEQUATE BLOCKING TO SUPPORT ALL OWNER SUPPLIED AND MILLWORK APPLIED/INSTALLED ITEMS FOR FIRM, LEVEL, AND SECURE INSTALLATION OF SUCH ITEMS ON WALLS, COLUMNS, ETC. IF REQUIRED BY CODE ALL SUCH BLOCKING AND SUPPORTS SHALL BE FIRE RETARDANT TREATED TO MEET SUCH REQUIREMENTS. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE IN COMPLIANCE WITH IBC SECTION 2304.9.5.

EXISITING BUILDING SIAMESE CONNECTION TO REMAIN; G.C. TO PROVIDE ACCESS PANEL IN NEW BUILT PLATFORMS IF REQ'D.

13

NEW PARTITION TO EXISTING SOUND RATED CEILING ABOVE; REF. A-600 FOR PARTITION SCHEDULE

14

NEW PARTIAL HEIGHT PARTITION; REF. A-600 FOR PARTITION SCHEDULE

15

NEW DOOR, FRAME, AND HARDWARE; REF. A-601 FOR DOOR AND HARDWARE SCHEDULES

13. FOR ALL WOOD MEMBERS REQUIRED BY CODE TO BE FIRE-RETARDANT TREATED, PROVIDE PRESSURE IMPREGNATION WITH FIRE-RETARDANT CHEMICALS TO PROVIDE UL PRS FIRE HAZARD CLASSIFICATION. ALL SUCH WOOD MEMBERS SHALL BE IDENTIFIED WITH A UL LABEL.

16

NEW MOP SINK, FAUCET, AND SHELF-MOUNTED WATER HEATER ABOVE; COORD. W/ MEP DWGS.

17

NEW RESTROOM W.C. AND LAVATORY; COORD. W/ MEP DWGS.

14. G.C. TO COORD. NEW WORK W/ RCP.; REF. A-102 RCP FOR SOFFIT / LIGHTING INFORMATION.

18

NEW FLOOR DRAIN AT RESTROOM; COORD. W/ MEP DWGS; VERIFY EXACT LOCATION IN FIELD

7. ALL OUTSIDE CORNERS AT DRYWALL PARTITIONS AND FURRING TO HAVE METAL CORNER BEADS. TAPE, PLASTER, AND SAND SMOOTH. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. 1 A101

1

ELEVATION TAG

DETAIL SECTION TAG

DETAIL CALLOUT TAG

8. ACCESS PANELS IN WALL / CEILING FOR PLUMBING, MECHANICAL, ELECTRICAL ACCESS SHALL BE FLUSH FRAMELESS SQUARE CORNER GYP. BOARD PANELS, SEE RCP A-102 FOR SPECIFICATION.

DATE: 08/20/2018 DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT

CONSTRUCTION PLAN

A-100.00 SHEET 8 OF 27


ARCHITECT OF RECORD:

HATCH & SYMBOL LEGEND SYMBOL

DESCRIPTION 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

EXISTING PARTITION TO REMAIN

NEW PARTITION ROOM NAME

04

05

SH.06

FURNITURE / FIXTURE / EQUIPMENT TAG

WALL MOUNTED SHELVING BRACKET

16"

EMPLOYEE LOCKER DISPLAY BUNK DOUBLE HANG

12"W x 18"D x 72"H 54" L X 24" D X 95" H

F.02

DISPLAY BUNK SHELF HANG

54" L X 24" D X 95" H

F.C.

BS BST

WALL MOUNTED STANDARD TOP TRACKS BAR STOOL WALL MOUNTED STANDARD

VARIES 15"Ø x 27"H 84"H

CB

COAT HANG BAR

20"L x 1 3/8"D x 2 3/4"H

CF

2-DRAWER LOCKING FILING CABINET

16-1/4" x 15-3/4" x 29" H

CH-01 CH-2 CH-03 CPT-01 DSK

LARGE TABLE SMALL ROUNDER

F.21 F.23 F.24 F.25 F.26 FB-01

ROUND TABLE WITH TULIP LEG DISPLAY PLATFORM STANDING RACK MONDRIAN SCREEN CONCIERGE DESK FITTING ROOM CURTAIN

FDSK GB

BOH DESK ADA GRAB BARS

HS

HANGING SYSTEM - MERCHANDISING TRACK

KB MQ MR

KEY BOX MANNEQUIN RESTROOM MIRROR

24"W X 38"L X 63"H 24"W X 38"L X 63"H 90" L X 23.25" D X 83" D 42"L x 20"W x 17"H 72"L x 36"W x 30"H 36" Ø x 15"H

F.C. TBD

42"Ø x 30"H 32" D X 28.25" H (LENGTH VARIES) REF. PLANS 1"SQ. X 62"L X 63"H 108" H (LENGTH VARIES) REF. PLANS REF. PLANS REF. PLANS 35 3/8'W x 19 5/8"H 18"L, 36"L, 42"L

16"D (LENGTH VARIES)

SH.01

MOBILE SHELVING

SH.03

SHELVING

1' 10 3/4"W x 2'D x 9'H

SH.04

SHELVING

1'6"W x 2'D x 9'H

5W' x 2'D x 9'H

RECESSED PAPER TOWEL DISPENSER

19"H X 13"W X 4 1/4"D

TDSH

TELE/DATA SHELF

19"L x 14 3/4"D x 4"H

TPH

TOILET PAPER HOLDER

2 1/2"W X 3"D X 6"H

UH

UTILITY HOLDER

10"L x 4"D x 2 3/4"H

G.C.

TBD

OWNER (MODCLOTH)

WHITE METAL

G.C.

BRASS

BONOBOS G.C.

WHITE

G.C.

TBD TBD TBD CPT-01

TBD OWNER (MODCLOTH) OWNER (MODCLOTH) OWNER (MODCLOTH)

WHITE

G.C.

WHITE

G.C.

WD-01/MT-01

F.C.

WD-01/MT-01

F.C.

MT-01 MT-01 WD-01/MT-01

F.C. F.C. F.C.

WD-01

F.C.

WD-02

F.C.

ADA RESTROOM

1

FINISH: WHITE

7 1 4 1 1

FINISH: MT-01

2 1

G.C.

1 2 2 2 1 6 1 1

G.C. G.C.

BLACK TBD

G.C. OWNER (MODCLOTH)

BRASS FRAME

G.C.

WHITE METAL

G.C.

WHITE METAL

G.C.

WHITE

G.C.

WHITE

G.C.

TBD

G.C.

BRUSHED, POLSHED BRASS

G.C.

BLACK

G.C.

BRONZE

G.C.

DESCRIPTION BOH REFRIGERATOR

FINISH: WHITE METAL

7

BOH MOBILE SHELVING

1

BOH MOBILE SHELVING

1

FR SHELVING

1

RECESSED INTO WALL

1

LOCATED ON TELE/DATA BOARD

1

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS LOCATED BY MOPSINK

DIMENSION 20 5/8"W x 20 7/8"D x 32 3/4"H

MANUFACTURER DANBY

MODEL DCR044A2BDD

RESPONSIBILITY G.C.

QUANTITY NOTES / REMARKS 1 COORD. INSTALL WITH BOH SHELVING

QUANTITY NOTES / REMARKS 1 G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. 1 COORD. W/ MEP DWGS. GOLD POLISH FINISH 1 G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS.

PLUMBING SCHEDULE TAG PL.01

DESCRIPTION RESTROOM SINK

DIMENSION 20"W X 18"D

MANUFACTURER KOHLER

MODEL K-2084

RESPONSIBILITY G.C.

PL.02 PL.03

RESTROOM SINK FAUCET RESTROOM TOILET

2.2"W X 6.5"D X 6.5"H 17 5/8"W X 28 3/4"D X 30 3/4"H

MAC FAUCET KOHLER

FA444HD-17 CIMARRON K-3609

G.C. G.C.

PL.04 PL.05

SERVICE SINK SERVICE SINK FAUCET

21"W X 21 1/2"D X 44 1/2"H 8" SPREAD

TSA-1MOP B-0674-RGH

G.C. G.C.

PL.06 PL.07

WATER COOLER FLOOR DRAIN

TURBO AIR T&S BRASS AND BRONZE WORKS, INC. QUENCH MIFAB

750 F1100-2, (POLISHES BRASS TYPE 5 INCH ONLY)

G.C. G.C.

13 1/2"W x 14 1/2"D x 40 1/2"H 6"Ø STRAINER

1 1

FR 4

FR 5

08

09

A.04

4

4' - 6"

1' - 8"

MQ

CAB

F.03

14

COORD. W/ MEP DWGS. RECESS FLOOR DRAIN INTO FLOOR, G.C. TO TRENCH AS REQUIRED

SH.04

SH.03 LOCKER

EL 14

14

SH.01

SH.01

4' - 3 5/8"

14 1 14

F.01

CH-01

CH-01

F.24

11

11

F.24

HS

13

SH.01

SH.01 SH.01

2

PL.04 PL.05

12 UH

HS MQ

MQ

15' - 10 7/8"

1

FDSK

F.18

MQ

HS

CF

BACK OF HOUSE

SH.01

4

F.26

MQ

WC

5

REF

01 4' - 7"

13

6

CH-2 REF-2

1 HS

BS PL.06

SALES

4' - 0"

TDSH

9

F.23

MQ

DSK

10

A.06

F.18

F.04

KB

FB-01 F.12 ADA FR

11

2' - 8"

13

7

A.05

CH-01

F.02

STORAGE CLOSET

FACP

7

F.01

BY S&L DESIGN; FINISH MT-01 FINISH: MT-01, GL-01 FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS WD-01 FINISH: MT-01, WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01 FINISH: PT-01B; BUILT IN WINDOW DISPLAY (L-01) FINISH: MT-01 FINISH: MT-01, GL-03 FINISH: WD-01 G.C. TO COORD. INSTALLATION W/ BRAD JOBE; CURTAIN SUSPENDED FROM RODS AND RINGS

EQUIPMENT SCHEDULE TAG REF-2

9

F.25

1

1

7

FB-01

A.06

MQ

REFINISHED VINTAGE CHAIR NOT INSET; REMOVABLE AREA RUG COORD. INSTALL WITH BOH REFRIGERATOR (REF-2); REF. ELEVATIONS GRAY FINISH: MT-01; WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01; WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS

1

1 23 1

9

4

MQ

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS CEILING RECESSED MERCHANIDISING TRACKS; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND POWDERCOAT TO MATCH ADJ. FINISH COORD. W/ TELE/DATA BOARD G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS FINISH: WHITE METAL

19

WHITE

G.C.

1

4 2 1 1

TBD

BLACK

FINISH: WD-01 FINISH: WHITE METAL

1

BROWN-BLACK VIBRANT FRESH GOLD

THE CONTAINER STORE

2 2

1 2

IKEA KOHLER

VIDEO MOUNT PRODUCTS GATCO

FINISH: WHITE METAL

4

MQ

FINISH: WHITE METAL

1

FB-01

CH-01 A.06

F.21

OWNER (MODCLOH)

THE CONTAINER STORE THE CONTAINER STORE PIPP MOBILE STORAGE PIPP MOBILE STORAGE PIPP MOBILE STORAGE FAUCETSINHOME

WALL MOUNTED VENTILATED SHELF

WHITE METAL

2

F-01

MMF INDUSTRIES TBD REJUVENATION

SH16

G.C.

F.C. G.C. F.C. F.C. OWNER (MODCLOTH)

11.7"H x 7.9"W x 3.6"D 3/4 TORSO 24"W X 36"H 12"D (LENGTH VARIES)

WHITE METAL

WD-03/MT-01 CC0949 MT-01 BRASS/GLASS TBD

ARAKAWA

WALL MOUNTED VENTILATED SHELF

G.C.

TBD G.C. F.C. F.C. TBD BRAD JOBE

REF. PLANS; G.C. TO CUT LENGTHS IN FIELD AS REQ'D

SH12

TD

F.C. F.C. F.C. F.C.

WHITE METAL

CH-03

CPT-01

7' - 3 1/2"

F.18 F.20

FREE-STANDING HANG RACK GLASS FIXTURE ADA BENCH

19" H X 17" Ø -30" W X 26" D 116"W x 108"L 42"L x 24"D x 34"H

F.C.

3' - 1 1/4"

MQ MQ

4' - 9 3/8"

F.03 F.04 F.05 F.12

FITTING ROOM POUF EMPLOYEE CHAIR VINTAGE CHAIR AREA RUG WALL MOUNTED DESK

POLISHED BRASS

MIN

4

14

12

1

F.23

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

B16

F.C./G.C.

3' - 0"

HS

8' - 8"

EL F.01

THE CONTAINER STORE THE CONTAINER STORE THE CONTAINER STORE TBD THE CONTAINER STORE THE CONTAINER STORE - UMBRA THE CONTAINER STORE TBD TBD TBD TBD THE CONTAINER STORE ULINE F.C.

BRASS

SH.05

VESTIBULE

4' - 0"

12"

F.C.

03

F.20

4' - 6"

WALL MOUNTED SHELVING BRACKET

F.C.

POLISHED BRASS

A.01

CH-03 11

CB

7

1' - 7"

30" W X 78" H

F.C.

CH-03

CH-03

GB

9

FITTING ROOM LOUNGE

A.03

F.03

A.02

TELE/DATA

F.C.

POLISHED BRASS

8

7

PL.07

4

1' - 6"

30" W X 78" H

F.C./G.C.

MIN

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

2' - 0"

F.C.

BRASS

F.23

4

10

FB-01

2' - 0"

1"W X 1"H x 3"D

F.C./G.C.

MQ

FB-01

TD

TPH

4 F.27 3' - 0"

A.06

2' - 0"

F.C.

BRASS

02

13

A.06

MR

3' - 6"

F.C.

30" W X 78" H

B12

BR

11

3

PL.02

2' - 0"

78" W X 58" H

F.C./G.C.

QUANTITY NOTES / REMARKS 1 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 1 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 1 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 6 FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. 20 FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. 6 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 1 FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. 2 FINISH: WHITE METAL

CH-01

2' - 0"

F.C.

BRASS

RESPONSIBILITY

FB-01

CH-01

18' - 0"

FITTING ROOM HANG BAR SHORT

3

2' - 8"

A.07

FITTING ROOM MIRROR

1

4' - 2 5/8"

A.06

VALET PEG

46"W x 93"H x 2 1/2"D

FINISH

A.06

9

MIN.

A.05

FITTING ROOM HANG BAR

MANUFACTURER F.C.

LOUNGE

MQ

3' - 0"

A.04

LARGE MIRROR

F.05

MQ

DIMENSION 24" W X 78" H

CH-01

4

15' - 8"

A.03

3-WAY ARCHED MIRROR

07

PL.03 14

2' - 8"

A.02

06

ADA RESTROOM

12

HS

FIXTURE SCHEDULE DESCRIPTION FITTING ROOM LOUNGE MIRROR

FR 3

MEP ENGINEER:

MQ

TAG A.01

FR 2

1' - 10 3/4" 2' - 0"

X.01

ROOM TAG

1

STORAGE CLOSET

1' - 10 3/4"

01

4

FR 1

11

F.23

13

MQ

MQ

17' - 2 1/2"

13

F.23

11

8' - 1 5/8"

FIXTURE PLAN

STAMP HERE:

SCALE: 1/4" = 1'-0"

FIXTURE PLAN GENERAL NOTES:

FIXTURE PLAN KEY NOTES:

1. REFER TO FINISH SCHEDULE A-104 FOR FINISH DESCRIPTIONS AND SPECIFICATIONS.

1

LEASE LINE

2. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES.

2

NEW MOP SINK AND FAUCET; COORD. W/MEP DWGS.

3. G.C. & F.C. TO COORDINATE CONSTRUCTION & INSTALLATION MATERIALS, METHODS, AND SCHEDULING OF FIXTURES.

3

NEW RESTROOM TOILET AND SINK; COORD. W/MEP DWGS.

4

G.C. TO PROVIDE FIRE RATED PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND MILLWORK CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION.

4. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS. 5. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP. 6. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING. G.C. TO COORDINATE WITH SHOP DRAWINGS TO BE PROVIDED BY THE FIXTURE CONTRACTOR. 7. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS. 8. FINISHES TO BE FIRE RATED AS REQUIRED BY STATE/LOCAL BUILDING CODES. 9. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND MILLWORK. COORDINATE CONSTRUCTION DETAILS AND DIMENSIONS WITH FIXTURE PLANS AND FIXTURE SHOP DRAWINGS.

5

6

7 8

13. THERE ARE NO POINT-OF SALES OR SERVICE COUNTERS IN THIS STORE. MODCLOTH STORES ARE DESIGNED AND OPERATE AS SHOWROOMS. MO MERCHANDISE IS SOLD ON LOCATION.

DATE: 08/20/2018

NEW DRAPERY PANEL INSTALLED ON RODS AND RINGS AT FITTING ROOMS; B.O. OPENING TO THE PEAK OF ARCHED TRANSITION AT 8'-3" AFF; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS

CHECKED BY: JSP

3-WAY ARCHED MIRROR (A.02) W/ LIGHTING BEHIND MIRROR FRAME; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; F.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND RCP

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

MIRROR (A.01) W/ LIGHTING ON BOTH SIDES OF THE FRAME; B.O. FRAME MOUNTED @ 9" AFF; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; F.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS.

10

LARGE MIRROR (A.03) LOCATED IN LOUNGE; B.O. FRAME MOUNTED @ 9" AFF; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; F.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS.

11

MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD, REF. A-102B FOR DIMENSIONS; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.

12

NEW HIDDEN DOOR AND FRAME FURNISHED AND INSTALLED BY G.C.; ALL HARDWARE AND FRAMING TO BE CONCEALED FROM ENTRY SIDE OF DOOR; REF. DOOR DETAILS A-602

13

NEW STOREFRONT DISPLAY PLATFORM (F.23); FURNISHED AND INSTALLED BY G.C.; FINISH; PT-04 & L-01

14

NEW B.O.H. PIPP SHELVING; G.C. TO COORD. INSTALLATION W/ MANUFACTURER; G.C. TO VERIFY SITE DIMENSIONS AND SUBMIT A PROPOSED LAYOUT FROM FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION.

11. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS.

PROJECT NO.: 218231

NEW TELE/DATA BOARD BY G.C. (3/4" FRT PLYWOOD) MOUNTED TO WALL AT B.O.H. AND PAINTED TO MATCH ADJ. FINISH

9

10. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.

12. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES.

NEW B.O.H. CONTAINER STORE ELFA SHELVING; G.C. TO COORD. INSTALLATION W/ MANUFACTURER; G.C. TO VERIFY SITE DIMENSIONS AND SUBMIT A PROPOSED LAYOUT FROM THE CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT

FIXTURE PLAN

A-101.00 SHEET 9 OF 27


ARCHITECT OF RECORD:

HATCH & SYMBOL LEGEND HATCH / SYMBOL

FR 1

STORAGE CLOSET

MIRROR NICHE

FR 2

FR 3

ADA RESTROOM

02

04

05

9' - 0" AFF

06

07

11

10' - 0" AFF

9' - 0" AFF

12' - 10 3/4" AFF

GYP. CEILING

9' - 0" AFF

9' - 0" AFF

9' - 0" AFF

GYP. CEILING

GYP. CEILING

EX'G CEILING

PT-01C

GYP. CEILING

GYP. CEILING

GYP. CEILING

WC-03

PT-01C

PT-01C

PT-01C

PT-01C

PT-01C

DESCRIPTION

EXISTING PARTITION TO REMAIN

IN-CEILIGN FIRE RATED WOOD BLOCKING WHERE REQ'D

NEW PARTITION

LOUNGE CLG

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

11' - 0" AFF

ROOM NAME

GYP. CEILING

01

25

1

14

21

14

34

1

14

PT-01C

FINISH SYMBOL

DESCRIPTION

MANUFACTURER

SHOPPER TRACK W/ STEM KIT

TC1

SHOPPER TRACK - SECONDARY UNIT

MD

WIRELESS MOTION DETECTOR WIRELESS DOOR CONTACT

ST ST CLG

COORD. W/ VENDOR DWGS (ADT SECURITY)

WHITE

FIRE ALARM STROBE WALL MOUNTED

COORD. W/ APPROVED FIRE ALARM DWGS

FIRE ALARM STROBE CEILING MOUNTED

COORD. W/ APPROVED FIRE ALARM DWGS

WHITE WHITE

REF. APPROVED FIRE ALARM DWGS

WHITE

REF. APPROVED FIRE ALARM DWGS

1

S

WALL MOUNTED SPEAKER REF. ELEVATIONS FOR MOUNTING HEIGHT

COORD. W/ VENDOR DWGS (PLAYNETWORK)

WHITE

NOT USED

SMOKE DETECTOR

COORD. W/ MEP DWGS COORD. W/ MEP DWGS

WHITE

REF. MEP DWGS

CONCEALED SPRINKLER HEADS WITH COVER TO MATCH ADJACENT FINISH

COORD. W/ APPROVED SPRINKLER DWGS

WHITE

REF. SPRINKLER DWGS

MATCH ADJ. FINISH

COORD. W/ APPROVED SPRINKLER DWGS

HVAC RETURN GRILLE; SIZED AS PER MECHANICAL DWGS; PAINTED TO MATCH CLG COLOR

36

28

10

F-1

R-1

F-1 TYP. F-1

BRASS TRANSITION 23

R-1

R-1

COORD. W/ MECHANICAL DWGS

WIRELESS ACCESS POINT

COORD. W/ VENDOR DWGS (BANDWAVE)

ACCESS PANEL (G.C. TO MATCH REQ'D FIRE RATING)

MATCH ADJ. FINISH WHITE

P-5

26

LS

ACTIVAR MODEL TMW OR APPROVED EQUIVALENT; PAINT TO MATCH ADJACENT FINISH

MATCH ADJ. FINISH

COORD. W/ SIGNAGE SHOP DWGS

PER VENDOR

COORD. W/ MEP DWGS

GYP. CEILING

DC

R-6 WC-05

14 LS

19 6

R-3

R-3

CH-1

TYP.

17

12' - 10 3/4" AFF

21

EX'G GWB

EM-1 CLG CLG

J

TR-1 F-1

WINDOW DISPLAY

12' - 10 3/4" AFF

TYP. 10

HANGING SYSTEM - MERCHANDISING TRACK

ARAKAWA - CRB -1800A; (CRC-1800A ACCEPTABLE, IF NOT IN STOCK); MATCH ADJ. FINISH

DESCRIPTION CHANDELIER

REF. SHOP DWGS

GB HS

MODEL TBD

FINISH BRASS

W/V 100W

P-5

CHANDELIER

CH-3

DECORATIVE LIGHTING INSTALLATION

EM-1

SURFACE RECESSED EMERGENCY LIGHT

EX-1

EX-2

EX-3

F-1

RECESSED CEILING MOUNTED EXIT SIGN AT SALES

RECESSED WALL MOUNTED EXIT SIGN AT SALES WALL MOUNTED EXIT SIGN AT BOH

TBD

TBD

BRASS

100W

REF. MEP DWGS REF. A -101

TBD

TBD

BRASS

100W

10

EVENLIGHT-APERION

APR-25-LC-UI

WHITE

25W

5

CONTECH

REXA-SF-R-EM-C-P

WHITE

120/277 V

1

CHANDELIER PROVIDED BY OWNER (MODCLOTH); G.C TO PROVIDE LAMPS: (10) WARM WHITE (2700K) 9W LED A19 BULBS

CHANDELIER PROVIDED BY OWNER (MODCLOTH); G.C TO PROVIDE LAMPS: (10) WARM WHITE (2700K) 9W LED A19 BULBS G.C. TO PAINT TO MATCH ADJ. FINISH

X-RW-1-C-W

ENCORE

LSE-8-R-1

WHITE

WHITE

3

120/277 V

1

P-5

4

GYP. CEILING

21

PT-01C

FL-2

CLOSET

22

13 12' - 10 3/4" AFF

17

R-6

LS

21

EX-3

EX'G GWB

9

PT-01C

TYP.

WC-07

P-5

LS

TRANSITION

25

7' - 6" AFF

TYP.

GWB. PT-01C

R-3

ADA FR

20

10

TYP. 3' - 3"

3' - 3"

FL-1

EM-1

9' - 0" AFF GYP. CEILING

15

R-1 J 35

R-3

CLG

16

PT-01C

16

09

AHU

R-3

9' - 0" AFF R-1

GYP. CEILING

R-1 15

F-1 36 21

GYP CEILING

18

LIGHT COVE

13' - 1 1/4" AFF GYP. GWB PT-01C

22 13

R-3

1

21

R-3

BOH

FL-1 EM

TYP.

14 FL-1

TYP.

12' - 10 3/4" AFF

F-1 D D

F-1 LS

F-1

EX'G GWB CLG CLG

7

36

TYP.

TC2

21

CLG

TYP.

14

PT-01A

3

WH 14

F-1

CLG

F-1 TR-1

GB CLG

CLG

F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1

F-1

J

CLG

F-1 F-1 TR-1 1

NO HARD CONNECTION TO LL'S SLAB OR ACOUSTIC CEILING. ANY PENETRATION MADE TO ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATION AND SEAL WITH FLEXIBLE CAULK TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS PANEL REQUIRED IN ADDITION TO THE ACCESS PANEL ALLOCATED IN SPACE, G.C. IS TO MAKE THE CONNECTION AND THEN PATCH BACK IN WITH TWO LAYERS OF THE TYPE'X' GYP. BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING

R-3

PT-01C

2

20

TYP.

R-3

FR 5

1

S

CLG

CLG

14

CLG GB

CLG

J

F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 TR-1

12

10 TYP.

GB

CLG

J F-1 TR-1

CLGCLG

F-1

F-1 7

27

REFLECTED CEILING PLAN

STAMP HERE:

SCALE: 1/4" = 1'-0"

SINGLE FACE, RECESSED CEILING MOUNTED

REFLECTED CEILING PLAN GENERAL NOTES: ENCORE - SUPER UNIVERSAL

14

TYP.

R-1

S

R-3

01

QUANTITY COMMENTS 1 CHANDELIER PROVIDED BY OWNER (MODCLOTH); G.C TO PROVIDE LAMPS: (10) WARM WHITE (2700K) 9W LED A19 BULBS

1

OS

TYP.

18

FL-1 EM

R-3

TYP.

F-1 F-1

GENERAL FINISH/FIXTURE NOTES CH-2

17

19

FL-1

19

SALES

PT-01C MANUFACTURER TBD

TYP.

38

F-1

LIGHTING SCHEDULE TAG CH-1

9' - 0" AFF

26

TYP.

12

39

R-2

PT-01C

1

POWER COAT TO MATCH ADJ. FINISH

EX-2

R-6

11' - 0" AFF

HS

VESTIBULE

4

5

TYP.

J 35

24

CLG

WC-06

(PLASTER)

PL-01

16

5 4

21

TC1

EX-1

AS REQ'D

BORDER: 22; FINISH: 26

P-5

11

CLG

8 DC

EX'G GWB

29

TYP.

36

9' - 0" AFF

1

P-5

14

PT-01C

REF. MEP DWGS

TYP.

GYP. CEILING

21

CH-3

CH-3

5

4

CLG

08

REF. MEP DWGS

P-5

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

ARCHED FR TRANS TYP.

TYP.

EM-1 P-5

24

7' - 6" AFF

22

P-5

EX-2 MD CLG

TYP.

CLG

TYP.

BRASS

REF. SPRINKLER DWGS

MATCH ADJ. FINISH

29

EM-1

BRASS

CH-3

LS

R-1

F-1 TR-1

17

19 TYP.

CH-3

19 R-5

R-5

23

5

S

CLG

R-1

19

P-6

R-6

P-5

4

TYP.

37

TL-1

F-1

S

26

CH-2

TYP.

EM-1 EX-2

32

37

4

19

16

R-1

32

LS WC-04

17

29

CH-3 28

LS

R-1

12

P-5

4

S1 J

5

R-6 P-5

P-5

36

35

CLG

LS WC-03 R-6

P-5

5

R-1

S1

4

FL-1

R-1

17

TYP.

LS

PT-01C

NOT USED

HVAC SUPPLY GRILLE; SIZED AS PER MECHANICAL DWGS; PAINTED TO MATCH ADJ COLOR

1" TAPED-IN LINEAR SLOT DIFFUSER

R-6

ENTRY

UPRIGHT SPRINKLER HEADS

LS

R-6

33

GB

BRASS

REF. MEP DWGS

WHITE

R-6 4

14 R-1

7

9' - 0" AFF

9' - 0" AFF

TYP.

P-5 21

F-1

TRANSITION

R-6

FR 4

OCCUPANCY SENSOR CEILING MOUNTED

REMOTE DRIVER FOR STOREFRONT SIGNAGE

TYP.R-6

R-1

HS

PT-01A

REF. APPROVED FIRE ALARM DWGS

WHITE

36

CLG

F-1

GYP. CEILING

REF. APPROVED FIRE ALARM DWGS

WHITE

D

F-1

J

(CURVED) 12' - 10 3/4" AFF

5

COORD. W/ VENDOR DWGS (PLAYNETWORK)

WA

PT-01C

03

1 PAIR

CEILING RECESSED SPEAKER

OS

F-1

FR LOUNGE DOME

1

S

SD

EXG' GWB

31

P-5

P-5 LS WC-02

WC-01

CLG

F-1

1

PAINT TO MATCH ADJ. FINISH

COORD. W/ APPROVED FIRE ALARM DWGS

TR-1

1

WHITE

COORD. W/ APPROVED FIRE ALARM DWGS

FIRE ALARM SPEAKER/STROBE CEILING MOUNTED W/ STEM KIT

S

WHITE

COORD. W/ VENDOR DWGS (ADT SECURITY)

FIRE ALARM SPEAKER/STROBE WALL MOUNTED

CLG

COORD. W/ VENDOR DWGS (RETAIL NEXT)

12' - 10 3/4" AFF QUANTITY

WHITE

COORD. W/ VENDOR DWGS (ADT SECURITY)

SURFACE MOUNTED SECURITY CAMERA; REF. ELEVATIONS FOR MOUNTING HEIGHT S

FINISH

COORD. W/ VENDOR DWGS (RETAIL NEXT)

TC2

DC

LS

WINDOW DISPLAY

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

REFLECTED CEILING FINISH TAG

CEILING TYPE

MEP ENGINEER:

FACP

0' - 0" AFF

SYMBOL

LOUNGE DROP CLG

SINGLE FACE, RECESSED WALL MOUNTED

SINGLE FACE, WALL MOUNTED @ 9'-0" AFF

REFLECTED CEILING PLAN KEY NOTES:

1. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT UNLESS OTHERWISE NOTED.

1

LEASE LINE

19

NEW CONCEALED SPRINKLER HEAD AT GWB CEILINGS, TYP.; REF. MEP AND APPROVED SPRINKLER DWGS; FINISH WHITE.

2. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SUBMIT PLANS FOR MODIFICATION OF THE FIRE SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE THE TENANT SPACE. SUBMIT SHOP DRAWINGS TO THE LANDLORD, OWNER, AND ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL.

2

EXISTING AHU TO REMAIN; COORD. W/ MEP DWGS.

20

NEW UPRIGHT SPRINKLER HEAD AT OPEN CEILING LOCATIONS, TYP.; COORD. W/ MEP AND APPROVED SPRINKLER DWGS.

3

NEW SHELF MOUNTED WATER HEATER TO BE LOCATED ABOVE MOP SINK; B.O. SHELF AT 7'-6" AFF

21

EXISTING LANDLORD ACOUSTIC RATED CEILING ABOVE TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION; ANY DAMAGE CAUSED IN THE COURSE OF CONSTRUCTION IS TO BE PATCHED AND REPAIRED TO A 'LIKE NEW' CONDITION

3. ALL FINISHING AND PAINTING REQUIREMENTS SHALL BE AS PER THE FINISH SCHEDULE, INTERIOR ELEVATIONS, AND SPECIFICATIONS.

4

NEW LED STICK LIGHTING (TBD); INSTALL ON EACH SIDE OF MIRROR OF FITTING ROOM; FINISH HOUSING FOR LAMPING IN WHITE; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH.

22

PROVIDE TRANSFER GRILLE ABOVE CEILING; REF. MEP DWGS. FOR COORD.

NEW DRAPERY PANEL INSTALLED ON TAPED-IN RECESSED CURTAIN TRACK AT FITTING ROOM OPENING; B.O. OPENING AT 7'-0" AFF; FINISH TRACK WHITE; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS

23

EXHAUST FAN AND GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR

24

NEW SUPPLY GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR. G.C TO PROVIDE 12" X 12" RATED ACCESS PANEL IN EXISTING CEILING OPENING ABOVE IF REQ'D AS WELL AS 24" X 24" ACCESS PANEL AT LOWER 11'-0" LOUNGE CEILING; COORD. EXACT LOCATION W/ MEP DWGS

DATE: 08/20/2018 DRAWN BY: GR, RE, NK

MINI HORIZONTAL TRACK LIGHT FIXTURE 4' SUSPENDED LINEAR LED

AMERLUX-HORNET HIGH POWER MERCURY LIGHTING

HORNET-HP-H-A14-18-LED-WT-TJ1120-SP-3000-97 LSA-4-4000-35K-HTA-U55-UNI

WHITE

18W

45

GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY

WHITE

34W

5

SUSPENDED FROM CEILING/DECK ABOVE @ 11'-0" AFF

4. ALL LIGHT FIXTURES, INCLUDING EXIT LIGHTS, EMERGENCY LIGHTS, ETC., SHALL BE FURNISHED BY OWNER AND INSTALLED BY THE CONTRACTOR, EXCEPT THE G.C. SHALL PROVIDE AND INSTALL THE LAMPS FOR THE SM-1 AND P-1 FIXTURES.

5

FL-1 EM

4' SUSPENDED LINEAR LED EMERGENCY

MERCURY LIGHTING

LSA-4-4000-35K-HTA-U55-UNI-EM10BSL3102W

WHITE

34W

2

SUSPENDED FROM CEILING/DECK ABOVE @ 11'-0" AFF

5. THE CONTRACTOR SHALL USE A LASER LEVELING DEVICE FOR THE LEVELING OF ALL SOFFITS, CEILINGS, AND SUSPENDED GRIDS, TYPICAL.

6

G.C TO PROVIDE PRICING TO DEMOLISH AND RE-BUILD EXIST, 2HR RATED ACOUSTIC CEILING AS REQ'D FOR NEW WORK SCOPE

25

FL-2

SURFACE MOUNTED LINEAR LED

MERCURY LIGHTING

LSA-4-4000-35K-HTA-U55-UNI

WHITE

34W

1

CEILING SURFACE MOUNTED

6. THE ELECTRICAL CONTRACTOR IS TO VERIFY THAT THE EXISTING SERVICE IS ADEQUATE FOR THE DESIGN LOADS. IF NOT, NOTIFY THE ARCHITECT AND MEP ENGINEER IMMEDIATELY.

7

HS - MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD, REF. A-102B FOR DIMENSIONS; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.

26

EXIT SIGNAGE; RECESSED WALL MOUNTED; COORD. W/ ELEVATIONS

27

MODCLOTH CORNER NON-ILLUMINATED BLADE SIGN

28

NEW WALL MOUNTED SPEAKERS; G.C TO PROVIDE CONDUIT AND PULL STRING; COORD. W/ VENDOR

#

ISSUE

DATE

29

LIGHT FIXTURE TBD,G.C PROVIDE 10 LED 9W LED A19 LAMPS

1

ISSUE FOR PERMIT

09/07/2018

30

NEW CURVED DOME CLG; REF. CLG DETAILS A-501 AND BUILDING SECTIONS

31

NEW DROP CLG; REF. CLG DETAILS A-501 AND BUILDING SECTIONS

FL-1

P-5

LED STICK LIGHTING

P-6

VANITY LIGHTING

R-1

R-2

R-3

R-5 R-6

TL-1 TR-1

SEMI-RECESSED LIGHT WITH 1-TRACK HEAD

SEMI-RECESSED LIGHT WITH 2-TRACK HEADS

SEMI-RECESSED LIGHT WITH 3-TRACK HEADS

3"Ø DIMMABLE LED RECESSED DOWNLIGHT 3"Ø DIMMABLE LED RECESSED ROUND DOWNLIGHT WITH TRIMLESS FLANGE LED TAPE LIGHTING SURFACE MOUNTED LIGHT TRACK

HERA TBD AMERLUX-HORNET HIGH POWER

AMERLUX-HORNET HIGH POWER

AMERLUX-HORNET HIGH POWER

STICK3/46/WW, STICK3/24/WW, STICK3/8/WW TBD HORNET-HP-R/SR-FRAME-1-LED-12 0/ HORNET-HP-R-TRIM-A14-2-18-LEDWT-120-277-MFL-WT-3000-97 HORNET-HP-R/SR-FRAME-2-LED-12 0 / HORNET -HP-SR-TRIM-A14-2-18-LED-WT-120277-MFL-MFL-WT-3000-97 HORNET-HP-R/SR-FRAME-3-LED-12 0 / HORNET -HP-SR-TRIM-A14-3-18-LED-WT-120277-MFL-MFL-MFL-WT-3000-97

WHITE

50W/MIRROR

BRASS

(3) 8 W LED LAMPS 18W

WHITE

08 16 1 15

INSTALL 2 STICK LED ON EITHER SIDE OF MIRROR; 50W PER MIRROR ABOVE RESTROOM MIRROR

9. WHITE

18W

1

SEMI-RECESSED CEILING MOUNTED

10.

ALL VENDORS TO BE COORD. BY G.C.

8

NEW EXIT SIGNAGE: RECESSED CEILING MOUNTED; COORD. W/ ELEVATIONS.

9

NEW EXIT SIGNAGE: SURFACE WALL MOUNTED; COORD. W/ ELEVATIONS.

10

SURFACE MOUNTED TRACK LIGHTING IN LIGHT COVE; FINISH WHITE; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE; REF. A-501 FOR CONSTRUCTION DETAILS; COORD. W/ MEP DWGS.

KEEP ALL NEW COMPONENTS MOUNTED AS HIGH AS POSSIBLE IN EXPOSED CEILING

PROJECT NO.: 218231

CHECKED BY: JSP AREA: 1807 SQ.FT

ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT 11. CONCEALED WHERE POSSIBLE.

11

SUSPENDED CHANDELIER TBD, MOUNT B.O. CHANDELIER @ 8'-8", VERIFY IN FIELD; G.C. TO PROVIDE LED A19- 9W BULBS; 2700K

32

NEW CONCEALED CONTINUOUS 1" TAPED-IN LINEAR SLOT DIFFUSER AT WALL ABOVE DROP CEILING; COORD. W/ MEP DWGS, TYP.

12

ILLUMINATED MODCLOTH SIGNAGE; COORD. W/ MEP DWGS & SIGNAGE VENDOR; G.C. TO COORD. AND SUPERVISE INSTALL. SIGNAGE FILED UNDER SEPARATE PERMIT.

33

SUSPENDED CHANDELIER TBD, MOUNT B.O. CHANDELIER @ 8'-8", VERIFY IN FIELD; G.C. TO PROVIDE FROSTED G16 60W INCANDESCENT LAMPS; 2700K

WHITE

ACCESS PANELS IN CEILING MUST BE LOCATED TO PROVIDE ACCESS TO LANDLORD'S MECHANICAL 12. EQUIPMENT PER LOCAL GENERAL GROWTH AUTHORITY. G.C TO PROVIDE ACCESS PANELS AT ALL REQUIRED OLCATIONS

13

G.C. TO PROVIDE 12" x 12" ACCESS PANEL AT CEILING NEAR STOREFRONT WINDOW DISPLAY (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR SIGNAGE DRIVER ACCESS, COORD. EXACT LOCATION W/ MEP DWGS AND SIGNAGE VENDOR.

34

LIGHT FIXTURE TBD; CENTERED ABOVE MIRROR @ 7' - 0" AFF; REF. ELEVATIONS

13. SPRINKLER HEADS AT GYPSUM BOARD CEILING MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING TILES WHERE APPLICABLE

35

CEILING JBOX FOR FUTURE ILLUMINATED NEON SIGNAGE PROVIDED BY MODCLOTH

14

CONTINUOUS 1" TAPED-IN LINEAR SLOT DIFFUSER; COORD. W/ MEP DWGS, TYP.

36

IN-CEILING F.R. BLOCKING LOCATED FOR DECORATIVE SCREEN MOUNTING AND NEON SIGNAGE

15

EXISTING SUPPLY GRILLE; G.C. TO PAINT TO MATCH ADJ FINISH; COORD. W/ MEP DWGS, TYP.

37

LED TAPE LIGHTING IN COVE CONTINUOUS

16

NEW CEILING RECESSED SPEAKERS; G.C. TO PROVIDE CONDUIT AND PULL STRING, COORD W/ VENDOR

38

G.C. TO PROVIDE 18" x 18" ACCESS PANEL AT CEILING NEAR STOREFRONT ENTRY (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR DUCT HEATER, COORD. EXACT LOCATION W/ MEP DWGS AND SIGNAGE VENDOR

17

NEW GWB CEILING @ SALES AREA, FITTING ROOMS, AND WINDOW DISPLAY LOCATIONS, TYP.

39

G.C. TO PROVIDE 12" x 12" RATED ACCESS PANEL IN EXISTING CEILING OPENING IF REQ'D; G.C. TO PATCH OPENINGS TO MATCH CURRENT CEILING FIRE AND ACOUSTIC RATING

WHITE 18W

11

SEMI-RECESSED LIGHT WITH 3-TRACK HEADS

XR3NC-D-XM20-30K-1450-WH

WHITE

17W

2

RESTROOM LIGHTING

SOLAIS LIGHTING

XR3NC-D-XM20-30K-1450-WH/TR

WHITE

17W

11

FITTING ROOM LIGHTING

CONTECH

TLT12V327K12R

WHITE

12W

1

REF. ARCHITECTURAL CEILING DETAILS FOR MOUNTING IN COVE CEILING SURFACE MOUNTED TRACK; G.C. TO CUT LENGTHS PER RCP.

LT-P

8. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTS; ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIELD FIRE INSPECTOR AT THE TIME OF THE FINAL BUILDING INSPECTION.

SEMI-RECESSED CEILING MOUNTED

SOLAIS LIGHTING

CONTECH

7. ENSURE THAT ALL EQUIPMENT INCLUDES / BARES UL LABELS.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

WHITE

120 V

7

18

AREA OPEN TO EXISTING ACOUSTIC CEILING ABOVE

REFLECTED CEILING PLAN

A-102.00 SHEET 10 OF 27


ARCHITECT OF RECORD:

HATCH & SYMBOL LEGEND HATCH / SYMBOL

DESCRIPTION 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

EXISTING PARTITION TO REMAIN

NEW PARTITION

1' - 2"

ROOM NAME

11

FR 1

STORAGE CLOSET

FR 2

FR 3

ADA RESTROOM

04

05

06

07

11

10' - 7"

1

ROOM TAG

26

WIRELESS DOOR CONTACT

DC

COORD. W/ VENDOR DWGS (ADT SECURITY) COORD. W/ VENDOR DWGS (ADT SECURITY)

WHITE BLACK

1

24

1 PAIR

31

S1

COORD. W/ VENDOR DWGS (ADT SECURITY)

PAINT TO MATCH ADJ. FINISH

S

FIRE ALARM SPEAKER/STROBE WALL MOUNTED

COORD. W/ APPROVED FIRE ALARM DWGS

WHITE

REF. APPROVED FIRE ALARM DWGS

S

FIRE ALARM SPEAKER/STROBE CEILING MOUNTED W/ STEM KIT

BLACK

REF. APPROVED FIRE ALARM DWGS

CLG

ST

GB

S1

FIRE ALARM STROBE CEILING MOUNTED

COORD. W/ APPROVED FIRE ALARM DWGS

WHITE

2

WALL MOUNTED SPEAKER REF. ELEVATIONS FOR MOUNTING HEIGHT

COORD. W/ VENDOR DWGS (PLAYNETWORK)

WHITE

4

WHITE

1' - 2" 10

COORD. W/ SIGNAGE SHOP DWGS

WHITE PER VENDOR

12

23

@ 34" AFF

CLG

FR 4

FR 5

17

WA

10

DC

26

CLG

31

TC1

5

1

2

31

COORD. W/ VENDOR DWGS (ADT SECURITY)

WHITE

1

12

KP

ALARM KEY PAD; MTD @ 48" MAX.

COORD. W/ VENDOR DWGS (ADT SECURITY)

WHITE

1

16

CP

ALARM CONTROL PANEL; FINISH WHITE

COORD. W/ VENDOR DWGS (ADT SECURITY)

PER VENDOR

1

CG

ALARM CELLGUARD

COORD. W/ VENDOR DWGS (ADT SECURITY)

PER VENDOR

1

NM

ALARM VIDEO RECORDER / MONITOR

COORD. W/ VENDOR DWGS (ADT SECURITY)

PER VENDOR

1

AV

AUDIO / VISUAL CONTROL BOX

COORD. W/ VENDOR DWGS (PLAYNETWORK)

PER VENDOR

1

V

VOLUME CONTROLS, MTD @ 48" AFF MAX.

COORD. W/ VENDOR DWGS (PLAYNETWORK)

WHITE

1

WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE, MTD. 18"AFF U.N.O.

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

DEDICATED WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE, MTD. 18"AFF U.N.O.

COORD. W/ ELECTRICAL DWGS

WALL MOUNTED GROUNDED 20A QUAD RECEPTACLE, MTD. 18"AFF U.N.O.

COORD. W/ ELECTRICAL DWGS

CLG CLG

GB J

1' - 5"

@ 34" AFF

2' - 6"

SALES

01

11

M

D

6"

D D DDDDD D

11

T

6

@ 93" AFF @ 93" AFF @ 93" AFF @ 93" AFF @ 15" AFF

14

BACK OF HOUSE

3

@ 48" AFF

8

ST

7

16

3 7/8"

ALARM SIREN

W

J CLG

28 @ 15" AFF @ 15" AFF

OS

5

11

21

13

31

CLG

33

1

REF. SHOP DWGS

25

12

OS

W

5

9"

ADA FR

10

1

32

VESTIBULE S TS

MD CLG

33

35

WHITE

13

31

09

W

REF. MEP DWGS

STORAGE CLOSET

30

08

CLG

COORD. W/ VENDOR DWGS (BANDWAVE)

AS

S

CLG

ST

20

10

WIRELESS ACCESS POINT

WA

5"

DC

COORD. W/ MEP DWGS

16

J

CLG

34

5 3/4"

REMOTE DRIVER FOR STOREFRONT SIGNAGE

D

COORD. W/ MEP DWGS

EQ S

REF. APPROVED FIRE ALARM DWGS

COORD. W/ VENDOR DWGS (PLAYNETWORK)

OCCUPANCY SENSOR CEILING MOUNTED

OS

WHITE

S

34

REF. APPROVED FIRE ALARM DWGS

CEILING RECESSED SPEAKER

SMOKE DETECTOR

SD

WHITE

27

EQ

ST

S

COORD. W/ APPROVED FIRE ALARM DWGS

ST

30 31

EQ

F

CLG

FIRE ALARM STROBE WALL MOUNTED

S1

8

OS

5 W

J

5

5 3/4"

ST

COORD. W/ APPROVED FIRE ALARM DWGS

31

03

16

CLG

SURFACE MOUNTED SECURITY CAMERA; REF. ELEVATIONS FOR MOUNTING HEIGHT

30

FITTING ROOM LOUNGE

4 30

WIRELESS MOTION DETECTOR

MD

32

W

02

14

19

1

S

24 29

10

16

31

31 J

S

34

10

29

S

CLG

CLG

CLG

6' - 0"

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O. WHITE, U.N.O.

HUBBLE CFB4G30RCR W/ 8"Ø = BRASS FLUSH COVER PLATE CFBS1R8CVRBRS; NOTE: COVER MUST ALIGN WITH FINISH FLOOR

BRASS

REF. ELECTRICAL DWGS

DATA/FAX MODEM RECEPTACLE ON DEDICATED CIRCUIT

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

LOW VOLTAGE STUB-UP; COORD. W/ A/V VENDOR (PLAYNETWORK)

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

WHIP CONNECTION

COORD. W/ ELECTRICAL DWGS

G.C. TO PAINT EXPOSED WHIP TO MATCH ADJACENT FINISH

REF. ELECTRICAL DWGS

SWITCH

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

SWITCH / OCCUPANCY SENSOR COMBINATION

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

DIMMER SWITCH

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

MASTER OVERRIDE SWITCH

COORD. W/ ELECTRICAL DWGS

WHITE, U.N.O.

REF. ELECTRICAL DWGS

J

CONCEALED IN-WALL JUNCTION BOX

COORD. W/ ELECTRICAL DWGS

N/A

REF. ELECTRICAL DWGS

J

CONCEALED IN-CEILING JUNCTION BOX

COORD. W/ ELECTRICAL DWGS

N/A

REF. ELECTRICAL DWGS

MULTI-CHANNEL 24/7 PROGRAMMABLE TIME-CLOCK

COORD. W/ ELECTRICAL DWGS

WHITE

REF. ELECTRICAL DWGS

CLG TM

T TS GB

F

6' - 5"

PROGRAMMABLE THERMOSTAT FINISH WHITE; MTD @ 48" AFF MAX.

COORD. W/ ELECTRICAL DWGS

TEMPERATURE SENSOR; FLUSH BUTTON TYPE

COORD. W/ ELECTRICAL DWGS

WHITE WHITE

WIRELESS GLASS BREAK

COORD. W/ ELECTRICAL DWGS

WHITE

FIRE PULL TO BE RELOCATED

COORD. W/ ELECTRICAL DWGS

RED

1' - 0"

TC2

10

31

12

CLG

5 3/4"

10

GB CLG

CLG

24

DEDICATED 4-GANG FLUSH FLOOR BOX; PROVIDE (3) GROUNDED 20A DUPLEX RECEPTACLES AND (1) TELE/DATA OUTLET

M

CLG CLG

22

J

CLG GB

CLG

26

25

31

31

@ 34" AFF

10

CLG

GB

J

@ 34" AFF

CLG

J CLGCLG

REF. ELECTRICAL DWGS REF. ELECTRICAL DWGS

D

D D

REF. ELECTRICAL DWGS

WHITE, U.N.O.

OS

10

17

CLG

COORD. W/ ELECTRICAL DWGS

W

EQ EQ

REF. ELECTRICAL DWGS

FLUSH CEILING MOUNTED GROUNDED 20A DUPLEX RECEPTACLE

CLG

ST

15

EQ EQ

DEDICATED WALL MOUNTED GROUNDED 20A QUAD RECEPTACLE, MTD. 18"AFF U.N.O.

WHITE, U.N.O.

33

1' - 4"

GFI

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

1

FACP

WHITE

V

COORD. W/ VENDOR DWGS (RETAIL NEXT)

AS

SHOPPER TRACK - SECONDARY UNIT

5

AV

TC2

5

5

LOUNGE

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

NM

1

9

4' - 9"

WHITE

TM

COORD. W/ VENDOR DWGS (RETAIL NEXT)

4' - 7"

SHOPPER TRACK W/ STEM KIT

31

W

2' - 0 5/8"

TC1

10

W

CP

QUANTITY

EQ

FINISH

EQ

MANUFACTURER

2' - 0 5/8"

DESCRIPTION

9' - 6 1/2"

SYMBOL

W

CG

@ 34" AFF

16

GFI @ 48" AFF

KP

J

2' - 5 5/8"

12

CLG

1' - 8"

5 3/4"

CLG

2' - 5 5/8"

MEP ENGINEER:

2' - 5 5/8"

01

REF. ELECTRICAL DWGS REF. ELECTRICAL DWGS 5 1 EXISTING

18

16

12

24

1

16

24

16

1' - 5"

1

POWER & SIGNAL PLAN

STAMP HERE:

SCALE: 1/4" = 1'-0"

POWER & SIGNAL PLAN GENERAL NOTES:

POWER & SIGNAL PLAN KEY NOTES:

1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED ON THIS PLAN AND ELEVATIONS. COORDINATED W/ THE FIXTURE PLAN ANY DISCREPANCIES REGARDING THE LOCATION(S) SHOWN HERE AND THE FIELD VERIFIED OR EXISTING CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT PRIOR TO COMMENCING THE WORK AFFECTED.

1

LEASE LINE

2

RELOCATED ELECTRICAL PANEL; COORD. W/ MEP DWGS

3

MULTI-CHANNEL 24/7 PROGRAMMABLE TIME CLOCK; COORD. W/ MEP DWGS.

2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE ELECTRICAL CODE, NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE COMPANY, AND ALL AUTHORITIES HAVING JURISDICTION.

4

21

SHOPPER TRACK TRAFFIC COUNTER SURFACE MTD; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE

22

SHOPPER TRACK TRAFFIC COUNTER SECONDARY UNIT WHITE SURFACE MTD; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE

NEW WHIP FOR LIGHT FIXTURE(TBD); CENTER ON MIRROR @ (TBD); REF. ELEVATIONS; FINISH TBD

23

WIRELESS MOTION DETECTOR; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)

5

NEW WHIP FOR LGHT FIXTURE(TBD); CENTER ON MIRROR @ (TBD); REF. ELEVATIONS; FINISH (TBD)

24

WIRELESS GLASS BREAK; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)

3. U.N.O. , ALL COVERPLATES AND DEVICES ( ELECTRICAL, SWITCHES, RECEPTACLES, COVER PLATES), SHALL HAVE FINISH COLOR TO MATCH ADJACENT FINISH COLOR.

6

SWITCH BANK; FINISH FOR ALL SWITCHES TO BE WHITE; ALL SWITCHES MTD. @ 48" AFF MAX, TYP.; ALL LIGHTING OTHER THAN BOH, EXTERIOR SIGNAGE, AND VESTIBULE IS TO BE DIMMABLE

25

4. ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH (2) PULL STRINGS BACK TO THE TELEPHONE EQUIPMENT.

7

MASTER OVERRIDE SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.

WALL MOUNTED CAMERA; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ SECURITY VENDOR (ADT); G.C. TO PAINT HOUSING TO MATCH ADJ. SURFACE; REF. ELEVATIONS FOR MOUNTING LOCATIONS

8

OCCUPANCY SENSOR COMBINATION SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.

9

WALL MOUNTED G.F.I. DUPLEX RECEPTACLE; FINISH WHITE; VERIFY EXACT LOCATION IN FIELD; COORD. W/ MEP DWGS.

10

WALL MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O.

5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALL CHASES IN THE FLOOR, WALLS, AND CEILING SURFACES AND MATERIALS AS REQUIRED. 6. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED SHALL BE PATCHED FLUSH WITH ADJACENT WALL SURFACES. 7. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL NOT EXCEED 6". 8. PROVIDE A MINIMUM OF 10% SPACE CIRCUITS IN EXISTING ELECTRICAL PANEL(S) PROVIDE BREAKER LOCKOUTS FOR VAV UNITS AND SEPARATE CIRCUIT OUTLINES AT TELEPHONE EQUIPMENT. 9. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM LOCATION AND REQUIREMENTS. 10. ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT CONCEALED WHERE POSSIBLE.

11

WALL MOUNTED DEDICATED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O.

12

CEILING MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" MAX. FROM GLAZING TYP.

13

MOUNT (2) QUAD RECEPTACLES AND (1) TELE/DATA OUTLET @ 93" AFF ABOVE TELE/DATA BOARD, AND (1) QUAD RECEPTACLE @ 15" MIN. AFF BELOW TELE/DATA BOARD. REF. ELEVATIONS

14

PROVIDE (1) LOW VOLTAGE STUB UP @ 15" MIN. AFF BELOW TELE/DATA BOARD AND (1) LOW VOLTAGE STUB UP @ 93" AFF ABOVE TABLE. REF. ELEVATIONS

15

DEDICATED 4-GANG FLUSH FLOOR BOX UNDER CONSULTATION TABLE: HUBBLE CFB4G30RCR W/ 8"Ø BRASS FLUSH COVER PLATE CFBS1R8CVRBRS; G.C. INSTALL BEFORE SLAB IS POURED, REF. A-104 FINISH PLAN

DATE: 08/20/2018

27

SECURITY KEYPAD; FINISH WHITE; MTD. @ 48" AFF MAX; G.C. TO COORD. INSTALL W/ SECURITY VENDOR (ADT)

CHECKED BY: JSP

28

VOLUME CONTROL; FINISH WHITE MOUNTED @ 48" AFF MAX. ONTO TELE/DATA BOARD; REF. ELEVATIONS FOR MOUNTING LOCATION; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK)

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

29

RECESSED CEILING MOUNTED SPEAKER; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH WHITE

30

WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX, MOUNTED; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; REF. ELEVATIONS FOR MOUNTING LOCATIONS

31

RUN ALL AV/DATA AND LOW VOLTAGE VENDORS TO B.O.H.; G.C. TO PROVIDE CONDUIT AND PULL STRING FOR ALL.

32

WALL MOUNTED FIRE ALARM STROBE; FINISH WHITE; COORD. W/ MEP & APPROVED FIRE ALARM DWGS

CONCEALED MOUNTED J-BOX FOR TRACK LIGHTING AND LIGHTING ABOVE; COORD. W/ MEP DWGS

33

RELOCATED WALL MOUNTED FIRE ALARM STROBE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM

17

CONCEALED REMOTE DRIVER FOR NEW ILLUMINATED STOREFRONT SIGNAGE AND BLADE SIGN

34

18

SURFACE MOUNTED DUPLEX RECEPTACLE 5325-W ON DISPLAY PLATFORM; FINISH TO MATCH ADJ. SURFACE

CELING MOUNTED FIRE ALARM SPEAKER/STROBE; FINISH WHITE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS

35

FIRE PULL AND KEYPAD; GC TO CONCEAL WIRING IN-WAL

EXISITING PRAGRAMMABLE THERMOSTAT TO REMAIN; COORD. W/ MEP DWGS.

20

FLUSH WHITE BUTTON TYPE TEMPERATURE SENSOR; COORD. W/ MEP DWGS.

PROJECT NO.: 218231

CEILING MOUNTED CAMERA; G.C. TO PROVIDE CONDUIT & PULL STRINGS; COORD. INSTALL W/SECURITY VENDOR (ADT); G.C. TO PAINT HOUSING TO MATCH ADJ SURFACE.

26

16

19

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT

POWER AND SIGNAL PLAN

A-103.00 SHEET 11 OF 27


HATCH & SYMBOL LEGEND DESCRIPTION

EXISTING PARTITION TO REMAIN

NEW PARTITION

2

2

NEW CONCRETE TOPPING; C-01 RAISED CONCRETE SLAB; C-02

LOUNGE

FITTING ROOM LOUNGE

FITTING ROOMS

STORAGE CLOSET

RESTROOM

02

03

04 & 06-10

05

11

PT-01

WALL

PT-01

WALL

PT-01

WALL

PT-01

WALL

T-02/PT-01

BASE

B-01

BASE

B-01

BASE

B-01

BASE

B-01

BASE

B-03

FLOOR

WF-01B

FLOOR

WF-01B

FLOOR

WF-01A

FLOOR

WF-01A

FLOOR

T-01

2 C-02 12 6

WF-01B

BASE

B-01

FLOOR

C-02

WF-01A

WF-01A

C

WF-01A

T-01

14

B-03

CPT-01

04 & 06-10 5 1

I

BASE

N/A

FLOOR

WF-01A

FINISH TAG

16

C

B-01

WALL

FLOOR

C-01

BASE

WF-01B B-01 C

C

10 WF-01A 6

B-01

C

C-02

E 2

2

N/A

EQ

MANUFACTURER

B-01

PAINTED WOOD WALL BASE

G.C.

B-02 B-03

RUBBER WALL BASE TILE COVE WALL BASE

SALES/LOUNGE/FITTING ROOMS BOH RESTROOM

C-01

CONCRETE TOPPING SLAB

REMOVABLE AREA RUG

FB-01 GL-01 MS-01

FABRIC - DRAPERY PANEL MIRROR MARBLE SADDLE

MT-01 MT-04

BRASS POWDER-COATED METAL WHITE INTERIOR PLASTER PLASTIC LAMINATE INTERIOR PAINT

FINISHES

PAINT GRADE POPLAR; PAINTED TBD

DIMENSIONS

FITTING ROOM ARCHED TRANSITION DISPLAY PLATFORMS WALL

TEXSTON

TUSCANY; COLOR: TBD

--

G.C. TO PROVIDE DRAW DOWNS FOR APPROVAL

FORMICA BEHR

COLORCORE - WHITE BIT OF SUGAR; PR-W14

---

TOP OF PLATFORM G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL; PAINT LINE AT BOH: 12'-0" AFF. G.C. TO PAINT ALL WALLS ABOVE THIS LINE PT-02. G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL TRIANGLE - ON POINT 6", 5/16" THK: GROUT: "MAPEI", COLOR: TBD; GROUT JOINT TO BE 1/8"; G.C. TO SEAL ALL GROUT PER MANUFACTURER'S RECOMMENDATIONS STRAIGHT SET - 2" X 6", 5/16" THK: GROUT: "MAPEI", COLOR: TBD; GROUT JOINT TO BE 1/8"; G.C. TO SEAL ALL GROUT PER MANUFACTURER'S RECOMMENDATIONS FINISH TO MATCH CONTROL SAMPLE FINISH TO MATCH CONTROL SAMPLE G.C. TO FOLLOW PLANS FOR PATTERN AND LAYOUT POINTS G.C. TO FOLLOW PLANS FOR PATTERN AND LAYOUT POINTS

INTERIOR PAINT

DOORS/WOOD BASE TRIM

BENJAMIN MOORE

SIMPLY WHITE OC-117; SEMI-GLOSS

--

PT-03

INTERIOR PAINT

CEILING

BENJAMIN MOORE

SIMPLY WHITE OC-117; FLAT

--

T-01

TILE FLOORING

RESTROOM

FIRECLAY TILE

TRIANGLE ON POINT - 6"; COLOR: TBD; FINISH MATTE NON-REFLECTIVE SURFACE

6"

T-02

WALL TILE

RESTROOM

FIRECLAY TILE

STRAIGHT SET - 2" X 6"; COLOR: TBD; FINISH MATTE NON-REFLECTIVE SURFACE

2" X 6"

WHITE OAK WALNUT WOOD ENGINEERED WOOD FLOOR

WF-01B

ENGINEERED WOOD FLOOR - HERRINGBONE PATTERN

A

6" H

PT-02

WD-01 WD-03 WF-01A

REMARKS/NOTES

REFER TO A-600 FOR DETAILS AND TRIM PROFILES JOHNSONITE TRADITIONAL WALL BASE; MODEL# JODC2824X; FINISH TBD 4"H REFER TO A-600 FOR DETAILS FIRECLAY TILE ARCHITECTURAL MOLDINGS 6" X 6" BASE; COLOR: TBD; FINISH MATTE 6" H ANCYRA, 6" X 6", .63" THK: GROUT: "MAPEI", NON-REFLECTIVE SURFACE COLOR: TBD; GROUT JOINT TO BE 1/8"; G.C. TO SEAL ALL GROUT PER MANUFACTURER'S RECOMMENDATIONS SALES UNCONVENTIONAL CEMETITIOUS OVERLAY; COLOR: LIGHT GRAY; FINISH: SEMI-GLOSS -GRIND, SEAL, AND POLISH W/ 16 GRIT DIAMOND FLOORING TO 1500 GRIT; G.C. TO TEST IN INCONSPICUOUS LOCATION AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT SALES/BOH G.C.'S VENDOR LIGHTWEIGHT CONCRETE; COLOR: LIGHT GRAY; FINISH: CLEAR MATTE -SEAL WITH CLEAR MATTE SEALANT G.C. TO SEALANT ENSURE SMOOTH ANS LEVEL FINISH WITHIN 1/4" OVER 10'-0"; G.C. TO TEST IN INCONSPICUOUS LOCATION AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT WINDOW DISPLAY, BOH & EXISTING EXISTING SLAB TO REMAIN -G.C. TO PREP FLOOR PER MANUFACTURERS STORAGE CLOSET RECOMMENDATIONS LOUNGE TBD TBD 116" W X 108" L NOT INSET; COORDINATE WITH FLOOR FINISH PLAN; BY OWNER (MODCLOTH) FITTING ROOMS HALF PRICE DRAPES SIGNATURE AQUA MIST BLACKOUT VELVET CURTAIN - VPCH-140803 50" W X 108" L BY OWNER (MODCLOTH) LOUNGE/FITTING ROOMS F.C. CLEAR REFLECTIVE MIRROR, TEMPERED REF. PLANS RESTROOM MARBLETHRESHOLDS.C WHITE GRAY POLISHED MARBLE THRESHOLD - DOUBLE STANDARD REF. PLANS F/I BY G.C.; REFER TO A-600 FOR DETAILS OM BEVEL TRANSITIONS/FIXTURES TBD TBD -F/I BY F.C. SIGNAGE SIGN VENDOR POWDER COAT TO MATCH PT-XX (TBD) -F/I BY SIGNAGE VENDER

FIXTURES MILLWORK LOUNGE/FITTING ROOMS/VESTIBULE LOUNGE/FITTING ROOMS

F.C. F.C. IV WOOD

NATURAL OAK WOOD, PLAIN SAWN; FINISH: CLEAR MATTE NATURAL WALNUT WOOD; FINISH: CLEAR MATTE WHITE OAK FLAT SAWN, CUSTOM BONOBOS MATTE FINISH

--3" W PLANKS

IV WOOD

WHITE OAK FLAT SAWN, CUSTOM BONOBOS MATTE FINISH

3" W PLANKS

FLOOR

WF-01A

EQ

2

2

12

12

WF-01A

WF-01A

7

F

2 12

6

10 11

10

PT-01

C-01

C-02

BASE

B-01

B-01

B-02

FLOOR

C-01

STORAGE CLOSET

WALL

PT-01

BASE

B-02

FLOOR

C-02

WALL

PT-01

BASE

B-02

FLOOR

C-02

1

PLATFORM DISPLAY AREA

8

01

C-02

WF-01A

TYP.

1

FLOOR

FLOOR

3

TYP.

WALL

B-01

B-01

WF-01A

3' - 0"

01

BASE

BASE

14

SALES

PT-01

PT-01

BACK OF HOUSE

2

WALL

WALL

13

3

6' - 8 3/8"

LOCATION

N/A

2

VIF

DESCRIPTION

CPT-01

B

9

FINISH CODE

EXISTING CONCRETE SLAB

16

WF-01A

FINISH SCHEDULE

RAISED CONCRETE SLAB

6

2

MT-01

FLOOR

BASE

12

12

C

02

BASE

PL-01

2

MT-01

PT-01A

WALL

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

VESTIBULE

2 12

WALL

WALL

FITTING ROOM TRANSITION

15

C

LOUNGE TRANSITION

ROOM #

PLM-01 PT-01

C

02

ROOM NAME

12

D

LOUNGE TRANSITION

LAYOUT STARTING POINT

12

4

FACP

NEW ENGINEERED WOOD FLOOR HERRINGBONE PATTERN WF-01B

PT-01

2

12

13

B-01

WALL

WF-01A

2

2 12

EQ

NEW ENGINEERED WOOD FLOOR WF-01A

H

WF-01A

02

PL-01

1

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

WF- 01B HERRINGBONE FLOOR PATTERN 3" WIDE PLANKS

PLATFORM DISPLAY AREA

C-EXG

2

MEP ENGINEER:

NEW TILE FLOOR T-01

C-02

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

WALL

EQ

HATCH / SYMBOL

ARCHITECT OF RECORD:

15

2

G C-02

C-02

1

1

FLOOR & WALL FINISH PLAN

STAMP HERE:

SCALE: 1/4" = 1'-0"

FLOOR AND WALL FINISH PLAN GENERAL NOTES: 1. ALL FINISHING AND PAINTING REQUIREMENTS BE AS PER FINISH SCHEDULE, ELEVATIONS AND SPECIFICATIONS. 2. ALL INTERIOR GWB PAINT TO BE SPRAY APPLIED AND BACKROLL FINISHED. SAMPLE TO BE PROVIDED TO ARCHITECT FOR APPROVAL. G.C. AND F.C. TO COORDINATE AND MATCH PAINTED FINISHES. 3. ALL CONCRETE FINISHES TO FOLLOW DESCRIPTION PROVIDED IN FINISH SCHEDULE; SAMPLE TO BE PROVIDED IN FINISH SCHEDULE; G.C. TO TEST FINISH IN BOH AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT. 4. INSTALLATION OF FINISHES AND FIXTURES TO BE COORDINATED BETWEEN G.C., F.C., AND ALL VENDORS, TYP. 5. G.C. TO SUBMIT SAMPLES OF ALL FINISHES FOR FINAL APPROVAL PRIOR TO ORDERING OF MATERIALS OR INSTALLATION.

FLOOR AND WALL FINISH PLAN KEY NOTES: 1

LEASE LINE

2

G.C. TO SUPPLY AND INSTALL NEW PAINTED WOOD WALL BASE, B-01; REF. A-600 FOR DETAILS

3

G.C. TO SUPPLY AND INSTALL NEW RUBBER WALL BASE, B-02; REF. A-600 FOR DETAILS

4

G.C. TO SUPPLY AND INSTALL NEW TILE COVE WALL BASE; B-03; REF. A-600 FOR DETAILS

5

G.C. TO SUPPLY AND INSTALL NEW ADA COMPLIANT MARBLE SADDLE THRESHOLD; REF. A-600 FOR DETAILS

6

G.C. TO SUPPLY AND INSTALL NEW BRASS SCHLUTER STRIP THRESHOLD; REF. A-600 FOR DETAILS

7

EXISTING THRESHOLD AT STOREFRONT ENTRY TO BE REPLACED; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)

8

6. ALL MATERIALS AND FINISHES MUST BE FIRE-RATED AND HAVE FLAME RESISTANCE COMPLYING WITH LOCAL & STATE CODES. 9

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK

G.C. TO RUN POWER TO DESK AREA PRIOR TO POURING NEW SLAB ; REF. A-103 POWER & SIGNAL PLAN

CHECKED BY: JSP

NEW REMOVABLE WALK-OFF MAT AT STOREFRONT ENTRY

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

7. ALL SURFACES AT TRANSITIONS BETWEEN DIFFERENT OR EXISTING NEW MATERIALS TO BE FLUSH AND/OR A.D.A. COMPLIANT

10

NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0"

8. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.

11

NEW 3/8"THK POLISHED CONCRETE TOPPING AT ALL SALES AREAS; G.C. TO FLOAT SUBFLOOR AS REQ'D TO ENSURE FINISHED FLOOR ALIGNS WITH ENTRY THRESHOLD; REF. A-600

12

NEW ENGINEERED WOOD FLOOR; G.C. TO LEVEL SUBFLOOR AND FLOAT AS REQ'D TO ENSURE FINISHED FLOOR ALIGNS WITH ADJACENT FLOORS; REF. A-600; AND PROVIDE CONTINUOUS VAPOR BARRIER AT ALL WOOD FLOORING

13

NEW REMOVABLE AREA RUG BY OWNER (MODCLOTH ); NO TRIP HAZARD AT PERIMETER OF AREA RUG. CARPET TO COMPLY WITH ADA LEVEL CHANGE REQUIREMENTS (ADA 2010 SECTION 303) AND SHALL NOT EXCEED 1/4" THK. OR 1/2" THK IF EDGE IS BEVELED AT A SLOPE NOT STEEPER THAN 1:2.

14

NEW TILE FLOOR AT RESTROOM. G.C. TO PROVIDE CONTINUOUS VAPOR BARRIER UNDER FLOOR AND 4" MIN. UP ADJACENT WALLS.

15

G.C. TO USE MOISTURE-RESISTANT TYPE "X" GWB AT THE WALLS IN WET AREAS, INCLUDING THE RESTROOM AND MOP SINK, TYP.

16

LAYOUT STARTING POINT

AREA: 1807 SQ.FT

FLOOR AND WALL FINISH PLAN

A-104.00 SHEET 13 OF 30


3' - 8 1/2"

EXISTING SLAB TO REMAIN EXPOSED AND CONCEALED UNDERNEATH NEW STOREFRONT PLATFORMS

3' - 2 5/8"

-0' - 3 1/4"AFF

2 7/8" 8"

1' - 5 3/4" 9' - 1 5/8"

6' - 7 3/4" 2 7/8"

2

MEP ENGINEER:

16' - 6 5/8"

EXISTING SLAB TO REMAIN; PREP FOR NEW WOOD FLOOR INSTALL

16' - 0 1/2" 2

9' - 8"

7' - 1 5/8"

5' - 4 3/4"

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

2' - 1 3/4"

2 7/8"

4' - 6 1/4"

2' - 0"

2' - 0 5/8"

A-105.00 TYP.

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

6' - 11 3/8"

- 0' - 3/8"AFF

EXISTING SLAB

NEW RAISED SLAB SLOPED TO FLOOR DRAIN AT CENTER OF RESTROOM; PREP FOR NEW TILE FLOOR INSTALL; COORD. WITH A-100 CONSTRUCTION PLAN FOR RESTROOM EXTENT

4

3' - 8 7/8"

NEW 2 7/8"THK RAISED SLAB

ARCHITECT OF RECORD:

3' - 7 1/4" 1

2 7/8"

3/8"

3 1/8"

NEW 2 7/8"THK RAISED SLAB

- 0' - 3/8"AFF

1

- 0' - 3/8"AFF NEW RAISED SLAB TO BE LEFT AS EXPOSED FINISH FLOOR AT BACK OF HOUSE AND VESTIBULE CLOSET

21' - 3"

3

2' - 7 3/8"

NEW 2 7/8"THK RAISED SLAB

18' - 7 5/8"

NEW RAISED SLAB; PREP FOR NEW CONCRETE TOPPING

1

2' - 7 3/8"

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

3

1

NEW RAISED SLAB TO REMAIN EXPOSED AND CONCEALED UNDERNEATH NEW STOREFRONT PLATFORMS

1 WALL BASE AS SCHEDULED; REF. A-104 FLOOR FINISH PLAN

ALIGN

NEW 5/8"THK GLUE DOWN WOOD FLOOR WHERE SCHEDULED; REF. A104 FLOOR FINISH PLAN

NEW 2 7/8"THK RAISED LIGHTWIGHT CONCRETE SLAB, G.C. TO ENSURE LEVEL FINISH WITHIN 1/4" OVER 10'-0"; PREP FOR NEW CONCRETE TOPPING WHERE SCHEDULED C-02

3/4"THK PLYWOOD SUBFLOOR WOOD SLEEPERS SPACED @ 24" O.C.

3/8"

TOPPING SLAB & T.O. WOOD FLOOR -0' - 0 3/8" A.F.F.

2 7/8"

CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.

1 7/8"

3/4"

5/8"

0' - 0" A.F.F.

RAISED SLAB

STAMP HERE:

SCALE: 1/4" = 1'-0"

HATCH / SYMBOL

DESCRIPTION

EXISTING PARTITION TO REMAIN

SLAB PLAN GENERAL NOTES: 1. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLAN(S) AND EXISTING CONDITIONS. 2. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER.

X" HEIGHT DIFFERENCE

WALL BASE AS SCHEDULED; REF. A-104 FLOOR FINISH PLAN

SLAB LEVEL PLAN

HATCH & SYMBOL LEGEND

NEW 3/8"THK CONCRETE TOPPING SLAB WHERE SCHEDULED, REF. A-104 FLOOR FINISH PLAN; G.C. TO ENSURE NEW FLOOR IS LEVEL WITH EXISTING STOREFRONT THRESHOLD C-01

1 A-202.00

LOCATION OF SLAB LEVEL CHANGE

3. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL OR COLUMN U.N.O. DO NOT SCALE DRAWINGS UNDER ANY CIRCUMSTANCES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER THE SCALE ON THE CONSTRUCTION DOCUMENTS. 4. G.C. TO COORD. SLAB EDGE LOCATION WITH A-100 CONSTRUCTION PLAN. 5. THIS PROJECT IS EXEMPT FROM CONCRETE TESTING (TR2 AND TR3) PER NYCBC 1704.4 EXCEPTION 2. TOTAL CONCRETE PLACEMENT ON THIS PROJECT IS 32 CUBIC YARDS.

SLAB PLAN KEY NOTES: 1

LEASE LINE

2

G.C. TO CLEAN EXISTING SLAB AND PREP FOR NEW FLOOR FINISH U.N.O.; REF. A-101 FLOOR FINISH PLAN

3

G.C. TO POUR NEW 2 7/8"THK RAISED CONCRETE SLAB AND PREP FOR NEW FLOOR FINISH U.N.O.; COORD. SLAB EDGE LOCATION WITH A-100 CONSTRUCTION PLAN

4

G.C. TO SLOPE NEW CONCRETE SLAB AT RESTROOM TO FLOOR DRAIN; COORD. WITH A-100 CONSTRUCTION PLAN AND PLUMBING DRAWINGS

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

-0' - 3 1/4" A.F.F. EXISTING SLAB

EXISTING CONCRETE SLAB, G.C. TO PREP FOR NEW FLOOR FINISHES AS SCHEDULED C-EXG

2

SLAB EDGE - CONCRETE TOPPING / WOOD FLOOR SCALE: 6" = 1'-0"

SLAB LEVEL PLAN

A-105.00 SHEET 13 OF 27


ARCHITECT OF RECORD:

EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH

NEW CHANDELIER, TYP.

GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F. MEP ENGINEER:

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. 11' - 0" A.F.F. SALES CEILING

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

11' - 0" A.F.F. LOUNGE POP-UP

PT-01A

WC-01

4' - 10"

PT-01A

LOUNGE

02

5 1/4"

PT-01A

SALES

10' - 0" A.F.F. LOUNGE CEILING

01

6' - 11"

8' - 0"

9' - 0" A.F.F. SALES TRANSITION

CH-03

2

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

0' - 0" A.F.F. FINISHED FLOOR

F.26

SECTION A SCALE: 1/2" = 1'-0"

NEW CHANDELIER, TYP.

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. 11' - 0" A.F.F. SALES CEILING

STAMP HERE:

11' - 0" A.F.F. LOUNGE POP-UP

PT-01A

SALES

LOUNGE

01

02

WC-01

10' - 0" A.F.F. LOUNGE CEILING 9' - 0" A.F.F. SALES TRANSITION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT

0' - 0" A.F.F. FINISHED FLOOR

1

SECTION B SCALE: 1/2" = 1'-0"

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

BUILDING SECTIONS

A-300.00 SHEET 14 OF 27


ARCHITECT OF RECORD:

SUSPENDED LED LIGHT, TYP.

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.

MEP ENGINEER:

13' - 3 3/4" A.F.F. LIGHT COVE 12' - 8" A.F.F. FR LOUNGE T.O. ARCH

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

11' - 0" A.F.F. SALES CEILING

PT-01A

9' - 0" A.F.F. FITTING ROOM CEILING

7' - 6" A.F.F. T.O. OPENING

FR 5 STORAGE CLOSET

FITTING ROOM LOUNGE

05

09

03

SALES

1' - 6"

5' - 0"

8' - 0"

01

0' - 0" A.F.F. FINISHED FLOOR

A.01

2

CH-01

F.01

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

-0' - 3 1/4" A.F.F. T.O. EXG SLAB

F.03

SECTION C SCALE: 1/2" = 1'-0"

NEW CHANDELIER, TYP.

EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH

DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. STAMP HERE:

11' - 0" A.F.F. LOUNGE POP-UP

FITTING ROOM LOUNGE

03

LOUNGE

02

PT-01A

10' - 0" A.F.F. LOUNGE CEILING PT-01A

9' - 0" A.F.F. FR LOUNGE TRANSITION VESTIBULE

WC-01

VESTIBULE

STORAGE CLOSET

12

13 THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018

PT-01A

DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

1' - 6"

2' - 10"

DOOR TO RESTROOM 02

0' - 0" A.F.F. FINISHED FLOOR

BUILDING SECTIONS

-0' - 3 1/4" A.F.F. T.O. EXG SLAB F.03

1

SECTION D SCALE: 1/2" = 1'-0"

CH-03

A-301.00 SHEET 15 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

13' - 3 3/4" A.F.F. LIGHT COVE 12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN

EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH

NEW CHANDELIER, TYP.

MODCLOTH NEON SIGN

11' - 0" A.F.F. SALES CEILING

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D

PT-01A

11' - 0" A.F.F. SALES CEILING

PT-01A

EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH

F.03

F.02

9' - 0" A.F.F. SALES TRANSITION

EXISTING STOREFRONT SYSTEM AND GLAZING

4

F.18

NEW FIXTURE BY F.C., TYP.

GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D

1' - 6"

TYP.

1' - 6"

TYP.

2' - 10"

PLATFORM

2' - 4 1/4"

F.03

0' - 0" A.F.F. FINISHED FLOOR NEW FIXTURE BY F.C. COORD IN-WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN

F.18

NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B

SALES WEST

2

SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR NEW DUPLEX RECEPTACLE F.23

B-01 PT-01B

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

F.03

OPEN TO LOUNGE BEYOND

2' - 6 3/4" A.F.F. WINDOW SILL 2' - 5" A.F.F. T.O. PLATFORM

PLATFORM

2' - 4 1/4"

NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PLM-01

SALES EAST SCALE: 1/2" = 1'-0"

13' - 3 3/4" A.F.F. LIGHT COVE

EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH

EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH

11' - 0" A.F.F. SALES CEILING

NEW CHANDELIER, TYP.

STAMP HERE:

MODCLOTH NEON SIGN 11' - 0" A.F.F. SALES CEILING

10' - 10" A.F.F. T.O. DOOR

F.25 PT-01A

9' - 0" A.F.F. SALES TRANSITION

F.03 F.02

10' - 8 3/4"

FIRE ALARM SPEAKER STROBE; FINISH WHITE; MOUNT AT 96" AFF MAX (80" MIN.)

F.01

F.01

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

EXISTING DOOR PULLS TO REMAIN

EXISTING STOREFRONT DOOR TO REMAIN

PROJECT NO.: 218231

EX-01

DATE: 08/20/2018

EXISTING FIRE ALARM PANEL

DRAWN BY: GR, RE, NK

FIRE-PULL

SALES SOUTH SCALE: 1/2" = 1'-0"

B.O. CHANDELIER

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

B-01 PT-01B

B-01 PT-01B

1

SALES NORTH SCALE: 1/2" = 1'-0"

MQ

NEW FIXTURE BY F.C. COORD IN-WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS

AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

2' - 5" A.F.F. T.O. PLATFORM 2' - 4 1/4"

F.23

CHECKED BY: JSP

PLATFORM

4' - 3"

2' - 5" A.F.F. T.O. PLATFORM

PLATFORM

2' - 4 1/4"

NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B

3

7' - 0"

NEW BESTLOCKS; G.C. TO PROVIDE 6 SETS OF KEYS

NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B

GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D

F.23

INTERIOR ELEVATIONS SALES SHOP

A-302.00 SHEET 16 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D

11' - 0" A.F.F. LOUNGE POP-UP

NEW CHANDELIER, TYP. 11' - 0" A.F.F. LOUNGE POP-UP

10' - 0" A.F.F. LOUNGE CEILING PT-01A

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

10' - 0" A.F.F. LOUNGE CEILING PT-01A

9' - 0" A.F.F. SALES TRANSITION

GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D

F.05

NEW GLASS FIXTURE BY F.C.

EXISTING STOREFRONT SYSTEM AND GLAZING OPEN TO SALES SHOP BEYOND

PALTFORM

2' - 4 1/4"

TYP.

1' - 6"

HOLD

NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B

2' - 10"

TEMPERATURE SENSOR

0' - 0" A.F.F. FINISHED FLOOR

4

CH-03

F.20

NEW DUPLEX RECEPTACLE

CH-03

B-01 PT-01B

LOUNGE WEST

2

SCALE: 1/2" = 1'-0"

CH-03

F.25

CH-03

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

LOUNGE SOUTH SCALE: 1/2" = 1'-0"

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. NEW CHANDELIER, TYP. NEW CHANDELIER, TYP. EXISTING PRECAST COLUMNG TO REMAIN; G.C. TO GRIND AND POLISH

NEW MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

EXISTING PRECAST COLUMN; G.C TO GRIND AND POLISH

11' - 0" A.F.F. LOUNGE POP-UP

11' - 0" A.F.F. LOUNGE POP-UP

10' - 0" A.F.F. LOUNGE CEILING

10' - 0" A.F.F. LOUNGE CEILING

9' - 0" A.F.F. FR LOUNGE TRANSITION

9' - 0" A.F.F. SALES TRANSITION WC-01

PT-01A A.03

PT-01A

PT-01A

A.03 THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

GLASS LOUNGE SCREEN NEW GLASS FIXTURE BY F.C. F.05

NEW GLASS FIXTURE BY F.C. F.05

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

OPEN TO VESTIBULE BEYOND

0' - 0" A.F.F. FINISHED FLOOR

3

SCALE: 1/2" = 1'-0"

CH-03

1

LOUNGE EAST SCALE: 1/2" = 1'-0"

DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

1' - 6"

PLATFORM

2' - 4 1/4"

2' - 10"

0' - 0" A.F.F. FINISHED FLOOR B-01 PT-01B

PROJECT NO.: 218231 DATE: 08/20/2018

NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B

LOUNGE NORTH

STAMP HERE:

F.20

CH-03

B-01 PT-01B

INTERIOR ELEVATIONS LOUNGE SHOP

A-303.00 SHEET 17 OF 27


12' - 8" A.F.F. FR LOUNGE T.O. ARCH

12' - 8" A.F.F. FR LOUNGE T.O. ARCH DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION

PT-01A

ARCHITECT OF RECORD:

DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION

PT-01A

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

FITTING ROOM CURTAIN BEYOND INSTALLED ON RODS AND RINGS

A.02

8' - 3" A.F.F. ARCHED FR TRANS. TYP.

8' - 3" A.F.F. ARCHED FR TRANS. TYP.

PT-01

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

FITTING ROOM CURTAIN BEYOND INSTALLED ON RODS AND RINGS PT-01 FB-01

OPEN TO ADA FITTING ROOM

OPEN TO FITTING ROOM 04

PL-01

OPEN TO FITTING ROOM 05

OPEN TO FITTING ROOM 01

PT-01

B-01 PT-01B

OPEN TO FITTING ROOM 02

FB-01

0' - 0" A.F.F. FINISHED FLOOR

OPEN TO FITTING ROOM 03

B-01 PT-01B

FB-01 FB-01

FR LOUNGE WEST

3

SCALE: 1/2" = 1'-0"

12' - 8" A.F.F. FR LOUNGE T.O. ARCH

0' - 0" A.F.F. FINISHED FLOOR

FR LOUNGE EAST SCALE: 1/2" = 1'-0"

12' - 8" A.F.F. FR LOUNGE T.O. ARCH DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION

DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION PT-01

OPEN TO MIRROR NICHE

1" TAPED IN LINEAR SLOT

8' - 3" A.F.F. MIRROR NICHE CEILING

PT-01

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

PT-01A

7' - 6" A.F.F. T.O. OPENING

A.01

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

A.02 PT-01

OPEN TO LOUNGE OPEN TO VESTIBULE

9' - 0" A.F.F. FITTING ROOM CEILING PT-01A

MODCLOTH WALLCOVERING

EQ

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. INWALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

A.05 A.04

A.05

EQ NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

A.06

A.05

6' - 6"

A.02

8' - 3" A.F.F. MIRROR NICHE CEILING

9' - 0" A.F.F. FITTING ROOM CEILING

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

9' - 0" A.F.F. FITTING ROOM CEILING

9' - 0" A.F.F. FR LOUNGE TRANSITION

6' - 6"

9

NEW ILLUMIANTED 3-WAY MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION

FB-01

A.06

0' - 0" A.F.F. FINISHED FLOOR

13

FR LOUNGE SOUTH

0' - 0" A.F.F. FINISHED FLOOR

11

SCALE: 1/2" = 1'-0"

FR LOUNGE NORTH

B-01 PT-01B

8

SCALE: 1/2" = 1'-0"

9' - 0" A.F.F. FITTING ROOM CEILING

FR 1,2,3 TYP. SOUTH

5

SCALE: 1/2" = 1'-0"

9' - 0" A.F.F. FITTING ROOM CEILING

B-01 PT-01B

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

A.07

A.06

2

SCALE: 1/2" = 1'-0"

EQ

EQ A.06

A.07

A.05

HIDDEN DOOR TO STORAGE CLOSET

B-01 PT-01B

STAMP HERE:

SCALE: 1/2" = 1'-0"

9' - 0" A.F.F. FITTING ROOM CEILING

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

0' - 0" A.F.F. FINISHED FLOOR

FR 4,5 TYP. SOUTH

9' - 0" A.F.F. FITTING ROOM CEILING

PT-01A PT-01A

FB-01

FR 4,5 TYP. WEST

9' - 0" A.F.F. FITTING ROOM CEILING

PT-01A

FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS

0' - 0" A.F.F. FINISHED FLOOR

TYP.

0' - 0" A.F.F. FINISHED FLOOR

9"

9"

B-01 PT-01B

B-01 PT-01B

TYP.

A.06

PT-01A

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

NEW MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

A.04 A.05

A.05

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

A.04

06

FB-01

MODCLOTH WALLCOVERING A.06

FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS

A.06

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

B-01 PT-01B

12

FR 1,2,3 TYP. WEST SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR B-01 PT-01B

B-01 PT-01B

10

FR 1,2,3 TYP. NORTH SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR

7

FR 1,2,3 TYP. EAST SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR

B-01 PT-01B

4

FR 4,5 TYP. NORTH SCALE: 1/2" = 1'-0"

B-01 PT-01B

1

FR 4,5 TYP. EAST SCALE: 1/2" = 1'-0"

INTERIOR ELEVATIONS FR AND FR LOUNGE

A-304.00 SHEET 18 OF 27


ARCHITECT OF RECORD:

1' - 8"

A.04

ADA BENCH BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D F.12

A.04 A.04

HOLD HOLD

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

F.12

6"

0' - 0" A.F.F. FINISHED FLOOR

6"

B-01 PT-01B

B-01 PT-01B

1' - 8"

HOLD 1' - 5"

TYP.

9"

0' - 0" A.F.F. FINISHED FLOOR

1' - 9"

4"

TYP. 4' - 0"

5' - 0"

TYP.

HOLD

4' - 0"

5' - 0"

TYP.

HOLD 5' - 0"

4' - 0"

A.05

6"

4" HOLD 1' - 5"

1' - 9"

1' - 2"

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

3' - 0"

B-01 PT-01B

3' - 6"

6"

F.12

ADA FR WEST

9

SCALE: 1/2" = 1'-0"

ADA FR SOUTH

6

SCALE: 1/2" = 1'-0"

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

1' - 2"

0' - 0" A.F.F. FINISHED FLOOR

1' - 8"

HOLD

HOLD

12

MEP ENGINEER:

A.06

1' - 3"

6"

6"

HOLD

A.05

2' - 2 1/4"

2' - 7 1/4"

6"

6' - 6"

A.04

1' - 0"

1' - 0"

A.04

1' - 0"

FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS

HOLD

A.04

2' - 0"

FB-01

PT-01A

TYP. 5' - 0"

2' - 2 1/4"

6"

BRASS METAL HOOKS FURNISHED AND INSTALLED BY G.C; G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. INWALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

4' - 0"

A.06

EQ.

PT-01A

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

9' - 0" A.F.F. FITTING ROOM CEILING

TYP.

2' - 7 1/4"

EQ.

NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION

4' - 0"

2' - 2 3/4"

5"

PT-01A

HOLD 5' - 0"

MODCLOTH WALLCOVERING

9' - 0" A.F.F. FITTING ROOM CEILING

1' - 0"

9' - 0" A.F.F. FITTING ROOM CEILING

1' - 0"

9' - 0" A.F.F. FITTING ROOM CEILING

HOLD

ADA FR NORTH

3

SCALE: 1/2" = 1'-0"

ADA FR EAST SCALE: 1/2" = 1'-0"

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. SUSPENDED LED LIGHT, TYP. 9' - 0" A.F.F. VESTIBULE

9' - 0" A.F.F. VESTIBULE

PT-01A

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

7' - 6" A.F.F. T.O. OPENING PT-01A PT-01A

8' - 5 1/2"

PT-01A

DOOR TO BOH 04

OPEN TO FR LOUNGE

48" MAX.

HIDDEN DOOR TO FITTING ROOM

06

0' - 0" A.F.F. FINISHED FLOOR

B-01 PT-01B

11

B-01 PT-01B

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

STORAGE WEST

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

8

SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR

STORAGE SOUTH

5

SCALE: 1/2" = 1'-0"

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

VESTIBULE WEST

2

SCALE: 1/2" = 1'-0"

VESTIBULE SOUTH

STAMP HERE:

SCALE: 1/2" = 1'-0"

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

SUSPENDED LED LIGHT, TYP.

SUSPENDED LED LIGHT, TYP. 9' - 0" A.F.F. VESTIBULE

9' - 0" A.F.F. VESTIBULE PT-01A

PT-01A

EXISTING PRECAST CONCRETE COLUMN; G.C. TO GRIND AND POLISH

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT

PT-01A

PT-01A

EXISTING PRECAST CONCRETE COLUMN; G.C. TO GRIND AND POLISH

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

10

STORAGE NORTH SCALE: 1/2" = 1'-0"

7

STORAGE EAST SCALE: 1/2" = 1'-0"

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

B-01 PT-01B

0' - 0" A.F.F. FINISHED FLOOR

4

VESTIBULE NORTH SCALE: 1/2" = 1'-0"

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

DOOR TO RESTROOM 02

DOOR TO CLOSET 03

B-01 PT-01B

#

B-01 PT-01B

1

VESTIBULE EAST SCALE: 1/2" = 1'-0"

INTERIOR ELEVATIONS VESTIBULE, STORAGE ROOM AND ADA FR

A-305.00 SHEET 19 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

SUSPENDED LED LIGHT, TYP.

EXISTING PRECAST CONCRETE COLUMN

SUSPENDED LED LIGHT, TYP.

EXISTING STEEL DUCTING; TYP.

EXISTING STEEL DUCTING; TYP. 12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

AHU

AHU

BR BST B12

PT-01A

9' - 0" A.F.F. T.O. PARTIAL HEIGHT WALL

1' - 4"

6"

PT-01A

SH12 SH16

1' - 4"

TDSH

1' - 4"

1' - 0"

PL.05

1' - 8"

KB

9' - 0"

PL.04

9' - 0"

ACCESS PANEL

UH

PW-01

PL.06

BOH SOUTH

4' - 0"

BOH SHELVING

CF

B-02

BOH NORTH

3

SCALE: 1/2" = 1'-0"

SCALE: 1/2" = 1'-0"

4' - 0"

TELE/DATA BOARD EQUIP. LEGEND

2

SOUND GENERATION - AMP RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

3

PLAYLIST GENERATION - AUDIO RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

4

SUSPENDED LED LIGHT, TYP.

EXISTING STEEL DUCTING; TYP.

EXISTING STEEL DUCTING; TYP. 12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. AHU

AHU

ADT MONITOR G.C. TO COORD. & SUPERVISE VENDOR INSTALL

5

AUDIO CONTROLLERS - MOUNT AT 48" AFF MAX. G.C. TO COORD. & SUPERVISE VENDOR INSTALL

6

BANDWAVE - PEPWAVE - CELLULAR ROUTER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

7

RETAIL NEXT - ALLIED TELESIS - POE SWITCH (ONLY OCCURS AT MEDIUM TO LARGE STORES) G.C. TO COORD. & SUPERVISE VENDOR INSTALL

8

ISP INTERNET HAND-OFF G.C. TO COORD. & SUPERVISE VENDOR INSTALL

9

RETAIL NEXT - HIK VISION G.C. TO COORD. & SUPERVISE VENDOR INSTALL

1' - 4 1/2"

BST B12 B16

SH12 SH16

3

NEW TELE/DATA BOARD 3/4" FRT PLYWOOD, PAINTED TO MATCH ADJACENT FINISH 2 PT-01A

SCALE: 1/2" = 1'-0"

MIN. 4' - 0"

TYP.

1' - 6"

TYP.

1' - 6"

4' - 0"

48" MAX.

04

5

7' - 0"

16 ADT VIDEO RECORDER G.C. TO COORD. & SUPERVISE VENDOR INSTALL

DOOR TO VESTIBULE

0' - 0" A.F.F. FINISHED FLOOR

2

BOH EAST SCALE: 1/2" = 1'-0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

11

15 ADT ALARM SIREN G.C. TO COORD. & SUPERVISE VENDOR INSTALL

BOH SHELVING

12

8 7

11 ADT SWITCH G.C. TO COORD. & SUPERVISE VENDOR INSTALL

14 KB: KEYBOX - MOUNT AT 48" AFF MAX. G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.

B-02

13

6

16

12 ADT MAIN BOX G.C. TO COORD. & SUPERVISE VENDOR INSTALL

05

BOH WEST

STAMP HERE:

9

BLIND DOOR TO DISPLAY PLATFORM

DISPLAY PLATFORM

15

1

13 CISCO MERAKI FIREWALL - G.C. TO SUPERVISE VENDOR INSTALL

0' - 0" A.F.F. FINISHED FLOOR

1' - 4 1/2"

5' - 0"

PT-01A

5"

4

14

TELE/DATA BOARD W/ DESK SCALE: 1" = 1'-0"

DATE: 08/20/2018 CHECKED BY: JSP AREA: 1807 SQ.FT

B-02

1

PROJECT NO.: 218231 DRAWN BY: GR, RE, NK

5 10

MOUNT ALL LOW VOLTAGE EQUIP. ABOVE 36" AFF

BOH SHELVING

5"

EQ

10 POWER GEAR SURGE PROTECTOR G.C. TO FURNISH AND INSTALL

9' - 0" A.F.F. T.O. PARTIAL HEIGHT WALL

BOH SHELVING

5"

EQ

MOUNT KEYBOX, AUDIO CONTROLS, AND KEPAD AT 48" AFF MAX. 3' - 0"

PT-01A

TDSH: WALL MOUNTED RECEIVER SHELF G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.

3"

1

SUSPENDED LED LIGHT, TYP.

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

ELECTRICAL PANEL

0' - 0" A.F.F. FINISHED FLOOR

7' - 9"

4

TIME CLOCK

0' - 0" A.F.F. FINISHED FLOOR

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

2' - 6"

REF-2

B-02

TYP.

1' - 6"

2' - 10"

TYP.

3' - 8"

DSK

INTERIOR ELEVATIONS BOH

A-306.00 SHEET 20 OF 27


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

7' - 3 5/8" HOLD

3' - 0"

1' - 0"

1' - 0"

GB

2

1'-6" MAX.

9

GB

3

MR

4

11

TYP. ADA RESTROOM 11

9

7

8 2

5

TD

0' - 0" A.F.F. FINISHED FLOOR B-03

SCALE: 1/2" = 1'-0"

14

1' - 10 1/8"

3' - 0 1/8"

PROVIDE WHIP CONNECTION FOR LIGHT FIXTURE; MOUNT 7'-0" AFF

3' - 0"

60"Ø TURNING SPACE

3

1' - 3"

3

CLEAR TYP.

CB

13

1

4

1' - 0"

4

9' - 0" A.F.F. RESTROOM CEILING

9' - 0" A.F.F. RESTROOM CEILING

1' - 5"

TYP.

TYP.

OS

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

3

SCALE: 1/2" = 1'-0"

60" CLEAR

1' - 2"

RESTROOM SOUTH

2' - 11 1/8"

B-03

HOLD

12

TYP.

6' - 4 1/8"

15 TPH

8 1/2"

A-307.00 4

8 1/2"

1' - 6"

3

56" CLEAR

2' - 4"

PL.03

3' - 6"

TPH

1' - 4"

48" MIN.

15

4' - 3 3/4"

HOLD

5' - 0"

HOLD

5' - 0"

48" MIN.

HOLD 4' - 3 3/4"

3' - 8"

PL.02

6

0' - 0" A.F.F. FINISHED FLOOR

RESTROOM WEST

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

10

PL.01

PL.03

7"

T-02

T-02

5

MEP ENGINEER:

1' - 6"

DOOR TO VESTIBULE 02

CB

3' - 9 5/8" 1

EQ CB

1' - 11 1/2"

2' - 0"

2' - 4"

1' - 0 1/2"

G.F.I @ 48" AFF

1' - 2"

EQ

6"

9' - 0" A.F.F. RESTROOM CEILING

6 5/8"

9' - 0" A.F.F. RESTROOM CEILING

PROVIDE WHIP CONNECTION FOR LIGHT FIXTURE; MOUNT 7'-0" AFF 1' - 6"

MR

CLEAR 2' - 8 1/2"

3' - 0"

GB

3' - 7 1/4"

MR 5

TD PL.02

1' - 5 3/4"

PL.01

7"

PL.02

TPH

RESTROOM NORTH

4

2

SCALE: 1/2" = 1'-0"

40" AFF MAX V.I.F.

48" MIN.

4' - 3 3/4"

1' - 4" 1' - 6"

T-02

0' - 0" A.F.F. FINISHED FLOOR

B-03

15

MAX.

2' - 10"

3' - 7"

48" MIN.

4' - 3 3/4"

T-02

TYP.

4' - 0"

PL.01

B-03

PL.03

BOTTOM OF REFLECTIVE SURFACE

1' - 6"

TD

0' - 0" A.F.F. FINISHED FLOOR

RESTROOM EAST

1

SCALE: 1/2" = 1'-0"

HATCH & SYMBOL LEGEND SYMBOL

EXISTING PARTITION TO REMAIN NEW PARTITION FURNITURE / FIXTURE / EQUIPMENT TAG

RESTROOM ACCESSORIES TAG DSK

DESCRIPTION WALL MOUNTED DESK

EL

EMPLOYEE LOCKER

GB KB

ADA GRAB BARS KEY BOX

MR TD

RESTROOM MIRROR RECESSED PAPER TOWEL DISPENSER TOILET PAPER HOLDER

TPH

DIMENSIONS MANUFACTURER 42"L x 24"D x 34"H THE CONTAINER STORE 12"W x 18"D x ULINE 72"H 18"L, 36"L, 42"L KOHLER 11.7"H x 7.9"W x MMF INDUSTRIES 3.6"D 24"W X 36"H REJUVENATION 19"H X 13"W X 4 FAUCETSINHOME 1/4"D 2 1/2"W X 3"D X GATCO 6"H

MODEL WHITE MELAMINE DESK

RESPONSIBILITY G.C.

QUANTITY 1

NOTES / REMARKS COORD. INSTALL WITH BOH REFRIGERATOR (REF-2); REF. ELEVATIONS GRAY

H-1845GR

G.C.

1

K-14561-AF, K-14564-AF, K-14565-AF 201202889

G.C. G.C.

1 EA. 1

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS COORD. W/ TELE/DATA BOARD

E4337 FTH13078

G.C. G.C.

1 1

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS RECESSED INTO WALL

4493 (BRONZE)

G.C.

1

G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS

PLUMPING FIXTURES TAG PL.01

DESCRIPTION RESTROOM SINK

DIMENSION 20"W X 18"D

MANUFACTURER KOHLER

MODEL K-2084

RESPONSIBILITY G.C.

PL.02 PL.03

RESTROOM SINK FAUCET RESTROOM TOILET

2.2"W X 6.5"D X 6.5"H 17 5/8"W X 28 3/4"D X 30 3/4"H

MAC FAUCET KOHLER

FA444HD-17 CIMARRON K-3609

G.C. G.C.

PL.04 PL.05

SERVICE SINK SERVICE SINK FAUCET

21"W X 21 1/2"D X 44 1/2"H 8" SPREAD

TSA-1MOP B-0674-RGH

G.C. G.C.

PL.06 PL.07

WATER COOLER FLOOR DRAIN

TURBO AIR T&S BRASS AND BRONZE WORKS, INC. QUENCH MIFAB

750 F1100-2, (POLISHES BRASS TYPE 5 INCH ONLY)

G.C. G.C.

13 1/2"W x 14 1/2"D x 40 1/2"H 6"Ø STRAINER

QUANTITY NOTES / REMARKS 1 G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. 1 COORD. W/ MEP DWGS. GOLD POLISH FINISH 1 G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS.

1 1

COORD. W/ MEP DWGS. RECESS FLOOR DRAIN INTO FLOOR, G.C. TO TRENCH AS REQUIRED

STAMP HERE:

SCALE: 1" = 1'-0"

ENLARGED RESTROOM PLAN GENERAL NOTES:

DESCRIPTION

1i

ENLARGED ADA RESTROOM PLAN ENLARGED RESTROOM PLAN KEY NOTES:

1. REFER TO FINISH SCHEDULE A-104 FOR FINISH DESCRIPTIONS AND SPECIFICATIONS.

1

LEASE LINE

2. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES.

2

G.C. TO USE WATER-RESISTANT GYP. BOARD AT ALL WET AREAS

3. G.C. & F.C. TO COORDINATE CONSTRUCTION & INSTALLATION MATERIALS, METHODS, AND SCHEDULING OF FIXTURES.

3

G.C. TO PREP ALL WALLS TO RECEIVE NEW PAINT FINISH AND ENSURE LEVEL 4 FINISH, G.C. TO PAINT ALL WALLS PT-01A

4. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS.

4

NEW WALL BASE

5

G.C. TO PREP NEW DOOR AND FRAME FOR NEW PAINT FINISH. REF. DOOR SCHEDULE

5. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP.

6

NEW WALL MOUNTED LAVATORY BY G.C.; EXPOSED PIPES SHALL BE INSULATED TO PROTECT AGAINST CONTACT; NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY; COORDINATE W/ MEP DWGS.

PROJECT NO.: 218231

6. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING. G.C. TO COORDINATE WITH SHOP DRAWINGS TO BE PROVIDED BY THE FIXTURE CONTRACTOR.

7

NEW AUTOMATIC FAUCET G.C.; COORDINATE W/ MEP DWGS.

DATE: 08/20/2018

8

NEW W.C. W/ OPEN-FACE, ELONGATED TOILET SEAT BY G.C.; COORDINATE W/ MEP DWGS.

7. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS.

9

NEW GRAB BARS BY G.C.; COORDINATE INSTALL WITH NEW WALL FINISH; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQUIRED

8. FINISHES TO BE FIRE RATED AS REQUIRED BY STATE/LOCAL BUILDING CODES.

10

NEW G.F.I. DUPLEX MOUNTED @ 48" AFF W/ WHITE COVER PLATE; COORDINATE W/ MEP DRAWINGS

9. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND MILLWORK. COORDINATE CONSTRUCTION DETAILS AND DIMENSIONS WITH FIXTURE PLANS AND FIXTURE SHOP DRAWINGS.

11

NEW FIXED MIRROR; SURFACE MOUNTED & CENTERED ABOVE LAVATORY BY G.C.; REFLECTIVE SURFACE (NOT FRAME) TO BE MOUNTED AT 40" AFF MAX; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D

10. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.

12

NEW RECESSED PAPER TOWEL DISPENSER BY G.C.; PROVIDE CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D

11. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS.

13

NEW SWITCH / OCCUPANCY SENSOR MOUNTED W/ WHITE COVER PLATE @ 46" AFF; COORDINATE W/ MEP DRAWINGS

12. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES.

14

NEW TILE UP TO 48" MIN. AFF IN RESTROOM; REF. ELEVATIONS

15

G.C. TO PROVIDE WHITE P.TRAP INSULATED COVER TO PROTECT AGAINST CONTACT

B-03

AT RESTROOM FURNISHED BY F.C., INSTALLED BY G.C. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

ENLARGED ADA RESTROOM PLAN AND ELEVATIONS

A-307.00 SHEET 21 OF 27


ARCHITECT OF RECORD:

PARITION FRAMING SCHEDULE NOTES 5 A-500

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1. ALL LT.GA. METAL STUD WALLS AND PARTITIONS REQUIRED GYPSUM BOARD ON BOTH SIDES FOR THE FULL HEIGHT OF THE STUDS (UNLESS SPECIFICALLY DETAILED OTHERWISE). 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. MINIMUM OF 3 TIGHT TURNS AT ALL WIRES.

EXISTING CEILING; G.C. TO ENSURE MAINTENANCE OF FIRE RATING AND FIRE PROTECTION

3 5/8" LT.GA. METAL STUD FRAMING; COORDINATE W/ FRAMING SCHEDULE

HEAVY DUTY SUSPENDED MAIN BEAM @ 4'-0" O.C.

2. ALL SUSPENDED WALLS SHALL HAVE GWB THAT EXTENDS AT LEAST 4 INCHES ABOVE THE SUSPENDED CEILING (UNLESS SPECIFICALLY DETAILED OTHERWISE). 3. ALL STUD WALLS AND PARTITIONS SHALL HAVE CONTINUOUS LINES OF BRIDGING SPACED AT 4'-0" ON-CENTER. THE BRIDGING SHALL BE SECURELY FASTENED TO THE STUDS WITH EITHER WELDS OR SCREWS.

MEP ENGINEER:

4. ALL STUDS SHALL BE 'C'-TYPE WITH FLANGE STIFFENERS. HEAVY DUTY SUSPENDED CROSS TEE @ 2'-0" O.C.

3 5/8" 18 GA. METAL STUD BRACING @ 8'-0" O.C. EACH DIRECTION; LENGTH OF BRACING MAY NOT EXCEED 16'-0"

1 1/2" X 3" 16 GA. CHANNEL CUP ANGLE, FASTEN TO STUD & CHANNEL W/ (4) 5/8" #5-12 SCREWS. ALT FASTENING: (3) 3/4" WELDS (AT 3 DIFFERENT PLACES)

SUSPENDED CEILING FRAMING LAYOUT - GENERAL NOTES

X R MA TE 8" IME R PE AT

8 A-500

FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS.

5/8" THK. TYPE 'X' GWB W/ FINISH AS PER FINISH SCHEDULE

2" MIN WALL MOLDING GRID MEMBERS ATTACHED TO WALL MOLDING @ 2 ADJACENT WALLS USING POP RIVETS OR SCREWS

3/4" 18 GA. COLD ROLLED CHANNEL BRACING SPACED @ 4'-0" O.C. HORIZONTALLY, TYPICAL

5/8" GYP. BD. NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05

BOTTOM TRACK W/ 'HILTI' PNEUMATIC SHOT PINS, .145"Ø W/ DISCS @ 16" O.C., TYPICAL EXISTING FLOOR SLAB

A STEEL STUDS TO STEEL STUDS OR TRACKS: #8-18 X 1/2" TEKS/2 WITH PHIL. PAN-HEAD FOR 25 GA. OR 20 GA. #10-16 X 9/16" TECKS'3 WITH PHIL PAN-HEAD FOR INTERCONNECTION OF 18 GA. OR 16 GA. B. STEEL STUDS OR TRACKS TO WOOD PURLINS, GIRDERS, AND BEAMS: #14-10 X 1/2" H.W.H. TYPE 'S' METAL-TO-WOOD TEKS C. STEEL STUDS OR TRACKS TO STRUCTURAL STEEL (WIDE FLANGE BEAMS, COLUMNS, GURDERS, STEEL TUBE SHAPES, ETC): TEKS/3 OR TEKS/4 GAUGE AND LENGTH AS REQUIRED FOR THE COMBINED THICKNESS OF THE MATERIAL TO BE DRILLED D. PLYWOOD TO STEEL STUDS: #10-24 X 3/4" TEKS/3 (PLYMETAL TEKS) WITH THIN WAFER HEAD.

TYPICAL CEILING FRAMING LAYOUT DIAGRAM; N.T.S.

HEIGHT

ATTACHMENT TO STRUCTURAL SUPPORT TO COMPLY W/ LOCAL CODE 1/2" THIN WALL ELEC. CONDUIT OR APPROVED EQ. (EXTEND TUBE TO BE TIGHT TO CLG. GRID & STRUCTURE ABOVE. THEN INSTALL BOLT TO SECURE ON TO THE OTHER.)

COMPRESSION STRUT 12'-0" MAX. SPACING

DRILL 3/32" HOLE AND INSTALL 1/8" BOLT AND LOCKING NUT

FOUR 12 GA. SPLAY WIRES AT 45 DEGREES PARALLEL TO CROSS TEES

3/4" THIN WALL ELECT. CONDUIT W.SLOT AT END TO FIT OVER CLG. RUNNER. STRUTS TO BE 12'-0" ON CENTERS EACH DIRECTION 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES.

LOCKING CROSS TEES AT 4'-0" O.C. TYP

45

2"

CROSSPIECE, 2'-0" O.C.

TYP. HANGER WIRES AT 4'-0" O.C.

COMPRESSION STRUT DETAIL DIAGRAM; N.T.S.

4

8" MAX

COMPRESSION STRUT DETAIL DIAGRAM; N.T.S.

5

3 5/8" X 18 GA DL

16'-0" - 20'-0"

6" X 18 GA

6" X 18 GA

6" X 18 GA

6" X 18 GA

20'-0" - 24'-0"

6" X 18 GA

6" X 18 GA

6" X 18 GA

6" X 18 GA DL

BRACE AT STRUCTURE DIAGRAM; N.T.S.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP 2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING

(4) 2" TEK SCREWS AT EACH BOTTOM FLANGE

AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

STEEL STUD TRACK

2" 5_ " GWB CEILING 8

6" MIN.

5/8" GWB CEILING

METAL FURRING CHANNEL CLIP

UN-ATTACHED GYPBOARD CEILING

NOTE: 1. THE WIDTH OF THE PERIMETER SUPPORTING ANGLE SHALL BE 2" MIN. 2. THE CLEARANCE FROM THE GRID TO THE WALL AT THE FREE END SHALL BE 3/4" MIN. 3. THE ENDS OF THE MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT THEIR SPREADING

TYPICAL GYP. BD. CEILING WALL CONNECTION DIAGRAM; N.T.S.

3 5/8" X 18 GA

METAL STUD BRACING TO TOP CHORD OF STRUCT. @ 8'-0" O.C. MAX STAGGERED

MAX. SPACING

3/4"

6

3 5/8" X 18 GA

4" X 4" STUD WIDTH X 20 GA. CLIP ANGLES - FASTEN TO EACH BRACE AND RUNNER W/ TEK SCREWS (3 PER LEG TYP.)

24" O.C.

ATTACHED GYPBOARD CEILING

3 5/8" X 18 GA

STAMP HERE:

8" MAX

SUPPORTING ANGLE

5_ " GWB CEILING 8

UP TO 16'-0"

NOTE: MECHANICAL AND LIGHT FIXTURES MUST BE CONNECTED TO ONE (1) VERTICAL 12 GA. WIRE ATTACHED TO OPPOSING CORNERS ALONG THE FIXTURES DIAGONAL. THESE WIRES MAY BE SLACK (UBC STD. NO. 25.213, 25.214)

CEILING HANGER: 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EACH WAY AND MAX 8" FROM ALL EDGES

16 GA. CRC MAIN BEAM @ 4'-0" O.C

2"

NOT APPLICABLE

1 1\2" CHANNEL 4'-0" O.C.MAX.

CEILING HANGER: 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EACH WAY AND MAX 8" FROM ALL EDGES

16 GA. CRC MAIN BEAM @ 4'-0" O.C

2 1/2" X 18 GA

TYP. STUD WALL BRACING

THE ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT SPREADING

CEILING HANGER: 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EACH WAY AND MAX 8" FROM ALL EDGES

2 1/2" X 18 GA

MAIN BEAMS 4'-0" O.C.

MAIN TEES AT 4'-0" O.C.

THE ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT SPREADING

2 1/2" X 18 GA

4" X 4" X 20 GA. CLIP ANGLE, AT EA. BRACE PROVIDE RAMSET PIN FASTENERS (1" IMBED)

2"

MA X

11'-0" SPAN

AS NOTED

EXISTING STRUCTURE

5/8" TYPE 'X' GYPSUM BOARD MA X

8'-0" SPAN

45

45

INSTALL COMPRESSION STRUT AS REQ'D BY CODE 12 QA. VERT WIRE HANGER IN TUBING, LEVEL CEILING PRIOR TO SETTING STRUT

TOP TRACK

BOTTOM TRACK

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

2

TYPICAL 12 GA. HANGER WIRE SET IN CONCRETE SLAB ABOVE COMPRESSION STRUT PER S.F. GENERAL APPROVAL 301 R 28-2

SUPPORTING ANGLE

TYPICAL FASTENERS:

45. 0°

DETAIL AT METAL FRAMING BRACING FOR WALL PARTITIONS DIAGRAM; N.T.S.

ANGLE CLIP- PINNED AND BOLTED TO VERTICAL COMPRESSION BRACE

3

6. GC TO COORDINATE ANY AND ALL REQUIRED SPECIAL INSPECTIONS OF CEILING AND PARTITION FRAMING WITH LOCAL BUILDING CODE OFFICIAL

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

E. GYPSUM BOARD TO STEEL STUDS: #7 X 1/4" TYPE 'S' BUGLE HEAD SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 25 GA. OR 20 GA. METAL STUDS. #6 X 1/4" TYPE 'S-12' BUGLE HEAD SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 18 GA. OR 16 GA. METAL STUDS OR TRACKS.

4" MIN.

1

C L

MAX WEIGHT = 40 LBS PER HANG POINT

45

3/4" X 16 GA. COLD-ROLLED CHANNEL; SPACING @ 4'-0" O.C. IN HORIZONTAL DIRECTION

4'-0" O.C. HORIZONTALLY, TYP.

3 5/8" 18 GA. METAL STUD FRAMING MEMBERS @ 16" O.C.

5. THE MATERIALS AND DETAILS SHOWN ARE FOR TYPICAL INSTALLATIONS. WHERE THE STUD MANUFACTURER RECOMMENDS OR LOCAL ORDINANCES AND/OR CODES ARE MORE RESTRICTIVE OR HIGHER STANDARDS, THESE SHALL PREVAIL AND APPLY.

CEILING AS SCHEDULED SEE SCHEDULED PARTITION TYPE

7

TYPICAL SUSPENDED GYP. BD. CEILING DIAGRAM; N.T.S.

8

WALL BRACING CONNECTION DIAGRAM; N.T.S.

CEILING CONSTRUCTION DETAILS

A-500.00 SHEET 22 OF 27


ARCHITECT OF RECORD:

2' - 8 1/2" WRAP COLOR CORE LAMINATE AT CORNER

EXISTING STOREFRONT AND GLAZING TO REMAIN.

2' - 3 1/2"

3" 1 1/2"

3/4" THK PAINT GRADE MDF W/ COLOR CORE LAMINATE (WHITE)

1/2"

2' - 5" A.F.F. T.O. PLATFORM

3/4"

PAINTED WOOD BASE SCRIBE BASE TO FLOOR B-01 PT-01B

LIGHT SHIELD CONTINUOUS ALONG SLOT EXCEPT AT PLENUM BOX LOCATIONS

6" METAL STUD, SPACED AT 16" O.C. TYP

R-19 BATTING INSULATION

5/8" TYPE 'X' GYP. BOARD

3/4" THK PAINT GRADE MDF 2' - 5"

RUBBER STANDOFF; FINISH TO MATCH ADJ WALL

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

2' - 3 3/4"

1/2"

MEP ENGINEER:

BLOCKING AS REQ'D PAINTED BLACK

BRASS TRANSITION BY G.C. 7 1/4"

PLENUM BOX BEYOND; REF. MEP DRAWINGS

SLOTTED GRILL BY G.C.

WOOD BLOCKING AS REQ'D

ATTACHMENT CLIPS AS REQUIRED

3 5/8" METAL FRAMED PLATFORM BY G.C.

NEW RADIATOR TO; REF. PLANS AND MEP DWGS. FOR SPEC INFO AND LOCATIONS

COUNTERSUNK SCREW FINISH TO MATCH ADJ.

5/8" GYP. BOARD AT CEILING PT-01C

1/2" CONT. REVEAL ALONG BASE

REF. RCP 1/2"

1/2"

1/4"

0' - 0" A.F.F. FINISHED FLOOR

3 1/4"

1/4"

DUCT BEYOND; REF. MEP DRAWINGS

1/2" CONT. REVEAL ON TOP PANEL

ALIGN

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

6"

1"

HOLD

SLOT

B.O. CEILING TAPE AND SANDED PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED 1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS

HEAD & JAMP TRANSITION DETAIL

9

SCALE: 3" = 1'-0"

STOREFRONT DISPLAY PLATFORM

3

SCALE: 1 1/2" = 1'-0"

TAPED-IN LINEAR SLOT DETAIL SCALE: 3" = 1'-0"

EXISTING SLAB ABOVE TO REMAIN

EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTEN TO DEEP FLUTE OF EXISTING STRUCTURE ONLY AND COMPLY WITH LANDLORD AND BUILDING ANCHORING REQUIREMENTS, TYP.

EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTEN TO DEEP FLUTE OF EXISTING STRUCTURE ONLY AND COMPLY WITH LANDLORD AND BUILDING ANCHORING REQUIREMENTS, TYP.

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.

SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX.

EXISTING SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

1/4"Ø GALVANIZED LEVELING ROD, CONNECTED TO SPRING HANGER PER MANUFACTURER'S SPECIFICATIONS AT MAX. SPACING OF 4'-6" O.C.

1/4"Ø GALVANIZED LEVELING ROD, CONNECTED TO SPRING HANGER PER MANUFACTURER'S SPECIFICATIONS AT MAX. SPACING OF 4'-6" O.C.

NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PENETRATION, TYP.

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.

G.C. TO PROVIDE 3/4"THK CONTINUOUS FRT PLYWOOD BLOCKING ABOVE LIGHT COVE ANCHOR BOLT

ANCHOR BOLT

SURFACE MOUNTED LIGHT TRACK, REF. A-102 REFLECTED CEILING PLAN

NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIR-TIGHT AT TOP OF PARTITION

1/2"THK KINETICS WALLMAT RESILIENT PARTITION ISOLATION STRIP

3/8"THK KINETICS SRP PERIMETER ISOLATION BOARD

1/2"THK KINETICS WALLMAT RESILIENT PARTITION ISOLATION STRIP KINETICS KAI-S ANCHOR ISOLATOR BRUSHING ASSEMBLY W/ FENDOR WASHER, NEOPRENE ISOLATOR, AND CARBON STEEL SPACER

EXISTING CEILING V.I.F.

(2) LAYERS 5/8"THK TYPE 'X' GYP. BOARD AT LIGHT COVE; FINISH TO MATCH PT-01C

KINETICS KAI-S ANCHOR ISOLATOR BRUSHING ASSEMBLY W/ FENDOR WASHER, NEOPRENE ISOLATOR, AND CARBON STEEL SPACER

13' - 3 3/4" A.F.F. LIGHT COVE

5"

FIBERGLASS BATT, SPONGER NEOPRENE OR RUBBER SLEEVE AT PENETRATION, TYP.

13' - 1 1/4" A.F.F. B.O. OVERHANG

HOLD

MAINTAIN ACOUSTIC RATING AT LANDLORD'S EXISTING CEILING, TYP.

12' - 10 3/4" A.F.F.

SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX.

ALIGN

MAINTAIN ACOUSTIC RATING AT LANDLORD'S EXISTING CEILING, TYP.

7/8" FURRING CHANNELS AT RIGHT ANGLE TO COLD-ROLLED CHANNELS SPACED AT 2'-0" O.C. MAX.

VARIES

NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PENETRATION, TYP.

6"

6"

4"

5"

3"

HOLD

HOLD

HOLD

HOLD

HOLD

12' - 8" A.F.F. FR LOUNGE T.O. ARCH EXISTING STOREFRONT SYSTEM TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PERIMETER, TYP.

ATTACHMENT CLIPS AS REQUIRED VARIES

TAPE AND SANDED PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED

SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX.

1' - 10 3/4"

EQ.

3"

PLENUM BOX BEYOND; REF. MEP DRAWINGS

EQ.

1' - 0"

3"

EQ.

6"

3 3/4"

EQ.

6"

LED TAPE LIGHTING WITH ANGLE CHANNEL, CLIP. MOUNTED ON GYP. B.D (TL-1)

LOUNGE

8"

1 1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS AT SPACED 4'-0" O.C. MAX. 7/8" FURRING CHANNELS AT RIGHT ANGLE TO COLD-ROLLED CHANNELS SPACED AT 2'-0" O.C. MAX.

G.C. TO PROVIDE 3/4"THK IN-CEILING CONTINUOUS FRT PLYWOOD BLOCKING ABOVE WINDOW DISPLAY CEILING

3. NO RIGID CONNECTION BETWEEN ISOLATED CEILING, COLUMNS, DUCTWORK, WALLS OR PERIMETER FASCIA AT STOREFRONT, USE KINETICS SRP PERIMETER ISOLATION BOARD AND SEAL WITH NONHARDENING, RESILIENT ACOUSTIC CAULKING, TYP.

1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS

(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT SALES CEILING; FINISH TO MATCH PT-01C

7

STOREFRONT LIGHT COVE DETAIL SCALE: 3" = 1'-0"

1"

6"

HOLD

HOLD

TAPE AND SANDED PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED

11' - 0" A.F.F. SALES CEILING VARIES REF. RCP

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

2. G.C. TO CONFIRM BATT INSTALLATION INSTALLED ABOVE LANDLORD'S (2) LAYER GYP. BOARD CEILING

ATTACHMENT CLIPS AS REQUIRED

DUCT BEYOND; REF. MEP DRAWINGS

SCALE: 1 1/2" = 1'-0"

1. NO RIGID CONNECTION TO LANDLORD'S SLAB OR ACOUSTIC CEILING. ANY PENETRATIONS MADE TO LANDLORD'S ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATION AND SEALED WITH FLEXIBLE CAULKING TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS IS REQUIRED IN ADDITION TO THE EXISTING ACCESS PANELS LOCATED WITHIN THE SPACE, G.C. IS TO OPEN AS REQUIRED AND THEN PATCH BACK WITH (2) LAYERS OF 5/8"THK TYPE 'X' GYP. BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING

(2) LAYERS 5/8"THK TYPE 'X' GYP. BOARD AT WINDOW DISPLAY CEILING FINISH TO MATCH PT-01C

BLOCKING AS REQ'D

(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD; FINISH TO MATCH PT-03

LOUNGE CEILING DROP DETAIL

NOTES:

ARAKAWA MERCHANDISING TRACKS MODEL CRB 1800A, RECESSED INTO GWB CEILING, POWDER-COATED TO MATCH ADJ. FINISH PT-01C

LIGHT SHIELD CONTINUOUS ALONG SLOT EXCEPT AT PLENUM BOX LOCATIONS

BLOCKING AS REQ'D

1 5/8"

HOLD

PLENUM BOX BEYOND; REF. MEP DRAWINGS

10' - 0" A.F.F.

10

8"

(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT DISPLAY WINDOW SOFFIT WALL; FINISH TO MATCH PT-01A

1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS

LOUNGE POP-UP

STAMP HERE:

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. & WINDOW DISPLAY CEILING

1 1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS AT SPACED 4'-0" O.C. MAX.

10' - 10" A.F.F.

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

12

CONSTRUCTION AND CEILING DETAILS

5"

A-501.00 SHEET 23 OF 27


ARCHITECT OF RECORD:

METAL STUD BRACING TO STRUCTURE AT 8'-0" OC MAX STAGGERED EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTENING TO DEEP FLUTE OF EXG STRUCTURE ONLY AND TO COMPLY WITH LANDLORD AND LOCAL BUILDING REQUIREMENTS. TYP.

ANCHOR BOLT. MODEL WALLMAT (BY KNC)

5/8" TYPE 'X' GYP BOARD

4" X 4" STUD WIDTH X 20 GA CLIP ANGLES; FASTEN TO EACH BRACE AND RUNNER WITH TEK SCREWS (3 PER LEG, TYP)

MEP ENGINEER:

4 X 2" TEK SCREWS AT EACH BOTTOM FLANGE

MODEL WALLMAT (BY KNC)

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

MODEL KAI-S ANCHOR ISOLATOR BUSHING ASSEMBLY (BY KNC) INCLUDES:  FENDER WASHER  NEOPRENE ELEMENT  CARBON STEEL SPACER

METAL STUD BRACING SECURE TO ANGLE CLIP.

STEEL STUD TRACK 6" MIN

MODEL KAI-S ANCHOR ISOLATOR BUSHING ASSEMBLY (BY KNC) INCLUDES:  FENDER WASHER  NEOPRENE ELEMENT  CARBON STEEL SPACER

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

ANGLE CLIP. TYP.

METAL CHANNEL; SEE A-101.00 FOR SPEC.

SUSPENDED CEILING PROVIDE EDGE BEAD; TAPE AND SPACKLE

METAL STUD; SEE A-101.00 FOR SPEC.

12

TYPICAL PARTITION AT CORNER

5/8"THK GYP BOARD

9

SCALE: 3" = 1'-0"

TYPICAL SOUND ISOLATION CONNECTION

6

SCALE: 3" = 1'-0"

TYPICAL SOUND ISOLATION BRACING CONNECTION

3

SCALE: 3" = 1'-0"

TYPICAL BRACING CONNECTION SCALE: 3" = 1'-0"

ANCHOR BOLT. MODEL WALLMAT (BY KNC)

ACOUSTICAL CAULKING. MODEL KAI-S ANCHOR ISOLATOR BUSHING ASSEMBLY (BY KNC) INCLUDES:  FENDER WASHER  NEOPRENE ELEMENT  CARBON STEEL SPACER METAL CHANNEL; SEE A-101.00 FOR SPEC.

EXISTING SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTEN TO DEEP FLUTE OF EXISTING STRUCTURE ONLY AND COMPLY WITH LANDLORD AND BUILDING ANCHORING REQUIREMENTS, TYP.

EXISTING SLAB ABOVE TO REMAIN

14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.

1/4"Ø GALVANIZED LEVELING ROD, CONNECTED TO SPRING HANGER PER MANUFACTURER'S SPECIFICATIONS AT MAX. SPACING OF 4'-6" O.C.

ANCHOR BOLT KINETICS KAI-S ANCHOR ISOLATOR BRUSHING ASSEMBLY W/ FENDOR WASHER, NEOPRENE ISOLATOR, AND CARBON STEEL SPACER

METAL STUD; SEE SEE A-101.00 FOR SPEC.

1/2"THK KINETICS WALLMAT RESILIENT PARTITION ISOLATION STRIP

2 3/4"

DIM PER WALL TYPE 5/8" TYPE 'X' GYP BOARD METAL CHANNEL; SEE A-101.00 FOR SPEC.

MAINTAIN ACOUSTIC RATING AT LANDLORD'S EXISTING CEILING, TYP. FIBERGLASS BATT, SPONGER NEOPRENE OR RUBBER SLEEVE AT PENETRATION, TYP.

FLOOR

3 5/8" METAL STUD FRAMING EXTEND TO EXISTING CEILING ABOVE

TYPICAL PARTITION

STAMP HERE:

SCALE: 3" = 1'-0"

ROY WILLIAMS VIBRATION PRODUCTS A KETCHUM & WALTON CO. 560 SYLVAN AVE. ENGLEWOOD CLIFFS, NJ 07632 P: 201-569-7400 F: 201-569-7417 CELL: 330-352-1273

R

15'-1" A.F.F. V.I.F. EXISTING CONCRETE SLAB

EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTENING TO DEEP FLUTE OF EXG STRUCTURE ONLY AND TO COMPLY WITH LANDLORD AND LOCAL BUILDING REQUIREMENTS. TYP. 1_ " GALVANIZED LEVELING RODS 4 ASSEMBLY TO SPRING HANGER. PER MANUFACTURER SPEC. FASTENING AT MAXIMUM OF 4'-6" O.C.

13'-1" A.F.F. V.I.F. EXISTING LL'S FIN. CEILING

MAINTAIN EXISTING LL'S ACOUSTICAL CEILING RATING.

KINETIC MODEL SRP 3_8" THICK PERIMETER ISOLATION.

NON-HARDENING, RESILIENT CAULKING SEALED AIR TIGHT AT PERIMETER. TYP.

RESILIENT ACOUSTICAL CAULKING.

SOUND ISOLATED DECK SUSPENDED CEILING HANGER. 4' X 4' O.C. MAXIMUM.

KINETICS R

KINETICS R

7_ " FURRING CHANNELS 8

AT RIGHT ANGLE TO COLD ROLLED CHANNEL AND SPACED AT 2'-0" O.C. 1-1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS WEIGHING 0.457 POUNDS PER LINEAR FOOT AT 4'-0" O.C.

11'-6" A.F.F. FINISHED CEILING

8" MAX TO FIRST SUPPORT AT PERIMETER

KINETIC MODEL SRP 3_8" THICK PERIMETER ISOLATION.

5/8" PAINTED GYP BOARD

RESILIENT ACOUSTICAL CAULKING.

FACE OF WALL NOTE: NO RIGID CONNECTION BETWEEN ISOLATED CEILING AND COLUMNS, DUCTWORK, WALLS OR PERIMETER FASCIA. USE KINETICS SRP AND FINISH WITH FLEXIBLE/NON-HARDENING SEALANT. NOTE: GC TO CONFIRM BATT INSULATION INSTALLED ABOVE LANDLORD'S TWO LAYER GYPSUM BOARD CEILING IN FIELD.

NOTE: FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND/OR LOCAL BUILDING DEPARTMENT REQUIREMENTS. SOUND ISOLATIOR, & VIBRATION ELIMINATOR ARE REQUIRED FOR ALL CEILING HUNG EQUIPMENT. NOTE: REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS

TYPICAL DRYWALL CEILING SCALE: 1 1/2" = 1'-0"

SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX. 6"

NO CONTACT AT COLD ROLLED CHANNEL

1 1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS AT SPACED 4'-0" O.C. MAX. 7/8" FURRING CHANNELS AT RIGHT ANGLE TO COLD-ROLLED CHANNELS SPACED AT 2'-0" O.C. MAX. (1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT FR CEILING; FINISH TO MATCH PT-01C

PROJECT NO.: 218231 DATE: 08/20/2018

SUSPENDED DECORATIVE LIGHTS

(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT FLAT PORTIONS OF FITTING ROOM LOUNGE WALLS; FINISH TO MATCH PT-03

3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. NOTE: RESILIENT ACOUSTICAL CAULKING IS REQUIRED AT ALL PERIMETERS WHERE WALL AND CEILING MEETS .

ENLARGED SECTION AT FITTING ROOM LOUNGE CEILING

DRAWN BY: GR, RE, NK 9' - 0" A.F.F. 9' - 0" A.F.F. FITTINGFR ROOM LOUNGE CEILING TRANSITION

G.C. TO TAPE AND PLASTER TO CONCEAL SEAM BETWEEN WALLS AND ARCHED CEILING, TYP.

2 1/2" METAL STUD FRAMING SPACED AT 16" O.C.

SCALE: 1 1/2" = 1'-0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

1/8"THK HAND TROWELED PLASTER FINISH OVER 2 LAYERS 1/4"THK GYP.. BOARD AT FITTING ROOM LOUNGE ARCH; G.C. TO ENSURE LEVEL 4 SMOOTH FINISH TO MATCH WALLS AND PAINT PT-03

(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT FR WALLS; EXTEND TO 6" ABOVE CEILING LEVEL; FINISH TO MATCH PT-01A

7

0"

7/8"THK FURRING CHANNELS SPACED AT 16" O.C. TO FORM CEILING ARCH

KINETICS R

FIBER GLASS BATT, SPONGE NEOPRENE OR RUBBER SLEEVE AT PERIMETER. TYP.

4' -

6"

KINETICS

R

3 5/8" METAL STUD FRAMING SECURED AT EITHER END OF THE ROOM AND BRACED BACK TO SIDE WALL FRAMING AS REQ'D, TYP.

4"

EXISTING LL'S ACOUSTICAL SUSPENDED HANGER. TYP.

11' - 0" A.F.F. LOUNGE POP-UP

3' - 8"

ACOUSTICAL CEILING SYSTEM VENDOR'S CONTACT: GC TO COORDINATE FOR REQUIREMENTS, SPECIFICATION FOR PRICING.

NOTE: NO HARD CONNECTION TO LL’S SLAB OR ACOUSTIC CEILING. ANY PENETRATIONS MADE TO LL’S ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATIONS AND SEAL WITH FLEXIBLE CAULKS TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS REQUIRED IN ADDITION TO THE ACCESS PANEL ALLOCATED IN SPACE, GC IS TO MAKE THE CONNECTION AND THEN PATCH BACK IN WITH TWO LAYERS OF TYPE ‘X’ GYPSUM BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING.

10

12' - 8" A.F.F. FR LOUNGE T.O. ARCH

(2) LAYERS 3/8" FRT PLYWOOD BLOCKING TO SECURE DECORATIVE SUSPENDED LIGHTING

NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PENETRATION, TYP.

SEALANT

12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. CONCEALED J-BOX FOR SUSPENDED DECORATIVE LIGHTING

BASE AS SCHEDULED

11

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

FINISHED CEILING

4' - 0"

4' - 0" 8' - 0"

CHECKED BY: JSP AREA: 1807 SQ.FT

NOTES:

#

ISSUE

DATE

1. NO RIGID CONNECTION TO LANDLORD'S SLAB OR ACOUSTIC CEILING. ANY PENETRATIONS MADE TO LANDLORD'S ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATION AND SEALED WITH FLEXIBLE CAULKING TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS IS REQUIRED IN ADDITION TO THE EXISTING ACCESS PANELS LOCATED WITHIN THE SPACE, G.C. IS TO OPEN AS REQUIRED AND THEN PATCH BACK WITH (2) LAYERS OF 5/8"THK TYPE 'X' GYP. BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING

1

ISSUE FOR PERMIT

09/07/2018

2. G.C. TO CONFIRM BATT INSTALLATION INSTALLED ABOVE LANDLORD'S (2) LAYER GYP. BOARD CEILING 3. NO RIGID CONNECTION BETWEEN ISOLATED CEILING, COLUMNS, DUCTWORK, WALLS OR PERIMETER FASCIA AT STOREFRONT, USE KINETICS SRP PERIMETER ISOLATION BOARD AND SEAL WITH NONHARDENING, RESILIENT ACOUSTIC CAULKING, TYP.

CONSTRUCTION AND CEILING DETAILS

A-502.00 SHEET 24 OF 27


ARCHITECT OF RECORD:

VARIES

EXISTING V.I.F.

NEW FINISHED FLOOR AS SCHEDULED 0' - 0" A.F.F. 4 7/8"

FINISHED FLOOR NOTE: BASE AS SCHEDULED

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE • (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD AT CEILING EXTEND GYP. BOARD 6" ABOVE CEILING AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES

VARIES REF. RCP

2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY

B

NEW FINISHED FLOOR AS SCHEDULED

NEW FINISHED FLOOR AS SCHEDULED

0' - 0" A.F.F.

0' - 0" A.F.F.

FINISHED FLOOR

FINISHED FLOOR 4 1/4"

NOTE: BASE AS SCHEDULED

WALL TYPE "B" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT •

C

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING

WALL TYPE "C" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT •

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

D

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS EXTEND GYP. BOARD 6" ABOVE CEILING

NEW FINISHED FLOOR AS SCHEDULED

0' - 0" A.F.F.

0' - 0" A.F.F.

FINISHED FLOOR

FINISHED FLOOR 4 7/8"

NOTE: BASE AS SCHEDULED

E

6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING

WALL TYPE "E" - INTERIOR NON-LOAD BEARING PARTITION - PLUMBING •

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

CONTINUOUS METAL TRACK

NEW FINISHED FLOOR AS SCHEDULED

NOTE: BASE AS SCHEDULED

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP

CONTINUOUS METAL TRACK

WALL TYPE "D" - INTERIOR NON-LOAD BEARING PARTITION •

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE

6" METAL STUD, SPACED AT 16" O.C. TYP

FINISHED FLOOR 7 1/4"

T.O. PARTIAL HEIGHT WALL

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY (USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS, REF. PLAN)

6" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK NEW FINISHED FLOOR AS SCHEDULED 0' - 0" A.F.F.

NOTE: BASE AS SCHEDULED

MEP ENGINEER:

9' - 0" A.F.F.

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD AT TOP; FINISH TO MATCH ADJ. WALL FINISH

B.O. CEILING

B.O. CEILING 2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP (1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE

3 5/8" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK

UNDERSIDE OF FINISHED CEILING, REFER TO RCP

VARIES REF. RCP

VARIES REF. RCP

B.O. CEILING

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE; EXTEND GYP. BOARD TO DECK ABOVE AT LOCATION'S WITH NO CEILING, TYP.; REF. RCP 3 5/8" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK

BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

B.O. EXG CLG

F

6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS EXTEND GYP. BOARD 6" ABOVE CEILING USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS

NOTE: BASE AS SCHEDULED

WALL TYPE "F" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT • •

3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD PROVIDE GYP. BOARD AT TOP OF PARTIAL HEIGHT PARTITION AND FINISH TOP OF PARTITION TO MATCH WALL FINISH

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

VARIES REF. RCP

WALL TYPE "A" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT

BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES

B.O. CEILING

B.O. CEILING

A

BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES VARIES REF. RCP

2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING

4 7/8"

SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

. 6"

B.O. EXISTING CEILING

UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP

SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

. 6"

VARIES REF. RCP

SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

6" .

SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.

. 6"

. 6"

B.O. DECK UNDERSIDE OF EXISTING DECK

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

1/2" SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP. EXISTING V.I.F.

REF. A-100 FOR PARTITION TYPE 4" TALL RUBBER WALL BASE, SCARIFY SURFACE BEHIND BASE ONLY PRIOR TO INSTALLATION B-02

B.O. DECK UNDERSIDE OF EXISTING DECK

BOH

VARIES REF. RCP

4"

7"

. 6"

6"

NEW FLOOR FINISH AS SCHEDULED; REF. A-104

B.O. CEILING 2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP 1"

(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE

SCRIBE

STAMP HERE:

B-01

6" METAL STUD, SPACED AT 16" O.C. TYP

PAINTED WOOD TRIM FOR WALL BASE BY G.C.

CONTINUOUS METAL TRACK NEW FINISHED FLOOR AS SCHEDULED

5

0' - 0" A.F.F.

TRIM PROFILES SCALE: 6" = 1'-0"

2

B-02 WALL BASE 02 SCALE: 3" = 1'-0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

FINISHED FLOOR

D

3/4"THK PLYWOOD SUBFLOOR

WALL TYPE "G" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT • •

6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING

REF. A-104 FOR TRANSITION FINISHES

TILE COVE BASE B-03

WALL BASE AS SCHEDULED; REF. A-104 FLOOR FINISH PLAN

RESTROOM

NEW 5/8"THK GLUE DOWN WOOD FLOOR WHERE SCHEDULED; REF. A-104 FLOOR FINISH PLAN

NEW TILE FLOOR AS SCHEDULED; REF. A-104 T-01 CONTINUOUS VAPOR BARRIER

WOOD SLEEPERS SPACED @ 24" O.C. EXISTING CONCRETE SLAB, G.C. TO PREP FOR NEW FLOOR FINISHES AS SCHEDULED C-EXG

DATE: 08/20/2018

REF. A-100 FOR PARTITION TYPE

1/2"

PAINTED WOOD BASE SCRIBE BASE TO FLOOR B-01 PT-01B

CHECKED BY: JSP AREA: 1807 SQ.FT

SALES

NEW FLOOR FINISH AS SCHEDULED; REF. A-104

EXISTING CONCRETE SLAB TO REMAIN

PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN

16

SCALE: 1 1/2" = 1'-0"

7

THRESHOLD I SCALE: 3" = 1'-0"

4

B-03 WALL BASE 03 SCALE: 3" = 1'-0"

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

PARTITION, TRIM, AND THRESHOLD DETAILS

NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.

PARTITION TYPES

DRAWN BY: GR, RE, NK

6"

VARIES

ALIGN

NEW 1/8"THK SCHULTER SCHIENE M-100 BRASS TRANSITION STRIP

NEW PORCELAIN WALL TILE W/ BULLNOSE TRIM T-02

1"

SCRIBE PLANK TO CONCRETE AT TRANSITION EDGE

EDGE OF STOREFRONT DISPLAY PLATFORM; REF A-501 FOR DETAIL

PROJECT NO.: 218231

7"

TRANSITION

REF. A-100 FOR PARTITION TYPE

6"

EDGE OF TRANSITION

4'-0" MIN.

7 1/4"

1

B-01 WALL BASE 01 SCALE: 3" = 1'-0"

A-600.00 SHEET 25 OF 27


*SEE DOOR SWING DIRECTION ON CONSTRUCTION PLAN, TYP.

--

EX'G

EX'G

7/A-602

--

--

EXISTING DOOR AND HARDWARE TO REMAIN; G.C. TO CLEAN AND PROVIDE NEW BESTLOCKS

1 3/4"

2' - 0 1/4"

1 3/4"

1/16" 2' - 0" 3/16"

F

05

06

3

3'-0"

7'-0"

1 3/4"

4/A-602

HOLLOW METAL

PT-01B

4

3'-0"

7'-0"

1 3/4"

4/A-602

BOH BLIND DOOR

PAINTGRADE WOOD

FITTING ROOM BLIND DOOR

PAINTGRADE WOOD

PT-01A

PT-01A

5

6

2'-0"

2'-0"

7'-0"

7'-0"

1 3/4"

1 3/4"

5/A-602

6/A-602

10/A-602

--

F/I BY G.C.

11/A-602

HOLLOW METAL

PT-01B

11/A-602

--

--

F/I BY G.C.

12/A-602

HOLLOW METAL

PT-01B

12/A-602

--

--

F/I BY G.C.

13/A-602

PAINTGRADE WOOD

15/A-602

PAINTGRADE WOOD

1/8"

PT-01B

PT-01A

PT-01A

13/A-602

15/A-602

--

--

--

F/I BY G.C.; G.C. TO SUBMIT SHOP DRAWINGS FOR APPROVAL

--

F/I BY G.C.; G.C. TO SUBMIT SHOP DRAWINGS FOR APPROVAL

PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN

NEW EDGE PULL AT FITTING ROOM SIDE ONLY

3"

NEW PULL PLATE BOH SIDE ONLY

NEW PULL PLATE AT CLOSET SIDE ONLY

4' - 0"

PT-01B

HOLLOW METAL

5/8"

HOLLOW METAL

10/A-602

1 3/4"

4/A-602

NEW KICK PLATE AT BOH SIDE ONLY

2' - 4 1/4"

E

1 3/4"

3' - 3"

DOOR TO BOH

7'-0"

3' - 3"

04

3'-0"

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

MEP ENGINEER:

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

DOOR

D

2

7' - 0"

03

PT-01B

RESTROOM SIGNAGE AS PER LOCAL CODE REQUIREMENTS

PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR

PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN

CHAMFER WALL BASE AT HINGE SIDE

WALL BASE AS SCHEDULED FITTING ROOM (PULL)

STOREFRONT DISPLAY WINDOW PLATFORM

WALL BASE AS SCHEDULED

5/8"

C

DOOR TO CLOSET

HOLLOW METAL

7' - 0 3/4"

02

DOOR TO RESTROOM

DOOR

PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR

DOOR B

DOOR @ BOH

1/8"

SIGNAGE

1/8" 2' - 0" 1/8"

1/8"

F.R.

1/8" 2' - 0 1/2" 1/8"

1 1/2"

--

THRESHOLD

1 1/2"

7' - 0 3/4"

10'-1" V.I.F.

FINISH

2' - 0 1/4"

7' - 0"

1

1 3/4" V.I.F.

MATERIAL

NOTES *F/I = FURNISH & INSTALL

1 1/2"

5/8"

EX'G

2 LEAVES 3' - 2 1/4" V.I.F.

THK

HEAD DETAIL

1"

DOOR

METAL / GLASS

WIDTH

JAMB DETAIL

1/2"

EX-01

STOREFRONT ENTRY DOOR

FINISH

SIZE HEIGHT

1"

DESCRIPTION MATERIAL

HARDWARE SET

7' - 0"

A REF. A-201

DOOR NO.

REMARKS

7' - 1 1/4"

TYPE DOOR

FRAME

2' - 0 3/4" 1/2"

9' - 6 1/2"

DOOR

ARCHITECT OF RECORD:

1"

DOOR

DOOR SCHEDULE

NEW KICK PLATE AT PUSH SIDE ONLY

EXTEND DISPLAY PLATFORM INTO DOOR OPENING

STOREFRONT DISPLAY WINDOW (PUSH)

BOH (PULL)

DOOR TYPE "F"

DOOR TYPE "E"

DOOR HARDWARE SCHEDULE

MOUNT CLOSER AT BOH SIDE

1/8"

3' - 0"

2" 2" PAINTED HOLLOW METAL DOOR FRAME PT-01B

1/8"

KICK PLATE: (1) IVES 8400 - 10"X34"; NMH-A; FINISH: US4 SATIN BRASS

3' - 0 1/4" 1/8"

PAINTED HOLLOW METAL DOOR

1/8"

DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: 696 SATIN BRASS

2"

DOOR

2"

HINGES: (3 PAIR) EMTEK 96415 4 1/2"x4 1/2"; FINISH: SATIN BRASS US4

3' - 0 1/4"

3' - 0" DOOR

PAINTED HOLLOW METAL DOOR

3"

DOOR

NEW DEADLOCK W/ THUMBTURN AT CLOSET SIDE

3"

DOOR

7' - 0"

7' - 0 3/4"

SILENCERS: (3) IVES SR66; FINISH: WHITE

2" PAINTED HOLLOW METAL DOOR FRAME PT-01B

1/8"

NEW DEADLOCK W/ THUMBTURN AT BOH SIDE

FLOOR STOP: (1) IDH 'LOW PROFILE DOME' STOP 13060; FINISH: 004 SATIN BRASS

MOUNT CLOSER AT CLOSET

2"

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

2"

2"

LEVERSET: (1 SET) SCHLAGE F40 LAT 608, LATITUDE PRIVACY LEVERSET; FINISH: 608 SATIN BRASS

1/8"

NOTE: EXISTING HARDWARE TO REMAIN; G.C. TO PROVIDE NEW BESLOCKS AND 6 SETS OF KEYS

7' - 0"

SET #2 - DOOR TO RESTROOM

7' - 0 3/4"

SET #1 - STOREFRONT ENTRY DOORS

LEVERS: (1) SCHLAGE F170 LAT 608, LATITUDE DUMMY LEVER FINISH: 608 SATIN BRASS

LEVERS: (2) SCHLAGE F170 LAT 622, LATITUDE DUMMY LEVER; FINISH: 622 MATTE BLACK

DEADLOCK: (1 SET) SCHLAGE B560R, ADA COMPLIANT SINGLE CYLINDER WITH INTERCHANGEABLE CORE; PROVIDE 6 SETS OF KEYS FINISH: 606 SATIN BRASS

DEADLOCK: (1 SET) SCHLAGE B560R, ADA COMPLIANT SINGLE CYLINDER WITH INTERCHANGEABLE CORE; PROVIDE 6 SETS OF KEYS FINISH: 606 SATIN BRASS

HINGES: (3 PAIR) EMTEK 96415 4 1/2" x 4 1/2" SQUARE CORNER BRASS HINGES; FINISH: US4 SATIN BRASS

HINGES: (3 PAIR) EMTEK 96415 4 1/2" x 4 1/2" SQUARE CORNER BRASS HINGES; FINISH: US4 SATIN BRASS

DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: 696 SATIN BRASS

DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: 696 SATIN BRASS

KICK PLATE: (1) IVES 8400 - 10" x 34"; NMH-A; FINISH: SATIN BRASS US4

KICK PLATE: (1) IVES 8400 - 10" x 34"; NMH-A; FINISH: SATIN BRASS US4

SILENCERS: (3) IVES SR66; FINISH: WHITE

WALL STOP: (1) IVES WS65 US27; FINISH: ALUMINUM

NEW DUMMY LEVERS BOTH SIDES OF DOOR

BOH (PULL)

3' - 3"

NEW KICK PLATE AT PUSH SIDE ONLY

NEW DUMMY LEVER AT VESTIBULE SIDE ONLY

VESTIBULE (PUSH)

VESTIBULE (PULL)

DOOR TYPE "D"

NEW KICK PLATE AT PUSH SIDE ONLY CLOSET (PUSH)

DOOR TYPE "C"

6' - 5 3/4" 1/8" 2" ADA RESTROOM SIGNAGE, G.C. TO INSTALL PER LOCAL CODE REQUIREMENTS

3' - 0 1/4" 1/8"

3' - 0"

MOUNT CLOSER AT RESTROOM SIDE 2" PAINTED HOLLOW METAL DOOR FRAME PT-01B

2" 1/8"

DOOR

1 1/2"

SET #4 - DOOR TO BOH

3' - 2 5/8" PANEL V.I.F.

1/4"

3' - 2 5/8"

STAMP HERE:

1/8"

PANEL V.I.F.

2"

SET #3 - DOOR TO CLOSET

5/8"

5/8"

3' - 3"

NOTE: KICK PLATE TO BE INSTALLED ON PUSH SIDE ONLY; INSTALL WALL STOP ON VESTIBULE SIDE.

1/8"

PAINTED HOLLOW METAL DOOR

SILENCERS: (3) IVES SR66; FINISH: WHITE

ROLLER CATCH (1) IVES 336-B26 DOOR ROLLER CATCH

KICKPLATE: (1) IVES 8400 - 10" x 22"; NMH-A; FINISH: US32D STAINLESS STEEL

KICK PLATE: (1) IVES 8400 - 10" x 23 1/2"; NMH-A; FINISH: US32D STAINLESS STEEL WALL BUMPER (3) HAFELE 941.60.051 WALL RUBBER BUMPER FINISH: BLACK

NOTE: KICK PLATE AND PULL PLATE TO BE INSTALLED ON BACK OF HOUSE SIDE ONLY

SILENCERS: (3) IVES SR66; FINISH: WHITE

DRAWN BY: GR, RE, NK CHECKED BY: JSP #

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

NEW KICK PLATE AT PUSH SIDE ONLY VESTIBULE (PULL)

(1 PAIR) SOSS INVISIBLE SPRING HINGE #218IC FINISH: WHITE E-COAT ROLLER CATCH (1) IVES #336-B26 DOOR ROLLER CATCH

DATE: 08/20/2018

AREA: 1807 SQ.FT

HINGES: (3 PAIR) SOSS INVISIBLE HINGE #218 FINISH: WHITE E-COAT

SILENCERS: (3) IVES SR66; FINISH: WHITE

10' - 6" V.I.F.

PUSH PLATE: (1) IVES 8200 PUSH PLATE 3 1/3"W x 15"H FINISH: US32D STAINLESS STEEL

PROJECT NO.: 218231

3' - 3"

HINGES: (3 PAIR) EMTEK 95014 4" x 4" SQUARE CORNER SPRING HINGES; FINISH: US26 POLISHED CHROME

DOOR

CONCEALED EDGE PULL: (1) RAJACK HARDWARE KNIFE EDGE PULL FE158 CUSTOM FINISH: POWDER COAT TO MATCH DOOR FINISH - PT-01A

5' - 0"

PULL PLATE: (1) IVES PULL PLATE 8302; 31/2"W x 15"H PULL PLATE 8300 WITH 8102 PULL 6" CENTERS FINISH: US32D STAINLESS STEEL

7' - 0"

SET #6 - FITTING ROOM BLIND DOOR

NEW PRIVACY LEVERSET, PUSH BUTTON AT RESTROOM SIDE

5/8"

SET #5 - BACK OF HOUSE BLIND DOOR

7' - 0 3/4"

NOTE: KICK PLATE TO BE INSTALLED ON PUSH SIDE ONLY; INSTALL WALL STOP ON BOH SIDE. KEYED SIDE OF DEADBOLT TO BE INSTALLED ON CORRIDOR SIDE, THUMB-TURN AT BOH SIDE.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

RESTROOM (PUSH) DOOR TYPE "B" G.C. TO PROVIDE NEW BEST LOCKS AND 6 SETS OF KEYS

DOOR AND HARDWARE SCHEDULE

DOOR TYPE "A"

NOTE: INSTALL PULL AT FITTING ROOM SIDE OF DOOR SO THAT PULL OPENS OUT TO FITTING ROOM INSTALL PUSH PLATE AND KICK PLATE AT PUSH SIDE OF DOOR ONLY

1

DOOR TYPES SCALE: 1/2" = 1'-0"

A-601.00 SHEET 26 OF 27


15

DOOR TYPE 'F' SECTION / THRESHOLD 'H' SCALE: 3" = 1'-0"

12

T.O. DOOR FRAME

1/8"

2"

CUT BOARD

-0' - 3 1/4" A.F.F. EXISTING SLAB WOOD SLEEPERS SPACED @ 24" O.C. CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.

EXISTING SLAB TO REMAIN

9

THRESHOLD 'C'

2"

VESTIBULE (PULL)

3/8"

NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02

5/8"

NEW 5/8"THK WOOD FLOOR WF-01 3/4"THK PLYWOOD SUBFLOOR 0' - 0" A.F.F.

CHANGE FLOOR PATTERN

START OF CONCRETE TOPPING

(ALIGNS W/ TRANS EDGE)

(ALIGNS W/ TRANS EDGE)

5/8" THK WOOD PLANK CUT TO SIZE AT THRESHOLD TO ALIGN WITH BOTH SIDES OF TRANSITION OPENING

-0' - 3 1/4" A.F.F. STOREFRONT WINDOW DISPLAY (PUSH)

EXISTING SLAB WOOD SLEEPERS SPACED @ 24" O.C.;TYP. CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.

EQ 1 1/8"

4 7/8"

ALIGN

1 3/4"

2' - 0" DOOR 1/16"

EDGE OF TRANSITION VARIES

NEW 5/8"THK WOOD FLOOR WF-01

FITTING ROOM (PULL)

3/4"THK PLYWOOD SUBFLOOR

3"

2 1/8"

CUT BOARDS

EDGE PULL; REF. DOOR HARDWARE SCHEDULE

SCALE: 3" = 1'-0"

EXISTING SLAB

WOOD SLEEPERS SPACED @ 24" O.C. TYP. CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.

EXISTING SLAB TO REMAIN

NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02

PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR

13 A-602.00

PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN

BACK OF HOUSE (PULL)

2'-4 1/4" ROUGH OPENING 1/2"

WALL RUBBER BUMPER

1/2"

1" 1/2" 1/8"

WALL BASE AS SCHEDULED BELOW; EXTEND IN FRONT OF DOOR FRAME B-01

1/8"

2' - 0 1/2" (@ B.O.H. SIDE)

SHIM AS REQ'D

1" 5/8" TYPE 'X' GYP. BOARD

PULL PLATE, REF. DOOR HARDWARE SCHEDULE BLOCKING AS REQ'D

HINGE; REF. DOOR HARDWARE SCHEDULE

ALIGN

WOOD FLOOR -0' - 0 3/8" A.F.F. RAISED SLAB -0' - 3 1/4" A.F.F.

WALL BASE AS SCHEDULED BELOW; EXTEND IN FRONT OF DOOR FRAME AND PROVIDE BASE AT FACE OF DOOR

DOOR TYPE "F" PLAN DETAIL - FITTING ROOM BLIND DOOR

0' - 0" A.F.F.

2 1/8"

3/16"

G.C. TO CHAMFER WALL BASE BELOW @ 45 ANGLE AT HINGE SIDE OF DOOR AND ADJ WALL; PAINT ALL VISIBLE SURFACES TO MATCH ADJ BASE

NEW 1/8"THK SCHULTER SCHIENE M-100 BRASS TRANSITION STRIP NEW 3/8"THK POLISHED CONCRETE TOPPING, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-01

1 3/4" ALIGN

DOUBLE 20 GA. METAL STUDS @ JAMB

ALIGN 1 1/2"

1/8"

2' - 0" DOOR (@ STOREFRONT SIDE)

G.C. TO CHAMFER WALL BASE BELOW @ 45 ANGLE AT HINGE SIDE OF DOOR AND ADJ WALL; PAINT ALL VISIBLE SURFACES TO MATCH ADJ BASE

1/8"

5/8" TYPE 'X' GYP. BOARD. WALL BASE AS SCHEDULED BELOW; EXTEND IN FRONT OF DOOR FRAME AND PROVIDE BASE AT FACE OF DOOR

1 1/2"

STOREFRONT DISPLAY WINDOW (PUSH)

NOTE: G.C. TO HANG SHORTER DOOR AT STOREFRONT SIDE; REF. DOOR ELEVATIONS

EQ

EXISTING SLAB BELOW TO REMAIN

REF. A-104 FOR TRANSITION FINISHES

TRANSITION

PAINTED WOOD WALL BASE B-01 PT-02

WOOD FLOOR -0' - 0 3/8" A.F.F. RAISED FLOOR

BLOCKING AS REQ'D

EXTEND DISPLAY PLATFORM INTO DOOR OPENING AND ALIGN WITH FACE OF FRAME

SCRIBE PLANK TO CONCRETE AT TRANSITION EDGE HOLLOW METAL DOOR PAINTED PT-01B

FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM

5/8" TYPE 'X' GYP. BOARD.

6

SCALE: 3" = 1'-0"

5/8" TYPE 'X' GYP. BOARD

DOUBLE 20 GA. METAL STUDS @ JAMB

CONCEALED HINGES; REF. DOOR SCHEDULE

VARIES REF. PLAN

MEP ENGINEER:

EQ

WOOD FLOOR

1/8"

KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE

SCHULTER RENO-MTK 125 ADA COMPLIANT THRESHOLD

7' - 0" DOOR

1"

G.C. TO SHIM AS REQ'D

CLOSET (PUSH)

PAINT GRADE SOLID CORE WOOD CORE; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN

B.O.H. (PULL)

3 5/8" DOUBLE METAL STUD LINTEL

2 7/8"

1"

EQ

WALL RUBBER BUMPER

ALIGN

1"

1/2"

1"

1 1/2"

9' - 6 1/2" A.F.F.

WOOD FLOOR -0' - 0 3/8" A.F.F.

HOLLOW METAL DOOR FRAME PAINTED PT-01B

7' - 0" DOOR

SHIM AS REQ'D

0' - 0" A.F.F.

SCALE: 3" = 1'-0"

2"

3 5/8" METAL TRACKS

0' - 0" A.F.F.

DOOR TYPE 'D' SECTION / THRESHOLD 'F'

1/2" 1 3/4"

SHIM AS REQ'D

WALL BASE AS SCHEDULED BELOW; B-01

NEW 5/8"THK WOOD FLOOR WF-01 3/4"THK PLYWOOD SUBFLOOR

EXISTING SLAB

5/8"

PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR

SINGLE 5/8" THK WOOD PLANK CUT TO SIZE AT THRESHOLD TO ALIGN WITH BOTH SIDES OF TRANSITION OPENING

WOOD SLEEPERS SPACED @ 24" O.C.; TYP.

3 5/8" METAL TRACKS

3 5/8" DOUBLE METAL STUD LINTEL

VARIES

-0' - 3 1/4" A.F.F.

3 5/8" METAL FRAMING

3 5/8" METAL FRAMING

PAINTED WOOD WALL BASE B-01 PT-02

RAISED FLOOR

EXISTING SLAB BELOW TO REMAIN

1' 11 1/4" V.I.F.

EDGE OF TRANSITION

3/4"THK PLYWOOD SUBFLOOR

CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.

1/2" x 1 1/8" PAINTED WOOD DOOR STOP; FINISH TO MATCH DOOR FRAME

PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR

42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012

EXISTING SLAB

1/2"

1/2" 1 3/4" 1/2"

4"

-0' - 3 1/4" A.F.F.

2'-3 3/4" ROUGH OPENING

7/8"

CUT BOARD

STORAGE CLOSET (PUSH)

1" 3/4"

4 7/8"

NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02

2 7/8"

WOOD FLOOR

TRANSITION

NEW 5/8"THK WOOD FLOOR WF-01

0' - 0" A.F.F.

REF. A-104 FOR TRANSITION FINISHES

PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1"

APPLY WALL BASE AS SCHEDULED TO FITTING ROOM SIDE OF DOOR

(ALIGNS W/ TRANS EDGE)

KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE

VESTIBULE (PUSH)

SCHULTER RENO-MTK 125 ADA COMPLIANT THRESHOLD

(ALIGNS W/ TRANS EDGE)

ALIGN

FITTING ROOM (PULL)

BOH (PULL)

CHANGE FLOOR PATTERN

ALIGN

PAINT GRADE SOLID CORE WOOD CORE; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN

HOLLOW METAL DOOR PAINTED PT-01B

CHANGE FLOOR PATTERN

ALIGN

ALIGN 5/8"

KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE

ALIGN

STORAGE CLOSET (PULL)

G.C. TO SHIM AS REQ'D

ALIGN

EQ

7' - 0" DOOR

1 1/8"

15 A-602.00

5/8"

1 3/4"

1/2"

EQ

3 5/8" DOUBLE METAL STUD LINTEL

T.O. DOOR FRAME

1/8"

1 3/4"

G.C. TO SHIM AS REQ'D

HOLLOW METAL DOOR FRAME PAINTED PT-01B

3 5/8" METAL TRACKS

1/8"

3 5/8" DOUBLE METAL STUD LINTEL

3 5/8" METAL FRAMING

7' - 0" DOOR

3 5/8" METAL TRACKS

ARCHITECT OF RECORD:

2"

PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR 7' - 2 1/2" A.F.F.

3/8" 5/8"

3 5/8" METAL FRAMING

11

3 5/8" DOUBLE METAL STUD LINTEL

KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE

TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT DOOR FRAME

WHITE MARBLE SADDLE, CENTERED ON DOOR FRAME MS-01 RESTROOM (PUSH)

-0' - 0 3/8" A.F.F. RAISED SLAB NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02

-0' - 3 1/4" A.F.F. EXISTING SLAB

EXISTING SLAB TO REMAIN

13

DOOR TYPE 'E' SECTION / THRESHOLD 'G' SCALE: 3" = 1'-0"

HOLLOW METAL DOOR PAINTED PT-01B

CONTINUOUS VAPOR BARRIER NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB SLOPE TO DRAIN AT RESTROOM C-02 EXISTING SLAB BELOW TO REMAIN

10

VESTIBULE (PULL)

NEW 5/8"THK WOOD FLOOR WF-01 5/8"

NEW TILE FLOOR T-01 GROUT "MAPEI" COLOR: TBD (COORD. THICKNESS REQ'D W/ TILE MANUFACTURER RECOMMENDATIONS

EXISTING METAL STOREFRONT DOOR FRAME TO REMAIN

EXISTING STOREFRONT DOOR TO REMAIN

FR HOLLOW METAL DOOR FRAME

1:48 MAX SLOPE

0' - 0" A.F.F. WOOD FLOOR -0' - 0 3/8" A.F.F.

0' - 0" A.F.F. WOOD FLOOR & TILE FLOOR

RAISED SLAB -0' - 3 1/4" A.F.F. EXISTING SLAB

-0' - 3 1/4" A.F.F. EXISTING SLAB WOOD SLEEPERS SPACED @ 24" O.C.; TYP. EXISTING SLAB TO REMAIN

7

THRESHOLD 'A' SCALE: 3" = 1'-0"

2"

5/8"

5/8"

2"

5/8" TYPE 'X' GYP. BOARD

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218231 DATE: 08/20/2018

NEW 3/8"THK POLISHED CONCRETE TOPPING, G.C. TO FLOAT TOPPING AROUND DOOR TO ENSURE SURFACE ALIGNS WITH ENTRY THRESHOLD C-01

EXISTING SLOPED EXTERIOR SIDEWALK TO REMAIN

CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.

WALL BASE AS SCHEDULED BELOW

NEW 3/8"THK REMOVABLE WALK-OFF MAT CPT-02

EXISTING ADA COMPLIANT THRESHOLD TO REMAIN

3/4"THK PLYWOOD SUBFLOOR

DOOR TYPE 'B' SECTION / THRESHOLD 'D' SCALE: 3" = 1'-0"

SCALE: 3" = 1'-0"

(PUSH)

LEASE LINE

FLOAT TILE FLOOR UP TO MEET THRESHOLD

BOH WALL BASE AS SCHEDULED B-02

STAMP HERE:

HOLLOW METAL DOOR FRAME PAINTED PT-01B

3 5/8" METAL TRACKS

G.C. TO SHIM AS REQ'D

5

SCALE: 3" = 1'-0"

DOOR TYPE "E" PLAN DETAIL - BOH BLIND DOOR

2"

DISPLAY PLATFORM & B.O. EX'G MULLION

8

THRESHOLD 'B'

1/8"

2' - 5" A.F.F.

3 5/8" METAL FRAMING

7' - 0" DOOR

DISPLAY PLATFORM BY G.C.; G.C. TO EXTEND PLATFORM INTO DOOR OPENING

2"

5/8"

1 1/2"

1"

SCALE: 3" = 1'-0"

5/8"

KICK PLATE, AT BOH SIDE ONLY REF. DOOR HARDWARE SCHEDULE

DOOR TYPE 'C' SECTION / THRESHOLD 'E'

SHIM AS REQ'D

DRAWN BY: GR, RE, NK

DOUBLE 20 GA. METAL STUDS @ JAMB

CHECKED BY: JSP

BLOCKING AS REQ'D

HOLLOW METAL DOOR; REF. DOOR SCHEDULE

2"

3'-0" DOOR 1/8"

NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02

4

DOOR TYPE 'B'/'C'/'D' PLAN DETAIL SCALE: 3" = 1'-0"

#

ISSUE

DATE

1

ISSUE FOR PERMIT

09/07/2018

5/8" TYPE 'X' GYP. BOARD (TO BE WATER-RESISTANT AT WET WALLS)

WALL BASE AS SCHEDULED BELOW HINGE; REF. DOOR HARDWARE SCHEDULE

AREA: 1807 SQ.FT

(PULL)

2" 1/8"

PEMKO PK33W FIRE GASKETTING, TYP. LEVERSET, REF. DOOR HARDWARE SCHEDULE

DOOR AND THRESHOLD DETAILS

A-602.00 SHEET 27 OF 27


CONTACT LIST

DRAWING LIST

ABBREVIATIONS

ARCHITECT OF RECORD:

ISSUE

DAN KLACIK EMAIL: DKLACIK@BONOBOS.COM M: 908-801-0655 SAM HELLWEGE EMAIL: SHELLWEGE@BONOBOS.COM M: 646-460-3602

OWNER'S REPRESENTATIVE

O'NEIL LANGAN 15 WEST 37TH STREET 15TH FLOOR NEW YORK, NY 10018 JENNIFER SCHIAVONE-PALMA EMAIL: JENNIFER@OLARCH.COM P: 212-279-2670 x 240 STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 x 231

STANDARD FIXTURE PACKAGE 2018 A.01 NON-ILLUMINATED MIRROR - TYP.

F.02 - WALL MOUNTED DISPLAY BUNK

A.02 NON-ILLUMINATED MIRROR - LARGE

SHEET T-000 A-401 A-402 A-403 A-404 A-405 A-406 A-407 A-408 A-409 A-410 A-411 A-412 A-413 A-414 A-415 A-416 A-417 A-418 A-419 A-420

F.06 SALES JUNGLE GYM

A.03 FITTING ROOM MIRROR

F.03 - FREE STANDING RACK 1

F.07 MONDRIAN SCREEN

A.04 3-WAY MIRROR

F.04A - FREE STANDING RACK 2A F.04B - FREE STANDING RACK 2B (W/ SHELF)

F.08 GLASS AND BRASS STAND

SHEET TITLE COVER SHEET NON-ILLUMINATED MIRROR (A.01 & A.02) FITTING ROOM MIRROR (A.03) 3-WAY MIRROR (A.04) WALL MOUNTED FOCAL (F.01) WALL MOUNTED FOCAL (F.01) WALL-MOUNTED BUNK (F.02A, F.02B, F.02C) WALL-MOUNTED BUNK (F.02A, F.02B, F.02C) WALL-MOUNTED BUNK (F.02A, F.02B, F.02C) FREE-STANDING RACK 1 (F.03) FREE-STANDING RACK 2A (F.04A) FREE-STANDING RACK 2B (F.04B) STANDING RACK (F.05) JUNGLE GYM (F.06) OPTION A JUNGLE GYM (F.06) OPTION B JUNGLE GYM (F.06) OPTION C JUNGLE GYM (F.06) OPTION D MONDRIAN SCREEN (F.07) GLASS AND BRASS STAND (F.08) ADA FITTING ROOM BENCH (F.09) ADA FITTING ROOM BENCH (F.09)

2018 STANDARD FIXTURE PACKAGE

ROB QUELLMALZ EMAIL: RQUELLMALZ@BONOBOS.COM M: 646-710-3821

ISSUED FOR BID

JOSH BAILEY EMAIL: JBAILEY@BONOBOS.COM M: 512-925-3470

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

10/24/2018

LIZ WASSERMAN EMAIL: L.WASSERMAN@MODCLOTH.COM

ADJ. ADJACENT A.F.F ABOVE FINISHED FLOOR A.C.T. ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES BLK. BLOCKING CL CENTERLINE CLR. CLEAR CLG. CEILING CNTR. COUNTER CNT. CENTER CONC. CONCRETE COL COLUMN C.O.W CENTER OF WALL CPT. CARPET CONT. CONTINUOUS CONSTR. CONSTRUCTION C.G. CORNER GUARD CMU CONCRETE MASONRY UNIT DEMO DEMOLITION DWG. DRAWING DIA. DIAMETER DN. DOWN DR. DOOR ELEC. ELECTRICAL E.P. ELECTRICAL PANEL EMER. EMERGENCY EQ. EQUAL (E) EXISTING EA. EACH EXT. EXTERIOR FBO. FURNISHED BY OWNER F.C. FIXTURE CONTRACTOR F.F. FINISH FLOOR F.D. FLOOR DRAIN FR FRAME F.R.T FIRE RETARDANT TREATED F.S. FIRE EXTINGUISHER FURN. FURNISH F.O.W. FACE OF WALL GA. GAUGE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GWB. GYPSUM WALL BOARD HC HOLLOW CORE H.M. HOLLOW METAL HGT. HEIGHT HORIZ. HORIZONTAL IN INCH INST. INSTALL INSUL INSULATION KE KITCHEN EQUIPMENT L.O.D. LEASE OUTLINE DRAWING L.N. LANDLORD MAX MAXIMUM MAT'L. MATERIAL M.D.F. MAIN DISTRIBUTION FACILITY MECH. MECHANICAL MFR. MANUFACTURER MIR. MIRROR MIN. MINIMUM M.R. MOISTURE RESISTANT M.O. MASONRY OPENING N/A NOT APPLICABLE (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPG. OPENING OPP. OPPOSITE PT. PAINT PLWD. PLYWOOD P-LAM. PLASTIC LAMINATE PNL. PANEL QTY. QUANTITY RCP REFLECTED CEILING PLAN RB. RUBBER BASE REINF. REINFORCING REQ'D. REQUIRED REV. REVISED/REVISION R.R. RESTROOM SC SOLID CORE SCHED. SCHEDULE SF. SQUARE FOOT SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE SUSP. SUSPENDED TEMP. TEMPERED TBD TO BE DETERMINED TBV TO BE VERIFIED TYP. TYPICAL UON UNLESS OTHERWISE NOTED V.C.T. VINYL COMPOSITE TILE V.I.F VERIFIED IN FIELD VERT. VERTICAL WD WOOD

STAMP HERE:

F.01 - WALL MOUNTED FOCAL

F.05 - STANDING RACK

F.09 ADA FITTING ROOM BENCH

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: RE, NK CHECKED BY: JSP AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

FINISH SCHEDULE FINISH CODE FB-02 GL-01 GL-02 GL-03 GL-04 GL-05 GL-06 L-02 L-03 L-04 L-05 L-06 MT-01 MT-02 MT-04 PLM-01 PT-02

DESCRIPTION FABRIC - CUSHION MIRROR CLEAR GLASS PINK GLASS LIGHT GREEN GLASS WHITE FROSTED GLASS (50% TRANSPARENT) WHITE FROSTED GLASS (20% TRANSPARENT) WHITE LAQUER ORANGE LAQUER LIGHT PINK LAQUER LIGHT GREEN LAQUER GRAY LAQUER BRASS POWDER-COATED METAL POWDER-COATED METAL PLASTIC LAMINATE INTERIOR PAINT

MANUFACTURER TBD F.C. F.C. BENDHEIM BENDHEIM BENDHEIM BENDHEIM F.C. F.C. F.C. F.C. F.C. TBD F.C. F.C. FORMICA BENJAMIN MOORE

FINISHES

TBD CLEAR REFLECTIVE MIRROR, TEMPERED CLEAR GLASS, STARFIRE TEMPERED PINK GLASS, TEMPERED LIGHT GREEN GLASS, TEMPERED WHITE FROSTED GLASS (50% TRANSPARENT) WHITE FROSTED GLASS (20% TRANSPARENT) LAQUER TO MATCH BENJAMIN MOORE CHANTILLY LACE; 2121-70 - SATIN LAQUER TO MATCH PANTONE 1645C LAQUER TO MATCH PANTONE 488C LAQUER TO MATCH PANTONE 566C LAQUER TO MATCH BENJAMIN MOORE ANCHOR GRAY 2126-30 POLISHED BRASS WITH CLEAR COAT POWDER-COATED METAL TO MATCH BENJAMIN MOORE CHANTILLY LACE; 2121-70 - SATIN POWDER COATED METAL TO MATCH PANTONE 566C COLORCORE - WHITE CHANTILLY LACE; 2121-70 - SATIN

REMARKS/NOTES

BY OWNER (MODCLOTH) /BRAD JOBE F/I BY F.C. F/I BY F.C. F/I BY F.C. F/I BY F.C. F/I BY F.C. F/I BY F.C. F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F/I BY F.C. F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F/I BY F.C. F.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL

2018 FIXTURE PACKAGE COVER SHEET

T-000 SHEET 1 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

8 A-401

4' - 6" (A.02) 1 1/2" 1/2" 1/8"

3' - 0" (A.01) 7/8"

4' - 5" (A.02)

1/2"

1/2"

2' - 11" (A.01)

1' - 4 1/2"

3" RADIUS AT MIRROR CORNERS; TYP.

4' - 8" (A.02)

5"

3' - 2" (A.01)

5"

Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK

Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK

1/4" THK TEMPERED MIRROR GL-01

1' - 3"

1' - 2 1/4"

IN-WALL BLOCKING AS REQUIRED

1/4" THK TEMPERED MIRROR GL-01

5" 1' - 3"

MIRROR

6' - 6"

EDGE OF FRAME BEYOND

2018 STANDARD FIXTURE PACKAGE

1' - 4 1/2"

5"

5"

1' - 2 1/4"

7' - 3"

IN-WALL BLOCKING AS REQUIRED

T.O FIXTURE

5"

MIRROR

T.O. FIXTURE

7' - 3"

6' - 6"

BRASS FRAME; FINISH TO MATCH MT-01

2' - 2 1/8"

5/8" WOOD BACKING; PAINT GRADE MDF; FINISH TO MATCH PT-01

R

HOLD

9" 0' - 0" A.F.F. FINISHED FLOOR

8

3"

WALL BASE BELOW

HOLD

9"

BRASS FRAME; FINISH TO MATCH MT-01

NON-ILLUMINATED MIRROR - SECTION

0' - 0" A.F.F. FINISHED FLOOR

5

SCALE: 1 1/2" = 1'-0"

NON-ILLUMINATED MIRROR - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

PARTITION AS SCHEDULED

PARTITION AS SCHEDULED

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218299 (1) LAYER OF TYPE 'X' GYP. BOARD; FINISH TO MATCH PT-01

5/8" WOOD BACKING; PAINT GRADE MDF; FINISH TO MATCH

3/4" FRT PLYWOOD IN-WALL BLOCKING Z-CLIP; FINISH BLACK

Z-CLIP; FINISH BLACK

4' - 6" (A.02)

3/8" 1 1/8"

1 1/2"

PT-01

BLOCKING AS REQUIRED 5/8" PLYWOOD BACKING

A-401

7

SCALE: 6" = 1'-0"

CHECKED BY: JSP

A-401

#

ISSUE ISSUE FOR BID

DATE 10/24/2018

5/8" WOOD BACKING; PAINT GRADE MDF; FINISH TO MATCH PT-01 BRASS ANGLE FRAME; FINISH TO MATCH MT-01 1/4" THK TEMPERED MIRROR

NON-ILLUMINATED MIRROR (A.01 & A.02)

1/2" THK METAL FRAME; BRASS FINISH TO MATCH MT-01

NON-ILLUMINATED MIRROR - PLAN DETAIL

5 8

PAINT REVEAL BLACK 2 1/2"

3' - 0" (A.01)

7 A-401

1/4" THK TEMPERED GLASS 1/4"

DRAWN BY: NK AREA: N/A

7/8" 5/8"

1 1/2"

3/4" FRT PLYWOOD IN-WALL BLOCKING

DATE: 10/24/2018

4

NON-ILLUMINATED MIRROR - PLAN SCALE: 1 1/2" = 1'-0"

A-401 SHEET 2 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

8 A-402

2' - 6" 3 1/4" 2 3/8"

FRAME

1/2"

7/8"

1/2"

2' - 5"

1/2"

MIRROR

3" RADIUS AT MIRROR CORNERS; TYP.

11 1/2"

EDGE OF WALL

IN-WALL BLOCKING AS REQUIRED Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK

5"

5"

Z-CLIP; FINISH BLACK

1' - 7 1/2"

1' - 8 1/4"

1/4" THK TEMPERED MIRROR GL-01

BRASS FRAME; FINISH TO MATCH MT-01

5"

6' - 6"

IN-WALL BLOCKING AS REQUIRED

T.O. FIXTURE

5"

1' - 8 1/4"

11 1/2"

5" 1' - 6 1/4"

1/2"

3"

9"

HOLD

WALL BASE BELOW

HOLD

9"

EDGE OF FRAME BEYOND

R

BRASS FRAME TO MATCH MT-01

0' - 0" A.F.F. FINISHED FLOOR

8

2018 STANDARD FIXTURE PACKAGE

A.03

1' - 7 1/2"

7' - 3"

1/4" THK TEMPERED MIRROR GL-01

FRAME

IN-WALL BLOCKING AS REQUIRED

MIRROR 5"

T.O. FIXTURE

7' - 3"

6' - 6"

5/8" WOOD BACKING

FITTING ROOM MIRROR - SECTION

0' - 0" A.F.F. FINISHED FLOOR

5

SCALE: 1 1/2" = 1'-0"

FITTING ROOM MIRROR - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

PARTITION AS SCHEDULED

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218299 DATE: 10/24/2018

3/4" FRT PLYWOOD IN-WALL BLOCKING

2' - 6"

LED LIGHT BY F.C

2 1/2"

2 1/8"

5/8" 1/4" 1 1/8"

DRAWN BY: NK CHECKED BY: JSP

2 1/4" 1"

3 1/4"

ISSUE ISSUE FOR BID

DATE 10/24/2018

BRASS FRAME TO MATCH MT-01

1/4"

BLOCKING AS REQUIRED 5/8" THK PLYWOOD BACKING

1/4" THK TEMPERED MIRROR

5 8 A-402

A-402

FITTING ROOM MIRROR (A.03)

1/4" THK TEMPERED MIRROR 1/8"

PARTION AS SCHEDULED Z-CLIP; FINISH BLACK

#

7 A-402

1/4"

2 1/4"

3 1/4"

1"

5/8" THK WOOD BACKING

1/4"

2"

AREA: N/A

Z-CLIP; FINISH BLACK 5/8" THK PAINT GRADE MDF BACKING; FINISH TO MATCH PT-01

BRASS METAL FRAME; FINISH TO MATCH MT-01

2' - 1 1/2"

2 1/8" PAINT REVEAL BLACK 2 1/2"

7

ADA/FITTING ROOM MIRROR - PLAN DETAIL SCALE: 6" = 1'-0"

4

FITTING ROOM MIRROR - PLAN SCALE: 1 1/2" = 1'-0"

A-402 SHEET 3 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

8 A-403

3 1/4" 2 3/8"

3' - 8 1/2"

5/8" 1/4" 10"

1/4"

2' - 0"

1/4"

10"

BRASS FRAME; FINISH TO MATCH MT-01 3" RADIUS AT MIRROR CORNERS; TYP.

1' - 4"

1/4" THK TEMPERED MIRROR; FINISH TO MATCH GL-01 BRASS METAL FRAME; FINISH TO MATCH MT-01

1' - 9" 1/4" THK TEMPERED MIRROR GL-01

IN-WALL BLOCKING AS REQUIRED 5"

5/8" THK WOOD BACKING

1' - 3 3/8"

1' - 3 1/2"

5"

Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK

IN-WALL BLOCKING AS REQUIRED

5"

7' - 3"

MIRROR

6' - 6"

Z CLIPS; FINISH BLACK 5" 1' - 3 3/8"

1' - 3 1/2"

EDGE OF FRAME BEYOND

2018 STANDARD FIXTURE PACKAGE

MIRROR

T.O FIXTURE

7' - 3"

6' - 6"

A.04

3"

9"

HOLD

WALL BASE BELOW

HOLD

9"

R

1' - 11 1/8"

1' - 4"

5"

5"

OLIVE KNUCKLES HINGE; BRASS FINISH TO MATCH MT-01

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR B-01 PT-01B

8

3-WAY MIRROR - SECTION

5

SCALE: 1 1/2" = 1'-0"

3-WAY MIRROR - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

PARTITION AS SCHEDULED

PARTITION AS SCHEDULED LED LIGHT BY F.C.

3/4" FRT PLYWOOD IN-WALL BLOCKING

BRASS FRAME TO MATCH MT-01

3/4" FRT PLYWOOD IN-WALL BLOCKING

3' - 8 1/2" 10"

Z-CLIP; FINISH BLACK

1/4"

2' - 0"

1/4"

Z-CLIP; FINISH BLACK CLEAR RUBBER BUMPER

10"

PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: NK CHECKED BY: JSP AREA: N/A

5/8" THK WOOD BACKING OLIVE KNUCKLES; FINISH BRASS MT-01

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

# 5/8" THK PAINT GRADE MDF BACKING; FINISH TO MATCH PT-01 3 1/4"

BLOCKING AS REQUIRED

160°

CLEAR RUBBER BUMPER 1/4"

1/8"

1/4"

5/8"

10"

2 1/4"

5/8" THK WOOD BACKING

10"

1 1/8 "

2 1/4"

1/4" 2 1/8"

BRASS ANGLE FRAME; FINISH TO MATCH MT-01

DATE 10/24/2018

OLIVE KNUCKLES HINGE; BRASS FINISH TO MATCH MT-01

3 1/4"

1"

2"

ISSUE ISSUE FOR BID

BRASS ANGLE FRAME; FINISH TO MATCH MT-01

5 7 A-403

1/4" THK MIRROR ON 5/8" PLYWOOD BACKING

8 A-403

A-403

1/4" THK MIRROR ON 5/8" PLYWOOD BACKING

3-WAY MIRROR (A.04)

PAINT REVEAL BLACK

7

3-WAY MIRROR PLAN - PLAN DETAIL SCALE: 6" = 1'-0"

4

3-WAY MIRROR - PLAN SCALE: 1 1/2" = 1'-0"

A-403 SHEET 4 OF 21


ARCHITECT OF RECORD:

11 A-404

4"

4"

2' - 6"

1' - 0"

1"THK LAQUERED WOOD SHELF L-02 WITH CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD AND SECURED TO BACK WALL WITH METAL "L" ANGLE; BRASS FINISH TO MATCH MT-01

4"

4"

1"Ø METAL TUBE PRE-WELDED TO VERTICAL TUBE TYP; BRASS FINISH TO MATCH MT-01

4"

2' - 6"

4"

1' - 0"

4"

4"

2' - 6"

4"

4"

4"

4"

1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING 4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3/4"Ø x 6"L TUBE BRACKETS CONCEALED WITHIN WALL

6"

1"Ø METAL HANG ROD W/ THREADED CONNECTION ONE SIDE AND SLEEVE CONNECTION ONE SIDE TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01

4"

1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01

9"

1' - 4"

1' - 1"

4"

1/8"Ø x 1/2"H HANG ROD PINS FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01

6"

1' - 0"

3' - 2"

1' - 1"

2' - 5"

1' - 0"

6"

4"

4"

10 A-405

1' - 1"

4"

4"

1/8"Ø x 1/2"H HANG ROD PINS FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01

6"

9"

1' - 4"

9"

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING

1' - 1"

6"

1"Ø METAL FACE-OUT HANG BAR WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG BAR PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH

4"

3' - 11"

1' - 9"

11 A-405

9"

1' - 0"

6"

CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD; BRASS FINISH TO MATCH MT-01

4"

1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

1"THK LAQUERED WOOD SHELF FINISH TO MATCH L-02

CONTINUOUS METAL "L" ANGLE; BRASS FINISH TO MATCH MT-01

1' - 0"

9"

3 1/2"

2' - 5"

4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3/4"Ø x 6"L TUBE BRACKETS CONCEALED WITHIN WALL

1' - 0 1/2"

1' - 0"

1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01

4"

1' - 4"

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

4"

1"Ø METAL THREADED HORIZONTAL CONNECTOR PRE-WELDED TO VERTICAL TUBE, TYP.; BRASS FINISH TO MATCH MT-01

6' - 5"

4"

4"

7' - 2"

6"

1' - 1"

4"

1' - 4"

9"

1' - 1"

6"

9"

4"

4"

3' - 6"

3' - 6"

3' - 6"

4"

2018 STANDARD FIXTURE PACKAGE

4' - 0"

5' - 0"

STANDARD DRESS HANG

3' - 3"

4' - 10"

4' - 3"

TOPS AND SKIRTS HANG

3' - 3"

4' - 1"

5' - 9"

MAXI DRESS HANG

5' - 7"

4' - 9"

5' - 1"

11' - 2"

PARTITION AS SCHEDULED

BASE AS SCHEDULED BELOW

BASE AS SCHEDULED BELOW

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL

11

F.01 - SECTION SCALE: 1 1/2" = 1'-0"

NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL

8

F.01 - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

11

CONTINUOUS METAL "L" ANGLE, SECURED TO WALL WITH COUNTERSUNK SCREWS SPACED @ 12" O.C.; BRASS FINISH TO MATCH MT-01

1 A-405

A-404

11' - 2" 3' - 6"

3' - 6"

3' - 6"

4"

PARTITION AS SCHEDULED

1/8"

4"

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING

DATE: 10/24/2018 3' - 5"

1"

3' - 5"

SHELF

SHELF

L-02

L-02

1 1/4"

4" 2 A-405

4 A-405

1"

4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3/4"Ø x 6"L TUBE BRACKETS CONCEALED WITHIN WALL 1"Ø METAL TUBE PRE-WELDED TO VERTICAL TUBE TYP; BRASS FINISH TO MATCH MT-01

1/8"

L-02

11"

SHELF

1" SHELF

3' - 5"

1' - 0"

1' - 4"

PROJECT NO.: 218299

1/8"

1"

1"THK LAQUERED WOOD SHELF FINISH TO MATCH L-02 CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD; BRASS FINISH TO MATCH MT-01

1"Ø METAL FACE-OUT HANG BAR WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG BAR PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01 1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01

10

SCALE: N.T.S.

7

F.01 - PLAN SCALE: 1 1/2" = 1'-0"

DRAWN BY: RE CHECKED BY: JSP AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

3 A-405

1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01 NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL

F.01 - 3D VIEW

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

WALL MOUNTED FOCAL (F.01)

A-404 SHEET 5 OF 21


ARCHITECT OF RECORD:

1"Ø METAL THREADED HORIZONTAL CONNECTOR PRE-WELDED TO VERTICAL TUBE, TYP.; BRASS FINISH TO MATCH MT-01

1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01

1"Ø METAL HANG ROD W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR ONE SIDE ONLY; BRASS FINISH TO MATCH MT-01

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1"

1/2"

1/8"Ø x 1/2"H HANG ROD PIN FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01 1/2"

1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01

1/2"

1"

1/2"

2"

3/8"

3"

NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL

F.01 - EXPLODED 3D

F.01 - END CAP PLAN - SIDE TWO

3

SCALE: N.T.S.

SCALE: 6" = 1'-0"

1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01

CONTINUOUS METAL 'L' ANGLE SECURED TO WALL WITH COUNTERSUNK SCREWS SPACED @ 12" O.C. MAX; BRASS FINISH TO MATCH MT-01

1' - 0 5/8" 1/8"

1"Ø METAL HANG ROD W/ END SLEEVE CONNECTION TO HORIZONTAL CONNECTOR ONE SIDE ONLY; BRASS FINISH TO MATCH MT-01

3/8" 11"

1/8" 1 1/4"

1"

WOOD SHELF SECURED TO CUSTOM EDGE CAP W/ COUNTERSUNK SCREWS; BRASS FINISH TO MATCH MT-01

9 1/4"

1/8"Ø x 1/2"H HANG ROD PIN FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01

2"

4"

1/4"

3 3/4"

1/8"

1 1/4"

1"

1/8" 1/8" 1" 1/8" 1/8"

1/2"

1"Ø METAL FACE-OUT HANG ROD SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

1/8"

9/16"

1"

1 1/4"

1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01

10 1/4"

1/8"Ø x 1/2"H HANG ROD PIN FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01

2

F.01 - END CAP PLAN - SIDE ONE

1 1/4"

1/2"

NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL

1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01

4"

1 1/4"

3 1/4"

1/8"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

3/4"

PROJECT NO.: 218299 DATE: 10/24/2018

1"Ø METAL FACE-OUT HANG ROD SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

DRAWN BY: RE 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING PARTITION AS SCHEDULED

SCALE: 6" = 1'-0"

ISSUE ISSUE FOR BID

DATE 10/24/2018

COUNTERSUNK SET SCREW; BRASS FINISH TO MATCH

MT-01

1"

10

AREA: N/A

4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3"D x 3/4"Ø TUBE BRACKETS CONCEALED WITHIN WALL

1"Ø METAL TUBE INSTALLED OVER 6"L x 3/4"Ø BRACKET; F.C. TO CONFIRM GAUGE OF STEEL REQ'D FOR LOADING; BRASS FINISH TO MATCH MT-01

F.01 - HANG ROD SECTION

CHECKED BY: JSP #

1/4"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01

1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH

3/4"

STAMP HERE:

SCALE: 6" = 1'-0"

CUSTOM SLOTTED CONNECTOR PRE-WELDED TO FACE-OUT HANG RODS TO FIT OVER 1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01

1/8"

11"

1/8"

1/4"

1"Ø METAL TUBE BEYOND, CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01

1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01

1/4"

1/8"Ø x 1/2"L REMOVABLE HANG ROD PIN AT BACK OF HANG ROD FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01 1' - 4"

2"

1/2"

SET SCREW; BRASS FINISH TO MATCH MT-01

1"

1 1/4"

CUSTOM SLOTTED CONNECTOR PRE-WELDED TO FACE-OUT HANG RODS TO FIT OVER 1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01

1/2"

1/8"Ø x 1/2"L REMOVABLE HANG ROD PIN AT BACK OF HANG ROD FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01

1' - 2 1/2"

1/8"Ø x 1/2"H HANG ROD PINS FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01

3/8"

1"

SET SCREW; BRASS FINISH TO MATCH MT-01

SCALE: 6" = 1'-0"

UNDERSIDE OF FACE-OUT HANG ROD NOTCHED TO FIT AROUND PIN

3"

UNDERSIDE OF FACE-OUT HANG ROD NOTCHED TO FIT AROUND PIN

F.01 - SHELF SECTION

1"

1/2"

1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01

1"THK LAQUERED WOOD SHELF; FINISH TO MATCH L-02

WOOD SHELF SECURED TO METAL 'L' ANGLE W/ COUNTERSUNK SCREWS SPACED AT 12" O.C. MAX; BRASS FINISH TO MATCH MT-01

1/2"

1/2"

1"Ø METAL TUBE BEYOND, CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01

6"

1"

1"

9 1/2"

1"

PARTITION AS SCHEDULED

1/2" 1/2"

CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD; BRASS FINISH TO MATCH MT-01

1"

1"

SHELF

1/8"

1/8"

1"

11

1"Ø METAL THREADED HORIZONTAL CONNECTOR PREWELDED TO VERTICAL TUBE, TYP.; BRASS FINISH TO MATCH MT-01

2018 STANDARD FIXTURE PACKAGE

12

4

F.01 - FACE-OUT PLAN SCALE: 6" = 1'-0"

1

F.01 - WALL CONNECTION DETAIL SCALE: 6" = 1'-0"

WALL MOUNTED FOCAL (F.01)

A-405 SHEET 6 OF 21


ARCHITECT OF RECORD:

A-407

A-407

2' - 10 1/2"

1' - 3"

7' - 3"

7' - 5"

7' - 5"

6' - 9"

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

1 1/2"

3' - 3"

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3' - 2 3/4"

1 1/2"

1 1/2"

1' - 1 1/2"

DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH L-03

7" 4"

4"

4"

WALL BASE AS SCHEDULED BEYOND

1"

1"

1"

3"

7"

6"

1 1/2"

1' - 3"

1' - 3"

OPEN FRONT CUBBY W/ FINISHED BACK AND INSIDE TO MATCH L-04

1/8"

LACQUERED WOOD DRAWER SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET AND SCREWED TO METAL ANGLE AT BACK @ 12" O.C.; L-03 FINISH OUTSIDE SURFACES TO MATCH AND INSIDE SURFACES TO MATCH PLM-01

1 1/2"

ALL SURFACES OF CUBBY LACQUERED WOOD FINISH TO MATCH L-04

1' - 0" 1 1/2"

BOTTOM SHELF

1/8"

2018 STANDARD FIXTURE PACKAGE

2' - 11 3/4"

1 1/2"

1' - 8 1/8"

1' - 0"

1"

1/8"

2' - 0"

1 1/2" 1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

1' - 0"

1' - 3" PROVIDE (1) EXTRA SHELF W/ HANG WITH EACH F.02A DISPLAY BUNK W/ SHELVES IN ADDITION TO SHELF QUANTITY SHOWN

3' - 2 3/4"

1 1/2"

2' - 0"

1 1/2"

1' - 3"

1/8"

WALL BASE AS SCHEDULED 4 A-408

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

1 1/2"

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

1 1/2"

3' - 3"

1 1/2"

1' - 3"

2' - 3"

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

1 1/2"

3' - 3"

11 1/2"

1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

1' - 3" 1 1/2"

1 1/2"

1 1/2"

SHELF TYP.

1' - 4"

PROVIDE (1) EXTRA INTERMEDIATE SHELF WITH EACH F.02B DISPLAY BUNK IN ADDITION TO SHELF QUANTITY SHOWN

5' - 1 1/2"

TYP.

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

1' - 8 3/4"

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

2' - 0"

11 1/2"

6' - 3"

3/8"

9"

1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

PROVIDE (1) EXTRA SHELF W/ HANG WITH EACH F.02A DISPLAY BUNK IN ADDITION TO SHELF QUANTITY SHOWN

1 1/2"

1 1/2" 1' - 3"

5 A-408

11 1/2"

2' - 3"

1 1/2"

1' - 4"

1" 2"

1' - 3"

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

6"

1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

4' - 3"

1' - 5"

2' - 0"

1 1/2"

1' - 3"

11 1/2"

TOP SHELF

2' - 10 1/2"

1 1/2"

1 1/2"

1' - 8 3/4"

3/4"

6"

1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

1 1/2"

1"

3" 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.

1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

1 1/2" 3/8"

6"

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

7"

2' - 10 1/2"

1"

PARTITION AS SCHEDULED BY G.C.

A-406

6"

1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01

3/8"

5

1" 2"

1' - 8 3/4"

2

6"

6 A-408

11

1 1/2"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

11

DISPLAY BUNK WITH SHELVES F.02A

F.02A - SECTION W/ SHELVES SCALE: 1 1/2" = 1'-0"

1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

DISPLAY BUNK WITH SHELVES

DISPLAY BUNK WITH HANG ROD & CUBBY

F.02A

8

DISPLAY BUNK WITH HANG ROD & DRAWER

F.02B

F.02C

1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

F.02 - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01 1 1/2"

3' - 3"

1 1/2"

3' - 3" 11 1/2"

1' - 4"

1 1/2"

3' - 3"

11 1/2"

11 1/2"

1' - 4"

1 1/2" G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

11 1/2"

F.02B

11 1/4"

DISPLAY BUNK WITH HANG ROD & DRAWER

3/4"

PARTITION AS SCHEDULED BY G.C.

DATE: 10/24/2018

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

CHECKED BY: JSP

10

SCALE:

7

SCALE: 1 1/2" = 1'-0"

AREA: N/A ISSUE ISSUE FOR BID

DATE 10/24/2018

4"

#

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCHL-02

8 2 A-406

3/8"

CUSTOM CONNECTOR PRE-WELDED TO FACE-OUT HANG RODS TO FIT OVER 1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01 A-407

1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SUSPENDED ON 1/4"Ø HANG ROD SUPPORTS SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01

5

1"Ø METAL HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SUSPENDED ON 1/4"Ø HANG ROD SUPPORTS SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01

A-407

F.C. TO PROVIDE PRICING FOR EACH TYPE SEPARATELY (F.02A, F.02B, F.02C), PROVIDE (1) EXTRA SHELF WITH HANG FOR EACH F.02A MODULE AND (1) EXTRA INTERMEDIATE SHELF FOR EACH F.02B MODULE - IN ADDITION TO THE QUANTITY SHOWN ON THE DRAWINGS.

F.02 - PLAN

DRAWN BY: RE

8" 11 A-406

F.02 - 3D VIEW

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218299

F.02C

4 3/8"

1 1/2"

3/8"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

L-03 @ DRAWER BELOW

1' - 0"

3/4"

3/4" 11 3/8"

DISPLAY BUNK WITH HANG ROD & CUBBY

1 1/4"

F.02A

1/4"Ø HANG ROD SUPPORTS FOR FACEOUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

3 3/8"

SHELF TYP.

1' - 5"

1' - 8 3/4"

DISPLAY BUNK WITH SHELVES

1' - 9 1/8"

L-04 @ CUBBY BELOW

L-02

1' - 4"

3/8"

1 1/2"

3/4"

3/4"

WALL MOUNTED BUNK (F.02A, F.02B, & F.02C)

A-406 SHEET 7 OF 21


1' - 9 1/8"

1' - 8 3/4" SHELF W/ HANG

4"

1' - 5"

1 1/2"

PARTITION AS SCHEDULED BY G.C.

5' - 9"

1 1/2"

1 1/2"

PLM-01 INSIDE SURFACES 1' - 5 3/8"

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

1' - 8 1/8"

1' - 5 3/8"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

WALL BASE AS SCHEDULED

L-04

PARTITION AS SCHEDULED BY G.C. 3' - 6" 1 1/2"

PARTITION AS SCHEDULED BY G.C. 3' - 6" 1 1/2"

3' - 3"

1 1/2"

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

1/4" 5

1"

1 1/4"

3/4" 1 1/2"

1 1/2"

3/8" 1 1/2" 1/8"

DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH

A-407

DISPLAY BUNK CUBBY F.02B

2' - 11 3/4"

1/8"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3' - 2 3/4"

1 1/2"

1/8"

1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04

1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04

F.02C - PLAN AT DRAWER SCALE: 1 1/2" = 1'-0"

1' - 6 7/8"

1' - 4 3/4"

3/8"

1 1/4"

3' - 2 3/4"

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

L-04

SECURE DRAWER TO BACK ANGLE WITH SCREWS

F.02C

1/8"

4

DATE: 10/24/2018

1' - 5"

1/2" 1 1/8" 1/2" 3"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01 4"

3 3/4" SCALE: 6" = 1'-0"

3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.

1' - 9 1/8"

3/4" 1' - 8"

1' - 9 1/8"

1/2" 1"

DISPLAY BUNK DRAWER

3/4"

2 1/4" 7"

PARTITION AS SCHEDULED BY G.C.

9

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

PLM-01

1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

WALL BASE AS SCHEDULED

F.02C - SECTION DETAIL AT DRAWER

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

INSIDE SURFACES

SECURE DRAWER TO BACK ANGLE WITH COUNTERSUNK SCREWS

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

3/4"

1/4"

3' - 3"

F.02B

PROJECT NO.: 218299

HEAVY DUTY UNDERMOUNT DRAWER SLIDERS W/ NO SIDE BRACKETS

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

4"

3"

3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.

1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

DISPLAY BUNK WITH HANG ROD & CUBBY

F.02B - SECTION W/ CUBBY

2

SCALE: 1 1/2" = 1'-0"

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

1 1/2"

1 1/2" x 1 1/2" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

F.02C - SECTION W/ DRAWER

5

1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04

1" 1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

F.02C

1 1/2"

3/4"

1 1/2"

L-04

DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH

DISPLAY BUNK WITH HANG ROD & CUBBY

1' - 1 1/2"

INSIDE SURFACES TO MATCH PLM-01

1/2" 3/4"

11 1/2"

1/2" 1/2" 1/2"

1' - 5"

3/4"

DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH

1' - 3"

3/4"

3/8"

4"

3" 1/4"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

1"

LACQUERED WOOD DRAWER SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET AND SCREWED TO METAL ANGLE AT BACK @ 12" O.C.; FINISH OUTSIDE SURFACES TO MATCH L-03 AND INSIDE SURFACES TO MATCH PLM-01

3/4" 1 1/2"

10 A-407

7"

1 1/2"

3/8"

PROVIDE (1) EXTRA INTERMEDIATE SHELF WITH EACH F.02B DISPLAY BUNK IN ADDITION TO SHELF QUANTITY SHOWN

7"

1' - 5"

1/2" 3/4"

1 1/2"

1' - 3"

WALL BASE AS SCHEDULED

1' - 0"

SCALE: 6" = 1'-0"

1' - 9 1/8"

5' - 1 1/2"

LACQUERED WOOD DRAWER SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET AND SCREWED TO METAL ANGLE AT BACK @ 12" O.C.; FINISH OUTSIDE SURFACES TO MATCH L-03 AND INSIDE SURFACES TO MATCH PLM-01

3/8"

2' - 0"

F.02B - SECTION DETAIL AT CUBBY

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

1' - 9 1/8"

3/4" 1' - 5"

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

2' - 3"

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

1' - 9 1/8"

1 1/2"

1 1/2"

TYP.

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

9 A-407

1"

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

1' - 5"

4"

1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

1 1/2"

1 1/2"

4"

WALL BASE AS SCHEDULED

1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

HANG ROD

2' - 0"

3"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

4' - 3"

2' - 3" 1 1/2"

2 1/4" 3 3/4"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

3/8"

1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01

4"

1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

SECURE CUBBY TO BACK ANGLE WITH SCREWS; FINISH TO MATCH ADJ. SURFACE L-04

1' - 4"

1 1/2"THK LACQUERED WOOD SHELF W/ HANG ROD SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

5' - 4 1/2"

1' - 4"

3/4"

2' - 0"

1" 2"

2' - 0"

3/4" 3/4" 1 1/2"

7"

3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.

1 1/2"THK LACQUERED WOOD SHELF W/ HANG ROD SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

3/4"

HANG ROD

3/4"

SHELF W/ HANG TYP.

1 1/2"

L-04

1' - 3"

1' - 0"

BACK AND INSIDE SURFACE OF LACQUERED WOOD CUBBY TO MATCH

10

1' - 8 3/4"

2018 STANDARD FIXTURE PACKAGE

9" 3/8"

3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.

1 1/2"

3/8"

1' - 8 1/8" 9 A-408

3/4"

PARTITION AS SCHEDULED BY G.C.

1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01

3/8"

1' - 3"

7"

TOP SHELF

1' - 8 3/4"

1 1/2"

1' - 8 3/4"

10 A-408

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1"

1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01 4"

3/8"

3/8"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

3"

1' - 8 3/4"

1 1/2"

3/4"

6 A-408 SIM.

PARTITION AS SCHEDULED BY G.C.

1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04

1/4"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

1" 2"

3/8"

1' - 0"

1 1/2"

7"

1' - 5"

1 1/2"

1 1/2"

1 1/2"

3/4"

ARCHITECT OF RECORD:

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

2 A-407

1

SCALE: 1 1/2" = 1'-0"

CHECKED BY: Checker AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

SECURE CUBBY TO BACK ANGLE WITH SCREWS; FINISH TO MATCH ADJACENT SURFACE L-04

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

F.C. TO PROVIDE PRICING FOR EACH TYPE SEPARATELY (F.02A, F.02B, F.02C), PROVIDE (1) EXTRA SHELF WITH HANG FOR EACH F.02A MODULE AND (1) EXTRA INTERMEDIATE SHELF FOR EACH F.02B MODULE - IN ADDITION TO THE QUANTITY SHOWN ON THE DRAWINGS.

F.02B - PLAN AT CUBBY

DRAWN BY: Author

WALL MOUNTED BUNK (F.02A, F.02B, & F.02C)

A-407 SHEET 8 OF 21


ARCHITECT OF RECORD:

PARTITION AS SCHEDULED BY G.C. 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

TOP SHELF HELD FIXED IN PLACE BY SET SCREW AND ANGLE AT BACK BY F.C.; FINISH TO MATCH MT-01

1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01

3/8"

1"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02 1' - 8 3/4" TOP SHELF

1 1/2"

1 1/2"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3"

1' - 8 3/4" 1 1/4"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3"

1 1/2"

1 1/2"

1/4"

TOP SHELF

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

2 1/4"

3/4" 1 7/8"

2"

1 1/4"

2 1/4"

3/4"

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

4" 1 1/4"

10"

1"

2"

11 3/8"

1/8"

1"

1/8"

3 1/4"

1/8"

1 1/2"

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

2 1/2"

1' - 4 3/4"

1 1/2"

3/8"

1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01

1' - 9 1/8"

1 1/2" 3/8"

1' - 9 1/8"

6

F.02 - SECTION DETAIL AT TOP SHELF - TYP. SCALE: 6" = 1'-0"

1"Ø METAL FACE-OUT HANG ROD SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01

4 3/8"

1' - 5"

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

PARTITION AS SCHEDULED BY G.C. 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

3/8"

2018 STANDARD FIXTURE PACKAGE

3"

1/4"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3/8"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3"

TOP SHELF HELD FIXED IN PLACE BY SET SCREW AND ANGLE AT BACK BY F.C.; FINISH TO MATCH MT-01

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1"

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01

PARTITION AS SCHEDULED BY G.C.

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

1' - 8 3/4"

10

1 1/2"

SHELF TYP.

F.02 - SECTION DETAIL AT TOP SHELF W/ HANG SCALE: 6" = 1'-0"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

PARTITION AS SCHEDULED BY G.C.

3/4"

1 1/2"

1' - 5"

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

1 1/2" 3/8"

1' - 9 1/8"

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3/8"

5

F.02 - SECTION DETAIL AT INTERMEDIATE SHELF - TYP.

STAMP HERE:

SCALE: 6" = 1'-0"

1' - 8 3/4"

1' - 9 1/8"

INTERMEDIATE SHELF

3/8" 3/4"

1 1/2"

1' - 5"

1 1/2"

4" 1 1/4"

10"

1"

2"

BOTTOM SHELF HELD FIXED IN PLACE BY SET SCREW AND ANGLE AT BACK; FINISH TO MATCH MT-01 1"

1' - 4 3/4"

1"

1/8"

3 1/4"

1/8"

2 1/2"

1 1/2"

4 3/8" 1' - 9 1/8"

3/8"

1' - 8 1/8"

1/2"

BOTTOM SHELF

1"Ø METAL FACE-OUT HANG ROD SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01

3/4"

1 1/2"

1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01

3 3/4"

WALL BASE AS SCHEDULED PARTITION AS SCHEDULED BY G.C.

1"

3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.

9

F.02 - SECTION DETAIL AT INTERMEDIATE SHELF W/ HANG SCALE: 6" = 1'-0"

4

F.02 - SECTION DETAIL AT BOTTOM SHELF - TYP. SCALE: 6" = 1'-0"

DATE: 10/24/2018 DRAWN BY: Author CHECKED BY: Checker AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3"

1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01

PROJECT NO.: 218299

1 1/2"

1/8"

1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

2 1/4"

11 3/8"

1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01

7"

3/4"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01

3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.

4"

2"

1 7/8"

3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01

1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01

WALL MOUNTED BUNK (F.02A, F.02B, & F.02C)

A-408 SHEET 9 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

5 A-409

1/8"Ø x 7/8" STOP PIN BRASS FINISH TO MATCH MT-01

4' - 3" 1 1/2"

1/2" 1" 2 1/2"

2' - 11"

1"

1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01

10 1/2"

1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03 R

3"

1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01

10 "

1/8"Ø x 7/8" STOP PIN BRASS FINISH TO MATCH MT-01 1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-01 1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03

2018 STANDARD FIXTURE PACKAGE

5' - 9"

5' - 9"

5' - 2"

1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01

1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01

1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03 1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01

2

F.03 FREE STANDING RACK 1 - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

1' - 0 1/2"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

2 1/2"

1"

PROJECT NO.: 218299 DATE: 10/24/2018

1' - 0"

3' - 0"

2' - 2"

DRAWN BY: Author 1"

SCALE: 1 1/2" = 1'-0"

5"

80 °

F.03 FREE STANDING RACK 1 - SECTION

10 0°

CHECKED BY: Checker AREA: N/A #

3"

ISSUE ISSUE FOR BID

DATE 10/24/2018

1' - 0 1/2"

5

° 80

0° 10

4 1/2"

1"

1"

1/2"

1/8"Ø x 7/8" STOP PIN BRASS FINISH TO MATCH MT-01 1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01

1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01

1

F.03 FREE STANDING RACK 1 - PLAN SCALE: 1 1/2" = 1'-0"

1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01 1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03

FREE STANDING RACK 1 (F.03)

A-409 SHEET 10 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

5 A-410

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01 1" 2"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

4' - 0" 3' - 4"

1" 2" 1"

2018 STANDARD FIXTURE PACKAGE

5' - 9"

5' - 5"

5' - 9"

5' - 9"

1" 1" 1"

1" 2" 1"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

9

F.04A - FREE STANDING RACK 2A - LIGHT GREEN SCALE:

LAQUERED WOOD SHELF AT BASE L-05 OR L-06 LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06

R5 "

R

5"

1"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

1"

6 1/2"

1"

6 1/2"

1' - 2"

5

F.04A - FREE STANDING RACK 2A - SECTION

2

SCALE: 1 1/2" = 1'-0"

F.04A - FREE STANDING RACK 2A - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

4' - 0" 4' - 0"

6" 1"

5"

6"

3' - 0" 1"

2' - 10"

6" 1"

5"

3' - 0" 1"

2' - 10"

6"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

1"

1"

PROJECT NO.: 218299 1"

7

SCALE:

4

F.04A - FREE STANDING RACK 2A - PLAN AT BASE SCALE: 1 1/2" = 1'-0"

#

ISSUE ISSUE FOR BID

DATE 10/24/2018

5 1/2"

1"

AREA: N/A

1"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06

F.04A FREE STANDING RACK 2A - GRAY

CHECKED BY: Checker

1' - 2"

4"

1' - 2"

1"

5 1/2"

4"

5 1/2" 1"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

DRAWN BY: Author

5 1/2"

1"

DATE: 10/24/2018

LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06

1

F.04A - FREE STANDING RACK 2A - PLAN AT TOP SCALE: 1 1/2" = 1'-0"

FREE STANDING RACK 2A (F.04A)

A-410 SHEET 11 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671 5 A-411

4' - 0" 1" 2" 1"

3' - 4"

1" 2" 1"

1"

3' - 10"

1"

1" 1" 1"

1" 2"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

2018 STANDARD FIXTURE PACKAGE

5' - 9"

5' - 9"

4' - 5"

4' - 9"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

LAQUERED WOOD SHELF; FINISH TO MATCH L-05 OR L-06

1"

SCALE:

6 1/2"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

LAQUERED WOOD SHELF; FINISH TO MATCH L-05 OR L-06

LAQUERED WOOD SHELF AT BASE L-05 OR L-06

R

R5 "

10"

LAQUERED WOOD SHELF AT BASE L-05 OR L-06

5"

1"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

1"

11"

1"

1"

6 1/2"

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

1" 1"

F.04B FREE STANDING RACK 2B - OPT 2

10"

9

1' - 2"

5

F.04B - FREE STANDING RACK 2B - SECTION

2

SCALE: 1 1/2" = 1'-0"

F.04B FREE STANDING RACK 2B - ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

4' - 0"

6"

1"

5"

3' - 0"

1"

2' - 10"

6"

1"

5"

4' - 0"

1"

4"

3' - 4"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

4"

PROJECT NO.: 218299 DATE: 10/24/2018

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

7

F.04B FREE STANDING RACK 2B - OPT 1 SCALE:

4

LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06

F.04B FREE STANDING RACK 2B - PLAN AT BASE SCALE: 1 1/2" = 1'-0"

6 1/2"

CHECKED BY: JSP

1' - 2"

AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

6 1/2"

1"

1' - 2"

6 1/2"

1"

6 1/2"

DRAWN BY: EM

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

1

LAQUERED WOOD SHELVES BELOW; FINISH TO MATCH L-05 OR L-06

F.04B FREE STANDING RACK 2B - PLAN AT TOP SCALE: 1 1/2" = 1'-0"

FREE STANDING RACK 2B (F.04B)

A-411 SHEET 12 OF 21


ARCHITECT OF RECORD:

8 A-412 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1"

1/2"

1/2"

1/4" 1/8" Ø x 1/2" STOP PINS ON BOTH SIDES; BRASS FINISH TO MATCH MT-01

5' - 2" 1"

1"

EQ

1/8" Ø x 1/2" STOP PINS ON BOTH SIDES; BRASS FINISH TO MATCH MT-01

1 x 1 SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

R

99 /32 "

EQ

5' - 0"

1/2"

1"

1' - 6 5/8"

3/4"

11 1/8"

EDGE OF DISPLAY PLATFORM BY G.C.

HOLD

2 1/2"

2' - 6 3/4" A.F.F. WINDOW SILL

PIPING CLEARANCE WHERE APPLICABLE; REF. PLANS AND ELEVATIONS FOR EXACT LOCATIONS

2018 STANDARD FIXTURE PACKAGE

3/4"

7' - 5"

7' - 5"

5' - 0"

5' - 0"

1 x 1 SQ METAL TUBES; BRASS FINISH TO MATCH MT-01

PIPING CLEARANCE WHERE APPLICABLE; REF. PLANS AND ELEVATIONS FOR EXACT LOCATIONS

1' - 9 7/8" SIAMESE CLEARANCE

SIAMESE CLEARANCE

2' - 1 3/4"

2' - 5"

DISPLAY PLATFORM BY G.C.

DISPLAY PLATFORM

SIAMESE CLEARANCE

10 A-412

2' - 1 3/4"

DISPLAY PLATFORM

2' - 5"

2' - 5" A.F.F. T.O. PLATFORM

SALES SIDE

0' - 0" A.F.F. FINISHED FLOOR

0' - 0" A.F.F. FINISHED FLOOR

1' - 1" SIAMESE CLEARANCE

8

STANDING RACK SECTION

1

SCALE: 1 1/2" = 1'-0"

NOTE: MOUNTING PLATES MUST BE FABRICATED AND SENT TO JOBSITE EARLY

STANDING RACK ELEVATION

STAMP HERE:

SCALE: 1 1/2" = 1'-0"

8 A-412

7 7/8"

EDGE OF DISPLAY PLATFORM BY G.C

PROJECT NO.: 218299 DATE: 10/24/2018 CHECKED BY: JSP AREA: N/A

CONCEALED MOUNTING PLATE

ISSUE ISSUE FOR BID

DATE 10/24/2018

6 1/4"

MOUNTING PLATE

3 1/4"

1' - 0"

7 3/8"

1' - 0 1/2"

5' - 2"

#

1' - 0"

2' - 8" 1' - 0"

3/4" 1/8"

1' - 0"

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

DRAWN BY: EM 1/2"

DISPLAY PLATFORM BY G.C. PLM-01

1 x 1 SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

4' - 0"

7 3/8"

3 1/4"

1 1/2" 3/4"

1"

1' - 0"

1' - 0"

CONCEALED MOUNTING PLATE BLOCKING BY G.C.

3/4"

EXISTING STOREFRONT GLAZING GL-01

1"

1/2" 1/2"

1' - 7 1/2"

COUNTERSUNK SET SCREWS; FINISH TO MATCH MT-01

STOREFRONT

1"

ACCESS PANEL BY G.C. FINISH TO MATCH PLM-01

1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01

1' - 0"

STANDING RACK (F.05)

1

SALES

10

STANDING RACK SECTION DETAIL, TYP. SCALE: 6" = 1'-0"

4

STANDING RACK PLAN, TYP. SCALE: 1 1/2" = 1'-0"

A-412

A-412 SHEET 13 OF 21


ARCHITECT OF RECORD:

A-415

1' - 6"

1' - 6"

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

4' - 0 3/4"

ADJUSTABLE

FIXED

BAY

BAY

BAY

BAY BAY

A-415

1' - 6"

3' - 11 3/8"

1' - 11 7/8"

2' - 0"

1' - 9 7/8"

3' - 9"

4

7' - 5 1/4"

3' - 3"

BAY

FIXED ADJUSTABLE FIXED

1' - 6" 3"

1' - 11 7/8"

1' - 6"

1' - 6" 3"

4' - 0 1/8"

1' - 6"

1' - 6" 3"

1' - 0"

ADJUSTABLE

7' - 3 3/4"

3' - 7 1/4"

5' - 0 1/4"

2' - 6 3/4"

7' - 3 3/4"

7' - 3 3/4"

2' - 6 3/4" 6"

5' - 4"

1' - 6" 1' - 6" 3"

5' - 9 3/4"

2' - 6 3/4"

5 3/4"

2

1' - 10 5/8"

A-415

9' - 5 1/2"

1' - 5 1/4"

7' - 5 1/4"

1

1

F.06 - OPTION C ELEVATION EAST

3

SCALE: 1/2" = 1'-0"

F.06 - OPTION C ELEVATION SOUTH

2' - 0"

SCALE: 1/2" = 1'-0"

1' - 9 7/8"

3' - 9"

1' - 10 5/8"

9' - 5 1/2"

2

SCALE: 1/2" = 1'-0"

5' - 9 3/4"

2' - 6 3/4"

5

F.06 - JUNGLE GYM OPTION C SCALE: 1/2" = 1'-0"

3"

1' - 6"

1' - 6"

5' - 4"

1' - 5 1/4" 1' - 6 3/4" 3"

1' - 11 7/8"

3' - 11 3/8"

1' - 6"

FIXED BAY

ADJUSTABLE BAY

ADJUSTABLE BAY

ADJUSTABLE BAY

FIXED BAY

7' - 5 1/4"

9' - 5 1/2"

F.06 - OPTION C ELEVATION NORTH

5 3/4"

1' - 6"

1' - 5 1/4" 1' - 6 3/4"

1' - 11 1/4"

2018 STANDARD FIXTURE PACKAGE

1' - 9 7/8"

7' - 3 3/4"

7' - 3 3/4"

2' - 6"

3' - 9"

3"

3' - 4 3/4" 1' - 6"

1' - 11 3/8"

2' - 6 3/4"

6 1/2"

1' - 6 3/4"

A-415

4' - 0 3/4"

2' - 5 1/4" 3"

1' - 6"

1' - 6"

7' - 3 3/4"

1' - 7 1/2"

3

4

F.06 - OPTION C ELEVATION WEST

GLASS PANEL

STAMP HERE:

SCALE: 1/2" = 1'-0"

REMOVABLE DRAWER

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: JSP CHECKED BY: JSP AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

JUNGLE GYM (F.06) OPTION C

A-415 SHEET 16 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

WOOD BLOCKING AS REQ'D

8

CENTER SCREEN IN TRANSITION WIDTH

A-417 12 A-417

BRASS TRANSITION BY G.C., CENTER SCREEN WITHIN TRANSITION

1/8"

1/8" 1" GL-06

GL-04

REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS

GL-06

CENTER SCREEN IN TRANSITION WIDTH 1"

1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH 1"

2' - 9 1/2"

MT-01

EDGE OF TRANSITION BEYOND

EDGE OF TRANSITION BEYOND 1/4"

3/8"

1' - 10 1/2"

1"

MONDRIAN SCREEN - CEILING CONNECTION DETAIL

GL-06

3"

SILICONE 1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01 RUBBER SETTING AND CENTERING BLOCK

1"

8' - 11 1/2"

1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01

GL-04

COUNTERSUNK SCREWS TO SECURE FINISH PLATE; FINISH TO MATCH MT-01

WINDOW FIXTURE

EDGE OF TRANSITION BEYOND

4"H x 1/8" THK METAL FINISH PLATE; FINISH TO MATCH MT-01

1"

2018 STANDARD FIXTURE PACKAGE

1 1/4"

REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS

4' - 4 1/2"

3"

4"H x 1"D x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01

1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01

3/8" 1/8"

1/4"

4' - 4 1/2"

3/8" 1/8"

1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01

8' - 6 3/8"

1 1/4"

GL-04

1"

SCALE: 6" = 1'-0"

8' - 11 1/2"

12

REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS

1' - 6 1/2"

5' - 4 1/2"

3/8"

1" 1' - 10 1/2"

2' - 9"

1"

3 1/8"

1"

1"

1"

3 1/8"

9' - 0" A.F.F. LOUNGE TRANSITION

3' - 0 7/8"

SILICONE 1" x 1" x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01

1/8" 1"

1/2"

1' - 6"

2' - 1 3/8"

RUBBER SETTING AND CENTERING BLOCK

1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01

1/8" THK METAL ANGLE; FINISH TO MATCH MT-01

2' - 1 3/8"

1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01

COUNTERSUNK SCREWS SPACED @ 16" O.C. MAX.; FINISH TO MATCH

BRASS TRANSITION BY G.C., CENTER SCREEN WITHIN TRANSITION

9' - 0" A.F.F. LOUNGE TRANSITION

1 1/8"

BRASS TRANSITION BY G.C. 1/2"

1"

COUNTERSUNK SCREWS SPACED @ 16" O.C. MAX.

1" x 1" STEEL CHANNEL; BRASS FINISH TO MATCH MT-01

GL-06

4"H x 1/8" THK METAL FINISH PLATE; FINISH TO MATCH MT-01 SHIM AS REQ'D

FINISHED FLOORING AS SCHEDULED

FRT WOOD BLOCKING

0' - 0" A.F.F. FINISHED FLOOR

4"

4"

0' - 0" A.F.F. FINISHED FLOOR

4"H x 1"D x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01 4"

NEW 5/8"THK WOOD FLOOR, GLUED TO SUBFLOOR

1" 11 A-417

WOOD BLOCKING AS REQ'D

4' - 4 1/2"

1"

EQ

3' - 4 1/2"

MT-01

0' - 0" A.F.F. FINISHED FLOOR 1"

8' - 0"

EQ

COUNTERSUNK SCREW

11

MONDRIAN SCREEN - FLOOR CONNECTION DETAIL SCALE: 6" = 1'-0"

8

MONDRIAN SCREEN-SECTION

5

SCALE: 1" = 1'-0"

MONDARIAN SCREEN- ELEVATION

STAMP HERE:

SCALE: 1" = 1'-0"

REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS

1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01

4"H x 1"D x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01

REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS

SILICONE

REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS

1"

1' - 6"

1"

3/4" 1/4"

1/4"

4"H x 1/8" THK METAL FINISH PLATE AT BASE BELOW ; FINISH TO MATCH MT-01

4"H x 1/8" THK METAL FINISH PLATE BELOW; FINISH TO MATCH MT-01

1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01

1' - 2"

1"

1' - 6 1/2"

10

SCALE: 6" = 1'-0"

7

MONDRIAN SCREEN - END CAP DETAIL SCALE: 6" = 1'-0"

4

MONDRIAN SCREEN - PLAN SCALE: 1" = 1'-0"

1"

3' - 4 1/2"

1"

DRAWN BY: RE, NK CHECKED BY: JSP AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

7 A-417

10 A-417

5 A-417

MONDRIAN SCREEN - VERTICAL CHANNEL DETAIL

1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01

8' - 0"

1"

1"

PROJECT NO.: 218299 DATE: 10/24/2018

1 1/4"

3/8" 1/8"

1"

1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01

1/4"

1 1/4"

1"

1/4" 3/8" 1/8"

1 1/4"

3/8" 1/8"

3/8" 1/8"

RUBBER SETTING AND CENTERING BLOCK

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

8 A-417

MONDRIAN SCREEN (F.07)

A-417 SHEET 18 OF 21


ARCHITECT OF RECORD:

2018 STANDARD FIXTURE PACKAGE

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

STAMP HERE:

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: RE, GR CHECKED BY: JSP AREA: N/A #

ISSUE ISSUE FOR BID

DATE 10/24/2018

GLASS AND BRASS STAND (F.08)

A-418 SHEET 19 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

1

2

1

2

A-420

A-420

A-420

A-420

3' - 6" ADA BENCH CUSHION BY OWNER'S VENDOR 10 1/2"

HOLD

6"

1' - 1 1/2"

BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02

CUT-OUT FOR EASE OF INSTALL BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02

HOLD

BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02 HOLD

BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02

1' - 3"

BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02

HOLD 1' - 4 1/2"

1 1/2"

BOX IS SCREWED TO WALL; G.C TO PROVIDE INWALL BLOCKING; REF ELEVATIONS

MIN. TOE CLEARANCE 1 1/2"

BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02

1 1/2"

BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02

3' - 0"

1' - 3"

1'-9" CUTOUT

1 1/2"

10 1/2"

3' - 6"

HOLD 1' - 4 1/2"

HOLD

1' - 1 1/2"

ADA BENCH CUSHION BY OWNER'S VENDOR

BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH

1 1/2"

0' - 0" A.F.F. FINISHED FLOOR

2' - 10 1/2"

6"

2018 STANDARD FIXTURE PACKAGE

PT-02

LEG LEVELER AND T- NUT; TYP.

0' - 0" A.F.F. FINISHED FLOOR

3' - 0"

MIN.TOE CLEARANCE

4

ADA BENCH LONG SECTION

2

SCALE: 3" = 1'-0"

1

2

A-420

A-420

ADA BENCH SECTION THROUGH SETBACK SCALE: 3" = 1'-0"

1

2

A-420

A-420

3' - 6"

10 1/2"

1'-9" CUTOUT

BOX IS SCREWED TO WALL; G.C TO PROVIDE IN-WALL BLOCKING; REF ELEVATIONS

10 1/2"

HOLD 6"

3/4"

3 1/2"

3/4"

3' - 0"

MIN. TOE CLEARENCE

1 1/2"

ABOVE

BENCH SETBACK: (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02

STAMP HERE:

3' - 6"

HOLD

BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02

3/4"

3/4"

PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: RE HOLD

HOLD

1' - 8"

3/4"

HOLD

BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02

1' - 8"

3/4"

3/4"

MITER CORNER

CHECKED BY: JSP AREA: N/A

1 1/2"

#

MIN. TOE CLEARENCE

ADA BENCH PLAN SECTION SCALE: 3" = 1'-0"

3' - 0"

2 A-419

1

ADA BENCH PLAN SCALE: 3" = 1'-0"

MIN. TOE CLEARANCE

6"

1 1/2"

6"

A-419

2' - 9"

BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02

MIN. TOE CLEARANCE

2

1 1/2"

6"

BENCH TOP ABOVE; PAINT GRADE MDF; FINISH TO MATCH PT-02

3

3 1/2"

3/4"

1' - 2"

A-419

CUT-OUT ABOVE FOR EASE OF INSTALL LEG LEVELER AND T-NUT TYP.

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

4

HOLD

1' - 2"

11"

7" CUTOUT

A-419

ABOVE

4

ISSUE ISSUE FOR BID

DATE 10/24/2018

ADA FITTING ROOM BENCH (F.09)

A-419 SHEET 20 OF 21


ARCHITECT OF RECORD:

15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671

4

2

A-419

A-419

1' - 8" 1' - 2"

ADA BENCH CUSHION BY OWNER'S VENDOR

HOLD

6" MIN. TOE CLEARANCE

1 1/2"

1 1/2"

BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02

HOLD

HOLD 1' - 4 1/2"

BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02

1' - 3"

1' - 1 1/2"

BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02

BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02

2018 STANDARD FIXTURE PACKAGE

2

0' - 0" A.F.F. FINISHED FLOOR

ADA BENCH SHORT SECTION THROUGH SETBACK SCALE: 3" = 1'-0"

2 4

A-419

A-419

STAMP HERE:

1' - 8"

ADA BENCH CUSHION BY OWNER'S VENDOR

HOLD 3 1/2"

7" CUTOUT

9 1/2"

1 1/2"

BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02 1 1/2"

BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02

THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.

BOX IS SCREWED TO WALL; G.C TO PROVIDE IN-WALL BLOCKING; REF ELEVATIONS

PROJECT NO.: 218299

HOLD

1' - 3"

1' - 1 1/2"

CUT-OUT FOR EASE OF INSTALL

HOLD 1' - 4 1/2"

BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02

DATE: 10/24/2018 DRAWN BY: Author CHECKED BY: Checker AREA: N/A #

BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02

ISSUE ISSUE FOR BID

DATE 10/24/2018

0' - 0" A.F.F. FINISHED FLOOR

LEG LEVELER AND T-NUT TYP.

1 1/2"

11"

1' - 2"

1 1/2"

6"

ADA FITTING ROOM BENCH (F.09)

MIN. TOE CLEARANCE

3

ADA BENCH VIEW SCALE:

1

ADA BENCH SHORT SECTION SCALE: 3" = 1'-0"

A-420 SHEET 21 OF 21









Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.