ARCHITECT OF RECORD
DAVID A. UDKOW ARCHITECT 11881 NORTH 113 WAY SCOTTSDALE, AZ 85259 CONTACT: DAVID A UKDOW EMAIL: DAVIDAUDKOW@COX.NET P: 480-614-3385 F: 480-614-0209
MEP ENGINEER AEDIFICA 796 MERCUS COURT FENTON, MISSOURI 63026
OWNER'S REPRESENTATIVE O'NEIL LANGAN 15 WEST 37TH STREET 15TH FLOOR NEW YORK, NY 10018 CONTACT: STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 x 231
NORTH
TH
CONTACT: ALPESH CHAVADA, PE, SE MANAGER OF STRUCTURAL ENGINEERING EMAIL: ACHAVDA@OSBORN-ENG.COM P: 614-556-4272
AREA OF WORK TENANT SPACE 2120 #2 (1400 SQ FT)
2120 SOUTH BLVD, CHARLOTTE, NC
R
OSBORNE ENGINEERING 990 WEST 3RD AVE - SUITE 200 COLUMBUS, OHIO 43212
2
AREA PLAN
1
SCALE: N.T.S.
1. SCOPE OF WORK: THIS IS A PERMIT APPLICATION FOR INTERIOR IMPROVEMENTS FOR A NEW RETAIL STORE. THE PROJECT INCLUDES WORK ON THE GROUND FLOOR OF AN EXISTING BUILDING. WORK INCLUDES ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING WORK. NO CHANGE TO EXISTING USE, EGRESS, OR OCCUPANCY. FIRE ALARM AND SPRINKLER TO BE FILED UNDER DEFERRED SUBMITTAL. 2. GOVERNING CODES: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO THE REQUIREMENTS OF THE FOLLOWING (INCLUDING AMENDMENTS), AND ANY OTHER FEDERAL, STATE AND LOCAL CODES, LAWS AND ORDINANCES THAT APPLY: 2018 N.C. BUILDING CODE 2018 N.C. EXISTING BUILDING CODE 2018 N.C. ENERGY CONSERVATION CODE 2018 N.C. FIRE PREVENTION CODE 2018 N.C. MECHANICAL CODE 2018 N.C. PLUMBING CODE 2018 N.C. FUEL GAS CODE 2017 NATIONAL ELECTRIC CODE ANSI A117.1, 2009 3. CONSTRUCTION SERVICE CENTER: MECKLENBURG COUNTY CODE ENFORCEMENT 2145 SUTTLE AVE, CHARLOTTE, NC 28208
CONTACT: AMY DIEKEVERS EMAIL: AMYD@PRECISIONPERMITS.COM P: 616-493-9334
---
SCALE: N.T.S.
STRUCTURAL FRAME (COLUMNS, ETC): BEARING WALLS (EXTERIOR): NON BEARING WALLS (EXTERIOR): NON BEARING (INTERIOR): FLOOR CONSTRUCTION ( INCL. SUPPORTS):
5. OCCUPANT GROUP: GROUP "M" (MERCANTILE)
7. OCCUPANT LOAD: (PER 2018 NC. BUILDING CODE: CHAPTER 10, TABLE 1004.2.1) FLOOR AREA: SALES: 1138 SQ FT / 60 = STOCK: 204 SQ FT / 300 = RESTROOM: 58 SQ FT/300 = NUMBER OF OCCUPANTS: TOTAL:
10. FIRE RATED ASSEMBLIES: A. EXISTING DEMISING PARTITIONS: • BACK WALL: 2-HR FIRE RATED 8" CMU PARTITION (UL-U905) INSULATED WITH 1 1/4" POLYISOCYANURATE FOAM SHEATHING (R 7.6) WITH 2 1/2" Z FURRING AT 24" O.C. AND (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD AT INTERIOR SIDE. FIRE-RATED ACOUSTICAL CAULKING TO SEAL ALL GAPS AT TOP AND BOTTOM OF PARTITION. G.C. TO PATCH AND RE-SEAL AS REQUIRED TO RESTORE THE DEMISING PARTITIONS TO THEIR ORIGINAL FIRE PROTECTION RATING. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. • SIDE WALLS: 1-HR FIRE-RATED PARTITION (UL-U465) WITH 5/8" TYPE "X" GYPSUM BOARD BOTH SIDES OF 6" METAL STUDS. FRAMING AND GYP. BD TO EXTEND TO BOTTOM OF METAL DECK ABOVE. FIRE-RATED ACOUSTICAL CAULKING TO SEAL ALL GAPS AT TOP AND BOTTOM OF PARTITION. G.C. TO PATCH AND RE-SEAL AS REQUIRED TO RESTORE THE DEMISING PARTITIONS TO THEIR ORIGINAL FIRE PROTECTION RATING. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. B. ALL PENETRATIONS (INCLUDING FOR PIPES AND CONDUITS) THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH UL LISTED THROUGH PENETRATION FIRESTOP SYSTEMS AND FIRE-RATED SEALANT WITH RATINGS EQUAL TO THAT OF THE RATED ASSEMBLIES THROUGH WHICH THEY PASS. C. COLUMNS, GIRDERS, BEAMS, JOISTS,AND SLABS ALL ARE PART OF LANDLORD ASSEMBLY AND HAVE EXISTING FIRE PROTECTION WHICH SHOULD REMAIN. EXISTING DECK IS 3 HOUR-RATED. WHERE SUCH FIRE PROTECTION IS DAMAGED, IT SHALL BE RESTORED TO ITS ORIGINAL CONDITIONS AND FIRE PROTECTION RATING. TENANT CEILING (NON-COMBUSTIBLE) DOES NOT FORM A PART OF THE LANDLORD RATED ROOF ASSEMBLY. D. ALL CEILING AND WALL MATERIALS MUST BE CLASS 'A'; INTERIOR FINISHES TO BE CLASS C OR GREATER. DOES NOT APPLY TO TRIM DEFINED AS BASEBOARDS AND MOLDINGS, OR TO MATERIALS LESS THAN 1/28 INCH IN THICKNESS APPLIED DIRECTLY TO SURFACE OF WALLS OR CEILINGS.
16. HANDICAP ACCESSIBILITY: A. AN ACCESSIBLE ROUTE IS EXISTING FROM THE EXTERIOR TO THIS TENANTS SPACE. SEE ORIGINAL LANDLORD SITE AND BUILDING PLANS ON FILE. B. THIS TENANT SPACE IS FULLY ACCESSIBLE TO ALL AREAS OCCUPIED BY THE PUBLIC, ACCESSIBLE EMPLOYEE WORK AREAS HAVE BEEN PROVIDED. C. WHERE INDICATED PROVIDE INDUSTRY STANDARD ADA APPROVED SIGNAGE, PROPOERLY ADDRESSING RAISED AND BRAILLE CHARACTERS, PICTOGRAMS, FINISH AND CONTRAST, CHARACTER PROPORTION AND HEIGHT, AND MOUNTING HEIGHT. 17. SANITARY FACILITIES: (PER 2018 N.C PLUMBING CODE TABLE 403.1) (1) EXISTING UNISEX RESTROOM, FULLY ACCESSIBLE TO CUSTOMERS AND EMPLOYEES TO BE PROVIDED BY LANDLORD 18. DRINKING FOUNTAIN: (PER 2018 N.C PLUMBING CODE TABLE 403.1) (1) WATER DISPENSER THAT COMPLIES WITH THE REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR & FOR STANDING PERSONS TO BE PROVIDED IN LIEU OF A DRINKING FOUNTAIN.
●
●
01 - GENERAL G-001 ACCESSIBILITY COMPLIANCE G-002 EGRESS & ACCESSIBILITY PLAN G-003 RESPONSIBILITY SCHEDULE G-004 APPENDIX B FORM
● ● ● ●
● ● ● ●
03 - ARCHITECTURAL A-100 CONSTRUCTION PLAN A-101 FIXTURE PLAN A-102 REFLECTED CEILING PLAN A-103 POWER & SIGNAL PLAN A-104 FLOOR & WALL FINISH PLAN A-300 BUILDING SECTIONS A-301 INTERIOR ELEVATIONS - CASUAL SHOP & TAILORED SHOP A-302 INTERIOR ELEVATIONS - CASUAL SHOP & TAILORED SHOP A-303 INTERIOR ELEVATIONS - LOUNGE & FITTING ROOMS A-304 INTERIOR ELEVATIONS - ADA FITTING ROOM/ VESTIBULE & RESTROOM A-305 INTERIOR ELEVATIONS - BOH DETAILS A-306 ENLARGED RESTROOM PLANS & ELEVATIONS A-400 FREE-STANDING FITTING ROOM DETAILS A-500 CONSTRUCTION & CEILING DETAILS A-501 CONSTRUCTION & CEILING DETAILS A-502 CONSTRUCTION DETAILS AT STOREFRONT A-600 PARTITION, TRIM, & THRESHOLD DETAILS A-601 DOOR & HARDWARE SCHEDULE & DETAILS A-602 STOREFRONT SIGNAGE DETAILS
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
04 - STRUCTURAL S-101 STRUCTURAL PLAN
●
●
05 - MECHANICAL M-100 MECHANICAL SPECIFICATIONS M-200 MECHANICAL PLAN
● ●
● ●
06 - PLUMBING P-100 PLUMBING SPECIFICATIONS P-200 PLUMBING PLAN
● ●
● ●
07 - ELECTRICAL E-100 ELECTRICAL TITLE SHEET E-200 ELECTRICAL SPECIFICATIONS (1 OF 2) E-201 ELECTRICAL SPECIFICATIONS (2 OF 2) E-300 ELECTRICAL POWER & LOW VOLTAGE PLAN E-400 ELECTRICAL LIGHTING PLAN E-500 POWER ONE-LINE DIAGRAM & PANEL SCHEDULES E-600 LIGHTING ENERGY COMPLIANCE E-601 LIGHTING ENERGY COMPLIANCE
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
08 - FIRE PROTECTION FP-100 FIRE PROTECTION PLAN
●
●
CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550 STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
STAMP
19. SERVICE SINK: (PER 2018 N.C PLUMBING CODE TABLE 403.1) (1) SERVICE SINK TO BE PROVIDED
11. FIRE RESISTANCE RATING REQUIREMENT (PER 2018 NC. BUILDING CODE, TABLE 601) BUILDING ELEMENTS:
6. TENANT LEASE AREA: 1400 SQ.FT.
PRECISION PERMIT SERVICES 75 - 60TH SREET SW WYOMING, MI 49548
SITE PLAN
BUILDING CODE ANALYSIS & CODE NOTES
4. CONSTRUCTION TYPE: TYPE : IA FULLY SPRINKLERED NUMBER OF STORIES: 1 (TENANT WORK ON LEVEL ONE ONLY)
EXPEDITOR
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER
00 - COVER SHEET T-000 COVER SHEET
O
STRUCTURAL ENGINEER
OWNER'S REPRESENTATIVE
G-006 Unnamed
N
CONTACT: RANDY BUECHELE EMAIL: RBUECHELE@AEDIFICA.COM P: 636-649-1600 X224 F: 636-349-1730
2120 SOUTH BVLD, SUITE #2 CHARLOTTE, NC 28203
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
CONTACT: JIM SALOKA SENIOR CONSTRUCTION MANAGER EMAIL: JSALOKA@EDENS.COM P: 803-744-2475 M: 571-242-9998
RETAIL TENANT
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
RETAIL TENANT
EDENS 1221 MAIN STREET, SUITE 1000 COLUMBIA, SC 29201
ISSUE
ISSUE FOR CONSTRUCTION 03/04/2019
LANDLORD'S REPRESENTATIVE
ADJ. ADJACENT A.F.F ABOVE FINISHED FLOOR A.C.T. ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES BLK. BLOCKING CL CENTERLINE CLR. CLEAR CLG. CEILING CNTR. COUNTER CNT. CENTER CONC. CONCRETE COL COLUMN C.O.W CENTER OF WALL CPT. CARPET CONT. CONTINUOUS CONSTR. CONSTRUCTION C.G. CORNER GUARD CMU CONCRETE MASONRY UNIT DEMO DEMOLITION DWG. DRAWING DIA. DIAMETER DN. DOWN DR. DOOR ELEC. ELECTRICAL E.P. ELECTRICAL PANEL EMER. EMERGENCY EQ. EQUAL (E) EXISTING EA. EACH EXT. EXTERIOR FBO. FURNISHED BY OWNER F.C. FIXTURE CONTRACTOR F.F. FINISH FLOOR F.D. FLOOR DRAIN FR FRAME F.R.T FIRE RETARDANT TREATED F.S. FIRE EXTINGUISHER FURN. FURNISH F.O.W. FACE OF WALL GA. GAUGE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GWB. GYPSUM WALL BOARD HC HOLLOW CORE H.M. HOLLOW METAL HGT. HEIGHT HORIZ. HORIZONTAL IN INCH INST. INSTALL INSUL INSULATION KE KITCHEN EQUIPMENT L.O.D. LEASE OUTLINE DRAWING L.N. LANDLORD MAX MAXIMUM MAT'L. MATERIAL M.D.F. MAIN DISTRIBUTION FACILITY MECH. MECHANICAL MFR. MANUFACTURER MIR. MIRROR MIN. MINIMUM M.R. MOISTURE RESISTANT M.O. MASONRY OPENING N/A NOT APPLICABLE (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPG. OPENING OPP. OPPOSITE PT. PAINT PLWD. PLYWOOD P-LAM. PLASTIC LAMINATE PNL. PANEL QTY. QUANTITY RCP REFLECTED CEILING PLAN RB. RUBBER BASE REINF. REINFORCING REQ'D. REQUIRED REV. REVISED/REVISION R.R. RESTROOM SC SOLID CORE SCHED. SCHEDULE SF. SQUARE FOOT SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE SUSP. SUSPENDED TEMP. TEMPERED TBD TO BE DETERMINED TBV TO BE VERIFIED TYP. TYPICAL UON UNLESS OTHERWISE NOTED V.C.T. VINYL COMPOSITE TILE V.I.F VERIFIED IN FIELD VERT. VERTICAL WD WOOD
ARCHITECT
DRAWING LIST
ABBREVIATIONS
ISSUE FOR LANDLORD APPROVAL/BID 02/27/2019
TENANT
19 OCCUPANTS 1 OCCUPANT 1 OCCUPANT 21 OCCUPANTS
8. EXITS REQUIRED: OCCUPANT LOAD < 50 REQUIRES MINIMUM OF 1 EXIT (PER 2018 NC. BUILDING CODE: SECTION 1006.2.1) NUMBER OF EXITS REQUIRED BY OCCUPANT LOAD: 1 NUMBER OF EXITS PROVIDED: 2 MAXIMUM TRAVEL DISTANCE TO MALL: 75 FT (PER 2018 NC. BUILDING CODE: SECTION 1006.2) MAXIMUM TRAVEL DISTANCE TO MALL EXIT: 250 FT (PER 2018 NC. BUILDING CODE: SECTION 1017.2 ) ACTUAL TRAVEL DISTANCES (REF. G-003 EGRESS PLAN): ROUTE 1: 55'-3" ROUTE 2: 49'-10" ROUTE 3: 17'-9" EGRESS WIDTH PER OCCUPANT SERVED: (0.15) x 21 PERSONS = 3.15 IN 9. EXITS PROVIDED AND DATA: ONE (1) EXISTING EXIT TO MALL AT STOREFRONT @ 5'-4 1/2" (2 LEAVES X 2'-8 1/4") CLEAR WIDTH ONE (1) EXISTING EXIT AT BOH @ 2'-10 1/4" CLEAR WIDTH A. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. B. A CLEAR AISLE BETWEEN EXITS OF 36" SHALL BE MAINTAINED FREE OF FIXTURES, MERCHANDISE AND OTHER OBSTRUCTIONS. C. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED AND SHALL CONFORM TO 2018 NC. BUILDING CODE.
3 HR 3 HR 0 HR 0 HR 2 HR
BASED ON FIRE SEPARATION DISTANCE (PER 2018 NC. BUILDING CODE, TABLE 602) EXTERIOR WALLS: 10≤X< 30: 1 HR 12. LIFE SAFETY SYSTEMS: A. FIRE SPRINKLER SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. SPRINKLER CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ONSITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. B. FIRE ALARM SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. FIRE ALARM CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ON-SITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. C. EMERGENCY LIGHTING - NEW, PROVIDED BY TENANT
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
13. FLAME SPREAD RATINGS FOR INTERIOR FINISHES: FLAME SPREAD RATINGS FOR INTERIOR FINISHES SHALL COMPLY WITH 2015 IFC, TABLE 803.3 BUT IN NO CASE SHALL EXCEED CLASS C, MAX FLAME SPREAD INDEX OF 75; MAX SMOKE-DEVELOPED INDEX OF 450 14. FIRE EXTINGUISHERS: (PER 2015 IFC, TABLE 906.1, TABLE 906.3(1)) A. ONE FIRE EXTINGUISHER SHALL BE PROVIDED AT ONE PER 3,000 SF; COVERAGE NOT TO EXCEED 75 FEET IN ANY DIRECTION. TENANT SHALL HAVE AT LEAST ONE IN THE STOCK ROOM AREA. B. PROVISIONS AND INSTALLATION IN THE QUANTITY, TYPE AND LOCATIONS REQUIRED BY THE FIRE MARSHALL SHALL PREVAIL.
COVER SHEET
15. HAZARDOUS MATERIALS: TESTING, REMOVAL, AND/OR ENCAPSULATION ARE NOT PART OF THIS CONTRACT. IT IS NOT SUSPECTED ANY HAZARDOUS MATERIALS WILL BE FOUND. IF THE PRESENCE OF HAZARDOUS MATERIAL IS SUSPECTED OR DISCOVERED, NOTIFY THE BUILDING OWNER AND CLIENT IMMEDIATELY.
T-000
DATE 02/27/2019 03/04/2019
ARCHITECT
C
B
A
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
OWNER'S REPRESENTATIVE
FE
TRAVEL DISTANCE FROM POINT A TO EXIT 1: 55'-9"
MEP ENGINEER
TRAVEL DISTANCE FROM POINT B TO EXIT 1: 55'-3"
CASE ENGINEERING, INC.
TRAVEL DISTANCE FROM POINT C TO EXIT 2: 17'-9"
cCLEAR
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550
20' - 10"
3' 0" CL EA R
3' - 0"
LEASE LINE TO LEASE LINE
CLEAR CLEAR
5' - 4 1/2"
2' - 8 1/4" EXIT 1
2' - 8 1/4"
CLEAR
3' - 0"
EXIT 2
CLEAR
CLEAR
3' - 0"
CLEAR
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
3' - 0"
CLEAR
2' - 10 1/4"
3' - 0"
POINT B
STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
NORTH
EGRESS PLAN SCALE: 1/4" = 1'-0"
EGRESS PLAN SYMBOL / HATCH LEGEND SYMBOL / HATCH
DESCRIPTION
EXISTING PARTITION TO REMAIN
36" CLEAR
NEW PARTITION
4"
EGRESS PLAN GENERAL NOTES:
EGRESS PATH
OCCUPANT GROUP
1. IT IS THE RESPONSIBILITY OF THE G.C. TO FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS.
GROUP 'M' MECHANTILE
2. NOTHING SHALL BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THROUGH THE FLOOR OR ROOF DECK ABOVE.
AREA & EGRESS CALCULATIONS
3. IT IS THE RESPONSIBILITY OF THE G.C. TO FIELD VERIFY EXISTING ELECTRICAL SERVICE AND TO MAKE ANY AND ALL MODIFICATIONS REQUIRED TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED ELECTRICAL SERVICE. 4. ENSURE THAT LAYOUT AND ALL FIXTURES COMPLY WITH LATEST CODE AND ADA REQUIREMENTS.
2" MIN
5. FIRE EXTINGUISHER SHALL BE PLACED NO LESS THAN 18 INCHES ADJACENT TO THE DOOR FROM THE FORWARD APPROACH ON THE PULL SIDE AND NO LESS THAN 12 INCHES ADJACENT TO THE DOOR FROM THE PUSH SIDE.
SPACE TYPE/ NAME SALES AREA STOCK ROOM RESTROOM TOTAL
SF AREA 1138 SF (GROSS) 204 SF (GROSS) 58 SF (GROSS) 1400 SF (GROSS)
OCCUPANCY LOAD SF / 60 = 19 OCCUPANTS SF / 300 = 1 OCCUPANTS SF / 300 = 1 OCCUPANTS 21 OCCUPANTS
TOTAL % 81% 15% 4% 100 %
EXITS PROVIDED EXIT EXIT 1- STOREFRONT ENTRY EXIT 2- BACK OF HOUSE EXIT
WIDTH 2 LEAVES X (2'-8 1/4") CLEAR EACH 2'- 10 1/4" CLEAR (32" MIN. CLEAR)
STAMP
EXIT SIGN; REF. RCP FOR FULL SPEC AND LOCATION
FIRE EXTINGUISHER
MOUNTING BRACKET AS REQUIRED
WALL MOUNTED FIRE EXTINGUISHER FE
OCCUPANTS
X INCHES/ OCCUPANT .15 (INCHES PER OCCUPANT)
21
3.15"
NOTE: TOTAL WIDTH REQUIRED LESS THAN MINIMUM REQUIRED EXIT WIDTH OF 36" CLEAR
EGRESS TRAVEL DISTANCE
(48" MAX.)
1' - 0"
EXIT CAPACITY REQUIRED
3' - 4"
1
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
10
FE
POINT A
RETAIL TENANT
POINT C
CLEAR
3' - 0"
CLEAR
ROUTE DISTANCE POINT A TO EXIT 1 55'- 3" (<75 MAX DISTANCE TO EXIT) POINT B TO EXIT 1 49'- 10" (<75' MAX DISTANCE TO EXIT) POINT C TO EXIT2 17'- 9" (<75' MAX DISTANCE TO EXIT) MAX COMMON PATH OF TRAVEL PROVIDED = 60'-11" (MAX ALLOW 75') WALL BASE AS SCHEUDLED FINISHED FLOOR AS SCHEUDLED
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
FIRE EXTINGUISHER NOTE:
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
ADA COMPLIANT TYPE "ABC" ALL PURPOSE CHEMICAL FIRE EXTINGUISHER & MOUNTING BRACKET TO BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR AT A HEIGHT OF 4'-0" MAX. SPECIFICATIONS: FIRE EXTINGUISHER: MODEL NO: PART NO: AGENT CAPACITY: U.L. RATING: HEIGHT: BRACKET:
4
BY ANSUL NAMED "SENTRY 10" AA10S 436500 10 LBS. FORAY 4A:80B:C 20.5 IN 435793
FIRE EXTINGUISHER DETAIL SCALE: 1 1/2" = 1'-0"
EGRESS & ACCESSIBILITY PLAN
G-002
RESPONSIBILITY SCHEDULE
SECURITY
TBD
ADT BUSINESS TEX CROMWELL 744 MELROSE AVE NASHVILLE,TN 37211 PH: 615.743.0102 C: 615.779.9872 TEXCROMWELL@ADT.COM
LIGHTING
CAPITAL LIGHT ANGELA McCOY 270 LOCUST STREET HARTFORD, CT 06141 PH: 860-520-2387 C: 860-729-2717 ANGELA.MCCOY@CAPITALLIGHT.COM FIXTURE CONTRACTOR
ICON DESIGN WALTER WROUGHTON 230 SOUTH BEMISTON ST LOUIS, MO 63105 P: 314-725-5721 Ext 102 C: 314-210-3985 WALTERW@ICONFIXTURES.COM DRAPERY FABRIC
BRAD JOBE BESPOKE FURNITURE BRAD JOBE 231 W 29TH ST SUITE 300 NEW YORK, NY 10001 PH: 212-216-9259 BRAD@BRADJOBE.COM CONCRETE FLOORING
UNCONVENTIONAL FLOORING JASON VALENTA PH: 317-281-8223 VALENTAJASON@HOTMAIL.COM
01.
N/A
EX'G
PROVIDE
FURNISH
INSTALL
COMMENTS
10.
GENERAL REQUIREMENTS 1. PERMITS AND FEES
G.C.
G.C.
2. INSPECTION / COORDINATION
G.C.
G.C.
3. SPECIAL INSPECTIONS
DESCRIPTION
X
OWN
OWN
BUILDING PERMIT FEE BY OWNER; CONTRACTOR SPECIFIC PERMITS INCLUDING, FIRE ALARMS, SPRINKLER, PLUMBING & ELECTRICAL BY G.C. ( IF APPLICABLE)
N/A
PROVIDE
FURNISH
INSTALL
LL
LL
LL
G.C. TO ENSURE MOUNTING HEIGHTS AND LOCATIONS ARE CODE COMPLIANT; RELOCATE AS REQ'D
2. STOREFRONT SIGNAGE
OWN
OWN
OWN/VEN
FURNISHED AND INSTALLED BY SIGNAGE VENDOR; G.C. TO SUPERVISE AND COORD. INSTALL
3. DRAPERY
OWN
VEN
G.C.
FURNISHED BY OWN. VENDOR; DELIVERED TO G.C. FOR INSTALLATION
4. LOCKERS
G.C.
G.C.
G.C.
5. SHELVING @ BACK OF HOUSE
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL FROM THE CONTAINER STORE; G.C. TO PROVIDE LAYOUT FROM CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE.
6. ADA TACTILE SIGNAGE
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL PER LOCAL CODE
7. FIRE EXTINGUISHER
G.C.
G.C.
G.C.
AS PER LOCAL CODE AND FIRE DEPARTMENT
X
AUDIO SYSTEM
4. TEMPORARY HEAT
G.C.
G.C.
PLAY NETWORK AUDIO JEFF ROMAN C: 425-629-2760 JROMAN@PLAYNETWORK.COM
5. TEMPORARY ELECTRICAL
G.C.
G.C.
6. WINDOW GRAPHICS
G.C.
G.C.
7. CLEAN UP
G.C.
G.C.
8. INSURANCE
G.C.
G.C.
SHOPPER TRAK
9. JOB PHONE
G.C.
G.C.
1. SALES REFRIGERATOR (REF-1)
OWN
OWN/F.C.
G.C.
OWNER TO PROVIDE REF-1 / F.C. TO STORE AND DELIVER WITH FIXTURE PACKAGE / G.C. TO COORD. INSTALL WITH BAR FIXTURE (F.16)
RETAIL NEXT EDWARD SCHLODDER OFFICE ON THE BEACH 3 LAGOON BEACH DRIVE MILNERTON, SOUTH AFRICA 7441 P: (408) 740-5340 Ext 1035 EDWARD.SCHLODDER@RETAILNEXT.NET
10. FINAL CLEANING
G.C.
G.C.
2. BOH REFRIGERATOR (REF-2)
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL; COORD. W/ MEP'S; COORD. INSTALL WITH BOH SHELVING
02.
G.C.
2. SAW CUT/ DRILL SLAB 3. SIDE WALK PAVERS
BANDWAVE SYSTEMS, LLC ADIL ZAIDI 438 HIGH ST BURLINGTON, NJ 08016 P: 888-396-7182 M: 609-699-4265 AZAIDI@BANDWAVESYSTEMS.COM
4. MALL FLOORING 03.
X X
11.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
FURNISHINGS 1. MILLWORK/FIXTURES & FURNITURE
F.C.
F.C.
G.C.
FLOOR, WALL, & FITTING ROOM FIXTURES FURNISHED BY F.C. / INSTALLED BY G.C.
2. MANAGER'S DESK
G.C.
G.C.
G.C.
G.C. TO FURNISH FROM IKEA AND INSTALL ON TELE/DATA BOARD
AS REQUIRED FOR ELECTRICAL, PLUMBING, & FLOORING
3. MANAGER'S CHAIR
OWN
OWN
OWN/ G.C.
G.C. TO SCHEDULE AND COORD. DELIVERY
4. WALK OFF MATT- ENTRY (REMOVABLE)
G.C.
G.C.
G.C.
NEW REMOVABLE WALK-OFF MAT AT ENTRY
5. AREA RUG (REMOVABLE)
OWN
OWN
OWN
NEW AREA RUG BY OWNER (RETAIL TENANT) AT LOUNGE
G.C. TO CONFIRM SLAB CONDITIONS
2. VAPOR BARRIER
X
G.C.
G.C.
G.C.
3. CONCRETE SLAB
X
G.C.
G.C.
G.C.
G.C. PATCH AND REPAIR FLOOR AS REQUIRED, AND PREPARE FOR NEW FLOOR FINISH
X
G.C.
G.C.
G.C.
ADD ALT: IF LANDLORD DOES NOT PROVIDE SLAB IN-FILL AT LEAVE OUT, G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT; REF. LANDLORD DWGS. FOR REQUIRED SLAB IN-FILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS
G.C.
G.C.
G.C.
5. EXPANSION JOINT MATERIAL
EQUIPMENT
G.C. TO DEMOLISH EXISTING BACK DOOR AND DOOR FRAME, REF PLAN; G.C TO PROVIDE NEW 2-HR RATED CMU PARTITION (UL-U905) W/ RIGID INSULATION, METAL Z-FURRING AND 5/8"THK GYP BOARD AT INTERIOR; REF. PARTITION SCHEDULE FOR DETAILS
CONCRETE SLAB 1. LEVELING OF CONCRETE FLOOR
04.
G.C. TO COORDINATE INSTALL OF WINDOW GRAPHICS WITH OWNER'S VENDOR
12.
1. DEMOLITION
DATA
OWN'S VEN
EXISTING CONDITIONS / SITE WORK
4. CONCRETE SLAB IN-FILL
13.
SPECIAL CONSTRUCTION - N/A
14.
CONVEYING EQUIPMENT - N/A
21.
FIRE SUPPRESSION
22.
LL
LL
LL
PROVIDE
05.
1. STRUCTURAL STEEL
X
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED
B. INTERIOR PARTITIONS
G.C.
G.C.
G.C.
G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS
C. FURRING
G.C.
G.C.
G.C.
G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
2. FIRE ALARM SHOP DRAWINGS AND DEVICES
OLA / MEP ENG
3. MECHANICAL SHOP DRAWINGS AND EQUIPMENT
OLA / MEP ENG
A. TENANT DEMISING WALLS
4. ELECTRICAL EQUIPMENT AND DEVICES
OLA / MEP ENG
5. PLUMBING FIXTURES
OLA / MEP ENG
2. METAL STUDS X
G.C.
A. WATER
G.C.
G.C.
G.C.
NEW WATER PIPES FOR MOP SINK AND WATER COOLER TO TIE-IN TO EXISTING COLD WATER AT BOH; COORD. W/ PLUMBING DWGS
B. WASTE
G.C.
G.C.
G.C.
NEW SANITARY PIPES FOR MOP SINK TO TIE-IN TO EXISTING, COORD. W/ PLUMBING DWGS
C. VENT
G.C.
G.C.
G.C.
2. PLUMBING FIXTURES
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW PLUMBING FIXTURES AT B.O.H.; EXISTING RESTROOM FIXTURES TO REMAIN; COORD. W/ PLUMBING DWGS
3. WATER HEATER
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW WATER HEATER ON SHELF ABOVE MOP SINK; COORD. W. PLUMBING DWGS
G.C.
G.C.
G.C.
EXISTING WATER METER TO REMAIN
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW WATER COOLER; COORD. W/ PLUMBING DWGS
G.C.
G.C.
G.C.
EXISTING ROOFTOP CONDENSER AND AHU TO REMAIN; G.C. TO SERVICE AND CONFIRM FUNCTIONING COORD.. W/ MECHANICAL DWGS.
G.C.
G.C.
G.C.
COORD. W/ MECHANICAL DWGS.
G.C.
G.C.
G.C.
COORD. W/ MECHANICAL DWGS.
LL
LL
G.C.
EXISTING EXHAUST FAN TO REMAIN; G.C. TO RELOCATE AS REQUIRED FOR NEW CEILING LAYOUT; COORD. W/ MECHANICAL DWGS.
X
5. WATER COOLER
23.
A. UNIT
X
OLA / ENG.
3. FRAMING FOR HVAC
7. STOREFRONT SHOP DRAWINGS AND SAMPLES
X
OLA
4. STOREFRONT SYSTEM
8. DOORS AND HARDWARE
OLA
5. METAL DECKING
9. FLOOR FINISH SAMPLES
OLA /RETAIL TENANT
10. PAINT DRAW DOWNS
OLA
1. BLOCKING
G.C.
G.C.
G.C.
G.C. TO COORD. W/ FIXTURE CONTRACTOR
4. FIRE/SMOKE DAMPER
G.C.
G.C.
G.C.
COORD. W/ MECHANICAL DWGS. & LOCAL CODE REQUIREMENTS
11. BOH SHELVING LAYOUT
OLA /RETAIL TENANT
2. SHELVES
G.C.
G.C.
G.C.
G.C TO COORD. ALL MILLWORK REQUIREMENTS W/ FIXTURE CONTRACTOR
5. FIRE STOP / SMOKE BARRIER
G.C.
G.C.
G.C.
COORD. W/ MECHANICAL DWGS. & LOCAL CODE REQUIREMENTS
12. WOOD JOINERY AND MILLWORK
OLA /RETAIL TENANT
4. PLYWOOD
G.C.
G.C.
G.C.
FOR IN-WALL BLOCKING, TELE/DATA BOARD AT BOH
25.
INTEGRATED AUTOMATION - N/A
5. FURRING
G.C.
G.C.
G.C.
G.C TO COORD. ALL MILLWORK BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR
26.
ELECTRICAL G.C.
G.C.
G.C.
COORD. W/ ELECTRICAL DWGS.
06.
G.C. TO PROVIDE A SUBMITTALS SCHEDULE AT CONSTRUCTION KICK-OFF FOR ARCHITECT'S REVIEW
GENERAL NOTES
07.
B. DUCTWORK / DIFFUSERS 2. TEMPERATURE CONTROLS 3. EXHAUST FANS AND GRILLES
CARPENTRY
THERMAL / MOISTURE CONTROL 1. CAULKING
G.C.
G.C.
G.C.
2. SEALANT
G.C.
G.C.
G.C.
3. WATERPROOFING
G.C.
G.C.
G.C.
PROVIDE WATERPROOFING AT ALL WET AREAS
2. G.C. SHALL FILE ANY NECESSARY CERTIFICATES OF INSURANCE WITH THE LOCAL DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED.
4. INSULATION
G.C.
G.C.
G.C.
G.C. TO DEMOLISH EXISTING BACK DOOR AND DOOR FRAME, REF PLAN; G.C TO PROVIDE NEW 2-HR RATED CMU PARTITION (UL-U905) W/ RIGID INSULATION, METAL Z-FURRING AND 5/8"THK GYP BOARD AT INTERIOR; REF. PARTITION SCHEDULE FOR DETAILS
4. G.C. SHALL THOROUGHLY REVIEW ALL EXISTING CONDITIONS PRIOR TO BIDDING. ANY DISCREPANCIES BETWEEN THE BID DOCUMENTS AND EXISTING CONDITIONS SHALL BE BROUGHT THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO BIDDING.
08.
5. G.C. IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.
7. G.C. SHALL INSTALL ALL NECESSARY MEANS TO PROTECT THE PUBLIC , THE BUILDING, AND NEW WORK FROM DAMAGE DURING THE DURATION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO FLOOR PROTECTION, TEMPORARY DUST PARTITIONS AND BARRICADES. 8. G.C. SHALL CONDUCT WORK IN A SAFE AND TIMELY MANNER. PROVIDE AND MAINTAIN ALL NECESSARY GUARDS FOR PREVENTION OF ACCIDENTS. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION, SAFETY ISSUES, CONTROL OR SUPERVISION OF THE WORK, NOR ITEMS RELATED TO STOPPAGE OF WORK. THE AUTHORITY TO STOP WORK REMAINS SOLELY WITH RETAIL TENANT (OWNER) AND G.C.. 9. G.C. SHALL COMPLETE ALL WORK WITHOUT DISRUPTION TO ADJACENT BUILDING TENANTS. 10. G.C. SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. G.C. SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. 11. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING - CREATED OR EXPOSED DURING CONSTRUCTION, PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 12. PRIOR TO PROJECT CLOSEOUT, G.C. SHALL COORDINATE WITH THE BUILDING OWNER: ANY TESTS, SUBMITTAL OF AS-BUILT DOCUMENTATION AS REQ'D, AND ALL REQUIREMENTS FOR PROJECT ACCEPTANCE. 13. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.
X
G.C.
G.C.
G.C.
6. FLASHING
X
G.C.
G.C.
G.C.
G.C. TO INSTALL FLASHING AT CMU WALL INFILL
1. ENTRY DOOR
X
LL
LL
G.C.
SUPPLY NEW 'BEST' 7-PIN SFIC LOCK WITH INTERCHANGEABLE CYLINDER AND 6 SETS OF KEYS
2. RESTROOM DOOR
X
LL
LL
LL/G.C.
G.C. TO REPLACE EXISTING HARDWARE WITH COMPATIBLE BLACK HARDWARE; REF. HARDWARE SCHEDULE
F.C.
F.C.
G.C.
DOOR, FRAME, AND HARDWARE FURNISHED BY F.C. U.N.O. AND INSTALLED BY G.C. SILENCERS AND MIRROR BY G.C. REF. HARDWARE SCHEDULE; G.C. TO COORD. ROUGH OPENING W/ APPROVED SHOP DWGS
LL
LL
G.C.
SUPPLY NEW 'BEST' 7-PIN SFIC LOCK WITH INTERCHANGEABLE CYLINDER AND 6 SETS OF KEYS
G.C.
G.C.
G.C.
DOOR HARDWARE PROVIDED BY G.C., EXCEPT OWNER TO PROVIDE BOH DOOR DEADLOCK & 6 SETS OF KEYS / F.C. TO STORE AND DELIVER WITH FIXTURE PACKAGE / G.C. TO INSTALL LOCK AT BOH DOOR
LL
LL
LL
G.C.
G.C.
X
5. DOOR HARDWARE
6. STOREFRONT SYSTEM 09.
X
G.C.
27.
B. RESTROOM
C. BACK OF HOUSE
G.C.
G.C.
G.C. TO RE-CIRCUIT EXISTING ELECTRICAL PANEL AS REQUIRED; COORD. W/ ELECTRICAL DWGS.
3. TRANSFORMER
X
LL
LL
G.C.
G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; COORD. W/ ELECTRICAL AND STRUCT DWGS.
4. LIGHT SWITCHES
OWN
OWN/VEN
G.C.
SWITCHES PROVIDED BY OWNERS VENDOR; G.C. TO PROVIDE MASTER OVERRIDE SWITCH
5. LIGHT FIXTURES IN CEILING
OWN
OWN/VEN
G.C.
G.C. TO COORD. DELIVERY & INSTALL; COORD. W/ ELECTRICAL DWGS.
X
X X
G.C.
G.C. G.C.
G.C.
G.C. G.C.
G.C.
G.C. G.C.
OWN
OWN/VEN
G.C.
COORD. W/ ELECTRICAL DWGS.
LL
LL
G.C.
EXISTING EXHAUST FAN TO REMAIN; G.C. TO RELOCATE AS REQUIRED FOR NEW CEILING LAYOUT; COORD. W/ MECHANICAL DWGS.
9. EMERGENCY LIGHTING
OWN
OWN/VEN
G.C.
COORD. W/ ELECTRICAL DWGS.
11. DISCONNECT SWITCH
G.C.
G.C.
G.C.
COORD. W/ ELECTRICAL DWGS.
12. TIME CLOCK
G.C.
G.C.
G.C.
MULTI-CHANNEL, 24/7 PROGRAMMABLE TIME CLOCK; COORD. W/ ELECTRICAL DWGS.
13. FLOOR OUTLETS
G.C.
G.C.
G.C.
G.C. TO PROVIDE DEDICATED FLOOR BOX; G.C. IS RESPONSIBLE FOR ANY TRENCHING OR CORING, PATCHING AND REPAIRING OF THE FLOORING REQUIRED FOR INSTALLATION OF THE FLOOR BOX.
1. CONDUIT FOR COMPUTER SYSTEM
G.C.
G.C.
G.C.
COORD. W/ BRAND WAVE
2. TELEPHONE CONDUIT
G.C.
G.C.
G.C.
3. TELEPHONE JACKS/SETS/WIRES
G.C.
G.C.
G.C.
4. AUDIO SYSTEM - SPEAKERS AND CONTROLS
G.C.
G.C.
G.C./ OWN
CONDUIT & PULL STRINGS BY G.C. AS REQ'D; G.C. TO SCHEDULE & COORD. INSTALL W/ VEND
OWN
OWN
G.C.
THERE ARE NO POINT-OF SALES OR SERVICE COUNTERS IN THIS STORE. RETAIL TENANT STORES ARE DESIGNED AND OPERATE AS SHOWROOMS. MO MERCHANDISE IS SOLD ON LOCATION.
OWN
OWN
G.C.
G.C. TO PROVIDE PULL STRING AS REQ'D; COORD. W/ VENDOR
1. CAMERA SECURITY SYSTEM
OWN
OWN
G.C.
RETAIL TENANT VENDOR FURNISHES & INSTALLS CAMERA WIRING, CAMERA, & CPU; G.C. TO PROVIDE CONDUIT & PULL, SCHEDULE AND COORD. W/ VENDOR
2. LIFE SAFETY
G.C.
G.C.
G.C.
A. FIRE ALARM
G.C.
G.C.
G.C.
MODIFICATION TO EXISTING SYSTEM TO TIE-IN TO EXISTING LANDLORD FIRE ALARM CONTROL PANEL AT ELECTRICAL ROOM BEHIND TENANT SPACE; COORD. W/ APPROVED FIRE ALARM DWGS.
B. SMOKE DETECTORS
G.C.
G.C.
G.C.
SEE ELECTRICAL AND MECHANICAL DWGS.
EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO GRIND, STAIN, POLISH AND SEAL; ADD ALT: PROVIDE NEW VAPOR BARRIER UNDER SLAB INFILL IF SLAB INFILL NOT PROVIDED BY LANDLORD
28.
ELECTRONIC SAFETY AND SECURITY
EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO GRIND AND SEAL
G.C.
G.C.
G.C. TO COORD. IN-WALL BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR
G.C.
G.C.
G.C.
G.C. TO PATCH W/ MOISTURE RESISTANT GYP. BOARD AS REQ'D; COORD. W/ MEP
C. BACK OF HOUSE
G.C.
G.C.
G.C.
D. MOP SINK
G.C.
G.C.
G.C.
X
X
6. SHOPPER TRACK SYSTEM
EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO GRIND, STAIN, POLISH AND SEAL; ADD ALT: PROVIDE NEW VAPOR BARRIER UNDER SLAB INFILL IF SLAB INFILL NOT PROVIDED BY LANDLORD
G.C.
B. RESTROOM
X
INSTALL WATERPROOF PLASTEX POLYWALL UP TO 48" AFF MIN.,; ENSURE MOISTURE RESIST. GWB IS INSTALLED IN AND AROUND WET AREAS
4. BASE
KEY
DESCRIPTION
G.C. (OR) GC
GENERAL CONTRACTOR
OWN. (OR) OWN
OWNER / RETAIL TENANT
LL
LANDLORD
F.C. (OR) FC
FIXTURE CONTRACTOR
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW PAINTED WOOD BASE
B. RESTROOM
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW PAINTED WOOD BASE
AV
AUDIO/VISUAL CONSULTANT
C. BACK OF HOUSE
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW RUBBER WALL BASE
X
N/A OR EXISTING
N/A
NOT APPLICABLE-DOES NOT APPLY TO PROJECT
A. STOREFRONT DISPLAY WINDOW
G.C.
G.C.
G.C.
NEW GYP. BOARD CEILING
EX'G
EXISTING - ALREADY LOCATED ON SITE
B. CASUAL/TAILORED SHOP
G.C.
G.C.
G.C.
OPEN TO EXISTING DECK ABOVE; G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED
PROVIDE
TO FURNISH & INSTALL ( WHEN TENANT RESPONSIBILITY, TENANTS SUPPLIERS TO FURNISH & INSTALL)
C. LOUNGE/ VEST/ FITTING ROOMS / TRANSITIONS/ RESTROOM
G.C.
G.C.
G.C.
FURNISH
TO SUPPLY AND DELIVER
INSTALL
TO INSTALL
D. BACK OF HOUSE
G.C.
NEW GYP. BOARD CEILING; AT RESTROOM ONLY DEMOLISH EXISTING ACT CEILING AND 2x4 LIGHT; PRIOR TO INSTALL OF NEW GYP. BOARD CEILING; (DEDUCT ALT: EXISTING ACT CEILING AND LIGHT TO REMAIN; CONFIRM WITH TENANT PRIOR TO DEMO ) OPEN TO EXISTING DECK ABOVE; G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED
OWN/VEN
OWNER'S VENDOR
G.C.
G.C.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
RESPONSIBILITY SCHEDULE LEGEND
A. SALES AREA / VESTIBULE/ FITTING ROOMS
5. CEILING
STAMP
COMMUNICATIONS
3. WALLS
A. SALES AREA / VESTIBULE / FITTING ROOMS/
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
X
5. POS SYSTEM
2. FINISH FLOORING A. SALES AREA / VESTIBULE / FITTING ROOMS
G.C.
8. EXHAUST FAN
FINISHES 1. GYPSUM FOR PARTITIONS
X
6. LIGHT FIXTURES IN MILLWORK
DOORS / OPENINGS
4. BACK EXIT DOOR
2. PANELS
7. EXIT SIGNAGE
5. METAL CLADDING
3. BACK OF HOUSE DOOR
6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE HIGHEST QUALITY INDUSTRY STANDARDS FOR MATERIAL AND INSTALLATION. ALL WORK WILL BE WARRANTIED FOR ONE YEAR MIN. BY THE G.C. UNLESS STATED OTHERWISE. REPAIR OR REPLACEMENT OF WARRANTIED WORK AND ANY AREA AFFECTED BY FAILURE OF WARRANTIED ITEM SHALL BE THE G.C.'S RESPONSIBILITY.
X
1. DISTRIBUTION
1. G.C. SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS, FEES, APPROVALS, AND TEST FOR THE WORK. ALL CONSTRUCTION AND MATERIALS SHOULD COMPLY WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS / LAWS / CODES.
3. ALL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP.
STRUCTURAL ENGINEER
1. HVAC
X
X
LICENSE # C-4550
HEATING, VENTILATING, AND AIR-CONDITIONING
6. STRUCTURAL SHOP DRAWINGS
X
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
MODIFICATION OF EXISTING SYSTEM FOR NEW TENANT LAYOUT; COORD. W/ APPROVED SPRINKLER DWGS.
G.C.
4. WATER METER
REF. STRUCTURAL DWGS; G.C. TO ENSURE FIRE-PROOFING RATING FOR EXISTING STRUCTURE IS MAINTAINED/REPLACED
G.C.
CASE ENGINEERING, INC.
1. PIPING
INFILL AT BACK WALL TO BE EXISTING BY LANDLORD
G.C.
OLA / MEP ENG.
MEP ENGINEER
PLUMBING
METALS
1. SPRINKLER SHOP DRAWINGS AND DEVICES
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
ENGINEERING
G.C. REQUIRED SHOP DRAWINGS N/A
OWNER'S REPRESENTATIVE
OSBORN G.C.
X
2. CONCRETE MASONRY BLOCK
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
TM
1. SPRINKLER SYSTEM
MASONRY 1. BRICK
DESCRIPTION
COMMENTS
SPECIALTIES 1. TOILET ROOM ACCESSORIES
SPECIAL INSPECTOR CONTRACTED BY OWNER; G.C. TO COORD. SCHEDULE AND ACCESS TO SITE FOR INSPECTIONS
EX'G
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
DESCRIPTION
SIGNAGE
ARCHITECT
RESPONSIBILITY SCHEDULE
RETAIL TENANT
REQUIRED VENDORS CONTACT INFO
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
RESPONSIBILITY SCHEDULE
G-003
ARCHITECT
61' - 10"
3' - 9 3/4"
1' - 10"
LEASE LINE TO LEASE LINE
VESTIBULE 06
7' - 11 3/8"
7' - 3 3/4"
B
2' - 1 7/8"
A 11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
16 13
15
TYP. 6
5' - 8 3/4"
5' - 6"
29' - 3"
VIF
2 1/2"
1 2
1 3
2' - 5"
3 5/8"
1
D
8
TYP.
TYP.
14 TYP.
12 A-501
D
3' - 9"
8
D
ADA FITTING ROOM 05
6' - 11 3/8"
HOLD
14
14
18
2' - 5"
5
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
DISPLAY WINDOW 02
10
8
1
24' - 10"
2 A-300
TM
ALIGN
D
18
TYP.
12' - 9 5/8"
STRUCTURAL ENGINEER
A-300
1
D
1' - 1"
14
A
BOH 08
7 C
3
ALIGN
4' - 10"
A-304
HOLD
1
8
14
1
4
2' - 6"
9
4' - 10"
TYP.
6' - 11"
9
3' - 2"
HOLD
6' - 6 1/8"
3
4' - 5" HOLD
D
HOLD
5
14
2
HOLD
3' - 0"
10
1
24' - 10"
9"
HOLD
A-302
1' - 10 1/2"
13' - 10 3/4"
12' - 4 3/4"
C
2
LICENSE # C-4550
1' - 4 5/8"
6' - 9"
A-301
9' - 5 7/8"
8
V.I.F.
9' - 6 5/8"
2
CASUAL/ TAILORED SHOP 03
HOLD
7' - 0"
LOUNGE 04
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
ENTRY 01
6
15' - 4 3/4"
A-303
20' - 2 3/4"
ABV.
19' - 2 1/4"
18' - 0 5/8"
4 TYP.
19 2
14
ALIGN
24' - 2 3/4"
A
CASE ENGINEERING, INC. 7
EX-01 2' - 11"
D
MEP ENGINEER
RETAIL TENANT
TYP.
3' - 0"
1
LEASE LINE TO LEASE LINE
4"
18
1' - 10 1/2" 2 1/2"
5 1/8"
10" 7' - 0"
6
B
TYP.
20' - 10"
A-305
14
8
6' - 0"
4
D
9
14
C
HOLD
EX-02
ALIGN
04 24
3' - 0"
17
ALIGN
2
8"
2 1/2"
21
6' - 6"
4
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1' - 6"
DOOR
EX-03
A-304
4"
23
7' - 4"
11
4' - 10"
22
8
3' - 0"
V.I.F.
E 12
LEASELINE TO LEASELINE
18
TYP.
OWNER'S REPRESENTATIVE
9
5
27' - 4"
14
6' - 7 1/8" HOLD
HOLD
2' - 6" 20
3' - 7 1/2"
3' - 4 1/4"
1' - 8 3/8" 3 5/8"
15
5' - 7"
1' - 9"
2 A-501
NORTH
CONSTRUCTION PLAN SCALE: 1/4" = 1'-0"
CONSTRUCTION PLAN SYMBOL / HATCH SYMBOL / HATCH
DESCRIPTION EXISTING PARTITION TO REMAIN
NEW PARTITION
SOUND RATINGS REQUIREMENTS GENERAL NOTES: 1. ALL PENETRATIONS INTO SOUND RATED PARTITIONS OR FLOOR-CEILING ASSEMBLIES SHALL BE SEALED, LINED, OR INSULATED WITH AN APPROVED PERMANENT RESILIENT SEALANT.
1. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLAN(S) AND EXISTING CONDITIONS.
2. ALL RIGID CONDUITS, DUCTS, PLUMBING PIPES, AND APPLIANCE VENTS LOCATED IN SOUND RATED ASSEMBLIES SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES, MOUNTS, OR A MINIMUM 1/4" THICK APPROVED RESILIENT MATERIAL.
2. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER.
3. AN APPROVED PERMANENT AND RESILIENT ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR AND THE SEPARATION WALLS.
ROOM NAME 01
ROOM TAG
101
DOOR TAG
4. METAL VENTILATING AND CONDITIONED AIR DUCTS LOCATED IN SOUND RATED ASSEMBLIES SHALL BE LINED (EXCEPTION: DUCTS SERVING ONLY EXIT WAYS, KITCHEN COOKING FACILITIES, AND BATHROOMS NEED NOT BE LINED).
PARTITION TYPE TAG, REF. A-600
5. MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES WHENEVER A PLUMBING, PIPING, OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR BEYOND THE PIPE OR DUCT. THIS REQUIREMENT IS NOT APPLICABLE TO FIRE SPRINKLER PIPE, GAS LINE OR ELECTRICAL CONDUIT.
A
1 A-101
1 A-101
1 A-101
ELEVATION TAG
CONSTRUCTION PLAN GENERAL NOTES:
6. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24" AND NOTE THAT BACK AND SIDES OF BOXES SHALL BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKED BY A MINIMUM OF 2" THICK MINERAL FIBER INSULATION.
CONSTRUCTION PLAN KEY NOTES: 1
LEASE LINE
2
EXISTING 2-HR FIRE-RATED CMU DEMISING WALL TO REMAIN; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH
3
EXISTING METAL 2" FURRING PARTITION TO REMAIN; G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND PREP FOR NEW PAINT FINISH
4
EXISTING KNEE WALL AT STOREFRONT TO REMAIN; G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND PREP FOR NEW PAINT FINISH
5
EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION
6
EXISTING THRESHOLD AT STOREFRONT ENTRY TO REMAIN; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)
7
EXISTING STOREFRONT ENTRY DOOR AND HARDWARE TO REMAIN; G.C. TO PROVIDE NEW BESTLOCKS; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION; REF A-601 FOR DOOR AND HARDWARE SCHEDULE
3. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL OR COLUMN U.N.O. DO NOT SCALE DRAWINGS UNDER ANY CIRCUMSTANCES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER THE SCALE ON THE DWGS. 4. LL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. TO REMAIN MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP. 5. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING CONSTRUCTION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE.
STAMP
6. G.C. TO USE 5/8" TYPE 'X' GYPSUM BOARD THROUGHOUT PROJECT. 7. ALL OUTSIDE CORNERS AT DRYWALL PARTITIONS AND FURRING TO HAVE METAL CORNER BEADS. TAPE, PLASTER, AND SAND SMOOTH. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP.
7. NO WALL FURNACE SHALL BE INSTALLED IN SOUND RATED PARTITIONS.
DETAIL SECTION TAG
DETAIL CALLOUT TAG
8. NO ELECTRICAL PANEL SHALL BE INSTALLED IN SOUND RATED PARTITIONS.
8. ACCESS PANELS IN WALL / CEILING FOR PLUMBING, MECHANICAL, ELECTRICAL ACCESS SHALL BE FLUSH FRAMELESS SQUARE CORNER GYP. BOARD PANELS, SEE RCP A-102 FOR SPECIFICATION.
8
NEW PARTITION TO DECK; REF. A-600 FOR PARTITION SCHEDULE
9. CEILING ASSEMBLY TO MEET 50 51C AND 50 11C SOUND RATING REQUIREMENTS.
9. METAL STUDS SHALL EXTEND UP TO THE DECK ABOVE WHERE NOTED AND APPLICABLE.
9
NEW PARTIAL HEIGHT PARTITION; REF. A-600 FOR PARTITION SCHEDULE
10. PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADERS AND JAMBS, AND AS REQUIRED TO MAKE ASSEMBLY RIGID.
10
NEW WATER COOLER; COORD W/ PLUMBING DWGS.
11
NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN A.F.F. AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT/BRACING AS REQ'D ; COORD. WITH MEP DRAWINGS.
12
NEW MOP SINK AND FAUCET; REF TO A-101 FOR SPEC; COORD. W/ MEP DWGS; REF. ELEVATIONS
13
EXISTING RESTROOM TOILET AND SINK BY LANDLORD; COORD. W/ MEP DWGS.
12. FOR ALL WOOD MEMBERS REQUIRED BY CODE TO BE FIRE-RETARDANT TREATED, PROVIDE PRESSURE IMPREGNATION WITH FIRE-RETARDANT CHEMICALS TO PROVIDE UL PRS FIRE HAZARD CLASSIFICATION. ALL SUCH WOOD MEMBERS SHALL BE IDENTIFIED WITH A UL LABEL.
14
G.C. TO PROVIDE FRT PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND FIXTURE CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION
13. G.C. TO COORD. NEW WORK W/ RCP.; REF. A-102 RCP FOR SOFFIT / LIGHTING INFORMATION.
15
G.C. TO USE MOISTURE-RESISTANT TYPE "X" GYP. BOARD AT THE WALLS IN WET AREAS, INCLUDING AROUND THE VICINITY OF THE MOP SINK, TYP.
16
15. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS.
G.C. TO PROVIDE PLASTEX POLYWALL WATERPROOF PANEL UP TO 48" AFF BEHIND AND AROUND MOPSINK, REF. ELEVATIONS; REF. A-104 FOR SPEC.
17
EXISTING ELECTRICAL PANEL TO REMAIN; G.C. TO RE-CIRCUIT AS REQ'D; COORD. W/MEP DWGS
16. FIRE EXTINGUISHERS SHALL BE INSTALLED AS REQ'D BY LOCAL AUTHORITY HAVING JURISDICTION.
18
EXISTING 1-HR FIRE-RATED DEMISING WALL; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH
19
EXISTING SUSPENDED AHU ABOVE; COORD. W/ MEP DWGS
20
INFILL AT BACK WALL TO BE EXISTING BY LANDLORD
21
G.C. TO SUSPEND EXISTING TRANSFORMER ABOVE; COORD. W/ ELECTRICAL AND STRUCTURAL DWGS
22
G.C. TO RELOCATE EXISTING DISCONNECT SWITCH NEXT TO NEW SWITCH; COORD. W/ MEP DWGS
23
G.C. TO PROVIDE NEW DISCONNECT SWITCH; COORD. W/ MEP DWGS.
24
NEW CUSTOM DOOR FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE SILENCERS AND MIRROR; G.C. TO COORD. ROUGH OPENING DIMENSIONS WITH APPROVED FINAL SHOP DWGS.
11. G.C. SHALL SUPPLY AND INSTALL PROPER AND ADEQUATE BLOCKING TO SUPPORT ALL OWNER SUPPLIED AND MILLWORK APPLIED/INSTALLED ITEMS FOR FIRM, LEVEL, AND SECURE INSTALLATION OF SUCH ITEMS ON WALLS, COLUMNS, ETC. IF REQUIRED BY CODE ALL SUCH BLOCKING AND SUPPORTS SHALL BE FIRE RETARDANT TREATED TO MEET SUCH REQUIREMENTS. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE IN COMPLIANCE WITH IBC SECTION 2304.9.5.
14. G.C. TO COORD. NEW WORK W/ FIXTURE PLAN. REF. A-101 FIXTURE PLAN FOR FIXTURE INFORMATION.
17. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING - CREATED OR EXPOSED DURING CONSTRUCTION,PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 18. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UL STANDARDS FOR THROUGH PENETRATION FIRESTOP SYSTEMS. THE G.C. SHALL SUBMIT SHOP DRAWING DETAILS THAT THE INSPECTOR MAY REQUIRE. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES CLEARLY DEFINED. 19. ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING THERMAL INSULATION - CREATED OR EXPOSED DURING CONSTRUCTION - SHALL BE RESTORED TO FULL CAPACITY. 20. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
C 10 3/4"
ADA RESTROOM 07
4 A-306
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
CONSTRUCTION PLAN
A-100
ARCHITECT
61' - 10"
PL.05 PL.04
2
UH
CAB
B EQ
3
A
EQ 1
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
MR PL.01
FB-01
8
A.03
10
3'
4
F.12
TYP.
5 10
3' - 0"
3' - 0"
A.02
SO
MIN.
3' - 0"
F.21
F.06
4
10
7
FE
MQ
MQ
HS
11
F.23 ABV.
12
A.03 MQ
F.03
F.01
A.05
STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
10
F.01 1
6"
ADA FITTING ROOM 05
6' - 0"
F.11A
MQ
A.04
BENCH
5
SB
F.11
FB-01
LICENSE # C-4550
DISPLAY WINDOW 02
2' - 4 1/8" VIF
CT
4
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
MQ
3' - 1"
A.05
CASE ENGINEERING, INC. ENTRY 01
F.06
CPT-01
3' - 0"
TYP.
F.11A
2" 1/3 1 -
5
4
BS
CPT-02
LEASE LINE TO LEASE LINE
LOUNGE 04
MEP ENGINEER
20' - 10"
REF-1
8
F.01
V.I.F. PLATFORM
A.04
5
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
9' - 0 7/8"
TDSH
9' - 0"
F.22
A.05
FDSK
MIN
1
F.16
TYP.
F.19
F.06
CASUAL/ TAILORED SHOP 03
BS CH-1
CB
10"
MIN.
FB-01
4
1"
5
F.15
F.03
3' - 0"
F.22
A.05 CH-1 A.04
4
F.01
3' - 2 1/4"
4' - 0"
3 A-400
9
F.01
3' - 9"
1' - 0 1/2"
A.01
5
PL.06
EQ
D.08
6
KB
EQ.
TYP.
EQ
SH16 BR B16 SHBH SHB
EQ
3' - 9"
2' - 4"
4 5
SH16
EL
1
10"
4 TYP.
REF-2
BOH 08
OWNER'S REPRESENTATIVE
F.01
VESTIBULE 06
TPH
4' - 8" 14
PL.03
GB
5
SD TD
3' - 2 13/16 "
2' - 4"
PL.02
RETAIL TENANT
FE
4
EQ
NORTH TYP.
EQ
6"
2' - 6"
1
V.I.F.
FIXTURE PLAN SCALE: 1/4" = 1'-0"
FIXTURE PLAN SYMBOL / HATCH SYMBOL / HATCH
DESCRIPTION
EXISTING PARTITION TO REMAIN
NEW PARTITION ROOM NAME 01
X.01
ROOM TAG
FIXTURE TAG
FIXTURE PLAN GENERAL NOTES: 1. REFER TO FINISH SCHEDULE A-104 FOR FINISH DESCRIPTIONS AND SPECIFICATIONS. 2. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES. 3. G.C. & F.C. TO COORDINATE CONSTRUCTION & INSTALLATION MATERIALS, METHODS, AND SCHEDULING OF FIXTURES. 4. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS. 5. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP. 6. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING. G.C. TO COORDINATE WITH SHOP DRAWINGS TO BE PROVIDED BY THE FIXTURE CONTRACTOR. 7. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS. 8. FINISHES TO BE FIRE RATED AS REQUIRED BY STATE/LOCAL BUILDING CODES. 9. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND MILLWORK. COORDINATE CONSTRUCTION DETAILS AND DIMENSIONS WITH FIXTURE PLANS AND FIXTURE SHOP DRAWINGS. 10. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES. 11. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS. 12. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES. 13. THERE ARE NO POINT-OF SALES OR SERVICE COUNTERS IN THIS STORE. RETAIL TENANT STORES ARE DESIGNED AND OPERATE AS SHOWROOMS. MO MERCHANDISE IS SOLD ON LOCATION.
FIXTURE SCHEDULE TAG
DESCRIPTION
DIMENSION
RESPONSIBILITY
MANUFACTURER / MODEL
FINISH
QTY.
A.01
3-WAY MIRROR
62"W x 1 1/2"D x 90"H
F.C./G.C.
F.C./G.C.
GL-02 / MT-01
1
A.02
FLAT MIRROR
24"W x 72"H
F.C./G.C.
F.C./G.C.
GL-02 / MT-01
1
A.03
TALL FLAT MIRROR
24"W x 78"H
F.C./G.C.
F.C./G.C.
GL-02 / MT-01
2
A.04
FITTING ROOM HANG BAR
A.05
VALET PEG
FIXTURE PLAN KEY NOTES:
EQUIPMENT SCHEDULE
1" SQ. x 3"D x 30"L w/ 2 1/2" SQ. MOUNTING PLATES 1" SQ. x 3"D HOOK w/ 2 1/2" SQ. MOUNTING PLATE
F.C. F.C.
F.C.
MT-01
F.C.
MT-01
4 15
F.01
LADDER FIXTURE - TYP.
62"L x 18"W x 81"H
F.C.
F.C.
MT-01 / WD-01
6
F.03
FREE-STANDING SHELF
133 1/2"L x 24"W x 67 1/2"H
F.C.
F.C.
MT-01 / WD-01
2
F.06
FREE-STANDING RACK
24"W X 38"L X 63"H
F.C.
F.C.
MT-01
4
F.10
MANNEQUIN RISER
18"L x 14"W x 12 1/4"H
F.C.
F.C.
WD-01
2
F.11
NESTER TABLE
67 1/2"L x 24"W x 28"H
F.C.
F.C.
WD-01
1
F.11A
NESTER CUBE
30"L x 30"W x 18"H
F.C.
F.C.
WD-01, MT-01
2
F.12
ADA BENCH
42"L x 20"W x 17"H
F.C.
F.C.
WD-01
1
F.15
UNDERWEAR FIXTURE
29"L x 16"W x 30"H
F.C.
F.C.
WD-03, MT-01
1
F.16
BAR
60"L x 33"W x 39"H
F.C.
F.C.
WD-03
1
F.19
SMALL TABLE
66"L x 30"W x 30"H
F.C.
F.C.
WD-02
1
F.21
SMALL ROUNDER
42"Ø x 30"H
F.C.
F.C.
WD-03
1
F.22
FITTING ROOM UNIT
REF. PLANS
F.C.
F.C.
MT-01 / WD-01
2
F.23
DISPLAY PLATFORM
REF. PLANS
F.C.
F.C.
WD-01
1
NOTES / REMARKS
FINISH: GL-02, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-02) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC FINISH: GL-02, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-02) BY G.C.; VERIFY DIMS. FINISH: GL-02, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-02) BY G.C.; VERIFY DIMS. FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. FINISH: MT-01 ; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01, WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01, WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; RIGHT SIDE MOUNTED FINISH: WD-03, MT-01 FINISH: WD-03 (WALNUT); REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-02 (HICKORY); REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-03 (WALNUT); REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01, WD-01; G.C. TO CONFIRM FIELD DIMENSIONS AND COORD. W/ F.C. FINISH: WD-01 (WHITE OAK); REF. FIXTURE PACKAGE FOR MORE DETAILS
TAG
DESCRIPTION
DIMENSION
RESPONSI BILITY
MANUFACTURER
MODEL
FINISH
QTY.
16"
G.C.
THE CONTAINER STORE
ELFA WHITE VENTILATED SHELF BRACKETS
WHITE METAL
19
WALL MOUNTED SHELVING BRACKET WALL MOUNTED STANDARD TOP TRACKS WALL MOUNTED STANDARD
VARIES
G.C.
THE CONTAINER STORE
ELFA HANG TOP TRACKS
WHITE METAL
8
84"H
G.C.
THE CONTAINER STORE
ELFA HANG STANDARD
WHITE METAL
19
CB
COAT HANG BAR
20"L X 1 3/8"D X 2 3/4"H
G.C.
EL
EMPLOYEE LOCKER FOLDING WALL MOUNTED DESK
12"W x 18"D x 72"H
G.C.
THE CONTAINER STORE - UMBRA; ULINE
36"L X 18"D X 30"H
G.C.
IKEA
FLIP HOOK BAR; SKU : 10054165 H-1845GR BJURSTA WALL MOUNTED DESK
REF. PLANS; G.C. TO CUT LENGTHS IN FIELD AS REQ'D
G.C.
ARAKAWA
CRB 1800-A
G.C.
MMF INDUSTRIES
201202889
F.C./G.C.
FAGOR
MODEL BC-112
G.C.
DANBY
G.C.
B16 BR BST
FDSK HS KB REF-1 REF-2 SH16 SHB SHBH
HANGING SYSTEM MERCHANDISING TRACK KEY BOX SALES FLOOR REFRIGERATOR BOH REFRIGERATOR
11.7"H x 7.9"W x 3.6"D 23 1/2"W x 23 1/2"D x 34"H 20 5/8"W x 20 7/8"D x 32 3/4"H
WALL MOUNTED 16"D (LENGTH VARIES) VENTILATED SHELF WALL MOUNTED SHELVING 36"L, 48"L HANG BAR HANG BAR HOLDER 3"H X 2"D
COORD. INSTALL WITH BOH SHELVING
THE CONTAINER STORE
ELFA WHITE VENTILATED SHELVES
WHITE METAL
8
G.C.
THE CONTAINER STORE
ELFA CLOSET ROD
WHITE METAL
8
G.C.
THE CONTAINER STORE ELFA CLOSET ROD HOLDER WHITE METAL BLACK STATIC VIDEO MOUNT VENTED DATA SHELF RESISTANT PRODUCTS VMP-ER-S2UV POWDER COAT CASABELLA - GROOK BLACK/ALUMIN UTILITY HOLDER; SKU : THE CONTAINER STORE UM 10055909
16
TDSH
TELE/DATA SHELF
19"L x 14 3/4"D x 4"H
G.C.
UH
UTILITY HOLDER
10"L x 4"D x 2 3/4"H
G.C.
FITTING ROOM STOOL
16"W x 16"D x 30"H
CPT-02
WALK-OFF MAT
36"W X 72"L X 3/8"H
CT
COFFEE TABLE
60"L x 19"D x 14"H
FB-01
FITTING ROOM CURTAIN
REF. PLANS
MQ
MANNEQUIN
3/4 MALE TORSO
SB
SUITING BENCH
48"L x 19"D x 14"H
SO
SOFA
86"L X 36"D
1
NOT INSET; REMOVABLE AREA RUG
CATALINA OLEFIN - 1462-M-36 THK CHARCOAL --
1
NOT INSET; REMOVABLE WALK-OFF MAT
BRAD JOBE
3
TBD
9
G.C. TO COORD. INSTALLATION W/ BRAD JOBE; CURTAIN SUSPENDED FROM RODS AND RINGS -
--
1
FINISH TBD
--
1
PL.04
SERVICE SINK
PL.05
SERVICE SINK FAUCET
PL.06
WATER COOLER
1
DIMENSION 20 1/2"W X 18 1/4"D
RESPONSI BILITY MANUFACTURER LANDLORD AMERICAN STANDARD
CH-1
TBD
1
LEASE LINE
2
NEW MOP SINK AND FAUCET; COORD. W/ MEP DWGS.
3
EXISTING RESTROOM PLUMBING FIXTURES AND ACCESSORIES TO REMAIN; COORD. W/ MEP DWGS. G.C. TO PROVIDE NEW WALL MOUNTED CABINET
4
G.C. TO PROVIDE FIRE RATED PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND FIXTURE CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION.
5
NEW B.O.H. CONTAINER STORE ELFA SHELVING; G.C. TO COORD. INSTALLATION W/ MANUFACTURER; G.C. TO VERIFY SITE DIMENSIONS AND SUBMIT A PROPOSED LAYOUT FROM THE CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION.
6
NEW TELE/DATA BOARD BY G.C. (3/4" FRT PLYWOOD) MOUNTED TO WALL AT B.O.H. AND PAINTED TO MATCH ADJ. FINISH
7
NEW DRAPERY PANEL INSTALLED ON TAPED-IN RECESSED CURTAIN TRACK AT ADA FITTING ROOM OPENING; B.O. OPENING AT 7'-0" AFF; FINISH TRACK WHITE; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS
8
NEW DRAPERY PANEL INSTALLED ON RODS AND RINGS AT FREE-STANDING FITTING ROOMS; RODS AND RINGS TO BE INSTALLED DURING ASSEMBLY OF FREE-STANDING FITTING ROOM FIXTURES (F.22); G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS
9
3-WAY MIRROR (A.01) W/ LIGHTING ABOVE; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; G.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND RCP
10
MIRROR (A.03); B.O. FRAME MOUNTED @ 10" AFF; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; G.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS.
11
MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD, REF. A-102B FOR DIMENSIONS; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.
STAMP
PROVIDE END CAPS AS REQ'D
1 1
PLUMBING SCHEDULE
DIMENSION 15"Ø x 27"H
120"W x 96"L
3
1
DESCRIPTION BAR STOOL
AREA RUG
MATCH ADJ. PT-01C
BLACK
TAG BS
CPT-01
1
DCR044A2BDD
PL.03
2
WHITE
COORD. INSTALL WITH BAR F.16
ADDITIONAL FURNITURE / FIXTURE SCHEDULE
--
1
1
EXISTING RESTROOM SINK 2 "W X 5 1/2"D X 6 3/4"H LANDLORD AMERICAN STANDARD SELECTRONIC 6055.102 FAUCET EXISTING RESTROOM 17 1/2"W X 30 5/8"D X 30 LANDLORD AMERICAN STANDARD ASTUTE VORMAX 727AA.121 TOILET 11/16"H
NOTES / REMARKS
GRAY
1
PL.02 QTY. 3
-
PUTTY BLACK/ALUMIN UM
DESCRIPTION EXISTING RESTROOM SINK
MANUFACTURER --
1
COORD. INSTALL WITH BOH TELE/DATA BOARD; REF. ELEVATIONS CEILING RECESSED MERCHANIDISING TRACKS; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND POWDERCOAT TO MATCH ADJ. FINISH COORD. W/ TELE/DATA BOARD
TAG PL.01
RESPONSIBLITY OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT) OWNER (RETAIL TENANT)
NOTES / REMARKS
MODEL LUCERNE 0356.041
FINISH WHITE
CHROME
QTY NOTES / REMARKS EX G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. EX COORD. W/ MEP DWGS.
WHITE
21"W X 21 1/2"D X 44 1/2"H 8" SPREAD
G.C.
TURBO AIR
TSA-1MOP
G.C.
B-0674-RGH
11 3/4"W x 14 1/2"D x 50"H
G.C.
T&S BRASS AND BRONZE WORKS, INC. QUENCH
STAINLESS STEEL CHROME
Q7 FREESTANDING
BLACK
EX G.C TO SPECIFY RIGHT HANDED LEVER; G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS. 1
COORD. W/ MEP DWGS.
1
COORD. W/ MEP DWGS.
12
NEW STOREFRONT DISPLAY PLATFORM (F.23) BY F.C.; G.C. TO VERIFY SITE DIMENSIONS AND COORD. INSTALL W/ F.C.
13
NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN. A.F.F. AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT OR BRACING AS REQUIRED; COORD. WITH MEP DRAWINGS.
14
EXISTING ELECTRICAL PANEL TO REMAIN; G.C. TO RE-CIRCUIT AS REQ'D COORD. W/ MEP DWGS
DESCRIPTION WALL CABINET
CH
COAT HOOK
GB
EXISTING ADA GRAB BARS
MR
EXISTING RESTROOM MIRROR
SD TD TPH
DIMENSIONS 23.2"W x 12.2"" x 23.4
RESPONSIBILITY G.C.
MANUFACTURER TOPEAKMART
MODEL 23" x 23" 2 DOOR WALL MOUNT CABINET
FINISH WHITE
1 1/4" W x 1 1/8" D x 1 1/4" H 18"L, 36"L, 42"L
LANDLORD
BOBRICK
B-233
LANDLORD
BOBRICK
B-6806-18, B-6806-36, B-6806-42
18"W X 36"H
LANDLORD
BOBRICK
B-165 1836
STAINLESS STEEL POLISHED STAINLESS STEEL BRUSHED STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL CHROME
EXISTING SOAP 6 1/8"L x 7"W x 3 5/16"D DISPENSER EXISTING RECESSED 19"H X 13"W X 4 1/4"D PAPER TOWEL DISPENSER EXISTING TOILET PAPER 6"W X 4 1/4"D X 2 3/4"H HOLDER
LANDLORD
BOBRICK
B-4112
LANDLORD
BOBRICK
B-35903
LANDLORD
BOBRICK
B-264
QTY NOTES / REMARKS 1 FINISH: WHITE; G.C. TO PROVIDE AND INSTALL, CENTERED ABOVE W.C. AT 4'-3" AFF EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS
EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX RECESSED INTO WALL EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: JO CHECKED BY: Checker AREA: 1,400 SF
#
RESTROOM ACCESSORIES SCHEDULE TAG CAB
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
C
LEASE LINE TO LEASE LINE
ADA RESTROOM 07
13
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
FIXTURE PLAN FIXTURE CONTRACTOR SPECIAL ITEMS: F.22 ?
FREE-STANDING FITTING ROOM (x2)
D.04 ?
DECORATIVE CEILING SLATS
F.23 ?
DISPLAY PLATFORM (x1)
? D.08
MIRRORED DOOR CUSTOM (x1); G.C. TO COORD. ROUGH OPENING W/ APPROVED SHOP DWGS
A-101
DATE 02/27/2019 03/04/2019
ARCHITECT
61' - 10" LEASE LINE TO LEASE LINE VESTIBULE
06
7' - 0" AFF
07
9' - 0" AFF
GYP. BOARD
9' - 0" AFF
GYP. CEILING
PT-01A
GYP. CEILING
23
27
27
TYP.
20
R-2
23 24 FL-1 25
TYP.
28
WD-02
B.O. EX'G SLAB
R-2 DC 25
P-3
9
S2
6
SD
F-2A
TYP.
F-2B
F-2A
17
F-2A
F-2B
EM-1
WP
CLG
CLG
F-2B F-2A F-2A
22
R-2
F-2B
F-2A F-2A
28
26
TYP.
TYP.
P-1 F-2B
22
CLG
F-2A F-2A
17
F-2B F-2A
F-2B F-2A
F-2A
FL-1
P-1 F-2A
F-2B F-2A
CLG
27
S1
33
TYP. R-2
R-2
R-2
CLG
23
OS
LS
4 A-501
T-01
R-2
EM-1
R-2
25
30
R-2
TYP.
STRUCTURAL ENGINEER
29
11' - 0" AFF
LS
TM
GYP. CEILING PT-01C
R-2
GB CLG
F-1 F-1 TR-1 F-1 F-1
MD CLG
TYP.
DC EXG-EM
01
12
S1 27
SM-1
16
F-2B
LICENSE # C-4550
DC
ENTRY
1
17 F-2A
EX'G MTL PANEL
18
EM-1
TR-2
8
TYP. ST
R-2
HS
17
F-2A F-2B F-2A
19
16
F-2B F-2A F-2A F-2B
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
8' - 2" V.I.F
EX-1
SD P-1
TYP.
CASE ENGINEERING, INC.
ENTRY VEST. SOFFIT
EX'G
13
P-1
CH-1 25
TC1
TR-2
2 R-2
P-1
27
16
F-2A
TR-2
TYP.
S2
17
21
P-1
J D
S
F-2B
32
TYP.
CLG
R-2
17
TC2
FL-1 P-3 6
MEP ENGINEER
10
R-2
S
CLG
A-502
1
P-2
R-2
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
4
3 A-502
S1
27
TYP.
TYP.
BLACK
5
S
32
19' - 9" V.I.F
CLG
11
ABV.
B.O. BEAMS
SD
SD
14
DC
B.O. TRACK
3 A-501
SD
ST
34
TYP.
03
OWNER'S REPRESENTATIVE
PT-02
EM-1
EX-2
SD
11' - 9" AFF
25
SD
23
CLG
13' - 3" AFF
TYP. TYP.
TYP. ST
WOOD BEAMS CASUAL/ TAILORED SHOP
TRACK LIGHTS
15
F-1 CLG
D D D
F-1
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
EXISTING LANDLORD CEILING BELOW
2
F-1
31
OSBORN
A-502
10
F-1
CLG CLG CLG
RETAIL TENANT
7
4
EXG-EX
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
PT-01C
3
26
A
LEASE LINE TO LEASE LINE
PT-01C
B
LIGHT COVE 11' - 5" AFF GYP. CEILING PT-01C
1
BOH
ADA FITTING ROOM
08
05
19' - 9" V.I.F
11
11
LOUNGE SHOP
WALL WASHER COVE
SALES CEILING
1
7' - 0" AFF
04
11' - 8" AFF
11' - 0" AFF
A-501
9' - 0" AFF
GYP. BOARD
11' - 0" AFF
GYP. CEILING
GYP. CEILING
B.O. EX'G SLAB
GYP. CEILING
PT-01A
GYP. CEILING
PT-01C
PT-01C
PT-02
PT-01C
ADA FR TRANS
1 NORTH
PT-01C
REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0"
REFLECTED CEILING PLAN SYMBOL / HATCH LEGEND HATCH / SYMBOL
SYMBOL
ROOM NAME 01 TYPE FINISH 0'-0" AFF SYMBOL
S CLG
WHITE
SUPPLY GRILLE
WHITE
REF. MEP
NEW PARTITION
EXHAUST FAN & GRILLE
WHITE
REF. MEP
EM-1
ROOM TAG
ACCESS PANEL
WHITE
X V.I.F.
SURFACE RECESSED EMERGENCY LIGHT
EX-1
1" TAPED-IN LINEAR SLOT
WHITE
REF. RCP
EX-2
LS HS DESCRIPTION FIRE ALARM SPEAKER/STROBE CEILING SUSPENDED PROVIDE STEM KIT; REF. MEP FOR REQ'D CANDELA RATINGS
MATCH ARAKAWA HANGING TRACK ADJ. NOTE FINISH REF. MEP AND APPROVED WHITE FIRE ALARM DWGS MOUNT AT VISIBLE HEIGHT
REF. RCP QTY 1
REF. MEP AND APPROVED FIRE ALARM DWGS MOUNT AT 96"AFF (MAX)
WHITE
2 EXG
ST CLG
FIRE ALARM STROBE CEILING MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS
REF. MEP AND APPROVED FIRE ALARM DWGS
WHITE
3
SD
SMOKE DETECTOR
REF. MEP DWGS
WHITE
5
SECURITY CAMERA, SURFACE MOUNTED
COORD. W/ SECURITY VENDOR
MATCH ADJ.
5
OS
OCCUPANCY SENSOR, WIRELESS CEILING MOUNTED
REF. MEP DWGS
WHITE
1
MD
MOTION DETECTOR WIRELESS
COORD. W/ SECURITY VENDOR
WHITE
1
GB
GLASS BREAK WIRELESS
COORD. W/ SECURITY VENDOR
WHITE
1
DC
DOOR CONTACT WIRELESS
COORD. W/ SECURITY VENDOR
MATCH 2 @ 2 ADJ. ENTRY 1 @ BOH
FLUSH CEILING SPEAKER
COORD. W/ A/V VENDOR
WHITE
2
20A GROUNDED DUPLEX CEILING OUTLET
REF. MEP DWGS
WHITE
2
J CLG
CEILING MOUNTED J-BOX
REF. MEP DWGS
MATCH ADJ.
11
D CLG
ABOVE CEILING DRIVER FOR STOREFRONT SIGNAGE/ LED TAPE LIGHT
COORD. W/ SIGNAGE VENDER
N/A
4
TC1
CLG TC2
CLG
WHITE
1
TRAFFIC COUNTER SECONDARY UNIT
COORD. W/ RETAILNEXT
WHITE
1
WIRELESS ACCESS POINT; PAINT TO MATCH ADJACENT FINISH
REF. APPROVED SPRINKLER DWGS REF. APPROVED SPRINKLER DWGS AS PER VENDOR DWGS (BANDWAVE)
WHITE U.N.O. WHITE U.N.O. N/A
W/V 100W
QUANTITY COMMENTS 1 CHANDELIER PROVIDED BY OWNERS (RETAIL TENANT); G.C. TO PROVIDE 2700K FROSTED LED LAMPS; VERIFY WITH RETAIL TENANT EXACT TYPE PRIOR TO PURCHASE
1. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT UNLESS OTHERWISE NOTED. 2. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SUBMIT PLANS FOR MODIFICATION OF THE FIRE SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE THE TENANT SPACE. SUBMIT SHOP DRAWINGS TO THE LANDLORD, OWNER, AND ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL.
EVENLIGHT-APERION
APR-25-LC-UI
WHITE
25W
5
G.C. TO PAINT TO MATCH ADJ. FINISH
3. ALL FINISHING AND PAINTING REQUIREMENTS SHALL BE AS PER THE FINISH SCHEDULE, INTERIOR ELEVATIONS, AND SPECIFICATIONS.
RECESSED CEILING MOUNTED EXIT SIGN AT SALES
CONTECH
REXA-SF-R-EM-C-P
WHITE
120/277 V
1
SINGLE FACE, RECESSED CEILING MOUNTED
4. ALL LIGHT FIXTURES, INCLUDING EXIT LIGHTS, EMERGENCY LIGHTS, ETC., SHALL BE FURNISHED BY OWNER AND INSTALLED BY THE CONTRACTOR, EXCEPT THE G.C. SHALL PROVIDE AND INSTALL THE LAMPS FOR THE SM-1 AND P-1 FIXTURES.
RECESSED WALL MOUNTED EXIT SIGN AT SALES
CONTECH
REXA-SF-R-EM-C-P
WHITE
120/277 V
1
SINGLE FACE, RECESSED WALL MOUNTED
5. THE CONTRACTOR SHALL USE A LASER LEVELING DEVICE FOR THE LEVELING OF ALL SOFFITS, CEILINGS, AND SUSPENDED GRIDS, TYPICAL. 6. THE ELECTRICAL CONTRACTOR IS TO VERIFY THAT THE EXISTING SERVICE IS ADEQUATE FOR THE DESIGN LOADS. IF NOT, NOTIFY THE ARCHITECT AND MEP ENGINEER IMMEDIATELY.
EXG
EXG
EXG
12W
1
EXTERIOR LED EM LIGHT
EXG-EX
WALL MOUNTED EXIT SIGN AT BOH
EXG
EXG
WHITE
120/277 V
1
EXISTING EXIT SIGN / EMERGENCY LIGHT COMBO TO REMAIN
WHITE
18W
8
GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY
9. ALL VENDORS TO BE COORD. BY G.C.
BLACK
18W
20
GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY
10. KEEP ALL NEW COMPONENTS MOUNTED AS HIGH AS POSSIBLE IN EXPOSED CEILING
BLACK
18W
13
GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY
11. ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT CONCEALED WHERE POSSIBLE.
F-2B
FL-1 P-1
12
9 1
MINI HORIZONTAL TRACK LIGHT FIXTURE MINI HORIZONTAL TRACK LIGHT FIXTURE MINI HORIZONTAL TRACK LIGHT FIXTURE
4' SUSPENDED LINEAR LED CEILING PENDANT LIGHT- 20"
AMERLUX-HORNET HIGH POWER AMERLUX-HORNET HIGH POWER AMERLUX-HORNET HIGH POWER
HORNET-HP-H-A14-18-LED-WTTJ1-120-SP-3000-97 HORNET-HP-H-A14-18-LED-BTTJ1-120-SP-3000-97 HORNET-HP-R/SR-FRAME-1-LE D-120 / HORNET-HP-R-TRIM-A14-2-18LED-BT-120-277-MFL-BT-3000-9 7 MERCURY LIGHTING LSA-4-4000-35K-HTA-U55-UNI
P-2
ALINEA LINEAR WALL SCONCE
AAMSCO
THE WESCO BLE-C-VDBW20-PC-975 W/ NARROW VENT SLOTS AND 8'-0" BLACK CORD LED100SYM-24K-BE
P-3
ALINEA LINEAR WALL SCONCE
AAMSCO
LED50SYM-24K-BE
BARN LIGHT ELECTRIC
P-4
ALINEA LINEAR WALL SCONCE
AAMSCO
LED50SYM-24K-PC
R-1
3"Ã&#x2DC; DIMMABLE LED RECESSED DOWNLIGHT SEMI-RECESSED LIGHT WITH 2-TRACK HEADS
SOLAIS LIGHTING
XR3NC-D-XM20-30K-1450-WH/ WH HORNET-HP-R/SR-NC-FRAMET-2-120-LE/TE / HORNET-HP-SR-NC-TRIM-T-2-1 8-WT-120-277-MFL-MFL-309-LE/ TE FM17080
R-2
SM-1 T-01
COORD. W/ RETAILNEXT
PENDANT SPRINKLER HEAD WP
3
TRAFFIC COUNTER PRIMARY UNIT
CONCEALED SPRINKLER HEAD
FINISH TBD
EXISTING LED LANDLORD EMERGENCY LIGHT
F-2A
BLACK
CLG
MODEL TBD
EXG-EM
F-1
COORD. W/ A/V VENDOR REF. ELEVATIONS FOR MOUNTING HEIGHT
WALL MOUNTED SPEAKER
MANUFACTURER LANGLEY STREET
REFLECTED CEILING PLAN KEY NOTES: 10
DECORATIVE CEILING BEAMS BY F.C.; G.C. TO PROVED IN-WALL BLOCKING AT PERIMETER AND COORD. DELIVERY AND INSTALL
11
CONTINUOUS 1" TAPED-IN LINEAR SLOT DIFFUSER; COORD. W/ MEP DWGS, TYP.
12
HS - MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.
13
EXIT SIGNAGE: RECESSED CEILING MOUNTED; COORD. W/ ELEVATIONS.
14
EXIT SIGNAGE EM LIGHT COMBO EXISTING TO REMAIN: SURFACE WALL MOUNTED; COORD. W/ ELEVS.
15
SURFACE MOUNTED TRACK LIGHTING IN LIGHT COVE; FINISH WHITE; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE; REF. A-501 CONSTRUCTION DETAIL; COORD. W/ MEP DWGS.
16
SUSPENDED TRACK LIGHTING ABOVE DECORATIVE BEAMS; FINISH BLACK; COORD. W/ MEP DWGS.
17
NEW SUSPENDED PENDANTS CORD HUNG, MOUNT B.O. PENDANT @ 8'-8", VERIFY IN FIELD; G.C. TO PROVIDE FROSTED 60W INCANDESCENT LAMPS; 2700K
18
NEW RETAIL TENANT LOGO: 15"H COLORED LED ILLUMINATED NEON LOOK LETTERS. EACH LETTER TO HAVE INDIVIDUAL WHITE METAL BACKS. EACH LETTER TO BE ENCLOSED IN INDIVIDUAL, NON REFLECTIVE CLEAR ACRYLIC BOXES. G.C. TO SUSPEND EACH SIGN BOX FROM INTERIOR CEILING AT TWO POINTS WITH LETTERS CENTERED IN THE WINDOW. G.C. TO PROVIDE CONCEALED J-BOX AND ACCESS AT INTERIOR. COORDINATE INSTALL AND LOCATION WITH SIGNAGE VENDOR. SIGNAGE TO BE CONTROLLED BY 24/7 PROGRAMMABLE TIME CLOCK. SIGNAGE FILED UNDER SEPARATE PERMIT
19
G.C. TO PROVIDE 12" x 12" ACCESS PANEL (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR SIGNAGE DRIVER ACCESS, COORD. EXACT LOCATION W/ MEP DWGS AND SIGNAGE VENDOR.
20
EXG. EXHAUST FAN AND GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR
21
PAINT-GRADE INTERNALLY INSULATED SPIRAL STEEL DUCTING AT EXPOSED SALES AREAS; G.C. TO PAINT TO MATCH ADJACENT CEILING COLOR; COORD. W/ MEP DWGS. NEW SUPPLY GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR.
7. ENSURE THAT ALL EQUIPMENT INCLUDES / BARES UL LABELS.
FIRE ALARM SPEAKER/STROBE WALL MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS
S2 CLG
DESCRIPTION CHANDELIER
RETURN GRILLE
S
S1
TAG CH-1
FINISH
EXISTING PARTITION TO REMAIN
QTY REF. MEP
SYMBOL
DESCRIPTION
DESCRIPTION
REFLECTED CEILING PLAN GENERAL NOTES:
LIGHTING SCHEDULE
SURFACE MOUNTED GLOBE LIGHT LED TAPE LIGHT
AMERLUX-HORNET HIGH POWER
SHADES OF LIGHT LEVITON
TR-1
SURFACE MOUNTED LIGHT TRACK
CONTECH
TAPE LIGHT: (3) TLT-12V-3-30K-16CR; 60W DRIVER: (3) TLP12VHW60-ENC; CHANNEL: (5) TLACA6 LT-P
TR-2
SUSPENDED LIGHT TRACK
CONTECH
LT-B
8. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTS; ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIELD FIRE INSPECTOR AT THE TIME OF THE FINAL BUILDING INSPECTION.
12. ACCESS PANELS IN CEILING MUST BE LOCATED TO PROVIDE ACCESS TO LANDLORD'S MECHANICAL EQUIPMENT PER LOCAL GENERAL GROWTH AUTHORITY.
WHITE
34W 60W
3 6
SUSPENDED FROM CEILING/DECK ABOVE @ 12'-0" AFF
GALVANIZED
B.O. PENDANT MOUNTED AT 8'-8" AFF; VERIFY IN FIELD WITH 60W FROSTED SOFT WHITE (2700K) INCANDESENT LAMPS
BLACK
11W
1
MTD. @ 7-10" AFF CENTERED ABOVE MIRROR
BLACK
7W
2
MTD. @ 7'-2" AFF CENTERED ON WALL
13. SPRINKLER HEADS AT GYPSUM BOARD CEILING MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING TILES WHERE APPLICABLE
REFLECTED CEILING PLAN GENERAL NOTES:
POLISHED CHROME WHITE
11W
1
17W
2
WHITE
36W
15
OLD BRONZE LED
60W 108W (3 x 36W / 12V)
1 1 24' - 10" VIF
MTD. @ 6-8" AFF CENTERED ABOVE MIRROR
1
LEASE LINE
2
EXISTING AHU BY LANDLORD ABOVE; G.C. TO SERVICE AND CONFRIM FUNCTIONS PROPERLY; COORD. W/ MEP DWGS.
3
SEMI-RECESSED CEILING MOUNTED
SURFACE MOUNTED; SOCKET FINISH: OLD BRONZE; CANOPY: OLD BRONZE; G.C. TO PROVIDE 60W E26 (MEDIUM BASE) SOFT WHITE (2700K) INCANDESCENT LAMPS REF. TO ARCHITECTURAL CEILING DETAILS FOR MOUNTING IN WASHER COVE; LENGTH: 24'-10" VIF CUT LED TAPE IN FEILD TO INSTALL IN 3 EQUAL LENGTHS
WHITE
120 V
REF PLANS 1 SURFACE MOUNTED TRACK; G.C. TO CUT LENGTHS PER RCP.
BLACK
120 V
3 TRACK SUSPENDED WITH AIRCRAFT CABLE AND HOLLOW STEM REF PLANS KIT AT POWER FEED LOCATIONS ONLY; G.C. TO CUT LENGTHS PER RCP.
NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN A.F.F. AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT/BRACING AS REQ'D ; COORD. WITH MEP DRAWINGS.
23
NEW SUPPLY GRILLE; COORD. W/MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR.
PROJECT NO.: 218259
24
DEMOLISH EXISTING ACT CEILING AND 2x4 LIGHT; PRIOR TO INSTALL OF NEW GYP. BOARD CEILING; (DEDUCT ALT: EXISTING ACT CEILING AND LIGHT TO REMAIN; CONFIRM WITH TENANT PRIOR TO DEMO)
DATE: 02/27/2019
25
NEW GWB CEILING @ ALL SALES / FITTING ROOM/ VESTIBULE LOCATIONS, TYP.
CHECKED BY: JSP
26
AREA OPEN TO EXISTING DECK ABOVE DECORATIVE TRELLIS AND @ ALL B.O.H. LOCATIONS, TYP; G.C. TO PAINT EXPOSED DECK PT-02; G.C TO ENSURE ASSEMBLY MEET 50 51C AND 50 11C
27
CONCEALED SPRINKLER HEAD W/ WHITE COVER; COORD. W/ MEP AND APPROVED SPRINKLER DWGS.
28
UPRIGHT SPRINKLER HEAD; COORD. W/ MEP AND APPROVED SPRINKLER DWGS.
5
NEW ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE MIRROR @ 7'-10" AFF; REF. ELEVATIONS; FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH.
29
EXISTING LANDLORD EM LIGHT TO REMAIN AT EXTERIOR SOFFIT BELOW
30
NEW LED TAPE LIGHT ABOVE IN COVE; CUT AND SPLICE LED STRIPS IN 3 EQUAL LENGTHS
6
NEW ALINEA LINEAR LIGHT FIXTURE; CENTER ON FITTING ROOM WALL @ 7'-2" AFF; REF. ELEVATIONS; FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH.
31
7
NEW ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE RESTROOM MIRROR @ 6'-8" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN POLISHED CHROME; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH
G.C. TO PROVIDE 12" x 12" ACCESS PANEL (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR LED TAPE LIGHT ACCESS ACCESS TO EXISTING LANDLORD BUILDING PIPES. G.C. TO VERIFY ON SITE REQUIRED SIZE AND CONFIRM LOCATION WITH RETAIL TENANT PRIOR TO INSTALL
32
NEW DRAPERY PANEL INSTALLED ON TAPED-IN RECESSED CURTAIN TRACK AT ADA FITTING ROOM OPENING; B.O. OPENING AT 7'-0" AFF; FINISH TRACK WHITE; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS
EXISTING DECK ABOVE IS 3 HOUR-RATED CONCRETE SLAB; IF FIRE PROTECTION IS DAMAGED, G.C SHALL RESTORE IT TO ITS ORIGINAL CONDITIONS AND FIRE PROTECTION RATING.
33
NEW DRAPERY PANEL INSTALLED ON RODS AND RINGS AT FREE-STANDING FITTING ROOMS; RODS AND RINGS TO BE INSTALLED DURING ASSEMBLY OF FREE-STANDING FITTING ROOM FIXTURES (F.22); G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS
G.C. TO PROVIDE 12" x 12" ACCESS PANEL (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR ACCESS TO EXISTING LANDLORD BUILDING PIPES. G.C. TO VERIFY ON SITE REQUIRED SIZE AND CONFIRM LOCATION WITH RETAIL TENANT PRIOR TO INSTALL
34
EXIT SIGNAGE RECESSED WALL MOUNTED
9
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
NEW RETURN GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR.
G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; COORD. W/ MEP AND STRUCT DWGS
8
STAMP
22
4
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
VEST. TRANS
20' - 10"
C
RESTROOM
DRAWN BY: RA, NK AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
REFLECTED CEILING PLAN
A-102
ARCHITECT
61' - 9 11/16" LEASE LINE TO LEASE LINE
C
B 44
18
GFI @ 46" AFF
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
W
6
OS
OWNER'S REPRESENTATIVE
35
CLG
9
SD
T
6
SD
S2
4
W
D D OS
9' - 6"
F
TM
F
CLG
17
29
S 35
CLG
32
29
21
S2
WP
CLG
CLG
CLG
J CLG
J
J
CLG
31
CLG
31
V
CP AV NM CG
14
@ 15" AFF
27
DC
CLG
LICENSE # C-4550
J CLG
15
13
@ 93" AFF @ 93" AFF @ 93" AFF
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
31
12
@ 93" AFF
CASE ENGINEERING, INC. DC
TC1
22
31
@ 15" AFF
W
KP
M D D D
40
TC2
5
MEP ENGINEER
31 J
38
36
40
2' - 6"
10
CLG ABV.
34
19
39 S
16
J D
S
@ 14'-0" AFF
25
W
10
37
S1 28
DC
AS
LEASELINE TO LEASELINE
27' - 4"
1
3
SD
26
10
CLG
35
J
J
CLG
CLG
31
SD 31
J CLG
35
GB
31
24
17 J ST
33
@ 14'-0" AFF
MD TS CLG
@ 14'-0" AFF
S1
CLG
S1 28
CLG
31
D D D
@ 24" AFF
CLG CLGCLG
11
J
9
CLG
9
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
10
CLG
10
25
OSBORN
28
OS
9
TM
23
30 7
STRUCTURAL ENGINEER
20
CLG
8
1
CLG
31
GFI
25
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
EQ
10
ST
43 2
EQ
20' - 10"
41
33
SD
ST
35
9
1
10
25
NORTH
1
POWER & SIGNAL PLAN SCALE: 1/4" = 1'-0"
POWER & SIGNAL PLAN SYMBOL / HATCH LEGEND SYMBOL / HATCH
POWER & SIGNAL GENERAL NOTES:
DESCRIPTION
SYMBOL
EXISTING PARTITION TO REMAIN GFI
NEW PARTITION ROOM NAME 01 SYMBOL
ROOM TAG
S CLG
DESCRIPTION FIRE ALARM SPEAKER/STROBE CEILING SUSPENDED PROVIDE STEM KIT; REF. MEP FOR REQ'D CANDELA RATINGS
NOTE REF. MEP AND APPROVED FIRE ALARM DWGS MOUNT AT VISIBLE HEIGHT
FINISH
QTY
WHITE
1
S
FIRE ALARM SPEAKER/STROBE WALL MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS
REF. MEP AND APPROVED FIRE ALARM DWGS MOUNT AT 96"AFF (MAX)
ST CLG
FIRE ALARM STROBE CEILING MOUNTED; REF. MEP FOR REQ'D CANDELA RATINGS
REF. MEP AND APPROVED FIRE ALARM DWGS
SD
SMOKE DETECTOR
REF. MEP DWGS
WHITE
SECURITY CAMERA, SURFACE MOUNTED
COORD. W/ SECURITY VENDOR
MATCH ADJ.
WHITE
WHITE
2 EXG
5
CLG
J CLG
OS
OCCUPANCY SENSOR, WIRELESS CEILING MOUNTED
REF. MEP DWGS
WHITE
1
MD
MOTION DETECTOR WIRELESS
COORD. W/ SECURITY VENDOR
WHITE
1
OS
GB
GLASS BREAK WIRELESS
COORD. W/ SECURITY VENDOR
WHITE
1
M
DC
DOOR CONTACT WIRELESS
COORD. W/ SECURITY VENDOR
KP
CP
WP
SECURITY ALARM KEYPAD SECURITY ALARM CONTROL PANEL WIRELESS ACCESS POINT
COORD. W/ SECURITY VENDOR, MOUNT AT 48" MAX COORD. W/ SECURITY VENDOR COORD. W/ VENDOR
MATCH 2 @ ADJ. ENTRY 1 @ BOH WHITE
1 1
WHITE
1
AUDIO / VISUAL CONTROL PANEL
COORD. W/ A/V VENDOR
WHITE
1
V
VOLUME CONTROLS
COORD. W/ A/V VENDOR MOUNT AT 48" MAX
WHITE
1
WALL MOUNTED SPEAKER
COORD. W/ A/V VENDOR REF. ELEVATIONS FOR MOUNTING HEIGHT
BLACK
COORD. W/ A/V VENDOR
WHITE
S2 CLG T TS TM
FLUSH CEILING SPEAKER
D CLG
CLG TC2
AV
S1
D
TC1
WHITE
NOTE
FINISH
QTY
WALL MOUNTED 20A GROUNDED DUPLEX RECEPTACLE
REF. MEP DWGS MOUNT AT 18" U.N.O.
WHITE
5
WALL MOUNTED 20A GROUNDED DUPLEX RECEPTACLE W/ GROUND FAULT INTERRUPTER
REF. MEP DWGS MOUNT AT 18" U.N.O.
WHITE
2
WALL MOUNTED 20A GROUNDED DEDICATED DUPLEX RECEPTACLE
REF. MEP DWGS MOUNT AT 18" U.N.O.
DEDICATED 4-GANG FLUSH FLOOR BOX: HUBBLE CFB4G30RCR W/ 8"Ø BLACK FLUSH COVER PLATE CFBS1R8CVRBLK; PROVIDE (3) GROUNDED 20A DUPLEX RECEPTACLES AND (1) TELE/DATA OUTLET
3
5
DESCRIPTION
CLG
REF. MEP DWGS INSTALL COVER FLUSH WITH FINISH FLOOR
WHITE
6
1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED ON THIS PLAN AND ELEVATIONS. COORDINATED W/ THE FIXTURE PLAN ANY DISCREPANCIES REGARDING THE LOCATION(S) SHOWN HERE AND THE FIELD VERIFIED OR EXISTING CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT PRIOR TO COMMENCING THE WORK AFFECTED. 2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE ELECTRICAL CODE, NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE COMPANY, AND ALL AUTHORITIES HAVING JURISDICTION. 3. U.N.O. , ALL COVERPLATES AND DEVICES ( ELECTRICAL, SWITCHES, RECEPTACLES, COVER PLATES), SHALL HAVE FINISH COLOR TO MATCH ADJACENT FINISH COLOR.
BLACK
1
TRENCHING REQUIRED
4. SHALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH (2) PULL STRINGS BACK TO THE TELEPHONE EQUIPMENT. 5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALL CHASES IN THE FLOOR, WALLS, AND CEILING SURFACES AND MATERIALS AS REQUIRED.
POWER & SIGNAL PLAN KEY NOTES: 1
LEASE LINE
27
VOLUME CONTROL; FINISH WHITE MOUNTED @ 48" AFF MAX. ONTO TELE/DATA BOARD; REF. ELEVATIONS FOR MOUNTING LOCATION; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK) RECESSED CEILING MOUNTED SPEAKER; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH WHITE
2
EXISTING ELECTRICAL PANEL TO REMAIN; G.C. TO RE-CIRCUIT AS REQUIRED; COORD. W/ MEP DWGS
3
MULTI-CHANNEL 24/7 PROGRAMMABLE TIME CLOCK; COORD. W/ MEP DWGS.
4
SWITCH BANK; FINISH FOR ALL SWITCHES TO BE WHITE; ALL SWITCHES MTD. @ 48" AFF MAX, TYP.; COORD. W/ MEP DWGS
28
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX, MOUNTED; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; REF. ELEVATIONS FOR MOUNTING LOCATIONS
5
MASTER OVERRIDE SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.
6
OCCUPANCY SENSOR COMBINATION SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.
29
RECESSED CEILING MOUNTED SPEAKER; G.C. TO PROVIDE CONDUIT& PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH WHITE.
7
CEILING MOUNTED OCCUPANCY SENSOR; FINISH WHITE
30
ABOVE CEILING DRIVER FOR LED TAPE LIGHTING; COORD. W/ MEP DWGS
8
WALL MOUNTED G.F.I. DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 46" AFF U.N.O.
31
SUSPENDED J-BOX FOR TRACK LIGHTING, LED STRIP LIGHTING AND PENDANTS; COORD. W/ MEP DWGS
9
WALL MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O.
32
CEILING MOUNTED FIRE ALARM SPEAKER/ STROBE; FINISH WHITE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS
10
WALL MOUNTED DEDICATED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O. 33
CEILING MOUNTED FIRE ALARM STROBE; FINISH WHITE; COORD. W/ MEP DWGS &APPROVED FIRE ALARM DWGS
20A GROUNDED DUPLEX CEILING OUTLET
REF. MEP DWGS
WHITE
1
6. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED SHALL BE PATCHED FLUSH WITH ADJACENT WALL SURFACES.
WALL MOUNTED DATA RECEPTACLE
REF. MEP DWGS
WHITE
2
7. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL NOT EXCEED 6".
11
CEILING MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" MAX. FROM GLAZING TYP.
WALL MOUNTED TELE/DATA RECEPTACLE
REF. MEP DWGS
WHITE
1
8. PROVIDE A MINIMUM OF 10% SPACE CIRCUITS IN EXISTING ELECTRICAL PANEL(S) PROVIDE BREAKER LOCKOUTS FOR VAV UNITS AND SEPARATE CIRCUIT OUTLINES AT TELEPHONE EQUIPMENT.
12
MOUNT (2) QUAD RECEPTACLES AND (1) TELE/DATA OUTLET @ 93" AFF ABOVE TELE/DATA BOARD, AND (1) QUAD RECEPTACLE @ 15" MIN. AFF BELOW TELE/DATA BOARD. REF. ELEVATIONS
34
EXISTING FIRE-ALARM SPEAKER-STROBE; G.C. TO CONFIRM THAT FINISH IS WHITE AND IF RED REPLACE WITH EQUIVALENT WHITE DEVICE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS
CEILING MOUNTED J-BOX
REF. MEP DWGS
MATCH ADJ.
11 X
13
PROVIDE (1) LOW VOLTAGE STUB UP @ 15" MIN. AFF BELOW TELE/DATA BOARD AND (1) LOW VOLTAGE STUB UP @ 93" AFF ABOVE DESK. REF. ELEVATIONS
35
CEILING / DECK MOUNTED SMOKE DETECTOR; FINISH WHITE
WHIP CONNECTION
REF. MEP DWGS
MATCH ADJ.
9. ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT CONCEALED WHERE POSSIBLE.
4
36
14
ABOVE CEILING DRIVER FOR STOREFRONT SIGNAGE; COORD. W/ MEP DWGS & SIGNAGE VENDOR; G.C. TO COORD. AND SUPERVISE INSTALL. SIGNAGE FILED UNDER SEPARATE PERMIT.
SWITCH
REF. MEP DWGS
WHITE
2
RUN ALL AV/DATA AND LOW VOLTAGE VENDORS TO B.O.H.; G.C. TO PROVIDE CONDUIT AND PULL STRING FOR ALL. DEDICATED 4-GANG FLUSH FLOOR BOX UNDER BAR (F.16): : HUBBLE CFB4G30RCR W/ 8"Ø BLACK FLUSH COVER PLATE CFBS1R8CVRBLK; G.C. TO TRENCH SLAB AS REQ'D, REF. A-104 FINISH PLAN
37
15
ABOVE CEILING J-BOX FOR STOREFRONT SIGNAGE; COORD. W/ MEP DWGS & SIGNAGE VENDOR; G.C. TO COORD. AND SUPERVISE INSTALL. SIGNAGE FILED UNDER SEPARATE PERMIT. CEILING MOUNTED WIRELESS ACCESS POINT; G.C. TO PROVIDE BACK-BOX CONDUIT AND PULLING
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE MIRROR @ 7'-10" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH
38
16
39
EXISTING FIRE-ALARM SPEAKER-STROBE TO REMAIN; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS
17
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; CENTER ON FITTING ROOM WALL @ 7'-2" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN MATTE BLACK; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH
40
EXISTING FIRE-ALARM PULL STATION TO REMAIN
41
G.C. TO PROVIDE NEW DISCONNECT SWITCH; COORD. W/ MEP DWGS.
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; CENTER ABOVE RESTROOM MIRROR @ 6'-8" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN POLISHED CHROME; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH
42
G.C. TO SUSPEND EXISTING TRANSFORMER ABOVE; COORD. W/ ELECTRICAL AND STRUCTURAL DWGS
43
G.C. TO RELOCATE EXISTING DISCONNECT SWITCH NEXT TO ELECTRICAL PANEL; COORD. W/ MEP DWGS
44
WALL MOUNTED G.F.I. DUPLEX RECEPTACLE AT RESTROOM; FINISH WHITE; MTD @ 46" AFF U.N.O.
OCCUPANCY SENSOR/SWITCH
REF. MEP DWGS
WHITE
2
MASTER OVERRIDE SWITCH
REF. MEP DWGS
WHITE
1
DIMMER SWITCH
REF. MEP DWGS
WHITE
5
ABOVE CEILING DRIVER FOR STOREFRONT SIGNAGE/LED TAPE
COORD. W/ SIGNAGE VENDER
N/A
10. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM LOCATION AND REQUIREMENTS.
4
TRAFFIC COUNTER PRIMARY UNIT
COORD. W/ RETAILNEXT
WHITE
1
TRAFFIC COUNTER SECONDARY UNIT
COORD. W/ RETAILNEXT
WHITE
1
18
19
PROGRAMMABLE THERMOSTAT, MOUNTED AT 48"AFF MAX; FINISH WHITE; COORD. W/ MEP DWGS.
20
FLUSH WHITE BUTTON TYPE TEMPERATURE SENSOR MOUNTED AT 48"AFF MAX; COORD. W/ MEP DWGS.
21
SHOPPER TRACK TRAFFIC COUNTER; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE
22
SHOPPER TRACK TRAFFIC COUNTER; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE
23
WIRELESS MOTION DETECTOR; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)
24
WIRELESS GLASS BREAK; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)
25
WALL MOUNTED CAMERA; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ SECURITY VENDOR (ADT); G.C. TO PAINT HOUSING TO MATCH ADJ. SURFACE; REF. ELEVATIONS FOR MOUNTING LOCATIONS
26
SECURITY KEYPAD; FINISH WHITE; MTD. @ 48" AFF MAX; G.C. TO COORD. INSTALL W/ SECURITY VENDOR (ADT)
3 2
THERMOSTAT
REF. MEP DWGS MOUNT AT 48" MAX
WHITE
TEMPERATURE SENSOR FLUSH BUTTON TYPE
REF. MEP DWGS MOUNT AT 48" MAX
WHITE
1
MULTICHANNEL TIME CLOCK 24/7 PROGRAMMABLE
REF. MEP DWGS
WHITE
1
1
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
42
RETAIL TENANT
33
LEASE LINE TO LEASE LINE
25
A
STAMP
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
POWER & SIGNAL PLAN
A-103
ARCHITECT
61' - 10"
PW-01
C-02
7 10
7
TYP.
1
2
2
2
2' - 6"
MEP ENGINEER
3' - 0"
CPT-02
14
9' - 6"
26' - 7 5/8"
LEASELINE TO LEASELINE
27' - 4" BOH 08 WALL PT-01A/ PT-02 12 BASE B-02 FLOOR C-04
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
2
14 TYP.
13
TYP.
17
2
OWNER'S REPRESENTATIVE
C-04 8
2' - 5 1/4"
TYP. 10' - 0" SLAB LEAVE-OUT
VIF
VIF
TYP.
5
6 C-02
16
A
C-02
7
12
CASE ENGINEERING, INC.
4
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
TYP.
7 13
2' - 2 3/8" 2
8' - 0"
EQ.
TYP.
2' - 2 3/8" EQ.
2 3
6' - 0"
2 C-02
CPT-01
LICENSE # C-4550
ENTRY 01 WALL PT-01A BASE B-01/PT-01B FLOOR C-02 / CPT-02B
STRUCTURAL ENGINEER
2
2
DISPLAY WINDOW 02 WALL PT-01A BASE N/A FLOOR C-02
LEASE LINE TO LEASE LINE
3
CASUAL/ TAILORED SHOP 03 WALL PT-01A/PT-02 BASE B-01/PT-01B FLOOR C-02
LOUNGE 04 WALL PT-01A BASE B-01/PT-01B FLOOR C-02
2
2
C-02
15
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
1
3 3
A
20' - 10"
10
B
2' - 3 1/4"
11
LEASE LINE TO LEASE LINE
5' - 0"
C
3" MIN.
VESTIBULE 06 WALL PT-01A BASE B-01/PT-01B FLOOR C-02
ADA RESTROOM 07 WALL PT-01D BASE B-01/PT-01E FLOOR C-02
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
1
TYP.
2
2
1' - 6"
8 3/8"
7 3
9
2
3
1
ADA FITTING ROOM 05 WALL PT-01A BASE B-01/PT-01B FLOOR C-02
1
NORTH
FLOOR & WALL FINISH PLAN SCALE: 1/4" = 1'-0"
CONSTRUCTION PLAN SYMBOL / HATCH
FINISH SCHEDULE
SYMBOL / HATCH
FINISH CODE B-01 B-02 C-02
DESCRIPTION
EXISTING PARTITION TO REMAIN
NEW PARTITION
CONCRETE FLOOR
ROOM NAME 01 WALL WALL FINISH BASE BASE FINISH FLOOR FLOOR FINISH
FINISH ROOM TAG
C-04
FLOOR AND WALL FINISH PLAN KEY NOTES:
DESCRIPTION PAINTED WOOD WALL BASE RUBBER WALL BASE EXISTING CONCRETE WITH CUSTOM FINISH
LOCATION SALES BOH SALES/ VESTIBULE/ RESTROOM
MANUFACTURER G.C. JOHNSONITE UNCONVENTIONAL FLOORING
EXISTING CONCRETE WITH CUSTOM FINISH
BOH
UNCONVENTIONAL FLOORING
LOUNGE ENTRY FITTING ROOMS MIRRORS FIXTURES FIXTURES
TBD MATS INC. MAHARAM G.C F.C. G.C. SIGN VENDOR
CPT-01 CPT-02 FB-01 GL-01 MT-01 MT-02 MT-04
REMOVABLE AREA RUG WALK-OFF MAT FABRIC - CURTAIN MIRROR METAL-MATTE BLACK POWDER-COATED METAL - BLACK POWDER-COATED METAL - WHITE
PT-01A PT-01B PT-01C PT-01D
INTERIOR PAINT INTERIOR PAINT INTERIOR PAINT INTERIOR PAINT
WALL DOOR/TRIMS CEILING RESTROOM WALL
BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE
PT-01E
INTERIOR PAINT
RESTROOM DOOR/ TRIM
BENJAMIN MOORE
PT-02
INTERIOR PAINT
BENJAMIN MOORE
PW-01 WD-01 WD-02 WD-03
WATERPROOF POLYWALL WHITE OAK HICKORY WOOD WALNUT WOOD
CEILING @ SALES AREA ABOVE DECORATIVE SLATS MOP SINK FIXTURES FIXTURES FIXTURES MILLWORK
FIXTURES
FINISHES PAINT GRADE POPLAR; REF. PLAN FOR PAINT FINISH TRADITIONAL WALL BASE; MODEL# JODC2824X; FINISH 282 VAPORIZE EXISTING CONCRETE FLOOR TO REMAIN G.C. TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR: CHARCOAL; FINISH: SEMI-GLOSS EXISTING CONCRETE FLOOR TO REMAIN G.C. TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM POLISH AND SEAL; FINISH: CLEAR TBD COCOA MAT - CHARCOAL GRAY CANVAS BY KVADRAT 466185 CLEAR REFLECTIVE MIRROR, TEMPERED BLACKENED METAL TO MATCH CHEMETAL 908 MATTE BLACK POWDER COAT TO MATCH CHEMETAL 908 POWDER COAT TO MATCH PT-01 BENJAMIN MOORE SIMPLY WHITE OC-117 SIMPLY WHITE OC-117; FINISH: EGGSHELL SIMPLY WHITE OC-117; FINISH: SEMI-GLOSS SIMPLY WHITE OC-117; FINSIH: FLAT COROTECH PRE-CATALYZED WATERBRONE EPOXY - V342; COLOR: SIMPLY WHITE OC-117; FINISH: EGGSHELL; LOW VOC COROTECH ACRYLIC DTM ENAMEL - V331; COLOR: SIMPLY WHITE OC-117; FINISH: SEMI-GLOSS; LOW VOC WROUGHT IRON 2124-10; FINISH: FLAT
DIMENSIONS 3/4"D x 4"H 4"H --
-96"W x 72"L 36'W x 72"L REF. PLANS REF. ELEV ---
REMARKS/NOTES REFER TO A-600 FOR DETAILS AND TRIM PROFILES REFER TO A-600 FOR DETAILS GRIND, STAIN, SEAL AND POLISH W/ 16 GRIT DIAMOND TO 1500 GRIT; G.C. TO TEST IN B.O.H. AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT
GRIND 80 GRIT DIAMOND FOLLOWED BY GRIND W/ 100 GRIT TRANSITIONALS; APPLY (2) COATS OF TENNANT ECO-ITS; FINISH: SATIN CLEAR NOT INSET; COORDINATE WITH FLOOR FINISH PLAN; BY OWNER (RETAIL TENANT) INSET; COORDINATE WITH FLOOR FINISH PLAN FURNISHED BY OWNER (RETAIL TENANT); G.C. TO COORD. INSTALL W/ BRAD JOBE; REF. A-500 FOR DETAILS G.C. TO PROVIDE FRAMES FURNISHED BY F.C.; REF. A-101; G.C TO VERIFY DIMS IN FIELD AND SECURE TO FRAMES W/ MASTIC G.C. TO PROVIDE SAMPLE FOR APPROVAL SIGN VENDOR TO PROVIDE SAMPLE FOR APPROVAL
1
LEASE LINE
2
G.C. TO SUPPLY AND INSTALL NEW PAINTED WOOD WALL BASE, B-01; REF. A-600 FOR DETAILS
3
G.C. TO SUPPLY AND INSTALL NEW RUBBER WALL BASE, B-02; REF. A-600 FOR DETAILS
4
EXISTING ADA COMPLIANT THRESHOLD AT STOREFRONT ENTRY TO REMAIN; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)
5
G.C. TO TRENCH SLAB TO RUN POWER UNDERNEATH TO FLUSH MOUNTED FLOOR BOX; REF. A-103 POWER & SIGNAL PLAN
6
G.C. TO PROVIDE NEW REMOVABLE WALK-OFF MAT
7
EXISTING CONCRETE FLOOR TO REMAIN, G.C TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR BY RETAIL TENANT REQUIRED VENDOR; CHARCOAL; FINISH; SEMIGLOSS; REF. A-600
8
EXISTING CONCRETE FLOOR TO REMAIN; G.C. TO PREP FLOOR PER VENDOR RECCOMENDATION FOR NEW GRIND AND SEAL BY RETAIL TENANT VENDOR; FINISH: CLEAR
9
NEW REMOVABLE AREA RUG BY OWNER (RETAIL TENANT); NO TRIP HAZARD AT PERIMETER OF AREA RUG. CARPET TO COMPLY WITH ADA LEVEL CHANGE REQUIREMENTS (ADA 2010 SECTION 303) AND SHALL NOT EXCEED 1/4" THK. OR 1/2" THK IF EDGE IS BEVELED AT A SLOPE NOT STEEPER THAN 1:2.
STAMP
-----
G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL
--
LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL
--
G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL; PAINT LINE AT BOH: 12'-0" AFF. G.C. TO PAINT ALL WALLS ABOVE THIS LINE PT-02.
10
G.C. TO USE MOISTURE-RESISTANT TYPE "X" GWB AT THE WALLS IN WET AREAS, INCLUDING THE RESTROOM, TYP.
G.C. TO CUT DOWN AS REQUIRED, REF. PLANS & ELEVS FOR SIZE FINISH TO MATCH CONTROL SAMPLE FINISH TO MATCH CONTROL SAMPLE FINISH TO MATCH CONTROL SAMPLE
11
NEW PLASTEX PLOYWALL WATERPROOF PANEL UP TO 48" AFF AT THE MOP-SINK SURROUND, REF. ELEVATIONS.
12
G.C. TO ESTABLISH A PAINT LINE @ 12'-0" AFF AT B.O.H. PAINT WALLS PT-01A BELOW 12'-0" AFF AND PT-02 ABOVE 12'-0" AFF
13
G.C. TO ESTABLISH A PAINT LINE @ 11'-9" AFF AT SALES AREA WALLS. PAINT WALLS PT-01A BELOW 11'-9" AND PT-02" ABOVE 11'-9"
14
NEW DOOR AND FRAME; PAINT PT-01B U.N.O., REF. ELEVATIONS
PROJECT NO.: 218259
3. ALL CONCRETE FINISHES TO FOLLOW DESCRIPTION PROVIDED IN FINISH SCHEDULE; SAMPLE TO BE PROVIDED IN FINISH SCHEDULE; G.C. TO TEST FINISH IN BOH AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT.
15
LANDLORD G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT ADD-ALT IF NOT PROVIDED BY LANDLORD, G.C. TO PROVIDE IN-FILL; REF. LANDLORD DWGS. FOR REQUIRED SLAB INFILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS
DATE: 02/27/2019
4. INSTALLATION OF FINISHES AND FIXTURES TO BE COORDINATED BETWEEN G.C., F.C., AND ALL VENDORS, TYP.
16
EXISTING LANDLORD SIDEWALK TO REMAIN
17
EXISTING DOOR AND FRAME; G.C. TO PAINT PT-01E U.N.O., REF. ELEVATIONS
X-01
X
FINISH TAG
THRESHOLD TAG WALL BASE LOCATION
FINISH PLAN GENERAL NOTES: 1. ALL FINISHING AND PAINTING REQUIREMENTS BE AS PER FINISH SCHEDULE, ELEVATIONS AND SPECIFICATIONS. 2. ALL INTERIOR GWB PAINT TO BE SPRAY APPLIED AND BACKROLL FINISHED. SAMPLE TO BE PROVIDED TO ARCHITECT FOR APPROVAL. G.C. AND F.C. TO COORDINATE AND MATCH PAINTED FINISHES.
5. G.C. TO SUBMIT SAMPLES OF ALL FINISHES FOR FINAL APPROVAL PRIOR TO ORDERING OF MATERIALS OR INSTALLATION.
PLAS-TEX F.C. F.C. F.C.
POLYWALL MODEL# PTC0043M; FINISH WHITE NATURAL OAK WOOD, PLAIN SAWN; FINISH: CLEAR MATTE NATURAL HICKORY WOOD; FINISH: CLEAR MATTE NATURAL WALNUT WOOD; FINISH: CLEAR MATTE
48"H ----
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
RETAIL TENANT
10
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
6. ALL MATERIALS AND FINISHES MUST BE FIRE-RATED AND HAVE FLAME RESISTANCE COMPLYING WITH LOCAL & STATE CODES. 7. ALL SURFACES AT TRANSITIONS BETWEEN DIFFERENT OR EXISTING NEW MATERIALS TO BE FLUSH AND/OR A.D.A. COMPLIANT 8. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.
FLOOR & WALL FINISH PLAN
A-104
ARCHITECT
PAINT-GRADE INTERNALLY INSULATED DUCT; FINISH TO MATCH ADJ. PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP. SUSPENDED TRACK LIGHTING FINISH BLACK; TYP.
PENDANT LIGHT FIXTURES; TYP.
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF
G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02
20' - 9" A.F.F. 2ND FLOOR 19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
11' - 0" A.F.F. STOREFRONT DISPLAY 10' - 11" A.F.F. T.O. STOREFRONT V.I.F.
NEW WOOD DECORATIVE BEAMS; COORD. W/ RCP; FINISH TO MATCH WD-02
CASUAL/ TAILORED SHOP 03
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER
CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550 STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
8' - 2" A.F.F. B.O. ENTRY SOFFIT VIF
DISPLAY WINDOW 02
EXISTING STOREFRONT TO REMAIN
RETAIL TENANT
PT-01A
OWNER'S REPRESENTATIVE
2 A-502
96" MAX
11' - 0"
8' - 8"
OPEN TO VESTIBULE BEYOND
7' - 10"
FINISHED TRANSITION
GL-02
11' - 5" A.F.F. LIGHT COVE
SPEAKER MOUNTING, TYP.
BOH 08
7' - 0"
11' - 3"
PT-01A
16' - 0"
15' - 0" MIN.
LOUNGE 04
WD-02
B.O. PENDANT, TYP.
PT-01A
B.O. DUCT, TYP.
PT-01A
13' - 3" A.F.F. B.O. TRACK 11' - 9" A.F.F. B.O. BEAMS
PT-02
14' - 0"
WALL MOUNTED CAMERA
5 A-501
SUSPENDED J-BOX, TYP.
PT-02
16' - 0" A.F.F. B.O. SUSPENED J-BOX
CUT CORD LENGTHS IN FIELD AS REQ'D
5' - 11 3/4" VIF
NEW WOOD DECORATIVE BEAMS; COORD W/ RCP; FINISH WD-02
TELE/ DATA BOARD W/ FOLDING DESK
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
1' - 6" A.F.F. KNEE WALL 0' - 0" A.F.F. FINISHED FLOOR
B-02
BOH SHELVING
2
B-01
FREE-STANDING FITTING ROOMS BY F.C.
NEW FIXTURE BY F.C.; COORD. IN-WALL BLOCKING AND FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYP. DIMENSIONS SHOWN
SECTION B SCALE: 3/8" = 1'-0"
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF
PENDANT LIGHT FIXTURE; TYP.
PAINT-GRADE INTERNALLY INSULATED DUCT; FINISH TO MATCH ADJ. PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP.
SUSPENDED TRACK LIGHTING FINISH BLACK; TYP.
CHANDELIER TBD (RETAIL TENANT); G.C. TO PROVIDE LAMPS VERIFY TYPE W/ TENANT PRIOR TO PURCHASE 20' - 9" A.F.F. 2ND FLOOR
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
WALL MOUNTED CAMERA G.C. TO PAINT HOUSING TO MATCH ADJ. FINISH PT-01A
G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; REF. ELECTRICAL AND STRUCTURAL DWGS
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
NEW WOOD DECORATIVE BEAMS; COORD W/ RCP; FINISH TO MATCH WD-02
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 10'-3" AFF
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 11'-3" AFF
PT-02 PT-02
PT-01A
BOH 08
PT-01A
11' - 0" A.F.F. LOUNGE CEILING
B.O. DUCT, TYP.
PROJECT NO.: 218259
11' - 3"
GL-02
B.O. CHANDELIER
8' - 8"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
10' - 3"
B.O. PENDANT, TYP.
8' - 8"
15' - 0" MIN.
SPEAKER MOUNTING, TYP.
GL-02
14' - 0"
CASUAL/ TAILORED SHOP 03
12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS
LOUNGE 04
PT-01A
10' - 3"
NEW RETAIL TENANT LOGO: 15"H COLORED LED ILLUMINATED NEON LOOK LETTERS. EACH LETTER TO HAVE INDIVIDUAL WHITE METAL BACKS. EACH LETTER TO BE ENCLOSED IN INDIVIDUAL, NON REFLECTIVE CLEAR ACRYLIC BOXES. G.C. TO SUSPEND EACH SIGN BOX FROM INTERIOR CEILING AT TWO POINTS WITH LETTERS CENTERED IN THE WINDOW. G.C. TO PROVIDE CONCEALED J-BOX AND ACCESS AT INTERIOR. COORDINATE INSTALL AND LOCATION WITH SIGNAGE VENDOR. SIGNAGE TO BE CONTROLLED BY 24/7 PROGRAMMABLE TIME CLOCK. SIGNAGE FILED UNDER SEPARATE PERMIT
DATE: 02/27/2019 DRAWN BY: NK, VR CHECKED BY: JSP AREA: 1,400 SF
#
1
SECTION A SCALE: 3/8" = 1'-0"
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 10'-3" AFF
HOLD
10"
TYP
1' - 6"
HOLD
10"
PT-01A
NEW FIXTURE BY F.C.; COORD. IN-WALL BLOCKING AND FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYP. DIMENSIONS SHOWN
STAMP
FREE-STANDING FITTING ROOMS BY F.C.
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
0' - 0" A.F.F. FINISHED FLOOR
BOH SHELVING
BUILDING SECTIONS
A-300
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
ARCHITECT
G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02 WALL MOUNTED SPEAKER WITH CONCEALED INWALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKER ARE INSTALL TOWARD SALES FLOOR; MOUNT @ 14'-0" B.O.J-BOX
PT-02
5' - 11 3/4" PT-01A
5"
DECORATIVE BEAMS, FINISH TO MATCH WD-02 13' - 3" A.F.F. B.O. TRACK 11' - 9" A.F.F. B.O. BEAMS & PAINT LINE 11' - 0" A.F.F. SALES CEILING 20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" AFF
STRUCTURAL ENGINEER
ENGINEERING
5' - 8"
3" F.01
8' - 8"
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W / FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN
WD-01
1' - 0"
F.03
B-01 PT-01B
1' - 0"
TYP.
1' - 6"
TYP.
1' - 6"
1' - 0"
HOLD
10"
2' - 0"
NEW DEDICATED DUPLEX RECEPTACLE
FLUSH WHITE BUTTON TYPE TEMPERATURE SENSOR
2
LICENSE # C-4550
OSBORN
5' - 0"
1' - 0" 1' - 0" 48"AFF MAX 2' - 0"
1 A-502
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
MT-01
1' - 0"
NEW DUPLEX RECEPTACLE BEHIND
PT-01A
10' - 3"
1' - 0"
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION.
F.01
1' - 0"
1' - 0"
MQ
CASE ENGINEERING, INC.
5' - 0"
5' - 8"
MEP ENGINEER
TM
B.O. PENDANT, TYP
3"
16' - 0"
2' - 4"
14' - 0"
A.03
1/2"
SPEAKER MOUNTING, TYP.
PT-01A
SUSPENDED J-BOX, TYP.
2 A-502
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
0' - 0" A.F.F. FINISHED FLOOR
NEW DUPLEX RECEPTACLE
SALES - SOUTH SCALE: 1/2" = 1'-0"
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F. G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKER ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF
PT-02
PAINT- GRADE INTERNALLY INSULATED SPIRAL STEEL DUCT BY G.C.; FINISH: PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP. NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF.
16' - 0" A.F.F. B.O. SUSPENED J-BOX
CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D
5' - 11 3/4"
PT-02
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR, PT-01A MOUNT @ 11'-0" AFF
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
NEW SURFACE MOUNTED TRACK LIGHTING AT LIGHT COVE. FINISH: WHITE.
NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF.
OWNER'S REPRESENTATIVE
RETAIL TENANT
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 10'-3" AFF
CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D
16' - 0" A.F.F. B.O. SUSPENED J-BOX
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
DECORATIVE BEAMS, FINISH TO MATCH WD-02
STAMP
PT-02 13' - 3" A.F.F. B.O. TRACK
11' - 9" A.F.F. B.O. BEAMS & PAINT LINE 11' - 0" A.F.F. ENTRY CEILING
WD-02
NEWDUPLEX RECEPTACLE
1
SALES - NORTH SCALE: 1/2" = 1'-0"
7"
96" MAX
F.01
EXISTING FIRE-ALARM SPEAKER STROBE TO REMAIN; G.C. TO CONFIRM EXISTING IS WHITE; ADD-ALT: IF NOT WHITE REPLACE W/ WHITE EQUIVALENT NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W / FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01 B-01 PT-01B
1' - 0"
TYP.
NEW RETAIL TENANT LOGO: 15"H COLORED LED ILLUMINATED NEON LOOK LETTERS. EACH LETTER TO HAVE INDIVIDUAL WHITE METAL BACKS. EACH LETTER TO BE ENCLOSED IN INDIVIDUAL, NON REFLECTIVE CLEAR ACRYLIC BOXES. G.C. TO SUSPEND EACH SIGN BOX FROM INTERIOR CEILING AT TWO POINTS WITH LETTERS CENTERED IN THE WINDOW. G.C. TO PROVIDE CONCEALED J-BOX AND ACCESS AT INTERIOR. COORDINATE INSTALL AND LOCATION WITH SIGNAGE VENDOR. SIGNAGE TO BE CONTROLLED BY 24/7 PROGRAMMABLE TIME CLOCK. SIGNAGE FILED UNDER SEPARATE PERMIT
5' - 8" 1' - 0"
F.03
B.O. DUCT, TYP.
15' - 0" MIN.
8' - 8" A.F.F. T.O. ENTRY SOFFIT
5' - 0"
B.O. PENDANT
1' - 6"
B-01 PT-01B
1' - 0"
5' - 0"
8' - 8"
11' - 0"
1' - 0"
F.01
PT-01A
SPEAKER MOUNTING, TYP.
MT-01
10' - 10"
14' - 0"
WD-01
7"
CEILING MOUNTED EXIT SIGN CENTERED OVER DOOR.
SUSPENDED J-BOX, TYP.
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W / FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN
16' - 0"
20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" A.F.F.
0' - 0" A.F.F. FINISHED FLOOR
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: Author CHECKED BY: Checker AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
INTERIOR ELEVATIONS CASUAL SHOP & TAILORED SHOP
A-301
ARCHITECT
G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F. PAINT- GRADE INTERNALLY INSULATED SPIRAL STEEL DUCT BY G.C. FINISH: PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP.
NEW RETURN AIR GRILLE; MOUNT AS HIGH AS POSSIBLE; B.O. GRILLE AT 14' - 6" AFF MIN. PAINT TO MATCH ADJ FINISH. PT-02
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF. DECORATIVE BEAMS, FINISH TO MATCH WD-02 16' - 0" A.F.F. B.O. SUSPENED J-BOX
16' - 0"
& PAINT LINE
8"
11' - 0" A.F.F. SALES CEILING 20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" AFF
MEP ENGINEER
CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550 STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
PT-01A
F.01
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN. WD-01 MT-01
F.15 BS
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
2
SALES - WEST SCALE: 1/2" = 1'-0" 19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
PAINT-GRADE INTERNALLY INSULATED SPIRAL STEEL DUCT BY G.C. RETAIL TENANT G.C. TO PAINT PT-02 B.O. DUCT AT 15'-0"AFF MIN.; MOUNT AS HIGH AS POSSIBLE, TYP.
NEW SUSPENDED TRACK LIGHTING, FINISH BLACK TYP. MOUNT @ 13' 3" AFF.
G.C. TO SUSPEND J-BOXES AT 16'-0"AFF FOR PENDANT LIGHT POWER; FINISH TO MATCH ADJ CEILING TYP. PT-02
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
F.16
RETAIL TENANT
8' - 8"
OPEN TO LOUNGE BEYOND
BS
11' - 9" A.F.F. B.O. BEAMS
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
11' - 0"
TYP.
B.O. RETURAN AIR GRILLE
14' - 6" MIN.
SPEAKER MOUNTING, TYP.
F.01
14' - 0"
PT-01A
15' - 0" B.O. DUCT MIN.
PT-01A
13' - 3" A.F.F. B.O. TRACK
SUSOENDED J-BOX, TYP.
WD-02
CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D
5' - 11 3/4"
PT-02
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , MOUNT @ 11'-0" AFF G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A
B.O. PENDANT
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL JBOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKER ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF
OWNER'S REPRESENTATIVE
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL JBOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'-0" AFF
PT-02
5' - 11 3/4"
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL JBOX; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; MOUNT @ 14'- 0" AFF WD-02 PT-01A
CEILING MOUNTED EXIT SIGN CENTERED OVER TRANSITION DOOR. MOUNT @11'-0" A.F.F..
CUT CORD LEGTH TO SIZE IN FIELD AS REQ'D
16' - 0" A.F.F. B.O. SUSPENED J-BOX DECORATIVE BEAMS, FINISH TO MATCH WD-02
13' - 3" A.F.F. B.O. TRACK
11' - 8" A.F.F. WALL WASHER COVE 11' - 0" A.F.F. ENTRY CEILING WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD, MOUNT @ 10'-3" AFF,G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A
SUSPENDED J-BOX, TYP.
1' - 6"
MQ
3' - 4"
1
SALES - EAST SCALE: 1/2" = 1'-0"
WD-01
1' - 6"
4' - 2"
3' - 8"
48"AFF MAX
F.10
10' - 3"
2' - 6"
1' - 0" B.O. PENDANT
8' - 8"
1' - 0"
1' - 0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
8' - 2" A.F.F. B.O. ENTRY SOFFIT VIF
PROJECT NO.: 218259
BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE IN-WALL FRT BLOCKING AS REQ'D
DRAWN BY: Author
A.05
1' - 0"
EXISTING STOREFRONT DOOR TO REMAIN; G.C. TO CONFIRM EXISTING LOCK IS SFIC AND PROVIDE NEW 'BEST' LOCK CORE OR APPROVED EQUAL 7-PIN SMALL FORMAT INTERCHANGEABLE CORE AND 6 SETS OF KEYS; IF EXISTING LOCK IS NOT SFIC; G.C. TO REPLACE LOCK AND CORE PER ABOVE; FINISH: COLOR TO MATCH ADJ
8' - 8" A.F.F. T.O. ENTRY SOFFIT
PT-01A
1' - 6"
16' - 0"
B.O. DUCT, TYP.
15' - 0" MIN
SPEAKER MOUNTING, TYP.
14' - 0"
20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. B.O. PENDANT MOUNTED @ 8'-8" A.F.F.
EXISTING FIRE ALARM PULL STATION TO REMAIN
STAMP
20" CEILING PENDANT LIGHT. FINISH: GALVANIZED. 24" STEMS REQ; B.O. PENDANT MOUNTED @ 8'-8" A.F.F.
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01
MT-01
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION. F.01 B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
DATE: 02/27/2019 CHECKED BY: Checker AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
INTERIOR ELEVATIONS CASUAL SHOP & TAILORED SHOP
A-302
ARCHITECT
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
OWNER'S REPRESENTATIVE
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER
CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550 STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
7' - 11" 7 A-500
PT-01B WD-01
F.22 A.03
1' - 0"
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02
1' - 0 1/4"
11' - 0" A.F.F. LOUNGE CEILING
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD ,MOUNT @ 10'-3" AFF, G.C. TO PAINT METAL HOUSING TO MATCH ADJ. PT-01A
PT-01A
1"
F.22
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02
6' - 5 1/4"
MIRROR HOLD
1' - 0"
10"
1' - 0"
GL-02
1' - 0"
SO
CT
LOUNGE - WEST
2
SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR
NEW DUPLEX RECEPTACLE STAMP
LOUNGE - SOUTH SCALE: 1/2" = 1'-0"
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT @ 7'-10"AFF FINISH WHIP TO MATCH ADJ SURFACE PT-01A
11' - 0" A.F.F. LOUNGE CEILING
11' - 0" A.F.F. LOUNGE CEILING
6"
8"
2' - 0"
FB-01 FREE STANDING FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS
1' - 6"
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
TYP.
3' - 0" FB-01
B-01 PT-01B
MIRROR
1' - 0"
3"
8' - 8"
04
1' - 11 1/4"
1' - 0"
PT-01A
PT-01A
B.O. CHANDELIER
DOOR TO BOH
OPEN TO ADA FR ROOM BEYOND
6' - 10"
CURTAIN ON RECESSED TRACK AT ADA FITTING ROOM
FINISHED TRANSITION
7' - 0"
GL-02
4
2' - 4"
FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C.; BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01
A.03
NEW CUSTOM DOOR FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE SILENCERS AND MIRROR; G.C. TO COORD. ROUGH OPENING DIMENSIONS WITH APPROVED FINAL SHOP DWGS. WD-01 GL-02
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , MOUNT @ 10'-3" AFF, G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A
PT-01A
NEW 3-WAY MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. INWALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
EQ
6"
6"
PT-01A
MIRROR
MIRROR
GL-02
6' - 6"
1' - 7" 1' - 0" 1' - 7"
1' - 0 7/8"
NEW 3-WAY MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION MT-01 GL-02
NEW DUPLEX RECEPTACLE B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
BS
LOUNGE - EAST
2' - 7 7/8"
TYP.
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
DATE: 02/27/2019
1' - 6"
TYP.
1' - 6"
B-01 PT-01B
OPENING TO VESTIBULE
1
LOUNGE - NORTH SCALE: 1/2" = 1'-0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259
7' - 4 3/8" MIRROR
NEW DUPLEX RECEPTACLE
48 AFF MAX. B-01 PT-01B
7' - 0"
FIRE EXTINGUISHER
F.16
FINISHED TRANSITION
MIRROR
G.C. TO PROVIDE 3/4"THK CONCEALED IN-WALL FRT PLYWOOD BLOCKING FOR FUTURE SIGNAGE LOCATION
EQ
1' - 0"
10' - 3"
1' - 0 7/8"
1' - 10"
PT-01A
OPENING TO SALES BEYOND
F.15
SCALE: 1/2" = 1'-0"
3' - 6"
EQ
REF-1
3
EQ
1' - 0"
A.01
PT-01A
FUTURE ILLUMINATED SIGNAGE LOCATION 4' - 6"
4' - 0"
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT @ 7'-10"AFF; PAINT WHIP TO MATCH ADJ. FINISH PT-01A
RETAIL TENANT
PT-01A
PT-01A
FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C., INSTALLED BY G.C.; G.C. TO PROVIDE 3/4" FRT PLYWOOD INWALL BLOCKING BY G.C. BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
CHANDELIER TBD (RETAIL TENANT); G.C. TO PROVIDE LAMPS VERIFY TYPE W/ TENANT PRIOR TO PURCHASE
11' - 0" A.F.F. LOUNGE CEILING
DRAWN BY: Author CHECKED BY: Checker AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
INTERIOR ELEVATIONS LOUNGE & FITTING ROOMS
A-303
ARCHITECT
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
OWNER'S REPRESENTATIVE
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER
CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550 STRUCTURAL ENGINEER
TM
OSBORN ENGINEERING
9' - 0" A.F.F. VESTIBULE CEILING
PT-01A
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01
PT-01E
DOOR TO ADA RESTROOM
EQ
EQ
1' - 0"
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01
EQ
NEW FIXTURES BY F.C. COORD IN WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN WD-01 MT-01
EQ
2' - 6"
8 7/8"
PT-01A 5' - 8"
EQ
7' - 0"
5' - 0"
EX-03
0' - 0" A.F.F. FINISHED FLOOR
NEW DUPLEX RECEPTACLE
OPENING TO LOUNGE
B-01 PT-01B
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
TYP
3' - 8"
1' - 11 1/2"
1' - 6"
B-01 PT-01B
1' - 0"
4' - 2"
BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE INWALL FRT BLOCKING AS REQ'D. MT-01
1' - 0"
3' - 0"
5' - 0"
3' - 6 1/2"
B-01 PT-01B
WALL MOUNTED EXIT SIGN CENTERED OVER TRANSITION DOOR. MOUNT @8'-6" A.F.F.
EQ
8' - 6"
EXISTING ADA COMPLIANT RESTROOM SIGN BY LANDLORD'S G.C.
1' - 0"
PT-01E
PT-01A
1' - 0"
PT-01A
8' - 6"
9' - 0" A.F.F. VESTIBULE CEILING
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
9' - 0" A.F.F. VESTIBULE CEILING
FINISHED TRANSITION
9' - 0" A.F.F. VESTIBULE CEILING
1' - 6"
WALL MOUNTED EXIT SIGN CENTERED OVER TRANSITION DOOR. MOUNT @ 8'-6" A.F.F.
RETAIL TENANT
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
EXISTING RESTROOM DOOR TO REMAIN; G.C. TO PAINT AND REPLACE EXISTING HARDWARE W/ BLACK HARDWARE REF. DOOR SCHEDULE
STAMP
VESTIBULE WEST
8
6
SCALE: 1/2" = 1'-0"
VESTIBULE NORTH
4
SCALE: 1/2" = 1'-0"
VESTIBULE EAST
2
SCALE: 1/2" = 1'-0"
VESTIBULE SOUTH SCALE: 1/2" = 1'-0"
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION.
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
7
SCALE: 1/2" = 1'-0"
5
ADA FITTING NORTH SCALE: 1/2" = 1'-0"
3
ADA FITTING SOUTH SCALE: 1/2" = 1'-0"
1
ADA FITTING WEST SCALE: 1/2" = 1'-0"
HOLD
1' - 9"
DATE: 02/27/2019 DRAWN BY: Author CHECKED BY: Checker
2' - 0"
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
6"
4' - 0"
6"
PROJECT NO.: 218259
AREA: 1,400 SF
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
CURTAIN ON RECESSED TRACK AT ADA FITTING ROOM
ADA FITTING EAST
F.12
4"
HOLD
ADA BENCH BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN WALL FRT PLYWOOD BLOCKING AS REQ'D WD-01
HOLD 3' - 0"
2' - 0"
1' - 5"
4" 1' - 5"
B-01 PT-01B
1' - 2"
F.12
1' - 0"
1' - 0"
1' - 0" 1' - 0"
6"
3 1/2"
A.05
3' - 6"
4' - 0"
5' - 0"
HOLD
ADA BENCH BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN WALL FRT PLYWOOD BLOCKING AS REQ'D WD-01
BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE IN-WALL FRT BLOCKING AS REQ'D MT-01
3" 3" 3" 3" 1' - 0" A.04
1' - 8"
2' - 10" 4' - 0"
HOLD
4' - 0"
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
A.04
PT-01A
3' - 6"
2' - 5"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
HOLD
2' - 10"
1' - 9"
HOLD
1' - 6 1/2"
9' - 0" A.F.F. FITTING ROOM CLG
ADA HANG BAR FURNISHED BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D. MT-01
PT-01A
A.02
2' - 5"
B-01 PT-01B
10"
ADA HANG BAR FURNISHED BY F.C. INSTALLED BY G.C.;G.C. TO PROVIDE INWALL FRT PLYWOOD BLOCKING AS REQ'D. MT-01
HOLD
A.05
BLACK METAL HOOKS FURNISHED BY F.C., INSTALLED BY G.C., G.C. TO PROVIDE INWALL FRT BLOCKING AS REQ'D MT-01
TYP.
HOLD 5' - 0"
4' - 0"
1' - 0"
GL-02
A.02
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02
5' - 0"
ADA HANG BAR FURNISHED BY F.C. INSTALLED BY G.C.;G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D. MT-01
MIRROR
PT-01A
1' - 0"
1' - 11 1/4"
MIRROR
1' - 0" 1' - 0"
7 1/8"
1' - 0"
OPENING TO LOUNGE
2' - 4"
2' - 0"
FINISHED TRANSITION
7' - 0"
1' - 0"
1' - 0"
2 7/8"
5' - 11 1/4"
A-500
PT-01A
1' - 0"
NEW MIRROR FRAME BY F.C., G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION. MT-01 GL-02
7
9' - 0" A.F.F. FITTING ROOM CLG
9' - 0" A.F.F. FITTING ROOM CLG
5' - 0"
9' - 0" A.F.F. FITTING ROOM CLG
INTERIOR ELEVATIONS ADA FITTING ROOM/ VESTIBULE & RESTROOM
A-304
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
NEW SUPPLY AIR GRILLE; COORD. W/ MEP DWGS; MOUNT AS HIGH AS POSSIBLE; B.O. GRILLE AT 14' - 6" AFF MIN. PAINT TO MATCH ADJ FINISH. PT-02
PT-02
PT-02
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 11'-3" AFF
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR, PT-01A MOUNT @ 11'-3" AFF
PT-02
4' SUSPENDED LINEAR LED LIGHTS, TYP. FINISH: WHITE.
6"
6"
12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS
12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS
SHB
SHBH
SHBH
SHBH
BST
SHB
SHB
SHB
3' - 4"
EXISTING ELECTRICAL PANELS TO REMAIN' G.C. TO RE-CIRCUIT AS REQUIRED
PT-01B
G.C. TO RELOCATE EXISTING DISCONNECT SWITCH NEXT TO NEW DISCONNECT SWITCH REF. MEP DWGS.
TDSH
1' - 4"
PL.06
SH16 B16
FIRE RATED EXIT DOOR TO PARKING GARAGE
EXISTING FIRE ALARM PULL STATION TO REMAIN
CB
KB
11' - 3"
EL
B16
SHBH
INFILL AT BACK WALL TO BE EXISTING BY LANDLORD
VOLUME CONTROLS; MOUNT @ 48" AFF MAX.
4
BOH WEST SCALE: 1/2" = 1'-0"
NEW TELE/DATA BOARD 3/4" FRT PLYWOOD, PAINTED TO MATCH ADJACENT FINISH PT-01A
48"AFF MAX
42" AFF MAX
SWITCHBANK
48"AFF MAX
WATER COOLER
48" MAX.
5' - 0"
4' - 6"
SHB
EMPLOYEE LOCKER
UH
02 PT-01B
FDSK
SECURITY KEYPAD MOUNT @ 48" AFF MAX.
NEW TIMECLOCK MOUNT @ 48" AFF MAX.
8" 9' - 10"
BOH SOUTH
2
SCALE: 1/2" = 1'-0"
4' - 0"
TDSH: WALL MOUNTED RECEIVER SHELF G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.
3
PLAYLIST GENERATION - AUDIO RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
4
ADT MONITOR G.C. TO COORD. & SUPERVISE VENDOR INSTALL
5
AUDIO CONTROLLERS - MOUNT AT 48" AFF MAX. G.C. TO COORD. & SUPERVISE VENDOR INSTALL
6
BANDWAVE - PEPWAVE - CELLULAR ROUTER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
7
RETAIL NEXT - ALLIED TELESIS - POE SWITCH (ONLY OCCURS AT MEDIUM TO LARGE STORES) G.C. TO COORD. & SUPERVISE VENDOR INSTALL
8
ISP INTERNET HAND-OFF G.C. TO COORD. & SUPERVISE VENDOR INSTALL
9
RETAIL NEXT - HIK VISION G.C. TO COORD. & SUPERVISE VENDOR INSTALL
10
POWER GEAR SURGE PROTECTOR G.C. TO FURNISH AND INSTALL
11
ADT SWITCH G.C. TO COORD. & SUPERVISE VENDOR INSTALL
12
ADT MAIN BOX G.C. TO COORD. & SUPERVISE VENDOR INSTALL
13
CISCO MERAKI FIREWALL - G.C. TO SUPERVISE VENDOR INSTALL
ADT ALARM SIREN G.C. TO COORD. & SUPERVISE VENDOR INSTALL
16
ADT VIDEO RECORDER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
0' - 0" A.F.F. FINISHED FLOOR
1
TELE/DATA BOARD W/ DESK SCALE: 1" = 1'-0"
5"
5"
1' - 4 1/2"
EQ
EQ
4
3
NEW TELE/DATA BOARD 3/4" FRT PLYWOOD, PAINTED TO MATCH 2 ADJACENT FINISH PT-01A
15
STAMP
1
13
6
16
12
8
7
9 11
KB: KEYBOX - MOUNT AT 48" AFF MAX. G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.
15
5"
3"
SOUND GENERATION - AMP RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
1' - 4 1/2"
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
TYP.
1' - 6"
NEW DUPLEX RECEPTACLE 0' - 0" A.F.F. FINISHED FLOOR
SCALE: 1/2" = 1'-0"
2
14
RETAIL TENANT
1' - 4" 4' - 6"
1' - 0"
B-02
BOH NORTH
FIRE EXTINGUISHER; REF. G-003 FOR MOUNTING DETAIL
B-02
11' - 3"
SHB
14
7' - 9"
EXISTING FIRE ALARM SPEAKER STROBE TO REMAIN
BOH SHELVING, TYP. SH16
SHB
SHBH
6' - 0"
8"
BR
SHBH SHB
SHBH
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 5
DATE: 02/27/2019
10
DRAWN BY: Author CHECKED BY: Checker AREA: 1,400 SF
#
2 1/2"
3' - 7"
2 1/2"
MIN. 1' - 6"
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A MOUNT @ 11'-3" AFF
PT-01A
1 A-305
B16
B16
1' - 3"
12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS
SH16
B16
MOUNT ALL LOW VOLTAGE EQUIP. ABOVE 36" AFF
EXISTING EXIT SIGN / EM COMBO TO REMAIN
BOH SHELVING, TYP.
SH16
MOUNT KEYBOX, AUDIO CONTROLS, AND KEPAD AT 48" AFF MAX. 3' - 0"
PT-02
SH16 B16
SH16
MIN.
4' SUSPENDED LINEAR LED LIGHTS, TYP. FINISH: WHITE.
PT-02
BST
B16
TELE/DATA BOARD EQUIP. LEGEND 1
G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; REF. ELECTRICAL AND STRUCTURAL DWGS.
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
B16
4' - 6"
5' - 0"
4' - 6"
1' - 0"
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
OSBORN
0' - 0" A.F.F. FINISHED FLOOR
5
PT-01A
SH16
0' - 0" A.F.F. FINISHED FLOOR
B-02
TM
SH16
SH16 B16
B-02
NEW DUPLEX RECEPTACLE
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
SHB
1' - 6"
TYP.
1' - 6"
3' - 0" TYP.
1' - 6"
THERMOSTAT; MOUNT @ 48" AFF MAX.
CASE ENGINEERING, INC.
SH16
3' - 4"
3' - 4"
SHBH
SCALE: 1/2" = 1'-0"
PT-01A
1' - 4"
B16
BOH EAST
PT-02
UH
SH16
SHB
MEP ENGINEER
BOH SHELVING, TYP.
9' - 10"
1' - 4"
SH16 B16
8"
B16
1' - 0"
3"
4' - 6"
6
REFRIGERATOR NEW DUPLEX RECEPTACLE BEHIND
B16
SHB
REF-2
B-02
B16
4' - 0"
B16
B16
7' - 0"
SHB
SH16
B16
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
STRUCTURAL ENGINEER
BST
SH16
9' - 10"
1' - 0" DOOR TO LOUNGE 04
8' - 0"
9' - 10"
SH16
PL.05
1' - 1"
SH16 B16
1' - 4"
PL.04
B16
WD-01
1' - 0"
SH16
3' - 4"
1' - 6" SHB
BR
BOH SHELVING, TYP.
OWNER'S REPRESENTATIVE
LICENSE # C-4550
SH16
SHB
SH16
PT-01A
BR
SH16
BST
3' - 4" PT-01A
BST
B16
B.O. GRILLE, TYP.
BR
8"
SH16
PT-01B
PW-01
BR
11' - 3"
BST
12' - 0" A.F.F. BOH PAINT LINE & BOH LIGHTS
PT-01A
WALL MOUNTED SECURITY CAMERA, PROVIDED BY OWNER, COORD. W/ ADT, G.C. TO PROVIDE PULL STRING TO BOH TELE/DATA BOARD , MOUNT @ 11'-3" AFF, G.C. TO PAINT METAL HOUSING TO MATCH ADJ. COLOR PT-01A
11' - 3"
BST SH16 B16 SHB
1' - 0"
NEW WATER HEATER; G.C. TO PROVIDE WHITE SHELF AND MOUNT ABOVE MOP SINK IN B.O.H. 90" MIN AFF AS HIGH AS POSSIBLE; PROVIDE ADDITIONAL SUPPORT/BRACING AS REQ'D; COORD WITH MEP DRAWINGS.
BR
14' - 6" MIN
8"
PT-01A BR
ARCHITECT
G.C. TO SUSPEND EXISTING FLOOR MOUNTED TRANSFORMER; REF. ELECTRICAL AND STRUCTURAL DWGS.
NEW RETURN AIR GRILLE; COORD. W/ MEP DWGS; MOUNT AS HIGH AS POSSIBLE; B.O. GRILLE AT 14' - 6" AFF MIN. PAINT TO MATCH ADJ FINISH. PT-02
PT-02
19' - 9" A.F.F. B.O. EXISTING DECK V.I.F.
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
INTERIOR ELEVATIONS BOH DETAILS
A-305
2' - 2"
HOLD 2
PT-01D
4
3' - 6"
1' - 0"
6
PT-01D CAB
2' - 4"
GB
EXISTING WALL MOUNTED LAVATORY BY LL'S G.C.; EXPOSED PIPES SHALL BE INSULATED TO PROTECT AGAINST CONTACT; NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY; COORDINATE W/ MEP DWGS.
8
EXISTING AUTOMATIC FAUCET BY LL'S G.C.; COORDINATE W/ MEP DWGS.
9
EXISTING W.C. W/ OPEN-FACE ELONGATED TOILET SEAT BY LL'S G.C. COORDINATE W/ MEP DWGS.
10 EXISTING GRAB BARS BY LL'S G.C.; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQUIRED 11 EXISTING SURFACE MOUNTED TOILET PAPER DISPENSER BY LL'S G.C.; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D
SCALE: 1/2" = 1'-0"
22 EXISTING COAT HANGER BY LL'S G.C; G.C. TO PROVIDE IN-WALL BLOCKING AS REQ'D
(15" MIN)
1' - 6"
2' - 10"
3' - 5" 11"
SCALE: 1" = 1'-0"
EXISTING ADA GRAB BARS
MR
EXISTING RESTROOM MIRROR
SD
18"W X 36"H
EXISTING SOAP 6 1/8"L x 7"W x 3 5/16"D DISPENSER EXISTING RECESSED 19"H X 13"W X 4 1/4"D PAPER TOWEL DISPENSER EXISTING TOILET PAPER 6"W X 4 1/4"D X 2 3/4"H HOLDER
TD TPH
LANDLORD
BOBRICK
MODEL 23" x 23" 2 DOOR WALL MOUNT CABINET B-233
LANDLORD
BOBRICK
B-6806-18, B-6806-36, B-6806-42
LANDLORD
MANUFACTURER TOPEAKMART
BOBRICK
B-165 1836
LANDLORD
BOBRICK
B-4112
LANDLORD
BOBRICK
B-35903
LANDLORD
BOBRICK
B-264
FINISH WHITE
STAINLESS STEEL POLISHED STAINLESS STEEL BRUSHED STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL CHROME
QTY NOTES / REMARKS 1 FINISH: WHITE; G.C. TO PROVIDE AND INSTALL, CENTERED ABOVE W.C. AT 4'-3" AFF EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS EX G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS
EX EX EX EX
3/4"
DESCRIPTION EXISTING RESTROOM SINK
PL.02
EXISTING RESTROOM SINK 2 "W X 5 1/2"D X 6 3/4"H FAUCET EXISTING RESTROOM 17 1/2"W X 30 5/8"D X 30 TOILET 11/16"H
PL.03 PL.04
SERVICE SINK
PL.05
SERVICE SINK FAUCET
PL.06
WATER COOLER
DIMENSION 20 1/2"W X 18 1/4"D
RESPONSIBILITY MANUFACTURER LANDLORD AMERICAN STANDARD
MODEL LUCERNE 0356.041
FINISH WHITE
QTY EX
GYP. CEILING PT-01C
CHROME
EX
LANDLORD
AMERICAN STANDARD
ASTUTE VORMAX 727AA.121
WHITE
EX
21"W X 21 1/2"D X 44 1/2"H 8" SPREAD
G.C.
TURBO AIR
TSA-1MOP
1
G.C.
B-0674-RGH
1
COORD. W/ MEP DWGS.
11 3/4"W x 14 1/2"D x 50"H
G.C.
T&S BRASS AND BRONZE WORKS, INC. QUENCH
STAINLESS STEEL CHROME
G.C TO SPECIFY RIGHT HANDED LEVER; G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. COORD. W/ MEP DWGS.
Q7 FREESTANDING
BLACK
1
COORD. W/ MEP DWGS.
P-4 R-1
MODEL APR-25-LC-UI
FINISH WHITE
QTY 1
11W
G.C.
AAMSCO
LED50SYM-24K-PC
1
17W
G.C.
SOLAIS LIGHTING
XR3NC-D-XM20-30K-1450-WH/WH
POLISHED CHROME WHITE
C-02
DESCRIPTION PAINTED WOOD WALL BASE EXISTING CONCRETE PREP FOR CUSTOM FINISH
LOCATION RESPONSIBILITY RESTROOM WALL BASE G.C.
RESTROOM FLOOR
MANUFACTURER G.C. G.C. TENANT'S
LANDLORD / G.C.
UNCONVENTIONAL FLOORING
PT-01C PT-01D
INTERIOR PAINT INTERIOR PAINT
RESTROOM CEILING RESTROOM WALL
G.C. G.C.
BENJAMIN MOORE BENJAMIN MOORE
PT-01E
INTERIOR PAINT
RESTROOM DOOR/ TRIM
G.C.
BENJAMIN MOORE
R-1
EM-1 16
STAMP
19
CLG
SD
B-01
PAINTED WOOD TRIM FOR WALL BASE BY RETAIL TENANT'S G.C., AT RESTROOM
3
EQ
B-01 TRIM PROFILE
2
SCALE: 6" = 1'-0"
C
NOTES / REMARKS G.C. TO PAINT TO MATCH ADJ. FINISH
B
20' - 3 5/8" 5' - 7 3/4"
V.I.F. 7' - 11 3/8"
6' - 8 1/2"
HOLD
HOLD
EQ
EQ
EQ
RESTROOM REFLECTED CEILING PLAN SCALE: 1/2" = 1'-0"
A
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019
MTD. @ 6-8" AFF CENTERED ABOVE MIRROR
DRAWN BY: RA, NK
2
RESTROOM FINISHES FINISH TAG A B-01
R-1
ST
NOTES / REMARKS G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. COORD. W/ MEP DWGS.
SELECTRONIC 6055.102
MANUFACTURER EVENLIGHT-APERION
20
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS
AMERICAN STANDARD
RESPONSIBILITY G.C.
21
9' - 0" AFF
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS RECESSED INTO WALL
LANDLORD
W/V 25W
RESTROOM
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS
RESTROOM LIGHTING FIXTURES DESCRIPTION SURFACE RECESSED EMERGENCY LIGHT ALINEA LINEAR WALL SCONCE 3"Ø DIMMABLE LED RECESSED DOWNLIGHT
3/8"
FINISHES PAINT GRADE POPLAR; REF. PLAN FOR PAINT FINISH
NOTES / REMARKS REFER TO DETAIL 6 FOR TRIM PROFILE
EXISTING CONCRETE FLOOR TO REMAIN LL'S G.C. TO PREP FLOOR PER TENANT'S VENDOR RECOMMENDATIONS FOR NEW GRIND, STAIN, SEAL AND POLISH BY TENANT'S G.C.; CUSTOM STAIN COLOR: CHARCOAL; FINISH: SEMI-GLOSS SIMPLY WHITE OC-117; FLAT COROTECH PRE-CATALYZED WATERBRONE EPOXY V342; COLOR: SIMPLY WHITE OC-117; FINISH: EGGSHELL; LOW VOC COROTECH ACRYLIC DTM ENAMEL - V331; COLOR: SIMPLY WHITE OC-117; FINISH: SEMI-GLOSS; LOW VOC
LL'S G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT; ADD. ALT IF NOT PROVIDED BY LANDLORD, TENANT'S G.C. TO PROVIDE. REF. LANDLORD DWGS. FOR REQUIRED SLAB IN-FILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL
1' - 4"
17
06
PLUMBING FIXTURES TAG PL.01
P-4
18
EQ
GB
1 1/4" W x 1 1/8" D x 1 1/4" H 18"L, 36"L, 42"L
RESPONSIBILITY G.C.
EQ
COAT HOOK
DIMENSIONS 23.2"W x 12.2"" x 23.4
19 NEW SUPPLY GRILLE BY TENANT'S G.C.; COORD. W/ MEP DWGS; LL'S G.C. TO FINISH TO MATCH ADJ. CLG
21 CONCEALED SPRINKLER HEAD W/ WHITE COVER BY LL'S G.C.; COORD. W/ MEP & APPROVED SPRINKLER DWGS.; TENANT'S G.C. TO RELOCATE AS REQUIRED FOR NEW GWB CEILING LAYOUT
ENLARGED RESTROOM PLAN
EQ
CH
17 NEW ALINEA LINEAR LIGHT FIXTURE BY TENANT'S G.C.; CENTER ABOVE RESTROOM MIRROR @ 6'-8" AFF; REF. ELEVATIONS FINISH HOUSING FOR LAMPING IN POLISHED CHROME; LL'S G.C. TO PROVIDE WHIP CONNECTION @ 6-8"AFF AND PAINT EXPOSED WHIP TO MATCH ADJ. FINISH
20 NEW GWB CEILING @ RESTROOM CEILING BY TENANT'S G.C., TENANT'S G.C. TO DEMO EXISTING ACT CEILING AND 2X4 GRID LIGHT; PAINT TO MATCH PT-01C ; (DEDUCT ALT: EXISTING ACT CEILING AND LIGHT TO REMAIN; CONFIRM WITH TENANT PRIOR TO DEMO)
SCALE: 1/2" = 1'-0"
4
HOLD
EQ
DESCRIPTION WALL CABINET
14 NEW G.F.I. DUPLEX MOUNTED @ 46" AFF W/ WHITE COVER PLATE BY LL'S G.C.; COORD. W/ MEP DWGS
18 EXISTING EXHAUST FAN AND GRILLE BY LL'S G.C.; COORD. W/ MEP DWGS; LL'S G.C. TO FINISH WHITE TO MATCH ADJ. CEILING COLOR; TENANT'S G.C. TO RELOCATE AS REQUIRED FOR NEW GWB CEILING LAYOUT
ADA RESTROOM WEST
HOLD
3/8"
TAG CAB
13 EXISTING RECESSED PAPER TOWEL DISPENSER BY LL'S G.C.; PROVIDE CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D
16 CEILING MOUNTED FIRE ALARM STROBE BY TENANT'S G.C.; FINISH WHITE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS
9
RESTROOM ACCESSORIES
12 EXISTING MIRROR; SURFACE MOUNTED & CENTERED ABOVE LAVATORY BY LL'S G.C.; REFLECTIVE SURFACE SYMBOL TAG (NOT FRAME) TO BE MOUNTED AT 40" AFF MAX; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT EM-1 PLYWOOD BLOCKING AS REQ'D
15 NEW SWITCH / OCCUPANCY SENSOR MOUNTED W/ WHITE COVER PLATE @ 46" AFF BY TENANT'S G.C.; COORD. W/ MEP DWGS
PL.03
7' - 0"
EQ
EXISTING CONCRETE FLOOR TO REMAIN; LL'S G.C. TO PREP FLOOR PER TENANT'S VENDOR RECOMMENDATIONS FOR NEW GRIND, STAIN, SEAL AND POLISH BY TENANT'S G.C.; CUSTOM STAIN COLOR: CHARCOAL; FINISH: SEMI-GLOSS; LL'S G.C. TO PROVIDE NEW CONCRETE IN-FILL AT EXISTING SLAB LEAVE OUT; ADD-ALT: IF IN-FILL NOT PROVIDED BY LANDLORD; TENANT'S G.C. TO PROVIDE; REF. LANDLORD DWGS. FOR REQUIRED SLAB IN-FILL DETAILS INCLUDING SOIL PREPARATION AND VAPOR BARRIER REQUIREMENTS
5
11
9"
EQ
6
7
AND REPLACE HARDWARE W/ BLACK
5
5' - 7 3/4"
CHECKED BY: JSP
HOLD
TENANT'S G.C. TO PAINT EXISTING DOOR BY LL'S G.C. PT-01E HARDWARE; REF. DOOR SCHEDULE
ADA RESTROOM SOUTH
8
TPH
0' - 0" A.F.F. FINISHED FLOOR
7' - 4"
5
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
EX-03
3 5/8"
AT RESTROOM FURNISHED AND INSTALLED BY TENANT'S G.C.; TENANT'S G.C. TO
22
SCRIBE
NEW WALL BASE B-01 PAINT PT-01E
0' - 0" A.F.F. FINISHED FLOOR
4"
4
10
1"
LL'S G.C. TO PREP ALL WALLS TO RECEIVE NEW PAINT FINISH AND ENSURE LEVEL 4 FINISH, TENANT'S G.C. TO PAINT ALL WALLS PT-01D
OSBORN
TYP.
30"x48" CLEAR WHEELCHAIR SPACE
5"
3
TM
30" CLEAR
60"Ø TURNING SPACE
7' - 6 3/8"
LL'S G.C. TO USE WATER-RESISTANT GYP. BOARD AT ALL WET AREAS
B-01 PT-01E
B-01 PT-01E
11. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND PLUMBING FIXTURES AND RESTROOM ACCESSORIES; COORD. LOCATIONS WITH MANUFACTURER'S INSTALL RECOMMENDATIONS.
2
HOLD
7" MIN 9" MAX
10. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS.
LEASE LINE
TYP.
STRUCTURAL ENGINEER
60" CLEAR
9. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING.
1
TYP.
OS
C-02
6"
GB
TYP.
1' - 4"
LICENSE # C-4550
60 INCH CLEAR HOLD
2' - 5 1/8"
1' - 6"
8. ALL MATERIALS AND FINISHES MUST BE FIRE-RATED AND HAVE FLAME RESISTANCE COMPLYING WITH LOCAL & STATE CODES.
ENLARGED RESTROOM PLAN KEY NOTES:
10
4' - 6 1/8" ADA RESTROOM 07 WALL PT-01D BASE B-01/PT-01E FLOOR C-02
GB 10
7. G.C. TO SUBMIT SAMPLES OF ALL FINISHES FOR FINAL APPROVAL PRIOR TO ORDERING OF MATERIALS OR INSTALLATION.
15. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.
3
6
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
9' - 0" A.F.F. RESTROOM CLG
1' - 2"
8
1' - 6"
6. ALL CONCRETE FINISHES TO FOLLOW DESCRIPTION PROVIDED IN FINISH SCHEDULE
14. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES.
11
SCALE: 1/2" = 1'-0"
5. ALL INTERIOR GWB PAINT TO BE SPRAY APPLIED AND BACKROLL FINISHED. SAMPLE TO BE PROVIDED TO ARCHITECT FOR APPROVAL. G.C. AND F.C. TO COORDINATE AND MATCH PAINTED FINISHES.
A-306
15
RETAIL TENANT
ADA RESTROOM EAST
9' - 0" A.F.F. RESTROOM CLG
4. ALL FINISHING AND PAINTING REQUIREMENTS BE AS PER FINISH SCHEDULE, ELEVATIONS AND SPECIFICATIONS.
5
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
HOLD
0' - 0" A.F.F. FINISHED FLOOR
3. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP.
13. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS.
7
7' - 4"
6
SCALE: 1/2" = 1'-0"
2. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS.
12. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN FIRE-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.
HOLD
B-01 PT-01E
CASE ENGINEERING, INC.
DOOR
7
13
TPH
ADA RESTROOM NORTH
MEP ENGINEER
3' - 0"
9
SD TD
HOLD
1. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES.
PL.03
PL.01
1' - 2"
ENLARGED RESTROOM PLAN GENERAL NOTES:
11
7
12" CLEAR
TPH
0' - 0" A.F.F. FINISHED FLOOR
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
PL.01
1' - 0 7/8"
PARTITION TYPE TAG
7
GFI @ 46" AFF
18" CLEAR
FIXTURE TAG
PL.01
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
12 1
56" CLEAR
B-01 PT-01E
DOOR TO VESTIBULE EX-03
PL.02
2' - 4"
7
MR
PL.02
OWNER'S REPRESENTATIVE
1' - 0"
6' - 8"
10
8
15
MIN.
FINISH TAG
13
TD
3' - 6"
1
14
CAB ABV
10
PT-01E
HOLD
WHITE
GB
MIN.
PL.03
22 13
8
MIN
9
3' - 10 1/8"
3' - 0"
OCCUPANCY SENSOR/SWITCH
2' - 2"
8
3' - 0"
3' - 10"
OS
MR
14
6" HOLD
5' - 3"
FINISH ROOM TAG
1
TD
12
3' - 0"
HOLD
GB
6' - 11 1/8"
A
WALL MOUNTED 20A GFI GROUNDED DUPLEX WHITE RECEPTACLE W/ GROUND FAULT INTERRUPTER
12
PL.02
1' - 6"
X.01
RCP ROOM TAG
MR
HOLD
X-01
EXHAUST FAN & GRILLE
CAB
3' - 10"
WHITE
REF. MEP
SUPPLY GRILLE
HOLD 6"
(48" MAX)
WHITE
REF. MEP
7 1/4" PT-01E
3' - 7"
1
ARCHITECT
HOLD 7' - 4 1/8"
17
34" HOLD
WHITE
7' - 11 3/8"
PT-01D
CLEAR
CONCEALED SPRINKLER HEAD
1' - 4"
9"
1
17
4' - 6 1/8"
27" MIN.
WHITE
1' - 6"
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT AT 6'-8" AFF
6' - 8"
SMOKE DETECTOR CEILING MOUNTED
B.O. REFLECTIVE SURFACE
PARTITION BY TENANT'S G.C.
SD
PT-01D
1
40" MAX
FIRE ALARM STROBE WHITE CEILING MOUNTED
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT AT 6'-8" AFF
34" HOLD
ST CLG
6"
ROOM NAME 01 WALL WALL FINISH BASE BASE FINISH FLOOR FLOOR FINISH
QTY
PARTITION BY LANDLORD'S G.C.
CONCRETE FLOOR
ROOM NAME 01 TYPE FINISH 0'-0" AFF
FINISH
HOLD
SYMBOL DESCRIPTION
1' - 6"
DESCRIPTION
2' - 10"
HATCH / SYMBOL
9' - 0" A.F.F. RESTROOM CLG
48" CLEAR
9' - 0" A.F.F. RESTROOM CLG
RESTROOM SYMBOL / HATCH LEGEND
AREA: 1,400 SF
#
7' - 0"
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
4 A-306
1' - 4 1/4"
ENLARGED RESTROOM PLANS & ELEVATIONS 10
LL'S G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL
1
RESTROOM KEY PLAN SCALE: 1/8" = 1'-0"
A-306
CURTAIN RODS BY F.C.
4" X 3" X 30" L-BRACKET MT-01
2 1/2" HOLD 1 1/2"
1 1/2"
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A
7' - 4 1/2"
3' - 6" EQ
CURTAIN AND RINGS BY CURTAIN VENDOR; G.C TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM
2"
1 1/2"
3' - 6"
DASHED LINE INDICATES 3/4" FRT PLYWOOD IN-WALL BLOCKING
1 1/2"
EQ
1' - 0"
3' - 9"
2"
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A
1 1/2"
1 1/2"
HANG BAR BY F.C. SECURED TO FITTING ROOM PANEL BY G.C. MT-01
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A
4' - 2 1/2" HOLD 3' - 7"
2 1/2"
2 1/2"
CURTAIN AND CURTAIN RINGS BY CURTAIN VENDOR; G.C. TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
OWNER'S REPRESENTATIVE
1 1/2"
CURTAIN AND CURTAIN RINGS BY CURTAIN VENDOR; G.C. TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM 4' - 2 1/2"
ARCHITECT
4" X 3" X 30" LBRACKET MT-01
CURTAIN RODS BY F.C. FITTING ROOM HOOKS BY F.C.
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MT-01
A.05
A.04
6"
CASE ENGINEERING, INC.
EQ.
A.05
FREE-STADING FITTING ROOM FURNISHED BY F.C INSTALLED BY G.C.; G.C TO PROVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C
2 A-400
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH PT-01A 1' - 10 1/2"
HOLD
3' - 7 1/2"
1' - 10 1/2"
HOLD
HOLD
BONOBOS G.C. TO SECURE FITTING ROOM UNIT TO WALL WITH 3" x 4" x 30" PREDRILLED METAL BRACKETS MT-01 BY F.C.
2 1/2" HOLD
CONTINUOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C., REF. ELEVATIONS FOR LOCATIONS 7' - 7 1/2" A.F.F. T.O. FITTING ROOM UNIT STAMP
A.05
A.05
5"
A.04
PROVIDE WHIP CONNECTION FOR ALINEA LINEAR LIGHT FIXTURE; MOUNT 7'-2" AFF; FINISH WHIP TO MATCH ADJ. FINISH
5"
2' - 5"
MT-01
TYP.
7' - 2"
SCALE: 1" = 1'-0"
7' - 2" A.F.F.
V.I.F.
A.04
HANG BAR BY F.C. SECURED TO FITTING ROOM PANEL BY G.C.
BLACK LEVELERS
FITTING ROOM - SECTION W/ HOOKS
EQ.
5/8" TYPE 'X' GYP. BOARD
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
5' - 0" A-400
EQ.
CONTINUOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C., REF. ELEVATIONS FOR LOCATIONS
STRUCTURAL ENGINEER
6 A-400
1 1/2"
HOLD
1
4' - 2 1/2"
4" X 3" X 30" L-BRACKET MT-01
HOLD
7' - 7 1/2"
SCALE: 1" = 1'-0"
LICENSE # C-4550
OSBORN
TYP.
2
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
TM
1 A-400
3' - 10 1/2"
FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C. . INSTALLED BY G.C; G.C. TO RPOVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01
BLACK LEVELERS
FITTING ROOM - FRONT ELEVATION PRE-DRILLED L-ANGLE FOR WALL CONNECTION MT-01
WD-01
2 1/2" HOLD
SCALE: 1" = 1'-0"
F.22
4' - 0"
4
HOLD
7' - 6"
F.22
BLACK LEVELERS
FITTING ROOM - SECTION W/ HANGBAR
5' - 0"
5' - 0"
F.22
7' - 7 1/2"
WD-01
TYP.
7' - 2"
6' - 10"
HOLD
7' - 2"
WD-01
TYP.
5' - 0"
HOLD
HANG BAR BY F.C. SECURED TO FITTING ROOM PANEL BY G.C. MT-01
WD-01
7' - 6"
7' - 7 1/2"
A.04
6"
A.05
A.04
6
EQ.
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
EQ.
MEP ENGINEER
RETAIL TENANT
2' - 5"
F.22
TYP.
EQ.
FITTING ROOM HOOKS BY F.C. MT-01
C.L. OF LINEAR LIGHT
A-400
EQ.
WD-01
5
EQ.
PARTITION AS SCHEDULED; REF. A-100 & A-600 FOR PARTITION TYPE AND SCHEDULE.
F.22
1 1/2"
FB.01
3' - 6"
F.22
1 1/2"
CLEAR
3' - 6"
1 1/2"
CLEAR
2"
7' - 4 1/2"
HOLD
HOLD
FITTING ROOM UNIT BY F.C. WD-01 MT-01
FB.01
CURTAIN AND RINGS BY CURTAIN VENDOR
WALL BASE AS SCHEDULED; REF. A-104 & A-600 FOR LOCATION AND DETAILS.
BLACK LEVELERS FINISHED FLOOR AS SCHEDULED; REF. A-104
FREE-STANDING FITTING ROOM (F.22) FURNISHED BY F.C. . INSTALLED BY G.C; G.C. TO RPOVIDE 3/4" FRT PLYWOOD IN-WALL BLOCKING BY G.C BLACK METAL FRAME TO MATCH MT-01 WOOD PANELS TO MATCH WD-01
5
FITTING ROOM - SIDE ELEVATION SCALE: 1" = 1'-0"
DATE: 02/27/2019 DRAWN BY: RA, NK AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
FINISHED FLOOR
FREE-STANDING FITTING ROOM DETAILS
BLACK LEVELERS
3
FITTING ROOM - PLAN SCALE: 1" = 1'-0"
DATE 02/27/2019 03/04/2019
0' - 0" A.F.F.
CURTAIN AND CURTAIN RINGS BY CURTAIN VENDOR; G.C. TO INSTALL ON ROD PRIOR TO ASSEMBLY OF F.22 FREE-STANDING FITTING ROOM F.22
PROJECT NO.: 218259
CHECKED BY: JSP
4 A-400
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
1
FITTTING ROOM UNIT OFFSTAND DETAIL SCALE: 3" = 1'-0"
A-400
ARCHITECT
DUCT BEYOND; REF. MEP DRAWINGS PLENUM BOX BEYOND; REF. MEP DRAWINGS
EXISTING STRUCTURE ABOVE TO REMAIN; G.C. TO ENSURE MAINTENANCE OF FIRE-RATING AND FIRE-PROTECTION
12 GAUGE HANGER WIRE SUPPORT DIFFUSER AND PLENUM BOX FROM STRUCTURE ABOVE
3 5/8" 18 GA. METAL STUD BRACING TO STRUCTURE AT 4'-0" O.C. MAX, ALTERNATING SIDES, LENGTH OF BRACING MAY NOT EXCEED 16'-0"
5/8"THK TYPE 'X' GYP. BOARD
LIGHT SHIELD CONTINUOUS ALONG SLOT EXCEPT AT ACTIVE PLENUM BOX LOCATIONS
3 5/8" 18 GA. METAL STUD BRACING TO STRUCTURE AT 4'-0" O.C. MAX, ALTERNATING SIDES, LENGTH OF BRACING MAY NOT EXCEED 16'-0"
SUSPENDED CEILING SYSTEM HARD CEILING ATTACHMENT CLIPS
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
OWNER'S REPRESENTATIVE
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
5/8"THK TYPE 'X' GYP. BOARD AT CEILING
4" x 4" x 20 GA. CLIP ANGLE, FASTEN TO EACH BRACE AND RUNNER WITH TEK SCREWS (3 PER LEG, TYP)
REF. RCP B.O. CEILING
10" HOLD
1"
1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS; TAPE AND SAND PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED
SLOT
12
METAL STUD FRAMING AS SCHEDULED; SEE CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600
TAPED-IN LINEAR SLOT DETAIL
CASE ENGINEERING, INC.
4 x 2" TEK SCREWS AT EACH BOTTOM FLANGE
DRYWALL CORNER BEAD
8
SCALE: 3" = 1'-0"
MEP ENGINEER
METAL TRACK AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600
TYP. GYP. BOARD CORNER SCALE: N.T.S.
4" x 4" x 20 GA. CLIP ANGLE AT EACH BRACE
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550
3
TYP. BRACING AT STRUCTURE
STRUCTURAL ENGINEER
SCALE: N.T.S. TM
2"THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF EXISTING RATED CEILING AS REQ'D
1 LAYER OF 5/8" TYPE 'X' GYP. BOARD; REF. FINISH PLAN FOR WALL FINISH
6" MIN.
BLOCKING AS REQ'D 5/8" TYPE "X" GYP. BOARD PT-01A
MOUNTING RAIL BETWEEN 6" METAL STUDS; REFER TO FIXTURE CUT SHEET
CURTAIN CARRIER PROVIDED BY VENDOR, FOREST CS TRACK 25010, 0.8" x 0.8"; FINISH WHITE
13/16"
NOT USED
CEILING AS SCHEDULED; REF. RCP A-102 METAL STUD FRAMING AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600
7' - 0" A.F.F. B.O. OPENING SHIM AS REQUIRED
EXISTING 6" METAL STUDS SPACED AT 16" O.C. TO REMAIN
EQ
RECESSED EM LIGHT DETAIL AT 1-HR RATED WALL
CURTAIN FABRIC PROVIDED BY VENDOR WITH CS STOP CARRIER 25102 FB-01
PARTITION THICKNESS
7
SCALE: 3" = 1'-0"
EQ
REF. PLAN
FIRESTOPPING AS REQUIRED
RECESSED DRAPERY TRACK DETAIL SCALE: 6" = 1'-0"
ATTACHMENT TO STRUCTURAL SUPPORT TO COMPLY W/ LOCAL CODE
45°
45°
12 GA. VERTICAL HANGER WIRE AT 4' - 0" O.C. EACH WAY AND 8" MAX FROM ALL PERIMETER EDGES
2" MAX 45°
2" MAX
NOT USED
45°
45°
SUSPENSION CROSS TEES SPACED AT 2' - 0" O.C. MAX.
45° 45°
2" MAX 2" MAX
6
SCALE: N.T.S.
3 A-500
SUSPENSION CROSS TEES SPACED AT 2' - 0" O.C. MAX.
5/8"THK TYPE 'X' GYP. BD. W/ FINISH AS SCHEDULED; REF. FINISH PLAN A-104 2 A-500
DRYWALL SUSPENSION TEES
4' - 0" O.C., TYP.
AT PERIMETER 5/8"THK TYPE 'X' GYP. BOARD 2" MIN WALL ANGLE MOLDING; GRID MEMBERS ATTACHED TO WALL MOLDING @ 2 ADJACENT WALLS USING POP RIVETS OR SCREWS
NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05
SCALE: N.T.S.
STAMP
4. ALL STUDS SHALL BE ''C' TYPE WITH FLANGE STIFFENERS 5. THE MATERIALS AND DETAILS SHOWN ARE FOR TYPICAL INSTALLATION. WHERE THE MANUFACTURER RECOMMENDS OR LOCAL ORDINANCES AND/OR CODES ARE MORE RESTRICTIVE, THE HIGHER STANDARD SHALL PREVAIL AND APPLY \
TYPICAL FASTENERS: 1. STEEL STUDS TO STEEL STUDS OR TRACKS: #8-18 x 1/2" TEKS/2 W/ PHIL PAN-HEAD FOR 25 GA. OR 20 GA. #10-16 x 9/16" TEKS/3 W/ PHIL PAN-HEAD FOR INTERCONNECTION OF 18 GA. OR 16 GA.
WALL BASE AS SCHEDULED; REF. FINISH PLAN
3. STEEL STUDS OR TRACKS TO STRUCTURAL STEEL (WIDE FLANGE BEAMS, COLUMNS, GIRDERS, STEEL TUBE SHAPES E.T.C.): TEKS/3 OR TEKS/4 GA. AND LENGTH AS REQ'D FOR THE COMBINED THICKNESS OF THE MATERIAL TO BE DRILLED 4. PLYWOOD TO STEEL STUDS: #10-24 x 3/4" TEKS/3 (PLYMETAL TEKS) WITH THIN WAFER HEAD 5. GYPSUM BOARD TO STEEL STUDS: #7 x 1/4" TYPE 'S' BUGLE HEADS SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 25 GA. OR 20 GA. METAL STUDS #6 x 1/2" TYPE 'S' BUGLE HEADS SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 18 GA. OR 16 GA. METAL STUDS
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: RA, NK CHECKED BY: JSP AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
EXISTING FLOOR SLAB
ACOUSTIC / FIRE CAULKING AS REQ'D
FASTEN WALL ANGLE TO SUSPENSION TEES
9
HORZ. BRIDGING TYP.
2" WALL ANGLE
SUSPENSION CROSS TEES SPACED AT 2' - 0" O.C. MAX.
3. ALL STUD WALLS AND PARTITIONS SHALL HAVE CONTINUOUS LINES OF BRIDGING SPACED AT 4'-0" O.C. THE BRIDGING SHALL BE SECURELY FASTENED TO THE STUDS WITH EITHER WELDS OR SCREWS
2. STEEL STUDS OR TRACKS TO WOOD PURLINS, GIRDERS, AND BEAMS #14-10 x 1/2" H.W.H. TYPE 'S' METAL-TO-WOOD TEKS
8" MAX
SUSPENSION MAIN TEES SPACED AT 4' - 0" O.C. MAX.
TYP. SUSPENDED GYP. BOARD CEILING
METAL STUD FRAMING AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600
4 A-500
12 GAUGE HANGER WIRE
FASTEN WALL ANGLE TO WALL FRAMING, TYP.
2 1/2" x 18 GA 3 5/8" x 18 GA 6" x 18 GA 6" x 18 GA
6. G.C. TO COORDINATE ANY AND ALL REQUIRED SPECIAL INSPECTIONS OF CEILING AND PARTITION FRAMING WITH LOCAL CODE OFFICIAL
NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05
SCALE: N.T.S.
MINIMUM OF 3 TIGHT TURNS AT ALL WIRES.
2 1/2" x 18 GA 3 5/8" x 18 GA 6" x 18 GA 6" x 18 GA
TOP TRACK 8' - 0" SPAN 11' - 0" SPAN 2 1/2" x 18 GA NOT APPLICABLE 3 5/8" x 18 GA 3 5/8" x 18 GA DL 6" x 18 GA 6" x 18 GA 6" x 18 GA 6" x 18 GA DL
2. ALL SUSPENDED WALLS SHALL HAVE GYPSUM BOARD THAT EXTENDS AT LEAST 6" ABOVE THE SUSPEND CEILING (UNLESS SPECIFICALLY DETAILED OTHERWISE)
3 5/8" 18 GA. METAL STUD BRACING TO STRUCTURE AT 4'-0" O.C. MAX, ALTERNATING SIDES, LENGTH OF BRACING MAY NOT EXCEED 16'-0"
TYP. COMPRESSION STRUT SUSPENSION
12 GA VERTICAL HANGER WIRE @ 4' - 0" O.C. EACH WAY. AND 8" MAX FROM ALL PERIMETER EDGES.
AS NOTED UP TO 16' - 0" 16' - 0" TO 20'-0" 20' - 0" TO 24'-0"
BOTTOM TRACK
1. ALL LIGHT GA. METAL STUD WALLS AND PARTITIONS REQUIRE 5/8"THK TYPE 'X' GYPSUM BOARD ON BOTH SIDES FOR THE FULL HEIGHT OF THE STUDS (UNLESS SPECIFICALLY DETAILED OTHERWISE
TYPICAL 12 GA. HANGER WIRE SPACED AT 4'-0" O.C. MAX.
NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05
TYP. COMPRESSION STRUT CEILING ATTACHMENT
8" MAX
SUSPENSION MAIN TEES SPACED AT 4' - 0" O.C. MAX.
SCALE: N.T.S.
PARTITION FRAMING SCHEDULE NOTES:
(4) SPLAY WIRES AT 45° PARALLEL TO CROSS TEES
NOTE: MECHANICAL EQUIPMENT AND LIGHT FIXTURES MUST BE CONNECTED TO ONE (1) VERTICAL 12 GA. WIRE ATTACHED TO OPPOSING CORNERS ALONG THE FIXTURE'S DIAGONAL. THESE WIRES MAY BE SLACK (UBC STD. NO 25.213.25214
10
EXISTING STRUCTURE ABOVE TO REMAIN; G.C. TO ENSURE MAINTENANCE OF FIRE-RATING AND FIRE-PROTECTION
HORIZONTALLY
5/8"THK TYPE 'X' GYP BOARD
NOT USED
TYP. HORZ. BRIDGING
HEIGHT
(4) SPLAY WIRES AT 45° PARALLEL TO CROSS TEES
SUSPENSION MAIN TEES SPACED AT 4' - 0" O.C. MAX.
3/4" THIN WALL ELEC. CONDUIT W./ SLOT AT END TO FIT OVER CEILING RUNNER
2
PARTITION FRAMING SCHEDULE:
12 GA. VERTICAL HANGER WIRE WITHIN TUBING, LEVEL CEILING PRIOR TO SETTING STRUT COMPRESSION STRUT SPACED AT 12'-0" O.C. MAX.
DRILL 3/32" HOLE AND INSTALL 1/8"Ø BOLT AND LOCKING NUT
45°
SCALE: N.T.S.
ANGLE CLIP PINNED AND BOLTED TO COMPRESSION STRUT
12 GA. VERTICAL HANGER WIRE WITHIN TUBING, LEVEL CEILING PRIOR TO SETTING STRUT
4" MIN.
INSTALL COMPRESSION STRUT IN COMPLIANCE WITH LOCAL CODE, STRUTS TO BE 12' - 0" O.C. EACH DIRECTION
TYP. BRACING AT PARTITION
MIN.
1/2"Ø THIN WALL ELEC. CONDUIT OR APPROVED EQUIVALENT (EXTEND TUBE TO BE TIGHT TO SUSPENDED CEILING & STRUCTURE ABOVE, THEN INSTALL BOLT TO SECURE IN PLACE)
4
6"
11
13/16"
METAL STUD FRAMING AS SCHEDULED; REF. CONSTRUCTION PLAN A-100 AND PARTITION DETAILS A-600
5/8"THK TYPE 'X' GYP. BOARD W/ FINISH AS SCHEDULED; REF. FINISH PLAN A-104
5/8" TYPE "X" GYP. BOARD PT-01A
1 LAYER OF 5/8" TYPE 'X' GYP. BOARD; G.C. TO PROVIDE FIRE CAULKING AS REQ'D TO MAINTAIN 1HR FIRE RATING
3/4" 16 GA. COLDROLLED CHANNEL SPACED AT 4'-0" O.C. HORIZONTALLY
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
3 5/8" METAL STUD FRAMING
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
RETAIL TENANT
FLUSH MOUNTED EMERGENCY LIGHT; PAINT TO MATCH ADJ FINISH, REF. FINISH PLAN
OSBORN
1 1/2" x 3" 16 GA. CHANNEL CLIP ANGLE, FASTEN TO STUD AND CHANNEL W/ (4) 5/8" #5 TEK SCREWS ALT. FASTENING (3) 3/4" WELDS (AT 3 DIFFERENT PLACES)
2" MIN WALL ANGLE
5
CAULK WHERE WALL ANGLE MEETS WALL J-BEAD AT ALL GYP. BOARD CEILING EDGES
NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05
TYP. SUSPENDED CEILING T PERIMETER SCALE: N.T.S.
CONTINUOUS BOTTOM TRACK W/ 'HILTI' PNEUMATIC SHOT PINS .145Ø W/ DISCS @ 16" O.C. TYP.
1
TYP. BRACED PARTITION SCALE: N.T.S.
CONSTRUCTION & CEILING DETAILS
A-500
PAINTED WOOD BASE. REF. A-104; FINISH TO MATCH B-01 PT-01B
HOLD
EQ
PAINTED WOOD BASE. FINISH TO MATCH B-01 PT-01B
EQ
4' - 5" HOLD
1' - 2 1/2"
3' - 2 1/2" 11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. EXTEND TO UNDERSIDE OF DECK
1' - 4 5/8" VIF
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. BEYOND
A
2' - 5"
EXISTING CONCRETE COLUMN. REF. STRUCTURAL DWGS
5/8" TYPE "X" GYP. BOARD.
10
OWNER'S REPRESENTATIVE
1' - 4 5/8"
1 3/4"
1' - 4 5/8"
5/8" 1 7/8"
ARCHITECT
B
ALIGN FACE OF GYP. BOARD W/ COLUMN 'A' AT STOREFORNT BEYOND
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
5/8" TYPE "X" GYP. BOARD.
FIRE RATED WOOD BLOCKING AS REQ'D.
10
EXISTING CONCRETE COLUMN. REF. STRUCTURAL DWGS
FIRE RATED WOOD BLOCKING AS REQ'D.
2 x 12 DECORATIVE BEAM; COORD. EXTENTS W/ RCP, FINISH TO MATCH WD-02
12
12' - 8 1/4" A.F.F.
4' - 10"
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. EXTEND TO UNDERSIDE OF DECK
COLUMN B DETAIL
HOLD
CASE ENGINEERING, INC. 3' - 9"
EXISTING CONCRETE BEAM TO REMAIN
MEP ENGINEER
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
LICENSE # C-4550
2' - 4 3/8"
PT-02
HOLD
BLOCKING AS REQUIRED
SCALE: 1 1/2" = 1'-0"
STRUCTURAL ENGINEER
TM
T.O. BEAM
3' - 5 3/8"
OSBORN
WD-02
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C.
BLOCKING AS REQUIRED
(1) LAYER 5/8" TYPE 'X' GYP. BOARD EXTENDED TO STRUCTURE ABOVE ON METAL FRAMING. G.C. TO PAINT PT-02 ABOVE 11-9" AFF PAINT LINE; G.C. TO PAINT PT-01A BELOW PAINT LINE
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. BEYOND
PT-01A
1 1/2"
5/8" TYP. 'X' GYP. BOARD BY G.C. AS REQ'D TO INSTLALL CONCEALED IN-WALL BLOCKING
NEW 2 X 12 DECORATIVE BEAMS; COORD. EXTENTS W/ RCP WD-02
5
DECORATIVE BEAM - WALL CONNECTION @ ENTRY
3
SCALE: 3" = 1'-0"
CONCELAED FASTENING OF WOOD BEAM TO WALL BLOCKING
DECORATIVE BEAM - WALL CONNECTION SCALE: 3" = 1'-0"
2
COLUMN A DETAIL SCALE: 1 1/2" = 1'-0"
19' - 9" V.I.F.
19' - 9" V.I.F.
B.O. EXISTING SLAB
B.O. EXISTING SLAB UNDERSIDE OF EXISTING SLAB
5 A-501
2 x 12 DECORATIVE BEAM; COORD. EXTENTS W/ RCP, FINISH TO MATCH WD-02
UNDERSIDE OF EXISTING SLAB
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EXTENDED TO STRUCTURE ABOVE ON METAL FRAMING (BEAM SIDE ONLY) G.C. TO PAINT WALL ABOVE PAINT LINE AT B.O. BEAM PT-02
PT-02
STAMP
PT-02
3"
3"
3"
PT-02 AT BEAM ENDS THIS SIDE ONLY 5"
EQ
A-501
LED TAPE LIGHTING (T-01) WITH ANGLE CHANNEL (TLACA6), CLIP MOUNTED ON PAINT GRADE PLYWOOD; G.C. TO INSTALL TAPE LIGHT IN 3 EQUAL SECTIONS; REF. RCP
(4) 1/2" Ã&#x2DC; THRU BOLTS AND NUT WITH WASHERS AT EACH SIDE. POWDER-COATED TO MATCH 3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. EXTEND TO UNDERSIDE OF DECK
HOLD
PT-02
3/4" PAINT GRADE PLYWOOD PT-01C
CONTINUOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING
11' - 9" A.F.F.
1 3/8" HOLD
HOLD
SALES CEILING
SCALE: 3" = 1'-0"
AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
11' - 0" A.F.F. (1) LAYER 5/8" THK 'X' TYPE GYP. BOARD PT-01C
8" HOLD
DATE: 02/27/2019 DRAWN BY: NK, JO
11' - 0" A.F.F.
PT-01C
PROJECT NO.: 218259
CHECKED BY: JSP
BLOCKING AS REQUIRED
WOOD BLOCKING AS REQ'D
SECTION AT DECORATIVE BEAM
T.O WALL WASHER COVE
8"
9"
11' - 8" A.F.F.
EQ.
6" METAL STUD CEILING FRAMING SPACED AT 24" O.C.; BRACE TO DECK AS REQ'D
PT-01A
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
6" METAL STUD CEILING FRAMING SPACED AT 24" O.C.; BRACE TO DECK AS REQ'D
B.O. BEAM & PAINT LINE
EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRE-RATED AND WHERE DAMAGED PATCH AND RESEAL AS REQ'D TO RESTORE RATING
7 3/8"
4"
3
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C EXTEND TO UNDERSIDE OF DECK
FASTEN HANGER TO GYP. BOARD AND BLOCKING WITH BLACK SCREWS
WD-02
11 1/4"
WD-02
(1) LAYER FOR 5/8" TYPE 'X' GYP. BOARD EXTENDED TO STRUCTURE ABOVE ON METAL FRAMING AT EACH SIDE OF STUD, REF. A-100 & A-600 FOR PARTITION TYPE AND SCHEDULE. PAINT PT-02 ABOVE 11-9" AFF PAINT LINE; G.C. TO PAINT BELOW PAINT LINE
JOIST HANGER AT CONCEALED END OF DECORATIVE BEAM ONLY. POWDER-COATED TO MATCH PT-02
HOLD
3"
CONCEAL FASTENING OF WOOD BEAM TO WALL BLOCKING
T.O. BEAM
4"
EQ EQ
EQ.
EQ
12' - 8 1/4" A.F.F.
CONTINOUS 3/4" FRT PLYWOOD IN-WALL BLOCKING
4
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
B.O. BEAM & PAINT LINE
RETAIL TENANT
EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRE-RATED AND WHERE DAMAGED PATCH AND RE-SEAL AS REQ'D TO RESTORE RATING
3/4"
11' - 9" A.F.F.
EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRE-RATED AND WHERE DAMAGED PATCH AND RE-SEAL AS REQ'D TO RESTORE RATING
V.I.F.
3/4" THK CONTINUOUS FRT PLYWOOD BLOCKING BY G.C.
5/8" TYPE "X" GYP. BOARD;
1' - 1"
CONTINUOUS 3/8" FRT PLYWOOD IN-WALL BLOCKING
ALIGN
SALES CEILING
6" HOLD
5/8"THK TYPE 'X' GYP. BOARD PT-01C
EXISTING 1-HR RATED DEMISING WALL BY LANDLORD; G.C. TO MAINTAIN FIRERATED AND WHERE DAMAGED PATCH AND RE-SEAL AS REQ'D TO RESTORE RATING; G.C. TO PAINT PT-01A
1
WALL WASHER CEILING DETAIL SCALE: 3" = 1'-0"
CONSTRUCTION & CEILING DETAILS
A-501
ARCHITECT
13' - 6 3/4" A.F.F. T.O. EXISITNG PARAPET
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
12' - 3" A.F.F. ROOF
OWNER'S REPRESENTATIVE
EXIST. CONCRETE BEAM AND ROOF, SEE STRUCTURAL DWGS.
11' - 9" A.F.F. B.O. BEAMS
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
G.C. TO PROVIDE CONTINUOUS FIRE CAULKING AT TOP, BOTTOM AND EDGES OF PARTITION AT BOTH SIDES AND ALL PENETRATIONS 11' - 0" A.F.F. STOREFRONT LOUNGE ENTRY SALES DISPLAY CEILING
CASE ENGINEERING, INC.
3 5/8" METAL FRAMING BY G.C.
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
5/8" TYPE " X" GYP. BOARD 1 5/8" METAL FRAMING BY G.C. 17 A-502
3 1/2" METAL STUD FRAMING SPACED AT 16" O.C.
EXISTING DEMISING WALL BEYOND
3/4" TYPE " X" GYP. BOARD ALIGN
11' - 5" A.F.F.
EXISTING LANDLORD STRUCTURAL BEAM; REF. LANDLORD STRUCTURAL DWGS
T.O. LIGHT COVE
11' - 0" A.F.F. STOREFRONT DISPLAY CEILING
1 5/8"
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C.
10' - 11" A.F.F. T.O. STOREFRONT
5"
3"
1" 1 1/2"
5/8" TYPE " X" GYP. BOARD AT CEILING, TYP.
2"
SECTION DETAIL - DEMISE ABOVE ENTRY
2
SCALE: 1 1/2" = 1'-0"
LEASE LINE
ARAKAWA MERCHANDISING TRACKS MODEL CRB 1800A, RECESSED INTO GWB CEILING, POWDERCOATED TO MATCH ADJ. FINISH PT-01C ; G.C. TO TAPE AND MUD ALL GYP. BOARD EDGES PRIOR TO INSTALLING; G.C. TO ENSURE NEAT INSTALL OF ARAKAWA TRACKS AND PATCH ANY AND ALL ROUGH GYP. EDGES AS REQUIRED
UL263: 1-HR RATED ALT. DEMISING PARTITION
4
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
TRACK LIGHT HEAD; REF. RCP
8' - 2" A.F.F. B.O. ENTRY SOFFIT VIF
3/4" FRT PLYWOOD BLOCKING ABOVE CEILING AT ARAKAWA TRACKS AND LIGHT COVE
5"
OSBORN
EXIST. COMPOSITE METAL PANEL TO REMAIN
HOLD
5"
FRT BLOCKING AS REQ'D
FRT BLOCKING AS REQ'D
ALIGN
TM
5/8" TYPE " X" GYP. BOARD AT LIGHT COVE, TYP. PT-01C
5/8" TYPE 'X' GYP. BOARD
EXISTING LANDLORD STOREFRONT SYSTEM TO REMAIN
STRUCTURAL ENGINEER
3/4" FRT PLYWOOD BLOCKING ABOVE CEILING AT ARAKAWA TRACKS AND LIGHT COVE
EXISTING LANDLORD ENTRY SOFFIT TO REMAIN
ALIGN GYP. W/ TOP OF MULLION
LICENSE # C-4550
6"
6"
4"
8"
3 1/8"
HOLD
HOLD
HOLD
HOLD
VIF
5"
2 1/2"
STOREFRONT LIGHT COVE DETAILS SCALE: 3" = 1'-0"
NEW WOOD VENEER DISPLAY PLATFORM AT INTERIOR DISPLAY WINDOWS BY F.C.. FINISH TO MATCH WD-01
2' - 3 13/16" VIF 2' - 3 1/16" PLATFORM
4
ALIGN
EXISTING 25 MILL MEMBRANE FLASHING, CONTINUOUS INTO ROUGH OPENING 1' - 6" A.F.F. KNEE WALL
STAMP
ALIGN
V.I.F
DEMISING WALL W/ 6" METAL FRAMING BY LANDLORD
EXISTING LANDLORD STOREFRONT SYSTEM TO REMAIN
1' - 5 1/4"
EXISTING LANDLORD ENTRY SOFFIT TO REMAIN
VIF
1' - 6" DISPLAY PLATFORM
2' - 6"
LEASE LINE
3 3/8"
5"
1 1/8"
2"
3 1/8"
1 9/16"
1 9/16"
GYP. BOARD LEDGE BELOW
ALIGN 1 5/8" 3 3/8"
ALIGN
ALIGN EDGE OF PLATFORM WITH EXISTING STOREFRONT BEYOND
3/4" TYPE " X" GYP. BOARD
7/8"
3/4" REVEAL EXISTING STOREFRONT
1 5/8" METAL FRAMING BY G.C. SPACED AT 16" O.C., TYP.
7 1/4"
2 3/16" VIF
A-502
FRT BLOCKING AS REQ'D
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
3 1/8"
RETAIL TENANT
5"
MEP ENGINEER
EXISTING STOREFRONT KNEE WALL 5/8" TYPE "X" GYP. BOARD. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
5/8" TYPE " X" GYP. BOARD EXISTING 1-HR RATED DEMISING WALL
3/4" REVEAL
PROJECT NO.: 218259 DATE: 02/27/2019 DRAWN BY: Author CHECKED BY: Checker 0' - 0" A.F.F. FINISHED FLOOR 3/4" REVEAL PREFINISHED BY F.C. TO MATCH PT-05
AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
CONSTRUCTION DETAILS AT STOREFRONT
3
ENLARGED PLAN - DEMISE ABOVE ENTRY SCALE: 1 1/2" = 1'-0"
1
DISPLAY PLATFORM SECTION SCALE: 3" = 1'-0"
A-502
ARCHITECT
19' - 9" A.F.F.
19' - 9" A.F.F. B.O. EXISTING SLAB UNDERSIDE OF EXISTING SLAB
UNDERSIDE OF EXISTING SLAB BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP
CONTINUOUS METAL TRACK
CONTINUOUS METAL TRACK
CONTINUOUS METAL TRACK
CONTINUOUS METAL TRACK
NEW FINISHED FLOOR AS SCHEDULED
NEW FINISHED FLOOR AS SCHEDULED
NEW FINISHED FLOOR AS SCHEDULED
NEW FINISHED FLOOR AS SCHEDULED
6" METAL STUD, SPACED AT 16" O.C. TYP
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP
NEW FINISHED FLOOR AS SCHEDULED
7 1/4"
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY
0' - 0" A.F.F.
FINISHED FLOOR
FINISHED FLOOR
NOTE: BASE AS SCHEDULED
4 7/8"
NOTE: BASE AS SCHEDULED
4 1/4"
NOTE: BASE AS SCHEDULED
4 7/8"
NOTE: BASE AS SCHEDULED
2 1/2" VERTICAL METAL 'Z' FURRING AT 24" O.C.
PAINT EXTERIOR TO MATCH EXISTING (1) LAYER 5/8" TYPE 'X' GYP. BOARD
NOT USED
2 HR RATED 8" CMU
OWNER'S REPRESENTATIVE
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER
1 1/4" POLYISSOCYANURATE FOAM SHEATHING, R-7.6
CASE ENGINEERING, INC.
NEW FINISHED FLOOR AS SCHEDULED
796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
0' - 0" A.F.F.
NOTE: BASE AS SCHEDULED
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
T.O. EX'G LANDLORD DOOR
T.O. PARTIAL HEIGHT WALL
0' - 0" A.F.F.
4 1/4"
7' 2" V.I.F
9' - 0" A.F.F.
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE; EXTEND GYP. BOARD TO DECK ABOVE AT LOCATION'S WITH NO CEILING, TYP.; REF. RCP
CONTINUOUS METAL TRACK
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD AT TOP; FINISH TO MATCH ADJ. WALL FINISH PT-01C
. 6"
6" .
6"
BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES
EXISTING LANDLORD CMU WALL ALIGN
B.O. EXISTING SLAB UNDERSIDE OF EXISTING SLAB
LICENSE # C-4550
FINISHED FLOOR STRUCTURAL ENGINEER
NOTE: BASE AS SCHEDULED
10 3/4"
TM
OSBORN ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS. G.C TO PROVIDE 3 5/8" 20 GAUGE METAL STUD IN LIEU OF 6" METAL STUD PROVIDE WALL BASE AS SCHEDULED REF. A-104 FINISH PLAN
C
•
•
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN
PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN
D
•
•
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS EXTEND GYP. BOARD 6" ABOVE CEILING
E
WALL TYPE "E" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT • •
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
F
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD PROVIDE GYP. BOARD AT TOP OF PARTIAL HEIGHT PARTITION AND FINISH TOP OF PARTITION TO MATCH WALL FINISH USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS
WALL TYPE "F" - INTERIOR NON-LOAD BEARING PARTITION - CMU INFILL
REFERENCE UL-U905 • •
2 HOUR RATED 8" CMU WALL WITH 'Z' FURRING ON INTERIOR SIDE, REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD AT ONE SIDE ONLY; INSTALL GYP. BOARD AT TENANT SIDE ONLY AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN
PROVIDE WALL BASE AS SCHEDULED REF. A-104 FINISH PLAN
PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN
PARTITION TYPES SCALE: 1 1/2" = 1'-0"
3/8"
3/4" 3/8" REF. A-100 FOR PARTITION TYPE
BOH
2"
SCRIBE
7/8"
EXISTING CONCRETE FLOOR WITH NEW POLISHED FINISH AS SCHEDULED; REF. A-104 C-04
B-01
PAINTED WOOD TRIM FOR DOOR CASING BY F.C. REFER TO DOOR HEAD AND JAMB DETAILS A-601
TRIM PROFILES
2
SCALE: 6" = 1'-0"
1/4"
EXISTING SLOPED SIDEWALK
SLOPE 1:48 MAX.
EXISTING CONCRETE FLOOR TO REMAIN, G.C TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR; REF. A-104 C-02
EXISTING CONCRETE SLAB ON GRADE, G.C. TO ENSURE LEVEL SURFACE FOR APPLICATION OF NEW FLOOR FINISH
REF. A-100 FOR PARTITION TYPE
PROJECT NO.: 218259
PAINTED WOOD BASE SCRIBE BASE TO FLOOR B-01 PT-01B
DATE: 02/27/2019 DRAWN BY: RA, NK
3/4" SALES
CHECKED BY: JSP AREA: 1,400 SF
# EXISTING CONCRETE FLOOR TO REMAIN, G.C TO PREP FLOOR PER VENDOR RECOMMENDATIONS FOR NEW CUSTOM STAIN COLOR; REF. A-104 C-02
1
B-01 WALL BASE 01 SCALE: 3" = 1'-0"
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
4"
LEASE LINE
SCALE: 3" = 1'-0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
1"
NEW REMOVABLE 3/8" THICK WALKOFF MAT BY RETAIL TENANT' G.C. CPT-02
THRESHOLD 'A'
SCALE: 3" = 1'-0"
5"
EXISTING ENTRY DOOR
G.C. TO CONFIRM EXISTING THRESHOLD IS ADA COMPLIANT AND REPLACE IF REQ'D W/ PEMKO ADA COMPLIANT THRESHOLD
B-02 WALL BASE 02
INTERIOR (PUSH SIDE)
EXTERIOR (PULL SIDE)
3
STAMP
TR-01
PAINTED WOOD TRIM FOR WALL BASE BY G.C.
4
4"
3 5/8"
4"
4" TALL RUBBER WALL BASE, SCARIFY SURFACE BEHIND BASE ONLY PRIOR TO INSTALLATION B-02
1"
5
•
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK
WALL TYPE "D" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
•
6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS
•
WALL TYPE "C" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT
RETAIL TENANT
•
B
WALL TYPE "B" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT
5"
A
WALL TYPE "A" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT
PARTITION, TRIM, & THRESHOLD DETAILS
A-600
ARCHITECT
6" METAL FRAMING
2" 1/4"
3 5/8" DOUBLE METAL STUD LINTEL
3' - 0"
1/8"
DOOR
2"
15 W 37th Street 15th Floor New York, NY 10018 P: (212) 279-2670 F: (212) 279-2671
7' - 0"
MEP ENGINEER
CASE ENGINEERING, INC. 796 Merus Court St. Louis, MO 63026 P: (636) 349-1600 F: (636) 349-1730
5' - 0"
LICENSE # C-4550
3' - 0"
G.C. TO PROVIDE MIRROR; CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC GL-02
STRUCTURAL ENGINEER
5/8"
3/8"
DOOR 7' - 0 3/4"
PT-01E
7' - 7 1/2"
DOOR
7' - 7 1/8"
PT-01E
6' - 10 1/8"
OWNER'S REPRESENTATIVE
1/8"
4 1/2"
1/16"
3' - 0"
MIRROR V.I.F.
EQ
3"
EQ
11881 North 113 Way Scottsdale, AZ 85259 phone: (480) 614-3385 fax: (480) 614-0209 email: davidaudkow@cox.net
2" PAINTED HOLLOW METAL DOOR FRAME PT-01E
1/4"
2"
1/8"
2"
GL-02
DEADLOCK BY F.C.; THUMBTURN AT BOH SIDE
3"
3' - 0 1/4"
9"
4 1/2"
5/8"
WD-01
SALES (PUSH)
KICK PLATE, AT PULL SIDE ONLY REF. DOOR HARDWARE SCHEDULE
1/16"
1/4" 2"
2" 1/8"
1/4"
B.O.H./RESTROOM (PULL)
SALES (PULL)
2" ADA RESTROOM SIGNAGE, G.C. TO INSTALL PER LOCAL CODE REQUIREMENTS
MIRROR VIF
SHIM AS REQ'D
HOLLOW METAL DOOR ; PT-01E
3/8"
KICK PLATE, BY F.C. REF. DOOR HARDWARE SCHEDULE
1/4" MIRROR, BY G.C. GL-02
1/16"
2' - 2 7/8"
3' - 0"
4 1/2"
B.O.H. (PUSH)
7'-7 3/4" DOOR OPENING
1/4"
WOOD VENEER W/ MDF CORE DOOR, BY F.C. WD-01
1/16" 1/16" MAX. MAX. 7' - 7 1/8" DOOR
1 1/4" 1 7/8"
4 1/2"
4 1/8"
7/8" x 2" PAINTED WOOD TRIM BY F.C. TR-01 PT-01B
4 1/2"
2' - 3"
1/16"
MOUNT CLOSER AT RESTROOM SIDE, W/ HOLD OPEN
1/4"
3 5/8" METAL TRACKS
HOLLOW METAL DOOR FRAME PT-01E
1"
1/2" x 1 1/4" PAINTED WOOD DOOR STOP, BY F.C. PT-01B
4 1/2"
3 5/8" DOUBLE METAL STUD LINTEL
2"
7/8"
3' - 0"
6' - 10"
7/8" X 2" PAINTED WOOD TRIM, BY F.C. PT-01B TR-01
1/4" 2"
DOOR
3 5/8" METAL FRAMING
5/8"
PAINTED WOOD DOOR FRAME, BY F.C. PT-01B
1/2"
1/4"
G.C. TO SHIM AS REQ'D
6" METAL TRACKS
3' - 0 1/2"
TM
BOH (PUSH)
OSBORN
WD-01
NEW DUMMY LEVERS BOTH SIDES OF DOOR
NEW KICK PLATE AT PUSH SIDE ONLY
NEW KICK PLATE AT PUSH SIDE ONLY
SALES (PULL)
SALES (PUSH)
NEW PRIVACY LEVERSET, PUSH BUTTON AT RESTROOM SIDE
DOOR TYPE "D"
DOOR TYPE "C" SECTION DETAIL
1/2" 1"
5/8" TYPE 'X' GYP. BOARD
VERIFY WITH F.C. SHOP DWGS. 1/2"
1/2"
1/2" 1"
WALL BASE AS SCHEDULED BELOW, BY G.C.
DOUBLE 20 GA. METAL STUDS @ JAMB
PT-01B
EXISTING LOCKSET LEVER HANDLE
3" WHITE VINYL RETAIL TENANT LOGO; SIGNAGE FILED UNDER SEPARATE PERMIT
3' - 0"
ALIGN
7/8"
WALL BASE AS SCHEDULED BELOW B-01 PT-01B
7/8" x 2" PAINTED WOOD TRIM BY F.C. PT-01B TR-01
EQ
EQ 4 1/2"
NEW DUMMY LEVER, BY F.C.; SEE DOOR HARDWARE SCHEDULE
2" 1/4"
1/16" MAX
1/16" MAX
SPRING HINGE, BY F.C.; REF. DOOR HARDWARE SCHEDULE
4 1/2"
3' - 0" DOOR 1/4"
SALES (PULL)
2" 1/4"
9"
5/8" TYPE 'X' GYP. BOARD
FUTURE SIGN
EXISTING EXIT DEVICE
V.I.F.
7 1/4" 1 1/4"
1 7/8"
BLOCKING AS REQ'D, BY G.C.
EXISTING STOREFRONT DOORS AND HARDWARE TO REMAIN U.N.O.
EXISTING DOOR AND HARDWARE TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION AND CONSTRUCTION, CLEAN AND PAINT; FINISH TO MATCH PT-01B
4 1/8"
PAINTED WOOD DOOR FRAME, BY F.C. PT-01B
V.I.F.
1/2" x 1 1/4" PAINTED WOOD DOOR STOP, BY F.C. PT-01B
V.I.F.
EXISTING HOLLOW METAL DOOR FRAME PT-01B
5' - 0"
7/8" x 2" PAINTED WOOD TRIM, BY F.C. PT-01B TR-01
3' - 0" DOOR
EXIT CORRIDOR (PULL)
MIRROR AT DOOR, BY G.C. GL-02
1/4"
2120 SOUTH BLVD, SUITE #2 CHARLOTTE, NC 28203
3'-3" ROUGH OPENING
6' - 0"
EXISTING CLOSER
VENEER WOOD W/ MDF CORE DOOR BY F.C., REF. DOOR SCHEDULE WD-01
B.O.H. (PUSH)
RETAIL TENANT
SCALE: 3" = 1'-0"
V.I.F.
4
SCALE: 3" = 1'-0"
RESTROOM (PULL)
DOOR TYPE "C"
8' - 0"
DOOR TYPE " D" SECTION DETAIL
7' - 0" DOOR
5
ENGINEERING
990 West Third Avenue - Suite 200 | Columbus, OH 43212 1100 Superior Avenue - Suite 300 | Cleveland, OH 44114 (614) 556-4272 www.osborn-eng.com
NEW 7-PIN SMALL FORMAT INTERCHANGEABLE CORE 'BEST' LOCKS
BOH (PUSH) DOOR TYPE "B"
DOOR TYPE "A"
STAMP
3
DOOR TYPE " D" PLAN DETAIL - MIRROR DOOR
1
SCALE: 3" = 1'-0"
DOOR TYPES SCALE: 1/2" = 1'-0"
DOOR SCHEDULE
DOOR
TENANT'S G.C. TO CHAMFER CORNER @ 45 ANGLE AT BOTH SIDES OF DOOR AND PAINT ALL VISIBLE SURFACES PT-01B WALL BASE AS SCHEDULED BELOW BY TENANT'S G.C. B-01 PT-01B
VESTIBULE (PUSH)
45°
2"
5/8"
5/8"
2"
45°
5/8" TYPE 'X' GYP. BOARD
4 7/8"
BLOCKING AS REQ'D DOUBLE 20 GA. METAL STUDS @ JAMB
WALL BASE AS SCHEDULED BELOW BY LANDLORD'S G.C. B-01 PT-01E
5/8" TYPE 'X' GYP. BOARD. (TO BE WATER-RESISTANT AT WET WALLS)
TENANT'S G.C. TO CHAMFER CORNER @ 45 ANGLE AT BOTH SIDES OF DOOR AND PAINT ALL VISIBLE SURFACES PT-01E
HINGE; REF. DOOR HARDWARE SCHEDULE
2
2"
3'-0" DOOR 1/8"
DOOR TYPE C" PLAN DETAIL SCALE: 3" = 1'-0"
ADA RESTROOM (PULL)
2" 1/8"
HOLLOW METAL DOOR; REF. DOOR SCHEDULE
FRAME
DOOR TYPE
DOOR NO.
DESCRIPTION
MATERIAL
FINISH
HARDWARE SET
WIDTH
SIZE HEIGHT
THK
A
EX-01 EX-01
STOREFRONT ENTRY DOOR
METAL / GLASS
EXG
1
2' - 11 3/4"
9' - 0"
1 3/4"
B
EX-02 EX-02
BOH EXIT DOOR
EX'G
PT-01B TENANT SIDE
2
3' - 0"
7' - 0"
1 3/4"
C
EX-03 EX-03
DOOR TO RESTROOM
HOLLOW METAL
PT-01E
3
3' - 0"
7' - 0"
1 3/4"
4 7/8"
2 / A-601
D
04 04
DOOR TO BOH
WOOD / MIRROR
WD-01/GL-02
4
3' - 0"
7' - 7 1/8"
1 3/4"
7 1/4"
3/A-601
HOLLOW METAL DOOR FRAME
LEVERSET, REF. DOOR HARDWARE SCHEDULE
*SEE DOOR SWING DIRECTION ON CONSTRUCTION PLAN, TYP.
THROAT DIM.
JAMB DETAIL
HEAD DETAIL
THRESHO MATERIAL LD DETAIL
VIF
-
-
3/A-600
EX'G
EX'G
10 3/4"
-
-
--
EX'G
PT-01B TENANT SIDE
4 / A-601
--
HOLLOW METAL
PT-01E
--
5/A-601
--
WOOD
PT-01B
--
FINISH
F.R.
SIGNAGE
NOTES (*F/I = FURNISH & INSTALL)
G.C. TO PROVIDE WHITE 1"H VINYL LETTERS STATING EXISTING STOREFRONT ENTRY DOOR AND HARDWARE TO REMAIN; G.C. TO 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS PROVIDE NEW 7-PIN SFIC 'BEST' LOCK AND 6 SETS OF KEYS HOURS' AT THE EGRESS SIDE DOOR HEADER EXISTING BOH EXIT DOOR AND HARDWARE TO REMAIN; G.C. TO PROVIDE NEW 7-PIN SFIC 'BEST' LOCK AND 6 SETS OF KEYS 45 MINS VIF ---
LL'S G.C. TO PROVIDE BLACK RESTROOM SIGNAGE WITH WHITE LETTERS AS PER LOCAL CODE REQUIREMENTS
F/I BY LL'S G.C.; TENANT G.C. TO REPLACE HINGES AND LEVERSET WITH BLACK HARDWARE. REF. HARDWARE SCHEDULE DOOR, FRAME, AND HARDWARE FURNISHED BY F.C. U.N.O. AND INSTALLED BY G.C. SILENCERS AND MIRROR BY G.C. REF. HARDWARE SCHEDULE
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218259 DATE: 02/27/2019
DOOR HARDWARE SCHEDULE
DRAWN BY: Author
SET #1 - STOREFRONT ENTRY DOORS - EXISTING
SET #2 - BOH EXIT - EXISTING TO REMAIN
SET #3 - DOOR TO RESTROOM
SET #4 - MIRROR DOOR
NOTE: EXISTING HARDWARE TO REMAIN; G.C. TO CONFIRM EXISTING LOCK IS SFIC AND PROVIDE NEW 'BEST' LOCK CORE OR APPROVED EQUAL 7-PIN SMALL FORMAT INTERCHANGEABLE CORE AND 6 SETS OF KEYS; IF EXISTING LOCK IS NOT SFIC; G.C. TO REPLACE LOCK AND CORE PER ABOVE FINISH: COLOR TO MATCH ADJ
NOTE: EXISTING HARDWARE TO REMAIN; G.C. TO CONFIRM EXISTING LOCK IS SFIC AND PROVIDE NEW 'BEST' LOCK CORE OR APPROVED EQUAL 7-PIN SMALL FORMAT INTERCHANGEABLE CORE AND 6 SETS OF KEYS; IF EXISTING LOCK IS NOT SFIC; G.C. TO REPLACE LOCK AND CORE PER ABOVE FINISH: COLOR TO MATCH ADJ
EXISTING HARDWARE TO BE REPLACED, SEE BELOW.
LEVERS (BY F.C.): (2) SCHLAGE F170 LAT 622, LATITUDE DUMMY LEVER; FINISH: 622 MATTE BLACK
LEVERSET: (1 SET) SCHLAGE F40 LAT 622, LATITUDE (PRIVACY) LEVERSET; FINISH: 622 MATTE BLACK
DEADLOCK (BY F.C.): (1 SET) SCHLAGE B560B, DEADLOCK LESS SFIC WITH ADA COMPLIANT THUMBTURN; FINISH: 622 CUSTOM MATTE BLACK
DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: BLACK 693
CYLINDER - MORTISE FOR DEADLOCK (BY G.C.): (1) 'BEST' LOCK 1E-74-C181-RP2, G.C. TO PROVIDE 7-PIN SMALL FORMAT INTERCHANGEABLE CORE MORTISE CYLINDER IF USING APPROVED EQUAL; G.C. TO PROVIDE 6 SETS OF KEYS;FINISH: POWDER COATED TO MATCH MT-02
HINGES: (3 PAIR) EMTEK 92015 4 1/2"x4 1/2"; FINISH: BLACK US19
HINGES (BY F.C.) : (3 PAIR) EMTEK 4" x 4" BUTT SPRING HINGE; 95014; FINISH: MATTE BLACK; US19
KICK PLATE: (1) IVES 8400 - 10"X34"; NMH-A; FINISH: BLACK PLASTIC
KICK PLATE (BY F.C.): (1) IVES 8400 - 10"X34"; NMH-A; FINISH: BLACK PLASTIC
WALL STOP: (1) IDH 'CUP' STOP 13018; FINISH: 019 MATTE BLACK
WALL STOP (BY F.C): (1) IVES WS65; FINISH: ALUMINUM: US27
SILENCERS (BY G.C.): (3) IVES SR66; FINISH WHITE
SILENCERS (BY G.C.): (3) IVES SR66; FINISH WHITE
NOTE: KICK PLATE TO BE INSTALLED ON PUSH SIDE ONLY; INSTALL WALL STOP ON RESTROOM SIDE.
NOTE: KICK PLATE TO BE INSTALLED ON BOH SIDE ONLY; INSTALL WALL STOP ON BOH SIDE. G.C. TO PROVIDE SILENCERS AND G.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO DOOR
CHECKED BY: Checker AREA: 1,400 SF
#
ISSUE ISSUE FOR LL APPROVAL / BID ISSUE FOR CONSTRUCTION
DATE 02/27/2019 03/04/2019
DOOR & HARDWARE SCHEDULE & DETAILS
A-601
TENANT
ARCHITECT OF RECORD:
DRAWING LIST
ABBREVIATIONS
ISSUE
LANDLORD'S REPRESENTATIVE
CONTACTS: JACKIE RENTON ATLAS CAPTIAL GROUP,LLC 450 PARK AVENUE, 4TH FLOOR NEW YORK, NY 10022 EMAIL: JRENTON@ATLAS-CAP.COM M: 212-554-2227
ARCHITECT OF RECORD
O'NEIL LANGAN ARCHITECTS 15 W 37TH ST, 15TH FL NEW YORK, NY 10018
CONTACT: STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 F: 212-279-2671 JENNIFER PALMA JENNIFER@OLARCH.COM
MEP ENGINEER
FISKAA FISKAA ENGINERRING 589 EIGHTH AVENUE NEW YORK NEW YORK 10018
CONTACT: MICHAEL SZABO EMAIL: MSZABO@FISKAA.COM P: 646-940-8717 X 8717
STRUCTURAL ENGINEER
N/A
OWNER'S REPRESENTATIVE
O'NEIL LANGAN 15 WEST 37TH STREET 15TH FLOOR NEW YORK, NY 10018
CONTACT: STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 x 231
42 CROSBY STREET SUITE 1B NEW YORK, NY 10012 AREA OF WORK TENANT SPACE SUIT 1B (1807 SQFT)
42 CROSBY STREET, SUITE 116, NEW YORK, NT 10012
TOM ENNIS ASSOCIATES 33 BOND STREET-LOWER LEVEL NEW YORK, NY 10012
CONTACT: TOM ENNIS EMAIL: ENNIS.TOM@GMAIL.COM M: 917-921 6112
NORTH
2
AREA PLAN
1
SCALE: N.T.S.
--
SITE PLAN SCALE: 1" = 100'-0"
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
SHEET TITLE ARCHITECTURAL COVER SHEET ACCESSIBILITY COMPLANCE RESPONSIBILITY SCHEDULE EGRESS AND ACCESSIBILITY PLAN DEMOLITION PLAN DEMOLITION REFLECTED CEILING PLAN DEMOLITION POWER AND SIGNAL PLAN CONSTRUCTION PLAN FIXTURE PLAN REFLECTED CEILING PLAN POWER AND SIGNAL PLAN FLOOR AND WALL FINISH PLAN SLAB LEVEL PLAN BUILDING SECTIONS BUILDING SECTIONS INTERIOR ELEVATIONS - SALES SHOP INTERIOR ELEVATIONS - LOUNGE SHOP INTERIOR ELEVATIONS - FR AND FR LOUNGE
A-305.00
INTERIOR ELEVATIONS - VESTIBULE, STORAGE ROOM AND ADA FR
A-306.00 A-307.00
INTERIOR ELEVATIONS - BOH ENLARGED ADA RESTROOM PLAN AND ELEVATIONS
A-500.00 A-501.00 A-502.00 A-600.00 A-601.00 A-602.00 EN-100.00
CEILING CONSTRUCTION DETAILS CONSTRUCTION AND CEILING DETAILS CONSTRUCTION AND CEILING DETAILS PARTITION, TRIM, AND THRESHOLD DETAILS DOOR AND HARDWARE SCHEDULE DOOR AND THRESHOLD DETAILS ENERGY CODE ENERGY CODE COMPLIANCE FORMS
M-100.00 M-101.00 M-102.00 M-300.00 M-700.00 M-701.00
MECHANICAL H.V.A.C. TITLE SHEET H.V.A.C. SPECIFICATIONS SHEET 1 OF 2 H.V.A.C. SPECIFICATIONS SHEET 2 OF 2 H.V.A.C. PLANS AND SCHEDULES H.V.A.C. DETAILS SHEET 1 OF 2 H.V.A.C. DETAILS SHEET 2 OF 2
BUILDING CODE ANALYSIS & CODE NOTES 1. SCOPE OF WORK: THIS IS A PERMIT APPLICATION FOR INTERIOR IMPROVEMENTS FOR A NEW RETAIL STORE. THE PROJECT INCLUDES WORK ON THE GROUND FLOOR OF AN EXISTING BUILDING. WORK INCLUDES ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, SPRINKLER, AND FIRE ALARM WORK. NO CHANGE TO EXISTING USE, EGRESS, OR OCCUPANCY. 2. GOVERNING CODES: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO THE REQUIREMENTS OF THE FOLLOWING (INCLUDING AMENDMENTS), AND ANY OTHER FEDERAL, STATE AND LOCAL CODES, LAWS AND ORDINANCES THAT APPLY: - 2014 NEW YORK CITY BUILDING CODE - 2014 NEW YORK CITY ENERGY CONSERVATION CODE - 2014 NEW YORK CITY MECHANICAL CODE - 2014 NEW YORK CITY PLUMBING CODE - 2014 NYBC CHAPTER 11 AND INTERNATIONAL CODE COUNCIL- ACCESSIBLE AND USABLE BUILDING AND FACILITIES (A117.1) - NYC BUREAU OF ELECTRICAL CONTROL (BEC) 3. CONSTRUCTION SERVICE CENTER NEW YORK CITY DEPARTMENT OF BUILDINGS 280 BROADWAY, NEW YORK, NY 10007 4. CONSTRUCTION TYPE: TYPE : 1B FULLY SPRINKLERED NUMBER OF STORIES: 7
A. EXISTING DEMISING PARTITIONS: 1-HR FIRE RATED PARTITION TO CONFORM TO USG TEST NO. 1174-OSU WITH 5/8" TYPE "X" FIRECODE CORE BOTH SIDES OF 3 5/8" 20 GAUGE METAL STUDS. FRAMING AND GYP. BD TO EXTEND TO BOTTOM OF METAL DECK ABOVE. FIRE-RATED ACOUSTICAL CAULKING TO SEAL ALL GAPS AT TOP AND BOTTOM OF PARTITION. G.C. TO PATCH AND RE-SEAL AS REQUIRED TO RESTORE THE DEMISING PARTITIONS TO THEIR ORIGINAL FIRE PROTECTION RATING. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. B. ALL PENETRATIONS (INCLUDING FOR PIPES AND CONDUITS) THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH UL LISTED THROUGH PENETRATION FIRESTOP SYSTEMS AND FIRE-RATED SEALANT WITH RATINGS EQUAL TO THAT OF THE RATED ASSEMBLIES THROUGH WHICH THEY PASS. C. COLUMNS, GIRDERS, BEAMS, JOISTS, DECKS AND SLABS ALL ARE PART OF LANDLORD ASSEMBLY AND HAVE EXISTING FIRE PROTECTION WHICH SHOULD REMAIN. WHERE SUCH FIRE PROTECTION IS DAMAGED, IT SHALL BE RESTORED TO ITS ORIGINAL CONDITIONS AND FIRE PROTECTION RATING. TENANT CEILING (NON-COMBUSTIBLE) DOES NOT FORM A PART OF THE LANDLORD RATED ROOF ASSEMBLY. D. ALL CEILING AND WALL MATERIALS MUST BE CLASS 'A'; INTERIOR FINISHES TO BE CLASS C OR GREATER. DOES NOT APPLY TO TRIM DEFINED AS BASEBOARDS AND MOLDINGS, OR TO MATERIALS LESS THAN 1/28 INCH IN THICKNESS APPLIED DIRECTLY TO SURFACE OF WALLS OR CEILINGS.
BASED ON FIRE SEPARATION DISTANCE (PER 2014 NYCBC, TABLE 602) EXTERIOR WALLS:
5. OCCUPANT GROUP: GROUP "M" (MERCANTILE)
7. OCCUPANT LOAD: (PER 2014 NYCBC: CHAPTER 10, TABLE 1015.1) FLOOR AREA: SALES: 1354 SQ FT / 60 = STOCK: 396 SQ FT / 300 = RESTROOM: 57 SQ FT/ 300= NUMBER OF OCCUPANTS: TOTAL:
11. FIRE RATED ASSEMBLIES:
12. FIRE RESISTANCE RATING REQUIREMENT (PER 2014 NYCBC, TABLE 601) BUILDING ELEMENTS: STRUCTURAL FRAME (COLUMNS, ETC): BEARING WALLS (EXTERIOR): NON BEARING WALLS (EXTERIOR): NON BEARING (INTERIOR): FLOOR CONSTRUCTION ( INCL. SUPPORTS):
23 OCCUPANTS 2 OCCUPANTS 1 OCCUPANT 26 PERSONS
8. EXITS REQUIRED: OCCUPANT LOAD < 50 REQUIRES MINIMUM OF 1 EXIT (PER 2014 NYCBC: SECTION 1006.2) NUMBER OF EXITS REQUIRED BY OCCUPANT LOAD: 1 NUMBER OF EXITS PROVIDED: 1 MAXIMUM TRAVEL DISTANCE TO EXIT: 75 FT (PER 2014 NYCBC: SECTION 1021.2) ACTUAL TRAVEL DISTANCES (REF. G-003 EGRESS PLAN): ROUTE 1: 38'-0" ROUTE 2: 51'-9" ROUTE 3: 67'-8" EGRESS WIDTH PER OCCUPANT SERVED: (0.2) x 28 PERSONS = 5.6 IN 9. EXITS PROVIDED AND DATA: ONE (1) EXIT AT STOREFRONT @ 6'-0" (2 LEAVES X 3'-0") CLEAR WIDTH
--
T-000.00 G-001.00 G-002.00 G-003.00 D-100.00 D-101.00 D-102.00 A-100.00 A-101.00 A-102.00 A-103.00 A-104.00 A-105.00 A-300.00 A-301.00 A-302.00 A-303.00 A-304.00
6. TENANT LEASE AREA: 1807 SQ.FT.
EXPEDITOR
SHEET
MEP ENGINEER:
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
DAN KLACIK EMAIL: DKLACIK@BONOBOS.COM M: 908-801-0655
ISSUE FOR PERMIT
CONTACTS: ELIZABETH COOKSEY EMAIL: E.COOKSEY@MODCLOTH.COM M: 214-207-0672
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
09/07/2018
MODCLOTH 45 W 25TH STREET FLOOR 2 NEW YORK, NY 10010
ADJ. ADJACENT A.F.F ABOVE FINISHED FLOOR A.C.T. ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES BLK. BLOCKING CL CENTERLINE CLR. CLEAR CLG. CEILING CNTR. COUNTER CNT. CENTER CONC. CONCRETE COL COLUMN C.O.W CENTER OF WALL CPT. CARPET CONT. CONTINUOUS CONSTR. CONSTRUCTION C.G. CORNER GUARD CMU CONCRETE MASONRY UNIT DEMO DEMOLITION DWG. DRAWING DIA. DIAMETER DN. DOWN DR. DOOR ELEC. ELECTRICAL E.P. ELECTRICAL PANEL EMER. EMERGENCY EQ. EQUAL (E) EXISTING EA. EACH EXT. EXTERIOR FBO. FURNISHED BY OWNER F.C. FIXTURE CONTRACTOR F.F. FINISH FLOOR F.D. FLOOR DRAIN FR FRAME F.R.T FIRE RETARDANT TREATED F.S. FIRE EXTINGUISHER FURN. FURNISH F.O.W. FACE OF WALL GA. GAUGE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GWB. GYPSUM WALL BOARD HC HOLLOW CORE H.M. HOLLOW METAL HGT. HEIGHT HORIZ. HORIZONTAL IN INCH INST. INSTALL INSUL INSULATION KE KITCHEN EQUIPMENT L.O.D. LEASE OUTLINE DRAWING L.N. LANDLORD MAX MAXIMUM MAT'L. MATERIAL M.D.F. MAIN DISTRIBUTION FACILITY MECH. MECHANICAL MFR. MANUFACTURER MIR. MIRROR MIN. MINIMUM M.R. MOISTURE RESISTANT M.O. MASONRY OPENING N/A NOT APPLICABLE (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPG. OPENING OPP. OPPOSITE PT. PAINT PLWD. PLYWOOD P-LAM. PLASTIC LAMINATE PNL. PANEL QTY. QUANTITY RCP REFLECTED CEILING PLAN RB. RUBBER BASE REINF. REINFORCING REQ'D. REQUIRED REV. REVISED/REVISION R.R. RESTROOM SC SOLID CORE SCHED. SCHEDULE SF. SQUARE FOOT SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE SUSP. SUSPENDED TEMP. TEMPERED TBD TO BE DETERMINED TBV TO BE VERIFIED TYP. TYPICAL UON UNLESS OTHERWISE NOTED V.C.T. VINYL COMPOSITE TILE V.I.F VERIFIED IN FIELD VERT. VERTICAL WD WOOD
A. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. B. A CLEAR AISLE BETWEEN EXITS OF 36" SHALL BE MAINTAINED FREE OF FIXTURES, MERCHANDISE AND OTHER OBSTRUCTIONS. C. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED AND SHALL CONFORM TO 2014 NYCBC.
2 HR 2 HR 1HR 0 HR 2 HR
10â&#x2030;¤X< 30 : 1 HR
13. LIFE SAFETY SYSTEMS: A. FIRE SPRINKLER SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. SPRINKLER CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ON-SITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. B. FIRE ALARM SYSTEM - LANDLORD SYSTEM WITH MODIFICATIONS TO SUIT NEW TENANT WORK. FIRE ALARM CONTRACTOR TO SUBMIT ENGINEERED PLANS FOR FINAL APPROVAL PRIOR TO ON-SITE WORK. CONTRACTOR TO PERFORM SITE VISIT TO VERIFY EXISTING CONDITIONS. C. EMERGENCY LIGHTING - NEW, PROVIDED BY TENANT
HANDICAP ACCESSIBILITY: 11. A. AN ACCESSIBLE ROUTE IS EXISTING FROM THE EXTERIOR TO THIS TENANTS SPACE. SEE ORIGINAL LANDLORD SITE AND BUILDING PLANS ON FILE. B. THIS TENANT SPACE IS FULLY ACCESSIBLE TO ALL AREAS OCCUPIED BY THE PUBLIC, ACCESSIBLE EMPLOYEE WORK AREAS HAVE BEEN PROVIDED. C. WHERE INDICATED PROVIDE INDUSTRY STANDARD ADA APPROVED SIGNAGE, PROPOERLY ADDRESSING RAISED AND BRAILLE CHARACTERS, PICTOGRAMS, FINISH AND CONTRAST, CHARACTER PROPORTION AND HEIGHT, AND MOUNTING HEIGHT. 12. SANITARY FACILITIES: (PER 2014 NYCBC TABLE 2909.1) (1) UNISEX RESTROOM, FULLY ACCESSIBLE TO CUSTOMERS AND EMPLOYEES TO BE PROVIDED. 13. DRINKING FOUNTAIN: (PER 2015 IPC TABLE 2909.1) (1) DRINKING FOUNTAIN THAT COMPLIES WITH THE REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR & (1) DRINKING FOUNTAIN THAT COMPLIES WITH THE REQUIREMENTS FOR STANDING PERSONS TO BE PROVIDED. OR (1) WATER DISPENSING STATION THAT COMPLIES WITH THE REQUIREPMENTS FOR PEOPLE WHO USE A WHEELCHAIR AND STANDING PERSON TO BE PROVIDED IN LIEU OF A DRINKING FOUNTAIN. 14. SERVICE SINK: (PER 2015 IPC TABLE 2909.1) (1) SERVICE SINK TO BE PROVIDED.
E-100.00 E-101.00 E-102.00 E-300.00 E-400.00 E-500.00
ELECTRICAL ELECTRICAL TITLE SHEET ELECTRICAL SPECIFICATIONS (1 OF 2) ELECTRICAL SPECIFICATIONS (2 OF 2) ELECTRICAL POWER PLAN ELECTRICAL LIGHTING PLAN ELECTRICAL, POWER RISER DIAGRAM PANEL SCHEDULE AND DETAIL
FA-100.00 FA-300.00
FIRE PROTECTION FIRE ALARM TITLE SHEET FIRE ALARM FLOOR PLAN
P-100.00 P-101.00 P-300.00 P-700.00
PLUMBING PLUMBING NOTES, LISTS AND SCHEDULES PLUMBING SPECIFICATIONS PLUMBING PLAN AND RISER DIAGRAMS PLUMBING DETAILS
SP-100.00 SP-101.00 SP-102.00 SP-300.00 SP-500.00 SP-700.00
SPRINKLER DRAWINGS SPRINKLER NOTES, LISTS AND SCHEDULE SPRINKLER SPECIFICATIONS SHEET 1 OF 2 SPRINKLER SPECIFICATIONS SHEET 2 OF 2 SPRINKLER PLAN SPRINKLER RISER DIAGRAM SPRINKLER DETAILS
REQUIRED SPECIAL INSPECTIONS:
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231
SPECIAL INSPECTIONS :
14. FLAME SPREAD RATINGS FOR INTERIOR FINISHES: FLAME SPREAD RATINGS FOR INTERIOR FINISHES SHALL COMPLY WITH 2014 NYCBC, TABLE 803.3 BUT IN NO CASE SHALL EXCEED CLASS C, MAX FLAME SPREAD INDEX OF 225; MAX SMOKE-DEVELOPED INDEX OF 450
-MECHANICAL SYSTEM -SPRINKLER SYSTEM -FIRE-RESISTANT PENETRATIONS AND JOINTS
15. FIRE EXTINGUISHERS: (PER 2014 IFC, TABLE 906.1, TABLE 906.3(1)) A. ONE FIRE EXTINGUISHER SHALL BE PROVIDED AT ONE PER 3,000 SF; COVERAGE NOT TO EXCEED 75 FEET IN ANY DIRECTION. TENANT SHALL HAVE AT LEAST ONE IN THE STOCK ROOM AREA. B. PROVISIONS AND INSTALLATION IN THE QUANTITY, TYPE AND LOCATIONS REQUIRED BY THE FIRE MARSHALL SHALL PREVAIL.
ENERGY CODE PROGRESS INSPECTION: -HVAC AND SERVICE WATER HEATING EQUIPMENT -HAVC AN SERVICE WATER HEATING SYSTEM CONTROLS -HVAC INSULATION AND SEALING -MAINTENANCE INFORMATION -LIGHTNING CONTROL
16. HAZARDOUS MATERIALS: TESTING, REMOVAL, AND/OR ENCAPSULATION ARE NOT PART OF THIS CONTRACT. IT IS NOT SUSPECTED ANY HAZARDOUS MATERIALS WILL BE FOUND. IF THE PRESENCE OF HAZARDOUS MATERIAL IS SUSPECTED OR DISCOVERED, NOTIFY THE BUILDING OWNER AND MODCLOTH IMMEDIATELY.
STAMP HERE:
BC 1704.16 BC 1704.23 BC 1704.27
DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
FINAL INSPECTION:
COVER SHEET
T-000.00 SHEET 1 OF 27
RESPONSIBILITY SCHEDULE DESCRIPTION
SIGNAGE
SECURITY
TBD
ADT BUSINESS ED KEISER 111 WINDSOR DR. OAK BROOK,IL 60523 PH: 630-788-7858 EKEISER@ADT.COM
LIGHTING
CAPITAL LIGHT ANGELA McCOY 270 LOCUST STREET HARTFORD, CT 06141 PH: 860-520-2387 C: 860-729-2717 ANGELA.MCCOY@CAPITALLIGHT.COM FIXTURE CONTRACTOR
ICON DESIGN KEN BERGMANN 230 SOUTH BEMISTON ST LOUIS, MO 63105 P: 314-725-5721 x109 C: 314 295-9663 KENB@ICONFIXTURES.COM DRAPERY FABRIC
BRAD JOBE BESPOKE FURNITURE BRAD JOBE 231 W 29TH ST SUITE 300 NEW YORK, NY 10001 PH: 212-216-9259 BRAD@BRADJOBE.COM FLOORING
UNCONVENTIONAL FLOORING JASON VALENTA PH: 317-281-8223 VALENTAJASON@HOTMAIL.COM
01.
AUDIO SYSTEM
PLAY NETWORK AUDIO JEFF ROMAN C: 425-629-2760 JROMAN@PLAYNETWORK.COM
SHOPPER TRAK
RETAIL NEXT EDWARD SCHLODDER OFFICE ON THE BEACH 3 LAGOON BEACH DRIVE MILNERTON, SOUTH AFRICA 7441 P: (408) 740-5340 Ext 1035 EDWARD.SCHLODDER@RETAILNEXT.NET
02.
N/A
EXISTING
1. PERMITS AND FEES
G.C.
G.C.
2. INSPECTION / COORDINATION
G.C.
G.C.
3. SPECIAL INSPECTIONS
OWN
OWN
4. TEMPORARY HEAT
G.C.
G.C.
G.C.
AS PER LOCAL CODE AND FIRE DEPARTMENT
G.C.
5. BOH REFRIGERATOR (REF-2)
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL; COORD. W/ MEP'S; COORD. INSTALL WITH BUILT IN CABINETRY
5. TEMPORARY ELECTRICAL
G.C.
G.C.
6. ADA SIGNAGE
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL PER LOCAL CODE
6. TEMPORARY ENCLOSURE
G.C.
G.C.
7. CLEAN UP
G.C.
G.C.
1. MILLWORK/FIXTURES & FURNITURE
F.C.
F.C.
G.C.
FLOOR, WALL, & FITTING ROOM FIXTURES FURNISHED BY F.C. / INSTALLED BY G.C.
8. INSURANCE
G.C.
G.C.
2. BEST LOCKS
G.C.
G.C.
G.C.
G.C. TO ORDER & PREPAY / G.C. TO INSTALL LOCKS AND PROVIDE 6 SETS OF KEYS
3. DEADLOCK AT BOH DOOR
OWN
G.C.
OWNER TO PROVIDE DEADLOCK AND 6 SETS OF KEYS / F.C. TO STORE AND DELIVER WITH FIXTURE PACKAGE / G.C. TO INSTALL LOCK AT BACK OF HOUSE DOOR
3. SHELVING @ BACK OF HOUSE
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL FROM PIPP; G.C. TO PROVIDE LAYOUT FROM PIPP HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE.
6. MANAGER'S DESK & SHELVES ABOVE
G.C.
G.C.
G.C.
G.C. TO FURNISH AND INSTALL FROM THE CONTAINER STORE; G.C. TO PROVIDE LAYOUT FROM CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE.
OWN
OWN
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
B. DUCTWORK / DIFFUSERS
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
2. TEMPERATURE CONTROLS
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
3. EXHAUST FANS
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
A. WATER
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
B. WASTE
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
C. VENT
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
9. JOB PHONE
G.C.
G.C.
10. FINAL CLEANING
G.C.
G.C.
OLA / MEP ENG
3. MECHANICAL SHOP DRAWINGS AND EQUIPMENT
OLA / MEP ENG
4. ELECTRICAL EQUIPMENT AND DEVICES
OLA / MEP ENG
5. PLUMBING FIXTURES
OLA / MEP ENG
6. STRUCTURAL SHOP DRAWINGS
X
OLA / ENG.
7. STOREFRONT SHOP DRAWINGS AND SAMPLES
X
OLA
06.
2.
3. 4.
5. 6.
7.
8.
9.
12.
SITE WORK X OWN
OWN
OWN'S VEN
5. MANAGER'S CHAIR
3. DEMOLITION
G.C.
G.C.
G.C.
4. LOCKERS
4. SAW CUT/ DRILL SLAB
G.C.
G.C.
G.C.
AS REQUIRED FOR ELECTRICAL, PLUMBING, & FLOORING
G.C.
G.C.
G.C.
1. LEVELING OF CONCRETE FLOOR
G.C.
G.C.
G.C.
2. VAPOR BARRIER
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
X
G.C. TO CONFIRM SLAB CONDITIONS
G.C. PATCH AND REPAIR FLOOR AS REQUIRED, AND PREPARE FOR NEW FLOOR FINISH
2. CONCRETE BLOCK
X
6. PLUMBING FIXTURES
G.C.
G.C.
G.C.
COORD. W/ MECH. DWGS. & PLUMBING SCHEDULE
3. LIME STONE
X
7. WATER HEATER
G.C.
G.C.
G.C.
SEE MECHANICAL DWGS.
8. SPRINKLER SYSTEM
G.C.
G.C.
G.C.
COORD. W/ SPRINKLER DWGS; COORD. W/ EXISTING CONDITIONS
G.C.
G.C.
G.C.
EXISTING TO REMAIN
LL
LL.
LL
WATER COOLER PROVIDED
11. FIRE/SMOKE DAMPER
G.C.
G.C.
G.C.
COORD. W/ MECH. DWGS. & LOCAL CODE REQUIREMENTS
12. FIRE STOP / SMOKE BARRIER
G.C.
G.C.
G.C.
COORD. W/ MECH. DWGS. & LOCAL CODE REQUIREMENTS
G.C.
G.C.
G.C.
SEE ELECTRICAL DWGS.
G.C.
G.C.
G.C.
RELOCATED; COORD. W/ ELECTRICAL DWGS.
G.C.
G.C.
G.C.
SEE ELECTRICAL DWGS.
4. LIGHT SWITCHES
OWN
OWN/VEN
G.C.
SWITCHES PROVIDED BY OWNERS VENDOR; G.C. TO PROVIDE MASTER OVERRIDE SWITCH
5. LIGHT FIXTURES IN CEILING
OWN
OWN/VEN
G.C.
G.C. TO COORD. & INSTALL; G.C. TO PROVIDE LAMPS FOR SM-1 AND P-1 FIXTURES. REF. A-102A RCP
6. LIGHT FIXTURES IN MILLWORK
OWN
OWN/VEN
G.C.
G.C. TO COMPLETE FINAL ELECTRICAL CONNECTION FOR ILLUMINATED MIRRORS
7. EXIT SIGNAGE
OWN
OWN/VEN
G.C.
SEE ELECTRICAL DWGS
8. EXHAUST FAN
G.C.
G.C.
G.C.
SEE ELECTRICAL DWGS.
9. EMERGENCY LIGHTING
OWN
OWN/VEN
G.C.
G.C. TO COORD. W/ NEW WORK DWGS
10. TELEPHONE CONDUIT
G.C.
G.C.
G.C.
11. TELEPHONE JACKS/SETS/WIRES
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
OWN
OWN
14. TIME CLOCK
G.C.
G.C.
G.C.
MULTI-CHANNEL; COORD. W/ ELECTRICAL DWGS.
15. FLOOR OUTLETS
G.C.
G.C.
G.C.
G.C. TO PROVIDE DEDICATED 4-GANG FLOOR BOX WITH COVER; G.C. IS RESPONSIBLE FOR ANY PATCHING AND REPAIRING OF THE FLOORING REQUIRED FOR INSTALLATION OF THE FLOOR BOX; COORD BEFORE SLAB IS POURED.
16. CONDUIT FOR COMPUTER SYSTEM
G.C.
G.C.
G.C.
COORD. W/ BRAND WAVE
17. LIFE SAFETY (F.A.)
G.C.
G.C.
G.C.
G.C. TO COORD W/ MEP ENGINEER
18. CAMERA SECURITY SYSTEM
OWN
OWN
G.C.
MODCLOTH VENDOR FURNISHES & INSTALLS CAMERA WIRING, CAMERA, & CPU; G.C. TO PROVIDE CONDUIT & PULL, SCHEDULE AND COORD. W/ VENDOR
19. SHOPPER TRACK SYSTEM
OWN
OWN
G.C.
G.C. TO PROVIDE PULL STRING AS REQ'D; COORD. W/ VENDOR
METALS X
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/INSTALLED
B. INTERIOR PARTITIONS
G.C.
G.C.
G.C.
G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS
C. FURRING
G.C.
G.C.
G.C.
G.C. TO COORDINATE IN-WALL BLOCKING WITH REQUIRED MILLWORK ITEMS
3. FRAMING FOR HVAC
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
X
G.C.
4. STOREFRONT SYSTEM
X
G.C.
5. METAL DECKING
X
G.C.
G.C. TO ENSURE FIRE-PROOFING RATING IS MAINTAINED/REPLACED
G.C.
G.C.
G.C.
G.C. TO COORD. W/ FIXTURE CONTRACTOR
2. SHELVES
G.C.
G.C.
G.C.
G.C. RESPONSIBLE FOR BACK OF HOUSE SHELVES ONLY; COORD. W/ MODCLOTH
3. COUNTERS
G.C.
G.C.
G.C.
4. PLYWOOD
G.C.
G.C.
G.C.
FOR TELE/DATA BOARD BY G.C.
G.C.
G.C.
G.C.
G.C. TO COORD. ALL MILLWORK BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR
11. BOH SHELVING LAYOUT
OLA / MODCLOTH
1. CAULKING
G.C.
G.C.
G.C.
12. WOOD JOINERY AND MILLWORK
OLA / MODCLOTH
2. SEALANT
G.C.
G.C.
G.C.
G.C. TO PROVIDE A SUBMITTALS SCHEDULE AT CONSTRUCTION KICK-OFF FOR ARCHITECT'S REVIEW
3. WATERPROOFING
G.C.
G.C.
G.C.
PROVIDE WATER PROOFING AT ALL WET AREAS
GENERAL NOTES
4. INSULATION
G.C.
G.C.
G.C.
G.C. TO PROVIDE INSULATION @ STOREFRONT CURB WALLS
G.C.
G.C.
2. BACK OF HOUSE DOOR
G.C.
G.C.
G.C.
3. RESTROOM DOOR
G.C.
G.C.
G.C.
4. DOOR HARDWARE
G.C.
G.C.
G.C.
G.C.
G.C.
G.C.
10. G.C. SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. G.C. SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. 11. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING - CREATED OR EXPOSED DURING CONSTRUCTION, PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES.
G.C.
G.C.
G.C.
NEW RAISED SLAB AND TOPPING SLAB
KEY
DESCRIPTION
B. WALK OFF MATT- ENTRY
G.C.
G.C.
G.C.
NEW REMOVABLE WALK-OFF MAT
G.C. (OR) GC
GENERAL CONTRACTOR
C. FITTING ROOMS & VESTIBULE
G.C.
G.C.
G.C.
NEW WOOD FLOOR; FLOAT TO ALIGN W/ ADJACENT FLOORS
OWN. (OR) OWN
OWNER/TENANT
D. RESTROOM
G.C.
G.C.
G.C.
NEW RAISED SLAB AND TILE
LL
LANDLORD
E. BACK OF HOUSE & STORAGE CLOSET
G.C.
G.C.
G.C.
NEW RAISED SLAB
F.C. (OR) FC
FIXTURE CONTRACTOR
F. LOUNGE
OWN
OWN
OWN
NEW WOOD FLOOR; FLOAT TO ALIGN W/ ADJACENT FLOORS
AV
AUDIO/VISUAL CONSULTANT
X
N/A OR EXISTING
A. SALES AREA
G.C.
G.C.
G.C.
G.C. TO COORD. IN-WALL BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR
N/A
NOT APPLICABLE-DOES NOT APPLY TO PROJECT
B. LOUNGE, FITTING ROOMS & VESTIBULE
G.C.
G.C.
G.C.
G.C. TO COORD. IN-WALL BLOCKING REQUIREMENTS W/ FIXTURE CONTRACTOR
EXISTING
ALREADY LOCATED ON SITE
C. RESTROOM
G.C.
G.C.
G.C.
ENSURE MOISTURE RESIST. GWB IS INSTALLED IN AND AROUND WET AREAS
PROVIDE
TO FURNISH & INSTALL ( WHEN TENANT RESPONSIBILITY, TENANTS SUPPLIERS TO FURNISH & INSTALL)
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
D. BACK OF HOUSE & STORAGE CLOSET
G.C.
G.C.
G.C.
ENSURE MOISTURE RESIST. GWB IS INSTALLED IN AND AROUND WET AREAS
FURNISH
TO SUPPLY AND DELIVER
PROJECT NO.: 218231
INSTALL
TO INSTALL
DATE: 08/20/2018
A. SALES AREA & LOUNGE
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW PAINTED WOOD BASE
OWN/VEN
OWNER'S VENDOR
DRAWN BY: GR, RE, NK
B. FITTING ROOMS & VESTIBULE
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW PAINTED WOOD BASE
CHECKED BY: JSP
C. RESTROOM
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW TILE BASE
AREA: 1807 SQ.FT
D. BACK OF HOUSE
G.C.
G.C.
G.C.
G.C. TO PROVIDE NEW RUBBER WALL BASE
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
5. CEILING
12. PRIOR TO PROJECT CLOSEOUT, G.C. SHALL COORDINATE WITH THE BUILDING OWNER: ANY TESTS, SUBMITTAL OF AS-BUILT DOCUMENTATION AS REQ'D, AND ALL REQUIREMENTS FOR PROJECT ACCEPTANCE. 13. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.
A. SALES AREA
G.C.
G.C.
G.C.
NEW SUSPENDED GWB CEILING
B. FITTING ROOMS & LOUNGE
G.C.
G.C.
G.C.
NEW SUSPENDED GWB CEILING
C. RESTROOM
G.C.
G.C.
G.C.
NEW SUSPENDED GWB CEILING
G.C.
G.C.
G.C.
EXISTING CEILING; G.C. TO MAINTAIN ACOUSTIC AND FIRE RATED CEILING
G.C.
G.C.
G.C.
OWN
OWN
OWN/VEN
G.C.
G.C.
G.C.
4. POS SYSTEM
OWN
OWN
OWN/VEN
5. STOREFRONT SIGNAGE
OWN
OWN
OWN/VEN
6. DRAPERY
OWN
VEN
G.C.
D. BACK OF HOUSE & STORAGE CLOSET 10.
CONDUIT & PULL STRINGS BY G.C. AS REQ'D; G.C. TO SCHEDULE & COORD. INSTALL W/ VEND
STAMP HERE:
A. SALES AREA
4. BASE
G.C. SHALL COMPLETE ALL WORK WITHOUT DISRUPTION TO ADJACENT BUILDING TENANTS.
G.C./ OWN
RESPONSIBILITY SCHEDULE LEGEND
3. WALLS
G.C. SHALL CONDUCT WORK IN A SAFE AND TIMELY MANNER. PROVIDE AND MAINTAIN ALL NECESSARY GUARDS FOR PREVENTION OF ACCIDENTS. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION, SAFETY ISSUES, CONTROL OR SUPERVISION OF THE WORK, NOR ITEMS RELATED TO STOPPAGE OF WORK. THE AUTHORITY TO STOP WORK REMAINS SOLELY WITH MODCLOTH (OWNER) AND G.C..
X
13. AUDIO SYSTEM
DOOR HARDWARE PROVIDED BY G.C.
2. FINISH FLOORING
G.C. SHALL INSTALL ALL NECESSARY MEANS TO PROTECT THE PUBLIC , THE BUILDING, AND NEW WORK FROM DAMAGE DURING THE DURATION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO FLOOR PROTECTION, TEMPORARY DUST PARTITIONS AND BARRICADES.
X
FINISHES 1. GYPSUM FOR PARTITIONS
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE HIGHEST QUALITY INDUSTRY STANDARDS FOR MATERIAL AND INSTALLATION. ALL WORK WILL BE WARRANTED FOR ONE YEAR MIN. BY THE G.C. UNLESS STATED OTHERWISE. REPAIR OR REPLACEMENT OF WARRANTED WORK AND ANY AREA AFFECTED BY FAILURE OF WARRANTED ITEM SHALL BE THE G.C.'S RESPONSIBILITY.
X
12. BUZZER
DOORS G.C.
ELECTRICAL
3. TRANSFORMER
1. BLOCKING
X
X
2. PANELS
MOISTURE CONTROL
G.C. IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.
14.
CARPENTRY
1. ENTRY DOOR
X
1. DISTRIBUTION
OLA
G.C. SHALL THOROUGHLY REVIEW ALL EXISTING CONDITIONS PRIOR TO BIDDING. ANY DISCREPANCIES BETWEEN THE BID DOCUMENTS AND EXISTING CONDITIONS SHALL BE BROUGHT THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO BIDDING.
9. WATER METER 10. WATER FOUNTAIN
10. PAINT DRAW DOWNS
09.
X
X
5. FURRING
ALL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP.
G.C. TO SCHEDULE AND COORD. DELIVERY
1. BRICK
OLA / MODCLOTH
G.C. SHALL FILE ANY NECESSARY CERTIFICATES OF INSURANCE WITH THE LOCAL DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED.
OWN/ G.C.
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
5. PLUMBING
MASONRY
9. FLOOR FINISH SAMPLES
G.C. SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS, FEES, APPROVALS, AND TEST FOR THE WORK. ALL CONSTRUCTION AND MATERIALS SHOULD COMPLY WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS / LAWS / CODES.
OWN/F.C.
MECHANICAL
A. UNIT
CONCRETE SLAB
X
MEP ENGINEER:
1. HVAC
OLA
07.
13.
FURNISHED AND INSTALLED BY SIGNAGE VENDOR; G.C. TO SUPERVISE AND COORD. INSTALL
FURNISHINGS
2. BARRICADE GRAPHICS
8. DOORS AND HARDWARE
08. 1.
SPECIAL INSPECTOR CONTRACTED BY OWNER(MODCLOTH); G.C. TO COORD. SCHEDULE AND ACCESS TO SITE FOR INSPECTIONS
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
EQUIPMENT
G.C.
A. TENANT DEMISING WALLS
2. FIRE ALARM SHOP DRAWINGS AND DEVICES
COMMENTS
3. FIRE EXTINGUISHER
2. METAL STUDS
OLA / MEP ENG.
INSTALL
OWN/VEN
4. EXPANSION JOINT MATERIAL
1. SPRINKLER SHOP DRAWINGS AND DEVICES
FURNISH
OWN/VEN
3. CONCRETE SLAB
PROVIDE
PROVIDE
OWN/VEN
BANDWAVE SYSTEMS, LLC ADIL ZAIDI 438 HIGH ST BURLINGTON, NJ 08016 P: 888-396-7182 M: 609-699-4265 AZAIDI@BANDWAVESYSTEMS.COM
N/A
EXISTING
2. INTERIOR LED SIGNS
1. STRUCTURAL STEEL
DESCRIPTION
BUILDING PERMIT FEE BY OWNER(MODCLOTH); CONTRACTOR SPECIFIC PERMITS INCLUDING, FIRE ALARMS, SPRINKLER, PLUMBING & ELECTRICAL BY G.C. ( IF APPLICABLE)
N/A
OWN/VEN
X
G.C. REQUIRED SHOP DRAWINGS
DESCRIPTION
OWN/VEN
6. ENTRY VESTIBULE FLOORING
05.
COMMENTS
OWN/VEN
X
FIRECLAY TILE SARAH ROORDA PH: 646-520-9523 SARAH@FIRECLAYTILE.COM
INSTALL
1. STOREFRONT SIGNS
5. SIDE WALK
RESTROOM TILE
FURNISH
11.
DATA
04.
PROVIDE
GENERAL REQUIREMENTS
1. BARRICADE
03.
ARCHITECT OF RECORD:
RESPONSIBILITY SCHEDULE
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
REQUIRED VENDORS CONTACT INFO
X
SPECIALTIES 1. TOILET ROOM ACCESSORIES 2. SPEAKERS- AUDIO SYSTEM 3. STOREFRONT SYSTEM
X
CONDUIT & PULL STRINGS BY G.C. AS REQ'D; G.C. TO SCHEDULE & COORD. INSTALL W/ VENDOR
FURNISHED AND INSTALLED BY SIGNAGE VENDOR; G.C. TO SUPERVISE AND COORD. INSTALL FURNISHED BY OWN. VENDOR; DELIVERED TO G.C. FOR INSTALLATION
RESPONSIBILITY SCHEDULE
G-002.00 SHEET 3 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
POINT B FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
3' - 0"
CLEAR
3' - 0"
CLEAR
0" 3' R EA CL
CLEAR
EXIT 1
3' - 0"
CLEAR
3' - 0"
FE
3' - 0" CLEAR 3' - 0"
FE
POINT C
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
CLEAR
TRAVEL DISTANCE FROM POINT A: 38'-0" TRAVEL DISTANCE FROM POINT B: 51'-9"
POINT A
TRAVEL DISTANCE FROM POINT C: 67'-8"
1
EGRESS PLAN SCALE: 1/4" = 1'-0"
EGRESS PLAN HATCH AND SYMBOL LEGEND SYMBOL
DESCRIPTION EXISTING PARTITION TO REMAIN
FIRE EXTINGUISHER NOTE: ADA COMPLIANT TYPE "ABC" ALL PURPOSE CHEMICAL FIRE EXTINGUISHER & MOUNTING BRACKET TO BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR AT A HEIGHT OF 5'-0" MAX. SPECIFICATIONS:
2" MIN
MOUNTING BRACKET AS REQUIRED
(48" MAX.)
1' - 0"
FIRE EXTINGUISHER
3' - 4"
NEW PARTITION
36" MIN
4"
STAMP HERE:
FIRE EXTINGUISHER: BY ANSUL NAMED "SENTRY 10" MODEL NO: AA10S PART NO: 436500 AGENT CAPACITY: 10 LBS. FORAY U.L. RATING: 4A:80B:C HEIGHT: 20.5 IN BRACKET: 435793
EGRESS PATH
1. IT IS THE RESPONSIBILITY OF THE TENANT OR TENANT'S G.C. TO FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS.
STORE AREA & EGRESS CALCULATING SPACE TYPE/ NAME
SF AREA
OCCUPANCY LOAD
TOTAL %
3. IT IS THE RESPONSIBILITY OF TENANT'S G.C. TO FIELD VERIFY EXISTING ELECTRICAL SERVICE AND TO MAKE ANY AND ALL MODIFICATIONS REQUIRED TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED ELECTRICAL SERVICE.
SALES AREA
1354 SF (GROSS)
SF / 60 = 23 OCCUPANT
75.0%
4. ENSURE THAT LAYOUT AND ALL FIXTURES COMPLY WITH LATEST CODE AND ADA REQUIREMENTS.
STOCK ROOM
396 SF (GROSS)
SF / 300 = 2 OCCUPANT
22.0%
RESTROOM
57 SF (GROSS)
SF / 300 = 1 OCCUPANT
3.0%
2. NOTHING SHALL BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THROUGH THE FLOOR OR ROOF DECK ABOVE.
5. FIRE EXTINGUISHER SHALL BE PLACED NO LESS THAN 12 INCHES ADJACENT TO THE DOOR FROM THE FORWARD APPROACH.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 ILLUMINATED EXIT SIGNAGE ABOVE; REF. RCP FOR FULL SPEC AND LOCATION
FE
EGRESS PLAN GENERAL NOTES:
TOTAL
1807 SF (GROSS)
26 OCCUPANTS
100 %
DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP
EXIT CAPACITY - PROVIDED
AREA: 1807 SQ.FT EXIT
WALL MOUNTED FIRE EXTINGUISHER
WIDTH
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
6'-0" CLEAR (72")
1
EXIT CAPACITY - REQUIRED OCCUPANTS WALL BASE AS SCHEUDLED 26 FINISHED FLOOR AS SCHEUDLED
4
SCALE: 1 1/2" = 1'-0"
5.2"
NOTE: TOTAL WIDTH REQUIRED LESS THAN MINIMUM REQUIRED EXIT WIDTH OF 32" CLEAR
TRAVEL DISTANCE ROUTE
FIRE EXTINGUISHER DETAIL
X INCHES/ OCCUPANT 0.20 (INCHES PER OCCUPANT)
DISTANCE
POINT A
38'- 0" (<75' MAX DISTANCE TO EXIT FROM TENANT SPACE TO EXIT)
POINT B
51'- 9" (<75' MAX DISTANCE TO EXIT FROM TENANT SPACE TO EXIT)
POINT C
67'- 8" (<75' MAX DISTANCE TO EXIT FROM TENANT SPACE TO EXIT)
EGRESS AND ACCESSIBILITY PLAN
G-003.00 SHEET 4 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
DURING DEMO FIRE SPRINKLER SYSTEM MUST BE BLANKED OFF PRIOR TO COMMENCING DEMOLITION MEP ENGINEER:
G.C. TO VERIFY SITE CONDITIONS OF EXISTING DEMISING WALL IN FIELD AND INCLUDE ALLOWANCE FOR GYP. BOARD ON DEMISING STUDS AS REQUIRED.
2
1
10
12
TYP.
NOTE: GC TO FURNISH & INSTALL TEMPORARY CONSTRUCTION GRAPHIC AT INTERIOR SIDE OF STOREFRONT, INCLUDING REMOVAL OF VINYL GRAPHIC AT TURNOVER. GC TO USE OWNER'S ARTWORK ONLY.
TYP. FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
7 3
9 10
TYP.
4 5 2 8
TYP. 12
+/- 3 1/4" V.I.F.
5
TYP.
11
TYP.
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
6
3
1 10
TYP.
9
10
10
1 1
1
TYP.
TYP. 3
DEMOLITION PLAN SCALE: 1/4" = 1'-0"
STAMP HERE:
HATCH & SYMBOL LEGEND HATCH / SYMBOL
DESCRIPTION
EXISTING PARTITION TO REMAIN
EXISTING TO BE DEMOLISHED
DEMOLITION PLAN GENERAL NOTES: 1. G.C. TO MAINTAIN THE INTEGRITY OF THE FIRE AND LIFE SAFETY SYSTEMS THROUGHOUT THE SCOPE OF THE WORK WITHIN THE PREMISES.
DEMOLITION PLAN KEY NOTES: 1
LEASE LINE
2
EXISTING 1-HR FIRE-RATED DEMISING PARTITION TO REMAIN; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH; COORD. W/ NEW WORK DWGS.
3
EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION
2. G.C. SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY, NEATLY AND IN A SYSTEMATIC MANNER. 3. ALL EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DAMAGE AND SHALL MAKE ADDITIONAL REPAIRS WITHOUT ADDITIONAL COSTS TO OWNER.
4
4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN. 5
5. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING MECHANICAL EQUIPMENT.
G.C. TO REPAIR OR REPLACE EXISTING THRESHOLD AT STOREFRONT ENTRY; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)
DATE: 08/20/2018 CHECKED BY: JSP
6
EXISTING AHU ABOVE TO REMAIN; COORD. W/ NEW WORK MEP DWGS.
7. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING PLUMBING FIXTURES.
7
EXISTING LINE VOLTAGE ELECTRICAL PANEL TO BE RELOCATED; G.C. TO RE-CIRCUIT AS REQUIRED; REF. NEW WORK ELECTRICAL DWGS.
8
EXISTING CONCRETE SLAB TO REMAIN; PREP FOR NEW RAISED FLOOR FINISH; COORD. W/ NEW WORK DWGS.
9
EXISTING SHAFT TO REMAIN; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE RATING AND PREP FOR NEW PAINT FINISH
10
EXISITNG ROUND CONCRETE COLUMN TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION AND PREP TO RECIEVE NEW POLISHED FINISH; REF. A-104
11
G.C. TO ALERT ARCHITECT IMMEDIATELY IF DIMENSIONS VARY ON SITE
12
EXISTING CONCRETE COLUMN TO REMAIN: GC TO PROTECT THROUGHOUT CONSTRUCTION
9. G.C. TO REMOVE EXISTING BASE, CEILING, AND FLOOR MOLDING, AS WELL AS SHELVING AND FIXTURES. 10. G.C. TO REMOVE AND DISCARD ALL ABANDONED LOOSE FIXTURES, CEILING AND LIGHT FIXTURES. 11. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING DEMOLITION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE. 12. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF THE BUILDING CODE. 13. THE GENERAL CONTRACTOR SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION.
PROJECT NO.: 218231
EXISTING STOREFRONT ENTRY DOOR AND HARDWARE TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION
6. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRICAL AND TELEPHONE PANELS.
8. G.C. TO REMOVE EXISTING FLOORING TO SUBFLOOR AND PREPARE SURFACE FOR NEW FLOORING.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
DEMOLITION PLAN
D-100.00 SHEET 5 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
1 10
4 7
3
4
4
TYP.
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
TYP.
10
7
5
TYP.
4 4
4
9
8
5
3
TYP. 1
TYP.
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
6
AHU
6
1
7 4
2
TYP.
4
TYP.
4
1
1
DEMOLITION REFLECTED CEILING PLAN
STAMP HERE:
SCALE: 1/4" = 1'-0"
HATCH & SYMBOL LEGEND HATCH
DESCRIPTION
EXISTING PARTITION TO REMAIN
EXISTING TO BE DEMOLISHED SYMBOL
DESCRIPTION
EXISTING UPRIGHT SPRINKLER HEAD; INDICATES EXISTING TO BE RELOCATED COORD. W/ NEW WORK DWGS AND APPROVED SPRINKLER DWGS.
DEMO REFLECTED CEILING PLAN GENERAL NOTES: 1. G.C. TO MAINTAIN THE INTEGRITY OF THE FIRE AND LIFE SAFETY SYSTEMS THROUGHOUT THE SCOPE OF THE WORK WITHIN THE PREMISES. 2. G.C. SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY, NEATLY AND IN A SYSTEMATIC MANNER. 3. ALL EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DAMAGE AND SHALL MAKE ADDITIONAL REPAIRS WITHOUT ADDITIONAL COSTS TO OWNER. 4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.
DEMO REFLECTED CEILING PLAN KEY NOTES: 1
LEASE LINE
2
EXISTING AHU ABOVE TO REMAIN; COORD. W/ NEW WORK MEP DWGS.
3
G.C. TO CONFRIM EXTENT OF 2HR RATED ACOUSTIC CEILING DEMOLITION REQ'D; COORD. WITH EXTENT OF NEW WORK SCOPE. G.C. TO MAINTAIN FIRE AND ACOUSTIC RATING AT EXISTING LANDLORD GYPSUM CEILING AND CONDUIT.
4
EXISTING LIGHTING AT GWB CEILING TO BE REMOVED BACK TO SOURCE U.N.O., TYP.
5
EXISTING OUTSIDE AIR DUCT ABOVE CEILING TO REMAIN; G.C. TO CLEAN, SERVICE, AND FINISH TO MATCH NEW CEILING COLOR; COORD. W/ NEW WORK RCP AND MEP DWGS.
6
EXISTING SUPPLY GRILLE AND ASSOCIATED DUCTING TO BE RECONFIGURED; COORD. W/ NEW WORK RCP AND MEP DWGS.
7
EXISTING SPRINKLER PIPES TO REMAIN; EXISTING UP RIGHT SPRINKLER HEADS TO BE REMOVED; COORD. SCOPE WITH NEW WORK RCP, MEP & APPROVED SPRINKLER DWGS. G.C. TO VERIFY WITH NEW WORK RCP THAT EXISTING LOCATION ALIGNS WITH OTHER CEILING FIXTURES PER A102.
5. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING MECHANICAL EQUIPMENT. HVAC RETURN GRILLE; INDICATES EXISTING TO REMAIN
6. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRICAL AND TELEPHONE PANELS. 7. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING PLUMBING FIXTURES.
HVAC SUPPLY GRILLE INDICATES EXISTING TO REMAIN
ACCESS PANEL; EXISTING TO REMAIN LIGHTS; EXISTING TO BE RELOCATED EXIT SIGN; EXISTING TO BE REMOVED AND RELOCATED EXITING SUPPLY DUCT; EXISTING TO REMAIN
8. G.C. TO REMOVE EXISTING FLOORING TO SUBFLOOR AND PREPARE SURFACE FOR NEW FLOORING.
8
EXISTING RATED ACCESS PANEL TO BE REMAIN
9. G.C. TO REMOVE EXISTING BASE, CEILING, AND FLOOR MOLDING, AS WELL AS SHELVING AND FIXTURES.
9
EXISTING EXIT SIGN TO REMOVED AND RELOCATED; COORD. W/ NEW MEP DWGS.
10
EXISTING CEILING OPENING; G.C. TO CONFIRM IF RATED ACCESS PANEL IS REQ'D. G.C. TO PATCH OPENINGS TO MATCH CURRENT CEILING FIRE AND ACOUSTIC RATING IF PANEL NOT REQ'D
10. G.C. TO REMOVE AND DISCARD ALL ABANDONED LOOSE FIXTURES, CEILING AND LIGHT FIXTURES. 11. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING DEMOLITION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE. 12. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF THE BUILDING CODE. 13. THE GENERAL CONTRACTOR SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
DEMOLITION REFLECTED CEILING PLAN
D-101.00 SHEET 6 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671 1
MEP ENGINEER:
3 FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM 5
TYP. 2
3
8
6 5
F
4
TYP.
TYP.
5
FACP
7
TYP.
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
9
1
5
TYP. 1
9
5
TYP.
TYP.
5
1
1
DEMOLITION POWER AND SIGNAL PLAN
STAMP HERE:
SCALE: 1/4" = 1'-0"
HATCH & SYMBOL LEGEND HATCH
DESCRIPTION
EXISTING PARTITION TO REMAIN EXISTING TO BE DEMOLISHED SYMBOL
T
TS
TM
FACP F
DEMOLITION GENERAL NOTES: 1. G.C. TO MAINTAIN THE INTEGRITY OF THE FIRE AND LIFE SAFETY SYSTEMS THROUGHOUT THE SCOPE OF THE WORK WITHIN THE PREMISES. 2. G.C. SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY, NEATLY AND IN A SYSTEMATIC MANNER.
DESCRIPTION WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE; EXISTING TO BE REMOVED
3. ALL EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DAMAGE AND SHALL MAKE ADDITIONAL REPAIRS WITHOUT ADDITIONAL COSTS TO OWNER.
SWITCH; EXISTING TO BE REMOVED
4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DOING AN ACCURATE SURVEY OF ALL EXISTING UTILITIES/ SERVICES INCLUDING PLUMBING, GAS, ELECTRICAL CIRCUITS, ETC. AS TO ENSURE THE DEMOLITION WILL NOT IMPACT THE STRUCTURE TO REMAIN.
THERMOSTAT; EXISTING TO BE RELOCATED; REF. MEP DWGS. TEMPERATURE SENSOR; EXISTING TO BE REMOVED AND REPLACED; REF. MEP DWGS. TIME-CLOCK; EXISTING TO BE REMOVED FIRE ALARM CONTROL PANEL; EXISTING TO REMAIN FIRE ALARM PULL STATION EXISTING TO BE RELCATED AND CONCEALED WITHIN WALL
DEMOLITION POWER AND SIGNAL PLAN KEY NOTES 1
LEASE LINE
2
EXISTING LINE VOLTAGE ELECTRICAL PANEL ABOVE TO BE RELOCATED; G.C. TO RE-CIRCUIT AS REQUIRED; REF. NEW WORK ELECTRICAL DWGS.
3
EXISTING CEILING OPENING; G.C. TO CONFIRM IF RATED ACCESS PANEL IS REQ'D; G.C. TO PATCH OPENINGS TO MATCH CURRENT CEILING FIRE AND ACOUSTIC RATING IF PANEL IS NOT REQ'D
4
EXISTING SWITCHING TO BE REMOVED U.N.O, TYP.
5
EXISTING WALL MOUNTED DUPLEX RECEPTACLE TO BE REMOVED.
6
EXISTING FIRE ALARM PULL STATION TO BE RELOCATED TO BE CONCEALED WITHIN THE WALL; COORD. W/ APPROVED FIRE ALARM DWGS.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018
5. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING MECHANICAL EQUIPMENT.
7
EXISTING FIRE ALARM CONTROL PANEL TO REMAIN; COORD. W/ APPROVED FIRE ALARM DWGS.
DRAWN BY: GR, RE, NK
6. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRICAL AND TELEPHONE PANELS.
8
REMOVE ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING BACK TO THEIR SOURCE
CHECKED BY: JSP
7. G.C. TO VERIFY LOCATION AND CONDITION OF EXISTING PLUMBING FIXTURES.
9
EXISTING ACCESS PANEL TO REMAIN
8. G.C. TO REMOVE EXISTING FLOORING TO SUBFLOOR AND PREPARE SURFACE FOR NEW FLOORING.
AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
9. G.C. TO REMOVE EXISTING BASE, CEILING, AND FLOOR MOLDING, AS WELL AS SHELVING AND FIXTURES. 10. G.C. TO REMOVE AND DISCARD ALL ABANDONED LOOSE FIXTURES, CEILING AND LIGHT FIXTURES. 11. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING DEMOLITION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE. 12. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF THE BUILDING CODE. 13. THE GENERAL CONTRACTOR SHALL LEAVE THE WORK AREA CLEAN AND SECURE AT THE END OF EACH WORKDAY. NO DEBRIS SHOULD BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ANY DEBRIS REMOVAL REQUIREMENTS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION.
DEMO POWER AND SIGNAL PLAN
D-102.00 SHEET 7 OF 27
ARCHITECT OF RECORD:
1
2
A-300.00
A-301.00 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
40' - 2 1/8" 3 7/8"
7 1/4" 1' - 4"
NOTE: VERIFY ALL DIMENSIONS WITH LOD AND V.I.F. GC ARE TO NOTIFY ARCHITECT'S OFFICE WITH ANY CONFLICTS PRIOR TO MATERIAL PURCHASE AND WORK COMMENCEMENT.
13' - 11 1/4"
14
4 1/4"
BIDDERS ARE REQUIRED TO HAVE SITE WALK THROUGH DURING BIDDING PROCESS. BIDDERS ARE TO COORDINATE THROUGH TENANT AND MALL MANAGER TO GAIN ACCESS. BIDDERS TO VERIFY SITE CONDITIONS FOR ALL DISCIPLINES PRIOR TO SUBMITTING PRICING.
3
14
V.I.F
3' - 10"
1
" '-4 R1
7
4' - 10 7/8"
3' - 10"
3' - 10"
FR 1
STORAGE CLOSET
FR 2
FR 3
04
05
06
07
1 A-307.00
3 3/4"
7' - 3 1/8" HOLD ADA RESTROOM 11
1 MEP ENGINEER:
14
14
2' - 0 5/8"
30 6
2
B
D 7
5
EX-01
3' - 4 1/8"
3
14 B 9
21
B
14
13
4' - 10"
9
4' - 10"
04
CAB
6' - 10"
A
4 1/4"
A 13
4' - 1 5/8"
DOOR BACK OF HOUSE
REF
14 A
21' - 5"
2
27 2
21' - 1 1/4"
3
7' - 3 5/8"
15
24 4
8' - 10"
6' - 6" FACP
STORAGE CLOSET
13
3' - 0"
01
6
03
A
HOLD
SALES
10
15
12
HOLD
1' - 6 5/8"
5
A-305.00 6
14
A
A-305.00 4
13
5
11' - 6"
1
B
10
14
14
2
ALIGN 2' - 6" C
5' - 4 3/4" HOLD
ADA FR
09
A-304.00 4
1' - 3"
13
FR 5
B
15
A-302.00 1
4
8
A-306.00 3
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
D
1 C
C
02
B VESTIBULE
DOOR
R1 '-4 "
4' - 11 1/8"
3' - 5 7/8"
13
14
42' - 4 1/4"
D
EQ
C
3' - 0"
R1 '-4 "
1' - 4 3/4"
2' - 0"
G
1' - 7"
EQ
3' - 0"
2' - 4 5/8"
1' - 7"
3' - 0"
1' - 3 1/8"
12
6' - 8 1/2"
A-301.00
FR 4 9 08
18
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
DOOR
21
4' - 8 1/2"
1' - 9 1/4"
4' - 6 3/4"
4
03
13 A-304.00 11
13
94 °
1
A
3
FITTING ROOM LOUNGE
5"
7 1/4"
G
20
4' - 6 1/4"
4
13
HOLD
5' - 0"
A-303.00 3
14
4' - 9 3/8"
12' - 7 1/4"
NOTE: DRYWALL CLOSURE MAINTAINED FROM FLOOR TO UNDERSIDE OF DECK ABOVE. ALL VOIDS, PENETRATIONS, SHAFT OPENING AND JOINTS ARE TAPED AND FIRE STOPPED AS REQ'D.
2
7 1/4"
26 17 19
4' - 6"
13
E
3' - 0"
" -4
NOTE: GC TO IDENTIFY POTENTIAL ACCESS PANEL LOCATIONS & COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION
14
13
12 13
1
14
11
02
29
B
10"
1'
2
A-304.00 10
21 14
LOUNGE
A 8 A-305.00 10 A
06
HOLD
R
ALL PENETRATIONS MADE TO LL'S RATED CONCRETE SLAB AND/OR RATED CMU WALL AND/OR RATED DEMISING WALLS ARE TO BE FIRE STOP WITH RATED SEALANT TO MAINTAIN THE RATING. ALL PENETRATES THRU RATED FLOOR AND WALLS ARE REQUIRED TO OBTAIN LL'S APPROVAL IN ADVANCE OF WORK COMMENCEMENT.
8
7
B
24
2' - 0 5/8"
2' - 8 1/2"
9 7/8" 1' - 11 1/4"
7
23
8' - 0"
C
5" 2' - 8 7/8"
NOTE: THE INTEGRITY OF ALL EXISTING FIRE SEPARATIONS SHALL BE MAINTAINED. GC TO APPLY MISSING FIREPROOFING WHERE APPLICABLE TO MAINTAIN REQ'D RATING
9' - 2"
HOLD
NOTE: INSTALL UL LISTED FIRE EXTINGUISHERS. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN CONFORMANCE WITH LOCAL FIRE CODE.
21
7' - 0 1/2"
86 °
D
2' - 0" DOOR
2' - 0"
NOTE: SEE MEP AND STRUCTURAL DRAWINGS FOR HVAC SYSTEM AND ADDITIONAL STRUCTURAL FRAMING
3
4
29
5
1
21
1
21
14' - 3 7/8" 1' - 6 1/4"
4' - 8 1/2"
2' - 8"
V.I.F.
F
ALIGN 28
2 14
ALIGN
13 29 4
22 16
13 A
4
1
13
2' - 0"
4
41' - 3"
5 7/8"
23
1"
05 7
HOLD
ALIGN
A
2
E
2' - 0"
11
V.I.F.
12
2' - 11"
25
20
2' - 8 5/8"
5' - 10" 7
4' - 10 5/8"
DOOR
LEASELINE TO LEASELINE
CONSTRUCTION PLAN
1
STAMP HERE:
SCALE: 1/4" = 1'-0"
HATCH & SYMBOL LEGEND HATCH / SYMBOL
DESCRIPTION
EXISTING PARTITION TO REMAIN
CONSTRUCTION PLAN GENERAL NOTES: 1. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLAN(S) AND EXISTING CONDITIONS. 2. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER.
NEW PARTITION
ROOM NAME
01
101
ROOM TAG
4. ALL EXISTING CONSTRUCTION, FITTINGS, EQUIPMENT, FINISHES ETC. TO REMAIN MUST BE PATCHED, REPAIRED, REFINISHED AND/OR REPLACED IN-PART OR IN-WHOLE; SO AS TO MEET A "LIKE NEW" AND FULLY OPERATIONAL CONDITION, TYP.
DOOR TAG; REF. A-601
5. ALL ABANDONED AND/OR UNUSED COMPONENTS CREATED OR EXPOSED DURING CONSTRUCTION, INCLUDING - BUT NOT LIMITED TO HVAC, CABLES, PIPING, WIRING, AND ASSOCIATED SUPPORTS AND/OR ATTACHMENTS SHALL BE REMOVED. REMOVED PIPES AND/ OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW SURFACES AND SHALL BE PROPERLY CAPPED OR PLUGGED. ALL ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING TO BE REMOVED BACK TO THEIR SOURCE.
PARTITION TYPE TAG; REF. A-600
A
3. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL OR COLUMN U.N.O. DO NOT SCALE DRAWINGS UNDER ANY CIRCUMSTANCES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER THE SCALE ON THE CONSTRUCTION DOCUMENTS.
6. G.C. TO USE 5/8" TYPE 'X' GYPSUM BOARD THROUGHOUT PROJECT.
CONSTRUCTION PLAN KEY NOTES: 15. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS.
1
LEASE LINE
19
SLOPE FLOOR TO DRIAN AT RESTROOM
2
G.C. TO INSTALL WINDOW GRAPHICS PRIOR TO CONSTRUCTION; COORD. W/ OWNER FOR GRAPHICS; OWNER TO SUBMIT GRPAHICS TO LANDLORD FOR APPROVAL PRIOR TO INSTALL
20
G.C. TO USE MOISTURE-RESISTANT TYPE "X" GYP. BOARD AT THE WALLS IN WET AREAS, INCLUDING RESTROOM AND AROUND THE VICINITY OF THE MOP SINK, TYP.
3
EXISTING 1-HR FIRE-RATED DEMISING PARTITION TO REMAIN; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH PARTITION AS REQ'D TO MAINTAIN A LEVEL 4 FINISH AND RESTORE ORIGINAL FIRE AND SOUND RATING; G.C. TO PREP DEMISING PARTITION FOR NEW PAINT FINISH
21
G.C. TO PROVIDE FRT PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND FIXTURE CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION
16. FIRE EXTINGUISHERS SHALL BE INSTALLED AS REQ'D BY LOCAL AUTHORITY HAVING JURISDICTION. 17. G.C. IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS AND STRUCTURE AND RESTORING TO FULL PROTECTIVE CAPACITY ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING FIREPROOFING CREATED OR EXPOSED DURING CONSTRUCTION,PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 18. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UL STANDARDS FOR THROUGH PENETRATION FIRESTOP SYSTEMS. THE G.C. SHALL SUBMIT SHOP DRAWING DETAILS THAT THE INSPECTOR MAY REQUIRE. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES CLEARLY DEFINED. 19. ALL DAMAGED, DETERIORATED, COMPROMISED OR MISSING THERMAL INSULATION - CREATED OR EXPOSED DURING CONSTRUCTION - SHALL BE RESTORED TO FULL CAPACITY. 20. G.C. SHALL THOROUGHLY CLEAN THE ENTIRE PREMISES PRIOR TO FINAL REVIEW, INCLUDING BUT NOT LIMITED TO THE FLOORS, MILLWORK, FIXTURES, EQUIPMENT, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. ALL SPLATTERS, SCRATCHES, MARKS. DEBRIS, AND DEFECTIVE MATERIALS OR PARTS SHALL BE REMOVED OR REPLACED. DELIVER PREMISES BROOM SWEPT CLEAN.
4
EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION
5
EXISTING THRESHOLD AT STOREFRONT ENTRY TO BE REPLACED; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)
6
EXISTING STOREFRONT ENTRY DOOR REMAIN; G.C. TO PROTECT THROUGHOUT DEMOLITION/CONSTRUCTION AND CLEAN TO DELIVER IN A 'LIKE NEW' CONDITION
22
G.C. TO PROVIDE PLASTEX POLYWALL WATERPROOF PANEL UP TO 48" AFF BEHIND AND AROUND MOPSINK, REF. ELEVATIONS; REF. A-104 FOR SPEC.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
23
NEW HIDDEN DOOR; COORD. W/ ELEVS. AND DETAILS FOR INSTALL HEIGHTS AFF.
PROJECT NO.: 218231
24
EXISTING CONCRETE COLUMN AND FINISH TO REMAIN; G.C. TO PROTECT DURING CONSTRUCTION.
25
G.C. TO PROVIDE POWDER COATED SHEET METAL, TIGHT WRAP EXISTING BULDING PIPING; FINISH TO MATCH PT-02
CHECKED BY: JSP
26
EXISTING 2-HR RATED SHAFT ENCLOSURE; G.C. TO MAINTAIN EXISTING FIRE AND SOUND RATING; WHERE DAMAGED G.C. TO PATCH AND REPAIR AS REQ'D TO RESTORE ORIGINAL FIRE AND SOUND RATING
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
7
EXISITNG ROUND CONCRETE COLUMN TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION AND PREP TO NEW POLISH AND GRIND FINISH; REF. A-104
8
EXISTING AHU ABOVE TO REMAIN; COORD. W/ MEP DWGS.
27
BUILT IN CABINETRY, REF. MILLWORK DETAILS ON SHEET A-400
9
NEW LOCATION OF EXISTING ELECTRICAL PANEL; COORD. W/ MEP DWGS.
28
EXISTING SHAFT ENCLOSURE AND ACCESS PANEL TO REMAIN; GC TO MAINTAIN REQ'D FIRE RATING
9. METAL STUDS SHALL EXTEND UP TO THE DECK ABOVE WHERE NOTED AND APPLICABLE.
10
EXISTING FIRE-ALARM CONTROL PANEL; COORD. W/ MEP DWGS.
29
PERIMETER BASEBOARDS LOCATED BELOW DISPLAY PLATFORM; COORD. W/ MEP DWGS.
10. PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADERS AND JAMBS, AND AS REQUIRED TO MAKE ASSEMBLY RIGID.
11
EXISITING BUILDING PIPES TO REMAIN; G.C. TO PROVIDE ACCESS PANEL IN NEW BUILT PLATFORMS IF REQ'D.
30
G.C. TO BUILD OUT WALL TO ALIGN W/ FACE OF FIRE ALARM DEVICES AND CONCEAL EXPOSED CONDUIT
A101
11. G.C. TO COORD. NEW WORK W/ FIXTURE PLAN. REF. A-101 FIXTURE PLAN FOR FIXTURE INFORMATION.
12
1 A101
12. G.C. SHALL SUPPLY AND INSTALL PROPER AND ADEQUATE BLOCKING TO SUPPORT ALL OWNER SUPPLIED AND MILLWORK APPLIED/INSTALLED ITEMS FOR FIRM, LEVEL, AND SECURE INSTALLATION OF SUCH ITEMS ON WALLS, COLUMNS, ETC. IF REQUIRED BY CODE ALL SUCH BLOCKING AND SUPPORTS SHALL BE FIRE RETARDANT TREATED TO MEET SUCH REQUIREMENTS. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE IN COMPLIANCE WITH IBC SECTION 2304.9.5.
EXISITING BUILDING SIAMESE CONNECTION TO REMAIN; G.C. TO PROVIDE ACCESS PANEL IN NEW BUILT PLATFORMS IF REQ'D.
13
NEW PARTITION TO EXISTING SOUND RATED CEILING ABOVE; REF. A-600 FOR PARTITION SCHEDULE
14
NEW PARTIAL HEIGHT PARTITION; REF. A-600 FOR PARTITION SCHEDULE
15
NEW DOOR, FRAME, AND HARDWARE; REF. A-601 FOR DOOR AND HARDWARE SCHEDULES
13. FOR ALL WOOD MEMBERS REQUIRED BY CODE TO BE FIRE-RETARDANT TREATED, PROVIDE PRESSURE IMPREGNATION WITH FIRE-RETARDANT CHEMICALS TO PROVIDE UL PRS FIRE HAZARD CLASSIFICATION. ALL SUCH WOOD MEMBERS SHALL BE IDENTIFIED WITH A UL LABEL.
16
NEW MOP SINK, FAUCET, AND SHELF-MOUNTED WATER HEATER ABOVE; COORD. W/ MEP DWGS.
17
NEW RESTROOM W.C. AND LAVATORY; COORD. W/ MEP DWGS.
14. G.C. TO COORD. NEW WORK W/ RCP.; REF. A-102 RCP FOR SOFFIT / LIGHTING INFORMATION.
18
NEW FLOOR DRAIN AT RESTROOM; COORD. W/ MEP DWGS; VERIFY EXACT LOCATION IN FIELD
7. ALL OUTSIDE CORNERS AT DRYWALL PARTITIONS AND FURRING TO HAVE METAL CORNER BEADS. TAPE, PLASTER, AND SAND SMOOTH. MAINTAIN A LEVEL 4 FINISH AT ALL WALL LOCATIONS, TYP. 1 A101
1
ELEVATION TAG
DETAIL SECTION TAG
DETAIL CALLOUT TAG
8. ACCESS PANELS IN WALL / CEILING FOR PLUMBING, MECHANICAL, ELECTRICAL ACCESS SHALL BE FLUSH FRAMELESS SQUARE CORNER GYP. BOARD PANELS, SEE RCP A-102 FOR SPECIFICATION.
DATE: 08/20/2018 DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT
CONSTRUCTION PLAN
A-100.00 SHEET 8 OF 27
ARCHITECT OF RECORD:
HATCH & SYMBOL LEGEND SYMBOL
DESCRIPTION 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
EXISTING PARTITION TO REMAIN
NEW PARTITION ROOM NAME
04
05
SH.06
FURNITURE / FIXTURE / EQUIPMENT TAG
WALL MOUNTED SHELVING BRACKET
16"
EMPLOYEE LOCKER DISPLAY BUNK DOUBLE HANG
12"W x 18"D x 72"H 54" L X 24" D X 95" H
F.02
DISPLAY BUNK SHELF HANG
54" L X 24" D X 95" H
F.C.
BS BST
WALL MOUNTED STANDARD TOP TRACKS BAR STOOL WALL MOUNTED STANDARD
VARIES 15"Ø x 27"H 84"H
CB
COAT HANG BAR
20"L x 1 3/8"D x 2 3/4"H
CF
2-DRAWER LOCKING FILING CABINET
16-1/4" x 15-3/4" x 29" H
CH-01 CH-2 CH-03 CPT-01 DSK
LARGE TABLE SMALL ROUNDER
F.21 F.23 F.24 F.25 F.26 FB-01
ROUND TABLE WITH TULIP LEG DISPLAY PLATFORM STANDING RACK MONDRIAN SCREEN CONCIERGE DESK FITTING ROOM CURTAIN
FDSK GB
BOH DESK ADA GRAB BARS
HS
HANGING SYSTEM - MERCHANDISING TRACK
KB MQ MR
KEY BOX MANNEQUIN RESTROOM MIRROR
24"W X 38"L X 63"H 24"W X 38"L X 63"H 90" L X 23.25" D X 83" D 42"L x 20"W x 17"H 72"L x 36"W x 30"H 36" Ø x 15"H
F.C. TBD
42"Ø x 30"H 32" D X 28.25" H (LENGTH VARIES) REF. PLANS 1"SQ. X 62"L X 63"H 108" H (LENGTH VARIES) REF. PLANS REF. PLANS REF. PLANS 35 3/8'W x 19 5/8"H 18"L, 36"L, 42"L
16"D (LENGTH VARIES)
SH.01
MOBILE SHELVING
SH.03
SHELVING
1' 10 3/4"W x 2'D x 9'H
SH.04
SHELVING
1'6"W x 2'D x 9'H
5W' x 2'D x 9'H
RECESSED PAPER TOWEL DISPENSER
19"H X 13"W X 4 1/4"D
TDSH
TELE/DATA SHELF
19"L x 14 3/4"D x 4"H
TPH
TOILET PAPER HOLDER
2 1/2"W X 3"D X 6"H
UH
UTILITY HOLDER
10"L x 4"D x 2 3/4"H
G.C.
TBD
OWNER (MODCLOTH)
WHITE METAL
G.C.
BRASS
BONOBOS G.C.
WHITE
G.C.
TBD TBD TBD CPT-01
TBD OWNER (MODCLOTH) OWNER (MODCLOTH) OWNER (MODCLOTH)
WHITE
G.C.
WHITE
G.C.
WD-01/MT-01
F.C.
WD-01/MT-01
F.C.
MT-01 MT-01 WD-01/MT-01
F.C. F.C. F.C.
WD-01
F.C.
WD-02
F.C.
ADA RESTROOM
1
FINISH: WHITE
7 1 4 1 1
FINISH: MT-01
2 1
G.C.
1 2 2 2 1 6 1 1
G.C. G.C.
BLACK TBD
G.C. OWNER (MODCLOTH)
BRASS FRAME
G.C.
WHITE METAL
G.C.
WHITE METAL
G.C.
WHITE
G.C.
WHITE
G.C.
TBD
G.C.
BRUSHED, POLSHED BRASS
G.C.
BLACK
G.C.
BRONZE
G.C.
DESCRIPTION BOH REFRIGERATOR
FINISH: WHITE METAL
7
BOH MOBILE SHELVING
1
BOH MOBILE SHELVING
1
FR SHELVING
1
RECESSED INTO WALL
1
LOCATED ON TELE/DATA BOARD
1
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS LOCATED BY MOPSINK
DIMENSION 20 5/8"W x 20 7/8"D x 32 3/4"H
MANUFACTURER DANBY
MODEL DCR044A2BDD
RESPONSIBILITY G.C.
QUANTITY NOTES / REMARKS 1 COORD. INSTALL WITH BOH SHELVING
QUANTITY NOTES / REMARKS 1 G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. 1 COORD. W/ MEP DWGS. GOLD POLISH FINISH 1 G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS.
PLUMBING SCHEDULE TAG PL.01
DESCRIPTION RESTROOM SINK
DIMENSION 20"W X 18"D
MANUFACTURER KOHLER
MODEL K-2084
RESPONSIBILITY G.C.
PL.02 PL.03
RESTROOM SINK FAUCET RESTROOM TOILET
2.2"W X 6.5"D X 6.5"H 17 5/8"W X 28 3/4"D X 30 3/4"H
MAC FAUCET KOHLER
FA444HD-17 CIMARRON K-3609
G.C. G.C.
PL.04 PL.05
SERVICE SINK SERVICE SINK FAUCET
21"W X 21 1/2"D X 44 1/2"H 8" SPREAD
TSA-1MOP B-0674-RGH
G.C. G.C.
PL.06 PL.07
WATER COOLER FLOOR DRAIN
TURBO AIR T&S BRASS AND BRONZE WORKS, INC. QUENCH MIFAB
750 F1100-2, (POLISHES BRASS TYPE 5 INCH ONLY)
G.C. G.C.
13 1/2"W x 14 1/2"D x 40 1/2"H 6"Ø STRAINER
1 1
FR 4
FR 5
08
09
A.04
4
4' - 6"
1' - 8"
MQ
CAB
F.03
14
COORD. W/ MEP DWGS. RECESS FLOOR DRAIN INTO FLOOR, G.C. TO TRENCH AS REQUIRED
SH.04
SH.03 LOCKER
EL 14
14
SH.01
SH.01
4' - 3 5/8"
14 1 14
F.01
CH-01
CH-01
F.24
11
11
F.24
HS
13
SH.01
SH.01 SH.01
2
PL.04 PL.05
12 UH
HS MQ
MQ
15' - 10 7/8"
1
FDSK
F.18
MQ
HS
CF
BACK OF HOUSE
SH.01
4
F.26
MQ
WC
5
REF
01 4' - 7"
13
6
CH-2 REF-2
1 HS
BS PL.06
SALES
4' - 0"
TDSH
9
F.23
MQ
DSK
10
A.06
F.18
F.04
KB
FB-01 F.12 ADA FR
11
2' - 8"
13
7
A.05
CH-01
F.02
STORAGE CLOSET
FACP
7
F.01
BY S&L DESIGN; FINISH MT-01 FINISH: MT-01, GL-01 FINISH: WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS WD-01 FINISH: MT-01, WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: WD-01 FINISH: PT-01B; BUILT IN WINDOW DISPLAY (L-01) FINISH: MT-01 FINISH: MT-01, GL-03 FINISH: WD-01 G.C. TO COORD. INSTALLATION W/ BRAD JOBE; CURTAIN SUSPENDED FROM RODS AND RINGS
EQUIPMENT SCHEDULE TAG REF-2
9
F.25
1
1
7
FB-01
A.06
MQ
REFINISHED VINTAGE CHAIR NOT INSET; REMOVABLE AREA RUG COORD. INSTALL WITH BOH REFRIGERATOR (REF-2); REF. ELEVATIONS GRAY FINISH: MT-01; WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS FINISH: MT-01; WD-01; REF. FIXTURE PACKAGE FOR MORE DETAILS
1
1 23 1
9
4
MQ
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS CEILING RECESSED MERCHANIDISING TRACKS; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND POWDERCOAT TO MATCH ADJ. FINISH COORD. W/ TELE/DATA BOARD G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS FINISH: WHITE METAL
19
WHITE
G.C.
1
4 2 1 1
TBD
BLACK
FINISH: WD-01 FINISH: WHITE METAL
1
BROWN-BLACK VIBRANT FRESH GOLD
THE CONTAINER STORE
2 2
1 2
IKEA KOHLER
VIDEO MOUNT PRODUCTS GATCO
FINISH: WHITE METAL
4
MQ
FINISH: WHITE METAL
1
FB-01
CH-01 A.06
F.21
OWNER (MODCLOH)
THE CONTAINER STORE THE CONTAINER STORE PIPP MOBILE STORAGE PIPP MOBILE STORAGE PIPP MOBILE STORAGE FAUCETSINHOME
WALL MOUNTED VENTILATED SHELF
WHITE METAL
2
F-01
MMF INDUSTRIES TBD REJUVENATION
SH16
G.C.
F.C. G.C. F.C. F.C. OWNER (MODCLOTH)
11.7"H x 7.9"W x 3.6"D 3/4 TORSO 24"W X 36"H 12"D (LENGTH VARIES)
WHITE METAL
WD-03/MT-01 CC0949 MT-01 BRASS/GLASS TBD
ARAKAWA
WALL MOUNTED VENTILATED SHELF
G.C.
TBD G.C. F.C. F.C. TBD BRAD JOBE
REF. PLANS; G.C. TO CUT LENGTHS IN FIELD AS REQ'D
SH12
TD
F.C. F.C. F.C. F.C.
WHITE METAL
CH-03
CPT-01
7' - 3 1/2"
F.18 F.20
FREE-STANDING HANG RACK GLASS FIXTURE ADA BENCH
19" H X 17" Ø -30" W X 26" D 116"W x 108"L 42"L x 24"D x 34"H
F.C.
3' - 1 1/4"
MQ MQ
4' - 9 3/8"
F.03 F.04 F.05 F.12
FITTING ROOM POUF EMPLOYEE CHAIR VINTAGE CHAIR AREA RUG WALL MOUNTED DESK
POLISHED BRASS
MIN
4
14
12
1
F.23
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
B16
F.C./G.C.
3' - 0"
HS
8' - 8"
EL F.01
THE CONTAINER STORE THE CONTAINER STORE THE CONTAINER STORE TBD THE CONTAINER STORE THE CONTAINER STORE - UMBRA THE CONTAINER STORE TBD TBD TBD TBD THE CONTAINER STORE ULINE F.C.
BRASS
SH.05
VESTIBULE
4' - 0"
12"
F.C.
03
F.20
4' - 6"
WALL MOUNTED SHELVING BRACKET
F.C.
POLISHED BRASS
A.01
CH-03 11
CB
7
1' - 7"
30" W X 78" H
F.C.
CH-03
CH-03
GB
9
FITTING ROOM LOUNGE
A.03
F.03
A.02
TELE/DATA
F.C.
POLISHED BRASS
8
7
PL.07
4
1' - 6"
30" W X 78" H
F.C./G.C.
MIN
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
2' - 0"
F.C.
BRASS
F.23
4
10
FB-01
2' - 0"
1"W X 1"H x 3"D
F.C./G.C.
MQ
FB-01
TD
TPH
4 F.27 3' - 0"
A.06
2' - 0"
F.C.
BRASS
02
13
A.06
MR
3' - 6"
F.C.
30" W X 78" H
B12
BR
11
3
PL.02
2' - 0"
78" W X 58" H
F.C./G.C.
QUANTITY NOTES / REMARKS 1 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 1 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 1 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 6 FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. 20 FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. 6 FINISH: GL-01, MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; MIRROR (GL-01) BY G.C.; VERIFY DIMS. IN FIELD AND SECURE TO FRAME WITH MASTIC 1 FINISH: MT-01; REF. FIXTURE PACKAGE FOR MORE DETAILS; REF. ELEVATIONS FOR MOUNTING HEIGHTS, TYP. 2 FINISH: WHITE METAL
CH-01
2' - 0"
F.C.
BRASS
RESPONSIBILITY
FB-01
CH-01
18' - 0"
FITTING ROOM HANG BAR SHORT
3
2' - 8"
A.07
FITTING ROOM MIRROR
1
4' - 2 5/8"
A.06
VALET PEG
46"W x 93"H x 2 1/2"D
FINISH
A.06
9
MIN.
A.05
FITTING ROOM HANG BAR
MANUFACTURER F.C.
LOUNGE
MQ
3' - 0"
A.04
LARGE MIRROR
F.05
MQ
DIMENSION 24" W X 78" H
CH-01
4
15' - 8"
A.03
3-WAY ARCHED MIRROR
07
PL.03 14
2' - 8"
A.02
06
ADA RESTROOM
12
HS
FIXTURE SCHEDULE DESCRIPTION FITTING ROOM LOUNGE MIRROR
FR 3
MEP ENGINEER:
MQ
TAG A.01
FR 2
1' - 10 3/4" 2' - 0"
X.01
ROOM TAG
1
STORAGE CLOSET
1' - 10 3/4"
01
4
FR 1
11
F.23
13
MQ
MQ
17' - 2 1/2"
13
F.23
11
8' - 1 5/8"
FIXTURE PLAN
STAMP HERE:
SCALE: 1/4" = 1'-0"
FIXTURE PLAN GENERAL NOTES:
FIXTURE PLAN KEY NOTES:
1. REFER TO FINISH SCHEDULE A-104 FOR FINISH DESCRIPTIONS AND SPECIFICATIONS.
1
LEASE LINE
2. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES.
2
NEW MOP SINK AND FAUCET; COORD. W/MEP DWGS.
3. G.C. & F.C. TO COORDINATE CONSTRUCTION & INSTALLATION MATERIALS, METHODS, AND SCHEDULING OF FIXTURES.
3
NEW RESTROOM TOILET AND SINK; COORD. W/MEP DWGS.
4
G.C. TO PROVIDE FIRE RATED PLYWOOD IN-WALL BLOCKING AS REQUIRED FOR ALL PERIMETER MILLWORK FIXTURES; COORD. W/ ELEVATIONS AND MILLWORK CONTRACTOR; REF. CONSTRUCTION DETAILS FOR MORE INFORMATION.
4. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS. 5. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP. 6. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING. G.C. TO COORDINATE WITH SHOP DRAWINGS TO BE PROVIDED BY THE FIXTURE CONTRACTOR. 7. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS. 8. FINISHES TO BE FIRE RATED AS REQUIRED BY STATE/LOCAL BUILDING CODES. 9. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND MILLWORK. COORDINATE CONSTRUCTION DETAILS AND DIMENSIONS WITH FIXTURE PLANS AND FIXTURE SHOP DRAWINGS.
5
6
7 8
13. THERE ARE NO POINT-OF SALES OR SERVICE COUNTERS IN THIS STORE. MODCLOTH STORES ARE DESIGNED AND OPERATE AS SHOWROOMS. MO MERCHANDISE IS SOLD ON LOCATION.
DATE: 08/20/2018
NEW DRAPERY PANEL INSTALLED ON RODS AND RINGS AT FITTING ROOMS; B.O. OPENING TO THE PEAK OF ARCHED TRANSITION AT 8'-3" AFF; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS
CHECKED BY: JSP
3-WAY ARCHED MIRROR (A.02) W/ LIGHTING BEHIND MIRROR FRAME; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; F.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND RCP
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
MIRROR (A.01) W/ LIGHTING ON BOTH SIDES OF THE FRAME; B.O. FRAME MOUNTED @ 9" AFF; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; F.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS.
10
LARGE MIRROR (A.03) LOCATED IN LOUNGE; B.O. FRAME MOUNTED @ 9" AFF; MIRROR FRAME MUST BE ON LOW PROFILE METAL Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION; F.C. TO PROVIDE MIRROR (GL-02). CONFIRM FIELD DIMENSIONS AND SECURE WITH MASTIC TO FRAME BY F.C.; PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS.
11
MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD, REF. A-102B FOR DIMENSIONS; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.
12
NEW HIDDEN DOOR AND FRAME FURNISHED AND INSTALLED BY G.C.; ALL HARDWARE AND FRAMING TO BE CONCEALED FROM ENTRY SIDE OF DOOR; REF. DOOR DETAILS A-602
13
NEW STOREFRONT DISPLAY PLATFORM (F.23); FURNISHED AND INSTALLED BY G.C.; FINISH; PT-04 & L-01
14
NEW B.O.H. PIPP SHELVING; G.C. TO COORD. INSTALLATION W/ MANUFACTURER; G.C. TO VERIFY SITE DIMENSIONS AND SUBMIT A PROPOSED LAYOUT FROM FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION.
11. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS.
PROJECT NO.: 218231
NEW TELE/DATA BOARD BY G.C. (3/4" FRT PLYWOOD) MOUNTED TO WALL AT B.O.H. AND PAINTED TO MATCH ADJ. FINISH
9
10. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.
12. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES.
NEW B.O.H. CONTAINER STORE ELFA SHELVING; G.C. TO COORD. INSTALLATION W/ MANUFACTURER; G.C. TO VERIFY SITE DIMENSIONS AND SUBMIT A PROPOSED LAYOUT FROM THE CONTAINER STORE HEADQUARTERS FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT
FIXTURE PLAN
A-101.00 SHEET 9 OF 27
ARCHITECT OF RECORD:
HATCH & SYMBOL LEGEND HATCH / SYMBOL
FR 1
STORAGE CLOSET
MIRROR NICHE
FR 2
FR 3
ADA RESTROOM
02
04
05
9' - 0" AFF
06
07
11
10' - 0" AFF
9' - 0" AFF
12' - 10 3/4" AFF
GYP. CEILING
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
GYP. CEILING
GYP. CEILING
EX'G CEILING
PT-01C
GYP. CEILING
GYP. CEILING
GYP. CEILING
WC-03
PT-01C
PT-01C
PT-01C
PT-01C
PT-01C
DESCRIPTION
EXISTING PARTITION TO REMAIN
IN-CEILIGN FIRE RATED WOOD BLOCKING WHERE REQ'D
NEW PARTITION
LOUNGE CLG
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
11' - 0" AFF
ROOM NAME
GYP. CEILING
01
25
1
14
21
14
34
1
14
PT-01C
FINISH SYMBOL
DESCRIPTION
MANUFACTURER
SHOPPER TRACK W/ STEM KIT
TC1
SHOPPER TRACK - SECONDARY UNIT
MD
WIRELESS MOTION DETECTOR WIRELESS DOOR CONTACT
ST ST CLG
COORD. W/ VENDOR DWGS (ADT SECURITY)
WHITE
FIRE ALARM STROBE WALL MOUNTED
COORD. W/ APPROVED FIRE ALARM DWGS
FIRE ALARM STROBE CEILING MOUNTED
COORD. W/ APPROVED FIRE ALARM DWGS
WHITE WHITE
REF. APPROVED FIRE ALARM DWGS
WHITE
REF. APPROVED FIRE ALARM DWGS
1
S
WALL MOUNTED SPEAKER REF. ELEVATIONS FOR MOUNTING HEIGHT
COORD. W/ VENDOR DWGS (PLAYNETWORK)
WHITE
NOT USED
SMOKE DETECTOR
COORD. W/ MEP DWGS COORD. W/ MEP DWGS
WHITE
REF. MEP DWGS
CONCEALED SPRINKLER HEADS WITH COVER TO MATCH ADJACENT FINISH
COORD. W/ APPROVED SPRINKLER DWGS
WHITE
REF. SPRINKLER DWGS
MATCH ADJ. FINISH
COORD. W/ APPROVED SPRINKLER DWGS
HVAC RETURN GRILLE; SIZED AS PER MECHANICAL DWGS; PAINTED TO MATCH CLG COLOR
36
28
10
F-1
R-1
F-1 TYP. F-1
BRASS TRANSITION 23
R-1
R-1
COORD. W/ MECHANICAL DWGS
WIRELESS ACCESS POINT
COORD. W/ VENDOR DWGS (BANDWAVE)
ACCESS PANEL (G.C. TO MATCH REQ'D FIRE RATING)
MATCH ADJ. FINISH WHITE
P-5
26
LS
ACTIVAR MODEL TMW OR APPROVED EQUIVALENT; PAINT TO MATCH ADJACENT FINISH
MATCH ADJ. FINISH
COORD. W/ SIGNAGE SHOP DWGS
PER VENDOR
COORD. W/ MEP DWGS
GYP. CEILING
DC
R-6 WC-05
14 LS
19 6
R-3
R-3
CH-1
TYP.
17
12' - 10 3/4" AFF
21
EX'G GWB
EM-1 CLG CLG
J
TR-1 F-1
WINDOW DISPLAY
12' - 10 3/4" AFF
TYP. 10
HANGING SYSTEM - MERCHANDISING TRACK
ARAKAWA - CRB -1800A; (CRC-1800A ACCEPTABLE, IF NOT IN STOCK); MATCH ADJ. FINISH
DESCRIPTION CHANDELIER
REF. SHOP DWGS
GB HS
MODEL TBD
FINISH BRASS
W/V 100W
P-5
CHANDELIER
CH-3
DECORATIVE LIGHTING INSTALLATION
EM-1
SURFACE RECESSED EMERGENCY LIGHT
EX-1
EX-2
EX-3
F-1
RECESSED CEILING MOUNTED EXIT SIGN AT SALES
RECESSED WALL MOUNTED EXIT SIGN AT SALES WALL MOUNTED EXIT SIGN AT BOH
TBD
TBD
BRASS
100W
REF. MEP DWGS REF. A -101
TBD
TBD
BRASS
100W
10
EVENLIGHT-APERION
APR-25-LC-UI
WHITE
25W
5
CONTECH
REXA-SF-R-EM-C-P
WHITE
120/277 V
1
CHANDELIER PROVIDED BY OWNER (MODCLOTH); G.C TO PROVIDE LAMPS: (10) WARM WHITE (2700K) 9W LED A19 BULBS
CHANDELIER PROVIDED BY OWNER (MODCLOTH); G.C TO PROVIDE LAMPS: (10) WARM WHITE (2700K) 9W LED A19 BULBS G.C. TO PAINT TO MATCH ADJ. FINISH
X-RW-1-C-W
ENCORE
LSE-8-R-1
WHITE
WHITE
3
120/277 V
1
P-5
4
GYP. CEILING
21
PT-01C
FL-2
CLOSET
22
13 12' - 10 3/4" AFF
17
R-6
LS
21
EX-3
EX'G GWB
9
PT-01C
TYP.
WC-07
P-5
LS
TRANSITION
25
7' - 6" AFF
TYP.
GWB. PT-01C
R-3
ADA FR
20
10
TYP. 3' - 3"
3' - 3"
FL-1
EM-1
9' - 0" AFF GYP. CEILING
15
R-1 J 35
R-3
CLG
16
PT-01C
16
09
AHU
R-3
9' - 0" AFF R-1
GYP. CEILING
R-1 15
F-1 36 21
GYP CEILING
18
LIGHT COVE
13' - 1 1/4" AFF GYP. GWB PT-01C
22 13
R-3
1
21
R-3
BOH
FL-1 EM
TYP.
14 FL-1
TYP.
12' - 10 3/4" AFF
F-1 D D
F-1 LS
F-1
EX'G GWB CLG CLG
7
36
TYP.
TC2
21
CLG
TYP.
14
PT-01A
3
WH 14
F-1
CLG
F-1 TR-1
GB CLG
CLG
F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1
F-1
J
CLG
F-1 F-1 TR-1 1
NO HARD CONNECTION TO LL'S SLAB OR ACOUSTIC CEILING. ANY PENETRATION MADE TO ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATION AND SEAL WITH FLEXIBLE CAULK TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS PANEL REQUIRED IN ADDITION TO THE ACCESS PANEL ALLOCATED IN SPACE, G.C. IS TO MAKE THE CONNECTION AND THEN PATCH BACK IN WITH TWO LAYERS OF THE TYPE'X' GYP. BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING
R-3
PT-01C
2
20
TYP.
R-3
FR 5
1
S
CLG
CLG
14
CLG GB
CLG
J
F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 TR-1
12
10 TYP.
GB
CLG
J F-1 TR-1
CLGCLG
F-1
F-1 7
27
REFLECTED CEILING PLAN
STAMP HERE:
SCALE: 1/4" = 1'-0"
SINGLE FACE, RECESSED CEILING MOUNTED
REFLECTED CEILING PLAN GENERAL NOTES: ENCORE - SUPER UNIVERSAL
14
TYP.
R-1
S
R-3
01
QUANTITY COMMENTS 1 CHANDELIER PROVIDED BY OWNER (MODCLOTH); G.C TO PROVIDE LAMPS: (10) WARM WHITE (2700K) 9W LED A19 BULBS
1
OS
TYP.
18
FL-1 EM
R-3
TYP.
F-1 F-1
GENERAL FINISH/FIXTURE NOTES CH-2
17
19
FL-1
19
SALES
PT-01C MANUFACTURER TBD
TYP.
38
F-1
LIGHTING SCHEDULE TAG CH-1
9' - 0" AFF
26
TYP.
12
39
R-2
PT-01C
1
POWER COAT TO MATCH ADJ. FINISH
EX-2
R-6
11' - 0" AFF
HS
VESTIBULE
4
5
TYP.
J 35
24
CLG
WC-06
(PLASTER)
PL-01
16
5 4
21
TC1
EX-1
AS REQ'D
BORDER: 22; FINISH: 26
P-5
11
CLG
8 DC
EX'G GWB
29
TYP.
36
9' - 0" AFF
1
P-5
14
PT-01C
REF. MEP DWGS
TYP.
GYP. CEILING
21
CH-3
CH-3
5
4
CLG
08
REF. MEP DWGS
P-5
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
ARCHED FR TRANS TYP.
TYP.
EM-1 P-5
24
7' - 6" AFF
22
P-5
EX-2 MD CLG
TYP.
CLG
TYP.
BRASS
REF. SPRINKLER DWGS
MATCH ADJ. FINISH
29
EM-1
BRASS
CH-3
LS
R-1
F-1 TR-1
17
19 TYP.
CH-3
19 R-5
R-5
23
5
S
CLG
R-1
19
P-6
R-6
P-5
4
TYP.
37
TL-1
F-1
S
26
CH-2
TYP.
EM-1 EX-2
32
37
4
19
16
R-1
32
LS WC-04
17
29
CH-3 28
LS
R-1
12
P-5
4
S1 J
5
R-6 P-5
P-5
36
35
CLG
LS WC-03 R-6
P-5
5
R-1
S1
4
FL-1
R-1
17
TYP.
LS
PT-01C
NOT USED
HVAC SUPPLY GRILLE; SIZED AS PER MECHANICAL DWGS; PAINTED TO MATCH ADJ COLOR
1" TAPED-IN LINEAR SLOT DIFFUSER
R-6
ENTRY
UPRIGHT SPRINKLER HEADS
LS
R-6
33
GB
BRASS
REF. MEP DWGS
WHITE
R-6 4
14 R-1
7
9' - 0" AFF
9' - 0" AFF
TYP.
P-5 21
F-1
TRANSITION
R-6
FR 4
OCCUPANCY SENSOR CEILING MOUNTED
REMOTE DRIVER FOR STOREFRONT SIGNAGE
TYP.R-6
R-1
HS
PT-01A
REF. APPROVED FIRE ALARM DWGS
WHITE
36
CLG
F-1
GYP. CEILING
REF. APPROVED FIRE ALARM DWGS
WHITE
D
F-1
J
(CURVED) 12' - 10 3/4" AFF
5
COORD. W/ VENDOR DWGS (PLAYNETWORK)
WA
PT-01C
03
1 PAIR
CEILING RECESSED SPEAKER
OS
F-1
FR LOUNGE DOME
1
S
SD
EXG' GWB
31
P-5
P-5 LS WC-02
WC-01
CLG
F-1
1
PAINT TO MATCH ADJ. FINISH
COORD. W/ APPROVED FIRE ALARM DWGS
TR-1
1
WHITE
COORD. W/ APPROVED FIRE ALARM DWGS
FIRE ALARM SPEAKER/STROBE CEILING MOUNTED W/ STEM KIT
S
WHITE
COORD. W/ VENDOR DWGS (ADT SECURITY)
FIRE ALARM SPEAKER/STROBE WALL MOUNTED
CLG
COORD. W/ VENDOR DWGS (RETAIL NEXT)
12' - 10 3/4" AFF QUANTITY
WHITE
COORD. W/ VENDOR DWGS (ADT SECURITY)
SURFACE MOUNTED SECURITY CAMERA; REF. ELEVATIONS FOR MOUNTING HEIGHT S
FINISH
COORD. W/ VENDOR DWGS (RETAIL NEXT)
TC2
DC
LS
WINDOW DISPLAY
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
REFLECTED CEILING FINISH TAG
CEILING TYPE
MEP ENGINEER:
FACP
0' - 0" AFF
SYMBOL
LOUNGE DROP CLG
SINGLE FACE, RECESSED WALL MOUNTED
SINGLE FACE, WALL MOUNTED @ 9'-0" AFF
REFLECTED CEILING PLAN KEY NOTES:
1. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT UNLESS OTHERWISE NOTED.
1
LEASE LINE
19
NEW CONCEALED SPRINKLER HEAD AT GWB CEILINGS, TYP.; REF. MEP AND APPROVED SPRINKLER DWGS; FINISH WHITE.
2. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SUBMIT PLANS FOR MODIFICATION OF THE FIRE SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE THE TENANT SPACE. SUBMIT SHOP DRAWINGS TO THE LANDLORD, OWNER, AND ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL.
2
EXISTING AHU TO REMAIN; COORD. W/ MEP DWGS.
20
NEW UPRIGHT SPRINKLER HEAD AT OPEN CEILING LOCATIONS, TYP.; COORD. W/ MEP AND APPROVED SPRINKLER DWGS.
3
NEW SHELF MOUNTED WATER HEATER TO BE LOCATED ABOVE MOP SINK; B.O. SHELF AT 7'-6" AFF
21
EXISTING LANDLORD ACOUSTIC RATED CEILING ABOVE TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION; ANY DAMAGE CAUSED IN THE COURSE OF CONSTRUCTION IS TO BE PATCHED AND REPAIRED TO A 'LIKE NEW' CONDITION
3. ALL FINISHING AND PAINTING REQUIREMENTS SHALL BE AS PER THE FINISH SCHEDULE, INTERIOR ELEVATIONS, AND SPECIFICATIONS.
4
NEW LED STICK LIGHTING (TBD); INSTALL ON EACH SIDE OF MIRROR OF FITTING ROOM; FINISH HOUSING FOR LAMPING IN WHITE; PAINT EXPOSED WHIP TO MATCH ADJ. FINISH.
22
PROVIDE TRANSFER GRILLE ABOVE CEILING; REF. MEP DWGS. FOR COORD.
NEW DRAPERY PANEL INSTALLED ON TAPED-IN RECESSED CURTAIN TRACK AT FITTING ROOM OPENING; B.O. OPENING AT 7'-0" AFF; FINISH TRACK WHITE; G.C. TO COORD. INSTALLATION W/ BRAD JOBE, REF. ELEVATIONS FOR LENGTHS
23
EXHAUST FAN AND GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR
24
NEW SUPPLY GRILLE; COORD. W/ MEP DWGS; G.C. TO FINISH TO MATCH ADJ. CEILING COLOR. G.C TO PROVIDE 12" X 12" RATED ACCESS PANEL IN EXISTING CEILING OPENING ABOVE IF REQ'D AS WELL AS 24" X 24" ACCESS PANEL AT LOWER 11'-0" LOUNGE CEILING; COORD. EXACT LOCATION W/ MEP DWGS
DATE: 08/20/2018 DRAWN BY: GR, RE, NK
MINI HORIZONTAL TRACK LIGHT FIXTURE 4' SUSPENDED LINEAR LED
AMERLUX-HORNET HIGH POWER MERCURY LIGHTING
HORNET-HP-H-A14-18-LED-WT-TJ1120-SP-3000-97 LSA-4-4000-35K-HTA-U55-UNI
WHITE
18W
45
GC TO CONFIRM QUANTITY UPON RECEIPT OF DELIVERY
WHITE
34W
5
SUSPENDED FROM CEILING/DECK ABOVE @ 11'-0" AFF
4. ALL LIGHT FIXTURES, INCLUDING EXIT LIGHTS, EMERGENCY LIGHTS, ETC., SHALL BE FURNISHED BY OWNER AND INSTALLED BY THE CONTRACTOR, EXCEPT THE G.C. SHALL PROVIDE AND INSTALL THE LAMPS FOR THE SM-1 AND P-1 FIXTURES.
5
FL-1 EM
4' SUSPENDED LINEAR LED EMERGENCY
MERCURY LIGHTING
LSA-4-4000-35K-HTA-U55-UNI-EM10BSL3102W
WHITE
34W
2
SUSPENDED FROM CEILING/DECK ABOVE @ 11'-0" AFF
5. THE CONTRACTOR SHALL USE A LASER LEVELING DEVICE FOR THE LEVELING OF ALL SOFFITS, CEILINGS, AND SUSPENDED GRIDS, TYPICAL.
6
G.C TO PROVIDE PRICING TO DEMOLISH AND RE-BUILD EXIST, 2HR RATED ACOUSTIC CEILING AS REQ'D FOR NEW WORK SCOPE
25
FL-2
SURFACE MOUNTED LINEAR LED
MERCURY LIGHTING
LSA-4-4000-35K-HTA-U55-UNI
WHITE
34W
1
CEILING SURFACE MOUNTED
6. THE ELECTRICAL CONTRACTOR IS TO VERIFY THAT THE EXISTING SERVICE IS ADEQUATE FOR THE DESIGN LOADS. IF NOT, NOTIFY THE ARCHITECT AND MEP ENGINEER IMMEDIATELY.
7
HS - MERCHANDISING TRACK (ARAKAWA CRB.1800A) RECESSED IN STOREFRONT CEILING, G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE AND FASTEN TRACK TO BLOCKING EVERY 16" O.C.; LENGTHS TO BE CUT AND COORDINATED IN FIELD, REF. A-102B FOR DIMENSIONS; G.C. TO POWDER-COAT TO MATCH ADJACENT FINISH.
26
EXIT SIGNAGE; RECESSED WALL MOUNTED; COORD. W/ ELEVATIONS
27
MODCLOTH CORNER NON-ILLUMINATED BLADE SIGN
28
NEW WALL MOUNTED SPEAKERS; G.C TO PROVIDE CONDUIT AND PULL STRING; COORD. W/ VENDOR
#
ISSUE
DATE
29
LIGHT FIXTURE TBD,G.C PROVIDE 10 LED 9W LED A19 LAMPS
1
ISSUE FOR PERMIT
09/07/2018
30
NEW CURVED DOME CLG; REF. CLG DETAILS A-501 AND BUILDING SECTIONS
31
NEW DROP CLG; REF. CLG DETAILS A-501 AND BUILDING SECTIONS
FL-1
P-5
LED STICK LIGHTING
P-6
VANITY LIGHTING
R-1
R-2
R-3
R-5 R-6
TL-1 TR-1
SEMI-RECESSED LIGHT WITH 1-TRACK HEAD
SEMI-RECESSED LIGHT WITH 2-TRACK HEADS
SEMI-RECESSED LIGHT WITH 3-TRACK HEADS
3"Ø DIMMABLE LED RECESSED DOWNLIGHT 3"Ø DIMMABLE LED RECESSED ROUND DOWNLIGHT WITH TRIMLESS FLANGE LED TAPE LIGHTING SURFACE MOUNTED LIGHT TRACK
HERA TBD AMERLUX-HORNET HIGH POWER
AMERLUX-HORNET HIGH POWER
AMERLUX-HORNET HIGH POWER
STICK3/46/WW, STICK3/24/WW, STICK3/8/WW TBD HORNET-HP-R/SR-FRAME-1-LED-12 0/ HORNET-HP-R-TRIM-A14-2-18-LEDWT-120-277-MFL-WT-3000-97 HORNET-HP-R/SR-FRAME-2-LED-12 0 / HORNET -HP-SR-TRIM-A14-2-18-LED-WT-120277-MFL-MFL-WT-3000-97 HORNET-HP-R/SR-FRAME-3-LED-12 0 / HORNET -HP-SR-TRIM-A14-3-18-LED-WT-120277-MFL-MFL-MFL-WT-3000-97
WHITE
50W/MIRROR
BRASS
(3) 8 W LED LAMPS 18W
WHITE
08 16 1 15
INSTALL 2 STICK LED ON EITHER SIDE OF MIRROR; 50W PER MIRROR ABOVE RESTROOM MIRROR
9. WHITE
18W
1
SEMI-RECESSED CEILING MOUNTED
10.
ALL VENDORS TO BE COORD. BY G.C.
8
NEW EXIT SIGNAGE: RECESSED CEILING MOUNTED; COORD. W/ ELEVATIONS.
9
NEW EXIT SIGNAGE: SURFACE WALL MOUNTED; COORD. W/ ELEVATIONS.
10
SURFACE MOUNTED TRACK LIGHTING IN LIGHT COVE; FINISH WHITE; G.C. TO PROVIDE FRT PLYWOOD BLOCKING ABOVE; REF. A-501 FOR CONSTRUCTION DETAILS; COORD. W/ MEP DWGS.
KEEP ALL NEW COMPONENTS MOUNTED AS HIGH AS POSSIBLE IN EXPOSED CEILING
PROJECT NO.: 218231
CHECKED BY: JSP AREA: 1807 SQ.FT
ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT 11. CONCEALED WHERE POSSIBLE.
11
SUSPENDED CHANDELIER TBD, MOUNT B.O. CHANDELIER @ 8'-8", VERIFY IN FIELD; G.C. TO PROVIDE LED A19- 9W BULBS; 2700K
32
NEW CONCEALED CONTINUOUS 1" TAPED-IN LINEAR SLOT DIFFUSER AT WALL ABOVE DROP CEILING; COORD. W/ MEP DWGS, TYP.
12
ILLUMINATED MODCLOTH SIGNAGE; COORD. W/ MEP DWGS & SIGNAGE VENDOR; G.C. TO COORD. AND SUPERVISE INSTALL. SIGNAGE FILED UNDER SEPARATE PERMIT.
33
SUSPENDED CHANDELIER TBD, MOUNT B.O. CHANDELIER @ 8'-8", VERIFY IN FIELD; G.C. TO PROVIDE FROSTED G16 60W INCANDESCENT LAMPS; 2700K
WHITE
ACCESS PANELS IN CEILING MUST BE LOCATED TO PROVIDE ACCESS TO LANDLORD'S MECHANICAL 12. EQUIPMENT PER LOCAL GENERAL GROWTH AUTHORITY. G.C TO PROVIDE ACCESS PANELS AT ALL REQUIRED OLCATIONS
13
G.C. TO PROVIDE 12" x 12" ACCESS PANEL AT CEILING NEAR STOREFRONT WINDOW DISPLAY (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR SIGNAGE DRIVER ACCESS, COORD. EXACT LOCATION W/ MEP DWGS AND SIGNAGE VENDOR.
34
LIGHT FIXTURE TBD; CENTERED ABOVE MIRROR @ 7' - 0" AFF; REF. ELEVATIONS
13. SPRINKLER HEADS AT GYPSUM BOARD CEILING MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING TILES WHERE APPLICABLE
35
CEILING JBOX FOR FUTURE ILLUMINATED NEON SIGNAGE PROVIDED BY MODCLOTH
14
CONTINUOUS 1" TAPED-IN LINEAR SLOT DIFFUSER; COORD. W/ MEP DWGS, TYP.
36
IN-CEILING F.R. BLOCKING LOCATED FOR DECORATIVE SCREEN MOUNTING AND NEON SIGNAGE
15
EXISTING SUPPLY GRILLE; G.C. TO PAINT TO MATCH ADJ FINISH; COORD. W/ MEP DWGS, TYP.
37
LED TAPE LIGHTING IN COVE CONTINUOUS
16
NEW CEILING RECESSED SPEAKERS; G.C. TO PROVIDE CONDUIT AND PULL STRING, COORD W/ VENDOR
38
G.C. TO PROVIDE 18" x 18" ACCESS PANEL AT CEILING NEAR STOREFRONT ENTRY (ACTIVAR MODEL TMW OR APPROVED EQUIVALENT) FOR DUCT HEATER, COORD. EXACT LOCATION W/ MEP DWGS AND SIGNAGE VENDOR
17
NEW GWB CEILING @ SALES AREA, FITTING ROOMS, AND WINDOW DISPLAY LOCATIONS, TYP.
39
G.C. TO PROVIDE 12" x 12" RATED ACCESS PANEL IN EXISTING CEILING OPENING IF REQ'D; G.C. TO PATCH OPENINGS TO MATCH CURRENT CEILING FIRE AND ACOUSTIC RATING
WHITE 18W
11
SEMI-RECESSED LIGHT WITH 3-TRACK HEADS
XR3NC-D-XM20-30K-1450-WH
WHITE
17W
2
RESTROOM LIGHTING
SOLAIS LIGHTING
XR3NC-D-XM20-30K-1450-WH/TR
WHITE
17W
11
FITTING ROOM LIGHTING
CONTECH
TLT12V327K12R
WHITE
12W
1
REF. ARCHITECTURAL CEILING DETAILS FOR MOUNTING IN COVE CEILING SURFACE MOUNTED TRACK; G.C. TO CUT LENGTHS PER RCP.
LT-P
8. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTS; ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIELD FIRE INSPECTOR AT THE TIME OF THE FINAL BUILDING INSPECTION.
SEMI-RECESSED CEILING MOUNTED
SOLAIS LIGHTING
CONTECH
7. ENSURE THAT ALL EQUIPMENT INCLUDES / BARES UL LABELS.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
WHITE
120 V
7
18
AREA OPEN TO EXISTING ACOUSTIC CEILING ABOVE
REFLECTED CEILING PLAN
A-102.00 SHEET 10 OF 27
ARCHITECT OF RECORD:
HATCH & SYMBOL LEGEND HATCH / SYMBOL
DESCRIPTION 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
EXISTING PARTITION TO REMAIN
NEW PARTITION
1' - 2"
ROOM NAME
11
FR 1
STORAGE CLOSET
FR 2
FR 3
ADA RESTROOM
04
05
06
07
11
10' - 7"
1
ROOM TAG
26
WIRELESS DOOR CONTACT
DC
COORD. W/ VENDOR DWGS (ADT SECURITY) COORD. W/ VENDOR DWGS (ADT SECURITY)
WHITE BLACK
1
24
1 PAIR
31
S1
COORD. W/ VENDOR DWGS (ADT SECURITY)
PAINT TO MATCH ADJ. FINISH
S
FIRE ALARM SPEAKER/STROBE WALL MOUNTED
COORD. W/ APPROVED FIRE ALARM DWGS
WHITE
REF. APPROVED FIRE ALARM DWGS
S
FIRE ALARM SPEAKER/STROBE CEILING MOUNTED W/ STEM KIT
BLACK
REF. APPROVED FIRE ALARM DWGS
CLG
ST
GB
S1
FIRE ALARM STROBE CEILING MOUNTED
COORD. W/ APPROVED FIRE ALARM DWGS
WHITE
2
WALL MOUNTED SPEAKER REF. ELEVATIONS FOR MOUNTING HEIGHT
COORD. W/ VENDOR DWGS (PLAYNETWORK)
WHITE
4
WHITE
1' - 2" 10
COORD. W/ SIGNAGE SHOP DWGS
WHITE PER VENDOR
12
23
@ 34" AFF
CLG
FR 4
FR 5
17
WA
10
DC
26
CLG
31
TC1
5
1
2
31
COORD. W/ VENDOR DWGS (ADT SECURITY)
WHITE
1
12
KP
ALARM KEY PAD; MTD @ 48" MAX.
COORD. W/ VENDOR DWGS (ADT SECURITY)
WHITE
1
16
CP
ALARM CONTROL PANEL; FINISH WHITE
COORD. W/ VENDOR DWGS (ADT SECURITY)
PER VENDOR
1
CG
ALARM CELLGUARD
COORD. W/ VENDOR DWGS (ADT SECURITY)
PER VENDOR
1
NM
ALARM VIDEO RECORDER / MONITOR
COORD. W/ VENDOR DWGS (ADT SECURITY)
PER VENDOR
1
AV
AUDIO / VISUAL CONTROL BOX
COORD. W/ VENDOR DWGS (PLAYNETWORK)
PER VENDOR
1
V
VOLUME CONTROLS, MTD @ 48" AFF MAX.
COORD. W/ VENDOR DWGS (PLAYNETWORK)
WHITE
1
WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE, MTD. 18"AFF U.N.O.
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
DEDICATED WALL MOUNTED GROUNDED 20A DUPLEX RECEPTACLE, MTD. 18"AFF U.N.O.
COORD. W/ ELECTRICAL DWGS
WALL MOUNTED GROUNDED 20A QUAD RECEPTACLE, MTD. 18"AFF U.N.O.
COORD. W/ ELECTRICAL DWGS
CLG CLG
GB J
1' - 5"
@ 34" AFF
2' - 6"
SALES
01
11
M
D
6"
D D DDDDD D
11
T
6
@ 93" AFF @ 93" AFF @ 93" AFF @ 93" AFF @ 15" AFF
14
BACK OF HOUSE
3
@ 48" AFF
8
ST
7
16
3 7/8"
ALARM SIREN
W
J CLG
28 @ 15" AFF @ 15" AFF
OS
5
11
21
13
31
CLG
33
1
REF. SHOP DWGS
25
12
OS
W
5
9"
ADA FR
10
1
32
VESTIBULE S TS
MD CLG
33
35
WHITE
13
31
09
W
REF. MEP DWGS
STORAGE CLOSET
30
08
CLG
COORD. W/ VENDOR DWGS (BANDWAVE)
AS
S
CLG
ST
20
10
WIRELESS ACCESS POINT
WA
5"
DC
COORD. W/ MEP DWGS
16
J
CLG
34
5 3/4"
REMOTE DRIVER FOR STOREFRONT SIGNAGE
D
COORD. W/ MEP DWGS
EQ S
REF. APPROVED FIRE ALARM DWGS
COORD. W/ VENDOR DWGS (PLAYNETWORK)
OCCUPANCY SENSOR CEILING MOUNTED
OS
WHITE
S
34
REF. APPROVED FIRE ALARM DWGS
CEILING RECESSED SPEAKER
SMOKE DETECTOR
SD
WHITE
27
EQ
ST
S
COORD. W/ APPROVED FIRE ALARM DWGS
ST
30 31
EQ
F
CLG
FIRE ALARM STROBE WALL MOUNTED
S1
8
OS
5 W
J
5
5 3/4"
ST
COORD. W/ APPROVED FIRE ALARM DWGS
31
03
16
CLG
SURFACE MOUNTED SECURITY CAMERA; REF. ELEVATIONS FOR MOUNTING HEIGHT
30
FITTING ROOM LOUNGE
4 30
WIRELESS MOTION DETECTOR
MD
32
W
02
14
19
1
S
24 29
10
16
31
31 J
S
34
10
29
S
CLG
CLG
CLG
6' - 0"
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O. WHITE, U.N.O.
HUBBLE CFB4G30RCR W/ 8"Ø = BRASS FLUSH COVER PLATE CFBS1R8CVRBRS; NOTE: COVER MUST ALIGN WITH FINISH FLOOR
BRASS
REF. ELECTRICAL DWGS
DATA/FAX MODEM RECEPTACLE ON DEDICATED CIRCUIT
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
LOW VOLTAGE STUB-UP; COORD. W/ A/V VENDOR (PLAYNETWORK)
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
WHIP CONNECTION
COORD. W/ ELECTRICAL DWGS
G.C. TO PAINT EXPOSED WHIP TO MATCH ADJACENT FINISH
REF. ELECTRICAL DWGS
SWITCH
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
SWITCH / OCCUPANCY SENSOR COMBINATION
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
DIMMER SWITCH
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
MASTER OVERRIDE SWITCH
COORD. W/ ELECTRICAL DWGS
WHITE, U.N.O.
REF. ELECTRICAL DWGS
J
CONCEALED IN-WALL JUNCTION BOX
COORD. W/ ELECTRICAL DWGS
N/A
REF. ELECTRICAL DWGS
J
CONCEALED IN-CEILING JUNCTION BOX
COORD. W/ ELECTRICAL DWGS
N/A
REF. ELECTRICAL DWGS
MULTI-CHANNEL 24/7 PROGRAMMABLE TIME-CLOCK
COORD. W/ ELECTRICAL DWGS
WHITE
REF. ELECTRICAL DWGS
CLG TM
T TS GB
F
6' - 5"
PROGRAMMABLE THERMOSTAT FINISH WHITE; MTD @ 48" AFF MAX.
COORD. W/ ELECTRICAL DWGS
TEMPERATURE SENSOR; FLUSH BUTTON TYPE
COORD. W/ ELECTRICAL DWGS
WHITE WHITE
WIRELESS GLASS BREAK
COORD. W/ ELECTRICAL DWGS
WHITE
FIRE PULL TO BE RELOCATED
COORD. W/ ELECTRICAL DWGS
RED
1' - 0"
TC2
10
31
12
CLG
5 3/4"
10
GB CLG
CLG
24
DEDICATED 4-GANG FLUSH FLOOR BOX; PROVIDE (3) GROUNDED 20A DUPLEX RECEPTACLES AND (1) TELE/DATA OUTLET
M
CLG CLG
22
J
CLG GB
CLG
26
25
31
31
@ 34" AFF
10
CLG
GB
J
@ 34" AFF
CLG
J CLGCLG
REF. ELECTRICAL DWGS REF. ELECTRICAL DWGS
D
D D
REF. ELECTRICAL DWGS
WHITE, U.N.O.
OS
10
17
CLG
COORD. W/ ELECTRICAL DWGS
W
EQ EQ
REF. ELECTRICAL DWGS
FLUSH CEILING MOUNTED GROUNDED 20A DUPLEX RECEPTACLE
CLG
ST
15
EQ EQ
DEDICATED WALL MOUNTED GROUNDED 20A QUAD RECEPTACLE, MTD. 18"AFF U.N.O.
WHITE, U.N.O.
33
1' - 4"
GFI
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
1
FACP
WHITE
V
COORD. W/ VENDOR DWGS (RETAIL NEXT)
AS
SHOPPER TRACK - SECONDARY UNIT
5
AV
TC2
5
5
LOUNGE
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
NM
1
9
4' - 9"
WHITE
TM
COORD. W/ VENDOR DWGS (RETAIL NEXT)
4' - 7"
SHOPPER TRACK W/ STEM KIT
31
W
2' - 0 5/8"
TC1
10
W
CP
QUANTITY
EQ
FINISH
EQ
MANUFACTURER
2' - 0 5/8"
DESCRIPTION
9' - 6 1/2"
SYMBOL
W
CG
@ 34" AFF
16
GFI @ 48" AFF
KP
J
2' - 5 5/8"
12
CLG
1' - 8"
5 3/4"
CLG
2' - 5 5/8"
MEP ENGINEER:
2' - 5 5/8"
01
REF. ELECTRICAL DWGS REF. ELECTRICAL DWGS 5 1 EXISTING
18
16
12
24
1
16
24
16
1' - 5"
1
POWER & SIGNAL PLAN
STAMP HERE:
SCALE: 1/4" = 1'-0"
POWER & SIGNAL PLAN GENERAL NOTES:
POWER & SIGNAL PLAN KEY NOTES:
1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED ON THIS PLAN AND ELEVATIONS. COORDINATED W/ THE FIXTURE PLAN ANY DISCREPANCIES REGARDING THE LOCATION(S) SHOWN HERE AND THE FIELD VERIFIED OR EXISTING CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT PRIOR TO COMMENCING THE WORK AFFECTED.
1
LEASE LINE
2
RELOCATED ELECTRICAL PANEL; COORD. W/ MEP DWGS
3
MULTI-CHANNEL 24/7 PROGRAMMABLE TIME CLOCK; COORD. W/ MEP DWGS.
2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE ELECTRICAL CODE, NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE COMPANY, AND ALL AUTHORITIES HAVING JURISDICTION.
4
21
SHOPPER TRACK TRAFFIC COUNTER SURFACE MTD; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE
22
SHOPPER TRACK TRAFFIC COUNTER SECONDARY UNIT WHITE SURFACE MTD; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ VENDOR (RETAIL NEXT); FINISH WHITE
NEW WHIP FOR LIGHT FIXTURE(TBD); CENTER ON MIRROR @ (TBD); REF. ELEVATIONS; FINISH TBD
23
WIRELESS MOTION DETECTOR; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)
5
NEW WHIP FOR LGHT FIXTURE(TBD); CENTER ON MIRROR @ (TBD); REF. ELEVATIONS; FINISH (TBD)
24
WIRELESS GLASS BREAK; FINISH WHITE; COORD. INSTALL W/ SECURITY VENDOR (ADT)
3. U.N.O. , ALL COVERPLATES AND DEVICES ( ELECTRICAL, SWITCHES, RECEPTACLES, COVER PLATES), SHALL HAVE FINISH COLOR TO MATCH ADJACENT FINISH COLOR.
6
SWITCH BANK; FINISH FOR ALL SWITCHES TO BE WHITE; ALL SWITCHES MTD. @ 48" AFF MAX, TYP.; ALL LIGHTING OTHER THAN BOH, EXTERIOR SIGNAGE, AND VESTIBULE IS TO BE DIMMABLE
25
4. ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH (2) PULL STRINGS BACK TO THE TELEPHONE EQUIPMENT.
7
MASTER OVERRIDE SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.
WALL MOUNTED CAMERA; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL W/ SECURITY VENDOR (ADT); G.C. TO PAINT HOUSING TO MATCH ADJ. SURFACE; REF. ELEVATIONS FOR MOUNTING LOCATIONS
8
OCCUPANCY SENSOR COMBINATION SWITCH; FINISH WHITE; MTD. @ 48" AFF MAX.
9
WALL MOUNTED G.F.I. DUPLEX RECEPTACLE; FINISH WHITE; VERIFY EXACT LOCATION IN FIELD; COORD. W/ MEP DWGS.
10
WALL MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O.
5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALL CHASES IN THE FLOOR, WALLS, AND CEILING SURFACES AND MATERIALS AS REQUIRED. 6. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED SHALL BE PATCHED FLUSH WITH ADJACENT WALL SURFACES. 7. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL NOT EXCEED 6". 8. PROVIDE A MINIMUM OF 10% SPACE CIRCUITS IN EXISTING ELECTRICAL PANEL(S) PROVIDE BREAKER LOCKOUTS FOR VAV UNITS AND SEPARATE CIRCUIT OUTLINES AT TELEPHONE EQUIPMENT. 9. SEE ELECTRICAL DRAWINGS FOR FIRE ALARM LOCATION AND REQUIREMENTS. 10. ALL WIRING IN EXPOSED AREAS AND CEILINGS TO BE IN EMT CONDUIT (RIGID). KEEP CONDUIT CONCEALED WHERE POSSIBLE.
11
WALL MOUNTED DEDICATED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" AFF U.N.O.
12
CEILING MOUNTED DUPLEX RECEPTACLE; FINISH WHITE; MTD @ 18" MAX. FROM GLAZING TYP.
13
MOUNT (2) QUAD RECEPTACLES AND (1) TELE/DATA OUTLET @ 93" AFF ABOVE TELE/DATA BOARD, AND (1) QUAD RECEPTACLE @ 15" MIN. AFF BELOW TELE/DATA BOARD. REF. ELEVATIONS
14
PROVIDE (1) LOW VOLTAGE STUB UP @ 15" MIN. AFF BELOW TELE/DATA BOARD AND (1) LOW VOLTAGE STUB UP @ 93" AFF ABOVE TABLE. REF. ELEVATIONS
15
DEDICATED 4-GANG FLUSH FLOOR BOX UNDER CONSULTATION TABLE: HUBBLE CFB4G30RCR W/ 8"Ø BRASS FLUSH COVER PLATE CFBS1R8CVRBRS; G.C. INSTALL BEFORE SLAB IS POURED, REF. A-104 FINISH PLAN
DATE: 08/20/2018
27
SECURITY KEYPAD; FINISH WHITE; MTD. @ 48" AFF MAX; G.C. TO COORD. INSTALL W/ SECURITY VENDOR (ADT)
CHECKED BY: JSP
28
VOLUME CONTROL; FINISH WHITE MOUNTED @ 48" AFF MAX. ONTO TELE/DATA BOARD; REF. ELEVATIONS FOR MOUNTING LOCATION; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK)
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
29
RECESSED CEILING MOUNTED SPEAKER; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH WHITE
30
WALL MOUNTED SPEAKER WITH CONCEALED IN-WALL J-BOX, MOUNTED; G.C. TO PROVIDE CONDUIT & PULL STRING; COORD. INSTALL WITH AUDIO VENDOR (PLAYNETWORK); FINISH BLACK; G.C. TO ENSURE SPEAKERS ARE INSTALLED HORIZONTALLY AND DIRECTED DOWN TOWARD SALES FLOOR; REF. ELEVATIONS FOR MOUNTING LOCATIONS
31
RUN ALL AV/DATA AND LOW VOLTAGE VENDORS TO B.O.H.; G.C. TO PROVIDE CONDUIT AND PULL STRING FOR ALL.
32
WALL MOUNTED FIRE ALARM STROBE; FINISH WHITE; COORD. W/ MEP & APPROVED FIRE ALARM DWGS
CONCEALED MOUNTED J-BOX FOR TRACK LIGHTING AND LIGHTING ABOVE; COORD. W/ MEP DWGS
33
RELOCATED WALL MOUNTED FIRE ALARM STROBE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM
17
CONCEALED REMOTE DRIVER FOR NEW ILLUMINATED STOREFRONT SIGNAGE AND BLADE SIGN
34
18
SURFACE MOUNTED DUPLEX RECEPTACLE 5325-W ON DISPLAY PLATFORM; FINISH TO MATCH ADJ. SURFACE
CELING MOUNTED FIRE ALARM SPEAKER/STROBE; FINISH WHITE; COORD. W/ MEP DWGS & APPROVED FIRE ALARM DWGS
35
FIRE PULL AND KEYPAD; GC TO CONCEAL WIRING IN-WAL
EXISITING PRAGRAMMABLE THERMOSTAT TO REMAIN; COORD. W/ MEP DWGS.
20
FLUSH WHITE BUTTON TYPE TEMPERATURE SENSOR; COORD. W/ MEP DWGS.
PROJECT NO.: 218231
CEILING MOUNTED CAMERA; G.C. TO PROVIDE CONDUIT & PULL STRINGS; COORD. INSTALL W/SECURITY VENDOR (ADT); G.C. TO PAINT HOUSING TO MATCH ADJ SURFACE.
26
16
19
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
DRAWN BY: GR, RE, NK AREA: 1807 SQ.FT
POWER AND SIGNAL PLAN
A-103.00 SHEET 11 OF 27
HATCH & SYMBOL LEGEND DESCRIPTION
EXISTING PARTITION TO REMAIN
NEW PARTITION
2
2
NEW CONCRETE TOPPING; C-01 RAISED CONCRETE SLAB; C-02
LOUNGE
FITTING ROOM LOUNGE
FITTING ROOMS
STORAGE CLOSET
RESTROOM
02
03
04 & 06-10
05
11
PT-01
WALL
PT-01
WALL
PT-01
WALL
PT-01
WALL
T-02/PT-01
BASE
B-01
BASE
B-01
BASE
B-01
BASE
B-01
BASE
B-03
FLOOR
WF-01B
FLOOR
WF-01B
FLOOR
WF-01A
FLOOR
WF-01A
FLOOR
T-01
2 C-02 12 6
WF-01B
BASE
B-01
FLOOR
C-02
WF-01A
WF-01A
C
WF-01A
T-01
14
B-03
CPT-01
04 & 06-10 5 1
I
BASE
N/A
FLOOR
WF-01A
FINISH TAG
16
C
B-01
WALL
FLOOR
C-01
BASE
WF-01B B-01 C
C
10 WF-01A 6
B-01
C
C-02
E 2
2
N/A
EQ
MANUFACTURER
B-01
PAINTED WOOD WALL BASE
G.C.
B-02 B-03
RUBBER WALL BASE TILE COVE WALL BASE
SALES/LOUNGE/FITTING ROOMS BOH RESTROOM
C-01
CONCRETE TOPPING SLAB
REMOVABLE AREA RUG
FB-01 GL-01 MS-01
FABRIC - DRAPERY PANEL MIRROR MARBLE SADDLE
MT-01 MT-04
BRASS POWDER-COATED METAL WHITE INTERIOR PLASTER PLASTIC LAMINATE INTERIOR PAINT
FINISHES
PAINT GRADE POPLAR; PAINTED TBD
DIMENSIONS
FITTING ROOM ARCHED TRANSITION DISPLAY PLATFORMS WALL
TEXSTON
TUSCANY; COLOR: TBD
--
G.C. TO PROVIDE DRAW DOWNS FOR APPROVAL
FORMICA BEHR
COLORCORE - WHITE BIT OF SUGAR; PR-W14
---
TOP OF PLATFORM G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL; PAINT LINE AT BOH: 12'-0" AFF. G.C. TO PAINT ALL WALLS ABOVE THIS LINE PT-02. G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL G.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL TRIANGLE - ON POINT 6", 5/16" THK: GROUT: "MAPEI", COLOR: TBD; GROUT JOINT TO BE 1/8"; G.C. TO SEAL ALL GROUT PER MANUFACTURER'S RECOMMENDATIONS STRAIGHT SET - 2" X 6", 5/16" THK: GROUT: "MAPEI", COLOR: TBD; GROUT JOINT TO BE 1/8"; G.C. TO SEAL ALL GROUT PER MANUFACTURER'S RECOMMENDATIONS FINISH TO MATCH CONTROL SAMPLE FINISH TO MATCH CONTROL SAMPLE G.C. TO FOLLOW PLANS FOR PATTERN AND LAYOUT POINTS G.C. TO FOLLOW PLANS FOR PATTERN AND LAYOUT POINTS
INTERIOR PAINT
DOORS/WOOD BASE TRIM
BENJAMIN MOORE
SIMPLY WHITE OC-117; SEMI-GLOSS
--
PT-03
INTERIOR PAINT
CEILING
BENJAMIN MOORE
SIMPLY WHITE OC-117; FLAT
--
T-01
TILE FLOORING
RESTROOM
FIRECLAY TILE
TRIANGLE ON POINT - 6"; COLOR: TBD; FINISH MATTE NON-REFLECTIVE SURFACE
6"
T-02
WALL TILE
RESTROOM
FIRECLAY TILE
STRAIGHT SET - 2" X 6"; COLOR: TBD; FINISH MATTE NON-REFLECTIVE SURFACE
2" X 6"
WHITE OAK WALNUT WOOD ENGINEERED WOOD FLOOR
WF-01B
ENGINEERED WOOD FLOOR - HERRINGBONE PATTERN
A
6" H
PT-02
WD-01 WD-03 WF-01A
REMARKS/NOTES
REFER TO A-600 FOR DETAILS AND TRIM PROFILES JOHNSONITE TRADITIONAL WALL BASE; MODEL# JODC2824X; FINISH TBD 4"H REFER TO A-600 FOR DETAILS FIRECLAY TILE ARCHITECTURAL MOLDINGS 6" X 6" BASE; COLOR: TBD; FINISH MATTE 6" H ANCYRA, 6" X 6", .63" THK: GROUT: "MAPEI", NON-REFLECTIVE SURFACE COLOR: TBD; GROUT JOINT TO BE 1/8"; G.C. TO SEAL ALL GROUT PER MANUFACTURER'S RECOMMENDATIONS SALES UNCONVENTIONAL CEMETITIOUS OVERLAY; COLOR: LIGHT GRAY; FINISH: SEMI-GLOSS -GRIND, SEAL, AND POLISH W/ 16 GRIT DIAMOND FLOORING TO 1500 GRIT; G.C. TO TEST IN INCONSPICUOUS LOCATION AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT SALES/BOH G.C.'S VENDOR LIGHTWEIGHT CONCRETE; COLOR: LIGHT GRAY; FINISH: CLEAR MATTE -SEAL WITH CLEAR MATTE SEALANT G.C. TO SEALANT ENSURE SMOOTH ANS LEVEL FINISH WITHIN 1/4" OVER 10'-0"; G.C. TO TEST IN INCONSPICUOUS LOCATION AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT WINDOW DISPLAY, BOH & EXISTING EXISTING SLAB TO REMAIN -G.C. TO PREP FLOOR PER MANUFACTURERS STORAGE CLOSET RECOMMENDATIONS LOUNGE TBD TBD 116" W X 108" L NOT INSET; COORDINATE WITH FLOOR FINISH PLAN; BY OWNER (MODCLOTH) FITTING ROOMS HALF PRICE DRAPES SIGNATURE AQUA MIST BLACKOUT VELVET CURTAIN - VPCH-140803 50" W X 108" L BY OWNER (MODCLOTH) LOUNGE/FITTING ROOMS F.C. CLEAR REFLECTIVE MIRROR, TEMPERED REF. PLANS RESTROOM MARBLETHRESHOLDS.C WHITE GRAY POLISHED MARBLE THRESHOLD - DOUBLE STANDARD REF. PLANS F/I BY G.C.; REFER TO A-600 FOR DETAILS OM BEVEL TRANSITIONS/FIXTURES TBD TBD -F/I BY F.C. SIGNAGE SIGN VENDOR POWDER COAT TO MATCH PT-XX (TBD) -F/I BY SIGNAGE VENDER
FIXTURES MILLWORK LOUNGE/FITTING ROOMS/VESTIBULE LOUNGE/FITTING ROOMS
F.C. F.C. IV WOOD
NATURAL OAK WOOD, PLAIN SAWN; FINISH: CLEAR MATTE NATURAL WALNUT WOOD; FINISH: CLEAR MATTE WHITE OAK FLAT SAWN, CUSTOM BONOBOS MATTE FINISH
--3" W PLANKS
IV WOOD
WHITE OAK FLAT SAWN, CUSTOM BONOBOS MATTE FINISH
3" W PLANKS
FLOOR
WF-01A
EQ
2
2
12
12
WF-01A
WF-01A
7
F
2 12
6
10 11
10
PT-01
C-01
C-02
BASE
B-01
B-01
B-02
FLOOR
C-01
STORAGE CLOSET
WALL
PT-01
BASE
B-02
FLOOR
C-02
WALL
PT-01
BASE
B-02
FLOOR
C-02
1
PLATFORM DISPLAY AREA
8
01
C-02
WF-01A
TYP.
1
FLOOR
FLOOR
3
TYP.
WALL
B-01
B-01
WF-01A
3' - 0"
01
BASE
BASE
14
SALES
PT-01
PT-01
BACK OF HOUSE
2
WALL
WALL
13
3
6' - 8 3/8"
LOCATION
N/A
2
VIF
DESCRIPTION
CPT-01
B
9
FINISH CODE
EXISTING CONCRETE SLAB
16
WF-01A
FINISH SCHEDULE
RAISED CONCRETE SLAB
6
2
MT-01
FLOOR
BASE
12
12
C
02
BASE
PL-01
2
MT-01
PT-01A
WALL
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
VESTIBULE
2 12
WALL
WALL
FITTING ROOM TRANSITION
15
C
LOUNGE TRANSITION
ROOM #
PLM-01 PT-01
C
02
ROOM NAME
12
D
LOUNGE TRANSITION
LAYOUT STARTING POINT
12
4
FACP
NEW ENGINEERED WOOD FLOOR HERRINGBONE PATTERN WF-01B
PT-01
2
12
13
B-01
WALL
WF-01A
2
2 12
EQ
NEW ENGINEERED WOOD FLOOR WF-01A
H
WF-01A
02
PL-01
1
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
WF- 01B HERRINGBONE FLOOR PATTERN 3" WIDE PLANKS
PLATFORM DISPLAY AREA
C-EXG
2
MEP ENGINEER:
NEW TILE FLOOR T-01
C-02
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
WALL
EQ
HATCH / SYMBOL
ARCHITECT OF RECORD:
15
2
G C-02
C-02
1
1
FLOOR & WALL FINISH PLAN
STAMP HERE:
SCALE: 1/4" = 1'-0"
FLOOR AND WALL FINISH PLAN GENERAL NOTES: 1. ALL FINISHING AND PAINTING REQUIREMENTS BE AS PER FINISH SCHEDULE, ELEVATIONS AND SPECIFICATIONS. 2. ALL INTERIOR GWB PAINT TO BE SPRAY APPLIED AND BACKROLL FINISHED. SAMPLE TO BE PROVIDED TO ARCHITECT FOR APPROVAL. G.C. AND F.C. TO COORDINATE AND MATCH PAINTED FINISHES. 3. ALL CONCRETE FINISHES TO FOLLOW DESCRIPTION PROVIDED IN FINISH SCHEDULE; SAMPLE TO BE PROVIDED IN FINISH SCHEDULE; G.C. TO TEST FINISH IN BOH AND OBTAIN ARCHITECT'S APPROVAL PRIOR TO PROCEEDING THROUGHOUT. 4. INSTALLATION OF FINISHES AND FIXTURES TO BE COORDINATED BETWEEN G.C., F.C., AND ALL VENDORS, TYP. 5. G.C. TO SUBMIT SAMPLES OF ALL FINISHES FOR FINAL APPROVAL PRIOR TO ORDERING OF MATERIALS OR INSTALLATION.
FLOOR AND WALL FINISH PLAN KEY NOTES: 1
LEASE LINE
2
G.C. TO SUPPLY AND INSTALL NEW PAINTED WOOD WALL BASE, B-01; REF. A-600 FOR DETAILS
3
G.C. TO SUPPLY AND INSTALL NEW RUBBER WALL BASE, B-02; REF. A-600 FOR DETAILS
4
G.C. TO SUPPLY AND INSTALL NEW TILE COVE WALL BASE; B-03; REF. A-600 FOR DETAILS
5
G.C. TO SUPPLY AND INSTALL NEW ADA COMPLIANT MARBLE SADDLE THRESHOLD; REF. A-600 FOR DETAILS
6
G.C. TO SUPPLY AND INSTALL NEW BRASS SCHLUTER STRIP THRESHOLD; REF. A-600 FOR DETAILS
7
EXISTING THRESHOLD AT STOREFRONT ENTRY TO BE REPLACED; G.C. TO VERIFY DIMENSIONS IN FIELD AND CONFIRM THAT THRESHOLD IS ADA COMPLIANT (ADD ALT: IF THRESHOLD IS NOT COMPLIANT, REMOVE AND REPLACE WITH NEW COMPLIANT THRESHOLD)
8
6. ALL MATERIALS AND FINISHES MUST BE FIRE-RATED AND HAVE FLAME RESISTANCE COMPLYING WITH LOCAL & STATE CODES. 9
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK
G.C. TO RUN POWER TO DESK AREA PRIOR TO POURING NEW SLAB ; REF. A-103 POWER & SIGNAL PLAN
CHECKED BY: JSP
NEW REMOVABLE WALK-OFF MAT AT STOREFRONT ENTRY
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
7. ALL SURFACES AT TRANSITIONS BETWEEN DIFFERENT OR EXISTING NEW MATERIALS TO BE FLUSH AND/OR A.D.A. COMPLIANT
10
NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0"
8. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS AND INFORM ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.
11
NEW 3/8"THK POLISHED CONCRETE TOPPING AT ALL SALES AREAS; G.C. TO FLOAT SUBFLOOR AS REQ'D TO ENSURE FINISHED FLOOR ALIGNS WITH ENTRY THRESHOLD; REF. A-600
12
NEW ENGINEERED WOOD FLOOR; G.C. TO LEVEL SUBFLOOR AND FLOAT AS REQ'D TO ENSURE FINISHED FLOOR ALIGNS WITH ADJACENT FLOORS; REF. A-600; AND PROVIDE CONTINUOUS VAPOR BARRIER AT ALL WOOD FLOORING
13
NEW REMOVABLE AREA RUG BY OWNER (MODCLOTH ); NO TRIP HAZARD AT PERIMETER OF AREA RUG. CARPET TO COMPLY WITH ADA LEVEL CHANGE REQUIREMENTS (ADA 2010 SECTION 303) AND SHALL NOT EXCEED 1/4" THK. OR 1/2" THK IF EDGE IS BEVELED AT A SLOPE NOT STEEPER THAN 1:2.
14
NEW TILE FLOOR AT RESTROOM. G.C. TO PROVIDE CONTINUOUS VAPOR BARRIER UNDER FLOOR AND 4" MIN. UP ADJACENT WALLS.
15
G.C. TO USE MOISTURE-RESISTANT TYPE "X" GWB AT THE WALLS IN WET AREAS, INCLUDING THE RESTROOM AND MOP SINK, TYP.
16
LAYOUT STARTING POINT
AREA: 1807 SQ.FT
FLOOR AND WALL FINISH PLAN
A-104.00 SHEET 13 OF 30
3' - 8 1/2"
EXISTING SLAB TO REMAIN EXPOSED AND CONCEALED UNDERNEATH NEW STOREFRONT PLATFORMS
3' - 2 5/8"
-0' - 3 1/4"AFF
2 7/8" 8"
1' - 5 3/4" 9' - 1 5/8"
6' - 7 3/4" 2 7/8"
2
MEP ENGINEER:
16' - 6 5/8"
EXISTING SLAB TO REMAIN; PREP FOR NEW WOOD FLOOR INSTALL
16' - 0 1/2" 2
9' - 8"
7' - 1 5/8"
5' - 4 3/4"
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
2' - 1 3/4"
2 7/8"
4' - 6 1/4"
2' - 0"
2' - 0 5/8"
A-105.00 TYP.
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
6' - 11 3/8"
- 0' - 3/8"AFF
EXISTING SLAB
NEW RAISED SLAB SLOPED TO FLOOR DRAIN AT CENTER OF RESTROOM; PREP FOR NEW TILE FLOOR INSTALL; COORD. WITH A-100 CONSTRUCTION PLAN FOR RESTROOM EXTENT
4
3' - 8 7/8"
NEW 2 7/8"THK RAISED SLAB
ARCHITECT OF RECORD:
3' - 7 1/4" 1
2 7/8"
3/8"
3 1/8"
NEW 2 7/8"THK RAISED SLAB
- 0' - 3/8"AFF
1
- 0' - 3/8"AFF NEW RAISED SLAB TO BE LEFT AS EXPOSED FINISH FLOOR AT BACK OF HOUSE AND VESTIBULE CLOSET
21' - 3"
3
2' - 7 3/8"
NEW 2 7/8"THK RAISED SLAB
18' - 7 5/8"
NEW RAISED SLAB; PREP FOR NEW CONCRETE TOPPING
1
2' - 7 3/8"
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
3
1
NEW RAISED SLAB TO REMAIN EXPOSED AND CONCEALED UNDERNEATH NEW STOREFRONT PLATFORMS
1 WALL BASE AS SCHEDULED; REF. A-104 FLOOR FINISH PLAN
ALIGN
NEW 5/8"THK GLUE DOWN WOOD FLOOR WHERE SCHEDULED; REF. A104 FLOOR FINISH PLAN
NEW 2 7/8"THK RAISED LIGHTWIGHT CONCRETE SLAB, G.C. TO ENSURE LEVEL FINISH WITHIN 1/4" OVER 10'-0"; PREP FOR NEW CONCRETE TOPPING WHERE SCHEDULED C-02
3/4"THK PLYWOOD SUBFLOOR WOOD SLEEPERS SPACED @ 24" O.C.
3/8"
TOPPING SLAB & T.O. WOOD FLOOR -0' - 0 3/8" A.F.F.
2 7/8"
CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.
1 7/8"
3/4"
5/8"
0' - 0" A.F.F.
RAISED SLAB
STAMP HERE:
SCALE: 1/4" = 1'-0"
HATCH / SYMBOL
DESCRIPTION
EXISTING PARTITION TO REMAIN
SLAB PLAN GENERAL NOTES: 1. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLAN(S) AND EXISTING CONDITIONS. 2. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER.
X" HEIGHT DIFFERENCE
WALL BASE AS SCHEDULED; REF. A-104 FLOOR FINISH PLAN
SLAB LEVEL PLAN
HATCH & SYMBOL LEGEND
NEW 3/8"THK CONCRETE TOPPING SLAB WHERE SCHEDULED, REF. A-104 FLOOR FINISH PLAN; G.C. TO ENSURE NEW FLOOR IS LEVEL WITH EXISTING STOREFRONT THRESHOLD C-01
1 A-202.00
LOCATION OF SLAB LEVEL CHANGE
3. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL OR COLUMN U.N.O. DO NOT SCALE DRAWINGS UNDER ANY CIRCUMSTANCES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER THE SCALE ON THE CONSTRUCTION DOCUMENTS. 4. G.C. TO COORD. SLAB EDGE LOCATION WITH A-100 CONSTRUCTION PLAN. 5. THIS PROJECT IS EXEMPT FROM CONCRETE TESTING (TR2 AND TR3) PER NYCBC 1704.4 EXCEPTION 2. TOTAL CONCRETE PLACEMENT ON THIS PROJECT IS 32 CUBIC YARDS.
SLAB PLAN KEY NOTES: 1
LEASE LINE
2
G.C. TO CLEAN EXISTING SLAB AND PREP FOR NEW FLOOR FINISH U.N.O.; REF. A-101 FLOOR FINISH PLAN
3
G.C. TO POUR NEW 2 7/8"THK RAISED CONCRETE SLAB AND PREP FOR NEW FLOOR FINISH U.N.O.; COORD. SLAB EDGE LOCATION WITH A-100 CONSTRUCTION PLAN
4
G.C. TO SLOPE NEW CONCRETE SLAB AT RESTROOM TO FLOOR DRAIN; COORD. WITH A-100 CONSTRUCTION PLAN AND PLUMBING DRAWINGS
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
-0' - 3 1/4" A.F.F. EXISTING SLAB
EXISTING CONCRETE SLAB, G.C. TO PREP FOR NEW FLOOR FINISHES AS SCHEDULED C-EXG
2
SLAB EDGE - CONCRETE TOPPING / WOOD FLOOR SCALE: 6" = 1'-0"
SLAB LEVEL PLAN
A-105.00 SHEET 13 OF 27
ARCHITECT OF RECORD:
EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH
NEW CHANDELIER, TYP.
GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F. MEP ENGINEER:
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. 11' - 0" A.F.F. SALES CEILING
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
11' - 0" A.F.F. LOUNGE POP-UP
PT-01A
WC-01
4' - 10"
PT-01A
LOUNGE
02
5 1/4"
PT-01A
SALES
10' - 0" A.F.F. LOUNGE CEILING
01
6' - 11"
8' - 0"
9' - 0" A.F.F. SALES TRANSITION
CH-03
2
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
0' - 0" A.F.F. FINISHED FLOOR
F.26
SECTION A SCALE: 1/2" = 1'-0"
NEW CHANDELIER, TYP.
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. 11' - 0" A.F.F. SALES CEILING
STAMP HERE:
11' - 0" A.F.F. LOUNGE POP-UP
PT-01A
SALES
LOUNGE
01
02
WC-01
10' - 0" A.F.F. LOUNGE CEILING 9' - 0" A.F.F. SALES TRANSITION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT
0' - 0" A.F.F. FINISHED FLOOR
1
SECTION B SCALE: 1/2" = 1'-0"
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
BUILDING SECTIONS
A-300.00 SHEET 14 OF 27
ARCHITECT OF RECORD:
SUSPENDED LED LIGHT, TYP.
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.
MEP ENGINEER:
13' - 3 3/4" A.F.F. LIGHT COVE 12' - 8" A.F.F. FR LOUNGE T.O. ARCH
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
11' - 0" A.F.F. SALES CEILING
PT-01A
9' - 0" A.F.F. FITTING ROOM CEILING
7' - 6" A.F.F. T.O. OPENING
FR 5 STORAGE CLOSET
FITTING ROOM LOUNGE
05
09
03
SALES
1' - 6"
5' - 0"
8' - 0"
01
0' - 0" A.F.F. FINISHED FLOOR
A.01
2
CH-01
F.01
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
-0' - 3 1/4" A.F.F. T.O. EXG SLAB
F.03
SECTION C SCALE: 1/2" = 1'-0"
NEW CHANDELIER, TYP.
EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH
DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. STAMP HERE:
11' - 0" A.F.F. LOUNGE POP-UP
FITTING ROOM LOUNGE
03
LOUNGE
02
PT-01A
10' - 0" A.F.F. LOUNGE CEILING PT-01A
9' - 0" A.F.F. FR LOUNGE TRANSITION VESTIBULE
WC-01
VESTIBULE
STORAGE CLOSET
12
13 THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018
PT-01A
DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
1' - 6"
2' - 10"
DOOR TO RESTROOM 02
0' - 0" A.F.F. FINISHED FLOOR
BUILDING SECTIONS
-0' - 3 1/4" A.F.F. T.O. EXG SLAB F.03
1
SECTION D SCALE: 1/2" = 1'-0"
CH-03
A-301.00 SHEET 15 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
13' - 3 3/4" A.F.F. LIGHT COVE 12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN
EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH
NEW CHANDELIER, TYP.
MODCLOTH NEON SIGN
11' - 0" A.F.F. SALES CEILING
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D
PT-01A
11' - 0" A.F.F. SALES CEILING
PT-01A
EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH
F.03
F.02
9' - 0" A.F.F. SALES TRANSITION
EXISTING STOREFRONT SYSTEM AND GLAZING
4
F.18
NEW FIXTURE BY F.C., TYP.
GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D
1' - 6"
TYP.
1' - 6"
TYP.
2' - 10"
PLATFORM
2' - 4 1/4"
F.03
0' - 0" A.F.F. FINISHED FLOOR NEW FIXTURE BY F.C. COORD IN-WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS; TYPICAL DIMENSIONS SHOWN
F.18
NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B
SALES WEST
2
SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR NEW DUPLEX RECEPTACLE F.23
B-01 PT-01B
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
F.03
OPEN TO LOUNGE BEYOND
2' - 6 3/4" A.F.F. WINDOW SILL 2' - 5" A.F.F. T.O. PLATFORM
PLATFORM
2' - 4 1/4"
NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PLM-01
SALES EAST SCALE: 1/2" = 1'-0"
13' - 3 3/4" A.F.F. LIGHT COVE
EXISTING STOREFRONT SYSTEM AND GLAZING TO REMAIN
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH
EXISTING PRECAST COLUMN; G.C. TO GRIND AND POLISH
11' - 0" A.F.F. SALES CEILING
NEW CHANDELIER, TYP.
STAMP HERE:
MODCLOTH NEON SIGN 11' - 0" A.F.F. SALES CEILING
10' - 10" A.F.F. T.O. DOOR
F.25 PT-01A
9' - 0" A.F.F. SALES TRANSITION
F.03 F.02
10' - 8 3/4"
FIRE ALARM SPEAKER STROBE; FINISH WHITE; MOUNT AT 96" AFF MAX (80" MIN.)
F.01
F.01
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
EXISTING DOOR PULLS TO REMAIN
EXISTING STOREFRONT DOOR TO REMAIN
PROJECT NO.: 218231
EX-01
DATE: 08/20/2018
EXISTING FIRE ALARM PANEL
DRAWN BY: GR, RE, NK
FIRE-PULL
SALES SOUTH SCALE: 1/2" = 1'-0"
B.O. CHANDELIER
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
B-01 PT-01B
B-01 PT-01B
1
SALES NORTH SCALE: 1/2" = 1'-0"
MQ
NEW FIXTURE BY F.C. COORD IN-WALL BLOCKING & FIXTURE MOUNTED HEIGHTS W/FIXTURE SHOPS
AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
2' - 5" A.F.F. T.O. PLATFORM 2' - 4 1/4"
F.23
CHECKED BY: JSP
PLATFORM
4' - 3"
2' - 5" A.F.F. T.O. PLATFORM
PLATFORM
2' - 4 1/4"
NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B
3
7' - 0"
NEW BESTLOCKS; G.C. TO PROVIDE 6 SETS OF KEYS
NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B
GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D
F.23
INTERIOR ELEVATIONS SALES SHOP
A-302.00 SHEET 16 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D
11' - 0" A.F.F. LOUNGE POP-UP
NEW CHANDELIER, TYP. 11' - 0" A.F.F. LOUNGE POP-UP
10' - 0" A.F.F. LOUNGE CEILING PT-01A
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
10' - 0" A.F.F. LOUNGE CEILING PT-01A
9' - 0" A.F.F. SALES TRANSITION
GLASS SALES FLOOR SCREEN; G.C. TO PROVIDE CEILING AND FLOOR BLOCKING AS REQ'D
F.05
NEW GLASS FIXTURE BY F.C.
EXISTING STOREFRONT SYSTEM AND GLAZING OPEN TO SALES SHOP BEYOND
PALTFORM
2' - 4 1/4"
TYP.
1' - 6"
HOLD
NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B
2' - 10"
TEMPERATURE SENSOR
0' - 0" A.F.F. FINISHED FLOOR
4
CH-03
F.20
NEW DUPLEX RECEPTACLE
CH-03
B-01 PT-01B
LOUNGE WEST
2
SCALE: 1/2" = 1'-0"
CH-03
F.25
CH-03
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
LOUNGE SOUTH SCALE: 1/2" = 1'-0"
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. NEW CHANDELIER, TYP. NEW CHANDELIER, TYP. EXISTING PRECAST COLUMNG TO REMAIN; G.C. TO GRIND AND POLISH
NEW MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
EXISTING PRECAST COLUMN; G.C TO GRIND AND POLISH
11' - 0" A.F.F. LOUNGE POP-UP
11' - 0" A.F.F. LOUNGE POP-UP
10' - 0" A.F.F. LOUNGE CEILING
10' - 0" A.F.F. LOUNGE CEILING
9' - 0" A.F.F. FR LOUNGE TRANSITION
9' - 0" A.F.F. SALES TRANSITION WC-01
PT-01A A.03
PT-01A
PT-01A
A.03 THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
GLASS LOUNGE SCREEN NEW GLASS FIXTURE BY F.C. F.05
NEW GLASS FIXTURE BY F.C. F.05
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
OPEN TO VESTIBULE BEYOND
0' - 0" A.F.F. FINISHED FLOOR
3
SCALE: 1/2" = 1'-0"
CH-03
1
LOUNGE EAST SCALE: 1/2" = 1'-0"
DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
1' - 6"
PLATFORM
2' - 4 1/4"
2' - 10"
0' - 0" A.F.F. FINISHED FLOOR B-01 PT-01B
PROJECT NO.: 218231 DATE: 08/20/2018
NEW PLATFORM FURNISHED AND INSTALLED BY G.C. FINISH TO MATCH PT-01B
LOUNGE NORTH
STAMP HERE:
F.20
CH-03
B-01 PT-01B
INTERIOR ELEVATIONS LOUNGE SHOP
A-303.00 SHEET 17 OF 27
12' - 8" A.F.F. FR LOUNGE T.O. ARCH
12' - 8" A.F.F. FR LOUNGE T.O. ARCH DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION
PT-01A
ARCHITECT OF RECORD:
DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION
PT-01A
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
FITTING ROOM CURTAIN BEYOND INSTALLED ON RODS AND RINGS
A.02
8' - 3" A.F.F. ARCHED FR TRANS. TYP.
8' - 3" A.F.F. ARCHED FR TRANS. TYP.
PT-01
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
FITTING ROOM CURTAIN BEYOND INSTALLED ON RODS AND RINGS PT-01 FB-01
OPEN TO ADA FITTING ROOM
OPEN TO FITTING ROOM 04
PL-01
OPEN TO FITTING ROOM 05
OPEN TO FITTING ROOM 01
PT-01
B-01 PT-01B
OPEN TO FITTING ROOM 02
FB-01
0' - 0" A.F.F. FINISHED FLOOR
OPEN TO FITTING ROOM 03
B-01 PT-01B
FB-01 FB-01
FR LOUNGE WEST
3
SCALE: 1/2" = 1'-0"
12' - 8" A.F.F. FR LOUNGE T.O. ARCH
0' - 0" A.F.F. FINISHED FLOOR
FR LOUNGE EAST SCALE: 1/2" = 1'-0"
12' - 8" A.F.F. FR LOUNGE T.O. ARCH DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION
DECORATIVE PENDANT LIGHTING, TYP. INSTALLATION PT-01
OPEN TO MIRROR NICHE
1" TAPED IN LINEAR SLOT
8' - 3" A.F.F. MIRROR NICHE CEILING
PT-01
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
PT-01A
7' - 6" A.F.F. T.O. OPENING
A.01
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
A.02 PT-01
OPEN TO LOUNGE OPEN TO VESTIBULE
9' - 0" A.F.F. FITTING ROOM CEILING PT-01A
MODCLOTH WALLCOVERING
EQ
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. INWALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
A.05 A.04
A.05
EQ NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
A.06
A.05
6' - 6"
A.02
8' - 3" A.F.F. MIRROR NICHE CEILING
9' - 0" A.F.F. FITTING ROOM CEILING
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
9' - 0" A.F.F. FITTING ROOM CEILING
9' - 0" A.F.F. FR LOUNGE TRANSITION
6' - 6"
9
NEW ILLUMIANTED 3-WAY MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.; G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON ZCLIPS FOR EASE OF REMOVAL OR RELOCATION
FB-01
A.06
0' - 0" A.F.F. FINISHED FLOOR
13
FR LOUNGE SOUTH
0' - 0" A.F.F. FINISHED FLOOR
11
SCALE: 1/2" = 1'-0"
FR LOUNGE NORTH
B-01 PT-01B
8
SCALE: 1/2" = 1'-0"
9' - 0" A.F.F. FITTING ROOM CEILING
FR 1,2,3 TYP. SOUTH
5
SCALE: 1/2" = 1'-0"
9' - 0" A.F.F. FITTING ROOM CEILING
B-01 PT-01B
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
A.07
A.06
2
SCALE: 1/2" = 1'-0"
EQ
EQ A.06
A.07
A.05
HIDDEN DOOR TO STORAGE CLOSET
B-01 PT-01B
STAMP HERE:
SCALE: 1/2" = 1'-0"
9' - 0" A.F.F. FITTING ROOM CEILING
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
0' - 0" A.F.F. FINISHED FLOOR
FR 4,5 TYP. SOUTH
9' - 0" A.F.F. FITTING ROOM CEILING
PT-01A PT-01A
FB-01
FR 4,5 TYP. WEST
9' - 0" A.F.F. FITTING ROOM CEILING
PT-01A
FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS
0' - 0" A.F.F. FINISHED FLOOR
TYP.
0' - 0" A.F.F. FINISHED FLOOR
9"
9"
B-01 PT-01B
B-01 PT-01B
TYP.
A.06
PT-01A
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
NEW MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
A.04 A.05
A.05
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
A.04
06
FB-01
MODCLOTH WALLCOVERING A.06
FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS
A.06
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
B-01 PT-01B
12
FR 1,2,3 TYP. WEST SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR B-01 PT-01B
B-01 PT-01B
10
FR 1,2,3 TYP. NORTH SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR
7
FR 1,2,3 TYP. EAST SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR
B-01 PT-01B
4
FR 4,5 TYP. NORTH SCALE: 1/2" = 1'-0"
B-01 PT-01B
1
FR 4,5 TYP. EAST SCALE: 1/2" = 1'-0"
INTERIOR ELEVATIONS FR AND FR LOUNGE
A-304.00 SHEET 18 OF 27
ARCHITECT OF RECORD:
1' - 8"
A.04
ADA BENCH BY F.C. INSTALLED BY G.C.; G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D F.12
A.04 A.04
HOLD HOLD
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
F.12
6"
0' - 0" A.F.F. FINISHED FLOOR
6"
B-01 PT-01B
B-01 PT-01B
1' - 8"
HOLD 1' - 5"
TYP.
9"
0' - 0" A.F.F. FINISHED FLOOR
1' - 9"
4"
TYP. 4' - 0"
5' - 0"
TYP.
HOLD
4' - 0"
5' - 0"
TYP.
HOLD 5' - 0"
4' - 0"
A.05
6"
4" HOLD 1' - 5"
1' - 9"
1' - 2"
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
3' - 0"
B-01 PT-01B
3' - 6"
6"
F.12
ADA FR WEST
9
SCALE: 1/2" = 1'-0"
ADA FR SOUTH
6
SCALE: 1/2" = 1'-0"
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
1' - 2"
0' - 0" A.F.F. FINISHED FLOOR
1' - 8"
HOLD
HOLD
12
MEP ENGINEER:
A.06
1' - 3"
6"
6"
HOLD
A.05
2' - 2 1/4"
2' - 7 1/4"
6"
6' - 6"
A.04
1' - 0"
1' - 0"
A.04
1' - 0"
FITTING ROOM CURTAIN INSTALLED ON RODS AND RINGS
HOLD
A.04
2' - 0"
FB-01
PT-01A
TYP. 5' - 0"
2' - 2 1/4"
6"
BRASS METAL HOOKS FURNISHED AND INSTALLED BY G.C; G.C. TO PROVIDE IN-WALL FRT PLYWOOD BLOCKING AS REQ'D
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. INWALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
4' - 0"
A.06
EQ.
PT-01A
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
9' - 0" A.F.F. FITTING ROOM CEILING
TYP.
2' - 7 1/4"
EQ.
NEW ILLUMINATED MIRROR; G.C. TO F/I MIRROR; CONFIRM FIELD DIMS. AND SECURE WITH MASTIC TO FRAME BY F.C.;G.C. TO COORD. IN-WALL BLOCKING & FIXTURE MOUNTING HEIGHTS W/ FIXTURE SHOPS; TYPICAL DIMENSION SHOWN; MIRROR TO BE MOUNTED ON Z-CLIPS FOR EASE OF REMOVAL OR RELOCATION
4' - 0"
2' - 2 3/4"
5"
PT-01A
HOLD 5' - 0"
MODCLOTH WALLCOVERING
9' - 0" A.F.F. FITTING ROOM CEILING
1' - 0"
9' - 0" A.F.F. FITTING ROOM CEILING
1' - 0"
9' - 0" A.F.F. FITTING ROOM CEILING
HOLD
ADA FR NORTH
3
SCALE: 1/2" = 1'-0"
ADA FR EAST SCALE: 1/2" = 1'-0"
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. SUSPENDED LED LIGHT, TYP. 9' - 0" A.F.F. VESTIBULE
9' - 0" A.F.F. VESTIBULE
PT-01A
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
7' - 6" A.F.F. T.O. OPENING PT-01A PT-01A
8' - 5 1/2"
PT-01A
DOOR TO BOH 04
OPEN TO FR LOUNGE
48" MAX.
HIDDEN DOOR TO FITTING ROOM
06
0' - 0" A.F.F. FINISHED FLOOR
B-01 PT-01B
11
B-01 PT-01B
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
STORAGE WEST
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
8
SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR
STORAGE SOUTH
5
SCALE: 1/2" = 1'-0"
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
VESTIBULE WEST
2
SCALE: 1/2" = 1'-0"
VESTIBULE SOUTH
STAMP HERE:
SCALE: 1/2" = 1'-0"
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
SUSPENDED LED LIGHT, TYP.
SUSPENDED LED LIGHT, TYP. 9' - 0" A.F.F. VESTIBULE
9' - 0" A.F.F. VESTIBULE PT-01A
PT-01A
EXISTING PRECAST CONCRETE COLUMN; G.C. TO GRIND AND POLISH
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT
PT-01A
PT-01A
EXISTING PRECAST CONCRETE COLUMN; G.C. TO GRIND AND POLISH
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
10
STORAGE NORTH SCALE: 1/2" = 1'-0"
7
STORAGE EAST SCALE: 1/2" = 1'-0"
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
B-01 PT-01B
0' - 0" A.F.F. FINISHED FLOOR
4
VESTIBULE NORTH SCALE: 1/2" = 1'-0"
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
DOOR TO RESTROOM 02
DOOR TO CLOSET 03
B-01 PT-01B
#
B-01 PT-01B
1
VESTIBULE EAST SCALE: 1/2" = 1'-0"
INTERIOR ELEVATIONS VESTIBULE, STORAGE ROOM AND ADA FR
A-305.00 SHEET 19 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
SUSPENDED LED LIGHT, TYP.
EXISTING PRECAST CONCRETE COLUMN
SUSPENDED LED LIGHT, TYP.
EXISTING STEEL DUCTING; TYP.
EXISTING STEEL DUCTING; TYP. 12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
AHU
AHU
BR BST B12
PT-01A
9' - 0" A.F.F. T.O. PARTIAL HEIGHT WALL
1' - 4"
6"
PT-01A
SH12 SH16
1' - 4"
TDSH
1' - 4"
1' - 0"
PL.05
1' - 8"
KB
9' - 0"
PL.04
9' - 0"
ACCESS PANEL
UH
PW-01
PL.06
BOH SOUTH
4' - 0"
BOH SHELVING
CF
B-02
BOH NORTH
3
SCALE: 1/2" = 1'-0"
SCALE: 1/2" = 1'-0"
4' - 0"
TELE/DATA BOARD EQUIP. LEGEND
2
SOUND GENERATION - AMP RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
3
PLAYLIST GENERATION - AUDIO RECEIVER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
4
SUSPENDED LED LIGHT, TYP.
EXISTING STEEL DUCTING; TYP.
EXISTING STEEL DUCTING; TYP. 12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F.
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. AHU
AHU
ADT MONITOR G.C. TO COORD. & SUPERVISE VENDOR INSTALL
5
AUDIO CONTROLLERS - MOUNT AT 48" AFF MAX. G.C. TO COORD. & SUPERVISE VENDOR INSTALL
6
BANDWAVE - PEPWAVE - CELLULAR ROUTER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
7
RETAIL NEXT - ALLIED TELESIS - POE SWITCH (ONLY OCCURS AT MEDIUM TO LARGE STORES) G.C. TO COORD. & SUPERVISE VENDOR INSTALL
8
ISP INTERNET HAND-OFF G.C. TO COORD. & SUPERVISE VENDOR INSTALL
9
RETAIL NEXT - HIK VISION G.C. TO COORD. & SUPERVISE VENDOR INSTALL
1' - 4 1/2"
BST B12 B16
SH12 SH16
3
NEW TELE/DATA BOARD 3/4" FRT PLYWOOD, PAINTED TO MATCH ADJACENT FINISH 2 PT-01A
SCALE: 1/2" = 1'-0"
MIN. 4' - 0"
TYP.
1' - 6"
TYP.
1' - 6"
4' - 0"
48" MAX.
04
5
7' - 0"
16 ADT VIDEO RECORDER G.C. TO COORD. & SUPERVISE VENDOR INSTALL
DOOR TO VESTIBULE
0' - 0" A.F.F. FINISHED FLOOR
2
BOH EAST SCALE: 1/2" = 1'-0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
11
15 ADT ALARM SIREN G.C. TO COORD. & SUPERVISE VENDOR INSTALL
BOH SHELVING
12
8 7
11 ADT SWITCH G.C. TO COORD. & SUPERVISE VENDOR INSTALL
14 KB: KEYBOX - MOUNT AT 48" AFF MAX. G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.
B-02
13
6
16
12 ADT MAIN BOX G.C. TO COORD. & SUPERVISE VENDOR INSTALL
05
BOH WEST
STAMP HERE:
9
BLIND DOOR TO DISPLAY PLATFORM
DISPLAY PLATFORM
15
1
13 CISCO MERAKI FIREWALL - G.C. TO SUPERVISE VENDOR INSTALL
0' - 0" A.F.F. FINISHED FLOOR
1' - 4 1/2"
5' - 0"
PT-01A
5"
4
14
TELE/DATA BOARD W/ DESK SCALE: 1" = 1'-0"
DATE: 08/20/2018 CHECKED BY: JSP AREA: 1807 SQ.FT
B-02
1
PROJECT NO.: 218231 DRAWN BY: GR, RE, NK
5 10
MOUNT ALL LOW VOLTAGE EQUIP. ABOVE 36" AFF
BOH SHELVING
5"
EQ
10 POWER GEAR SURGE PROTECTOR G.C. TO FURNISH AND INSTALL
9' - 0" A.F.F. T.O. PARTIAL HEIGHT WALL
BOH SHELVING
5"
EQ
MOUNT KEYBOX, AUDIO CONTROLS, AND KEPAD AT 48" AFF MAX. 3' - 0"
PT-01A
TDSH: WALL MOUNTED RECEIVER SHELF G.C. TO FURNISH AND INSTALL; REF. FIXTURE SCHEDULE A-101 FOR SPEC.
3"
1
SUSPENDED LED LIGHT, TYP.
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
ELECTRICAL PANEL
0' - 0" A.F.F. FINISHED FLOOR
7' - 9"
4
TIME CLOCK
0' - 0" A.F.F. FINISHED FLOOR
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
2' - 6"
REF-2
B-02
TYP.
1' - 6"
2' - 10"
TYP.
3' - 8"
DSK
INTERIOR ELEVATIONS BOH
A-306.00 SHEET 20 OF 27
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
7' - 3 5/8" HOLD
3' - 0"
1' - 0"
1' - 0"
GB
2
1'-6" MAX.
9
GB
3
MR
4
11
TYP. ADA RESTROOM 11
9
7
8 2
5
TD
0' - 0" A.F.F. FINISHED FLOOR B-03
SCALE: 1/2" = 1'-0"
14
1' - 10 1/8"
3' - 0 1/8"
PROVIDE WHIP CONNECTION FOR LIGHT FIXTURE; MOUNT 7'-0" AFF
3' - 0"
60"Ø TURNING SPACE
3
1' - 3"
3
CLEAR TYP.
CB
13
1
4
1' - 0"
4
9' - 0" A.F.F. RESTROOM CEILING
9' - 0" A.F.F. RESTROOM CEILING
1' - 5"
TYP.
TYP.
OS
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
3
SCALE: 1/2" = 1'-0"
60" CLEAR
1' - 2"
RESTROOM SOUTH
2' - 11 1/8"
B-03
HOLD
12
TYP.
6' - 4 1/8"
15 TPH
8 1/2"
A-307.00 4
8 1/2"
1' - 6"
3
56" CLEAR
2' - 4"
PL.03
3' - 6"
TPH
1' - 4"
48" MIN.
15
4' - 3 3/4"
HOLD
5' - 0"
HOLD
5' - 0"
48" MIN.
HOLD 4' - 3 3/4"
3' - 8"
PL.02
6
0' - 0" A.F.F. FINISHED FLOOR
RESTROOM WEST
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
10
PL.01
PL.03
7"
T-02
T-02
5
MEP ENGINEER:
1' - 6"
DOOR TO VESTIBULE 02
CB
3' - 9 5/8" 1
EQ CB
1' - 11 1/2"
2' - 0"
2' - 4"
1' - 0 1/2"
G.F.I @ 48" AFF
1' - 2"
EQ
6"
9' - 0" A.F.F. RESTROOM CEILING
6 5/8"
9' - 0" A.F.F. RESTROOM CEILING
PROVIDE WHIP CONNECTION FOR LIGHT FIXTURE; MOUNT 7'-0" AFF 1' - 6"
MR
CLEAR 2' - 8 1/2"
3' - 0"
GB
3' - 7 1/4"
MR 5
TD PL.02
1' - 5 3/4"
PL.01
7"
PL.02
TPH
RESTROOM NORTH
4
2
SCALE: 1/2" = 1'-0"
40" AFF MAX V.I.F.
48" MIN.
4' - 3 3/4"
1' - 4" 1' - 6"
T-02
0' - 0" A.F.F. FINISHED FLOOR
B-03
15
MAX.
2' - 10"
3' - 7"
48" MIN.
4' - 3 3/4"
T-02
TYP.
4' - 0"
PL.01
B-03
PL.03
BOTTOM OF REFLECTIVE SURFACE
1' - 6"
TD
0' - 0" A.F.F. FINISHED FLOOR
RESTROOM EAST
1
SCALE: 1/2" = 1'-0"
HATCH & SYMBOL LEGEND SYMBOL
EXISTING PARTITION TO REMAIN NEW PARTITION FURNITURE / FIXTURE / EQUIPMENT TAG
RESTROOM ACCESSORIES TAG DSK
DESCRIPTION WALL MOUNTED DESK
EL
EMPLOYEE LOCKER
GB KB
ADA GRAB BARS KEY BOX
MR TD
RESTROOM MIRROR RECESSED PAPER TOWEL DISPENSER TOILET PAPER HOLDER
TPH
DIMENSIONS MANUFACTURER 42"L x 24"D x 34"H THE CONTAINER STORE 12"W x 18"D x ULINE 72"H 18"L, 36"L, 42"L KOHLER 11.7"H x 7.9"W x MMF INDUSTRIES 3.6"D 24"W X 36"H REJUVENATION 19"H X 13"W X 4 FAUCETSINHOME 1/4"D 2 1/2"W X 3"D X GATCO 6"H
MODEL WHITE MELAMINE DESK
RESPONSIBILITY G.C.
QUANTITY 1
NOTES / REMARKS COORD. INSTALL WITH BOH REFRIGERATOR (REF-2); REF. ELEVATIONS GRAY
H-1845GR
G.C.
1
K-14561-AF, K-14564-AF, K-14565-AF 201202889
G.C. G.C.
1 EA. 1
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS COORD. W/ TELE/DATA BOARD
E4337 FTH13078
G.C. G.C.
1 1
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS RECESSED INTO WALL
4493 (BRONZE)
G.C.
1
G.C. TO PROVIDE IN-WALL BLOCKING, COORD. W/ ELEVATIONS
PLUMPING FIXTURES TAG PL.01
DESCRIPTION RESTROOM SINK
DIMENSION 20"W X 18"D
MANUFACTURER KOHLER
MODEL K-2084
RESPONSIBILITY G.C.
PL.02 PL.03
RESTROOM SINK FAUCET RESTROOM TOILET
2.2"W X 6.5"D X 6.5"H 17 5/8"W X 28 3/4"D X 30 3/4"H
MAC FAUCET KOHLER
FA444HD-17 CIMARRON K-3609
G.C. G.C.
PL.04 PL.05
SERVICE SINK SERVICE SINK FAUCET
21"W X 21 1/2"D X 44 1/2"H 8" SPREAD
TSA-1MOP B-0674-RGH
G.C. G.C.
PL.06 PL.07
WATER COOLER FLOOR DRAIN
TURBO AIR T&S BRASS AND BRONZE WORKS, INC. QUENCH MIFAB
750 F1100-2, (POLISHES BRASS TYPE 5 INCH ONLY)
G.C. G.C.
13 1/2"W x 14 1/2"D x 40 1/2"H 6"Ø STRAINER
QUANTITY NOTES / REMARKS 1 G.C. TO PROVIDE IN-WALL BLOCKING. COORD. W/ ELEVATIONS AND MEP DWGS. 1 COORD. W/ MEP DWGS. GOLD POLISH FINISH 1 G.C.TO PROVIDE OPEN-FACE ELONGATED TOILET SEAT. COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS. 1 COORD. W/ MEP DWGS.
1 1
COORD. W/ MEP DWGS. RECESS FLOOR DRAIN INTO FLOOR, G.C. TO TRENCH AS REQUIRED
STAMP HERE:
SCALE: 1" = 1'-0"
ENLARGED RESTROOM PLAN GENERAL NOTES:
DESCRIPTION
1i
ENLARGED ADA RESTROOM PLAN ENLARGED RESTROOM PLAN KEY NOTES:
1. REFER TO FINISH SCHEDULE A-104 FOR FINISH DESCRIPTIONS AND SPECIFICATIONS.
1
LEASE LINE
2. G.C. TO VERIFY PURCHASE OF ADA REQUIRED FIXTURES.
2
G.C. TO USE WATER-RESISTANT GYP. BOARD AT ALL WET AREAS
3. G.C. & F.C. TO COORDINATE CONSTRUCTION & INSTALLATION MATERIALS, METHODS, AND SCHEDULING OF FIXTURES.
3
G.C. TO PREP ALL WALLS TO RECEIVE NEW PAINT FINISH AND ENSURE LEVEL 4 FINISH, G.C. TO PAINT ALL WALLS PT-01A
4. ALL DIMENSIONS ARE TO FINISHED WALL SURFACE. G.C. TO LAY OUT ALL WALLS IN FIELD FOR VERIFICATION AND APPROVAL PRIOR TO CONSTRUCTION. CONTACT ARCHITECT'S OFFICE WITH ANY CONFLICTS.
4
NEW WALL BASE
5
G.C. TO PREP NEW DOOR AND FRAME FOR NEW PAINT FINISH. REF. DOOR SCHEDULE
5. G.C. TO SKIM-COAT ALL EXPOSED EXISTING PARTITIONS INCLUDING BUT NOT LIMITED TO DEMISING PARTITIONS. MAINTAIN A LEVEL 4 FINISH AT ALL LOCATIONS, TYP.
6
NEW WALL MOUNTED LAVATORY BY G.C.; EXPOSED PIPES SHALL BE INSULATED TO PROTECT AGAINST CONTACT; NO SHARP OR ABRASIVE SURFACES UNDER LAVATORY; COORDINATE W/ MEP DWGS.
PROJECT NO.: 218231
6. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR ALL FIXTURES THAT CONTAIN ELECTRICAL ELEMENTS/LIGHTING. G.C. TO COORDINATE WITH SHOP DRAWINGS TO BE PROVIDED BY THE FIXTURE CONTRACTOR.
7
NEW AUTOMATIC FAUCET G.C.; COORDINATE W/ MEP DWGS.
DATE: 08/20/2018
8
NEW W.C. W/ OPEN-FACE, ELONGATED TOILET SEAT BY G.C.; COORDINATE W/ MEP DWGS.
7. U.L. LISTING: G.C. AND FIXTURE CONTRACTOR ARE RESPONSIBLE FOR U.L. LISTING OF ALL FIXTURES. SEE LIGHTING AND FIXTURE DRAWINGS FOR DETAILS.
9
NEW GRAB BARS BY G.C.; COORDINATE INSTALL WITH NEW WALL FINISH; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQUIRED
8. FINISHES TO BE FIRE RATED AS REQUIRED BY STATE/LOCAL BUILDING CODES.
10
NEW G.F.I. DUPLEX MOUNTED @ 48" AFF W/ WHITE COVER PLATE; COORDINATE W/ MEP DRAWINGS
9. FOR ALL WALL TYPES SPECIFIED, G.C. TO COORDINATE AND/OR SUPPLY PLYWOOD BLOCKING AS NECESSARY BEHIND MILLWORK. COORDINATE CONSTRUCTION DETAILS AND DIMENSIONS WITH FIXTURE PLANS AND FIXTURE SHOP DRAWINGS.
11
NEW FIXED MIRROR; SURFACE MOUNTED & CENTERED ABOVE LAVATORY BY G.C.; REFLECTIVE SURFACE (NOT FRAME) TO BE MOUNTED AT 40" AFF MAX; DASHED LINE INDICATES 6" MIN. CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D
10. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR. WALL AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.
12
NEW RECESSED PAPER TOWEL DISPENSER BY G.C.; PROVIDE CONTINUOUS FRT PLYWOOD BLOCKING AS REQ'D
11. FIRESTOPPING: MAINTAIN FIRE RATING ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED SUCH AS FLOOR, PARTITION, OR WALL IN ACCORDANCE WITH ASTME 119 TESTS.
13
NEW SWITCH / OCCUPANCY SENSOR MOUNTED W/ WHITE COVER PLATE @ 46" AFF; COORDINATE W/ MEP DRAWINGS
12. ONLY NEW, FIRST-CLASS MATERIALS, EQUIPMENT, FIXTURES (INCLUDING TRADE FIXTURES) AND FURNISHING SHALL BE USED IN THE PREMISES.
14
NEW TILE UP TO 48" MIN. AFF IN RESTROOM; REF. ELEVATIONS
15
G.C. TO PROVIDE WHITE P.TRAP INSULATED COVER TO PROTECT AGAINST CONTACT
B-03
AT RESTROOM FURNISHED BY F.C., INSTALLED BY G.C. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
ENLARGED ADA RESTROOM PLAN AND ELEVATIONS
A-307.00 SHEET 21 OF 27
ARCHITECT OF RECORD:
PARITION FRAMING SCHEDULE NOTES 5 A-500
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1. ALL LT.GA. METAL STUD WALLS AND PARTITIONS REQUIRED GYPSUM BOARD ON BOTH SIDES FOR THE FULL HEIGHT OF THE STUDS (UNLESS SPECIFICALLY DETAILED OTHERWISE). 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. MINIMUM OF 3 TIGHT TURNS AT ALL WIRES.
EXISTING CEILING; G.C. TO ENSURE MAINTENANCE OF FIRE RATING AND FIRE PROTECTION
3 5/8" LT.GA. METAL STUD FRAMING; COORDINATE W/ FRAMING SCHEDULE
HEAVY DUTY SUSPENDED MAIN BEAM @ 4'-0" O.C.
2. ALL SUSPENDED WALLS SHALL HAVE GWB THAT EXTENDS AT LEAST 4 INCHES ABOVE THE SUSPENDED CEILING (UNLESS SPECIFICALLY DETAILED OTHERWISE). 3. ALL STUD WALLS AND PARTITIONS SHALL HAVE CONTINUOUS LINES OF BRIDGING SPACED AT 4'-0" ON-CENTER. THE BRIDGING SHALL BE SECURELY FASTENED TO THE STUDS WITH EITHER WELDS OR SCREWS.
MEP ENGINEER:
4. ALL STUDS SHALL BE 'C'-TYPE WITH FLANGE STIFFENERS. HEAVY DUTY SUSPENDED CROSS TEE @ 2'-0" O.C.
3 5/8" 18 GA. METAL STUD BRACING @ 8'-0" O.C. EACH DIRECTION; LENGTH OF BRACING MAY NOT EXCEED 16'-0"
1 1/2" X 3" 16 GA. CHANNEL CUP ANGLE, FASTEN TO STUD & CHANNEL W/ (4) 5/8" #5-12 SCREWS. ALT FASTENING: (3) 3/4" WELDS (AT 3 DIFFERENT PLACES)
SUSPENDED CEILING FRAMING LAYOUT - GENERAL NOTES
X R MA TE 8" IME R PE AT
8 A-500
FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS.
5/8" THK. TYPE 'X' GWB W/ FINISH AS PER FINISH SCHEDULE
2" MIN WALL MOLDING GRID MEMBERS ATTACHED TO WALL MOLDING @ 2 ADJACENT WALLS USING POP RIVETS OR SCREWS
3/4" 18 GA. COLD ROLLED CHANNEL BRACING SPACED @ 4'-0" O.C. HORIZONTALLY, TYPICAL
5/8" GYP. BD. NOTE: CEILING IN SEISMIC DESIGN CATEGORIES D, E AND F TO COMPLY WITH ASCE 7-05
BOTTOM TRACK W/ 'HILTI' PNEUMATIC SHOT PINS, .145"Ø W/ DISCS @ 16" O.C., TYPICAL EXISTING FLOOR SLAB
A STEEL STUDS TO STEEL STUDS OR TRACKS: #8-18 X 1/2" TEKS/2 WITH PHIL. PAN-HEAD FOR 25 GA. OR 20 GA. #10-16 X 9/16" TECKS'3 WITH PHIL PAN-HEAD FOR INTERCONNECTION OF 18 GA. OR 16 GA. B. STEEL STUDS OR TRACKS TO WOOD PURLINS, GIRDERS, AND BEAMS: #14-10 X 1/2" H.W.H. TYPE 'S' METAL-TO-WOOD TEKS C. STEEL STUDS OR TRACKS TO STRUCTURAL STEEL (WIDE FLANGE BEAMS, COLUMNS, GURDERS, STEEL TUBE SHAPES, ETC): TEKS/3 OR TEKS/4 GAUGE AND LENGTH AS REQUIRED FOR THE COMBINED THICKNESS OF THE MATERIAL TO BE DRILLED D. PLYWOOD TO STEEL STUDS: #10-24 X 3/4" TEKS/3 (PLYMETAL TEKS) WITH THIN WAFER HEAD.
TYPICAL CEILING FRAMING LAYOUT DIAGRAM; N.T.S.
HEIGHT
ATTACHMENT TO STRUCTURAL SUPPORT TO COMPLY W/ LOCAL CODE 1/2" THIN WALL ELEC. CONDUIT OR APPROVED EQ. (EXTEND TUBE TO BE TIGHT TO CLG. GRID & STRUCTURE ABOVE. THEN INSTALL BOLT TO SECURE ON TO THE OTHER.)
COMPRESSION STRUT 12'-0" MAX. SPACING
DRILL 3/32" HOLE AND INSTALL 1/8" BOLT AND LOCKING NUT
FOUR 12 GA. SPLAY WIRES AT 45 DEGREES PARALLEL TO CROSS TEES
3/4" THIN WALL ELECT. CONDUIT W.SLOT AT END TO FIT OVER CLG. RUNNER. STRUTS TO BE 12'-0" ON CENTERS EACH DIRECTION 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES.
LOCKING CROSS TEES AT 4'-0" O.C. TYP
45
2"
CROSSPIECE, 2'-0" O.C.
TYP. HANGER WIRES AT 4'-0" O.C.
COMPRESSION STRUT DETAIL DIAGRAM; N.T.S.
4
8" MAX
COMPRESSION STRUT DETAIL DIAGRAM; N.T.S.
5
3 5/8" X 18 GA DL
16'-0" - 20'-0"
6" X 18 GA
6" X 18 GA
6" X 18 GA
6" X 18 GA
20'-0" - 24'-0"
6" X 18 GA
6" X 18 GA
6" X 18 GA
6" X 18 GA DL
BRACE AT STRUCTURE DIAGRAM; N.T.S.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP 2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING
(4) 2" TEK SCREWS AT EACH BOTTOM FLANGE
AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
STEEL STUD TRACK
2" 5_ " GWB CEILING 8
6" MIN.
5/8" GWB CEILING
METAL FURRING CHANNEL CLIP
UN-ATTACHED GYPBOARD CEILING
NOTE: 1. THE WIDTH OF THE PERIMETER SUPPORTING ANGLE SHALL BE 2" MIN. 2. THE CLEARANCE FROM THE GRID TO THE WALL AT THE FREE END SHALL BE 3/4" MIN. 3. THE ENDS OF THE MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT THEIR SPREADING
TYPICAL GYP. BD. CEILING WALL CONNECTION DIAGRAM; N.T.S.
3 5/8" X 18 GA
METAL STUD BRACING TO TOP CHORD OF STRUCT. @ 8'-0" O.C. MAX STAGGERED
MAX. SPACING
3/4"
6
3 5/8" X 18 GA
4" X 4" STUD WIDTH X 20 GA. CLIP ANGLES - FASTEN TO EACH BRACE AND RUNNER W/ TEK SCREWS (3 PER LEG TYP.)
24" O.C.
ATTACHED GYPBOARD CEILING
3 5/8" X 18 GA
STAMP HERE:
8" MAX
SUPPORTING ANGLE
5_ " GWB CEILING 8
UP TO 16'-0"
NOTE: MECHANICAL AND LIGHT FIXTURES MUST BE CONNECTED TO ONE (1) VERTICAL 12 GA. WIRE ATTACHED TO OPPOSING CORNERS ALONG THE FIXTURES DIAGONAL. THESE WIRES MAY BE SLACK (UBC STD. NO. 25.213, 25.214)
CEILING HANGER: 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EACH WAY AND MAX 8" FROM ALL EDGES
16 GA. CRC MAIN BEAM @ 4'-0" O.C
2"
NOT APPLICABLE
1 1\2" CHANNEL 4'-0" O.C.MAX.
CEILING HANGER: 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EACH WAY AND MAX 8" FROM ALL EDGES
16 GA. CRC MAIN BEAM @ 4'-0" O.C
2 1/2" X 18 GA
TYP. STUD WALL BRACING
THE ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT SPREADING
CEILING HANGER: 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EACH WAY AND MAX 8" FROM ALL EDGES
2 1/2" X 18 GA
MAIN BEAMS 4'-0" O.C.
MAIN TEES AT 4'-0" O.C.
THE ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT SPREADING
2 1/2" X 18 GA
4" X 4" X 20 GA. CLIP ANGLE, AT EA. BRACE PROVIDE RAMSET PIN FASTENERS (1" IMBED)
2"
MA X
11'-0" SPAN
AS NOTED
EXISTING STRUCTURE
5/8" TYPE 'X' GYPSUM BOARD MA X
8'-0" SPAN
45
45
INSTALL COMPRESSION STRUT AS REQ'D BY CODE 12 QA. VERT WIRE HANGER IN TUBING, LEVEL CEILING PRIOR TO SETTING STRUT
TOP TRACK
BOTTOM TRACK
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
2
TYPICAL 12 GA. HANGER WIRE SET IN CONCRETE SLAB ABOVE COMPRESSION STRUT PER S.F. GENERAL APPROVAL 301 R 28-2
SUPPORTING ANGLE
TYPICAL FASTENERS:
45. 0°
DETAIL AT METAL FRAMING BRACING FOR WALL PARTITIONS DIAGRAM; N.T.S.
ANGLE CLIP- PINNED AND BOLTED TO VERTICAL COMPRESSION BRACE
3
6. GC TO COORDINATE ANY AND ALL REQUIRED SPECIAL INSPECTIONS OF CEILING AND PARTITION FRAMING WITH LOCAL BUILDING CODE OFFICIAL
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
E. GYPSUM BOARD TO STEEL STUDS: #7 X 1/4" TYPE 'S' BUGLE HEAD SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 25 GA. OR 20 GA. METAL STUDS. #6 X 1/4" TYPE 'S-12' BUGLE HEAD SCREWS FOR 3/8" TO 5/8" GYPSUM BOARD TO 18 GA. OR 16 GA. METAL STUDS OR TRACKS.
4" MIN.
1
C L
MAX WEIGHT = 40 LBS PER HANG POINT
45
3/4" X 16 GA. COLD-ROLLED CHANNEL; SPACING @ 4'-0" O.C. IN HORIZONTAL DIRECTION
4'-0" O.C. HORIZONTALLY, TYP.
3 5/8" 18 GA. METAL STUD FRAMING MEMBERS @ 16" O.C.
5. THE MATERIALS AND DETAILS SHOWN ARE FOR TYPICAL INSTALLATIONS. WHERE THE STUD MANUFACTURER RECOMMENDS OR LOCAL ORDINANCES AND/OR CODES ARE MORE RESTRICTIVE OR HIGHER STANDARDS, THESE SHALL PREVAIL AND APPLY.
CEILING AS SCHEDULED SEE SCHEDULED PARTITION TYPE
7
TYPICAL SUSPENDED GYP. BD. CEILING DIAGRAM; N.T.S.
8
WALL BRACING CONNECTION DIAGRAM; N.T.S.
CEILING CONSTRUCTION DETAILS
A-500.00 SHEET 22 OF 27
ARCHITECT OF RECORD:
2' - 8 1/2" WRAP COLOR CORE LAMINATE AT CORNER
EXISTING STOREFRONT AND GLAZING TO REMAIN.
2' - 3 1/2"
3" 1 1/2"
3/4" THK PAINT GRADE MDF W/ COLOR CORE LAMINATE (WHITE)
1/2"
2' - 5" A.F.F. T.O. PLATFORM
3/4"
PAINTED WOOD BASE SCRIBE BASE TO FLOOR B-01 PT-01B
LIGHT SHIELD CONTINUOUS ALONG SLOT EXCEPT AT PLENUM BOX LOCATIONS
6" METAL STUD, SPACED AT 16" O.C. TYP
R-19 BATTING INSULATION
5/8" TYPE 'X' GYP. BOARD
3/4" THK PAINT GRADE MDF 2' - 5"
RUBBER STANDOFF; FINISH TO MATCH ADJ WALL
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
2' - 3 3/4"
1/2"
MEP ENGINEER:
BLOCKING AS REQ'D PAINTED BLACK
BRASS TRANSITION BY G.C. 7 1/4"
PLENUM BOX BEYOND; REF. MEP DRAWINGS
SLOTTED GRILL BY G.C.
WOOD BLOCKING AS REQ'D
ATTACHMENT CLIPS AS REQUIRED
3 5/8" METAL FRAMED PLATFORM BY G.C.
NEW RADIATOR TO; REF. PLANS AND MEP DWGS. FOR SPEC INFO AND LOCATIONS
COUNTERSUNK SCREW FINISH TO MATCH ADJ.
5/8" GYP. BOARD AT CEILING PT-01C
1/2" CONT. REVEAL ALONG BASE
REF. RCP 1/2"
1/2"
1/4"
0' - 0" A.F.F. FINISHED FLOOR
3 1/4"
1/4"
DUCT BEYOND; REF. MEP DRAWINGS
1/2" CONT. REVEAL ON TOP PANEL
ALIGN
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
6"
1"
HOLD
SLOT
B.O. CEILING TAPE AND SANDED PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED 1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS
HEAD & JAMP TRANSITION DETAIL
9
SCALE: 3" = 1'-0"
STOREFRONT DISPLAY PLATFORM
3
SCALE: 1 1/2" = 1'-0"
TAPED-IN LINEAR SLOT DETAIL SCALE: 3" = 1'-0"
EXISTING SLAB ABOVE TO REMAIN
EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTEN TO DEEP FLUTE OF EXISTING STRUCTURE ONLY AND COMPLY WITH LANDLORD AND BUILDING ANCHORING REQUIREMENTS, TYP.
EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTEN TO DEEP FLUTE OF EXISTING STRUCTURE ONLY AND COMPLY WITH LANDLORD AND BUILDING ANCHORING REQUIREMENTS, TYP.
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.
SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX.
EXISTING SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
1/4"Ø GALVANIZED LEVELING ROD, CONNECTED TO SPRING HANGER PER MANUFACTURER'S SPECIFICATIONS AT MAX. SPACING OF 4'-6" O.C.
1/4"Ø GALVANIZED LEVELING ROD, CONNECTED TO SPRING HANGER PER MANUFACTURER'S SPECIFICATIONS AT MAX. SPACING OF 4'-6" O.C.
NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PENETRATION, TYP.
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.
G.C. TO PROVIDE 3/4"THK CONTINUOUS FRT PLYWOOD BLOCKING ABOVE LIGHT COVE ANCHOR BOLT
ANCHOR BOLT
SURFACE MOUNTED LIGHT TRACK, REF. A-102 REFLECTED CEILING PLAN
NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIR-TIGHT AT TOP OF PARTITION
1/2"THK KINETICS WALLMAT RESILIENT PARTITION ISOLATION STRIP
3/8"THK KINETICS SRP PERIMETER ISOLATION BOARD
1/2"THK KINETICS WALLMAT RESILIENT PARTITION ISOLATION STRIP KINETICS KAI-S ANCHOR ISOLATOR BRUSHING ASSEMBLY W/ FENDOR WASHER, NEOPRENE ISOLATOR, AND CARBON STEEL SPACER
EXISTING CEILING V.I.F.
(2) LAYERS 5/8"THK TYPE 'X' GYP. BOARD AT LIGHT COVE; FINISH TO MATCH PT-01C
KINETICS KAI-S ANCHOR ISOLATOR BRUSHING ASSEMBLY W/ FENDOR WASHER, NEOPRENE ISOLATOR, AND CARBON STEEL SPACER
13' - 3 3/4" A.F.F. LIGHT COVE
5"
FIBERGLASS BATT, SPONGER NEOPRENE OR RUBBER SLEEVE AT PENETRATION, TYP.
13' - 1 1/4" A.F.F. B.O. OVERHANG
HOLD
MAINTAIN ACOUSTIC RATING AT LANDLORD'S EXISTING CEILING, TYP.
12' - 10 3/4" A.F.F.
SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX.
ALIGN
MAINTAIN ACOUSTIC RATING AT LANDLORD'S EXISTING CEILING, TYP.
7/8" FURRING CHANNELS AT RIGHT ANGLE TO COLD-ROLLED CHANNELS SPACED AT 2'-0" O.C. MAX.
VARIES
NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PENETRATION, TYP.
6"
6"
4"
5"
3"
HOLD
HOLD
HOLD
HOLD
HOLD
12' - 8" A.F.F. FR LOUNGE T.O. ARCH EXISTING STOREFRONT SYSTEM TO REMAIN; G.C. TO PROTECT THROUGHOUT CONSTRUCTION NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PERIMETER, TYP.
ATTACHMENT CLIPS AS REQUIRED VARIES
TAPE AND SANDED PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED
SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX.
1' - 10 3/4"
EQ.
3"
PLENUM BOX BEYOND; REF. MEP DRAWINGS
EQ.
1' - 0"
3"
EQ.
6"
3 3/4"
EQ.
6"
LED TAPE LIGHTING WITH ANGLE CHANNEL, CLIP. MOUNTED ON GYP. B.D (TL-1)
LOUNGE
8"
1 1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS AT SPACED 4'-0" O.C. MAX. 7/8" FURRING CHANNELS AT RIGHT ANGLE TO COLD-ROLLED CHANNELS SPACED AT 2'-0" O.C. MAX.
G.C. TO PROVIDE 3/4"THK IN-CEILING CONTINUOUS FRT PLYWOOD BLOCKING ABOVE WINDOW DISPLAY CEILING
3. NO RIGID CONNECTION BETWEEN ISOLATED CEILING, COLUMNS, DUCTWORK, WALLS OR PERIMETER FASCIA AT STOREFRONT, USE KINETICS SRP PERIMETER ISOLATION BOARD AND SEAL WITH NONHARDENING, RESILIENT ACOUSTIC CAULKING, TYP.
1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS
(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT SALES CEILING; FINISH TO MATCH PT-01C
7
STOREFRONT LIGHT COVE DETAIL SCALE: 3" = 1'-0"
1"
6"
HOLD
HOLD
TAPE AND SANDED PLASTER SKIMCOAT TO FINISH SLOT OPENING (ALL EDGES); ALL SLOT EDGES TO BE NEAT & STRAIGHT. NO IRREGULAR EDGES OR PAINT LINES WILL BE ACCEPTED
11' - 0" A.F.F. SALES CEILING VARIES REF. RCP
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018 DRAWN BY: GR, RE, NK CHECKED BY: JSP AREA: 1807 SQ.FT #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
2. G.C. TO CONFIRM BATT INSTALLATION INSTALLED ABOVE LANDLORD'S (2) LAYER GYP. BOARD CEILING
ATTACHMENT CLIPS AS REQUIRED
DUCT BEYOND; REF. MEP DRAWINGS
SCALE: 1 1/2" = 1'-0"
1. NO RIGID CONNECTION TO LANDLORD'S SLAB OR ACOUSTIC CEILING. ANY PENETRATIONS MADE TO LANDLORD'S ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATION AND SEALED WITH FLEXIBLE CAULKING TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS IS REQUIRED IN ADDITION TO THE EXISTING ACCESS PANELS LOCATED WITHIN THE SPACE, G.C. IS TO OPEN AS REQUIRED AND THEN PATCH BACK WITH (2) LAYERS OF 5/8"THK TYPE 'X' GYP. BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING
(2) LAYERS 5/8"THK TYPE 'X' GYP. BOARD AT WINDOW DISPLAY CEILING FINISH TO MATCH PT-01C
BLOCKING AS REQ'D
(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD; FINISH TO MATCH PT-03
LOUNGE CEILING DROP DETAIL
NOTES:
ARAKAWA MERCHANDISING TRACKS MODEL CRB 1800A, RECESSED INTO GWB CEILING, POWDER-COATED TO MATCH ADJ. FINISH PT-01C
LIGHT SHIELD CONTINUOUS ALONG SLOT EXCEPT AT PLENUM BOX LOCATIONS
BLOCKING AS REQ'D
1 5/8"
HOLD
PLENUM BOX BEYOND; REF. MEP DRAWINGS
10' - 0" A.F.F.
10
8"
(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT DISPLAY WINDOW SOFFIT WALL; FINISH TO MATCH PT-01A
1" TAPED IN LINEAR SLOT DIFFUSER; REF. MEP DRAWINGS
LOUNGE POP-UP
STAMP HERE:
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. & WINDOW DISPLAY CEILING
1 1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS AT SPACED 4'-0" O.C. MAX.
10' - 10" A.F.F.
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
12
CONSTRUCTION AND CEILING DETAILS
5"
A-501.00 SHEET 23 OF 27
ARCHITECT OF RECORD:
METAL STUD BRACING TO STRUCTURE AT 8'-0" OC MAX STAGGERED EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTENING TO DEEP FLUTE OF EXG STRUCTURE ONLY AND TO COMPLY WITH LANDLORD AND LOCAL BUILDING REQUIREMENTS. TYP.
ANCHOR BOLT. MODEL WALLMAT (BY KNC)
5/8" TYPE 'X' GYP BOARD
4" X 4" STUD WIDTH X 20 GA CLIP ANGLES; FASTEN TO EACH BRACE AND RUNNER WITH TEK SCREWS (3 PER LEG, TYP)
MEP ENGINEER:
4 X 2" TEK SCREWS AT EACH BOTTOM FLANGE
MODEL WALLMAT (BY KNC)
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
MODEL KAI-S ANCHOR ISOLATOR BUSHING ASSEMBLY (BY KNC) INCLUDES: FENDER WASHER NEOPRENE ELEMENT CARBON STEEL SPACER
METAL STUD BRACING SECURE TO ANGLE CLIP.
STEEL STUD TRACK 6" MIN
MODEL KAI-S ANCHOR ISOLATOR BUSHING ASSEMBLY (BY KNC) INCLUDES: FENDER WASHER NEOPRENE ELEMENT CARBON STEEL SPACER
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
ANGLE CLIP. TYP.
METAL CHANNEL; SEE A-101.00 FOR SPEC.
SUSPENDED CEILING PROVIDE EDGE BEAD; TAPE AND SPACKLE
METAL STUD; SEE A-101.00 FOR SPEC.
12
TYPICAL PARTITION AT CORNER
5/8"THK GYP BOARD
9
SCALE: 3" = 1'-0"
TYPICAL SOUND ISOLATION CONNECTION
6
SCALE: 3" = 1'-0"
TYPICAL SOUND ISOLATION BRACING CONNECTION
3
SCALE: 3" = 1'-0"
TYPICAL BRACING CONNECTION SCALE: 3" = 1'-0"
ANCHOR BOLT. MODEL WALLMAT (BY KNC)
ACOUSTICAL CAULKING. MODEL KAI-S ANCHOR ISOLATOR BUSHING ASSEMBLY (BY KNC) INCLUDES: FENDER WASHER NEOPRENE ELEMENT CARBON STEEL SPACER METAL CHANNEL; SEE A-101.00 FOR SPEC.
EXISTING SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTEN TO DEEP FLUTE OF EXISTING STRUCTURE ONLY AND COMPLY WITH LANDLORD AND BUILDING ANCHORING REQUIREMENTS, TYP.
EXISTING SLAB ABOVE TO REMAIN
14' - 10 3/4" A.F.F. B.O. CONCRETE SLAB V.I.F.
1/4"Ø GALVANIZED LEVELING ROD, CONNECTED TO SPRING HANGER PER MANUFACTURER'S SPECIFICATIONS AT MAX. SPACING OF 4'-6" O.C.
ANCHOR BOLT KINETICS KAI-S ANCHOR ISOLATOR BRUSHING ASSEMBLY W/ FENDOR WASHER, NEOPRENE ISOLATOR, AND CARBON STEEL SPACER
METAL STUD; SEE SEE A-101.00 FOR SPEC.
1/2"THK KINETICS WALLMAT RESILIENT PARTITION ISOLATION STRIP
2 3/4"
DIM PER WALL TYPE 5/8" TYPE 'X' GYP BOARD METAL CHANNEL; SEE A-101.00 FOR SPEC.
MAINTAIN ACOUSTIC RATING AT LANDLORD'S EXISTING CEILING, TYP. FIBERGLASS BATT, SPONGER NEOPRENE OR RUBBER SLEEVE AT PENETRATION, TYP.
FLOOR
3 5/8" METAL STUD FRAMING EXTEND TO EXISTING CEILING ABOVE
TYPICAL PARTITION
STAMP HERE:
SCALE: 3" = 1'-0"
ROY WILLIAMS VIBRATION PRODUCTS A KETCHUM & WALTON CO. 560 SYLVAN AVE. ENGLEWOOD CLIFFS, NJ 07632 P: 201-569-7400 F: 201-569-7417 CELL: 330-352-1273
R
15'-1" A.F.F. V.I.F. EXISTING CONCRETE SLAB
EXPANSION SHIELD ANCHOR HILTI KWIK BOLT 3 OR EQUAL; FASTENING TO DEEP FLUTE OF EXG STRUCTURE ONLY AND TO COMPLY WITH LANDLORD AND LOCAL BUILDING REQUIREMENTS. TYP. 1_ " GALVANIZED LEVELING RODS 4 ASSEMBLY TO SPRING HANGER. PER MANUFACTURER SPEC. FASTENING AT MAXIMUM OF 4'-6" O.C.
13'-1" A.F.F. V.I.F. EXISTING LL'S FIN. CEILING
MAINTAIN EXISTING LL'S ACOUSTICAL CEILING RATING.
KINETIC MODEL SRP 3_8" THICK PERIMETER ISOLATION.
NON-HARDENING, RESILIENT CAULKING SEALED AIR TIGHT AT PERIMETER. TYP.
RESILIENT ACOUSTICAL CAULKING.
SOUND ISOLATED DECK SUSPENDED CEILING HANGER. 4' X 4' O.C. MAXIMUM.
KINETICS R
KINETICS R
7_ " FURRING CHANNELS 8
AT RIGHT ANGLE TO COLD ROLLED CHANNEL AND SPACED AT 2'-0" O.C. 1-1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS WEIGHING 0.457 POUNDS PER LINEAR FOOT AT 4'-0" O.C.
11'-6" A.F.F. FINISHED CEILING
8" MAX TO FIRST SUPPORT AT PERIMETER
KINETIC MODEL SRP 3_8" THICK PERIMETER ISOLATION.
5/8" PAINTED GYP BOARD
RESILIENT ACOUSTICAL CAULKING.
FACE OF WALL NOTE: NO RIGID CONNECTION BETWEEN ISOLATED CEILING AND COLUMNS, DUCTWORK, WALLS OR PERIMETER FASCIA. USE KINETICS SRP AND FINISH WITH FLEXIBLE/NON-HARDENING SEALANT. NOTE: GC TO CONFIRM BATT INSULATION INSTALLED ABOVE LANDLORD'S TWO LAYER GYPSUM BOARD CEILING IN FIELD.
NOTE: FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND/OR LOCAL BUILDING DEPARTMENT REQUIREMENTS. SOUND ISOLATIOR, & VIBRATION ELIMINATOR ARE REQUIRED FOR ALL CEILING HUNG EQUIPMENT. NOTE: REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS
TYPICAL DRYWALL CEILING SCALE: 1 1/2" = 1'-0"
SOUND ISOLATED DECK SUSPENDED CEILING HANGER 4' x 4' O.C. MAX. 6"
NO CONTACT AT COLD ROLLED CHANNEL
1 1/2" GALVANIZED COLD-ROLLED STEEL CARRYING CHANNELS AT SPACED 4'-0" O.C. MAX. 7/8" FURRING CHANNELS AT RIGHT ANGLE TO COLD-ROLLED CHANNELS SPACED AT 2'-0" O.C. MAX. (1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT FR CEILING; FINISH TO MATCH PT-01C
PROJECT NO.: 218231 DATE: 08/20/2018
SUSPENDED DECORATIVE LIGHTS
(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT FLAT PORTIONS OF FITTING ROOM LOUNGE WALLS; FINISH TO MATCH PT-03
3 5/8" METAL STUD FRAMING SPACED AT 16" O.C. NOTE: RESILIENT ACOUSTICAL CAULKING IS REQUIRED AT ALL PERIMETERS WHERE WALL AND CEILING MEETS .
ENLARGED SECTION AT FITTING ROOM LOUNGE CEILING
DRAWN BY: GR, RE, NK 9' - 0" A.F.F. 9' - 0" A.F.F. FITTINGFR ROOM LOUNGE CEILING TRANSITION
G.C. TO TAPE AND PLASTER TO CONCEAL SEAM BETWEEN WALLS AND ARCHED CEILING, TYP.
2 1/2" METAL STUD FRAMING SPACED AT 16" O.C.
SCALE: 1 1/2" = 1'-0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
1/8"THK HAND TROWELED PLASTER FINISH OVER 2 LAYERS 1/4"THK GYP.. BOARD AT FITTING ROOM LOUNGE ARCH; G.C. TO ENSURE LEVEL 4 SMOOTH FINISH TO MATCH WALLS AND PAINT PT-03
(1) LAYER 5/8"THK TYPE 'X' GYP. BOARD AT FR WALLS; EXTEND TO 6" ABOVE CEILING LEVEL; FINISH TO MATCH PT-01A
7
0"
7/8"THK FURRING CHANNELS SPACED AT 16" O.C. TO FORM CEILING ARCH
KINETICS R
FIBER GLASS BATT, SPONGE NEOPRENE OR RUBBER SLEEVE AT PERIMETER. TYP.
4' -
6"
KINETICS
R
3 5/8" METAL STUD FRAMING SECURED AT EITHER END OF THE ROOM AND BRACED BACK TO SIDE WALL FRAMING AS REQ'D, TYP.
4"
EXISTING LL'S ACOUSTICAL SUSPENDED HANGER. TYP.
11' - 0" A.F.F. LOUNGE POP-UP
3' - 8"
ACOUSTICAL CEILING SYSTEM VENDOR'S CONTACT: GC TO COORDINATE FOR REQUIREMENTS, SPECIFICATION FOR PRICING.
NOTE: NO HARD CONNECTION TO LL’S SLAB OR ACOUSTIC CEILING. ANY PENETRATIONS MADE TO LL’S ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATIONS AND SEAL WITH FLEXIBLE CAULKS TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS REQUIRED IN ADDITION TO THE ACCESS PANEL ALLOCATED IN SPACE, GC IS TO MAKE THE CONNECTION AND THEN PATCH BACK IN WITH TWO LAYERS OF TYPE ‘X’ GYPSUM BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING.
10
12' - 8" A.F.F. FR LOUNGE T.O. ARCH
(2) LAYERS 3/8" FRT PLYWOOD BLOCKING TO SECURE DECORATIVE SUSPENDED LIGHTING
NON-HARDENING, RESILIENT ACOUSTIC CAULKING, SEALED AIRTIGHT AT PENETRATION, TYP.
SEALANT
12' - 10 3/4" A.F.F. EXISTING CEILING V.I.F. CONCEALED J-BOX FOR SUSPENDED DECORATIVE LIGHTING
BASE AS SCHEDULED
11
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
FINISHED CEILING
4' - 0"
4' - 0" 8' - 0"
CHECKED BY: JSP AREA: 1807 SQ.FT
NOTES:
#
ISSUE
DATE
1. NO RIGID CONNECTION TO LANDLORD'S SLAB OR ACOUSTIC CEILING. ANY PENETRATIONS MADE TO LANDLORD'S ACOUSTIC CEILING ARE TO BE PACKED WITH INSULATION AND SEALED WITH FLEXIBLE CAULKING TO MAINTAIN THE ACOUSTIC RATING. IF ANY ADDITIONAL ACCESS IS REQUIRED IN ADDITION TO THE EXISTING ACCESS PANELS LOCATED WITHIN THE SPACE, G.C. IS TO OPEN AS REQUIRED AND THEN PATCH BACK WITH (2) LAYERS OF 5/8"THK TYPE 'X' GYP. BOARD TO RESTORE THE ACOUSTIC RATING OF THE CEILING
1
ISSUE FOR PERMIT
09/07/2018
2. G.C. TO CONFIRM BATT INSTALLATION INSTALLED ABOVE LANDLORD'S (2) LAYER GYP. BOARD CEILING 3. NO RIGID CONNECTION BETWEEN ISOLATED CEILING, COLUMNS, DUCTWORK, WALLS OR PERIMETER FASCIA AT STOREFRONT, USE KINETICS SRP PERIMETER ISOLATION BOARD AND SEAL WITH NONHARDENING, RESILIENT ACOUSTIC CAULKING, TYP.
CONSTRUCTION AND CEILING DETAILS
A-502.00 SHEET 24 OF 27
ARCHITECT OF RECORD:
VARIES
EXISTING V.I.F.
NEW FINISHED FLOOR AS SCHEDULED 0' - 0" A.F.F. 4 7/8"
FINISHED FLOOR NOTE: BASE AS SCHEDULED
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE • (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD AT CEILING EXTEND GYP. BOARD 6" ABOVE CEILING AT LOCATIONS OPEN TO DECK ABOVE EXTEND GYP. BOARD TO DECK NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES
VARIES REF. RCP
2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY
B
NEW FINISHED FLOOR AS SCHEDULED
NEW FINISHED FLOOR AS SCHEDULED
0' - 0" A.F.F.
0' - 0" A.F.F.
FINISHED FLOOR
FINISHED FLOOR 4 1/4"
NOTE: BASE AS SCHEDULED
WALL TYPE "B" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT •
•
C
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING
WALL TYPE "C" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT •
•
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
D
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS EXTEND GYP. BOARD 6" ABOVE CEILING
•
NEW FINISHED FLOOR AS SCHEDULED
0' - 0" A.F.F.
0' - 0" A.F.F.
FINISHED FLOOR
FINISHED FLOOR 4 7/8"
NOTE: BASE AS SCHEDULED
E
6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING
WALL TYPE "E" - INTERIOR NON-LOAD BEARING PARTITION - PLUMBING •
•
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
CONTINUOUS METAL TRACK
NEW FINISHED FLOOR AS SCHEDULED
NOTE: BASE AS SCHEDULED
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP
CONTINUOUS METAL TRACK
WALL TYPE "D" - INTERIOR NON-LOAD BEARING PARTITION •
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE
6" METAL STUD, SPACED AT 16" O.C. TYP
FINISHED FLOOR 7 1/4"
T.O. PARTIAL HEIGHT WALL
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD; ONE SIDE ONLY (USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS, REF. PLAN)
6" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK NEW FINISHED FLOOR AS SCHEDULED 0' - 0" A.F.F.
NOTE: BASE AS SCHEDULED
MEP ENGINEER:
9' - 0" A.F.F.
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD AT TOP; FINISH TO MATCH ADJ. WALL FINISH
B.O. CEILING
B.O. CEILING 2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP (1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE
3 5/8" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK
UNDERSIDE OF FINISHED CEILING, REFER TO RCP
VARIES REF. RCP
VARIES REF. RCP
B.O. CEILING
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE; EXTEND GYP. BOARD TO DECK ABOVE AT LOCATION'S WITH NO CEILING, TYP.; REF. RCP 3 5/8" METAL STUD, SPACED AT 16" O.C. TYP CONTINUOUS METAL TRACK
•
BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
B.O. EXG CLG
F
6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO 6" ABOVE CEILING AND BRACE TO STRUCTURE ABOVE WITH 3 5/8" METAL STUDS AT 4'-0" O.C. ALTERNATING SIDES. REF. A-500 FOR PARTITION FRAMING SCHEDULE AND BRACING DETAILS. (1 LAYER) 5/8" TYPE "X" GYP. BOARD, ONE SIDE ONLY INSTALL GYP. BOARD AT TENANT SIDE ONLY; DO NOT INSTALL GYP. BOARD AT INACCESSIBLE VOID CONDITIONS EXTEND GYP. BOARD 6" ABOVE CEILING USE MOISTURE RESISTANT GYP. BOARD AT ALL WET WALLS
NOTE: BASE AS SCHEDULED
WALL TYPE "F" - INTERIOR NON-LOAD BEARING PARTITION - PARTIAL HEIGHT • •
3 5/8" METAL STUDS, SPACED AT MAX. 16" O.C., REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD PROVIDE GYP. BOARD AT TOP OF PARTIAL HEIGHT PARTITION AND FINISH TOP OF PARTITION TO MATCH WALL FINISH
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
VARIES REF. RCP
WALL TYPE "A" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT
BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES
B.O. CEILING
B.O. CEILING
A
BRACE TO STRUCTURE ABOVE AT 4'-0" O.C., ALTERNATING SIDES VARIES REF. RCP
2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING
4 7/8"
SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
. 6"
B.O. EXISTING CEILING
UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP
SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
. 6"
VARIES REF. RCP
SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
6" .
SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP.
. 6"
. 6"
B.O. DECK UNDERSIDE OF EXISTING DECK
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
1/2" SOUND ISOLATED DECK SUSPENDED CEILING HANGER TO REMAIN, TYP. EXISTING V.I.F.
REF. A-100 FOR PARTITION TYPE 4" TALL RUBBER WALL BASE, SCARIFY SURFACE BEHIND BASE ONLY PRIOR TO INSTALLATION B-02
B.O. DECK UNDERSIDE OF EXISTING DECK
BOH
VARIES REF. RCP
4"
7"
. 6"
6"
NEW FLOOR FINISH AS SCHEDULED; REF. A-104
B.O. CEILING 2" THK NOMINAL LUMBER FIRE BLOCKING IN WALL AT LEVEL OF DROPPED CEILING UNDERSIDE OF FINISHED CEILING, VARIES REF. RCP 1"
(1) LAYER OF 5/8" TYPE 'X' GYP. BOARD EACH SIDE
SCRIBE
STAMP HERE:
B-01
6" METAL STUD, SPACED AT 16" O.C. TYP
PAINTED WOOD TRIM FOR WALL BASE BY G.C.
CONTINUOUS METAL TRACK NEW FINISHED FLOOR AS SCHEDULED
5
0' - 0" A.F.F.
TRIM PROFILES SCALE: 6" = 1'-0"
2
B-02 WALL BASE 02 SCALE: 3" = 1'-0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
FINISHED FLOOR
D
3/4"THK PLYWOOD SUBFLOOR
WALL TYPE "G" - INTERIOR NON-LOAD BEARING PARTITION - FULL HEIGHT • •
6" METAL STUDS, SPACED AT MAX. 16" O.C., EXTEND TO UNDERSIDE OF DECK , REF. A-500 FOR PARTITION FRAMING SCHEDULE (1 LAYER) 5/8" TYPE "X" GYP. BOARD, EACH SIDE OF STUD EXTEND GYP. BOARD 6" ABOVE CEILING
REF. A-104 FOR TRANSITION FINISHES
TILE COVE BASE B-03
WALL BASE AS SCHEDULED; REF. A-104 FLOOR FINISH PLAN
RESTROOM
NEW 5/8"THK GLUE DOWN WOOD FLOOR WHERE SCHEDULED; REF. A-104 FLOOR FINISH PLAN
NEW TILE FLOOR AS SCHEDULED; REF. A-104 T-01 CONTINUOUS VAPOR BARRIER
WOOD SLEEPERS SPACED @ 24" O.C. EXISTING CONCRETE SLAB, G.C. TO PREP FOR NEW FLOOR FINISHES AS SCHEDULED C-EXG
DATE: 08/20/2018
REF. A-100 FOR PARTITION TYPE
1/2"
PAINTED WOOD BASE SCRIBE BASE TO FLOOR B-01 PT-01B
CHECKED BY: JSP AREA: 1807 SQ.FT
SALES
NEW FLOOR FINISH AS SCHEDULED; REF. A-104
EXISTING CONCRETE SLAB TO REMAIN
PROVIDE WALL BASE AS SCHEDULED REF. A -104 FINISH PLAN
16
SCALE: 1 1/2" = 1'-0"
7
THRESHOLD I SCALE: 3" = 1'-0"
4
B-03 WALL BASE 03 SCALE: 3" = 1'-0"
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
PARTITION, TRIM, AND THRESHOLD DETAILS
NOTE: ALL GYP. BOARD SHALL BE TAPED AND MUDDED TO LEVEL 4 FINISH, READY FOR NEW PAINT FINISH, REF. A-104 FINISH PLAN. REF. ELEVATIONS FOR IN-WALL F.R. BLOCKING REQUIREMENTS.
PARTITION TYPES
DRAWN BY: GR, RE, NK
6"
VARIES
ALIGN
NEW 1/8"THK SCHULTER SCHIENE M-100 BRASS TRANSITION STRIP
NEW PORCELAIN WALL TILE W/ BULLNOSE TRIM T-02
1"
SCRIBE PLANK TO CONCRETE AT TRANSITION EDGE
EDGE OF STOREFRONT DISPLAY PLATFORM; REF A-501 FOR DETAIL
PROJECT NO.: 218231
7"
TRANSITION
REF. A-100 FOR PARTITION TYPE
6"
EDGE OF TRANSITION
4'-0" MIN.
7 1/4"
1
B-01 WALL BASE 01 SCALE: 3" = 1'-0"
A-600.00 SHEET 25 OF 27
*SEE DOOR SWING DIRECTION ON CONSTRUCTION PLAN, TYP.
--
EX'G
EX'G
7/A-602
--
--
EXISTING DOOR AND HARDWARE TO REMAIN; G.C. TO CLEAN AND PROVIDE NEW BESTLOCKS
1 3/4"
2' - 0 1/4"
1 3/4"
1/16" 2' - 0" 3/16"
F
05
06
3
3'-0"
7'-0"
1 3/4"
4/A-602
HOLLOW METAL
PT-01B
4
3'-0"
7'-0"
1 3/4"
4/A-602
BOH BLIND DOOR
PAINTGRADE WOOD
FITTING ROOM BLIND DOOR
PAINTGRADE WOOD
PT-01A
PT-01A
5
6
2'-0"
2'-0"
7'-0"
7'-0"
1 3/4"
1 3/4"
5/A-602
6/A-602
10/A-602
--
F/I BY G.C.
11/A-602
HOLLOW METAL
PT-01B
11/A-602
--
--
F/I BY G.C.
12/A-602
HOLLOW METAL
PT-01B
12/A-602
--
--
F/I BY G.C.
13/A-602
PAINTGRADE WOOD
15/A-602
PAINTGRADE WOOD
1/8"
PT-01B
PT-01A
PT-01A
13/A-602
15/A-602
--
--
--
F/I BY G.C.; G.C. TO SUBMIT SHOP DRAWINGS FOR APPROVAL
--
F/I BY G.C.; G.C. TO SUBMIT SHOP DRAWINGS FOR APPROVAL
PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN
NEW EDGE PULL AT FITTING ROOM SIDE ONLY
3"
NEW PULL PLATE BOH SIDE ONLY
NEW PULL PLATE AT CLOSET SIDE ONLY
4' - 0"
PT-01B
HOLLOW METAL
5/8"
HOLLOW METAL
10/A-602
1 3/4"
4/A-602
NEW KICK PLATE AT BOH SIDE ONLY
2' - 4 1/4"
E
1 3/4"
3' - 3"
DOOR TO BOH
7'-0"
3' - 3"
04
3'-0"
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
MEP ENGINEER:
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
DOOR
D
2
7' - 0"
03
PT-01B
RESTROOM SIGNAGE AS PER LOCAL CODE REQUIREMENTS
PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR
PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN
CHAMFER WALL BASE AT HINGE SIDE
WALL BASE AS SCHEDULED FITTING ROOM (PULL)
STOREFRONT DISPLAY WINDOW PLATFORM
WALL BASE AS SCHEDULED
5/8"
C
DOOR TO CLOSET
HOLLOW METAL
7' - 0 3/4"
02
DOOR TO RESTROOM
DOOR
PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR
DOOR B
DOOR @ BOH
1/8"
SIGNAGE
1/8" 2' - 0" 1/8"
1/8"
F.R.
1/8" 2' - 0 1/2" 1/8"
1 1/2"
--
THRESHOLD
1 1/2"
7' - 0 3/4"
10'-1" V.I.F.
FINISH
2' - 0 1/4"
7' - 0"
1
1 3/4" V.I.F.
MATERIAL
NOTES *F/I = FURNISH & INSTALL
1 1/2"
5/8"
EX'G
2 LEAVES 3' - 2 1/4" V.I.F.
THK
HEAD DETAIL
1"
DOOR
METAL / GLASS
WIDTH
JAMB DETAIL
1/2"
EX-01
STOREFRONT ENTRY DOOR
FINISH
SIZE HEIGHT
1"
DESCRIPTION MATERIAL
HARDWARE SET
7' - 0"
A REF. A-201
DOOR NO.
REMARKS
7' - 1 1/4"
TYPE DOOR
FRAME
2' - 0 3/4" 1/2"
9' - 6 1/2"
DOOR
ARCHITECT OF RECORD:
1"
DOOR
DOOR SCHEDULE
NEW KICK PLATE AT PUSH SIDE ONLY
EXTEND DISPLAY PLATFORM INTO DOOR OPENING
STOREFRONT DISPLAY WINDOW (PUSH)
BOH (PULL)
DOOR TYPE "F"
DOOR TYPE "E"
DOOR HARDWARE SCHEDULE
MOUNT CLOSER AT BOH SIDE
1/8"
3' - 0"
2" 2" PAINTED HOLLOW METAL DOOR FRAME PT-01B
1/8"
KICK PLATE: (1) IVES 8400 - 10"X34"; NMH-A; FINISH: US4 SATIN BRASS
3' - 0 1/4" 1/8"
PAINTED HOLLOW METAL DOOR
1/8"
DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: 696 SATIN BRASS
2"
DOOR
2"
HINGES: (3 PAIR) EMTEK 96415 4 1/2"x4 1/2"; FINISH: SATIN BRASS US4
3' - 0 1/4"
3' - 0" DOOR
PAINTED HOLLOW METAL DOOR
3"
DOOR
NEW DEADLOCK W/ THUMBTURN AT CLOSET SIDE
3"
DOOR
7' - 0"
7' - 0 3/4"
SILENCERS: (3) IVES SR66; FINISH: WHITE
2" PAINTED HOLLOW METAL DOOR FRAME PT-01B
1/8"
NEW DEADLOCK W/ THUMBTURN AT BOH SIDE
FLOOR STOP: (1) IDH 'LOW PROFILE DOME' STOP 13060; FINISH: 004 SATIN BRASS
MOUNT CLOSER AT CLOSET
2"
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
2"
2"
LEVERSET: (1 SET) SCHLAGE F40 LAT 608, LATITUDE PRIVACY LEVERSET; FINISH: 608 SATIN BRASS
1/8"
NOTE: EXISTING HARDWARE TO REMAIN; G.C. TO PROVIDE NEW BESLOCKS AND 6 SETS OF KEYS
7' - 0"
SET #2 - DOOR TO RESTROOM
7' - 0 3/4"
SET #1 - STOREFRONT ENTRY DOORS
LEVERS: (1) SCHLAGE F170 LAT 608, LATITUDE DUMMY LEVER FINISH: 608 SATIN BRASS
LEVERS: (2) SCHLAGE F170 LAT 622, LATITUDE DUMMY LEVER; FINISH: 622 MATTE BLACK
DEADLOCK: (1 SET) SCHLAGE B560R, ADA COMPLIANT SINGLE CYLINDER WITH INTERCHANGEABLE CORE; PROVIDE 6 SETS OF KEYS FINISH: 606 SATIN BRASS
DEADLOCK: (1 SET) SCHLAGE B560R, ADA COMPLIANT SINGLE CYLINDER WITH INTERCHANGEABLE CORE; PROVIDE 6 SETS OF KEYS FINISH: 606 SATIN BRASS
HINGES: (3 PAIR) EMTEK 96415 4 1/2" x 4 1/2" SQUARE CORNER BRASS HINGES; FINISH: US4 SATIN BRASS
HINGES: (3 PAIR) EMTEK 96415 4 1/2" x 4 1/2" SQUARE CORNER BRASS HINGES; FINISH: US4 SATIN BRASS
DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: 696 SATIN BRASS
DOOR CLOSER: (1) CORBIN RUSSWIN DC3200-A1 REGULAR ARM MOUNT W/ HOLD OPEN; FINISH: 696 SATIN BRASS
KICK PLATE: (1) IVES 8400 - 10" x 34"; NMH-A; FINISH: SATIN BRASS US4
KICK PLATE: (1) IVES 8400 - 10" x 34"; NMH-A; FINISH: SATIN BRASS US4
SILENCERS: (3) IVES SR66; FINISH: WHITE
WALL STOP: (1) IVES WS65 US27; FINISH: ALUMINUM
NEW DUMMY LEVERS BOTH SIDES OF DOOR
BOH (PULL)
3' - 3"
NEW KICK PLATE AT PUSH SIDE ONLY
NEW DUMMY LEVER AT VESTIBULE SIDE ONLY
VESTIBULE (PUSH)
VESTIBULE (PULL)
DOOR TYPE "D"
NEW KICK PLATE AT PUSH SIDE ONLY CLOSET (PUSH)
DOOR TYPE "C"
6' - 5 3/4" 1/8" 2" ADA RESTROOM SIGNAGE, G.C. TO INSTALL PER LOCAL CODE REQUIREMENTS
3' - 0 1/4" 1/8"
3' - 0"
MOUNT CLOSER AT RESTROOM SIDE 2" PAINTED HOLLOW METAL DOOR FRAME PT-01B
2" 1/8"
DOOR
1 1/2"
SET #4 - DOOR TO BOH
3' - 2 5/8" PANEL V.I.F.
1/4"
3' - 2 5/8"
STAMP HERE:
1/8"
PANEL V.I.F.
2"
SET #3 - DOOR TO CLOSET
5/8"
5/8"
3' - 3"
NOTE: KICK PLATE TO BE INSTALLED ON PUSH SIDE ONLY; INSTALL WALL STOP ON VESTIBULE SIDE.
1/8"
PAINTED HOLLOW METAL DOOR
SILENCERS: (3) IVES SR66; FINISH: WHITE
ROLLER CATCH (1) IVES 336-B26 DOOR ROLLER CATCH
KICKPLATE: (1) IVES 8400 - 10" x 22"; NMH-A; FINISH: US32D STAINLESS STEEL
KICK PLATE: (1) IVES 8400 - 10" x 23 1/2"; NMH-A; FINISH: US32D STAINLESS STEEL WALL BUMPER (3) HAFELE 941.60.051 WALL RUBBER BUMPER FINISH: BLACK
NOTE: KICK PLATE AND PULL PLATE TO BE INSTALLED ON BACK OF HOUSE SIDE ONLY
SILENCERS: (3) IVES SR66; FINISH: WHITE
DRAWN BY: GR, RE, NK CHECKED BY: JSP #
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
NEW KICK PLATE AT PUSH SIDE ONLY VESTIBULE (PULL)
(1 PAIR) SOSS INVISIBLE SPRING HINGE #218IC FINISH: WHITE E-COAT ROLLER CATCH (1) IVES #336-B26 DOOR ROLLER CATCH
DATE: 08/20/2018
AREA: 1807 SQ.FT
HINGES: (3 PAIR) SOSS INVISIBLE HINGE #218 FINISH: WHITE E-COAT
SILENCERS: (3) IVES SR66; FINISH: WHITE
10' - 6" V.I.F.
PUSH PLATE: (1) IVES 8200 PUSH PLATE 3 1/3"W x 15"H FINISH: US32D STAINLESS STEEL
PROJECT NO.: 218231
3' - 3"
HINGES: (3 PAIR) EMTEK 95014 4" x 4" SQUARE CORNER SPRING HINGES; FINISH: US26 POLISHED CHROME
DOOR
CONCEALED EDGE PULL: (1) RAJACK HARDWARE KNIFE EDGE PULL FE158 CUSTOM FINISH: POWDER COAT TO MATCH DOOR FINISH - PT-01A
5' - 0"
PULL PLATE: (1) IVES PULL PLATE 8302; 31/2"W x 15"H PULL PLATE 8300 WITH 8102 PULL 6" CENTERS FINISH: US32D STAINLESS STEEL
7' - 0"
SET #6 - FITTING ROOM BLIND DOOR
NEW PRIVACY LEVERSET, PUSH BUTTON AT RESTROOM SIDE
5/8"
SET #5 - BACK OF HOUSE BLIND DOOR
7' - 0 3/4"
NOTE: KICK PLATE TO BE INSTALLED ON PUSH SIDE ONLY; INSTALL WALL STOP ON BOH SIDE. KEYED SIDE OF DEADBOLT TO BE INSTALLED ON CORRIDOR SIDE, THUMB-TURN AT BOH SIDE.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
RESTROOM (PUSH) DOOR TYPE "B" G.C. TO PROVIDE NEW BEST LOCKS AND 6 SETS OF KEYS
DOOR AND HARDWARE SCHEDULE
DOOR TYPE "A"
NOTE: INSTALL PULL AT FITTING ROOM SIDE OF DOOR SO THAT PULL OPENS OUT TO FITTING ROOM INSTALL PUSH PLATE AND KICK PLATE AT PUSH SIDE OF DOOR ONLY
1
DOOR TYPES SCALE: 1/2" = 1'-0"
A-601.00 SHEET 26 OF 27
15
DOOR TYPE 'F' SECTION / THRESHOLD 'H' SCALE: 3" = 1'-0"
12
T.O. DOOR FRAME
1/8"
2"
CUT BOARD
-0' - 3 1/4" A.F.F. EXISTING SLAB WOOD SLEEPERS SPACED @ 24" O.C. CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.
EXISTING SLAB TO REMAIN
9
THRESHOLD 'C'
2"
VESTIBULE (PULL)
3/8"
NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02
5/8"
NEW 5/8"THK WOOD FLOOR WF-01 3/4"THK PLYWOOD SUBFLOOR 0' - 0" A.F.F.
CHANGE FLOOR PATTERN
START OF CONCRETE TOPPING
(ALIGNS W/ TRANS EDGE)
(ALIGNS W/ TRANS EDGE)
5/8" THK WOOD PLANK CUT TO SIZE AT THRESHOLD TO ALIGN WITH BOTH SIDES OF TRANSITION OPENING
-0' - 3 1/4" A.F.F. STOREFRONT WINDOW DISPLAY (PUSH)
EXISTING SLAB WOOD SLEEPERS SPACED @ 24" O.C.;TYP. CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.
EQ 1 1/8"
4 7/8"
ALIGN
1 3/4"
2' - 0" DOOR 1/16"
EDGE OF TRANSITION VARIES
NEW 5/8"THK WOOD FLOOR WF-01
FITTING ROOM (PULL)
3/4"THK PLYWOOD SUBFLOOR
3"
2 1/8"
CUT BOARDS
EDGE PULL; REF. DOOR HARDWARE SCHEDULE
SCALE: 3" = 1'-0"
EXISTING SLAB
WOOD SLEEPERS SPACED @ 24" O.C. TYP. CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.
EXISTING SLAB TO REMAIN
NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02
PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR
13 A-602.00
PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN
BACK OF HOUSE (PULL)
2'-4 1/4" ROUGH OPENING 1/2"
WALL RUBBER BUMPER
1/2"
1" 1/2" 1/8"
WALL BASE AS SCHEDULED BELOW; EXTEND IN FRONT OF DOOR FRAME B-01
1/8"
2' - 0 1/2" (@ B.O.H. SIDE)
SHIM AS REQ'D
1" 5/8" TYPE 'X' GYP. BOARD
PULL PLATE, REF. DOOR HARDWARE SCHEDULE BLOCKING AS REQ'D
HINGE; REF. DOOR HARDWARE SCHEDULE
ALIGN
WOOD FLOOR -0' - 0 3/8" A.F.F. RAISED SLAB -0' - 3 1/4" A.F.F.
WALL BASE AS SCHEDULED BELOW; EXTEND IN FRONT OF DOOR FRAME AND PROVIDE BASE AT FACE OF DOOR
DOOR TYPE "F" PLAN DETAIL - FITTING ROOM BLIND DOOR
0' - 0" A.F.F.
2 1/8"
3/16"
G.C. TO CHAMFER WALL BASE BELOW @ 45 ANGLE AT HINGE SIDE OF DOOR AND ADJ WALL; PAINT ALL VISIBLE SURFACES TO MATCH ADJ BASE
NEW 1/8"THK SCHULTER SCHIENE M-100 BRASS TRANSITION STRIP NEW 3/8"THK POLISHED CONCRETE TOPPING, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-01
1 3/4" ALIGN
DOUBLE 20 GA. METAL STUDS @ JAMB
ALIGN 1 1/2"
1/8"
2' - 0" DOOR (@ STOREFRONT SIDE)
G.C. TO CHAMFER WALL BASE BELOW @ 45 ANGLE AT HINGE SIDE OF DOOR AND ADJ WALL; PAINT ALL VISIBLE SURFACES TO MATCH ADJ BASE
1/8"
5/8" TYPE 'X' GYP. BOARD. WALL BASE AS SCHEDULED BELOW; EXTEND IN FRONT OF DOOR FRAME AND PROVIDE BASE AT FACE OF DOOR
1 1/2"
STOREFRONT DISPLAY WINDOW (PUSH)
NOTE: G.C. TO HANG SHORTER DOOR AT STOREFRONT SIDE; REF. DOOR ELEVATIONS
EQ
EXISTING SLAB BELOW TO REMAIN
REF. A-104 FOR TRANSITION FINISHES
TRANSITION
PAINTED WOOD WALL BASE B-01 PT-02
WOOD FLOOR -0' - 0 3/8" A.F.F. RAISED FLOOR
BLOCKING AS REQ'D
EXTEND DISPLAY PLATFORM INTO DOOR OPENING AND ALIGN WITH FACE OF FRAME
SCRIBE PLANK TO CONCRETE AT TRANSITION EDGE HOLLOW METAL DOOR PAINTED PT-01B
FISKAA ENGINEERING 589 EIGHTH AVENUE NEW YORK, NY 10018 T 212 736 9600 F 212 736 9020 WWW.FISKAA.COM
5/8" TYPE 'X' GYP. BOARD.
6
SCALE: 3" = 1'-0"
5/8" TYPE 'X' GYP. BOARD
DOUBLE 20 GA. METAL STUDS @ JAMB
CONCEALED HINGES; REF. DOOR SCHEDULE
VARIES REF. PLAN
MEP ENGINEER:
EQ
WOOD FLOOR
1/8"
KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE
SCHULTER RENO-MTK 125 ADA COMPLIANT THRESHOLD
7' - 0" DOOR
1"
G.C. TO SHIM AS REQ'D
CLOSET (PUSH)
PAINT GRADE SOLID CORE WOOD CORE; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN
B.O.H. (PULL)
3 5/8" DOUBLE METAL STUD LINTEL
2 7/8"
1"
EQ
WALL RUBBER BUMPER
ALIGN
1"
1/2"
1"
1 1/2"
9' - 6 1/2" A.F.F.
WOOD FLOOR -0' - 0 3/8" A.F.F.
HOLLOW METAL DOOR FRAME PAINTED PT-01B
7' - 0" DOOR
SHIM AS REQ'D
0' - 0" A.F.F.
SCALE: 3" = 1'-0"
2"
3 5/8" METAL TRACKS
0' - 0" A.F.F.
DOOR TYPE 'D' SECTION / THRESHOLD 'F'
1/2" 1 3/4"
SHIM AS REQ'D
WALL BASE AS SCHEDULED BELOW; B-01
NEW 5/8"THK WOOD FLOOR WF-01 3/4"THK PLYWOOD SUBFLOOR
EXISTING SLAB
5/8"
PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR
SINGLE 5/8" THK WOOD PLANK CUT TO SIZE AT THRESHOLD TO ALIGN WITH BOTH SIDES OF TRANSITION OPENING
WOOD SLEEPERS SPACED @ 24" O.C.; TYP.
3 5/8" METAL TRACKS
3 5/8" DOUBLE METAL STUD LINTEL
VARIES
-0' - 3 1/4" A.F.F.
3 5/8" METAL FRAMING
3 5/8" METAL FRAMING
PAINTED WOOD WALL BASE B-01 PT-02
RAISED FLOOR
EXISTING SLAB BELOW TO REMAIN
1' 11 1/4" V.I.F.
EDGE OF TRANSITION
3/4"THK PLYWOOD SUBFLOOR
CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.
1/2" x 1 1/8" PAINTED WOOD DOOR STOP; FINISH TO MATCH DOOR FRAME
PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR
42 CROSBY STREET, SUITE 1B NEW YORK, NY 10012
EXISTING SLAB
1/2"
1/2" 1 3/4" 1/2"
4"
-0' - 3 1/4" A.F.F.
2'-3 3/4" ROUGH OPENING
7/8"
CUT BOARD
STORAGE CLOSET (PUSH)
1" 3/4"
4 7/8"
NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02
2 7/8"
WOOD FLOOR
TRANSITION
NEW 5/8"THK WOOD FLOOR WF-01
0' - 0" A.F.F.
REF. A-104 FOR TRANSITION FINISHES
PAINT GRADE SOLID CORE WOOD DOOR; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1"
APPLY WALL BASE AS SCHEDULED TO FITTING ROOM SIDE OF DOOR
(ALIGNS W/ TRANS EDGE)
KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE
VESTIBULE (PUSH)
SCHULTER RENO-MTK 125 ADA COMPLIANT THRESHOLD
(ALIGNS W/ TRANS EDGE)
ALIGN
FITTING ROOM (PULL)
BOH (PULL)
CHANGE FLOOR PATTERN
ALIGN
PAINT GRADE SOLID CORE WOOD CORE; REF. DOOR SCHEDULE, FINISH TO MATCH ADJ SURFACE; REF. FINISH PLAN
HOLLOW METAL DOOR PAINTED PT-01B
CHANGE FLOOR PATTERN
ALIGN
ALIGN 5/8"
KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE
ALIGN
STORAGE CLOSET (PULL)
G.C. TO SHIM AS REQ'D
ALIGN
EQ
7' - 0" DOOR
1 1/8"
15 A-602.00
5/8"
1 3/4"
1/2"
EQ
3 5/8" DOUBLE METAL STUD LINTEL
T.O. DOOR FRAME
1/8"
1 3/4"
G.C. TO SHIM AS REQ'D
HOLLOW METAL DOOR FRAME PAINTED PT-01B
3 5/8" METAL TRACKS
1/8"
3 5/8" DOUBLE METAL STUD LINTEL
3 5/8" METAL FRAMING
7' - 0" DOOR
3 5/8" METAL TRACKS
ARCHITECT OF RECORD:
2"
PAINTED WOOD DOOR FRAME; FINISH TO MATCH ADJ FINISH, REF. FINISH PLAN; TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT ALL 3 SIDES OF DOOR FRAME AT BOTH SIDES OF DOOR 7' - 2 1/2" A.F.F.
3/8" 5/8"
3 5/8" METAL FRAMING
11
3 5/8" DOUBLE METAL STUD LINTEL
KICK PLATE, AT PUSH SIDE ONLY REF. DOOR HARDWARE SCHEDULE
TAPE SPACKLE AND SAND SMOOTH TO CONCEAL JOINT AT DOOR FRAME
WHITE MARBLE SADDLE, CENTERED ON DOOR FRAME MS-01 RESTROOM (PUSH)
-0' - 0 3/8" A.F.F. RAISED SLAB NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02
-0' - 3 1/4" A.F.F. EXISTING SLAB
EXISTING SLAB TO REMAIN
13
DOOR TYPE 'E' SECTION / THRESHOLD 'G' SCALE: 3" = 1'-0"
HOLLOW METAL DOOR PAINTED PT-01B
CONTINUOUS VAPOR BARRIER NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB SLOPE TO DRAIN AT RESTROOM C-02 EXISTING SLAB BELOW TO REMAIN
10
VESTIBULE (PULL)
NEW 5/8"THK WOOD FLOOR WF-01 5/8"
NEW TILE FLOOR T-01 GROUT "MAPEI" COLOR: TBD (COORD. THICKNESS REQ'D W/ TILE MANUFACTURER RECOMMENDATIONS
EXISTING METAL STOREFRONT DOOR FRAME TO REMAIN
EXISTING STOREFRONT DOOR TO REMAIN
FR HOLLOW METAL DOOR FRAME
1:48 MAX SLOPE
0' - 0" A.F.F. WOOD FLOOR -0' - 0 3/8" A.F.F.
0' - 0" A.F.F. WOOD FLOOR & TILE FLOOR
RAISED SLAB -0' - 3 1/4" A.F.F. EXISTING SLAB
-0' - 3 1/4" A.F.F. EXISTING SLAB WOOD SLEEPERS SPACED @ 24" O.C.; TYP. EXISTING SLAB TO REMAIN
7
THRESHOLD 'A' SCALE: 3" = 1'-0"
2"
5/8"
5/8"
2"
5/8" TYPE 'X' GYP. BOARD
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218231 DATE: 08/20/2018
NEW 3/8"THK POLISHED CONCRETE TOPPING, G.C. TO FLOAT TOPPING AROUND DOOR TO ENSURE SURFACE ALIGNS WITH ENTRY THRESHOLD C-01
EXISTING SLOPED EXTERIOR SIDEWALK TO REMAIN
CONTINUOUS VAPOR BARRIER INSTALLED OVER EXISTING SLAB AT ALL WOOD FLOOR LOCATIONS, TYP.
WALL BASE AS SCHEDULED BELOW
NEW 3/8"THK REMOVABLE WALK-OFF MAT CPT-02
EXISTING ADA COMPLIANT THRESHOLD TO REMAIN
3/4"THK PLYWOOD SUBFLOOR
DOOR TYPE 'B' SECTION / THRESHOLD 'D' SCALE: 3" = 1'-0"
SCALE: 3" = 1'-0"
(PUSH)
LEASE LINE
FLOAT TILE FLOOR UP TO MEET THRESHOLD
BOH WALL BASE AS SCHEDULED B-02
STAMP HERE:
HOLLOW METAL DOOR FRAME PAINTED PT-01B
3 5/8" METAL TRACKS
G.C. TO SHIM AS REQ'D
5
SCALE: 3" = 1'-0"
DOOR TYPE "E" PLAN DETAIL - BOH BLIND DOOR
2"
DISPLAY PLATFORM & B.O. EX'G MULLION
8
THRESHOLD 'B'
1/8"
2' - 5" A.F.F.
3 5/8" METAL FRAMING
7' - 0" DOOR
DISPLAY PLATFORM BY G.C.; G.C. TO EXTEND PLATFORM INTO DOOR OPENING
2"
5/8"
1 1/2"
1"
SCALE: 3" = 1'-0"
5/8"
KICK PLATE, AT BOH SIDE ONLY REF. DOOR HARDWARE SCHEDULE
DOOR TYPE 'C' SECTION / THRESHOLD 'E'
SHIM AS REQ'D
DRAWN BY: GR, RE, NK
DOUBLE 20 GA. METAL STUDS @ JAMB
CHECKED BY: JSP
BLOCKING AS REQ'D
HOLLOW METAL DOOR; REF. DOOR SCHEDULE
2"
3'-0" DOOR 1/8"
NEW 2 7/8"THK RAISED LIGHTWEIGHT CONCRETE SLAB, G.C. TO ENSURE SMOOTH LEVEL FINISH WITHIN 1/4" OVER 10'-0" C-02
4
DOOR TYPE 'B'/'C'/'D' PLAN DETAIL SCALE: 3" = 1'-0"
#
ISSUE
DATE
1
ISSUE FOR PERMIT
09/07/2018
5/8" TYPE 'X' GYP. BOARD (TO BE WATER-RESISTANT AT WET WALLS)
WALL BASE AS SCHEDULED BELOW HINGE; REF. DOOR HARDWARE SCHEDULE
AREA: 1807 SQ.FT
(PULL)
2" 1/8"
PEMKO PK33W FIRE GASKETTING, TYP. LEVERSET, REF. DOOR HARDWARE SCHEDULE
DOOR AND THRESHOLD DETAILS
A-602.00 SHEET 27 OF 27
CONTACT LIST
DRAWING LIST
ABBREVIATIONS
ARCHITECT OF RECORD:
ISSUE
DAN KLACIK EMAIL: DKLACIK@BONOBOS.COM M: 908-801-0655 SAM HELLWEGE EMAIL: SHELLWEGE@BONOBOS.COM M: 646-460-3602
OWNER'S REPRESENTATIVE
O'NEIL LANGAN 15 WEST 37TH STREET 15TH FLOOR NEW YORK, NY 10018 JENNIFER SCHIAVONE-PALMA EMAIL: JENNIFER@OLARCH.COM P: 212-279-2670 x 240 STEVE O'NEIL EMAIL: STEVE@OLARCH.COM P: 212-279-2670 x 231
STANDARD FIXTURE PACKAGE 2018 A.01 NON-ILLUMINATED MIRROR - TYP.
F.02 - WALL MOUNTED DISPLAY BUNK
A.02 NON-ILLUMINATED MIRROR - LARGE
SHEET T-000 A-401 A-402 A-403 A-404 A-405 A-406 A-407 A-408 A-409 A-410 A-411 A-412 A-413 A-414 A-415 A-416 A-417 A-418 A-419 A-420
F.06 SALES JUNGLE GYM
A.03 FITTING ROOM MIRROR
F.03 - FREE STANDING RACK 1
F.07 MONDRIAN SCREEN
A.04 3-WAY MIRROR
F.04A - FREE STANDING RACK 2A F.04B - FREE STANDING RACK 2B (W/ SHELF)
F.08 GLASS AND BRASS STAND
SHEET TITLE COVER SHEET NON-ILLUMINATED MIRROR (A.01 & A.02) FITTING ROOM MIRROR (A.03) 3-WAY MIRROR (A.04) WALL MOUNTED FOCAL (F.01) WALL MOUNTED FOCAL (F.01) WALL-MOUNTED BUNK (F.02A, F.02B, F.02C) WALL-MOUNTED BUNK (F.02A, F.02B, F.02C) WALL-MOUNTED BUNK (F.02A, F.02B, F.02C) FREE-STANDING RACK 1 (F.03) FREE-STANDING RACK 2A (F.04A) FREE-STANDING RACK 2B (F.04B) STANDING RACK (F.05) JUNGLE GYM (F.06) OPTION A JUNGLE GYM (F.06) OPTION B JUNGLE GYM (F.06) OPTION C JUNGLE GYM (F.06) OPTION D MONDRIAN SCREEN (F.07) GLASS AND BRASS STAND (F.08) ADA FITTING ROOM BENCH (F.09) ADA FITTING ROOM BENCH (F.09)
2018 STANDARD FIXTURE PACKAGE
ROB QUELLMALZ EMAIL: RQUELLMALZ@BONOBOS.COM M: 646-710-3821
ISSUED FOR BID
JOSH BAILEY EMAIL: JBAILEY@BONOBOS.COM M: 512-925-3470
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
10/24/2018
LIZ WASSERMAN EMAIL: L.WASSERMAN@MODCLOTH.COM
ADJ. ADJACENT A.F.F ABOVE FINISHED FLOOR A.C.T. ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT ADAAG ADA ACCESSIBILITY GUIDELINES BLK. BLOCKING CL CENTERLINE CLR. CLEAR CLG. CEILING CNTR. COUNTER CNT. CENTER CONC. CONCRETE COL COLUMN C.O.W CENTER OF WALL CPT. CARPET CONT. CONTINUOUS CONSTR. CONSTRUCTION C.G. CORNER GUARD CMU CONCRETE MASONRY UNIT DEMO DEMOLITION DWG. DRAWING DIA. DIAMETER DN. DOWN DR. DOOR ELEC. ELECTRICAL E.P. ELECTRICAL PANEL EMER. EMERGENCY EQ. EQUAL (E) EXISTING EA. EACH EXT. EXTERIOR FBO. FURNISHED BY OWNER F.C. FIXTURE CONTRACTOR F.F. FINISH FLOOR F.D. FLOOR DRAIN FR FRAME F.R.T FIRE RETARDANT TREATED F.S. FIRE EXTINGUISHER FURN. FURNISH F.O.W. FACE OF WALL GA. GAUGE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GWB. GYPSUM WALL BOARD HC HOLLOW CORE H.M. HOLLOW METAL HGT. HEIGHT HORIZ. HORIZONTAL IN INCH INST. INSTALL INSUL INSULATION KE KITCHEN EQUIPMENT L.O.D. LEASE OUTLINE DRAWING L.N. LANDLORD MAX MAXIMUM MAT'L. MATERIAL M.D.F. MAIN DISTRIBUTION FACILITY MECH. MECHANICAL MFR. MANUFACTURER MIR. MIRROR MIN. MINIMUM M.R. MOISTURE RESISTANT M.O. MASONRY OPENING N/A NOT APPLICABLE (N) NEW N.I.C. NOT IN CONTRACT NO. NUMBER N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPG. OPENING OPP. OPPOSITE PT. PAINT PLWD. PLYWOOD P-LAM. PLASTIC LAMINATE PNL. PANEL QTY. QUANTITY RCP REFLECTED CEILING PLAN RB. RUBBER BASE REINF. REINFORCING REQ'D. REQUIRED REV. REVISED/REVISION R.R. RESTROOM SC SOLID CORE SCHED. SCHEDULE SF. SQUARE FOOT SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE SUSP. SUSPENDED TEMP. TEMPERED TBD TO BE DETERMINED TBV TO BE VERIFIED TYP. TYPICAL UON UNLESS OTHERWISE NOTED V.C.T. VINYL COMPOSITE TILE V.I.F VERIFIED IN FIELD VERT. VERTICAL WD WOOD
STAMP HERE:
F.01 - WALL MOUNTED FOCAL
F.05 - STANDING RACK
F.09 ADA FITTING ROOM BENCH
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: RE, NK CHECKED BY: JSP AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
FINISH SCHEDULE FINISH CODE FB-02 GL-01 GL-02 GL-03 GL-04 GL-05 GL-06 L-02 L-03 L-04 L-05 L-06 MT-01 MT-02 MT-04 PLM-01 PT-02
DESCRIPTION FABRIC - CUSHION MIRROR CLEAR GLASS PINK GLASS LIGHT GREEN GLASS WHITE FROSTED GLASS (50% TRANSPARENT) WHITE FROSTED GLASS (20% TRANSPARENT) WHITE LAQUER ORANGE LAQUER LIGHT PINK LAQUER LIGHT GREEN LAQUER GRAY LAQUER BRASS POWDER-COATED METAL POWDER-COATED METAL PLASTIC LAMINATE INTERIOR PAINT
MANUFACTURER TBD F.C. F.C. BENDHEIM BENDHEIM BENDHEIM BENDHEIM F.C. F.C. F.C. F.C. F.C. TBD F.C. F.C. FORMICA BENJAMIN MOORE
FINISHES
TBD CLEAR REFLECTIVE MIRROR, TEMPERED CLEAR GLASS, STARFIRE TEMPERED PINK GLASS, TEMPERED LIGHT GREEN GLASS, TEMPERED WHITE FROSTED GLASS (50% TRANSPARENT) WHITE FROSTED GLASS (20% TRANSPARENT) LAQUER TO MATCH BENJAMIN MOORE CHANTILLY LACE; 2121-70 - SATIN LAQUER TO MATCH PANTONE 1645C LAQUER TO MATCH PANTONE 488C LAQUER TO MATCH PANTONE 566C LAQUER TO MATCH BENJAMIN MOORE ANCHOR GRAY 2126-30 POLISHED BRASS WITH CLEAR COAT POWDER-COATED METAL TO MATCH BENJAMIN MOORE CHANTILLY LACE; 2121-70 - SATIN POWDER COATED METAL TO MATCH PANTONE 566C COLORCORE - WHITE CHANTILLY LACE; 2121-70 - SATIN
REMARKS/NOTES
BY OWNER (MODCLOTH) /BRAD JOBE F/I BY F.C. F/I BY F.C. F/I BY F.C. F/I BY F.C. F/I BY F.C. F/I BY F.C. F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F/I BY F.C. F.C. TO PROVIDE SAMPLE FOR APPROVAL F.C. TO PROVIDE SAMPLE FOR APPROVAL F/I BY F.C. F.C. TO PROVIDE PAINT DRAW DOWNS FOR APPROVAL
2018 FIXTURE PACKAGE COVER SHEET
T-000 SHEET 1 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
8 A-401
4' - 6" (A.02) 1 1/2" 1/2" 1/8"
3' - 0" (A.01) 7/8"
4' - 5" (A.02)
1/2"
1/2"
2' - 11" (A.01)
1' - 4 1/2"
3" RADIUS AT MIRROR CORNERS; TYP.
4' - 8" (A.02)
5"
3' - 2" (A.01)
5"
Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK
Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK
1/4" THK TEMPERED MIRROR GL-01
1' - 3"
1' - 2 1/4"
IN-WALL BLOCKING AS REQUIRED
1/4" THK TEMPERED MIRROR GL-01
5" 1' - 3"
MIRROR
6' - 6"
EDGE OF FRAME BEYOND
2018 STANDARD FIXTURE PACKAGE
1' - 4 1/2"
5"
5"
1' - 2 1/4"
7' - 3"
IN-WALL BLOCKING AS REQUIRED
T.O FIXTURE
5"
MIRROR
T.O. FIXTURE
7' - 3"
6' - 6"
BRASS FRAME; FINISH TO MATCH MT-01
2' - 2 1/8"
5/8" WOOD BACKING; PAINT GRADE MDF; FINISH TO MATCH PT-01
R
HOLD
9" 0' - 0" A.F.F. FINISHED FLOOR
8
3"
WALL BASE BELOW
HOLD
9"
BRASS FRAME; FINISH TO MATCH MT-01
NON-ILLUMINATED MIRROR - SECTION
0' - 0" A.F.F. FINISHED FLOOR
5
SCALE: 1 1/2" = 1'-0"
NON-ILLUMINATED MIRROR - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
PARTITION AS SCHEDULED
PARTITION AS SCHEDULED
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218299 (1) LAYER OF TYPE 'X' GYP. BOARD; FINISH TO MATCH PT-01
5/8" WOOD BACKING; PAINT GRADE MDF; FINISH TO MATCH
3/4" FRT PLYWOOD IN-WALL BLOCKING Z-CLIP; FINISH BLACK
Z-CLIP; FINISH BLACK
4' - 6" (A.02)
3/8" 1 1/8"
1 1/2"
PT-01
BLOCKING AS REQUIRED 5/8" PLYWOOD BACKING
A-401
7
SCALE: 6" = 1'-0"
CHECKED BY: JSP
A-401
#
ISSUE ISSUE FOR BID
DATE 10/24/2018
5/8" WOOD BACKING; PAINT GRADE MDF; FINISH TO MATCH PT-01 BRASS ANGLE FRAME; FINISH TO MATCH MT-01 1/4" THK TEMPERED MIRROR
NON-ILLUMINATED MIRROR (A.01 & A.02)
1/2" THK METAL FRAME; BRASS FINISH TO MATCH MT-01
NON-ILLUMINATED MIRROR - PLAN DETAIL
5 8
PAINT REVEAL BLACK 2 1/2"
3' - 0" (A.01)
7 A-401
1/4" THK TEMPERED GLASS 1/4"
DRAWN BY: NK AREA: N/A
7/8" 5/8"
1 1/2"
3/4" FRT PLYWOOD IN-WALL BLOCKING
DATE: 10/24/2018
4
NON-ILLUMINATED MIRROR - PLAN SCALE: 1 1/2" = 1'-0"
A-401 SHEET 2 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
8 A-402
2' - 6" 3 1/4" 2 3/8"
FRAME
1/2"
7/8"
1/2"
2' - 5"
1/2"
MIRROR
3" RADIUS AT MIRROR CORNERS; TYP.
11 1/2"
EDGE OF WALL
IN-WALL BLOCKING AS REQUIRED Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK
5"
5"
Z-CLIP; FINISH BLACK
1' - 7 1/2"
1' - 8 1/4"
1/4" THK TEMPERED MIRROR GL-01
BRASS FRAME; FINISH TO MATCH MT-01
5"
6' - 6"
IN-WALL BLOCKING AS REQUIRED
T.O. FIXTURE
5"
1' - 8 1/4"
11 1/2"
5" 1' - 6 1/4"
1/2"
3"
9"
HOLD
WALL BASE BELOW
HOLD
9"
EDGE OF FRAME BEYOND
R
BRASS FRAME TO MATCH MT-01
0' - 0" A.F.F. FINISHED FLOOR
8
2018 STANDARD FIXTURE PACKAGE
A.03
1' - 7 1/2"
7' - 3"
1/4" THK TEMPERED MIRROR GL-01
FRAME
IN-WALL BLOCKING AS REQUIRED
MIRROR 5"
T.O. FIXTURE
7' - 3"
6' - 6"
5/8" WOOD BACKING
FITTING ROOM MIRROR - SECTION
0' - 0" A.F.F. FINISHED FLOOR
5
SCALE: 1 1/2" = 1'-0"
FITTING ROOM MIRROR - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
PARTITION AS SCHEDULED
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218299 DATE: 10/24/2018
3/4" FRT PLYWOOD IN-WALL BLOCKING
2' - 6"
LED LIGHT BY F.C
2 1/2"
2 1/8"
5/8" 1/4" 1 1/8"
DRAWN BY: NK CHECKED BY: JSP
2 1/4" 1"
3 1/4"
ISSUE ISSUE FOR BID
DATE 10/24/2018
BRASS FRAME TO MATCH MT-01
1/4"
BLOCKING AS REQUIRED 5/8" THK PLYWOOD BACKING
1/4" THK TEMPERED MIRROR
5 8 A-402
A-402
FITTING ROOM MIRROR (A.03)
1/4" THK TEMPERED MIRROR 1/8"
PARTION AS SCHEDULED Z-CLIP; FINISH BLACK
#
7 A-402
1/4"
2 1/4"
3 1/4"
1"
5/8" THK WOOD BACKING
1/4"
2"
AREA: N/A
Z-CLIP; FINISH BLACK 5/8" THK PAINT GRADE MDF BACKING; FINISH TO MATCH PT-01
BRASS METAL FRAME; FINISH TO MATCH MT-01
2' - 1 1/2"
2 1/8" PAINT REVEAL BLACK 2 1/2"
7
ADA/FITTING ROOM MIRROR - PLAN DETAIL SCALE: 6" = 1'-0"
4
FITTING ROOM MIRROR - PLAN SCALE: 1 1/2" = 1'-0"
A-402 SHEET 3 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
8 A-403
3 1/4" 2 3/8"
3' - 8 1/2"
5/8" 1/4" 10"
1/4"
2' - 0"
1/4"
10"
BRASS FRAME; FINISH TO MATCH MT-01 3" RADIUS AT MIRROR CORNERS; TYP.
1' - 4"
1/4" THK TEMPERED MIRROR; FINISH TO MATCH GL-01 BRASS METAL FRAME; FINISH TO MATCH MT-01
1' - 9" 1/4" THK TEMPERED MIRROR GL-01
IN-WALL BLOCKING AS REQUIRED 5"
5/8" THK WOOD BACKING
1' - 3 3/8"
1' - 3 1/2"
5"
Z-CLIP MOUNTED TO BACK OF FIXTURE; FINISH BLACK
IN-WALL BLOCKING AS REQUIRED
5"
7' - 3"
MIRROR
6' - 6"
Z CLIPS; FINISH BLACK 5" 1' - 3 3/8"
1' - 3 1/2"
EDGE OF FRAME BEYOND
2018 STANDARD FIXTURE PACKAGE
MIRROR
T.O FIXTURE
7' - 3"
6' - 6"
A.04
3"
9"
HOLD
WALL BASE BELOW
HOLD
9"
R
1' - 11 1/8"
1' - 4"
5"
5"
OLIVE KNUCKLES HINGE; BRASS FINISH TO MATCH MT-01
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR B-01 PT-01B
8
3-WAY MIRROR - SECTION
5
SCALE: 1 1/2" = 1'-0"
3-WAY MIRROR - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
PARTITION AS SCHEDULED
PARTITION AS SCHEDULED LED LIGHT BY F.C.
3/4" FRT PLYWOOD IN-WALL BLOCKING
BRASS FRAME TO MATCH MT-01
3/4" FRT PLYWOOD IN-WALL BLOCKING
3' - 8 1/2" 10"
Z-CLIP; FINISH BLACK
1/4"
2' - 0"
1/4"
Z-CLIP; FINISH BLACK CLEAR RUBBER BUMPER
10"
PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: NK CHECKED BY: JSP AREA: N/A
5/8" THK WOOD BACKING OLIVE KNUCKLES; FINISH BRASS MT-01
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
# 5/8" THK PAINT GRADE MDF BACKING; FINISH TO MATCH PT-01 3 1/4"
BLOCKING AS REQUIRED
160°
CLEAR RUBBER BUMPER 1/4"
1/8"
1/4"
5/8"
10"
2 1/4"
5/8" THK WOOD BACKING
10"
1 1/8 "
2 1/4"
1/4" 2 1/8"
BRASS ANGLE FRAME; FINISH TO MATCH MT-01
DATE 10/24/2018
OLIVE KNUCKLES HINGE; BRASS FINISH TO MATCH MT-01
3 1/4"
1"
2"
ISSUE ISSUE FOR BID
BRASS ANGLE FRAME; FINISH TO MATCH MT-01
5 7 A-403
1/4" THK MIRROR ON 5/8" PLYWOOD BACKING
8 A-403
A-403
1/4" THK MIRROR ON 5/8" PLYWOOD BACKING
3-WAY MIRROR (A.04)
PAINT REVEAL BLACK
7
3-WAY MIRROR PLAN - PLAN DETAIL SCALE: 6" = 1'-0"
4
3-WAY MIRROR - PLAN SCALE: 1 1/2" = 1'-0"
A-403 SHEET 4 OF 21
ARCHITECT OF RECORD:
11 A-404
4"
4"
2' - 6"
1' - 0"
1"THK LAQUERED WOOD SHELF L-02 WITH CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD AND SECURED TO BACK WALL WITH METAL "L" ANGLE; BRASS FINISH TO MATCH MT-01
4"
4"
1"Ø METAL TUBE PRE-WELDED TO VERTICAL TUBE TYP; BRASS FINISH TO MATCH MT-01
4"
2' - 6"
4"
1' - 0"
4"
4"
2' - 6"
4"
4"
4"
4"
1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING 4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3/4"Ø x 6"L TUBE BRACKETS CONCEALED WITHIN WALL
6"
1"Ø METAL HANG ROD W/ THREADED CONNECTION ONE SIDE AND SLEEVE CONNECTION ONE SIDE TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01
4"
1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01
9"
1' - 4"
1' - 1"
4"
1/8"Ø x 1/2"H HANG ROD PINS FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01
6"
1' - 0"
3' - 2"
1' - 1"
2' - 5"
1' - 0"
6"
4"
4"
10 A-405
1' - 1"
4"
4"
1/8"Ø x 1/2"H HANG ROD PINS FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01
6"
9"
1' - 4"
9"
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING
1' - 1"
6"
1"Ø METAL FACE-OUT HANG BAR WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG BAR PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH
4"
3' - 11"
1' - 9"
11 A-405
9"
1' - 0"
6"
CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD; BRASS FINISH TO MATCH MT-01
4"
1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
1"THK LAQUERED WOOD SHELF FINISH TO MATCH L-02
CONTINUOUS METAL "L" ANGLE; BRASS FINISH TO MATCH MT-01
1' - 0"
9"
3 1/2"
2' - 5"
4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3/4"Ø x 6"L TUBE BRACKETS CONCEALED WITHIN WALL
1' - 0 1/2"
1' - 0"
1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01
4"
1' - 4"
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
4"
1"Ø METAL THREADED HORIZONTAL CONNECTOR PRE-WELDED TO VERTICAL TUBE, TYP.; BRASS FINISH TO MATCH MT-01
6' - 5"
4"
4"
7' - 2"
6"
1' - 1"
4"
1' - 4"
9"
1' - 1"
6"
9"
4"
4"
3' - 6"
3' - 6"
3' - 6"
4"
2018 STANDARD FIXTURE PACKAGE
4' - 0"
5' - 0"
STANDARD DRESS HANG
3' - 3"
4' - 10"
4' - 3"
TOPS AND SKIRTS HANG
3' - 3"
4' - 1"
5' - 9"
MAXI DRESS HANG
5' - 7"
4' - 9"
5' - 1"
11' - 2"
PARTITION AS SCHEDULED
BASE AS SCHEDULED BELOW
BASE AS SCHEDULED BELOW
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL
11
F.01 - SECTION SCALE: 1 1/2" = 1'-0"
NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL
8
F.01 - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
11
CONTINUOUS METAL "L" ANGLE, SECURED TO WALL WITH COUNTERSUNK SCREWS SPACED @ 12" O.C.; BRASS FINISH TO MATCH MT-01
1 A-405
A-404
11' - 2" 3' - 6"
3' - 6"
3' - 6"
4"
PARTITION AS SCHEDULED
1/8"
4"
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING
DATE: 10/24/2018 3' - 5"
1"
3' - 5"
SHELF
SHELF
L-02
L-02
1 1/4"
4" 2 A-405
4 A-405
1"
4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3/4"Ø x 6"L TUBE BRACKETS CONCEALED WITHIN WALL 1"Ø METAL TUBE PRE-WELDED TO VERTICAL TUBE TYP; BRASS FINISH TO MATCH MT-01
1/8"
L-02
11"
SHELF
1" SHELF
3' - 5"
1' - 0"
1' - 4"
PROJECT NO.: 218299
1/8"
1"
1"THK LAQUERED WOOD SHELF FINISH TO MATCH L-02 CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD; BRASS FINISH TO MATCH MT-01
1"Ø METAL FACE-OUT HANG BAR WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG BAR PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01 1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01
10
SCALE: N.T.S.
7
F.01 - PLAN SCALE: 1 1/2" = 1'-0"
DRAWN BY: RE CHECKED BY: JSP AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
3 A-405
1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01 NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL
F.01 - 3D VIEW
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
WALL MOUNTED FOCAL (F.01)
A-404 SHEET 5 OF 21
ARCHITECT OF RECORD:
1"Ø METAL THREADED HORIZONTAL CONNECTOR PRE-WELDED TO VERTICAL TUBE, TYP.; BRASS FINISH TO MATCH MT-01
1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01
1"Ø METAL HANG ROD W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR ONE SIDE ONLY; BRASS FINISH TO MATCH MT-01
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1"
1/2"
1/8"Ø x 1/2"H HANG ROD PIN FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01 1/2"
1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01
1/2"
1"
1/2"
2"
3/8"
3"
NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL
F.01 - EXPLODED 3D
F.01 - END CAP PLAN - SIDE TWO
3
SCALE: N.T.S.
SCALE: 6" = 1'-0"
1"Ø METAL END CAP W/ THREADED CONNECTION TO HORIZONTAL CONNECTOR; BRASS FINISH TO MATCH MT-01
CONTINUOUS METAL 'L' ANGLE SECURED TO WALL WITH COUNTERSUNK SCREWS SPACED @ 12" O.C. MAX; BRASS FINISH TO MATCH MT-01
1' - 0 5/8" 1/8"
1"Ø METAL HANG ROD W/ END SLEEVE CONNECTION TO HORIZONTAL CONNECTOR ONE SIDE ONLY; BRASS FINISH TO MATCH MT-01
3/8" 11"
1/8" 1 1/4"
1"
WOOD SHELF SECURED TO CUSTOM EDGE CAP W/ COUNTERSUNK SCREWS; BRASS FINISH TO MATCH MT-01
9 1/4"
1/8"Ø x 1/2"H HANG ROD PIN FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01
2"
4"
1/4"
3 3/4"
1/8"
1 1/4"
1"
1/8" 1/8" 1" 1/8" 1/8"
1/2"
1"Ø METAL FACE-OUT HANG ROD SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
1/8"
9/16"
1"
1 1/4"
1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01
10 1/4"
1/8"Ø x 1/2"H HANG ROD PIN FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01
2
F.01 - END CAP PLAN - SIDE ONE
1 1/4"
1/2"
NOTE: IN-WALL BRACKETS ARE TO BE COMPLETED EARLY AND SHIPPED TO JOBSITE PRIOR TO DRYWALL INSTALL
1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01
4"
1 1/4"
3 1/4"
1/8"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
3/4"
PROJECT NO.: 218299 DATE: 10/24/2018
1"Ø METAL FACE-OUT HANG ROD SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
DRAWN BY: RE 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING PARTITION AS SCHEDULED
SCALE: 6" = 1'-0"
ISSUE ISSUE FOR BID
DATE 10/24/2018
COUNTERSUNK SET SCREW; BRASS FINISH TO MATCH
MT-01
1"
10
AREA: N/A
4"W x 48"H x 1/4" THK METAL BACK PLATE W/ 3"D x 3/4"Ø TUBE BRACKETS CONCEALED WITHIN WALL
1"Ø METAL TUBE INSTALLED OVER 6"L x 3/4"Ø BRACKET; F.C. TO CONFIRM GAUGE OF STEEL REQ'D FOR LOADING; BRASS FINISH TO MATCH MT-01
F.01 - HANG ROD SECTION
CHECKED BY: JSP #
1/4"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01
1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH
3/4"
STAMP HERE:
SCALE: 6" = 1'-0"
CUSTOM SLOTTED CONNECTOR PRE-WELDED TO FACE-OUT HANG RODS TO FIT OVER 1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01
1/8"
11"
1/8"
1/4"
1"Ø METAL TUBE BEYOND, CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01
1"Ø METAL TUBE CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01
1/4"
1/8"Ø x 1/2"L REMOVABLE HANG ROD PIN AT BACK OF HANG ROD FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01 1' - 4"
2"
1/2"
SET SCREW; BRASS FINISH TO MATCH MT-01
1"
1 1/4"
CUSTOM SLOTTED CONNECTOR PRE-WELDED TO FACE-OUT HANG RODS TO FIT OVER 1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01
1/2"
1/8"Ø x 1/2"L REMOVABLE HANG ROD PIN AT BACK OF HANG ROD FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01
1' - 2 1/2"
1/8"Ø x 1/2"H HANG ROD PINS FOR FACE-OUT LOCATIONS; BRASS FINISH TO MATCH MT-01
3/8"
1"
SET SCREW; BRASS FINISH TO MATCH MT-01
SCALE: 6" = 1'-0"
UNDERSIDE OF FACE-OUT HANG ROD NOTCHED TO FIT AROUND PIN
3"
UNDERSIDE OF FACE-OUT HANG ROD NOTCHED TO FIT AROUND PIN
F.01 - SHELF SECTION
1"
1/2"
1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01
1"THK LAQUERED WOOD SHELF; FINISH TO MATCH L-02
WOOD SHELF SECURED TO METAL 'L' ANGLE W/ COUNTERSUNK SCREWS SPACED AT 12" O.C. MAX; BRASS FINISH TO MATCH MT-01
1/2"
1/2"
1"Ø METAL TUBE BEYOND, CAPPED AT TOP AND BOTTOM; BRASS FINISH TO MATCH MT-01
6"
1"
1"
9 1/2"
1"
PARTITION AS SCHEDULED
1/2" 1/2"
CUSTOM METAL EDGE CAP TO FIT OVER 1"Ø METAL ROD; BRASS FINISH TO MATCH MT-01
1"
1"
SHELF
1/8"
1/8"
1"
11
1"Ø METAL THREADED HORIZONTAL CONNECTOR PREWELDED TO VERTICAL TUBE, TYP.; BRASS FINISH TO MATCH MT-01
2018 STANDARD FIXTURE PACKAGE
12
4
F.01 - FACE-OUT PLAN SCALE: 6" = 1'-0"
1
F.01 - WALL CONNECTION DETAIL SCALE: 6" = 1'-0"
WALL MOUNTED FOCAL (F.01)
A-405 SHEET 6 OF 21
ARCHITECT OF RECORD:
A-407
A-407
2' - 10 1/2"
1' - 3"
7' - 3"
7' - 5"
7' - 5"
6' - 9"
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
1 1/2"
3' - 3"
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3' - 2 3/4"
1 1/2"
1 1/2"
1' - 1 1/2"
DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH L-03
7" 4"
4"
4"
WALL BASE AS SCHEDULED BEYOND
1"
1"
1"
3"
7"
6"
1 1/2"
1' - 3"
1' - 3"
OPEN FRONT CUBBY W/ FINISHED BACK AND INSIDE TO MATCH L-04
1/8"
LACQUERED WOOD DRAWER SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET AND SCREWED TO METAL ANGLE AT BACK @ 12" O.C.; L-03 FINISH OUTSIDE SURFACES TO MATCH AND INSIDE SURFACES TO MATCH PLM-01
1 1/2"
ALL SURFACES OF CUBBY LACQUERED WOOD FINISH TO MATCH L-04
1' - 0" 1 1/2"
BOTTOM SHELF
1/8"
2018 STANDARD FIXTURE PACKAGE
2' - 11 3/4"
1 1/2"
1' - 8 1/8"
1' - 0"
1"
1/8"
2' - 0"
1 1/2" 1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
1' - 0"
1' - 3" PROVIDE (1) EXTRA SHELF W/ HANG WITH EACH F.02A DISPLAY BUNK W/ SHELVES IN ADDITION TO SHELF QUANTITY SHOWN
3' - 2 3/4"
1 1/2"
2' - 0"
1 1/2"
1' - 3"
1/8"
WALL BASE AS SCHEDULED 4 A-408
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
1 1/2"
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
1 1/2"
3' - 3"
1 1/2"
1' - 3"
2' - 3"
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
1 1/2"
3' - 3"
11 1/2"
1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
1' - 3" 1 1/2"
1 1/2"
1 1/2"
SHELF TYP.
1' - 4"
PROVIDE (1) EXTRA INTERMEDIATE SHELF WITH EACH F.02B DISPLAY BUNK IN ADDITION TO SHELF QUANTITY SHOWN
5' - 1 1/2"
TYP.
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
1' - 8 3/4"
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
2' - 0"
11 1/2"
6' - 3"
3/8"
9"
1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
PROVIDE (1) EXTRA SHELF W/ HANG WITH EACH F.02A DISPLAY BUNK IN ADDITION TO SHELF QUANTITY SHOWN
1 1/2"
1 1/2" 1' - 3"
5 A-408
11 1/2"
2' - 3"
1 1/2"
1' - 4"
1" 2"
1' - 3"
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
6"
1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
4' - 3"
1' - 5"
2' - 0"
1 1/2"
1' - 3"
11 1/2"
TOP SHELF
2' - 10 1/2"
1 1/2"
1 1/2"
1' - 8 3/4"
3/4"
6"
1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
1 1/2"
1"
3" 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.
1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
1 1/2" 3/8"
6"
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
7"
2' - 10 1/2"
1"
PARTITION AS SCHEDULED BY G.C.
A-406
6"
1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01
3/8"
5
1" 2"
1' - 8 3/4"
2
6"
6 A-408
11
1 1/2"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
11
DISPLAY BUNK WITH SHELVES F.02A
F.02A - SECTION W/ SHELVES SCALE: 1 1/2" = 1'-0"
1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
DISPLAY BUNK WITH SHELVES
DISPLAY BUNK WITH HANG ROD & CUBBY
F.02A
8
DISPLAY BUNK WITH HANG ROD & DRAWER
F.02B
F.02C
1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
F.02 - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01 1 1/2"
3' - 3"
1 1/2"
3' - 3" 11 1/2"
1' - 4"
1 1/2"
3' - 3"
11 1/2"
11 1/2"
1' - 4"
1 1/2" G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
11 1/2"
F.02B
11 1/4"
DISPLAY BUNK WITH HANG ROD & DRAWER
3/4"
PARTITION AS SCHEDULED BY G.C.
DATE: 10/24/2018
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
CHECKED BY: JSP
10
SCALE:
7
SCALE: 1 1/2" = 1'-0"
AREA: N/A ISSUE ISSUE FOR BID
DATE 10/24/2018
4"
#
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCHL-02
8 2 A-406
3/8"
CUSTOM CONNECTOR PRE-WELDED TO FACE-OUT HANG RODS TO FIT OVER 1"Ø METAL HANG ROD; BRASS FINISH TO MATCH MT-01 A-407
1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SUSPENDED ON 1/4"Ø HANG ROD SUPPORTS SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01
5
1"Ø METAL HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SUSPENDED ON 1/4"Ø HANG ROD SUPPORTS SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01
A-407
F.C. TO PROVIDE PRICING FOR EACH TYPE SEPARATELY (F.02A, F.02B, F.02C), PROVIDE (1) EXTRA SHELF WITH HANG FOR EACH F.02A MODULE AND (1) EXTRA INTERMEDIATE SHELF FOR EACH F.02B MODULE - IN ADDITION TO THE QUANTITY SHOWN ON THE DRAWINGS.
F.02 - PLAN
DRAWN BY: RE
8" 11 A-406
F.02 - 3D VIEW
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218299
F.02C
4 3/8"
1 1/2"
3/8"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
L-03 @ DRAWER BELOW
1' - 0"
3/4"
3/4" 11 3/8"
DISPLAY BUNK WITH HANG ROD & CUBBY
1 1/4"
F.02A
1/4"Ø HANG ROD SUPPORTS FOR FACEOUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
3 3/8"
SHELF TYP.
1' - 5"
1' - 8 3/4"
DISPLAY BUNK WITH SHELVES
1' - 9 1/8"
L-04 @ CUBBY BELOW
L-02
1' - 4"
3/8"
1 1/2"
3/4"
3/4"
WALL MOUNTED BUNK (F.02A, F.02B, & F.02C)
A-406 SHEET 7 OF 21
1' - 9 1/8"
1' - 8 3/4" SHELF W/ HANG
4"
1' - 5"
1 1/2"
PARTITION AS SCHEDULED BY G.C.
5' - 9"
1 1/2"
1 1/2"
PLM-01 INSIDE SURFACES 1' - 5 3/8"
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
1' - 8 1/8"
1' - 5 3/8"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
WALL BASE AS SCHEDULED
L-04
PARTITION AS SCHEDULED BY G.C. 3' - 6" 1 1/2"
PARTITION AS SCHEDULED BY G.C. 3' - 6" 1 1/2"
3' - 3"
1 1/2"
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
1/4" 5
1"
1 1/4"
3/4" 1 1/2"
1 1/2"
3/8" 1 1/2" 1/8"
DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH
A-407
DISPLAY BUNK CUBBY F.02B
2' - 11 3/4"
1/8"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3' - 2 3/4"
1 1/2"
1/8"
1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04
1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04
F.02C - PLAN AT DRAWER SCALE: 1 1/2" = 1'-0"
1' - 6 7/8"
1' - 4 3/4"
3/8"
1 1/4"
3' - 2 3/4"
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
L-04
SECURE DRAWER TO BACK ANGLE WITH SCREWS
F.02C
1/8"
4
DATE: 10/24/2018
1' - 5"
1/2" 1 1/8" 1/2" 3"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01 4"
3 3/4" SCALE: 6" = 1'-0"
3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.
1' - 9 1/8"
3/4" 1' - 8"
1' - 9 1/8"
1/2" 1"
DISPLAY BUNK DRAWER
3/4"
2 1/4" 7"
PARTITION AS SCHEDULED BY G.C.
9
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
PLM-01
1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
WALL BASE AS SCHEDULED
F.02C - SECTION DETAIL AT DRAWER
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
INSIDE SURFACES
SECURE DRAWER TO BACK ANGLE WITH COUNTERSUNK SCREWS
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
3/4"
1/4"
3' - 3"
F.02B
PROJECT NO.: 218299
HEAVY DUTY UNDERMOUNT DRAWER SLIDERS W/ NO SIDE BRACKETS
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
4"
3"
3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.
1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
DISPLAY BUNK WITH HANG ROD & CUBBY
F.02B - SECTION W/ CUBBY
2
SCALE: 1 1/2" = 1'-0"
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
1 1/2"
1 1/2" x 1 1/2" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
F.02C - SECTION W/ DRAWER
5
1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04
1" 1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
F.02C
1 1/2"
3/4"
1 1/2"
L-04
DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH
DISPLAY BUNK WITH HANG ROD & CUBBY
1' - 1 1/2"
INSIDE SURFACES TO MATCH PLM-01
1/2" 3/4"
11 1/2"
1/2" 1/2" 1/2"
1' - 5"
3/4"
DRAWER PULL: RESTORATION HARDWARE 8" COLLIERS PULL 24170065 BRASS FINISH
1' - 3"
3/4"
3/8"
4"
3" 1/4"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
1"
LACQUERED WOOD DRAWER SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET AND SCREWED TO METAL ANGLE AT BACK @ 12" O.C.; FINISH OUTSIDE SURFACES TO MATCH L-03 AND INSIDE SURFACES TO MATCH PLM-01
3/4" 1 1/2"
10 A-407
7"
1 1/2"
3/8"
PROVIDE (1) EXTRA INTERMEDIATE SHELF WITH EACH F.02B DISPLAY BUNK IN ADDITION TO SHELF QUANTITY SHOWN
7"
1' - 5"
1/2" 3/4"
1 1/2"
1' - 3"
WALL BASE AS SCHEDULED
1' - 0"
SCALE: 6" = 1'-0"
1' - 9 1/8"
5' - 1 1/2"
LACQUERED WOOD DRAWER SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET AND SCREWED TO METAL ANGLE AT BACK @ 12" O.C.; FINISH OUTSIDE SURFACES TO MATCH L-03 AND INSIDE SURFACES TO MATCH PLM-01
3/8"
2' - 0"
F.02B - SECTION DETAIL AT CUBBY
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
1' - 9 1/8"
3/4" 1' - 5"
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
2' - 3"
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
1' - 9 1/8"
1 1/2"
1 1/2"
TYP.
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
9 A-407
1"
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
1' - 5"
4"
1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
1 1/2"
1 1/2"
4"
WALL BASE AS SCHEDULED
1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
HANG ROD
2' - 0"
3"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
4' - 3"
2' - 3" 1 1/2"
2 1/4" 3 3/4"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
3/8"
1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
G.C. TO SECURE FRAME BY F.C. TO 3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING W/ COUNTERSUNK SCREWS; ALL SCREWS PROVIDED BY F.C., FINISH SCREWS TO MATCH MT-01
4"
1"Ø METAL FACE-OUT HANG ROD WITH 1 1/4"Ø x 1/8"THK END CAPS SECURED TO HANG ROD PINS WITH SLOTTED CONNECTOR; BRASS FINISH TO MATCH MT-01
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
SECURE CUBBY TO BACK ANGLE WITH SCREWS; FINISH TO MATCH ADJ. SURFACE L-04
1' - 4"
1 1/2"THK LACQUERED WOOD SHELF W/ HANG ROD SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
5' - 4 1/2"
1' - 4"
3/4"
2' - 0"
1" 2"
2' - 0"
3/4" 3/4" 1 1/2"
7"
3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.
1 1/2"THK LACQUERED WOOD SHELF W/ HANG ROD SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
3/4"
HANG ROD
3/4"
SHELF W/ HANG TYP.
1 1/2"
L-04
1' - 3"
1' - 0"
BACK AND INSIDE SURFACE OF LACQUERED WOOD CUBBY TO MATCH
10
1' - 8 3/4"
2018 STANDARD FIXTURE PACKAGE
9" 3/8"
3/4" CONCEALED INWALL FRT PLYWOOD BLOCKING BY G.C.
1 1/2"
3/8"
1' - 8 1/8" 9 A-408
3/4"
PARTITION AS SCHEDULED BY G.C.
1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01
3/8"
1' - 3"
7"
TOP SHELF
1' - 8 3/4"
1 1/2"
1' - 8 3/4"
10 A-408
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1"
1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01 4"
3/8"
3/8"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
3"
1' - 8 3/4"
1 1/2"
3/4"
6 A-408 SIM.
PARTITION AS SCHEDULED BY G.C.
1 1/2"THK LACQUERED WOOD CUBBY SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; CUBBY HELD FIXED IN PLACE BY ANGLE AT BACK; FINISH ALL SURFACES TO MATCH L-04
1/4"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
1" 2"
3/8"
1' - 0"
1 1/2"
7"
1' - 5"
1 1/2"
1 1/2"
1 1/2"
3/4"
ARCHITECT OF RECORD:
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
2 A-407
1
SCALE: 1 1/2" = 1'-0"
CHECKED BY: Checker AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
SECURE CUBBY TO BACK ANGLE WITH SCREWS; FINISH TO MATCH ADJACENT SURFACE L-04
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
F.C. TO PROVIDE PRICING FOR EACH TYPE SEPARATELY (F.02A, F.02B, F.02C), PROVIDE (1) EXTRA SHELF WITH HANG FOR EACH F.02A MODULE AND (1) EXTRA INTERMEDIATE SHELF FOR EACH F.02B MODULE - IN ADDITION TO THE QUANTITY SHOWN ON THE DRAWINGS.
F.02B - PLAN AT CUBBY
DRAWN BY: Author
WALL MOUNTED BUNK (F.02A, F.02B, & F.02C)
A-407 SHEET 8 OF 21
ARCHITECT OF RECORD:
PARTITION AS SCHEDULED BY G.C. 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
TOP SHELF HELD FIXED IN PLACE BY SET SCREW AND ANGLE AT BACK BY F.C.; FINISH TO MATCH MT-01
1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01
3/8"
1"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02 1' - 8 3/4" TOP SHELF
1 1/2"
1 1/2"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3"
1' - 8 3/4" 1 1/4"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3"
1 1/2"
1 1/2"
1/4"
TOP SHELF
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
2 1/4"
3/4" 1 7/8"
2"
1 1/4"
2 1/4"
3/4"
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
4" 1 1/4"
10"
1"
2"
11 3/8"
1/8"
1"
1/8"
3 1/4"
1/8"
1 1/2"
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
2 1/2"
1' - 4 3/4"
1 1/2"
3/8"
1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01
1' - 9 1/8"
1 1/2" 3/8"
1' - 9 1/8"
6
F.02 - SECTION DETAIL AT TOP SHELF - TYP. SCALE: 6" = 1'-0"
1"Ø METAL FACE-OUT HANG ROD SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01
4 3/8"
1' - 5"
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
PARTITION AS SCHEDULED BY G.C. 3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
3/8"
2018 STANDARD FIXTURE PACKAGE
3"
1/4"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3/8"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3"
TOP SHELF HELD FIXED IN PLACE BY SET SCREW AND ANGLE AT BACK BY F.C.; FINISH TO MATCH MT-01
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1"
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
1"Ø METAL TUBE TOP CAP; BRASS FINISH TO MATCH MT-01
PARTITION AS SCHEDULED BY G.C.
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
1' - 8 3/4"
10
1 1/2"
SHELF TYP.
F.02 - SECTION DETAIL AT TOP SHELF W/ HANG SCALE: 6" = 1'-0"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
PARTITION AS SCHEDULED BY G.C.
3/4"
1 1/2"
1' - 5"
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
1 1/2" 3/8"
1' - 9 1/8"
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3/8"
5
F.02 - SECTION DETAIL AT INTERMEDIATE SHELF - TYP.
STAMP HERE:
SCALE: 6" = 1'-0"
1' - 8 3/4"
1' - 9 1/8"
INTERMEDIATE SHELF
3/8" 3/4"
1 1/2"
1' - 5"
1 1/2"
4" 1 1/4"
10"
1"
2"
BOTTOM SHELF HELD FIXED IN PLACE BY SET SCREW AND ANGLE AT BACK; FINISH TO MATCH MT-01 1"
1' - 4 3/4"
1"
1/8"
3 1/4"
1/8"
2 1/2"
1 1/2"
4 3/8" 1' - 9 1/8"
3/8"
1' - 8 1/8"
1/2"
BOTTOM SHELF
1"Ø METAL FACE-OUT HANG ROD SECURED TO SHELF ABOVE; BRASS FINISH TO MATCH MT-01
3/4"
1 1/2"
1 1/2" x 2 1/4" CONTINUOUS 'L' ANGLE WELDED TO FRAME; BRASS FINISH TO MATCH MT-01
3 3/4"
WALL BASE AS SCHEDULED PARTITION AS SCHEDULED BY G.C.
1"
3/4" CONCEALED IN-WALL FRT PLYWOOD BLOCKING BY G.C.
9
F.02 - SECTION DETAIL AT INTERMEDIATE SHELF W/ HANG SCALE: 6" = 1'-0"
4
F.02 - SECTION DETAIL AT BOTTOM SHELF - TYP. SCALE: 6" = 1'-0"
DATE: 10/24/2018 DRAWN BY: Author CHECKED BY: Checker AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3"
1/4"Ø HANG ROD SUPPORTS FOR FACE-OUT LOCATIONS; SECURED TO SHELF ABOVE BRASS FINISH TO MATCH MT-01
PROJECT NO.: 218299
1 1/2"
1/8"
1 1/2"THK LACQUERED WOOD SHELF SECURED TO FRAME WITH 3/16"Ø PIN AND GROMMET; FINISH TO MATCH L-02
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
2 1/4"
11 3/8"
1 1/4"Ø x 1/8"THK HANG ROD END CAP; BRASS FINISH TO MATCH MT-01
7"
3/4"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
1 1/2" SQ. METAL TUBE FRAME; BRASS FINISH TO MATCH MT-01
3/16"Ø PIN AND GROMMET INSTALLED AT FRAME AND SHELF TO ALLOW SHELF ADJUSTABILITY, SPACE EVERY 1 1/2" O.C.
4"
2"
1 7/8"
3/4"Ø x 3/4"THK BRASS METAL OFFSTAND TO CONCEAL FRAME MOUNTING HARDWARE; FINISH TO MATCH MT-01
1"Ø METAL TUBE FOOT; BRASS FINISH TO MATCH MT-01
WALL MOUNTED BUNK (F.02A, F.02B, & F.02C)
A-408 SHEET 9 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
5 A-409
1/8"Ø x 7/8" STOP PIN BRASS FINISH TO MATCH MT-01
4' - 3" 1 1/2"
1/2" 1" 2 1/2"
2' - 11"
1"
1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01
10 1/2"
1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03 R
3"
1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01
10 "
1/8"Ø x 7/8" STOP PIN BRASS FINISH TO MATCH MT-01 1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-01 1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03
2018 STANDARD FIXTURE PACKAGE
5' - 9"
5' - 9"
5' - 2"
1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01
1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01
1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03 1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01
2
F.03 FREE STANDING RACK 1 - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
1' - 0 1/2"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
2 1/2"
1"
PROJECT NO.: 218299 DATE: 10/24/2018
1' - 0"
3' - 0"
2' - 2"
DRAWN BY: Author 1"
SCALE: 1 1/2" = 1'-0"
5"
80 °
F.03 FREE STANDING RACK 1 - SECTION
10 0°
CHECKED BY: Checker AREA: N/A #
3"
ISSUE ISSUE FOR BID
DATE 10/24/2018
1' - 0 1/2"
5
° 80
0° 10
4 1/2"
1"
1"
1/2"
1/8"Ø x 7/8" STOP PIN BRASS FINISH TO MATCH MT-01 1"Ø METAL TUBE; BRASS FINISH TO MATCH MT-01
1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01
1
F.03 FREE STANDING RACK 1 - PLAN SCALE: 1 1/2" = 1'-0"
1"Ø FACE-OUT HANG BAR WITH 1 1/4"Ø X 1/8" THK END CAPS ; BRASS FINISH TO MATCH MT-01 1" x 1" SQ METAL TUBE; FINISH TO MATCH MT-03
FREE STANDING RACK 1 (F.03)
A-409 SHEET 10 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
5 A-410
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01 1" 2"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
4' - 0" 3' - 4"
1" 2" 1"
2018 STANDARD FIXTURE PACKAGE
5' - 9"
5' - 5"
5' - 9"
5' - 9"
1" 1" 1"
1" 2" 1"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
9
F.04A - FREE STANDING RACK 2A - LIGHT GREEN SCALE:
LAQUERED WOOD SHELF AT BASE L-05 OR L-06 LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06
R5 "
R
5"
1"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
1"
6 1/2"
1"
6 1/2"
1' - 2"
5
F.04A - FREE STANDING RACK 2A - SECTION
2
SCALE: 1 1/2" = 1'-0"
F.04A - FREE STANDING RACK 2A - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
4' - 0" 4' - 0"
6" 1"
5"
6"
3' - 0" 1"
2' - 10"
6" 1"
5"
3' - 0" 1"
2' - 10"
6"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
1"
1"
PROJECT NO.: 218299 1"
7
SCALE:
4
F.04A - FREE STANDING RACK 2A - PLAN AT BASE SCALE: 1 1/2" = 1'-0"
#
ISSUE ISSUE FOR BID
DATE 10/24/2018
5 1/2"
1"
AREA: N/A
1"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06
F.04A FREE STANDING RACK 2A - GRAY
CHECKED BY: Checker
1' - 2"
4"
1' - 2"
1"
5 1/2"
4"
5 1/2" 1"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
DRAWN BY: Author
5 1/2"
1"
DATE: 10/24/2018
LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06
1
F.04A - FREE STANDING RACK 2A - PLAN AT TOP SCALE: 1 1/2" = 1'-0"
FREE STANDING RACK 2A (F.04A)
A-410 SHEET 11 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671 5 A-411
4' - 0" 1" 2" 1"
3' - 4"
1" 2" 1"
1"
3' - 10"
1"
1" 1" 1"
1" 2"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
2018 STANDARD FIXTURE PACKAGE
5' - 9"
5' - 9"
4' - 5"
4' - 9"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
LAQUERED WOOD SHELF; FINISH TO MATCH L-05 OR L-06
1"
SCALE:
6 1/2"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
LAQUERED WOOD SHELF; FINISH TO MATCH L-05 OR L-06
LAQUERED WOOD SHELF AT BASE L-05 OR L-06
R
R5 "
10"
LAQUERED WOOD SHELF AT BASE L-05 OR L-06
5"
1"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
1"
11"
1"
1"
6 1/2"
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
1" 1"
F.04B FREE STANDING RACK 2B - OPT 2
10"
9
1' - 2"
5
F.04B - FREE STANDING RACK 2B - SECTION
2
SCALE: 1 1/2" = 1'-0"
F.04B FREE STANDING RACK 2B - ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
4' - 0"
6"
1"
5"
3' - 0"
1"
2' - 10"
6"
1"
5"
4' - 0"
1"
4"
3' - 4"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
4"
PROJECT NO.: 218299 DATE: 10/24/2018
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
7
F.04B FREE STANDING RACK 2B - OPT 1 SCALE:
4
LAQUERED WOOD SHELF AT BASE; FINISH TO MATCH L-05 OR L-06
F.04B FREE STANDING RACK 2B - PLAN AT BASE SCALE: 1 1/2" = 1'-0"
6 1/2"
CHECKED BY: JSP
1' - 2"
AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
6 1/2"
1"
1' - 2"
6 1/2"
1"
6 1/2"
DRAWN BY: EM
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
1
LAQUERED WOOD SHELVES BELOW; FINISH TO MATCH L-05 OR L-06
F.04B FREE STANDING RACK 2B - PLAN AT TOP SCALE: 1 1/2" = 1'-0"
FREE STANDING RACK 2B (F.04B)
A-411 SHEET 12 OF 21
ARCHITECT OF RECORD:
8 A-412 15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1"
1/2"
1/2"
1/4" 1/8" Ø x 1/2" STOP PINS ON BOTH SIDES; BRASS FINISH TO MATCH MT-01
5' - 2" 1"
1"
EQ
1/8" Ø x 1/2" STOP PINS ON BOTH SIDES; BRASS FINISH TO MATCH MT-01
1 x 1 SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
R
99 /32 "
EQ
5' - 0"
1/2"
1"
1' - 6 5/8"
3/4"
11 1/8"
EDGE OF DISPLAY PLATFORM BY G.C.
HOLD
2 1/2"
2' - 6 3/4" A.F.F. WINDOW SILL
PIPING CLEARANCE WHERE APPLICABLE; REF. PLANS AND ELEVATIONS FOR EXACT LOCATIONS
2018 STANDARD FIXTURE PACKAGE
3/4"
7' - 5"
7' - 5"
5' - 0"
5' - 0"
1 x 1 SQ METAL TUBES; BRASS FINISH TO MATCH MT-01
PIPING CLEARANCE WHERE APPLICABLE; REF. PLANS AND ELEVATIONS FOR EXACT LOCATIONS
1' - 9 7/8" SIAMESE CLEARANCE
SIAMESE CLEARANCE
2' - 1 3/4"
2' - 5"
DISPLAY PLATFORM BY G.C.
DISPLAY PLATFORM
SIAMESE CLEARANCE
10 A-412
2' - 1 3/4"
DISPLAY PLATFORM
2' - 5"
2' - 5" A.F.F. T.O. PLATFORM
SALES SIDE
0' - 0" A.F.F. FINISHED FLOOR
0' - 0" A.F.F. FINISHED FLOOR
1' - 1" SIAMESE CLEARANCE
8
STANDING RACK SECTION
1
SCALE: 1 1/2" = 1'-0"
NOTE: MOUNTING PLATES MUST BE FABRICATED AND SENT TO JOBSITE EARLY
STANDING RACK ELEVATION
STAMP HERE:
SCALE: 1 1/2" = 1'-0"
8 A-412
7 7/8"
EDGE OF DISPLAY PLATFORM BY G.C
PROJECT NO.: 218299 DATE: 10/24/2018 CHECKED BY: JSP AREA: N/A
CONCEALED MOUNTING PLATE
ISSUE ISSUE FOR BID
DATE 10/24/2018
6 1/4"
MOUNTING PLATE
3 1/4"
1' - 0"
7 3/8"
1' - 0 1/2"
5' - 2"
#
1' - 0"
2' - 8" 1' - 0"
3/4" 1/8"
1' - 0"
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
DRAWN BY: EM 1/2"
DISPLAY PLATFORM BY G.C. PLM-01
1 x 1 SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
4' - 0"
7 3/8"
3 1/4"
1 1/2" 3/4"
1"
1' - 0"
1' - 0"
CONCEALED MOUNTING PLATE BLOCKING BY G.C.
3/4"
EXISTING STOREFRONT GLAZING GL-01
1"
1/2" 1/2"
1' - 7 1/2"
COUNTERSUNK SET SCREWS; FINISH TO MATCH MT-01
STOREFRONT
1"
ACCESS PANEL BY G.C. FINISH TO MATCH PLM-01
1" x 1" SQ METAL TUBE; BRASS FINISH TO MATCH MT-01
1' - 0"
STANDING RACK (F.05)
1
SALES
10
STANDING RACK SECTION DETAIL, TYP. SCALE: 6" = 1'-0"
4
STANDING RACK PLAN, TYP. SCALE: 1 1/2" = 1'-0"
A-412
A-412 SHEET 13 OF 21
ARCHITECT OF RECORD:
A-415
1' - 6"
1' - 6"
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
4' - 0 3/4"
ADJUSTABLE
FIXED
BAY
BAY
BAY
BAY BAY
A-415
1' - 6"
3' - 11 3/8"
1' - 11 7/8"
2' - 0"
1' - 9 7/8"
3' - 9"
4
7' - 5 1/4"
3' - 3"
BAY
FIXED ADJUSTABLE FIXED
1' - 6" 3"
1' - 11 7/8"
1' - 6"
1' - 6" 3"
4' - 0 1/8"
1' - 6"
1' - 6" 3"
1' - 0"
ADJUSTABLE
7' - 3 3/4"
3' - 7 1/4"
5' - 0 1/4"
2' - 6 3/4"
7' - 3 3/4"
7' - 3 3/4"
2' - 6 3/4" 6"
5' - 4"
1' - 6" 1' - 6" 3"
5' - 9 3/4"
2' - 6 3/4"
5 3/4"
2
1' - 10 5/8"
A-415
9' - 5 1/2"
1' - 5 1/4"
7' - 5 1/4"
1
1
F.06 - OPTION C ELEVATION EAST
3
SCALE: 1/2" = 1'-0"
F.06 - OPTION C ELEVATION SOUTH
2' - 0"
SCALE: 1/2" = 1'-0"
1' - 9 7/8"
3' - 9"
1' - 10 5/8"
9' - 5 1/2"
2
SCALE: 1/2" = 1'-0"
5' - 9 3/4"
2' - 6 3/4"
5
F.06 - JUNGLE GYM OPTION C SCALE: 1/2" = 1'-0"
3"
1' - 6"
1' - 6"
5' - 4"
1' - 5 1/4" 1' - 6 3/4" 3"
1' - 11 7/8"
3' - 11 3/8"
1' - 6"
FIXED BAY
ADJUSTABLE BAY
ADJUSTABLE BAY
ADJUSTABLE BAY
FIXED BAY
7' - 5 1/4"
9' - 5 1/2"
F.06 - OPTION C ELEVATION NORTH
5 3/4"
1' - 6"
1' - 5 1/4" 1' - 6 3/4"
1' - 11 1/4"
2018 STANDARD FIXTURE PACKAGE
1' - 9 7/8"
7' - 3 3/4"
7' - 3 3/4"
2' - 6"
3' - 9"
3"
3' - 4 3/4" 1' - 6"
1' - 11 3/8"
2' - 6 3/4"
6 1/2"
1' - 6 3/4"
A-415
4' - 0 3/4"
2' - 5 1/4" 3"
1' - 6"
1' - 6"
7' - 3 3/4"
1' - 7 1/2"
3
4
F.06 - OPTION C ELEVATION WEST
GLASS PANEL
STAMP HERE:
SCALE: 1/2" = 1'-0"
REMOVABLE DRAWER
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: JSP CHECKED BY: JSP AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
JUNGLE GYM (F.06) OPTION C
A-415 SHEET 16 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
WOOD BLOCKING AS REQ'D
8
CENTER SCREEN IN TRANSITION WIDTH
A-417 12 A-417
BRASS TRANSITION BY G.C., CENTER SCREEN WITHIN TRANSITION
1/8"
1/8" 1" GL-06
GL-04
REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS
GL-06
CENTER SCREEN IN TRANSITION WIDTH 1"
1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH 1"
2' - 9 1/2"
MT-01
EDGE OF TRANSITION BEYOND
EDGE OF TRANSITION BEYOND 1/4"
3/8"
1' - 10 1/2"
1"
MONDRIAN SCREEN - CEILING CONNECTION DETAIL
GL-06
3"
SILICONE 1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01 RUBBER SETTING AND CENTERING BLOCK
1"
8' - 11 1/2"
1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01
GL-04
COUNTERSUNK SCREWS TO SECURE FINISH PLATE; FINISH TO MATCH MT-01
WINDOW FIXTURE
EDGE OF TRANSITION BEYOND
4"H x 1/8" THK METAL FINISH PLATE; FINISH TO MATCH MT-01
1"
2018 STANDARD FIXTURE PACKAGE
1 1/4"
REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS
4' - 4 1/2"
3"
4"H x 1"D x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01
1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01
3/8" 1/8"
1/4"
4' - 4 1/2"
3/8" 1/8"
1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01
8' - 6 3/8"
1 1/4"
GL-04
1"
SCALE: 6" = 1'-0"
8' - 11 1/2"
12
REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS
1' - 6 1/2"
5' - 4 1/2"
3/8"
1" 1' - 10 1/2"
2' - 9"
1"
3 1/8"
1"
1"
1"
3 1/8"
9' - 0" A.F.F. LOUNGE TRANSITION
3' - 0 7/8"
SILICONE 1" x 1" x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01
1/8" 1"
1/2"
1' - 6"
2' - 1 3/8"
RUBBER SETTING AND CENTERING BLOCK
1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01
1/8" THK METAL ANGLE; FINISH TO MATCH MT-01
2' - 1 3/8"
1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01
COUNTERSUNK SCREWS SPACED @ 16" O.C. MAX.; FINISH TO MATCH
BRASS TRANSITION BY G.C., CENTER SCREEN WITHIN TRANSITION
9' - 0" A.F.F. LOUNGE TRANSITION
1 1/8"
BRASS TRANSITION BY G.C. 1/2"
1"
COUNTERSUNK SCREWS SPACED @ 16" O.C. MAX.
1" x 1" STEEL CHANNEL; BRASS FINISH TO MATCH MT-01
GL-06
4"H x 1/8" THK METAL FINISH PLATE; FINISH TO MATCH MT-01 SHIM AS REQ'D
FINISHED FLOORING AS SCHEDULED
FRT WOOD BLOCKING
0' - 0" A.F.F. FINISHED FLOOR
4"
4"
0' - 0" A.F.F. FINISHED FLOOR
4"H x 1"D x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01 4"
NEW 5/8"THK WOOD FLOOR, GLUED TO SUBFLOOR
1" 11 A-417
WOOD BLOCKING AS REQ'D
4' - 4 1/2"
1"
EQ
3' - 4 1/2"
MT-01
0' - 0" A.F.F. FINISHED FLOOR 1"
8' - 0"
EQ
COUNTERSUNK SCREW
11
MONDRIAN SCREEN - FLOOR CONNECTION DETAIL SCALE: 6" = 1'-0"
8
MONDRIAN SCREEN-SECTION
5
SCALE: 1" = 1'-0"
MONDARIAN SCREEN- ELEVATION
STAMP HERE:
SCALE: 1" = 1'-0"
REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS
1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01
4"H x 1"D x 1/8" THK METAL ANGLE; FINISH TO MATCH MT-01
REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS
SILICONE
REFERENCE ELEVATIONS FOR GLAZING TYPE AND LOCATIONS
1"
1' - 6"
1"
3/4" 1/4"
1/4"
4"H x 1/8" THK METAL FINISH PLATE AT BASE BELOW ; FINISH TO MATCH MT-01
4"H x 1/8" THK METAL FINISH PLATE BELOW; FINISH TO MATCH MT-01
1" STEEL CHANNEL WITH NO VISIBLE SEAMS; BRASS FINISH TO MATCH MT-01
1' - 2"
1"
1' - 6 1/2"
10
SCALE: 6" = 1'-0"
7
MONDRIAN SCREEN - END CAP DETAIL SCALE: 6" = 1'-0"
4
MONDRIAN SCREEN - PLAN SCALE: 1" = 1'-0"
1"
3' - 4 1/2"
1"
DRAWN BY: RE, NK CHECKED BY: JSP AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
7 A-417
10 A-417
5 A-417
MONDRIAN SCREEN - VERTICAL CHANNEL DETAIL
1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01
8' - 0"
1"
1"
PROJECT NO.: 218299 DATE: 10/24/2018
1 1/4"
3/8" 1/8"
1"
1" x 1" STEEL "U" CHANNEL; BRASS FINISH TO MATCH MT-01
1/4"
1 1/4"
1"
1/4" 3/8" 1/8"
1 1/4"
3/8" 1/8"
3/8" 1/8"
RUBBER SETTING AND CENTERING BLOCK
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
8 A-417
MONDRIAN SCREEN (F.07)
A-417 SHEET 18 OF 21
ARCHITECT OF RECORD:
2018 STANDARD FIXTURE PACKAGE
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
STAMP HERE:
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: RE, GR CHECKED BY: JSP AREA: N/A #
ISSUE ISSUE FOR BID
DATE 10/24/2018
GLASS AND BRASS STAND (F.08)
A-418 SHEET 19 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
1
2
1
2
A-420
A-420
A-420
A-420
3' - 6" ADA BENCH CUSHION BY OWNER'S VENDOR 10 1/2"
HOLD
6"
1' - 1 1/2"
BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02
CUT-OUT FOR EASE OF INSTALL BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02
HOLD
BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02 HOLD
BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02
1' - 3"
BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02
HOLD 1' - 4 1/2"
1 1/2"
BOX IS SCREWED TO WALL; G.C TO PROVIDE INWALL BLOCKING; REF ELEVATIONS
MIN. TOE CLEARANCE 1 1/2"
BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02
1 1/2"
BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02
3' - 0"
1' - 3"
1'-9" CUTOUT
1 1/2"
10 1/2"
3' - 6"
HOLD 1' - 4 1/2"
HOLD
1' - 1 1/2"
ADA BENCH CUSHION BY OWNER'S VENDOR
BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH
1 1/2"
0' - 0" A.F.F. FINISHED FLOOR
2' - 10 1/2"
6"
2018 STANDARD FIXTURE PACKAGE
PT-02
LEG LEVELER AND T- NUT; TYP.
0' - 0" A.F.F. FINISHED FLOOR
3' - 0"
MIN.TOE CLEARANCE
4
ADA BENCH LONG SECTION
2
SCALE: 3" = 1'-0"
1
2
A-420
A-420
ADA BENCH SECTION THROUGH SETBACK SCALE: 3" = 1'-0"
1
2
A-420
A-420
3' - 6"
10 1/2"
1'-9" CUTOUT
BOX IS SCREWED TO WALL; G.C TO PROVIDE IN-WALL BLOCKING; REF ELEVATIONS
10 1/2"
HOLD 6"
3/4"
3 1/2"
3/4"
3' - 0"
MIN. TOE CLEARENCE
1 1/2"
ABOVE
BENCH SETBACK: (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02
STAMP HERE:
3' - 6"
HOLD
BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02
3/4"
3/4"
PROJECT NO.: 218299 DATE: 10/24/2018 DRAWN BY: RE HOLD
HOLD
1' - 8"
3/4"
HOLD
BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02
1' - 8"
3/4"
3/4"
MITER CORNER
CHECKED BY: JSP AREA: N/A
1 1/2"
#
MIN. TOE CLEARENCE
ADA BENCH PLAN SECTION SCALE: 3" = 1'-0"
3' - 0"
2 A-419
1
ADA BENCH PLAN SCALE: 3" = 1'-0"
MIN. TOE CLEARANCE
6"
1 1/2"
6"
A-419
2' - 9"
BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02
MIN. TOE CLEARANCE
2
1 1/2"
6"
BENCH TOP ABOVE; PAINT GRADE MDF; FINISH TO MATCH PT-02
3
3 1/2"
3/4"
1' - 2"
A-419
CUT-OUT ABOVE FOR EASE OF INSTALL LEG LEVELER AND T-NUT TYP.
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
4
HOLD
1' - 2"
11"
7" CUTOUT
A-419
ABOVE
4
ISSUE ISSUE FOR BID
DATE 10/24/2018
ADA FITTING ROOM BENCH (F.09)
A-419 SHEET 20 OF 21
ARCHITECT OF RECORD:
15 W 37TH ST 15TH FL NEW YORK, NY 10018 P: (212) 279-2670 F: (212) 279-2671
4
2
A-419
A-419
1' - 8" 1' - 2"
ADA BENCH CUSHION BY OWNER'S VENDOR
HOLD
6" MIN. TOE CLEARANCE
1 1/2"
1 1/2"
BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02
HOLD
HOLD 1' - 4 1/2"
BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02
1' - 3"
1' - 1 1/2"
BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02
BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02
2018 STANDARD FIXTURE PACKAGE
2
0' - 0" A.F.F. FINISHED FLOOR
ADA BENCH SHORT SECTION THROUGH SETBACK SCALE: 3" = 1'-0"
2 4
A-419
A-419
STAMP HERE:
1' - 8"
ADA BENCH CUSHION BY OWNER'S VENDOR
HOLD 3 1/2"
7" CUTOUT
9 1/2"
1 1/2"
BENCH TOP; (1) LAYER OF PAINT GRADE MDF; ATTACHED AFTER BENCH IS FIXED TO WALL; FINISH TO MATCH PT-02 1 1/2"
BENCH TOP EDGE; PAINT GRADE MDF MITERED TO FIT BENCH TOP; FINISH TO MATCH PT-02
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF ARCHITECT AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY WRITTEN AGREEMENT WITH ARCHITECT. DO NOT SCALE BLUEPRINTS.
BOX IS SCREWED TO WALL; G.C TO PROVIDE IN-WALL BLOCKING; REF ELEVATIONS
PROJECT NO.: 218299
HOLD
1' - 3"
1' - 1 1/2"
CUT-OUT FOR EASE OF INSTALL
HOLD 1' - 4 1/2"
BENCH TOP UNDERSIDE; (1) LAYER OF PAINT GRADE MDF; FINISH TO MATCH PT-02
DATE: 10/24/2018 DRAWN BY: Author CHECKED BY: Checker AREA: N/A #
BENCH SETBACK; (2) LAYERS OF PAINT GRADE MDF; FINISH TO MATCH PT-02
ISSUE ISSUE FOR BID
DATE 10/24/2018
0' - 0" A.F.F. FINISHED FLOOR
LEG LEVELER AND T-NUT TYP.
1 1/2"
11"
1' - 2"
1 1/2"
6"
ADA FITTING ROOM BENCH (F.09)
MIN. TOE CLEARANCE
3
ADA BENCH VIEW SCALE:
1
ADA BENCH SHORT SECTION SCALE: 3" = 1'-0"