ANEX
A
FACADE D E S I G N O R G E S T T A F A C O L L E C T I O N
Portfolio
IN DE X
FACADE SYSTEMS *01-New Thermal Facade Systems
07
*02-Curtain Wall
08
*03-Glass Structural Facade System
09
WINDOWS AND DOORS SYSTEMS *04-Windows - Thermal Opening System
11
*05-Folding System
12
*06-Lift and Slide System
13
*07-Aluminum Composite Panel (ACP)
14
A TECH
GLASS FACADE SYSTEM
PROJECT
FACADE DESIGN
SYSTEM DATE WORK COUNTRY
Thermal March, 2015 everest group italy
TECH
Softwere: Auto cad, 3dmax, In Design, Photoshop, Illustrator
4
03 NEW THERMAL GLASS FACADE SYSTEM
5
02 CURTAIN WALL
C002EB
C004AS
30103
C003AS
30103
C003AS
C001EB
50
C010EB C005MS
30301
C002PB
C003EB
30411
Performance
C016SS
C003EB
C014AS
C001EB C010EB C005MS
30301 30411 C002PB
6
C004AS
50
1.1 Air permeability. The facade will be at least air permeability class AE750, EN 12152 Curtain walling - Air permeability Performance and requirements. System features must be certified by a laboratory test conducted according to the test method of the UNI EN 12153 Curtain walling. 1.2 Water tightness. The facade will be at least of class RE750 water resistance according to the UNI EN 12154 Curtain walling - Waterproofing- Performance requirements and classification. 1.3 Wind resistance. The curtain wall , tested in the laboratory using the method in standard EN 12179 Curtain Walls - Wind resistance Test method , must be able to withstand adequately the wind pressure of the project ( service load ) , applied both in pressure and vacuum , and must be able to transfer fully such action to the structure load-bearing of the building by means of appropriate anchor links. The wind load of the projectshould be in accordance with applicable national law and under this action the maximum elastic deformation ( measured at right angles to the facade plane ) of the frame members , will not be greater than 1/200 of the measured distance between two successive points of constraint to the building structure and in any case not exceed the limit of 15 mm , in accordance with EN 13116-indicators of the glass facade.
C002EB
01 GLASS STRUCTURAL FACADE SYSTEM
C003EB
C015AS
30103
C003AS
30103
C003AS
C002PB
20
C008EB
C006PB
C006SS
C002EB
Performance
7
C016SS
C014AS
C002EB C015AS
C008EB C002PB
20
C006SS
C003EB C006PB
1.4 Thermal insulation. The curtain wall must have overall average thermal transmittance U, not more than 2.2 W /m2K calculated according to the procedure specified by prEN 13947 Curtain walling - Calculation of thermal transmittance - Simplified method. 1.5 Monitoring of water vapor permeability The facade, and each individual parts, its fixed part and openable, must be designed and built in such a way as to ensure the control of the water vapor permeability, in order to avoid the possible formation of interstitial and surface condensation. 1.6 Resistance to permanent and accidental loads The curtain wall must be designed and built to support its own weight in addition to any other accidental vertical load provided by the design. These loads must be transferred completely to the load-bearing structure of the building by the facade constraints. The maximum elastic deformation (measured in the facade plane) of the horizontal elements of the frame under the action of vertical loads must not exceed 1/500 of the free light of inflection and in any case be less than 3 mm.The curtain wall must be designed and built to support in an appropriate manner a horizontal accidental load applied to a 1.20 m height. From the floor and a load of ... .KN / m (calculated specifically in accordance with what is stated in the prospectus 5.1 of Circular No. 4 July 1996 156AA.GG.STC Instructions for the technical standards concerning the “General criteria for verifying safety of constructions, loads and overloads “of the Ministerial decree of 16 January 1996) .
34
5
100
B TECH
WINDOWS AND DOORS SYSTEMS
PROJECT
WINDOWS AND DOORS
SYSTEM DATE WORK COUNTRY
Thermal September, 2015 everest group albania
TECH
Softwere: Auto cad, 3dmax, In Design, Photoshop, Illustrator
8
04 THERMAL OPENING SYSTEM DOORS/WINDOWS
Perdorimi i xhamave termike per te ulur pershkueshmerine termike. The use of thermal glass to reduce permeable thermal.
Pikaq xhami termik; Izolues per te kontrolluar kondesimin e brendshem. Glazing for thermal glass ; Insulating to control condensation of Indoors .
Lamaqe metalike ose plastike EPDM per hidroizolim dhe izolim termik.
Window
and thermal insulation .
High sound insulation even when the window is open a new solution for an issue that at first appears irresolvable – the thermal system CE 70 000 with perimetral mechanism ARX. A double panel window with the same structural and physical values of a double skin façade. This new type of window combines an inward opening sash with a parallel projecting sash. Both can be operated independently. This construction multiplies the user comfort in many ways: individual ventilation, and automatic control for night cooling assure the best possible room climate. A sun protection device integrated between both sashes not only ensures even greater comfort, it also reduces energy consumption.
normatives UNI EN 573/3 (EN-AW-6060) UNI EN 573/3 ( EN - AW - 6060 ) .
Spesor xhami, aksesor i rendesishem per mbeshtetjen e xhamit dhe izolimin nga alumini Glass thickness , the most important accessory for supporting the glass and aluminum
Barreta termike 22 mm te perbera nga teknopolimere Thermal Bar of 22 mm consisting of teknopolimere Kundra valvul per shkarkim uji Against valve for water discharge Guarnicion EPDM me Dhome kompresioni 120 mm2, per izolim termik te sigurte EPDM seal with compression Room 120 mm2 , for sure thermal insulation.
SISTEMI CE 70 000 Sistem me mekanizem perimetral per komfort maksimal
70 000 CE SYSTEM Perimetral mechanism system for maximum comfort.
Technical performance System technology: Hybrid window in double skin technology, with all it’s advantages: interior manual or automatised sash, exterior parallel outward opening sash Two sashes that can be operated individually, no restrictions in use Integrated sun shading device, protected against high wind speeds, dirt and weathering Only 215 mm system depth, despite integrated solar protection, motor assistance and control system Inner sash protected from burglary or weathering even when outer window is open.
9
05 FOLDING SYSTEM
10
06 LIFT AND SLIDE SYSTEM
Basic characteristics • Thermally broken two chamber system with a 38 mm sash width • Stainless steel guide rails • High thermal resistance Uf= 3,9 W/m2K) • Perimeter sealing with Hi-Fin membrane brushes • PVCu interlock profile for improved thermal performance • Glazing thikness 20.0 - 26.0 mm. Product Line Construcion Options: • Sliding bypass (with or without a fly screen) • Sliding pocket wall (glazing or glazing with shutter or fly - screen) • Sliding multi panel (glazing) Certifications: • The design, the production process, and the qualily control of all profiles produced are certified with ISO 9001. • The process of electrostatic powder coating is certified by QUALICOAT and RAL (GSB)
11
P O R T F O L I O A NEX A O R G E S T T A F A
tafa.orgest@gmail.com mobile: +355 69 44 34 162 mobile: +39 32 71 82 12 01