OZCO Project #342 - Patio Pergola
OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
1
16'0"
= (1'0")
= (1'0")
1 9'4 8 " 5 7'10 8 "
1 6'9 16 " 1 13'6 8 "
Overview-Front OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
3
16'0"
12'0" 6" typ
1'2" typ
6"
CL
Overview-Top OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
4
12'0"
7 1'7 8 "
1 10 4 "
9'0"
Overview-Right OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
5
Translucent OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
6
1
2
9
6
Bill of Material OZCO Project #342 - Patio Pergola
13
3
10
7
11
5
4
8
12
ITEM QTY. PART NO. NUMBER DESCRIPTION 6x6 Post Base 1 5 56608 Kit (6X6-PB-LS) 4" Flush Inside 2 2 56668 45 (FI45-LS-4) OWT Timber 3 12 56651 Bolt 8-10" 2" Timber Bolt Heavy Duty 12 56680 Washer (OWTTBW-2) 2" Standard 4 3 56617 Rafter Clip (RC-LS-2) OWT Timber 5 6 56651 Bolt 8-10" 8� Post to 6 1 56677 Beam Coupler (P2B-SB-LS) Post to Beam 7 4 56637 Bolt Inline (P2B-BI-LS) 6x6 8 5 Cedar 6x6x8'7 13/16" Post 2x10 9 4 2x10x8'0" Cedar Board 2x6 10 13 Cedar 2x6x12'0" Board 2x2 11 23 Cedar 2x2x16'0" Board 2x10 12 2 2x10x16'0" Cedar Board 6x6 13 6 6x6x3'0" Cedar Support
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
7
5 3 6 1 4
PART NUMBER 56608 56617 56651 56677 56637
6x6 Post Base (6x6-PB-LS) 2" Standard Rafter Clip (RC-LS-2) OWT Timber Bolt 8-10" 8� Post to Beam Coupler (P2B-SB-LS) Post to Beam Bolt Inline (P2B-BI-LS)
5 4 2 13 23
6x6x8L 2x10x8L 2x10x16L 2x6x12L 2x2x16L
6x6x8 2x10x8 2x10x16 2x6x12 2x2x16
QTY.
Material List OZCO Project #342 - Patio Pergola
DESCRIPTION
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/13/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/13/2018 . Please visit OZCOBP.com to get current information.
8
Suggested Tools (others may be required) OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
8
56651
56680 56608
56677
56637 56668 56617
OZCO OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
9
2x10 Cedar Board 8 with Decora cut
see template 1
see template 1
2x10 Cedar Board 16 with Decora cut both ends
2x6 Cedar Board 12 with Decora cut both ends
see template 2
2x2 Cedar Board 16 with chamfer on both ends 1 2 " X 45° both ends
Cutlist OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
10
1 22"
1 2"
1 R2 2 "
1 R4 2 "
SCALE 1 : 2
3 18" 7"
Template 1 OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
11
1 22"
1 R2 2 "
R3"
SCALE 1 : 2
3 4"
3 58"
Template 2 OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
12
1 13'6 8 "
13 16'2 16 "
Locate desired center of structure
9'0"
1 6'9 16 "
if site is not level, see Ozco Site Leveling instruction site plan OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
13
(Hex Cap Nut) provided Tool Required 3/8" Driver
(OWT Screw) provided
step 1 OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
14
(Hex Cap Nut) provided
2x10x16 Beams
Tool Required 3/8" Driver 2x10x8 Beams
(OWT Screw) provided
see "OverviewFront" page for Beam spacing
step 2 OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
15
Rafter
see "OverviewRight" page for Rafter spacing
step 3 OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
16
Purlin
secure with nails or screws
see "OverviewTop" page for Purlin spacing
chamfer facing down
step 4 OZCO Project #342 - Patio Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/27/2017 . This information is updated periodically and should not be relied upon after 2 years from 4/27/2017 . Please visit OZCOBP.com to get current information.
17