Towel Rails Brochure

Page 1

Nu-Heat

UNDERFLOOR & RENEWABLES

towel rails

wa r m wat e r u n d e r f l o o r h e at i n g design

innovation

expertise

service

V8 11.11.09


towel rails To complement the Nu-Heat underfloor heating system and EnergyMaster™ cylinder package, Nu-Heat introduces its stunning new contemporary range of 100% stainless steel heated towel rails. Nu-Heat always recommends that heated towel rails are used in addition to warm water underfloor heating – they give the luxury of warm dry towels all year round and add extra warmth and comfort to bathrooms. Nu-Heat towel rails are manufactured in stainless steel as this has significant advantages over traditional chrome rails which cannot be used on a domestic water circuit. It will not rust or flake, is easy to clean and totally hygienic. All towel rails are produced from over 90% recycled, 304 grade metal, are manufactured environmentally and are themselves 100% recyclable. Small marks or scratches can be polished out to maintain high surface quality over many years. Each towel rail is manufactured with standard 1/2“ BSP tappings and is pressure tested to 12 Bar. We have such confidence in the high standard of manufacture that Nu-Heat towel rails are guaranteed for 25 years.

Towel rails can be installed directly off the boiler; alternatively, one of the most successful installation methods is to fit it directly onto an Aquastar™ hot water loop. Aquastar™ is a small bronze pump with built-in timer that circulates warm water from the cylinder under the domestic hot water draw off points. As soon as the tap is opened, instant domestic hot water is provided, no matter the distance from the cylinder. Towel rails are simply plumbed into this circuit meaning that they can work independently of the heating – particularly useful in the summer. In addition, towel rails on this circuit are at domestic hot water temperature rather than full boiler temperature preventing any risk of scalding. All models can, of course, be fitted directly onto a standard radiator circuit. Please refer to the Nu-Heat website for more details on both the EnergyMaster™ mains pressure hot water cylinder and Aquastar™ hot water loop.


Bathroom 1

planning and installing the loop

Bathroom 2

out For cylinder connection details refer to cylinder manufacturer

Outlet balancing valves

return

Radiator lockshield valves

Bathroom 3 Non-return valve (may be part of pump)

Pump

Kitchen

Utility Loop balancing valves

Flush/drain

Discharge

Expansion Vessel

benefits of nu-heat towel rails

guarantee

• Guaranteed for 25 years against manufacturing defects

A 25 year guarantee against manufacturing defects for all towel rails and radiators, proof of purchase is required for a replacement unit; guarantee does not extend to fitting costs and delivery charges.

• Stunning contemporary range of options to choose from • Made from 100% polished stainless steel • Made from over 90% recycled 304 grade metal • Easy to keep clean and highly polished • Warm, dry towels all year round • Can be installed on the Aquastar™ pumped domestic hot water loop

See the full range of towel rails at www.towelrails.co.uk or telephone 0800 731 1976.


www.towelrails.co.uk

flat fronted rails

Farway 400

Farway 520

Farway 620

Musbury 400

Musbury 520

Musbury 620

Farway 300 (Not illustrated) TRF300P-C 1250x300mm 2103btu/617watts

Musbury 300 (Not illustrated) TRM300P-C 700x300mm 1068btu/313watts

Farway 400 TRF400P-C 1250x400mm 2368btu/694watts

Musbury 400 TRM400P-C 700x400mm 1380btu/404watts

Farway 520 TRF520P-C 1250x520mm 2500btu/733watts

Musbury 520 TRM520P-C 700x520mm 1500btu/440watts

Farway 620 TRF620P-C 1250x620mm 2726btu/799watts

Musbury 620 TRM620P-C 700x620mm 1648btu/483watts


www.towelrails.co.uk

curved fronted rails

Uplyme 400

Uplyme 520

Uplyme 620

Kilmington 400

Kilmington 520

Kilmington 620

Uplyme 400 TRU400P-C 1250x400mm 2486btu/728watts

Kilmington 400 TRK400P-C 700x400mm 1449btu/425watts

Uplyme 520 TRU520P-C 1250x520mm 2600btu/762watts

Kilmington 520 TRK520P-C 700x520mm 1600btu/469watts

Uplyme 620 TRU620P-C 1250x620mm 2841btu/832watts

Kilmington 620 TRK620P-C 700x620mm 1763btu/517watts


www.towelrails.co.uk

flat fronted rails

Colyford

Bickleigh 1000

Cotleigh

Oakford

Dolton

Colyford TRC600P-C 1191x600mm 2859btu/838watts

Cotleigh TRCT500P-C 780x500mm 1998btu/585watts

Bickleigh 750 (Not illustrated) TRB750P-C 600x750mm 1676btu/491watts

Oakford TRO520P-C 700x520mm

740btu/217watts

Bickleigh 1000 TRB1000P-C 600x1000mm 1885btu/552watts

Dolton TRD520P-C 370x520mm

410btu/120watts


www.towelrails.co.uk

stainless steel feature radiators with towel hanger options

Woodbury with towel hanger

Woodbury

Salston with towel hanger

Salston

Woodbury 1460/360 TRW14/360P-C 1460x360mm 2406btu/705watts

Salston 1460/275 (3 panels) Satin finish TRS14/3S-C 1460x275mm 2154btu/631watts

Woodbury 1460/530 TRW14/530P-C 1460x530mm 2785btu/816watts

Salston 1460/360 (4 panels) Satin finish TRS14/4S-C 1460x360mm 2839btu/832watts

Woodbury 1460/710 TRW14/710P-C 1460x710mm 3498btu/1025watts

Salston 1460/535 (6 panels) Satin finish TRS14/6S-C 1460x535mm 3676btu/1077watts

Woodbury 1660/360 TRW16/360P-C 1660x360mm 2944btu/862watts

Salston 1960/275 (3 panels) Satin finish TRS19/3S-C 1960x275mm 2805btu/822watts

Woodbury 1660/530 TRW16/530P-C 1660x530mm 3408btu/998watts

Salston 1960/360 (4 panels) Satin finish TRS19/4S-C 1960x360mm 3715btu/1088watts

Towel hanger for Woodbury 360mm TRHW360P-C 530mm TRHW530P-C 710mm TRHW710P-C

Salston 1960/535 (6 panels) Satin finish TRS19/6S-C 1960x535mm 4210btu/1233watts Towel hanger for Salston Satin finish 3 panel TRHS3S-C 4 panel TRHS4S-C 6 panel TRHS6S-C


www.towelrails.co.uk

towel rail spec & dimensions

code

description

dimension labels

height

width

pipe centres

pipe centre from the wall

depth

mm

mm

mm

mm

mm

‘a’

‘b’

‘c’

‘d’

‘e’

TRB750P-C

Bickleigh 750

600

750

720

102

115

TRB1000P-C

Bickleigh 1000

600

1000

970

102

115

TRC600P-C

Colyford

1191

600

570

102

115

TRCT500P-C

Cotleigh

780

500

470

102

115

TRD520P-C

Dolton

370

520

490

102

115

TRF300P-C

Farway 300

1250

300

270

102

115

TRF400P-C

Farway 400

1250

400

370

102

115

TRF520P-C

Farway 520

1250

520

490

102

115

TRF620P-C

Farway 620

1250

620

590

102

115

TRK400P-C

Kilmington 400 (curved front)

700

400

370

102

140

TRK520P-C

Kilmington 520 (curved front)

700

520

490

102

165

TRK620P-C

Kilmington 620 (curved front)

700

620

590

102

165

TRM300P-C

Musbury 300

700

300

270

102

115

TRM400P-C

Musbury 400

700

400

370

102

115

TRM520P-C

Musbury 520

700

520

490

102

115

TRM620P-C

Musbury 620

700

620

590

102

115

TRO520P-C

Oakford

700

520

490

102

115

TRS14/3S-C

Salston 1460/275 - (3 panels) Satin Finish

1460

275

215

65

80

TRS14/4S-C

Salston 1460/360 - (4 panels) Satin Finish

1460

360

300

65

80

TRS14/6S-C

Salston 1460/535 - (6 panels) Satin Finish

1460

535

475

65

80

TRS19/3S-C

Salston 1960/275 - (3 panels) Satin Finish

1960

275

215

65

80

TRS19/4S-C

Salston 1960/360 - (4 panels) Satin Finish

1960

360

300

65

80

TRS19/6S-C

Salston 1960/535 - (6 panels) Satin Finish

1960

535

475

65

80

TRU400P-C

Uplyme 400 (curved front)

1250

400

370

102

140

TRU520P-C

Uplyme 520 (curved front)

1250

520

490

102

165

TRU620P-C

Uplyme 620 (curved front)

1250

620

590

102

165

TRW14/360P-C

Woodbury 1460/360

1460

360

300

55

75

TRW14/530P-C

Woodbury 1460/530

1460

530

470

55

75

TRW14/710P-C

Woodbury 1460/710

1460

710

650

55

75

TRW16/360P-C

Woodbury 1660/360

1660

360

300

55

75

TRW16/530P-C

Woodbury 1660/530

1660

530

470

55

75

* Heat output for installation directly from boiler – based on ΔT=60˚C (i.e. 80˚C flow temperature, 20˚C room temperature). ** Heat output for installation on Secondary Hot Water Loop – based on ΔT=35˚C (i.e. 55˚C flow temperature, 20˚C room temperature). Nu-Heat UK Ltd cannot be held liable for variation from these figures.


www.towelrails.co.uk

towel rail spec & dimensions

code

heat heat output fed output direct from shwl boiler* format**

description

btu

pipe centre from the wall

weight

watts btu watts centres from from top bottom

dimension labels

‘f’

‘g’

‘h’

kg

TRB750P-C

Bickleigh 750

1676

491

978

287

720

120

110

7.1

TRB1000P-C

Bickleigh 1000

1885

552

1100

322

970

120

110

8.6

TRC600P-C

Colyford

2859

838

1668

489

570

120

110

13.5

TRCT500P-C

Cotleigh

1998

585

1166

342

470

120

110

8.4

TRD520P-C

Dolton

410

120

239

70

490

120

110

2.66

TRF300P-C

Farway 300

2106

617

1229

360

270

120

110

7.5

TRF400P-C

Farway 400

2368

694

1381

405

370

120

110

8.3

TRF520P-C

Farway 520

2500

733

1458

428

490

120

110

9.38

TRF620P-C

Farway 620

2729

799

1592

467

590

120

110

10.88

TRK400P-C

Kilmington 400 (curved front)

1449

425

845

248

370

120

110

5.4

TRK520P-C

Kilmington 520 (curved front)

1600

469

933

274

490

120

110

6.72

TRK620P-C

Kilmington 620 (curved front)

1763

517

1028

302

590

120

110

7.8

TRM300P-C

Musbury 300

1068

313

623

183

270

120

110

4.8

TRM400P-C

Musbury 400

1380

404

805

236

370

120

110

5.2

TRM520P-C

Musbury 520

1500

440

875

257

490

120

110

5.6

TRM620P-C

Musbury 620

1648

483

961

282

590

120

110

6.66

TRO520P-C

Oakford

740

217

432

127

490

120

110

3.9

TRS14/3S-C

Salston 1460/275 - (3 panels) Satin Finish

2154

631

1257

368

175

85

0

13.1

TRS14/4S-C

Salston 1460/360 - (4 panels) Satin Finish

2839

832

1656

486

260

85

0

17.6

TRS14/6S-C

Salston 1460/535 - (6 panels) Satin Finish

3676

1077 2144

629

435

85

0

25.8

TRS19/3S-C

Salston 1960/275 - (3 panels) Satin Finish

2805

822

1636

480

175

85

0

17.5

TRS19/4S-C

Salston 1960/360 - (4 panels) Satin Finish

3715

1088 2167

636

260

85

0

21.5

TRS19/6S-C

Salston 1960/535 - (6 panels) Satin Finish

4210

1234 2456

720

435

80

0

34

TRU400P-C

Uplyme 400 (curved front)

2486

728

1450

425

370

120

110

8.5

TRU520P-C

Uplyme 520 (curved front)

2600

762

1517

445

490

120

110

9.76

TRU620P-C

Uplyme 620 (curved front)

2841

832

1657

486

590

120

110

11.8

TRW14/360P-C

Woodbury 1460/360

2406

705

1404

412

Variable

12.2

TRW14/530P-C

Woodbury 1460/530

2785

816

1625

476

Variable

18

TRW14/710P-C

Woodbury 1460/710

3498

1025 2041

598

Variable

24

TRW16/360P-C

Woodbury 1660/360

2944

863

1717

504

Variable

13.5

TRW16/530P-C

Woodbury 1660/530

3408

999

1988

583

Variable

20.3

* Heat output for installation directly from boiler – based on ΔT=60˚C (i.e. 80˚C flow temperature, 20˚C room temperature). ** Heat output for installation on Secondary Hot Water Loop – based on ΔT=35˚C (i.e. 55˚C flow temperature, 20˚C room temperature). Nu-Heat UK Ltd cannot be held liable for variation from these figures.


www.towelrails.co.uk

towel rail dimensions

Bickleigh, Colyford, Cotleigh, Dolton, Farway, Kilmington, Musbury, Oakford, Uplyme.

Salston, Woodbury.

G +

+

A

fixing points

+

A

+

H

C=F

C

B

B

Nu-Heat advises that bracket positions are taken from the towel rail once it arrives on site.

For pipe positions please see valve dimensions in conjunction with this information.

For pipe positions please see valve dimensions in conjunction with this information.

D

D

E

E


www.towelrails.co.uk

towel rail valve dimensions

Towel rail valve dimensions – Pipe position will be dimension’X’ below the towel rail. (Within +- 5mm).

Standard straight valves

Standard angled valves

TRSVP-C, TRSVS-C

TRAVP-C, TRAVS-C

X = 56

X = 42

17

Angled valves TRPVP-C

X = 42

17

Thermostatic valves straight

Thermostatic valves angled

TRTRVS-C

TRTRVA-C

X = 49

X = 76

21


www.towelrails.co.uk

accessories Valves for use when plumbed on a Secondary Hot Water Loop

Standard Straight Lockshield Valves (Polished) Pipes from floor. TRSLP-C

Standard Angled Lockshield Valves (Polished) Pipes from wall. TRALP-C

Salston Straight Lockshield Valves (Brushed) Pipes from floor. TRSLS-C

Salston Angled Lockshield Valves (Brushed) Pipes from wall. TRALS-C

Valves for use when plumbed directly from boiler

Standard Straight Valves (Polished) Pipes from floor. TRSVP-C

Standard Angled Valves (Polished) Pipes from wall. TRAVP-C

Salston Straight Valves (Brushed) Pipes from floor. TRSVS-C

Salston Angled Valves (Brushed) Pipes from wall. TRAVS-C

Angled Valves (Polished) Pipes from wall. Do not protrude outside dimensions of the towel rail. TRPVP-C

Nu-Heat

UNDERFLOOR & RENEWABLES

Heathpark House, Devonshire Road, Honiton, Devon ex14 1sd Tel: 01404 549770 Fax: 01404 549771 Web: www.nu-heat.co.uk Email: info@nu-heat.co.uk

• Delivery normally 3 working days from placing order. • Delivery included (UK mainland only).


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.