OZCO Project #324 - 12x16 Column Cap Pergola
OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
1
CL
8" spacing
16'0" beam & purlin CL
1" X 45°
15 2 16 " X 45°
12'0" rafter
3 3 4 " X 45°
8'0" post
3'0" support
1'4" spacing 1'0"
1'0"
1 8'1 16 "
1 13'7 8 "
1'0"
1'0"
9 9'5 16 " 1 9'6 2 "
Overview OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
3
10
6
8 9 2
4 11
5
3 7
1
Bill of Material OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
4
ITEM NO. 1
QTY. 4
PART NUMBER 51708
DESCRIPTION 6x6 Post Base (6x6-PB-IW)
2 3 4
2 8 4
51768 51786 51717
4" Flush Inside 45 (FI45-IW-4) 6x6 Post Band (6X6-BND-IW) 2" Standard Rafter Clips (RC-IW-2)
5
3
51738
2" High Velocity Rafter Clips (RC-IW-HV-2)
6
4
51779
6x6 Column Cap (6X6-CAP-IW)
7 8 9
4 6 11
6x6 Post 2x8 Board 2x6 Board
6x6x8'0" 2x8x16'0" 2x6x12'0"
10 11
17 4
2x4 Board 4x4 Support
2x4x16'0" 4x4x3'0"
Material List OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
5
51717 51738 51768 51708
51786
51779 OZCO Project #324 - 12x16 Column Cap Pergola
follow QR barcode with your smart phone or visit OZCOBP.com for product installation instructions V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
6
Suggested Tools (others may be required) OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
7
Laredo Sunset & Ironwood 2 great styles Same functionality choose your connection lifestyle both styles available for most products Laredo Sunset (566XX series)
Laredo Sunset & Ironwood
Ironwood (517XX series)
8
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
see Overview page for spacing
step 1 OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
9
see Overview page for spacing
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
step 2 OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
10
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
see Overview page for spacing
step 3 OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
11
Tool Required 1/4" Driver
Screw
see Overview page for spacing
step 4 OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
12
Tool Required 1/4" Driver
Screw
see Overview page for spacing
step 5 OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
13
space as desire
see Overview page for spacing
step 6 OZCO Project #324 - 12x16 Column Cap Pergola
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.
14