emergency lighting
A1
KAT39EN
RZB
Rudolf Zimmermann, Bamberg GmbH
Rheinstrasse 16 D-96052 Bamberg Germany Telephone +49 951/79 09-374 Fax +49 951/79 09-212 www.rzb.eu export@rzb-leuchten.de
emergency lighting
www.rzb-lighting.com
CUSTOMERCONTACT RZB Rudolf Zimmermann, Bamberg GmbH Rheinstrasse 16, D-96052 Bamberg, Germany P.O. Box 29 40, D-96020 Bamberg, Germany Telephone Fax
+49 951/79 09-374 +49 951/79 09-212
export@rzb-leuchten.de
www.rzb-lighting.com
289
Contents Self-contained emergency lighting Self-contained monitoring systems Self-contained emergency luminaires Self-contained emergency conversion kits
8 - 23 24 - 111 112 - 121
Central and group battery systems Central battery systems (CPS)
122 - 140
Group battery systems (LPS)
141 - 157
Luminaires for central emergency power supply
158 - 239
Standards and regulations
240 - 267
Planning
268 - 269
Appendix
270 - 288
Service
272 - 273
EVG symbol
274
LED symbol
275
Catalogue number codes
276
Motifs and lettering for emergency luminaires
277
Motifs and lettering for luminaire signs
278 - 279
Lamps
280
Terms and conditions of sale and delivery
281
Catalogue number index
282 - 286
Alphabetical index
287 - 288
Technical support
289
After sales service
289
Contact for emergency lighting
289
1
SINGLE BATTERY New products
Self-contained monitoring systems 14
10
Self-contained emergency luminaires
18
LED
LED
22
LED
8h 28 - 29
26
LED
28, 30 - 31
LED
LED
54, 58 - 59
LED
36
38
LED
44, 47
LED
50
52
54, 55 LED
8h
8h 54, 58 - 59
LED
60
62
64
66
68
76 - 79
80 - 83
84
86
88
96
98
100
102
104
LED
70
72
74
90
92
94 LED
106
108
110
110
114
116 - 117
116 - 117
118
Self-contained emergency conversion kits
2
34
LED
8h
8h 54, 56 - 57
44, 46
44, 45
40 - 43
32
LED
LED
40 - 43
LED
8h
8h 28, 30 - 31
LED
CENTRAL BATTERY New products
Central battery systems (CPS) 128
132
138
Group battery systems (LPS) 142
LED
160
LED
162 - 163
LED
172 - 174
188, 192
LED
176, 178
176, 177
LED
162, 165
162, 164
LED
LED
Luminaires for central emergency power supply
LED
168
166
170
LED
176, 179
144
172 - 174 LED
182 - 185
LED
186
LED
188, 189 LED
LED
188, 190 LED
LED
188, 192
194
196
198
200
202
204
208 - 210
212 - 214
216
218
220
222
224
LED
206
LED
226
228
230
230
232
234
236
238
3
About us We have been making luminaires of exceptional
solutions. The use of select materials and our
quality for more than seven decades. At RZB,
ISO 9001:2000 quality assurance system are
our daily activities center around the nowadays
your guarantee of the outstanding quality and
often mentioned subjects of innovation, quality,
exceptionally long service life of our luminaires.
design, energy efficiency, environmental friend-
This applies in particular to the plastics, die-
liness and customer service.
cast components, luminaire glasses, and sur-
Our luminaires are manufactured using the most
face coatings used in our products.
advanced production technologies available
Many items in our portfolio are on hand at all
today. These products combine outstanding
times, thanks to our highly efficient logistics
innovation with the latest lighting technologies;
workflows and the fact that we keep a great
and the fact that we operate our own R&D
number of components and finished products
lab guarantees that all of our products comply
always in stock.
strictly with all applicable legal regulations. The designs of our luminaires combine optimal
We also provide presales advice, lighting system planning services, demos and workshops.
technical characteristics and exemplary functionality, thus enabling us to offer our customers the best possible luminaires and lighting
A view of our plant and its solar panels. Solar panel surface: 30,000 square meters Number of modules: 5,000 Output: more than 1.1 megawatts Greenhouse gas savings: 930,000 kilograms per year
4
Environmental stewardship Improved light source energy efficiency, lamps miniaturization, and the dizzying pace of advances in LED technology are the challenges currently facing the luminaire industry today, particularly in view of the fact that lighting accounts for 20 percent of worldwide energy consumption. The manufacture of incandescent light bulbs has
Energy efficiency without dimming the lights Another environmental aspect that plays a key role in designing and developing our luminaires is the use of extremely high quality materials, which are selected with durability, environmentally friendly manufacturing, and recyclability firmly in mind. This is our way of making a lasting contribution to environmental stewardship.
been phased out by law in the EU, thus making it more urgent than ever for the European lighting industry to develop luminaires that use new types of more energy efficient lamps.
5
Quality Our quality assurance system is DIN EN ISO 9001: 2000 compliant.
Photometry lab
Heat measurement lab
EMC lab
Memberships in industry organizations
6
Protection type testing
RZB emergency lighting: the smart choice Superior quality luminaires and luminaire designs We use the most advanced manufacturing technologies available and adhere to an extremely high development standard. We have more than three decades of experience in the use of high tech materials and the development of systems that allow for continuous improvement in the efficiency of emergency lighting.
All your luminaire needs from a single vendor
Installation
We offer a complete range of emergency and
When developing our luminaires, we always keep
general lighting products. This means that we
in mind the aspect of installation-friendliness,
can offer you integrated solutions for both
thus guaranteeing rapid and simple handling
types of applications – which in turn saves you
in building construction settings, thanks to the
the trouble of dealing with other vendors.
use of elements such as plug-in connectors and modular technologies.
Reliability Our luminaires integrate extremely reliable elec-
Customer service
tronics and are highly durable thanks to the
We offer comprehensive planning services for
use of exceptionally high quality electronic
customer specific emergency lighting systems,
components and high tech LED lamps – not to
and also provide support for the commission-
mention our extensive testing program, whose
ing phase. Plus you can count on outstanding
scope far exceeds the statutory minimum.
after-sales service from our team of experienced technicians and engineers.
Lighting technology The luminaires that we develop in our state of
Sustainability
the art lab meet all applicable industry stand-
Environmental sustainability is a top priority
ards. In emergency situations, our emergency
for us in terms of not only the manufacturing
luminaires enable building occupants to exit
process, but also – and especially – the finished
the building safely. And what’s more, the use
product. All of our luminaires contain 100 percent
of high tech LEDs allows for greatly reduced
recyclable materials that are notable for their
energy consumption.
exceptional durability and quality.
7
Monitoring system
DALI
MultiDigit®
MWEBplus
PZ 50
modular
modular
single module
single module
Colour display
•
–
–
–
Number of circuits, basic unit
2
1
1
1
Number of luminaires per circuit
64
125
125
50
max. 128
max. 125
max. 125
max. 50
•
•
max. 64 modules
max. 125 modules
–
–
Max. number of luminaires
4,096
15,625
125
50
Error visualisation
Display
LED
LED
LED
accessories (optional)
•
•
•
•
–
–
–
–
•
•
–
–
free
free
free
ring
IY-ST(Y) 2 x 2 x 0.8 or NYM
IY-ST(Y) 4 x 2 x 0.8
IY-ST(Y) 2 x 2 x 0.8
IY-ST(Y) 2 x 2 x 0.8
small to large buildings
large to very large buildings
small to medium sized buildings
small buildings
Type of installation
Recessed wall installation, Surface wall installation
top hat rail
top hat rail
top hat rail
Accessories
Controller without display
Signal amplifier MWEB
–
–
System structure
Number of luminaires per basic unit
Expandable
Potential-free contacts for error messages E-mail communication
Network connection
Modualr structure
Bus line topography
Bus line
Installation environment
8
•
•
(optional)
(optional)
• (optional)
Self-contained monitoring systems DALI
monitoring system
10 - 13
MultiDigit速
monitoring system
14 - 17
MWEBplus
monitoring system
18 - 21
PZ 50
monitoring system
22 - 23
9
emergency Lighting | Self-contained monitoring systems
Monitoring systems with DALI interface System benefits - DALI monitoring units with touchscreen and logical menu guidance - 2 circuits, with 64 luminaires each - All luminaires with self-test function - Lighting in complex building structures can easily be realized via network connection - Visualisation of connected system(s) via TCP/IP (optional) - Automatic generation of detailed log book - Execution of all mandatory controls at minimum costs - Programmable also via USB - Formation of groups - Preinstalled operating software - System setup with software via USB - Bidirectional communication between luminaire and touchscreen with status and error messages - Easy to install, setup and maintain - Bus structure: star-shaped, linear and tree-shaped - Control line: DC-isolated and reverse voltage protected - No specific bus line required - Password protection - Emergency lighting function disabled outside of normal operating hours - No need to respect bus line polarity
Please note: All modules and luminaires for DALI must have order suffix (Y) .07
10
Easy to operate via touchscreen
emergency Lighting | Self-contained monitoring systems
DALI interface System description This system is based on the DALI Standard (IEC 62034 and IEC 62386) and allows for central monitoring of up to 128 self-contained emergency luminaires. It is operated and monitored via touchscreen (DALI control unit) with logical menu guidance for easy use. The DALI control unit is housed in a high-quality metal casing for either surface wall installation or recessed wall installation. By interconnecting more control units, the monitoring of emergency lighting systems can be easily realized even in complex building structures. For this purpose the single DALI control units can be interconnected via an existing local network (TCP/IP), and the entire system can be operated and monitored from one central PC. Ethernet
As an option it is also possible to control the system via internet. The DALI control unit communicates continuously with the connected selfcontained emergency luminaires and is thus able to immediately display any error. The logical menu guidance provides the operator within a few steps detailed information concerning type and location of the respective error as well as further indications for error elimination, if applicable.
BUS port Mains port
Automatic self-test function of the luminaires as well as generation of a detailed test log contribute notably to a reduction of time and costs for mandatory emergency lighting systems tests. Luminaires / Modules: order suffix .07
Surface wall installation
Power supply:
Recessed wall installation
230 V / 50-60 Hz
Power supply (bus line): max. 250 mA, 22.5 V
L
HE H
Max. bus length:
300 m (between control unit and last luminaire)
Transfer rate:
1,200 Bit/s at a voltage level of 16 V
B BA B
L
H
LA
Monitoring system DALI 985405 Surface L 148,5, B 92, H 60 985406 Recessed L 148,5, B 92, H 8, HE 52, LA 135, BA 80
Rear view of DALI unit
CAT. 5 Ethernet (network optional)
L PE N Disable function (optional) DALI circuit 2 DALI circuit 1
L N L
Tender texts available upon request | Specifications subject to alteration
11
emergency Lighting | Self-contained monitoring systems
Monitoring via DALI interface
General mains power supply
L N
General mains power supply DALI BUS circuit 1 L max. 64 luminaires max. 300 m
N
General mains power supply
L DALI BUS circuit 2
N
DALI Controller
12
Tender texts available upon request | Specifications subject to alteration
emergency Lighting | Self-contained monitoring systems
Monitoring via DALI interface
Ethernet Switch
Mains 230 V
DALI BUS2 x 1.5 mm2
L` (depending N L PE
on version)
L` (depending N L PE
on version)
DALI BUS 2 x 1.5 mm2
6 5 4 3 2 1
L` (depending N L PE
on version)
6 5 4 3 2 1
L` (depending N L PE
on version)
6 5 4 3 2 1
L` (depending N L PE
on version)
6 5 4 3 2 1
L` (depending N L PE
on version)
6 5 4 3 2 1
L` (depending N L PE
on version)
DALI module 1
DALI BUS-curcuit 1 Max. 64 luminaires Max. length: 300 m
DALI module 2
L` (depending N L PE
on version)
DALI module 3
L` (depending N L PE
on version)
L` (depending N L PE
on version)
DALI module 4
DALI module 64
Tender texts available upon request | Specifications subject to alteration
DALI module 1
DALI module 2
DALI BUS-curcuit 2 Max. 64 luminaires Max. length: 300 m
DALI module 3
DALI module 4
DALI module 64
6 5 4 3 2 1
6 5 4 3 2 1
6 5 4 3 2 1
6 5 4 3 2 1
6 5 4 3 2 1
13
emergency Lighting | Self-contained monitoring systems
Monitoring systems for large buildings MultiDigit® System benefits Continuous central local monitoring of all emergency luminaires using a normal PC, or intranet/internetbased monitoring using MWEB module (PC for system control can thus be eliminated).
- Interference-free communication provided by signal amplifier; communication line length: max. 2 x 1,000 m - Simple installation of communication line: T-shaped, star-shaped, linear or even mixed structure. No need to respect polarity.
- Automatic system configuration - Plain-text reports of all malfunctions, with indication of failure location
- Emergency lighting function disabled outside of normal operating hours
- Coordination of self-test activation of all self-contained emergency luminaires
- Remote control of MultiDigit® systems via modem or MWEB
- Error message logs (PC and/or printer) - Detailed information and control options for each single emergency luminaire
- Ongoing records of all system malfunctions - Automatic generation of detailed system test log
- Input port for evacuation function (fire brigade)
- Execution of all mandatory emergency lighting system controls at minimum costs
- Each signal amplifier is fitted with a tap for forwarding collective/group errors to superior systems
- Password protection for system data changes
- Max. 15, 625 luminaires
max. 30 m max. 1,000 m at 0.8 mm2
Type of bus line: e.g. J-Y(St)Y 2x2x0.8
General circuit diagram for the MultiDigit® monitoring system
Min. No. of lumi- Max. line length cross-section naires of bus line per line
Signal converter
Signal amplifier no. 1
No. 1
No. 2
No. 3
No. 4
No. 1
No. 2
No. 3
No. 4 2
max. 1,000 m at 0.8 mm
Type of bus line: e.g. J-Y(St)Y 2 x 2 x 0.8 * The minimum cross-section of the bus line depends on the actual length of the bus line and the number of connected luminaires. Please consult the WINLink manual for detailed information on cable cross-sections.
14
40
1,000 m
0.5 mm2
J-Y(St) Y 2 x 2 x 0.8 mm (one core)
80
1,000 m
1.0 mm2
J-Y(St) Y 2 x 2 x 0.8 mm (two cores)
125
1,000 m
1.5 mm2
J-Y(St) Y 4 x 2 x 0.8 mm (three cores)
max. 125
Emergency luminaires with order suffix .04 Signal amplifier max. 125
Cable type, e.g.:
max. 125 up to 125 luminaires
emergency Lighting | Self-contained monitoring systems
MultiDigitÂŽ System description The MultiDigitÂŽ system allows for continuous central control of selfcontained emergency luminaires, which report their momentary states to a PC, which evaluates and controls the entire system. An immediate and clear overview of the entire system can thus be provided and used for determining the operational readiness of the emergency lighting system.
Ease of use is ensured by the user-friendly software WINLink, which runs under any current Windows operating system.
The system is very easy to set up. 125 signal amplifiers (grouped and with 125 self-contained emergency luminaires each) can be installed according to the general circuit diagram indicated on page 14. The signal amplifiers ensure interference-free communication over transmission lengths of up to 2,000 meters throughout the entire system. B
L
The communication line does not need to comply with any particular requirements; its structure can be T-shaped, star-shaped, linear or even mixed. Bus line polarity needs not to be considered. One fully-installed H system can monitor 15,625 luminaires.
Planning and installation The address of the emergency luminairs’ signal amplifiers is stored in a microcontroller and therefore needs to be indicated when ordering the system. It can be reprogrammed during the system setup. System setup and training of the operating personnel by an RZB technician is available upon request and charge. For information concerning technical issues and planning assistance, please contact your sales representative.
Tender texts available upon request | Specifications subject to alteration
15
emergency Lighting | Self-contained monitoring systems
MultiDigit® Starter set Type of protection: IP 20 Protection Class: I for connecting a maximum of 125 RZB luminaires with feedback function (.04), consisting of signal amplifier, signal converter, software and 5 m connecting cable to serial interface of PC (SUB-D9). Type of installation: DIN profile track Starter set 671315.000
L 155, B 75, H 120
Signal amplifier For connecting a further 125 RZB luminaires with incorporated feedback (.04) Signal amplifier 671148.000
L 155, B 75, H 120
B
MWEB monitoring module
H
L
for connection to signal amplifier via enclosed interface cable. The MWEB monitoring module forms the interface between the bus system of the MultiDigit® system and an on-site Ethernet network. MWEB performs the entire control and error management of the emergency lighting system. The system does not require its own PC. The MWEB module can be accessed via web navigator from any PC in the network that is connected to intranet/internet, without the need for any special software. For this purpose, the data stored in MWEB are transmitted to the navigator via TCP/IP protocol. Any malfunction within the system will be immediately displayed in the navigator window; the incorporated e-mail function allows detailed information on the malfunction to be sent to the system administrator. The system can also be accessed via internet if the network is configured accordingly.
B
L
H
MWEB monitoring module 671611.000 L 158, B 90, H 58
16
Tender texts available upon request | Specifications subject to alteration
emergency Lighting | Self-contained monitoring systems
Monitoring via MWEB Please note: RS 232 direct line max. 10 m
(5)
Ethernet Switch
(6)
MultiDigit® signal amplifier-M2
All modules and luminaires for MultiDigit® must have order suffix (Y) .04
(7)
W eb br
blin k. = Kom munikation
Überwachungsmodul für MultiDigit Notbeleuchtungssysteme
MWEB
Sig na lv erstä rker M-B US 28V D C
N
L
Meter BUS 28 V DC
.
.
zu Signalwandler
Art.Nr.: 671611.000
Art.Nr.: 671149.000
L
.
IP
ows er
RS232 nur für Wartung System
LAN Ethernet
Sig na lv erstä rker M-B US 28V D C
N
RS 232 / max. 10 m Max. 125 signal amplifier / Max. line length: 1,000 m
(4) (2)
(4)
MultiDigit® signal amplifier-M2 Art.Nr.: 671148.000
N
Art.Nr.: 671148.000
Notlichtbausteine M-BUS 28 V DC
M-BUS 28V DC
87 654 321
Meter BUS 28 V DC
L
Notlichtbausteine M-BUS 28 V DC
N
Spez.
Meter BUS 28 V DC
MultiDigit® module 1
MultiDigit®
module 2
6 5 4 3 2 1
N L PE
MultiDigit®
N L PE
MultiDigit® module 3
6 5 4 3 2 1
N L PE
N L PE
MultiDigit®
6 5 4 3 2 1
module 2
MultiDigit® module 3
6 5 4 3 2 1
N L PE
MultiDigit® module 1
6 5 4 3 2 1
6 5 4 3 2 1
N L PE
MultiDigit®
6 5 4 3 2 1
N L PE
module 125
6 5 4 3 2 1
Tender texts available upon request | Specifications subject to alteration
module 2
6 5 4 3 2 1
(1) Communication line (2) Main line (3) Multidigit emergency luminaires
MultiDigit®
87 654 321
Meter BUS 28 V DC
MultiDigit® module 1
N L PE
Notlichtbausteine M-BUS 28 V DC
N
Allg.
M-BUS 28V DC
(1) N L PE
module 4
L
Spez. Hauptleitung
SN 104
87 654 321
6 5 4 3 2 1
N L PE
Art.Nr.: 671148.000
M-BUS 28V DC
(1) N L PE
MultiDigit® signal amplifier-M2
Allg.
Hauptleitung
SN 27
(1)
Max. 125 luminaires / Max. line length: 1,000 m
MultiDigit® signal amplifier-M2
Allg.
Hauptleitung
SN 07 L
Spez.
(4)
MultiDigit®
module 125
6 5 4 3 2 1
(4) Signal amplifier (K box) (5) Signal converter (K vert) (6) MWEB (optional) (7) PC with web browser
17
emergency Lighting | Self-contained monitoring systems
Monitoring systems MWEBplus System benefits Continuous central local monitoring of all emergency luminaires (PC for system control is not required). - Automatic system configuration - Plain-text reports of all malfunctions, with indication of failure location - Coordination of self-test activation of all self- contained emergency luminaires - Error message logs (PC and/or printer) - Detailed information and control options for each single emergency luminaire
- Interference-free communication provided by signal amplifier; communication line length: max. 1,000 m - Simple installation of communication line: T-shaped, star-shaped, linear or even mixed structure. No need to respect polarity. - Emergency lighting function disabled outside of normal operating hours - Ongoing records of all system malfunctions - Automatic generation of detailed system test log - Execution of all mandatory emergency lighting system controls at minimum costs
- Tap for forwarding collective/group errors - Max. 125 luminaires - Failures will be communicated automatically via e-mail to individually assignable addresses
- Password protection for system data changes - No need to respect bus line polarity
General circuit diagram for the MWEBplus monitoring system MWEBplus No. 1
No. 2
No. 3
No. 4
Min. No. of lumi- Max. line length cross-section naires of bus line per line
max. 125
2
max. 1,000 m at 0.8 mm
Bus line type: e. g. J-Y(St)Y 2 x 2 x 0.8
Emergency luminaires with order suffix .04 * The minimum cross-section of the bus line depends on the actual length of the bus line and the number of connected luminaires.
18
Cable type, e.g.:
40
1,000 m
0.5 mm2
J-Y(St) Y 2 x 2 x 0.8 mm (one core)
80
1,000 m
1.0 mm2
J-Y(St) Y 2 x 2 x 0.8 mm (two cores)
125
1,000 m
1.5 mm2
J-Y(St) Y 4 x 2 x 0.8 mm (three cores)
emergency Lighting | Self-contained monitoring systems
MWEBplus System description The MWEBplus system allows for continuous central control of selfcontained emergency luminaires, which report their momentary states to a PC, which evaluates and controls the entire system. An immediate and clear overview of the entire system can thus be provided and be used for determining the operational readiness of the emergency lighting system. The system is very easy to set up. 125 self-contained emergency luminaires can be installed according to the general circuit diagram indicated on page 18. The communication line does not need to comply with any particular requirements; its structure can be T-shaped, star-shaped, linear or even mixed.
B
L
H
MWEBplus constitutes the interface between the system’s OS and an onsite Ethernet network. Since MWEBplus performs the entire control and error management of the emergency lighting system, a separate PC for the monitoring system is not required. The MWEBplus module can be accessed via web navigator from any PC in the network that is connected to intranet/internet, without the need for any special software. For this purpose, the data stored in MWEBplus are transmitted to the navigator via TCP/IP protocol. Any malfunction within the system will be immediately displayed; the incorporated e-mail function allows detailed information on the malfunction to be sent to the system administrator. The system can also be accessed via internet if the network is configured accordingly. Monitoring module MWEBplus 671823.000 L 160, B 110, H 63
Tender texts available upon request | Specifications subject to alteration
19
emergency Lighting | Self-contained monitoring systems
Monitoring via MWEBplus
General mains power supply
L N
General mains power supply
max. 125 luminaires max. 1,000 m
L N
General mains power supply
L
Bus N
MWEBplus
Please note: All modules and luminaires for MWEBplus must have order suffix (Y) .04
20
Tender texts available upon request | Specifications subject to alteration
emergency Lighting | Self-contained monitoring systems
Monitoring via MWEBplus
Ethernet Switch
hEHUZDFKXQJVPRGXO IÂ U 08/7,',*,7 1RWEHOHXFKWXQJVV\VWHPH 5(6(7
0 :(%SOXV
Mains 230 V
,3
$UW 1U 9 +]
7 $
7[
/$1 (WKHUQHW
7 P$ ]X 1RWOLFKWEDXVWHLQHQ 9
56 QXU IÂ U :DUWXQJ 6\VWHP 7 P$ 9
5[
Meter-BUS 30 V DC 2 x 1.5 mm2
N L PE
N L PE
N L PE
MultiDigitÂŽ module 1
MultiDigitÂŽ module 2
MultiDigitÂŽ module 3
6 5 4 3 2 1
6 5 4 3 2 1
6 5 4 3 2 1
Max. 125 luminaires Max. length: 1,000 m
N L PE
N L PE
Tender texts available upon request | Specifications subject to alteration
MultiDigitÂŽ module 4
MultiDigitÂŽ module 125
6 5 4 3 2 1
6 5 4 3 2 1
21
emergency Lighting | Self-contained monitoring systems
Monitoring systems PZ 50 for 50 self-contained luminaires System benefits - Central monitoring of the entire system - Simple and clear structure - Automatic function tests - Simple test log generation - Easy to install - Execution of all mandatory tests at minimum costs - Collective error display on the monitoring unit - Blinking codes on each luminaire indicate the type of error
PZ 50 monitoring system continuous control of max. 50 emergency luminaires
Please note: All modules and luminaires for PZ 50 must have order suffix (Y) .03
22
Up to 50 emergency lights! Max. length of bus line: 400 m (total length of loop wiring system!) Type of bus line: e.g. J-Y(St)Y 2x2x0.8
200 V / 50 Hz
200 V ac BUS Loop wiring system
Self-test module or luminaire / ballast with order suffix .03
emergency Lighting | Self-contained monitoring systems
PZ 50 Description The feedback unit PZ 50 allows for central monitoring of self-test emergency luminaires (.03). The monitoring unit displays any error of any connected emergency luminaire as well as any BUS line disconnection. Moreover, it displays whether the power supply is on or off. It can, however, not be seen which of the luminaires is involved in the failure. Up to 50 luminaires can be connected to one control unit via a loop wiring system.
B
Suitable cable type for this system is for example cable J-Y(ST)-Y 2 x 2 x 0.8. Attention: bus line voltage may reach up to 200 V. The maximum line length amounts to 400 meters, which means that the farest distance between any luminaire and the control unit may be max. 200 meters. The BUS line must not be conducted thorough the same cable through which the power supply line is conducted. Functioning
L
Automatic luminaire self-test H The emergency luminaires are fitted with additional automatic self-test electronics for testing the luminaire itself, the battery and the lamp of the luminaire, following an optimized testing programme defined for these luminaires. The testing result will be transformed into a visual and audible alarm. Benefits of autonomous self-test electronics: - High reliability - Low maintenance - Ease of use - Time saving testing and controlling process Any malfunction within the system will be displayed on the unit as a collective malfunction, which can be forwarded to any superior system via a potential-free contact (230 V AC/5 A or 24 V/5 A). Monitoring system for RZB self-contained emergency luminaires with order suffix .03 Type of protection:
IP 20
Protection class:
I
Power supply:
230 V / 50/60 Hz
Power supply (bus line):
200 V
Alarm delay:
10 seconds
Dimensions:
L 158, H 90, T 58
Type of installation:
DIN profile track
Max. bus line length:
400 m
Max. no. of luminaires that can be monitored: 50 luminaires Potential-free contact:
230 V AC / 5 A 24 V DC / 5 A
Monitoring system PZ 50 671466.009 L 158, H 90, T 58
Tender texts available upon request | Specifications subject to alteration
23
24
LED
LED
LED
8h
8h 26
LED
LED
8h
28 - 29
28, 30 - 31
28, 30 - 31
32
36
38
40 - 43
40 - 43
50
52
LED
34 LED
44, 45
LED
LED
44, 47
44, 46
LED
LED
LED
8h
8h 54, 56 - 57
54, 55
LED
54, 58 - 59
8h 54, 58 - 59
60
LED
LED
8h 62
64 LED
66
68
70
LED
72
74
76 - 79
80 - 83
84
86
88
90
92
94
96
98
100
102 LED
106
108
110
110
104
Self-contained emergency luminaires Tenuo LED Halyxx® GSUN® S Ilustris Display Flat Sign Mini/Midi Design Rechteck 250 / 360 / 485 Multivariabel Signcube GSUN® 2 GSUN® 2 LED GSUN® 3 GSUN® 3 LED GSUN® 4 GSUN® 4 LED LCS1 LCS3 Varioplast I Space Universum Turia Edo Lucio Centryxx Energo TC 175 Energo TC 210 Andho TC Andho TC IP 65 Arelo® Mondana Flat Polymero® Flat Polymero® PC with collar Flat Basic Flat Basic with collar Flat Polymero® Rechteck Basic Kreis Rondo Rounded® Maxi Alu‑Rund Weatherproof battens Hand‑held LED safety spotlight Safety stand spotlight
26 28 32 34 36 38 40 44 50 52 55 55 56 57 58 59 60 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 110
25
emergency Lighting | self-contained emergency luminaires Tenuo Type of protection: IP 40
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- The flattest existing emergency luminaire that incorporates the very latest energy saving LED technology - Ultraflat - (panel 5 mm) frame 8 mm
1003
1004
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
1113
1115
1114
1116
- Top quality LED technology - Specially calculated thermal management - The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours
1005
- Exceptionally high luminance of over 900 cd/m2 - Wide range of applications thanks to various types of installation
Wall extension
26
Wall (semi-recessed)
Ceiling (surface)
Ceiling (recessed)
Pendant tube
Suspension cable/chain
emergency Lighting | self-contained emergency luminaires Series: Tenuo Type of protection: IP 40 Protection class: I Viewing distance: 30 m For escape route identification Housing: aluminium, silver. Display panel with patented MicroLens technology. LED included. Please indicate symbol number when placing your order! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
30 m
Available colour (X): 4 = aluminium, anodised
Wall extension
Wall (surface)
Wall (semi-recessed)
Ceiling (surface)
Ceiling (recessed)
Suspension cable/chain
Pendant tube
LP L
L
B
LA
B
H
L
Installation scheme available on request
Article number
Type of installation
671944.00X.Y
Installation scheme available on request
H
H
B
BA
LA
Installation scheme available on request
L
B
H
L
B
B
L
Installation scheme available on request
LP
HE
HA H
H
H
L
TE B
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Viewing distance
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Wall (surface)
30 m
-
1 x LED 2,5 W
-
-
•
3h
L 350, B 33, H 200
671945.00X.Y
Wall extension
30 m
-
1 x LED 5 W
-
-
•
3h
L 400, B 60, H 200
671943.00X.Y
Wall (semirecessed)
30 m
-
1 x LED 2,5 W
-
-
•
3h
L 350, B 11, H 200, LA 173, BA 173, TE 70
671946.00X.Y
Ceiling (surface)
30 m
-
1 x LED 5 W
-
-
•
3h
L 350, B 50, H 240
671947.00X.Y
Ceiling (recessed)
30 m
-
1 x LED 5 W
-
-
•
3h
L 420, B 40, H 252, LA 400, BA 40, HE 90
671948.00X.Y
Pendant tube
30 m
-
1 x LED 5 W
-
-
•
3h
L 350, B 50, H 200, LP 500
671949.00X.Y
Suspension cable/chain
30 m
-
1 x LED 5 W
-
-
•
3h
L 350, B 50, H 200, LP 500
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Rated operat‑ Dimensions ing time
27
emergency Lighting | self-contained emergency luminaires LED HalyxxÂŽ Type of protection: IP 40
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- High quality aluminium housing - High quality and elegant design - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - Specially calculated thermal management
1003
1004
1113
1115
1114
1116
- The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours - Luminance exceeds 500 cd/m2
1005
- Wide range of applications thanks to various types of installation - Moulded housing for concrete available - Easy to install
8h
for accomodation facilities, nursing homes and multi-storey buildings (only in Germany)
Wall (surface)
28
Ceiling (surface)
Ceiling (recessed)
Wall (recessed)
emergency Lighting | self-contained emergency luminaires Series: LED Halyxx® Type of protection: IP 40 Protection class: I Viewing distance: 14 m Ceiling thickness: 5-35 mm Wall thickness: 1-30 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides. LED included. Please specify legend number when ordering! 14 m
Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colours (X): 2 = white (only Wall (recessed)) 4 = aluminium, anodised (all variants)
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
Wall (recessed) (cavity wall)
L
Ø4,5 23
L
B
3 15
180
40
Type of installation
671501.00X.Y
B
55
Ø5
Viewing distance
Luminous flux factor
Wall (surface)
14 m
-
671502.00X.Y
Ceiling (surface)
14 m
671518.00X.Y
Ceiling (recessed)
671546.12X.Y 671546.00X.Y
HE
HA H
B
HA H
LA
LA
1-30
220 210
42
150
220 200
150
132
130
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
4 x LED 1 W
•
•
•
3h
L 233, B 40, H 180
-
4 x LED 1 W
•
•
•
3h
L 233, B 40, H 180
14 m
-
4 x LED 1 W
•
•
•
3h
L 270, B 55, H 100 LA 255 x BA 42, HE 90
Wall (recessed) (cavity wall)
14 m
-
1 x LED 4 W
•
•
–
3h
L 220, B 2, H 150 LA 210 x BA 132, HE 90
Wall (recessed) (solid wall)
14 m
-
1 x LED 4 W
•
•
–
3h
L 220, B 2, H 150 LA 200 x BA 130, HE 80
Wall extension Viewing distance: 14 m 981581.004 L 258, B 38, H 104
Lamp/Wattage
L
BA
270 255
16
150 233
Article number
LA L
50
12,5
151 233
H
B
45
15
5-35
H
H
HE B
L
HE
Wall (recessed) (solid wall)
Rated operat‑ Dimensions ing time
for art. 671502.004.Y
Accessories | Pendant set for ceiling luminaires Pendant length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site. Pendant sets Viewing distance: 14 m 981639.010 for art. 671502.004 981639.030 for art. 671502.004.03 981639.040 for art. 671502.004.04/.07
Mounting set for suspension cable/chain Viewing distance: 14 m 981701.004 L 213, B 33, H 77
for art. 671502.004.Y
Moulded housing Viewing distance: 14 m 981685.000 L 542, B 142, H 143
for art. 671518.004.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
29
emergency Lighting | self-contained emergency luminaires Series: LED Halyxx® Type of protection: IP 40 Protection class: I Viewing distance: 19 m Ceiling thickness: 5-35 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides. LED included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS).
19 m
Ballast mains/emergency: EB Available colour (X): 4 = aluminium, anodised
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
HE
L
B
Ø4,5 23
H
15
L
5-35
H
H LA L
B
BA B
45 3
50
15
12,5
220
320 305
16
40
150 233
151 235
Article number
Type of installation
671746.00X.Y
Wall (surface)
Viewing distance
Luminous flux factor
19 m
-
55
Ø5
Lamp/Wattage
42
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
4 x LED 1 W
•
•
•
Rated operat‑ Dimensions ing time 3h
L 235, B 40, H 220
671895.00X.Y
Wall (surface)
19 m
-
4 x LED 1 W
•
•
-
8h
L 235, B 40, H 220
671742.00X.Y
Ceiling (surface)
19 m
-
4 x LED 1 W
•
•
•
3h
L 235, B 40, H 220
671896.00X.Y
Ceiling (surface)
19 m
-
4 x LED 1 W
•
•
-
8h
L 235, B 40, H 220
671750.00X.Y
Ceiling (recessed)
19 m
-
4 x LED 1 W
•
•
•
3h
L 320, B 55, H 140 LA 305 x BA 42, HE 90
671897.00X.Y
Ceiling (recessed)
19 m
-
4 x LED 1 W
•
•
-
8h
L 320, B 55, H 140 LA 305 x BA 42, HE 90
Wall extension Viewing distance: 19 m 981581.004 L 258, B 38, H 104
for art. 671742.004.Y
Accessories | Pendant set for ceiling luminaires Pendant length 500 mm (other lengths upon request), white plastic canopy, chrome pendant tube, length: 480 mm, can be shortened on site. Pendant sets Viewing distance: 19 m 981639.010 for art. 671742.004 981639.030 for art. 671742.004.03 981639.040 for art. 671742.004.04/.07
Mounting set for suspension cable/chain Viewing distance: 19 m 981701.004 L 213, B 33, H 77
for art. 671742.004.Y
Moulded housing Viewing distance: 19 m 981686.000 L 542, B 142, H 143
for art. 671750.004.Y
30
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
emergency Lighting | self-contained emergency luminaires Series: LED Halyxx® Type of protection: IP 40 Protection class: I Viewing distance: 30 m Ceiling thickness: 5-35 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides. LED included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS).
30 m
Ballast mains/emergency: EB Available colour (X): 4 = aluminium, anodised
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
L
B
Ø4,5 23
H
25
L
5-35
HE H
H LA L
B
BA B
45 3
25
15
Ø5
424 410
27,5
40
270
270 340
10,5
55
42
250 340
Article number
Type of installation
Viewing distance
Luminous flux factor
671748.00X.Y
Wall (surface)
30 m
-
671912.00X.Y
Wall (surface)
30 m
671744.00X.Y
Ceiling (surface)
30 m
671913.00X.Y
Ceiling (surface)
671752.00X.Y 671914.00X.Y
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
4 x LED 1 W
•
•
•
3h
L 340, B 40, H 270
-
4 x LED 1 W
•
•
-
8h
L 340, B 40, H 270
-
4 x LED 1 W
•
•
•
3h
L 340, B 40, H 270
30 m
-
4 x LED 1 W
•
•
-
8h
L 340, B 40, H 270
Ceiling (recessed)
30 m
-
4 x LED 1 W
•
•
•
3h
L 424, B 55, H 190 LA 410 x BA 42, HE 90
Ceiling (recessed)
30 m
-
4 x LED 1 W
•
•
-
8h
L 424, B 55, H 190 LA 410 x BA 42, HE 90
Wall extension Viewing distance: 30 m 981640.000 L 363, B 38, H 104
Lamp/Wattage
Rated operat‑ Dimensions ing time
for art. 671744.004.Y
Accessories | Pendant set for ceiling luminaires Pendant length 500 mm (other lengths upon request), white plastic canopy, chrome pendant tube, length: 480 mm, can be shortened on site. Pendant sets Viewing distance: 30 m 981647.010 for art. 671744.004 981647.030 for art. 671744.004.03 981647.040 for art. 671744.004.04/.07 Mounting kit for chains/cable suspensions Viewing distance: 30 m 981702.004 L 318, B 33, H 57
for art. 671744.004.Y
Moulded housing Viewing distance: 30 m 981687.000 L 542, B 142, H 143
for art. 671752.004.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
31
emergency Lighting | self-contained emergency luminaires GSUN® S Type of protection: IP 20 - Housing made of top quality aluminium - Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology) - The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours - Standard automatic self-test - Set of 3 easily attachable pictograms - Easy to install - Suitable for mounting on either a ceiling or a wall by simply changing the end caps
Wall (surface)
Ceiling (surface) 90°
90°
32
emergency Lighting | self-contained emergency luminaires Series: GSUN® S Type of protection: IP 20 Protection class: I Viewing distance: 24 m For escape route identification Housing: extruded aluminium profile, with universal installation set for ceiling and wall surface mounting. 3 foils with escape route motif and 1 white foil included for attachment. Automatic self test in all standard versions. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). LED included. Ballast mains/emergency: EB
24 m
Available colour (X): 4 = silver coloured
Wall (surface)
Ceiling (surface)
15
15
H
H
L
240 200
175
L
B
B
200
22,5
45
5,5x10
Article number 671915.00X.Y
5,5x10
Type of installation Wall (surface), Ceiling (surface)
Viewing distance
Luminous flux factor
24 m
-
Wall extension 981779.004
L 260, B 45, H 110
Pendant tube 981777.014
Pendant lenght 500 mm
Lamp/Wattage 1 x LED 1 W
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
with automatic self-test function, without feedback
Rated operat‑ Dimensions ing time 3h
L 240, B 45, H 190
Suspension cable/chain 981780.000 Pendant lenght 1500 mm
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
33
emergency Lighting | self-contained emergency luminaires Ilustris Type of protection: IP 20 - Design matches modern architectural styles - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours - Large viewing distance - Standard automatic self-test - Wide range of applications thanks to various types of installation
Wall (surface)
34
Ceiling (surface)
emergency Lighting | self-contained emergency luminaires Series: Ilustris Type of protection: IP 20 Protection class: I Viewing distance: 30 m For escape route identification Housing: die-cast aluminium, powder-coated. 3 foils with escape route motif and 1 white foil included. Automatic self test in all standard versions. LED included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
30 m
Available colour (X): 31 = anthracite metallic
Wall (surface)
Ceiling (surface)
H
H
B
L
35
150
22
B
L
55
253
368 100 368
26
5,5x10
120 Ø5,5
Article number
Type of installation
Viewing distance
Luminous flux factor
671842.00X.Y 671846.00X.Y
Wall (surface)
30 m
-
1 x LED 3 W
Ceiling (surface)
30 m
-
1 x LED 3 W
Wall extension 981775.0031
L 300, B 150, H 35
Pendant tube 981777.0031
Pendant lenght 500 mm
Suspension cable/chain 981776.000 Pendant lenght 1500 mm
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
with automatic self-test function, without feedback
Rated operat‑ Dimensions ing time 3h
L 368, B 55, H 253
3h
L 368, B 27, H 263
–
–
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
35
emergency Lighting | self-contained emergency luminaires Display Type of protection: IP 40
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- Absolutely uniform illumination of the motifs - Wide range of applications thanks to various types of installation - Designed for large viewing distances - Standard fluorescent lamps can be used - Specifically calculated reflector inside the luminaire
1003
1004
1113
1115
1114
1116
1005
Wall (surface)
36
Ceiling (surface)
Ceiling (recessed)
emergency Lighting | self-contained emergency luminaires Series: Display Type of protection: IP 40 Protection class: I Viewing distance: 32 m For escape route identification Base: metal, powder-coated. Display panel: plastic, with motifs on one side/on both sides. Lamp included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
32 m
Available colours (X): 2 = white, 4 = silver metallic
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
LA 1-40
BA
H
HE
H H
L
B
B
L
B
L
248
60 51
125
5x8
332 276
16
236
400
18
96
84
68
57 5x8
380
332
Article number
Type of installation
Viewing distance
Luminous flux factor
671005.75X.Y
Wall (surface)
32 m
-
671001.75X.Y
Ceiling (surface)
32 m
671003.75X.Y
Ceiling (recessed)
32 m
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x T16 (T5) 8 W
•
•
-
3h
L 332, B 70, H 236
-
1 x T16 (T5) 8 W
•
•
-
3h
L 332, B 57, H 305
-
1 x T16 (T5) 8 W
•
•
-
3h
L 400, B 80, H 180 LA 380 x BA 68, HE 165
Accessories | Wall extension Steel bracket, white powder-coated Wall extension 981489.002 Accessories | Pendant set Suspension tube, square: 40 x 40 mm, powder-coated, suspension length 500 mm (other lengths available upon request) Pendant set 90-3757.002 90-3757.004
Pendant length 500 mm Pendant length 500 mm
white silver metallic
Moulded housing 98186.000
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
37
emergency Lighting | self-contained emergency luminaires Flat Sign Mini/Midi Type of protection: IP 43
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- Exclusive luminaire design - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
1003
1004
1113
1115
1114
1116
- Top quality LED technology - Uniform light distribution provided by special LED arrangement - 2 different housing dimensions for different viewing distances
1005
Wall (surface)
38
Pendant tube
emergency Lighting | self-contained emergency luminaires Series: Flat Sign Mini/Midi Type of protection: IP 43 Protection class: I Viewing distance: 21 m, 32 m For escape route identification Housing: sheet steel, powder-coated; display panel: plastic, opal, with motifs on one side/on both sides. LED included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
21 m/32 m
Available colour (X): 2 = white
Wall (surface) Mini
Wall (surface) Midi
Pendant tube
LP H
L
H
B
L
B
H B
L
60
27
9x5 8
Ø20
Ø10
9x5
125
178
Ø20
120 237
10
27
30
Ø3,5
237 348
Article number
Type of installation
Viewing distance
Type
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
671558.00X.Y
Wall (surface)
21 m
Mini
4 x LED 0,5 W
•
•
-
3h
L 237, B 84, H 125
671559.00X.Y
Wall (surface)
32 m
Midi
4 x LED 0,5 W
•
•
-
3h
L 348, B 84, H 178
671560.00X.Y
Pendant tube
21 m
Mini
4 x LED 1 W
•
•
-
3h
L 237, B 138, H 125, LP 480
671615.00X.Y
Pendant tube
32 m
Midi
6 x LED 1 W
•
•
-
3h
L 348, B 138, H 178, LP 480
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Rated operat‑ Dimensions ing time
39
emergency Lighting | self-contained emergency luminaires Design Type of protection: IP 40
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- Flat aluminium housing in elegant design - Installation-friendly design enables lamp replacement without tools - Designed for large viewing distances - Wide range of applications thanks to various types of installation - Luminaire also available for escape route illumination
1003
1004
1113
1115
1114
1116
1005
8h
for accomodation facilities, nursing homes and multi-storey buildings (only in Germany)
Ceiling (surface), Wall (surface)
40
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
emergency Lighting | self-contained emergency luminaires Series: Design Type of protection: IP 40 Protection class: I Viewing distance: 26 m For escape route identification Housing: aluminium, powder-coated. Display panels: plastic, opal, with motifs on one side/on both sides. Lamp included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
26 m
Available colour (X): 2 = white
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
LP H
H
H
190
H
L
B
B
L
B
L
L
B
18
294
5,5x10 190
75
90 190
15
340
27 210
Article number
Type of installation
671590.75X.Y
Wall (surface)
42
52,5
6
169,5
6
60
55
Ø6
52,5
5x12
340
82
82
55
Viewing distance
Luminous flux factor
26 m
-
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
•
•
-
1 x T16 (T5) 6 W
Rated operat‑ Dimensions ing time 3h
L 294, B 55, H 190
671594.75X.Y
Wall extension
26 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 314, B 55, H 190
671592.75X.Y
Ceiling (surface)
26 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 340, B 55, H 232
671596.75X.Y
Pendant tube
26 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 340, B 55, H 190, LP 524
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
41
emergency Lighting | self-contained emergency luminaires Series: Design Type of protection: IP 40 Protection class: I Viewing distance: 33 m For escape route identification Housing: aluminium, powder-coated. Display panels: plastic, opal, with motifs on one side/on both sides. Lamp included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
33 m
Available colour (X): 2 = white
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
LP H
H
H
228
H
L
B
B
L
B
L
L
28
370
47
55
228
90
117 228
416
42
Type of installation
671017.75X.Y
Wall (surface)
53
5x12
Viewing distance
Luminous flux factor
33 m
-
Lamp/Wattage 1 x T16 (T5) 8 W
416
6
60 Ø6
18
6x16
Article number
55 53
5x10
283
6
208
B
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
•
•
-
82 82
Rated operat‑ Dimensions ing time 3h
L 370, B 55, H 228
671588.75X.Y
Wall (surface)
33 m
-
1 x T16 (T5) 8 W
•
•
-
8h
L 370, B 55, H 228
671023.75X.Y
Wall extension
33 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 390, B 55, H 228
671219.75X.Y
Ceiling (surface)
33 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 416, B 55, H 270
671717.75X.Y
Ceiling (surface)
33 m
-
1 x T16 (T5) 8 W
•
•
-
8h
L 416, B 55, H 270
671311.75X.Y
Pendant tube
33 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 416, B 55, H 228, LP 500
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
42
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
emergency Lighting | self-contained emergency luminaires Series: Design Type of protection: IP 40 Protection class: I For escape route illumination Housing: aluminium, powder-coated. Refractor: transparent plastic, prismatic. Reflector: aluminium, highly polished anodised finish, wide beam. T16 fluorescent lamp included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: LLB/EB Available colour (X): 2 = white
Wall (surface), Ceiling (surface)
8W
Wall (surface), Ceiling (surface)
H L
35
44
44
Article number
Type of installation
6x16
615
Luminous flux factor
Lamp/Wattage
B
1605
64
117 228
317
44
58 W
H L
B
64
120 228
Viewing distance
Wall (surface), Ceiling (surface)
1305
695
52
6x16
36 W
H L
B
370
117 228
Wall (surface), Ceiling (surface)
H L
B
64
18 W
44
117 228
313
44
6x16
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
44
6x16
Rated operat‑ Dimensions ing time
671009.75X.Y
Ceiling (surface), Wall (surface)
-
41 %
1 x T16 (T5) 8 W
•
•
-
3h
L 370, B 228, H 55
671011.75X.Y
Ceiling (surface), Wall (surface)
-
20 %
1 x T26 (T8) 18 W
•
•
-
3h
L 695, B 228, H 55
671586.75X.Y
Ceiling (surface), Wall (surface)
-
40 %
1 x T26 (T8) 18 W
•
•
-
8h
L 695, B 228, H 55
671013.75X.Y
Ceiling (surface), Wall (surface)
-
13 %
1 x T26 (T8) 36 W
•
•
-
3h
L 1305, B 228, H 55
671447.75X.Y
Ceiling (surface), Wall (surface)
-
8%
1 x T26 (T8) 58 W
•
•
-
3h
L 1605, B 228, H 55
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Spacing table 671447.752
Spacing table 671013.752
Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Lamp luminous flux:
Lamp luminous flux:
Mains: 5200 lm, Emergency: 416 lm
Mains: 3350 lm, Emergency: 469 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
d
h
a
b
2.5
8.6
3.5 11.2
4.6
2.5
8.8
3.7 14.0
5.8
3.0
9.2
3.7 12.0
4.8
3.0
9.4
3.9 12.4
5.0
3.5
9.7
3.9 12.8
5.1
3.5
10.1
4.0 13.2
5.3
4.0
10.4
4.0 13.4
5.2
4.0
10.9
4.2 14.0
5.4
Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
for 8 W
c
c
d
Spacing table 671009.752
Spacing table 671011.752
Spacing table 671586.752
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 450 lm, Emergency: 185 lm
Mains: 1350 lm, Emergency: 243 lm
Mains: 1350 lm, Emergency: 540 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
h
a
b
2.5
7.0
2.7
9.0
3.5
2.5
7.3
2.9
9.6
3.8
2.5
8.5
3.6 11.2
4.8
3.0
7.4
2.8
9.4
3.5
3.0
7.8
3.0 10.1
3.9
3.0
9.0
3.9 12.1
5.1
3.5
7.6
2.8
9.8
3.5
3.5
8.2
3.1 10.6
4.0
3.5
9.6
4.1 13.4
5.4
4.0
7.6
2.6 10.0
3.4
4.0
8.4
3.0 11.0
4.0
4.0
10.8
4.3 14.3
5.6
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
c
d
43
emergency Lighting | self-contained emergency luminaires Rechteck 250 / 360 / 485 Type of protection: IP 44
Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- High quality aluminium profile housing - Installation-friendly conctruction facilitates easy lamp replacement - Wide range of applications thanks to various types of installation - Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support - Available also with exceptionally long service life and energy efficient LED technology
1003
1004
1113
1115
1114
1116
- LED conversion sets are available for existing luminaires - All versions with downward light emission
Wall (surface)
44
Wall extension
1005
Ceiling (surface)
Pendant tube
Suspension cable/chain
emergency Lighting | self-contained emergency luminaires Series: Rechteck 250 Type of protection: IP 44 Protection class: I Viewing distance: 21 m For escape route identification Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides. Lamp included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
21 m
Available colours (X): 2 = white, 4 = aluminium, anodised
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
40
40
H
80
H
B
L
B
L
L
40
33
140
140 80
18
Article number
Type of installation
671045.00X.Y
12
12
11
55
Viewing distance
Luminous flux factor
Wall (surface)
21 m
-
671045.75X.Y
Wall (surface)
21 m
671049.00X.Y
Wall extension
21 m
671049.75X.Y
Wall extension
671053.00X.Y 671053.75X.Y
Ø6 9
80 68
41
6x12
40
6x18 40
41
40 250
Ø5
125 80
40
6x16
40
H H
B
L
LP
40 H
30
80
40
40
80
250
Lamp/Wattage
4x10
70
125
125
50
60
30
50
125
85 250
55
B
L
B
250
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
4 x LED 1 W
•
•
-
3h
L 250, B 125, H 140
-
1 x T16 (T5) 6 W
•
•
-
3h
L 250, B 125, H 140
-
4 x LED 1 W
•
•
-
3h
L 250, B 125, H 140
21 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 250, B 125, H 140
Ceiling (surface)
21 m
-
4 x LED 1 W
•
•
-
3h
L 250, B 125, H 140
Ceiling (surface)
21 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 250, B 125, H 140
671057.00X.Y
Pendant tube
21 m
-
4 x LED 1 W
•
•
-
3h
L 250, B 125, H 140, LP 500
671057.75X.Y
Pendant tube
21 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 250, B 125, H 140, LP 500
671343.00X.Y
Suspension cable/chain
21 m
-
4 x LED 1 W
•
•
-
3h
L 250, B 125, H 140
671343.75X.Y
Suspension cable/chain
21 m
-
1 x T16 (T5) 6 W
•
•
-
3h
L 250, B 125, H 140
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
45
emergency Lighting | self-contained emergency luminaires Series: Rechteck 360 Type of protection: IP 44 Protection class: I Viewing distance: 32 m For escape route identification Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides. Lamp included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
32 m
Available colours (X): 2 = white, 4 = aluminium, anodised
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
40
40
H
H
B
L
B
L
L
40
33
Ø6
40
125 9 11
12 192
6x16
6x18
40 362
40
H H
B
L
LP
40
40
H
30
80
40
40
80
40
12
Type of installation
671061.00X.Y
6x18 40
192
40
Ø5
Article number
Ø5 55
12
12
9
80 68
55
11
55
68 80
Viewing distance
Luminous flux factor
Wall (surface)
32 m
-
671061.75X.Y
Wall (surface)
32 m
671065.00X.Y
Wall extension
32 m
671065.75X.Y
Wall extension
671069.00X.Y 671069.75X.Y
Ø6
362
Lamp/Wattage
4x10
70
125
125
50
60
30
50
125
85 362
55
B
L
B
362
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
4 x LED 1 W
•
•
-
3h
L 362, B 125, H 192
-
1 x T16 (T5) 8 W
•
•
-
3h
L 362, B 125, H 192
-
6 x LED 1 W
•
•
-
3h
L 362, B 125, H 192
32 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 362, B 125, H 192
Ceiling (surface)
32 m
-
6 x LED 1 W
•
•
-
3h
L 362, B 125, H 192
Ceiling (surface)
32 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 362, B 125, H 192
671073.00X.Y
Pendant tube
32 m
-
6 x LED 1 W
•
•
-
3h
L 362, B 125, H 192, LP 500
671073.75X.Y
Pendant tube
32 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 362, B 125, H 192, LP 500
671347.00X.Y
Suspension cable/chain
32 m
-
6 x LED 1 W
•
•
-
3h
L 362, B 125, H 192
671347.75X.Y
Suspension cable/chain
32 m
-
1 x T16 (T5) 8 W
•
•
-
3h
L 362, B 125, H 192
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
46
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
emergency Lighting | self-contained emergency luminaires Series: Rechteck 485 Type of protection: IP 44 Protection class: I Viewing distance: 43 m For escape route identification Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides. Lamp included. Please specify legend number when ordering! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
43 m
Available colours (X): 2 = white, 4 = aluminium, anodised
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
40
40
H
40
40
H
H
H
B
L
B
L
33
Ø6
40
125 9 11
12 250
6x16
6x18
40 485
40
12
Type of installation
671077.00X.Y
6x18 40
250
40
Ø5
Article number
Ø5 55
12
12
11
55
68 80
Viewing distance
Luminous flux factor
Wall (surface)
43 m
-
671077.75X.Y
Wall (surface)
43 m
671081.00X.Y
Wall extension
43 m
671081.75X.Y
Wall extension
671085.00X.Y 671085.75X.Y
Ø6 9
80 68
55
485
Lamp/Wattage
B
L B
L
40
40
LP
H
B
L
30
80
40
40
80
70
4x10
60
125
125
50
55
50
85
485
30
50
125
50
485
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
4 x LED 1 W
•
•
-
3h
L 485, B 125, H 250
-
1 x T26 (T8) 15 W
•
•
-
3h
L 485, B 125, H 250
-
6 x LED 1,4 W
•
•
-
3h
L 485, B 125, H 250
43 m
-
1 x T26 (T8) 15 W
•
•
-
3h
L 485, B 125, H 250
Ceiling (surface)
43 m
-
6 x LED 1,4 W
•
•
-
3h
L 485, B 125, H 250
Ceiling (surface)
43 m
-
1 x T26 (T8) 15 W
•
•
-
3h
L 485, B 125, H 250
671089.00X.Y
Pendant tube
43 m
-
6 x LED 1,4 W
•
•
-
3h
L 485, B 125, H 250, LP 500
671089.75X.Y
Pendant tube
43 m
-
1 x T26 (T8) 15 W
•
•
-
3h
L 485, B 125, H 250, LP 500
671351.00X.Y
Suspension cable/chain
43 m
-
6 x LED 1,4 W
•
•
-
3h
L 485, B 125, H 250
671351.75X.Y
Suspension cable/chain
43 m
-
1 x T26 (T8) 15 W
•
•
-
3h
L 485, B 125, H 250
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Rated operat‑ Dimensions ing time
47
emergency Lighting | self-contained emergency luminaires
LED conversion kits It’s so easy to save money You can start right now to convert existing emergency luminaires of series Rechteck 250, 360 and 485 from incandescent or fluorescent lamp versions to LED versions. HOW? It‘s quite simple and easy: just use our LED conversion kits for self-contained emergency luminaires.
Accessories | Sets for converting luminaires for LED lamps Protection class: I Low-cost conversion of rectangular luminaires with T16 (or 8 W / 15 W) or common incandescent lamps into luminaires with energy-efficient, long-life LEDs. The conversion set can be clicked in any existing housing without needing to use any tool and can be connected to the existing power sup‑ ply cable. Modules’ plate: powder-coated aluminium sheet, ballasts and connecting terminal included. Monitoring function standard. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Sets for converting luminaires of series „Rechteck 250“ for LED lamps 981724.002 single sided/double sided 4 x LED 1 W/3h 981724.002.03 single sided/double sided 4 x LED 1 W/3h 981724.002.04 single sided/double sided 4 x LED 1 W/3h
Sets for converting luminaires of series „Rechteck 360“ for LED lamps 981726.002 single sided 4 x LED 1 W/3h 981726.002.03 single sided 4 x LED 1 W/3h 981726.002.04 single sided 4 x LED 1 W/3h 981728.002 double sided 6 x LED 1 W/3h 981728.002.03 double sided 6 x LED 1 W/3h 981728.002.04 double sided 6 x LED 1 W/3h
Sets for converting luminaires of series „Rechteck 485“ for LED lamps 981773.002 single sided 4 x LED 1 W/3h 981773.002.03 single sided 4 x LED 1 W/3h 981773.002.04 single sided 4 x LED 1 W/3h 981774.002 double sided 6 x LED 1,4 W/3h 981774.002.03 double sided 6 x LED 1,4 W/3h 981774.002.04 double sided 6 x LED 1,4 W/3h
Very easy „press and clip“ mounting. The conversion kit can be inserted in any existing luminaire housing without needing any tool NOR screws:
Just take the metal brackets ...
48
... press them together and ...
... click them into the luminaire housing.
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
emergency Lighting | self-contained emergency luminaires
Energy efficiency and costs Rechteck 360 in maintained mode (24h/day)
LED
Fluorescent lamp
Incandescent lamp
Lamp wattage
4W
8W
2 x 25 W
50,000 h
3 000 h
1,000 h
Total consumption in 1 year (8,760 h) in kWh
35.04 kWh
70.08 kWh
438.00 kWh
Power supply costs in 1 year (at 0.19 €/kWh)
6.66 €
13.32 €
83.22 €
175.20 kWh
350.40 kWh
2,190.00 kWh
33.29 €
66.58 €
416.10 €
0
14
43
0.00 €
107.10 €
118.68 €
Average time needed for replacing a lamp (minutes)
15 min.
10 min.
10 min.
Costs for replacing lamps (caretaker 25.00 €/h)
0.00 €
58.33 €
179.17 €
33.29 €
232.01 €
713.95 €
Service life in hours
Total consumption in 5 years (43,800 h) in kWh Power supply costs in 5 years (at 0.19 €/kWh) Number of lamps needed in 5 years (43,800 h) Costs for lamps in 5 years
Total costs in 5 years (power supply, lamps, lamp replacement)
The correct arrangement of the LEDs was calculated by our photometry lab, which allows us to minimize the number of LEDs, without impairing the required luminance values laid down in DIN 4844, Part 1 (luminance of more than 500 cd/m2 for the contrast colour). Thanks to a clever heat management, we are able to drastically reduce heat stress fort he LEDs, preventing thus an early LED failure. Average LED service life: approx. 50,000 hours!
Costs comparison over a period of 5 years
Incandescent lamps 2 x 25 W 713.95 €
= costs for power supply = costs for lamps = lamp replacement costs
T16 8W 232.01 €
LED 4W 33.29 €
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
49
emergency Lighting | self-contained emergency luminaires Multivariabel Type of protection: IP 54 - Industrial Design - IP 54 type of protection - dustproof and protected against water spray - Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support - Different types of installation for one sole luminaire - Lamp replacement without tools - Easy to install
Ceiling (surface), Wall (surface)
50
Ceiling (surface), Wall (surface)
Pendant tube
emergency Lighting | self-contained emergency luminaires Series: Multivariabel Type of protection: IP 54 for indoor use Protection class: I Viewing distance: 22 m For escape route identification or escape route illumination Base: aluminium, powder-coated; diffuser: plastic, opal, 3 Foils for escape route identification included. Lamp included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
22 m
Ceiling (surface), Wall (surface)
Pendant tube
LP
H L
H
B L
80
370
20
130
Ø6 40
30
Article number
40
30
Type of installation Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
671467.75X.Y 671368.75X.Y 671370.75X.Y
B
Pendant tube
45 50
4x14
Viewing distance
Luminous flux factor
-
32 %
22 m 22 m
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x T16 (T5) 8 W
•
•
-
3h
L 370, B 130, H 130
-
1 x T16 (T5) 8 W
•
•
-
3h
L 370, B 130, H 130
-
1 x T16 (T5) 8 W
•
•
-
3h
L 370, B 130, H 130, LP 500
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Replacement foils 991058
Replacement foil (Combi) for 21 m
Planning guide: Escape route illumination in accordance with EN 1838
Lamp luminous flux:
a b
Spacing table 671467.752
c
d
h
Mains: 450 lm, Emergency: 144 lm The following values are indicated in m h
a
b
c
d
2.5
4.8
1.5
6.2
2.0
3.0
4.6
1.1
6.0
1.7
3.5 - - - E = 1 lx along the centre line
4.0 - - - -
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
51
emergency Lighting | self-contained emergency luminaires Signcube Type of protection: IP 40 - Motifs on four sides - Plastic cube (PMMA) - Wide range of applications thanks to various types of installation - Optimum light distribution - Suspension can be shortened on site - Easy to install
Ceiling (surface), Wall (surface)
Special motifs in accordance with BGV A8
52
Pendant tube
Suspension cable/chain
emergency Lighting | self-contained emergency luminaires Series: Signcube Type of protection: IP 40 Protection class: I Viewing distance: 24 m For escape route identification Base: powder-coated metal; canopy: plastic, white; pendant tube: metal, chrome (can be shortened on site); diffuser: plastic (PMMA), opal; 3 foils included (according to DIN 4844). Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
24 m
Ceiling (surface), Wall (surface)
Pendant tube
Suspension cable/chain Ø108
B
B LP
H
H
H
L
L
B
255 190
L
255
60
10
30
110 255
Ø3,5
28
38
190 255
107
27
Article number
38
Ø10
Ø4,5x9
Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671605.92X.Y
Ceiling (surface), Wall (surface)
24 m
-
1 x TC-DEL 13 W
•
•
-
3h
L 255, B 255, H 276
671606.92X.Y
Pendant tube
24 m
-
1 x TC-DEL 13 W
•
•
-
3h
L 255, B 255, H 291, LP 510
671614.92X.Y
Suspension cable/chain
24 m
-
1 x TC-DEL 13 W
•
•
-
3h
L 255, B 255, H 300
Accessories | Legend foils in accordance with UVV BGV A8 and EECR 92/58 Viewing distance 48 m Replacement foils 991116 991117 991118
Motif foil 240 x 240 Motif foil 240 x 240 Motif foil 240 x 240
Motif 2003 Motif 2004 Motif 2005
2003
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
2004
2005
53
emergency Lighting | self-contained emergency luminaires GSUN® 2 / GSUN® 2 LED Type of protection: IP 44 - All-plastic luminaire, shockproof - Installation benefits for protections class II - 3 escape route motifs included - Low-cost installation
in addition for GSUN® 2 LED - Reliable and long life LED technology - LED service life: approx. 50,000 hours - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - Very low current consumption
GSUN® 3 / GSUN® 4 Type of protection: IP 54 - All-plastic luminaire, shockproof - IP 54 type of protection - dustproof and protected against water spray - Can be used for all types of installation (with accessories) - Low current consumption - 3 escape route motifs included - Low-cost installation
GSUN® 3 LED / GSUN® 4 LED Schutzart: IP 54 - All-plastic luminaire, shockproof - IP 54 type of protection - dustproof and protected against water spray - Can be used for all types of installation (with accessories) - Reliable and long life LED technology - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - LED service life: approx. 50,000 hours - 3 escape route motifs included - Low-cost installation - 8 h version Wall (surface) GSUN® 2
54
Wall (surface) GSUN® 2 LED
Ceiling (surface), Wall (surface) GSUN® 3 / GSUN® 3 LED
Ceiling (surface), Wall (surface) GSUN® 4 / GSUN® 4 LED
Wall (surface) GSUN® 4 / GSUN® 4 LED
emergency Lighting | self-contained emergency luminaires Series: GSUN® 2
Series: GSUN® 2 LED
Type of protection: IP 43 Protection class: II Viewing distance: 19 m
Type of protection: IP 40 Protection class: II Viewing distance: 19 m
For escape route identification
For escape route identification
Base: plastic. Diffuser: plastic, opal. Combination foil with black rescue symbols included. Lamps included (2 x D11 0.5 W and 1 x CO16 5 W).
Base: plastic. Diffuser: plastic, opal. Combination foil with escape route motif included. LED included.
Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS).
Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS).
19 m
Available colour: black
19 m
Available colour (X): 9 = grey
Wall (surface)
Wall (surface)
H
H
B
B
L
L
214
214
25
114 85
85
25
85
6x10
Article number
Type of installation
65133 671817.00X.Y
25
114
Viewing distance
Luminous flux factor
Wall (surface)
19 m
-
Wall (surface)
19 m
-
Lamp/Wattage
85
25 6x10
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x CO16 5 W + 2 x D11 0.5 W
-
-
-
3h
L 215, B 115, H 110
LED 0.2 W
-
-
-
3h
L 215, B 115, H 110
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
55
emergency Lighting | self-contained emergency luminaires Series: GSUN® 3 Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m For escape route identification or escape route illumination Base: plastic; diffuser: plastic, opal, motif foil included, lamp included, test button incorporated in standard version. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast emergency/mains: EB Available colour (X): 2 = white
21 m
Accessories | Kits for converting luminaires for LED lamps Protection class: I
Ceiling (surface), Wall (surface) (high hood)
Ceiling (surface), Wall (surface) (flat hood)
Operating mode: non-maintained or maintained.
H
H L
Low-cost solution for converting existing GSUN® 3 luminaires with T16 6 W (or 8 W / 15 W) into lumi‑ naires with energy-efficient, longlife LEDs. The conversion kit can be installed in any existing housing and can be connected to the existing power supply cable.
B
L
B
Planning guide: Escape route illumination in accordance with EN 1838 a c
b
5x11
5x11
70
13
100
13 80
70
100 240
h
13
100
126
13 80
d
126
100 240
E = 1 lx along the centre line
Article number
Type of installation
671574.75X.Y
Wall (surface)
Viewing distance
Luminous flux factor
21 m
33 %
Lamp/Wattage 1 x T16 (T5) 6 W
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
•
•
-
Rated operat‑ Dimensions ing time
with automatic self-test function, without feedback
3h
L 240, B 126, H 78
3h
L 240, B 126, H 78
671639.75X.Y
Wall (surface)
21 m
38 %
1 x T16 (T5) 6 W
671520.00X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x CO26 15 W + 2 x D11 0,5 W
-
-
-
3h
L 240, B 126, H 145
671321.75X.Y
Ceiling (surface), Wall (surface)
21 m
33 %
1 x T16 (T5) 6 W
•
•
-
3h
L 240, B 126, H 145
671618.75X.Y
Ceiling (surface), Wall (surface)
21 m
38 %
1 x T16 (T5) 6 W
3h
L 240, B 126, H 145
with automatic self-test function, without feedback
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185 Accessories | Wall extension Steel, white powder-coated Wall extension 981144.002
L 251, B 131, H 60 Spacing table 671321.752
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
LP 500 mm
Lamp luminous flux: Mains: 300 lm, Emergency: 108 lm The following values are indicated in m h
a
b
c
d
2.5
3.3
1.1
4.3
0.7
3.0 - - - Kit for converting GSUN® 3 for LED lamps 981781.000 1 x LED 2,1 W/3h
56
3.5 - - - 4.0 - - - -
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
emergency Lighting | self-contained emergency luminaires Series: GSUN® 3 LED Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m For escape route identification Base: plastic. Diffuser: plastic, opal. Combination foil with three rescue symbols included. LED included. Test button integrated in standard version. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
21 m
Ceiling (surface), Wall (surface) (high hood)
Ceiling (surface), Wall (surface) (flat hood)
H
H L
B
5x11
5x11
70
13
100
13 80
B
L
13
100
126
100 240
13 80
Article number
Type of installation
671707.00X.Y
70
126
100 240
Viewing distance
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
Wall (surface)
21 m
-
1 x LED 2,1 W
•
•
-
3h
L 240, B 126, H 78
671908.00X.Y
Wall (surface)
21 m
-
1 x LED 2,1 W
-
•
-
8h
L 240, B 126, H 78
671780.00X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x LED 2,1 W
•
•
-
3h
L 240, B 126, H 145
671909.00X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x LED 2,1 W
-
•
-
8h
L 240, B 126, H 145
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185 Accessories | Wall extension Steel, white powder-coated Wall extension 981144.002
L 251, B 131, H 60
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
LP 500 mm
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
57
emergency Lighting | self-contained emergency luminaires Series: GSUN® 4 Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m, 25 m For escape route identification or escape route illumination Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: transparent plastic (polycarbonate), prismatic; motif foils included; test button integrated in standard version. Lamp included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
21 m/25 m
Accessories | Kits for converting luminaires for LED lamps
Available colour (X): 2 = white
Protection class: I
Ceiling (surface), Wall (surface) (high hood) opal
Low-cost solution for converting existing GSUN® 4 luminaires with T16 6 W (or 8 W / 15 W) into lumi‑ naires with energy-efficient, longlife LEDs. The conversion kit can be installed in any existing housing and can be connected to the existing power supply cable.
Ceiling (surface), Wall (surface) (flat hood) transparent, prismatic
Operating mode: non-maintained or maintained.
H L
B
Planning guide: Escape route illumination in accordance with EN 1838 a c
b
5x11
15
148,5 110
5x11 50 144
112,5
148,5 110
15
h
50 144
112,5
250 344
d
250 344
E = 1 lx along the centre line
Article number
Type of installation
Viewing distance
Luminous flux factor
25 m
32 %
Lamp/Wattage
671515.75X.Y
Ceiling (surface), Wall (surface)
671619.75X.Y
Ceiling (surface), Wall (surface)
25 m
32 %
1 x T16 (T5) 8 W
671517.75X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x T16 (T5) 8 W
671620.75X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x T16 (T5) 8 W
1 x T16 (T5) 8 W
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Accessories | Wall extension Steel bracket, white powder-coated Wall extension 981485.002
L 374, B 147, H 75
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
LP 500 mm
Mounting kit for chains/cable suspensions 981583.002
PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
•
•
-
Rated operat‑ Dimensions ing time
with automatic self-test function, without feedback •
•
-
with automatic self-test function, without feedback
3h
L 344, B 144, H 78
3h
L 344, B 144, H 78
3h
L 344, B 144, H 148
3h
L 344, B 144, H 148
Spacing table 671515.752
Lamp luminous flux: Mains: 450 lm, Emergency: 157 lm The following values are indicated in m h
a
b
c
d
2.5
5.7
2.3
7.2
2.6
3.0
6.3
2.3
7.4
2.6
3.5
5.7
2.3
7.0
2.5
4.0
6.5
2.1
7.1
2.1
Spacing table 671517.752
Lamp luminous flux: Mains: 450 lm, Emergency: 157 lm The following values are indicated in m h
a
b
c
d
2.5
5.5
1.9
6.9
2.5
3.0
4.9
1.6
6.1
2.3
3.5
4.4
1.1
6.4
1.8
4.0 - - - Kit for converting GSUN® 4 for LED lamps 981771.000 1 x LED 4,5 W/3h
58
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
emergency Lighting | self-contained emergency luminaires Series: GSUN® 4 LED Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m, 25 m For escape route identification Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: transparent plastic (polycarbonate), prismatic, motif foil included, test button integrated in standard version. LED included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
21 m/25 m
Available colour (X): 2 = white
Ceiling (surface), Wall (surface) (high hood) opal
Ceiling (surface), Wall (surface) (flat hood) transparent, prismatic
H
H L
5x11
L
B
15
148,5 110
5x11 50 144
112,5
148,5 110
15
50 144
112,5
250 344
Article number
B
250 344
Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671792.00X.Y
Wall (surface)
25 m
-
1 x LED 4,5 W
•
•
-
3h
L 344, B 144, H 78
671906.00X.Y
Wall (surface)
25 m
-
1 x LED 4,5 W
•
•
-
8h
L 344, B 144, H 78
671819.00X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x LED 4,5 W
•
•
-
3h
L 344, B 144, H 148
671907.00X.Y
Ceiling (surface), Wall (surface)
21 m
-
1 x LED 4,5 W
•
•
-
8h
L 344, B 144, H 148
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Accessories | Wall extension Steel bracket, white powder-coated Wall extension 981485.002
L 374, B 147, H 75
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
LP 500 mm
Mounting kit for chains/cable suspensions 981583.002
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
59
emergency Lighting | self-contained emergency luminaires LCS1 Type of protection: IP 40 - Extremely flat housing - Reflector inside - Lamp replacement without tools - Easy to mount - Large viewing distance - Easy to install
Ceiling (surface), Wall (surface)
60
Wall (surface)
emergency Lighting | self-contained emergency luminaires Series: LCS1
Series: LCS3
Type of protection: IP 40 Protection class: II Viewing distance: 35 m
Type of protection: IP 40 Protection class: II (I for .04) Viewing distance: 35 m
For escape route identification or escape route illumination (escape route identification only for Wall (surface).)
For escape route identification or escape route illumination (escape route identification only for Wall (surface).)
Base and reflector: plastic (polycar‑ bonate). Refractor: plastic (PMMA), transparent. Function monitoring and test button: standard. Lamp included.
Base and reflector: plastic (polycarbo‑ nate). Refractor: plastic (PMMA), trans‑ parent. Three foils with escape legends included. Function monitoring and test button integrated in standard version. Lamp included. Operating mode: Can either be connec‑ ted in non-maintained power mode (BS) or in maintained power mode (DS).
35 m
Please note: Luminaire is only available for opera‑ tion in non-maintained power mode. It cannot be modified. Motifs sets are to be ordered separately.
Ballast mains/emergency: EB Available colour (X): 2 = white
Ballast: EB Available colour (X): 2 = white Ceiling (surface), Wall (surface)
Ceiling (surface), Wall (surface)
H
H
B
L
202
16
202
16
80 174
18
250 371
Article number
250 371
Type of installation Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)
671608.75X.Y 671609.75X.Y
Replacement foils 991112
Viewing distance
Luminous flux factor
35 m
36 %
35 m
38 %
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x T16 (T5) 8 W
-
-
-
1h
L 398, B 62, H 202
1 x T16 (T5) 8 W
•
•
-
3h
L 398, B 62, H 202
Set of rescue symbols 2003, 2004 and 2005, viewing distance 35 m
Planning guide: Escape route illumination in accordance with EN 1838 a b
Ø5
398
80 174
18
B
L
Ø5
398
35 m
c
d
h
E = 1 lx along the centre line
Spacing table 671608.752
Spacing table 671609.752
Lamp luminous flux:
Lamp luminous flux:
Mains: 400 lm, Emergency: 140 lm
Mains: 400 lm, Emergency: 140 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
5.9
2.2
8.7
3.2
2.5
2.7
7.9
6.7
5.5
3.0
6.2
2.2
9.0
2.9
3.0
2.4
8.0
6.7
5.7
3.5
6.4
2.2
9.1
2.6
3.5
1.9
7.8
6.5
5.8
4.0
6.5
2.1
8.8
2.2
4.0
1.7
7.2
6.2
5.8
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
61
emergency Lighting | self-contained emergency luminaires Varioplast I Type of protection: IP 54 - Ultraflat design - IP 54 type of protection - dustproof and protected against water spray - Installation-friendly construction: folding mounting plate with lampholder and ballast - Shockproof verison - Compact design - Multi-purpose applications
Ceiling (surface), Wall (surface)
62
Wall (surface)
emergency Lighting | self-contained emergency luminaires Series: Varioplast I Type of protection: IP 54 for indoor use Protection class: I Viewing distance: 24 m For escape route identification (only in case of Wall (recessed)) or escape route illumination Base: plastic (polycarbonate); refractor: plastic (polycarbonate), transparent, prismatic inside, 3 foils for escape route identification included. Lamp included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB
24 m
Available colours (X): 2 = white, 3 = black
Ceiling (surface), Wall (surface)
H
B
L
6
320 288
16
148
30
154 80
16
116 186
27
115
Article number
5x8
Type of installation
671113.75X.Y
Wall (surface)
671111.75X.Y
Ceiling (surface), Wall (surface)
Viewing distance
Luminous flux factor
24 m
-
-
33 %
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x T16 (T5) 6 W
•
•
-
3h
L 320, B 80, H 186
1 x T16 (T5) 6 W
•
•
-
3h
L 320, B 80, H 186
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Accessories | Set of screws with special anti-theft key 90-4013.002 white 90-4013.003 black
Accessories | Wire guard, varnished 22125.002 L 314, B 180, H 49 22125.003 L 314, B 180, H 49
Planning guide: Escape route illumination in accordance with EN 1838
Spacing table 671111.75X
Lamp luminous flux:
a b
white black
c
d
h
E = 1 lx along the centre line
Mains: 300 lm, Emergency: 108 lm The following values are indicated in m h
a
b
c
d
2.5
5.3
2.0
6.0
2.2
3.0
5.3
1.9
6.1
2.1
3.5
5.0
1.7
5.7
1.8
4.0
5.3
1.3
4.9
1.4
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
63
emergency Lighting | self-contained emergency luminaires Space Type of protection: IP 40 - Shockproof housing in flat, elegant design - Installation-friendly construction - Easy lamp replacement - Theft protection: quick mount adaptor with lock system - Reflector inside - Functional design
Ceiling (surface), Wall (surface)
64
emergency Lighting | self-contained emergency luminaires Series: Space Type of protection: IP 40 Protection class: II Viewing distance: 20 m, 25 m For escape route identification (only in case of wall installation) or escape route illumination Base: plastic, grey. Refractor: plastic (polycarbonate), transparent, prismatic. Patented quick mount adaptor. 3 plastic foils and lamp included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 9 = grey
20 m/25 m
Ceiling (surface), Wall (surface)
Ceiling (surface), Wall (surface)
B
B
H
H
L
L
374 344 65
280 254 65
40
130 104 170
Article number
40
164 134
60
5x10
Type of installation
170 240
Viewing distance
Luminous flux factor
5x10
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
67924.75X.Y
Ceiling (surface), Wall (surface)
20 m
54 %
1 x T16 (T5) 6 W
-
-
-
3h
L 280, B 130, H 53
67923.75X.Y
Ceiling (surface), Wall (surface)
25 m
58 %
1 x T16 (T5) 8 W
-
-
-
3h
L 374, B 164, H 70
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185 981168.002 L 540, B 375, H 185
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
for 6 W for 8 W
Spacing table 67923.750
Spacing table 67924.750
Lamp luminous flux:
Lamp luminous flux:
Mains: 450 lm, Emergency: 225 lm
Mains: 300 lm, Emergency: 150 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
6.3
2.3
5.7
2.2
2.5
6.2
2.3
5.6
2.1
3.0
6.1
2.4
5.8
2.3
3.0
6.1
2.1
5.3
2.2
3.5
5.6
2.0
5.9
2.3
3.5
5.8
2.0
5.7
2.1
4.0
5.7
1.7
5.8
1.9
4.0
5.2
1.6
6.0
1.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
65
emergency Lighting | self-contained emergency luminaires Universum Type of protection: IP 40 - Shockproof housing in flat, elegant design - Installation-friendly construction - Easy lamp replacement - Theft protection: quick mount adaptor with lock system - Reflector inside - Functional design
Ceiling (surface), Wall (surface)
66
emergency Lighting | self-contained emergency luminaires Series: Universum Type of protection: IP 40 Protection class: II Viewing distance: 20 m For escape route identification or escape route illumination Base: plastic, white. Refractor: plastic (polycarbonate), transparent, prismatic. Patented quick mount adaptor. 3 foils and lamp included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 9 = grey
20 m
Ceiling (surface), Wall (surface)
B
H L
360 347 65
40
115 104 5x10
170
Article number
Type of installation
Viewing distance
Luminous flux factor
20 m
37 %
Ceiling (surface), Wall (surface)
671116.75X.Y
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
-
-
-
1 x T16 (T5) 8 W
Rated operat‑ Dimensions ing time 3h
L 360, B 115, H 52
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Accessories | Recessed housing with cover frame Recess dimensions: 410 x 145 mm, depth 52 mm Recessed housing with cover frame 67006.009 L 415, B 165, H 44, HE 52 Accessories | Escape route identification for surface ceiling mounting or recessed ceiling mounting (recessed ceiling mounting in connection with 67006.009). Display dimensions: L 310, B 155 mm, viewing distance : 30 m Accessories | Escape route identification 67004.009 Escape route right/left 67005.009 Emergency exit
Planning guide: Escape route illumination in accordance with EN 1838
Lamp luminous flux:
a b
Spacing table 671116.750
c
d
h
E = 1 lx along the centre line
Mains: 450 lm, Emergency: 167 lm The following values are indicated in m h
a
b
c
d
2.5
6.4
2.3
6.0
2.2
3.0
6.6
2.3
6.0
2.3
3.5
6.4
2.0
6.0
2.2
4.0
6.4
1.6
6.2
1.8
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
67
emergency Lighting | self-contained emergency luminaires Turia Type of protection: IP 30 - Wide luminaire spacing for escape route illumination - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install - Compact design - Inconspicuous design - The single-battery module and storage battery can be inserted and removed through the ceiling opening
Ceiling (recessed)
68
emergency Lighting | self-contained emergency luminaires Series: Turia Type of protection: IP 30 Protection class: II Ceiling thickness: 15-35 mm For escape route illumination Housing: die-cast aluminium. Bezel ring: plastic, white. Module and battery in separate ballast box with connecting cable. Automatic self test in all standard versions. LED included. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
Ceiling (recessed)
HE H
DA D
Ø50
Ø42
Article number
Type of installation
Operating mode BS / DS
Luminous flux factor
671920.00X.Y
Ceiling (recessed)
BS
100 %
671921.00X.Y
Ceiling (recessed)
BS / DS
100 %
Planning guide: Escape route illumination in accordance with EN 1838
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
1 x LED 2 W
-
-
•
3h
1 x LED 2 W
-
-
•
3h
Spacing table 671920.00X und 671921.00X
Rated operat‑ Dimensions ing time
Step 1
Step 2
Step 3
Step 4
D 50, H 2 DA 42, HE 45 D 50, H 2 DA 42, HE 45
Lamp luminous flux:
a b
Lamp/Wattage
c
d
h
E = 1 lx along the centre line
Mains: 148 lm, Emergency: 148 lm The following values are indicated in m h
a
b
c
d
2.5
7.3
3.0
7.3
3.0
3.0
8.2
3.4
8.2
3.4
3.5
8.9
3.6
8.9
3.6
4.0
9.5
3.7
9.5
3.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
69
emergency Lighting | self-contained emergency luminaires Edo Type of protection: IP 20 - Wide luminaire spacing for escape route illumination - Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology) - Top quality LED technology
Example
- Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install - Compact design - Inconspicuous design
+ + =
Edo 4
70
Edo 5
Edo 1 Installation in existing luminiares
Edo 2 Installation in metal ceilings
emergency Lighting | self-contained emergency luminaires Series: Edo Type of protection: IP 30 Protection class: II Ceiling thickness: 1-8 mm (Edo 1 and Edo 2) Ceiling thickness: 15-35 mm (Edo 4 and Edo 5) For escape route illumination Housing: die-cast aluminium, bezel ring: plastic, white, (only Edo 4 + 5), separate ballast box with connection cable. Automatic self test in all standard versions. LED included. Operating mode: Can be ordered either for non-maintained (BS) or maintained (DS). Ballast mains/emergency: EB Luminous flux factor 100% Available colours (X): 2 = white (Edo 4 and Edo 5), 4 = aluminium (Edo 1 and Edo 2) Edo 1
Edo 2
Edo 4
Edo 5
LA L
D
D
HE
DA
DA
H
DA D
H
Ø50
Article number
Type of installation
671931.00X.Y
HE
HE
HE
H
Operating mode BS / DS
Type
Lamp/Wattage
Retrofitting kit
BS
Edo 1
671932.00X.Y
Retrofitting kit
BS / DS
671933.00X.Y
BS
671934.00X.Y
Installation in metal ceilings Installation in metal ceilings
671927.00X.Y
Ceiling (recessed)
671928.00X.Y 671929.00X.Y 671930.00X.Y
BA B
Ø40
Ø50
H
Ø40
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x LED 2 W
-
-
•
3h
D 22, H 8, DA 10.5, HE 15
Edo 1
1 x LED 2 W
-
-
•
3h
D 22, H 8, DA 10.5, HE 15
Edo 2
1 x LED 2 W
-
-
•
3h
D 27, H 1, DA 22, HE 23
BS / DS
Edo 2
1 x LED 2 W
-
-
•
3h
D 27, H 1, DA 22, HE 23
BS
Edo 4
1 x LED 2 W
-
-
•
3h
D 50, H 3, DA 40, HE 45
Ceiling (recessed)
BS / DS
Edo 4
1 x LED 2 W
-
-
•
3h
D 50, H 3, DA 40, HE 45
Ceiling (recessed)
BS
Edo 5
1 x LED 2 W
-
-
•
3h
L 50, B 50, H 3, DA 40, HE 45
Ceiling (recessed)
BS / DS
Edo 5
1 x LED 2 W
-
-
•
3h
L 50, B 50, H 3, DA 40, HE 45
Edo 1 Accessories | Fixing bracket for Edo 1 Bracket for fixing Edo 1 into recessed luminiares such as downlights or louvre luminaires. Bracket is to be installed in existing reflector or louvre. Fixing bracket for Edo 1 981778.000 L 25, B 19, H 22
Planning guide: Escape route illumination in accordance with EN 1838
Edo 2
Lamp luminous flux:
a b
Table applies to all Edo series luminaires
Spacing table 671931.004
c
d
h
E = 1 lx along the centre line
Mains: 109 lm, Emergency: 109 lm The following values are indicated in m h
a
b
c
d
2.5
7.7
3.0
7.7
3.0
3.0
8.5
3.2
8.5
3.2
3.5
8.9
3.2
8.9
3.2
4.0
9.1
3.2
9.1
3.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
71
emergency Lighting | self-contained emergency luminaires Lucio Type of protection: IP 40 - Wide luminaire spacing for escape route illumination - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Compact design - Easy to install - Wide range of applications thanks to either surface or recessed ceiling installation
Ceiling (surface)
72
Ceiling (recessed)
emergency Lighting | self-contained emergency luminaires Series: Lucio Type of protection: IP 40 Protection class: II Ceiling thickness: 5-25 mm For escape route illumination Housing: plastic. Accessories for recessed and surface mounting on the ceiling are included. Automatic self test in all standard versions. LED included. Operating mode: non-maintained power mode (BS) Ballast: EB 2 lenses included in article number 671918.00X.Y. Available colour (X): 2 = white
Ceiling (surface)
Ceiling (recessed)
D
HE
104
H
DA D
H
25
8)
(7
Ø4,2
51 73,5
Ø16
Ø4,2
Ø120
Ø105
59 Ø120
Article number
Type of installation
Type
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671917.00X.Y
Ceiling (surface), Ceiling (recessed)
without lenses
100%
1 x LED 3 W
-
-
•
3h
Surface installation: D 120, H 45
671918.00X.Y
Ceiling (surface), Ceiling (recessed)
with lenses
100%
1 x LED 3 W
-
-
•
3h
Recessed installation: D 120, H 3, DA 105, HE 42
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671917.002
Spacing table 671918.002
Lamp luminous flux:
Lamp luminous flux:
Mains: 82 lm, Emergency: 82 lm
Mains: 100 lm, Emergency: 100 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
5.3
2.1
5.3
2.1
2.5
7.1
3.0
4.3
1.6
3.0
5.9
2.1
5.9
2.1
3.0
8.0
3.3
4.5
1.6
3.5
6.3
1.9
6.3
1.9
3.5
8.7
3.6
4.6
1.7
4.0
6.4
1.5
6.4
1.5
4.0
9.3
3.8
4.8
1.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
73
emergency Lighting | self-contained emergency luminaires Centryxx Type of protection: IP 40 - Wide luminaire spacing for escape route illumination - Design matches modern architectural styles - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install
Ceiling (surface)
74
Ceiling (recessed), square
Ceiling (recessed), round
emergency Lighting | self-contained emergency luminaires Series: Centryxx Type of protection: IP 20 (Ceiling (surface)), IP 40 (Ceiling (recessed)) Protection class: I For escape route illumination Housing: die-cast aluminium, powder-coated; plastic diffuser for ideal light distribution on escape route. Automatic self test in all standard versions. LED included. Operating mode: non-maintained power mode (BS) Ballast mains/emergency: EB Available colour (X): 2 = white
Ceiling (surface)
Ceiling (recessed), square
Ceiling (recessed), round
B
B
HE
HE
L
H
DA L
H
DA D
H
51
180
Ø5
220
90
Ø185
Ø200
Ø185
Ø5
220
90 180
Article number
Type of installation
Type
Luminous flux factor
671840.00X.Y
Ceiling (surface)
square
100 %
1 x LED 3 W
671838.00X.Y
Ceiling (recessed)
square
100 %
1 x LED 3 W
671836.00X.Y
Ceiling (recessed)
round
100 %
1 x LED 3 W
Planning guide: Escape route illumination in accordance with EN 1838
c
d
h
E = 1 lx along the centre line
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
with automatic self-test function, without feedback
Rated operat‑ Dimensions ing time 3h
L 180, B 180, H 27
3h
L 220, B 220, H 3, DA 185, HE 73
3h
D 200, H 3 DA 185, HE 73
Table applies to all Centryxx series luminaires
Spacing table 671840.002
Lamp luminous flux:
a b
Lamp/Wattage
Mains: 180 lm, Emergency: 180 lm The following values are indicated in m h
a
b
2.5
3.4
0.9 12.6
c
5.6
d
3.0
3.0
0.8 14.2
6.4
3.5
2.6
0.7 16.1
7.1
4.0
2.4
0.0 10.5
0.0
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
75
emergency Lighting | self-contained emergency luminaires Energo TC 175 Type of protection: IP 23 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Housing made of top quality die-cast aluminium - Wide luminaire spacing for escape route illumination - Modern design - Bezel ring made of die-cast aluminium - Infinitely adjustable spring fastening system - EBs in separate ballast box - Modular recessed luminaire with small recessed depth - Easy to install - For ceiling thicknesses of 1-40 mm
Ceiling (recessed)
76
emergency Lighting | self-contained emergency luminaires Series: Energo TC 175 Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Ceiling thickness: 1-40 mm For escape route illumination Modular design: A bezel ring must always be ordered for each basic luminaire! Recess and bezel ring: die-cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: aluminium, highly polished anodised finish; installation in ceiling with spring system. EB in separate ballast box with connection cable (L 400 mm) in flexible hose; 5-pole double terminal for through-wiring. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X) Basic luminaire: 4 = silver metallic
Ceiling (recessed)
HE H
DA D
Ø188
Ø175
Article number
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
671873.92X.Y
Ceiling (recessed)
1/1
18 %
671875.92X.Y
Ceiling (recessed)
2/1
671874.96X.Y
Ceiling (recessed)
671876.96X.Y
Ceiling (recessed)
Moulded housing 981656.000
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
1 x TC-DEL 13 W
•
•
-
3h
D 188, H 4 DA 175, HE 100
18 %
2 x TC-DEL 13 W
•
•
-
3h
D 188, H 4 DA 175, HE 100
1/1
15 %
1 x TC-DEL 18 W
•
•
-
3h
D 188, H 4 DA 175, HE 100
2/1
15 %
2 x TC-DEL 18 W
•
•
-
3h
D 188, H 4 DA 175, HE 100
Moulded housing
Lamp/Wattage
Rated operat‑ Dimensions ing time
L 500, B 250, H 160 mm
Panel mounting frame 98102.002/176 Panel mounting frame
Dimensions 285 x 285 mm
Bezel rings with safety glass, D 194 mm, H 9 mm 981653.002 Safety glass, transparent 981653.004 Safety glass, transparent Bezel rings without safety glass, D 194 mm, H 9 mm 981653.102 981653.104
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671873.92X und 671875.92X
Spacing table 671874.96X und 671876.96X
Lamp luminous flux:
Lamp luminous flux:
Mains: 900 lm, Emergency: 162 lm
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
7.7
2.8
7.7
2.8
2.5
7.5
2.9
7.5
2.9
3.0
8.1
2.9
8.1
2.9
3.0
8.1
3.1
8.1
3.1
3.5
8.4
2.8
8.4
2.8
3.5
8.5
3.0
8.5
3.0
4.0
8.3
2.7
8.3
2.7
4.0
8.7
3.0
8.7
3.0
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
77
emergency Lighting | self-contained emergency luminaires Energo TC 210 Type of protection: IP 23 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Housing made of top quality die-cast aluminium - Wide luminaire spacing for escape route illumination - Modern design - Bezel ring made of die-cast aluminium - Infinitely adjustable spring fastening system - EBs in separate ballast box - Modular recessed luminaire with small recessed depth - Easy to install - For ceiling thicknesses of 1-40 mm
Ceiling (recessed)
78
emergency Lighting | self-contained emergency luminaires Series: Energo TC 210 Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Ceiling thickness: 1-40 mm For escape route illumination Modular design: A bezel ring must always be ordered for each basic luminaire! Recessed and bezel ring: die-cast aluminium; bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑ nium, highly polished anodised finish; installation in ceiling with spring system. EB in separate ballast box wit connection cable L 400 mm in flexible hose, 5-pole double terminal for through-wiring. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X) Basic luminaire: 4 = silver metallic
Ceiling (recessed)
HE H
DA D
Ø220
Ø210
Article number
Type of installation
671881.83X.Y 671882.83X.Y
Moulded housing 981662.000
Lamps Mains/ Emergency
Luminous flux factor
Ceiling (recessed)
1/1
14 %
Ceiling (recessed)
2/1
14 %
Moulded housing
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x TC-TEL 32 W
•
•
-
3h
D 220, H 4 DA 210, HE 120
2 x TC-TEL 32 W
•
•
-
3h
D 220, H 4 DA 210, HE 120
L 450, B 300, H 200 mm
Panel mounting frame 98102.002/215 Panel mounting frame
Dimensions 285 x 285 mm
Bezel rings with decorative attachment, D 250 mm, H 38 mm 981660.002 Decorative glass, transparent 981660.004 Decorative glass, transparent Bezel rings with safety glass, D 227 mm, H 9 mm 981659.002 Safety glass, transparent 981659.004 Safety glass, transparent Planning guide: Escape route illumination in accordance with EN 1838
Lamp luminous flux:
a b
Spacing table 671881.83X und 671882.83X
c
d
h
E = 1 lx along the centre line
Mains: 1800 lm, Emergency: 252 lm The following values are indicated in m h
a
b
c
d
2.5
9.4
3.8
9.4
3.8
3.0
10.3
4.1 10.3
4.1
3.5
11.0
4.1 11.0
4.1
4.0
11.5
4.1 11.5
4.1
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
79
emergency Lighting | self-contained emergency luminaires Andho TC Type of protection: IP 23 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Housing made of top quality die-cast aluminium - Top quality reflector made of aluminium, highly polished anodised finish
Ceiling (surface)
80
emergency Lighting | self-contained emergency luminaires Series: Andho TC Type of protection: IP 23 Protection class: I For escape route illumination Housing: aluminium extrusion profile, powder-coated; bezel ring and ceiling base: die-cast aluminium, powder-coated, with bayonet fixing; reflector: aluminium, highly polished anodised finish; EB incorporated, 5 pole double terminal for through-wiring. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colours (X): 2 = white, 4 = silver metallic
Ceiling (surface)
D
H
Ø230 Ø7 178
45 178
Article number
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
671891.84X.Y
Ceiling (surface)
1/1
14 %
671892.84X.Y
Ceiling (surface)
2/1
14 %
Planning guide: Escape route illumination in accordance with EN 1838
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x TC-TEL 18 W
•
•
-
3h
D 230, H 278
2 x TC-TEL 18 W
•
•
-
3h
D 230, H 278
Spacing table 671891.84X und 671892.84X
Lamp luminous flux:
a b
Lamp/Wattage
c
d
h
E = 1 lx along the centre line
Mains: 1200 lm, Emergency: 168 lm The following values are indicated in m h
a
b
c
d
2.5
7.7
3.0
7.7
3.0
3.0
8.5
3.3
8.5
3.3
3.5
9.0
3.3
9.0
3.3
4.0
9.3
3.3
9.3
3.3
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
81
emergency Lighting | self-contained emergency luminaires Andho TC IP 65 Type of protection: IP 65 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Housing made of top quality die-cast aluminium - Top quality reflector made of aluminium, highly polished anodised finish
Ceiling (surface)
82
emergency Lighting | self-contained emergency luminaires Series: Andho TC IP 65 Type of protection: IP 65 for indoor use Protection class: I For escape route illumination Housing: aluminium extrusion profile, powder-coated; ceiling base: die-cast aluminium, powder-coated, with bayonet fixing; bezel ring: powder-coated die-cast aluminium, screwed on the luminaire; safety glass, transparent; reflector: aluminium, highly polished anodised finish; EB incorporated, 5 pole double terminal for through-wiring. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colours (X): 2 = white, 4 = silver metallic
Ceiling (surface)
D
H
Ø230 Ø7 178
45 178
Article number
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
671893.84X.Y
Ceiling (surface)
1/1
14 %
671894.84X.Y
Ceiling (surface)
2/1
14 %
Planning guide: Escape route illumination in accordance with EN 1838
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x TC-TEL 18 W
•
•
-
3h
D 230, H 290
2 x TC-TEL 18 W
•
•
-
3h
D 230, H 290
Spacing table 671893.84X und 671894.84X
Lamp luminous flux:
a b
Lamp/Wattage
c
d
h
E = 1 lx along the centre line
Mains: 1200 lm, Emergency: 168 lm The following values are indicated in m h
a
b
c
d
2.5
7.6
2.9
7.6
2.9
3.0
8.2
3.2
8.2
3.2
3.5
8.7
3.2
8.7
3.2
4.0
9.0
3.2
9.0
3.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
83
emergency Lighting | self-contained emergency luminaires Arelo速 Type of protection: IP 20 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Recessed ring made of die-cast aluminium - Top quality reflector made of aluminium, highly polished anodised finish - Wide beam light distribution - All versions with EB in separate ballast box - Simple spring system for installation without tools
Ceiling (recessed)
84
emergency Lighting | self-contained emergency luminaires Series: Arelo® Type of protection: IP 20 Protection class: I Ceiling thickness: 1-25 mm For escape route illumination Recess ring: die-cast aluminium, powder-coated; bracket: galvanised sheet steel; reflector: aluminium, highly polished ano‑ dised finish; separate ballast box, length of cable between luminaire and ballast box: 400 mm, suitable for through-wiring Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
Ceiling (recessed)
HE H
DA D
Ø218
Ø200
Article number
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
671857.96X.Y
Ceiling (recessed)
1/1
15 %
671859.96X.Y
Ceiling (recessed)
2/1
671858.95X.Y
Ceiling (recessed)
671860.95X.Y
Ceiling (recessed)
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
1 x TC-DEL 18 W
•
•
-
3h
D 218, H 3 DA 200, HE 106
15 %
2 x TC-DEL 18 W
•
•
-
3h
D 218, H 3 DA 200, HE 106
1/1
12 %
1 x TC-DEL 26 W
•
•
-
3h
D 218, H 3 DA 200, HE 106
2/1
12 %
2 x TC-DEL 26 W
•
•
-
3h
D 218, H 3 DA 200, HE 106
Cover screens with spring fastening IP 43 981734.000 Safety glass, transparent
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671857.96X und 671859.96X
Spacing table 671858.95X und 671860.95X
Lamp luminous flux:
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
Mains: 1800 lm, Emergency: 216 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
7.6
3.3
8.3
3.5
2.5
7.5
3.0
8.1
3.3
3.0
8.5
3.4
9.2
3.8
3.0
8.2
2.8
8.9
3.3
3.5
9.4
3.1 10.0
3.8
3.5
8.5
2.5
9.4
2.5
4.0
9.5
3.0 10.7
3.0
4.0
8.1
2.2
9.0
2.6
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
85
emergency Lighting | self-contained emergency luminaires Mondana Type of protection: IP 65 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Diffuser: glass or PE sintered glass (polyethylene), shockproof - IP 65 provides safe protection against humidity - dust and insects cannot penetrate the luminaire - Gore™ diaphragm valve for pressure equalisation and prevention of condensation - Easy to install - Wide range of applications thanks to various types of installation - Lamp replacement without tools
Surface installation (wall, ceiling) D 500 and D 550
86
Semi-recessed installation (wall, ceiling)
DA 390
Recessed installation (wall and ceiling)
DA 625
emergency Lighting | self-contained emergency luminaires Series: Mondana Type of protection: IP 65 for indoor use Protection class: I Ceiling thickness: 10-30 mm For escape route illumination Base: plastic (polycarbonate), microstructure coating; diffuser: plastic (polyethylene) or mouth-blown opal glass, satin finish. Diffuser fastening: screwneck; housing for semi-recessed installation in walls and ceilings: powder-coated aluminium. Standard Gore™ Protective Vents diaphragm valve for reduction of condensation. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
Surface installation (wall, ceiling) D 500 and D 550
Semi-recessed installation (wall, ceiling) D
DA 390
Recessed installation (wall and ceiling)
H
DA 625
H
D
H
D
DA
DA
HE
HE
Ø380
140
65
Ø390
70
Ø625
Ø5,5
5 242,5
Article number
Type of installation
Type
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671777.86X.Y
Wall (surface), Ceiling (surface)
Glass
14 %
1 x TC-F 36 W
•
•
-
3h
D 500, H 128
671778.86X.Y
Wall (surface), Ceiling (surface)
PE
14 %
1 x TC-F 36 W
•
•
-
3h
D 550, H 135
671803.86X.Y
Semi-recessed instal‑ lation (wall, ceiling)
Glass
14 %
1 x TC-F 36 W
•
•
-
3h
D 500, H 78 DA 390, HE 100
671802.86X.Y
Semi-recessed instal‑ lation (wall, ceiling)
PE
14 %
1 x TC-F 36 W
•
•
-
3h
D 550, H 85 DA 390, HE 100
671779.86X.Y
Wall (recessed), Ceiling (recessed)
PE
14 %
1 x TC-F 36 W
•
•
-
3h
D 650, H 2 DA 625, HE 140
Accessories | Moulded housing Moulded housing 981631.002 981631.002
for Mondana D 500 for Mondana D 550
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671803.00X
Spacing table 671802.00X
Lamp luminous flux:
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
6.6
2.4
6.6
2.4
2.5
5.8
2.7
5.6
2.7
3.0
6.8
2.3
6.8
2.3
3.0
7.6
2.8
7.6
2.8
3.5
6.9
2.1
6.9
2.1
3.5
7.9
2.7
7.9
2.7
4.0
6.8
1.9
6.8
1.9
4.0
8.0
2.6
8.0
2.6
Spacing table 671777.86X
Spacing table 671778.00X
Spacing table 671779.86X
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
Mains: 2800 lm, Emergency: 392 lm
Mains: 2800 lm, Emergency: 392 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
h
a
b
c
d
2.5
6.6
2.4
6.6
2.4
2.5
5.8
2.7
5.6
2.7
2.5
6.1
2.8
6.0
2.8
3.0
6.8
2.3
6.8
2.3
3.0
7.6
2.8
7.6
2.8
3.0
6.3
3.0
6.1
3.0
3.5
6.9
2.1
6.9
2.1
3.5
7.9
2.7
7.9
2.7
3.5
8.3
2.9
8.3
2.9
4.0
6.8
1.9
6.8
1.9
4.0
8.0
2.6
8.0
2.6
4.0
8.5
2.8
8.5
2.8
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
87
emergency Lighting | self-contained emergency luminaires Flat Polymero速 Type of protection: IP 40 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Compact design - Extremely high Light Output Ratio of up to 81% - Easy to install - Low maintenance costs - Wide range of applications thanks to various types of installation
Ceiling (surface), Wall (surface)
88
8h
for accomodation facilities, nursing homes and multi-storey buildings (only in Germany)
emergency Lighting | self-contained emergency luminaires Series: Flat Polymero® Type of protection: IP 40 Protection class: I For escape route illumination Base: metal, powder-coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: patented push lock. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface) D 460
Ceiling (surface), Wall (surface) D 515
Ceiling (surface), Wall (surface) D 620
D
D
D
H
H
H
Ø460
Ø620
Ø5
Ø5
142
Installation scheme available on request
78
71
23
246
Article number
325
30
325
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
Lamp/Wattage
26
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671587.96X.1.Y
Ceiling (surface), Wall (surface)
2/1
15 %
2 x TC-DEL 18 W
•
•
-
3h
D 460, H 120
671700.34X.1.Y
Ceiling (surface), Wall (surface)
2/1
15 %
1 x TC-TEL 18 W + 2 x TC-TSE 18 W
•
•
-
3h
D 460, H 120
671531.95X.1.Y
Ceiling (surface), Wall (surface)
2/1
15 %
1 x TC-DEL 26 W + 1 x TC-DEL 26 W
•
•
-
3h
D 515, H 150
671585.86X.1.Y
Ceiling (surface), Wall (surface)
2/1
15 %
2 x TC-F 36 W
•
•
-
3h
D 620, H 155
671911.95X.1.Y
Ceiling (surface), Wall (surface)
2/1
15 %
2 x TC-DEL 26 W
•
•
-
8h
D 620, H 160
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671911.95X
Spacing table 671700.34X
Lamp luminous flux:
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
The following values are indicated in m
h
a
2.5
13.0
3.0 3.5 4.0
b
c
d
h
a
5.2 13.0
5.2
2.5
10.8
4.6 10.8
b
c
4.6
d
13.1
5.6 13.1
5.6
3.0
12.1
4.8 12.1
4.8
14.3
5.8 14.3
5.8
3.5
12.8
5.0 12.8
5.0
15.1
6.1 15.1
6.1
4.0
12.8
5.2 12.8
5.2
Spacing table 671531.95X.1
Spacing table 671585.862
Spacing table 671587.962
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
Mains: 2800 lm, Emergency: 392 lm
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
b
c
d
h
a
b
c
d
2.5
13.0
5.2 13.0
5.2
2.5
7.6
3.2
7.6
3.2
2.5
5.7
2.2
5.7
2.2
b
c
3.0
13.1
5.6 13.1
5.6
3.0
8.4
3.4
8.4
3.4
3.0
5.9
2.2
5.9
2.2
3.5
14.3
5.8 14.3
5.8
3.5
8.8
3.4
8.8
3.4
3.5
6.1
2.0
6.1
2.0
4.0
15.1
6.1 15.1
6.1
4.0
8.9
3.4
8.9
3.4
4.0
6.2
1.6
6.2
1.6
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
89
emergency Lighting | self-contained emergency luminaires Flat Polymero速 PC with collar Type of protection: IP 20 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Architecturally attractive design - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the diffuser
Ceiling (surface), Wall (surface)
90
emergency Lighting | self-contained emergency luminaires Series: Flat Polymero® PC with collar Type of protection: IP 20 Protection class: I For escape route illumination Base: plastic, white, with collar: perforated metal, powder-coated. Diffuser: plastic (polycarbonate), opal. Diffuser fastening: spring system. Ballast mains/emergency: EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface)
Ceiling (surface), Wall (surface)
D
D
Ø
Ø H
H
5
25
384,5 335
3x120°
3x120°
90
50
Ø6 220 266
Article number
5,5
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671495.96X.Y
Ceiling (surface), Wall (surface)
1/1
15 %
1 x TC-DEL 18 W
•
•
-
3h
D 310, H 190, Ø 265
671496.95X.Y
Ceiling (surface), Wall (surface)
1/1
12 %
1 x TC-DEL 26 W
•
•
-
3h
D 310, H 190, Ø 265
671498.86X.Y
Ceiling (surface), Wall (surface)
2/1
15 %
2 x TC-F 36 W
•
•
-
3h
D 420, H 205, Ø 385
671497.98X.Y
Ceiling (surface), Wall (surface)
2/1
18 %
2 x TC-L 18 W
•
•
-
3h
D 420, H 205, Ø 385
Collar for general lighting height adjustment: see our latest product selection guide.
Spacing table 671498.862 / 36 W
Lamp luminous flux: Mains: 2800 lm, Emergency: 392 lm The following values are indicated in m
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
h
a
b
c
d
2.5
7.6
3.1
7.6
3.1
3.0
8.3
3.2
8.3
3.2
3.5
8.2
3.2
8.2
3.2
4.0
8.3
3.1
8.3
3.1
Spacing table 671495.962
Spacing table 671496.962
Spacing table 671497.982
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 1200 lm, Emergency: 180 lm
Mains: 1800 lm, Emergency: 216 lm
Mains: 1200 lm, Emergency: 216 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
h
a
b
c
d
2.5
5.2
2.0
5.2
2.0
2.5
5.7
2.2
5.7
2.2
2.5
5.9
2.3
5.9
2.3
3.0
5.8
1.9
5.8
1.9
3.0
5.9
2.2
5.9
2.2
3.0
6.1
2.3
6.1
2.3
3.5
4.9
1.6
4.9
1.6
3.5
5.6
2.0
5.6
2.0
3.5
5.7
2.1
5.7
2.1
4.0
4.8
1.1
4.8
1.1
4.0
5.6
1.7
5.6
1.7
4.0
5.9
1.8
5.9
1.8
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
91
emergency Lighting | self-contained emergency luminaires Flat Basic Type of protection: IP 43 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Architecturally attractive design - Low maintenance costs - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
Ceiling (surface), Wall (surface)
92
emergency Lighting | self-contained emergency luminaires Series: Flat Basic Type of protection: IP 43 Protection class: I For escape route illumination Base: die-cast aluminium, powder-coated. Opal glass: mouth-blown, satin finish. Glass fastening: springs. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: LLB/EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface)
D
Ø H
400
258
95
214
5x8
50
Article number
Type of installation Ceiling (surface), Wall (surface)
671423.91X.Y
Planning guide: Escape route illumination in accordance with EN 1838
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
2/1
30 %
2 x TC-EL 9 W
•
•
-
Rated operat‑ Dimensions ing time 3h
D 420, H 124
Spacing table 671423.912
Lamp luminous flux:
a b
Lamps Mains/ Emergency
c
d
h
E = 1 lx along the centre line
Mains: 600 lm, Emergency: 180 lm The following values are indicated in m h
a
b
c
d
2.5
6.9
2.6
6.9
2.6
3.0
7.0
2.6
7.0
2.6
3.5
7.2
2.5
7.2
2.5
4.0
6.8
2.3
6.8
2.3
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
93
emergency Lighting | self-contained emergency luminaires Flat Basic with collar Type of protection: IP 20 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Architecturally attractive design - Low maintenance costs - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
Ceiling (surface), Wall (surface)
94
emergency Lighting | self-contained emergency luminaires Series: Flat Basic with collar Type of protection: IP 20 Protection class: I For escape route illumination Especially for use with movement sensors and automatic staircase switches. Base: plastic with perforated metal collar, powder-coated. Opal glass: mouth-blown, satin finish. Glass fastening: springs. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface)
Ceiling (surface), Wall (surface)
D
D
Ø
Ø H
H
5
25
384,5 335
3x120°
3x120°
90
50
Ø6 220 266
Article number
5,5
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671521.00X.Y
Ceiling (surface), Wall (surface)
2/1
12 %
2 x E27 25 W + 1 x TC-DEL 26 W
•
•
-
3h
D 420, H 200, Ø 265
671455.96X.Y
Ceiling (surface), Wall (surface)
2/1
15 %
2 x TC-DEL 18 W
•
•
-
3h
D 420, H 200, Ø 265
671456.95X.Y
Ceiling (surface), Wall (surface)
2/1
12 %
2 x TC-DEL 26 W
•
•
-
3h
D 420, H 200, Ø 265
671493.98X.Y
Ceiling (surface), Wall (surface)
2/1
18 %
2 x TC-L 18 W
•
•
-
3h
D 500, H 205, Ø 385
671494.86X.Y
Ceiling (surface), Wall (surface)
2/1
15 %
2 x TC-F 36 W
•
•
-
3h
D 500, H 205, Ø 385
Collar for general lighting height adjustment: see our latest product selection guide.
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671494.862
Spacing table 671493.982
Lamp luminous flux:
Lamp luminous flux:
Mains: 2800 lm, Emergency: 392 lm
Mains: 1200 lm, Emergency: 180 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
7.6
3.2
7.6
3.2
2.5
6.9
2.6
6.9
2.6
3.0
8.4
3.4
8.4
3.4
3.0
7.0
2.6
7.0
2.6
3.5
8.8
3.4
8.8
3.4
3.5
7.2
2.5
7.2
2.5
4.0
8.9
3.4
8.9
3.4
4.0
6.8
2.3
6.8
2.3
Spacing table 671521.002
Spacing table 671455.962
Spacing table 671456.952
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 1800 lm, Emergency: 216 lm
Mains: 1200 lm, Emergency: 180 lm
Mains: 1800 lm, Emergency: 220 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
h
a
b
c
d
2.5
6.9
2.7
6.9
2.7
2.5
6.9
2.6
6.9
2.6
2.5
7.2
2.9
7.2
2.9
3.0
6.9
2.7
6.9
2.7
3.0
7.0
2.6
7.0
2.6
3.0
7.8
2.9
7.8
2.9
3.5
7.1
2.6
7.1
2.6
3.5
7.2
2.5
7.2
2.5
3.5
7.5
2.9
7.5
2.9
4.0
6.6
2.4
6.6
2.4
4.0
6.8
2.3
6.8
2.3
4.0
8.2
2.8
8.2
2.8
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
95
emergency Lighting | self-contained emergency luminaires Flat Polymero速 Rechteck Type of protection: IP 40 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Very large viewing distance with motifs - Flat design - Luminaire can be opened without tools
Wall (surface)
96
Ceiling (surface), Wall (surface)
emergency Lighting | self-contained emergency luminaires Series: Flat Polymero® Rechteck Type of protection: IP 40 Protection class: I Viewing distance: 50 m For escape route identification (only in case of wall installation) or escape route illumination Base: metal, powder-coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: sash lock, plastic. Please quote symbol number when ordering escape route motifs! Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Mains operation: more than 1lamp Emergency mode: 1 lamp
50 m
When used as escape route luminaire, please note luminous flux factors. Available colour (X): 2 = white
Wall (surface), Ceiling (surface)
H
B
L
600 530
Ø5,5
320 245
48 306
581
Article number
Type of installation Wall (surface), Ceiling (surface) Wall (surface), Ceiling (surface)
671718.75X.Y 671719.75X.Y
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Viewing distance
Luminous flux factor
50 m
32 %
50 m
19 %
Lamp/Wattage
PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
2 x T16 (T5) 14 W
•
•
-
3h
L 600, B 320, H 75
2 x T16 (T5) 24 W
•
•
-
3h
L 600, B 320, H 75
Spacing table 671718.752
Spacing table 671719.752
Lamp luminous flux:
Lamp luminous flux:
Mains: 2400 lm, Emergency: 384 lm
Mains: 3500 lm, Emergency: 332 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
2.5
8.3
3.1 8.3 3.1
2.5
7.7 2.9 7.7 2.9
3.0
8.7 3.2 8.7 3.2
3.0
8.0 2.9 8.0 2.9
3.5
9.0 3.1 9.0 3.1
3.5
8.3 2.8 8.3 2.8
4.0
9.1 3.0 9.1 3.0
4.0
8.3 2.6 8.3 2.6
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
b
c
Rated operat‑ Dimensions ing time
d
97
emergency Lighting | self-contained emergency luminaires Basic Type of protection: IP 43 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Architecturally attractive design - Low maintenance costs - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
Ceiling (surface), Wall (surface)
98
emergency Lighting | self-contained emergency luminaires Series: Basic Type of protection: IP 43 Protection class: I For escape route illumination Base: die-cast aluminium, powder-coated. Opal glass: mouth-blown, satin finish. Glass fastening: springs. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: LLB/EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface)
D
Ø H
280
258
95
214
5x8
50
Article number
Type of installation
Lamps Mains/ Emergency
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671112.92X.Y
Ceiling (surface), Wall (surface)
1/1
14 %
1 x TC-DEL 13 W
•
•
-
3h
D 280, H 145
671095.91X.Y
Ceiling (surface), Wall (surface)
1/1
30 %
1 x TC-EL 9 W
•
•
-
3h
D 280, H 145
671422.91X.Y
Ceiling (surface), Wall (surface)
2/1
30 %
2 x TC-EL 9 W
•
•
-
3h
D 280, H 145
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671112.922
Spacing table 671095.912
Spacing table 671422.912
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 900 lm, Emergency: 126 lm
Mains: 600 lm, Emergency: 180 lm
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
h
a
b
c
d
2.5
4.8
1.4
4.8
1.4
2.5
5.8
1.9
5.8
1.9
2.5
5.8
1.9
5.8
1.9
3.0
4.6
0.9
4.6
0.9
3.0
5.6
1.7
5.6
1.7
3.0
5.6
1.7
5.6
1.7
3.5 - - - -
3.5
5.4
1.2
5.4
1.2
3.5
5.4
1.2
5.4
1.2
4.0 - - - -
4.0 - - - -
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
4.0 - - - -
99
emergency Lighting | self-contained emergency luminaires Kreis Type of protection: IP 43 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Low maintenance costs - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
Ceiling (surface), Wall (surface)
100
emergency Lighting | self-contained emergency luminaires Series: Kreis Type of protection: IP 43 Protection class: I For escape route illumination Base: die-cast aluminium, powder-coated. Opal glass: mouth-blown, satin finish. Glass fastening: springs. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: LLB/EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface)
D
H
280
258
95
214
5x8
50
Article number
Type of installation Ceiling (surface), Wall (surface)
671425.91X.Y
Planning guide: Escape route illumination in accordance with EN 1838
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
2/1
30 %
2 x TC-EL 9 W
•
•
-
Rated operat‑ Dimensions ing time 3h
D 280, H 120
Spacing table 671425.912
Lamp luminous flux:
a b
Lamps Mains/ Emergency
c
d
h
E = 1 lx along the centre line
Mains: 600 lm, Emergency: 180 lm The following values are indicated in m h
a
b
c
d
2.5
5.8
1.9
5.8
1.9
3.0
5.6
1.7
5.6
1.7
3.5
5.4
1.2
5.4
1.2
4.0 - - - -
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
101
emergency Lighting | self-contained emergency luminaires Rondo Type of protection: IP 43 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Low maintenance costs - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass
Ceiling (surface), Wall (surface)
102
emergency Lighting | self-contained emergency luminaires Series: Rondo Type of protection: IP 43 Protection class: I For escape route illumination Base: die-cast aluminium, powder-coated. Opal glass: mouth-blown, satin finish. Glass fastening: springs. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: LLB/EB Available colour (X): 2 = white
Ceiling (surface), Wall (surface)
D
Ø H
400
258
95
214
5x8
50
Article number
Type of installation Ceiling (surface), Wall (surface)
671427.91X.Y
Planning guide: Escape route illumination in accordance with EN 1838
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
2/1
30 %
2 x TC-EL 9 W
•
•
-
Rated operat‑ Dimensions ing time 3h
D 400, H 125
Spacing table 671427.912
Lamp luminous flux:
a b
Lamps Mains/ Emergency
c
d
h
E = 1 lx along the centre line
Mains: 600 lm, Emergency: 180 lm The following values are indicated in m h
a
b
c
d
2.5
6.6
2.3
6.6
2.3
3.0
6.6
2.1
6.6
2.1
3.5
6.4
1.8
6.4
1.8
4.0
6.2
1.1
6.2
1.1
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
103
emergency Lighting | self-contained emergency luminaires Rounded Maxi Type of protection: IP 55 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Housing made of top quality die-cast aluminium - Low maintenance costs - Compact design - Easy to install - IP 55 type of protection - dustproof and protected against water jets
Ceiling (surface), Wall (surface)
104
emergency Lighting | self-contained emergency luminaires Series: Rounded Maxi Type of protection: IP 55 for indoor use Protection class: I For escape route illumination Mounting support and cover ring: powder-coated aluminium; diffuser: opal glass, silk finish. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast emergency/mains: EB Available colours (X): 2 = white, 31 = anthracite metallic, 4 = silver metallic
Ceiling (surface), Wall (surface)
D
H
Ø400
280
260
Ø5
120 Ø380
Article number
Type of installation Ceiling (surface), Wall (surface)
671735.92X.Y
Planning guide: Escape route illumination in accordance with EN 1838
Luminous flux factor
2/1
14 %
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
•
•
-
2 x TC-DEL 13 W
Rated operat‑ Dimensions ing time 3h
D 400, H 130
Spacing table 671735.92X
Lamp luminous flux:
a b
Lamps Mains/ Emergency
c
d
h
E = 1 lx along the centre line
Mains: 3600 lm, Emergency: 216 lm The following values are indicated in m h
a
b
c
d
2.5
6.5
2.1
5.7
1.9
3.0
6.6
2.0
5.8
1.7
3.5
6.5
1.5
5.7
1.3
4.0
6.1
0.2
5.3
0.4
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
105
emergency Lighting | self-contained emergency luminaires Alu窶然und Type of protection: IP 54 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Housing made of sturdy die-cast aluminium - Low maintenance costs - Compact design - Easy to install - With glass cover
Ceiling (surface), Wall (surface)
106
Ceiling (surface), Wall (surface)
emergency Lighting | self-contained emergency luminaires Series: Alu‑Rund Type of protection: IP 54 for indoor use Protection class: I For escape route illumination Base: die-cast aluminium, powder-coated. Opal glass. Guard: die-cast aluminium, powder-coated. Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colours (X): 2 = white, 3 = black
Ceiling (surface), Wall (surface)
Ceiling (surface), Wall (surface)
D
D
H
45
240
45
65
240
62
42 74 60
Article number
H
65
Ø6
Type of installation
62
42 74 60
Type
Ø6
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671107.91X.Y
Ceiling (surface), Wall (surface)
without guard
30 %
1 x TC-EL 9 W
•
•
-
3h
D 240, H 130
671109.91X.Y
Ceiling (surface), Wall (surface)
with guard
30 %
1 x TC-EL 9 W
•
•
-
3h
D 240, H 130
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671107.91X
Spacing table 671109.91X
Lamp luminous flux:
Lamp luminous flux:
Mains: 600 lm, Emergency: 180 lm
Mains: 600 lm, Emergency: 180 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
6.7
2.5
6.7
2.5
2.5
6.7
2.5
6.7
2.5
3.0
6.9
2.3
6.9
2.3
3.0
6.9
2.3
6.9
2.3
3.5
7.1
1.9
7.1
1.9
3.5
7.1
1.9
7.1
1.9
4.0
6.3
1.4
6.3
1.4
4.0
6.3
1.4
6.3
1.4
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
107
emergency Lighting | self-contained emergency luminaires Weatherproof battens Type of protection: IP 65 - IP 65 type of protection - dustproof and protected against water jets from all directions - Industrial design - Lamp replacement without tools
Ceiling (surface), Wall (surface)
108
emergency Lighting | self-contained emergency luminaires Series: Weatherproof battens Type of protection: IP 65 for indoor use Protection class: I For escape route illumination Base: plastic, grey. Lamp: open beam Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colour (X): 9 = grey
Ceiling (surface), Wall (surface) 36 W
Ceiling (surface), Wall (surface) 58 W
H L
H
B
L
B
1258
1558
62
62 Ø10
Article number
Ø10
740
Type of installation
Viewing distance
Luminous flux factor
Lamp/Wattage
1050
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operat‑ Dimensions ing time
671093.75X.Y
Ceiling (surface), Wall (surface)
-
13 %
1 x T26 (T8) 36 W
•
•
-
3h
L 1258, B 62, H 122
671446.75X.Y
Ceiling (surface), Wall (surface)
-
8%
1 x T26 (T8) 58 W
•
•
-
3h
L 1558, B 62, H 122
Accessories | Protective tubes for weatherproof battens Replacement diffuser, plastic transparent 981441.000 L 1170, D 38 981442.000 L 1470, D 38
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
for T26 36 W for T26 58 W
Spacing table 671093.759
Spacing table 671446.759
Lamp luminous flux:
Lamp luminous flux:
Mains: 3350 lm, Emergency: 436 lm
Mains: 5200 lm, Emergency: 432 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
2.5
8.2
c
d
h
a
b
3.3 11.7
4.5
2.5
8.1
3.2 11.6
c
4.5
d
3.0
8.4
3.4 11.7
4.6
3.0
8.4
3.4 11.6
4.6
3.5
9.0
3.5 12.1
4.7
3.5
9.0
3.5 12.1
4.7
4.0
9.5
3.5 12.0
4.7
4.0
9.5
3.5 12.0
4.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
109
emergency Lighting | self-contained emergency luminaires Hand‑held LED safety spotlight Type of protection: IP 54
Safety stand spotlight Type of protection: IP 54
- LED technology
- IP 54 type of protection - dustproof and protected against water spray
- Charging level display - Shockproof plastic housing - Universal mounting adaptor included
Hand-held LED safety spotlight
110
- Functional design - Robust materials - For high rooms
Safety stand spotlight
emergency Lighting | self-contained emergency luminaires Series: Hand‑held LED safety spotlight
Series: Safety stand spotlight Type of protection: IP 54 Protection class: I
Type of protection: IP 54 Protection class: II in charging mode; Protection class: III in battery mode
Luminaire housing: metal, grey, powder-coated. Luminaire tops: swivelling. Safety glass: transparent. Lamps included.
Luminaire housing: plastic, grey. Ergonomically designed onehand handle, black. Front frame: plastic, red. Cover: polycarbonate, transparent, with four-coloured light scatter disk attachment. Universal mounting adaptor: metal, painted. Integrated charger: 230 V at 50/60 Hz. Automatic changeover from quick to trickle charging.Preselec‑ tion between static and flashing light mode possible. Operation of the LED lamp at 100% or 10% performance. Maintenance-free NiCd rechargeable battery 6 V / 4.0 Ah, charge status indicator.
Operating mode: Non-maintained (BS), maintenance-free Pb storage batteries.
Charge in dry rooms only! Operating time in static mode: LED lamp 100% > 4 h, LED lamp 10% > 13.5h Available colour (X): 9 = grey
Hand-held LED safety spotlight
L
Safety stand spotlight
H
180 H B
L
B
Hand-held LED safety spotlight Article number
Type of installation
671824.00X.Y
-
Viewing distance
Luminous flux factor
-
-
Viewing distance
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
-
-
-
PZ 50 (.03)
Multi‑Digit (.04)
DALI (.07)
1 x LED 3,35 W
Rated operat‑ Dimensions ing time 4h
L 160, B 155, H 285
Safety stand spotlight Article number
Type of installation
Lamp/Wattage
Rated operat‑ Dimensions ing time
65940
-
-
-
2 x QT-H3 55 W
-
-
-
1h
L 500, B 165, H 500
65942
-
-
-
2 x QT-H3 55 W
-
-
-
3h
L 500, B 165, H 500
65936
-
-
-
2 x QT9 (axial) 20 W
-
-
-
1h
L 318, B 160, H 410
65938
-
-
-
2 x QT9 (axial) 20 W
-
-
-
3h
L 500, B 165, H 500
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
111
KVG/VVG
zur Allgemeinbeleuchtung
Mit 1 Lampe
ST/AB-Bus
ter
LE L‘ N L PE
E
+ rot schwarz
6 5 4 3 2 1
S
FL
NiCd-Akku (NiMH)
KVG/VVG
zur gemeinbeeuchtung
ST/AB-Bus
er
LE L‘ N L PE
NiCd-Akku (NiMH)
112
E
+ rot schwarz
6 5 4 3 2 1
S
FL FL S
Mit 2 Lampen
Self-contained emergency conversion kits Emergency conversion kits
114 - 116
Power supply units
116 - 117
Emergency power supply units Connecting diagrams
118 119 - 121
113
emergency Lighting | Self-Contained conversion kits
Emergency conversion kits Emergency lighting fitment Power supply units Conversion kits System benefits - High luminous flux factor reduces number of required luminaires - Large LED display (5 mm) - Constant light current control - Complete series (standard, self-test, MultiDigitÂŽ) - Universally suited for LLB/EB, irrespective of manufacturer
Connecting diagramms: see pages 119 - 120
- Conversion kits for DALI available (upon request)
Universal installation kit for luminaires of general purpose lighting
230 V / 50 Hz
230 V / 50 Hz
Sub distribution board General purpose lighting
Ideally suited for converting general purpose lighting luminaires into selfcontained emergency luminaires.
S G
Type of protection: IP 20 Protection class: I Electronic module housing: metal, galvanised. Charging indicator lamp (LED): standard. NiCd high-temperature rechargeable battery and instructions for retrofitting this module into existing luminaires are included.
L'
The modules conform to VDE0108 and EN60598, part 2-22.
N PE
Self-contained luminaire, non-maintained (BS)
After conversion the luminaire can be operated in maintained or nonmaintained power mode.
General purpose lighting
This module can be used together with the low-lost ballast (4-pin lamp holder, external starter required) or EB of the luminaire. The ballast in the luminaire controls operation of the lamp(s) when mains power is applied. Should the mains power supply fail, one lamp is automatically powered by the battery via the 230 emergency conversion kit. V / 50 Hz
L
General pu
230 V / 50 Hz
Sub distribution board General purpose lighting
L'
L
N PE
Sub distribution board General purpose lighting
L'
L
N PE
Please note: Constant phase = charging phase, must always be connected to L.
Self-contained luminaire, non-maintained (BS)
Self-contained luminaire, maintained (DS)
L’ and L must use the same phase. The circuit must be potential-free.
114
General purpose lighting
General purpose lighting
emergency Lighting | Self-Contained conversion kits
Standard emergency conversion kits 6 – 80 W (battery included) Nom. operating time 1h
Emergency conversion kits with high luminous flux factor 14 – 80 W (battery included)
Nom. operating time 3h
Nom. operating time 1h Nom. operating time 3h
Standard module Catalogue number:
Standard module 09-6284.000
Catalogue number:
09-6287.000
Self-test module (version .03) Catalogue number:
Lamp/Wattage T16 6W T16 8W T16 13 W T16 14 W T16 21 W T16 24 W T16 28 W T16 35 W T16 39 W T16 49 W T16 54 W T16 80 W T26 10 W T26 15 W T26 16 W T26 18 W T26 30 W T26 36 W T26 58 W TC-L 18 W TC-L 24 W TC-L 36 W TC-L 40 W TC-L 55 W TC-EL 5 W TC-EL 7 W TC-EL 9 W TC-EL 11 W TC-DEL 10 W TC-DEL 13 W TC-DEL 18 W TC-DEL 26 W TC-TEL 18 W TC-TEL 26 W TC-TEL 32 W TC-TEL 42 W T16-R 22 W T16-R 40 W T16-R 55 W T16-R 60 W T29-R 22 W T32-R 32 W T32-R 40 W Module dimensions Battery Battery dimensions Spare battery Spare battery
09-6293.000
09-6291.000
09-6294.000
09-6292.000
09-6295.000
Self-test module (version .03) 09-6285.000
Catalogue number:
09-6288.000
MultiDigit® module (version .04) Catalogue number:
09-6290.000
MultiDigit® module (version .04) 09-6286.000
Catalogue number:
09-6289.000
Luminous flux factor mains/emergency in % 50 % 37 % 23 % 21 % 14 % 12 % 10 % 8% 7% 6% 5% 3% 30 % 20 % 18 % 16 % 10 % 8% 5% 16 % 12 % 8% 7% 5% 50 % 42 % 33 % 27 % 30 % 23 % 16 % 11 % 16 % 11 % 9% 13 % 7% 5% 5% 13 % 9% 7%
Lamp/Wattage
50 % 37 % 23 % 21 % 14 % 12 % 10 % 8% 7% 6% 5% 3% 30 % 20 % 18 % 16 % 10 % 8% 5% 16 % 12 % 8% 7% 5% 50 % 42 % 33 % 27 % 30 % 23 % 16 % 11 % 16 % 11 % 9% 13 % 7% 5% 5% 13 % 9% 7%
180 x 40 x 28 4,8 V/1,8 Ah D 24, L 2 x 88
180 x 40 x 28 4,8 V/4,5 Ah D 33, L 242
67000.0.61
67000.0.62
T16 6W T16 8W T16 13 W T16 14 W T16 21 W T16 24 W T16 28 W T16 35 W T16 39 W T16 49 W T16 54 W T16 80 W T26 10 W T26 15 W T26 16 W T26 18 W T26 30 W T26 36 W T26 58 W TC-L 18 W TC-L 24 W TC-L 36 W TC-L 40 W TC-L 55 W TC-EL 5 W TC-EL 7 W TC-EL 9 W TC-EL 11 W TC-DEL 10 W TC-DEL 13 W TC-DEL 18 W TC-DEL 26 W TC-TEL 18 W TC-TEL 26 W TC-TEL 32 W TC-TEL 42 W T16-R 22 W T16-R 40 W T16-R 55 W T16-R 60 W T29-R 22 W T32-R 32 W T32-R 40 W Module dimensions Battery Battery dimensions Spare battery Spare battery
Luminous flux factor mains/emergency in % 49 % 32 % 28 % 24 % 19 % 17 % 14 % 12 % 8% 69 % 46 % 43 % 38 % 23 % 19 % 11 % 38 % 28 % 19 % 17 % 12 % 38 % 26 % 38 % 26 % 21 % 16 % 31 % 17 % 12 % 11 % 31 % 21 % 17 %
32 % 21 % 18 % 16 % 12 % 11 % 9% 8% 5% 45 % 30 % 28 % 25 % 15 % 12 % 7% 25 % 18 % 12 % 11 % 8% 25 % 17 % 25 % 17 % 14 % 10 % 20 % 11 % 8% 7% 20 % 14 % 11 %
180 x 40 x 28 4,8 V/4,5 Ah D 33, L 242
180 x 40 x 28 7,2 V/4,5 Ah D 33, L 2 x 182
67000.0.62
67000.0.63* * 2 batteries required
The above indicated luminous flux factors are recommended hypothetical values for ambient temperatures of 25° C. Inasmuch as colour rendering and luminous flux in emergency mode are mainly determined by lamp temperature and/or luminaire design and construction, light should be measured at lower temperatures for each type of luminaire. Any lamp manufactured with amalgam technology, such as the Philips PL-T TOP, shall be excluded and shall be subject to prior testing. Only quality products from reputable vendors are to be used. The values in the table above are intended as recommendations only and are subject to change. All applications shall be subject to prior testing. We reserve the right to effect changes in the table above without prior notice. T16/T5 tubes have a so-called “cold spot” at the tip of the tube, usually positioned at that tube tip which bears the lettering. For improved emergency mode, this cold spot or tube tip should be connected to outputs 6 and 8 of the lamp terminal. The luminaire should be marked in such a way as to ensure that the tube is inserted in the right direction.
Tender texts available upon request | Specifications subject to alteration
115
emergency Lighting | Self-Contained conversion kits
Emergency conversion kits Power supply units Ideally suited for converting general purpose lighting luminaires into self-contained safety luminaires Type of protection: IP 30 Protection class: I Housing: metal, powder-coated. NiCd rechargeable battery included. The low-loss ballast (4-pin lamp holder, external starter required) or the EB of the luminaire to be converted powers the lamp in mains mode. The emergency light module automatically powers the lamp in emergency mode. Switching mode: either maintained mode or non-maintained mode. Luminaire equipment, power supply units: charging indicator (LED), standard. Maintenance-free NiCd rechargeable batteries. Nominal operating time: 1 or 3 hours. Max. length of cable between emergency supply unit and lamp: LLB = 2 m, EB = 0.5 m. Permissible ambient temperature: 0 -40째 C. Luminous flux factors, see previous page. Available colours: 2 = white, 3 = black Emergency conversion kit for fluorescent lamps in recessed or surface mounted housing L 390, B 100, H 55 981158.003 1h 28 W 981158.003.03 1h 28 W 981158.003.04 1h 28 W 981159.003 3h 28 W 981159.003.03 3h 28 W 981159.003.04 3h 28 W 981160.003 1h 65 W 981160.003.03 1h 65 W 981160.003.04 1h 65 W 981161.003 3h 65 W 981161.003.03 3h 65 W 981161.003.04 3h 65 W
2.3 kg 2.3 kg 2.3 kg 2.3 kg 2.3 kg 2.3 kg 2.3 kg 2.3 kg 2.3 kg 2.5 kg 2.5 kg 2.5 kg
H B
L
Emergency conversion kit for fluorescent lamps in surface mounted housing, with luminaire suspension eyelet L 340, B 170, H 75 981162.002 1h 28 W 1.7 kg 981162.002.03 1h 28 W 1.7 kg 981162.002.04 1h 28 W 1.7 kg 981163.002 3h 28 W 1.7 kg 981163.002.03 3h 28 W 1.7 kg 981163.002.04 3h 28 W 1.7 kg 981164.002 1h 65 W 1.7 kg 981164.002.03 1h 65 W 1.7 kg 981164.002.04 1h 65 W 1.7 kg 981165.002 3h 65 W 1.9 kg 981165.002.03 3h 65 W 1.9 kg 981165.002.04 3h 65 W 1.9 kg
H
B
L
116
Tender texts available upon request | Specifications subject to alteration
emergency Lighting | Self-Contained conversion kits
NCH complete conversion kit Ideally suited for converting general purpose lighting luminaires into self-contained emergency luminaires. for low-voltage halogen lamps of up to 50 W, voltage: 6 V. Nominal operating time: 1 or 3 hours. Housing: L 183, B 40, H 32 Rechargeable battery 6 V/4,0 Ah: L 312, B 40, H 32. L
H B
B L
H
09-6019.000
QT max. 50 W 2 h/100 %
6 V 10 W
1 h/100 %
6 V 20 W
5 h/ 10 %
12 V 10 W
2 h/ 10 %
12 V 20 W
1 h/ 10 %
12 V 35 W
1 h/ 10 %
12 V 50 W
NCH safety conversion kit Ideally suited for converting general purpose lighting luminaires into self-contained safety luminaires
H B
Nominal operating time: 1 or 3 hours. Max. length of cable between emergency supply unit and lamp: 1m. Luminous flux factors, see table on page 115. Safety conversion kits for low-voltage halogen lamps in recessed or surface mounted housing (black module) 981127.003
L
L 390, B 100, H 55
in surface mounted housing, with luminaire suspension eyelet (white module) 981128.002
L 340, B 170, H 75
Luminous flux factors, see NCH complete conversion kit (wattage/voltage see, NCH complete conversion kit)
H
B
L
Tender texts available upon request | Specifications subject to alteration
117
emergency Lighting | Self-Contained conversion kits
Emergency power supply unit PGVG 200 PGVG 200 is a self-contained emergency power supply unit pursuant to DIN EN 60598-2-22 for operating 1 or 2 luminaires over an operating period of 1 or 3 hours.
Similar to illustration
Max. distance between PGVG and luminaires: 200 m Type of protection: IP 33 Protection class: I Mains supply:
1/N 230 V; max. 0.25 A; 50 Hz
Output voltage:
230 V / 50 Hz (mains) 170 – 225 V (battery)
H B
L
Permissible ambient temperature: +5 to +25° C. Device is equipped with a protective earth connection.
Electronics Electronic module with charging device, 2 mains monitors, 2 changeover facilities, DC-DC converter or DC-AC converter, 2 lighting circuits, deep discharge protection disconnection and automatic self-monitoring. Non-maintained or maintained power mode of the luminaires. Separate luminaire inputs and outputs as well as control inputs for switching the luminaires by lighting circuit in mains mode. The battery is charged via input 1. In the event of a power failure on input 1 and/or input 2, the charging process will be interrupted and output 1 and/or 2 will be powered by the battery. Upon return of the mains power supply, the device switches back from battery to mains operation mode with a delay of 10 seconds.
Types Emergency power supply unit for operating 1 or 2 luminaires fitted with incandescent lamp or low pressure discharge lamp with electronic ballast, complying with self-contained system pursuant to DIN EN 60598-2-22. The indicated wattages refer to the entire device and are divided among 2 outputs. The minimum wattage for lamp control is 13 w per output. Catalogue no. Type Dimensions (LxBxH) Wattage 981502.000 NVG200-7-DC-G 510 x 200 x 100 29 W/1h 12 W/3h 981504.000 NVG200-12-DC-G 510 x 200 x 170 50 W/1h 21 W/3h 981506.000 NVG200-18-DC-G 510 x 200 x 100 74 W/1h 31 W/3h
In mains mode, the luminaires can be individually switched from nonmaintained to maintained mode via control input 1 and control input 2.
981508.000 NVG200-26-DC-G 510 x 200 x 170 106 W/1h 45 W/3h
The device switches off automatically in case of overheat, overload or short circuit during battery mode.
981512.000 NVG200-90-DC-G 950 x 240 x 190 200 W/1h 156 W/3h
Connecting diagramm PGVG 200 6
5
2
P a A E 2 2
P a A E 1 1
PE N L2 PE N L1
1 PE N L2 L1
DATA
The standard self-monitoring function provides for automatic weekly function tests (charging device, changeover facility and lighting circuits) as well as yearly service life tests (battery capacity). The luminaires will be controlled by a self-adjusting rating monitor. A display and foil button indicate operating states and malfunctions and allow for manual activation of function tests. Collective errors can be forwarded to an external alarm system via an alarm output. Battery device with maintenance-free, sealed Pb battery (service life: 6 – 9 years according to EUROBAT). The battery installation must comply with the manufacturer’s instructions. The battery must always be positioned with the pole pointing vertically upwards.
981510.000 NVG200-45-DC-G 635 x 240 x 190 183 W/1h 78 W/3h
3
Luminaire 4 can be connected to terminals 5/6.
Battery and electronics are incorporated in separate housings according to DIN EN 50272-2. Battery device with ventilation opening. Screwed housing can be folded open laterally. Wiring through cable ducts.
118
4
DATA
Mechanics
PE N (L2) L1
Tender texts available upon request | Specifications subject to alteration
emergency Lighting | Self-Contained conversion kits
Self-contained emergency conversion kits Connecting diagrams The diagrams shown below refer to emergency conversion kits with the following article numbers Standard
Self test (.03)
09-6058.000 09-6059.000 09-6083.000 09-6061.000
09-6042.000 09-6043.000 09-6044.000 09-6045.000
MultiDigit (.04) 09-6022.000 09-6023.000 09-6024.000 09-6025.000
Attention: Connection diagrams with more than one lamp: one lamp starts in emergency mode. In case your luminaires/EB are not suitable for these diagrams, please do not hesitate to contact us. We are looking forward to helping you.
Legend: DA BUS connecting terminal for DALI interface .07 ST BUS connecting terminal for PZ 50, version with self test function .03 AB BUS connecting terminal, version for MultiDigitÂŽ .04
L' L
N PE
DA DA
BUS port DALI .07
L' L
N PE
BUS port MultiDigit .04
A B
L'
L N PE
S
T
BUS port PZ50 .03
Please note: Constant phase = charging phase must always be connected to L. L’ and L must use the same phase. The circuit must be potential-free.
Connecting diagram 1: non-maintained
Connecting diagram 2: maintained, with CB/LLB for self-contained emergency conversion kits
Tender texts available upon request | Specifications subject to alteration
119
emergency Lighting | Self-Contained conversion kits
Self-contained emergency conversion kits Connecting diagrams Connecting diagram 3: maintained, with EB
EB with 6 terminals
EB with 7 terminals
EB with 8 terminals
120
Tender texts available upon request | Specifications subject to alteration
emergency Lighting | Self-Contained conversion kits
Self-contained emergency conversion kits Connecting diagrams (Turia / Edo) Turia / Edo: non-maintained, with DALI port
DALI BUS port 230 V / 50/60 Hz
DA DA N L PE
+ red - black
NiMH-Akku (NiCd)
Turia / Edo: non-maintained
230 V / 50/60 Hz
N L PE
+ red - black
NiMH-Akku (NiCd)
Turia / Edo: maintained, with DALI port
230 V / 50/60 Hz
test button
light switch
DALI BUS port
DA DA L' N L PE
+ red - black
NiMH-Akku (NiCd)
Turia / Edo: maintained
230 V / 50/60 Hz
test button
light switch L' N L PE
+ red - black
NiMH-Akku (NiCd)
Tender texts available upon request | Specifications subject to alteration
121
122
Central battery systems (CPS)
127
RZBbasic
central battery system with fused output circuits 128 - 131
LUXIFAIR
modular central battery system
(Sub-stations can be connected)
LUXIFAIRlight modular central battery system
132 - 137
138 - 140
(Sub-stations cannot be connected)
Group battery systems (LPS)
141
GV 1500
19“ group battery system
142 - 143
RZBeasy
group battery system
144 - 147
Accessories Monitoring modules, message and switchboards, etc.
148 - 157
Battery cabinets
124 - 125
123
Emergency Lighting | Central battery systems
Charging and charge maintenance device The charging and charge maintenance device’s functioning is based on the current voltage curve (I-U characteristics). The charging device is powerful enough to ensure that the battery will be recharged to 80% of its nominal capacity within 12 hours. It can also be used to charge low-maintenance and maintenance-free batteries. Charging voltage 2.40 V/Z ± 1%
wet cell batteries
2.35 V/Z ± 1%
maintenance-free batteries
1.55 V/Z ± 1% NiCd batteries Continuous charging voltage 2.23 V/Z ± 1%
wet cell batteries
2.3 V/Z ± 1%
maintenance-free batteries
1.4 - 1.45 V/Z ± 1% NiCd batteries
Battery cabinets All of the housings listed below are powder-coated and enamelled. Housing material: Sheet steel Type of protection: IP 21 Colour: Housing and doors RAL 7035 (light grey)
Type
Dimensions Catalogue no.
RZB BS0 RZB BS8.20-3G RZB BS8.21-3G
900 x 600 x 500 mm 1800 x 600 x 600 mm 1800 x 800 x 600 mm
985377 985238 985107
Other battery cabinets available on request. All doors are right hinged. Free-standing housing doors open to an angle of 180 °. Housing bases with a height of 100 or 200 mm are available for adjustment to other housings. All housings are available in other colours at extra cost. Cables can be channelled from below or above (rear) into the free-standing housings, but only from above in case of wall-mounted housings. Cable inlets from above (rear) are standard for emergency lighting equipment. The front and rear panels of all housings can be removed for transportation purposes.
V/Z lead NiCd charging
2.40 1.55
continuous charging
2.23 1.45 2.00 1.20 0%
20%
40%
60%
IN 80% 100%
Batteries - Sealed, rechargeable block batteries - Type: OGiV (other types on request) - Designlife: 10 years at 20°C ambient temperature - Extremely low gassing rate - Low self-discharge - Various capacities in 12 V blocks - 100% recyclable
124
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
Air volume flow Q [m 3/h] for ventilating the installation room
Ventilation cross sections per supply and exhaust air opening in the installation room A [cm2] (natural ventilation)
Square recess per supply and exhaust air opening, lateral length [cm]
Pipe per supply and exhaust air opening, nominal diameter [mm]
Number of battery cabinets
Battery cabinets Minimum requirements for use of 18 blocks
Dimensions of battery cabinet [B x T x H]
21,83 cm 2
4,67 cm
52,73 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
24 Ah
605 W
1414 W
3618 W
0,99 m 3/h
27,80 cm 2
5,27 cm
59,51 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
28 Ah
761 W
1782 W
4417 W
1,18 m 3/h
32,92 cm 2
5,74 cm
64,76 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
33 Ah
874 W
2030 W
4752 W
1,39 m 3/h
39,02 cm 2
6,25 cm
70,50 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
45 Ah
1166 W
2548 W
5886 W
1,92 m 3/h
53,65 cm 2
7,32 cm
82,67 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
55 Ah
1468 W
3261 W
7668 W
2,14 m 3/h
59,99 cm 2
7,75 cm
87,42 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
75 Ah
2008 W
4179 W
9558 W
3,18 m 3/h
89,01 cm 2
9,43 cm
106,48 mm
1 Stck
BS 8.20 - 3G
600 x 600 x 1800
80 Ah
2170 W
4644 W
10778 W
3,44 m 3/h
96,32 cm 2
9,81 cm
110,77 mm
1 Stck
BS 8.21 - 3G
800 x 600 x 1800
90 Ah
2386 W
5119 W
12312 W
3,88 m 3/h
108,52 cm 2
10,42 cm
117,57 mm
1 Stck
BS 8.21 - 3G
800 x 600 x 1800
100 Ah
2754 W
6145 W
14296 W
4,31 m 3/h
120,71 cm 2
10,99 cm
124,00 mm
1 Stck
BS 8.21 - 3G
800 x 600 x 1800
120 Ah
3315 W
7171 W
17064 W
5,18 m 3/h
145,09 cm 2
12,05 cm
135,95 mm
2 Stck
BS 8.21 - 3G
800 x 600 x 1800
134 Ah
3996 W
8996 W
20628 W
5,37 m 3/h
150,46 cm 2
12,27 cm
138,44 mm
1 Stck
BS 8.21 - 3G
800 x 600 x 1800
150 Ah
4158 W
8888 W
21384 W
6,23 m 3/h
174,36 cm 2
13,20 cm
149,03 mm
2 Stck
BS 8.20 - 3G
600 x 600 x 1800
200 Ah
5572 W
12528 W
28404 W
8,67 m 3/h
242,64 cm 2
15,58 cm
175,81 mm
2 Stck
BS 8.21 - 3G
800 x 600 x 1800
Max. luminaire wattage
0,78 m 3/h
3 h
2786 W
Max. luminaire wattage
1074 W
8h
429 W
Max. luminaire wattage
17 Ah
Stationary, sealed maintenance-free lead battery (OGiV)
1h
Calculating the aeration and ventilation of electr. operation rooms
Discharge data refer to 108 cells (18 blocs) at 25°.
Larger battery capacities can be achieved by parallel arrangement of identical battery types.
Example: If a battery capacity of 169 Ah and 216 V is required for 3 hours, 2 x 18 battery blocks, type BTX 12-100, are paralleled. This doubles the battery capacity from 84.60 to 168.20. This type of arrangement is recommended fort he following battery types: BTX 12-120 LS BTX 12-134 LS BTX 12-150 LS BTX 12-200 LS
Tender texts available upon request | Specifications subject to alteration
125
Emergency Lighting | Central battery systems
Central battery systems (CPS) in comparison Type of system
RZBbasic
LUXIFAIR
LUXIFAIRlight
Modular technology
•
•
•
Free programmable final circuits (maintained, non maintained)
–
•
•
DUO Control technology, mixed operation mode (maintained, non maintained, switchable mode)
–
•
•
Circuit monitoring
optional
•
•
Single luminaire monitoring (without BUS line)
optional
•
•
with Control 1
optional
–
–
Single Control
–
•
•
Duo Control
–
•
•
optional
optional
optional
UE220e (for installation in distribution boards)
optional
optional
optional
Sub distribution board
optional
optional
–
Sub-station (with same changeover and reporting functions as base)
optional
optional
–
Visualisation
–
optional
optional
Network connection
–
•
•
optional
•
–
24/42/60/110/216
216
216
Switches UE220i (for installation in luminaires)
Staircase light switching Voltage [V]
DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit Tender texts available upon request | Specifications subject to alteration
127
Emergency Lighting | Central battery systems
Central battery system (CPS) RZBbasic
For more RZBbasic options: see page 148 et seqq.
- Fully automated, processor-controlled monitoring system - Modular structure
Monitoring module CONTROL1 for installation in luminaires
- Sheet steel cabinet - Central monitoring of sub distribution boards
UE220i switch for installation in luminaires
- Free programming of all system and customer data - Single luminaire monitoring and circuit monitoring, optional - Basic version with battery voltage 216 V (220 V), other battery voltages (24 V, 42 V, 60 V, 110 V) on request - E30 or E90 twin cabinets can also be supplied upon request
UE220e switch for installation in distributors
Printer for operating status messages and testing protocols
3-phase network monitoring module
Message and switchboard
Additional RZBbasic options
Battery cabinet page 124
Type of protection: IP 21 Protection class: I RZBbasic is a series of modular systems; the number and the distribution of the circuits are to be determined beforehand. The system can be configured individually. RZBbasic comes complete with a control unit, plastic foil keyboard and four-line display. Available colour for housing and doors: RAL 7035 (light grey)
128
Sub distribution board page 131
Emergency Lighting | Central battery systems
RZBbasic installation example In case of sub distribution boards with BUS connection, please note: if the sub distribution board is more than 100 m away from the main station, it must be fitted with a BUS amplifier. Max. BUS line length: 1,000 m.
m
50
0
0
50
m
1000 m
50
m
0
0
m
50
The BUS can be connected in series or starshaped (max. 6 star points). Each system provides 2 standard BUS terminals.
circuit 4
Sub distribution board
circuit 3
Fused outlet circuits with circuit or single luminaire monitoring without changeover facility
circuit 2 circuit 1
circuit 4 circuit 3 circuit 2
circuit 2 BUS line
Luminaire (non maintained)
Luminaire (maintained)
circuit 1
circuit 1
Housing according to EN 50272 and EltBau Vo
Tender texts available upon request | Specifications subject to alteration
129
Emergency Lighting | Central battery systems
RZBbasic Components Microprocessor control and monitoring unit (standard)
- Illuminated plain text display: 4 lines with 16 characters each - Plastic foil keyboard - Buffer storage for reports and function tests dating back 2 years - 4 integrated timers for maintained light circuits control - Simple BUS connection of sub distribution boards - Potential separation of the processor unit ensures high level of interference immunity - Serial RS232 interface on the door for connection of a PC for data collection (standard) - Central control unit interface: all reports with opening and closing contact - Outgoing circuits can be individually programmed as maintained, non-maintained or switched maintained light - Simple to service thanks to the plug-in connections on all modules
Housing with charging and charge maintenance device The housing is powder-coated and enameled. All doors are right-hinged. Free-standing housing doors open to an angle of 180 °. Housing bases with a height of 100 or 200 mm are available for adjustment to other housings. All housings are available in other colours at additional cost. Available as a twin cabinet with battery compartment or electronic housing with separate battery cabinet.
Technical specifications Dimensions:
1800 x 800 x 600 mm, 1200 x 600 x 430 mm
Mains connection: Type E – single-phase alternating current 230 V 50 Hz Type D – three-phase current 400 V 50 Hz Mains voltage:
UN ± 10%
Form factor:
three-phase current: approx. 1.1; alternating current: approx. 1.4
Level of radio interference: „N“ according to VDE 0875 Housing:
Protection type IP 21
Available colour:
housing and doors RAL 7035 (light grey)
Protection class:
the appliances correspond to protection class I
Operating temperature:
0°C - 40°C at max. installation height of 1,000 m above zero level
Residual ripple:
< 5% with parallel arranged battery
130
Microprocessor control and monitoring unit
2-pole fused outgoing circuits
Battery compartment with grid trays. The grid trays provide better ventilation, especially of the middle batteries, which prolongs their service life.
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
RZBbasic Sub distribution boards Design:
steel cabinet
Paint coating: Housing and doors RAL 7035 (light grey) Type of protection: IP 21 Fitting:
up to 36 x D01/D02 or 26 x circuit breakers
Fire-protected housing also avilable. A BUS interface circuit board can also be installed (necessary for circuit or single monitoring).
Type
Dimensions
E1/UV E2/UV
600 x 400 x 250 800 x 400 x 250
Design:
max. D01/LSS 16/14 24/21
steel cabinet
Paint coating: Housing and doors RAL 7035 (light grey) Type of protection: IP 21 Ready for installation of changeover facilities, circuit monitoring or single luminaire monitoring and for BUS connection to the master device. The following must be installed if sub-stations with switching facilities are to be used: 1. Control PCB 2. Bus interface PCB 3. Network monitoring module for sub distribution board 4. Switching equipment, circuits, monitoring equipment
Type
Dimensions
E3 UV NL8.21-UV
800 x 600 x 250 1800 x 800 x 400
max. D01/D02/LSS 24/24/18 79/79/60
Fire-protected housing E-30
Tender texts available upon request | Specifications subject to alteration
Design:
30 minutes fire-protected housing, Tested in line with DIN 4102 Part 12
Attention:
Distributors and module cabinets are not equipped.
Type
Dimensions
T1 UV-E30
1000 x 730 x 400 Housing for fuses
max. D01/LSS 12/18
T2 UV-E30
1150 x 890 x 400 Housing for fuses
30/30
T3 UV-E30
2050 x 730 x 400 Module cabinet
60/72
T4 UV-E30
2050 x 1230 x 400 Module cabinet
120/120
131
Emergency Lighting | Central battery systems
Central battery system (CPS)
XIFAIR
LU
For more LUXIFAIR options: see page 148 et seqq.
- Fully automated, processor-controlled monitoring system - Compact design of center board and sub-stations - Mixed operation mode of all switching modes within one electric circuit
ECM (electric circuit module)
IO module 24 for potentialfree contacts
- Free choice of power source (Battery, EPS, second mains power supply) - Single luminaire monitoring for DC and AC networks
IO module 230 for direct mains voltage
- Integrated freely selectable single luminaire or circuit monitoring - A PC can be connected for free programming of all system and customer data - Single-wire technology to sub distribution boards - Highly secure thanks to intelligent sub-stations with sub-masters for autonomous operation mode - Integrated test log for function tests and events over a period of more than 4 years
Single Control for single luminaire monitoring
DUO Control for single luminaire monitoring and mixed operation mode
Message and switchboard
- Remote maintenance via phone or internet - SD card for programming, display texts, test log, etc. - Programming software included
Printer for operating status messages and testing protocols
Additional LUXIFAIR options
Battery cabinet page 124
Sub distribution board page 131
Type of protection: IP 21 Protection class: I RZB LUXIFAIR is a series of modular systems that can be configured individually. Available colour for housing and doors: RAL 7035 (light grey)
132
Emergency Lighting | Central battery systems
XIFAIR installation example
LU
circuit 2
circuit 4 circuit 3
circuit 1
circuit 2
circuit 4
EIB System Bus
Secure track
E30 fused junction box
circuit 3
E30 fused junction box
circuit 1
circuit 4 circuit 3 circuit 5
circuit 2 circuit 1
Housing according to EN 50272 and EltBau Vo
Tender texts available upon request | Specifications subject to alteration
133
Emergency Lighting | Central battery systems
XIFAIR
LU
Sub distribution boards Housing:
plastic/metal
Connection:
plug-in terminals, directly on the module
Available for:
surface mounting
Dimensions:
L 385 x B 295 x T 110 mm
No. of ECMs:
1
4
No. of circuits: 4 circuits Fire-protected: optional (additional cost) Manufacturer:
RZB
Type:
UV-SK1
LUXIFAIR sub distribution board UV-SK1 985288 L 385, B 295, T 110 mm
Housing:
plastic/metal
Connection:
plug-in terminals, directly on the module
Available for:
surface mounting
Dimensions:
L 385 x B 295 x T 110 mm
No. of ECMs:
2
Similar to illustration
8
No. of circuits: 8 circuits Fire-protected: optional (additional cost) Manufacturer:
RZB
Type:
UV-SK2
LUXIFAIR sub distribution board UV-SK2 985289 L 385, B 295, T 110 mm
Housing:
plastic/metal
Connection:
plug-in terminals, directly on the module
Available for:
surface mounting
Dimensions:
L 800 x B 600 x T 250 mm
No. of ECMs:
3
Similar to illustration
12
No. of circuits: 12 circuits Fire-protected: optional (additional cost) Manufacturer:
RZB
Type:
UV-SK3
LUXIFAIR sub distribution board UV-SK3 985290 L 800, B 600, T 250 mm
Similar to illustration
134
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
XIFAIR
LU
Sub distribution boards
16
Housing:
plastic/metal
Connection:
plug-in terminals, directly on the module
Available for:
surface mounting
Dimensions:
L 800 x B 600 x T 250 mm
No. of ECMs:
4
No. of circuits: 16 circuits Fire-protected: optional (additional cost) Manufacturer:
RZB
Type:
UV-SK4
LUXIFAIR sub distribution board UV-SK4 985291 L 800, B 600, T 250 mm
Similar to illustration
20
Housing:
plastic/metal
Connection:
block terminals
Available for:
surface mounting
Dimensions:
L 800 x B 600 x T 250 mm
No. of ECMs:
5
No. of circuits: 20 circuits Fire-protected: optional (additional cost) Manufacturer:
RZB
Type:
UV-SK5
LUXIFAIR sub distribution board UV-SK5 985292 L 800, B 600, T 250 mm
Similar to illustration
24
Housing:
plastic/metal
Connection:
block terminals
Available for:
surface mounting
Dimensions:
L 800 x B 600 x T 250 mm
No. of ECMs:
6
No. of circuits: 24 circuits Fire-protected: optional (additional cost) Manufacturer:
RZB
Type:
UV-SK6
LUXIFAIR sub distribution board UV-SK6 985293 L 800, B 600, T 250 mm
Similar to illustration
Version with IOM 230 or IOM 24 possible. Sub distribution boards can be configured to customerâ&#x20AC;&#x2122;s specific requirements. Fire-protected version (E 30) available upon request.
Tender texts available upon request | Specifications subject to alteration
135
Emergency Lighting | Central battery systems
XIFAIR
LU
Master
Microprocessor control and monitoring unit The Master is a freely programmable control unit that also acts as the communication interface. The Master can be supported by further submasters, which form their own self-enclosed systems, but are always managed by the Master and communicate with each other via the Master bus or exchange switching commands that apply to both Master and submasters. Each master/sub-master forms its own communication bus, thus preventing communication overload on the overall system’s bus systems. The Master unit provides all of the monitoring functions required by the applicable VDE and EN standards and is equipped with the following features: - Illuminated blue-design-display: 4 lines with 20 characters each - Plain text display of all reports - 6 membrane buttons for operating the unit - Operating states reports via LED - Buffer storage for reports and function tests dating back more than 4 years - USB – interface for connecting a PC - SD card for programming, display texts, test log etc. - 3 RS232 interfaces for expansion modules (print box, visualisation, phone line box, etc.) - Remote maintenance via phone or internet - Visualisation of the entire system on incorporated or existing PC (option) - 8 freely programmable digital inputs - Windows-compatible embOS (embedded operating system) - Programmable function keys for rapid access to frequently used functions - Plain text display of local emergency modes - Automatic search for specific luminaire addresses - 8 programmable switching options per electric circuit LUXIFAIR Master is the system‘s central intelligence. It performs all of the monitoring, log and test functions stipulated in EN 50172 and EN 50171 and stores them on an SD card. The emergency lighting system can be programmed using the illuminated display or very conveniently using a laptop/PC. LUXIFAIR Master, standard version, is equipped with a USB port. As an option the Master can also be integrated into a safety lighting substation. Housing:
plastic, grey
Display:
4 x 20 characters
Type of installation: top hat rail Operation:
6 function keys or PC via USB
Special features:
8 freely programmable inputs
Ports:
1x USB, 3x RS232 via RJ45 jacks
Dimensions: H 90 x L 157 x B 61 Space requirements: 9 module spaces (MS)
136
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
EC module installation example Note: Mixed operation possible in each circuit.
Secure track
Tender texts available upon request | Specifications subject to alteration
137
Emergency Lighting | Central battery systems
Central battery system (CPS)
XIFAIRlight
LU
- Fully automated, processor-controlled monitoring system - Battery and electronic housings made of sheet steel: can be set up separately. Dimensions: 900 x 600 x 500 mm, each housing - Mixed operation mode (DUO Control module required)
For more LUXIFAIRlight options: see page 148 et seqq.
ECM (electric circuit module)
Single Control for single luminaire monitoring
- Single changeover of each final circuit; freely programmable for maintained mode, non- maintained mode, switched maintained mode and staircase light circuit
DUO Control for single luminaire monitoring and mixed operation
- Integrated freely selectable single luminaire / circuit monitoring
Message and switchboard
- A PC can be connected for free programming of all system and customer data
Printer for operating status messages and testing protocols
- Potential-free outputs for message forwarding - Single luminaire monitoring with plain text indication of target location - Illuminated blue-design-display: 4 lines with 20 characters each, on the housing door - Plain text display of all reports - 6 membrane buttons for operating the unit - Buffer storage for reports and function tests dating back more than 4 years - USB interface for connecting a PC - Direct connection to ECM (continuous conduction mode) - Programming software included
Type of protection: IP 21 Protection class: I The LUXIFAIRlight central battery system contains all of the components stipulated in VDE 0108, part 100, VDE 0100, part 718, EN 50171 and EN 50272. Available colour for housing and doors: RAL 7035 (light grey)
138
The LUXIFAIRlight electronics housing and battery cabinet can be set up separately and can be installed wall mounted. The battery can be stored in a battery cabinet or on a support. Battery cabinets: see page 124. Supports are available on request. Please note: max. battery capacity: 100 Ah! Batteries are not included in the price.
Emergency Lighting | Central battery systems
XIFAIRlight installation example
LU
circuit 3 circuit 2
circuit 4
circuit 1
Housing in accordance with EN 50272 and EltBauVO
Charging current
ECM
Circuits
LUXIFAIR Master
Dimensions (mm)
Article number
LUXIFAIRlight 4
max. 5 A
1
4
•
900 x 600 x 500
985366
LUXIFAIRlight 8
max. 5 A
2
8
•
900 x 600 x 500
985367
LUXIFAIRlight 12
max. 5 A
3
12
•
900 x 600 x 500
985368
LUXIFAIRlight 16
max. 5 A
4
16
•
900 x 600 x 500
985369
LUXIFAIRlight 20
max. 5 A
5
20
•
900 x 600 x 500
985370
LUXIFAIRlight 24
max. 5 A
6
24
•
900 x 600 x 500
985371
LUXIFAIRlight 28
max. 5 A
7
28
•
900 x 600 x 500
985372
LUXIFAIRlight 32
max. 5 A
8
32
•
900 x 600 x 500
985373
LUXIFAIRlight 36
max. 5 A
9
36
•
900 x 600 x 500
985374
LUXIFAIRlight 40
max. 5 A
10
40
•
900 x 600 x 500
985375
900 x 600 x 500
985377
Battery cabinet and batteries are not included! Suitable battery cabinet, up to 45 Ah
Larger battery cabinets are available on request.
Tender texts available upon request | Specifications subject to alteration
139
Emergency Lighting | Central battery systems
XIFAIRlight
LU
Master
Microprocessor control and monitoring unit The Master is a freely programmable control unit that also acts as the communication interface. The Master can be supported by further submasters, which form their own self-enclosed systems, but are always managed by the Master and communicate with each other via the Master bus or exchange switching commands that apply to both Master and submasters. Each master/sub-master forms its own communication bus, thus preventing communication overload on the overall system’s bus systems. The Master unit provides all of the monitoring functions required by the applicable VDE and EN standards and is equipped with the following features: - Illuminated blue-design-display: 4 lines with 20 characters each - Plain text display of all reports - 6 membrane buttons for operating the unit - Operating states reports via LED - Buffer storage for reports and function tests dating back more than 4 years - USB – interface for connecting a PC - SD card for programming, display texts, test log etc. - 3 RS232 interfaces for expansion modules (print box, visualisation, phone line box, etc.) - Remote maintenance via phone or internet - Visualisation of the entire system on incorporated or existing PC (optional) - 8 freely programmable digital inputs - Windows-compatible embOS (embedded operating system) - Programmable function keys for rapid access to frequently used functions - Plain text display of local emergency modes - Automatic search for specific luminaire addresses - 8 programmabl switching options per electric circuit LUXIFAIR Master is the system‘s central intelligence. It performs all of the monitoring, log and test functions stipulated in EN 50172 and EN 50171 and stores them on an SD card. The emergency lighting system can be programmed using the illuminated display or very conveniently using a laptop/PC. LUXIFAIR Master, standard version, is equipped with a USB port. As an option the Master can also be integrated into a safety lighting substation. Housing:
plastic, grey
Display:
4 x 20 characters
Type of installation: top hat rail Operation:
6 function keys or PC via USB
Special features:
8 freely programmable inputs
Ports:
1x USB, 3x RS232 via RJ45 jacks
Dimensions: H 90 x L 157 x B 61 Space requirements: 9 module spaces (MS)
140
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
Group battery systems (LPS) in comparison Type of system
GV 1500
RZBeasy 202
RZBeasy 204
19” technology
•
–
–
Modular technology
•
–
–
mixed operation mode (maintained, non maintained, switchable mode)
•
•
–
Circuit monitoring
•
•
•
•
–
–
UE220i (for installation in luminaires)
•
•
•
UE220e (for installation in distribution boards)
•
•
•
4/8/12/16/20
2
4
optional
optional
optional
–
optional
optional
230/216 V
230/220 V
230/220 V
TWIN technology,
Single luminaire monitoring (without BUS wire) with Control 1 Switches
Number of circuits Visualisation Network connection Voltage [V] DC
DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit Tender texts available upon request | Specifications subject to alteration
141
Emergency Lighting | Central battery systems
Group battery system (LPS) RZB GV 1500
For more group battery system options: see page 148 et seqq.
- Fully automated, processor-controlled monitoring system - 19â&#x20AC;? slide in rack
Monitoring module CONTROL1 for installation in luminaires
- Sheet steel cabinet with control panel cover - Single changeover of each final circuit; freely programmable for maintained mode, non- maintained mode, switched maintained mode and staircase light circuit - Integrated freely selectable single luminaire or circuit monitoring - A PC can be connected free programming of all system and customer data - Single luminaire monitoring with plain text indication of target location
UE220i switch for installation in luminaires
UE220e switch for installation in distributors
3-phase network monitoring module
TWIN technology
- Twin housing with battery compartment
Message and switchboard
Printer for operating status messages and testing protocols
Type of protection: IP 21 Protection class: I The GV 1500 group battery system contains all of the components stipulated in VDE 0108 part 100, VDE 0100 part 718, EN 50171, and EN50272. Available colour for housing and doors: RAL 7035 (light grey)
142
Emergency Lighting | Central battery systems
Type of system
GV 1500/4
GV 1500/8
GV 1500/12
GV 1500/16
GV 1500/20
yes
yes
yes
yes
yes
standard
standard
standard
standard
standard
4
8
12
16
20
yes
yes
yes
yes
yes
Circuit monitoring
standard
standard
standard
standard
standard
Single luminaire monitoring without bus line, with Control 1
standard
standard
standard
standard
standard
TWIN control
optional
optional
optional
optional
optional
Light switch setting sensor module
optional
optional
optional
optional
optional
Wattage 1h
1500 W
1500 W
1500 W
1500 W
1500 W
Wattage 3h
500 W
500 W
500 W
500 W
500 W
Visualisation
optional
optional
optional
optional
optional
Voltage
230/216 V
230/216 V
230/216 V
230/216 V
230/216 V
Housing
Free-standing cabinet, twin cabinet (1200 x 600 x 430)
Free-standing cabinet, twin cabinet (1200 x 600 x 430)
Free-standing cabinet, twin cabinet (1200 x 600 x 430)
Free-standing cabinet, twin cabinet (1200 x 600 x 430)
Free-standing cabinet, twin cabinet (1200 x 600 x 430)
985212
985213
985214
985215
985216
19” technology „lightcontrol“ processor unit No. of circuits Freely programmable final circuit (maintained, non-maintained, switched maintained mode and staircase light circuit)
Catalogue number
Batteries and connectors are not included.
Batteries for group battery system (GV 1500)
TWIN control for group battery system (GV 1500)
- Sealed, rechargeable block batteries
Three circuit modes (non-maintained, maintained and switched maintained) can be simultaneously switched and operated in mixed constellation in one single circuit, thus notably reducing the number of circuits.
- Type: OGiV - Designlife: 5 years at 20°C ambient temperature - Extremely low gassing rate - Low self-discharge - 100% recyclable - 18 batteries are needed Batteries for group battery system (battery connector included) 67000.0.152
TWIN Control module for single luminaire monitoring, for installation in luminaires. Module for individually monitoring luminaires fitted with incandescent lamps, fluorescent lamps or LED with EB 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch with integrated changeover switch.
TWIN Control for luminaire wattages of up to max. 500 W 985217
TWIN Control for luminaire wattages of up to max. 1500 W 985 218
DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit Tender texts available upon request | Specifications subject to alteration
143
Emergency Lighting | Central battery systems
Group battery system (LPS) RZBeasy 202 / 204
For more group battery system options: see page 148 et seqq.
- Fully automated, processor-controlled monitoring system - For decentralized power supply to safety luminaires within one fire compartment - Sheet steel cabinet
3-phase network monitoring module
Message and switchboard
- Single luminaire / circuit monitoring - TWIN Control (mixed operation mode: maintained and non-maintained within one circuit (RZBeasy 202)) - Easy to set up
Electronic switch for dimming operation UE-DIM
- Network connection (optional) - Twin housing with battery compartment
Electronic switch with voltage control
TWIN technology
Type of protection: IP 21 Protection class: I Available colour for housing and doors: RAL 7035 (light grey)
144
Emergency Lighting | Central battery systems
RZBeasy 202 / 204 installation example (Circuit monitoring)
circuit 4 circuit 3 circuit 2 circuit 1
RZBeasy
circuit 4 circuit 3 circuit 2 circuit 1 RZBeasy
circuit 4 circuit 3 circuit 2 circuit 1
RZBeasy
Tender texts available upon request | Specifications subject to alteration
145
Emergency Lighting | Central battery systems
Type of system
RZBeasy 202
RZBeasy 202
RZBeasy 204
RZBeasy 204
Rated operating time
1h
3h
1h
3h
200 W
200 W
200 W
200 W
Single luminaire control
•
•
–
–
TWIN control
•
•
–
–
Circuit monitoring
•
•
•
•
No. of circuits
2
2
4
4
Max. no. of luminaires
32
32
80
80
Max. wattage per circuit
120 W
120 W
50 W
50 W
Min. wattage per circuit
–
–
15 W
15 W
Output voltage AC/DC
230 V / 220 V
230 V / 220 V
230 V / 220 V
230 V / 220 V
optional
optional
optional
optional
Twin housing
Twin housing
Twin housing
Twin housing
(822 x 414 x 220)
(822 x 414 x 220)
(822 x 414 x 220)
(822 x 414 x 220)
985398
985399
985396
985397
Max. total wattage
Network of up to 25 pcs. Housing Dimensions Catalogue number
Battery included.
RZBeasy 202 / 204 calculation example RZBeasy 202
RZBeasy 204
P max.
P max.
P total
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 3
Circuit 4
120 W
80 W
60 W
60 W
40 W
40 W
200 W
100 W
100 W
50 W
50 W
50 W
50 W
200 W
80 W
120 W
40 W
40 W
60 W
60 W
200 W
Total maximum wattage: 200 W !
146
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
RZBeasy 202 / 204 connecting diagram Circuit direction
F3
11 12 13 14
F4 F29
15 16
Maintained, group 1 Maintained, group 2
31 32 33
Message emergency mode disabled
34 35
Error message contact - no error MP Error message contact - error Maual control, non-maintained (BS) 12 VDC plus Fire detection system switch 12 VDC minus Emergency lighting blocking - F NWC Network monitoring 12 V +NW Emergency lighting blocking - f Luminaire group 2 Luminaire group 1 Output 2a Output 1a Output 1b Output 2b Critical circuit / mains monitor
N / minus L / plus earth
4 5 6
Mains mode signal MP Battery mode signal
N / minus L / plus earth
F2
PE (Mains connection) N (Mains connection) L (Mains connection)
N / minus L / plus earth
1 2 3
N / minus L / plus earth
F1
21 22 20
23 24 20
25 26 20
27 28 20
F21 F22
F23 F24
F25 F26
36 37 38 39 40 41 42
Address
Module
Address input
F27 F28 Button LM Test
EC-Interface
LED LM Test
Tender texts available upon request | Specifications subject to alteration
147
Emergency Lighting | Central battery systems
Accessories Type
RZBbasic
LUXIFAIR
LUXIFAIRlight
GV 1500
RZBeasy
3-phase network monitoring module
•
•
•
•
•
Message and switchboard (surface mounting)
•
•
•
•
•
Printer for operating status messages and testing protocols
•
•
•
•
–
UE220i switch for installation in luminaires
•
•
•
•
•
UE220e switch for installation in distributors
•
•
•
•
•
Electronic switch for dimming operation
•
•
•
•
•
Electronic switch with voltage control
•
•
•
•
•
ECM (electric circuit module)
–
•
•
–
–
IOM 24 for potential-free contacts
–
•
–
–
–
IOM 230 for direct power supply voltage
–
•
–
–
–
SINGLE CONTROL for single luminaire monitoring
–
•
•
–
–
DUO CONTROL for single luminaire monitoringand mixed operation
–
•
•
–
–
optional
–
–
•
–
TWIN technology
–
–
–
•
•
Remote control tableau, type: MTB-BUS
–
–
–
•
–
Universal changeover unit, type: UUE 4/220 / 4/220-80
–
–
–
•
–
LSM 24
–
–
–
•
–
LSM 230
–
–
–
•
–
LSM 24/230
–
–
–
•
–
Monitoring module CONTROL1
Light switch setting sensor modules (LSM)
148
Emergency Lighting | Central battery systems
ACCESSORIES FOR ALL CPS AND LPS SYSTEMS 3-phase network monitoring module Type of protection:
IP 20
Protection Class: II Input voltage: 230/400 V 50/60 Hz
H
Own rating: < 4VA Min. operating value: 85% of nominal voltage Contact set: 2 change-over relays, potential-free L
B
Installation: C profile track Display: LED OFF if power fails Suiteable for installation in systems complying with DIN VDE 0108. For installation in sub distribution boards for detecting undervoltage and power failures in single-phase or three-phase power systems. Construction width: 35 mm. 3-phase network monitoring module for all systems 985147 L 59, B 35, H 59
Message and switchboard (surface mounting) Type of protection: IP 32 H
Protection Class:
II
In accordance with DIN VDE 0100 part 718 L
B
Displays:
- Operational readiness of the system
- Battery mode
- Collective error
Switches: maintained mode ON/OFF Installation: surface mounting Housing:
plastic, grey
Terminals: 1.5 mm2 Message and switchboard (surface mounting) without battery for RZBbasic and GV 1500 985256 L 70, B 54, H 135 for LUXIFAIR and LUXIFAIRlight 985364 L 70, B 54, H 135 for RZBeasy 202 / 204 985402 L 150, B 40, H 200
Printer for operating status messages and testing protocols VDE 0108 Part 100 stipulates that emergency lighting operated by central battery system must be function-tested every day of operation and the results be recorded in a protocol. Manual testing and recording in writing can be eliminated by implementation of an automatic testing facility with protocol printer. All errors and system status changes are recorded with indication of date and time. The elimination of the faults is indicated with date and time. Printer for RZBbasic, LUXIFAIR, LUXIFAIRlight and GV 1500 985138 L 100, B 100, H 50
Tender texts available upon request | Specifications subject to alteration
149
Emergency Lighting | Central battery systems
ACCESSORIES FOR ALL CPS AND LPS SYSTEMS UE220i switch for installation in luminaires
Installation example
Electronic switch for luminaires with electronic ballasts (EB) and incandescent lamps in emergency lighting systems according to DIN VDE 0108
L N PF
Mains light switch
Thanks to the UE220i switch, luminaires can be used both for general and for emergency lighting.
N L
When voltage is present on the emergency power supply, the switch disconnects the luminaire from the general lighting power supply system. The time lag in switching eliminates any spark gaps in the changeover facility (relays), thus ensuring safe disconnection from the power supply. UE220i is a switch for installation in luminaires; the relevant installation instructions must be followed. Input voltage:
General lighting power supply: 230 V AC (+/- 10%)
Emergency power supply: 220 V DC (+/- 20%)
General lighting
+ -
Non-maintained circuit
Switching capacity: 250VA
B
H
NL+
Ue220i
EB
Luminaire
Group battery Central battery
L
Ambient temperature: -5 to +50 째C Changeover time:
100 ms
Switching power:
250 VA (short circuit proof 20 x Inom)
Housing:
plastic, black
L N PF
Suiteable for installation in systems complying with DIN VDE 0108-100 EN50172.
Mains light switch
General lighting N L
UE220i switch for all systems 981352.003 L 130, B 46, H 31
Non-maintained circuit
Switching capacity: 250VA
L N PF
Mains light switch
UE220e electronic switch for C and top hat rail (installation in distribution boards)
General lighting power supply: 230 V AC (+/- 10%)
Emergency power supply: 220 V DC (+/- 20%)
Ambient temperature: -5 to +50 째C Changeover time:
Non-maintained circuit
H
Group battery Central battery
+ -
Ue220i
NL+
Switching capacity: 250VA
EB
Luminaire
B
L
100 ms
Switching power:
500 VA (short circuit proof 20 x Inom)
Housing:
plastic, grey
Suiteable for installation in systems complying with DIN VDE 0108-100 EN50172.
UE 220e for all systems 981353.009
150
General lighting N L
Thanks to the UE220e switch, luminaires can be used simultaneously both for general and for emergency lighting. When voltage is present on the emergency power supply, the switch disconnects the luminaire from the general lighting power supply system. Input voltage:
EB
Luminaire
Group battery Central battery
UE220e switch for installation in distribution boards
NL+
Ue220i
+ -
Installation example UE220i (in luminaire) Please note: UE220e can only be installed in a distribution board.
L 96, B 48, H 50
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
ACCESSORIES FOR ALL CPS AND LPS SYSTEMS Electronic switch for dimming operation Switching module for operating dimmable, combined safety luminaires on mains and emergency power supplies H
B
L
L N PF
Version for: - Selective changeover from non-maintained to maintained power mode during mains operation, depending on the switching mode of the general lighting - Dimming luminaires in mains mode via a 1-10V interface - Dimming luminaires in emergency mode via integrated potentiometer Control: - Switched phase on general lighting system
External light control for EB with 1-10 V control
- 1-10V signal from lighting control
Mains light switch
Input voltage:
General lighting power supply: 230 V AC (+/- 10%) Emergency power supply: 220 V DC (+/- 20%)
Ambient temperature: -5 to +50 째C N L + -
Non-maintained circuit
12 3
NL+
UE-DIM
Switching capacity: 250VA
EB
100 ms
Switching power:
250 VA (short circuit proof 20 x Inom)
Housing:
plastic, grey
Suiteable for installation in systems complying with DIN VDE 0108-100 EN50172.
Luminaire
Group battery Central battery
Changeover time:
UE-DIM for all systems 09-6230.000
L 175, B 42, H 32
Electronic switch with voltage control Switching module for operating dimmable, combined safety luminaires on mains and emergency power supplies
B
H
Version for: - Selective changeover from non-maintained to maintained power mode during mains operation, depending on the switching mode of the general lighting - Selective activation in emergency mode depending on the general lighting power supply Control: - Switched phase on general lighting system
L
- Non- switched phase on general lighting system External light control for EB with 1-10 V control
L N PF
Mains light switch
General lighting
+ -
Group battery Central battery
Input voltage:
General lighting power supply: 230 V AC (+/- 10%)
Emergency power supply: 220 V AC/DC (+/- 20%)
Ambient temperature: -5 to +50 째C L L N
Non-maintained circuit
- Codable function
Network monitoring inactiv
Switch TW 200
activ
NL+
Switching capacity: 250VA
EB
Luminaire
Tender texts available upon request | Specifications subject to alteration
Changeover time:
100 ms
Switching power:
250 VA (short circuit proof 20 x Inom)
Housing:
plastic, black
Suiteable for installation in systems complying with DIN VDE 0108-100 EN50172.
TW 200 for all systems 09-6202.009
L 130, B 45, H 32
151
Emergency Lighting | Central battery systems
ACCESSORIES FOR LUXIFAIR and LUXIFAIRlight ECM (electric circuit module)
ECM (electric circuit module)
The EC module is a bus-controlled electric circuit switching module. Fitted with a range of comfortable features, it offers both superior operational reliability and comprehensive monitoring technology. The safety or escape route luminaires are operated via the EC module. All 4 output circuits on the module can be used both for circuit-monitored systems and for single luminaire monitoring.
Rating per circuit:
815 VA
Rating per module:
3260 VA
Fuse protection per circuit:
6.15 Ampere, 2-pole
Connecting terminals:
plug-in terminals, up to 1.5 mm²
Circuit monitoring:
standard
Each module can operate 4 outgoing circuits with up to 20 luminaires each. Each outgoing circuit is protected by a 6.3 A (2-pole) fuse and can be switched individually. Max. voltage per electric circuit: 815 VA.
Addressing:
2 rotary code switches
Dimensions:
L 157 x B 61 x H 90
Space requirement:
6 module spaces (MS)
Type of installation:
top hat rail
Housing:
plastic, grey
Each circuit of the lighting circuit assembly can be programmed in maintained power mode, non-maintained power mode, switched maintained power mode or mixed operation. The switching commands are transmitted via the mains power supply cable to the luminaire, without the need for an additional bus line. Single luminaire monitoring is also possible with the use of an NEA or secondary secured power supply as substitute source of power without the need for an additional test battery.
ECM for LUXIFAIR and LUXIFAIRlight 985272 L 157, B 61, H 90
Each circuit can be switched via the IO-module. Status LEDs display the switching states of the outgoing circuits as well as the emergency mode. Error LEDs display fuse failures, luminaire malfunctions and overloads, thus facilitating troubleshooting considerably. The information button offers the option of multiple error selection. The ES module is suitable for use in the base, in intelligent sub-stations or, as separate entity, for supplying individual fire compartments. It is connected to the master unit via the system bus.
ECM installation example Note: Mixed operation possible in each circuit. max. 20 luminaires or 815 VA
max. 20 luminaires or 815 VA
Secure track
max. 20 luminaires or 815 VA
max. 20 luminaires or 815 VA
EIB System Bus
152
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
ACCESSORIES FOR LUXIFAIR and LUXIFAIRlight IO-Modul Light switch setting sensor modules These modules allow for final circuit switching in mains mode using the switches or contactors of the mains power supply lighting. The IO modules are suitable for installation in the base or sub-station. They are connected to the base via the 2-core system bus. The IO modules are programmed via the LUXIFAIR master unit.
X1:
1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 E1 E2 E3 E4 E5 E6 E7 E8
H V
17 19 21 23 25 27 29 31 18 20 22 24 26 28 30 32 E9 E10 E11 E12 E13 E14 E15 E16
Digitale Eingänge f.pot.-freie Kontakte
IOM 24 for potential-free contacts The input ports can interrogate a maximum of 16 circuits. Each input can be assigned to one or several outgoing circuits. Requests are transmitted via potential-free contacts. Each input had a LED status display.
X1: 41 42
43 44
Contacts:
16 x 24 V via external potential-free contacts
Type of installation:
top hat rail
Connecting terminals: up to 1.5 mm² Addressing:
2 rotary code switches
Dimensions:
L 105 x B 61 X H 90
Space requirement:
6 module spaces (MS)
Housing:
plastic, grey
IOM 24 for LUXIFAIR 985273 L 105, B 61 , H 90
X1:
1N 1L 2N 2L 3N 3L 4N 4L 5N 5L 6N 6L E1
E2
E3
E4
E5
E6
Digitale Eingänge für 230VAC Kontaktbelegung N - L
IOM 230 for direct power supply voltage The input ports can interrogate a maximum of 9 circuits. Each input can be assigned to one or several outgoing circuits. Requests are transmitted via 230 V AC.
X1: 41 42
43 44
E9 E8 E7 L1
L2
L3
N
3 LEDs display the status of the power monitoring module. The master unit displays the power failure of the IO module with programmable plain text indication of location. The IOM 230 can be configured with: 9 x 230 V AC switch inputs or 6 x 230 V switch inputs + 3ph network monitoring module or 8 x 230 V switch inputs + 1ph network monitoring module Each input has a LED status display. Type of installation:
top hat rail
Connecting terminals: up to 1.5 mm² Addressing:
2 rotary code switches
Dimensions:
L 105 x B 61 X H 90
Space requirement:
6 module spaces (MS)
Housing:
plastic, grey
IOM 230 for LUXIFAIR 985274 L 105, B 61, H 90
Tender texts available upon request | Specifications subject to alteration
153
Emergency Lighting | Central battery systems
ACCESSORIES FOR LUXIFAIR and LUXIFAIRlight SINGLE Control for single luminaire monitoring
H B
Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch.
L Type of protection:
IP 20
Dimensions:
L 81 x B 33 x H 24
Input voltage
230 V AC (+ 10% / - 15%) 230 V DC (+ 20% / - 20%)
Housing:
plastic, grey
SINGLE Control
for EB and incandescent lamps 2-120 W EB
Address +20 Address +10
0 0 8-120 W
2-6 W
Single Control for LUXIFAIR and LUXIFAIRlight 985280 L 81, B 33, H 24
Output max. 120W
NL+
Output max. 120 W
Address allocation module is to be addressed!
SINGLE Control
NL+
Address 1 = 10 = 11 = 20 =
Please note: + and - must not be reversed!
Output circuits from central battery system
+20 0 +10 0 Tens 0 10 10 20
Single + +1 +1 +1 +0
LUXIFAIR Central battery
DUO Control for single luminaire monitoring and mixed operation mode
H B
Module for monitoring single luminaires of 2-120 W. The use of a DUO Control module allows for mixed operation of maintained and nonmaintained luminaires within the same circuit. Individual circuits can be switched using the inputs of the IO module. Luminaire addresses can be set manually using an externally accessible rotary code switch.
L
The DUO Control module is also fitted with an invertible switch input. Type of protection:
IP 20
Dimensions:
L 81 x B 33 x H 24
Input voltage: Housing:
230 V AC (+10% / -15%) 230 V DC (+20% / -20%) plastic, grey
Address allocation module is to be addressed!
DUO Control
for EB and incandescent lamps 2-120 W EB
Address +20
0
Address +10
0
2-6 W Network monitoring
DS Output max. 120W
Duo Control LUXIFAIR and LUXIFAIRlight 985279 L 81, B 33, H 24
Output circuits from central battery system
LUXIFAIR Central battery
NL+
Address 1 = 10 = 11 = 20 =
+20 0 +10 0 Tens 0 10 10 20
Single + +1 +1 +1 +0
8-120 W Input
BS
DUO Control
N-
N-
L+
L+
Please note: + and - must not be reversed!
The following can be connected: Single-phase network monitoring
Input Network monitoring
The connected luminaire switches on in the event of a failure of the impressed phase or Input If the general lighting switch is connected, the luminaire can be swithed via said genral lighting switch.
154
Tender texts available upon request | Specifications subject to alteration
men L und N uerspannung schaltweiche angelegt.
N- Klemmen Anschluss zur die Polarit채t scht werden.
Emergency Lighting | Central battery systems
ACCESSORIES FOR GV 1500 AND RZBeasy Monitoring module CONTROL1
H
Illustration below: Terminals L/L+ and N/N+ (mains side) are the connection to the emergency power unit; the poles must not be switched.
B
Type of protection:
IP 20
Dimensions:
L 106 x B 36 x H 24
Input voltage:
230 V AC (+10% / -15%)
230 V DC (+20% / -20%)
Ambient temperature:
-5째C bis 50째C
Housing:
plastic, white
Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch.
L L/+ must always be connected L/+
N/N-
Input
L/L+
L/+ EB
2-12 W N/-
13-48 W 49-120 W
CONTROL1 for RZBeasy and GV 1500 981348.002 L 106, B 36, H 24 mm
N/-
N/- depending on the performance of the luminaire or EB
TWIN technology Three power modes (non-maintained, maintained and switched maintained power mode) can be installed and operated within the same circuit, thus reducing the number of electric circuits.
H B
L
Single luminaire monitoring module TWIN Control for installation in luminaires Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch, with integrated changeover switch. Type of protection:
IP 20
Dimensions:
L 115 x B 34 x H 23
Control voltage for changeover switch:
230 V AC (+10% / -10%)
Input voltage:
230 V AC (+10% / -15%) , 220 V DC (+/- 20%)
Ambient temperature:
-5 to + 50째C
Housing:
plastic, white
Suiteable for installation in systems complying with DIN VDE 0108-100 EN50172. Radio interference suppression according to EN55015. Illustration below: Control voltage for the internal switch
TWIN-Control for RZBeasy and GV 1500 981705.002 L 115, B 34, H 23 mm
only is connected to terminals L and N. Terminals L/L+ and N/N+ (mains side) are the connection to the emergency power unit; the poles must not be switched.
{
N L
49-120W N/- 13-48W 2-12W N/NInput L/+ L/L+
N/- depending on the performance of the luminaire or EB N/-
L/-
EB
L/+ must always be connected
Tender texts available upon request | Specifications subject to alteration
155
Emergency Lighting | Central battery systems
ACCESSORIES FOR GV 1500 Remote control tableau Type: MTB-BUS - Connection via 3-core bus line - Surface mounted version with window in the housing - Illuminated plain text display, 4 lines, 16 characters each - Membrane keyboard - Battery voltage display
Bus line 2 x 2 x 0,8 NYM 1 x 3 (for 220V DC auxiliary voltage)
- Charging/discharging current display - Voltage display of all 3 supply phases - Test log display - Luminaire error display - Error display in plain text - Online - Failure - Mains supply mode / battery mode - Maitained on / non-maintained on - Testing mode - Switch system on/off - Switch maintained light on/off - Start of functions test and capacity test - Selection of configuration and information menu The remote control tableau can also be used as a display unit for substations. Remote control tableau for GV 1500 985021
Universal changeover unit Type: UUE 4/220 All four output circuits of the plug-in units can be used both for circuitmonitored systems and for single luminaire monitoring. Mixed operation of single luminaire and circuit monitoring is also possible. The monitoring function can be subsequently modified from circuit to single luminaire monitoring at any time by means of simple re-configuration, without the need to exchange the hardware. Each plug-in unit can operate 4 output circuits, with up to 16 luminaires each. Each output circuit is protected by a 6.3 A (1.25 A) (2-pole) fuse and can be switched individually. Each circuit in the lighting circuit assembly can be individually programmed. The integrated staircase light switch mode allows for time-controlled switching in mains and emergency mode using the lighting power supply buttons (switch-on time 1 â&#x20AC;&#x201C; 15 minutes, individually adjustable for each circuit.) Universal changeover unit, type UUE 4/220 for GV 1500 985019
Universal changeover unit, type UUE 4/220-80 for up to 80 W total for GV 1500 985195
156
Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Central battery systems
ACCESSORIES FOR GV 1500 Light switch setting sensor module (LSM) This module allows for final circuit switching in mains mode using the switches or contactors of the mains power supply lighting. The input ports can interrogate a maximum of 16 circuits. Each input can be programmed as a staircase light switch for timecontrolled switching of emergency lighting (1-15 minutes). Option: The LSM modules can also be integrated in external distributors. (Max. length of BUS line: 100 m).
Sensor module LSM 24 Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via potentialfree contacts. Light switch setting sensor module LSM 24 for GV 1500 985054
Light switch setting sensor module LSM 230 Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via an external 230 V AC voltage. Light switch setting sensor module LSM 230 for GV 1500 985055
Sensor module LSM 24â&#x20AC;&#x2030;/â&#x20AC;&#x2030;230 Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via an external 230 V AC voltage (8 inputs), as well as via potential-free contacts (8 inputs). Light switch setting sensor module LSM 24/230 for GV 1500 985182
Tender texts available upon request | Specifications subject to alteration
157
158
LED
LED
160
162 - 163
LED
162, 164
LED
162, 165
LED
166 LED
168
170 LED
172 - 174
172 - 174
176, 177
LED
LED
Luminaires for central emergency power supply Tenuo
160
LED Halyxx®
162
Ilustris
166
Display
168
Flat Sign Mini/Midi
170
Design
172
Rechteck 250 / 360 / 485
176
Multivariabel
182
Luminaires for sports facilities 184 176, 178
176, 179 LED
188, 190
188, 192
198
208 - 210
188, 192 LED
200
212 - 214
224
186
188, 189
LED
LED
LED
222
182 - 185
LED
202
216
226
196
194 LED
204
218
228
LED
206
220
230 LED
230
232
234
236
238
Standardleuchten
184
Signcube
186
Rechteck (Universal 2)
189
Universal 3
190
Universal 3 LED
191
Universal 4
192
Universal 4 LED
193
LCS‑Z
194
Varioplast I
196
Turia
198
Edo
200
Lucio
202
Centryxx
204
Solyxx
206
Energo TC 175
208
Energo TC 210
210
Andho TC Flat
212
Andho TC Flat IP 65
214
Arelo®
216
Mondana
218
Flat Polymero®
220
Flat Polymero® PMMA/PC
222
Flat Basic
224
Flat Polymero® Rechteck
226
Rounded® superflach
228
Alu‑Lux oval
230
Alu‑Rund
230
Light Case
232
Safety striplights
234
Alu‑Druckguss
236
Recessed LED step luminaire for installation in concrete steps
238
159
Emergency Lighting | Luminaires for central emergency power supply Tenuo Type of protection: IP 40
Motifs for escape route identification â&#x20AC;&#x201C; Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- The flattest existing emergency luminaire that incorporates the very latest energy saving LED technology - Ultraflat - (panel 5 mm) frame 8 mm
1003
1004
- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
1113
1115
1114
1116
- Top quality LED technology - Specially calculated thermal management - The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours
1005
- Exceptionally high luminance of over 900 cd/m2 - Wide range of applications thanks to various types of installation
Wall extension
160
Wall (semi-recessed)
Ceiling (surface)
Ceiling (recessed)
Pendant tube
Suspension cable/chain
Emergency Lighting | Luminaires for central emergency power supply Series: Tenuo Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 30 m For escape route identification Housing: aluminium, silver Display panel with patented MicroLens technology. LED included. Please indicate symbol number when placing your order! Ballast: EB
30 m m 30
Available colour (X): 4 = aluminium, anodised
Wall (surface)
Wall extension
Wall (semi-recessed)
Wall (surface)
Ceiling (recessed)
Suspension cable/chain
Pendant tube
LP L
B
L
H
LA
B
L
Installation scheme available on request
Installation scheme available on request
H
H
B
BA
LA L
Installation scheme available on request
LP
HE
HA H
H
H
L
TE B
Installation scheme available on request
L
H
B
L
B
Installation scheme available on request
Installation scheme available on request
Installation scheme available on request
Dimensions
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
30 m
1 x LED 2,5 W
•
•
•
•
Wall extension
30 m
1 x LED 5 W
•
•
•
•
L 400, B 60, H 200 L 350, B 11, H 200, LA 173, BA 173, TE 70
Article number
Type of installation
671923.00X.Y 671938.00X.Y
L 350, B 33, H 200
671922.00X.Y
Wall (semi-recessed)
30 m
1 x LED 2,5 W
•
•
•
•
671939.00X.Y
Ceiling (surface)
30 m
1 x LED 5 W
•
•
•
•
L 350, B 50, H 240
671940.00X.Y
Ceiling (recessed)
30 m
1 x LED 5 W
•
•
•
•
L 420, B 40, H 252, LA 400, BA 40, HE 90
671941.00X.Y
Pendant tube Suspension cable/chain
30 m
1 x LED 5 W
•
•
•
•
L 350, B 50, H 200, LP 500
30 m
1 x LED 5 W
•
•
•
•
L 350, B 50, H 200, LP 500
671942.00X.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
B
161
Emergency Lighting | Luminaires for central emergency power supply LED HalyxxÂŽ Type of protection: IP 40
Motifs for escape route identification â&#x20AC;&#x201C; Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- High quality aluminium housing - High quality and elegant design - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - Specially calculated thermal management
1003
1004
1113
1115
1114
1116
- The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours - Luminance exceeds 500 cd/m2
1005
- Wide range of applications thanks to various types of installation - Moulded housing for concrete available - Easy to install
Wall (surface)
162
Ceiling (surface)
Ceiling (recessed)
Wall (recessed)
Emergency Lighting | Luminaires for central emergency power supply Series: LED Halyxx® Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 14 m Ceiling thickness: 5-35 mm Wall thickness: 1-30 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides. LED included. Please specify legend number when ordering!
14 m
Ballast: EB Available colour (X): 4 = aluminium, anodised
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
Wall (recessed) (cavity wall)
L
Ø4,5 23
L
B
45
15
3
12,5
15
180
H
LA L
B
50
150 233
B
Ø5
L
HA H LA
LA
1-30
42
220 200
150
150
132
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
14 m
2 x LED 1,1 W
•
•
•
•
Ceiling (surface)
14 m
2 x LED 1,1 W
•
•
•
•
L 233, B 40, H 180
Type of installation
671503.00X.Y 671504.00X.Y
L 233, B 40, H 180
671519.00X.Y
Ceiling (recessed)
14 m
2 x LED 1,1 W
•
•
•
•
L 270, B 55, H 100 LA 255 x BA 42, HE 90
671547.12X.Y
Wall (recessed) (cavity wall)
14 m
1 x LED 3,5 W
-
-
-
-
L 220, B 150, H 2 LA 210 x BA 132, HE 90
671547.00X.Y
Wall (recessed) (solid wall)
14 m
1 x LED 3,5 W
-
-
-
-
L 220, B 150, H 2 LA 200 x BA 130, HE 80
Wall extension Viewing distance: 14 m 981581.004 L 258, B 38, H 104
130
Dimensions
Viewing distance
Article number
B
HA H
220 210
55
HE
BA
270 255
16
40
151 233
5-35
H
H
HE B
L
HE
Wall (recessed) (solid wall)
for art. 671504.004.Y
Accessories | Pendant set for ceiling luminaires Suspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site. Pendant sets Viewing distance: 14 m 981639.020 for .82 981639.060 for .71/.81
Mounting set for suspension cable/chain Viewing distance: 14 m 981701.004 L 213, B 33, H 77
for art. 671504.004.Y
Moulded housing Viewing distance: 14 m 981685.000 L 542, B 142, H 143
for art. 671519.004.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
163
Emergency Lighting | Luminaires for central emergency power supply Series: LED Halyxx® Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 19 m Ceiling thickness: 5-35 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides. LED included. Please specify legend number when ordering! 19 m
Ballast: EB Available colour (X): 4 = aluminium, anodised
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
HE
L
B
Ø4,5 23
H
15
L
5-35
H
H LA L
B
BA B
45 3
50
15
12,5
220
320 305
16
40
150 233
151 235
55
Ø5
42
Dimensions
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
19 m
2 x LED 1,1 W
•
•
•
•
L 235, B 40, H 220
Ceiling (surface)
19 m
2 x LED 1,1 W
•
•
•
•
L 235, B 40, H 220
Ceiling (recessed)
19 m
2 x LED 1,1 W
•
•
•
•
L 320, B 55, H 140 LA 305 x BA 42, HE 90
Article number
Type of installation
671738.00X.Y 671736.00X.Y 671739.00X.Y
Wall extension Viewing distance: 19 m 981581.004 L 258, B 38, H 104
for art. 671738.004.Y
Accessories | Pendant set for ceiling luminaires Suspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site. Pendant sets Viewing distance: 19 m 981639.020 for .82 981639.060 for .71/.81
Mounting set for suspension cable/chain Viewing distance: 19 m 981701.004 L 213, B 33, H 77
for art. 671736.004.Y
Moulded housing Viewing distance: 19 m 981686.000 L 542, B 142, H 143
for art. 671739.004.Y
164
For connecting diagrams, see pages 119 - 121 | Article number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Luminaires for central emergency power supply Series: LED Halyxx® Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 30 m Ceiling thickness: 5-35 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides. LED included. Please specify legend number when ordering! 30 m
Ballast: EB Available colour (X): 4 = aluminium, anodised
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
L
B
Ø4,5 23
H
25
L
5-35
HE H
H LA L
B
BA B
45 3 15
270
25 Ø5
424 410
27,5
40
270 340
10,5
55
42
250 340
Dimensions
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
30 m
3 x LED 1,1 W
•
•
•
•
L 340, B 40, H 270
Ceiling (surface)
30 m
3 x LED 1,1 W
•
•
•
•
L 340, B 40, H 270
Ceiling (recessed)
30 m
3 x LED 1,1 W
•
•
•
•
L 424, B 55, H 190 LA 410 x BA 42, HE 90
Article number
Type of installation
671722.00X.Y 671737.00X.Y 671740.00X.Y
Wall extension Viewing distance: 30 m 981640.000 L 363, B 38, H 104
for art. 671722.004.Y
Accessories | Pendant set for ceiling luminaires Suspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site. Pendant sets Viewing distance: 30 m 981647.000 for .71/.81 981647.020 for .82
Mounting set for suspension cable/chain Viewing distance: 30 m 981702.004 L 318, B 33, H 57
for art. 671737.004.Y
Moulded housing Viewing distance: 30 m 981687.000 L 542, B 142, H 143
for art. 671740.004.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
165
Emergency Lighting | Luminaires for central emergency power supply Ilustris Type of protection: IP 20 - Design matches modern architectural styles - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - The very latest LED technology keeps maintenance costs to a minimum - LED service life: approx. 50,000 hours - Large viewing distance - Wide range of applications thanks to various types of installation
Wall (surface)
166
Ceiling (surface)
Emergency Lighting | Luminaires for central emergency power supply Series: Ilustris Type of protection: IP 20 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 30 m For escape route identification Housing: die-cast aluminium, powder-coated. 3 foils with escape route motif and 1 white foil included. LED included. Ballast: EB Available colour (X): 31 = anthracite metallic
30 m
Wall (surface)
Ceiling (surface)
H
H
B
L
35
150
22
B
L
55
253
368 100 368
26
5,5x10
120 Ø5,5
Article number
Type of installation
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671843.00X.Y
Wall (surface)
30 m
1 x LED 3 W
-
-
-
•
L 368, B 55, H 253
671847.00X.Y
Ceiling (surface)
30 m
1 x LED 3 W
-
-
-
•
L 368, B 27, H 263
Wall extension 981775.0031
L 300, B 150, H 35
Pendant tube 981777.0131 981777.0231
Pendant lenght 500 mm Pendant length 500 mm
Suspension cable/chain 981776.000 Pendant lenght 1500 mm
–
– for .82
–
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
167
Emergency Lighting | Luminaires for central emergency power supply Display Type of protection: IP 40
Motifs for escape route identification â&#x20AC;&#x201C; Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- Absolutely uniform illumination of the motifs - Wide range of applications thanks to various types of installation - Designed for large viewing distances - Standard fluorescent lamps can be used - Specifically calculated reflector inside the luminaire
1003
1004
1113
1115
1114
1116
1005
Wall (surface)
168
Ceiling (surface)
Ceiling (recessed)
Emergency Lighting | Luminaires for central emergency power supply Series: Display Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 32 m Ceiling thickness: 1-40 mm For escape route identification Base: powder-coated metal; plastic display panel wit motifs on one side/both sides. EB incorporated. Lamp included. Please specify legend number when ordering! 32 m
Ballast: EB Available colours (X): 2 = white, 4 = silver metallic
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
LA 1-40
BA
H
HE
H H
B
L
B
L
B
L
276
15
43 18
5x8 332 276
56 16
400
236 18
96
84
68
57 5x8
380
332
Article number
Type of installation
671180.75X.Y
Wall (surface)
32 m
671178.75X.Y
Ceiling (surface)
32 m
671179.75X.Y
Ceiling (recessed)
Viewing distance
32 m
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x T16 (T5) 8 W
•
•
•
•
1 x T16 (T5) 8 W
•
•
•
•
L 332, B 57, H 270
•
L 400, B 84, H 180 LA 380 x BA 68, HE 105
Lamp/Wattage
1 x T16 (T5) 8 W
•
•
•
L 332, B 70, H 236
Accessories | Wall extension Steel bracket, white powder-coated Wall extension 981489.002
Accessories | Pendant set Suspension tube, square: 40 x 40 mm, powder-coated, suspension length 500 mm (other lengths available upon request) Pendant kit 90-3757.002 90-3757.004
Pendant length 500 mm Pendant length 500 mm
white silver metallic
Moulded housing 981586.000
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
169
Emergency Lighting | Luminaires for central emergency power supply Flat Sign Mini/Midi Type of protection: IP 43
Motifs for escape route identification â&#x20AC;&#x201C; Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- Exclusive luminaire design - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)
1003
1004
1113
1115
1114
1116
- Top quality LED technology - Uniform light distribution provided by special LED arrangement - 2 different housing dimensions for different viewing distances
1005
Wall (surface)
170
Pendant tube
Emergency Lighting | Luminaires for central emergency power supply Series: Flat Sign Mini/Midi Type of protection: IP 43 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 21 m, 32 m For escape route identification Housing: powder-coated sheet steel; display panel: plastic, opal, with motifs on one side/both sides. LED included. Please specify legend number when ordering! Ballast: EB
21 m/32 m
Available colour (X): 2 = white
Wall (surface) Mini
Wall (surface) Midi
Pendant tube
LP H
L
H
B
L
B
H B
L
60
27
9x5 8
Ø20
Ø10
9x5
125
178
Ø20
120 237
10
27
30
Ø3,5
237 348
Dimensions
Viewing distance
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
21 m
Mini
2 x LED 1,1 W
•
-
•
•
L 237, B 84, H 125
671556.00X.Y
Wall (surface)
32 m
Midi
3 x LED 1,1 W
•
•
•
•
L 348, B 84, H 178
671557.00X.Y
Pendant tube
21 m
Mini
4 x LED 1,1 W
•
-
•
•
L 237, B 138, H 125, LP 480
671607.00X.Y
Pendant tube
32 m
Midi
6 x LED 1,1 W
•
•
•
•
L 348, B 138, H 178, LP 480
Article number
Type of installation
671555.00X.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
171
Emergency Lighting | Luminaires for central emergency power supply Design Type of protection: IP 40
Motifs for escape route identification â&#x20AC;&#x201C; Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- Flat aluminium housing in elegant design - Installation-friendly design enables lamp replacement without tools - Designed for large viewing distances - Wide range of applications thanks to various types of installation - Luminaire also available for escape route illumination
1003
1004
1113
1115
1114
1116
1005
Wall (surface), Ceiling (surface)
172
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Emergency Lighting | Luminaires for central emergency power supply Series: Design Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 26 m For escape route identification Housing: aluminium, powder-coated; plastic panel: opal, with motifs on one side/on two sides. EB incorporated. Please indicate symbol number when placing your order! Ballast: EB Available colour (X): 2 = white
26 m
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
LP H
H
H
190
H
L
B
B
L
B
L
L
B
18
294
15
340
5,5x10
90 190
190
75
6
169,5
42
52,5
27 210
55 5x12
340
6
60
52,5
Ø6
82
82
55
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x T16 (T5) 6 W
•
•
•
•
L 294, B 55, H 190
26 m
1 x T16 (T5) 6 W
•
•
•
•
L 314, B 55, H 190
Ceiling (surface)
26 m
1 x T16 (T5) 6 W
•
•
•
•
L 340, B 55, H 232
Pendant tube
26 m
1 x T16 (T5) 6 W
•
•
•
•
L 340, B 55, H 190, LP 524
Article number
Type of installation
Viewing distance
671597.75X.Y
Wall (surface)
26 m
671599.75X.Y
Wall extension
671598.75X.Y 671600.75X.Y
Lamp/Wattage
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
173
Emergency Lighting | Luminaires for central emergency power supply Series: Design Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 33 m For escape route identification Housing: aluminium, powder-coated; plastic panel: opal, with motifs on one side/on two sides. EB incorporated. Please indicate symbol number when placing your order! Ballast: EB Available colour (X): 2 = white
33 m
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
LP H
H
H
228
H
L
B
B
L
B
L
L
28
370
47
55
90
117 228
416 228
42
55 53
5x10
283
6
208
5x12
Article number
Type of installation
Viewing distance
53
Ø6
671185.75X.Y
Wall (surface)
33 m
671188.75X.Y
Wall extension
33 m
82 82
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x T16 (T5) 8 W
•
•
•
•
L 370, B 55, H 228
1 x T16 (T5) 8 W
•
•
•
•
L 390, B 55, H 228
Lamp/Wattage
6
60
18
6x16
416
B
671186.75X.Y
Ceiling (surface)
33 m
1 x T16 (T5) 8 W
•
•
•
•
L 416, B 55, H 270
671312.75X.Y
Pendant tube
33 m
1 x T16 (T5) 8 W
•
•
•
•
L 416, B 55, H 228, LP 500
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
174
For connecting diagrams, see pages 119 - 121 | Article number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Luminaires for central emergency power supply Series: Design Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: aluminium, powder-coated; plastic panel: transparent, prismatic inside; reflector: aluminium, highly polished anodised finish, wide beam. EB incorporated. Ballast: LLB/EB Available colour (X): 2 = white
Wall (surface), Ceiling (surface)
8W
Wall (surface), Ceiling (surface)
H L
35
44
44
Article number
Type of installation
Lamp/Wattage
64
117 228
317
44
B
1605
64
6x16
615
58 W
H L
1305
120 228
Viewing distance
Wall (surface), Ceiling (surface)
B
695
52
6x16
36 W
H L
B
370
117 228
Wall (surface), Ceiling (surface)
H L
B
64
18 W
44
117 228
313
44
6x16
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
44
6x16
Dimensions
671181.75X.Y
Wall (surface), Ceiling (surface)
-
1 x T16 (T5) 8 W
•
•
•
•
L 370, B 228, H 55
671182.75X.Y
Wall (surface), Ceiling (surface)
-
1 x T26 (T8) 18 W
•
•
•
•
L 695, B 228, H 55
671183.75X.Y
Wall (surface), Ceiling (surface)
-
1 x T26 (T8) 36 W
•
•
•
•
L 1305, B 228, H 55
671184.75X.Y
Wall (surface), Ceiling (surface)
-
1 x T26 (T8) 58 W
•
•
•
•
L 1605, B 228, H 55
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Spacing table 671184.752
Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Mains: 5400 lm, Emergency: 5400 lm
Lamp luminous flux: The following values are indicated in m
Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
h
a
b
c
d
2.5
14.8
6.4 21.5
9.0
3.0
16.1
7.1 22.5
9.9
3.5
17.6
7.8 24.6 10.7
4.0
18.5
8.5 27.0 11.4
Spacing table 671181.752
Spacing table 671182.752
Spacing table 671183.752
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 450 lm, Emergency: 450 lm
Mains: 1350 lm, Emergency: 1350 lm
Mains: 3350 lm, Emergency: 3350 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
d
h
a
d
h
a
2.5
8.4
3.5 10.6
4.6
2.5
10.6
4.7 15.0
6.3
2.5
13.2
5.8 18.0
8.0
3.0
8.7
3.8 11.8
4.9
3.0
12.2
5.2 15.8
6.8
3.0
14.4
6.5 20.4
8.8
3.5
9.7
3.9 12.6
5.1
3.5
12.5
5.5 16.9
7.3
3.5
15.9
7.0 21.9
9.4
4.0
10.0
4.0 13.5
5.3
4.0
14.0
5.9 18.4
7.7
4.0
16.9
7.5 22.4 10.0
c
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
b
c
b
c
d
175
Emergency Lighting | Luminaires for central emergency power supply Rechteck 250 / 360 / 485 Type of protection: IP 44
Motifs for escape route identification â&#x20AC;&#x201C; Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green
- High quality aluminium profile housing - Installation-friendly conctruction facilitates easy lamp replacement - Wide range of applications thanks to various types of installation - Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support - Available also with exceptionally long service life and energy efficient LED technology
1003
1004
1113
1115
1114
1116
- LED conversion sets are available for existing luminaires 1005
Wall (surface)
176
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
Emergency Lighting | Luminaires for central emergency power supply Series: Rechteck 250 Type of protection: IP 44 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 21 m For escape route identification Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides. Lamp included. Please specify legend number when ordering! Ballast: EB
21 m
Available colours (X): 2 = white, 4 = aluminium, anodised
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
40
40
H
80
H
B
L
B
L
L
40
33
Ø5
125 80
40 140 6x16
41
140 80
18
41
12
12
Ø6 9
80 68
11
55
6x12
40
6x18 40
40 250
40
H H
B
L
LP
40 H
30
80
40
40
80
250
70
125
125
B
L
B
4x10
50
60
250
Dimensions
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
21 m
2 x LED 1,1 W
•
•
•
•
L 250, B 90, H 140
Wall (surface)
21 m
1 x T16 (T5) 6 W
•
•
•
•
L 250, B 90, H 140
Article number
Type of installation
671207.00X.Y 671207.75X.Y
50
125
85 250
55
30
671256.00X.Y
Wall (surface)
21 m
2 x CO26 15 W
-
-
-
-
L 250, B 90, H 140
671208.00X.Y
Wall extension
21 m
4 x LED 1,1 W
•
•
•
•
L 250, B 125, H 140
671209.75X.Y
Wall extension
21 m
1 x T16 (T5) 6 W
•
•
•
•
L 250, B 125, H 140
671258.00X.Y
Wall extension
21 m
1 x E27 25 W
-
-
-
-
L 250, B 125, H 140
671211.00X.Y
Ceiling (surface)
21 m
4 x LED 1,1 W
•
•
•
•
L 250, B 125, H 140
671211.75X.Y
Ceiling (surface)
21 m
1 x T16 (T5) 6 W
•
•
•
•
L 250, B 125, H 140
671260.00X.Y
Ceiling (surface)
21 m
1 x E27 25 W
-
-
-
-
L 250, B 125, H 140
671213.00X.Y
Pendant tube
21 m
4 x LED 1,1 W
•
•
•
•
L 250, B 125, H 140, LP 500
671213.75X.Y
Pendant tube
21 m
1 x T16 (T5) 6 W
•
•
•
•
L 250, B 125, H 140, LP 500
671262.00X.Y
Pendant tube
21 m
1 x E27 25 W
-
-
-
-
L 250, B 125, H 140, LP 500
671359.00X.Y
Suspension cable/chain Suspension cable/chain Suspension cable/chain
21 m
4 x LED 1,1 W
•
•
•
•
L 250, B 125, H 140
21 m
1 x T16 (T5) 6 W
•
•
•
•
L 250, B 125, H 140
21 m
1 x E27 25 W
-
-
-
-
L 250, B 125, H 140
671359.75X.Y 671357.00X.Y
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
177
Emergency Lighting | Luminaires for central emergency power supply Series: Rechteck 360 Type of protection: IP 44 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 32 m For escape route identification Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides. Lamp included. Please specify legend number when ordering! Ballast: EB
32 m
Available colours (X): 2 = white, 4 = aluminium, anodised
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
40
40
H
H
B
L
B
L
L
40
33
Ø6
40
125 9 11
12 192
6x16
6x18
40 362
40
H H
B
L
LP
40
40
H
30
80
40
40
80
40
Ø5
Ø5
6x18 40
55
12
192
40
12
12
9
80 68
55
Ø6
11
55
68 80
362
70
125
125
B
L
B
4x10
50
60 85 362
55
Dimensions
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
32 m
3 x LED 1,1 W
•
•
•
•
L 362, B 90, H 192
671215.75X.Y
Wall (surface)
32 m
1 x T16 (T5) 8 W
•
•
•
•
L 362, B 90, H 192
671264.00X.Y
Wall (surface)
32 m
2 x IT-3 30 25 W
-
-
-
-
L 362, B 90, H 192
671217.00X.Y
Wall extension
32 m
6 x LED 1,1 W
•
•
•
•
L 362, B 125, H 192
671217.75X.Y
Wall extension
32 m
1 x T16 (T5) 8 W
•
•
•
•
L 362, B 125, H 192
671266.00X.Y
Wall extension
32 m
2 x E27 25 W
-
-
-
-
L 362, B 125, H 192
671223.00X.Y
Ceiling (surface)
32 m
6 x LED 1,1 W
•
•
•
•
L 362, B 125, H 192
671223.75X.Y
Ceiling (surface)
32 m
1 x T16 (T5) 8 W
•
•
•
•
L 362, B 125, H 192
Type of installation
671215.00X.Y
50
362
Viewing distance
Article number
30
125
671268.00X.Y
Ceiling (surface)
32 m
2 x E27 25 W
-
-
-
-
L 362, B 125, H 192
671227.00X.Y
Pendant tube
32 m
6 x LED 1,1 W
•
•
•
•
L 362, B 125, H 192, LP 500
671227.75X.Y
Pendant tube
32 m
1 x T16 (T5) 8 W
•
•
•
•
L 362, B 125, H 192, LP 500
671270.00X.Y
Pendant tube
32 m
2 x E27 25 W
-
-
-
-
L 362, B 125, H 192, LP 500
671363.00X.Y
Suspension cable/chain Suspension cable/chain Suspension cable/chain
32 m
6 x LED 1,1 W
•
•
•
•
L 362, B 125, H 192
32 m
1 x T16 (T5) 8 W
•
•
•
•
L 362, B 125, H 192
32 m
2 x E27 25 W
-
-
-
-
L 362, B 125, H 192
671363.75X.Y 671361.00X.Y
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
178
For connecting diagrams, see pages 119 - 121 | Article number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Luminaires for central emergency power supply Series: Rechteck 485 Type of protection: IP 44 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 43 m For escape route identification Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides. Lamp included. Please specify legend number when ordering! Ballast: EB
43 m
Available colours (X): 2 = white, 4 = aluminium, anodised
Wall (surface)
Wall extension
Ceiling (surface)
Pendant tube
Suspension cable/chain
40
40
H
40
40
H
H
H
B
L
B
L
33
Ø6
40
125 9 11
12 250
6x16
6x18
40 485
40
Ø5
Ø5
12
250
40
6x18 40
55
12
12
11
55
68 80
Ø6 9
80 68
55
485
B
L B
L
40
40
LP
H
B
L
30
80
40
40
80
70
4x10
60
125
125
50
55
50
85
485
Dimensions
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
43 m
4 x LED 1,1 W
•
•
•
•
L 485, B 90, H 250
Wall (surface)
43 m
1 x T26 (T8) 15 W
•
•
•
•
L 485, B 90, H 250
Article number
Type of installation
671229.00X.Y 671229.75X.Y
50
125
50
485
30
671272.00X.Y
Wall (surface)
43 m
2 x IT-3 30 40 W
-
-
-
-
L 485, B 90, H 250
671231.00X.Y
Wall extension
43 m
8 x LED 1,1 W
•
•
•
•
L 485, B 125, H 250
671231.75X.Y
Wall extension
43 m
1 x T26 (T8) 15 W
•
•
•
•
L 485, B 125, H 250
671274.00X.Y
Wall extension
43 m
2 x E27 40 W
-
-
-
-
L 485, B 125, H 250
671233.00X.Y
Ceiling (surface)
43 m
8 x LED 1,1 W
•
•
•
•
L 485, B 125, H 250
671233.75X.Y
Ceiling (surface)
43 m
1 x T26 (T8) 15 W
•
•
•
•
L 485, B 125, H 250
671276.00X.Y
Ceiling (surface)
43 m
2 x E27 40 W
-
-
-
-
L 485, B 125, H 250
671235.00X.Y
Pendant tube
43 m
8 x LED 1,1 W
•
•
•
•
L 485, B 125, H 250, LP 500
671235.75X.Y
Pendant tube
43 m
1 x T26 (T8) 15 W
•
•
•
•
L 485, B 125, H 250, LP 500
671278.00X.Y
Pendant tube
43 m
2 x E27 40 W
-
-
-
-
L 485, B 125, H 250, LP 500
671367.00X.Y
Suspension cable/chain Suspension cable/chain Suspension cable/chain
43 m
8 x LED 1,1 W
•
•
•
•
L 485, B 125, H 250
43 m
1 x T26 (T8) 15 W
•
•
•
•
L 485, B 125, H 250
43 m
2 x E27 40 W
-
-
-
-
L 485, B 125, H 250
671367.75X.Y 671365.00X.Y
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
179
Emergency Lighting | Luminaires for central emergency power supply
LED conversion kits It’s so easy to save money You can start right now to convert existing emergency luminaires of series Rechteck 250, 360 and 485 from incandescent or fluorescent lamp versions to LED versions. HOW? It‘s quite simple and easy: just use our LED conversion kits for luminaires for central emergency power supply.
Accessories | Sets for converting luminaires for LED lamps
Protection class: I
Low-cost conversion of rectangular luminaires with T16 6 W or common incandescent lamps into luminaires with energy-efficient, long-life LEDs. The conversion set can be clicked in any existing housing without needing to use any tool and can be connected to the existing power supply cable. Modules’ plate: powder-coated aluminium sheet, ballasts and connecting terminal included. Sets for converting luminaires of series „Rechteck 250“ for LED lamps 981722.002 single sided 2 x LED 1,1 W 981722.002.81 single sided 2 x LED 1,1 W 981722.002.82 single sided 2 x LED 1,1 W 981722.002.71 single sided 2 x LED 1,1 W 981722.002.72 single sided 2 x LED 1,1 W 981723.002 double sided 4 x LED 1,1 W 981723.002.71 double sided 4 x LED 1,1 W 981723.002.72 double sided 4 x LED 1,1 W 981723.002.81 double sided 4 x LED 1,1 W 981723.002.82 double sided 4 x LED 1,1 W Sets for converting luminaires of series „Rechteck 360“ for LED lamps 981725.002 single sided 3 x LED 1,1 W 981725.002.71 single sided 3 x LED 1,1 W 981725.002.72 single sided 3 x LED 1,1 W 981725.002.81 single sided 3 x LED 1,1 W 981725.002.82 single sided 3 x LED 1,1 W 981727.002 double sided 6 x LED 1,1 W 981727.002.71 double sided 6 x LED 1,1 W 981727.002.72 double sided 6 x LED 1,1 W 981727.002.81 double sided 6 x LED 1,1 W 981727.002.82 double sided 6 x LED 1,1 W Sets for converting luminaires of series „Rechteck 485“ for LED lamps 981759.002 single sided 4 x LED 1,1 W 981759.002.71 single sided 4 x LED 1,1 W 981759.002.72 single sided 4 x LED 1,1 W 981759.002.81 single sided 4 x LED 1,1 W 981759.002.82 single sided 4 x LED 1,1 W 981760.002 double sided 8 x LED 1,1 W 981760.002.71 double sided 8 x LED 1,1 W 981760.002.72 double sided 8 x LED 1,1 W 981760.002.81 double sided 8 x LED 1,1 W 981760.002.82 double sided 8 x LED 1,1 W
Very easy „press and clip“ mounting. The conversion kit can be inserted in any existing luminaire housing without needing any tool NOR screws:
Just take the metal brackets ...
180
... press them together and ...
... click them into the luminaire housing.
For connecting diagrams, see pages 119 - 121 | Article number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Luminaires for central emergency power supply
Energy efficiency and costs Rechteck 360 in maintained mode (24h/day)
LED
Fluorescent lamp
Incandescent lamp
Lamp wattage
4W
8W
2 x 25 W
50,000 h
3,000 h
1,000 h
Total consumption in 1 year (8,760 h) in kWh
35.04 kWh
70.08 kWh
438.00 kWh
Power supply costs in 1 year (at 0.19 €/kWh)
6.66 €
13.32 €
83.22 €
175.20 kWh
350.40 kWh
2,190.00 kWh
33.29 €
66.58 €
416.10 €
0
14
43
0.00 €
107.10 €
118.68 €
Average time needed for replacing a lamp (minutes)
15 min.
10 min.
10 min.
Costs for replacing lamps (caretaker 25.00 €/h)
0.00 €
58.33 €
179.17 €
33.29 €
232.01 €
713.95 €
Service life in hours
Total consumption in 5 years (43,800 h) in kWh Power supply costs in 5 years (at 0.19 €/kWh) Number of lamps needed in 5 years (43,800 h) Costs for lamps in 5 years
Total costs in 5 years (power supply, lamps, lamp replacement)
The correct arrangement of the LEDs was calculated by our photometry lab, which allows us to minimize the number of LEDs, without impairing the required luminance values laid down in DIN 4844, Part 1 (luminance of more than 500cd/m2 for the contrast colour). Thanks to a clever heat management, we are able to drastically reduce heat stress fort he LEDs, preventing thus an early LED failure. Average LED service life: approx. 50,000 hours!
Costs comparison over a period of 5 years
Incandescent lamps 2 x 25 W 713.95 €
= costs for power supply = costs for lamps = lamp replacement costs
T16 8W 232.01 €
LED 4W 33.29 €
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
181
Emergency Lighting | Luminaires for central emergency power supply Multivariabel Type of protection: IP 54 - Industrial Design - IP 54 type of protection - dustproof and protected against water spray - Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support - Different types of installation for one sole luminaire - Lamp replacement without tools
Spacing table 671377.912
Lamp luminous flux: Mains: 900 lm, Emergency: 900 lm The following values are indicated in m
- Easy to install
h
a
b
2.5
9.1
3.8 12.2
c
5.0
d
3.0
10.0
4.0 12.1
5.2
3.5
9.6
4.1 13.1
5.3
4.0
9.9
4.2 13.7
5.4
Spacing table 671376.752
Lamp luminous flux: Mains: 450 lm, Emergency: 450 lm The following values are indicated in m h
a
b
c
d
2.5
7.2
2.9
9.3
3.8
3.0
7.9
2.9 10.2
3.8
3.5
7.4
2.9
9.7
3.8
4.0
7.2
2.8 10.6
3.6
Spacing table 671374.912
Lamp luminous flux: Mains: 600 lm, Emergency: 600 lm The following values are indicated in m h
a
b
2.5
8.3
3.2 10.0
c
4.2
d
3.0
8.6
3.4 11.2
4.3
3.5
9.1
3.4 11.8
4.4
4.0
8.4
3.4 11.1
4.4
Spacing table 671373.752
Lamp luminous flux: Mains: 300 lm, Emergency: 300 lm The following values are indicated in m
Wall (surface), Ceiling (surface)
h
a
b
c
d
2.5
5.7
2.4
8.4
3.1
3.0
6.3
2.3
8.2
3.1
3.5
5.9
2.2
7.7
2.9
4.0
6.5
1.9
8.0
2.6
Pendant tube Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
182
Emergency Lighting | Luminaires for central emergency power supply Series: Multivariabel Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 22 m For escape route identification or escape route illumination Base: aluminium, powder-coated. Canopy: white. Pendant tube: chrome. Diffuser: plastic, opal, 3 foils for escape route identification included. Ballast: EB Available colour (X): 2 = white
22 m
Wall (surface), Ceiling (surface)
Pendant tube
LP
H L
H
B L
80
370
20
130
Ø6 40
Article number
30
30
B
40
Type of installation
45 50
4x14
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671374.91X.Y
Wall (surface), Ceiling (surface)
22 m
1 x TC-EL 9 W
•
•
•
•
L 275, B 130, H 130
671377.91X.Y
Wall (surface), Ceiling (surface)
22 m
1 x TC-EL 11 W
•
•
•
•
L 370, B 130, H 130
671373.75X.Y
Wall (surface), Ceiling (surface)
22 m
1 x T16 (T5) 6 W
•
•
•
•
L 275, B 130, H 130
671376.75X.Y
Wall (surface), Ceiling (surface)
22 m
1 x T16 (T5) 8 W
•
•
•
•
L 370, B 130, H 130
671372.00X.Y
Wall (surface), Ceiling (surface)
22 m
2 x E14 25 W
-
-
-
-
L 275, B 130, H 130
671375.00X.Y
Wall (surface), Ceiling (surface)
22 m
2 x E14 25 W
-
-
-
-
L 370, B 130, H 130
671380.91X.Y
Pendant tube
22 m
1 x TC-EL 9 W
•
•
•
•
L 275, B 130, H 130, LP 500
671383.91X.Y
Pendant tube
22 m
1 x TC-EL 11 W
•
•
•
•
L 370, B 130, H 130, LP 500
671379.75X.Y
Pendant tube
22 m
1 x T16 (T5) 6 W
•
•
•
•
L 275, B 130, H 130, LP 500
671382.75X.Y
Pendant tube
22 m
1 x T16 (T5) 8 W
•
•
•
•
L 370, B 130, H 130, LP 500
671378.00X.Y
Pendant tube
22 m
2 x E14 25 W
-
-
-
-
L 275, B 130, H 130, LP 500
671381.00X.Y
Pendant tube
22 m
2 x E14 25 W
-
-
-
-
L 370, B 130, H 130, LP 500
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185 981168.002 L 540, B 375, H 185
for L 275 for L 370
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
183
Emergency Lighting | Luminaires for central emergency power supply Luminaires for sports facilities Type of protection: IP 30 - Compact design - Available also as ball impact proof version - Different types of installation for one sole luminaire - Installation-friendly construction - Industrial design - Easy lamp replacement
Spacing table 671237.912
Lamp luminous flux: Mains: 600 lm, Emergency: 600 lm The following values are indicated in m h
a
b
2.5
7.5
3.2 10.1
c
4.2
d
3.0
8.6
3.4 11.2
4.4
3.5
8.7
3.4 11.5
4.4
4.0
8.5
3.3 11.2
4.4
Spacing table 671236.912
Lamp luminous flux: Mains: 600 lm, Emergency: 600 lm The following values are indicated in m
Wall (recessed)
Wall (surface), Ceiling (surface)
h
a
b
2.5
7.5
3.2 10.1
c
4.2
d
3.0
8.6
3.4 11.2
4.4
3.5
8.7
3.4 11.5
4.4
4.0
8.5
3.3 11.2
4.4
Pendant tube Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
184
Emergency Lighting | Luminaires for central emergency power supply Series: Luminaires for sports facilities Type of protection: IP 30 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 14 m For escape route identification or escape route illumination Base: galvanised sheet steel; diffuser: plastic, opal, 3 foils for escape route identification included. Version with TC-EL-Lp: EB incorporated Ballast: EB Available colour (X): 2 = white
14 m
Wall (recessed) (cavity wall)
BA
Wall (recessed) (solid wall)
BA
B
LA
65
66
65
40
75
14 31
90
220
Ø5
182
B
L
230
14
H
B
L
H
L
230
75
LP H
HE
H
Pendant tube
B
LA
HE L
Wall (surface), Ceiling (surface)
66
14 230 86
14 31
5x15
75
75
20
220
230
60
183
max. 30
Article number
Type of installation
Viewing distance
ball impact proof
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671308.00X.Y
Wall (recessed) (cavity wall)
14 m
-
1 x E14, IT-2 20 25 W
-
-
-
-
L 230, B 75, H 5 LA 220 x BA 66, HE 65
671286.00X.Y
Wall (recessed) (solid wall)
14 m
-
1 x E14, IT-2 20 25 W
-
-
-
-
L 230, B 75, H 5 LA 220 x BA 66, HE 65
671288.00X.Y
Wall (recessed) (solid wall)
14 m
•
1 x E14, IT-2 20 25 W
-
-
-
-
L 230, B 75, H 5 LA 220 x BA 66, HE 65
671309.91X.Y
Wall (recessed) (cavity wall)
14 m
-
1 x TC-EL 9 W
•
-
•
•
L 230, B 75, H 5 LA 220 x BA 66, HE 65
671287.91X.Y
Wall (recessed) (solid wall)
14 m
-
1 x TC-EL 9 W
•
-
•
•
L 230, B 75, H 5 LA 220 x BA 66, HE 65
671289.91X.Y
Wall (recessed) (solid wall)
14 m
•
1 x TC-EL 9 W
•
-
•
•
L 230, B 75, H 5 LA 220 x BA 66, HE 65
671283.00X.Y
Wall (surface), Ceiling (surface)
14 m
-
1 x E14, IT-2 20 25 W
-
-
-
-
L 230, B 75, H 76
-
-
-
-
L 230, B 75, H 76
1 x E14,
671284.00X.Y
Wall (surface), Ceiling (surface)
14 m
-
671236.91X.Y
Wall (surface), Ceiling (surface)
14 m
-
1 x TC-EL 9 W
•
-
•
•
L 230, B 75, H 76
671237.91X.Y
Wall (surface), Ceiling (surface)
14 m
•
1 x TC-EL 9 W
•
-
•
•
L 230, B 75, H 76
-
-
-
-
L 230, B 75, H 76, LP 500
•
-
•
•
L 230, B 75, H 76, LP 500
671285.00X.Y
Pendant tube
14 m
-
671238.91X.Y
Pendant tube
14 m
-
IT-2 20 25 W
1 x E14,
IT-2 20 25 W
1 x TC-EL 9 W
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
185
Emergency Lighting | Luminaires for central emergency power supply Signcube Type of protection: IP 40 - Motifs on four sides - Plastic cube (PMMA) - For large viewing distances - Wide range of applications thanks to various types of installation - Excellent light distribution on the cubeâ&#x20AC;&#x2DC;s surface - Suspension can be shortened on side - Easy to install - Available with high quality LED technology
Wall (surface), Ceiling (surface)
Special motifs in accordance with BGV A8
186
Pendant tube
Suspension cable/chain
Emergency Lighting | Luminaires for central emergency power supply Series: Signcube Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 24 m For escape route identification Base: powder-coated metal; canopy: plastic, white; pendant tube: metal, chrome (can be shortened on site); diffuser: plastic (PMMA), opal; 3 motif foils for escape route identification included (according to DIN 4844, UVV GBV A8 and EWGR 92/58), EB incorporated. Ballast: EB Available colour (X): 2 = white
24 m
Wall (surface), Ceiling (surface)
Suspension cable/chain
Pendant tube Ø108
B
B LP
H
H
H
L
L
255 190
L
B
255
60
110 255
Ø3,5
28
30
10
38
190 255
107
27
Article number
38
Ø10
Ø4,5x9
Type of installation
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671601.00X.Y
Wall (surface), Ceiling (surface)
24 m
8 x LED 1,1 W
•
•
•
•
L 255, B 255, H 276
671601.92X.Y
Wall (surface), Ceiling (surface)
24 m
1 x TC-DEL 13 W
•
•
•
•
L 255, B 255, H 276
671826.00X.Y
Pendant tube
24 m
8 x LED 1,1 W
•
•
•
•
L 255, B 255, H 291, LP 510
671602.92X.Y
Pendant tube
24 m
1 x TC-DEL 13 W
•
•
•
•
L 255, B 255, H 291, LP 510
671822.00X.Y
Suspension cable/chain Suspension cable/chain
24 m
8 x LED 1,1 W
•
•
•
•
L 255, B 255, H 300
24 m
1 x TC-DEL 13 W
•
•
•
•
L 255, B 255, H 300
671612.92X.Y
Accessories | Legend foils in accordance with UVV BGV A8 and EECR 92/58 Viewing distance 48 m Replacement foils 991116 991117 991118
Motif foil 240 x 240 Motif foil 240 x 240 Motif foil 240 x 240
Motif 2003 Motif 2004 Motif 2005
2003
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
2004
2005
187
Emergency Lighting | Luminaires for central emergency power supply Rechteck (Universal 2) Type of protection: IP 44 - All-plastic luminaire, shockproof - Classic design - Installation benefits in case of protection class II - 3 foils for escape route identification included - Low-cost installation
Universal 3 / Universal 4 Type of protection: IP 54 - All-plastic luminaire, shockproof - IP 54 type of protection - dustproof and protected against water spray - Can be used for all types of installation (with accessories) - Low power consumption - 3 foils for escape route identification included - Low-cost installation
Universal 3 LED / Universal 4 LED Type of protection: IP 54 - All-plastic luminaire, shockproof - IP 54 type of protection - dustproof and protected against water spray - Can be used for all types of installation (with accessories) - Reliable and long-lasting LED technology - Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology) - LED service life: approx. 50,000 hours - 3 foils for escape route identification included - Low-cost installation
Wall (surface) Rechteck (Universal 2)
188
Wall (surface), Ceiling (surface) Universal 3 / Universal 3 LED
Wall (surface), Ceiling (surface) Universal 4 / Universal 4 LED
Wall (surface) Universal 4 / Universal 4 LED
Emergency Lighting | Luminaires for central emergency power supply Series: Rechteck (Universal 2) Type of protection: IP 44 Protection class: II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 19 m For escape route identification or escape route illumination Base: plastic. Diffuser: plastic, opal. 3 foils for escape route identification included. Integrated EB (where necessary). Ballast: EB Available colours (X): 2 = white, 3 = black 19 m
Wall (surface)
H
B
L
214
25
114 85
85
25 6x10
Dimensions
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Wall (surface)
19 m
1 x E27 25 W
-
-
-
-
L 215, B 115, H 110
Wall (surface)
19 m
1 x TC-EL 7 W
-
-
-
-
L 215, B 115, H 110
Article number
Type of installation
671253.00X.Y 671254.91X.Y
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671253.00X
Spacing table 671254.91X
Lamp luminous flux:
Lamp luminous flux:
Mains: 400 lm, Emergency: 400 lm
Mains: 400 lm, Emergency: 400 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
6.1
1.9
6.2
3.6
2.5
6.1
1.9
6.2
3.6
3.0
5.2
1.5
6.8
3.5
3.0
5.2
1.5
6.8
3.5
3.5
4.9
0.6
6.5
3.3
3.5
4.9
0.6
6.5
3.3
4.0 - - - -
4.0 - - - -
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
189
Emergency Lighting | Luminaires for central emergency power supply Series: Universal 3 Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 21 m For escape route identification or escape route illumination Base: plastic. Diffuser: plastic, opal. Foil with escape route motif included. Ballast: EB Available colour (X): 2 = white 21 m
Wall (surface), Ceiling (surface) (high hood)
H L
B
Planning guide: Escape route illumination in accordance with EN 1838 a c
b
5x11
70
13
100
13 80
d
h
126
100 240
E = 1 lx along the centre line
Article number
Type of installation
Luminous flux factor
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671384.00X.Y
Wall (surface), Ceiling (surface)
21 m
high hood
1 x E27 60 W
-
-
-
-
L 240, B 126, H 145
671387.92X.Y
Wall (surface), Ceiling (surface)
21 m
high hood
1 x TC-DEL 10 W
•
•
•
•
L 240, B 126, H 145
671386.91X.Y
Wall (surface), Ceiling (surface)
21 m
high hood
1 x TC-EL 7 W
•
•
•
•
L 240, B 126, H 145
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13
Spacing table 671387.912
Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Mains: 600 lm, Emergency: 600 lm
Wire guard for wall luminaires 981167.002 L 380, B 295, H 185 Accessories | Wall extension Steel, white powder-coated Wall extension 981144.002
190
The following values are indicated in m h
a
b
c
d
2.5
7.6
3.3
9.7
3.9
3.0
8.0
3.1
9.6
4.0
3.5
7.8
3.1 10.1
3.9
4.0
8.3
3.0 11.0
3.8
L 251, B 131, H 60
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
Lamp luminous flux:
LP 500 mm
Spacing table 671386.912
Lamp luminous flux: Mains: 400 lm, Emergency: 400 lm The following values are indicated in m h
a
b
c
d
2.5
6.6
2.5
8.2
3.3
3.0
6.8
2.5
8.5
3.2
3.5
7.1
2.4
8.1
3.1
4.0
6.7
2.1
8.7
2.8
For connecting diagrams, see pages 119 - 121 | Article number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Luminaires for central emergency power supply Series: Universal 3 LED Type of protection: IP 54 Protection class: II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 21 m For escape route identification Base: plastic. Diffuser: plastic, opal. Foil with escape route motif included. LED included. Ballast: EB Available colour (X): 2 = white
21 m
Wall (surface), Ceiling (surface) (high hood)
Wall (surface), Ceiling (surface) (flat hood)
H
H L
B
5x11
5x11
70
13
100
13 80
B
L
70
13
100
126
100 240
13 80
126
100 240
Dimensions
Viewing distance
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLE‑ Control (.81)
DUOControl (.82)
Wall (surface)
21 m
flat hood
1 x LED 2,1 W
•
•
•
•
L 240, B 126, H 78
Wall (surface), Ceiling (surface)
21 m
high hood
1 x LED 2,1 W
•
•
•
•
L 240, B 126, H 145
Article number
Type of installation
671775.00X.Y 671782.00X.Y
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981167.002 L 380, B 295, H 185 Accessories | Wall extension Steel, white powder-coated Wall extension 981144.002
L 251, B 131, H 60
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
LP 500 mm
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
191
Emergency Lighting | Luminaires for central emergency power supply Series: Universal 4 Type of protection: IP 54 Protection class: II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 21 m, 25 m For escape route identification (only wall installation) or escape route illumination Base: plastic (polycarbonate), diffuser: plastic (polycarbonate), opal, or refractor, plastic (polycarbonate) transparent, prismatic, motif foil included, EB incorporated. Ballast: EB Available colour (X): 2 = white
21 m/25 m
Wall (surface), Ceiling (surface) (high hood) opal
Wall (surface), Ceiling (surface) (flat hood) transparent, prismatic
H
H L
L
B
B
Planning guide: Escape route illumination in accordance with EN 1838 a c
b
5x11
15
148,5 110
5x11 50 144
112,5
15
148,5 110 50 144
112,5
250 344
d
h
250 344
E = 1 lx along the centre line
Article number
Type of installation
Luminous flux factor
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671629.75X.Y
Wall (surface), Ceiling (surface)
25 m
flat hood
1 x T16 (T5) 8 W
•
•
•
•
L 344, B 144, H 78
671630.75X.Y
Wall (surface), Ceiling (surface)
21 m
high hood
1 x T16 (T5) 8 W
•
•
•
•
L 344, B 144, H 148
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance.
Spacing table 671629.752
Wire guard for wall luminaires 981168.002 L 540, B 375, H 185
Lamp luminous flux:
Accessories | Wall extension Steel bracket, white powder-coated Wall extension 981485.002
L 374, B 147, H 75
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
Mains: 450 lm, Emergency: 450 lm The following values are indicated in m h
a
b
2.5
8.7
3.8 10.8
c
4.3
d
3.0
9.0
4.0 10.7
4.4
3.5
10.2
4.0 11.2
4.5
4.0
10.1
4.0 11.8
4.4
Spacing table 671630.752
Lamp luminous flux: LP 500 mm
Mains: 450 lm, Emergency: 450 lm The following values are indicated in m
Mounting kit for chains/cable suspensions 981583.002
192
h
a
b
2.5
8.0
3.3 10.0
c
4.2
d
3.0
8.9
3.3 11.1
4.3
3.5
9.0
3.3 11.7
4.3
4.0
8.9
3.3 11.1
4.2
For connecting diagrams, see pages 119 - 121 | Article number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
Emergency Lighting | Luminaires for central emergency power supply Series: Universal 4 LED Type of protection: IP 54 Protection class: II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 21 m, 25 m For escape route identification Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: plastic (polycarbonate) transparent, prismatic, motif foil included. LED included. Ballast: EB 21 m/25 m
Available colour (X): 2 = white
Wall (surface), Ceiling (surface) (high hood) opal
Wall (surface), Ceiling (surface) (flat hood) tranparent, prismatic
H
H L
5x11
L
B
15
148,5 110
5x11 50 144
112,5
B
15
148,5 110 50 144
112,5
250 344
250 344
Dimensions
Viewing distance
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SingleControl (.81)
DuoControl (.82)
Wall (surface)
25 m
flat hood
1 x LED 4,5 W
•
•
•
•
L 344, B 144, H 78
Wall (surface), Ceiling (surface)
21 m
high hood
1 x LED 4,5 W
•
•
•
•
L 344, B 144, H 148
Article number
Type of installation
671793.00X.Y 671820.00X.Y
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Accessories | Wall extension Steel bracket, white powder-coated Wall extension 981485.002
L 374, B 147, H 75
Accessories | Pendant tube Suspension tube Ø 10 mm, chrome, with canopy: white, powder-coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube. Pendant tube 90-4164.002
LP 500 mm
Mounting kit for chains/cable suspensions 981583.002
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
193
Emergency Lighting | Luminaires for central emergency power supply LCSâ&#x20AC;&#x2018;Z Type of protection: IP 40 - Extremely flat housing, architecturally attractive design - Reflector inside - Lamp replacement without tools - Easy to install - Large viewing distance - Easy to install
Wall (surface), Ceiling (surface)
194
Wall (surface)
Emergency Lighting | Luminaires for central emergency power supply Series: LCS‑Z Type of protection: IP 40 Protection class: II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 35 m For escape route identification (only wall installation) or escape route illumination Base and reflector: plastic (polycarbonate); refractor: plastic (PMMA) transparent, 3 foils for escape route identification included. Ballast: EB Available colour (X): 2 = white
35 m
Wall (surface)
Wall (surface)
H
B
L
16
202
16
80 174
18
250 371
250 371
Article number
Type of installation
671774.75X.Y
Wall (surface)
671776.75X.Y
Wall (surface), Ceiling (surface)
Planning guide: Escape route illumination in accordance with EN 1838
Viewing distance
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
35 m
1 x T16 (T5) 8 W
•
•
•
•
L 398, B 62, H 202
-
1 x T16 (T5) 8 W
•
•
•
•
L 398, B 62, H 202
Spacing table 671776.752
Lamp luminous flux:
a b
Ø5
398
80 174
18
B
L
Ø5
398
202
H
c
d
h
E = 1 lx along the centre line
Mains: 400 lm, Emergency: 400 lm The following values are indicated in m h
a
2.5
11.1
b
c
3.0
12.1 4.6 10.4 4.6
3.5
12.8 4.8 10.9 4.8
4.0
13.2 4.6 11.2 4.6
4.5 9.7
d 4.5
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
195
Emergency Lighting | Luminaires for central emergency power supply Varioplast I Type of protection: IP 54 - Ultraflat design - IP 54 type of protection - dustproof and protected against water spray - Installation-friendly construction: folding mounting plate with lampholder and ballast - Shockproof verison - Compact design - Multi-purpose applications
Wall (surface), Ceiling (surface)
196
Wall (surface)
Emergency Lighting | Luminaires for central emergency power supply Series: Varioplast I Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 24 m For escape route identification (only in case of wall installation) or escape route illumination Base: plastic (polycarbonate); refractor: plastic (polycarbonate) transparent, prismatic, 3 foils for escape route identification included. Ballast: EB Available colours (X): 2 = white, 3 = black
24 m
Wall (surface)
Ceiling (surface)
H
H
B
B
L
6
320 288
16
148
L
30
154 80
16
6
16
116 186
27
115
148
320 288
30
16
116 186
27
5x8
154 80
115
5x8
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x TC-EL 11 W
•
•
•
•
L 320, B 80, H 186
24 m
1 x T16 (T5) 6 W
•
•
•
•
L 320, B 80, H 186
-
1 x TC-EL 11 W
•
•
•
•
L 320, B 80, H 186
-
1 x T16 (T5) 6 W
•
•
•
•
L 320, B 80, H 186
Article number
Type of installation
Viewing distance
671248.91X.Y
Wall (surface)
24 m
671291.75X.Y
Wall (surface)
671247.91X.Y
Wall (surface), Ceiling (surface)
671290.75X.Y
Wall (surface), Ceiling (surface)
Lamp/Wattage
Accessories | Wire guard Ball impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13 Wire guard and bracket: steel, white, powder-coated. Wire guard mounted with screws, can be opened for luminaire maintenance. Wire guard for wall luminaires 981168.002 L 540, B 375, H 185 Accessories | Set of screws with special anti-theft key 90-4013.002 white 90-4013.003 black Accessories | Wire guard, varnished 22125.002 L 314, B 180, H 49 22125.003 L 314, B 180, H 49 Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
white black Spacing table 671247.91X
Spacing table 671290.75X
Lamp luminous flux:
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
Mains: 300 lm, Emergency: 300 lm
The following values are indicated in m
The following values are indicated in m
h
a
2.5
10.8
b
c
d
h
a
b
c
d
4.6 13.0
5.4
2.5
7.5
3.2
8.7
3.6
3.0
11.9
4.9 13.8
5.8
3.0
8.2
3.3
9.5
3.7
3.5
12.9
5.2 14.5
6.0
3.5
8.8
3.4 10.2
3.7
4.0
13.5
5.4 14.3
6.2
4.0
8.7
3.4
3.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
9.5
197
Emergency Lighting | Luminaires for central emergency power supply Turia Z Type of protection: IP 30 - Wide luminaire spacing for escape route illumination - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install - Compact design - Inconspicuous design - The self-contained module containing the battery can easily be installed and removed through the ceiling cutout
Ceiling (recessed)
198
Emergency Lighting | Luminaires for central emergency power supply Series: Turia Z Type of protection: IP 30 Protection class: I with .Y, II without .Y Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 15-35 mm For escape route illumination Housing: die-cast aluminium: cover ring: plastic; EB in separate ballast box with connection cable. LED included. Ballast: EB Available colour (X): 2 = white
Ceiling (recessed)
HE H
DA D
Ø50
Ø42
Article number
Type of installation
Lamp/Wattage
671919.00X.Y
Ceiling (recessed)
1 x LED 2 W
Planning guide: Escape route illumination in accordance with EN 1838
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
•
•
•
•
Dimensions
D 50, H 2, DA 42, HE 45
Step 1
Step 2
Step 3
Step 4
Lamp luminous flux:
a b
Spacing table 671919.002
Control 1 (.71)
c
d
h
E = 1 lx along the centre line
Mains: 148 lm, Emergency: 148 lm The following values are indicated in m h
a
b
c
d
2.5
7.3
3.0
7.3
3.0
3.0
8.2
3.4
8.2
3.4
3.5
8.9
3.6
8.9
3.6
4.0
9.5
3.7
9.5
3.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
199
Emergency Lighting | Luminaires for central emergency power supply Edo Type of protection: IP 20 - Wide luminaire spacing for escape route illumination - Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology) - Top quality LED technology
Example
- Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install - Compact design - Inconspicuous design
+ + =
Edo 4
200
Edo 5
Edo 1 Installation in existing luminiares
Edo 2 Installation in metal ceilings
Emergency Lighting | Luminaires for central emergency power supply Series: Edo Type of protection: IP 30 Protection class: I with .Y, II without .Y Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 1-8 mm (Edo 1 and Edo 2) Ceiling thickness: 15-35 mm (Edo 4 and Edo 5) For escape route illumination Housing: die-cast aluminium; cover ring: plastic (only Edo 4 + 5), separate ballast box with connecting cable. LED included. Ballast: EB Available colour (X): 2 = white (Edo 4 and Edo 5) 4 = aluminium (Edo 1 and Edo 2)
Edo 1 Retrofitting kit
Edo 2 Retrofitting kit
Ceiling (recessed) Edo 4
LA L
D
D
HE
DA
DA
HE
HE
HE
H
H
DA D
Ø50
Article number
Ceiling (recessed) Edo 5
H
BA B
Ø40
Ø50
H
Ø40
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x LED 2 W
•
•
•
•
D 22, H 8, DA 10.5, HE 15
Edo 2
1 x LED 2 W
•
•
•
•
D 27, H 1, DA 22, HE 23
Ceiling (recessed)
Edo 4
1 x LED 2 W
•
•
•
•
D 50, H 3, DA 40, HE 45
Ceiling (recessed)
Edo 5
1 x LED 2 W
•
•
•
•
L 50, B 50, H 3, DA 40, HE 45
Type of installation
Type
Lamp/Wattage
671950.00X.Y
Retrofitting kit
Edo 1
671951.00X.Y
Installation in metal ceilings
671936.00X 671937.00X
Edo 1
Accessories | Fixing bracket for Edo 1 Bracket for fixing Edo 1 into recessed luminiares such as downlights or louvre luminaires. Bracket is to be installed in existing reflector or louvre. Fixing bracket for Edo 1 981778.000
Planning guide: Escape route illumination in accordance with EN 1838
Table applies to all Edo series luminaires
Edo 2
Lamp luminous flux:
a b
Spacing table 671950.00X
c
d
h
E = 1 lx along the centre line
Mains: 109 lm, Emergency: 109 lm The following values are indicated in m h
a
b
c
d
2.5
7.7
3.0
7.7
3.0
3.0
8.5
3.2
8.5
3.2
3.5
8.9
3.2
8.9
3.2
4.0
9.1
3.2
9.1
3.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
201
Emergency Lighting | Luminaires for central emergency power supply Lucio Type of protection: IP 40 - Wide luminaire spacing for escape route illumination - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Compact design - Easy to install - Multi-purpose applications, either as recessed or surface mounted ceiling luminaire
Ceiling (surface)
202
Ceiling (recessed)
Emergency Lighting | Luminaires for central emergency power supply Series: Lucio Type of protection: IP 40 Protection class: II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 5-25 mm For escape route illumination Housing: plastic. Accessories for recessed and surface ceiling installation included. LED included. Ballast: EB Available colour (X): 2 = white
Ceiling (surface)
Ceiling (recessed)
D
HE
104
H
DA D
H
25
8)
(7
Ø4,2 Ø4,2
51 73,5
Ø16
Ø120
Ø105
59 Ø120
Article number
Type of installation
Ceiling (surface), Ceiling (recessed)
671916.00X.Y
Planning guide: Escape route illumination in accordance with EN 1838
Control 1 (.71)
1 x LED 3 W
-
TWINControl (.72)
-
SINGLEControl (.81)
-
DUOControl (.82)
-
Dimensions
Surface installation: D 120, H 45 Recessed installation: D 120, H 3, DA 105, HE 42
Spacing table 671916.002
Lamp luminous flux:
a b
Lamp/Wattage
c
d
h
E = 1 lx along the centre line
Mains: 56 lm, Emergency: 56 lm The following values are indicated in m h
a
b
c
d
2.5
5.2
2.1
5.2
2.1
3.0
5.7
2.0
5.7
2.0
3.5
6.0
1.7
6.0
1.7
4.0
5.9
1.0
5.9
1.0
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
203
Emergency Lighting | Luminaires for central emergency power supply Centryxx Type of protection: IP 40 - Wide luminaire spacing for escape route illumination - Design matches modern architectural styles - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install
Ceiling (surface)
204
Ceiling (recessed), square
Ceiling (recessed), round
Emergency Lighting | Luminaires for central emergency power supply Series: Centryxx Type of protection: IP 20 (Wall (surface)), IP 40 (Ceiling (recessed)) Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: die-cast aluminium, powder-coated; transparent plastic diffuser for optimum illumination of escape route. Ballast: EB Available colour (X): 2 = white
Ceiling (surface)
Ceiling (recessed), square
Ceiling (recessed), round
B
B
HE
HE
L
H
DA L
H
DA D
H
51
180
Ø5
Ø200
90
Ø185
Ø200
Ø185
Ø5
90 180
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x LED 3 W
-
-
-
•
L 180, B 180, H 27
square
1 x LED 3 W
-
-
-
•
L 220, B 220, H 3 DA 185, HE 73
round
1 x LED 3 W
-
-
-
•
D 200, H 3 DA 185, HE 73
Type of installation
671841.00X.Y
Ceiling (surface)
square
671839.00X.Y
Ceiling (recessed)
671837.00X.Y
Ceiling (recessed)
Planning guide: Escape route illumination in accordance with EN 1838
Type
Lamp/Wattage
Table applies to all Centryxx series luminaires
Spacing table 671841.002
Lamp luminous flux:
a b
c
d
h
E = 1 lx along the centre line
Dimensions
Control 1 (.71)
Article number
Mains: 180 lm, Emergency: 180 lm The following values are indicated in m h
a
b
2.5
3.4
0.9 12.6
c
5.6
d
3.0
3.0
0.8 14.2
6.4
3.5
2.6
0.7 16.1
7.1
4.0
2.4
0.0 10.5
0.0
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
205
Emergency Lighting | Luminaires for central emergency power supply Solyxx Type of protection: IP 20 - Wide luminaire spacing for escape route illumination - Subdued design - Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology) - Top quality LED technology - Specially calculated thermal management - Very low maintenance costs - LED service life: approx. 50,000 hours - Easy to install
Ceiling (surface)
206
Ceiling (recessed)
Emergency Lighting | Luminaires for central emergency power supply Series: Solyxx Type of protection: IP 20 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 1-25 mm For escape route illumination Housing and anti-glare shield: aluminium, white; for surface installation: white plastic housing; plastic diffuser: prismatic. Ballast: EB Available colour (X): 2 = white
Ceiling (surface)
Ceiling (recessed)
LA L
L
HE
H
H
BA B
B
118 93
120 108 25 94 118
70
120
Ø6 18
108
15
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x LED 3 W
-
-
•
-
L 118, B 118, H 58
1 x LED 3 W
-
-
•
•
L 120, B 120, H 5 LA 108 x BA 108, HE 80
Type of installation
Lamp/Wattage
671854.00X.Y
Ceiling (surface)
671835.00X.Y
Ceiling (recessed)
Planning guide: Escape route illumination in accordance with EN 1838
Spacing table 671854.002 und 671835.002
Lamp luminous flux:
a b
Dimensions
Control 1 (.71)
Article number
c
d
h
E = 1 lx along the centre line
Mains: 178 lm, Emergency: 178 lm The following values are indicated in m h
a
b
c
d
2.5
8.6
3.7
5.2
2.1
3.0
9.6
3.9
5.6
2.1
3.5
10.5
4.3
5.9
2.1
4.0
11.2
4.6
6.2
2.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
207
Emergency Lighting | Luminaires for central emergency power supply Energo TC 175 Type of protection: IP 23 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Housing made of top quality die-cast aluminium - Wide luminaire spacing for escape route illumination - Modern design - Bezel ring made of die-cast aluminium - Infinitely adjustable spring fastening system - EBs in separate ballast box - Modular recessed luminaire with small recessed depth - Easy to install - For ceiling thicknesses of 1-40 mm
Ceiling (recessed)
208
Emergency Lighting | Luminaires for central emergency power supply Series: Energo TC 175 Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 1-40 mm For escape route illumination Modular design: A bezel ring must always be ordered for each basic luminaire! Recess and bezel ring: die-cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑ nium, highly polished anodised finish; ceiling installation with spring system. EB in separate ballast box with connecting cable L 400 mm in flexible hose, 5-pole double terminal for through-wiring. Ballast: EB Available colour (X) Basic luminaire: 4 = silver metallic
Ceiling (recessed)
HE H
DA D
Ø188
Ø175
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x TC-DEL 13 W
•
•
•
•
D 188, H 4, DA 175, HE 100
2/1
2 x TC-DEL 13 W
•
•
•
•
D 188, H 4, DA 175, HE 100
1/1
1 x TC-DEL 18 W
•
•
•
•
D 188, H 4, DA 175, HE 100
2/1
2 x TC-DEL 18 W
•
•
•
•
D 188, H 4, DA 175, HE 100
Type of installation
671877.92X.Y
Ceiling (recessed)
1/1
671879.92X.Y
Ceiling (recessed)
671878.96X.Y
Ceiling (recessed)
671880.96X.Y
Ceiling (recessed)
Moulded housing 981656.000
Dimensions
Control 1 (.71)
Article number
Lamps Mains/ Emergency
Moulded housing
Lamp/Wattage
L 500, B 250, H 160 mm
Panel mounting frame 98102.002/176 Panel mounting frame
Dimensions 285 x 285 mm
Bezel rings with safety glass, D 194 mm, H 9 mm 981653.002 Safety glass, transparent 981653.004 Safety glass, transparent Bezel rings without safety glass, D 194 mm, H 9 mm 981653.102 981653.104
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671877.92X und 671879.92X
Spacing table 671878.96X und 671880.96X
Lamp luminous flux:
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
2.5
7.7
2.8
7.7
2.8
2.5
7.5
2.9
7.5
2.9
3.0
8.1
2.9
8.1
2.9
3.0
8.1
3.1
8.1
3.1
3.5
8.4
2.8
8.4
2.8
3.5
8.5
3.0
8.5
3.0
4.0
8.3
2.7
8.3
2.7
4.0
8.7
3.0
8.7
3.0
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
209
Emergency Lighting | Luminaires for central emergency power supply Energo TC 210 Type of protection: IP 23 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Housing made of top quality die-cast aluminium - Wide luminaire spacing for escape route illumination - Modern design - Bezel ring made of die-cast aluminium - Infinitely adjustable spring fastening system - EBs in separate ballast box - Modular recessed luminaire with small recessed depth - Easy to install - For ceiling thicknesses of 1-40 mm
Ceiling (recessed)
210
Emergency Lighting | Luminaires for central emergency power supply Series: Energo TC 210 Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 1-40 mm For escape route illumination Modular design: A bezel ring must always be ordered for each basic luminaire! Recess and bezel ring: die-cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑ nium, highly polished anodised finish; ceiling installation with spring system. EB in separate ballast box with connecting cable L 400 mm in flexible hose, 5-pole double terminal for through-wiring. Ballast: EB Available colour (X) Basic luminaire: 4 = silver metallic
Ceiling (recessed)
HE H
DA D
Ø220
Ø210
Article number
Type of installation
671883.83X.Y
Ceiling (recessed)
1/1
671884.83X.Y
Ceiling (recessed)
2/1
Moulded housing 981662.000
Lamps Mains/ Emergency
Moulded housing
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x TC-TEL 32 W
•
•
•
•
D 220, H 4, DA 210, HE 120
2 x TC-TEL 32 W
•
•
•
•
D 220, H 4, DA 210, HE 120
Lamp/Wattage
L 450, B 300, H 200 mm
Panel mounting frame 98102.002/215 Panel mounting frame
Dimensions 285 x 285 mm
Bezel rings with decorative attachment, D 250 mm, H 38 mm 981660.002 Decorative glass, transparent 981660.004 Decorative glass, transparent Bezel rings with safety glass, D 227 mm, H 9 mm 981659.002 Safety glass, transparent 981659.004 Safety glass, transparent
Planning guide: Escape route illumination in accordance with EN 1838
Lamp luminous flux:
a b
Spacing table 671883.83X und 671884.83X
c
d
h
E = 1 lx along the centre line
Mains: 1800 lm, Emergency: 1800 lm The following values are indicated in m h
a
b
c
d
2.5
9.4
3.8
9.4
3.8
3.0
10.3
4.1 10.3
4.1
3.5
11.0
4.1 11.0
4.1
4.0
11.5
4.1 11.5
4.1
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
211
Emergency Lighting | Luminaires for central emergency power supply Andho TC Flat Type of protection: IP 23 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Housing made of top quality die-cast aluminium - Top quality reflector made of aluminium, highly polished anodised finish
Ceiling (surface)
212
Emergency Lighting | Luminaires for central emergency power supply Series: Andho TC Flat Type of protection: IP 23 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: aluminium extrusion profile, powder-coated; cover ring and ceiling base: die-cast aluminium, powder-coated, with bayonet fixing; reflector: aluminium, highly polished anodised finish; EB incorporated, 5-pole double terminal for throughwiring. Ballast: EB Available colours (X): 2 = white, 4 = silver metallic
Ceiling (surface)
D
H
Ø230 Ø7 178
45 178
Article number
Type of installation
671885.82X.Y
Ceiling (surface)
2/2
671886.84X.Y
Ceiling (surface)
2/2
671887.83X.Y
Ceiling (surface)
2/2
Accessories 981678.002 981678.004
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
2 x TC-TEL 13 W
•
•
•
•
D 230, H 140
2 x TC-TEL 18 W
•
•
•
•
D 230, H 140
2 x TC-TEL 26 W
•
•
•
•
D 230, H 140
Lamp/Wattage
Suspension cable (2m) with 5-pole power supply cable (IP 23) Suspension cable (2m) with 5-pole power supply cable (IP 23)
Planning guide: Escape route illumination in accordance with EN 1838 a b
Lamps Mains/ Emergency
c
d
h
E = 1 lx along the centre line
Spacing table 671885.82X
Spacing table 671886.84X
Spacing table 671887.83X
Luminaire luminous flux:
Luminaire luminous flux:
Luminaire luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
Mains: 2400 lm, Emergency: 2400 lm
Mains: 3600 lm, Emergency: 3600 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
10.5
4.7 10.2
4.5
2.5
10.5
b
c
b
c
d
h
a
4.7 10.2
4.5
2.5
10.5
4.7 10.2
b
c
4.5
d
3.0
12.7
5.4 12.2
5.2
3.0
12.7
5.6 12.3
5.4
3.0
12.7
5.6 12.3
5.4
3.5
14.1
5.8 13.4
5.6
3.5
14.8
6.3 14.2
6.0
3.5
14.8
6.5 14.3
6.3
4.0
15.2
6.4 14.4
6.1
4.0
16.1
6.9 15.4
6.4
4.0
16.9
7.5 16.4
7.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
213
Emergency Lighting | Luminaires for central emergency power supply Andho TC Flat IP 65 Type of protection: IP 65 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Housing made of top quality die-cast aluminium - Top quality reflector made of aluminium, highly polished anodised finish
Ceiling (surface)
214
Emergency Lighting | Luminaires for central emergency power supply Series: Andho TC Flat IP 65 Type of protection: IP 65 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: aluminium extrusion profile, powder-coated; ceiling base: die-cast aluminium, powder-coated, with bayonet fixing; cover ring: die-cast aluminium, powder-coated, screwed on the luminaire; safety glass, transparent; reflector: aluminium, highly polished anodised finish; EB incorporated, 5-pole double terminal for through-wiring. Ballast: EB Available colours (X): 2 = white, 4 = silver metallic
Ceiling (surface)
D
H
Ø230 Ø7 178
45 178
Article number
Type of installation
671888.82X.Y
Ceiling (surface)
2/2
671889.84X.Y
Ceiling (surface)
2/2
671890.83X.Y
Ceiling (surface)
2/2
Accessories 981678.002 981678.004
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
2 x TC-TEL 13 W
•
•
•
•
D 230, H 148
2 x TC-TEL 18 W
•
•
•
•
D 230, H 148
2 x TC-TEL 26 W
•
•
•
•
D 230, H 148
Lamp/Wattage
Suspension cable (2m) with 5-pole power supply cable (IP 23) Suspension cable (2m) with 5-pole power supply cable (IP 23)
Planning guide: Escape route illumination in accordance with EN 1838 a b
Lamps Mains/ Emergency
c
d
h
E = 1 lx along the centre line
Spacing table 671888.82X
Spacing table 671889.84X
Spacing table 671890.83X
Luminaire luminous flux:
Luminaire luminous flux:
Luminaire luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
Mains: 2400 lm, Emergency: 2400 lm
Mains: 3600 lm, Emergency: 3600 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
b
c
d
h
a
b
c
d
h
a
b
c
d
2.5
9.9
4.5
9.4
4.1
2.5
9.9
4.5
9.4
4.1
2.5
9.9
4.5
9.4
4.1
3.0
11.6
4.9 11.0
4.8
3.0
11.9
5.2 11.3
4.9
3.0
11.9
5.4 11.3
4.9
3.5
12.7
5.3 12.1
5.1
3.5
13.5
5.8 12.8
5.6
3.5
13.9
6.3 13.2
5.8
4.0
13.8
5.9 13.2
5.7
4.0
14.6
6.4 13.8
5.9
4.0
15.8
6.6 15.0
6.4
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
215
Emergency Lighting | Luminaires for central emergency power supply Arelo速 Type of protection: IP 20 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Recessed ring made of die-cast aluminium - Top quality reflector made of aluminium, highly polished anodised finish - Wide beam light distribution - All versions with EB in separate ballast box - Simple spring system for installation without tools
Ceiling (recessed)
216
Emergency Lighting | Luminaires for central emergency power supply Series: Arelo® Type of protection: IP 20 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 1-25 mm For escape route illumination Mounting frame: die-cast aluminium, powder-coated; bracket: galvanised sheet steel; reflector: aluminium, highly polished anodised finish, separate ballast box; length of cable between luminaire and ballast box: 400 mm; suitable for through-wiring. Ballast: EB Available colour (X): 2 = white
Ceiling (recessed)
HE H
DA D
Ø218
Ø200
Dimensions
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
1 x TC-DEL 18 W
•
•
•
•
D 218, H 3, DA 200, HE 106
2/2
2 x TC-DEL 18 W
•
•
•
•
D 218, H 3, DA 200, HE 106
Ceiling (recessed)
1/1
1 x TC-DEL 26 W
•
•
•
•
D 218, H 3, DA 200, HE 106
Ceiling (recessed)
2/2
2 x TC-DEL 26 W
•
•
•
•
D 218, H 3, DA 200, HE 106
Article number
Type of installation
Lamps Mains/ Emergency
671869.96X.Y
Ceiling (recessed)
1/1
671871.96X.Y
Ceiling (recessed)
671870.95X.Y 671872.95X.Y
Lamp/Wattage
Cover screens with spring fastening IP 43 981734.000 Safety glass, transparent
Spacing table 671872.952
Luminaire luminous flux: Mains: 3600 lm, Emergency: 3600 lm The following values are indicated in m
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
h
a
2.5
10.4
4.7 10.6
b
c
4.9
d
3.0
12.4
5.6 12.7
5.8
3.5
14.4
6.3 14.8
6.8
4.0
15.8
6.9 16.9
7.5
Spacing table 671869.962
Spacing table 671870.952
Spacing table 671871.962
Lamp luminous flux:
Lamp luminous flux:
Luminaire luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
Mains: 1800 lm, Emergency: 1800 lm
Mains: 2400 lm, Emergency: 2400 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
10.4
4.5 10.8
4.9
2.5
11.6
b
c
b
c
d
h
a
4.9 11.3
5.1
2.5
10.3
4.7 10.6
b
c
4.9
d
3.0
11.8
4.9 12.4
5.4
3.0
12.8
5.6 13.1
5.8
3.0
12.3
5.4 12.7
5.8
3.5
13.0
5.3 13.8
6.0
3.5
14.2
6.0 14.6
6.5
3.5
13.7
6.0 14.8
6.5
4.0
14.0
5.9 15.1
6.4
4.0
15.5
6.4 16.0
6.9
4.0
15.0
6.6 16.2
7.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
217
Emergency Lighting | Luminaires for central emergency power supply Mondana Type of protection: IP 65 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Diffuser: glass or PE sintered glass (polyethylene), shockproof - IP 65 provides safe protection against humidity - dust and insects cannot penetrate the luminaire - Goreâ&#x201E;˘ diaphragm valve for pressure equalisation and prevention of condensation - Easy to install - Wide range of applications thanks to various types of installation - Lamp replacement without tools
Wall (surface), Ceiling (surface)
218
Semi-recessed installation (wall, ceiling)
Emergency Lighting | Luminaires for central emergency power supply Series: Mondana Type of protection: IP 65 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Ceiling thickness: 10-30 mm For escape route illumination Base: plastic (polycarbonate), microstructure coating; diffuser: plastic (polyethylene) or mouth-blown opal glass, satin finish; diffuser fastening: screwneck; housing for semi-recessed installation in walls and ceilings: powder-coated aluminium. Standard Gore™ Protective Vents diaphragm valve for reduction of condensation. Ballast: EB Available colours (X): 2 = white, 4 = silver metallic Semi-recessed installation (wall, ceiling) DA 310 D
Semi-recessed installation (wall, ceiling) DA 390
H
D
Wall (surface), Ceiling (surface) D 500 and D 550
Wall (surface), Ceiling (surface) D 390
H H
D
DA
H
D
DA
HE
HE
Ø300
Ø380
140
65 Ø310
Ø390
70
70 Ø5,5
Ø5,5
13 170
Article number
Type of installation
Type
Lamps Mains/ Emergency
5 242,5
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671801.00X.Y
Semi-recessed instal‑ lation (wall, ceiling)
Glass
1/1
1 x T16-R 22 W
•
•
•
•
D 390, H 57 DA 310, HE 96
671800.80X.Y
Semi-recessed instal‑ lation (wall, ceiling)
Glass
2/2
1 x T16-R 22 W + 1 x T16-R 40 W
•
•
•
•
D 500, H 78 DA 390, HE 100
671799.80X.Y
Semi-recessed instal‑ lation (wall, ceiling)
PE
2/2
1 x T16-R 22 W + 1 x T16-R 40 W
•
•
•
•
D 550, H 85 DA 390, HE 100
671781.00X.Y
Wall (surface), Ceiling (surface)
Glass
1/1
1 x T16-R 22 W
•
•
•
•
D 390, H 101
671790.80X.Y
Wall (surface), Ceiling (surface)
Glass
2/2
1 x T16-R 22 W + 1 x T16-R 40 W
•
•
•
•
D 500, H 128
671791.80X.Y
Wall (surface), Ceiling (surface)
PE
2/2
1 x T16-R 22 W + 1 x T16-R 40 W
•
•
•
•
D 550, H 135
Accessories | Moulded housing Moulded housing 981630.002 981631.002 981631.002
for Mondana D 390 for Mondana D 500 for Mondana D 550
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671799.80X
Spacing table 671791.80X
Luminaire luminous flux:
Luminaire luminous flux:
Mains: 5000 lm, Emergency: 5000 lm
Mains: 5000 lm, Emergency: 5000 lm
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
14.5
5.8 14.5
5.8
2.5
11.6
5.8 11.5
5.8
3.0
17.4
7.0 17.4
7.0
3.0
16.9
7.0 16.9
7.0
3.5
18.6
7.5 18.6
7.5
3.5
19.5
7.8 19.5
7.8
4.0
19.6
7.8 19.6
7.8
4.0
20.5
8.2 20.5
8.2
b
c
b
c
d
Spacing table 671801.00X und 671981.00X
Spacing table 671800.80X
Spacing table 671790.80X
Lamp luminous flux:
Luminaire luminous flux:
Luminaire luminous flux:
Mains: 1800 lm, Emergency: 1800 lm
Mains: 5000 lm, Emergency: 5000 lm
Mains: 5000 lm, Emergency: 5000 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
11.9
4.7 11.9
4.7
2.5
14.5
b
c
b
c
d
h
a
5.8 14.5
5.8
2.5
14.5
5.8 14.5
b
c
5.8
d
3.0
12.7
4.9 12.7
4.9
3.0
17.4
7.0 17.4
7.0
3.0
17.4
7.0 17.4
7.0
3.5
13.4
5.1 13.4
5.1
3.5
18.6
7.5 18.6
7.5
3.5
18.6
7.5 18.6
7.5
4.0
14.0
5.3 14.0
5.3
4.0
19.6
7.8 19.6
7.8
4.0
19.6
7.8 19.6
7.8
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
219
Emergency Lighting | Luminaires for central emergency power supply Flat Polymero速 Type of protection: IP 40 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Compact design - Extremely high Light Output Ratio of up to 81% - Easy to install - Low maintenance costs - Wide range of applications thanks to various types of installation
Wall (surface), Ceiling (surface)
220
Emergency Lighting | Luminaires for central emergency power supply Serie: Flat Polymero® Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Base: powder-coated metal; diffuser: plastic (PMMA), opal, or plastic (polycarbonate), shockproof. Diffuser fastening with patented system (push system). Ballast: EB Available colour (X): 2 = white
Wall (surface), Ceiling (surface)
D
H
Ø324
100
30
50
25
Ø5,5 173
Article number
Type of installation
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671952.00X.1.Y
Wall (surface), Ceiling (surface)
PMMA
1 x T16-R 22 W
•
•
•
•
D 360, H 100
671952.00X.2.Y
Wall (surface), Ceiling (surface)
PC
1 x T16-R 22 W
•
•
•
•
D 360, H 100
Planning guide: Escape route illumination in accordance with EN 1838
Lamp luminous flux:
a b
Spacing table 671952.002.1 und 671952.002.2
c
d
h
E = 1 lx along the centre line
Mains: 1800 lm, Emergency: 1800 lm The following values are indicated in m h
a
2.5
13.9
5.3 13.9
b
c
5.3
d
3.0
14.8
5.8 14.8
5.8
3.5
15.7
6.0 15.7
6.0
4.0
16.4
6.4 16.4
6.4
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
221
Emergency Lighting | Luminaires for central emergency power supply Flat Polymero速 PMMA Flat Polymero速 PC Type of protection: IP 43 (Ceiling (surface)), IP 44 (Wall (surface))
- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Architecturally attractive design - Compact design - Easy to install - With spring system - for opening the luminaire without tools - for gently detaching and positioning the diffuser
Wall (surface), Ceiling (surface)
222
Emergency Lighting | Luminaires for central emergency power supply Series: Flat Polymero® PMMA and PC Type of protection: IP 43 Ceiling (surface), IP 44 Wall (surface) Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Base: plastic; diffuser: plastic (PMMA) or plastic (polycarbonate), opal; diffuser fastening: spring system. Ballast: EB Available colour (X): 2 = white
Wall (surface), Ceiling (surface)
D
Ø H
Ø305 Ø262
Ø5
100
50 205
Article number
Type of installation
Type
Wall (surface), Ceiling (surface) Wall (surface), Ceiling (surface) Wall (surface), Ceiling (surface) Wall (surface), Ceiling (surface)
671958.96X.1.Y 671958.96X.2.Y 671959.95X.1.Y 671959.95X.2.Y
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
PMMA
1 x TC-DEL 18 W
•
•
•
•
D 305, H 115
PC
1 x TC-DEL 18 W
•
•
•
•
D 305, H 115
PMMA
1 x TC-DEL 26 W
•
•
•
•
D 305, H 115
PC
1 x TC-DEL 26 W
•
•
•
•
D 305, H 115
Accessories | Decorative rings, metal, for series: Flat Polymero® PMMA and PC Available colours: Decorative ring, painted (Z): 2 = white, 61 = ultramarine blue, 76 = rape yellow, 82 = ruby red, 9 = light grey. Other RAL colours available on request
Spacing table 671959.952.2
Available colours: Decorative ring, metallised (Z): 4 = chrome, 42 = nickel, matt, 5 = brass
Mains: 1800 lm, Emergency: 1800 lm
Lamp luminous flux: The following values are indicated in m
Decorative rings, metal Decorative ring D 325 mm, for diffuser D 305 mm 981224.00Z D 325, H 10
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
h
a
2.5
13.0
5.2 13.0
b
c
5.2
d
3.0
13.1
5.6 13.1
5.6
3.5
14.3
5.8 14.3
5.8
4.0
15.1
6.1 15.1
6.1
Spacing table 671958.962.1
Spacing table 671958.962.2
Spacing table 671959.952.1
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
Mains: 1200 lm, Emergency: 1200 lm
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
10.8
4.6 10.8
4.6
2.5
10.8
b
c
d
h
a
4.6 10.8
4.6
2.5
13.0
5.2 13.0
5.2
b
c
b
c
d
3.0
12.1
4.8 12.1
4.8
3.0
12.1
4.8 12.1
4.8
3.0
13.1
5.6 13.1
5.6
3.5
12.8
5.0 12.8
5.0
3.5
12.8
5.0 12.8
5.0
3.5
14.3
5.8 14.3
5.8
4.0
12.8
5.2 12.8
5.2
4.0
12.8
5.2 12.8
5.2
4.0
15.1
6.1 15.1
6.1
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
223
Emergency Lighting | Luminaires for central emergency power supply Flat Basic Type of protection: IP 43 (Ceiling (surface)), IP 44 (Wall (surface)) - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - A design that fits well with modern architecture - Low maintenance costs - Compact design - Easy to install - Spring system or bayonet fixing allow for smooth attachment and removal of diffuser - without tools
Wall (surface), Ceiling (surface)
224
Emergency Lighting | Luminaires for central emergency power supply Series: Flat Basic Type of protection: IP 43 Ceiling (surface), IP 44 Wall (surface) Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Base: plastic, white; diffuser: mouth-blown opal glass, satin finish; glass fastening: spring system or bayonet fixing. Ballast: EB Available colour (X): 2 = white
Wall (surface), Ceiling (surface) D 300
Wall (surface), Ceiling (surface) D 370
D
Wall (surface), Ceiling (surface) D 420
D
Ø
D
Ø H
Ø H
370 Ø262
Ø5
H
Ø280 52
420 Ø262
Ø5
26
D
Ø H
300 Ø201
Wall (surface), Ceiling (surface) D 500
1
Ø5 100
100
3x120°
48
R76
Ø500
Ø5 2
170
50 205
Article number
Type of installation
50 205
Lamp/Wattage
58 Ø380
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671953.92X.Y
Wall (surface), Ceiling (surface)
1 x TC-DEL 13 W
–
–
–
–
D 300, H 106
671955.95X.Y
Wall (surface), Ceiling (surface)
1 x TC-DEL 26 W
•
•
•
•
D 370, H 118
671956.95X.Y
Wall (surface), Ceiling (surface)
1 x TC-DEL 26 W
•
•
•
•
D 420, H 124
671954.84X.Y
Wall (surface), Ceiling (surface)
1 x TC-TEL 18 W
–
–
–
–
D 300, H 106
671957.00X.Y
Wall (surface), Ceiling (surface)
1 x T16-R 55 W
•
•
•
•
D 500, H 150
Accessories | Decorative rings, metal, for series: Flat Basic Available colours decorative ring, painted (Z): 2 = white, 61 = ultramarine blue, 76 = rape yellow, 82 = ruby red, 9 = light grey. Other RAL colours available on request
Spacing table 671957.002
Spacing table 671956.952
Available colours: Decorative ring, metallised (Z): 4 = chrome, 42 = nickel, matt, 5 = brass
Lamp luminous flux:
Lamp luminous flux:
Mains: 4400 lm, Emergency: 4400 lm
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
16.5
7.3 16.5
7.3
2.5
14.3
6.1 14.3
6.1
3.0
19.2
7.9 19.2
7.9
3.0
15.4
6.5 15.4
6.5
3.5
20.2
8.4 20.2
8.4
3.5
16.0
6.9 16.0
6.9
4.0
20.7
8.8 20.7
8.8
4.0
17.0
7.3 17.0
7.3
Decorative rings, metal Decorative ring D 320 mm, for glass D 300 mm 981098.00Z D 320, H 10 Decorative ring D 390 mm, for glass D 370 mm 981129.00Z D 390, H 10 Decorative ring D 440 mm, for glass D 420 mm 981100.00Z D 440, H 10 Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
b
c
b
c
d
Spacing table 671953.922
Spacing table 671954.842
Spacing table 671955.952
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 900 lm, Emergency: 900 lm
Mains: 1200 lm, Emergency: 1200 lm
Mains: 1800 lm, Emergency: 1800 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
11.4
4.9 11.4
4.9
2.5
12.7
b
c
b
c
d
h
a
5.4 12.7
5.4
2.5
14.3
6.1 14.3
6.1
b
c
d
3.0
12.5
5.2 12.5
5.2
3.0
13.4
5.7 13.4
5.7
3.0
15.4
6.5 15.4
6.5
3.5
13.7
5.5 13.7
5.5
3.5
14.5
6.1 14.5
6.1
3.5
16.0
6.9 16.0
6.9
4.0
14.5
5.7 14.5
5.7
4.0
15.6
6.3 15.6
6.3
4.0
17.0
7.3 17.0
7.3
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
225
Emergency Lighting | Luminaires for central emergency power supply Flat Polymero速 Rechteck Type of protection: IP 40 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Design matches modern architectural styles - Very large viewing distance with motifs - Flat design - Luminaire can be opened without tools
Wall (surface)
226
Wall (surface), Ceiling (surface)
Emergency Lighting | Luminaires for central emergency power supply Series: Flat Polymero® Rechteck Type of protection: IP 40 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz Viewing distance: 50 m For escape route identification (only in case of wall installation) or escape route illumination. Base: metal, powder-coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: sash lock, plastic. Please quote symbol number when ordering escape route motifs! Ballast: EB Available colour (X): 2 = white
50 m
Wall (surface), Ceiling (surface)
H
B
L
600 530
Ø5,5
320 245
48 306
581
Article number
Type of installation
Luminous flux factor
Lamps Mains/ Emergency
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671978.75X.Y
Wall (surface), Ceiling (surface)
50 m
2/1
2 x T16 (T5) 14 W
•
•
•
•
L 600, B 320, H 75
671979.75X.Y
Wall (surface), Ceiling (surface)
50 m
2/1
2 x T16 (T5) 24 W
•
•
•
•
L 600, B 320, H 75
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671978.752
Spacing table 671979.752
Lamp luminous flux:
Lamp luminous flux:
Mains: 1350 lm, Emergency: 1350 lm
Mains: 2000 lm, Emergency: 2000 lm
The following values are indicated in m
The following values are indicated in m
h
a
2.5
11.4
d
h
a
4.9 11.4
4.9
2.5
13.6
5.6 13.6
5.6
b
c
b
c
d
3.0
12.5
5.2 12.5
5.2
3.0
13.7
6.0 13.7
6.0
3.5
13.7
5.5 13.7
5.5
3.5
14.9
6.3 14.9
6.3
4.0
14.5
5.7 14.5
5.7
4.0
16.0
6.5 16.0
6.5
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
227
Emergency Lighting | Luminaires for central emergency power supply Rounded速 extra flat Type of protection: IP 54 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Fits well with modern architecture - Housing made of top quality die-cast aluminium - Low maintenance costs - Compact design - Easy to install - Flat design - IP 54 type of protection - dustproof and protected against water spray
Wall (surface), Ceiling (surface)
228
Wall (semi-recessed)
Emergency Lighting | Luminaires for central emergency power supply Series: Rounded® extra flat Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Base: die-cast aluminium, powder-coated. Diffuser: glass, opal, mouth-blown, satin finish, or plastic (polycarbonate), opal. Ballast: EB Available colours (X): 2 = white, 31 = anthracite metallic, 4 = silver metallic Wall (surface), Ceiling (surface)
D
Wall (semi-recessed)
D
H
H
Ø237 HE
Ø258
Ø258
170
Ø235
Ø6
22
Ø6
170
75
75
80 Ø270
Article number
80 Ø270
Type of installation
Viewing distance
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671968.96X
Wall (surface), Ceiling (surface)
-
Glass
1 x TC-DEL 18 W
-
-
-
-
D 270, H 110
671970.96X
Wall (surface), Ceiling (surface)
-
PC
1 x TC-DEL 18 W
-
-
-
-
D 270, H 110
671969.95X
Wall (surface), Ceiling (surface)
-
Glass
1 x TC-DEL 26 W
-
-
-
-
D 270, H 110
671971.95X
Wall (surface), Ceiling (surface)
-
PC
1 x TC-DEL 26 W
-
-
-
-
D 270, H 110
671964.96X
Wall (semi-recessed)
-
Glass
1 x TC-DEL 18 W
-
-
-
-
D 270, H 80, HE 22
671966.96X
Wall (semi-recessed)
-
PC
1 x TC-DEL 18 W
-
-
-
-
D 270, H 80, HE 22
671965.95X
Wall (semi-recessed)
-
Glass
1 x TC-DEL 26 W
-
-
-
-
D 270, H 80, HE 22
671967.95X
Wall (semi-recessed)
-
PC
1 x TC-DEL 26 W
-
-
-
-
D 270, H 80, HE 22
Plastic moulded housing 981095.000
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671964.96X und 671966.96X
Spacing table 671965.95X, 671967.95X und 671971.95X
Spacing table 671968.96X und 671970.96X
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
Mains: 1800 lm, Emergency: 1800 lm
Mains: 1200 lm, Emergency: 1200 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
10.6
4.5 10.6
4.5
2.5
12.2
b
c
d
h
a
5.2 12.2
5.2
2.5
10.6
4.5 10.6
4.5
b
c
b
c
d
3.0
11.7
4.8 11.7
4.8
3.0
12.9
5.5 12.9
5.5
3.0
11.7
4.8 11.7
4.8
3.5
12.8
5.1 12.8
5.1
3.5
13.9
5.8 13.9
5.8
3.5
12.8
5.1 12.8
5.1
4.0
12.4
5.2 12.4
5.2
4.0
15.0
6.1 15.0
6.1
4.0
12.4
5.2 12.4
5.2
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
229
Emergency Lighting | Luminaires for central emergency power supply Alu-Lux oval Alu-Rund Type of protection: IP 54 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Modern design - Housing made of sturdy die-cast aluminium - Low maintenance costs - Compact design - Easy to install - With glass cover
Wall (surface), Ceiling (surface)
230
Wall (surface), Ceiling (surface)
Emergency Lighting | Luminaires for central emergency power supply Series: Alu-Lux oval
Series: Alu‑Rund
Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz
Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz
For escape route illumination
For escape route illumination
Base: die-cast aluminium, powdercoated. Glass: frosted inside.
Base: die-cast aluminium, powdercoated. Glass: frosted inside.
Ballast: EB
Ballast: EB
Available colours (X): 2 = white, 3 = black
Available colours (X): 2 = white, 3 = black
Wall (surface), Ceiling (surface)
Wall (surface), Ceiling (surface)
D
B
H
H L
40
285 175 165 45
45
Ø240 30
30
30
Article number
Ø5
Ø5
65
Type of installation
Type
Lamp/Wattage
15
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671963.96X
Wall (surface), Ceiling (surface)
Alu-Lux oval
1 x TC-DEL 18 W
-
-
-
-
L 280, B 160, H 140
671972.92X
Wall (surface), Ceiling (surface)
Alu-Rund
1 x TC-DEL 13 W
-
-
-
-
D 240, H 130
671973.96X
Wall (surface), Ceiling (surface)
Alu-Rund
1 x TC-DEL 18 W
-
-
-
-
D 240, H 130
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
Spacing table 671963.96X
Spacing table 671973.96X
Spacing table 671972.92X
Lamp luminous flux:
Lamp luminous flux:
Lamp luminous flux:
Mains: 1200 lm, Emergency: 1200 lm
Mains: 1200 lm, Emergency: 1200 lm
Mains: 900 lm, Emergency: 900 lm
The following values are indicated in m
The following values are indicated in m
The following values are indicated in m
h
a
d
h
a
2.5
12.9
5.5 12.7
5.5
2.5
14.2
b
c
b
c
d
h
a
5.7 14.2
5.7
2.5
12.3
5.2 12.3
b
c
5.2
d
3.0
13.1
5.9 14.8
5.8
3.0
14.3
6.0 14.3
6.0
3.0
13.7
5.4 13.7
5.4
3.5
14.0
6.1 14.2
6.0
3.5
15.9
6.3 15.9
6.3
3.5
13.3
5.6 13.3
5.6
4.0
15.2
6.3 15.1
6.1
4.0
15.2
6.5 15.2
6.5
4.0
14.5
5.7 14.5
5.7
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
231
Emergency Lighting | Luminaires for central emergency power supply Light Case Type of protection: IP 54 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Modern design - Low maintenance costs - Ball impact protection in acc. with DIN 18032 - Easy to install - Ballasts incorporated
Wall (surface)
232
Emergency Lighting | Luminaires for central emergency power supply Series: Light Case Type of protection: IP 54 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: sheet steel, powder-coated. Removable frame: aluminium, powder-coated. Safety glass: transparent. Hinges: stain‑ less steel. Two cable inlets for through-wiring, cable diameter 7-10 mm. Luminaire equipment installed. Ball impact protected in accordance with DIN 18032. Ballast: EB Available colour (X): 3 = black
Wall (surface)
B
H
L
230 130
130 230
60 47
Ø6
Article number
Type of installation
Lamp/Wattage
671974.81X.Y
Wall (surface)
1 x TC-TEL 32 W
Planning guide: Escape route illumination in accordance with EN 1838
TWINControl (.72)
SINGLE‑ Control (.81)
DUOControl (.82)
•
•
•
•
Dimensions
L 230, B 230, H 150
Spacing table 671974.813
Lamp luminous flux:
a b
Control 1 (.71)
c
d
h
E = 1 lx along the centre line
Mains: 2400 lm, Emergency: 2400 lm The following values are indicated in m h
a
b
2.5
7.7
3.5 10.5
c
4.9
d
3.0
9.0
3.9 12.5
5.6
3.5
10.0
4.4 13.9
6.0
4.0
11.0
4.7 15.3
6.6
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
233
Emergency Lighting | Luminaires for central emergency power supply Weatherproof battens Type of protection: IP 65 - IP 65 type of protection - dustproof and protected against water jets from all directions - Industrial design - Lamp replacement without tools
Wall (surface), Ceiling (surface)
234
Emergency Lighting | Luminaires for central emergency power supply Series: Weatherproof battens Type of protection: IP 65 Protection class: I, II Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: plastic, grey. Lamp: open beam. Integrated EB. Ballast: EB Available colour (X): 9 = grey
Wall (surface), Ceiling (surface) 36 W
Wall (surface), Ceiling (surface) 58 W
H L
H
B
L
B
1258
1558
62
62 Ø10
Ø10
740
Article number
Type of installation
Lamp/Wattage
1050
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671616.75X.Y
Wall (surface), Ceiling (surface)
1 x T26 (T8) 36 W
•
•
•
•
L 1258, B 56, H 122
671617.75X.Y
Wall (surface), Ceiling (surface)
1 x T26 (T8) 58 W
•
•
•
•
L 1558, B 56, H 122
Accessories | Protective tubes for weatherproof battens Replacement diffuser, plastic transparent 981441.000 L 1170, D 38 981442.000 L 1470, D 38
Planning guide: Escape route illumination in accordance with EN 1838 a b
c
d
h
E = 1 lx along the centre line
for T26 36 W for T26 58 W
Spacing table 671616.759
Spacing table 671617.759
Lamp luminous flux:
Lamp luminous flux:
Mains: 3350 lm, Emergency: 3350 lm
Mains: 5400 lm, Emergency: 5400 lm
The following values are indicated in m
The following values are indicated in m
h
a
b
c
2.5
13.9
6.0 23.0
d
h
a
9.5
2.5
15.7
6.8 26.3 11.1
b
c
d
7.4 28.3 11.8
3.0
15.6
6.6 23.5 10.0
3.0
17.3
3.5
16.3
7.0 25.9 10.5
3.5
18.9
8.0 31.4 12.4
4.0
17.9
7.4 27.4 10.9
4.0
20.3
8.5 32.2 13.0
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
235
Emergency Lighting | Luminaires for central emergency power supply Alu-Druckguss (die-cast aluminium) Type of protection: IP 66 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Modern design - Housing made of top quality die-cast aluminium - Low maintenance costs - Compact design - Easy to install
Recessed wall installation, antiglare
236
Recessed wall installation, with diffuser
Emergency Lighting | Luminaires for central emergency power supply Series: Alu-Druckguss (diecast aluminium)
Series: Alu-Druckguss (diecast aluminium)
Type of protection: IP 66 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz
Type of protection: IP 66 Protection class: I Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz
For escape route illumination
For escape route illumination
Housing and frame: die-cast alumi‑ nium, powder-coated. Cover: plastic, opal, shockproof.
Housing and frame: die-cast alumi‑ nium, powder-coated. Cover: plastic, opal, shockproof.
Ballast: EB
Ballast: EB
Available colours (X): 2 = white, 3 = black, 9 = grey
Available colours (X): 2 = white, 3 = black, 9 = grey
Recessed wall installation
Recessed wall installation
BA
B
BA
LA
LA
HE
HE
H
L
H
L
236 228 85
Article number
B
236 228 100
Type of installation
100
85
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671975.91X
Recessed wall installation
antiglare
1 x TC-EL 9 W
-
-
-
-
L 236, B 100, H 5 LA 228 x BA 85, HE 70
671976.91X
Recessed wall installation
with diffuser
1 x TC-EL 9 W
-
-
-
-
L 236, B 100, H 5 LA 228 x BA 85, HE 70
Housing for recessed wall and step luminaires Recess opening: LA 232 x BA 92 mm, max. wall thickness: 20 mm 90-2780 Moulded housing for installation in concrete walls 64253.000
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
237
Emergency Lighting | Luminaires for central emergency power supply Recessed LED step luminaire for installation in concrete steps Type of protection: IP 66 - Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects. - Modern design - Housing made of top quality die-cast aluminium - Low maintenance costs - Compact design - Easy to install
Wall (recessed) (solid wall)
238
Emergency Lighting | Luminaires for central emergency power supply Series: Recessed LED step luminaire for installation in concrete steps Type of protection: IP 66 Protection class: I with EB, III without EB Voltage: 220 - 240 V / 0 Hz, 50 - 60 Hz For escape route illumination Housing: sheet steel, galvanised. Cover: polycarbonate, transparent. Lamellar cover: die-cast zinc, powder-coated. The luminaire housing is used as the moulded housing. During installation, the LED module must be removed from the luminaire housing.Two cable inlets with sleeves for M32 armoured cable (outer sleeve Ø: 24.5 mm, inner Ø: 21 mm). LED module with electronic ballast (connected load: 10 W). The max. connected load of the EB must not be exceeded! Prepared for through-wiring. Ballast: EB Available colours (X): 31 = anthracite metallic, 4 = silver metallic
Wall (recessed) (solid wall)
BA B HE H
LA L
25
122,5 70
190
Article number
110
Type of installation
Type
Lamp/Wattage
Control 1 (.71)
TWINControl (.72)
SINGLEControl (.81)
DUOControl (.82)
Dimensions
671977.00X
Wall (recessed) (solid wall)
with EB
1 x LED 1,92 W
-
-
-
-
L 210, B 90, H 5 LA 190 x BA 70, HE 110
671980.00X
Wall (recessed) (solid wall )
without EB
1 x LED 1,92 W
-
-
-
-
L 210, B 90, H 5 LA 190 x BA 70, HE 110
For connecting diagrams, see pages 119 - 121 | Catalogue number explanations: see page 276 Tender texts available upon request | Specifications subject to alteration
239
240
Standards and regulations European and international regulations EN 1838
Emergency lighting
242 - 243
EN 50172
Emergency escape lighting systems
244
EN 50171
Central power supply systems
245
EN 50272-2
Stationary batteries
245
EN 60598-2-22
Particular requirements Luminaires for emergency lighting
246
VDE 0108, Part 100,
Emergency lighting
246
DIN 4844 -1
Safety signs Viewing distances
262
DIN 4844 -2 Sign design
Safety signs
262
VDE 0100, Part 560,
Systems with nominal voltages of up to 1,000 V
263
VDE 0100, Part 718,
Buildings for gatherings of people
263
(M)LAR
(Model) Wiring systems directive
264
German regulations
Special building directives
264
ASR
Workplace directives
265
BGV
Safe working practices regulations
262
Planning
268 - 269
Exclusion of liability RZB shall not be liable for any loss or damage attributable to any application of, or failure to apply, any information supplied herein. Excerpts from the aforementioned standards and regulations are provided for information purposes only. Other local building regulations may apply. Inasmuch as the applicable requirements, standards and regulations are subject to change, the relevant original versions of such standards and regulations must be applied in each case.
241
European and international regulations
EN 1838 – EMERGENCY LIGHTING Definition of “emergency lighting” Emergency lighting
Emergency escape lighting
Escape route lighting
Standby lighting
Anti-panic lighting (Open area lighting)
High risk task area lighting
Viewing distances
Legend
Safety signs for escape routes must comply with the following requirements:
Safety signs for escape routes must comply with the following requirements:
• Viewing distance (d): formula: d= s x p
Safety colour
Contrast colour
p = sign height s = distance factor 100 (externally illuminated signs) and distance factor 200 (internally lit signs)
Luminance:
p
d
Example: Calculation of an internally lit sign’s height for a required viewing distance of 30 m (d = 30)
The minimum luminance of any green area (safety colour) on the sign must be greater than 2 cd/ square meters. The ratio of maximum to minimum luminance shall be less than 10:1 for each colour.
Applicable equation: d = s x p
p=d/s
p = 30 / 200 = 0.15 m (sign height)
242
The ratio of white colour to green colour luminance must be between 5:1 and 15:1.
Specifications subject to alteration
European and international regulations
EN 1838 – EMERGENCY LIGHTING Specific locations where a luminaire must be provided
at each mandatory exit door
near* each mandatory safety sign
outside and near* each final exit
near* stairs so that each staircase step receives direct light
at each change of direction
near* each first aid post
near* any other change of floor level
at each intersection of corridors
near* each piece of fire fighting equipment and call point
*Note: The term “near” means within 2 meters. First aid posts, fire fighting equipment and call points that are located outside the escape route must be illuminated with a minimum of 5 lux.
Specifications subject to alteration
243
European and international regulations
EN 50172 – EMERGENCY ESCAPE LIGHTING SYSTEMS General
- date and brief details of any change in the emergency lighting installation;
The purpose of emergency escape lighting is to ensure that lighting is provided promptly, automatically and for a suitable time in a specific area during a power failure.
- if any automatic testing device is employed, the main characteristics and mode of operation of that device are to be described.
The installation is to be realized in such a way that emergency escape lighting accomplishes the following (among other things): - illuminates escape route signs; - illuminates escape routes leading to emergency exits; - ensures that fire alarm call points and fire equipment provided along escape routes can be readily located and used (if required);
Maintenance and testing Daily: Indicators of the central power supply are to be visually inspected for correct operation.
- etc.
Monthly:
Emergency escape lighting is to be activated not only on complete failure of the supply to the general lighting but also in the event of a final-circuit failure.
If automatic testing devices are used, the results of the function tests are to be recorded.
Emergency escape lighting is not designed to enable normal work to be continued on the premises in the event of failure of normal or standby lighting.
- a) Switch on in the emergency mode each luminaire and each internally illuminated exit sign via its battery by simulation of a failure of the supply to the general lighting for a period sufficient to ensure that each lamp is illuminated.
For details concerning illuminance levels and measurement, see EN 1838.
Monthly tests are to be carried out as follows:
- During this period, all luminaires and signs are to be checked to ensure that they are present, clean and functioning correctly.
Visibility In locations where building occupants (a) do not have a clear and unobstructed view of an exit sign and/or (b) may have doubts as to the location of an emergency exit, a directional sign (or series of signs) is to be provided in such a way that a person moving toward such sign will be directed to an emergency exit. An exit or directional sign is to be clearly visible at all points along the escape route. All signs marking exits and / or escape routes are to be uniform in colour and format, and their luminance is to comply with EN 1838. Maintained exit signs must be installed for applications where occupants may be unfamiliar with the building.
Anti-panic lighting (Open area lighting) The purpose of open area (anti-panic) lighting is to reduce the likelihood of panic and to enable safe movement of occupants toward escape routes. Such lighting is used in areas with undefined escape routes. Such areas may include halls or premises exceeding 60 square meters in size, or smaller areas if there is an additional hazard such as use by a large number of people.
- At the end of this test period, the power supply to the general lighting is to be restored and any indicator lamp or device is to be checked to ensure that it shows that the normal supply has been restored. In addition to a), for central battery systems, the correct operation of system monitors is to be checked. Annually: If automatic testing devices are used, the results of the full rated duration test are to be recorded. A monthly inspection is be carried out for all other systems, whereby the following additional tests are to be carried out: - each luminaire and internally illuminated sign is to be tested for its full rated duration in accordance with the manufacturer‘s recommendations; - the power supply for general lighting is to be restored and any indicator lamp or device is to be checked to ensure that it is showing that normal supply has been restored. The charging arrangements should be checked for proper functioning; - the date of the test and its results are to be recorded in the system log book.
Log book A log book is to be kept on the premises in the care of a responsible person appointed by the occupant/owner and is to be readily available for examination by any duly authorized person. The log book is to be used to record the following information: - date of commissioning of the system including any certificate relating to changes; - date of each periodic inspection and test; - dates and brief details of any maintenance, inspection and test; - dates and brief details of any defects and of remedial action taken;
244
Specifications subject to alteration
European and international regulations
EN 50171 – CENTRAL POWER SUPPLY SYSTEMS Battery chargers must be capable of automatically charging the associated battery that has been discharged so that it can perform at least 80% of the specified duration at the rated load within 12 h.
Low Power Supply (LPS) Central power supply with a limited rated output power: - 3 h = 500 W
Central Power Supply (CPS)
- 1h = 1, 500 W
Central power supply without any restriction in respect to rated output power.
EN 50272 – StationArY BatterieS Ventilation
Information and warning signs
Batteries are to be installed in well ventilated rooms and cabinets. The minimum cross section of the ventilation opening is to correspond to battery capacity.
Appropriate information and warning signs (pursuant to EN 50272 section 12.1) need to be posted in battery rooms.
Such openings need to be adequately positioned to allow for optimum air exchange (e.g. in opposite walls). Batteries are to be located at least 2 m from wall openings. Exhaust air must be discharged outside the building.
Documentation Documentation containing the following information must be available near the battery: - Name of manufacturer or vendor
Location Batteries are to be installed in protected rooms, if required, electrical or closed electrical operating rooms are to be provided. The batteries may be kept:
- Name of installer - Date of commissioning - Manufacturer’s or vendor’s type designation - Nominated voltage of battery
- in special rooms on the premises
- Nominal capacity with indication of discharge time
- in specific separate areas on the premises
- Safety recommendations
- in enclosures or cabinets on or off the premises
- Recommendations for operating and maintenance
- in battery compartments that are integrated into devices (twin housing)
- Information regarding disposal and recycling
Specific requirements for battery rooms
Such documentation must be at all maintenance and operating personnel’s disposal.
The floor must be rated for the battery weight, and allowance is to be made for the possibility that additional batteries (and hence weight) will be installed down the line. If only authorized personnel are allowed to access to battery rooms, the doors are to be equipped with anti-panic locks. The floors used for sealed batteries are to be electrolyte resistant. If this is not the case, the batteries are to be placed in acid drip pans. The floor area for a person standing within arm’s reach of the battery is to be electrostatic dissipative in order to prevent electrostatic charge generation. Ventilation must comply with EN 50272 and the exhaust air must be discharged outside the building.
Inspections Batteries and their operation conditions have to be checked at regular intervals for correct operation and safety. During such inspections and controls it must be verified whether the following items conform with the manufacturer’s specifications: - Voltage set for the battery charger - Voltage of battery cells/blocks - Electrolyte density and level (if applicable) - Cleanliness - Tightness - Battery connector position (if required) - Ventilation - Plugs and valves - Battery temperature
Specifications subject to alteration
245
European and international regulations
EN 60598-2-22 – PARTICULAR REQUIREMENTS / LUMINAIRES FOR EMERGENCY LIGHTING In emergency luminaires, fluorescent lamps used to provide emergency lighting are to come on without the aid of glow starters. Such starters are not to be in circuit during emergency mode operation. Emergency lighting shall not be provided by means of fluorescent lamps with built-in glow starters.
Self-contained luminaires must be recharged within 24 hours following discharge. The ambient temperature of the battery cells should be at least 5°C; however, an occasional temperature drop to 0°C is admissible.
VDE 0108, PART 100 – EMERGENCY LIGHTING Daily test Indicators for the central power supply are to be visually inspected for correct operation.
Weekly test Function of emergency lighting is to be checked at least once a week. Connection of the power source for safety purposes is required for batterypowered systems.
Monthly test
Yearly test If automatic testing devices are used, the results of the function tests are to be recorded. The yearly test is not to be activated automatically.
Test at 3 year interval
Switching time
Rated duration of power source for safety purposes
Illumination of escape route luminaires, maintained
Central battery system
Group battery system
Self-contained luminaires (as of 08/2010)
Power generation unit (without interruption)
Power generation unit (switching time < 0.5 s)
Power generation unit (switching time 15 s)
Particularly safe network
Every three years (at the most) emergency lighting illuminance is to be measured as provided in DIN EN 1838.
Illuminance
If automatic testing devices are used, the results of the function tests are to be recorded.
Tests are to be carried out by simulating a general lighting power supply failure.
Places of assembly (temporary buildings excluded), theatres, cinemas
1 lx
1s
3h
•
•
•
•
•
•
–
–
Temporary buildings, used for exhibitions
1 lx
1s
3h
•
•
•
•
•
•
–
–
Exhibition halls
1 lx
1s
3h
•
•
•
•
•
•
–
–
Shops
1 lx
1s
3h
•
•
•
•
•
•
–
–
Restaurants
1 lx
1s
3h
•
•
•
•
•
•
–
–
Accomodation facilities, nursing homes
1 lx
1 s - 15 s depending on risk level
8 h (3 h are sufficient, if buttons in accordance with VDE 0108, part 100, section 4.4.8, are available)
•
•
•
•
•
•
•
–
Schools
1 lx
1 s - 15 s depending on risk level
3h
•
•
•
•
•
•
•
–
Car-parks, underground parking garages
1 lx
15 s
1h
•
•
•
•
•
•
•
–
Airports, railway stations
1 lx
1s
3 h (depending on the evacuation concept, for aboveground railway station areas 1 h may be admissible)
•
•
•
•
•
•
–
–
Multi-storey buildings
1 lx
1 s - 15 s depending on risk level
3 h ( 8 h for multi-storey residential buildings, if buttons in accordance with VDE 0108, part 100, section 4.4.8, are not available)
•
•
•
•
•
•
•
–
Escape routes at workplaces
1 lx
15 s
1h
–*
•
•
•
•
•
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
•
–
–
High-risk workplaces
15 lx
0.5 s
Duration of risk for building occupants
Stages
3 lx
1s
3h
* in accordance with BGV A8
246
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS Places of assembly, theatres and cinemas (excluding temporary buildings) Model regulation for places of assembly, June 2005 version - Places of assembly with assembly rooms, used for the gathering together of 200 or more persons
VDE 0108, PART 100 â&#x20AC;&#x201C; EMERGENCY LIGHTING Definition: In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting. Emergency escape lighting must be provided:
- Outdoor places of assembly (including performance areas) with capacity for 1,000 or more persons
- for staircases, landings, exits and essential corridors
- Sports stadiums with capacity exceeding 5,000 persons
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories - for stages and performance areas
Please note:
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
The number of persons is to be calculated as follows:
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms
- for table seating: 1 person per square meter of room floorspace - for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace - for standing room on bleachers: 2 persons per running meter
- for outdoor places of assembly and sports stadiums that are used after dark - for safety signs of exits and escape routes
- for exhibition rooms: 1 person per square meter of room floorspace
Exceptions: This regulations does not apply to the following: - rooms used for religious gatherings; school classrooms and exhibition rooms in museums.
- for illumination of steps In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Places of assembly, VDE 0108, Part Teil 100
3h â&#x2030;¤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
50% 5 sec
En
1,0 lx
Stages, VDE 0108, Part 100 Important note:
3,0 lx
Specifications subject to alteration
The above are model regulations only. Regional building code regulations may also apply in certain cases.
See page 260 for symbol legend
247
German regulations
VDE 0108, PART 100 â&#x20AC;&#x201C; EMERGENCY LIGHTING
MODEL BUILDING CODE REGULATIONS
Temporary buildings
Definition:
Model directive concerning the construction, operation and maintenance of temporary buildings (M-FlBauR), May 2007 version
Lighting
Scope: This directive applies to temporary buildings pursuant to article 76, section 1 of the Model Building Code (MBO). The provisions of this directive regarding rooms in tents apply also to rooms of similar size that are used for similar purposes in other temporary buildings with more than 200 square meters of floorspace.
Tents and similar rooms that are used after dark and have more than 200 square meters of floorspace are to be equipped with emergency lighting that conforms with the relevant technical regulations. The emergency lighting for such rooms is to be illuminated whenever the main lighting is illuminated. The lighting system is to be powered by the building grid; battery powered luminaires are admissible only if securely installed. In the event of a general power failure, battery powered luminaires are to be on hand.
Please note: The number of persons is to be calculated as follows: - for table seating: 1 person per square meter of room floorspace - for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace
Exceptions: This directive does not apply to tents used for camping or medical services or for tents with less than 75 square meters of floorspace.
Temporary buildings, VDE 0108, Part 100
3h â&#x2030;¤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
248
See page 260 for symbol legend
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS
VDE 0108, PART 100 – EMERGENCY LIGHTING Definition:
Pubs and restaurants Model regulation for places of assembly (MVStättV), version
June 2005
MVStättV applies to the following: Restaurants whose dining area floorspace exceeds 200 square meters; and pubs and discotheques that have standing room and more than 100 square meters of floorspace.
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting. Emergency lighting must be provided: - for staircases, landings, exits and essential corridors
Please note:
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories
The number of persons is to be calculated as follows:
- for stages and performance areas
- for table seating: 1 person per square meter of room floorspace
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspaces
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms - for outdoor places of assembly and sports stadiums that are used after dark
Exceptions:
- for safety signs of exits and escape routes
none
- for illumination of steps In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Restaurants, VDE 0108, Part 100
3h ≤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
Specifications subject to alteration
See page 260 for symbol legend
249
German regulations
VDE 0108, PART 100 â&#x20AC;&#x201C; EMERGENCY LIGHTING
MODEL BUILDING CODE REGULATIONS
Multi-storey buildings
Definition:
Model Directive concerning the construction, operation and maintenance of multi-storey buildings (M-HHR), April 2008 version
Emergency escape lighting
Special requirements and variances pursuant to article 51, section 1 of the Model Building Code (MBO) for the construction and operation of multi-storey buildings (paragraph 2, section 4, no. 1 of MBO) are provided herein. Multi-storey buildings are buildings whose height exceeds 22 meters.
The emergency escape lighting system in multi-storey buildings must automatically switch on in the event of a general lighting failure.
Emergency escape lighting must be provided: - on escape routes - in front of lifts
Exceptions:
- for safety signs on escape routes
Emergency escape lighting time can be reduced to 3 hours if the lighting is timer-controlled and switched via master lighting switches.
Multi-storey building, VDE 0108, Part 100
1 - 15 sec
8h
DS
BS CPS
je nach Panikrisiko oder Gefährdungsbeurteilung
LPS
EB
NEA < 15 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
250
See page 260 for symbol legend
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS
VDE 0108, PART 100 â&#x20AC;&#x201C; EMERGENCY LIGHTING
Accomodation facilities and nursing homes
Definition:
Model regulation regarding the construction, maintenance of accomodation facilities (MBeVO).
In accommodation facilities emergency escape lighting must be provided:
operation
and
- in all essential corridors and staircases
The provisions of this regulation apply to accomodation facilities with more than 12 guest beds.
- in rooms and landings between essential staircases and exits - for safety exit signs - for steps in essential corridors
Please note: Emergency escape lighting time can be reduced to 3 hours if the lighting is timer-controlled and switched via master lighting switches.
Exceptions: This regulation does not apply to holiday apartments.
Accomodation facilities, VDE 0108, Part 100
1 - 15 sec
8h
DS
BS CPS
je nach Panikrisiko oder Gefährdungsbeurteilung
LPS
EB
NEA < 15 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
Specifications subject to alteration
See page 260 for symbol legend
251
German regulations
VDE 0108, PART 100 â&#x20AC;&#x201C; EMERGENCY LIGHTING
MODEL BUILDING CODE REGULATIONS
Schools
Definition:
Model directive regarding building code regulations for schools (MSchulbauR), April 2009 version
Emergency escape lighting must be provided in halls that are intersected by escape routes, in essential corridors and staircases as well as in windowless common rooms.
This directive applies to requirements pursuant to paragraph 51, section 1 of the Model Building Code (MBO) for general education and vocational schools that are not used solely for adult education classes.
Please note: Insofar as not otherwise provided by the MSchulbauR directive, the provisions of the MBO building code shall apply. Any workplace safety regulations issued by insurers, trade associations and so on, as well as workplace regulations or regional laws that apply to schools apply.
Exceptions: This directive does not apply to colleges, universities, academies, adult education centres, music schools, dance schools, driving schools and the like.
Schools, VDE 0108, Part 100
1 - 15 sec
3h
DS
BS CPS
je nach Panikrisiko oder Gefährdungsbeurteilung
LPS
EB
NEA < 15 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
252
See page 260 for symbol legend
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS
VDE 0108, PART 100 – EMERGENCY LIGHTING
Car-parks
Definition:
Regulation regarding the construction, operation and maintenance of car-parks (M-GarVO), May 1993 version (as amended by the resolution of 30 May 2008)
Open car-parks are car-parks (a) with non-closeable openings that (i) lead directly outside and (ii) whose surface accounts for at least one third of the total surface of the facility’s exterior walls; (b) at least two of whose opposing enclosing walls containing such openings are not more than 70 meters apart; and (d) with continuous cross ventilation.
An emergency escape lighting system for the illumination of escape routes must be installed in large enclosed car-parks (excluding large single-level car-parks with regular users). Large car-parks are car-parks with net floorspace exceeding 1,000 square meters.
Small open car-parks are small car-parks with non-closeable openings that (i) lead directly outside and (ii) whose surface accounts for at least one third of the total surface of the facility’s exterior walls. Closed car-parks are car-parks that do not meet the above criteria.
Exceptions: none
Car-parks, VDE 0108, Part 100
1h ≤ 15 sec
DS
BS CPS
LPS
EB
NEA < 15 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
Specifications subject to alteration
See page 260 for symbol legend
253
German regulations
VDE 0108, PART 100 – EMERGENCY LIGHTING
MODEL BUILDING CODE REGULATIONS
Exhibition places
Definition:
Model regulation for places of assembly (MVStättV), June 2005 version
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.
Places of assembly with assembly rooms, used for the gathering together of 200 or more persons.
Emergency escape lighting must be provided: - for staircases, landings, exits and essential corridors
Please note:
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories
The number of persons is to be calculated as follows:
- for stages and performance areas
- for table seating: 1 person per square meter of room floorspace
- in staff rooms larger than 20 square meters of floorspace, office rooms excluded
- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace
- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms
Exceptions:
- for outdoor places of assembly and sports stadiums that are used after dark
Pursuant to number 3 of the MVStättV (places of assembly regulation), only exhibition rooms of museums are excluded from the scope of application.
- for safety signs of exits and escape routes
The above regulation applies, however, to museums with other rooms of assembly pursuant to article 2, no. 3 (i.g. foyer, discussion rooms, cafeteria or the like) which fall within the scope of article 1.
- for illumination of steps In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Exhibition places, VDE 0108, Part 100
3h ≤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
254
See page 260 for symbol legend
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS
VDE 0108, PART 100 – EMERGENCY LIGHTING
Stages
Definition:
Model regulation for places of assembly (MVStättV), June 2005 version)
In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.
Places of assembly with assembly rooms, used for the gathering together of 200 or more persons.
Emergency escape lighting must be provided: - for staircases, landings, exits and essential corridors
Exceptions: Performance spaces with less than 20 square meters of floorspace are not classified as performance areas.
- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories - for stages and performance areas - in staff rooms larger than 20 square meters of floorspace, office rooms excluded - in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms - for outdoor places of assembly and sports stadiums that are used after dark - for safety signs of exits and escape routes - for illumination of steps In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.
Stages, VDE 0108, Part 100
3h ≤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
50% 5 sec
En
1,0 lx
Bühnen VDE 0108 Teil 100 Important note:
3,0 lx
Specifications subject to alteration
The above are model regulations only. Regional building code regulations may also apply in certain cases.
See page 260 for symbol legend
255
German regulations
VDE 0108, PART 100 â&#x20AC;&#x201C; EMERGENCY LIGHTING
MODEL BUILDING CODE REGULATIONS Definition:
Points of sale Model regulation regarding the construction, maintenance of retail outlets (MVkVO)
operation
and
In retail outlets, emergency escape lighting must be provided: - inside shops
Shops and shopping malls with more than 2,000 square meters of floorspace
- in staircases, landings and shopping streets - in corridors that are essential for customers - in staff rooms
Exceptions:
- in lavatories with more than 50 square meters of floorspace
none
- in rooms that accommodate electrical equipment or technical building systems - for safety exit signs and illumination of steps.
Points of sale, VDE 0108, Part 100
3h â&#x2030;¤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
256
See page 260 for symbol legend
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS
VDE 0108, PART 100 – EMERGENCY LIGHTING
Workplaces
Definition:
Workplace directive concerning emergency escape lighting (ASR 7/4)
Escape route lighting
- Escape routes in working areas and storerooms with more than 2,000 square meters of floorspace
Escape route lighting must allow for safe evacuation by providing sufficient illumination for escape routes and signs.
- Escape routes in working areas and staff rooms whose floors are more then 22 meters above the ground
Illuminance
- Escape routes located in the following types of areas with more than 100 square meters of floorspace: working areas without windows, skylight or the like; rooms that are kept dark for operational purposes
Escape routes must be lit with a minimum of 1 lux. This value is that measured at the end of the luminaire’s operating time on the horizontal plane located 0.2 meters above floor level or the stairs.
- Escape routes located in the following types of areas with more than 30 but less than 100 square meters of floorspace: in working areas without windows, skylight or the like; rooms that are kept dark for operational purposes. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.
Minimum operating time: 1 hour.
- Escape routes in potentially explosive or toxic workplaces, as well as in workplaces in which non-sealed radioactive materials are handled, with more than 100 square meters of floorspace - Escape routes in potentially explosive or toxic working places, as well as in workplaces in which non-sealed radioactive materials are handled, with more than 30 and less than 100 square meters of floorspace. For such escape routes, luminaires that can be seen from any point are to be installed at all exits. - For escape routes in laboratories with more than 600 square meters of floorspace and where workers are exposed to specific hazards - For escape routes in laboratories with more than 30 and less than 600 square meters of floorspace and where workers are exposed to specific hazards. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.
Exceptions: none
Workplaces, VDE 0108, Part 100
1h ≤ 15 sec
BS
BS CPS
LPS
EB
≤ 15 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
Specifications subject to alteration
See page 260 for symbol legend
257
German regulations
VDE 0108, PART 100 – EMERGENCY LIGHTING
MODEL BUILDING CODE REGULATIONS
High risk task areas
Definition:
Workplace directive concerning emergency escape lighting (ASR 7/4)
General
High risk task area lighting must be provided in places where staff or third parties are exposed to specific hazards, or where accidents are very likely to occur in the event of a general lighting failure.
The technical specifications for high risk task area lighting are determined by the type of activity and room involved. Illuminance
Please note: The emergency escape luminaires for particularly hazardous workplaces have to be installed in such a way that the required illuminance values are achieved within the entire area of hazardous risk.
The illuminance values of high risk task area lighting are determined by nominal illuminance (En) pursuant to workplace directive “ASR 7/3: Artificial lighting” for each type of activity and room. The illuminance of high risk task area lighting must be E = 0.1 x En, however not less than 15 lux. This illuminance must continue for the duration of the risk, subject to a one hour minimum. Delay on startup The maximum delay on startup for high risk task area lighting is 0.5 seconds.
High-risk workplaces, VDE 0108, Part 100
≤ 0,5 sec
Zeitraum der Gefährdung
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
En
50% 5 sec
E = 0,1 x En mindestens aber 15 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
258
See page 260 for symbol legend
Specifications subject to alteration
German regulations
MODEL BUILDING CODE REGULATIONS
VDE 0108, PART 100 – EMERGENCY LIGHTING Definition:
Airports / railway stations
none
Please note: For above-ground railway station areas a rated duration of 1 hour may be admissible, depending on the evacuation plan.
Exceptions: none
Airports / railway stations, VDE 0108, Part 100
3h ≤ 1,0 sec
DS
BS CPS
LPS
EB
NEA < 0,5 sec
EN 1838 100% 60 sec
En
50% 5 sec
1,0 lx
Important note: The above are model regulations only. Regional building code regulations may also apply in certain cases.
Specifications subject to alteration
See page 260 for symbol legend
259
German regulations
SYMBOL LEGEND VDE 0108, PART 100
Switching time ≤ 0.5 sec
Switched maintained
GDS
≤ 0,5 sec
Central battery systems
Switching time ≤ 1.0 sec ≤ 1,0 sec
CPS
Group battery systems
Switching time ≤ 15 sec ≤ 15 sec
1 - 15 sec je nach Panikrisiko oder Gefährdungsbeurteilung
1h
LPS
Switching time 1 - 15 sec (depending on panic risk or danger level)
Single battery systems EB
Rated duration: 1 hour NEA < 0,5 sec
3h
Rated duration: 3 hours NEA < 0 sec
8h
Rated duration: 8 hours NEA < 15 sec
Zeitraum der Gefährdung
BS
DS
BS
GBS
260
Rated duration: (duration of danger)
Emergency escape luminaire, non-maintained
Switched non-maintained
Nominal illuminance 3.0 lx
3,0 lx
100% 60 sec
En
Emergency power supply system < 15 sec
Nominal illuminance 1.0 lx
1,0 lx
Escape route sign, maintained
Emergency power supply system < 0 sec
Nominal illuminance 0.5 lx
0,5 lx
Escape route sign, nonmaintained
Emergency power supply system < 0.5 sec
50% 5 sec
E = 0,1 x En mindestens aber 15 lx
Nominal illuminance 50% Nominal illuminance 100%
> 10% of nominal illuminance min. E > 15 lx
Specifications subject to alteration
German regulations
Safety lighting costs Purchase costs
Installation costs
Operating costs
Luminaires Battery/Batteries Systems
Luminaire installation Set-up (CPS/LPS)
Power supply Maintenance Spare parts
Cost savings options Purchase costs
Installation costs
Operating costs
During the planning phase, cost optimization procedures can be applied to system purchases.
Purchase of easy to install luminaires
State of the art LED technology reduces energy costs and battery capacities
Mixed operation technology obviates the need for cabling
Use of lamps with a long service life reduces repair and spare parts costs Automatic testing systems reduce labour costs
Costs for weekly tests Luminaires with a test button
Luminaires with an automatic self-test function
Luminaires with an automatic self-test function and testing system (DALI, MWEBplus, MultiDigit®)
Employee must test all luminaires once a week, which requires a lot of time. Ceiling mounted luminaires can be tested only using a ladder.
Employee must only control all luminaires once a week.
Employee receives testing results at a central workstation or via e-mail.
7 minutes per luminaire
3 minutes per luminaire
Total of 5 minutes
10.00 €
10.00 €
10.00 €
30 luminaires
30 luminaires
30 luminaires
Time required for weekly function test
210 min.
90 min.
5 min.
Costs for weekly function test
35.00 €
15.00 €
0.83 €
1,820.00 €
780.00 €
43.33 €
Tasks
Time required Hourly labour costs System with:
Annual costs
Specifications subject to alteration
261
German regulations
DIN 4844, PART 1 And PART 2
BGV A 8
Design of escape signs square
Safety and health signs
rectangular b = 2 x a
1. Scope of application
a
a
These safety provisions apply to safety and health signs at work.
2. Definitions g
g a
b
Luminance Safety colour (green)
Contrast colour (white)
Escape sign means a safety sign indicating an escape route, emergency exit, first-aid station, or the route to such facilities.
3. Escape routes Escape routes are clearly marked routes that allow (a) employees to evacuate a facility; and (b) rescue and evacuation of injured employees or employees exposed to hazards.
4. Visibility Luminance during mains-power operation in accordance with DIN 4844Part 1 (05/2005): average luminance of contrast colour: min. 500 cd/ square meter
- Safety signs must be installed in such a way that they are clearly visible and securely attached at all times. They must be made of materials that are resistant to the environmental factors. - If a safety sign is installed at a location with inadequate natural light, the signâ&#x20AC;&#x2122;s visibility is to be ensured via artificial lighting.
5. Maintenance
Design of escape signs Escape signs are always to be composed of a directional arrow and the escape route/ exit symbol. Directional arrow
Escape route / Emergency exit
The employer is responsible for maintenance of workplace health and safety signs.
6. Testing - The employer is to ensure that all health and safety signs are inspected at two years intervals at a minimum. - The employer is to ensure that all technical elements (such as luminaires) are tested at least once a year by an experienced technician.
Directional arrow
Escape route / Emergency exit
Emergency exit
262
Specifications subject to alteration
German regulations
VDE 0100, PART 718 – BUILDINGS FOR GATHERINGS OF PEOPLE Scope This standard applies to, among others, the installation of electrical and safety systems in the following types of structures that are used for gatherings of people:
Site plans and information concerning each single electric load as well as its location are also to be available. Such plans are to indicate the following: - Exact position of all electrical operating locations
- Places of assembly
- Exact position of distributors, cables and routes (except for final circuits)
- Exhibition halls
- All safety related electrical loads and circuit names
- Theatres and cinemas
- Safety related control and monitoring units
- Sports stadiums
Cross sections
- Points of sale - Restaurants
Final circuits must have a cross section of min. 1.5 mm².
- Nursing homes - Accomodation facilities
Displayed information for safety monitoring purposes
- Schools - Car-parks - Underground car-parks
For reasons of safety, system operation is to be monitored and the following information is to be displayed:
- Swimming pools
- System ready for operation
- Airports
- Battery mode
- Railway stations
- System error
- Multi-storey buildings - Workplaces
Test logs
Power sources
The facility vendor is to provide the facility operator with log books where all test results are to be recorded and stored for a period of 4 years.
DC circuits must be protected against overload by a 2-pole fuse
Electronic log books from a DIN EN 62034 conformant automatic testing system are also regarded as valid log books if the test results can be archived for a period of 4 years and displayed or printed out.
Connecting diagrams A detailed connecting diagram for the electric system must be available near the main distribution board of the backup power supply and is to indicate the following: - Safety circuits (including monitoring systems) - Type and number of loads per circuit - Load of each single circuit - Total system load
VDE 0100, PART 560 – Systems with nominal voltages of up to 1 000 V Electric circuits
Power sources
Safety circuits must be physically isolated from other cable routes and may pass through fire risk areas – but not explosion risk areas - if they are fire resistant.
If only one backup power source is available it is not to be used for any other purpose.
However, conducting safety circuits through fire risk areas should be avoided wherever possible.
Absence of feedback Errors and failures in any safety system are not to affect the loads of any other system.
Specifications subject to alteration
263
German regulations
BUILDING CODE REQUIREMENT Building permit Regional German building codes
Workplace health and safety regulations
Landesbauordnung (MBO)
Workplace regulation
- (Model) School building directive 07/1998
Workplace directive
- (Model) Places of assembly regulation 06/2005
Trade and Industry Regulation
- (Model) Points of sale regulation 09/1995
Regulations for the prevention of accidents (BGV A8, BGR 216, BGR 131 etc)
- (Model) Directive for multi-storey buildings 04/2008 - (Model) Car-parks regulation 07/1997 - (Model) Accomodation facilities regulation 12/2000 - (Model) Directive concerning temporary buildings 05/2007 - ...
Compliance with generally accepted standards is required
WIRING SYSTEMS DIRECTIVE ((M) LAR) (11/2005) 1. Scope This directive applies to - Wiring systems in the following locations: essential stairwells; landings and spaces that connect essential stairwells and exits; essential corridors, excluding open corridors in front of external walls, - Passing cables through walls, ceilings and the like, - Fire protection for electrical wiring systems.
- be enclosed in components (including the enclosures) that exhibit adequate fire resistance duration and that are composed of incombustible materials (excluding the enclosures); operability of the distributorâ&#x20AC;&#x2122;s electric components must be ensured in the event of fire for the entire fire resistance duration. The fire resistance duration must be no less than 30 minutes for: - Emergency escape lighting systems, to the exclusion of wiring systems that supply power to emergency escape lighting within only one fire compartment of one storey or within one stairwell; maximum floorspace per fire compartment: 1,600 square meters.
2. Definitions Wiring systems are composed of electric cables and/or conduits and the relevant fittings, connections, monitoring and control systems, power supplies, distributors and insulating material for cables, including the attachment hardware and coatings used for the wires/conduits. Fiberoptic cables and electric cables are classified as electric wires.
3. Fire resistance Fire-protected distributors for electrical wiring systems pursuant to section 5.3 of directive (M)LAR must: - be located in suitable spaces that are not used for other purposes and that are separated from other rooms by walls, ceilings or doors that are adequately fire-protected and â&#x20AC;&#x201C; apart from the doors â&#x20AC;&#x201C; made of incombustible materials - be kept in separate housings with a certified fire-resistance duration rating; or
264
Specifications subject to alteration
German regulations
WORKPLACE DIRECTIVES New „Technical rules for workplaces“
Escape and rescue route plan
ASR A1.3 Safety and health signs (04/2007) ASR A2.3 Escape routes, emergency exits, escape and rescue plan (08/2007) ASR A3.4/3 Emergency escape lighting, optical safety guidance systems (05/2009) The regulation titled BGR 216: Optische Sicherheitsleitsysteme (einschließlich Sicherheitsbeleuchtung) (optical safety guidance systems (including safety lighting)), will remain in force until 31 August, 2010, along with the regulation titled ASR A3.4/3. In May 2009, the old workplace directive titled ASR 7/4: Sicherheitsbeleuchtung (emergency escape lighting) was superseded by the regulation titled ASR A3.4/3.
ASR A1.3 Contents 1. Objectives 2. Scope 3. Definitions 4. General 5. Signs 6. Escape and rescue plans 7. Labelling of containers and conduits containing dangerous substances Annex(es)
Directional arrow
Escape route / Emergency exit
Objectives This directive ASR A1.3 lays down the requirements for safety and health signs at workplaces. Pursuant to article 3 of the workplace regulation titled Arbeitsstättenverordnung and section 1.3 of the appendix thereof, safety and health signs are to be used in order to avert workplace safety and health risks.
Scope The workplace regulation Arbeitsstättenverordnung implements EU Directive 92/58/EEC on the minimum requirements for the provision of safety and/or health signs at work.
Specifications subject to alteration
265
German regulations
WORKPLACE DIRECTIVES ASR 2.3 Escape routes, emergency exits, escape and rescue plan Contents 1. Objectives 2. Scope 3. Definitions 4. General 5. Design, dimensions 6. Application 7. Signs
Emergency escape lighting Section 8 of the directive titled ASR A2.3 (concerning escape routes, emergency exits, escape and rescue plans) defines the conditions under which emergency escape lighting is required for escape routes. In the scenarios described in the said section 8, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting. Escape routes are to be equipped with emergency escape lighting insofar as safe evacuation of the workplace in the event of a general lighting failure cannot be guaranteed. Emergency escape lighting may be required for example in workplaces that exhibit the following characteristics (among others):
8. Emergency escape lighting
- Workplaces with a large number of employees or that are located in tall buildings; workplaces with high risk areas or unclear escape routes
9. Escape and rescue plan
- Workplaces used by persons who are unfamiliar with the place
Objectives This workplace directive lays down the requirements (pursuant to article 4, paragraph 4, and item 2.3 of the appendix to the workplace regulation titled Arbeitsstättenverordnung) concerning (a) the installation and maintenance of escape routes and emergency exits; and (b) escape and rescue plans, with a view to ensuring safe workplace evacuation in the event of danger.
Scope This workplace directive applies to the installation and maintenance of escape routes and emergency exits in buildings and similar structures to which employees have access during work, as well as to the elaboration of escape and rescue plans and related exercises. Such routes and plans are to be elaborated in a manner that allows for the possibility that outside parties may be present during an emergency.
- Workplaces where large spaces such as open-plan offices or retail spaces must be traversed during an evacuation - Workplaces with no natural light, such as basement rooms.
Escape and rescue plan The employer is to devise a suitable escape and rescue plan for those areas of the workplace whose location, dimensions and/or type necessitate the use of such a plan. Escape and rescue plans must be up to date, easy to understand and read, and must be elaborated using standard safety colours and symbols. For requirements concerning escape and rescue plans, see the regulation titled ASR A1.3. Escape and rescue plans are to incorporate graphic elements indicating the following: - Site plan or parts thereof
This workplace rule does not apply
- Escape and rescue routes
- to installation and maintenance of the following:
- First-aid posts
a) outdoor workplaces that are not enclosed on all sides
- Fire fighting equipment
b) building construction sites
- Assembly point location
c) areas in any structures that are occupied solely for maintenance and inspection purposes
- Point of location of the user (“you are here” indication)
d) areas in any structure where handicapped people are employed
The escape and rescue plans is to be displayed in sufficient number in suitable areas of the workplace.
- to leaving work equipment behind in the event of danger within the meaning of article 2, paragraph 1, of the Industrial Safety and health regulation (Betriebssicherheitsverordnung). In comparable situations, this directive may be applied to any excluded areas. If not, specific measures have to be taken to ensure employee safety in the event of danger. Signs Escape routes, emergency exit and door signs are to conform with the directive titled ASR A1.3.
266
Specifications subject to alteration
German regulations
WORKPLACE DIRECTIVES ASR 2.3 Escape routes, emergency exits, escape and rescue plan Section 8 of the directive titled ASR A2.3 defines the conditions under which emergency escape lighting is required for escape routes. In the scenarios described in this section of the directive, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.
ASR A3.4/3 Emergency escape lighting, optical safety guidance systems Contents 1. Objectives 2. Scope 3. Definitions 4. Emergency escape lighting 5. Optical safety guidance systems 6. Operation, maintenance and testing 7. Supplementary requirements for building sites Objectives
(ASR A2.3 Paragraph. 8). Workplaces where employee health and safety are at risk in the event of a general lighting failure and where emergency escape lighting is required include the following among others: High-risk workplaces: - Laboratories - Rooms that are darkened for operation - Rooms that accommodate electrical equipment or technical building systems - Workplaces with a large number of employees - Workplaces that are located in tall buildings - Workplaces with high-risk areas - Workplaces with unclear escape routes - Rooms or areas used by persons who are unfamiliar with the place - Workplaces where large spaces such as open-plan offices must be traversed during an evacuation - Rooms with no natural light - Working areas where long trailing equipment or machines are used - Areas containing control units for systems that are subject to continuous monitoring (e.g. control rooms) - Workplaces with immersion baths containing heated liquids, casting pits or acid baths
This workplace directive specifies the requirements concerning the installation and maintenance of emergency escape lighting and optical safety guidance systems pursuant to article 3, paragraph 1, and article 4, paragraphs 3 and 4, and notably item 2.3 paragraph 1 and item 3.4 paragraph 3 of the appendix to the workplace regulation titled Arbeitsst채ttenverordnung.
- Building construction sites
Scope
Building construction sites used after dark
Directive ASR A3.4/3 applies in many cases to building construction sites because of the high risk for persons. Emergency escape lighting is essential in cases where there is not sufficient natural light to light escape routes so as to allow for safe workplace evacuation.
This workplace directive (a) applies to the installation and maintenance of emergency escape lighting and optical safety guidance systems in workplaces; (b) cites examples of types of workplaces which may require emergency escape lighting or optical safety guidance systems: and (c) lays down technical specifications for emergency escape lighting and optical safety guidance systems and the use thereof.
Emergency escape lighting 4.1 Escape route lighting Section 8 of the directive titled ASR A2.3 defines the conditions under which emergency escape lighting is required for escape routes. In the scenarios described in this section of the directive, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.
Escape route illumination Identification of escape routes via the relevant signs
4.2 High risk task area lighting In workplaces where accidents are likely to occur in the event of a general lighting failure, the required illuminace of the emergency escape lighting is to be reached within 0.5 seconds and must continue at least for the duration of the risk. Escape routes are to be equipped with emergency escape lighting insofar as safe evacuation of the workplace in the event of a general lighting failure cannot be guaranteed.
Specifications subject to alteration
The illuminance of emergency escape lighting for escape routes must be at least 1 lux, with a uniformity of less than 40:1.
267
Escape LIGHTING PLANNING
PLANNING
Important issues:
1. Is safety lighting required?
Building permit, building codes and regulations, work safety laws, workplace regulations, etc.
2. Wich type of self-contained or central battery system (CPS / LPS) is to be used?
See VDE 0108, Part 100, table A1 (see table on page 246)
3. Which is the required nominal operating time?
See VDE 0108, Part 100, table A1 (see table on page 246)
4. Escape and rescue routes plan
The escape and rescue route plan indicates all mandatory escape routes and emergency exits (in the absence of such a plan, escape routes and emergency exits are to be indicated by the plannner or architect).
5. Luminaires
See EN 1838 for detailed information concerning the installation of safety signs. The number of emergency escape luminaires is to be determined using the spacing table (Leuchtenabstandstabelle) or a lighting calculation formula.
The above ALSO applies to the planning process for a single-battery system!
Potencia y circuitos 6. Capacity of all luminaires = total capacity
The battery aging factor must be factored in. We recommend that a 25% aging factor be applied.
7. Total capacity, including the aging factor (loss in capacity) = battery capacity
See table on page 125, where ventilation cross sections are indicated as well.
8. Number of fire compartments
Consult your planner or architect. Fire compartment dimensions in accordance with directive MLAR (exceptions are allowed in some regions).
9. Number of circuits per fire compartment
=> mixed operation => 2 circuits per fire compartment at a minimum => standard operation => 4 circuits per fire compartment at a minimum Important note: Maximum no. of luminaires per circuit: 20, Maximum circuit load: 815 VA !
10. Number of circuits divided by 4 = number of circuit modules
11. Sub-stations
268
Power supply cable
max. 20 luminaires or 815 VA max. 20 luminaires or 815 VA max. 20 luminaires or 815 VA max. 20 luminaires or 815 VA
For calculating the number of circuits and modules per sub-station, the same calculation system that is used for central battery systems circuits calculation is to be applied.
Specifications subject to alteration
Escape LIGHTING PLANNING
PLANNING For sub-stations planning, please note:
Fire compartment 1 max. 1,600 square meters
Fire compartment 2 max. 1,600 square meters
Fire compartment 3 max. 1,600 square meters
Active star network Please note that for this type of network an output in the CPU must be provided for each sub-station. F 90 E 30
EIB BUS
Fire compartment 1 max. 1,600 square meters
Fire compartment 2 max. 1,600 square meters
Fire compartment 3 max. 1,600 square meters
Linear network E 30 Junction box
Please note that for this type of network E30 junction boxes are to be provided for each fire compartment.
F 90 E 30
EIB BUS
E 30 Junction box
E 30 junction box NYM to distributor in accordance with LAR
E 30 Power supply cable
Specifications subject to alteration
Installation example
E 30 fused junction box
269
Exhibition stand emergency lighting light+building 2010
270
Appendix Service EVG symbol
272 - 273 274
LED symbol
275
Catalogue number codes
276
Motifs and lettering for emergency luminaires
277
Motifs and lettering for luminaire signs
278 - 279
Lamps
280
Terms of conditions of sale and delivery
281
Catalogue number index
282 - 286
Alphabetical index
287 - 288
Technical support
289
After Sales Service
289
Contact for emergency lighting
289
271
Service
Abbreviations L
Protection classes
Lengh
B
Width
H
Height
D
Diameter
Protection class I Luminaires for connection to a protective conductor provided on site. The protective conductor terminal is marked . In case of malfunction: Protection through power supply switchoff by overcurrent protection device.
LP Pendant length AL Extension DA Recess opening (width x length or Ø) HE Luminaire installation height Luminaire with Edison lampholder EVG electronic ballast BS non-maintained DS maintained GDS switched maintained TLS staircase light circuit LPS Low Power Supply CPS Central Power Supply NEA Emergency power supply system EPS Emergency power supply system
Protection class II Base insulation protects against direct contact. In case of malfunction: Additional or reinforced insulation protects against indirect contact. Many protection class I luminaires are also available with protection class II on request. Protection class III Luminaires for connection to safety extra-low voltage (SELV, max. 50 V AC), e.g. using safety transformers or other sources of voltage with comparable safety features. In case of malfunction: Protection through effectively harmless voltage. Mains connection via luminaire equipment with dual or reinforced insulation on the mains side. The information relating to the resistance of our luminaires to solid objects and water is based on EN 60598/VDE 0711. Specifications subject to alteration.
SK Electric circuit IOM In/Out module
Types of protection according to EN 60598/VDE 0711 1st digit: Protection against solid objects IP 2X
Protection against penetration of solid objects
> 12.5 mm
IP 3X
Protection against penetration of solid objects
> 2.5 mm
IP 4X
Protection against penetration of solid objects
> 1 mm
IP 5X
Protection against dust penetration
IP 6X
Dust-proof
2nd digit: Protection against water IP X1
Luminaires are protected against water drops
(vertically falling drops of water)
IP X2
Luminaires are protected against water drops
(drops of water up to 15° from the vertical)
IP X3
Luminaires are protected against rain
IP X4
Luminaires are protected against water sprays
IP X5
Luminaires are protected against water jets
IP X6
Luminaires are protected against rough sea or
heavy jets of water
IP X7
Protection against temporary immersion
_ _ m IP X8
Protection against continuous immersion
Electric circuit identification labels | VDE 0108/DIN 56932 A sheet of circuit identification labels in accordance with DIN 56932; self-adhesive white plastic foils with red silk screen printing for application on plain surfaces. One sheet contains 12 circuit identification labels; circuit numbers 001 to 150 are available from stock. Please indicate circuit numbers when placing your order, e.g. 99350/017! Article number 99350
Electric circuit identification labels | VDE 0108/DIN 56932 Light plastic plate for application on roughcast or any other irregular surfaces to be used as support for circuit identification labels 99350. Article number 99351
Circuit identification labels, blank A sheet of circuit identification labels in accordance with DIN 56932; self-adhesive white plastic foils with red silk screen printing for application on plain surfaces. One sheet contains 12 circuit identification labels for application of personalized lettering; Article number 99350.1
The type of protection indicated for surface mounted, recessed, pole or pendant luminaires only applies for the defined and/or permitted type of luminaire installation.
272
Specifications subject to alteration
Service
Ballast
Electrotechnical safety We guarantee that we have manufactured and tested all of the luminaires in this catalogue carefully in accordance with international standard EN 60598 (VDE 0711). Special luminaires are manufactured in accordance with this standard.
Our luminaires are mainly fitted with low-loss ballast. They are designed for 230 V/50 Hz (equipment with other specifications is available on request). Luminaires with electronic ballast are indicated by the code at the end of the catalogue number, e.g. .79 or have their own separate order number with explanatory text.
Safety marks
Electrotechnical variants and additions Codes are marked by a two-digit suffix separated by a point at the end of
The ENEC mark is a European test and certification mark for luminaires and electrical luminaire components.
the catalogue number.
Luminaires bearing this mark can be mounted directly onto normally inflammable surfaces (in accordance with EN 60598-1).
Code .03
Version with automatic self-test function and feedback to PZ 50
Luminaires bearing this mark have a limited surface temperature and are suitable for premises where dust or fibres can create a fire risk.
Code .04
Version with automatic self-test function and feedback to MultiDigit® and MWEBplus DALI
Luminaires bearing this mark are suitable for mounting on or in furniture made of materials with unknown properties; this applies, in particular to flammability. Code .07
Luminaires marked with the “ball impact protection” symbol are suitable for use in sports facilities. They are manufactured in accordance with the test conditions defined in VDE 0710.
Version with automatic self-test function and feedback to DALI unit EVG
Code .79
ta
Versions with electronic ballast Control 1
The CE mark is not a safety mark. It indicates that the product complies with European Union directives.
Code .71
Monitoring module for GV 1500 and RZBbasic TWIN-Control
Code .72
Symbol explanations
Monitoring module for mixed operation via switch for GV 1500 and RZBeasy 202. 3 different switching types can be switched and operated contemporaneously in one circuit. SINGLE-Control
DUO-Control
Luminaires for escape route identification Luminaires for escape route illumination
Code .81
Monitoring module for LUXIFAIR and LUXIFAIRlight
Luminaires marked “ta 15°C” are designed for ambient temperatures of 15°C and are also suitable for use outdoors.
Sign for luminaires with Edison lampholder
Code .82
Monitoring module for mixed operation via switch for LUXIFAIR and LUXIFAIRlight
General information Use of emergency lighting modules The distances between EB and emergency lighting module must be observed as longer cable lengths might impair the function. We recommend: Distance EB <-> Emergency lighting module: 0.5 m Distance LLB <-> Emergency lighting module: 2.0 m
Specifications subject to alteration
273
Service
Luminaires for Fluorescent lamps with
electronic ballast ENERGY EFFICIENCY energy savings (25-30%) longer lamp life (approx. +50%)
EBs enhance the lighting quality Quick, silent and flicker-free start Constant, steady light No flickering electrodes No stroboscope effects Dimmable (dimmable EB)
ENVIRONMENT reduced energy consumption (25-30%)
Controllability, option for integration into control systems Automatic shutoff of defective lamps (no flickering) Automatic restart following lamp change
longer lamp life (approx. 50%) less lamp waste (approx. 30%)
EBs save energy and costs Low loss performance by EBs Low system power intake
system Most EB luminaires are suitable for direct current operation. They can be connected to the emergency lighting’s group and central battery systems.
High system light yield Longer (30-50%) service life of lamps Longer lamp replacement intervals Elimination of starters and capacitors Low heat generation Gentle warm start and high switching capacity of lamps Suitable as emergency lighting The „lamp plus EB“ system has a considerably reduced power intake and generates significantly less heat. EBs themselves generate little heat, thus reducing climate control measures – resulting in reduced operating costs for the air conditioning system. The service life of EB-operated lamps increases by 30-50 percent as a result of the reduced load on the lamp and electrodes. A three-band fluorescent lamp burns for 8,000 hours on an LLB compared to 14,500 operating hours on an EB. In addition to limiting the current, EBs also perform the task of starting and act as compensation condensers. Defective lamps are switched off automatically and do not flicker. Lamps are re-started automatically following replacement. EBs start the lamps quickly, silently and without any flickering. A warm start (pre-heated electrodes) protects the lamp and prolongs its service life. EBs developed specially for three-band, 16 mm diameter fluorescent lamps are equipped with cut-off technology that switches the coil heater off if permitted by the lamp operation. This increases the service life of the lamp by another 20 percent. In HF operation, the lamp voltage is smoother. Lamps operated on EBs therefore produce constant and steady light, with no flickering electrodes or stroboscope effects generated by moving parts. EBs are largely immune to voltage and frequency fluctuations. In addition, since most of them run on direct current, they can be switched to battery operation in the event of a power failure and used as emergency lights. If the EB malfunctions, it automatically disconnects itself from the mains.
274
Specifications subject to alteration
Service
Luminaires with
Light Emitting Diodes LED stands for light emitting diode, an electronic semi-conductor component. LEDs supply constant full-beam immediate light. Unlike incandescent lamps, LEDs do not radiate temperature. They emit light in a narrow spectral range and do not emit any infrared or ultraviolet radiation. LEDs have a high switching speed. The luminous flux is determined by the electrical current. As such, we recommend the use of a constant source of current. At the current state of development, the service life exceeds 50,000 hours and is dependent on various factors. Thanks to LED technology, the luminaire industry can design virtually maintenance-free luminaires. In summary, it is safe to say that LEDs will supersede incandescent lamps: Compared with conventional lamps, they consume less energy, generate less heat, are insensitive to shock, have considerably shorter switching times and a long service life.
ENERGY EFFICIENCY low power intake long service life â&#x2030;Ľ 50,000 hours
Future LEDs are the lamps of the future. Thanks to the numerous benefits, LED development is progressing at a phenomenal speed. RZB offers luminaires fitted with LED lamps for selected areas of application. These products can be identified by the symbol:
Specifications subject to alteration
275
Emergency Lighting | Article number coding Series: LED Halyxx® Type of protection: IP 40 Protection class: I Viewing distance: 14 m Ceiling thickness: 5-35 mm Wall thickness: 1-30 mm For escape route identification Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides. LED included. Please specify legend number when ordering! 14 m
Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS). Ballast mains/emergency: EB Available colours (X): 2 = white (only wall installation) 4 = aluminium, anodised (all variants)
Wall (surface)
Ceiling (surface)
Ceiling (recessed)
Wall (recessed) (cavity wall)
L
Ø4,5 23
L
B
3 15
180
12,5 12,5
LA L
50 50
40 40
150 150 233 233
151 233
H
B
45
15
5-35
H
H
B
55
L
HE
HA H
B
HA H
BA LA
LA
1-30
220 210
270 255
16 16 Ø5 Ø5
HE B
L
HE
Wall (recessed) (solid wall)
42
220 200
150
150
132
130
Viewing distance
Luminous flux factor
Lamp/Wattage
PZ 50 (.03)
MultiDigit (.04)
DALI (.07)
Rated operating time
Wall (surface)
14 m
-
4 x LED 1 W
•
•
-
3h
L 233, B 40, H 180
671502.00X.Y
Ceiling (surface)
14 m
-
4 x LED 1 W
•
•
-
3h
L 233, B 40, H 184
671518.00X.Y
Ceiling (recessed)
14 m
-
4 x LED 1 W
•
•
-
3h
671546.12X.Y
Wall (recessed) (cavity wall)
14 m
-
1 x LED 4 W
•
•
-
3h
671546.00X.Y
Wall (recessed) (solid wall)
14 m
-
1 x LED 4 W
•
•
-
3h
Article number
Type of installation
671501.00X.Y
Replace the X of the catalogue number with the desired colour. Example: Article number Article number with with X indication of colour 671501.00X 671501.004
Please add to the catalogue no., including the colour code, the code for any optional article (separated by a dot)
L 270, B 55, H 100 LA 255 x BA 42, HE 90 L 220, B 2, H 150 LA 210 x BA 132, HE 90 L 220, B 2, H 150 LA 200 x BA 130, HE 80
within the table • luminaire available with this module – luminaire not available with this module
.03 for PZ 50 .04 for MultiDigit® .07 for DALI Article number with indication of colour + Y 671501.004.Y
276
Dimensions
Article number with indication of colour and indication of optional article 671501.004.03
Specifications subject to alteration
Emergency Lighting | Motifs and lettering
Motifs for escape route identification â&#x20AC;&#x201C; BUILDING AND WORKPLACE LEGISLATION
Motifs for escape route identification â&#x20AC;&#x201C; WORKPLACE LEGISLATION
Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58
Legends in accordance with UVV BGV A8 and EECR 92/58
Background colour: green
Background colour: green
2003 Escape route to the right
1000 Escape route to the right
2113 Escape route to the upper right
1117 Escape route to the upper right
2114 Escape route to the lower right
1118 Escape route to the lower right
2004 Escape route to the left
1001 Escape route to the left
2115 Escape route to the upper left
1119 Escape route to the upper left
2116 Escape route to the lower left
1120 Escape route to the lower left
2005 Emergency exit, arrow pointing down
1002 Emergency exit, arrow pointing down
2006 Emergency exit, arrow pointing up
1051 Meeting point
1051 Meeting point 1166 Emergency exit, arrow pointing down
Please quote the motif numbers when ordering safety luminaires with legends. The size of the legend will be matched to the luminaire that you order. Luminaires with enclosed escape route motifs are supplied in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 (approved by building and workplace legislation). Please indicate the appropriate symbol numbers if you require delivery of other legends. The aspect ratios of the symbols for escape route identification comply with DIN 4844 and UVV BGV A8, i.e. square-shaped symbols have an aspect ratio of 1:1 and rectangular symbols of 2:1. In the case of luminaires with different dimensions, the remaining illuminated surfaces will be filled with opal.
1003 Escape route to the right 1113 Escape route to the upper right 1114 Escape route to the lower right 1004 Escape route to the left 1115 Escape route to the upper left 1116 Escape route to the lower left 1005 Emergency exit, arrow pointing down
Specifications subject to alteration
277
LUMINAIRE SIGNS | Motifs AND letterings
Notes for ordering legends and inscriptions Please always indicate the motif number or text when ordering luminaire signs with legends or inscriptions. The size of the legend or inscription will be matched to the luminaire that you order.
Motif
No.
Description
Motifs for numbers Background colour: blue (standard)
Motifs Please indicate motif number, e.g. 1019
Motif combinations Indicate the motif numbers from left to right, separated by a forward slash, e.g. 1019/1013
0001-0999 Numbers
Motifs for direction indicators Background colour: blue (standard)
1013 Arrow pointing right
EXIT Exit EXIT
Lettering Irrespective of their syntax, letterings are set in upper case, font: Helvetica Regular, e.g. EXIT. Please clearly order lower case if required, e.g. Lower case: Exit Other standard fonts: Helvetica Medium and Helvetica Bold. Other fonts are available at extra cost. e.g. Helvetica Medium: Exit, Helvetica Bold: Exit
1014 Arrow pointing left
1015 Arrow pointing down
1016 Arrow pointing up
1175 Arrow pointing left and up
EXIT
1176 Arrow pointing left and down
CONGRESS CENTER
Lettering comprising several lines Please specify the number of lines, e.g. two lines: CONGRESS CENTER
Negative imaging of motifs and lettering Quote the motif number (text or digits) and specify “inverse”, e.g. 1019/inverse
Single coloured motifs All motifs and lettering are mounted on a standard blue background. Other standard colours available at no extra cost: light blue, green, yellow, orange, red, grey Cover colours: silver, black Background colour: white/opal Quote the motif number (text or digits) and required colour(s), e.g. 1019/light blue / 1019/light blue/inverse
1177 Arrow pointing right and up
1178 Arrow pointing right and down
1163 Angled arrow pointing left and up
1164 Angled arrow pointing right and up
Motifs for general signs Background colour: blue (standard)
1017 Men‘s toilet
1018 Ladies‘ toilet
1019 Men‘s and Ladies‘ toilet
692
Numbers Include the catalogue number 0001-0999 e.g. 0692 / 0003
3
1021 Disabled toilet
1072 Restaurant
1073 Cafeteria
Special colours and fonts
1085 Hotel
Multicoloured motifs or lettering, customised motifs and special colours or motif/text/number combinations are available at extra cost.
1030 Cloakroom
Please do not hesitate to forward your request to our sales team. Provide them with details or even a drawing of the sign. We require a template in either .TIFF or .EPS format (or a hand drawing) in order to manufacture custom motifs.
1037 Stairway, up
1038 Stairway, down
1074 Lift
1033 Telephone
278
Specifications subject to alteration
LUMINAIRE SIGNS | Motifs AND letterings
Motif
No.
Description
1026 Information
1086 Arrivals
Motif
No.
Description
The aspect ratios of the symbols (fire protection and first aid, etc.) comply with the regulations specified in the European Directive (92/58/EEC) „Minimum requirements for the provision of safety and/or health signs at work“, i.e. square-shaped symbols 1:1 and rectangular symbols 2:1. In the case of luminaires with different dimensions, the left and right borders are filled in opal.
1089 Baggage collection
Motifs for fire protection facilities Legends in accordance with DIN 4844 and EECR 92/58 Background colour: red
1090 Luggage lockers
1057 Fire hose
1091 Taxi
1059 Fire extinguisher
1184 Railway station
1185 Tickets / Reservations
1186 Exchange/Bank/Cash dispenser
1187 Customs / Baggage control
1092 Car park
1024 Meeting point
1032 No smoking area Other motifs or customised designs are available on request. There may be an additional cost.
No.
Description
Motifs for prohibition signs Legends in accordance with DIN 4844 and EECR 92/58 Background colour: white; Symbol: black; Prohibition colour: red
1064 Smoking prohibited
1087 Departures
1088 Baggage drop
Motif
1060 Fire alarm 1061 Direction indicator, right 1062 Direction indicator, left
1065 Fire, open flames and smoking prohibited
1179 Restricted entry Other motifs or customised designs are available on request. There may be an additional cost.
Motifs for mandatory signs Legends in accordance with DIN 4844 and EECR 92/58 Background colour: light blue
1067 Eye protection mandatory
1063 Direction indicator, straight ahead 1068 Helmet mandatory Direction indicators only in combination with a symbol for a fire protection facility. Other motifs or customised designs are available on request. There may be an additional cost.
1069 Ear protection mandatory
1070 Protective gloves mandatory
Motifs for first aid facilities Legends in accordance with DIN 4844 and EECR 92/58 Background colour: green
Other motifs or customised designs are available on request. There may be an additional cost.
Legends in accordance with EECR 92/58, and/or DIN 1034 First aid station
40008 and DIN 25430. Background colour: yellow; Symbol: black
Motifs for sport facilities
1052 Stretcher
Background colour: blue (standard) 1053 Doctor
1162 Radioactive materials, ionising radiation
1075 Football 1054 Emergency telephone
1172 Laser beams
1093 Handball 1055 Eye-rinsing facility 1094 Volleyball 1084 Emergency shower 1095 Bowling
1173 Explosive gases Other motifs or customised designs are available on request. There may be an additional cost.
1009 Direction indicator, right 1010 Direction indicator, left
1079 Ice hockey 1056 Direction indicator, straight ahead 1078 Golf course
1077 Swimming
1076 Gymnastics
1080 Athletics
1096 Ballet
Direction indicators only in combination with a symbol for a first aid facility. Other motifs or customised designs are available on request. There may be an additional cost.
Any escape sign luminaire for central emergency power supply can also be ordered as luminaire sign. Plese see the section on luminiare signs of our current product selection guide.
1097 Riding
Specifications subject to alteration
279
lamps Design- nation/ Symbol
ZVEI- ILCOS- abbre- abbre- viation viation
Nominal Nominal Max. luminous wattage luminous flux intensitiy l [cd] [W] Φ [lm]
Beam angle [°]
Base
The specifications for the lamps used in the RZB catalogue are listed as neutrally as possible below. The lamp abbreviations are indicated in ILCOS and ZVEI LBS. The photometric values and bases for the lamps must be compared with the actual manufacturer’s specifications prior to incorporation in any light calculations or planning. The table lists the maximum values (luminous flux Φ and luminous intensity I) for many of the lamps. In the case of lamps for which just one manufacturer is known at present, the manufacturer is indicated as a footnote. Manufacturer codes: 1) Philips 2) Sylvania 3) Osram 4) GE 5) RZB 6) Venture Lighting 7) Narva 8) Megaman
Design- nation/ Symbol
ZVEI- ILCOS- abbre- abbre- viation viation
Nominal Nominal Max. luminous wattage luminous flux intensitiy l [cd] [W] Φ [lm]
Beam angle [°]
Base
Compact fluorescent lamp, long 18
1 200
2G11
24
1 800
2G11
36
2 900
2G11
40
3 500
2G11
55
4 800
2G11
80
6 000
2G11
28
2 800 2GX11
TC-L
TC-L
FSD
Compact fluorescent lamp, flat Incandescent lamp
A
18
1 100
2G10
A60 IAA
15
90
E27
24
1 700
2G10
25
220
E27
36
2 800
2G10
40
415
E27
TC-F
60
710
E27
75
935
E27
TC-F
FSS
Compact fluorescent lamp, square curved TC-DD
Compact fluorescent lamp, single tube TC
TC
FSD
5
250
G23
TC-DD
1 050
GR10q 4p
4)21
1 375
GR10q 4p
7
400
G23
28
2 050 GR8 2p
9
600
G23
28
2 050
11
900
G23
38
2 700
5
250
2G7
4)55
FSD
7
400
2G7
9
600
2G7
11
900
2G7
TC-D
FSQ
10
13
900 G24 d-1
18
1200 G24 d-2
T16/T26
GR10q 4p GR10q-3 4p
6
330
W4.3
8
540
W4.3
11
750
W4.3
13
930
W4.3
T16
FD-Ø16
4
140
G5
6
270
G5
26
1800 G24 d-3
8
450
G5
TC-DEL FSQH
10
600 G24 q-1
13
1 000
G5
13
900 G24 q-1
14
1 200
G5
18
1200 G24 q-2
21
1 900
G5
26
1800 G24 q-3
24
1 750
G5
28
2 600
G5
35
3 300
G5
39
3 100
G5
49
4 300
G5
54
4 450
G5
80
6 150
G5
10
650
G13
Compact fluorescent lamp, triple tube 13
900 GX24 d-1
18
1200 GX24 d-2
26
1800 GX24 d-3
TC-T
FSM
TC-TEL FSMH
13
900 GX24 q-1
18
1200 GX24 q-2
26
1800 GX24 q-3
32
2400 GX24 q-3
42
3200 GX24 q-4
T26
FDH-Ø16
FD-Ø26
15
950
G13
16
1 250
G13
18
1 350
G13
30
2 400
G13
T26-1m FD-Ø26-1m
36
3 100
G13
57
4300 GX24 q-5
70
5200 GX24 q-6
36
3 350
G13
38
3 300
G13
58
5 200
G13
TC-TEL FSMH
1)60
4000
2G8
1)85
6000
2G8
1)120
9000
2G8
FD-Ø26
Fluorescent lamp, ring-shaped
TC-TEL
22
1 800 2GX13
40
3 200 2GX13
55
4 200 2GX13
1)60
5 000 2GX13
T16-R
Compact fluorescent lamp, quadruple tube TC-QEL FSMH
4)57
4300 GX24q-5
4)70
5200 GX24q-6
T16-R
TC-QEL
FC-Ø16
Fluorescent lamp, ring-shaped Compact fluorescent lamp, Mikro-Lynx
280
FD-Ø7
600 G24 d-1
3 900
GR10q 4p
Fluorescent lamp
Compact fluorescent lamp, double tube
TC-FSE
1 050 GR8 2p
16
T7
TC-T
16
TC-EL
TC-D
FSS
TC-FSE FBC
2)6
220
GX53
8)7
220
GX53
8)9
360
GX53
8)13
520
GX53
T32-R
T29-R
FC-Ø29
22
1 250
G10q
T32-R
FC-Ø52
32
2 100
G10q
40
2 800
G10q
Specifications subject to alteration
Conditions of sale and delivery General: Unless explicitly agreed otherwise in writing, the following terms and conditions of sale apply, based on the „General Terms and Conditions of Supply“ for products and services supplied by the electrical industry. Special terms and conditions relate, above all, to export sales, which are based on the respective export terms as commonly applied. Our terms and conditions of delivery apply even if purchasers exclude the validity of the supplier’s terms and conditions of sale in their terms and conditions of purchase and we do not explicitly refute these. Verbal and/or special agreements are only binding if confirmed in writing by ourselves. Prices: The prices indicated in the price list are gross per unit ex factory, excluding value added tax, and are non-binding. The applicable prices on the day the order is received are used as the basis for calculation unless the order in question has, exceptionally, been explicitly confirmed at fixed prices. Value added tax will be charged separately at the applicable rate. Packaging: Packaging is charged at cost price. 2/3 of the calculated value of reusable packaging will be credited in the event of carriage paid returns. The same applies to container rent in the case of container shipment. Delivery: Prices are gross ex factory, excluding packaging, which will be invoiced at cost price. Orders for immediate delivery with a value of more than Euro 500 will be shipped carriage paid to the recipient’s railway station in Germany, excluding packaging; orders valued at EUR 1,000 net or more will be shipped carriage paid to the recipient’s railway station in Germany including packaging. Deliveries are shipped on the basis of freight collect; freight costs will be deducted from the invoice. If the value of an order entitles the purchaser to carriage paid shipment or carriage paid shipment including packaging, we reserve the right to ship parts of the order at a later date ex factory and excluding packaging if productionrelated issues prevent us from delivering these items immediately. Delivery times: Delivery times indicated in the order confirmations are largely adhered to; they are, however, not binding. We reserve the right to ship orders in parts. Any claims asserted on the grounds of delayed deliveries will not be admitted. Transfer of risk: The risk is transferred to the purchaser as soon as the shipment leaves our factory. The recipient bears the risk of transportation. Goods damaged in transit will not be reimbursed if breakage insurance of 1% of the net invoice amount is refused. Retention of title: Shipped goods remain our property until all outstanding claims against the purchaser have been met in full. The purchaser may use the goods that are subject to retention of title in the course of normal business operations. The purchaser is not permitted to pledge or transfer the goods by way of security or to assign them by any other means; we must be notified immediately of any seizures by third parties or other impairments of goods that are subject to retention of title. The purchaser already consents to assign any claims arising from the resale of goods subject to retention of title to the vendor and authorises the vendor to collect said claims. In spite of the aforementioned agreement, the purchaser remains authorised to collect any claims until we revoke such authorisation in writing. Upon our request, the purchaser must notify the debtor of the assignment of the claim. The vendor is entitled to give notice of this assignment. The reten-tion of title also extends to the full value of any products created by processing, blending or combining our goods. In this respect, we are deemed to be the manufacturer, and the purchaser shall exempt us from any obligations arising therefrom. In the event that third parties retain a right of title to goods used in the processing, blending or combination with our goods, we acquire co-title to the newly created products in the ratio of the invoice values of the processed goods. We are authorised to access the purchaser’s warehouse or to commission an agent to access the purchaser’s warehouse for the purpose of inspecting the goods that are subject to retention of title. We undertake to release the retention of title at our discretion if the value of the same exceeds the claims to be secured by 20%.
Specifications subject to alteration
Notification of defects: Complaints relating to shipped goods will only be considered if submitted within 8 days from receipt of the goods. The purchaser must provide proof to substantiate any complaint. In the event that we acknowledge the defect, we reserve the right to decide whether to accept the return of the defective merchandise in return for the revocation of the purchase contract or to replace it free of charge within a reasonable period or to credit the reduction in the value of the goods. Warranties for defects can only be accepted if such defects have demonstrably been caused by circumstances occurring prior to the transfer of risk. The warranty period is limited to a maximum of 12 months following the transfer of risk. We must be notified of any defects in writing as soon as they are detected. Returns will only be accepted if agreed in advance. Claims for damages asserted by the purchaser are excluded, irrespective of the legal grounds on which they are asserted and in particular in respect of any violations of contractual obligations and impermissible actions. This does not apply to statutory liability obligations, e.g. pursuant to the Product Liability Act, in cases of premeditation or gross negligence, if life, limb or health are threatened or material contractual obligations violated. Compensation for violations of material contractual obligations is, however, limited to the contract-specific, foreseeable damage unless such damage is caused by premeditation or gross negligence or liability must be assumed for injury to life, limb or health. The aforementioned regulations do not constitute a reversal of the burden of proof to the disadvantage of the purchaser. Returns: Purchasers may only cancel an order in part or whole with our prior consent. In such cases, we reserve the right to charge 30% of the value of the goods as partial reimbursement of our costs. Goods that have already been delivered may only be returned – if at all – in a re-sellable condition and in their original packaging. Custom-made products, luminaire signs and safety luminaires, merchandise procured at the request of the customer, incandescent and fluorescent lamps and electronic switching equipment may not be returned. In the event that we consent to the return, we will issue a return slip which must be included with the return. Standard and undamaged goods in original packaging will be credited at a maximum of 70% of the invoiced price. All reconditioning, freight and packaging costs must, moreover, be borne by the purchaser. Returns are always shipped at the risk of the customer returning the merchandise. No credit will be issued for goods returned without a written declaration of consent by RZB. Such goods may be disposed of at the sender’s expense. Weights, dimensions, technical specifications and illustrations have been prepared with all due care (E&OE) but are not binding since the construction, design and technical specifications of our products are constantly changing to keep pace with technical progress. Payment terms: Invoices are payable net and without any deductions within 30 days from invoice date. We grant a 2% discount on the net value of the merchandise if invoices are paid in advance or within 8 days from invoice date. In the event of delayed payment, we reserve the right to charge default interest at a rate of 5% above the applicable base rate pursuant to Section 1 Discount Rate Transition Act. A processing surcharge of Euro 10 will be levied on orders with a value of Euro 50 or less. In the event of default, the entire amounts receivable by us become due for payment immediately. Disposal: Non-private purchasers undertake to ensure the disposal of the purchased products in accordance with the provisions of the German Electrical and Electronic Equipment Act (ElektroG). In the event of resale, the purchaser transfers this obligation to their contractual partner. EU customers not resident in Germany: Please note the implementation of the WEEE Directive in national legislation. Place of performance and general court of jurisdiction for deliveries and payments and for all other obligations is, without exception, Bamberg. The General Terms and Conditions of Supply for products and services supplied by the electrical industry apply. Please do not hesitate to contact us if you require a copy.
281
Article number index
No. 09-6019.000 09-6202.009 09-6230.000 09-6284.000 09-6285.000 09-6286.000 09-6287.000 09-6288.000 09-6289.000 09-6290.000 09-6291.000 09-6292.000 09-6293.000 09-6294.000 09-6295.000
Page 117 151 151 115 115 115 115 115 115 115 115 115 115 115 115
22125.002 63, 197 22125.003 63, 197 65133 65936 65938 65940 65942
55 111 111 111 111
67000.0.152 67004.009 67005.009 67006.009
143 67 67 67
671001.752 671001.752.03 671001.752.04 671001.754 671001.754.03 671001.754.04 671003.752 671003.752.03 671003.752.04 671003.754 671003.754.03 671003.754.04 671005.752 671005.752.03 671005.752.04 671005.754 671005.754.03 671005.754.04 671009.752 671009.752.03 671009.752.04 671011.752 671011.752.03 671011.752.04 671013.752 671013.752.03 671013.752.04 671017.752 671017.752.03 671017.752.04 671023.752 671023.752.03 671023.752.04 671045.002
282
37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 43 43 43 43 43 43 43 43 43 42 42 42 42 42 42 45
No. 671045.002.03 671045.002.04 671045.004 671045.004.03 671045.004.04 671045.752 671045.752.03 671045.752.04 671045.754 671045.754.03 671045.754.04 671049.002 671049.002.03 671049.002.04 671049.004 671049.004.03 671049.004.04 671049.752 671049.752.03 671049.752.04 671049.754 671049.754.03 671049.754.04 671053.002 671053.002.03 671053.002.04 671053.004 671053.004.03 671053.004.04 671053.752 671053.752.03 671053.752.04 671053.754 671053.754.03 671053.754.04 671057.002 671057.002.03 671057.002.04 671057.004 671057.004.03 671057.004.04 671057.752 671057.752.03 671057.752.04 671057.754 671057.754.03 671057.754.04 671061.002 671061.002.03 671061.002.04 671061.004 671061.004.03 671061.004.04 671061.752 671061.752.03 671061.752.04 671061.754 671061.754.03 671061.754.04 671065.002 671065.002.03 671065.002.04 671065.004
Page 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46
No. 671065.004.03 671065.004.04 671065.752 671065.752.03 671065.752.04 671065.754 671065.754.03 671065.754.04 671069.002 671069.002.03 671069.002.04 671069.004 671069.004.03 671069.004.04 671069.752 671069.752.03 671069.752.04 671069.754 671069.754.03 671069.754.04 671073.002 671073.002.03 671073.002.04 671073.004 671073.004.03 671073.004.04 671073.752 671073.752.03 671073.752.04 671073.754 671073.754.03 671073.754.04 671077.002 671077.002.03 671077.002.04 671077.004 671077.004.03 671077.004.04 671077.752 671077.752.03 671077.752.04 671077.754 671077.754.03 671077.754.04 671081.002 671081.002.03 671081.002.04 671081.004 671081.004.03 671081.004.04 671081.752 671081.752.03 671081.752.04 671081.754 671081.754.03 671081.754.04 671085.002 671085.002.03 671085.002.04 671085.004 671085.004.03 671085.004.04 671085.752
Page 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47
No.
Page
671085.752.03 47 671085.752.04 47 671085.754 47 671085.754.03 47 671085.754.04 47 671089.002 47 671089.002.03 47 671089.002.04 47 671089.004 47 671089.004.03 47 671089.004.04 47 671089.752 47 671089.752.03 47 671089.752.04 47 671089.754 47 671089.754.03 47 671089.754.04 47 671093.752 109 671093.752.03 109 671093.752.04 109 671095.912 99 671095.912.03 99 671095.912.04 99 671107.912 671107.912.03 671107.912.04 671107.913 671107.913.03 671107.913.04 671109.912 671109.912.03 671109.912.04 671109.913 671109.913.03 671109.913.04 671111.752 671111.752.03 671111.752.04 671111.753 671111.753.03 671111.753.04 671112.922 671112.922.03 671112.922.04 671113.752 671113.752.03 671113.752.04 671113.753 671113.753.03 671113.753.04 671116.750 671148.000 671178.752 671178.752.71 671178.752.72 671178.752.81 671178.752.82 671178.754 671178.754.71 671178.754.72 671178.754.81 671178.754.82
107 107 107 107 107 107 107 107 107 107 107 107 63 63 63 63 63 63 99 99 99 63 63 63 63 63 63 67 16 169 169 169 169 169 169 169 169 169 169
No.
Page
671179.752 671179.752.71 671179.752.72 671179.752.81 671179.752.82 671179.754 671179.754.71 671179.754.72 671179.754.81 671179.754.82 671180.752 671180.752.71 671180.752.72 671180.752.81 671180.752.82 671180.754 671180.754.71 671180.754.72 671180.754.81 671180.754.82 671181.752 671181.752.71 671181.752.72 671181.752.81 671181.752.82 671182.752 671182.752.71 671182.752.72 671182.752.81 671182.752.82 671183.752 671183.752.71 671183.752.72 671183.752.81 671183.752.82 671184.752 671184.752.71 671184.752.72 671184.752.81 671184.752.82 671185.752 671185.752.71 671185.752.72 671185.752.81 671185.752.82 671186.752 671186.752.71 671186.752.72 671186.752.81 671186.752.82 671188.752 671188.752.71 671188.752.72 671188.752.81 671188.752.82
169 169 169 169 169 169 169 169 169 169 169 169 169 169 169 169 169 169 169 169 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 174 174 174 174 174 174 174 174 174 174 174 174 174 174 174
671207.002 671207.002.71 671207.002.72 671207.002.81 671207.002.82 671207.004 671207.004.71
177 177 177 177 177 177 177
No. 671207.004.72 671207.004.81 671207.004.82 671207.752 671207.752.71 671207.752.72 671207.752.81 671207.752.82 671207.754 671207.754.71 671207.754.72 671207.754.81 671207.754.82 671208.002 671208.002.71 671208.002.72 671208.002.81 671208.002.82 671208.004 671208.004.71 671208.004.72 671208.004.81 671208.004.82 671209.752 671209.752.71 671209.752.72 671209.752.81 671209.752.82 671209.754 671209.754.71 671209.754.72 671209.754.81 671209.754.82 671211.002 671211.002.71 671211.002.72 671211.002.81 671211.002.82 671211.004 671211.004.71 671211.004.72 671211.004.81 671211.004.82 671211.752 671211.752.71 671211.752.72 671211.752.81 671211.752.82 671211.754 671211.754.71 671211.754.72 671211.754.81 671211.754.82 671213.002 671213.002.71 671213.002.72 671213.002.81 671213.002.82 671213.004 671213.004.71 671213.004.72 671213.004.81 671213.004.82
Page 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177
Article number index
No. 671213.752 671213.752.71 671213.752.72 671213.752.81 671213.752.82 671213.754 671213.754.71 671213.754.72 671213.754.81 671213.754.82 671215.002 671215.002.71 671215.002.72 671215.002.81 671215.002.82 671215.004 671215.004.71 671215.004.72 671215.004.81 671215.004.82 671215.752 671215.752.71 671215.752.72 671215.752.81 671215.752.82 671215.754 671215.754.71 671215.754.72 671215.754.81 671215.754.82 671217.002 671217.002.71 671217.002.72 671217.002.81 671217.002.82 671217.004 671217.004.71 671217.004.72 671217.004.81 671217.004.82 671217.752 671217.752.71 671217.752.72 671217.752.81 671217.752.82 671217.754 671217.754.71 671217.754.72 671217.754.81 671219.752 671219.752.03 671219.752.04 671223.002 671223.002.71 671223.002.72 671223.002.81 671223.002.82 671223.004 671223.004.71 671223.004.72 671223.004.81 671223.004.82 671223.752
Page 177 177 177 177 177 177 177 177 177 177 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 42 42 42 178 178 178 178 178 178 178 178 178 178 178
No. 671223.752.71 671223.752.72 671223.752.81 671223.752.82 671223.754 671223.754.71 671223.754.72 671223.754.81 671223.754.82 671227.002 671227.002.71 671227.002.72 671227.002.81 671227.002.82 671227.004 671227.004.71 671227.004.72 671227.004.81 671227.004.82 671227.752 671227.752.71 671227.752.72 671227.752.81 671227.752.82 671227.754 671227.754.71 671227.754.72 671227.754.81 671227.754.82 671229.002 671229.002.71 671229.002.72 671229.002.81 671229.002.82 671229.004 671229.004.71 671229.004.72 671229.004.81 671229.004.82 671229.752 671229.752.71 671229.752.72 671229.752.81 671229.752.82 671229.754 671229.754.71 671229.754.72 671229.754.81 671229.754.82 671231.002 671231.002.71 671231.002.72 671231.002.81 671231.002.82 671231.004 671231.004.71 671231.004.72 671231.004.81 671231.004.82 671231.752 671231.752.71 671231.752.72 671231.752.81
Page 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179
No. 671231.752.82 671231.754 671231.754.71 671231.754.72 671231.754.81 671231.754.82 671233.002 671233.002.71 671233.002.72 671233.002.81 671233.002.82 671233.004 671233.004.71 671233.004.72 671233.004.81 671233.004.82 671233.752 671233.752.71 671233.752.72 671233.752.81 671233.752.82 671233.754 671233.754.71 671233.754.72 671233.754.81 671233.754.82 671235.002 671235.002.71 671235.002.72 671235.002.81 671235.002.82 671235.004 671235.004.71 671235.004.72 671235.004.81 671235.004.82 671235.752 671235.752.71 671235.752.72 671235.752.81 671235.752.82 671235.754 671235.754.71 671235.754.72 671235.754.81 671235.754.82 671236.912 671236.912.71 671236.912.81 671236.912.82 671237.912 671237.912.71 671237.912.81 671237.912.82 671238.912 671238.912.71 671238.912.81 671238.912.82 671247.912 671247.912.71 671247.912.72 671247.912.81 671247.912.82
Page 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179 185 185 185 185 185 185 185 185 185 185 185 185 197 197 197 197 197
No. 671247.913 671247.913.71 671247.913.72 671247.913.81 671247.913.82 671248.912 671248.912.71 671248.912.72 671248.912.81 671248.912.82 671248.913 671248.913.71 671248.913.72 671248.913.81 671248.913.82 671253.002 671253.003 671254.912 671254.913 671256.002 671256.004 671258.002 671258.004 671260.002 671260.004 671262.002 671262.004 671264.002 671264.004 671266.002 671266.004 671268.002 671268.004 671270.002 671270.004 671272.002 671272.004 671274.002 671274.004 671276.002 671276.004 671278.002 671278.004 671283.002 671284.002 671285.002 671286.002 671287.912 671287.912.71 671287.912.81 671287.912.82 671288.002 671289.912 671289.912.71 671289.912.81 671289.912.82 671290.752 671290.752.71 671290.752.72 671290.752.81 671290.752.82 671290.753 671290.753.71
Page 197 197 197 197 197 197 197 197 197 197 197 197 197 197 197 189 189 189 189 177 177 177 177 177 177 177 177 178 178 178 178 178 178 178 178 179 179 179 179 179 179 179 179 185 185 185 185 185 185 185 185 185 185 185 185 185 197 197 197 197 197 197 197
No.
Page
671290.753.72 671290.753.81 671290.753.82 671291.752 671291.752.71 671291.752.72 671291.752.81 671291.752.82 671291.753 671291.753.71 671291.753.72 671291.753.81 671291.753.82
197 197 197 197 197 197 197 197 197 197 197 197 197
671308.002 671309.912 671309.912.71 671309.912.81 671309.912.82 671311.752 671311.752.03 671311.752.04 671312.752 671312.752.71 671312.752.72 671312.752.81 671312.752.82 671315.000 671321.752 671321.752.03 671321.752.04 671343.002 671343.002.03 671343.002.04 671343.004 671343.004.03 671343.004.04 671343.752 671343.752.03 671343.752.04 671343.754 671343.754.03 671343.754.04 671347.002 671347.002.03 671347.002.04 671347.004 671347.004.03 671347.004.04 671347.752 671347.752.03 671347.752.04 671347.754 671347.754.03 671347.754.04 671351.002 671351.002.03 671351.002.04 671351.004 671351.004.03 671351.004.04 671351.752 671351.752.03
185 185 185 185 185 42 42 42 174 174 174 174 174 16 56 56 56 45 45 45 45 45 45 45 45 45 45 45 45 46 46 46 46 46 46 46 46 46 46 46 46 47 47 47 47 47 47 47 47
No. 671351.752.04 671351.754 671351.754.03 671351.754.04 671357.002 671357.004 671359.002 671359.002.71 671359.002.72 671359.002.81 671359.002.82 671359.004 671359.004.71 671359.004.72 671359.004.81 671359.004.82 671359.752 671359.752.71 671359.752.72 671359.752.81 671359.752.82 671359.754 671359.754.71 671359.754.72 671359.754.81 671359.754.82 671361.002 671361.004 671363.002 671363.002.71 671363.002.72 671363.002.81 671363.002.82 671363.004 671363.004.71 671363.004.72 671363.004.81 671363.004.82 671363.752 671363.752.71 671363.752.72 671363.752.81 671363.752.82 671363.754 671363.754.71 671363.754.72 671363.754.81 671363.754.82 671365.002 671365.004 671367.002 671367.002.71 671367.002.72 671367.002.81 671367.002.82 671367.004 671367.004.71 671367.004.72 671367.004.81 671367.004.82 671367.752 671367.752.71 671367.752.72
Page 47 47 47 47 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 177 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 178 179 179 179 179 179 179 179 179 179 179 179 179 179 179 179
283
Article number index
No. 671367.752.81 671367.752.82 671367.754 671367.754.71 671367.754.72 671367.754.81 671367.754.82 671368.752 671368.752.03 671368.752.04 671370.752 671370.752.03 671370.752.04 671372.002 671373.752 671373.752.71 671373.752.72 671373.752.81 671373.752.82 671374.912 671374.912.71 671374.912.72 671374.912.81 671374.912.82 671375.002 671376.752 671376.752.71 671376.752.72 671376.752.81 671376.752.82 671377.912 671377.912.71 671377.912.72 671377.912.81 671377.912.82 671378.002 671379.752 671379.752.71 671379.752.72 671379.752.81 671379.752.82 671380.912 671380.912.71 671380.912.72 671380.912.81 671380.912.82 671381.002 671382.752 671382.752.71 671382.752.72 671382.752.81 671382.752.82 671383.912 671383.912.71 671383.912.72 671383.912.81 671383.912.82 671384.002 671386.912 671386.912.71 671386.912.72 671386.912.81 671386.912.82
284
Page 179 179 179 179 179 179 179 51 51 51 51 51 51 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 183 190 190 190 190 190 190
No.
Page
671387.922 671387.922.71 671387.922.72 671387.922.81 671387.922.82
190 190 190 190 190
671422.912 671422.912.03 671422.912.04 671423.912 671423.912.03 671423.912.04 671425.912 671425.912.03 671425.912.04 671427.912 671427.912.03 671427.912.04 671446.752 671446.752.03 671446.752.04 671447.752 671447.752.03 671447.752.04 671455.962 671455.962.03 671455.962.04 671456.952 671456.952.03 671456.952.04 671466.009 671467.752 671467.752.03 671467.752.04 671493.982 671493.982.03 671493.982.04 671494.862 671494.862.03 671494.862.04 671495.962 671495.962.03 671495.962.04 671496.952 671496.952.03 671496.952.04 671497.982 671497.982.03 671497.982.04 671498.862 671498.862.03 671498.862.04
99 99 99 93 93 93 101 101 101 103 103 103 109 109 109 43 43 43 95 95 95 95 95 95 23 51 51 51 95 95 95 95 95 95 91 91 91 91 91 91 91 91 91 91 91 91
671501.004 671501.004.03 671501.004.04 671502.004 671502.004.03 671502.004.04 671503.004 671503.004.71 671503.004.72 671503.004.81 671503.004.82
29 29 29 29 29 29 163 163 163 163 163
No.
Page
671504.004 163 671504.004.71 163 671504.004.72 163 671504.004.81 163 671504.004.82 163 671515.752 58 671515.752.03 58 671515.752.04 58 671517.752 58 671517.752.03 58 671517.752.04 58 671518.004 29 671518.004.03 29 671518.004.04 29 671519.004 163 671519.004.71 163 671519.004.72 163 671519.004.81 163 671519.004.82 163 671520.002 56 671521.002 95 671521.002.03 95 671521.002.04 95 671531.952.1 89 671531.952.1.03 89 671531.952.1.04 89 671546.002 29 671546.002.03 29 671546.002.04 29 671546.004 29 671546.004.03 29 671546.004.04 29 671546.122 29 671546.122.03 29 671546.122.04 29 671546.124 29 671546.124.03 29 671546.124.04 29 671547.002 163 671547.004 163 671547.122 163 671547.124 163 671555.002 171 671555.002.71 171 671555.002.81 171 671555.002.82 171 671556.002 171 671556.002.71 171 671556.002.72 171 671556.002.81 171 671556.002.82 171 671557.002 171 671557.002.71 171 671557.002.81 171 671557.002.82 171 671558.002 39 671558.002.03 39 671558.002.04 39 671559.002 39 671559.002.03 39 671559.002.04 39 671560.002 39 671560.002.03 39
No.
Page
671560.002.04 39 671574.752 56 671574.752.03 56 671574.752.04 56 671585.862.1 89 671585.862.1.03 89 671585.862.1.04 89 671586.752 43 671586.752.03 43 671586.752.04 43 671587.962.1 89 671587.962.1.03 89 671587.962.1.04 89 671588.752 42 671588.752.03 42 671588.752.04 42 671590.752 41 671590.752.03 41 671590.752.04 41 671592.752 41 671592.752.03 41 671592.752.04 41 671594.752 41 671594.752.03 41 671594.752.04 41 671596.752 41 671596.752.03 41 671596.752.04 41 671597.752 173 671597.752.71 173 671597.752.72 173 671597.752.81 173 671597.752.82 173 671598.752 173 671598.752.71 173 671598.752.72 173 671598.752.81 173 671598.752.82 173 671599.752 173 671599.752.71 173 671599.752.72 173 671599.752.81 173 671599.752.82 173 671600.752 671600.752.71 671600.752.72 671600.752.81 671600.752.82 671601.002 671601.002.81 671601.002.82 671601.922 671601.922.71 671601.922.72 671601.922.81 671602.922 671602.922.71 671602.922.72 671602.922.81 671602.922.82 671605.922 671605.922.03
173 173 173 173 173 187 187 187 187 187 187 187 187 187 187 187 187 53 53
No. 671605.922.04 671606.922 671606.922.03 671606.922.04 671607.002 671607.002.71 671607.002.72 671607.002.81 671607.002.82 671608.752 671609.752 671609.752.03 671609.752.04 671611.000 671612.922 671612.922 671612.922.71 671612.922.71 671612.922.72 671612.922.72 671612.922.81 671612.922.81 671612.922.82 671612.922.82 671614.922 671614.922.03 671614.922.04 671615.002 671615.002.03 671615.002.04 671616.759 671616.759.71 671616.759.72 671616.759.81 671616.759.82 671617.759 671617.759.71 671617.759.72 671617.759.81 671617.759.82 671618.752 671619.752 671620.752 671629.752 671629.752.71 671629.752.72 671629.752.81 671629.752.82 671630.752 671630.752.71 671630.752.72 671630.752.81 671630.752.82 671639.752
Page 53 53 53 53 171 171 171 171 171 61 61 61 61 16 187 187 187 187 187 187 187 187 187 187 53 53 53 39 39 39 235 235 235 235 235 235 235 235 235 235 56 58 58 192 192 192 192 192 192 192 192 192 192 56
671700.342.1 671700.342.1.03 671700.342.1.04 671707.002 671707.002.03 671707.002.04 671717.752 671717.752.03
89 89 89 57 57 57 42 42
No.
Page
671717.752.04 42 671718.752 97 671718.752.03 97 671718.752.04 97 671719.752 97 671719.752.03 97 671719.752.04 97 671722.004 165 671722.004.71 165 671722.004.72 165 671722.004.81 165 671722.004.82 165 671735.922 105 671735.922.03 105 671735.922.04 105 671735.9231 105 671735.9231.03 105 671735.9231.04 105 671735.924 105 671735.924.03 105 671735.924.04 105 671736.004 164 671736.004.71 164 671736.004.72 164 671736.004.81 164 671736.004.82 164 671737.004 165 671737.004.71 165 671737.004.72 165 671737.004.81 165 671737.004.82 165 671738.004 164 671738.004.71 164 671738.004.72 164 671738.004.81 164 671738.004.82 164 671739.004 164 671739.004.71 164 671739.004.72 164 671739.004.81 164 671739.004.82 164 671740.004 165 671740.004.71 165 671740.004.72 165 671740.004.81 165 671740.004.82 165 671742.004 30 671742.004.03 30 671742.004.04 30 671744.004 31 671744.004.03 31 671744.004.04 31 671746.004 30 671746.004.03 30 671746.004.04 30 671748.004 31 671748.004.03 31 671748.004.04 31 671750.004 30 671750.004.03 30 671750.004.04 30 671752.004 31 671752.004.03 31
Article number index
No. 671752.004.04 671774.752 671774.752.71 671774.752.72 671774.752.81 671774.752.82 671775.002 671775.002.71 671775.002.72 671775.002.81 671775.002.82 671776.752 671776.752.71 671776.752.72 671776.752.81 671776.752.82 671777.862 671777.862.03 671777.862.04 671778.862 671778.862.03 671778.862.04 671779.862 671779.862.03 671779.862.04 671780.002 671780.002.03 671780.002.04 671781.002 671781.002.71 671781.002.72 671781.002.81 671781.002.82 671781.004 671781.004.71 671781.004.72 671781.004.81 671781.004.82 671782.002 671782.002.71 671782.002.72 671782.002.81 671782.002.82 671790.802 671790.802.71 671790.802.72 671790.802.81 671790.802.82 671790.804 671790.804.71 671790.804.72 671790.804.81 671790.804.82 671791.802 671791.802.71 671791.802.72 671791.802.81 671791.802.82 671791.804 671791.804.71 671791.804.72 671791.804.81 671791.804.82
Page 31 195 195 195 195 195 191 191 191 191 191 195 195 195 195 195 87 87 87 87 87 87 87 87 87 57 57 57 219 219 219 219 219 219 219 219 219 219 191 191 191 191 191 219 219 219 219 219 219 219 219 219 219 219 219 219 219 219 219 219 219 219 219
No.
Page
671792.002 671792.002.03 671792.002.04 671793.002 671793.002.71 671793.002.72 671793.002.81 671793.002.82 671799.802 671799.802.71 671799.802.72 671799.802.81 671799.802.82
59 59 59 193 193 193 193 193 219 219 219 219 219
671800.802 671800.802.71 671800.802.72 671800.802.81 671800.802.82 671801.002 671801.002.71 671801.002.72 671801.002.81 671801.002.82 671802.862 671802.862.03 671802.862.04 671803.862 671803.862.03 671803.862.04 671817.009 671819.002 671819.002.03 671819.002.04 671820.002 671820.002.71 671820.002.72 671820.002.81 671820.002.82 671822.002 671822.002.71 671822.002.71 671822.002.72 671822.002.81 671822.002.81 671822.002.82 671823.000 671824.009 671826.002 671826.002.71 671826.002.72 671826.002.81 671826.002.82 671835.002 671835.002.81 671835.002.82 671836.002 671837.002 671837.002.82 671838.002 671839.002 671839.002.82 671840.002
219 219 219 219 219 219 219 219 219 219 87 87 87 87 87 87 55 59 59 59 193 193 193 193 193 187 187 187 187 187 187 187 19 111 187 187 187 187 187 207 207 207 75 205 205 75 205 205 75
No.
Page
671841.002 205 671841.002.82 205 671842.0031 35 671843.0031 167 671843.0031.82 167 671846.0031 35 671847.0031 167 671847.0031.82 167 671854.002 207 671854.002.81 207 671854.002.82 207 671857.962 85 671857.962.03 85 671857.962.04 85 671858.952 85 671858.952.03 85 671858.952.04 85 671859.962 85 671859.962.03 85 671859.962.04 85 671860.952 85 671860.952.03 85 671860.952.04 85 671869.962 217 671869.962.71 217 671869.962.72 217 671869.962.81 217 671869.962.82 217 671870.952 217 671870.952.71 217 671870.952.72 217 671870.952.81 217 671870.952.82 217 671871.962 217 671871.962.71 217 671871.962.72 217 671871.962.81 217 671871.962.82 217 671872.952 217 671872.952.71 217 671872.952.72 217 671872.952.81 217 671872.952.82 217 671873.924 77 671873.924.03 77 671873.924.04 77 671874.964 77 671874.964.03 77 671874.964.04 77 671875.924 77 671875.924.03 77 671875.924.04 77 671876.964 77 671876.964.03 77 671876.964.04 77 671877.924 209 671877.924.71 209 671877.924.72 209 671877.924.81 209 671877.924.82 209 671878.964 209 671878.964.71 209 671878.964.72 209
No. 671878.964.81 671878.964.82 671879.924 671879.924.71 671879.924.72 671879.924.81 671879.924.82 671880.964 671880.964.71 671880.964.72 671880.964.81 671880.964.82 671881.834 671881.834.03 671881.834.04 671882.834 671882.834.03 671882.834.04 671883.834 671883.834.71 671883.834.72 671883.834.81 671883.834.82 671884.834 671884.834.71 671884.834.72 671884.834.81 671884.834.82 671885.822 671885.822.71 671885.822.72 671885.822.81 671885.822.82 671885.824 671885.824.71 671885.824.72 671885.824.81 671885.824.82 671886.842 671886.842.71 671886.842.72 671886.842.81 671886.842.82 671886.844 671886.844.71 671886.844.72 671886.844.81 671886.844.82 671887.832 671887.832.71 671887.832.72 671887.832.81 671887.832.82 671887.834 671887.834.71 671887.834.72 671887.834.81 671887.834.82 671888.822 671888.822.71 671888.822.72 671888.822.81 671888.822.82
Page 209 209 209 209 209 209 209 209 209 209 209 209 79 79 79 79 79 79 211 211 211 211 211 211 211 211 211 211 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 215 215 215 215 215
No.
Page
671888.824 671888.824.71 671888.824.72 671888.824.81 671888.824.82 671889.842 671889.842.71 671889.842.72 671889.842.81 671889.842.82 671889.844 671889.844.71 671889.844.72 671889.844.81 671889.844.82 671890.832 671890.832.71 671890.832.72 671890.832.81 671890.832.82 671890.834 671890.834.71 671890.834.72 671890.834.81 671890.834.82 671891.842 671891.842.03 671891.842.04 671891.844 671891.844.03 671891.844.04 671892.842 671892.842.03 671892.842.04 671892.844 671892.844.03 671892.844.04 671893.842 671893.842.03 671893.842.04 671893.844 671893.844.03 671893.844.04 671894.842 671894.842.03 671894.842.04 671894.844 671894.844.03 671894.844.04 671895.004 671895.004.03 671895.004.04 671896.004 671896.004.03 671896.004.04 671897.004 671897.004.03 671897.004.04
215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 215 81 81 81 81 81 81 81 81 81 81 81 81 83 83 83 83 83 83 83 83 83 83 83 83 30 30 30 30 30 30 30 30 30
671906.002 671906.002.03 671906.002.04 671907.002
59 59 59 59
No.
Page
671907.002.03 59 671907.002.04 59 671908.002 57 671908.002.04 57 671909.002 57 671909.002.04 57 671911.952.1 89 671911.952.1.03 89 671911.952.1.04 89 671912.004.03 31 671912.004.04 31 671913.004 31 671913.004.03 31 671913.004.04 31 671914.004 31 671914.004.03 31 671914.004.04 31 671915.004 33 671916.002 203 671917.002 73 671917.002.07 73 671918.002 73 671918.002.07 73 671919.002 199 671919.002.71 199 671919.002.72 199 671919.002.81 199 671919.002.82 199 671920.002 69 671920.002.07 69 671921.002 69 671921.002.07 69 671922.004 161 671922.004.71 161 671922.004.72 161 671922.004.81 161 671922.004.82 161 671923.004 161 671923.004.71 161 671923.004.72 161 671923.004.81 161 671923.004.82 161 671927.002 71 671927.002.07 71 671928.002 71 671928.002.07 71 671929.002 71 671929.002.07 71 671930.002 71 671930.002.07 71 671931.002 71 671931.002.07 71 671932.002 71 671932.002.07 71 671933.002 71 671933.002.07 71 671934.002 71 671934.002.07 71 671936.002 201 671938.004 161 671938.004.71 161 671938.004.72 161 671938.004.81 161
285
Article number index
No.
Page
671938.004.82 671939.004 671939.004.71 671939.004.72 671939.004.81 671939.004.82 671940.004 671940.004.71 671940.004.72 671940.004.81 671940.004.82 671941.004 671941.004.71 671941.004.72 671941.004.81 671941.004.82 671942.004 671942.004.71 671942.004.72 671942.004.81 671942.004.82 671943.004 671943.004.04 671943.004.07 671944.004 671944.004.04 671944.004.07 671945.004 671945.004.04 671945.004.07 671946.004 671946.004.04 671946.004.07 671947.004 671947.004.04 671947.004.07 671948.004 671948.004.04 671948.004.07 671949.004 671949.004.04 671949.004.07 671950.002 671950.002.71 671950.002.72 671950.002.81 671950.002.82 671951.002 671951.002.71 671951.002.72 671951.002.81 671951.002.82 671952.002.1 671952.002.1.71 671952.002.1.72 671952.002.1.81 671952.002.1.82 671952.002.2 671952.002.2.71 671952.002.2.72 671952.002.2.81 671952.002.2.82 671953.922
286
161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 201 201 201 201 201 201 201 201 201 201 221 221 221 221 221 221 221 221 221 221 225
No.
Page
671953.922.71 671953.922.72 671953.922.81 671953.922.82 671954.842 671954.842.71 671954.842.72 671954.842.81 671954.842.82 671955.952 671955.952.71 671955.952.72 671955.952.81 671955.952.82 671956.952 671956.952.71 671956.952.72 671956.952.81 671956.952.82 671957.002 671957.002.71 671957.002.72 671957.002.81 671957.002.82 671958.962.1 671958.962.1.71 671958.962.1.72 671958.962.1.81 671958.962.1.82 671958.962.2 671958.962.2.71 671958.962.2.72 671958.962.2.81 671958.962.2.82 671959.952.1 671959.952.1.71 671959.952.1.72 671959.952.1.81 671959.952.1.82 671959.952.2 671959.952.2.71 671959.952.2.72 671959.952.2.81 671959.952.2.82 671963.962 671963.963 671964.962 671964.9631 671964.964 671965.952 671965.9531 671965.954 671966.962 671966.9631 671966.964 671967.952 671967.9531 671967.954 671968.962 671968.9631 671968.964 671969.952 671969.9531
225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 223 223 223 223 223 223 223 223 223 223 223 223 223 223 223 223 223 223 223 223 231 231 229 229 229 229 229 229 229 229 229 229 229 229 229 229 229 229 229
No. 671969.954 671970.962 671970.9631 671970.964 671971.952 671971.9531 671971.954 671972.922 671972.923 671973.962 671973.963 671974.813 671974.813.71 671974.813.72 671974.813.81 671974.813.82 671975.912 671975.913 671975.919 671976.912 671976.913 671976.919 671977.0031 671977.004
Page 229 229 229 229 229 229 229 231 231 231 231 233 233 233 233 233 237 237 237 237 237 237 239 239
67923.750 67924.750
65 65
90-3757.002 90-3757.004 90-4013.002 90-4013.003 90-4164.002
37 37 63 63 56
98102.002/176 98102.002/215 981095.000 981098.002 981098.004 981098.0042 981098.005 981098.0061 981098.0076 981098.0082 981098.009
77 79 229 225 225 225 225 225 225 225 225
981100.002 981100.004 981100.0042 981100.005 981100.0061 981100.0076 981100.0082 981100.009 981127.003 981128.002 981129.002 981129.004 981129.0042 981129.005 981129.0061 981129.0076 981129.0082 981129.009
225 225 225 225 225 225 225 225 117 117 225 225 225 225 225 225 225 225
No.
Page
981144.002 981158.003 981158.003.03 981158.003.04 981159.003 981159.003.03 981159.003.04 981160.003 981160.003.03 981160.003.04 981161.003 981161.003.03 981161.003.04 981162.002 981162.002.03 981162.002.04 981163.002 981163.002.03 981163.002.04 981164.002 981164.002.03 981164.002.04 981165.002 981165.002.03 981165.002.04 981167.002 981168.002
56 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 41 37
981348.002 981352.003 981353.009
155 150 150
981485.002 981489.002
58 37
981502.000 981504.000 981506.000 981508.000 981510.000 981512.000 981581.004 981583.002 981586.002
118 118 118 118 118 118 29 58 169
981639.010 981639.020 981639.030 981639.040 981639.060 981640.000 981647.000 981647.010 981647.020 981647.030 981647.040 981653.002 981653.004 981653.102 981653.104 981656.000 981659.002 981659.004 981660.002 981660.004
29 163 29 29 163 31 165 31 165 31 31 77 77 77 77 77 79 79 79 79
No. 981662.000 981678.002 981678.004 981685.000 981686.000 981687.000
Page 79 213 213 29 30 31
981701.004 29 981702.004 31 981771.000 58 981781.000 56 981722.002 180 981722.002.71 180 981722.002.72 180 981722.002.81 180 981722.002.82 180 981723.002 180 981723.002.71 180 981723.002.72 180 981723.002.81 180 981723.002.82 180 981724.002 48 981724.002.03 48 981724.002.04 48 981725.002 180 981725.002.71 180 981725.002.72 180 981725.002.81 180 981725.002.82 180 981726.002 48 981726.002.03 48 981726.002.04 48 981727.002 180 981727.002.71 180 981727.002.72 180 981727.002.81 180 981727.002.82 180 981728.002 48 981728.002.03 48 981728.002.04 48 981734.000 85 981759.002 180 981759.002.71 180 981759.002.72 180 981759.002.81 180 981759.002.82 180 981760.002 180 981760.002.71 180 981760.002.72 180 981760.002.81 180 981760.002.82 180 981773.002 48 981773.002.03 48 981773.002.04 48 981774.002 48 981774.002.03 48 981774.002.04 48 981775.0031 35,167 981776.000 35,167 981777.0031 35 981777.0131 167 981777.0231 167 985019
156
No.
Page
985021 985054 985055 985107 985138 985147 985182 985195 985212 985213 985214 985215 985216 985217 985218 985238 985256 985272 985273 985274 985279 985280 985288 985289 985290 985291 985292 985293 985364 985366 985367 985368 985369 985370 985371 985372 985373 985374 985375 985377 985405 985406
156 157 157 124 149 149 157 156 143 143 143 143 143 143 143 124 149 152 153 153 154 154 134 134 134 135 135 135 149 139 139 139 139 139 139 139 139 139 139 139 11 11
991112 991116 991117 991118
61 53 53 53
99350 99350.1 99351
272 272 272
alphabetical Index
A No. Abbreviations
Page
No. 272
Absence of feedback
263
Accessories (overview)
148
all CPS and LPS systems
149-151
GV 1500
155-157
RZBeasy
155
LUXIFAIR
152-154
LUXIFAIRlight
152-154
Active star network
269
After sales service
289
Alphabetical index Alu-Lux oval
RZBbasic Page No. LUXIFAIR LUXIFAIRlight
128 Page 132 138
Charging and charge maintenance device
Alu‑Rund SC
106
CE
230
Andho (SC) TC
80
TC IP 65
82
Andho (CE) TC Flat
212
TC Flat IP 65
214
Anti-panic lighting
244
124
European and international regulations
242-246
EN 1838
242-243
Connecting diagrams
263
Connecting diagram for RZBeasy 202 / 204
147
Contact
289
Costs for weekly tests
261
DALI interface
10-13 242 242 242 40-43 172-175
Design of escape signs
262
154
recessed downlight (CE) 216
Die-cast aluminium (Alu-Druckguss)
Article number index
282
B Ballasts Basic
273 98
SC
28-31
CE
162-165
274
numbers
276
F SC
92
CE
224
Flat Basic with collar
94
236
Flat Polymero SC
88
CE
220 ®
Flat Polymero PC with collar
90
110
269
ECM module 152 (electric circuit module) 152
Information
273
Information and warning signs
96
CE
226
Flat Sign Mini/Midi SC
38
CE
170
246-269
Building permit
264
Building code
264
Electrotechnical safety
273
DIN VDE 0100, Part 560 263
Electrotechnical variants and additions
273
regulation)
265-266
LUXIFAIR
133
LUXIFAIRlight
139
RZBbasic
129
RZBeasy 202 / 204 EC module
145 137, 152
practices regulations)
RZBeasy 202 / 204
146
IO Module, Light switch setting sensor modules
153
IOM 230 for direct power supply voltage
153
IOM 24 for potential-free
BGV A8 (safe working 262
contacts
DIN VDE 0100, Part 718 263
K
DIN VDE 0108, Part 100 246
Kreis
DIN 4844, Part 1 / Part 2 262 (M) LAR - (Model) wiring systems directive
245
Installation example for
G
264
Group battery systems (LPS) Comparison
141
RZB GV 1500
142
RZBeasy 202 / 204
144
SC = Self-contained safety luminaires | CE = Luminaires for central emergency power supply
245
Installation example for
SC
ASR (workplace
Energo TC 175 recessed downlight (SC) 76 recessed downlight (CE) 208
166
(of batteries)
German regulations
118
34
CE
Inspections and controls
150 150 151 151
Emergency power supply unit PGVG 200
SC
222
Flat Polymero PC
Electronic switches UE220e UE220i Dimming mode Voltage control
Emergency conversion kits 116
Ilustris
222
Flat Polymero Rechteck E 30 junction box
I
®
Flat Polymero PMMA
®
E
charge maintenance device 130
®
124
Central battery systems (CPS) Comparison 127
safety spotlight
Housing with charging and
Flat Basic
Battery cabinets
204
H
Hand-held LED
Explanation of catalogue
143
CE
32
274
system (GV 1500)
74
GSUN® S
EB
273
SC
59
Halyxx®
General information
Centryxx
GSUN 4 LED
246
263
125
58
®
EN 60598-2-22
Electric circuits
operation rooms
57
®
245
244
and ventilation of electrical
GSUN® 3 LED
EN 50272-2
General
C
56
244
70 200
Calculating the aeration
GSUN® 3
245
124
Batteries for group battery
55
EN 50172
Edo SC CE
Batteries
GSUN 2 LED
GSUN 4
®
DUO Control
276
55 Page
®
Housing, fire-protected (E-30) 131
Definition Viewing distance Emergency lighting Legend (pictogram) Design SC CE
GSUN® 2 Page No.
EN 50171
EVG D
recessed downlight (SC) 84
(explanation)
265
Connecting diagrams 119-121
36 168
Article number codes
routes plan
Circuit identification signs 272
Display SC CE
Arelo®
recessed downlight (CE) 210 Escape and rescue
287 230
Energo TC 210 No. Page No. recessed downlight (SC) 78
153
100
L Lamps
280
LCS‑Z
194
LCS1
61
LCS3
61
287
Index
LED
275 ®
LED Halyxx
MultiDigit®
14-16
Multivariabel
SC
28-31
SC
50
CE
162-165
CE
182
MWEB
Legends (pictograms) Luminaire signs
278
Emergency escape luminaires
277
monitoring module
16-18
MWEBplus
18
luminaires
277
NCH complete
Legends for emergency escape
conversion kit
117
lighting
277
NCH module
117
Light Case
232
NCH safety conversion kit 117
Light switch setting sensor module (LSM)
157
Linear network
269
Luminance (of safety signs) 262 Light Case
232
Lucio
P PGVG 200
118
Planning issues
268
Printer
149
Protection types
272
SC
72
Protection classes
272
CE
202
Power supply units
116
Power sources
263
Luminaires for sports facilities
184
Luminaire signs
PZ 50
22-23
Legends (pictograms)
278
LUXIFAIR
132
Rechteck (Universal 2)
LUXIFAIR Master
136
Rechteck 250 / 360 / 485
LUXIFAIR sub distribution
86 218
Monitoring module CONTROL1
155
Monitoring via DALI interface
11-13
Motifs and letterings for luminaire signs
278-279
emergengy luminaires
288
277
244
Signal amplifier
16
SC
52
CE
186
SINGLE Control
154
Symbol explanations
273
W Weatherproof battens SC
108
CE
234
3 3-phase network monitoring module
149
Signcube SC
52
CE
186
SINGLE Control
154
Solyxx
206
Space
64
Starter set
16
Special requirements for battery rooms
245
T Technical support
188
289
SC
26
CE
160 263
47
244
CE
Servicing and testing
Turia
Log book
SC
273
46
Rechteck 250 / 360 / 485
Mondana
Safety marks
45
140
130, 140
244
Rechteck 360
LUXIFAIRlight Master
and monitoring unit
Visibility
Rechteck 250 Rechteck 485
Microprocessor control
110
Test logs
138
149
Safety‑Spotlights
44
LUXIFAIRlight
(surface mounting)
245
SC-overview 134
Message and switchboard
(concerning batteries)
Tenuo
R
board
M
262
Signcube N
Legends for emergency
Ventilation
S Safety and health signs
68
Turia Z
198
TWIN control for group battery
CE-overview
176
Rechteck 250
177
Rechteck 360
178
Rechteck 485
179
Remote control tableau,
system (GV 1500)
143
TWIN technology
155
U Universal 2
188, 189
type: MTB-BUS
156
Universal 3
188, 190
Rondo
102
Universal 3 LED
188, 191
Rounded Maxi
104
Universal 4
188, 192
Rounded® extra flat
228
Universal 4 LED
188, 193
RZBbasic
128
Universal changeover unit, type: UUE 4/220
RZBbasic sub distribution board
131
RZBbasic components
130
RZBeasy 202 / 204
144
Universum
156 66
V Varioplast I SC
62
CE
196
SC = Self-contained safety luminaires | CE = Luminaires for central emergency power supply