SHEET INDEX Sheet Name
SHEET INDEX Sheet Number
BRASET SHOPHOUSE 3D VIEW G.F AND 1.F ROOF NORTH SOUTH VIEW EAST AND WEST VIEW SECTION VIEW G.F BATHROOM DETAIL 1.F BATHROOM DETAIL DR AND WDW SCHEDULE COLUMN BALUSTER BEAM SUPPORT COLUMN FACADE ELECTRIC G.F ELECTRIC 1.F 3D DETAIL PLUMBING PLUMBING SECTION PLBG G.F DETAIL PLBG G.F WATER PLBG SECTION WASTED PLBG SECTION DRAIN PLBG WATER SECTION FOOTING LAYOUT FOOTING RIEN COLUMN BASE AND G.F COLUMN 1.F COLUMN RIEN BEAM G.F 1.F BEAM ROOF BEAM RIEN SLAB G.F 1.F ROOF SLAB
SLAB RIENFORCEMENT STAIR STR RIEN
Sheet Number S111 S112 S113
1
3
G.F
2
1 : 110
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
3D View 2
E L A C S
GENERAL NOTES
3D View 1
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
A101 A102 A103 A105 A106 A107 A108 A109 A110 A111 B101 B101 B101 E101 E102 P100 P101 P102 P103 P104 P105 P106 P107 S101 S102 S103 S104 S105 S106 S107 S108 S109 S110
Sheet Name
D E R A P E R P . o N G N I W A R D
BRASET SHOPHOUSE
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I A101
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
1 : 110
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
1
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
2
PLUMBING 3D VIEW
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
STRUCTURAL FRAMING 3D
D E R A P E R P . o N G N I W A R D
3D VIEW
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
ORNG PHALLA F.B.I A102
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
12/12/18
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
1400 800
650
1600
1350
800
650
1600
2400
1600
650
0 5 . 0
800
H
H W1
1600
2850
W1
1600
1400
W1
1000
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
10 9 8 7 6 5 4 3 2 1
3700 700 200
3090
780
700 200
0 0 0 . 4 8 . 2 1
200
11 12 13 14 15 16 17 18 19 20
20 19 18 17 16 15 14 13 12 11
20 19 18 17 16 15 14 13 12 11
1 2 3 4 5 6 7 8 9 10
1000
1000
20 19 18 17 16 15 14 13 12 11
3090
G
900
915
200
1000
20 19 18 17 16 15 14 13 12 11
200 1000
905
3090
1000
905
3160
900
Bathroom G.F
900
700 200
3160
700 200
3160
2
2850
W1
0 8 . 3
0 0 0 . 4 8 . 2 1
1600
W1
0 8 . 3
G
0 4 . 4
A108
0 5 . 4
0 4 . 4
1
0 4 . 4
0 5 . 4
0 4 . 4
1 A108
11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10
10 9 8 7 6 5 4 3 2 1
2 A108 700
A108
F
600
F
2620
0 0 . 5 3600
0 0 . 5
E
E 3600
790
3600
790
0 1 . 1
W1
3600
705
5
1
7
Ground Floor
8
1000
800
6
1600
1000
800
1095
1600
630
8
1 : 100 DRAWING INFORMATION
D E R A P E R P D E K C E H C . o N G N I W A R D
G.F AND 1.F
D E I F I D O M E T A D
1 : 100 12/12/18 ORNG PHALLA F.B.I A103
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
800
First Floor
D E U S S I E T A D
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
770
7
E L A C S
ARCHITECT AND CONTRACTOR
1101
E L T I T G N I W A R D
GENERAL NOTES
1600
5
2
1 : 100
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
6
W1
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
8
7
6
5 5
1
8
Roof
Roof 7.20 m
1ST FLOOR
1ST FLOOR
3.70 m
3.70 m
G.F
G.F
0.20 m
0.20 m
South 1 : 100
D E U S S I E T A D
DRAWING INFORMATION
E L A C S
ARCHITECT AND CONTRACTOR
E L T I T G N I W A R D
E T A D
GENERAL NOTES
7
7.20 m
2
1 : 100
S N O I T P I R C S E D
. O N
. V E R
REVESION
North
6
D E R A P E R P . o N G N I W A R D
NORTH SOUTH VIEW
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I A106
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
1 : 100
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
Roof
Roof
7.20 m
7.20 m
---
1ST FLOOR
1ST FLOOR
3.70 m
3.70 m
---
G.F
G.F
0.20 m
0.20 m F.T -0.80 m
1
Section 1
2
1 : 100
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
1 : 100
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
Section 2
D E R A P E R P . o N G N I W A R D
SECTION VIEW
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I A108
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
1 : 100
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
905
1st Floor Slab
2125
Ceiling
905
450
660
1015
Door type D3
216
200
425
230
340
230
200
230
250
G.F Slab
1
1 : 25
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
BR G.F Detail
D E R A P E R P . o N G N I W A R D
G.F BATHROOM DETAIL
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I A109
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
1 : 25
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
H
Kitchen
Electric Symbol
G
Ceiling Light Ceiling Light Small Fluorescent Lamp Power Socket Light Switch Single
2
2 2
F
Light Switch Single 2 way Distribution Board
Living Room
2
Wall Lamp
Air Conditioner E
G.F ELECTRIC
1
1 : 80 5
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
8
E L A C S
GENERAL NOTES
7
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
6
D E R A P E R P . o N G N I W A R D
ELECTRIC G.F
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I E101
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
As indicated
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
1
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
2
PLUMBING 3D VIEW 1
PLUMBING 3D VIEW CLOSEUP
D E R A P E R P . o N G N I W A R D
3D DETAIL
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
ORNG PHALLA Checker P100
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
12/12/18
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
1
1
P102 P106 P105 P107
P102 P106 P105 P107 464
H 795
H
G
386
219
REF.
REF.
REF.
REF.
G
REF.
REF.
175
66
367
1406
171
264
2074
F
271
F 60 mmø
60 mmø 100 mmø 386 271 464
1000
E 1000
E
1700
199
1700
5
1
7
G.F PLBG WASTED
8
5
2
1 : 100
8
G.F PLUMBING DRAIN 1 : 100
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
7
E L A C S
GENERAL NOTES
6
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
6
D E R A P E R P . o N G N I W A R D
PLBG G.F DETAIL
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA Checker P103
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
1 : 100
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
1 P102 P106 P105 P107
65 mmø
1106
H
REF.
G
REF.
REF.
455
276
115
728
138
F
100 mmø
20 mmø 528
E
5
1
7
8
G.F PLBG WATER 1 : 100 DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
6
D E R A P E R P . o N G N I W A R D
PLBG G.F WATER
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA Checker P104
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
1 : 100
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
7Ø6-01-100
2 S102
8Ø16-03-
2 S102
2 S102
2 S102
7Ø6-01-100
3Ø16 S102 02
02 S102
9 3 2
4
Footing F2
3Ø16-028Ø16-03-
1
2
F2 SECTION
FOOTING REBAR SCHEDULE
3
1 : 20
F2 SECTION 1
Partition
Bar Diameter
F2
6 mm
01
7
4.80 m
160 mm 160 mm 58 mm
F2
16 mm
02
3
4.17 m
384 mm 700 mm 384 mm
1.556
12.96
F2
16 mm
03
8
8.16 m
400 mm 300 mm 400 mm
1.556
25.40
F2
16 mm
04
2
4.22 m
1.556
13.13
Mark Quantity
Total Bar Length
A
B
C
D
Bar Total Bar Mass(kg/m) Mass(Kg)
Shape Image
1 : 20
Column Footing
58 mm
0.00
1 : 10
1934 mm
216 mm
Grand total DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
51.50
D E R A P E R P . o N G N I W A R D
FOOTING RIEN
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I S102
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
As indicated
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
1Ø6-011ST FLOOR
200 100
3.70 m
3200
3500
3500 3200
Partition
Bar Diameter
C1 L1
16 mm
02
4
15.92 m
C1 L1
6 mm
04
24
16.45 m
160 mm 160 mm 58 mm
C1 L2
6 mm
01
1
0.69 m
160 mm 160 mm 58 mm
C1 L2
16 mm
03
4
14.25 m
C1 L2
6 mm
04
33
22.61 m
66
69.91 m
1Ø6-04-
1Ø6-04-
2
4
1 : 10
Bar Mass(kg/m)
Total Bar Mass(Kg)
1.556
24.77
58 mm
0
0.00
58 mm
0
0.00
1.556
22.17
0
0.00
D
Shape Image
3980 mm
3452 mm
150 mm
160 mm 160 mm 58 mm
58 mm
46.94
1ST FLOOR
C1 1.F 1 : 25
C1 L2 Section 1 : 10
DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
3
C1 L1 Section
C
3.70 m
0.20 m
1 : 25
B
33Ø6-04-100
22Ø6-04-150 G.F
1
A
500
500
Grand total
C1 G.F
Mark Quantity Total Bar Length
4 S105
33Ø6-04-100
4 S105
2 S105
22Ø6-04-150
2 S105
COLUMN REBAR SCHEDULE
Roof 7.20 m
200 100
1Ø6-04-
D E R A P E R P . o N G N I W A R D
COLUMN RIEN
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I S105
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
As indicated
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt
6
7
8
5 200
4200
200
1055
200
1855
7 2Ø16 S108 2 S108
1290
4300
200
1290
1720
1290
10 2Ø16 S108
6 2Ø16 S108
1 2Ø16 S108
200
4200
200
1290
200
1855
1055
6 2Ø16 S108
4 3Ø16 S108 11 2Ø16 S108
4 S108
3 S108
200
5
3
4
1
0 1 0 1 0 8 1 0 5 9 1
0 9
0 8 1 0 1 0 1 0 1
11Ø6-2-100 8 2Ø16 S108
200
3680
12Ø6-2-100
11Ø6-2-100
13Ø6-2-150 3 2Ø16 S108
520
200
540
3220
14Ø6-2-150
11Ø6-2-100
12Ø6-2-100
13Ø6-2-150
540
200
5 3Ø16 S108
520
3680
10Ø6-2-100 8 2Ø16 S108
200
B5-8/H
1
BEAM REBAR SCHEDULE
1 : 35
2Ø16-1-
8 1
8 1
Partition
Bar Diameter
Total Bar Length
A
B
B1 EL G.F
16 mm
1
2
23.97 m
238 mm
11788 mm
B1 EL G.F
6 mm
2
107
90.44 m
250 mm
150 mm
B1 EL G.F
16 mm
3
2
19.48 m
9610 mm
168 mm
1.556
30.31
B1 EL G.F
16 mm
4
3
6.95 m
239 mm
2118 mm
1.556
10.82
B1 EL G.F
16 mm
5
3
13.18 m
238 mm
4194 mm
1.556
20.50
B1 EL G.F
16 mm
6
4
11.12 m
2780 mm
1.556
17.30
B1 EL G.F
16 mm
7
2
2.71 m
1207 mm
1.556
4.22
B1 EL G.F
16 mm
8
4
15.32 m
3830 mm
1.556
23.84
B1 EL G.F
16 mm
10
2
6.44 m
3220 mm
1.556
10.02
B1 EL G.F
16 mm
11
2
2.71 m
1207 mm
1.556
4.22
131
192.32 m
Mark Quantity
C
D
Shape Image
Bar Mass(kg/m)
Total Bar Mass(Kg)
1.556
37.30
2Ø16-1-
2 1
8 1
200
2Ø16-72Ø16-8-
8 1
200
3
1 : 10
8 1
2 1
2Ø16-3-
B5-8/H 2-2
2
300
300
2 1
2Ø16-8-
2Ø16-3-
B5-8/H 3-3 1 : 10
2Ø16-1-
58 mm
58 mm
0.00
190 mm
8 1
300
2Ø16-6-
200 8 1
4
Grand total
B5-8/H 4-4
190 mm
158.53
1 : 10 DRAWING INFORMATION
D E U S S I E T A D
ARCHITECT AND CONTRACTOR
E L A C S
GENERAL NOTES
E L T I T G N I W A R D
E T A D
S N O I T P I R C S E D
. O N
. V E R
REVESION
2Ø16-3-
D E R A P E R P . o N G N I W A R D
BEAM RIEN
D E K C E H C
1. GENERAL NOTES APPLY TO ALL DRAWINGS 2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE ARCHITECT. 3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E. EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH WORK.
D E I F I D O M E T A D
12/12/18 ORNG PHALLA F.B.I S108
E L I F / H T A P
No. 1162, St 1007, Phnom Penh Tmey, Phnom Penh, Cambodia www.francebatimentindustire.com
As indicated
C:\Users\Sang_Lion\Desktop\14m structural drawing\14m Land.rvt