FIRESTOPPINGDETAIL:
A.PACKALLSPACESFULLDEPTHW/MINERALWOOLOROTHEREQUALLYAPPROVEDFIRERESISTIVEMATERIAL(ASBESTOSORFIBERGLASS SHOULDNOTBEUSED).FIRERESISTANTFOAMSEALANTCHASEFOAMCTCP2-655MAYBEUSED.INSTALLATIONASPERMANUFACTURER.
B.ESCUTCHEONBOTHSIDES C.SLEEVE
D.INSULATION(OUTSIDEDIAMETER)
E.ANHYDROUSCALCIUMSILICATEINSULATIONTHRUSLEEVE
F.FIRERATEDPARTITION,WALLORFLOOR
G.FIBERGLASSINSULATION
H.TERMINATEINSULATIONATESCUTCHEON
I.MAXIMUM1/2"CLEARANCEBETWEENINSIDEOFSLEEVE&PIPE
DETAILOFPIPINGPIERCINGFIRERATEDPARTITIONS,WALLS&FLOORS
7.NOACCUMULATIONORDEBRISORREMOVED MATERIALS/EQUIPMENTWILLBEPERMITTED, CONTRACTORTOREMOVETHESEMATERIALS FROMSITEDAILY.
8.THEARCHITECTSHALLASCERTAINPRIORTO REMOVALTHATCOMPONENT/ITEMBEING REMOVEDISNONSTRUCTURAL.CONTRACTOR SHALLNOTIFYARCHITECT/STRUCTURALENGINEER OFANYDEVIATIONOFSTRUCTURALCONDITIONS FROMTHESESHOWNONTHEPLANS.
9.PRIORTOCOMMENCEMENTOFWORK,THE GENERALCONTRACTORTOFIELDVERIFY& IDENTIFYEXISTINGEQUIPMENTTOREMAININ SERVICETHATISSERVEDBYSYSTEMSTOBE REMOVED.REMOVEAND/ORRELOCATETHE SERVICESASDIRECTED.
10.ANYEXISTINGUTILITYSERVICESTOBEREMOVED, TERMINATED,ORDISCONNECTEDFORFUTURE RELOCATIONSHALLBECUT,CAPPED,SEALEDOR REMOVEDINACCORDANCEWITHAPPLICABLE CODESANDUTILITYCOMPANYREQUIREMENTS ANDRECOMMENDATIONS.
11.THEGENERALCONTRACTORWILLBE RESPONSIBLETOREMOVEALLABANDONED EQUIPMENTWITHINTHESPACE-CONFIRMWITH OWNERIFTOBEDISCARDEDORTOBEREUSED.
12.THEGENERALCONTRACTORSHALLBE
RESPONSIBLEFORMAINTAININGUSEOFALL UTILITIES,EXCEPTTHOSETOBEREMOVEDOR RELOCATEDFOREXTENTOFDEMOLITIONWORK. UTILITYINTERRUPTIONSMUSTBESCHEDULED WITHOWNERPRIORTOWORK.CONTRACTORIS RESPONSIBLEFORALLELECTRICREQUIREDTO HAVEPERMANENTORTEMPORARYPOWERTO THESITEDURINGCONSTRUCTION.
13.NOPLUMBINGWILLPROJECTINTOORBELOWTHE STRUCTURALSLABANDNOSTRUCTURALSLABS TOBECHANNELED.
14.NOBUILDINGVENTSTOBEDEMO,PROTECT DURINGDEMOLITION.
15.NOSTRUCTURALELEMENTSTOBEREMOVED. PROTECTANDINSULATEOPENINGSLEADINGTO STRUCTURALELEMENTS.SEEWALLDETAILSAND TOCOMPLYWITHBUILDINGCODEAND REGULATIONS.
16.CUTTINGORCHOPPINGOFFTHEEXISTING STRUCTURALCONCRETESLABFORPLUMBINGOR FORANYOTHERPURPOSEISNOTPERMITTED,SO ASNOTTOAFFECTTHESTRUCTURALINTEGRITY OFTHEBUILDING.
17.THECONTRACTORSHALLNOTDISRUPTANY EXISTINGGASRISERS,PLUMBINGRISERS,DATA/ INTERCOMCABLETELEPHONECONDUITS,HVAC
LINES,DUCTWORK,ORPOWERLINESTHATARE EXISTINGINTHEINTERIORAREASOFTHE APARTMENTTHATSERVICEOTHERPORTIONSOF THEBUILDING.
18.THEGENERALCONTRACTORSHALLBE RESPONSIBLETOPROTECTALLEXISTING WINDOWSTOREMAIN.CONTRACTORISTO PROTECTWINDOWSBEFORESTARTINGANY REMOVALORWORKINGENERALANDSHALLHAVE PROTECTIONOBSERVEDBYTHEOWNER'S REPRESENTATIVEPRIORTOSTARTOFWORK. CONTRACTOROROWNER'SREPRESENTATIVE SHALLMAKEADETAILEDPHOTOGRAPHIC INVENTORYOFTHECONDITIONOFTHEWINDOWS PRIORTOCONTRACTOR'SPROTECTIONBEINGPUT INPLACEANDTHESTARTOFWORK.
19.THEARCHITECTOFRECORDANDCONTRACTOR SHALLVERIFYTHATANYPORTIONOFWALLSTO BEDEMOLISHEDARENON-LOADBEARINGWALLS ANDANYNEWCONSTRUCTIONOFWALLSAND CEILINGSHALLFOLLOWNYCCODESAND REGULATIONSINCLUDINGBUTNOTLIMITEDTO ALLSOUNDPROOFING,WATERPROOFINGANDFIRE RATINGS.
20.IFSOMETHINGINDICATEDONTHEPLANOR DISCOVEREDINTHEFIELDISNOTSPECIFICALLY IDENTIFIEDTOBEREMOVEDORTOREMAINONTHE
PLANS,CONTRACTORSHALLREQUESTDIRECTION FROMARCHETYPEPRIORTOREMOVAL.
21.ARCHITECTISRESPONSIBLEFORTHETEMPORARY SHORINGDESIGN.SUBMITDETAILSANDDESIGN CALCULATIONSBEARINGTHESEALOFALICENSED PROFESSIONALORSTRUCTURALENGINEER'S REVIEWBEFORECONSTRUCTIONOFSHORING. 22.SAFETYZONE:ASAFETYZONESHALLBEPROVIDED AROUNDALLWORKAREASTOPREVENTPERSONS OTHERTHANWORKERSFROMENTERINGSUCH ZONE.WHEREWORKOCCURSONTHEEXTERIOR OFABUILDING,SUCHZONESHALLBEAPPROVED BYTHECOMMISSIONERPRIORTOTHE COMMENCEMENTOFWORK.
23.SEQUENCE:ANYSTRUCTURALMEMBERTHATIS BEINGDISMEMBEREDSHALLNOTSUPPORTANY LOADOTHERTHANITSOWNWEIGHT.NOWALL, CHIMNEY,OROTHERSTRUCTURALPARTSHALLBE LEFTINSUCHCONDITIONTHATITMAYCOLLAPSE ORBETOPPLEDBYWIND,VIBRATIONORANY OTHERCAUSE.THEMETHODOFREMOVALOFANY STRUCTURALMEMBERSHALLNOTDESTABILIZE REMAININGMEMBERS.ALLHANDLINGAND MOVEMENTOFMATERIALORDEBRISSHALLBE CONTROLLEDSUCHTHATITWILLNOTDEVELOP UNACCOUNTEDIMPACTLOADSONTHE STRUCTURE.
28.EXISTINGGASRISERINTHEKITCHENSHALLBE LOCATEDANDPROTECTEDFROMDAMAGEPRIOR TOTHESTARTOFWORK,ANDREMAINPROTECTED FORTHEDURATIONOFTHEPROJECT.
29.PRIORTOBEGINNINGDEMOLITIONOR CONSTRUCTION,PROTECTMECHANICALEXHAUST VENTSINTHEWORKAREASUSINGPLASTIC SHEETINGTOPREVENTDUSTMIGRATIONTO OTHERAREAS.
30.GENERALCONTRACTORTOCOMPLYWITH BUILDINGREGULATIONSONWHATDEMOLITION EQUIPMENTAREPERMISSIBLE.
KEYNOTES: ALLAPARTMENT
REMOVEINTERIORGLASSPARTITIONSINCLUDING MOLDINGS,BASEBOARDANDDOORS. D01
REMOVEALLFLOORING,BASEBOARD,CROWN MOLDINGANDWALLFINISHES.REPAIRANDPREP FORNEWFINISH. D02
REMOVEALLEXISTINGFLOOROUTLETS.D03
REMOVEPARTITIONWALLS,DOORS,MOLDINGS, ANDELECTRICALWIRING. D04
REMOVEALLEXISTINGELECTRICALOUTLETSON DEMOLISHEDWALLS. D05
REMOVEEXISTINGBASEBOARDRADIATOR COVERS,TOBEREPLACED. D06 D07ALLEXISTINGWINDOWSTOREMAIN. D08
REMOVEEXISTINGCLOSETINTERIORS.
BATHROOMS
REMOVEALLEXISTINGFINISHES,PLUMBING,AND DECORATIVEFIXTURES. D09
REMOVEALLEXISTINGPLUMBINGFIXTURESTUB SHOWERSINKTOILET.CAPANDRETURN EXISTINGPLUMBINGLINESBACKTORISER. D10
REMOVEEXISTINGCEILINGVENTSGRILLSIN ALLBATHROOMS,PROTECTALLBUILDINGDUCTS ANDSTRUCTURALELEMENTSDURING DEMOLITION.
INSPECTBUILDINGRISERLOCATIONS.ALLRISERS TOBEPROTECTEDATALLTIMESDURING DEMOLITION. D12
REMOVEEXISTINGWASHER/DRYER.CAPAND RETURNEXISTINGLINESBACKTORISER. D13
KITCHEN
CAPANDREMOVEEXISTINGGASRANGEBACKTO RISER.EXISTINGGASLOCKVALVETOREMAIN. PROTECTATALLTIMES. D REMOVEREFRIGERATORSUPPLYLINE,NEWLINE TOBELOCATEDINNEWLOCATION,. D
REMOVEALLEXISTINGAPPLIANCESAND FIXTURES:SINK,DISHWASHERANDWINECOOLER. CAPANDRETURNEXISTINGLINESBACKTORISER
REMOVEALLEXISTINGCABINETRY,
REMOVEALLEXISTINGSOFFITSANDDROP CEILINGS,DUCTWORK&EQUIPMENT.EXISTING STRUCTURALBEAMSTOREMAIN.PROTECTATALL TIMES.
REMOVEALLEXISTINGLIGHTINGFIXTURE,HVAC GRILLS,ACCESSPANELS,ANDCEILINGMOUNTED EQUIPMENT
REMOVEALLEXISTINGWALLSASMUCHAS POSSIBLEUPTOBUILDINGRISERS.ALLWALLSTO BEREFRAMEDASTIGHTASPOSSIBLE.ALLRISERS TOBEPROTECTEDATALLTIMESDURING DEMOLITION.
GRAPHICLEGEND:
EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN
EXISTINGINTERIORWALLSOR ELEMENTSTOBEREMOVED
NOTE:ALLWALLS&PARTITIONSBEING REMOVEDARENOTLOADBEARING.
ELECTRICALPANEL
EXISTINGDOORTOREMAINUNLESS NOTEDOTHERWISE
GENERALCONTRACTORTOCOORDINATEWITHBUILDING
MANAGERALLBUILDING'SREQUIREDPROGRESS INSPECTIONS:
·PREPARATIONOFDIRT&DUSTCONTROLPROCEDURES
·COMPLETIONOFDEMOLITIONANDFIRESTOPPINGAND FIREPROOFINGIFREQUIRED.
·COMPLETIONOFELECTRICALANDPLUMBINGROUGHIN COMPLETIONOFSOUNDPROOFINGAND WATERPROOFING
·COMPLETIONOFMECHANICALEQUIPMENT INSTALLATION
·COMPLETIONOFPROJECTPRIORTODOBAND ELECTRICALSIGN-OFF
18.SUPPLY&INSTALLNEWCUSTOMBASEMOLDINGS,PICTUREMOLDINGSANDDOORCASINGMOLDINGSTHROUGHOUTENTIRE APARTMENTASSHOWNINPLANS.DYKESOREQUAL.
19.ALLAREASUNCOVEREDBYWORKTHATAREDISCOVEREDTOBEMISSINGFIRESTOPPINGORINSULATIONMUSTBEADDRESSED.
20.GCTONOTIFYBUILDINGIFANYWORKNEEDSHOISTING.NOPROPOSEDWORKREQUIRESHOISTING.
21.THEPLYWOODTOBEADDEDFORBLOCKINGMUSTBEFIRE-TREATED
22.ASTHISISASPRINKLEREDBUILDING,NOTETHATFIBEROCKAQUA-TOUGHGYPSUMPANELS,MOLDTOUGHBOARDOREQUALMUSTBE USED.
23.ALLNEWSUSPENDEDCEILINGCONSTRUCTIONSHALLCONSISTOFSUPPORTINGHANGERRODS,CHANNELSANDGRIDASREQUIREDBY THENEWYORKCITYBUILDINGCODE.NOTETHATADHESIVE,MECHANICALANDSCREWANCHORSNOWREQUIREASPECIALINSPECTION BYACERTIFIEDINSPECTORPERSEC.BC1701OFTHE2014BUILDINGCODE.
24.ONLYWATER-BASEDSEALANTSMAYBEUSEDFOR(RE)FINISHINGOFWOODFLOORINGORCABINETRY.PRIORTOSANDINGAND REFINISHINGWOODFLOORING,ADUSTCONTAINMENTVESTIBULEANDNEGATIVEAIRPRESSUREMACHINESSHALLBEUTILIZEDPER MANUFACTURER'SGUIDELINESANDASDIRECTEDBYBUILDINGMANAGEMENTANDBUILDINGGUIDELINES.ALLOPENINGSINFLOORS, WALLSANDCEILINGSTHATCOULDLEADTODUSTESCAPINGTOOTHERAPARTMENTSORBUILDINGSPACESMUSTBESEALED. NEGATIVEAIRPRESSUREMACHINESREDUCEDUSTINFILTRATIONTOADJACENTUNITSANDPUBLICSPACESOUTSIDEOFTHEUNIT BEINGALTERED,PARTICULATEDUSTWITHINTHEWORKAREA,CLEANUPANDMAINTENANCETIME,ANDUNPLEASANTODORS. 25.THECONTRACTORISREQUIREDTOPROTECTALLPUBLICSTAIRWAYS/HALLWAYSPRIORTOSTARTOFDEMOLITIONUNTILALL ALTERATIONWORKISCOMPLETED.
26.G.CSHALLCONFIRMANDBERESPONSIBLETHATAFTERWORKHASBEENCOMPLETEDALLTHEEXISTINGANDNEWELECTRICAL EQUIPMENTSANDFIXTURES,INCLUDINGBUTNOTLIMITEDTO(APPLIANCES,HVACUNITS,AVEQUIPMENTS,ETC.)ARECONNECTED, FUNCTIONINGANDWORKING.
27.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTINGWALLANDFLOORSTHROUGHOUTAPARTMENT.
28.CONTRACTORSHALLSUPPLYCOORDINATEDSHOPDRAWINGSFORARCHITECTAPPROVALAT"=1'-0"INDICATINGTHEFOLLOWING: A)PARTITIONSB)LAYOUTOFLIGHTFIXTURES C)DUCTWORK,DIFFUSERSANDACCESSPANELSD)STRUCTURE
A50NEWFLOORTOREPLACEEXISTINGFLOOR.SEE FINISHPLAN.SEESCHEDULESFORSPECS.
A51INSTALLATIONOFNEWKITCHEN,BATHROOM,WETAREAS, FLOORINGMUSTINCLUDEADEQUATEWATERPROOFING. THEENTIREFLOORAREATOBEWATERPROOFEDWITHA LIQUIDAPPLIEDMONOLITHICMEMBRANESUCHAS LATICRETEHYDROBANORANAPPROVEDEQUIVALENT. WATERPROOFINGMUSTEXTENDNOFEWERTHAN(6) INCHESUPTHEPERIMETERWALLS.THEMEMBRANEMUST RUNWALLTOWALL,UNDERALLCABINETS,FIXTURES, TUBS,PANS,EQUIPMENT,RAISEDPLATFORMAND APPLIANCES,RETURN6"UPALLWALLSANDTO FULL-CEILINGHEIGHTINTHESHOWERAREA.THE WATERPROFFINGMUSTTIEINTOASUITABLEDOOR SADDLE.SEEDETAILSONP-100/101/102.
A52FORALLNEWWALLNICHEMEDICINECABINETSTORAGE FUTUREANSIREQUIREDBATHROOMGRABBARSG.C.TO PROVIDEBLOCKINGBRACKETSFRAMING.SEEELEVATIONS. G.C.TOCONFIRMWITHARCHITECTONDISCOVERIESOFANY UNFORESEENEXISTINGCONDITIONSDURINGDEMOLITIONOF WALLOPENINGS.G.C.TOPROTECTPATCHANDREPAIRALL OPENINGSCREATED.G.C.TOPROTECTPLUMBINGRISERS STRUCTURALELEMENTSDURINGDEMOLITIONSAND CONSTRUCTION.
PRIMARYBEDROOM
A37ELECTRICWATERVAPORFIREPLACE.W/KEF SPEAKERSINTEGRATEDINTOMILLWORK. SPEAKERSHARDWIREDTOGETHER. A38STORAGESHELVING
A39NOTUSED. A40NOTUSED. A41NOTUSED.
PRIMARYBATHROOM A42NEWVANITY/SINKWITHBUILT-INHAMPER,NEW TUB,NEWSELF-WASHTOILET,ALLTOBEINNEW LOCATION.PROVIDENEWROUGHINS,NEWLINES TOCONNECTTOEXISTINGRISER. A43NEWRADIANTHEATINGFLOOR.SEEFINISHPLAN A44BUILT-INMEDICINECABINET. A45ANTI-FOGLITMAKE-UPMIRROR. A46SURFACEMOUNTEDMAKEUPMIRRORON SWIVELARM A47ELECTROSTATICPRIVACYFILMINSTALLEDON SHOWERGLASSWALL.
A48BATHROOMFLOORRAISEDTOACC.BATHDRAIN BACKTORISER.SEEDETAILONP-102 A49NOTUSED
GLASSPARTITIONWITHETCHEDPATTERNAND METALACCENTSWITHSLIDINGDOORS
WIRINGASREQUIRED.
GLASSPARTITIONWITHETCHEDPATTERNAND METALACCENTS A09
BATHROOM#3
WALLNICHELOCATIONTOBEDETERMINEAFTER DEMOLITION A10
NEWSHOWERTOREPLACEWASHERDRYER LOCATION. A11
NORADIANTHEATINGFLOOR.A12
NEWSELF-WASHWALLHUNGTOILETINNEW LOCATION. A13
NEWBUILT-INMEDICINECABINET,VANITYINNEW LOCATION,DEPTHOFMEDICINECABINETTOBE DETERMINEAFTERDEMOLITION. A14
A15NEWCLOSETS A16NOTUSED KITCHEN
A17NOTUSED.
A18NEWMOVEABLEKITCHENBANQUETTE.WINDOWS TOBEACCESSIBLEFORMAINTENANCE.
A19NEWGASRANGETOBEREPLACEDINEXISTING LOCATION.REUSEEXISTINGAPARTMENTGAS LOCKVALVE
A20NEWKITCHENMILLWORKANDAPPLIACNESTOBE INSTALLED
A21NOTUSED LAUNDRY
A22INSTALLNEWWATERPROOFMEMBRANE (LATICRETE9235ORAPPROVEDEQUAL)AND SPECIFIEDSOUNDMATTING. INSTALLNEWSTACKWASHER/VENTEDDRYERIN NEWLOCATION.PLUMBERTOPROVIDE NECESSARYLEAKDETECTIONDEVICESANDPAN. SEESHEETA-101FORFLOORDETAILS. NEWROUGH-INSTOBEUSEDTOACCOMMODATE WASHERDRAINAGE.
BEDROOM#2
A23NEWWINDOWBENCHW/INTEGRATEDSTORAGE. A24TALLMILLWORKSTORAGEAROUNDCOLUMNS.
BATHROOM#2
A25NEWSELFWASHTOILET&SINKTOBEREPLACED INEXISTINGLOCATION,NEWSHOWERTO REPLACETUBINEXISTINGLOCATION.PROVIDE NEWROUGHINS.
A26NEWBUILTINMEDICINECABINET
A27NEWRADIANTHEATINGFLOOR,SEEFINISHPLAN
BATHROOM#1
A28NEWVANITY/SINK,SELF-WASHTOILET& SHOWERTOBEREPLACEINNEWLOCATION. PROVIDENEWROUGHINS,NEWLINESTO CONNECTTOEXISTINGRISER.
A29SHOWERW/BENCHANDSHOWERSHELF.
A30NEWSTEAMSHOWER
A31NEWRADIANTHEATINGFLOOR,SEEFINISHPLAN
A32BUILT-INMEDICINECABINET
A33ANTI-FOGLITMIRRORINSIDESHOWER.
A34VANITYWITHBUILT-INHAMPERFOGMIRROR ABOVEVANITY.
A35INSTALLBLOCKINGFORHANDLERBARSIN SHOWER
A36ELECTROSTATICPRIVACYFILMINSTALLEDON SHOWERGLASSWALL.
EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN
PITCH,1/4"/FT.(MINIMUM1/8")
A22
A37 A38
GENIEMATRST-5 GLUEDTOFF-10.
GENIEMATFF-10 DIMPLEDMAT.
EXISTINGCONCRETESLAB TOREMAIN.
FINISHFLOORKEYNOTES:
INDICATESAREA(S)TORECEIVENEW WATERPROOFMEMBRANEREQUIRED BYBUILDINGRULESANDREGULATIONS. SPECTOBEKEMPERORAPPROVED EQUIVALENT.SEEWATERPROOFING NOTESFORSPECIFICAPPLICATION INSTRUCTIONS.
INDICATESAREA(S)TORECEIVENEW CARPETEDFLOORINGONEXISTING WOODFLOORING.
INDICATESAREA(S)TORECEIVENEW RADIANTFLOORHEATING
GENERALWATERPROOFING&SOUNDPROOFINGNOTES:
1.WPSYSTEMSBYLATICRETE(9235ORAPPROVEDEQUAL)WILLGENERALLYBE ACCEPTABLE.HOWEVERTHEBATHROOMEXPANSIONSANDKITCHEN EXPANSIONS,WHICHWILLFIRSTNEEDTOPROVIDECONFIRMATIONTHAT PLUMBINGMAINTAINSSLABINTEGRITYANDPITCH,WILLREQUIRE EXTRAORDINARYMEASURES.
2.FORBATHROOMWETOVERDRYEXPANSIONS,WHICHWILLREQUIRE BUILDINGAPPROVALWEWILLCONSIDERTHEUSEOFALIQUIDMEMBRANE PRODUCTLIKEKEMPUR,PROVIDEDTHAT:I.ITISINSTALLEDOVERA SACRIFICIALLAYERANDNOTINSTALLEDDIRECTLYONTHESTRUCTURAL SLAB.
3.ALOWODORPRODUCTISSPECIFIEDANDALLPRECAUTIONSAREMADETO PROTECTAGAINSTODORINFILTRATION.ACERTIFIEDINSTALLERISTOBE USED.THEDRAINISTOBEAPPROVEDBYTHEMANUFACTURER.KEMPER CANNOTBELAYEREDOVEROTHERWATERPROOFINGMATERIALSLIKE LATICRETEASTHEYARENOTCOMPATIBLEANDMAYTRAPMOISTURE. 4.PLEASECONFIRMHOWTHEEXPANSIONOFTHEKITCHENINTOTHEDINING AREAWILLADDRESSWATERPROOFINGANDWHERETHEWATERPROOFING MEMBRANEFROMTHEKITCHENWILLTERMINATE?ITDOESLOOKASTHOUGH THEWETFIXTURESARECONTAINEDWITHINTHEORIGINALKITCHEN FOOTPRINTBUTTHISNEEDSTOBECONFIRMED. 5.THEUSEOFASTEAMUNITISPROPOSED.THISWILLREQUIREBOARD APPROVAL.IFAPPROVEDBYTHEBOARD,THEUNITMUSTSITWITHINA WATERPROOFPANWITHANAUTOMATICSENSORALARMANDSHUT-OFF,AND THEUNITMUSTBEACCESSIBLE.LOCATETHESTEAMUNITINPLANAND SHOWPROVISIONFORACCESS.PROVIDESTEAMUNITSPECIFICATIONS,AS WELLASSPECIFICATIONSFORVIBRATIONISOLATORS(MASONINDUSTRIES OREQUAL)TOBEUSEDUNDERTHEUNIT.ELECTRICALSERVICETOTHE APARTMENTSHALLBEVERIFIEDASSTEAMUNITSAREHIGHDRAW APPLIANCES.THECONSTRUCTIONSHALLCOMPLYWITHTHEFOLLOWING REQUIREMENTS.THEENTIREENCLOSURESHALLHAVEVAPORBARRIER
INSTALLEDATWALLSANDCEILING.THEVAPORBARRIERMUSTOVERLAPTHE SHOWERLEADPAN.THEENTIREENCLOSURESHALLBECONSTRUCTEDOF CEMENTITIOUSWALLBOARDSUCHASDUROCK,ORAPPROVEDEQUALTHAT ISRATEDFORSTEAMSHOWERUSEATALLWALLSANDCEILING.THEENTIRE ENCLOSURESHALLBEWATERPROOFEDWITHLATICRETE9235ATFLOOR, WALLSANDCEILING,INCLUDINGNICHES,BENCHES,ETC.USEIMPERVIOUS FINISHTILESANDSURFACESTHROUGHOUTTHESTEAMSHOWER.INSTALL WATERPROOFTHERMALINSULATIONINWALLANDCEILINGFRAMING.THE CEILINGISRECOMMENDEDTOPITCHAMINIMUMOF2"PERFOOTTO PREVENTDRIPPINGOFHOTWATERONTOOCCUPANTS.
6.ALLSHOWERSSHALLHAVELEADPANSWHICHMUSTBECLAMPEDAND SEALED,ORSOLDERED,INTOANEWDRAINCOLLARANDMUSTCAPOVER THECURBEXTENDINGAMIN.OF4"UPTHEWALLABOVETHETOPOFCURB WHICHWILLDETERMINETHEHEIGHTATTHEPERIMETERSHOWERWALLS NOTETHATTHECURBMUSTBECONSTRUCTEDOFFORMEDCONCRETEAND THATWOODBLOCKINGMAYNOTBEUSED.NOTETHATTHEDRAINMUST HAVEWEEPHOLES.AFTERPASSINGA24-HOURWATERRETENTIONTEST, WITNESSEDBYTHERESIDENTMANAGER,THEENTIRELEADPANMUSTBE COATEDWITHASUITABLEWATERPROOFMASTICMEMBRANEPRIORTO INSTALLATIONOFTHEMORTARBEDTHEUNITOWNER'SREPRESENTATIVEIS TOSPECIFYAPRODUCTTHATISAPPROPRIATEFORCOATINGLEANPANS FORSHOWERSTHATWILLPROTECTTHELEADPANAGAINSTFUTURE CORROSION(NOTE:WE'VECONFIRMEDWITHLATICRETETHATHYDROBANIS NOTAPPROPRIATEFORTHISANDWEAREAWARETHATSOMEPEOPLEUSE MASTERSEALHLM500.ATAR-BASEDMASTICISAPPROPRIATE).TYPICALLY, THECOATEDLEADPANWILLBECOVEREDEITHERWITHACEMENTITIOUS MUDSETFORSTONESLABFLOORINGORTHINSETFORTILE.WHERENICHES AREPROPOSEDFORTUBANDSHOWERENCLOSURES,PROVIDE WATERPROOFINGTHROUGHOUTENTIRENICHE,ANDEXTENDINGAROUND ALLSIDESOFTHENICHEFACETOFORMACONTINUOUSMEMBRANEWITH
THEWATERPROOFINGMEMBRANEREQUIREDATTHESHOWER.SLOPE BOTTOMOFNICHETODRAIN.ATSHOWERBENCHESTHATFORMA CONTIGUOUSBOX-OUTWITHINTHESHOWERFOOTPRINT,THELEADPAN MUSTWRAPAROUNDALLSIDESOFTHEBENCHANDEXTENDAMINIMUMOF 4"UPTHEPERIMETERWALLSATTHETOPOFTHEBENCHASWELLAS ACROSSTHESIDEWALLSONTHEVERTICALPLANES.
7.THEAREAWITHINTHEWALLBELOWTHETANKOFABACKOUTLETTOILET ANDALLPLUMBINGLINESMUSTBEWATERPROOFED.THEWATERPROOFING AROUNDTHETANKMUSTEXTENDAMINIMUMOF12"ABOVETHEFLUSH VALVE.PENETRATIONSFORFASTENERSANDPIPINGMUSTBEFULLYSEALED.
8.FORFREEZERICEMAKERONLYCOPPERTUBINGMAYBEUSEDANDACCESS MUSTBEPROVIDEDFORFLUSHINGOUTTHESYSTEMANDCONFIRMINGNO LEAKS.
9.FORSOUNDPROOFING,WERECOMMENDTHATPRODUCTSMEETOREXCEED CODE.GENIEMATRST10(10MM);KINETICSSRFLOORBOARD5/8"THICK; COLBONDENKASONIC9110,10MM;QUIETCORK(JELINEKCORKGROUP),6MM; ANDSIKAACOUBOND(FORWOODFLOORSONLY).NOTETHATTHEEXISTING BUILDING'SFLOORCONSTRUCTIONANDTHESP'SPERFORMANCEUNDER WETCONDITIONSMUSTBECONSIDEREDINTHESELECTIONOFTHE APPROPRIATESOUNDPROOFINGPRODUCTFORWHICHTESTDATABASEDON REQUIREMENTSPRESCRIBEDBYTHENEWYORKCITYBUILDINGCODEMUST BEPROVIDED.PERIMETERISOLATIONISTOBEEMPLOYEDFORTHE INSTALLATIONOFALLSOUNDPROOFING.THESPINSTALLATIONMUSTBE INSPECTEDBYTHERESIDENTMANAGERPRIORTOTHEFINISHFLOORING INSTALLATION 10.SPEAKERS/SUBWOOFERS:PROVIDENECESSARYSOUNDISOLATIONTO ASSURETHATTHEREISNOSTRUCTURE-BORNENOISETRANSMITTANCE, WHICHISALIKELYOCCURRENCEWITHTHISEQUIPMENT,SUBWOOFERS MUSTBEMOUNTEDONMASONINDUSTRIESTYPESLFMETALSPRINGSOR EQUAL,SIZEDFORAMINIMUMDEFLECTIONOF1"UNDERTHEWEIGHTOFTHE
SPEAKERANDTHEBASE.THEMOUNTINGBASEMAYNEEDTOINCLUDESAND
INWTAREAS:LATICRETE9235
WATERPROOFINGMEMBRANE SHALLBETURNEDUPWALL6"
NEWFLOORTILES MUDSET GROUT
GENIEMATRST-5
GENIEMATFF-10 DIMPLEDMAT.
EXISTINGCONCRETESLAB TOREMAIN.
WATERRESISTANT GYP.BD. THINSET NEWWALLTILES PROVIDEPEROMETERISOLATIONAND ACOUSTICALSEALANTASPER MANUFACTURERSPECS. NEWFLOORTILES GROUT MUDSET
LATICRETEWATERPROOF MEMBRANEWITHFABRIC REINFORCEMENT
EXISTINGCONCRETE SLABTOREMAIN
GENERALFLOORINGNOTES:
1.ALLWORKSHALLBEINACCORDANCEWITHALLSTATEANDLOCALCODES. 2.COORDINATE&SUPERVISEALLTRADESANDPROVIDETHEDESIGNATED CLEARANCESSHOWNONTHESEDOCUMENTS.G.C.SHALLINFORMARCHETYPE PRIORTOPROCEEDINGWITHWORKTHATDIFFERSFROMTHEDESIGNINTENT.
3.ALLDIMENSIONSARETOBETAKENFROMFACEOFFINISHEDGYP.BOARDUNLESS OTHERWISEINDICATED.
4.PREPAREALLSURFACESFORFINISHESPERMANUFACTURERSPECIFICATIONS.
5.APPLY(3)COATSOFCLEARPOLYURETHANETONEWWOODFLOORSTHROUGHOUT ENTIREAPARTMENT.FLOORSTOBEPROTECTEDDURINGCONSTRUCTIONAS REQUIRED.USEWATERBASEDPOLYURETHANEONLY,ASREQUIREDBYBUILDING. 6.SEALALLPENETRATIONSTHROUGHALLFLOORS,WALLS&DOORS&ALLREDUCING STRIPSWHERECHANGESINFLOORFINISHESOCCUR.SUBMITSAMPLESFOR APPROVALTOARCHETYPE.
7.FLASH,PATCHANDLEVELTHEFLOORSASREQUIREDFORNEWFLOORFINISHES.
8.SUPPLYALLCONSTRUCTIONMATERIALSINCLUDINGBUTNOTLIMITEDFLOORING COMPOUNDS,GROUT,AND/ORGLUEASREQUIRED.
9.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTING FLOORSTHROUGHOUTAPARTMENT.
10.ALLFLOORFINISHESMUSTBEATTHESAMEFINISHELEVATIONUNLESSNOTED OTHERWISE.NOTIFYARCHETYPEIFTHISCANNOTBEACHIEVEDSOTHATANY DETAILSCANBEMODIFIEDACCORDINGLY. 11.FLOORINGTOEXTENDUNDERMILLWORKANDAPPLIANCES(TYPICAL).
18.SUPPLY&INSTALLNEWCUSTOMBASEMOLDINGS,PICTUREMOLDINGSANDDOORCASINGMOLDINGSTHROUGHOUTENTIRE APARTMENTASSHOWNINPLANS.DYKESOREQUAL.
19.ALLAREASUNCOVEREDBYWORKTHATAREDISCOVEREDTOBEMISSINGFIRESTOPPINGORINSULATIONMUSTBEADDRESSED.
20.GCTONOTIFYBUILDINGIFANYWORKNEEDSHOISTING.NOPROPOSEDWORKREQUIRESHOISTING.
21.THEPLYWOODTOBEADDEDFORBLOCKINGMUSTBEFIRE-TREATED
22.ASTHISISASPRINKLEREDBUILDING,NOTETHATFIBEROCKAQUA-TOUGHGYPSUMPANELS,MOLDTOUGHBOARDOREQUALMUSTBE USED.
23.ALLNEWSUSPENDEDCEILINGCONSTRUCTIONSHALLCONSISTOFSUPPORTINGHANGERRODS,CHANNELSANDGRIDASREQUIREDBY THENEWYORKCITYBUILDINGCODE.NOTETHATADHESIVE,MECHANICALANDSCREWANCHORSNOWREQUIREASPECIALINSPECTION BYACERTIFIEDINSPECTORPERSEC.BC1701OFTHE2014BUILDINGCODE.
24.ONLYWATER-BASEDSEALANTSMAYBEUSEDFOR(RE)FINISHINGOFWOODFLOORINGORCABINETRY.PRIORTOSANDINGAND REFINISHINGWOODFLOORING,ADUSTCONTAINMENTVESTIBULEANDNEGATIVEAIRPRESSUREMACHINESSHALLBEUTILIZEDPER MANUFACTURER'SGUIDELINESANDASDIRECTEDBYBUILDINGMANAGEMENTANDBUILDINGGUIDELINES.ALLOPENINGSINFLOORS, WALLSANDCEILINGSTHATCOULDLEADTODUSTESCAPINGTOOTHERAPARTMENTSORBUILDINGSPACESMUSTBESEALED. NEGATIVEAIRPRESSUREMACHINESREDUCEDUSTINFILTRATIONTOADJACENTUNITSANDPUBLICSPACESOUTSIDEOFTHEUNIT BEINGALTERED,PARTICULATEDUSTWITHINTHEWORKAREA,CLEANUPANDMAINTENANCETIME,ANDUNPLEASANTODORS. 25.THECONTRACTORISREQUIREDTOPROTECTALLPUBLICSTAIRWAYS/HALLWAYSPRIORTOSTARTOFDEMOLITIONUNTILALL ALTERATIONWORKISCOMPLETED. 26.G.CSHALLCONFIRMANDBERESPONSIBLETHATAFTERWORKHASBEENCOMPLETEDALLTHEEXISTINGANDNEWELECTRICAL EQUIPMENTSANDFIXTURES,INCLUDINGBUTNOTLIMITEDTO(APPLIANCES,HVACUNITS,AVEQUIPMENTS,ETC.)ARECONNECTED, FUNCTIONINGANDWORKING.
27.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTINGWALLANDFLOORSTHROUGHOUTAPARTMENT. 28.CONTRACTORSHALLSUPPLYCOORDINATEDSHOPDRAWINGSFORARCHITECTAPPROVALAT"=1'-0"INDICATINGTHEFOLLOWING: A)PARTITIONSB)LAYOUTOFLIGHTFIXTURES C)DUCTWORK,DIFFUSERSANDACCESSPANELSD)STRUCTURE
EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN
CEILING/ELECTRICNOTES:
1.THECONTRACTORSHALLVERIFYALLCONDITIONSFORCLEARANCEOFMECHANICALUNITS,DUCTWORK,PIPING,ETC,ANDNOTIFYTHEARCHITECTOF ANYDISCREPANCIESPRIORTOPROCEEDING.
2.REFERTOLIGHTFIXTURESCHEDULE&INSTALLINACCORDANCEWITHMANUFACTURER'SDIRECTIONS.
3.DIMENSIONSARETOTHECENTERLINEOFTHEFIXTURE,UNLESSOTHERWISENOTED.
4.VERIFYMAXIMUMACHIEVABLECEILINGHEIGHTSATTHEBEGINNINGOFCONSTRUCTIONANDNOTIFYARCHITECTIFANYCONDITIONSPREVENTTHE PROPOSEDHEIGHTSTOBECONSTRUCTED.ALLCEILINGHEIGHTSGIVENAREASSUMED,TOBEVERIFIEDONCEALLMECHANICALEQUIPMENTAND DUCTINGHAVEBEENINSTALLED.
5.ALLCEILINGHEIGHTSSHALLBEMEASUREDFROMTHEFINISHFLOORLEVELOFTHESPACEDESIGNATED.
6.PARTITIONSSHALLNOTBESECUREDORATTACHEDINANYWAYTODUCTWORK.
7.ALLSMOKEDETECTORS,DIFFUSERSANDGRILLESSHALLBECENTEREDAND/ORALIGNEDWITHSURROUNDINGARCHITECTURALELEMENTSU.O.N.
8.COORDINATELIGHTINGWITHENGINEER'SDRAWINGS,LUTRON'SSUBMITTALS&DECORATIVELIGHTINGSCHEDULE.
9.ALLCEILINGSSHALLBELEVELANDINALIGNMENT.PROVIDEFIRERATEDHOUSINGFORRECESSEDLIGHTSORPROTECTIVEFIRERATEDENCLOSURES. MAINTAINFIRERATINGOFCEILING.
10.COORDINATELIGHTFIXTURELAYOUTWITHLAYOUTOFPIPESANDEQUIPMENT.
11.PROVIDEBLOCKINGATALLHANGINGFIXTURELOCATIONS.
12.LIGHTFIXTURESINSMALLSPACES(I.E.CLOSETS,VESTIBULES,UTILITYROOMS,ETC.)SHALLBECENTEREDINTHESPACEUNLESSOTHERWISENOTED.
13.ALLHARDWIREDCARBONMONOXIDEDETECTORSSHALLCOMPLYWITHRS17-13ANDBEINSTALLEDINACCORDANCEWITH17-14&LL/2004. 14.REFLECTEDCEILINGPLANSAREFORCOORDINATIONPURPOSESONLYREFERTOENGINEERINGDRAWINGSFORLIGHTING,HVAC,SPRINKLER,ETC. 15.SUPPORTWIRESFORCEILINGMUSTNOTBECONNECTEDTOANYMECHANICAL,ELECTRICAL,PLUMBING,FIREPROTECTION,PIPINGANDEQUIPMENT.
16.WHERENOTED,WINDOWSTORECEIVEMOTORIZEDSHADESTOBECOORDINATEDWITHA.V.CONSULTANT. 17.G.C.'SELECTRICIANTOBERESPONSIBLEFORRUNNINGALLWIRINGFORALLSWITCHANDKEYPADLOCATIONS.COORDINATEWITHAVCONSULTANT INCLUDINGMOTORIZEDSHADESWITHBLACKOUTS.PROVIDEALLELEC.OUTLETSANDCABLE,HDMI,INTERNETOUTLETSATTVHEIGHTSASINDICATED. TVMOUNTINGHEIGHTSTOBEDETERMINEDWITHOWNER.PROVIDEREQUIREDFRAMINGANDBLOCKINGFORALLWALLHUNGTV'S.INSTALLOWNER SUPPLIEDBRACKETSANDTV'S.
SYMBOLLEGEND:
CHANDELIERPENDANTFIXTURE
SURFACEMOUNTEDCEILINGFIXTURE
WALLSCONCETYP.
WALLSCONCE@BATHROOM
WALLSCONCEEXTERIOR CLOSETLIGHTFIXTUREW/JAMBSWITCH
IN-GROUNDEXTERIORFIXTURE
RECESSEDLIGHT-ROUNDTRIM
RECESSEDLIGHTSQUARETRIMLESS
*NOTE:USEWATERPROOFHOUSINGANDTRIM
FORALLRECESSEDLIGHTSINWETAREAS
CLOSETSURFACEMOUNTEDFIXTURE
CLOSETLIGHTWALLMOUNTED
UNDERCABINET/STRIPLIGHT
EXTERIORWALLSCONCE EXT
EXTERIORFLOODLIGHT
POWERNOTES:
1.THECONTRACTORSHALLVERIFYALLCONDITIONSFORCLEARANCEOFMECHANICALUNITS,DUCTWORK,PIPING,ETC,ANDNOTIFYTHEARCHITECTOF ANYDISCREPANCIESPRIORTOPROCEEDING.
2.REFERTOLIGHTFIXTURESCHEDULE&INSTALLINACCORDANCEWITHMANUFACTURER'SDIRECTIONS.REFERTORCPFORLOCATIONS.
3.DIMENSIONSARETOTHECENTERLINEOFTHEFIXTURE,UNLESSOTHERWISENOTED.
4.SUPPORTWIRESFORCEILINGMUSTNOTBECONNECTEDTOANYMECHANICAL,ELECTRICAL,PLUMBING,FIREPROTECTION,PIPINGANDEQUIPMENT.
5.LOWVOLTAGEWIRINGANDEQUIPMENTTOBECOORDINATEDWITHTHEA.V.CONSULTANT.
6.WHERENOTED,WINDOWSTORECEIVEMOTORIZEDSHADESTOBECOORDINATEDWITHA.V.CONSULTANT.
7.G.C.'SELECTRICIANTOBERESPONSIBLEFORRUNNINGALLWIRINGFORALLSWITCHANDKEYPADLOCATIONS.COORDINATEWITHAVCONSULTANT INCLUDINGMOTORIZEDSHADESWITHBLACKOUTS.PROVIDEALLELEC.OUTLETSANDCABLE,HDMI,INTERNETOUTLETSATTVHEIGHTSASINDICATED. TVMOUNTINGHEIGHTSTOBEDETERMINEDWITHOWNER.PROVIDEREQUIREDFRAMINGANDBLOCKINGFORALLWALLHUNGTV'S.INSTALLOWNER SUPPLIEDBRACKETSANDTV'S.
8.ALLELEC.OUTLETSINWETAREASSHALLBEG.F.I.TYPEASREQUIREDBYELECTRICALCODEANDASPERPLAN.
9.ALLEXISTINGELECTRICALRECEPTACLESNOTAFFECTEDBYNEWCONSTRUCTIONSHALLREMAIN(UNLESSOTHERWISENOTED).
SYMBOLLEGEND:
*OUTLETSTOBE"SCREWLESS"ASPEROWNER
ELECTRICALOUTLETDUPLEX
KEYNOTES: ALLAPARTMENT P01 P02
NEWOWNER-SUPPLIEDTV/SONOSBARWITHIN CUSTOMBEDMILLWORKINLIFTCABINET.
10 P P P P P P P P
CURRENTEXISTINGFLOORISRAISED,NEWFLOOR OUTLETSTOUTILIZERAISEDFLOOR 03 DEDICATEDOUTLETSFORAPPLIANCESAS INDICATED. 04
PROVIDEELECTRICSOURCEFORNEWRADIANT HEATUNDERNEWSTONEFLOORASINDICATED. SEEFINISHFLOORFORAREAOFHEATEDFLOOR. 05
PLUGMOLDSINTEGRATEDUNDERDESK/ CABINETRY. 06
07DEDICATEDAVRACKLOCATIONFORAV&SHADE COMPONENTS.120V20AMPDEDICATEDOUTLET. 08DEDICATEDOUTLETFORBIDET
PIANOTOBEWIREDBACKTOSPEAKERS THROUGHSONOSPORTFORALTERNATIVE CONNECTION.
LITMIRRORFOGMIRRORINSHOWER.PROVIDE POWER.
PROVIDEPOWERANDSWITCHFORHEATING LIGHTABOVESHOWER. P11
PROVIDEPOWERANDSWITCHFOR ELECTROSTATICPRIVACYFILMONGLASS. P12
NEWOWNER-SUPPLIEDSONOS)POWERED SUBWOOFERWITHPOWERCABLESRUNBY ELECTRICIANASNEEDED. P13
P14NOTUSED.
NEWOWNER-SUPPLIEDPOWEREDSONOS SPEAKERSINTEGRATEDINCUSTOMMILLWORK WITHPOWERANDDATACABLESRUNBY ELECTRICIANASNEEDED. P15
P16PROVIDEPOWERFOROPTI-MYSTFIREPLACE.
-NEWELECTRICTHROUGHAPARTMENTASPERCODE. -ALLOUTLETSTOBEINTEGRATEDINBASEBOARD UNLESSOTHERWISEINDICATED. -ALLOUTLETSINKITCHENANDINBATHROOMSTOBE GFI -OUTLETSINBATHROOMPAINTEDTOMATCHWALL FINISH -ALLFLOOROUTLETSTOBEFLUSHWITHFINISHFLOOR
CABLELINE
ELECTRICALPANEL
INTERCOM-2CAT6 D IN-FLOORELECTRICALOUTLETSINGLE IN-FLOORELECTRICALOUTLETDUPLEX
DATA/INTERNET1CAT61RG6 (COORDINATEWITHAVCONSULTANT)
TV4CAT6WIRES TV SP
ELECTRICALOUTLET*QUAD. M MOTORFORSHADES(COORDINATEWITHAV CONSULTANT)
SPEAKER-1-16/4SPEAKERWIRE(COORDINATE WITHAVCONSULTANT)
WIFIACCESSPOINT
GENERALPLUMBINGNOTES:
ELECTRICALWORKWILLBEPERFORMEDBYANEWYORKCITYLICENSEDELECTRICIAN. 10.ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSORTENANTSSHALL REMAINTHROUGHOUT.ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,PROTECTDURING CONSTRUCTION.(ALLLOCATIONSOFPLUMBINGRISERSSHOWNONPLANSAREASSUMED,NOTVISIBLE ATTIMEOFFIELDSURVEY).EXPLOREANDVERIFYRISERLOCATION,IFANYSPACECANBEGAINED. 11.BRANCHPIPINGREPLACEMENTFORTHEKITCHENANDBATHROOM,NEWSHUTOFFVALVESFOREACH BRANCHLINEANDASHUTOFFVALVEATTHERISER;MECHANICALWATERHAMMERARRESTORS;SPRING LOADEDCHECKVALVESINTHEHOTANDCOLD-WATERPIPINGFROMTHERISERTEES;ANDREPLACING THEDRAINANDPLUMBINGVENTPIPING.ALLNEWANDEXISTINGVALVESSHALLHAVEAFIRERATED ACCESSPANEL.THENEWSHOWERMUSTHAVETHEDRAINANDTRAPINSTALLEDANDTHETOILETWILL REQUIREANEWLEADBEND.
12.PLEASEENSURETHATALLACCESSISMAINTAINEDTOALLSHUT-OFFVALVES,LOCALLYATEACH FIXTUREANDGENERALLY.ANYPIPINGINSULATIONDISTURBEDMUSTBERESTORED.
13.NEWBRANCHPIPINGISTOINCLUDEPROVIDINGNEWRISERSHUT-OFFVALVESAMINIMUMOF4ELBOW SWINGSTOALLOWFORVERTICALEXPANSIONAREREQUIREDBETWEENTHEHOTWATERRISERTAND SHUT-OFFVALVE.PROVIDEDIELECTRICUNIONSWITHAPPROPRIATEENDCONNECTIONSFORTHEPIPE MATERIALSINWHICHINSTALLED(SCREWED,SOLDERED,ORFLANGED)TOISOLATEDISSIMILARMETALS. SOFT-SEATED,SPRING-LOADEDSWINGCHECKVALVESARETOBEPROVIDEDONHOTANDCOLDWATER BRANCHLINESFOLLOWINGTHESHUT-OFFVALVES.ALLVALVESARETOBEMADEACCESSIBLEFOR SERVICING.BRANCHPIPINGISTOBEWRAPPEDWITHDURABLE,CONDENSATECONTROLLING, INSULATINGMATERIALANDSUPPORTEDWITHNON-REACTIVEMATERIALS.AMINIMUMCLEARDISTANCE OF2"ISREQUIREDBETWEENHOTANDCOLDWATERPIPESANDTHEREMUSTBENOMETAL-TO-METAL CONTACTBETWEENPIPING,CONDUIT,BX,ETC.AWATERHAMMERARRESTERISTOBEPROVIDEDATALL BRANCHLINESTHATFEEDSINKS,LAVATORIESANDWATERCLOSETS.ARRESTERSMUSTBEMADE ACCESSIBLEFORSERVICING(UNLESSTHEUNITHASALIFETIMEGUARANTEEI.E.SIOUXCHIEF)ANDARE TOBELOCATEDACCORDINGTOMANUFACTURER'SINSTRUCTIONS. 14.NEWBRANCHPLUMBINGPIPINGISTOBELOCATEDOUTBOARDOFALLRATEDDEMISINGPARTITIONS.
GRAPHICLEGEND:
SANITARYDNBRANCHLINE
SUPPLYHOTWATER&COLDWATERBRANCHLINE
VDNBRANCHLINE
PLUMBING-DIRECTIONOFSUPPLYDRAINLINES
PLUMBING-DIRECTIONOFGASLINES
AREAOFRAISEDFLOORFORPLUMBING.
WATERPROOFINGMEMBRANE
SEAMLESS,CONTINUOUSLEADPAN(6LBS./FT.) EXTENDED6"UPWALLS(CORNERSSOLDERED). FIFTEENPOUNDROOFINGFELTBETWEENPAN ANDCONCRETE.PLUGDRAINANDTESTFOR WATERTIGHTNESSFOR24HRS.COATPAN WITHASPHALTPAINTTOPREVENT ELECTROLYSISANDCORROSION. METALSTUD 5/8"CONCRETE BACKERBOARD LEADPAN THINSET MORTARBED LATICRETE9235 WATERPROOFINGMEMBRANE
LIGHTWEIGHTCONCRETEFILL 4" 2"
3B/P-101-STEAMUNITMEDICINECABINETDETAIL
LINEOFTOPEDGEOFLEADPANLINER12" ABOVEFLOORANDTOCEILINGAROUNDSHOWER
NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE. 5CONC.BACKERBOARD NEWSTONESLABONWALLS.
LIGHTWEIGHTCONCRETEORFIRERATEDFOAM FILLTOFORM&SHAPESHOWERBED
CEMENTBACKERBOARDASSACRIFICIALLAYER FORWATERPROOFMEMBRANE.KEMPER2K-PUR WATERPROOFMEMBRANERUNFULLHEIGHTIN BATHROOM
NEWSHOWERDRAINCONNECTEDTOEXISTING DRAINLINE.LIGHTWEIGHTCONCRETEFORINFILL.
LATICRETE'9235'WATERPROOFING/LATICRETE 'HYDROBAND'WATER-PROOFINGONSHOWER SURFACESANDWALLSUPTOCEILING.
KEMPER2K-PURWATERPROOFMEMBRANERUN FULLHEIGHTINBATHROOM&SHOWERON SACRIFICIALLAYER.
5B/P-101-BATHROOMSADDLEDETAIL
EXISTINGCONC.SLABTOREMAIN
BRACINGANDBLOCKINGASREQ'D.
FLEXIBLEFOAMBACKERROD&TILESEALANT EXPANSIONJOINT.
STEAMOUTLET WATERINLET
MANUALBALL-TYPESHUT-OFFVALVE
STUDFRAMINGWITHPIPING
BLOCKINGASREQ'D.
RECESSEDLIGHTFIXTURE
CEILINGTOBESLOPED2"PERFT.
TILEONTHINSETSLOPENINTOSTEAMSHOWER.
LATICRETE'9235'WATERPROOFING/LATICRETE 'HYDROBAND'WATER-PROOFINGONSHOWER SURFACESANDWALLSUPTOCEILING.
KEMPER2K-PURWATERPROOFMEMBRANERUN FULLHEIGHTINBATHROOM
LEAKDETECTORWITHAUDIBLEALARM LEADPANCOVEREDWITHLIQUIDWP MEMBRANE
VIBRATIONISOLATIONPAD
SOUNDMATUNDERLAYMENT. AUTOMATICSHUT-OFFVALVE
EXISTINGSLABWITHCEMENTBACKER BOARDASSACRIFICIALLAYERFOR WATERPROOFMEMBRANE.KEMPER 2K-PURWATERPROOFMEMBRANERUN FULLHEIGHTAROUNDSTEAMUNIT.
NOTE: 1.STEAMUNITINSTALLEDPERMANUFACTURERSSPECS 2.UNITTOBEINSTALLEDWITHINWATERPROOFPANW/ AUTOMATICSENSORALARMANDSHUT-OFF. 3.UNITMOUNTEDONVIBRATIONISOLATORS(MASON INDUSTRIESOREQUAL). 4.STEAMUNITTOBEACCESSIBLE.
2A/P-101-STEAMSHOWERCEILINGDETAIL
LINEOFTOPEDGEOFLEADPANLINER12" ABOVEFLOORANDTOCEILINGAROUNDSHOWER
NEWSTONESLABONSHOWERWALLSON THINSETBACKERBOARD.
LIGHTWEIGHTCONCRETEFILLOR FORM&SHAPESHOWERBED CEMENTBACKERBOARDASSACRIFICIALLAYER FORWATERPROOFMEMBRANE.KEMPER2K-PUR WATERPROOFMEMBRANERUNFULLHEIGHTIN BATHROOM NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE. "CONC.BACKERBOARD
EXISTINGCONC.SLABTOREMAIN
CRUSHEDGRAVELATWEEP HOLES.
NEWREINFORCEDMORTARBED SLOPEDTODRAIN1 4PERFT.
LIGHTWEIGHTCONCRETEOR FIRERATEDFOAMFILLTO FORM&SHAPESHOWERBED
NEWTILESONWALLS
LATICRETE'9235'WATERPROOFING/ LATICRETE'HYDROBAND'WATER-PROOFING RUNUPWALLSUPTO12"ABOVEFINFLOOR
5 8CONC.BACKERBOARD
NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE
CEMENTBACKERBOARDASSACRIFICIAL LAYERFORWATERPROOFMEMBRANE. KEMPER2K-PURWATERPROOFMEMBRANE RUNUPWALLSUPTO12"ABOVEFINFLOOR
EXISTINGCONCRETESLABTOREMAIN.
ALUMINUMANGLEATEDGEOF SADDLE. TURNUPWATERPROOFINGMEMBER 90DEGREES@DOORSADDLE NOTE: USEKEMPERCERTIFIEDINSTALLEDFORALLKEMPER INSTALLATION
NEWWALL-TO-WALL CARPET
GENIEMATRST-5 GLUEDTOFF-10.
GENIEMATFF-10 DIMPLEDMAT.
EXISTINGFINISHFLOOR TOREMAIN
EXISTINGCONCRETESLABTO REMAIN.NOCHANNELINGOR PENETRATIONPERMITTED.
NEWFLOORSLABONRAISEDFLOOR
LATICRETE'9235'WATERPROOFING/ LATICRETE'HYDROBAND'WATER-PROOFING RUNUPWALLSUPTO12"ABOVEFINFLOOR
5 8CONC.BACKERBOARD
NEWLEADPANCOATEDINLIQUID WATERPROOFINGMEMBRANE
KEMPER2K-PURWATERPROOFMEMBRANE RUNUPWALLSUPTO12"ABOVEFINFLOOR
CEMENTBACKERBOARDASSACRIFICIAL LAYERFORWATERPROOFMEMBRANE.
HAVECUSTOMMTL FINGERPULLS SEEDETAIL2/A-401
GLASSSHELVESW/ RECESSEDLIGHTS CLADWALLW/ STONE.ST-06.
RECESSEDMEDICINE CABINETBYGCW/ MATCHINGMIRRORS.
DMSELENESCONCES MOUNTEDONEITHER SIDEOFVANITY
CUSTOMVANITYBY GC.SEEA-406FOR DETAILS.
OWNERSUPPLIED MAKE-UPMIRROR
RAISEDTO ACCOMMODATE FREESTANDING TUBPLUMBING. SEEP-102.
GLASSTORECEIVE ELECTROSTATICPRIVACYFILM, WIREDBYELECTRICIAN. GLASSSPLITINTO3PIECES ALONGFILMLINE.
WHTLACQ.TOUCHLATCH
LEDLIGHTSUNDERCABINET
FLOATINGGLASSSHELVES
GLASSTORECEIVE ELECTROSTATIC PRIVACYFILM. SPLITINTO3PIECES ALONGPRIVACYFILM. DMSELENESCONCES MOUNTEDONEITHER
DMSELENESCONCES MOUNTEDONEITHER SIDEOFVANITY
WHITELACQUER LAUNDRYHAMPERW/ STONECOUNTERTOP
SHOWERRAISEDFLOORLEVELTO BEMINIMUMASDETERMINEDBY SITECONDITIONS
NICHE.DEPTH
TIGHTASPOSSIBLE.
SLIMCOLUMNADDED FOREXTRASUPPORT IFNEEDED.
LEFTSIDE CLOSETD RIGHTSIDE CLOSETD FRONTSIDE
RIGHTSIDE
RIGHTSIDE
SPEAKERSONPULLOUT DRAWERFORMAINTENANCE
CLOSETDOORTOSWINGAND LAYFLATAGAINSTWALL
SPEAKERSONPULLOUT DRAWERFORMAINTENANCE
CLOSETD
CLOSETC
CLOSETB
CLOSETA
SMOKEYGLASSDOORS
6&7A-3114&5
APPLIEDFABRICPANELONEXISTINGDOORS.
GRILLECOLORTBDBYAOR MTLWALLDETAILBELOW GRILLETOCONCEAL.
BATHROOM#3 (POWDERROOM)
BATHROOM#2(GUEST BATHROOM)
BATHROOM#1(HIS BATH)
BATHROOMFLOOR
SHOWERCEILING ST-8 HONED
SHOWERWALLS ST-8 HONED
VANITYCLADDING ST-8 HONED
BATHROOMFLOOR ST-1 HONED
SHOWERFLOOR ST-1 HONED
VANITYCOUNTERTOP
SHOWERWALLS ST-4 HONED
BATHROOMWALLS ST-4 HONED
SHOWERWALLS ST-3 HONED
VANITYCOUNTERTOP ST-3 HONED ANTI-ETCH
PRIMARYBATHROOM (HERBATH) BATHROOMFLOOR ST-3 HONED
VANITYCOUNTERTOP ST-3 HONED
DROPCEILING EXISTINGSTRUCTURE.
EXTENDWALLFINISHTO CONCEALPOCKETBEHIND. DROPCEILING EXISTINGSTRUCTURE. ALIGN ALIGN
4"WPOCKETFORDRAPERY RUNSTRAIGHTACROSSBAY WINDOWS.
EXTENDWALLFINISHTO CONCEALPOCKETBEHIND.
4"WPOCKETFORDRAPERY RUNSTRAIGHTACROSSBAY WINDOWS.
VARIESSEESCHED
ROUTEDPATTERN, PAINTED,SINGLESWING MDFDOOR. FLATONINSIDE.
SEESCHEDULEFORSIZE ANDFINISH.
ROUTEDPATTERN,PAINTED, SINGLESWINGMDFDOOR. WOODPATTERNONINSIDE. SEESCHEDULEFORSIZE ANDFINISH.
DOORELEVATIONS
TYPE'C'
ROUTEDPATTERN,PAINTED, POCKETMDFDOOR. FLATONINSIDE. SEESCHEDULEFORSIZE ANDFINISH. TYPE'B'
WOODBLOCKINGS
WALLTILE/SLABAS SPECIFIED
1"FABRICWRAPPED PLYWOODASSPECIFIED
5/8"TYPE'X'GYPBD BOTHSIDES(TYP)
WOODBLOCKINGS
WALLTILE/SLABAS SPECIFIED
WALLFINISHAS SPECIFIED
5/8"TYPE'X' GYPBDBOTH SIDES(TYP)
1"FABRICWRAPPEDPLYWOOD ASSPECIFIED
METALSTUDFRAMING WITHWOODSTIFFENER HAFELEHAWAJUNIOR80/Z TRACKSELFCLOSING MECH.SOFTMOVE80,WITH FLOORMOUNTEDDOOR GUIDES
5/8"TYPE'X'GYPBDBOTH SIDES(TYP) WOODBLOCKINGS
WALLSLABASSPECIFIED
SCHLUTERTRIM@SLAB EDGE
DOORDETAILSASPER SCHEDULE.
WALLTILE/SLABASSPECIFIED
5/8"TYPE'X'GYPBDBOTH SIDES(TYP)
METALSTUDFRAMING WITHWOODSTIFFENER
WALLFINISHASSPECIFIED
WOODBLOCKINGS
HAFELEHAWAJUNIOR80/Z TRACKSELFCLOSING MECH.SOFTMOVE80,WITH FLOORMOUNTEDDOOR GUIDES
DOORCASINGAS SPECIFIED
DOORDETAILSASPER SCHEDULE.
5/8"TYPE'X'GYPBDBOTH SIDES(TYP) METALSTUDFRAMING WITHWOODSTIFFENER
DOORCASINGAS SPECIFIED
DOORDETAILSASPER SCHEDULE. PROVIDEINSULATION(TYP) WALLFINISHASSPECIFIED 1"FABRICWRAPPED PLYWOODASSPECIFIED
5/8"TYPE'X'GYPBD BOTHSIDES(TYP) METALSTUDFRAMING WITHWOODSTIFFENER
WALLFINISHASSPECIFIED
DOORCASINGAS SPECIFIED
DOORDETAILSASPER SCHEDULE. 1"FABRICWRAPPED PLYWOODASSPECIFIED
NOTES: FRONTLEGSARESTRAIGHTANDTAPERED. BACKLEGSARECURVEDANDTAPERED. CENTERBACKLEGENDSATSEATHEIGHT.SIDE BACKLEGSEXTENDINTOTHEBACKSUPPORT
BATHROOMFLOOR RAISEDTO ACCOMMODATE
OWNER
ChrisKilgore Owner kilgore2014@gmail.com 215West78thStreet,Apt#1A,NewYorkNY,10024
RaquelTripp Owner rmatripp@gmail.com
MANAGEMENT FirstServiceResidentialEvelynStanczak PropertyManager evelyn.stanczak@fsresidential.com(212)851-8510 575FifthAvenue,NewYork,NY,10017
BUILDINGARCHITECT
ARCHITECTURE ArchetypeArchitecture
INTERIORDESIGNER
EXPEDITER NexusConsultingGroup NYC,Inc.
NatalieBeskrownyj AssistantPropertyManager natalie.beskrownyj@fsresidential.com(212)634-5493
Benny Superintendant (646)379-4900
AlanBerman,ArchitectA.O.R. Aberman@archetype-ny.com (212)580-6087 x101 2162Broadway,2ndFloor,NewYork,NY,10024
OmarKhalifa ProjectManager OKhalifa@archetype-ny.com x120
LaraSteiner ProjectManager LSteiner@archetype-ny.com x109
JimmyGhandi jimmy@nexusconsultingnyc.com (212)242-4926 x5 1PierrepointPlaza,12thFl,Brooklyn,NY11201
JacquelineMulinelli jacqueline@nexusconsultingnyc.com x4
ABERMAN@ARCHETYPE-NY.COM
COMMONABBREVIATIONS:
MASONRYOPENING MECHANICAL MEMBRANE MINIMUM MOLD&MOISTURERESISTANT METAL
NOTINCONTRACT NOMINAL NOTTOSCALE ONCENTER PRE-CASTCONCRETE PLUMBING PLYWOOD PRESSURETREATED PAINTED RUBBER
REFLECTEDCEILINGPLAN ROOFDRAIN REQUIRED ROOM ROUGHMASONRYOPENING SIMILAR
SEEMECHANICALDRAWINGS SLABONGRADE
SPECIFIEDORSPECIFICATION SPEAKER STAINLESSSTEEL
SEESTRUCTURALDRAWINGS
SOUNDTRANSMISSIONCOEFFICIENT STEEL
STRUCTUREORSTRUCTURAL TONGUEANDGROOVE
THERMOSTAT TELEPHONE TOILET TOPOF
TOPOFCONCRETE TOPOFSTEEL TOPOFWALL
TOILETPAPERDISPENSER
TELEPHONE/DATA
TYPICAL
UNLESSNOTEDOTHERWISE VERIFYINFIELD WITH WOOD WATERRESISTANTBARRIER
PLUMBINGTOBESUBMITTEDONSEPARATEDOBAPPLICATION
PLOTPLAN-NOTTOSCALE
CONTROLLEDINSPECTIONSREQUIREDFOR: PROGRESSINSPECTIONS: []FINALINSPECTION(DIRECTIVE14) []ENERGYCODECOMPLIANCE
ENERGYCODEINSPECTION: []LIGHTINGINDWELLINGUNITS. []LIGHTINGCONTROLS. INSPECTIONS
THISPROPERTYISNOTINA LANDMARKSDISTRICT
PROJECTFILEDUNDERNYC1968BUILDINGCODE
PROJECTINFORMATION:
215WEST78THST,APT.#1A NEWYORK,NY10024
EXISTINGHEIGHTSANDSETBACKSTOREMAIN.NOADDITIONAL BUILDINGAREAWILLBECONSTRUCTED.
BOROUGH: MANHATTAN BLOCK: 1170 LOT: 23 BIN: 1030906
MAPNO: 5D ZONING: R8B
COMMUNITYBOARD: 107
COMMERCIALOVERLAY: NONE
CONSTRUCTIONCLASS: CLASS1(1938CODE) FIREPROOFSTRUCTURE
OCCUPANCYCLASS: RESIDENTIAL(1938CODE)
MULTIPLEDWELLING
CLASSIFICATION: NL HEIGHT: 100 STORIES: 10
DWELLINGUNITES: 38
JOBDESCRIPTION:
ARCHITECTURALANDPLUMBING WORKFORINTERIORAPARTMENT RENOVATIONS.
NOCHANGEINUSE,EGRESSOROCCUPANCY
PROPERTYISNOTONS.F.H.A. (SPECIALFLOODHAZARDAREA)
1107.2.3.4COOKTOPSANDOVENS: COOKTOPSANDOVENSSHALLCOMPLYWITHSECTIONS1003.12.5.4AND1003.12.5.5OFICC A117.1,RESPECTIVELY.HOWEVER,OVENCONTROLSSHALLNOTBEREQUIREDTOBE LOCATEDONEITHERSIDEOFTHEOVENDOOR,PROVIDEDSUCHCONTROLSCOMPLYWITH SECTION1003.12.5.5.4OFICCA117.1.WHEREDOUBLEOVENSAREPROVIDED,ATLEASTONE OVENINTERIORANDITSCONTROLSSHALLCOMPLYWITHSECTION309.3(HEIGHT)OFICC A117.1.
1107.2.3.5KITCHENANDKITCHENETTESTORAGE: KITCHENSTORAGE,KITCHENCABINETS,DRAWERS,ANDSHELFSTORAGEAREAS,WITHIN KITCHENANDKITCHENETTESTHATAREREQUIREDTOCOMPLYWITHSECTION1003.12OFICC A117.1PURSUANTTOSECTION1107.2.3,EXCEPTOVERHEADCABINETS,SHALLCOMPLY WITHSECTION905(STORAGEFACILITIES)OFICCA117.1.INADDITION,ATLEASTONE STORAGESHELFORCABINET,MOUNTEDABOVEWORKCOUNTERSAT48INCHES(1219MM) MAXIMUMABOVE
EXCEPTION:WHERETHESTORAGESHELFORCABINETISNOTPROVIDEDINACCORDANCE WITHTHISSECTION,THEOWNERSHALLINSTALLSUCHSTORAGESHELFORCABINETIN COMPLIANCEWITHTHISSECTIONATTHETIMEPERSONWITHPHYSICALDISABILITIES TAKESOCCUPANCYOFTHEUNIT,ORWITHIN10DAYSOFTHEDATETHEREQUESTISMADE BYAPERSONWITHPHYSICALDISABILITIES,WHICHEVERISLATER,ATTHEOWNER'S EXPENSE.
1004.12KITCHENSANDKITCHENETTES: KITCHENSANDKITCHENETTESSHALLCOMPLYWITHSECTION1004.12.1004.12.1 CLEARANCE.CLEARANCECOMPLYINGWITHSECTION1004.12.1SHALLBEPROVIDED.
1004.12.1.1MINIMUMCLEARANCE: CLEARANCEBETWEENALLOPPOSINGBASECABINETS,COUNTERTOPS,APPLIANCES,OR WALLSWITHINKITCHENWORKAREASSHALLBE40INCHES(1015MM)MINIMUM. 1004.12.1.2U-SHAPEDKITCHENS.INKITCHENSWITHCOUNTERS,APPLIANCES,ORCABINETS ONTHREECONTIGUOUSSIDES,CLEARANCEBETWEENALLOPPOSINGBASECABINETS, COUNTERTOPS,APPLIANCES,ORWALLSWITHINKITCHENWORKAREASSHALLBE60INCHES (1525MM)MINIMUM.
1004.12.2CLEARFLOORSPACE: CLEARFLOORSPACEATAPPLIANCESSHALLCOMPLYWITHSECTIONS1004.12.2AND305.3. 1004.12.2.1SINK.ACLEARFLOORSPACE,POSITIONEDFORAPARALLELAPPROACHTOTHE SINK,SHALLBEPROVIDED.THECLEARFLOORSPACESHALLBECENTEREDONTHESINK BOWL.EXCEPTION:ASINKWITHAFORWARDAPPROACHCOMPLYINGWITHSECTION 1003.12.4.1.
1004.12.2.2DISHWASHER: ACLEARFLOORSPACE,POSITIONEDFORAPARALLELORFORWARDAPPROACHTOTHE DISHWASHER,SHALLBEPROVIDED.THEDISHWASHERDOORINTHEOPENPOSITIONSHALL
UNDERSIDEOF STRUCTUREABOVE.
7/8"FURRINGCHANNEL@16"OC
5/8"GYPSUMBOARDCEILING-PRIMED&PAINTED
SECTION
PLAN
ACCESSIBILITYNOTES:2014BCARTICLE11ACCESSIBILITY.ANSIA117.12009. 1107.2.2TYPEB+NYCUNITTOILETANDBATHINGROOMS WHERETOILETANDBATHINGROOMSAREPROVIDEDINTHETYPEB+NYCDWELLING UNITORSLEEPINGUNIT,ALLSUCHTOILETANDBATHINGROOMSSHALLCOMPLYWITH APPENDIXP.
EXCEPTIONFORTYPEATOILETANDBATHINGROOM: 1.0WHEREATLEASTONETOILETANDBATHINGROOMINTHETYPEB+NYC DWELLINGUNITORSLEEPINGUNITISCONSTRUCTEDINACCORDANCEWITHTHE TYPEATOILETANDBATHING FACILITIES REQUIREMENTSOFSECTION1003.11 (TOILETAND BATHINGFACILITIES),INCLUDINGSECTION1003.3.2(TURNING SPACE),OFICCA117.1ANDISINCOMPLIANCEWITHTHEFOLLOWING:
1.1ATLEASTONELAVATORY,ONEWATERCLOSETANDEITHERABATHTUBOR SHOWERWITHINSUCHTOILETORBATHINGFACILITYSHALLCOMPLY WITH SECTION1003.11OFICCA117.1.SUCHTOILETANDBATHINGFIXTURES SHALLBEINASINGLETOILETORBATHINGAREA,SUCHTHATTRAVEL BETWEENFIXTURESDOESNOTREQUIRETRAVELBEYONDTHEAREAINWHICH THEFIXTURESOFSUCHTOILETORBATHINGROOMARELOCATED.
1.2TOILETPAPERDISPENSERSWITHINSUCHROOMSSHALLCOMPLYWITH SECTION604.7(DISPENSERS)OFICCA117.1.
1.3MEDICINECABINETS,IFPROVIDED,MUSTINCLUDEASTORAGESHELFNO HIGHERTHAN44INCHES(1118MM)ABOVETHEFLOOR.
2.0WHEREATLEASTONETOILETANDBATHINGROOMCOMPLYINGWITHSECTIONS 1003.11AND1002.3.2OFICCA117.1ISPROVIDEDWITHINTHETYPEB+NYC DWELLINGUNITORSLEEPINGUNITINACCORDANCEWITHITEM1OFTHIS EXCEPTION,OTHERTOILETANDBATHINGROOMSINTHESAMEUNITSHALLBE REQUIREDTOCOMPLYONLYWITHSECTIONS 1004.3(ACCESSIBLEROUTE), 1004.4(WALKINGSURFACES),1004.5.2(USERPASSAGEDOORWAYS),1004.9 (OPERABLE PARTS)AND1004.11.1(GRABBARANDSHOWERSEAT REINFORCEMENT)OFICCA117.1.DOORSANDDOORWAYSTOSUCHTOILETAND BATHINGROOMSSHALLBESUBJECTTOSECTION1107.2.1,EXCEPTION5.
5/8"TYPE'X'GYPSUM BOARD-PRIMED& PAINTED
EXISTING DEMISINGWALL TOREMAIN
5/8"GYPSUMBOARD@BOTHSIDES-PRIMED& PAINTED
3-5/8"18GAUGEMETALSTUDS@16"O.C.
SOUNDATTENUATIONBATT INSULATIONBETWEENMETALSTUDS SEALANTATPERIMETER,TYP.
BASEASSCHEDULED
3-5/8"x18GAUGEMETALSTUDS@16"O.C.
5/8"GYPSUMBOARD @BOTHSIDES-PRIMED&PAINTED
SOUNDATTENUATIONBATTINSULATION BETWEENMETALSTUDS
A.GENERALDRYWALLPARTITION
SECTION
VARIES18GAUGEMETAL STUDS@16"O.C.
EXISTINGDEMISINGWALL
SOUNDATTENUATIONBATTINSULATIONBETWEEN METALSTUDS
3-5/8"x18GAUGEMETALSTUDS@16"O.C.
5/8"TYPE'X'GYPSUMBOARD-PRIMED&PAINTED
B.INTERIORWALLFURRING
3-1/2"METALSTUD
SOUND ATTENUATION BATTINSULATION PLAN B2
NEWFULLHEIGHTPARTITION 16GAUGEMETALSTUDS@16"O.C.WITHONELAYEROF5/8"TYPEXGYPSUMWALLBOARDONEACHSIDE,WITHSOUNDATTENUATION BATTINSULATIONBETWEENSTUDSUPTOCEILING. A1 NEWFULLHEIGHTPARTITIONFORWETAREAS: 3-1/2"16GAUGEMETALWALLSTUDS@16"O.C.WITHONELAYERTYPEXGYPSUMWALLBOARDONNON-WETSIDEANDONELAYER OFMOISTURERESISTANTCEMENTBOARDONWETSIDEFROMFLOORTOUNDERSIDEOFCEILINGABOVE.PROVIDEWOODBLOCKING TOSUPPORTCABINETRYANDBATHROOMACCESSORIES.
NEWFULLHEIGHTFURREDPARTITION "16GAUGEMETALSTUDS@16"O.C.WITHONELAYEROF5/8"TYPEXGYPSUMWALLBOARD,WITHSOUNDATTENUATIONBATT INSULATIONBETWEENSTUDSUPTOCEILING.
5MMSOUNDATTENUATION(TYP.) MINSTC/IIC62RATING
NEWWOODFLOORASSPECIFIED
PLYWOODUNERLAYMENT
SADDLEASSPECIFIED
FLOORTILESASSPECIFIED
MUDSETASREQUIREDFORFLOOR LEVELING.
5MMSOUNDATTENUATION(TYP.) MINSTC/IIC62RATING
CONTINUOUSKEMPER2KPUR WATERPROOFINGMEMBRANE. WATERPROOFINGSHALLBETURNEDUP ALONGSTEELANGLEAND12"ATALLWALLS INWETAREAS.
STEELANGLE
SOFFITDETAIL(Typical):
RAMSETPIN#SDC125C27CALIBER
EXISTINGUNDERSIDEOFCONCRETE CEILING
HILTIEYELET
EXISTINGUNDERSLABPLASTERCEILING
DIA.GALV.STEELPENCIL
ROD4'-0"O.C.MAX
2CARRYINGCHANNEL(BLACKIRON) .475#/LF4'-0"O.C.MAX.
GAT#131-68-5M
CADDYFASTENER
GAT#2815L
2FURRINGCHANNELCLIP
8METALFURRINGCHANNEL
2'-0"O.C.SCREWEDTOEDGEOFBLACKIRON 8SHEETROCK
XMINCONTINUOUS BLOCKINGCUTINTOSTUD
COVERPLATE (3)SCREWS 34TOCENTERLINEOF BLOCKINGTOFLOOR
MOUNTINGPLATE
WIC: -REMOVECLOSETDOORS,CLOSETWALLS,AND LIGHTS. -REMOVEEXISTINGDOORSASINDICATED. -EXISTINGRISERSTOREMAIN.PROTECTATALL TIMESDURINGDEMOLITION.REMOVEANY SURROUNDINGSHEETROCKORPLASTERWORK.
PRIMARYBEDROOM:
-REMOVEEXISTINGCEILINGLIGHT.
-REMOVEEXISTINGWALLSASINDICATED. -REMOVEEXISTINGDOORSASINDICATED.
HALFBATH:
-REMOVEEXISTINGTOILET.CAPANDRETURN EXISTINGPLUMBINGLINESBACKTORISER
NOTE: 1.EXISTINGCONDITIONSBASEDONSITEVISIT. PROBEASREQUIREDTOCONFIRMTHAT REMOVALDOESNOTAFFECTSTRUCTURAL, RISER,ORMECHANICALSYSTEMS.
2.NOCHIPPINGORCHANNELINGOFTHE EXISTINGBUILDINGSTRUCTUREISPERMITTED ATANYLOCATION.
GENERALREMOVALNOTES:
BATHROOM:
-EXISTINGTUBAPRONTOBEREMOVED.ALLTUB FIXTURESTOBEREMOVED.TUBTOREMAININ EXISTINGLOCATION.NOCHANGETODRAINAGE.
-EXISTINGFINISHESTOONLYBEREMOVED WHEREINDICATED. -PROTECTALLBATHROOMFIXTURESDURING DEMOLITION.
7.ANYEXISTINGUTILITYSERVICESTOBEREMOVED,
WALLSPRIORTOREMOVAL.PROVIDEALLNECESSARY SHORING,BRACING,ANDSUPPORTTOPREVENT MOVEMENT,SETTLEMENT,ORCOLLAPSEOF STRUCTUREORELEMENTTOBEDEMOLISHED,AND ADJACENTSTRUCTUREORELEMENTSHOWNTO REMAIN.
13.IFSOMETHINGINDICATEDONTHEPLANOR DISCOVEREDINTHEFIELDISNOTSPECIFICALLY IDENTIFIEDTOBEREMOVEDORTOREMAINONTHE PLANS,CONTRACTORSHALLREQUESTDIRECTION FROMARCHETYPEPRIORTOREMOVAL.
14.G.C.ISRESPONSIBLEFORTHETEMPORARYSHORING DESIGN.SUBMITDETAILSANDDESIGNCALCULATIONS BEARINGTHESEALOFALICENSEDPROFESSIONALOR STRUCTURALENGINEER'SREVIEWBEFORE CONSTRUCTIONOFSHORING.
15.SAFETYZONE:SAFETYZONESHALLBEPROVIDED AROUNDALLWORKAREASTOPREVENTPERSONS OTHERTHANWORKERSFROMENTERINGSUCHZONE. WHEREWORKOCCURSONTHEEXTERIOROFA BUILDING,SUCHZONESHALLBEAPPROVEDBYTHE COMMISSIONERPRIORTOTHECOMMENCEMENTOF WORK.
16.SEQUENCE:ANYSTRUCTURALMEMBERTHATISBEING DISMEMBEREDSHALLNOTSUPPORTANYLOADOTHER THANITSOWNWEIGHT.NOWALL,CHIMNEY,OR OTHERSTRUCTURALPARTSHALLBELEFTINSUCH CONDITIONTHATITMAYCOLLAPSEORBETOPPLEDBY WIND,VIBRATIONORANYOTHERCAUSE.THEMETHOD OFREMOVALOFANYSTRUCTURALMEMBERSHALL
KITCHEN:
-REMOVEEXISTINGCOMBINATION WASHER-DRYER.
-REMOVEDISHWASHER,TOBERELOCATEDIN NEWLOCATION,SEECONSTRUCTIONPLANFOR LOCATION.
-REMOVEEXISTINGPENINSULACOUNTERTOP. KITCHENCABINETRYTOREMAIN.
ENTIREAPARTMENT:
-REMOVEEXISTINGELECTRICALOUTLETS THROUGHOUTENTIREAPARTMENTASREQUIRED, TOBEREPLACEWITHNEWPERCODE.
-REMOVEEXISTINGLIGHTFIXTURES THROUGHOUTAPARTMENTASINDICATED.TOBE REPLACEWITHNEW.SEERCPPLANFOR LOCATION.
HALLWAYFOYER:
-REMOVEEXISTINGWOODFLOOR. -REMOVEEXISTINGBASEBOARDASNEEDED.
BEDROOM2:
-REMOVEEXISTINGWOODENWINDOWSCREENS. -REMOVEEXISTINGSCONCES.
BEDROOMDINING:
-REMOVEEXISTINGWOODENWINDOWSCREENS. -REMOVEEXISTINGSCONCES.
ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMS ORTENANTSSHALLREMAINTHROUGHOUT(PLUMBING,ELECTRICALAND DOORBELLRISERS).
ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,PROTECTDURING DEMOLITIONANDCONSTRUCTION.(ALLLOCATIONSOFPLUMBINGRISERSSHOWNON PLANSAREASSUMED,NOTVISIBLEATTIMEOFFIELDSURVEY.)VERIFYALLEXISTING SHUTOFF/CHECKVALVESLOCATIONSINTHEENTIREAPARTMENT.COORDINATEBRANCH REPLACEMENT,REPAIR&RELOCATIONWITHBLDGSUPER.REPLACEALLACCESS PANELS(MIN.12"X12")ATALLPLUMBINGRISERLOCATIONSTHROUGHOUTPER BUILDINGREQUIREMENTS.COORDINATEWORKWITHBLDGPLUMBER&BLDG.SUPER.
IFSOMETHINGINDICATEDONTHEPLANORDISCOVEREDINTHEFIELDISNOT SPECIFICALLYIDENTIFIEDTOBEREMOVEDORTOREMAINONTHEPLANS,CONTRACTOR SHALLREQUESTDIRECTIONFROMARCHETYPEPRIORTOREMOVAL.
MAINTAINFIRERATINGOFSHAFTWALLSANDCOLUMNORBEAMENCLOSURES. PROTECTATALLTIMESDURINGCONSTRUCTION.RESTOREASNECESSARY.
EXISTINGCONCRETECEILINGANDFLOORSTOREMAIN.NOCHANNELINGOFEXISTING STRUCTURALCONCRETEALLOWED.CHIPDOWNNON-STRUCTURALCONCRETETOPPING INFUTUREKITCHENSOFLOORSCANBELEVEL.
ALLEXISTINGWINDOWSTOREMAIN.G.C.TOPROTECTATALLTIMESDURING DEMOLITION.
REMOVEEXISTINGSWITCHES,OUTLETSANDELECTRICALLINESINPARTITIONSTOBE DEMOLISHEDANDTHROUGHASINDICATED.SEEELECTRICALPLANFORNEWLAYOUT. REMOVEALLEXISTINGILLEGALSURFACEMOUNTEDCONDUITOREXPOSEDELECTRICAL LINESTHROUGHOUT
UPGRADEELECTRICALPANELSASNECESSARY.ALLWORKTOBEDONEBYALICENSED ELECTRICIAN.COORDINATEWORKWITHBUILDINGSUPERINTENDENTANDARCHETYPE PRIORTOJOBSTARTUP.CONTRACTORTOCONFIRMTHATEXISTINGLOADWILLBE ADEQUATEFORTHEPROPOSEDWORKANDNOTIFYARCHITECT.
REMOVEEXISTINGCLOSETINTERIORSYSTEMS,HANGINGPOLESAND/ORSHELVESIN ALLCLOSETS.PREPARECLOSETAREASTORECEIVENEWFINISHES.
BATHROOMPROTECTALLFINISHESTOREMAININEXISTINGBATHROOM.PROTECTALL BATHROOMFIXTURESTOREMAIN.
REMOVEINTERIORDOORSANDDOORFRAMESASNOTEDONDRAWINGS.REFERTODOOR SCHEDULEONSHEETA-300.00FORMOREINFORMATION.
EXISTINGORIGINALWOODFLOORSTOREMAINTHROUGHOUT.PROTECTATALLTIMES DURINGDEMOLITIONANDCONSTRUCTION.SALVAGEEXISTINGWOODFLOORFORPATCHING EXISTINGFLOORS.
2162Broadway,2ndFL
PHONE:212.580.6087
ABERMAN@ARCHETYPE-NY.COM
ALANBERMANRAAIA NYSLIC.036223
STRUCTURALENGINEER: MECHANICALENGINEER:
NOTDESTABILIZEREMAININGMEMBERS.ALL HANDLINGANDMOVEMENTOFMATERIALORDEBRIS SHALLBECONTROLLEDSUCHTHATITWILLNOT DEVELOPUNACCOUNTEDIMPACTLOADSONTHE STRUCTURE.
17.NOSTRUCTURALMEMBERSTOBEMODIFIEDINANY WAY
GRAPHICLEGEND: CONCRETEMASONRYUNIT(CMU)WALL
CONCRETECONSTRUCTION
EXISTINGBUILDINGSTRUCTURE,WALLSOR ELEMENTSTOREMAIN
EXISTINGINTERIORWALLSORELEMENTSTOBE REMOVED
NOTE:ALLWALLS&PARTITIONSBEINGREMOVEDARENOT LOADBEARING.
EXITINGCONDITIONSBASEDONSITEVISIT.PROBEASREQ'D TOCONFIRMTHATREMOVALDOESNOTAFFECTSTRUCTURAL, RISERS,ORMECHANICALSYSTEMS.
BATHROOM2: -NEWPOCKETDOORANDDOORFRAMEFORNEW BATHROOM -EXISTINGRISERSTOREMAIN.PROTECTATALL TIMESDURINGCONSTRUCTION.
-NEWWALLANDFLOORTILE.PATTERNTOBE CONFIRMEDBYCLIENT.
-NEWTOILET,NEWSINKVANITYINNEW LOCATION.SEESPECSSUPPLIEDBYCLIENT.
-EXISTINGTUBTOREMAININEXISTINGLOCATION. NEWTILEDAPRON.
PRIMARYBEDROOM:
2.ANYBREACHESINFIRE-RATEDSHAFTWALLS TOBEREPAIRED/REPLACEDATTHEENDOF EACHWORKDAY.
LAUNDRY:
-NEWSUPPLYANDRETURNLINEFORNEW, ELECTRIC,STACKED,VENTLESSWASHER/DRYER ININDICATEDLOCATION.REFERTOG-003FOR DETAILS.
BATHROOM: -EXISTINGTOILET&SHOWERFIXTURESTOREMAININ EXISTINGLOCATION.PROTECTATALLTIMESDURING CONSTRUCTION. -NEWVANITYANDSINK -ANYTILEDWALLSNOTPARTOFDEMOLITIONTOBE PROTECTEDDURINGCONSTRUCTION.NEWWALLTILETO MATCHEXISTINGATNEWWALL. -ADDGRILLATTOPOFFWALLFORPASSIVEVENTILATION
GENERALCONSTRUCTIONNOTES:
16.PROVIDENEWLATICRETE#9235WATERPROOFMEMBRANE&SOUNDMATTINGBELOW OVERENTIREKITCHENLAUNDRYANDBATHROOMAREAS,TURNEDUP12"ATWALLASPER DETAILSINSHEET#G-003.
17.SUPPLY&INSTALLALLCONSTRUCTIONMATERIALSINCLUDINGBUTNOTLIMITEDTOPAINT, SPACKLE,GLUE,FLOORINGCOMPOUNDS,GROUT,SWITCHES,OUTLETS,DIMMERS,CONDUIT AND/ORSPECIALWIRINGASREQUIRED.
PROTECTDURINGCONSTRUCTION.(ALLLOCATIONSOFPLUMBINGRISERSSHOWNON PLANSAREASSUMED,NOTVISIBLEATTIMEOFFIELDSURVEY).EXPLOREANDVERIFYRISER LOCATION,IFANYSPACECANBEGAINED. 27.PLUMBINGWORKSHALLBEDONEBYLICENSEDNYCPLUMBERWHOSHALLARRANGEFOR ANDOBTAINALLREQUIREDDOBPERMITS,INSPECTIONSANDSIGN-OFFS.ALLPLUMBING WORKSHALLCOMPLYWITHTHENYCPLUMBINGCODE.
18.SUPPLY&INSTALLNEWCUSTOMBASEMOLDINGS,PICTUREMOLDINGSANDDOORCASING MOLDINGSTHROUGHOUTENTIREAPARTMENTASSHOWNINPLANS.DYKESOREQUAL.
19.PROVIDENEWSHUT-OFFVALVES@FIXTURES&RISERS@ALLNEWPLUMBINGLOCATIONS. PROVIDEACCESSPANELSASREQUIRED. 20.WHERENEWPLUMBINGFIXTURESAREINSTALLEDORBRANCHPIPINGOTHERWISEEXPOSED (INCLUDINGSTEAM,VENT&DRAINLINES),THECONTRACTORSHALLREPLACEFROMTHE FIXTURETOTHEBUILDING'SRISERSANDSTACKS,ANDREPLACELOCALRISERSHUT-OFF VALVESASMAYBEREQUIRED.
21.GENERALCONTRACTORSHALLBERESPONSIBLETOFAMILIARIZEHIMSELFWITHTHE LOCATIONSOFALLWATERSHUT-OFFVALVESCONTROLLINGTHEWATERINTHELOCATION OFWORK.GCSHALLDELEGATESOMEONEONSITEORHAVEINFORMATIONREADILY AVAILABLETHATWILLALLOWFORTHEIMMEDIATEWATERSHUTOFFSYSTEMSSHOULDAN UNFORESEENWATERFLOWNEEDTOBECONTAINED.
22.NOCHANNELINGOFANYSTRUCTURALSLAB,DEMISINGWALLSANDEXTERIORWALLSOR PIPECHASE/SHAFTENCLOSUREWALLSWILLBEPERMITTEDDURINGTHECOURSEOFANY WORK.
23.NOOFFSETOFRISERS(PLUMBING,GAS,ETC)WILLBEPERMITTED.
24.ALLPLUMBINGWORKWILLBEPERFORMEDBYANEWYORKCITYLICENSEDPLUMBERAND ALLELECTRICALWORKWILLBEPERFORMEDBYANEWYORKCITYLICENSEDELECTRICIAN. ALLREQUIREDPERMITSSHALLBEOBTAINED.
25.G.CSHALLCONFIRMANDBERESPONSIBLETHATAFTERWORKHASBEENCOMPLETEDALL THEEXISTINGANDNEWELECTRICALEQUIPMENTSANDFIXTURES,INCLUDINGBUTNOT LIMITEDTO(APPLIANCES,HVACUNITS,AVEQUIPMENTS,ETC.)ARECONNECTED, FUNCTIONINGANDWORKING.
26.ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSORTENANTS SHALLREMAINTHROUGHOUT.ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,
KITCHEN:
-NEWLINEFOREXISTINGDISHWASHERINNEW LOCATION.
-EXISTINGREFRIGERATOR,SINK,MICROWAVE& RANGETOREMAININEXISTINGLOCATIONS.TO BEPROTECTEDATALLTIMESDURING CONSTRUCTION.
-NEWCOUNTERTOPFORKITCHENISLAND.
ENTIREAPARTMENT:
-EXISTINGWALLSTOBEPATCHED.ENTIRE APARTMENTTOGETPLASTERANDPAINT.
-BASEBOARD&CROWNMOLDINGTHROUGHOUT ENTIREAPARTMENTTOREMAINUNLESS DISTURBED.NEWFINISHCARPENTRYTOMATCH EXISTING.
-ALLEXISTINGWINDOWSTOREMAIN.PROTECT ATALLTIMESDURINGCONSTRUCTION.
-SANDANDREPAINTEXISTINGWOODWINDOW SILLSANDINNERMOLDINGS.TYPICAL.
-NEWBARSTOBEINSTALLEDINSIDEALL WINDOWWELL.
HALLWAYFOYERLIVINGROOM:
-EXISTINGSTRUCTURALCOLUMNTOBEPROTECTEDAT ALLTIMESDURINGCONSTRUCTION.TOBEFINISHEDTO MATCHSURROUNDINGWALLS.
CONSTRUCTIONKEYNOTES
ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSOR TENANTSSHALLREMAINTHROUGHOUT(PLUMBING,ELECTRICAL,INTERCOMAND DOORBELLRISERS).PROTECTRISERSDURINGDEMOLITIONANDCONSTRUCTION. ALLLOCATIONSOFPLUMBINGRISERSSHOWNONPLANSAREASSUMED,NOT VISIBLEATTIMEOFFIELDSURVEY.
VERIFYALLEXISTINGSHUTOFF/CHECKVALVESLOCATIONSINTHEENTIRE APARTMENT.COORDINATEREPLACEMENT,REPAIR&RELOCATIONWITHSUPER. COORDINATEWORKWITHBUILDINGSUPERINTENDENT.
IFSOMETHINGINDICATEDONTHEPLANORDISCOVEREDINTHEFIELDISNOT SPECIFICALLYIDENTIFIEDTOBEREMOVEDORTOREMAINONTHEPLANS, CONTRACTORSHALLREQUESTDIRECTIONFROMARCHETYPEPRIORTOREMOVAL.
MAINTAINFIRERATINGOFSHAFTWALLSANDCOLUMNORBEAMENCLOSURES. PROTECTATALLTIMESDURINGCONSTRUCTION.RESTOREDAMAGEDAREAS.
A05
BATHROOMS:G.C.TOINSTALLALLNEWOWNERSUPPLIEDFIXTURESANDFINISHES SUCHASTOILET,SHOWERCONTROLS,FLOORSTANDINGVANITYUNITTOBE INSTALLEDBYG.C.,LAVATORY/SINK,DECKMOUNTEDFAUCET,RECESSEDMOUNTED MEDICINECABINET,CEILINGLIGHTFIXTURES&WALLSCONCES.INSTALLNEW OWNERSUPPLIEDFLOOR,WALLFIELDTILESANDALLOWNERSUPPLIED ACCESSORIES.SEESEPARATEMATERIALS,FIXTURES&FINISHESSPECIFICATIONS.
A06 SKIMCOATALLWALLSANDCEILINGSTHROUGHOUT.PATCHCRACKS,OPENINGS, IMPERFECTIONS,ETC.APPLYPRIMERAND(2)COATSOFPAINTTOALLWALLSAND MOLDINGSTHROUGHOUT.PROVIDEALLOWANCEFORFIVE(5)'BENJAMINMOORE' PAINTCOLORS.
SUPPLYANDINSTALLALLNEW1"THICK,SOLIDCOREPAINTGRADE(POPLAR) WOODDOORSANDFRAMES.INSTALLEDOWNERPROVIDEDANDHARDWARE.G.C. TOCOORDINATEWITHARCHETYPETHEHINGESANDHARDWAREBEFOREG.C. PURCHASETHEDOORS.WITHNEWHINGESTHROUGHOUT.INSTALLNEWOWNER SUPPLIEDDOORLEVERS&DOORSTOPSTHROUGHOUT.SUPPLYANDINSTALLNEW INTERIORDOORSASPERPLAN.
A08
BEDROOM2: -NEWBARSTOBEINSTALLEDINSIDEALLWINDOW WELL.
-NEWLIGHTFIXTURES.SEEA-800FORMORE INFORMATION
BEDROOMDINING:
-NEWBARSTOBEINSTALLEDINSIDEALLWINDOW WELL.
-NEWLIGHTFIXTURES.SEEA-800FORMORE INFORMATION
EXISTINGORIGINALWOODFLOORSTOREMAINTHROUGHOUT.PATCHANDREPAIR ANDFEATHERINNEWWOODFLOORINGANDREDOBORDERSWHEREWALLSHAVE BEENREMOVED.PROVIDEANDINSTALLNEWSHOEMOLDINGSWHEREBASEBOARD HAVEBEENREMOVED. FORAREASTORECEIVENEWWOODFLOORS:SUPPLYANDINSTALLNEWWOOD FLOORINGINSTRAIGHTRUNPATTERNMATCHEXISTINGINSIZE,SPECIESANDCOLOR. INSTALL3/4"PLYWOODSUBFLOORWITHSOUNDATTENUATION.SANDFLOORS THROUGHOUT,APPLY(2-3)NEWSTAINCOATSAND(2-3)POLY-URETHANECOATS (WATERBASEDONLY)MINIMUMUNTILFINALMATCHINGSTAINISACHIEVED.CLIENT TOAPPROVESTAINSAMPLESPRIORTOFINALAPPLICATION.PROVIDEANDAPPLY3 STAINSAMPLES,FORCLIENT'SAPPROVAL.
PHONE:212.580.6087
ABERMAN@ARCHETYPE-NY.COM
ALANBERMANRAAIA NYSLIC.036223
STRUCTURALENGINEER: MECHANICALENGINEER:
28.THEBUILDINGSTRUCTURE,INCLUDINGSTEELCOLUMNS,STEELBEAMSANDCONCRETE FLOORSLABSANDFIREPROOFINGATTACHEDTHERETO,SHALLNOTBEDISTURBEDINANY WAY.FLOORSLABSSHALLNOTBECHOPPED,CHANNELEDORCORED.THISINCLUDESTHE FLOORSURFACE(TOPOFSLAB)ANDTHECEILINGSURFACE(BOTTOMOFSLAB). FIREPROOFING,WHETHERFOUNDTOBEDAMAGEDORMISSINGORDAMAGEDDURING CONSTRUCTIONSHALLBEREPAIREDTOPROVIDETHEREQUIREDFIRE-RESISTANCERATINGS. 29.OPENINGS/GRILLESINTOVENTILATIONSHAFTSORPLUMBINGCHASESMUSTBESEALED WHILEWORKISBEINGDONESOTHATNODUST,DIRT,OROTHERTYPEOFNUISANCECAN AFFECTOTHERAPARTMENTSORCOMMONAREAS.
EXISTINGBUILDINGSTRUCTURE, WALLSORELEMENTSTOREMAIN EXISTINGINTERIORWALLSOR ELEMENTSTOBEREMOVED
PLUMBINGFIXTURETAGAPPLIANCE/EQUIPMENTTAGREFERTOSCHEDULE P-
REFERTOSCHEDULE
EXISTING(2)HOURRATEDWALL T THERMOSTAT(LUTRONOREQUAL) NEWCONSTRUCTION
GRAPHICLEGEND: DOORTAG-REFERTOSCHEDULE
SMOKE/CARBONMONOXIDEDETECTORASPER RS-1713/14ALSOTOCOMPLYWITHLL7/04
ELECTRICALPANEL
PARTITIONSCHEDULE:
ALLINTERIORPARTITIONS&FURRINGTOHAVEFULL HEIGHTSOUNDBATTS.QUIETROCKASNOTED.
NEWFULLHEIGHTPARTITIONPROVIDE2"OR316GAUGEMETALSTUDS@16"O.C. WITHONELAYEROF5/8"TYPEXGYPSUMWALLBOARDONEACHSIDE,WITHSOUND ATTENUATIONBATTINSULATIONBETWEENSTUDSUPTOCEILING. A A1 NEWFULLHEIGHTPARTITIONFORWETAREAS: 2OR31 216GAUGEMETALWALLSTUDS@16"O.C.WITHONELAYER8TYPEX GYPSUMWALLBOARDONNON-WETSIDEWITHSOUNDATTENUATIONBATTINSULATION BETWEENSTUDSUPTOCEILINGANDONELAYEROF5MOISTURERESISTANTCEMENT BOARDONWETSIDEFROMFLOORTOUNDERSIDEOFCEILINGABOVE.PROVIDEWOOD BLOCKINGTOSUPPORTCABINETRYANDBATHROOMACCESSORIES.
C NEWHRRATEDPARTITION:UL#U411 PROVIDE31/2"16GA.METALSTUDS@16"O.C.WITHTWO(2)LAYERSOF5 8TYPEX GYPSUMWALLBOARDONEACHSIDEW/SOUNDATTENUATIONBATTINSULATION BETWEENSTUDSUPTOCEILING. B NEWFURREDOUTWALL: 116GAUGEMETALWALLSTUDS@16"O.C.W/SOUNDATTENUATIONBATT INSULATIONUPTOCEILING.USE5/8"MOISTURERESISTANTGYPSUM/CEMENTBOARDON
NEWTILEAPRON TILEPATTERNN.I.C.CLIENTTO CONFIRMPATTERN
EXISTINGBATHTUBTOREMAIN
F.B.O.NEWWALLTILE LEPATTERNNCCLENT TOCONFIRMPATTERN
F.B.O.NEWTOILET
INTERIORSNOTES:
6.
FINISHDROPCEILING
F.B.O.NEWWALLTILE
TILEPATTERNN.I.C.
CLIENTTOCONFIRM PATTERN
NEWF.B.O.MIRRORED MEDICINECABINET NEWF.B.O.TOWELRACK CLIENTTOCONFIRMSIZE ANDLOCATION
F.B.O.NEWWALLTILE TLEPATTERNNCCLE TOCONFIRMPATTERN NEWPOCKETDOOR NEWFBOSNKANDVA
NCSTORAGEBYOTHE
NEWTILEAPRON
(EXISTINGBATHTUBTO REMAINBEHIND)
F.B.O.NEWTILE
TLEPATTERNNCCLE TOCONFIRMPATTERN
2162Broadway,2ndFL NEWYORK,NY10024
NEWGRILLFOR
F.B.O.NEWWALLTILE TLEPATTERNNCCLEN TOCONFIRMPATTERN
NEWTILEAPRON (EXISTINGBATHTUBTO REMAINBEHIND)
F.B.O.NEWTILE TLEPATTERNNCCLEN TOCONFIRMPATTERN
GCTOINSTALLALLF.B.O. PLUMBINGFIXTURES CLIENTTOCONFIRMSHOWER HEADTYPEANDACCESSORIES
NEWPARTITIONWALL
EXISTINGBATHTUBTOREMAIN
NEWTILEAPRON TILEPATTERNN.I.C.CLIENTTO CONFIRMPATTERN
F.B.O.NEWLIGHT FIXTURETYPEAND LOCATIONTOBE CONFIRMEDBY CLIENT
FINISHDROPCEILING ELEV.9'-0"V.I.F.
F.B.O.NEWWALLTILE
TILEPATTERNN.I.C.
CLIENTTOCONFIRM PATTERN
F.B.O.NEWMIRRORED MEDICINECABINET
F.B.O.NEWSINK, FAUCETANDVANITY
F.B.O.NEWTOILET
ALLEXISTINGBUILDINGLINESTHATAREINUSEBYOTHERBUILDINGSYSTEMSORTENANTSSHALL REMAINTHROUGHOUT.ALLEXISTINGPLUMBINGRISERSTOREMAINTHROUGHOUT,PROTECT DURINGCONSTRUCTION.ALLLOCATIONSOFPLUMBINGRISERSSHOWNONPLANSAREASSUMED, NOTVISIBLEATTIMEOFFIELDSURVEY.G.C.TOVERIFYACTUALLOCATIONONSITEDURING DEMOLITION.
G.C.TOINSTALLNEWSHOWERHEAD&CONTROLSONNEWROUGH-INS F.B.O.-FURNISHEDBYOWNER,INSTALLEDBYCONTRACTOR
G.C.TOSUPPLYANDAPPLY(2)COATSOFPAINTTOCEILINGANDWALLS.ALLOWFOR(2)BENJAMIN MOOREPAINTCOLORS.COORDINATEPAINTCOLORWITHOWNERS
G.C.TOINSTALLALLNEWOWNERSUPPLIEDFLOORTILES.PROVIDEWATERPROOFMEMBRANE OVERENTIREBATHROOMAREATURNEDUP12"ATWALLS.
G.C.TOINSTALLALLNEWOWNERSUPPLIEDACCENTTILES.
G.C.TOINSTALLNEWOWNERSUPPLIEDMARBLESADDLEATMOSTABOVEFINISHEDFLOOR.NEW BATHROOMFLOORTOMATCHHEIGHTOFNEWWOODFLOORINRESTOFAPARTMENT.PROVIDENEW SELFLEVELINGCONCRETEASREQUIRED.
G.C.TOINSTALLVANITYCABINETWITHOWNERSUPPLIEDLAVATORY/SINK,ANDFAUCETG.C.TO SUPPLYANDINSTALLPLYWOODWALLSUPPORTS.CONFIRMWITHCLIENTMATERIALS,FIXTURES& FINISHESSPECIFICATIONS
G.C.TOINSTALLNEWOWNERSUPPLIEDMEDICINECABINET.CONFIRMHEIGHTW/OWNER.CONFIRM FIXTUREANDFINISHESSPECSWITHOWNER.VERIFYAREABEHINDWALL.INSTALLPER MANUFACTURER'SRECOMMENDATIONS.PROVIDEADEQUATESUPPORTBEHINDWALLS& COORDINATEINSTALLATIONWITHVENDORANDARCHETYPE.
G.C.TOINSTALLNEWOWNERSUPPLIEDSHOWERHEAD,PLUMBINGFITTINGS,ANDCONTROLS.SEE SEPARATEFIXTUREANDFINISHESSPEC.CONFIRMSHOWERHEADANDHANDHELDSHOWERHEIGHT W/CLIENT.
G.C.TOINSTALLALLNEWOWNERSUPPLIEDACCESSORIESTHROUGHOUT.PROVIDEADEQUATE PLYWOODBLOCKINGWITHINWALLS.
G.C.TOSUPPLYANDINSTALLNEWGFCIELECTRICALOUTLETSWITHSTANDARDWHITESCREWLESS COVERPLATESTOCOMPLYWITHCURRENTNECELECTRICALCODES.
VERIFYEXISTINGSHUTOFFVALVESLOCATIONSTHROUGHOUTENTIREAPT.COORDINATEREPLACEMENT, REPAIR&RELOCATIONWITHSUPER.PROVIDE/REPLACERECESSEDACCESSPANELS,ASNEEDED.
G.C.TOINSTALLNEWOWNERSUPPLIEDSURFACEMOUNTEDLIGHTFIXTURESANDWALLSCONCES.
G.C.TOPROVIDEANDINSTALLNEWLUTRONSWITCHESONDIMMERSWITHNEWSNAPONTYPE WHITECOVERPLATES.SEEPLANSANDELEVATIONSFORSPECIFICHEIGHTS.
3.MANUFACTURER:'TRUSTILE'ORAPPROVEDEQUAL.
NOTE:
1.THISDRAWINGSHALLBEREADINCONJUNCTIONWITHARCHETYPE'SAND
2.FORDOORSWING(LEFTORRIGHTHINGED)SEEFLOORPLANSHEETA-001.
3.VERIFYINFIELDFOREXACT/ACCURATEDIMENSIONS(HEIGHTANDWIDTH)WHEN PERTAININGTOALLNEWANDEXISTINGOPENING.
DOORTYPES:
GENERALFINISHNOTES:
1.ALLWORKSHALLBEINACCORDANCEWITHALLSTATEANDLOCALCODES.
2.COORDINATE&SUPERVISEALLTRADESANDPROVIDETHEDESIGNATEDCLEARANCESSHOWNONTHESEDOCUMENTS.G.C.SHALLINFORMARCHETYPEPRIORTOPROCEEDING WITHWORKTHATDIFFERSFROMTHEDESIGNINTENT.
3.ALLDIMENSIONSARETOBETAKENFROMFACEOFFINISHEDGYP.BOARDUNLESSOTHERWISEINDICATED.
4.PREPAREALLSURFACESFORFINISHESPERMANUFACTURERSPECIFICATIONS.
5.SAND&APPLY(2)COATSOFCLEARPOLYURETHANETONEWWOODFLOORSTHROUGHOUTENTIREAPARTMENT.FLOORSTOBEPROTECTEDDURINGCONSTRUCTIONAS REQUIRED.USEWATERBASEDPOLYURETHANEONLY,ASREQUIREDBYBUILDING.
6.SEALALLPENETRATIONSTHROUGHALLFLOORS,WALLS&DOORS&ALLREDUCINGSTRIPSWHERECHANGESINFLOORFINISHESOCCUR.SUBMITSAMPLESFORAPPROVALTO ARCHETYPE.
7.SUPPLYALLCONSTRUCTIONMATERIALSINCLUDINGBUTNOTLIMITEDTOPAINT,SPACKLE,GLUE,FLOORINGCOMPOUNDS,GROUT,SWITCHES,CONDUITAND/ORSPECIALWIRING ASREQUIRED.
8.PROVIDESOUNDATTENUATION&INSULATIONLAYERINSIDEALLNEWANDEXISTINGFLOORSANDWALLSTHROUGHOUT.
9.FLASH,PATCHANDLEVELTHEFLOORSASREQUIREDFORNEWFLOORFINISHES.ALLFLOORFINISHESMUSTBEATTHESAMEFINISHELEVATIONUNLESSNOTEDOTHERWISE. NOTIFYARCHETYPEIFTHISCANNOTBEACHIEVEDSOTHATANYDETAILSCANBEMODIFIEDACCORDINGLY.
10.FLOORINGTOEXTENDUNDERMILLWORKANDAPPLIANCES(TYPICAL).
11.NSTALLNEWOWNERSUPPLIEDSTONE/TILEFLOOR.PROVIDE&INSTALLNEWSOUNDPROOFUNDERLAYMENTASREQUIREDBYBUILDINGMANAGEMENT.PROVIDEANDINSTALL NEWWATERPROOFINGMEMBRANEOVERENTIREFLOORAREATURNEDUP6"ATWALLS,REFERTOSHEETG-003.
12.GCTOPROVIDE&INSTALLNEWWOODSADDLES.NEWSTONESADDLESPROVIDEDBYOWNER,INSTALLEDBYCONTRACTOR.METALTRANSITIONSTRIPSASNOTED.
13.CONTRACTORTOSUPPLYANDINSTALLNEWPLYWOODSUB-FLOORSATALLAREASTORECEIVENEWFINISHFLOOR.PROVIDENEWSOUNDUNDERLAYMENTREFILLFLOORSWITH FLYASHASREQUIRED.CONFIRMWITHARCHETYPETHATALLFLOORSCANBEMADETOTHESAMELEVELPRIORTOINSTALLATION.
14.CONTRACTORTOFEATHERINNEWWOODFLOORINGTOMATCHWHEREWALLSHAVEBEENREMOVED.LEVELWITHEXISTINGFLOOR&SPOTSTAINTOMATCHEXISTING
NOTES:
1.THISDRAWINGSHALLBEREADINCONJUNCTIONWITHARCHETYPE'SANDCLIENT'SMATERIALS,FIXTURESANDFINISHES SPECIFICATIONS,DOORHARDWAREANDALLDETAILEDPLANSANDDRAWINGS.
GENERALDOORNOTES:
1.PROVIDE&INSTALLNEWSOLIDCORE"MEDIUMHARDWOOD"PAINTGRADEDOORSANDSTANDARD2"DOORCASINGSTHROUGHOUT ASSHOWNINPLANS&ASPERDOORSCHEDULEDOORSSHALLBEFREEOFKNOTS.
2.PROVIDE&INSTALLNEWHINGESTHROUGHOUT.(QUANTITY:3PERDOOR)
3.ALLNEWDOORSTOBESANDEDANDPAINTED/STAINEDTHOROUGHLY.COLOR&FINISHTOBEDETERMINEDATLATERDATE.
4.DOORSSHALLBEFREEOFKNOTS.
5.INSTALLALLOWNERSUPPLIEDWALLORFLOORDOORSTOPSTHROUGHOUT.
6.DOORMANUFACTURERTOBETRUSTILEORAPPROVEDEQUAL.
7.2.PURCHASEANDINSTALLALLITEMSINTHEDOORSCHEDULEANDDOORTYPES&DETAILEDJAMBANDHEADSECTION.VERIFYIN FIELDFOREXACT/ACCURATEDIMENSIONSWHENPERTAININGTOANEXISTINGOPENING.
8.INSTALLNEWHARDWARETHROUGHOUT.
9.PROVIDEANDINSTALLNEWSTONESADDLESTHROUGHOUTASINDICATEDINSCHEDULEABOVE.STONESADDLESSHALLBE STRAIGHT-CUTWITH4BEVELATBOTHSIDES.STONESHALLBEMARBLEOREQUAL,SUBMITSAMPLETOARCHETYPEFORAPPROVAL.
10.DOORS:GENERALSHALLMEETTHEREQUIREMENTSOFTHEBUILDINGCODE&CURRENTEDITIONOFTHELIFESAFETYCODE.
NOTES:
1.THISDRAWINGSHALLBEREADINCONJUNCTIONWITHARCHETYPE'SANDCLIENT'SMATERIALS,FIXTURESANDFINISHES SPECIFICATIONS,DOORHARDWAREANDALLDETAILEDPLANSANDDRAWINGS.
2.VERIFYINFIELDFOREXACT/ACCURATEDIMENSIONS(HEIGHTANDWIDTH)WHENPERTAININGTOALLNEWANDEXISTING OPENINGS.
HARDWARENOTES:
1.PROVIDE&INSTALLNEWHARDWARE. MANUFACTURER:TBD FINISH: TBD.
ABERMAN@ARCHETYPE-NY.COM
STRUCTURALENGINEER: MECHANICALENGINEER:
BATHROOM: -ANYNEWBATHROOMOUTLETSTOBEGFI -NEWBATHROOMLIGHTFIXTURES BATHROOM2:
PRIMARYBEDROOM: -NEWCLOSETLIGHTFIXTURESAINDICATED. -NEWCEILINGFIXTURE
NOTE: 1.NOCHIPPINGORCHANNELINGINTOEXISTING STRUCTUREFORRECESSEDLIGHTS.
2.NOTRENCHINGOFSTRUCTURALSLABSHALL BEDONEATANYLOCATION.
1.THECONTRACTORSHALLVERIFYALLCONDITIONSFORCLEARANCEOFMECHANICALUNITS,DUCTWORK,PIPING,ETC,ANDNOTIFYTHEARCHITECTOF ANYDISCREPANCIESPRIORTOPROCEEDING.
2.THECONTRACTORSHALLSUBMITCOORDINATEDSHOPDRAWINGSFORARCHITECTAPPROVALAT3/8"=1'-0"INDICATINGTHEFOLLOWING: A.)PARTITIONSB.)LAYOUTOFLIGHTFIXTURESC.)DUCTWORK,DIFFUSERSANDACCESSPANELSD.)STRUCTURE
3.REFERTOLIGHTFIXTURESCHEDULE&INSTALLINACCORDANCEWITHMANUFACTURER'SDIRECTIONS.
4.DIMENSIONSARETOTHECENTERLINEOFTHEFIXTURE,UNLESSOTHERWISENOTED.
5.VERIFYMAXIMUMACHIEVABLECEILINGHEIGHTSATTHEBEGINNINGOFCONSTRUCTIONANDNOTIFYARCHITECTIFANYCONDITIONSPREVENTTHE PROPOSEDHEIGHTSTOBECONSTRUCTED.ALLCEILINGHEIGHTSGIVENAREASSUMED,TOBEVERIFIEDONCEALLMECHANICALEQUIPMENTAND DUCTINGHAVEBEENINSTALLED.
7.ALLCEILINGHEIGHTSSHALLBEMEASUREDFROMTHEFINISHFLOORLEVELOFTHESPACEDESIGNATED.
8.PARTITIONSSHALLNOTBESECUREDORATTACHEDINANYWAYTODUCTWORK.
9.ALLSMOKEDETECTORS,DIFFUSERSANDGRILLESSHALLBECENTEREDAND/ORALIGNEDWITHSURROUNDINGARCHITECTURALELEMENTSU.O.N.
11.ALLCEILINGSSHALLBELEVELANDINALIGNMENT.PROVIDEFIRERATEDHOUSINGFORRECESSEDLIGHTSORPROTECTIVEFIRERATEDENCLOSURES. MAINTAINFIRERATINGOFCEILING.
12.COORDINATELIGHTFIXTURELAYOUTWITHLAYOUTOFPIPESANDEQUIPMENT.
13.PROVIDEBLOCKINGATALLHANGINGFIXTURELOCATIONS.
14.LIGHTFIXTURESINSMALLSPACES(I.E.CLOSETS,VESTIBULES,UTILITYROOMS,ETC.)SHALLBECENTEREDINTHESPACEUNLESSOTHERWISENOTED. 15.ALLHARDWIREDCARBONMONOXIDEDETECTORSSHALLCOMPLYWITHRS17-13ANDBEINSTALLEDINACCORDANCEWITH17-14&LL/2004.
16.REFLECTEDCEILINGPLANSAREFORCOORDINATIONPURPOSESONLYREFERTOENGINEERINGDRAWINGSFORLIGHTING,HVAC,SPRINKLER,ETC.
ENTIREAPARTMENT: -NEWOUTLETSANDELECTRICALWIRING THROUGHOUTAPARTMENTTOCOMPLYWITH 2020NYCECCC.LOCATIONSASINDICATEDON PLAN. KITCHEN: -ANYNEWKITCHENOUTLETSTOBEGFI -PROVIDEDEDICATEDOUTLETANDCIRCUITFOR NEWDISHWASHER -NEWCEILINGFIXTURE
BEDROOM2: -NEWCLOSETLIGHTFIXTUREASINDICATED.
BEDROOMDINING: -NEWBARSTOBEINSTALLEDINSIDEALLWINDOW WELL. -NEWLIGHTFIXTURES.SEEA-800FORMORE INFORMATION
BUILDINGSPECIFICNOTES:
1.ALLELECTRICALWORKMUSTBEPERFORMEDBYALICENSEDELECTRICIAN,WHOSHALLARRANGEFORANDOBTAINALLREQUIREDPERMITS, INSPECTIONS,ANDSIGN-OFFSTHROUGHTHEDOBBUREAUOFELECTRICALCONTROL.
2.DUPLEXOUTLETSINKITCHENANDBATHROOMSARETOBEGFCITYPE.DRAWINGSMUSTINDICATEGFCIAND/ORAFCIASAPPROPRIATEPROTECTION FORALLNEWGENERALPURPOSERECEPTACLEBRANCHCIRCUITSNYCELECTRICALCODE210.12,ANDTHATALLGENERALPURPOSERECEPTACLES SHALLBETAMPERRESISTANTTYPEASREQUIREDBYNYCELECTRICALCODE406.11.
3.ALLABANDONEDELECTRICALBOXESWITHREMAININGWIRINGENTERINGORLEAVINGSHALLREMAINACCESSIBLEWITHREMOVABLECOVERS.
4.THEELECTRICPANELANDINTERCOMPANELCANNOTBERE-LOCATEDWITHOUTSPECIFICWRITTENAPPROVAL.
5.ALLRECEPTACLE,SWITCH,ORLAMPHOLDERBOXESSHALLBESETFLUSHTOFINALFINISHEDSURFACE.EXTENDEXISTINGBOXESASNECESSARYOR UTILIZEPLASTERRINGSOROTHERDEVICESTOENSURETHATACONTINUOUSGROUNDEDMETALLICSURFACEISINPLACEBETWEENBOXESAND FACEPLATES.
6.NOCHOPPINGOFTHESLABORDEMISINGWALLSWILLBEPERMITTED.NEWWIRINGINWALLSMAYONLYBECONCEALEDWITHINTHEDEPTHOFTHE EXISTINGPLASTER,BEHINDMOLDINGS,ORCONCEALEDWITHINDRYWALLFURRING.WIRINGTOCEILINGFIXTURESMUSTBECONCEALEDINCONDULET ORADROPPEDCEILING.
7.IFPROPOSEDADDITIONALELECTRICALFIXTURESREQUIRENEWCIRCUITS,THEYMUSTBEPROVIDEDSOTHATTHEREISNOOVERLOADTOTHEMAIN CIRCUITOFTHEAPARTMENTAND/ORTHATOFTHEBUILDING.APANELSCHEDULESHOWINGRATINGSOFPANEL,NUMBEROFCIRCUITS,RATINGOF CIRCUITS,LOADS,ANDALLGFCIANDAFCICIRCUITBREAKERSMUSTBESUBMITTED.
SYMBOLLEGEND:
CHANDELIERPENDANTFIXTURE
SURFACEMOUNTEDCEILINGFIXTURE
WALLSCONCETYP.
CLOSETLIGHTFIXTUREW/JAMBSWITCH
NEWCONDUIT
SUPPLYANDINSTALLNEWELECTRICALPANEL,TOCOMPLYWITHNEC2011CODEAS AMENDEDBYNYC.
SUPPLYANDINSTALLNEWSMARTDIMMERS,FORALLSWITCHESWITHSTANDARDWHITE COVERPLATESANDDECORATIVEFACEPLATESSTANDARDWHITEBY"LUTON"TYPE THROUGHOUT.
COORDINATEWITHARCHETYPE,G.C.TOPROVIDEDIMMERSTHATARECOMPATIBLEWITH OWNERSUPPLIEDLIGHTFIXTURES.
SUPPLYANDINSTALLNEWALLNEWELECTRICALOUTLETSTOCOMPLYWITHNEC2011 CODEASAMENDEDBYNYC.CONFIRMALLLOCATIONSTOBEFURREDOUT.
PROVIDE&INSTALLNEWWIRINGINSIDEWALLSFORSWITCHESANDOUTLETSASNEEDED. PLASTER,PATCH,SANDANDSKIMCOATWALLSANDCEILINGSTHROUGHOUTWHERE ELECTRICALLINESHAVEBEENMODIFIED.
PROVIDECEILINGDROPSTOACCOMMODATECEILINGLIGHTS&CONDUITSASINDICATED. NOCHIPPINGOFEXISTINGCEILINGISPERMITTEDBYTHEBUILDING.COORDINATEWITHG.C. FORFINALCEILINGHEIGHTS.
INSTALLALLNEWOWNERSUPPLIEDCEILINGMOUNTED&RECESSEDLIGHTFIXTURES, WALLSCONCES,SURFACEMOUNTEDLIGHTS,UNDERCABINETLIGHTSTHROUGHOUT APARTMENT,ALLLIGHTSTOBEONDIMMERSCOMPATIBLETOOWNERSELECTEDLIGHTS. REFERTOARCHETYPE'SSEPARATESPECSFORALLAPPLIANCESANDLIGHTINGFIXTURES. PROVIDEACCESSIBLELOCATIONFORTRANSFORMERS.
SUPPLYANDINSTALLNEWELECTRICAL,PHONE,INTERNET/DATAANDCABLEOUTLETS THROUGHOUTASINDICATED.VERIFYMOUNTINGHEIGHTSWITHOWNER.
TOSUPPLYANDINSTALLALLDEDICATEDCABLE,INTERNET,HDMIANDELECTRICAL OUTLETSFORWALLHUNGTVLOCATIONSASINDICATED.G.C.TOSUPPLYANDRUNHDMI WIRES.VERIFYTVMOUNTINGHEIGHTWITHOWNER.PROVIDEPLYWOODBLOCKINGAS NECESSARY.PROVIDECABLERUN,INTERNETANDQUADOUTLETATAVCLOSETASSHOWN.
RELOCATEINTERCOMBACKTOORIGINALLOCATION
SUPPLY&INSTALLNEWHARDWIREDSMOKE&CARBONMONOXIDEDETECTORSASSHOWN ONPLANSANDINACCORDANCEWITHCURRENTCODECOMPLIANCE.
SUPPLY&INSTALLANDWIREFORNEWDEDICATEDA/COUTLETSASREQUIREDBYCODE. G.C.TOCOORDINATEWITHOWNER'SACSPECIFICATIONSFOROUTLETSLOCATIONS.
SUPPLY&INSTALLNEWDEDICATEDELECTRICALGFI&CONVENIENCEOUTLETS THROUGHOUTKITCHEN&BATHROOMSINCLUDINGNEWWASHERANDDRYERATLAUNDRY CLOSETASSHOWNONPLANSANDASPERAPPLIANCESMANUFACTURER'S RECOMMENDATIONS.EXISTINGELECTRICALOUTLETSSHALLREPLACEDTOCOMPLYWITH CURRENTELECTRICALCODE.
SUPPLYANDINSTALLALLNEWSWITCHESFORALLCLOSETLIGHTS.
*OUTLETSTOBE"SCREWLESS"ASPEROWNER
ELECTRICALOUTLET*-QUAD.
ELECTRICALOUTLET-DUPLEX
D SD S IN-FLOORELECTRICALOUTLET-QUAD. IN-FLOORELECTRICALOUTLET-DUPLEX
ELECTRICALPANEL
SDCO SMOKE/CARBONMONOXIDE DETECTORASPERRS-1713/14 ALSOTOCOMPLYWITHLL7/04
ELECTRICALOUTLET-CONNECTTOSWITCH S WPELECTRICALOUTLET-WATERPROOF(EXTERIOR)
DATAINTERNET-1CAT6/1RG6 (COORDINATEWITHAVCONSULTANT) TV-4CAT6WIRES TV
LINEOFCIRCUIT SWITCH J.S. CABLELINE
*NOTE:USEWATERPROOFHOUSINGANDTRIM FORALLRECESSEDLIGHTSINWETAREAS WALLSCONCE@BATHROOM J.S THREE-WAYSWITCH S3
EXHAUSTFANREFERTOMEP SPECIFICATIONS
DIMMERSWITCH(COORD.WITH AVCONSULTANT)
ELECTRICJAMBSWITCH@ALL CLOSETS(U.O.N.)
INTERCOM2CAT6
LAUNDRY:
BATHROOM: -EXISTINGBATHROOMVANITY,TOILETANDSHOWERTO REMAIN. BATHROOM2: -NEWLINESFROMFIXTURESTOTHERISERS RUNNINGINSIDEFURRED-OUTWALLS -BATHTUBTOREMAININSAMELOCATIONSEE BATH&SHOWERDETAILSONG-003.NEW
8.PLUMBERMUSTCHECKEXISTINGWASTEANDVENTLINESTOBEFREEOFOBSTRUCTION. 9.WATERSUPPLYNOTESORDIAGRAMSMUSTINDICATEBACKFLOWPREVENTIONDEVICESON ALLHARD-PIPEDFIXTURESANDAPPLIANCES.THISAPPLIESTOREFRIGERATORICEMAKER (IFANY)ANDDISHWASHER.
10.CHECKVALVESMUSTBEFURNISHEDONBRANCHPIPINGFORHOTANDCOLDWATER SUPPLYADJACENTTOMASTERSHUT-OFFVALVES.CHECKVALVESMUSTBEQUIETTYPE.
11.ALLHOTANDCOLDWATERPIPINGISTOBEINSULATED,MINIMUM½"THICKNESS.THIS INCLUDESEXISTINGLINESFOUNDTOBEUNINSULATEDDURINGDEMOLITION.
12.ALLHOTANDCOLDWATERPIPINGATFIXTURESISTOBETERMINATEDWITHAIRCHAMBERS (WATERHAMMERARRESTORS)RISINGABOVETHEFIXTURE.
13.FIXTUREPIPINGBETWEENSHUT-OFFVALVEANDTHEFAUCETORAPPLICATIONTOBE COPPERTUBINGWITHFLAREDENDSANDBRASSBUSHINGS.(NOPLASTIC,RUBBER,OR BRAIDEDSTAINLESSSTEEL.)
14.NOREINFORCEDRUBBERHOSEWILLBEALLOWEDINPIPINGTOFIXTURESANDAPPLIANCES. HIGHPRESSURE"NOBURST"BRAIDEDSTAINLESSSTEELWILLBEALLOWEDTOHOOKUP FIXTURESANDAPPLIANCESTHATDONOTHAVEACCESSAFTERINSTALLATIONIF DEMONSTRATEDTHEREISNOPRACTICALALTERNATIVE.
15.DISHWASHERDRAINMUSTEITHERHAVEALOOPRISINGTOUNDERSIDEOFCOUNTERTOP FLOODLEVELRIMOFTHESINKORABACKFLOWPREVENTIONDEVICE.THISMUSTBESHOWN ONRISERDIAGRAMORBYANAPPROPRIATENOTE.
16.ITMUSTBEVERIFIEDWHETHERREFRIGERATORHASANICEMAKERORWATERDISPENSER.IF SO,THEPIPINGMUSTBERUNABOVETHEFLOOR.TUBINGTOREFRIGERATORMUSTBE CONFIGUREDINALOOPBACKTOAVALVEANDTHENADRAIN,SOTHATTHELOWVOLUME FEEDMAYBEFLUSHEDOUTASNECESSARY.INSTALLATIONMUSTBEOBSERVEDBY BUILDINGSUPERINTENDENT.
17.WALLHUNGTOILETSWILLBEALLOWEDONLYWITHFULLHEIGHTWALLCARRIERS,FLOOR TOSLABABOVE,WITHINSULATIONPACKEDINTHEENTIREPIPECHASETOMINIMIZENOISE TRANSMISSION.CONCEALEDTANKMUSTBEWATERPROOFEDTOCEILING.DETAILSMUSTBE PROVIDED,INCLUDINGCONNECTIONTOWASTESTACK.
11.PROVIDENEWMASTERSHUT-OFFVALVESANDBRANCHLINESFORHOTANDCOLDWATER SUPPLYFORRE-HABBEDBATHROOMSANDKITCHEN.ALLVALVESMUSTBEFULLPORT,OF USMANUFACTURE.ALLNEWCOPPERPIPINGFROMTHEMASTERSHUT-OFFVALVETOEACH
FIXTURE.PROVIDENEWSHUT-OFFVALVESATEACHFIXTURE,ASFOLLOWS:
11.1.BATHROOM HOTWATERMASTERSHUT-OFFVALVE COLDWATERMASTERSHUT-OFFVALVE HOTWATERSHUT-OFFVALVEATLAVATORY COLDWATERSHUT-OFFVALVEATLAVATORY SHOWERVALVE(TEMPERATURERANGE110ºFTO120ºF) COLDWATERSHUT-OFFVALVETOTOILET
11.2.KITCHEN COLDWATERSHUT-OFFVALVE HOTWATERSHUT-OFFVALVE CHECKVALVEFORREFRIGERATORANDDISHWASHERSUPPLY
12.WHENEVERRADIATORSAREREMOVED,REPLACED,ORRELOCATED,BRANCHPIPINGMUST BEREPLACEDBACKTOTHERISERS.
13.BUILT-INCABINETSCONCEALINGRADIATORS,CONVECTORS,THRU-WALLUNITS,ANDFAN COILUNITSMUSTBEEASILYREMOVEDFORPROPERSERVICEANDMAINTENANCEOFUNITS, VALVES,ANDPIPING.
14.BATHROOMTILINGONCEILINGSWILLNOTBEALLOWEDWHEREITWOULDPREVENTACCESS TOOVERHEADPIPING.
15.NOGASPIPINGCHANGESAREINDICATEDANDNONEWILLBEALLOWEDASAPARTOFTHIS ALTERATION.
ENTIREAPARTMENT: -EXISTINGRADIATORSTOREMAIN