RMG 720
Safety shut-off valve RMG 720 Safety Shut-off Valve (SSV), Direct-acting According to EN 14382 Application
Device for distribution stations as well as commercial and industrial facilities Compact design Easy to maintain due to exchangeable function units (cartridge assembly) Optionally with actuator systems: K 1a, K 2a (DN 25) or K 4, K 5, K 6 (≥ DN 50) Function Class A (B) Optionally with vent valve RMG 915 Suitable for non-aggressive gases, other gases on enquiry
Table face -to -face dimension and setting range Technical description
CE registration according to PED
RMG_720_00_DE_2007_07 RMG_720_00_EN_2007_07
Max. admissible pressure PS
= 25 bar
Max. operating pressure p
up to 25 bar
RMG_720_00_PL RMG_720_00_RU_2007_07
max
Max. admissible pressure PS
= 16 bar (DN 25)
Max. operating pressure p
up to 16 bar (DN 25)
Cut-away views RMG_720_721_s
Operation & maintenance, spare parts
max
Outlet pressure range
For over-pressure Wdso 40 mbar to 4.5 bar
RMG_720_20_DE_2002_10
For under-pressure Wdsu 5 mbar to 0.4 bar Connection
RMG_720_20_DE_2008_01
DIN flange PN 16, PN 25 and Flange Class 150 according to ANSI 16.5 in DN 25, DN 50, DN 80, DN 100
RMG_720_20_EN_1991_08 RMG_720_20_EN_2008_01 RMG_720_20_NL_2008_01
Response time t
0.1 s to 0.3 s
Additional features (as requested by customer)
Electromagnetic release (by current supply) Electric signal sensor for valve position “CLOSED” (proximity switch)
RMG_720_20_RU_1999_03 RMG_720_20_RU_2008_01
All mechanical components of this device are without potential ignition sources and / or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements. To top RMG Regel + Messtechnik GmbH | Osterholzstrasse 45 | D-34123 Kassel, Germany | Phone +49 (0)561 5007-0 | rmg@honeywell.com | Imprint / Legal Notice | Privacy Statement