Construction Documents Sample

Page 1


GeneralManager

BUILDING

ARCHITECT

ARCHITECTURE

BrownHarrisStevens AndrewLasala PropertyManager alasala@bhsusa.com (212)508-7280 770LexingtonAvenue,NewYork,NY100655th floor

FifteenCentralParkWest Condominium GreggCarlovich GeneralManager gcarlovich@15cpw.com (212)246-0384 15CentralParkWestNewYorkNY10023

EthelindCoblinArchitect

ArchetypeArchitecture

ArchetypeArchitecture

INTERIORDESIGN

CONTRACTOR FongConstructionCorp.

EricCohen Principal/Architect ecohen@eca.nyc (212)967-2490 505EigtthAvenue,Suite2202,NewYork,NY10018

AlanBerman,Architect A.O.R. Aberman@archetype-ny.com (212)580-6087 101 2162Broadway,NewYork,NY10024

OmarKhalifa ProjectManager Okhalifa@archetype-ny.com (212)580-6087 120 2162Broadway,NewYork,NY10024

LaraSteiner ProjectManager Lsteiner@archetype-ny.com (212)580-6087 104

ColleenSlaterry InteriorDesigner CSlattery@archetype-ny.com (212)580-6087 121 2162Broadway,NewYork,NY10024

AlbaAlvarez InteriorDesigner aalvarez@archetype-ny.com (212)580-6087 119 2162Broadway,NewYork,NY10024

LiLiHuang President fong4736@hotmail.com (718)729-4736 40-2422ndStreet5thFloor,LongIslandCity,NY 11101

MFPENGINEERS CES MichaelRaffo ProjectManager mraffo@ceseng.com (845)656-8889

CarterWatson MechanicalEng. cwatson@ceseng.com (646)961-3999

GENERALBUILDINGNOTES:

A.PRIORTOANYDEMOLITIONWORK,ADUSTCONTAINMENTVESTIBULEANDNEGATIVEAIRPRESSUREMACHINESSHALLBEUTILIZEDPER MANUFACTURER'SGUIDELINESANDASDIRECTEDBYBUILDINGMANAGEMENTANDBUILDINGENVIRONMENTALGUIDELINES.DUST CONTAINMENTISOFTHEUTMOSTIMPORTANCE,ALLOPENINGSINFLOORS,WALLSANDCEILINGSTHATCOULDLEADTODUSTESCAPING TOOTHERAPARTMENTSORBUILDINGSPACESMUSTBESEALED.NEGATIVEAIRPRESSUREMACHINESREDUCEDUSTINFILTRATIONTO ADJACENTUNITSANDPUBLICSPACESOUTSIDEOFTHEUNITBEINGALTERED,PARTICULATEDUSTWITHINTHEWORKAREA,CLEANUPAND MAINTENANCETIME,ANDUNPLEASANTODORS.

B.ALLWORKISTOBEINCOMPLIANCEWITHALLSECTIONSOFTHEALTERATIONAGREEMENTANDTHEHOUSERULES.

C.PRIORTOTHEAPPROVALFORDEMOLITIONANDCONSTRUCTION,PROVIDEREQUIREDSECURITYDEPOSITASPERTHEALTERATION AGREEMENT.

D.POWER-ACTUATEDDEVICESMAYNOTBEUTILIZEDWITHOUTPRIORCONSENTFROMTHEBOARD,ASPERTHEALTERATIONAGREEMENT.

E.DEMOLITIONSHALLBEMANAGEDTOCOINCIDEWITHTHEAMOUNTOFDEBRISTHATCANBEPROPERLYREMOVEDONTHATDAY.THE CONTRACTORISTOPROVIDEFORPAINT,DEBRIS,DUST,ANDNOISECONTAINMENTASDIRECTEDBYTHERESIDENTMANAGER.ALLDEBRIS ISTOBEPROPERLYSEALEDINBAGSORCONTAINERSTHATWILLNOTPERMITDUSTTOLEAVETHEVESTIBULEORENTERTHEPUBLIC HALLS.NOTETHATREMOVALOFDEMOLISHEDMATERIALMUSTBECOORDINATEDWITHTHERESIDENTMANAGER.

F.WHERECHASES,SHAFTS,DEMISINGWALLSANDSTRUCTURALELEMENTSAREOPENEDDURINGCONSTRUCTION,PROVIDEAUL-LISTED FIRESTOPPINGORFIREPROOFINGSYSTEMASREQUIREDBYCODEATALLEXISTINGORNEWOPENINGS.WHEREPIPECHASESARE ENCLOSEDINMASONRYCONSTRUCTION,THEFIRERATINGMUSTBEMAINTAINEDANDWALLSTHATAREDEMOLISHEDINTHECOURSEOF THEWORKMUSTBERESTOREDWITHSIMILARCONSTRUCTIONORNEWCONSTRUCTIONWITHTHESAMERATING.WHEREPIPINGISNOT LOCATEDINARATEDENCLOSUREPROVIDEFIRESTOPPINGSYSTEMSASMANUFACTUREDBYSTI,HILTI,USGOREQUALULLISTED PRODUCTSAREACCEPTABLEANDTHEIRRATINGMUSTCOINCIDEWITHTHEFIRERATINGOFTHEEXISTINGASSEMBLY.ORDINARYCEMENT, INSULATIONANDOTHERNON-RATEDSEALANTSANDPRODUCTSMAYNOTBEUSEDUNLESSPARTITIONSPROVIDETHEREQUIREDFIRE RATING.NOTETHATFIRESTOPPINGANDFIREPROOFINGMUSTBEINSTALLEDUPONTHECOMPLETIONOFDEMOLITIONANDPRIORTOTHE INSTALLATIONOFANYSHEATHINGOROTHERWORKTHATWILLBLOCKACCESSTOANYOPENINGSTHATMUSTBEFIRESTOPPED.

G.THECONTRACTORISTOPROVIDEPROTECTIONASPERTHEMANAGER'SREQUIREMENTS.ALLTOILETANDKITCHENEXHAUSTSARETOBE COVEREDDURINGWORKINTHEAREA,THEHALLWAYSPROTECTEDANDSTICKYMATSPROVIDEDEACHDAYATTHEELEVATORSANDAT THEFRONTDOOR.

H.THECONTRACTORWILLBERESPONSIBLEFORADHERENCETOTHENYCNOISECODEANDASSOCIATEDNYCDEPARTMENTOF ENVIRONMENTALPROTECTION(DEP)REGULATIONS(LL113/05ANDRCNY28-100)ANDALLOTHERBUILDINGREQUIREMENTSASREGARDS NOISEANDCONSTRUCTIONNOISEMITIGATION.SHOULDTHEDEPREQUIREANOISEMITIGATIONPLAN,THECONTRACTORSHALL IMMEDIATELYCOMPLY.

I.NOTETHAT5LB.ABCFIREEXTINGUISHERSANDSMOKEDETECTORSMUSTBEMAINTAINEDINWORKINGORDERDURINGCONSTRUCTION. J.ONEFUNCTIONINGSLOPSINKANDTOILETMUSTBEMAINTAINEDINGOODWORKINGORDERATTHEJOBSITEFORTHECONSTRUCTION WORKERS.WORKERSWILLNOTBEALLOWEDTOUSETHEBUILDING'SFACILITIES.CAREMUSTBETAKENTOPREVENTRUNNINGWATER FROMOVERFLOWINGONTHEJOBSITE.

K.THERELOCATIONOFBUILDINGRISERS,INCLUDINGPLUMBINGANDELECTRICALWILLNOTBEPERMITTED.

L.CUTTINGINDEMISINGOREXTERIORWALLSFORPLUMBING,ELECTRICALORANYOTHERSERVICESWILLNOTBEALLOWED.THEWALLIS TOBEFURRED-OUTTOACCOMMODATETHENEWELECTRICALWORK,ETC.THERESIDENTMANAGERISTOINSPECTTHISWORKTO MONITORQUALITYCONTROL.

M.PROVIDEAND/ORMAINTAINFIRERATEDCONSTRUCTIONASREQUIREDATSHAFTS,STRUCTURALMEMBERS,ETC.

N.ALLNEWWALLFRAMINGMUSTBEMETALSTUDCONSTRUCTION.ALLWOOD,INCLUDINGPLYWOOD,USEDFORBLOCKINGOROTHER

SUPPORTISTOBEFIRE-TREATED,ANDTHETREATMENTMETHODMUSTBECOMPOSEDOFNON-TOXICMATERIALS.PROVIDEADETAILOF THEWALLCONSTRUCTION.

O.ALLWALLSMUSTBECOMPLETELYSHEATHEDANDALLOPENINGSINBLOCKWALLSMUSTBEPATCHEDORPLASTEREDPRIORTO INSTALLATIONOFCABINETRY.

P.THEARCHITECTISRESPONSIBLEFORMAINTAININGALLADAREQUIREMENTS.WHEREWALLSAREREPLACEDATALLBATHROOMS, INCLUDINGFORREPLACEMENTOFBRANCHPIPINGTOTHERISER,PLATESFORTHELOCATIONOFFUTUREGRABBARSARETOBE INSTALLEDASPERADAREQUIREMENTS.

Q.NEWYORKALONGWITH5OTHERNORTHEASTERNSTATES,INCLUDINGNEWJERSEYHASADOPTEDOTC(OZONETRANSPORT COMMISSION)GUIDELINESCONCERNINGVOC(VOLATILEORGANICCOMPOUND)REQUIREMENTS.THEREARESTRINGENTREQUIREMENTS CONCERNINGTHEUSEOFOILBASEDMATERIALS.ITWOULDBEBESTBOTHINTERMSOFQUALITYFINISHANDENVIRONMENTALISSUESTO SPRAYANYLACQUEROFFSITEINANAPPROPRIATEBOOTH.IFTHISISTOBESPRAYEDONSITE,CONTRACTORSARETOBELIMITEDTO PURCHASINGQUARTCANSONLY.THECONTRACTORSHOULDBEUSINGAHIGHVOLUME,LOWPRESSURESPRAYDEVICE. R.ANYCHANGESTOTHESCOPEOFWORKMUSTBESUBMITTEDFOROURREVIEWANDAPPROVALPRIORTOTHECOMMENCEMENTOFTHAT WORK.ALLFUTURESUBMITTEDDRAWINGSSHOULDHAVECHANGESBUBBLED.WEWILLONLYREVIEWBUBBLEDCHANGES. CONSEQUENCESFORANYNON-BUBBLEDCHANGESWILLBETHERESPONSIBILITYOFTHEUNITOWNER.

S.THEBUILDINGREQUIRESTHATTHEPUBLICHALLWAYS,SERVICEENTRYAREAS,SERVICEELEVATORLOBBIESANDADJACENTSTAIRWELLS BERETURNEDTOORIGINALCONDITIONUPONCOMPLETIONOFTHEALTERATION.ALLDAMAGESARETOBEREVIEWEDBYTHEGCWITH THEBUILDINGCONSULTINGARCHITECTRESIDENTMANAGERAND/ORBUILDINGMANAGEMENTPRIORTOCLOSEOUTTOCONFIRMSCOPE OFDAMAGEANDMETHODSOFREMEDIATION.THEBUILDINGRESERVESTHERIGHTTOHAVEANYREMEDIATIONWORKPERFORMEDBY VENDORSOFCHOICE.THECOSTOFSUCHWORKWILLBECHARGEDBACKTOTHEUNITOWNER.

T.WITHREGARDTOWALKTHROUGHS,THEUNITOWNER,ARCHITECTORCONTRACTORISTOINFORMTHERESIDENTMANAGER/BUILDING ARCHITECTONTHEFOLLOWINGMILESTONESSOTHATOBSERVATIONVISITSOFTHEWORKMAYBESCHEDULED:

T.1.PREPARATIONOFDIRTANDDUSTCONTROLPROCEDURES.

T.2.COMPLETIONOFDEMOLITIONANDFIRESTOPPINGANDFIREPROOFINGIFREQUIRED.

T.3.COMPLETIONOFELECTRICALANDPLUMBINGROUGHIN

T.4.COMPLETIONOFSOUNDPROOFINGANDWATERPROOFING

T.5.COMPLETIONOFMECHANICALEQUIPMENTINSTALLATION

T.6.COMPLETIONOFPROJECTPRIORTODOBANDELECTRICALSIGN-OFF

U.THEFOLLOWINGARETOBESUBMITTEDFORPROJECTCLOSE-OUT:

U.1.ALLITEMSARETOBEADDRESSEDFROMPASTFIELDREPORTS,ASNOTED.

U.2.THEGCISTOVERIFYTHATALLPUBLICAREASHAVEBEENRESTORED.

U.3.PROVIDECOPIESOFCLOSEOUTANDAPPROVALFROMTHEDOB,ELECTRICALDIVISIONANDPLUMBINGDEPT.

U.4.PROVIDECOPIESOFSIGNEDAIAFORMSG706,CONTRACTOR'SAFFIDAVITOFPAYMENTOFDEBTSANDCLAIMS,ANDG706A, CONTRACTOR'SRELEASEOFLIENSARETOBESUBMITTEDUPONSUBSTANTIALCOMPLETION.

U.5.PROVIDEAN8.5X11SKETCHOFTHEALTERATIONINDICATINGLOCATIONSOFALLVALVESANDTHELOCATIONOFACCESSPANELS WHEREAPPLICABLE.

PLOTPLAN-NOTTOSCALE

X 9 EN-101.00 POWERPLAN X 10 P-100.00 PLUMBINGPLAN X 11 P-101.00 PLUMBINGDETAILS X 12 P-102.00 PLUMBINGDETAILS X 13 A-301.00

X

PRIMARYBATHROOM(HERS)ELEVATIONS X

A-303.00 BATHROOM#1(HIS)ELEVATIONS X 16 A-304.00 BATHROOM#2(GUEST)ELEVATIONS X 17 A-305.00 BATHROOM#3(POWDER)ELEVATIONS X 18 A-306-A.00 PRIMARYBEDROOMELEVATIONS X 19 A-306-B.00 PRIMARYBEDROOM&FIREPLACEELEVATIONS X

A-307.00 GUESTBEDROOMELEVATIONS X

A-308.00

A-309.00 LIVINGROOMELEVATIONS X

X

A-310.00 LIVING/DININGCLOSETELEVATIONS X 24 A-311-A.00 FEMALECLOSETELEVATIONS X 25 A-311-B.00 FEMALECLOSETELEVATIONS X 26 A-312.00 MALECLOSETELEVATIONS X 27 A-313-A.00 HALLWAYELEVATIONS X 28 A-313-B.00 HALLWAYELEVATIONS X 29 A-401.00 GENERALAPARTMENTDETAILS&SCHEDULES X 30 A-402.00 DOORSCHEDULE&DETAILS X 31 A-403.00 DOORDETAILS X 32 A-404.00 KITCHENBANQUETTEMILLWORKDETAILS X 33 A-405.00 DININGROOMBANQUETTEMILLWORKDETAILS X 34 A-406.00 BATHROOMVANITYMILLWORKDETAILS. X

AREAOFWORK 15CENTRALPARKWEST NEWYOK,NY APT.36D(28THFLOOR)

INSPECTIONS

CONTROLLEDINSPECTIONSREQUIREDFOR: PROGRESSINSPECTIONS: FINALINSPECTION(DIRECTIVE14) ENERGYCODECOMPLIANCE FIRERESISTANTPENETRATIONSANDJOINTS

ENERGYCODEINSPECTION: LIGHTINGINDWELLINGUNITS. LIGHTINGCONTROLS.

PROJECTFILEDUNDERNYC2022BUILDINGCODE JOBDESCRIPTION:

ARCHITECTURALWORKFOR INTERIORAPARTMENT RENOVATIONS. PLUMBINGWORKFILEDUNDERA SEPARATEAPPLICATIONAS PLUMBINGWORKTYPE.

PROJECTINFORMATION:

15CENTRALPARKWESTNEWYORK,NY10023. EXISTINGHEIGHTSANDSETBACKSTOREMAIN.NOADDITIONAL BUILDINGAREAWILLBECONSTRUCTED.

BOROUGH: MANHATTAN(BOROUGH1) BLOCK: 1114 LOT: 7503

MAPNO: 8C

ZONING: C4-7

SPECIALDISTRICT: L

COMMERCIALOVERLAY: YES

BUILDINGCLASS: RM(CONDOMINIUM-MIXED RESIDENTIALANDCOMMERCIAL)

OCCUPANCYCLASS: J-2

CONSTRUCTIONCLASS: 1-B-3HRPROTECTED(NON-COMBUST)

MLTDWELLINGCLASS: CLASSA-HAEA HEIGHT: 489FEET

NO.OFBUILDINGS: 2 STORIES: 36

DWELLINGUNITS: 224

CONDO.NUMBER: 1653

NOCHANGEINUSE,EGRESSOROCCUPANCY

PROPERTYISNOTONS.F.H.A. (SPECIALFLOODHAZARDAREA)

ANSIDIAGRAMS:

1107.2.3.4COOKTOPSANDOVENS: COOKTOPSANDOVENSSHALLCOMPLYWITHSECTIONS1003.12.5.4AND1003.12.5.5OFICC A117.1,RESPECTIVELY.HOWEVER,OVENCONTROLSSHALLNOTBEREQUIREDTOBE LOCATEDONEITHERSIDEOFTHEOVENDOOR,PROVIDEDSUCHCONTROLSCOMPLYWITH SECTION1003.12.5.5.4OFICCA117.1.WHEREDOUBLEOVENSAREPROVIDED,ATLEASTONE OVENINTERIORANDITSCONTROLSSHALLCOMPLYWITHSECTION309.3(HEIGHT)OFICC A117.1.

1107.2.3.5KITCHENANDKITCHENETTESTORAGE: KITCHENSTORAGE,KITCHENCABINETS,DRAWERS,ANDSHELFSTORAGEAREAS,WITHIN KITCHENANDKITCHENETTESTHATAREREQUIREDTOCOMPLYWITHSECTION1003.12OFICC A117.1PURSUANTTOSECTION1107.2.3,EXCEPTOVERHEADCABINETS,SHALLCOMPLY WITHSECTION905(STORAGEFACILITIES)OFICCA117.1.INADDITION,ATLEASTONE STORAGESHELFORCABINET,MOUNTEDABOVEWORKCOUNTERSAT48INCHES(1219MM) MAXIMUMABOVE

EXCEPTION:WHERETHESTORAGESHELFORCABINETISNOTPROVIDEDINACCORDANCE WITHTHISSECTION,THEOWNERSHALLINSTALLSUCHSTORAGESHELFORCABINETIN COMPLIANCEWITHTHISSECTIONATTHETIMEAPERSONWITHPHYSICALDISABILITIES TAKESOCCUPANCYOFTHEUNIT,ORWITHIN10DAYSOFTHEDATETHEREQUESTISMADE BYAPERSONWITHPHYSICALDISABILITIES,WHICHEVERISLATER,ATTHEOWNER'S EXPENSE.

1004.12KITCHENSANDKITCHENETTES: KITCHENSANDKITCHENETTESSHALLCOMPLYWITHSECTION1004.12.1004.12.1 CLEARANCE.CLEARANCECOMPLYINGWITHSECTION1004.12.1SHALLBEPROVIDED. 1004.12.1.1MINIMUMCLEARANCE: CLEARANCEBETWEENALLOPPOSINGBASECABINETS,COUNTERTOPS,APPLIANCES,OR WALLSWITHINKITCHENWORKAREASSHALLBE40INCHES(1015MM)MINIMUM. 1004.12.1.2U-SHAPEDKITCHENS.INKITCHENSWITHCOUNTERS,APPLIANCES,ORCABINETS ONTHREECONTIGUOUSSIDES,CLEARANCEBETWEENALLOPPOSINGBASECABINETS, COUNTERTOPS,APPLIANCES,ORWALLSWITHINKITCHENWORKAREASSHALLBE60INCHES (1525MM)MINIMUM.

1004.12.2CLEARFLOORSPACE: CLEARFLOORSPACEATAPPLIANCESSHALLCOMPLYWITHSECTIONS1004.12.2AND305.3. 1004.12.2.1SINK.ACLEARFLOORSPACE,POSITIONEDFORAPARALLELAPPROACHTOTHE SINK,SHALLBEPROVIDED.THECLEARFLOORSPACESHALLBECENTEREDONTHESINK BOWL.EXCEPTION:ASINKWITHAFORWARDAPPROACHCOMPLYINGWITHSECTION 1003.12.4.1.

1004.12.2.2DISHWASHER: CLEARFLOORSPACE,POSITIONEDFORAPARALLELORFORWARDAPPROACHTOTHE DISHWASHER,SHALLBEPROVIDED.THEDISHWASHERDOORINTHEOPENPOSITIONSHALL NOTOBSTRUCTTHECLEARFLOORSPACEFORTHEDISHWASHER

PARTITIONTYPES:

ACCESSIBILITYNOTES:2014BCARTICLE11ACCESSIBILITY.ANSIA117.12009.

1107.2.2TYPEB+NYCUNITTOILETANDBATHINGROOMS WHERETOILETANDBATHINGROOMSAREPROVIDEDINTHETYPEB+NYCDWELLING UNITORSLEEPINGUNIT,ALLSUCHTOILETANDBATHINGROOMSSHALLCOMPLYWITH APPENDIXP.

EXCEPTIONFORTYPEATOILETANDBATHINGROOM: 1.0WHEREATLEASTONETOILETANDBATHINGROOMINTHETYPEB+NYC DWELLINGUNITORSLEEPINGUNITISCONSTRUCTEDINACCORDANCEWITHTHE TYPEATOILETANDBATHING FACILITIES REQUIREMENTSOFSECTION1003.11 (TOILETAND BATHINGFACILITIES),INCLUDINGSECTION1003.3.2(TURNING SPACE),OFICCA117.1ANDISINCOMPLIANCEWITHTHEFOLLOWING:

1.1ATLEASTONELAVATORY,ONEWATERCLOSETANDEITHERABATHTUBOR SHOWERWITHINSUCHTOILETORBATHINGFACILITYSHALLCOMPLY WITH  SECTION1003.11OFICCA117.1.SUCHTOILETANDBATHINGFIXTURES  SHALLBEINASINGLETOILETORBATHINGAREA,SUCHTHATTRAVEL BETWEENFIXTURESDOESNOTREQUIRETRAVELBEYONDTHEAREAINWHICH THEFIXTURESOFSUCHTOILETORBATHINGROOMARELOCATED.

1.2TOILETPAPERDISPENSERSWITHINSUCHROOMSSHALLCOMPLYWITH SECTION604.7(DISPENSERS)OFICCA117.1.

1.3MEDICINECABINETS,IFPROVIDED,MUSTINCLUDEASTORAGESHELFNO HIGHERTHAN44INCHES(1118MM)ABOVETHEFLOOR.

2.0WHEREATLEASTONETOILETANDBATHINGROOMCOMPLYINGWITHSECTIONS 1003.11AND1002.3.2OFICCA117.1ISPROVIDEDWITHINTHETYPEB+NYC DWELLINGUNITORSLEEPINGUNITINACCORDANCEWITHITEM1OFTHIS EXCEPTION,OTHERTOILETANDBATHINGROOMSINTHESAMEUNITSHALLBE REQUIREDTOCOMPLYONLYWITHSECTIONS 1004.3(ACCESSIBLEROUTE), 1004.4(WALKINGSURFACES),1004.5.2(USERPASSAGEDOORWAYS),1004.9 (OPERABLE PARTS)AND1004.11.1(GRABBARANDSHOWERSEAT REINFORCEMENT)OFICCA117.1.DOORSANDDOORWAYSTOSUCHTOILETAND BATHINGROOMSSHALLBESUBJECTTOSECTION1107.2.1,EXCEPTION5.

7/8"FURRINGCHANNEL@16"OC

UNDERSIDEOFSTRUCTUREABOVE. 5/8"GYPSUMBOARDCEILING-PRIMED&PAINTED

PARTITIONTYPE'B'

5/8"GYPSUMBOARD-PRIMED&PAINTED

EXISTING DEMISINGWALL TOREMAIN

5/8"GYPSUMBOARD-PRIMED&PAINTED 1-1/2"16GAUGEMETALSTUDS@16"O.C.

SOUNDATTENUATIONBATT INSULATIONBETWEENMETALSTUDS

BASEASSCHEDULED SEALANTATPERIMETER,TYP.

3-1/2"x16GAUGEMETALSTUDS@16"O.C.

5/8"GYPSUMBOARD @BOTHSIDES-PRIMED&PAINTED

SOUNDATTENUATIONBATTINSULATION BETWEENMETALSTUDS

ALLINTERIORPARTITIONS&FURRINGTOHAVEFULL HEIGHTSOUNDBATTS.QUIETROCKASNOTED.PARTITIONSCHEDULE:

NEWFULLHEIGHTPARTITIONPROVIDE316GAUGEMETALSTUDS@16"O.C.WITH ONELAYEROF5/8"TYPEXGYPSUMWALLBOARDONEACHSIDE,WITHSOUND ATTENUATIONBATTINSULATIONBETWEENSTUDSUPTOCEILING.

A1 NEWFULLHEIGHTPARTITIONFORWETAREAS: PROVIDE316GAUGEMETALWALLSTUDS@16"O.C.WITHONELAYERTYPE GYPSUMWALLBOARDONNON-WETSIDEWITHSOUNDATTENUATIONBATTINSULATION BETWEENSTUDSUPTOCEILINGANDONELAYEROFMOISTURERESISTANTCEMENT BOARDONWETSIDEFROMFLOORTOUNDERSIDEOFCEILINGABOVE.PROVIDEWOOD BLOCKINGTOSUPPORTCABINETRYANDBATHROOMACCESSORIES.

WASHINGMACHINEINSTALL

NOTE:WASHER/DRYERTOBE INSTALLEDINCOMPLIANCE WITH2014NYCBC

MADEWITHIN40DIAMETERSUPSTREAMOR10DIAMETERSDOWNSTREAMOFTHESUDSPRODUCINGFIXTURESDRAIN.90DEGREEBENDSARETOBE AVOIDEDWHEREPOSSIBLE,ANDPLUMBINGVENTSINSTALLEDAFTEREVERYTWO(2)90DEGREEBENDS.VENTSTOPREVENTSUDSPRESSURE-ZONE PROBLEMS.

SOFFITDETAIL:

SECTION

1-1/2"16GAUGEMETALSTUDS@16"O.C.

SOUNDATTENUATIONBATT INSULATIONBETWEENMETALSTUDS

BASEASSCHEDULED

1-1/2"x16GAUGEMETALSTUDS@16"O.C.

5/8"GYPSUMBOARD @BOTHSIDES-PRIMED&PAINTED

SOUNDATTENUATIONBATTINSULATION BETWEENMETALSTUDS

PLAN

B.INTERIORWALLFURRING

NEWFULLHEIGHTPARTITIONPROVIDE11 216GAUGEMETALSTUDS@16"O.C.WITH ONELAYEROF5/8"TYPEGYPSUMWALLBOARDONEACHSIDE,WITHSOUND ATTENUATIONBATTINSULATIONBETWEENSTUDSUPTOCEILING.

B NEWFURREDOUTWALL: 216GAUGEMETALWALLSTUDS@16"O.C.W/SOUNDATTENUATIONBATT INSULATIONUPTOCEILING.USE5/8"MOISTURERESISTANTGYPSUM/CEMENTBOARDON WETAREASANDCEMENTBOARDONLYFORALLBATHROOMAREAS

EXISTINGUNDERSLABPLASTERCEILING

FIRESTOPPINGDETAIL:

A.PACKALLSPACESFULLDEPTHW/MINERALWOOLOROTHEREQUALLYAPPROVEDFIRERESISTIVEMATERIAL(ASBESTOSORFIBERGLASS SHOULDNOTBEUSED).FIRERESISTANTFOAMSEALANTCHASEFOAMCTCP2-655MAYBEUSED.INSTALLATIONASPERMANUFACTURER.

B.ESCUTCHEONBOTHSIDES C.SLEEVE

D.INSULATION(OUTSIDEDIAMETER)

E.ANHYDROUSCALCIUMSILICATEINSULATIONTHRUSLEEVE

F.FIRERATEDPARTITION,WALLORFLOOR

G.FIBERGLASSINSULATION

H.TERMINATEINSULATIONATESCUTCHEON

I.MAXIMUM1/2"CLEARANCEBETWEENINSIDEOFSLEEVE&PIPE

DETAILOFPIPINGPIERCINGFIRERATEDPARTITIONS,WALLS&FLOORS

7.NOACCUMULATIONORDEBRISORREMOVED MATERIALS/EQUIPMENTWILLBEPERMITTED, CONTRACTORTOREMOVETHESEMATERIALS FROMSITEDAILY.

8.THEARCHITECTSHALLASCERTAINPRIORTO REMOVALTHATCOMPONENT/ITEMBEING REMOVEDISNONSTRUCTURAL.CONTRACTOR SHALLNOTIFYARCHITECT/STRUCTURALENGINEER OFANYDEVIATIONOFSTRUCTURALCONDITIONS FROMTHESESHOWNONTHEPLANS.

9.PRIORTOCOMMENCEMENTOFWORK,THE GENERALCONTRACTORTOFIELDVERIFY& IDENTIFYEXISTINGEQUIPMENTTOREMAININ SERVICETHATISSERVEDBYSYSTEMSTOBE REMOVED.REMOVEAND/ORRELOCATETHE SERVICESASDIRECTED.

10.ANYEXISTINGUTILITYSERVICESTOBEREMOVED, TERMINATED,ORDISCONNECTEDFORFUTURE RELOCATIONSHALLBECUT,CAPPED,SEALEDOR REMOVEDINACCORDANCEWITHAPPLICABLE CODESANDUTILITYCOMPANYREQUIREMENTS ANDRECOMMENDATIONS.

11.THEGENERALCONTRACTORWILLBE RESPONSIBLETOREMOVEALLABANDONED EQUIPMENTWITHINTHESPACE-CONFIRMWITH OWNERIFTOBEDISCARDEDORTOBEREUSED.

12.THEGENERALCONTRACTORSHALLBE

RESPONSIBLEFORMAINTAININGUSEOFALL UTILITIES,EXCEPTTHOSETOBEREMOVEDOR RELOCATEDFOREXTENTOFDEMOLITIONWORK. UTILITYINTERRUPTIONSMUSTBESCHEDULED WITHOWNERPRIORTOWORK.CONTRACTORIS RESPONSIBLEFORALLELECTRICREQUIREDTO HAVEPERMANENTORTEMPORARYPOWERTO THESITEDURINGCONSTRUCTION.

13.NOPLUMBINGWILLPROJECTINTOORBELOWTHE STRUCTURALSLABANDNOSTRUCTURALSLABS TOBECHANNELED.

14.NOBUILDINGVENTSTOBEDEMO,PROTECT DURINGDEMOLITION.

15.NOSTRUCTURALELEMENTSTOBEREMOVED. PROTECTANDINSULATEOPENINGSLEADINGTO STRUCTURALELEMENTS.SEEWALLDETAILSAND TOCOMPLYWITHBUILDINGCODEAND REGULATIONS.

16.CUTTINGORCHOPPINGOFFTHEEXISTING STRUCTURALCONCRETESLABFORPLUMBINGOR FORANYOTHERPURPOSEISNOTPERMITTED,SO ASNOTTOAFFECTTHESTRUCTURALINTEGRITY OFTHEBUILDING.

17.THECONTRACTORSHALLNOTDISRUPTANY EXISTINGGASRISERS,PLUMBINGRISERS,DATA/ INTERCOMCABLETELEPHONECONDUITS,HVAC

LINES,DUCTWORK,ORPOWERLINESTHATARE EXISTINGINTHEINTERIORAREASOFTHE APARTMENTTHATSERVICEOTHERPORTIONSOF THEBUILDING.

18.THEGENERALCONTRACTORSHALLBE RESPONSIBLETOPROTECTALLEXISTING WINDOWSTOREMAIN.CONTRACTORISTO PROTECTWINDOWSBEFORESTARTINGANY REMOVALORWORKINGENERALANDSHALLHAVE PROTECTIONOBSERVEDBYTHEOWNER'S REPRESENTATIVEPRIORTOSTARTOFWORK. CONTRACTOROROWNER'SREPRESENTATIVE SHALLMAKEADETAILEDPHOTOGRAPHIC INVENTORYOFTHECONDITIONOFTHEWINDOWS PRIORTOCONTRACTOR'SPROTECTIONBEINGPUT INPLACEANDTHESTARTOFWORK.

19.THEARCHITECTOFRECORDANDCONTRACTOR SHALLVERIFYTHATANYPORTIONOFWALLSTO BEDEMOLISHEDARENON-LOADBEARINGWALLS ANDANYNEWCONSTRUCTIONOFWALLSAND CEILINGSHALLFOLLOWNYCCODESAND REGULATIONSINCLUDINGBUTNOTLIMITEDTO ALLSOUNDPROOFING,WATERPROOFINGANDFIRE RATINGS.

20.IFSOMETHINGINDICATEDONTHEPLANOR DISCOVEREDINTHEFIELDISNOTSPECIFICALLY IDENTIFIEDTOBEREMOVEDORTOREMAINONTHE

PLANS,CONTRACTORSHALLREQUESTDIRECTION FROMARCHETYPEPRIORTOREMOVAL.

21.ARCHITECTISRESPONSIBLEFORTHETEMPORARY SHORINGDESIGN.SUBMITDETAILSANDDESIGN CALCULATIONSBEARINGTHESEALOFALICENSED PROFESSIONALORSTRUCTURALENGINEER'S REVIEWBEFORECONSTRUCTIONOFSHORING. 22.SAFETYZONE:ASAFETYZONESHALLBEPROVIDED AROUNDALLWORKAREASTOPREVENTPERSONS OTHERTHANWORKERSFROMENTERINGSUCH ZONE.WHEREWORKOCCURSONTHEEXTERIOR OFABUILDING,SUCHZONESHALLBEAPPROVED BYTHECOMMISSIONERPRIORTOTHE COMMENCEMENTOFWORK.

23.SEQUENCE:ANYSTRUCTURALMEMBERTHATIS BEINGDISMEMBEREDSHALLNOTSUPPORTANY LOADOTHERTHANITSOWNWEIGHT.NOWALL, CHIMNEY,OROTHERSTRUCTURALPARTSHALLBE LEFTINSUCHCONDITIONTHATITMAYCOLLAPSE ORBETOPPLEDBYWIND,VIBRATIONORANY OTHERCAUSE.THEMETHODOFREMOVALOFANY STRUCTURALMEMBERSHALLNOTDESTABILIZE REMAININGMEMBERS.ALLHANDLINGAND MOVEMENTOFMATERIALORDEBRISSHALLBE CONTROLLEDSUCHTHATITWILLNOTDEVELOP UNACCOUNTEDIMPACTLOADSONTHE STRUCTURE.

28.EXISTINGGASRISERINTHEKITCHENSHALLBE LOCATEDANDPROTECTEDFROMDAMAGEPRIOR TOTHESTARTOFWORK,ANDREMAINPROTECTED FORTHEDURATIONOFTHEPROJECT.

29.PRIORTOBEGINNINGDEMOLITIONOR CONSTRUCTION,PROTECTMECHANICALEXHAUST VENTSINTHEWORKAREASUSINGPLASTIC SHEETINGTOPREVENTDUSTMIGRATIONTO OTHERAREAS.

30.GENERALCONTRACTORTOCOMPLYWITH BUILDINGREGULATIONSONWHATDEMOLITION EQUIPMENTAREPERMISSIBLE.

KEYNOTES: ALLAPARTMENT

REMOVEINTERIORGLASSPARTITIONSINCLUDING MOLDINGS,BASEBOARDANDDOORS. D01

REMOVEALLFLOORING,BASEBOARD,CROWN MOLDINGANDWALLFINISHES.REPAIRANDPREP FORNEWFINISH. D02

REMOVEALLEXISTINGFLOOROUTLETS.D03

REMOVEPARTITIONWALLS,DOORS,MOLDINGS, ANDELECTRICALWIRING. D04

REMOVEALLEXISTINGELECTRICALOUTLETSON DEMOLISHEDWALLS. D05

REMOVEEXISTINGBASEBOARDRADIATOR COVERS,TOBEREPLACED. D06 D07ALLEXISTINGWINDOWSTOREMAIN. D08

REMOVEEXISTINGCLOSETINTERIORS.

BATHROOMS

REMOVEALLEXISTINGFINISHES,PLUMBING,AND DECORATIVEFIXTURES. D09

REMOVEALLEXISTINGPLUMBINGFIXTURESTUB SHOWERSINKTOILET.CAPANDRETURN EXISTINGPLUMBINGLINESBACKTORISER. D10

REMOVEEXISTINGCEILINGVENTSGRILLSIN ALLBATHROOMS,PROTECTALLBUILDINGDUCTS ANDSTRUCTURALELEMENTSDURING DEMOLITION.

INSPECTBUILDINGRISERLOCATIONS.ALLRISERS TOBEPROTECTEDATALLTIMESDURING DEMOLITION. D12

REMOVEEXISTINGWASHER/DRYER.CAPAND RETURNEXISTINGLINESBACKTORISER. D13

KITCHEN

CAPANDREMOVEEXISTINGGASRANGEBACKTO RISER.EXISTINGGASLOCKVALVETOREMAIN. PROTECTATALLTIMES. D REMOVEREFRIGERATORSUPPLYLINE,NEWLINE TOBELOCATEDINNEWLOCATION,. D

REMOVEALLEXISTINGAPPLIANCESAND FIXTURES:SINK,DISHWASHERANDWINECOOLER. CAPANDRETURNEXISTINGLINESBACKTORISER

REMOVEALLEXISTINGCABINETRY,

REMOVEALLEXISTINGSOFFITSANDDROP CEILINGS,DUCTWORK&EQUIPMENT.EXISTING STRUCTURALBEAMSTOREMAIN.PROTECTATALL TIMES.

REMOVEALLEXISTINGLIGHTINGFIXTURE,HVAC GRILLS,ACCESSPANELS,ANDCEILINGMOUNTED EQUIPMENT

REMOVEALLEXISTINGWALLSASMUCHAS POSSIBLEUPTOBUILDINGRISERS.ALLWALLSTO BEREFRAMEDASTIGHTASPOSSIBLE.ALLRISERS TOBEPROTECTEDATALLTIMESDURING DEMOLITION.

GRAPHICLEGEND:

EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN

EXISTINGINTERIORWALLSOR ELEMENTSTOBEREMOVED

NOTE:ALLWALLS&PARTITIONSBEING REMOVEDARENOTLOADBEARING.

ELECTRICALPANEL

EXISTINGDOORTOREMAINUNLESS NOTEDOTHERWISE

GENERALCONTRACTORTOCOORDINATEWITHBUILDING

MANAGERALLBUILDING'SREQUIREDPROGRESS INSPECTIONS:

·PREPARATIONOFDIRT&DUSTCONTROLPROCEDURES

·COMPLETIONOFDEMOLITIONANDFIRESTOPPINGAND FIREPROOFINGIFREQUIRED.

·COMPLETIONOFELECTRICALANDPLUMBINGROUGHIN COMPLETIONOFSOUNDPROOFINGAND WATERPROOFING

·COMPLETIONOFMECHANICALEQUIPMENT INSTALLATION

·COMPLETIONOFPROJECTPRIORTODOBAND ELECTRICALSIGN-OFF

18.SUPPLY&INSTALLNEWCUSTOMBASEMOLDINGS,PICTUREMOLDINGSANDDOORCASINGMOLDINGSTHROUGHOUTENTIRE APARTMENTASSHOWNINPLANS.DYKESOREQUAL.

19.ALLAREASUNCOVEREDBYWORKTHATAREDISCOVEREDTOBEMISSINGFIRESTOPPINGORINSULATIONMUSTBEADDRESSED.

20.GCTONOTIFYBUILDINGIFANYWORKNEEDSHOISTING.NOPROPOSEDWORKREQUIRESHOISTING.

21.THEPLYWOODTOBEADDEDFORBLOCKINGMUSTBEFIRE-TREATED

22.ASTHISISASPRINKLEREDBUILDING,NOTETHATFIBEROCKAQUA-TOUGHGYPSUMPANELS,MOLDTOUGHBOARDOREQUALMUSTBE USED.

23.ALLNEWSUSPENDEDCEILINGCONSTRUCTIONSHALLCONSISTOFSUPPORTINGHANGERRODS,CHANNELSANDGRIDASREQUIREDBY THENEWYORKCITYBUILDINGCODE.NOTETHATADHESIVE,MECHANICALANDSCREWANCHORSNOWREQUIREASPECIALINSPECTION BYACERTIFIEDINSPECTORPERSEC.BC1701OFTHE2014BUILDINGCODE.

24.ONLYWATER-BASEDSEALANTSMAYBEUSEDFOR(RE)FINISHINGOFWOODFLOORINGORCABINETRY.PRIORTOSANDINGAND REFINISHINGWOODFLOORING,ADUSTCONTAINMENTVESTIBULEANDNEGATIVEAIRPRESSUREMACHINESSHALLBEUTILIZEDPER MANUFACTURER'SGUIDELINESANDASDIRECTEDBYBUILDINGMANAGEMENTANDBUILDINGGUIDELINES.ALLOPENINGSINFLOORS, WALLSANDCEILINGSTHATCOULDLEADTODUSTESCAPINGTOOTHERAPARTMENTSORBUILDINGSPACESMUSTBESEALED. NEGATIVEAIRPRESSUREMACHINESREDUCEDUSTINFILTRATIONTOADJACENTUNITSANDPUBLICSPACESOUTSIDEOFTHEUNIT BEINGALTERED,PARTICULATEDUSTWITHINTHEWORKAREA,CLEANUPANDMAINTENANCETIME,ANDUNPLEASANTODORS. 25.THECONTRACTORISREQUIREDTOPROTECTALLPUBLICSTAIRWAYS/HALLWAYSPRIORTOSTARTOFDEMOLITIONUNTILALL ALTERATIONWORKISCOMPLETED.

26.G.CSHALLCONFIRMANDBERESPONSIBLETHATAFTERWORKHASBEENCOMPLETEDALLTHEEXISTINGANDNEWELECTRICAL EQUIPMENTSANDFIXTURES,INCLUDINGBUTNOTLIMITEDTO(APPLIANCES,HVACUNITS,AVEQUIPMENTS,ETC.)ARECONNECTED, FUNCTIONINGANDWORKING.

27.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTINGWALLANDFLOORSTHROUGHOUTAPARTMENT.

28.CONTRACTORSHALLSUPPLYCOORDINATEDSHOPDRAWINGSFORARCHITECTAPPROVALAT"=1'-0"INDICATINGTHEFOLLOWING: A)PARTITIONSB)LAYOUTOFLIGHTFIXTURES C)DUCTWORK,DIFFUSERSANDACCESSPANELSD)STRUCTURE

A50NEWFLOORTOREPLACEEXISTINGFLOOR.SEE FINISHPLAN.SEESCHEDULESFORSPECS.

A51INSTALLATIONOFNEWKITCHEN,BATHROOM,WETAREAS, FLOORINGMUSTINCLUDEADEQUATEWATERPROOFING. THEENTIREFLOORAREATOBEWATERPROOFEDWITHA LIQUIDAPPLIEDMONOLITHICMEMBRANESUCHAS LATICRETEHYDROBANORANAPPROVEDEQUIVALENT. WATERPROOFINGMUSTEXTENDNOFEWERTHAN(6) INCHESUPTHEPERIMETERWALLS.THEMEMBRANEMUST RUNWALLTOWALL,UNDERALLCABINETS,FIXTURES, TUBS,PANS,EQUIPMENT,RAISEDPLATFORMAND APPLIANCES,RETURN6"UPALLWALLSANDTO FULL-CEILINGHEIGHTINTHESHOWERAREA.THE WATERPROFFINGMUSTTIEINTOASUITABLEDOOR SADDLE.SEEDETAILSONP-100/101/102.

A52FORALLNEWWALLNICHEMEDICINECABINETSTORAGE FUTUREANSIREQUIREDBATHROOMGRABBARSG.C.TO PROVIDEBLOCKINGBRACKETSFRAMING.SEEELEVATIONS. G.C.TOCONFIRMWITHARCHITECTONDISCOVERIESOFANY UNFORESEENEXISTINGCONDITIONSDURINGDEMOLITIONOF WALLOPENINGS.G.C.TOPROTECTPATCHANDREPAIRALL OPENINGSCREATED.G.C.TOPROTECTPLUMBINGRISERS STRUCTURALELEMENTSDURINGDEMOLITIONSAND CONSTRUCTION.

PRIMARYBEDROOM

A37ELECTRICWATERVAPORFIREPLACE.W/KEF SPEAKERSINTEGRATEDINTOMILLWORK. SPEAKERSHARDWIREDTOGETHER. A38STORAGESHELVING

A39NOTUSED. A40NOTUSED. A41NOTUSED.

PRIMARYBATHROOM A42NEWVANITY/SINKWITHBUILT-INHAMPER,NEW TUB,NEWSELF-WASHTOILET,ALLTOBEINNEW LOCATION.PROVIDENEWROUGHINS,NEWLINES TOCONNECTTOEXISTINGRISER. A43NEWRADIANTHEATINGFLOOR.SEEFINISHPLAN A44BUILT-INMEDICINECABINET. A45ANTI-FOGLITMAKE-UPMIRROR. A46SURFACEMOUNTEDMAKEUPMIRRORON SWIVELARM A47ELECTROSTATICPRIVACYFILMINSTALLEDON SHOWERGLASSWALL.

A48BATHROOMFLOORRAISEDTOACC.BATHDRAIN BACKTORISER.SEEDETAILONP-102 A49NOTUSED

GLASSPARTITIONWITHETCHEDPATTERNAND METALACCENTSWITHSLIDINGDOORS

WIRINGASREQUIRED.

GLASSPARTITIONWITHETCHEDPATTERNAND METALACCENTS A09

BATHROOM#3

WALLNICHELOCATIONTOBEDETERMINEAFTER DEMOLITION A10

NEWSHOWERTOREPLACEWASHERDRYER LOCATION. A11

NORADIANTHEATINGFLOOR.A12

NEWSELF-WASHWALLHUNGTOILETINNEW LOCATION. A13

NEWBUILT-INMEDICINECABINET,VANITYINNEW LOCATION,DEPTHOFMEDICINECABINETTOBE DETERMINEAFTERDEMOLITION. A14

A15NEWCLOSETS A16NOTUSED KITCHEN

A17NOTUSED.

A18NEWMOVEABLEKITCHENBANQUETTE.WINDOWS TOBEACCESSIBLEFORMAINTENANCE.

A19NEWGASRANGETOBEREPLACEDINEXISTING LOCATION.REUSEEXISTINGAPARTMENTGAS LOCKVALVE

A20NEWKITCHENMILLWORKANDAPPLIACNESTOBE INSTALLED

A21NOTUSED LAUNDRY

A22INSTALLNEWWATERPROOFMEMBRANE (LATICRETE9235ORAPPROVEDEQUAL)AND SPECIFIEDSOUNDMATTING. INSTALLNEWSTACKWASHER/VENTEDDRYERIN NEWLOCATION.PLUMBERTOPROVIDE NECESSARYLEAKDETECTIONDEVICESANDPAN. SEESHEETA-101FORFLOORDETAILS. NEWROUGH-INSTOBEUSEDTOACCOMMODATE WASHERDRAINAGE.

BEDROOM#2

A23NEWWINDOWBENCHW/INTEGRATEDSTORAGE. A24TALLMILLWORKSTORAGEAROUNDCOLUMNS.

BATHROOM#2

A25NEWSELFWASHTOILET&SINKTOBEREPLACED INEXISTINGLOCATION,NEWSHOWERTO REPLACETUBINEXISTINGLOCATION.PROVIDE NEWROUGHINS.

A26NEWBUILTINMEDICINECABINET

A27NEWRADIANTHEATINGFLOOR,SEEFINISHPLAN

BATHROOM#1

A28NEWVANITY/SINK,SELF-WASHTOILET& SHOWERTOBEREPLACEINNEWLOCATION. PROVIDENEWROUGHINS,NEWLINESTO CONNECTTOEXISTINGRISER.

A29SHOWERW/BENCHANDSHOWERSHELF.

A30NEWSTEAMSHOWER

A31NEWRADIANTHEATINGFLOOR,SEEFINISHPLAN

A32BUILT-INMEDICINECABINET

A33ANTI-FOGLITMIRRORINSIDESHOWER.

A34VANITYWITHBUILT-INHAMPERFOGMIRROR ABOVEVANITY.

A35INSTALLBLOCKINGFORHANDLERBARSIN SHOWER

A36ELECTROSTATICPRIVACYFILMINSTALLEDON SHOWERGLASSWALL.

EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN

PITCH,1/4"/FT.(MINIMUM1/8")

A22
A37 A38

GENIEMATRST-5 GLUEDTOFF-10.

GENIEMATFF-10 DIMPLEDMAT.

EXISTINGCONCRETESLAB TOREMAIN.

FINISHFLOORKEYNOTES:

INDICATESAREA(S)TORECEIVENEW WATERPROOFMEMBRANEREQUIRED BYBUILDINGRULESANDREGULATIONS. SPECTOBEKEMPERORAPPROVED EQUIVALENT.SEEWATERPROOFING NOTESFORSPECIFICAPPLICATION INSTRUCTIONS.

INDICATESAREA(S)TORECEIVENEW CARPETEDFLOORINGONEXISTING WOODFLOORING.

INDICATESAREA(S)TORECEIVENEW RADIANTFLOORHEATING

GENERALWATERPROOFING&SOUNDPROOFINGNOTES:

1.WPSYSTEMSBYLATICRETE(9235ORAPPROVEDEQUAL)WILLGENERALLYBE ACCEPTABLE.HOWEVERTHEBATHROOMEXPANSIONSANDKITCHEN EXPANSIONS,WHICHWILLFIRSTNEEDTOPROVIDECONFIRMATIONTHAT PLUMBINGMAINTAINSSLABINTEGRITYANDPITCH,WILLREQUIRE EXTRAORDINARYMEASURES.

2.FORBATHROOMWETOVERDRYEXPANSIONS,WHICHWILLREQUIRE BUILDINGAPPROVALWEWILLCONSIDERTHEUSEOFALIQUIDMEMBRANE PRODUCTLIKEKEMPUR,PROVIDEDTHAT:I.ITISINSTALLEDOVERA SACRIFICIALLAYERANDNOTINSTALLEDDIRECTLYONTHESTRUCTURAL SLAB.

3.ALOWODORPRODUCTISSPECIFIEDANDALLPRECAUTIONSAREMADETO PROTECTAGAINSTODORINFILTRATION.ACERTIFIEDINSTALLERISTOBE USED.THEDRAINISTOBEAPPROVEDBYTHEMANUFACTURER.KEMPER CANNOTBELAYEREDOVEROTHERWATERPROOFINGMATERIALSLIKE LATICRETEASTHEYARENOTCOMPATIBLEANDMAYTRAPMOISTURE. 4.PLEASECONFIRMHOWTHEEXPANSIONOFTHEKITCHENINTOTHEDINING AREAWILLADDRESSWATERPROOFINGANDWHERETHEWATERPROOFING MEMBRANEFROMTHEKITCHENWILLTERMINATE?ITDOESLOOKASTHOUGH THEWETFIXTURESARECONTAINEDWITHINTHEORIGINALKITCHEN FOOTPRINTBUTTHISNEEDSTOBECONFIRMED. 5.THEUSEOFASTEAMUNITISPROPOSED.THISWILLREQUIREBOARD APPROVAL.IFAPPROVEDBYTHEBOARD,THEUNITMUSTSITWITHINA WATERPROOFPANWITHANAUTOMATICSENSORALARMANDSHUT-OFF,AND THEUNITMUSTBEACCESSIBLE.LOCATETHESTEAMUNITINPLANAND SHOWPROVISIONFORACCESS.PROVIDESTEAMUNITSPECIFICATIONS,AS WELLASSPECIFICATIONSFORVIBRATIONISOLATORS(MASONINDUSTRIES OREQUAL)TOBEUSEDUNDERTHEUNIT.ELECTRICALSERVICETOTHE APARTMENTSHALLBEVERIFIEDASSTEAMUNITSAREHIGHDRAW APPLIANCES.THECONSTRUCTIONSHALLCOMPLYWITHTHEFOLLOWING REQUIREMENTS.THEENTIREENCLOSURESHALLHAVEVAPORBARRIER

INSTALLEDATWALLSANDCEILING.THEVAPORBARRIERMUSTOVERLAPTHE SHOWERLEADPAN.THEENTIREENCLOSURESHALLBECONSTRUCTEDOF CEMENTITIOUSWALLBOARDSUCHASDUROCK,ORAPPROVEDEQUALTHAT ISRATEDFORSTEAMSHOWERUSEATALLWALLSANDCEILING.THEENTIRE ENCLOSURESHALLBEWATERPROOFEDWITHLATICRETE9235ATFLOOR, WALLSANDCEILING,INCLUDINGNICHES,BENCHES,ETC.USEIMPERVIOUS FINISHTILESANDSURFACESTHROUGHOUTTHESTEAMSHOWER.INSTALL WATERPROOFTHERMALINSULATIONINWALLANDCEILINGFRAMING.THE CEILINGISRECOMMENDEDTOPITCHAMINIMUMOF2"PERFOOTTO PREVENTDRIPPINGOFHOTWATERONTOOCCUPANTS.

6.ALLSHOWERSSHALLHAVELEADPANSWHICHMUSTBECLAMPEDAND SEALED,ORSOLDERED,INTOANEWDRAINCOLLARANDMUSTCAPOVER THECURBEXTENDINGAMIN.OF4"UPTHEWALLABOVETHETOPOFCURB WHICHWILLDETERMINETHEHEIGHTATTHEPERIMETERSHOWERWALLS NOTETHATTHECURBMUSTBECONSTRUCTEDOFFORMEDCONCRETEAND THATWOODBLOCKINGMAYNOTBEUSED.NOTETHATTHEDRAINMUST HAVEWEEPHOLES.AFTERPASSINGA24-HOURWATERRETENTIONTEST, WITNESSEDBYTHERESIDENTMANAGER,THEENTIRELEADPANMUSTBE COATEDWITHASUITABLEWATERPROOFMASTICMEMBRANEPRIORTO INSTALLATIONOFTHEMORTARBEDTHEUNITOWNER'SREPRESENTATIVEIS TOSPECIFYAPRODUCTTHATISAPPROPRIATEFORCOATINGLEANPANS FORSHOWERSTHATWILLPROTECTTHELEADPANAGAINSTFUTURE CORROSION(NOTE:WE'VECONFIRMEDWITHLATICRETETHATHYDROBANIS NOTAPPROPRIATEFORTHISANDWEAREAWARETHATSOMEPEOPLEUSE MASTERSEALHLM500.ATAR-BASEDMASTICISAPPROPRIATE).TYPICALLY, THECOATEDLEADPANWILLBECOVEREDEITHERWITHACEMENTITIOUS MUDSETFORSTONESLABFLOORINGORTHINSETFORTILE.WHERENICHES AREPROPOSEDFORTUBANDSHOWERENCLOSURES,PROVIDE WATERPROOFINGTHROUGHOUTENTIRENICHE,ANDEXTENDINGAROUND ALLSIDESOFTHENICHEFACETOFORMACONTINUOUSMEMBRANEWITH

THEWATERPROOFINGMEMBRANEREQUIREDATTHESHOWER.SLOPE BOTTOMOFNICHETODRAIN.ATSHOWERBENCHESTHATFORMA CONTIGUOUSBOX-OUTWITHINTHESHOWERFOOTPRINT,THELEADPAN MUSTWRAPAROUNDALLSIDESOFTHEBENCHANDEXTENDAMINIMUMOF 4"UPTHEPERIMETERWALLSATTHETOPOFTHEBENCHASWELLAS ACROSSTHESIDEWALLSONTHEVERTICALPLANES.

7.THEAREAWITHINTHEWALLBELOWTHETANKOFABACKOUTLETTOILET ANDALLPLUMBINGLINESMUSTBEWATERPROOFED.THEWATERPROOFING AROUNDTHETANKMUSTEXTENDAMINIMUMOF12"ABOVETHEFLUSH VALVE.PENETRATIONSFORFASTENERSANDPIPINGMUSTBEFULLYSEALED.

8.FORFREEZERICEMAKERONLYCOPPERTUBINGMAYBEUSEDANDACCESS MUSTBEPROVIDEDFORFLUSHINGOUTTHESYSTEMANDCONFIRMINGNO LEAKS.

9.FORSOUNDPROOFING,WERECOMMENDTHATPRODUCTSMEETOREXCEED CODE.GENIEMATRST10(10MM);KINETICSSRFLOORBOARD5/8"THICK; COLBONDENKASONIC9110,10MM;QUIETCORK(JELINEKCORKGROUP),6MM; ANDSIKAACOUBOND(FORWOODFLOORSONLY).NOTETHATTHEEXISTING BUILDING'SFLOORCONSTRUCTIONANDTHESP'SPERFORMANCEUNDER WETCONDITIONSMUSTBECONSIDEREDINTHESELECTIONOFTHE APPROPRIATESOUNDPROOFINGPRODUCTFORWHICHTESTDATABASEDON REQUIREMENTSPRESCRIBEDBYTHENEWYORKCITYBUILDINGCODEMUST BEPROVIDED.PERIMETERISOLATIONISTOBEEMPLOYEDFORTHE INSTALLATIONOFALLSOUNDPROOFING.THESPINSTALLATIONMUSTBE INSPECTEDBYTHERESIDENTMANAGERPRIORTOTHEFINISHFLOORING INSTALLATION 10.SPEAKERS/SUBWOOFERS:PROVIDENECESSARYSOUNDISOLATIONTO ASSURETHATTHEREISNOSTRUCTURE-BORNENOISETRANSMITTANCE, WHICHISALIKELYOCCURRENCEWITHTHISEQUIPMENT,SUBWOOFERS MUSTBEMOUNTEDONMASONINDUSTRIESTYPESLFMETALSPRINGSOR EQUAL,SIZEDFORAMINIMUMDEFLECTIONOF1"UNDERTHEWEIGHTOFTHE

SPEAKERANDTHEBASE.THEMOUNTINGBASEMAYNEEDTOINCLUDESAND

INWTAREAS:LATICRETE9235

WATERPROOFINGMEMBRANE SHALLBETURNEDUPWALL6"

NEWFLOORTILES MUDSET GROUT

GENIEMATRST-5

GENIEMATFF-10 DIMPLEDMAT.

EXISTINGCONCRETESLAB TOREMAIN.

WATERRESISTANT GYP.BD. THINSET NEWWALLTILES PROVIDEPEROMETERISOLATIONAND ACOUSTICALSEALANTASPER MANUFACTURERSPECS. NEWFLOORTILES GROUT MUDSET

LATICRETEWATERPROOF MEMBRANEWITHFABRIC REINFORCEMENT

EXISTINGCONCRETE SLABTOREMAIN

GENERALFLOORINGNOTES:

1.ALLWORKSHALLBEINACCORDANCEWITHALLSTATEANDLOCALCODES. 2.COORDINATE&SUPERVISEALLTRADESANDPROVIDETHEDESIGNATED CLEARANCESSHOWNONTHESEDOCUMENTS.G.C.SHALLINFORMARCHETYPE PRIORTOPROCEEDINGWITHWORKTHATDIFFERSFROMTHEDESIGNINTENT.

3.ALLDIMENSIONSARETOBETAKENFROMFACEOFFINISHEDGYP.BOARDUNLESS OTHERWISEINDICATED.

4.PREPAREALLSURFACESFORFINISHESPERMANUFACTURERSPECIFICATIONS.

5.APPLY(3)COATSOFCLEARPOLYURETHANETONEWWOODFLOORSTHROUGHOUT ENTIREAPARTMENT.FLOORSTOBEPROTECTEDDURINGCONSTRUCTIONAS REQUIRED.USEWATERBASEDPOLYURETHANEONLY,ASREQUIREDBYBUILDING. 6.SEALALLPENETRATIONSTHROUGHALLFLOORS,WALLS&DOORS&ALLREDUCING STRIPSWHERECHANGESINFLOORFINISHESOCCUR.SUBMITSAMPLESFOR APPROVALTOARCHETYPE.

7.FLASH,PATCHANDLEVELTHEFLOORSASREQUIREDFORNEWFLOORFINISHES.

8.SUPPLYALLCONSTRUCTIONMATERIALSINCLUDINGBUTNOTLIMITEDFLOORING COMPOUNDS,GROUT,AND/ORGLUEASREQUIRED.

9.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTING FLOORSTHROUGHOUTAPARTMENT.

10.ALLFLOORFINISHESMUSTBEATTHESAMEFINISHELEVATIONUNLESSNOTED OTHERWISE.NOTIFYARCHETYPEIFTHISCANNOTBEACHIEVEDSOTHATANY DETAILSCANBEMODIFIEDACCORDINGLY. 11.FLOORINGTOEXTENDUNDERMILLWORKANDAPPLIANCES(TYPICAL).

18.SUPPLY&INSTALLNEWCUSTOMBASEMOLDINGS,PICTUREMOLDINGSANDDOORCASINGMOLDINGSTHROUGHOUTENTIRE APARTMENTASSHOWNINPLANS.DYKESOREQUAL.

19.ALLAREASUNCOVEREDBYWORKTHATAREDISCOVEREDTOBEMISSINGFIRESTOPPINGORINSULATIONMUSTBEADDRESSED.

20.GCTONOTIFYBUILDINGIFANYWORKNEEDSHOISTING.NOPROPOSEDWORKREQUIRESHOISTING.

21.THEPLYWOODTOBEADDEDFORBLOCKINGMUSTBEFIRE-TREATED

22.ASTHISISASPRINKLEREDBUILDING,NOTETHATFIBEROCKAQUA-TOUGHGYPSUMPANELS,MOLDTOUGHBOARDOREQUALMUSTBE USED.

23.ALLNEWSUSPENDEDCEILINGCONSTRUCTIONSHALLCONSISTOFSUPPORTINGHANGERRODS,CHANNELSANDGRIDASREQUIREDBY THENEWYORKCITYBUILDINGCODE.NOTETHATADHESIVE,MECHANICALANDSCREWANCHORSNOWREQUIREASPECIALINSPECTION BYACERTIFIEDINSPECTORPERSEC.BC1701OFTHE2014BUILDINGCODE.

24.ONLYWATER-BASEDSEALANTSMAYBEUSEDFOR(RE)FINISHINGOFWOODFLOORINGORCABINETRY.PRIORTOSANDINGAND REFINISHINGWOODFLOORING,ADUSTCONTAINMENTVESTIBULEANDNEGATIVEAIRPRESSUREMACHINESSHALLBEUTILIZEDPER MANUFACTURER'SGUIDELINESANDASDIRECTEDBYBUILDINGMANAGEMENTANDBUILDINGGUIDELINES.ALLOPENINGSINFLOORS, WALLSANDCEILINGSTHATCOULDLEADTODUSTESCAPINGTOOTHERAPARTMENTSORBUILDINGSPACESMUSTBESEALED. NEGATIVEAIRPRESSUREMACHINESREDUCEDUSTINFILTRATIONTOADJACENTUNITSANDPUBLICSPACESOUTSIDEOFTHEUNIT BEINGALTERED,PARTICULATEDUSTWITHINTHEWORKAREA,CLEANUPANDMAINTENANCETIME,ANDUNPLEASANTODORS. 25.THECONTRACTORISREQUIREDTOPROTECTALLPUBLICSTAIRWAYS/HALLWAYSPRIORTOSTARTOFDEMOLITIONUNTILALL ALTERATIONWORKISCOMPLETED. 26.G.CSHALLCONFIRMANDBERESPONSIBLETHATAFTERWORKHASBEENCOMPLETEDALLTHEEXISTINGANDNEWELECTRICAL EQUIPMENTSANDFIXTURES,INCLUDINGBUTNOTLIMITEDTO(APPLIANCES,HVACUNITS,AVEQUIPMENTS,ETC.)ARECONNECTED, FUNCTIONINGANDWORKING.

27.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTINGWALLANDFLOORSTHROUGHOUTAPARTMENT. 28.CONTRACTORSHALLSUPPLYCOORDINATEDSHOPDRAWINGSFORARCHITECTAPPROVALAT"=1'-0"INDICATINGTHEFOLLOWING: A)PARTITIONSB)LAYOUTOFLIGHTFIXTURES C)DUCTWORK,DIFFUSERSANDACCESSPANELSD)STRUCTURE

EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN

CEILING/ELECTRICNOTES:

1.THECONTRACTORSHALLVERIFYALLCONDITIONSFORCLEARANCEOFMECHANICALUNITS,DUCTWORK,PIPING,ETC,ANDNOTIFYTHEARCHITECTOF ANYDISCREPANCIESPRIORTOPROCEEDING.

2.REFERTOLIGHTFIXTURESCHEDULE&INSTALLINACCORDANCEWITHMANUFACTURER'SDIRECTIONS.

3.DIMENSIONSARETOTHECENTERLINEOFTHEFIXTURE,UNLESSOTHERWISENOTED.

4.VERIFYMAXIMUMACHIEVABLECEILINGHEIGHTSATTHEBEGINNINGOFCONSTRUCTIONANDNOTIFYARCHITECTIFANYCONDITIONSPREVENTTHE PROPOSEDHEIGHTSTOBECONSTRUCTED.ALLCEILINGHEIGHTSGIVENAREASSUMED,TOBEVERIFIEDONCEALLMECHANICALEQUIPMENTAND DUCTINGHAVEBEENINSTALLED.

5.ALLCEILINGHEIGHTSSHALLBEMEASUREDFROMTHEFINISHFLOORLEVELOFTHESPACEDESIGNATED.

6.PARTITIONSSHALLNOTBESECUREDORATTACHEDINANYWAYTODUCTWORK.

7.ALLSMOKEDETECTORS,DIFFUSERSANDGRILLESSHALLBECENTEREDAND/ORALIGNEDWITHSURROUNDINGARCHITECTURALELEMENTSU.O.N.

8.COORDINATELIGHTINGWITHENGINEER'SDRAWINGS,LUTRON'SSUBMITTALS&DECORATIVELIGHTINGSCHEDULE.

9.ALLCEILINGSSHALLBELEVELANDINALIGNMENT.PROVIDEFIRERATEDHOUSINGFORRECESSEDLIGHTSORPROTECTIVEFIRERATEDENCLOSURES. MAINTAINFIRERATINGOFCEILING.

10.COORDINATELIGHTFIXTURELAYOUTWITHLAYOUTOFPIPESANDEQUIPMENT.

11.PROVIDEBLOCKINGATALLHANGINGFIXTURELOCATIONS.

12.LIGHTFIXTURESINSMALLSPACES(I.E.CLOSETS,VESTIBULES,UTILITYROOMS,ETC.)SHALLBECENTEREDINTHESPACEUNLESSOTHERWISENOTED.

13.ALLHARDWIREDCARBONMONOXIDEDETECTORSSHALLCOMPLYWITHRS17-13ANDBEINSTALLEDINACCORDANCEWITH17-14&LL/2004. 14.REFLECTEDCEILINGPLANSAREFORCOORDINATIONPURPOSESONLYREFERTOENGINEERINGDRAWINGSFORLIGHTING,HVAC,SPRINKLER,ETC. 15.SUPPORTWIRESFORCEILINGMUSTNOTBECONNECTEDTOANYMECHANICAL,ELECTRICAL,PLUMBING,FIREPROTECTION,PIPINGANDEQUIPMENT.

16.WHERENOTED,WINDOWSTORECEIVEMOTORIZEDSHADESTOBECOORDINATEDWITHA.V.CONSULTANT. 17.G.C.'SELECTRICIANTOBERESPONSIBLEFORRUNNINGALLWIRINGFORALLSWITCHANDKEYPADLOCATIONS.COORDINATEWITHAVCONSULTANT INCLUDINGMOTORIZEDSHADESWITHBLACKOUTS.PROVIDEALLELEC.OUTLETSANDCABLE,HDMI,INTERNETOUTLETSATTVHEIGHTSASINDICATED. TVMOUNTINGHEIGHTSTOBEDETERMINEDWITHOWNER.PROVIDEREQUIREDFRAMINGANDBLOCKINGFORALLWALLHUNGTV'S.INSTALLOWNER SUPPLIEDBRACKETSANDTV'S.

SYMBOLLEGEND:

CHANDELIERPENDANTFIXTURE

SURFACEMOUNTEDCEILINGFIXTURE

WALLSCONCETYP.

WALLSCONCE@BATHROOM

WALLSCONCEEXTERIOR CLOSETLIGHTFIXTUREW/JAMBSWITCH

IN-GROUNDEXTERIORFIXTURE

RECESSEDLIGHT-ROUNDTRIM

RECESSEDLIGHTSQUARETRIMLESS

*NOTE:USEWATERPROOFHOUSINGANDTRIM

FORALLRECESSEDLIGHTSINWETAREAS

CLOSETSURFACEMOUNTEDFIXTURE

CLOSETLIGHTWALLMOUNTED

UNDERCABINET/STRIPLIGHT

EXTERIORWALLSCONCE EXT

EXTERIORFLOODLIGHT

POWERNOTES:

1.THECONTRACTORSHALLVERIFYALLCONDITIONSFORCLEARANCEOFMECHANICALUNITS,DUCTWORK,PIPING,ETC,ANDNOTIFYTHEARCHITECTOF ANYDISCREPANCIESPRIORTOPROCEEDING.

2.REFERTOLIGHTFIXTURESCHEDULE&INSTALLINACCORDANCEWITHMANUFACTURER'SDIRECTIONS.REFERTORCPFORLOCATIONS.

3.DIMENSIONSARETOTHECENTERLINEOFTHEFIXTURE,UNLESSOTHERWISENOTED.

4.SUPPORTWIRESFORCEILINGMUSTNOTBECONNECTEDTOANYMECHANICAL,ELECTRICAL,PLUMBING,FIREPROTECTION,PIPINGANDEQUIPMENT.

5.LOWVOLTAGEWIRINGANDEQUIPMENTTOBECOORDINATEDWITHTHEA.V.CONSULTANT.

6.WHERENOTED,WINDOWSTORECEIVEMOTORIZEDSHADESTOBECOORDINATEDWITHA.V.CONSULTANT.

7.G.C.'SELECTRICIANTOBERESPONSIBLEFORRUNNINGALLWIRINGFORALLSWITCHANDKEYPADLOCATIONS.COORDINATEWITHAVCONSULTANT INCLUDINGMOTORIZEDSHADESWITHBLACKOUTS.PROVIDEALLELEC.OUTLETSANDCABLE,HDMI,INTERNETOUTLETSATTVHEIGHTSASINDICATED. TVMOUNTINGHEIGHTSTOBEDETERMINEDWITHOWNER.PROVIDEREQUIREDFRAMINGANDBLOCKINGFORALLWALLHUNGTV'S.INSTALLOWNER SUPPLIEDBRACKETSANDTV'S.

8.ALLELEC.OUTLETSINWETAREASSHALLBEG.F.I.TYPEASREQUIREDBYELECTRICALCODEANDASPERPLAN.

9.ALLEXISTINGELECTRICALRECEPTACLESNOTAFFECTEDBYNEWCONSTRUCTIONSHALLREMAIN(UNLESSOTHERWISENOTED).

SYMBOLLEGEND:

*OUTLETSTOBE"SCREWLESS"ASPEROWNER

ELECTRICALOUTLETDUPLEX

KEYNOTES: ALLAPARTMENT P01 P02

NEWOWNER-SUPPLIEDTV/SONOSBARWITHIN CUSTOMBEDMILLWORKINLIFTCABINET.

10 P P P P P P P P

CURRENTEXISTINGFLOORISRAISED,NEWFLOOR OUTLETSTOUTILIZERAISEDFLOOR 03 DEDICATEDOUTLETSFORAPPLIANCESAS INDICATED. 04

PROVIDEELECTRICSOURCEFORNEWRADIANT HEATUNDERNEWSTONEFLOORASINDICATED. SEEFINISHFLOORFORAREAOFHEATEDFLOOR. 05

PLUGMOLDSINTEGRATEDUNDERDESK/ CABINETRY. 06

07DEDICATEDAVRACKLOCATIONFORAV&SHADE COMPONENTS.120V20AMPDEDICATEDOUTLET. 08DEDICATEDOUTLETFORBIDET

PIANOTOBEWIREDBACKTOSPEAKERS THROUGHSONOSPORTFORALTERNATIVE CONNECTION.

LITMIRRORFOGMIRRORINSHOWER.PROVIDE POWER.

PROVIDEPOWERANDSWITCHFORHEATING LIGHTABOVESHOWER. P11

PROVIDEPOWERANDSWITCHFOR ELECTROSTATICPRIVACYFILMONGLASS. P12

NEWOWNER-SUPPLIEDSONOS)POWERED SUBWOOFERWITHPOWERCABLESRUNBY ELECTRICIANASNEEDED. P13

P14NOTUSED.

NEWOWNER-SUPPLIEDPOWEREDSONOS SPEAKERSINTEGRATEDINCUSTOMMILLWORK WITHPOWERANDDATACABLESRUNBY ELECTRICIANASNEEDED. P15

P16PROVIDEPOWERFOROPTI-MYSTFIREPLACE.

-NEWELECTRICTHROUGHAPARTMENTASPERCODE. -ALLOUTLETSTOBEINTEGRATEDINBASEBOARD UNLESSOTHERWISEINDICATED. -ALLOUTLETSINKITCHENANDINBATHROOMSTOBE GFI -OUTLETSINBATHROOMPAINTEDTOMATCHWALL FINISH -ALLFLOOROUTLETSTOBEFLUSHWITHFINISHFLOOR

CABLELINE

ELECTRICALPANEL

INTERCOM-2CAT6 D IN-FLOORELECTRICALOUTLETSINGLE IN-FLOORELECTRICALOUTLETDUPLEX

DATA/INTERNET1CAT61RG6 (COORDINATEWITHAVCONSULTANT)

TV4CAT6WIRES TV SP

ELECTRICALOUTLET*QUAD. M MOTORFORSHADES(COORDINATEWITHAV CONSULTANT)

SPEAKER-1-16/4SPEAKERWIRE(COORDINATE WITHAVCONSULTANT)

WIFIACCESSPOINT

GENERALPLUMBINGNOTES:

ELECTRICALWORKWILLBEPERFORMEDBYANEWYORKCITYLICENSEDELECTRICIAN. 10.ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSORTENANTSSHALL REMAINTHROUGHOUT.ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,PROTECTDURING CONSTRUCTION.(ALLLOCATIONSOFPLUMBINGRISERSSHOWNONPLANSAREASSUMED,NOTVISIBLE ATTIMEOFFIELDSURVEY).EXPLOREANDVERIFYRISERLOCATION,IFANYSPACECANBEGAINED. 11.BRANCHPIPINGREPLACEMENTFORTHEKITCHENANDBATHROOM,NEWSHUTOFFVALVESFOREACH BRANCHLINEANDASHUTOFFVALVEATTHERISER;MECHANICALWATERHAMMERARRESTORS;SPRING LOADEDCHECKVALVESINTHEHOTANDCOLD-WATERPIPINGFROMTHERISERTEES;ANDREPLACING THEDRAINANDPLUMBINGVENTPIPING.ALLNEWANDEXISTINGVALVESSHALLHAVEAFIRERATED ACCESSPANEL.THENEWSHOWERMUSTHAVETHEDRAINANDTRAPINSTALLEDANDTHETOILETWILL REQUIREANEWLEADBEND.

12.PLEASEENSURETHATALLACCESSISMAINTAINEDTOALLSHUT-OFFVALVES,LOCALLYATEACH FIXTUREANDGENERALLY.ANYPIPINGINSULATIONDISTURBEDMUSTBERESTORED.

13.NEWBRANCHPIPINGISTOINCLUDEPROVIDINGNEWRISERSHUT-OFFVALVESAMINIMUMOF4ELBOW SWINGSTOALLOWFORVERTICALEXPANSIONAREREQUIREDBETWEENTHEHOTWATERRISERTAND SHUT-OFFVALVE.PROVIDEDIELECTRICUNIONSWITHAPPROPRIATEENDCONNECTIONSFORTHEPIPE MATERIALSINWHICHINSTALLED(SCREWED,SOLDERED,ORFLANGED)TOISOLATEDISSIMILARMETALS. SOFT-SEATED,SPRING-LOADEDSWINGCHECKVALVESARETOBEPROVIDEDONHOTANDCOLDWATER BRANCHLINESFOLLOWINGTHESHUT-OFFVALVES.ALLVALVESARETOBEMADEACCESSIBLEFOR SERVICING.BRANCHPIPINGISTOBEWRAPPEDWITHDURABLE,CONDENSATECONTROLLING, INSULATINGMATERIALANDSUPPORTEDWITHNON-REACTIVEMATERIALS.AMINIMUMCLEARDISTANCE OF2"ISREQUIREDBETWEENHOTANDCOLDWATERPIPESANDTHEREMUSTBENOMETAL-TO-METAL CONTACTBETWEENPIPING,CONDUIT,BX,ETC.AWATERHAMMERARRESTERISTOBEPROVIDEDATALL BRANCHLINESTHATFEEDSINKS,LAVATORIESANDWATERCLOSETS.ARRESTERSMUSTBEMADE ACCESSIBLEFORSERVICING(UNLESSTHEUNITHASALIFETIMEGUARANTEEI.E.SIOUXCHIEF)ANDARE TOBELOCATEDACCORDINGTOMANUFACTURER'SINSTRUCTIONS. 14.NEWBRANCHPLUMBINGPIPINGISTOBELOCATEDOUTBOARDOFALLRATEDDEMISINGPARTITIONS.

GRAPHICLEGEND:

SANITARYDNBRANCHLINE

SUPPLYHOTWATER&COLDWATERBRANCHLINE

VDNBRANCHLINE

PLUMBING-DIRECTIONOFSUPPLYDRAINLINES

PLUMBING-DIRECTIONOFGASLINES

AREAOFRAISEDFLOORFORPLUMBING.

WATERPROOFINGMEMBRANE

SEAMLESS,CONTINUOUSLEADPAN(6LBS./FT.) EXTENDED6"UPWALLS(CORNERSSOLDERED). FIFTEENPOUNDROOFINGFELTBETWEENPAN ANDCONCRETE.PLUGDRAINANDTESTFOR WATERTIGHTNESSFOR24HRS.COATPAN WITHASPHALTPAINTTOPREVENT ELECTROLYSISANDCORROSION. METALSTUD 5/8"CONCRETE BACKERBOARD LEADPAN THINSET MORTARBED LATICRETE9235 WATERPROOFINGMEMBRANE

LIGHTWEIGHTCONCRETEFILL 4" 2"

3B/P-101-STEAMUNITMEDICINECABINETDETAIL

LINEOFTOPEDGEOFLEADPANLINER12" ABOVEFLOORANDTOCEILINGAROUNDSHOWER

NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE. 5CONC.BACKERBOARD NEWSTONESLABONWALLS.

LIGHTWEIGHTCONCRETEORFIRERATEDFOAM FILLTOFORM&SHAPESHOWERBED

CEMENTBACKERBOARDASSACRIFICIALLAYER FORWATERPROOFMEMBRANE.KEMPER2K-PUR WATERPROOFMEMBRANERUNFULLHEIGHTIN BATHROOM

NEWSHOWERDRAINCONNECTEDTOEXISTING DRAINLINE.LIGHTWEIGHTCONCRETEFORINFILL.

LATICRETE'9235'WATERPROOFING/LATICRETE 'HYDROBAND'WATER-PROOFINGONSHOWER SURFACESANDWALLSUPTOCEILING.

KEMPER2K-PURWATERPROOFMEMBRANERUN FULLHEIGHTINBATHROOM&SHOWERON SACRIFICIALLAYER.

5B/P-101-BATHROOMSADDLEDETAIL

EXISTINGCONC.SLABTOREMAIN

BRACINGANDBLOCKINGASREQ'D.

FLEXIBLEFOAMBACKERROD&TILESEALANT EXPANSIONJOINT.

STEAMOUTLET WATERINLET

MANUALBALL-TYPESHUT-OFFVALVE

STUDFRAMINGWITHPIPING

BLOCKINGASREQ'D.

RECESSEDLIGHTFIXTURE

CEILINGTOBESLOPED2"PERFT.

TILEONTHINSETSLOPENINTOSTEAMSHOWER.

LATICRETE'9235'WATERPROOFING/LATICRETE 'HYDROBAND'WATER-PROOFINGONSHOWER SURFACESANDWALLSUPTOCEILING.

KEMPER2K-PURWATERPROOFMEMBRANERUN FULLHEIGHTINBATHROOM

LEAKDETECTORWITHAUDIBLEALARM LEADPANCOVEREDWITHLIQUIDWP MEMBRANE

VIBRATIONISOLATIONPAD

SOUNDMATUNDERLAYMENT. AUTOMATICSHUT-OFFVALVE

EXISTINGSLABWITHCEMENTBACKER BOARDASSACRIFICIALLAYERFOR WATERPROOFMEMBRANE.KEMPER 2K-PURWATERPROOFMEMBRANERUN FULLHEIGHTAROUNDSTEAMUNIT.

NOTE: 1.STEAMUNITINSTALLEDPERMANUFACTURERSSPECS 2.UNITTOBEINSTALLEDWITHINWATERPROOFPANW/ AUTOMATICSENSORALARMANDSHUT-OFF. 3.UNITMOUNTEDONVIBRATIONISOLATORS(MASON INDUSTRIESOREQUAL). 4.STEAMUNITTOBEACCESSIBLE.

2A/P-101-STEAMSHOWERCEILINGDETAIL

LINEOFTOPEDGEOFLEADPANLINER12" ABOVEFLOORANDTOCEILINGAROUNDSHOWER

NEWSTONESLABONSHOWERWALLSON THINSETBACKERBOARD.

LIGHTWEIGHTCONCRETEFILLOR FORM&SHAPESHOWERBED CEMENTBACKERBOARDASSACRIFICIALLAYER FORWATERPROOFMEMBRANE.KEMPER2K-PUR WATERPROOFMEMBRANERUNFULLHEIGHTIN BATHROOM NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE. "CONC.BACKERBOARD

EXISTINGCONC.SLABTOREMAIN

CRUSHEDGRAVELATWEEP HOLES.

NEWREINFORCEDMORTARBED SLOPEDTODRAIN1 4PERFT.

LIGHTWEIGHTCONCRETEOR FIRERATEDFOAMFILLTO FORM&SHAPESHOWERBED

NEWTILESONWALLS

LATICRETE'9235'WATERPROOFING/ LATICRETE'HYDROBAND'WATER-PROOFING RUNUPWALLSUPTO12"ABOVEFINFLOOR

5 8CONC.BACKERBOARD

NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE

CEMENTBACKERBOARDASSACRIFICIAL LAYERFORWATERPROOFMEMBRANE. KEMPER2K-PURWATERPROOFMEMBRANE RUNUPWALLSUPTO12"ABOVEFINFLOOR

EXISTINGCONCRETESLABTOREMAIN.

ALUMINUMANGLEATEDGEOF SADDLE. TURNUPWATERPROOFINGMEMBER 90DEGREES@DOORSADDLE NOTE: USEKEMPERCERTIFIEDINSTALLEDFORALLKEMPER INSTALLATION

NEWWALL-TO-WALL CARPET

GENIEMATRST-5 GLUEDTOFF-10.

GENIEMATFF-10 DIMPLEDMAT.

EXISTINGFINISHFLOOR TOREMAIN

EXISTINGCONCRETESLABTO REMAIN.NOCHANNELINGOR PENETRATIONPERMITTED.

NEWFLOORSLABONRAISEDFLOOR

LATICRETE'9235'WATERPROOFING/ LATICRETE'HYDROBAND'WATER-PROOFING RUNUPWALLSUPTO12"ABOVEFINFLOOR

5 8CONC.BACKERBOARD

NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE

KEMPER2K-PURWATERPROOFMEMBRANE RUNUPWALLSUPTO12"ABOVEFINFLOOR

CEMENTBACKERBOARDASSACRIFICIAL LAYERFORWATERPROOFMEMBRANE.

HAVECUSTOMMTL FINGERPULLS SEEDETAIL2/A-401

GLASSSHELVESW/ RECESSEDLIGHTS CLADWALLW/ STONE.ST-06.

RECESSEDMEDICINE CABINETBYGCW/ MATCHINGMIRRORS.

DMSELENESCONCES MOUNTEDONEITHER SIDEOFVANITY

CUSTOMVANITYBY GC.SEEA-406FOR DETAILS.

OWNERSUPPLIED MAKE-UPMIRROR

RAISEDTO ACCOMMODATE FREESTANDING TUBPLUMBING. SEEP-102.

GLASSTORECEIVE ELECTROSTATICPRIVACYFILM, WIREDBYELECTRICIAN. GLASSSPLITINTO3PIECES ALONGFILMLINE.

WHTLACQ.TOUCHLATCH

LEDLIGHTSUNDERCABINET

FLOATINGGLASSSHELVES

GLASSTORECEIVE ELECTROSTATIC PRIVACYFILM. SPLITINTO3PIECES ALONGPRIVACYFILM. DMSELENESCONCES MOUNTEDONEITHER

DMSELENESCONCES MOUNTEDONEITHER SIDEOFVANITY

WHITELACQUER LAUNDRYHAMPERW/ STONECOUNTERTOP

SHOWERRAISEDFLOORLEVELTO BEMINIMUMASDETERMINEDBY SITECONDITIONS

NICHE.DEPTH

TIGHTASPOSSIBLE.

SLIMCOLUMNADDED FOREXTRASUPPORT IFNEEDED.

LEFTSIDE CLOSETD RIGHTSIDE CLOSETD FRONTSIDE

RIGHTSIDE

RIGHTSIDE

SPEAKERSONPULLOUT DRAWERFORMAINTENANCE

CLOSETDOORTOSWINGAND LAYFLATAGAINSTWALL

SPEAKERSONPULLOUT DRAWERFORMAINTENANCE

CLOSETD
CLOSETC
CLOSETB
CLOSETA

SMOKEYGLASSDOORS

6&7A-3114&5

APPLIEDFABRICPANELONEXISTINGDOORS.

GRILLECOLORTBDBYAOR MTLWALLDETAILBELOW GRILLETOCONCEAL.

BATHROOM#3 (POWDERROOM)

BATHROOM#2(GUEST BATHROOM)

BATHROOM#1(HIS BATH)

BATHROOMFLOOR

SHOWERCEILING ST-8 HONED

SHOWERWALLS ST-8 HONED

VANITYCLADDING ST-8 HONED

BATHROOMFLOOR ST-1 HONED

SHOWERFLOOR ST-1 HONED

VANITYCOUNTERTOP

SHOWERWALLS ST-4 HONED

BATHROOMWALLS ST-4 HONED

SHOWERWALLS ST-3 HONED

VANITYCOUNTERTOP ST-3 HONED ANTI-ETCH

PRIMARYBATHROOM (HERBATH) BATHROOMFLOOR ST-3 HONED

VANITYCOUNTERTOP ST-3 HONED

DROPCEILING EXISTINGSTRUCTURE.

EXTENDWALLFINISHTO CONCEALPOCKETBEHIND. DROPCEILING EXISTINGSTRUCTURE. ALIGN ALIGN

4"WPOCKETFORDRAPERY RUNSTRAIGHTACROSSBAY WINDOWS.

EXTENDWALLFINISHTO CONCEALPOCKETBEHIND.

4"WPOCKETFORDRAPERY RUNSTRAIGHTACROSSBAY WINDOWS.

VARIESSEESCHED

ROUTEDPATTERN, PAINTED,SINGLESWING MDFDOOR. FLATONINSIDE.

SEESCHEDULEFORSIZE ANDFINISH.

ROUTEDPATTERN,PAINTED, SINGLESWINGMDFDOOR. WOODPATTERNONINSIDE. SEESCHEDULEFORSIZE ANDFINISH.

DOORELEVATIONS

TYPE'C'

ROUTEDPATTERN,PAINTED, POCKETMDFDOOR. FLATONINSIDE. SEESCHEDULEFORSIZE ANDFINISH. TYPE'B'

WOODBLOCKINGS

WALLTILE/SLABAS SPECIFIED

1"FABRICWRAPPED PLYWOODASSPECIFIED

5/8"TYPE'X'GYPBD BOTHSIDES(TYP)

WOODBLOCKINGS

WALLTILE/SLABAS SPECIFIED

WALLFINISHAS SPECIFIED

5/8"TYPE'X' GYPBDBOTH SIDES(TYP)

1"FABRICWRAPPEDPLYWOOD ASSPECIFIED

METALSTUDFRAMING WITHWOODSTIFFENER HAFELEHAWAJUNIOR80/Z TRACKSELFCLOSING MECH.SOFTMOVE80,WITH FLOORMOUNTEDDOOR GUIDES

5/8"TYPE'X'GYPBDBOTH SIDES(TYP) WOODBLOCKINGS

WALLSLABASSPECIFIED

SCHLUTERTRIM@SLAB EDGE

DOORDETAILSASPER SCHEDULE.

WALLTILE/SLABASSPECIFIED

5/8"TYPE'X'GYPBDBOTH SIDES(TYP)

METALSTUDFRAMING WITHWOODSTIFFENER

WALLFINISHASSPECIFIED

WOODBLOCKINGS

HAFELEHAWAJUNIOR80/Z TRACKSELFCLOSING MECH.SOFTMOVE80,WITH FLOORMOUNTEDDOOR GUIDES

DOORCASINGAS SPECIFIED

DOORDETAILSASPER SCHEDULE.

5/8"TYPE'X'GYPBDBOTH SIDES(TYP) METALSTUDFRAMING WITHWOODSTIFFENER

DOORCASINGAS SPECIFIED

DOORDETAILSASPER SCHEDULE. PROVIDEINSULATION(TYP) WALLFINISHASSPECIFIED 1"FABRICWRAPPED PLYWOODASSPECIFIED

5/8"TYPE'X'GYPBD BOTHSIDES(TYP) METALSTUDFRAMING WITHWOODSTIFFENER

WALLFINISHASSPECIFIED

DOORCASINGAS SPECIFIED

DOORDETAILSASPER SCHEDULE. 1"FABRICWRAPPED PLYWOODASSPECIFIED

NOTES: FRONTLEGSARESTRAIGHTANDTAPERED. BACKLEGSARECURVEDANDTAPERED. CENTERBACKLEGENDSATSEATHEIGHT.SIDE BACKLEGSEXTENDINTOTHEBACKSUPPORT

BATHROOMFLOOR RAISEDTO ACCOMMODATE

OWNER

ChrisKilgore Owner kilgore2014@gmail.com 215West78thStreet,Apt#1A,NewYorkNY,10024

RaquelTripp Owner rmatripp@gmail.com

MANAGEMENT FirstServiceResidentialEvelynStanczak PropertyManager evelyn.stanczak@fsresidential.com(212)851-8510 575FifthAvenue,NewYork,NY,10017

BUILDINGARCHITECT

ARCHITECTURE ArchetypeArchitecture

INTERIORDESIGNER

EXPEDITER NexusConsultingGroup NYC,Inc.

NatalieBeskrownyj AssistantPropertyManager natalie.beskrownyj@fsresidential.com(212)634-5493

Benny Superintendant (646)379-4900

AlanBerman,ArchitectA.O.R. Aberman@archetype-ny.com (212)580-6087 x101 2162Broadway,2ndFloor,NewYork,NY,10024

OmarKhalifa ProjectManager OKhalifa@archetype-ny.com x120

LaraSteiner ProjectManager LSteiner@archetype-ny.com x109

JimmyGhandi jimmy@nexusconsultingnyc.com (212)242-4926 x5 1PierrepointPlaza,12thFl,Brooklyn,NY11201

JacquelineMulinelli jacqueline@nexusconsultingnyc.com x4

ABERMAN@ARCHETYPE-NY.COM

COMMONABBREVIATIONS:

MASONRYOPENING MECHANICAL MEMBRANE MINIMUM MOLD&MOISTURERESISTANT METAL

NOTINCONTRACT NOMINAL NOTTOSCALE ONCENTER PRE-CASTCONCRETE PLUMBING PLYWOOD PRESSURETREATED PAINTED RUBBER

REFLECTEDCEILINGPLAN ROOFDRAIN REQUIRED ROOM ROUGHMASONRYOPENING SIMILAR

SEEMECHANICALDRAWINGS SLABONGRADE

SPECIFIEDORSPECIFICATION SPEAKER STAINLESSSTEEL

SEESTRUCTURALDRAWINGS

SOUNDTRANSMISSIONCOEFFICIENT STEEL

STRUCTUREORSTRUCTURAL TONGUEANDGROOVE

THERMOSTAT TELEPHONE TOILET TOPOF

TOPOFCONCRETE TOPOFSTEEL TOPOFWALL

TOILETPAPERDISPENSER

TELEPHONE/DATA

TYPICAL

UNLESSNOTEDOTHERWISE VERIFYINFIELD WITH WOOD WATERRESISTANTBARRIER

PLUMBINGTOBESUBMITTEDONSEPARATEDOBAPPLICATION

PLOTPLAN-NOTTOSCALE

CONTROLLEDINSPECTIONSREQUIREDFOR: PROGRESSINSPECTIONS: []FINALINSPECTION(DIRECTIVE14) []ENERGYCODECOMPLIANCE

ENERGYCODEINSPECTION: []LIGHTINGINDWELLINGUNITS. []LIGHTINGCONTROLS. INSPECTIONS

THISPROPERTYISNOTINA LANDMARKSDISTRICT

PROJECTFILEDUNDERNYC1968BUILDINGCODE

PROJECTINFORMATION:

215WEST78THST,APT.#1A NEWYORK,NY10024

EXISTINGHEIGHTSANDSETBACKSTOREMAIN.NOADDITIONAL BUILDINGAREAWILLBECONSTRUCTED.

BOROUGH: MANHATTAN BLOCK: 1170 LOT: 23 BIN: 1030906

MAPNO: 5D ZONING: R8B

COMMUNITYBOARD: 107

COMMERCIALOVERLAY: NONE

CONSTRUCTIONCLASS: CLASS1(1938CODE) FIREPROOFSTRUCTURE

OCCUPANCYCLASS: RESIDENTIAL(1938CODE)

MULTIPLEDWELLING

CLASSIFICATION: NL HEIGHT: 100 STORIES: 10

DWELLINGUNITES: 38

JOBDESCRIPTION:

ARCHITECTURALANDPLUMBING WORKFORINTERIORAPARTMENT RENOVATIONS.

NOCHANGEINUSE,EGRESSOROCCUPANCY

PROPERTYISNOTONS.F.H.A. (SPECIALFLOODHAZARDAREA)

1107.2.3.4COOKTOPSANDOVENS: COOKTOPSANDOVENSSHALLCOMPLYWITHSECTIONS1003.12.5.4AND1003.12.5.5OFICC A117.1,RESPECTIVELY.HOWEVER,OVENCONTROLSSHALLNOTBEREQUIREDTOBE LOCATEDONEITHERSIDEOFTHEOVENDOOR,PROVIDEDSUCHCONTROLSCOMPLYWITH SECTION1003.12.5.5.4OFICCA117.1.WHEREDOUBLEOVENSAREPROVIDED,ATLEASTONE OVENINTERIORANDITSCONTROLSSHALLCOMPLYWITHSECTION309.3(HEIGHT)OFICC A117.1.

1107.2.3.5KITCHENANDKITCHENETTESTORAGE: KITCHENSTORAGE,KITCHENCABINETS,DRAWERS,ANDSHELFSTORAGEAREAS,WITHIN KITCHENANDKITCHENETTESTHATAREREQUIREDTOCOMPLYWITHSECTION1003.12OFICC A117.1PURSUANTTOSECTION1107.2.3,EXCEPTOVERHEADCABINETS,SHALLCOMPLY WITHSECTION905(STORAGEFACILITIES)OFICCA117.1.INADDITION,ATLEASTONE STORAGESHELFORCABINET,MOUNTEDABOVEWORKCOUNTERSAT48INCHES(1219MM) MAXIMUMABOVE

EXCEPTION:WHERETHESTORAGESHELFORCABINETISNOTPROVIDEDINACCORDANCE WITHTHISSECTION,THEOWNERSHALLINSTALLSUCHSTORAGESHELFORCABINETIN COMPLIANCEWITHTHISSECTIONATTHETIMEPERSONWITHPHYSICALDISABILITIES TAKESOCCUPANCYOFTHEUNIT,ORWITHIN10DAYSOFTHEDATETHEREQUESTISMADE BYAPERSONWITHPHYSICALDISABILITIES,WHICHEVERISLATER,ATTHEOWNER'S EXPENSE.

1004.12KITCHENSANDKITCHENETTES: KITCHENSANDKITCHENETTESSHALLCOMPLYWITHSECTION1004.12.1004.12.1 CLEARANCE.CLEARANCECOMPLYINGWITHSECTION1004.12.1SHALLBEPROVIDED.

1004.12.1.1MINIMUMCLEARANCE: CLEARANCEBETWEENALLOPPOSINGBASECABINETS,COUNTERTOPS,APPLIANCES,OR WALLSWITHINKITCHENWORKAREASSHALLBE40INCHES(1015MM)MINIMUM. 1004.12.1.2U-SHAPEDKITCHENS.INKITCHENSWITHCOUNTERS,APPLIANCES,ORCABINETS ONTHREECONTIGUOUSSIDES,CLEARANCEBETWEENALLOPPOSINGBASECABINETS, COUNTERTOPS,APPLIANCES,ORWALLSWITHINKITCHENWORKAREASSHALLBE60INCHES (1525MM)MINIMUM.

1004.12.2CLEARFLOORSPACE: CLEARFLOORSPACEATAPPLIANCESSHALLCOMPLYWITHSECTIONS1004.12.2AND305.3. 1004.12.2.1SINK.ACLEARFLOORSPACE,POSITIONEDFORAPARALLELAPPROACHTOTHE SINK,SHALLBEPROVIDED.THECLEARFLOORSPACESHALLBECENTEREDONTHESINK BOWL.EXCEPTION:ASINKWITHAFORWARDAPPROACHCOMPLYINGWITHSECTION 1003.12.4.1.

1004.12.2.2DISHWASHER: ACLEARFLOORSPACE,POSITIONEDFORAPARALLELORFORWARDAPPROACHTOTHE DISHWASHER,SHALLBEPROVIDED.THEDISHWASHERDOORINTHEOPENPOSITIONSHALL

UNDERSIDEOF STRUCTUREABOVE.

7/8"FURRINGCHANNEL@16"OC

5/8"GYPSUMBOARDCEILING-PRIMED&PAINTED

SECTION

PLAN

ACCESSIBILITYNOTES:2014BCARTICLE11ACCESSIBILITY.ANSIA117.12009. 1107.2.2TYPEB+NYCUNITTOILETANDBATHINGROOMS WHERETOILETANDBATHINGROOMSAREPROVIDEDINTHETYPEB+NYCDWELLING UNITORSLEEPINGUNIT,ALLSUCHTOILETANDBATHINGROOMSSHALLCOMPLYWITH APPENDIXP.

EXCEPTIONFORTYPEATOILETANDBATHINGROOM: 1.0WHEREATLEASTONETOILETANDBATHINGROOMINTHETYPEB+NYC DWELLINGUNITORSLEEPINGUNITISCONSTRUCTEDINACCORDANCEWITHTHE TYPEATOILETANDBATHING FACILITIES REQUIREMENTSOFSECTION1003.11 (TOILETAND BATHINGFACILITIES),INCLUDINGSECTION1003.3.2(TURNING SPACE),OFICCA117.1ANDISINCOMPLIANCEWITHTHEFOLLOWING:

1.1ATLEASTONELAVATORY,ONEWATERCLOSETANDEITHERABATHTUBOR SHOWERWITHINSUCHTOILETORBATHINGFACILITYSHALLCOMPLY WITH  SECTION1003.11OFICCA117.1.SUCHTOILETANDBATHINGFIXTURES  SHALLBEINASINGLETOILETORBATHINGAREA,SUCHTHATTRAVEL BETWEENFIXTURESDOESNOTREQUIRETRAVELBEYONDTHEAREAINWHICH THEFIXTURESOFSUCHTOILETORBATHINGROOMARELOCATED.

1.2TOILETPAPERDISPENSERSWITHINSUCHROOMSSHALLCOMPLYWITH SECTION604.7(DISPENSERS)OFICCA117.1.

1.3MEDICINECABINETS,IFPROVIDED,MUSTINCLUDEASTORAGESHELFNO HIGHERTHAN44INCHES(1118MM)ABOVETHEFLOOR.

2.0WHEREATLEASTONETOILETANDBATHINGROOMCOMPLYINGWITHSECTIONS 1003.11AND1002.3.2OFICCA117.1ISPROVIDEDWITHINTHETYPEB+NYC DWELLINGUNITORSLEEPINGUNITINACCORDANCEWITHITEM1OFTHIS EXCEPTION,OTHERTOILETANDBATHINGROOMSINTHESAMEUNITSHALLBE REQUIREDTOCOMPLYONLYWITHSECTIONS 1004.3(ACCESSIBLEROUTE), 1004.4(WALKINGSURFACES),1004.5.2(USERPASSAGEDOORWAYS),1004.9 (OPERABLE PARTS)AND1004.11.1(GRABBARANDSHOWERSEAT REINFORCEMENT)OFICCA117.1.DOORSANDDOORWAYSTOSUCHTOILETAND BATHINGROOMSSHALLBESUBJECTTOSECTION1107.2.1,EXCEPTION5.

5/8"TYPE'X'GYPSUM BOARD-PRIMED& PAINTED

EXISTING DEMISINGWALL TOREMAIN

5/8"GYPSUMBOARD@BOTHSIDES-PRIMED& PAINTED

3-5/8"18GAUGEMETALSTUDS@16"O.C.

SOUNDATTENUATIONBATT INSULATIONBETWEENMETALSTUDS SEALANTATPERIMETER,TYP.

BASEASSCHEDULED

3-5/8"x18GAUGEMETALSTUDS@16"O.C.

5/8"GYPSUMBOARD @BOTHSIDES-PRIMED&PAINTED

SOUNDATTENUATIONBATTINSULATION BETWEENMETALSTUDS

A.GENERALDRYWALLPARTITION

SECTION

VARIES18GAUGEMETAL STUDS@16"O.C.

EXISTINGDEMISINGWALL

SOUNDATTENUATIONBATTINSULATIONBETWEEN METALSTUDS

3-5/8"x18GAUGEMETALSTUDS@16"O.C.

5/8"TYPE'X'GYPSUMBOARD-PRIMED&PAINTED

B.INTERIORWALLFURRING

3-1/2"METALSTUD

SOUND ATTENUATION BATTINSULATION PLAN B2

NEWFULLHEIGHTPARTITION 16GAUGEMETALSTUDS@16"O.C.WITHONELAYEROF5/8"TYPEXGYPSUMWALLBOARDONEACHSIDE,WITHSOUNDATTENUATION BATTINSULATIONBETWEENSTUDSUPTOCEILING. A1 NEWFULLHEIGHTPARTITIONFORWETAREAS: 3-1/2"16GAUGEMETALWALLSTUDS@16"O.C.WITHONELAYERTYPEXGYPSUMWALLBOARDONNON-WETSIDEANDONELAYER OFMOISTURERESISTANTCEMENTBOARDONWETSIDEFROMFLOORTOUNDERSIDEOFCEILINGABOVE.PROVIDEWOODBLOCKING TOSUPPORTCABINETRYANDBATHROOMACCESSORIES.

NEWFULLHEIGHTFURREDPARTITION "16GAUGEMETALSTUDS@16"O.C.WITHONELAYEROF5/8"TYPEXGYPSUMWALLBOARD,WITHSOUNDATTENUATIONBATT INSULATIONBETWEENSTUDSUPTOCEILING.

5MMSOUNDATTENUATION(TYP.) MINSTC/IIC62RATING

NEWWOODFLOORASSPECIFIED

PLYWOODUNERLAYMENT

SADDLEASSPECIFIED

FLOORTILESASSPECIFIED

MUDSETASREQUIREDFORFLOOR LEVELING.

5MMSOUNDATTENUATION(TYP.) MINSTC/IIC62RATING

CONTINUOUSKEMPER2KPUR WATERPROOFINGMEMBRANE. WATERPROOFINGSHALLBETURNEDUP ALONGSTEELANGLEAND12"ATALLWALLS INWETAREAS.

STEELANGLE

SOFFITDETAIL(Typical):

RAMSETPIN#SDC125C27CALIBER

EXISTINGUNDERSIDEOFCONCRETE CEILING

HILTIEYELET

EXISTINGUNDERSLABPLASTERCEILING

DIA.GALV.STEELPENCIL

ROD4'-0"O.C.MAX

2CARRYINGCHANNEL(BLACKIRON) .475#/LF4'-0"O.C.MAX.

GAT#131-68-5M

CADDYFASTENER

GAT#2815L

2FURRINGCHANNELCLIP

8METALFURRINGCHANNEL

2'-0"O.C.SCREWEDTOEDGEOFBLACKIRON 8SHEETROCK

XMINCONTINUOUS BLOCKINGCUTINTOSTUD

COVERPLATE (3)SCREWS 34TOCENTERLINEOF BLOCKINGTOFLOOR

MOUNTINGPLATE

WIC: -REMOVECLOSETDOORS,CLOSETWALLS,AND LIGHTS. -REMOVEEXISTINGDOORSASINDICATED. -EXISTINGRISERSTOREMAIN.PROTECTATALL TIMESDURINGDEMOLITION.REMOVEANY SURROUNDINGSHEETROCKORPLASTERWORK.

PRIMARYBEDROOM:

-REMOVEEXISTINGCEILINGLIGHT.

-REMOVEEXISTINGWALLSASINDICATED. -REMOVEEXISTINGDOORSASINDICATED.

HALFBATH:

-REMOVEEXISTINGTOILET.CAPANDRETURN EXISTINGPLUMBINGLINESBACKTORISER

NOTE: 1.EXISTINGCONDITIONSBASEDONSITEVISIT. PROBEASREQUIREDTOCONFIRMTHAT REMOVALDOESNOTAFFECTSTRUCTURAL, RISER,ORMECHANICALSYSTEMS.

2.NOCHIPPINGORCHANNELINGOFTHE EXISTINGBUILDINGSTRUCTUREISPERMITTED ATANYLOCATION.

GENERALREMOVALNOTES:

BATHROOM:

-EXISTINGTUBAPRONTOBEREMOVED.ALLTUB FIXTURESTOBEREMOVED.TUBTOREMAININ EXISTINGLOCATION.NOCHANGETODRAINAGE.

-EXISTINGFINISHESTOONLYBEREMOVED WHEREINDICATED. -PROTECTALLBATHROOMFIXTURESDURING DEMOLITION.

7.ANYEXISTINGUTILITYSERVICESTOBEREMOVED,

WALLSPRIORTOREMOVAL.PROVIDEALLNECESSARY SHORING,BRACING,ANDSUPPORTTOPREVENT MOVEMENT,SETTLEMENT,ORCOLLAPSEOF STRUCTUREORELEMENTTOBEDEMOLISHED,AND ADJACENTSTRUCTUREORELEMENTSHOWNTO REMAIN.

13.IFSOMETHINGINDICATEDONTHEPLANOR DISCOVEREDINTHEFIELDISNOTSPECIFICALLY IDENTIFIEDTOBEREMOVEDORTOREMAINONTHE PLANS,CONTRACTORSHALLREQUESTDIRECTION FROMARCHETYPEPRIORTOREMOVAL.

14.G.C.ISRESPONSIBLEFORTHETEMPORARYSHORING DESIGN.SUBMITDETAILSANDDESIGNCALCULATIONS BEARINGTHESEALOFALICENSEDPROFESSIONALOR STRUCTURALENGINEER'SREVIEWBEFORE CONSTRUCTIONOFSHORING.

15.SAFETYZONE:SAFETYZONESHALLBEPROVIDED AROUNDALLWORKAREASTOPREVENTPERSONS OTHERTHANWORKERSFROMENTERINGSUCHZONE. WHEREWORKOCCURSONTHEEXTERIOROFA BUILDING,SUCHZONESHALLBEAPPROVEDBYTHE COMMISSIONERPRIORTOTHECOMMENCEMENTOF WORK.

16.SEQUENCE:ANYSTRUCTURALMEMBERTHATISBEING DISMEMBEREDSHALLNOTSUPPORTANYLOADOTHER THANITSOWNWEIGHT.NOWALL,CHIMNEY,OR OTHERSTRUCTURALPARTSHALLBELEFTINSUCH CONDITIONTHATITMAYCOLLAPSEORBETOPPLEDBY WIND,VIBRATIONORANYOTHERCAUSE.THEMETHOD OFREMOVALOFANYSTRUCTURALMEMBERSHALL

KITCHEN:

-REMOVEEXISTINGCOMBINATION WASHER-DRYER.

-REMOVEDISHWASHER,TOBERELOCATEDIN NEWLOCATION,SEECONSTRUCTIONPLANFOR LOCATION.

-REMOVEEXISTINGPENINSULACOUNTERTOP. KITCHENCABINETRYTOREMAIN.

ENTIREAPARTMENT:

-REMOVEEXISTINGELECTRICALOUTLETS THROUGHOUTENTIREAPARTMENTASREQUIRED, TOBEREPLACEWITHNEWPERCODE.

-REMOVEEXISTINGLIGHTFIXTURES THROUGHOUTAPARTMENTASINDICATED.TOBE REPLACEWITHNEW.SEERCPPLANFOR LOCATION.

HALLWAYFOYER:

-REMOVEEXISTINGWOODFLOOR. -REMOVEEXISTINGBASEBOARDASNEEDED.

BEDROOM2:

-REMOVEEXISTINGWOODENWINDOWSCREENS. -REMOVEEXISTINGSCONCES.

BEDROOMDINING:

-REMOVEEXISTINGWOODENWINDOWSCREENS. -REMOVEEXISTINGSCONCES.

ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMS ORTENANTSSHALLREMAINTHROUGHOUT(PLUMBING,ELECTRICALAND DOORBELLRISERS).

ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,PROTECTDURING DEMOLITIONANDCONSTRUCTION.(ALLLOCATIONSOFPLUMBINGRISERSSHOWNON PLANSAREASSUMED,NOTVISIBLEATTIMEOFFIELDSURVEY.)VERIFYALLEXISTING SHUTOFF/CHECKVALVESLOCATIONSINTHEENTIREAPARTMENT.COORDINATEBRANCH REPLACEMENT,REPAIR&RELOCATIONWITHBLDGSUPER.REPLACEALLACCESS PANELS(MIN.12"X12")ATALLPLUMBINGRISERLOCATIONSTHROUGHOUTPER BUILDINGREQUIREMENTS.COORDINATEWORKWITHBLDGPLUMBER&BLDG.SUPER.

IFSOMETHINGINDICATEDONTHEPLANORDISCOVEREDINTHEFIELDISNOT SPECIFICALLYIDENTIFIEDTOBEREMOVEDORTOREMAINONTHEPLANS,CONTRACTOR SHALLREQUESTDIRECTIONFROMARCHETYPEPRIORTOREMOVAL.

MAINTAINFIRERATINGOFSHAFTWALLSANDCOLUMNORBEAMENCLOSURES. PROTECTATALLTIMESDURINGCONSTRUCTION.RESTOREASNECESSARY.

EXISTINGCONCRETECEILINGANDFLOORSTOREMAIN.NOCHANNELINGOFEXISTING STRUCTURALCONCRETEALLOWED.CHIPDOWNNON-STRUCTURALCONCRETETOPPING INFUTUREKITCHENSOFLOORSCANBELEVEL.

ALLEXISTINGWINDOWSTOREMAIN.G.C.TOPROTECTATALLTIMESDURING DEMOLITION.

REMOVEEXISTINGSWITCHES,OUTLETSANDELECTRICALLINESINPARTITIONSTOBE DEMOLISHEDANDTHROUGHASINDICATED.SEEELECTRICALPLANFORNEWLAYOUT. REMOVEALLEXISTINGILLEGALSURFACEMOUNTEDCONDUITOREXPOSEDELECTRICAL LINESTHROUGHOUT

UPGRADEELECTRICALPANELSASNECESSARY.ALLWORKTOBEDONEBYALICENSED ELECTRICIAN.COORDINATEWORKWITHBUILDINGSUPERINTENDENTANDARCHETYPE PRIORTOJOBSTARTUP.CONTRACTORTOCONFIRMTHATEXISTINGLOADWILLBE ADEQUATEFORTHEPROPOSEDWORKANDNOTIFYARCHITECT.

REMOVEEXISTINGCLOSETINTERIORSYSTEMS,HANGINGPOLESAND/ORSHELVESIN ALLCLOSETS.PREPARECLOSETAREASTORECEIVENEWFINISHES.

BATHROOMPROTECTALLFINISHESTOREMAININEXISTINGBATHROOM.PROTECTALL BATHROOMFIXTURESTOREMAIN.

REMOVEINTERIORDOORSANDDOORFRAMESASNOTEDONDRAWINGS.REFERTODOOR SCHEDULEONSHEETA-300.00FORMOREINFORMATION.

EXISTINGORIGINALWOODFLOORSTOREMAINTHROUGHOUT.PROTECTATALLTIMES DURINGDEMOLITIONANDCONSTRUCTION.SALVAGEEXISTINGWOODFLOORFORPATCHING EXISTINGFLOORS.

2162Broadway,2ndFL

PHONE:212.580.6087

ABERMAN@ARCHETYPE-NY.COM

ALANBERMANRAAIA NYSLIC.036223

STRUCTURALENGINEER: MECHANICALENGINEER:

NOTDESTABILIZEREMAININGMEMBERS.ALL HANDLINGANDMOVEMENTOFMATERIALORDEBRIS SHALLBECONTROLLEDSUCHTHATITWILLNOT DEVELOPUNACCOUNTEDIMPACTLOADSONTHE STRUCTURE.

17.NOSTRUCTURALMEMBERSTOBEMODIFIEDINANY WAY

GRAPHICLEGEND: CONCRETEMASONRYUNIT(CMU)WALL

CONCRETECONSTRUCTION

EXISTINGBUILDINGSTRUCTURE,WALLSOR ELEMENTSTOREMAIN

EXISTINGINTERIORWALLSORELEMENTSTOBE REMOVED

NOTE:ALLWALLS&PARTITIONSBEINGREMOVEDARENOT LOADBEARING.

EXITINGCONDITIONSBASEDONSITEVISIT.PROBEASREQ'D TOCONFIRMTHATREMOVALDOESNOTAFFECTSTRUCTURAL, RISERS,ORMECHANICALSYSTEMS.

BATHROOM2: -NEWPOCKETDOORANDDOORFRAMEFORNEW BATHROOM -EXISTINGRISERSTOREMAIN.PROTECTATALL TIMESDURINGCONSTRUCTION.

-NEWWALLANDFLOORTILE.PATTERNTOBE CONFIRMEDBYCLIENT.

-NEWTOILET,NEWSINKVANITYINNEW LOCATION.SEESPECSSUPPLIEDBYCLIENT.

-EXISTINGTUBTOREMAININEXISTINGLOCATION. NEWTILEDAPRON.

PRIMARYBEDROOM:

2.ANYBREACHESINFIRE-RATEDSHAFTWALLS TOBEREPAIRED/REPLACEDATTHEENDOF EACHWORKDAY.

LAUNDRY:

-NEWSUPPLYANDRETURNLINEFORNEW, ELECTRIC,STACKED,VENTLESSWASHER/DRYER ININDICATEDLOCATION.REFERTOG-003FOR DETAILS.

BATHROOM: -EXISTINGTOILET&SHOWERFIXTURESTOREMAININ EXISTINGLOCATION.PROTECTATALLTIMESDURING CONSTRUCTION. -NEWVANITYANDSINK -ANYTILEDWALLSNOTPARTOFDEMOLITIONTOBE PROTECTEDDURINGCONSTRUCTION.NEWWALLTILETO MATCHEXISTINGATNEWWALL. -ADDGRILLATTOPOFFWALLFORPASSIVEVENTILATION

GENERALCONSTRUCTIONNOTES:

16.PROVIDENEWLATICRETE#9235WATERPROOFMEMBRANE&SOUNDMATTINGBELOW OVERENTIREKITCHENLAUNDRYANDBATHROOMAREAS,TURNEDUP12"ATWALLASPER DETAILSINSHEET#G-003.

17.SUPPLY&INSTALLALLCONSTRUCTIONMATERIALSINCLUDINGBUTNOTLIMITEDTOPAINT, SPACKLE,GLUE,FLOORINGCOMPOUNDS,GROUT,SWITCHES,OUTLETS,DIMMERS,CONDUIT AND/ORSPECIALWIRINGASREQUIRED.

PROTECTDURINGCONSTRUCTION.(ALLLOCATIONSOFPLUMBINGRISERSSHOWNON PLANSAREASSUMED,NOTVISIBLEATTIMEOFFIELDSURVEY).EXPLOREANDVERIFYRISER LOCATION,IFANYSPACECANBEGAINED. 27.PLUMBINGWORKSHALLBEDONEBYLICENSEDNYCPLUMBERWHOSHALLARRANGEFOR ANDOBTAINALLREQUIREDDOBPERMITS,INSPECTIONSANDSIGN-OFFS.ALLPLUMBING WORKSHALLCOMPLYWITHTHENYCPLUMBINGCODE.

18.SUPPLY&INSTALLNEWCUSTOMBASEMOLDINGS,PICTUREMOLDINGSANDDOORCASING MOLDINGSTHROUGHOUTENTIREAPARTMENTASSHOWNINPLANS.DYKESOREQUAL.

19.PROVIDENEWSHUT-OFFVALVES@FIXTURES&RISERS@ALLNEWPLUMBINGLOCATIONS. PROVIDEACCESSPANELSASREQUIRED. 20.WHERENEWPLUMBINGFIXTURESAREINSTALLEDORBRANCHPIPINGOTHERWISEEXPOSED (INCLUDINGSTEAM,VENT&DRAINLINES),THECONTRACTORSHALLREPLACEFROMTHE FIXTURETOTHEBUILDING'SRISERSANDSTACKS,ANDREPLACELOCALRISERSHUT-OFF VALVESASMAYBEREQUIRED.

21.GENERALCONTRACTORSHALLBERESPONSIBLETOFAMILIARIZEHIMSELFWITHTHE LOCATIONSOFALLWATERSHUT-OFFVALVESCONTROLLINGTHEWATERINTHELOCATION OFWORK.GCSHALLDELEGATESOMEONEONSITEORHAVEINFORMATIONREADILY AVAILABLETHATWILLALLOWFORTHEIMMEDIATEWATERSHUTOFFSYSTEMSSHOULDAN UNFORESEENWATERFLOWNEEDTOBECONTAINED.

22.NOCHANNELINGOFANYSTRUCTURALSLAB,DEMISINGWALLSANDEXTERIORWALLSOR PIPECHASE/SHAFTENCLOSUREWALLSWILLBEPERMITTEDDURINGTHECOURSEOFANY WORK.

23.NOOFFSETOFRISERS(PLUMBING,GAS,ETC)WILLBEPERMITTED.

24.ALLPLUMBINGWORKWILLBEPERFORMEDBYANEWYORKCITYLICENSEDPLUMBERAND ALLELECTRICALWORKWILLBEPERFORMEDBYANEWYORKCITYLICENSEDELECTRICIAN. ALLREQUIREDPERMITSSHALLBEOBTAINED.

25.G.CSHALLCONFIRMANDBERESPONSIBLETHATAFTERWORKHASBEENCOMPLETEDALL THEEXISTINGANDNEWELECTRICALEQUIPMENTSANDFIXTURES,INCLUDINGBUTNOT LIMITEDTO(APPLIANCES,HVACUNITS,AVEQUIPMENTS,ETC.)ARECONNECTED, FUNCTIONINGANDWORKING.

26.ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSORTENANTS SHALLREMAINTHROUGHOUT.ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,

KITCHEN:

-NEWLINEFOREXISTINGDISHWASHERINNEW LOCATION.

-EXISTINGREFRIGERATOR,SINK,MICROWAVE& RANGETOREMAININEXISTINGLOCATIONS.TO BEPROTECTEDATALLTIMESDURING CONSTRUCTION.

-NEWCOUNTERTOPFORKITCHENISLAND.

ENTIREAPARTMENT:

-EXISTINGWALLSTOBEPATCHED.ENTIRE APARTMENTTOGETPLASTERANDPAINT.

-BASEBOARD&CROWNMOLDINGTHROUGHOUT ENTIREAPARTMENTTOREMAINUNLESS DISTURBED.NEWFINISHCARPENTRYTOMATCH EXISTING.

-ALLEXISTINGWINDOWSTOREMAIN.PROTECT ATALLTIMESDURINGCONSTRUCTION.

-SANDANDREPAINTEXISTINGWOODWINDOW SILLSANDINNERMOLDINGS.TYPICAL.

-NEWBARSTOBEINSTALLEDINSIDEALL WINDOWWELL.

HALLWAYFOYERLIVINGROOM:

-EXISTINGSTRUCTURALCOLUMNTOBEPROTECTEDAT ALLTIMESDURINGCONSTRUCTION.TOBEFINISHEDTO MATCHSURROUNDINGWALLS.

CONSTRUCTIONKEYNOTES

ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSOR TENANTSSHALLREMAINTHROUGHOUT(PLUMBING,ELECTRICAL,INTERCOMAND DOORBELLRISERS).PROTECTRISERSDURINGDEMOLITIONANDCONSTRUCTION. ALLLOCATIONSOFPLUMBINGRISERSSHOWNONPLANSAREASSUMED,NOT VISIBLEATTIMEOFFIELDSURVEY.

VERIFYALLEXISTINGSHUTOFF/CHECKVALVESLOCATIONSINTHEENTIRE APARTMENT.COORDINATEREPLACEMENT,REPAIR&RELOCATIONWITHSUPER. COORDINATEWORKWITHBUILDINGSUPERINTENDENT.

IFSOMETHINGINDICATEDONTHEPLANORDISCOVEREDINTHEFIELDISNOT SPECIFICALLYIDENTIFIEDTOBEREMOVEDORTOREMAINONTHEPLANS, CONTRACTORSHALLREQUESTDIRECTIONFROMARCHETYPEPRIORTOREMOVAL.

MAINTAINFIRERATINGOFSHAFTWALLSANDCOLUMNORBEAMENCLOSURES. PROTECTATALLTIMESDURINGCONSTRUCTION.RESTOREDAMAGEDAREAS.

A05

BATHROOMS:G.C.TOINSTALLALLNEWOWNERSUPPLIEDFIXTURESANDFINISHES SUCHASTOILET,SHOWERCONTROLS,FLOORSTANDINGVANITYUNITTOBE INSTALLEDBYG.C.,LAVATORY/SINK,DECKMOUNTEDFAUCET,RECESSEDMOUNTED MEDICINECABINET,CEILINGLIGHTFIXTURES&WALLSCONCES.INSTALLNEW OWNERSUPPLIEDFLOOR,WALLFIELDTILESANDALLOWNERSUPPLIED ACCESSORIES.SEESEPARATEMATERIALS,FIXTURES&FINISHESSPECIFICATIONS.

A06 SKIMCOATALLWALLSANDCEILINGSTHROUGHOUT.PATCHCRACKS,OPENINGS, IMPERFECTIONS,ETC.APPLYPRIMERAND(2)COATSOFPAINTTOALLWALLSAND MOLDINGSTHROUGHOUT.PROVIDEALLOWANCEFORFIVE(5)'BENJAMINMOORE' PAINTCOLORS.

SUPPLYANDINSTALLALLNEW1"THICK,SOLIDCOREPAINTGRADE(POPLAR) WOODDOORSANDFRAMES.INSTALLEDOWNERPROVIDEDANDHARDWARE.G.C. TOCOORDINATEWITHARCHETYPETHEHINGESANDHARDWAREBEFOREG.C. PURCHASETHEDOORS.WITHNEWHINGESTHROUGHOUT.INSTALLNEWOWNER SUPPLIEDDOORLEVERS&DOORSTOPSTHROUGHOUT.SUPPLYANDINSTALLNEW INTERIORDOORSASPERPLAN.

A08

BEDROOM2: -NEWBARSTOBEINSTALLEDINSIDEALLWINDOW WELL.

-NEWLIGHTFIXTURES.SEEA-800FORMORE INFORMATION

BEDROOMDINING:

-NEWBARSTOBEINSTALLEDINSIDEALLWINDOW WELL.

-NEWLIGHTFIXTURES.SEEA-800FORMORE INFORMATION

EXISTINGORIGINALWOODFLOORSTOREMAINTHROUGHOUT.PATCHANDREPAIR ANDFEATHERINNEWWOODFLOORINGANDREDOBORDERSWHEREWALLSHAVE BEENREMOVED.PROVIDEANDINSTALLNEWSHOEMOLDINGSWHEREBASEBOARD HAVEBEENREMOVED. FORAREASTORECEIVENEWWOODFLOORS:SUPPLYANDINSTALLNEWWOOD FLOORINGINSTRAIGHTRUNPATTERNMATCHEXISTINGINSIZE,SPECIESANDCOLOR. INSTALL3/4"PLYWOODSUBFLOORWITHSOUNDATTENUATION.SANDFLOORS THROUGHOUT,APPLY(2-3)NEWSTAINCOATSAND(2-3)POLY-URETHANECOATS (WATERBASEDONLY)MINIMUMUNTILFINALMATCHINGSTAINISACHIEVED.CLIENT TOAPPROVESTAINSAMPLESPRIORTOFINALAPPLICATION.PROVIDEANDAPPLY3 STAINSAMPLES,FORCLIENT'SAPPROVAL.

PHONE:212.580.6087

ABERMAN@ARCHETYPE-NY.COM

ALANBERMANRAAIA NYSLIC.036223

STRUCTURALENGINEER: MECHANICALENGINEER:

28.THEBUILDINGSTRUCTURE,INCLUDINGSTEELCOLUMNS,STEELBEAMSANDCONCRETE FLOORSLABSANDFIREPROOFINGATTACHEDTHERETO,SHALLNOTBEDISTURBEDINANY WAY.FLOORSLABSSHALLNOTBECHOPPED,CHANNELEDORCORED.THISINCLUDESTHE FLOORSURFACE(TOPOFSLAB)ANDTHECEILINGSURFACE(BOTTOMOFSLAB). FIREPROOFING,WHETHERFOUNDTOBEDAMAGEDORMISSINGORDAMAGEDDURING CONSTRUCTIONSHALLBEREPAIREDTOPROVIDETHEREQUIREDFIRE-RESISTANCERATINGS. 29.OPENINGS/GRILLESINTOVENTILATIONSHAFTSORPLUMBINGCHASESMUSTBESEALED WHILEWORKISBEINGDONESOTHATNODUST,DIRT,OROTHERTYPEOFNUISANCECAN AFFECTOTHERAPARTMENTSORCOMMONAREAS.

EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN EXISTINGINTERIORWALLSOR ELEMENTSTOBEREMOVED

PLUMBINGFIXTURETAGAPPLIANCE/EQUIPMENTTAGREFERTOSCHEDULE P-

REFERTOSCHEDULE

EXISTING(2)HOURRATEDWALL T THERMOSTAT(LUTRONOREQUAL) NEWCONSTRUCTION

GRAPHICLEGEND: DOORTAG-REFERTOSCHEDULE

SMOKE/CARBONMONOXIDEDETECTORASPER RS-1713/14ALSOTOCOMPLYWITHLL7/04

ELECTRICALPANEL

PARTITIONSCHEDULE:

ALLINTERIORPARTITIONS&FURRINGTOHAVEFULL HEIGHTSOUNDBATTS.QUIETROCKASNOTED.

NEWFULLHEIGHTPARTITIONPROVIDE2"OR316GAUGEMETALSTUDS@16"O.C. WITHONELAYEROF5/8"TYPEXGYPSUMWALLBOARDONEACHSIDE,WITHSOUND ATTENUATIONBATTINSULATIONBETWEENSTUDSUPTOCEILING. A A1 NEWFULLHEIGHTPARTITIONFORWETAREAS: 2OR31 216GAUGEMETALWALLSTUDS@16"O.C.WITHONELAYER8TYPEX GYPSUMWALLBOARDONNON-WETSIDEWITHSOUNDATTENUATIONBATTINSULATION BETWEENSTUDSUPTOCEILINGANDONELAYEROF5MOISTURERESISTANTCEMENT BOARDONWETSIDEFROMFLOORTOUNDERSIDEOFCEILINGABOVE.PROVIDEWOOD BLOCKINGTOSUPPORTCABINETRYANDBATHROOMACCESSORIES.

C NEWHRRATEDPARTITION:UL#U411 PROVIDE31/2"16GA.METALSTUDS@16"O.C.WITHTWO(2)LAYERSOF5 8TYPEX GYPSUMWALLBOARDONEACHSIDEW/SOUNDATTENUATIONBATTINSULATION BETWEENSTUDSUPTOCEILING. B NEWFURREDOUTWALL: 116GAUGEMETALWALLSTUDS@16"O.C.W/SOUNDATTENUATIONBATT INSULATIONUPTOCEILING.USE5/8"MOISTURERESISTANTGYPSUM/CEMENTBOARDON

NEWTILEAPRON TILEPATTERNN.I.C.CLIENTTO CONFIRMPATTERN

EXISTINGBATHTUBTOREMAIN

F.B.O.NEWWALLTILE LEPATTERNNCCLENT TOCONFIRMPATTERN

F.B.O.NEWTOILET

INTERIORSNOTES:

6.

FINISHDROPCEILING

F.B.O.NEWWALLTILE

TILEPATTERNN.I.C.

CLIENTTOCONFIRM PATTERN

NEWF.B.O.MIRRORED MEDICINECABINET NEWF.B.O.TOWELRACK CLIENTTOCONFIRMSIZE ANDLOCATION

F.B.O.NEWWALLTILE TLEPATTERNNCCLE TOCONFIRMPATTERN NEWPOCKETDOOR NEWFBOSNKANDVA

NCSTORAGEBYOTHE

NEWTILEAPRON

(EXISTINGBATHTUBTO REMAINBEHIND)

F.B.O.NEWTILE

TLEPATTERNNCCLE TOCONFIRMPATTERN

2162Broadway,2ndFL NEWYORK,NY10024

NEWGRILLFOR

F.B.O.NEWWALLTILE TLEPATTERNNCCLEN TOCONFIRMPATTERN

NEWTILEAPRON (EXISTINGBATHTUBTO REMAINBEHIND)

F.B.O.NEWTILE TLEPATTERNNCCLEN TOCONFIRMPATTERN

GCTOINSTALLALLF.B.O. PLUMBINGFIXTURES CLIENTTOCONFIRMSHOWER HEADTYPEANDACCESSORIES

NEWPARTITIONWALL

EXISTINGBATHTUBTOREMAIN

NEWTILEAPRON TILEPATTERNN.I.C.CLIENTTO CONFIRMPATTERN

F.B.O.NEWLIGHT FIXTURETYPEAND LOCATIONTOBE CONFIRMEDBY CLIENT

FINISHDROPCEILING ELEV.9'-0"V.I.F.

F.B.O.NEWWALLTILE

TILEPATTERNN.I.C.

CLIENTTOCONFIRM PATTERN

F.B.O.NEWMIRRORED MEDICINECABINET

F.B.O.NEWSINK, FAUCETANDVANITY

F.B.O.NEWTOILET

ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSORTENANTSSHALL REMAINTHROUGHOUT.ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,PROTECT DURINGCONSTRUCTION.ALLLOCATIONSOFPLUMBINGRISERSSHOWNONPLANSAREASSUMED, NOTVISIBLEATTIMEOFFIELDSURVEY.G.C.TOVERIFYACTUALLOCATIONONSITEDURING DEMOLITION.

G.C.TOINSTALLNEWSHOWERHEAD&CONTROLSONNEWROUGH-INS F.B.O.-FURNISHEDBYOWNER,INSTALLEDBYCONTRACTOR

G.C.TOSUPPLYANDAPPLY(2)COATSOFPAINTTOCEILINGANDWALLS.ALLOWFOR(2)BENJAMIN MOOREPAINTCOLORS.COORDINATEPAINTCOLORWITHOWNERS

G.C.TOINSTALLALLNEWOWNERSUPPLIEDFLOORTILES.PROVIDEWATERPROOFMEMBRANE OVERENTIREBATHROOMAREATURNEDUP12"ATWALLS.

G.C.TOINSTALLALLNEWOWNERSUPPLIEDACCENTTILES.

G.C.TOINSTALLNEWOWNERSUPPLIEDMARBLESADDLEATMOSTABOVEFINISHEDFLOOR.NEW BATHROOMFLOORTOMATCHHEIGHTOFNEWWOODFLOORINRESTOFAPARTMENT.PROVIDENEW SELFLEVELINGCONCRETEASREQUIRED.

G.C.TOINSTALLVANITYCABINETWITHOWNERSUPPLIEDLAVATORY/SINK,ANDFAUCETG.C.TO SUPPLYANDINSTALLPLYWOODWALLSUPPORTS.CONFIRMWITHCLIENTMATERIALS,FIXTURES& FINISHESSPECIFICATIONS

G.C.TOINSTALLNEWOWNERSUPPLIEDMEDICINECABINET.CONFIRMHEIGHTW/OWNER.CONFIRM FIXTUREANDFINISHESSPECSWITHOWNER.VERIFYAREABEHINDWALL.INSTALLPER MANUFACTURER'SRECOMMENDATIONS.PROVIDEADEQUATESUPPORTBEHINDWALLS& COORDINATEINSTALLATIONWITHVENDORANDARCHETYPE.

G.C.TOINSTALLNEWOWNERSUPPLIEDSHOWERHEAD,PLUMBINGFITTINGS,ANDCONTROLS.SEE SEPARATEFIXTUREANDFINISHESSPEC.CONFIRMSHOWERHEADANDHANDHELDSHOWERHEIGHT W/CLIENT.

G.C.TOINSTALLALLNEWOWNERSUPPLIEDACCESSORIESTHROUGHOUT.PROVIDEADEQUATE PLYWOODBLOCKINGWITHINWALLS.

G.C.TOSUPPLYANDINSTALLNEWGFCIELECTRICALOUTLETSWITHSTANDARDWHITESCREWLESS COVERPLATESTOCOMPLYWITHCURRENTNECELECTRICALCODES.

VERIFYEXISTINGSHUTOFFVALVESLOCATIONSTHROUGHOUTENTIREAPT.COORDINATEREPLACEMENT, REPAIR&RELOCATIONWITHSUPER.PROVIDE/REPLACERECESSEDACCESSPANELS,ASNEEDED.

G.C.TOINSTALLNEWOWNERSUPPLIEDSURFACEMOUNTEDLIGHTFIXTURESANDWALLSCONCES.

G.C.TOPROVIDEANDINSTALLNEWLUTRONSWITCHESONDIMMERSWITHNEWSNAPONTYPE WHITECOVERPLATES.SEEPLANSANDELEVATIONSFORSPECIFICHEIGHTS.

3.MANUFACTURER:'TRUSTILE'ORAPPROVEDEQUAL.

NOTE:

1.THISDRAWINGSHALLBEREADINCONJUNCTIONWITHARCHETYPE'SAND

2.FORDOORSWING(LEFTORRIGHTHINGED)SEEFLOORPLANSHEETA-001.

3.VERIFYINFIELDFOREXACT/ACCURATEDIMENSIONS(HEIGHTANDWIDTH)WHEN PERTAININGTOALLNEWANDEXISTINGOPENING.

DOORTYPES:

GENERALFINISHNOTES:

1.ALLWORKSHALLBEINACCORDANCEWITHALLSTATEANDLOCALCODES.

2.COORDINATE&SUPERVISEALLTRADESANDPROVIDETHEDESIGNATEDCLEARANCESSHOWNONTHESEDOCUMENTS.G.C.SHALLINFORMARCHETYPEPRIORTOPROCEEDING WITHWORKTHATDIFFERSFROMTHEDESIGNINTENT.

3.ALLDIMENSIONSARETOBETAKENFROMFACEOFFINISHEDGYP.BOARDUNLESSOTHERWISEINDICATED.

4.PREPAREALLSURFACESFORFINISHESPERMANUFACTURERSPECIFICATIONS.

5.SAND&APPLY(2)COATSOFCLEARPOLYURETHANETONEWWOODFLOORSTHROUGHOUTENTIREAPARTMENT.FLOORSTOBEPROTECTEDDURINGCONSTRUCTIONAS REQUIRED.USEWATERBASEDPOLYURETHANEONLY,ASREQUIREDBYBUILDING.

6.SEALALLPENETRATIONSTHROUGHALLFLOORS,WALLS&DOORS&ALLREDUCINGSTRIPSWHERECHANGESINFLOORFINISHESOCCUR.SUBMITSAMPLESFORAPPROVALTO ARCHETYPE.

7.SUPPLYALLCONSTRUCTIONMATERIALSINCLUDINGBUTNOTLIMITEDTOPAINT,SPACKLE,GLUE,FLOORINGCOMPOUNDS,GROUT,SWITCHES,CONDUITAND/ORSPECIALWIRING ASREQUIRED.

8.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTINGFLOORSANDWALLSTHROUGHOUT.

9.FLASH,PATCHANDLEVELTHEFLOORSASREQUIREDFORNEWFLOORFINISHES.ALLFLOORFINISHESMUSTBEATTHESAMEFINISHELEVATIONUNLESSNOTEDOTHERWISE. NOTIFYARCHETYPEIFTHISCANNOTBEACHIEVEDSOTHATANYDETAILSCANBEMODIFIEDACCORDINGLY.

10.FLOORINGTOEXTENDUNDERMILLWORKANDAPPLIANCES(TYPICAL).

11.NSTALLNEWOWNERSUPPLIEDSTONE/TILEFLOOR.PROVIDE&INSTALLNEWSOUNDPROOFUNDERLAYMENTASREQUIREDBYBUILDINGMANAGEMENT.PROVIDEANDINSTALL NEWWATERPROOFINGMEMBRANEOVERENTIREFLOORAREATURNEDUP6"ATWALLS,REFERTOSHEETG-003.

12.GCTOPROVIDE&INSTALLNEWWOODSADDLES.NEWSTONESADDLESPROVIDEDBYOWNER,INSTALLEDBYCONTRACTOR.METALTRANSITIONSTRIPSASNOTED.

13.CONTRACTORTOSUPPLYANDINSTALLNEWPLYWOODSUB-FLOORSATALLAREASTORECEIVENEWFINISHFLOOR.PROVIDENEWSOUNDUNDERLAYMENTREFILLFLOORSWITH FLYASHASREQUIRED.CONFIRMWITHARCHETYPETHATALLFLOORSCANBEMADETOTHESAMELEVELPRIORTOINSTALLATION.

14.CONTRACTORTOFEATHERINNEWWOODFLOORINGTOMATCHWHEREWALLSHAVEBEENREMOVED.LEVELWITHEXISTINGFLOOR&SPOTSTAINTOMATCHEXISTING

NOTES:

1.THISDRAWINGSHALLBEREADINCONJUNCTIONWITHARCHETYPE'SANDCLIENT'SMATERIALS,FIXTURESANDFINISHES SPECIFICATIONS,DOORHARDWAREANDALLDETAILEDPLANSANDDRAWINGS.

GENERALDOORNOTES:

1.PROVIDE&INSTALLNEWSOLIDCORE"MEDIUMHARDWOOD"PAINTGRADEDOORSANDSTANDARD2"DOORCASINGSTHROUGHOUT ASSHOWNINPLANS&ASPERDOORSCHEDULEDOORSSHALLBEFREEOFKNOTS.

2.PROVIDE&INSTALLNEWHINGESTHROUGHOUT.(QUANTITY:3PERDOOR)

3.ALLNEWDOORSTOBESANDEDANDPAINTED/STAINEDTHOROUGHLY.COLOR&FINISHTOBEDETERMINEDATLATERDATE.

4.DOORSSHALLBEFREEOFKNOTS.

5.INSTALLALLOWNERSUPPLIEDWALLORFLOORDOORSTOPSTHROUGHOUT.

6.DOORMANUFACTURERTOBETRUSTILEORAPPROVEDEQUAL.

7.2.PURCHASEANDINSTALLALLITEMSINTHEDOORSCHEDULEANDDOORTYPES&DETAILEDJAMBANDHEADSECTION.VERIFYIN FIELDFOREXACT/ACCURATEDIMENSIONSWHENPERTAININGTOANEXISTINGOPENING.

8.INSTALLNEWHARDWARETHROUGHOUT.

9.PROVIDEANDINSTALLNEWSTONESADDLESTHROUGHOUTASINDICATEDINSCHEDULEABOVE.STONESADDLESSHALLBE STRAIGHT-CUTWITH4BEVELATBOTHSIDES.STONESHALLBEMARBLEOREQUAL,SUBMITSAMPLETOARCHETYPEFORAPPROVAL.

10.DOORS:GENERALSHALLMEETTHEREQUIREMENTSOFTHEBUILDINGCODE&CURRENTEDITIONOFTHELIFESAFETYCODE.

NOTES:

1.THISDRAWINGSHALLBEREADINCONJUNCTIONWITHARCHETYPE'SANDCLIENT'SMATERIALS,FIXTURESANDFINISHES SPECIFICATIONS,DOORHARDWAREANDALLDETAILEDPLANSANDDRAWINGS.

2.VERIFYINFIELDFOREXACT/ACCURATEDIMENSIONS(HEIGHTANDWIDTH)WHENPERTAININGTOALLNEWANDEXISTING OPENINGS.

HARDWARENOTES:

1.PROVIDE&INSTALLNEWHARDWARE. MANUFACTURER:TBD FINISH: TBD.

ABERMAN@ARCHETYPE-NY.COM

STRUCTURALENGINEER: MECHANICALENGINEER:

BATHROOM: -ANYNEWBATHROOMOUTLETSTOBEGFI -NEWBATHROOMLIGHTFIXTURES BATHROOM2:

PRIMARYBEDROOM: -NEWCLOSETLIGHTFIXTURESAINDICATED. -NEWCEILINGFIXTURE

NOTE: 1.NOCHIPPINGORCHANNELINGINTOEXISTING STRUCTUREFORRECESSEDLIGHTS.

2.NOTRENCHINGOFSTRUCTURALSLABSHALL BEDONEATANYLOCATION.

1.THECONTRACTORSHALLVERIFYALLCONDITIONSFORCLEARANCEOFMECHANICALUNITS,DUCTWORK,PIPING,ETC,ANDNOTIFYTHEARCHITECTOF ANYDISCREPANCIESPRIORTOPROCEEDING.

2.THECONTRACTORSHALLSUBMITCOORDINATEDSHOPDRAWINGSFORARCHITECTAPPROVALAT3/8"=1'-0"INDICATINGTHEFOLLOWING: A.)PARTITIONSB.)LAYOUTOFLIGHTFIXTURESC.)DUCTWORK,DIFFUSERSANDACCESSPANELSD.)STRUCTURE

3.REFERTOLIGHTFIXTURESCHEDULE&INSTALLINACCORDANCEWITHMANUFACTURER'SDIRECTIONS.

4.DIMENSIONSARETOTHECENTERLINEOFTHEFIXTURE,UNLESSOTHERWISENOTED.

5.VERIFYMAXIMUMACHIEVABLECEILINGHEIGHTSATTHEBEGINNINGOFCONSTRUCTIONANDNOTIFYARCHITECTIFANYCONDITIONSPREVENTTHE PROPOSEDHEIGHTSTOBECONSTRUCTED.ALLCEILINGHEIGHTSGIVENAREASSUMED,TOBEVERIFIEDONCEALLMECHANICALEQUIPMENTAND DUCTINGHAVEBEENINSTALLED.

7.ALLCEILINGHEIGHTSSHALLBEMEASUREDFROMTHEFINISHFLOORLEVELOFTHESPACEDESIGNATED.

8.PARTITIONSSHALLNOTBESECUREDORATTACHEDINANYWAYTODUCTWORK.

9.ALLSMOKEDETECTORS,DIFFUSERSANDGRILLESSHALLBECENTEREDAND/ORALIGNEDWITHSURROUNDINGARCHITECTURALELEMENTSU.O.N.

11.ALLCEILINGSSHALLBELEVELANDINALIGNMENT.PROVIDEFIRERATEDHOUSINGFORRECESSEDLIGHTSORPROTECTIVEFIRERATEDENCLOSURES. MAINTAINFIRERATINGOFCEILING.

12.COORDINATELIGHTFIXTURELAYOUTWITHLAYOUTOFPIPESANDEQUIPMENT.

13.PROVIDEBLOCKINGATALLHANGINGFIXTURELOCATIONS.

14.LIGHTFIXTURESINSMALLSPACES(I.E.CLOSETS,VESTIBULES,UTILITYROOMS,ETC.)SHALLBECENTEREDINTHESPACEUNLESSOTHERWISENOTED. 15.ALLHARDWIREDCARBONMONOXIDEDETECTORSSHALLCOMPLYWITHRS17-13ANDBEINSTALLEDINACCORDANCEWITH17-14&LL/2004.

16.REFLECTEDCEILINGPLANSAREFORCOORDINATIONPURPOSESONLYREFERTOENGINEERINGDRAWINGSFORLIGHTING,HVAC,SPRINKLER,ETC.

ENTIREAPARTMENT: -NEWOUTLETSANDELECTRICALWIRING THROUGHOUTAPARTMENTTOCOMPLYWITH 2020NYCECCC.LOCATIONSASINDICATEDON PLAN. KITCHEN: -ANYNEWKITCHENOUTLETSTOBEGFI -PROVIDEDEDICATEDOUTLETANDCIRCUITFOR NEWDISHWASHER -NEWCEILINGFIXTURE

BEDROOM2: -NEWCLOSETLIGHTFIXTUREASINDICATED.

BEDROOMDINING: -NEWBARSTOBEINSTALLEDINSIDEALLWINDOW WELL. -NEWLIGHTFIXTURES.SEEA-800FORMORE INFORMATION

BUILDINGSPECIFICNOTES:

1.ALLELECTRICALWORKMUSTBEPERFORMEDBYALICENSEDELECTRICIAN,WHOSHALLARRANGEFORANDOBTAINALLREQUIREDPERMITS, INSPECTIONS,ANDSIGN-OFFSTHROUGHTHEDOBBUREAUOFELECTRICALCONTROL.

2.DUPLEXOUTLETSINKITCHENANDBATHROOMSARETOBEGFCITYPE.DRAWINGSMUSTINDICATEGFCIAND/ORAFCIASAPPROPRIATEPROTECTION FORALLNEWGENERALPURPOSERECEPTACLEBRANCHCIRCUITSNYCELECTRICALCODE210.12,ANDTHATALLGENERALPURPOSERECEPTACLES SHALLBETAMPERRESISTANTTYPEASREQUIREDBYNYCELECTRICALCODE406.11.

3.ALLABANDONEDELECTRICALBOXESWITHREMAININGWIRINGENTERINGORLEAVINGSHALLREMAINACCESSIBLEWITHREMOVABLECOVERS.

4.THEELECTRICPANELANDINTERCOMPANELCANNOTBERE-LOCATEDWITHOUTSPECIFICWRITTENAPPROVAL.

5.ALLRECEPTACLE,SWITCH,ORLAMPHOLDERBOXESSHALLBESETFLUSHTOFINALFINISHEDSURFACE.EXTENDEXISTINGBOXESASNECESSARYOR UTILIZEPLASTERRINGSOROTHERDEVICESTOENSURETHATACONTINUOUSGROUNDEDMETALLICSURFACEISINPLACEBETWEENBOXESAND FACEPLATES.

6.NOCHOPPINGOFTHESLABORDEMISINGWALLSWILLBEPERMITTED.NEWWIRINGINWALLSMAYONLYBECONCEALEDWITHINTHEDEPTHOFTHE EXISTINGPLASTER,BEHINDMOLDINGS,ORCONCEALEDWITHINDRYWALLFURRING.WIRINGTOCEILINGFIXTURESMUSTBECONCEALEDINCONDULET ORADROPPEDCEILING.

7.IFPROPOSEDADDITIONALELECTRICALFIXTURESREQUIRENEWCIRCUITS,THEYMUSTBEPROVIDEDSOTHATTHEREISNOOVERLOADTOTHEMAIN CIRCUITOFTHEAPARTMENTAND/ORTHATOFTHEBUILDING.APANELSCHEDULESHOWINGRATINGSOFPANEL,NUMBEROFCIRCUITS,RATINGOF CIRCUITS,LOADS,ANDALLGFCIANDAFCICIRCUITBREAKERSMUSTBESUBMITTED.

SYMBOLLEGEND:

CHANDELIERPENDANTFIXTURE

SURFACEMOUNTEDCEILINGFIXTURE

WALLSCONCETYP.

CLOSETLIGHTFIXTUREW/JAMBSWITCH

NEWCONDUIT

SUPPLYANDINSTALLNEWELECTRICALPANEL,TOCOMPLYWITHNEC2011CODEAS AMENDEDBYNYC.

SUPPLYANDINSTALLNEWSMARTDIMMERS,FORALLSWITCHESWITHSTANDARDWHITE COVERPLATESANDDECORATIVEFACEPLATESSTANDARDWHITEBY"LUTON"TYPE THROUGHOUT.

COORDINATEWITHARCHETYPE,G.C.TOPROVIDEDIMMERSTHATARECOMPATIBLEWITH OWNERSUPPLIEDLIGHTFIXTURES.

SUPPLYANDINSTALLNEWALLNEWELECTRICALOUTLETSTOCOMPLYWITHNEC2011 CODEASAMENDEDBYNYC.CONFIRMALLLOCATIONSTOBEFURREDOUT.

PROVIDE&INSTALLNEWWIRINGINSIDEWALLSFORSWITCHESANDOUTLETSASNEEDED. PLASTER,PATCH,SANDANDSKIMCOATWALLSANDCEILINGSTHROUGHOUTWHERE ELECTRICALLINESHAVEBEENMODIFIED.

PROVIDECEILINGDROPSTOACCOMMODATECEILINGLIGHTS&CONDUITSASINDICATED. NOCHIPPINGOFEXISTINGCEILINGISPERMITTEDBYTHEBUILDING.COORDINATEWITHG.C. FORFINALCEILINGHEIGHTS.

INSTALLALLNEWOWNERSUPPLIEDCEILINGMOUNTED&RECESSEDLIGHTFIXTURES, WALLSCONCES,SURFACEMOUNTEDLIGHTS,UNDERCABINETLIGHTSTHROUGHOUT APARTMENT,ALLLIGHTSTOBEONDIMMERSCOMPATIBLETOOWNERSELECTEDLIGHTS. REFERTOARCHETYPE'SSEPARATESPECSFORALLAPPLIANCESANDLIGHTINGFIXTURES. PROVIDEACCESSIBLELOCATIONFORTRANSFORMERS.

SUPPLYANDINSTALLNEWELECTRICAL,PHONE,INTERNET/DATAANDCABLEOUTLETS THROUGHOUTASINDICATED.VERIFYMOUNTINGHEIGHTSWITHOWNER.

TOSUPPLYANDINSTALLALLDEDICATEDCABLE,INTERNET,HDMIANDELECTRICAL OUTLETSFORWALLHUNGTVLOCATIONSASINDICATED.G.C.TOSUPPLYANDRUNHDMI WIRES.VERIFYTVMOUNTINGHEIGHTWITHOWNER.PROVIDEPLYWOODBLOCKINGAS NECESSARY.PROVIDECABLERUN,INTERNETANDQUADOUTLETATAVCLOSETASSHOWN.

RELOCATEINTERCOMBACKTOORIGINALLOCATION

SUPPLY&INSTALLNEWHARDWIREDSMOKE&CARBONMONOXIDEDETECTORSASSHOWN ONPLANSANDINACCORDANCEWITHCURRENTCODECOMPLIANCE.

SUPPLY&INSTALLANDWIREFORNEWDEDICATEDA/COUTLETSASREQUIREDBYCODE. G.C.TOCOORDINATEWITHOWNER'SACSPECIFICATIONSFOROUTLETSLOCATIONS.

SUPPLY&INSTALLNEWDEDICATEDELECTRICALGFI&CONVENIENCEOUTLETS THROUGHOUTKITCHEN&BATHROOMSINCLUDINGNEWWASHERANDDRYERATLAUNDRY CLOSETASSHOWNONPLANSANDASPERAPPLIANCESMANUFACTURER'S RECOMMENDATIONS.EXISTINGELECTRICALOUTLETSSHALLREPLACEDTOCOMPLYWITH CURRENTELECTRICALCODE.

SUPPLYANDINSTALLALLNEWSWITCHESFORALLCLOSETLIGHTS.

*OUTLETSTOBE"SCREWLESS"ASPEROWNER

ELECTRICALOUTLET*-QUAD.

ELECTRICALOUTLET-DUPLEX

D SD S IN-FLOORELECTRICALOUTLET-QUAD. IN-FLOORELECTRICALOUTLET-DUPLEX

ELECTRICALPANEL

SDCO SMOKE/CARBONMONOXIDE DETECTORASPERRS-1713/14 ALSOTOCOMPLYWITHLL7/04

ELECTRICALOUTLET-CONNECTTOSWITCH S WPELECTRICALOUTLET-WATERPROOF(EXTERIOR)

DATAINTERNET-1CAT6/1RG6 (COORDINATEWITHAVCONSULTANT) TV-4CAT6WIRES TV

LINEOFCIRCUIT SWITCH J.S. CABLELINE

*NOTE:USEWATERPROOFHOUSINGANDTRIM FORALLRECESSEDLIGHTSINWETAREAS WALLSCONCE@BATHROOM J.S THREE-WAYSWITCH S3

EXHAUSTFANREFERTOMEP SPECIFICATIONS

DIMMERSWITCH(COORD.WITH AVCONSULTANT)

ELECTRICJAMBSWITCH@ALL CLOSETS(U.O.N.)

INTERCOM2CAT6

LAUNDRY:

BATHROOM: -EXISTINGBATHROOMVANITY,TOILETANDSHOWERTO REMAIN. BATHROOM2: -NEWLINESFROMFIXTURESTOTHERISERS RUNNINGINSIDEFURRED-OUTWALLS -BATHTUBTOREMAININSAMELOCATIONSEE BATH&SHOWERDETAILSONG-003.NEW

8.PLUMBERMUSTCHECKEXISTINGWASTEANDVENTLINESTOBEFREEOFOBSTRUCTION. 9.WATERSUPPLYNOTESORDIAGRAMSMUSTINDICATEBACKFLOWPREVENTIONDEVICESON ALLHARD-PIPEDFIXTURESANDAPPLIANCES.THISAPPLIESTOREFRIGERATORICEMAKER (IFANY)ANDDISHWASHER.

10.CHECKVALVESMUSTBEFURNISHEDONBRANCHPIPINGFORHOTANDCOLDWATER SUPPLYADJACENTTOMASTERSHUT-OFFVALVES.CHECKVALVESMUSTBEQUIETTYPE.

11.ALLHOTANDCOLDWATERPIPINGISTOBEINSULATED,MINIMUM½"THICKNESS.THIS INCLUDESEXISTINGLINESFOUNDTOBEUNINSULATEDDURINGDEMOLITION.

12.ALLHOTANDCOLDWATERPIPINGATFIXTURESISTOBETERMINATEDWITHAIRCHAMBERS (WATERHAMMERARRESTORS)RISINGABOVETHEFIXTURE.

13.FIXTUREPIPINGBETWEENSHUT-OFFVALVEANDTHEFAUCETORAPPLICATIONTOBE COPPERTUBINGWITHFLAREDENDSANDBRASSBUSHINGS.(NOPLASTIC,RUBBER,OR BRAIDEDSTAINLESSSTEEL.)

14.NOREINFORCEDRUBBERHOSEWILLBEALLOWEDINPIPINGTOFIXTURESANDAPPLIANCES. HIGHPRESSURE"NOBURST"BRAIDEDSTAINLESSSTEELWILLBEALLOWEDTOHOOKUP FIXTURESANDAPPLIANCESTHATDONOTHAVEACCESSAFTERINSTALLATIONIF DEMONSTRATEDTHEREISNOPRACTICALALTERNATIVE.

15.DISHWASHERDRAINMUSTEITHERHAVEALOOPRISINGTOUNDERSIDEOFCOUNTERTOP FLOODLEVELRIMOFTHESINKORABACKFLOWPREVENTIONDEVICE.THISMUSTBESHOWN ONRISERDIAGRAMORBYANAPPROPRIATENOTE.

16.ITMUSTBEVERIFIEDWHETHERREFRIGERATORHASANICEMAKERORWATERDISPENSER.IF SO,THEPIPINGMUSTBERUNABOVETHEFLOOR.TUBINGTOREFRIGERATORMUSTBE CONFIGUREDINALOOPBACKTOAVALVEANDTHENADRAIN,SOTHATTHELOWVOLUME FEEDMAYBEFLUSHEDOUTASNECESSARY.INSTALLATIONMUSTBEOBSERVEDBY BUILDINGSUPERINTENDENT.

17.WALLHUNGTOILETSWILLBEALLOWEDONLYWITHFULLHEIGHTWALLCARRIERS,FLOOR TOSLABABOVE,WITHINSULATIONPACKEDINTHEENTIREPIPECHASETOMINIMIZENOISE TRANSMISSION.CONCEALEDTANKMUSTBEWATERPROOFEDTOCEILING.DETAILSMUSTBE PROVIDED,INCLUDINGCONNECTIONTOWASTESTACK.

11.PROVIDENEWMASTERSHUT-OFFVALVESANDBRANCHLINESFORHOTANDCOLDWATER SUPPLYFORRE-HABBEDBATHROOMSANDKITCHEN.ALLVALVESMUSTBEFULLPORT,OF USMANUFACTURE.ALLNEWCOPPERPIPINGFROMTHEMASTERSHUT-OFFVALVETOEACH

FIXTURE.PROVIDENEWSHUT-OFFVALVESATEACHFIXTURE,ASFOLLOWS:

11.1.BATHROOM HOTWATERMASTERSHUT-OFFVALVE COLDWATERMASTERSHUT-OFFVALVE HOTWATERSHUT-OFFVALVEATLAVATORY COLDWATERSHUT-OFFVALVEATLAVATORY SHOWERVALVE(TEMPERATURERANGE110ºFTO120ºF) COLDWATERSHUT-OFFVALVETOTOILET

11.2.KITCHEN COLDWATERSHUT-OFFVALVE HOTWATERSHUT-OFFVALVE CHECKVALVEFORREFRIGERATORANDDISHWASHERSUPPLY

12.WHENEVERRADIATORSAREREMOVED,REPLACED,ORRELOCATED,BRANCHPIPINGMUST BEREPLACEDBACKTOTHERISERS.

13.BUILT-INCABINETSCONCEALINGRADIATORS,CONVECTORS,THRU-WALLUNITS,ANDFAN COILUNITSMUSTBEEASILYREMOVEDFORPROPERSERVICEANDMAINTENANCEOFUNITS, VALVES,ANDPIPING.

14.BATHROOMTILINGONCEILINGSWILLNOTBEALLOWEDWHEREITWOULDPREVENTACCESS TOOVERHEADPIPING.

15.NOGASPIPINGCHANGESAREINDICATEDANDNONEWILLBEALLOWEDASAPARTOFTHIS ALTERATION.

ENTIREAPARTMENT: -EXISTINGRADIATORSTOREMAIN

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.