J0006090 ac brochure 01 11 17 ƒ (bro ac rlc1718)

Page 1

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS

BRO-AC-RLC1718


Panasonic Air Conditioning Designed To Care For You With more than 60 years of experience, exporting to more than 120 countries around the world, Panasonic is unquestionably a leader within the air conditioning sector. A world leader in innovation, the company has filed more than 91,539 patents to improve its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In all, the company has produced more than 200 million compressors and its products, particularly residential air conditioners, now hold the No. 1 market share in Japan, and other major countries in Asia. You can be assured of the extremely high quality of Panasonic’s air conditioners. This desire to excel has made Panasonic a world leader in air conditioning solutions. The company’s industrial capacity and firm commitment to the environment has enabled it to open new avenues of research and development of innovative technologies, enhancing its customers’ way of life. Panasonic offer a range of turnkey air conditioning solutions for homes and medium-sized buildings (such as offices and restaurants). These offer maximum effectiveness, comply with the strictest environmental standards and meet the most avant-garde construction requirements of our time. At Panasonic we know what a great responsibility it is to bring you the best solutions to your cooling and heating needs.

Exclusive Feature 1

Using sensors and precise control programs, ECONAVI analyses room conditions and adjusts cooling and heating power to reduce wasted electricity.

Exclusive Feature 2

nanoe™ X containing an abundance of OH radicals inhibits bacteria and viruses, deodorises unpleasant odours, and keeps the room’s air clean and healthy.

CONTENTS Introduction

02 - 03

Exclusive Features

04 - 09

Product Range

10 - 11

Outdoor Units

12 - 17

Indoor Units

Exclusive Feature 3

Deluxe Wired Remote Controller Features a large LCD display, touch keys for easy operation and multiple energy-saving functions.

2

Controllers

High Static Pressure Ducted type

18 - 23

Mid Static Pressure Ducted type

24 - 27

4-Way Cassette type

28 - 35

Under Ceiling type

36 - 39 40 - 47 3


Exclusive Feature 1

ECONAVI reduces inefficient air conditioning Providing outstanding energy-saving performance, Panasonic's air conditioners can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of a room. When unnecessary heating or cooling is detected, indoor units are individually controlled to match room conditions for energy-saving operation.

Detection of the level of activity enables optimum power saving

Sensors are remotely located to maximise the energy-saving effect

The presence or absence of people and level of activity within the room are detected in real time. Set temperature is automatically adjusted, optimising the power consumption.

When sensors are built into the indoor unit, pillars, walls, cabinets and other fittings can obstruct the sensors, reducing the area of detection and lowering the energy-saving effect. Panasonic sensors can be located anywhere in the room which enables the optimum layout for sensors in any location.

Case study at coffee shop

Under Ceiling

Mid Static Duct

Reduced cooling when tthere are fewer people

Applicable to all 4 types of indoor units*

40° -20°

20°

Wide 120˚

Detection area

Thorough cooling when there is a high level of activity

Approx 1m

A Automatic Thermo Off depending on conditions at tthe end of the day*

High Static Duct

60° -40°

2.5m

In the afternoon

At night A ECONAVI Sensor CZ-CENSC1

-60°

In the morning

4-way Cassette

1m 3m 5m 7m

Wide detection area

*Depending on conditions, the setting can change to Switch Off After 3 Hours, Thermo Off or Temperature Shift.

7m

Dead Zone

A sensor is remotely set to maximise the detection area. Installation flexibility ready for indoor unit layout changes.

*Except 18.0kW - 22.4kW

EXAMPLE 1

EXAMPLE 2

In a coffee shop power is adjusted to match the number of customers in each area.

In an apartment, power output is adjusted to match the number of people present in each room. Gentle cooling in areas of low activity

WALK-IN CLOSET MASTER A ER BEDROOM BATH

BALCONY

SEATING AREA

BEDROOM

COUNTER TABLE

: :

KITCHEN

Indoor units (3) Sensors (3) Thorough cooling in areas of high activity

BALCONY

Gentle cooling in areas of low activity

ENTRANCE

LIVING

Thorough cooling in areas of high activity :

4

Indoor units (3) : Grilles (3) Sensors (3) :

ENTRANCE

5


Exclusive Feature 2

Deluxe Wired Remote Controller Easy-to-use, with multiple energy saving functions at your fingertips.

Multiple control settings to meet a wide range of air conditioning needs Temperature Auto Return Even if you change the temperature setting, after a set time, it automatically returns to the original temperature setting. You can set the temperature auto-return time in 10-minute intervals, within a period of 4 hours.

Temperature Setting Range You can set the upper and lower temperature limits. Doing this helps reduce power consumption due to over cooling or heating. Setting is possible in the Cooling, Heating and Dry modes.

Auto Shutoff Air conditioning automatically stops after a set time, so you don’t have to worry about forgetting to switch the unit off. Even if you manually switch the unit back on after it has stopped, it automatically switches off again after the set time.

Wide range of controls for extra convenience Individual Louvre Control Lock individual flap (only for 4-way cassette U2 type) Each of the 4-directional outlets can be selected and locked to provide efficient air distribution that matches the indoor unit layout. Indoor units can be set individually.

CZ-RTC5A

Weekly Timer

1

Large 3.5" Full-dot LCD with White LED Backlight Characters and icons are clearly displayed for improved visibility. The display is also large enough to provide a wide range of information for easy confirmation of operation conditions.

6

2

Stylish, Easy-to-use Touch Key Design The elegant, flat design features large touch keys in a simple layout enabling easy, intuitive operation.

Allowing you to specify 8 Start/Stop times and temperature presets for each day of the week.

Service Contact Address Once you have registered your service contact details, they are automatically displayed if a problem with the air conditioner occurs. This assists you in quickly solving your service needs.

7


Exclusive Feature 2

Convenient controls Operation Lock

Maintenance Function

To prevent operation by anyone other than the supervisor, operation keys can be locked. This prevents unauthorised personnel from changing temperature settings, airflow rate, airflow direction and other settings.

Display of outdoor malfunction data, service contact details, filter cleaning remaining time and other data enables at-a-glance verification of maintenance information with the remote controller.

Filter Information

Repeat OFF Timer

Filter information is indicated for cleaning after a set time of operation period has passed. The number of hours can be adjusted.

You can stop the operation after a certain period of time each time operation is performed.

Quiet Operation Mode

Setting Lists

There’s a Quiet mode that reduces the outdoor unit’s operating noise. The mode can be switched On/ Off and Start/ End times can be set.

8

Function List

Information concerning current settings is displayed in the remote controller’s LCD for easy confirmation.

9


Panasonic provides ideal solutions for your air conditioning needs.

CAPACITY (kW)

6.0kW

Ducted

High Static Pressure Model

Indoor Unit

Page 18-21

for 6.0kW -16.0kW

Page 22-23

for 18kW - 22.4kW

7.1kW

10.0kW

12.5kW

14.0kW

16.0kW

18.0kW

20.0kW

S-160PE2R5A

S-180PE2R5B

S-200PE2R5B

18.0kW

20.0kW

S-60PE1R5A

S-71PE1R5A

S-100PE1R5A

S-125PE1R5A

S-140PE1R5A

S-60PF1R5A

S-71PF1R5A

S-100PF1R5A

S-125PF1R5A

S-140PF1R5A

S-60PU2E5A

S-71PU2E5A

S-100PU2E5A

S-125PU2E5A

S-140PU2E5A

S-125PT2R5A

S-140PT2R5A

22.4kW

S-224PE2R5B

ECONAVI ready

(Except for 18.0kW - 24.4kW

Ducted

Mid Static Pressure Model Page 24-27

ECONAVI ready

4-Way Cassette * Panel options (CZ-KPU3/CZ-KPU3A)

Page 28-35

ECONAVI ready

S-60PT2R5A

Under Ceiling Page 36-39

CAPACITY (kW)

Outdoor Unit 10

Page12-17

S-71PT2R5A

S-100PT2R5A

ECONAVI ready

6.0kW

U-60PE1R5A

7.1kW

U-71PE1R5A

10.0kW

U-100PE1R5A U-100PE1R8A*

12.5kW

14.0kW

16.0kW

U-125PE1R5A U-125PE1R8A*

U-140PE1R5A U-140PE1R8A*

U-160PE2R8A*

U-180PE2R8A*

22.4kW

U-200PE2R8A*

U-224PE2R8A*

(*3-phase)

11


Outdoor Unit

Outdoor Unit DC Inverter allows better comfort and energy savings.

6.0kW - 7.1kW

• Complies with all necessary Safety Approvals to ensure quality and safety • Top-class EER:4.27 / COP:5.00 (4 Way Cassette type:10.0kW) • Demand Response (DRED) compatible • Cooling operation is possible when outdoor temperature as high as 46°C • DC inverter technology combined with R410A for excellent efficiency

• Maximum piping length:75m (10.0kW-14.0kW) • Cooling operation is possible when outdoor temperature as low as -15°C • Heating operation is possible when outdoor temperature as low as -20°C • One ampere starting current • Auto restart from outdoor unit

Improved Energy Saving The operation efficiency has been improved using highly efficient R410A refrigerant, new DC inverter compressor, new DC motor and new design of heat exchanger.

Cooling (Ducted) 4.0

4

3

2

3.8

3.7

3.7

3.6

3.6

3.5

3.5

3.1

A large inverter compressor has been adopted, demonstrating superiority in performance with improved partial-load capacity.

2

Printed Circuit Board (S-LINK)

The number of PCB was reduced from 3 into 2 pieces to improve maintenance work.

3

DC Fan Motor

Checking load and outside temperature, the DC motor is controlled for optimum air volume.

New Large 4 Diagonal (520mm) Air Flow Fan

The newly designed fan has been developed to inhibit air turbulence and increase efficiency. As fan diameter has been increased to 520mm, the air volume has been increased, whilst maintaining a low level of sound.

High-Efficiency Heat Exchanger

The heat exchanger and the size of the copper tube in the heat exchanger has been redesigned to increase efficiency.

1

5

12

3.36 3.24

3.23

3.4

3.26

3.21

3.01

3.15

3.01

3.01

3.20

3.27

PE1

PE2

3.80

3.413.41

3.42

3.48 3.45

3.52

3.52 3.32

3.3

3.12

3.09

Previous

4.0

3.8

3.2

Compact & High Efficient Compressor

1

PE2

3.9

3.0

5

PE1

3.9

3.3

The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high COP value which ranked as one of the best in the industry. In addition, the use of highly efficient R410A refrigerant reduces CO2 emissions, and lowers operating costs.

Heating (Ducted) Previous

3.4

Energy-saving concept

16.0kW - 22.4kW

10.0kW - 14.0kW

3.37

3.52

3.54

16.0 kW

18.0 kW

3.60

3.34

3.2 3.1 3.0

2.9

2.9

2.77

2.8

2.8

2.7

2.7

6.0 kW

7.1 kW

10.0 kW

12.5 kW

14.0 kW

16.0 kW

18.0 kW

20.0kW

22.4 kW

6.0 kW

7.1 kW

10.0 kW

12.5 kW

14.0 kW

20.0 kW

22.4 kW

Wide Operating Range • Cooling operation is possible when outdoor temperature as low as -15°C • Cooling operation is possible when outdoor temperature as high as 46°C • Heating operation is possible when outdoor temperature as low as -20°C The remote controller temperature setting offers a range from 16°C to 30°C

Cooling: -15°C DB to 46°C DB Heating: -20°C WB to 24°C WB

13


both AS 4755 and AS 3823. Panasonic continues to design and develop products that are tailored to local needs and requirements. This ensures that the Panasonic products you are installing today are compliant with the demand response standards that are likely to be implemented in the near future. The Equipment Energy Efficiency (E3) program has been supporting the development of Demand Response Enabling Device (DRED) standards for airconditioners which should comply with AS 4755. DRED functionality is not compulsory today, however, this capability will be required for all installations in the very near future.

Outdoor Unit Product Quality and Safety

DRM1 DRM2 DRM3

Outdoor Unit

Demand controller

C

Terminal block Outdoor unit

Demand Response Compliant

DemandEnabling control terminal is available to complies control to Panasonic air conditioners are equipped with a Demand Response Device (DRED) which 0-50-75-100% of capacities. both AS 4755 and AS 3823. Panasonic continues to design and develop products that are tailored to local needs and requirements. This ensures that the Panasonic products you are installing today are compliant with the demand response standards that are likely to be implemented in the near future. The Equipment Energy Efficiency (E3) program has been supporting the development of Demand Response Enabling Device (DRED) standards for airconditioners which should comply with AS 4755. DRED functionality (6.0kW is not compulsory today, however, Dimensions – 7.1kW) this capability will be required for all installations in the very near future. 500 620

150

200 or more

or more

2-U shaped hole

1

Demand control terminal to control 31.5is available 61 57.5 0-50-75-100% of capacities.

380.5

Air intake

Air discharge

13

Enlarged view A

Refrigerant piping end connection

2-18x13 Anchor hole

Height difference *

5 41

340

47

6

8

7

51

40

30m

75.5

940

Anchor hole Terminal block

Space for Outdoor piping,wiring unitmaintenance and

18

41

340

A

Demand controller

C

Air intake 100 or more

170

Space for piping, wiring and maintenance DRM1 DRM2 DRM3

76

Adaptable to various building types and sizes Max. piping length : 50m (6.0kW, 7.1kW), 75m (10.0kW-14.0kW), 50m (16.0kW-22.4kW)

Unit:mm

35

Increased Piping Length for Greater Design Flexibility

300

All Panasonic air conditioners undergo strict quality and safety tests before sale. This rigorous process includes obtaining all necessary Safety Approvals, to ensure that all air conditioners we sell are not only built to exceed market standards, but are also completely safe.

13

60

4

35 Air discharge

120

Mounting hole, anchor bolt:M10 Refrigerant piping (liquid pipe),flared connection (ø9.52) 61 pipe),flared 57.5 Refrigerant31.5 piping (gas connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Enlarged view A Electrical wiring port (ø22) Refrigerant piping Electrical wiring port (ø27) Electrical wiring (ø35) end port connection

75.5

2-18x13 Anchor hole

76

430

84.5 109.5

1) 2) 3) 4) 5) 6) 7) 8)

5 41

unit: mm

View B

Space for piping,wiring and maintenance

B

64

90 Anchor hole

300

1

60 35 86

42

maintenance

200 or more

8

7

51

340

47

6

35

26

7 8

Air intake

40

940

4

380.5 120

8

48

81

7

41

98 kg

6

6 Air intake

Space for piping,

4wiring and

Unit:mm

18

340

5

Lightweight

462

2-U shaped hole

A

5

500 or more 100 48 120 or more 39 81

150

39

620

Handle

With a weight of only 98 kg (10.0kW, 12.5kW, 14.0kW), we have ensured that this unit is both easy to carry and install.

Air intake

3

170

Compact and Lightweight

16

Dimensions (6.0kW –2 7.1kW) Air discharge 996

*15m if the outdoor unit is below the indoor unit

68.5

Hole (Bottom)

173

62

2

Handle 5

14

6

7

8

4

26

60 35 86

120

16 39

64

28/09/2017 5:26 pm

unit: mm

View B

7 8

B

81

120

48

462

* 14.0kW or smaller capacity unit

430

* 14.0kW or smaller capacity unit

120

Quiet mode reduces outdoor operating sound by 5dB. External input signal is also available.

42 90

6 39

The slim and lightweight design can be installed in various environments.

4

5

81

Quiet Mode

Air intake

Air discharge

3

48

Compact & Flexible-design

Hole (Bottom)

996

2017-18 PAC Brochure 48pp 25-9.indd 15

15

68.5 173

62

60 84.5 109.5

35

4

1) 2) 3) 4) 5) 6) 7) 8)

Mounting hole, anchor bolt:M10 Refrigerant piping (liquid pipe),flared connection (ø9.52) Refrigerant piping (gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35)

15


Outdoor Unit

Outdoor Unit

940

1

13

380.5

160 230

660 200

1 2 3 4 5 6 7 8

160

160

350

A

Air-discharge

*1 (Gas piping connection) While the main gas side pipe is ø25.4, since connecting the outdoor unit's 3-way valve requires a ø19.05 flare, please be sure to use standard accessories joint piping B or A for connection (brazing), and connect as follows.

1

980

2-18x13 Anchor hole

370

980

340

40

75.5

41

Mounting hole (4-R6.5), anchor bolt : M10 Refrigerant tubing (liquid tube), flared connection (ø12.7) Refrigerant tubing (gas tube), flared connection (ø19.05)*1 Refrigerant tubing port Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35)

Specifi cation for pipe connecting indoor unit to outdoor unit.

13

4× 32 holes (holes for drain)

18

41

340

A

Air intake (10)

412.5

2-U shaped hole

150

Mounting hole, anchor bolt:M10 Refrigerant piping(liquid pipe),flared connection (ø9.52) Refrigerant piping(gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35)

20

620

1 2 3 4 5 6 7 8

36

170

Dimensions (16.0kW – 22.4kW)

370 330 170

Dimensions (10.0kW – 14.0kW)

2 Air intake

5 35

57.5

Enlarged view A Refrigerant piping end connection

4

42

64 90

Enlarged view B

Space for piping,wiring and maintenance

Air intake

47.5 Air discharge

50 62.5

Enlarged view A

16

39

48 121

82

200 or more Air intake

120

16

39

500 or more

7

100 or more

61

173

76 31.5

29

39 81

48

522

120

8

60

4

89

6

60

4

5

47

7

35

35

6

60 30

8

47

51

Anchor hole

36

B

unit: mm

51

5

unit: mm

35

8

8

16

4

7

7

173 120

8

6

4

16

7

60 84.5 109.5

75.5

6

60 35 86

26

B

6 35

5

7

300

5

48

81

120

39

490

6

8

5

121 48 82

Air discharge

12

3

3

1500

1416

2

Handle

Air intake

68.5

Hole (Bottom)

469

62

Air-discharge

42

74 100

4

Enlarged view B

17


High Static Pressure Ducted

Indoor Unit High Static Pressure

Ducted

High static and large airflow ducted for exceptional installation flexibility.

ECONAVI ready CZ-CENSC1

S-60PE1R5A S-71PE1R5A S-100PE1R5A

CZ-RTC5A

CZ-RTC4

S-125PE1R5A S-140PE1R5A S-160PE1R5A

Cold Drafts Reduced During Heating Operation

Compact Body Size Hidden in the ceiling, ideal for when interior decor is an important consideration such as in residences with many rooms and light commercial buildings.

1,100

• Accurate temperature measurement by E1/E2 sensor to reduce cold drafts during heating operation. 1,100

700

700 Air intake sensor E2 sensor E1 sensor

430

290 mm (60PE) 360 mm (71PE, 100PE)

60PE, 71PE, 100PE

System Example An inspection port (450 mm x 450 mm or more) is required at the control-box side of the indoor unit body.

125PE, 140PE, 160PE

Rectangle duct

Inspection port (450 x 450 mm or more)

18

Canvas duct

Intake grille

19


High Static Pressure Ducted

Indoor Unit

High Static Pressure

Ducted Dimensions

Optional Controller unit: mm

2.Gas side (O.D.ø15.88 FLARE, ø19.05 FLARE*)

model

A

B

C

D

S-60PE1R5A

130

33.1

290

118

S-71PE1R5A S-100PE1R5A

195

35.7

360

50

S-125PE1R5A S-140PE1R5A S-160PE1R5A

260

38.2

430

121.5

*Only for 16.0kW

2.Gas side (O.D.ø15.88 FLARE, ø19.05 FLARE*) *Only for 16.0kW

ECONAVI sensor CZ-CENSC1

3.Drain pipe size (O.D.ø32)

3.Drain pipe size (O.D.ø32) 1.Liquid side (O.D.ø9.52 FLARE)

1.Liquid side (O.D.ø9.52 FLARE)

Timer remote controller CZ-RTC4

14.0kW

6.0kW

7.1kW

10.0kW

S-60PE1R5A

S-71PE1R5A

S-100PE1R5A

S-100PE1R5A

S-125PE1R5A

S-125PE1R5A

S-140PE1R5A

S-140PE1R5A

S-160PE1R5A

Outdoor Unit

U-60PE1R5A

U-71PE1R5A

U-100PE1R5A

U-100PE1R8A

U-125PE1R5A

U-125PE1R8A

U-140PE1R5A

U-140PE1R8A

U-160PE2R8A

Phase/Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

3 Phase/ 50Hz

1 Phase/ 50Hz

3 Phase/ 50Hz

1 Phase/ 50Hz

3 Phase/ 50Hz

3 Phase/ 50Hz

V

230V | 240V

230V | 240V

230V | 240V

400V | 415V

230V | 240V

400V | 415V

230V | 240V

400V | 415V

400V | 415V

kW

6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0)

7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)

14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)

16.0 (5.4 - 18.0) 18.0 (5.6 - 20.0)

BTU/h

20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300)

24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)

47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)

54600 (18400 - 61400) 61400 (19100 - 68200)

W/W

3.24 : 3.41

3.23 : 3.48

3.36 : 3.52

3.36 : 3.52

3.21 : 3.37

3.21 : 3.37

3.15 : 3.52

3.15 : 3.52

3.09 : 3.52

kW

1.85 : 2.05

2.20 : 2.30

2.98 : 3.18

2.98 : 3.18

3.90 : 4.16

3.90 : 4.16

4.45 : 4.55

4.45 : 4.55

5.18 : 5.11

Power source

Cooling capacity : Heating capacity EER : COP Total power input

12.5kW

Wireless remote controller CZ-RWSK2 + CZ-RWSC3

Indoor Unit

Capacity Model Name

Deluxe Wired remote controller CZ-RTC5A

Cooling : Heating

16.0kW

Indoor Unit Current

Cooling : Heating

A

0.85 : 0.85 | 0.86 : 0.86

1.24 : 1.24 | 1.25 : 1.25

1.72 : 1.72 | 1.74 : 1.74

1.72 : 1.72 | 1.74 : 1.74

1.82 : 1.82 | 1.84 : 1.84

1.82 : 1.82 | 1.84 : 1.84

2.62 : 2.62 | 2.70 : 2.70

2.62 : 2.62 | 2.70 : 2.70

2.62 : 2.62 | 2.70 : 2.70

Dimensions

H×W×D

mm

290×1,100 (+100)×700

360×1,100 (+100)×700

360×1,100 (+100)×700

360×1,100 (+100)×700

430×1,100 (+100)×700

430×1,100 (+100)×700

430×1,100 (+100)×700

430×1,100 (+100)×700

430×1,100(+100) ×700

kg

35

42

44

44

48

48

53

53

53

L/s

366 : 366

500 : 500

666 : 666

666 : 666

833 : 833

833 : 833

1,000 : 1,000

1,000 : 1,000

1,000 : 1,000

Pa

70 (Max.100)

100 (Max.150)

100 (Max.150)

100 (Max.150)

100 (Max.150)

100 (Max.150)

100 (Max.150)

100 (Max.150)

100 (Max.150) 51 / 49/ 47 : 51 / 49/ 47

Net weight Air volume

Cooling : Heating

External static pressure Sound pressure level (H/M/L)

Cooling : Heating

dB(A)

43 / 41 / 40 : 43 / 41 / 40

45 / 44 / 43 : 45 / 43 / 44

48 / 46 / 44 : 48 / 46 / 44

48 / 46 / 44 : 48 / 46 / 44

49 / 47 / 45 : 49 / 47 / 45

49 / 47 / 45 : 49 / 47 / 45

51 / 49 / 47 : 51 / 49 / 47

51 / 49 / 47 : 51 / 49 / 47

Sound power level (H/M/L)

Cooling : Heating

dB(A)

60 / 58 / 57 : 60 / 58 / 57

62 / 61 / 60 : 62 / 61 / 60

70 / 68 / 66 : 70 / 68 / 66

70 / 68 / 66 : 70 / 68 / 66

71 / 69 / 67 : 71 / 69 / 67

71 / 69 / 67 : 71 / 69 / 67

73 / 71 / 69 : 73 / 71 / 69

73 / 71 / 69 : 73 / 71 / 69

73 / 71 /69 : 73 / 71 /69

3

3

3

3

3

3

3

3

3

mm

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

Number of fan speed Drain pipe size Outdoor Unit Current

Cooling : Heating

A

7.85 : 8.80 | 7.65 : 8.60

9.10 : 9.30 | 8.80 : 9.00

11.8 : 12.7 | 11.40 : 12.3

3.95 : 4.25 | 3.80 : 4.10

16.0 : 17.2 | 15.4 : 16.6

5.30 : 5.70 | 5.10 : 5.50

17.8 : 18.1 | 17.2 : 17.5

5.80 : 5.95 | 5.55 : 5.70

7.40 : 7.20 | 7.00 : 6.90

Dimensions

H×W×D

mm

996 × 940 × 340

996 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,500 × 980 × 370

kg

68

69

98

98

98

98

98

98

127

Net weight

20

Air volume

Cooling : Heating

L/s

1,000 : 1,000

1,000 : 1,000

1,833 : 1,583

1,833 : 1,583

2,166 : 1,833

2,166 : 1,833

2,250 : 2,000

2,250 : 2,000

2,733

Sound pressure level (Silent mode)

Cooling : Heating

dB(A)

48 (46) : 50 (48)

48 (46) : 50 (48)

52 (50) : 52 (50)

52 (50) : 52 (50)

53 (51) : 53 (51)

53 (51) : 53 (51)

54 (52) : 55 (53)

54 (52) : 55 (53)

59 (57) : 61 (59)

Sound power level (Silent mode)

Cooling : Heating

dB(A)

65 (63) : 67 (65)

65 (63) : 67 (65)

69 (67) : 69 (67)

69 (67) : 69 (67)

70 (68) : 70 (68)

70 (68) : 70 (68)

71 (69) : 71 (69)

71 (69) : 71 (69)

77 (75) : 79 (77)

Piping connections

Liquid/Gas

m

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø19.05

Pipe length

min. - max.

m

5 - 50

5 - 50

5 - 75

5 - 75

5 - 75

5 - 75

5 - 75

5 - 75

5 - 50

Elevation difference (OU located lower, OU located higher)

m

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

30,30

Maximum chargeless length

m

30

30

30

30

30

30

30

30

30

Refrigerant at shipping, Additional gas amount

g

R410A 2,000, 50 (g/m)

R410A 2,350, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 5,600, 50 (g/m)

Operation ranges

˚C

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

Cooling : Heating

21


High Static Pressure Ducted

Indoor Unit High Static Pressure

Ducted

High static and large airflow ducted for exceptional installation flexibility. CZ-RTC5A S-180PE2R5B S-200PE2R5B S-224PE2R5B

DC motor Self-diagnosing Function

Automatic Fan Operation

Mild dry

CZ-RTC4

Automatic Restart Function

Technical focus

Sensible cooling 5-10% improved

• Design flexibility thanks to high static pressure and large air volume • DC motor equipped • Low power input

• Discharge air temperature control to reduce cold drafts during heating operation • Configurable air temperature control

New heat exchanger with φ7mm pipe that increases the heat transfer surface to improve sensible cooling (5-10% improvement)

Discharge air temperature control

3-step static pressure set up You can select between the three Static Pressure modes of 270 Pa / 140 Pa / 72 Pa for extra installation flexibility.

72Pa

140Pa

Factory Setting

• Equipped with 3 sensors (Air intake/ Coil sensors) • Possible to reduce cold drafts during heating operation.

270Pa

Max. 270 Pa static pressure setting

E2 sensor

Air intake sensor

E1 sensor

A maximum static pressure setting of a high 270 Pa enables the use of long ducts for installation in a wide range of spaces. Ideal for large-scale offices, restaurants and other facilities. Capacity Model Name

Indoor Unit Outdoor Unit Phase/Hz

Power source

V kW

Cooling capacity : Heating capacity

BTU/h

EER : COP Total power input

Cooling : Heating

18.0kW

20.0kW

22.4kW

S-180PE2R5B

S-200PE2R5B

S-224PE2R5

U-180PE2R8A

U-200PE2R8A

U-224PE2R8

1 Phase/ 50Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

230V | 240V

230V | 240V

230V | 240V

18.0 (5.4 - 20.0)

20.0 (6.3 - 22.4)

22.4 (6.3 - 25.0)

20.0 (5.6 - 22.4)

22.4 (7.1 - 25.0)

25.0 (7.1 - 28.0)

61400 (18400 - 68200)

68,200 (21,500 - 76,400)

76,400 (21,500 - 85,300)

68200 (19100 - 76400)

76,400 (24,200 - 85,300)

85,300 (24,200 - 95,500)

W/W

3.20 : 3.54

3.27 : 3.80

3.12 : 3.62

kW

5.63 : 5.65

6.12 : 5.90

7.18 : 6.90

Dimensions (18.0kW – 24.0kW)

Indoor Unit Current

Cooling : Heating

A

1.90 : 1.90 | 1.85 : 1.85

3.20 : 3.20 | 3.10 : 3.10

3.20 : 3.20 | 3.10 : 3.10

Dimensions

H×W×D

mm

479 × 1,453 × 1,205

479×1,453×1,205

479×1,453×1,205

kg

100

104

104

Cooling : Heating

L/s

933 / 850 / 733 : 933 / 850 / 733

1,200 / 1,050 / 883 : 1,200 / 1,050 / 883

1,200 / 1,050 / 883 : 1,200 / 1,050 / 883

Pa

60 (Max.270)

72 (Max.270)

72 (Max.270)

Sound pressure level (H/M/L)

Cooling : Heating

dB(A)

43 / 41/ 38 : 43 / 41/ 38

47 / 45 / 42 : 47 / 45 / 42

47 / 45 / 42 : 47 / 45 / 42

Sound power level (H/M/L)

Cooling : Heating

dB(A)

75 / 73 /70 : 75 / 73 / 70

79 / 77 / 74 : 79 / 77 / 74

79 / 77 / 74 : 79 / 77 / 74

Net weight Air volume External static pressure

Outdoor Unit Power source

3 Phase/ 50Hz

3 Phase/ 50Hz

3 Phase/ 50Hz,

400V | 415V

400V | 415V

400V | 415V

Current

Cooling : Heating

A

8.45 : 8.50 | 8.15 : 8.15

8.7 : 8.45 | 8.40 : 8.15

10.3 : 9.95 | 9.90 : 9.60

Dimensions

H×W×D

mm

1,500 × 980 × 370

1,500 × 980 × 370

1,500 × 980 × 370

kg

127

138

138

Cooling : Heating

L/s

2,733

2,667

2,667

Net weight Air volume

22

Phase/Hz V

Piping connections

Liquid / Gas

mm (inch)

Ø9.52 (3/8) / Ø19.05 (3/4)

Ø12.7(1/2) / Ø19.05 (3/4)*

Ø12.7 (1/2) / Ø19.05 (3/4)*

Pipe length

min. - max.

m

5 - 50

5 - 50

5 - 50

Elevation difference (OU located lower, OU located higher)

m

30,30

30, 30

30,30

Operation ranges

˚C

-15 to 46 : -20 to 24

-15 to 46: -25 to 24

-15 to 46 : -20 to 24

Cooling : Heating

* In the case of over 30m PIPE DIAMETER, please refer to technical documents for more details.

23


Mid Static Pressure Ducted

Indoor Unit Mid Static Pressure

Ducted

ECONAVI ready

Provides exceptional performance, super quiet operation and the ultimate in control. A perfect solution when ceiling heights are restricted.

S-60PF1R5A S-71PF1R5A

ECONAVI ready CZ-CENSC1

DC motor Self-diagnosing Function

Automatic Fan Operation

Mild dry

Automatic Restart Function

CZ-RTC5A

CZ-RTC4

S-100PF1R5A S-125PF1R5A S-140PF1R5A

Built-in Drain Pump

Technical focus • Space saving 290mm height • DC fan motor for variable external static pressure control • Easy to install and maintain

• Air off sensor avoids cold air drafts during heating operation • Configurable air temperature control

Built-in Drain pump (DC motor pump)

External electrical equipment box makes maintenance easy

Space saving height of 290mm for all models 290mm standardised height provides easy and uniform installation for models with different capacities, especially when ceiling heights are restricted.

Variable external static pressure control Optimal airflow set-up is possible for different ducting design and conditions.

• Built-in filter • Side removable filter

Optimal Control by DC Motor For short ducting such as hotels

10Pa

150Pa

For long ducting or for usage with high density filter Discharge air temperature control

* Please refer to technical databook for detail.

System example

Canvas duct

Rectangle duct

*Before spec-in, please consult with an authorised Panasonic dealer.

An inspection port (450 mm x 450 mm or larger) is required at the lower side of the indoor unit body. Intake grille

Inspection port (450 x 450 mm or more)

Air intake sensor E2 sensor E1 sensor

V-shaped heat exchanger To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area.

More powerful drain pump Using a high-lift built-in drain pump, drain piping can be elevated up to 702 mm from the base of the unit.

• Possible to control discharge air temperature for accurate room temperature control. • Possible to reduce cold drafts during heating operation.

Increases surface area Up to 300 mm Up to 500 mm 202 mm

24

25


Mid Static Pressure Ducted

Indoor Unit Mid Static Pressure

Ducted MID STATIC DUCTED Dimensions

Dimensions (10.0kW – 14.0kW) 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 flexible hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug (4-12 × 30 mm) 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for flexible air outlet duct 9 Electrical component box

6 32

6 172

7

Inspection access 450 x 450 (Field supply)

3

7

186

154

186

unit: mm

Min.400

Refrigerant tubing Min.650

Capacity

54

1192(Flange O.D.)

30 20 33 (150)

Refrigerant tubing

7.1KW

10.0KW

S-60PF1R5A

S-71PF1R5A

S-100PF1R5A

S-100PF1R5A

S-125PF1R5A

S-125PF1R5A

S-140PF1R5A

S-140PF1R5A

Outdoor Unit

U-60PE1R5A

U-71PE1R5A

U-100PE1R5A

U-100PE1R8A

U-125PE1R5A

U-125PE1R5A

U-140PE1R5A

U-140PE1R8A

Phase/Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

3 Phase/ 50Hz

1 Phase/ 50Hz

3 Phase/ 50Hz

1 Phase/ 50Hz

3 Phase/ 50Hz

V

230V | 240V

230V | 240V

230V | 240V

400V | 415V

230V | 240V

400V | 415V

230V | 240V

400V | 415V

kW

6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0)

7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)

14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)

BTU/h

20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300)

24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)

47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)

12.5KW

W/W

3.90 : 3.87

3.84 : 3.85

4.10 : 4.31

4.10 : 4.31

3.50 : 4.02

3.50 : 4.02

3.25 : 3.60

3.25 : 3.60

Cooling : Heating

kW

1.54 : 1.81

1.85 : 2.08

2.44 : 2.60

2.44 : 2.60

3.57 : 3.48

3.57 : 3.48

4.31 : 4.44

4.31 : 4.44

Current

Cooling : Heating

A

0.89 : 0.89 | 0.87 : 0.87

0.89 : 0.89 | 0.87 : 0.87

1.30 : 1.34 | 1.27 : 1.29

1.30 : 1.34 | 1.27 : 1.29

1.44 : 1.42 | 1.39 : 1.38

1.44 : 1.42 | 1.39 : 1.38

1.50 :1.50 | 1.47 : 1.46

1.50 :1.50 | 1.47 : 1.46

Dimensions

H×W×D

mm

290×1,000×700

290×1,000×700

290×1,400×700

290×1,400×700

290×1,400×700

290×1,400×700

290×1,400×700

290×1,400×700

kg

33

33

45

45

45

45

45

45

L/s

350 : 350

350 : 350

533 : 533

533 : 533

566 : 566

566 : 566

600 : 600

600 : 600

Pa

70 (10 - 150)

70 (10 - 150)

100 (10 - 150)

100 (10 - 150)

100 (10 - 150)

100 (10 - 150)

100 (10 - 150)

100 (10 - 150) 40 / 36 / 33 : 40 / 36 / 33

EER : COP Total power input

23

300

2

unit: mm

14.0KW

6.0KW

Cooling capacity : Heating capacity

140 186 290

Min.650

Indoor Unit

Power source

23 27

(75) 154

Electrical component box Inspection access 450 × 450

Indoor unit

77

min.250

636

792(Flange O.D.)

54

71

113 65

256 Min.250

290

(75)

Electrical component box

130 70

32

30 5

2

150

1400 1467(Suspension bolt pitch)

27

27

23

20-ø3holes 150 x 7 = 1050

186

140

8

1

77

33 (150)

300

113 65

256 30 20

1000 1067(Suspension bolt pitch)

71

70

23

27

Min.250

Min.400

636

21

Inspection access 450 × 450

Model Name

130

150

150 x 5 = 750

5

1

32

30

8

16-ø3holes

21

Indoor unit

4 89

89

min.250

26

700

4

636

26

700

636

700

758

280

Inspection access 450 x 450 (Field supply)

9

280

9 3

35

700

28

35

Filter

32

Filter

758

1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 flexible hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug (4-12 × 30 mm) 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 172 8 Flange for flexible air outlet duct 9 Electrical component box

28

Dimensions (6.0kW – 7.1kW)

Indoor Unit

Net weight Air volume

Cooling : Heating

External static pressure Sound pressure level (H/M/L)

Cooling : Heating

dB(A)

35 / 32 / 26 : 35 / 32 / 26

35 / 32 / 26 : 35 / 32 / 26

38 / 34 / 31 : 38 / 34 / 31

38 / 34 / 31 : 38 / 34 / 31

39 / 35 / 32 : 39 / 35 / 32

39 / 35 / 32 : 39 / 35 / 32

40 / 36 / 33 : 40 / 36 / 33

Sound power level (H/M/L)

Cooling : Heating

dB(A)

58 / 55 / 49 : 58 / 55 / 49

58 / 55 / 49 : 58 / 55 / 49

61 / 57 / 54 : 61 / 57 / 54

61 / 57 / 54 : 61 / 57 / 54

62 / 58 / 55 : 62 / 58 / 55

62 / 58 / 55 : 62 / 58 / 55

63 / 59 / 56 : 63 / 59 / 56

63 / 59 / 56 : 63 / 59 / 56

mm

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

VP-25

Drain piping Outdoor Unit Current

Cooling : Heating

A

7.40 : 7.10 | 8.40 : 8.10

8.60 : 9.50 | 8.30 : 9.20

10.60 : 11.20 | 10.30 : 10.70

3.53 : 3.70 | 3.43 : 3.58

15.90 : 15.80 | 15.30 : 15.10

5.29 : 5.26 | 5.12 : 5.05

19.30 : 19.10 | 18.60 : 18.40

6.42 : 6.35 | 8.18 : 6.15

Dimensions

H×W×D

mm

996 × 940 × 340

996 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

Net weight

26

kg

68

69

98

98

98

98

98

98

Air volume

Cooling : Heating

L/s

1,000 : 1,000

1,000 : 1,000

1,833 : 1,583

1,833 : 1,583

2,166 : 1,833

2,166 : 1,833

2,250 : 2,000

2,250 : 2,000

Sound pressure level

Cooling : Heating

dB(A)

48 : 50

48 : 50

52 : 52

52 : 52

53 : 53

53 : 53

54 : 55

54 : 55

Sound power level

Cooling : Heating

dB(A)

65 : 67

65 : 67

69 : 69

69 : 69

70 : 70

70 : 70

71 : 71

71 : 71

Piping connections

Liquid / Gas

m

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Pipe length

min. - max.

m

5 - 50

5 - 50

5 - 75

5 - 75

5 - 75

5 - 75

5 - 75

5 - 75

Elevation difference (OU located lower, OU located higher)

m

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

Maximum chargeless length

m

30

30

30

30

30

30

30

30

Refrigerant at shipping, Additional gas amount

g

R410A 2,000, 50 (g/m)

R410A 2,350, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

Operation ranges

˚C

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

Cooling : Heating

27


Indoor Unit / 4-Way Cassette

Indoor Unit

4-WAY Cassette

AIR INTAKE CHAMBER

nanoeX ready

1 1 2

2

Provides a neat fit in the ceiling to match modern decor, and uniform cooling throughout the room, plus easy installation.

3 3

ECONAVI ready

CZ-FDU3

[1] Air intake flange (Ø100) (field supply) Air intake box CZ-ATU2 * Air intake plenum CZ-FDU3 * When using Air intake box (CZ-ATU2), Air intake plenum (CZ-FDU3) is required.

PANEL

Self-diagnosing Function

Automatic Fan Operation

Mild dry

Intelligent Auto Swing

Automatic Restart Function

Auto Swing (Auto Flap Control)

Standard Panel: CZ-KPU3 ECONAVI Panel: CZ-KPU3A (Optional)

Built-in Drain Pump

Technical focus • Compact design • Low sound levels • DC fan motor for increased efficiency • Powerful drain pump gives 850 mm lift

• Lightweight design • Fresh air knockout • Branch duct connection • Optional air-intake plenum CZ-FDU3

360° Wide & Comfortable Airflow

Ample airflow: 36 m3/min

Industry’s leading in the 140PU class.

CZ-RTC4

The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter. (See ceiling height guidelines below.)

Comfort/Quiet

High Ceiling

(Factory settings)

3.6m

3.0m

New model

Capacity

60PU, 71PU

100PU, 125PU, 140PU

Industry’s top-class

360° Wide 1m

Simulation conditions: P140 4-way ceiling-mounted cassette type in cooling mode / Floor area of 225 m2/ Ceiling height of 3 m

3D Turbo Fan

Adding a sub flap and widening the main flap have reduced turbulence and increased airflow. Also, setting the jetting port at a wider angle allows the airflow to reach the corners of the room more quickly.

Using a twisted 3D blade made the unit slimmer and more compact, while also increasing the airflow. A 5-Speed mode allows the airflow to be adjusted in 5 steps to suit the situation.

Conventional

Conventional

Capacity

4-way discharge high ceiling settings2

3-way discharge

Previous flap

φ485

5 Speed Mode

Airflow increased

Sub Flap

28

Airflow turbulence is generated

Airflow turbulence is reduced

3

Twisted 3D Blade

3-way discharge (optional air- 2-way discharge (optional

Factory settings 1

High ceiling setting 1

High ceiling setting 2

60PU-71PU

3.0

3.3

3.6

3.8

4.2

100PU, 125PU, 140PU

3.6

3.9

4.5

4.7

5.0

Indoor unit

Φ490

with the optional air-blocking materials

Ceiling height guidelines

New Model

Width 70mm New flap

2-way discharge

with the optional air-blocking materials

*1 settings 4-way discharge

Width 48mm

5m

4.7m

4.5m

100PU-140PU

Wide Flap

New Model

CZ-RTC5A

S-125PU2E5A S-140PU2E5A

High-Ceiling Installation (Up to 5 m for 10.0kW+ models)

Our design features wide-angle outlets and flaps that were designed through expert mechanics and prototype tests. Air from the centre is spread further throughout the room. The air comes from all four sides of the unit and expands gently in a circle centred on the indoor unit.

Temperature distribution by thermograph (cooling operation)

CZ-CENSC1

S-60PU2E5A S-71PU2E5A S-100PU2E5A

blocking materials)

air-blocking materials) *2

*1 When using the unit in a configuration other than the factory settings, it is necessary to make settings on site to increase airflow. *2 Use air-blocking materials (CZ-CFU2) to completely block two discharge outlets for 2-way airflow.

5 29


Indoor Unit / 4-Way Cassette

Indoor Unit

4-way Cassette ( Optional) * CZ-KPU3A and CZ-RTC5A are required.

Humidity Sensor

ECONAVI, with a new humidity sensor, saves even more electricity In addition to detecting motion and floor temperature, humidity is also detected, making it possible to comfortably adjust the room temperature to match peoples’ movement and the room’s humidity.

Suits a maximum ceiling height of 5 m

Humidity Sensor

No. 1 in the industry

Detects humidity to further save electricity.

Floor Temperature Sensor

Motion Sensor

Field of view 1 m from the floor

[When People Are Slightly Active]

[ Temperature]

Low

[Humidity]

High Activity Amount (High, Medium) Cool EnergySaving Operation

Low Heat EnergySaving Operation

Ordinary Operation

The airflow direction is controlled to suit people's presence. Direct Airflow swings the airflow up and down in the area where people are present so the airflow contacts people directly. Indirect Airflow positions the flap horizontally to prevent the airflow from contacting people directly. The settings of these two patterns combine to control the airflow when people are present or absent.

[When Nobody Is Present]

Panasonic Original Technology

With 1 indoor unit installed

During preparation (Thermos OFF, Airflow ON)

When heating

Heat

Cool & Dry

Heat

Operates at a temperature lower than the set temperature.

Operates at a temperature higher than the set temperature.

Operates at the set temperature.

Cool & Dry

[Airflow Velocity] Automatic Airflow Velocity

[Remote Control Screen] [Circulation ON] is displayed

[Airflow Direction] Changes Automatically

Panasonic Original Technology

When absence continues for the preset time: Operates at the designated absence mode. When set by remote control: Operating time after absence detection (variable): 30 to 180 minutes (in 30-minute steps), 60 minutes [factory setting ( variable)]

30

Wind Screen

Heat

Operates at an even Operates at an even higher temperature lower temperature than when people than when people are in the room. are in the room.

Wind Contact When the absence of people is detected, circulation operation is activated. * Operation image

Circulation Operation

[Airflow Direction] Flap is horizontal for circulation operation

Furthermore, with 2 indoor units installed, when the absence of people is detected while the indirect Airflow setting is ON, circulation operation is automatically activated.

When heating Cool & Dry

Fixed Wind Screen

Fixed Wind Screen

Wind Screen

Operates at the set temperature.

Activity Amount (Low, Medium)

Airflow Control

The floor temperature sensor detects within the area of the motion sensor field of view

The Motion Sensor detects people's movement to cleverly save electricity.

[When People Are Very Active]

Even when activity is low, when the temperature is high the set temperature is lowered.

When the floor temperature sensor detects a low floor temperature during heating, a unique circulation flap operates to reduce the temperature gap between the ceiling and floor areas. This quickly and stably raises the temperature in the floor area.

Approx. 7 to 9 m

Motion Sensor

Heating

Circulation Control

Detection area of the motion sensor

Detection area of the floor temperature sensor

Cooling

Even when activity is high, when the temperature is low the set temperature is raised.

High

Mounting height 2.75 to 5 m

The average temperature of the floor surface is detected to determine the floor temperature condition.

Detects the movement of people to determine the amount of activity.

Energy-saving operation is controlled by the thermal sensation index.

Heating

When the absence of people is detected, circulation operation is activated.

Cooling

When the absence of people is detected, operation is activated for new circulation operation conditions to prevent drafts.

Heating

Circulation operation is activated regardless of whether people are present or absent.

Cooling

Circulation operation is not activated even if people are present, to prevent drafts.

31


Indoor Unit / 4-Way Cassette

Indoor Unit

4-way Cassette (Optional) * CZ-CNEXU1 and CZ-RTC5A are required.

nanoe X with Better Concentration The newly developed nanoe X device uses a counter electrode with four pins and a Multi-Leader Discharge that sends intensive discharges toward the pin tips. This expands the generation zone of electron-dense OH radicals, thus increasing the amount of OH radicals.

nanoe X keeps air conditioning and your air clean What’s nanoe?

Glow discharge Plasma region: Large

Discharge types

nanoe is a system that uses fine particle ions generated from moisture in the air to form tiny particles from electrically charged water molecules. Filled with OH radicals, these water capsules suppress the activity of pollen (allergens) in the air, and help to eliminate odours.

--OH-OH - -OH - -OH-OH -OH

Counter electrode Atomization electrode

Plasma region

Generation Principle: Moisture in the air is activated...

1

2

Dew condensation is collected on the pin tip,

3

High voltage is applied to the water, and

nanoe particles are generated

nanoe Airflow at a Comfortable Temperature • While working, you enjoy cooling or heating at a comfortable temperature, and a fresh breeze. • After work, when everyone is gone, ventilating operation continues to provide the nanoe effect. • You can start work each day in a room filled with refreshing air.

Invisible Air Contaminants Are Suppressed Pollen (allergens)

Odours

Mould

Bacteria

Viruses

nanoe particles are discharged from a single port, then carried and dispersed on the air conditioner's airflow.

Odours are suppressed The Interior Stays Clean with nanoe + Drying Control Allergens are suppressed

32

1

2

3

1

2

3

nanoe particles reach odours deep inside fabrics

OH radicals decompose odour-causing substances

Odours are eliminated

nanoe particles precisely reach allergens

OH radicals degenerate allergen proteins

Allergens are suppressed

After the Cool & Dry mode stops, a short ventilation operation is activated, and the indoor unit interior (heat exchanger, fan, air ducts) is dried and cleaned with nanoe particles. Turn on the fan, and Nanoe circulates internally

Sent air to inside

33


Indoor Unit / 4-Way Cassette

Indoor Unit

4-way Cassette X (Ceiling opening dimensions)

860~910

(390)

Refrigerant tubing (liquid tube) A ø9.52 (flared) / B 60 • 70 type ø9.52 (flared) Refrigerant tubing (gas tube) A ø15.88 (flared) / B 60 • 70 type ø15.88 (flared) Drain tube connection port VP25 (outer dia. ø32) Power supply port Discharge duct connection port (ø150)

Suspension bolt hole (4-12×30 elongated hole) Fresh air intake duct connection port (ø100) *

10 ECONAVI sensor (Only CZ-KPU3A)

51

143

184 124

Y

192

143

272

.

<Filter dimension> 520 x 520 x 15

A 256 B 319

143

4

840

115

Detailed view Y

7

64

480

(192)

View X

80

Over 30

2

16

134 515 (Air intake)

1

Over 18

850 mm

122

Up to

Less than 666

The drain height can be increased by approximately 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible.

A 124 B 187

115

2

105

7

2

2

4 - M4 Tapping screw holes

Z

2

35

3 11

View XX

Drain up

64

1

6

90

950 515 (Air intake)

143

2

33.5

Less than 35

7

32

90

105

Less than 300

Less than 850

A Drain Height of Approx. 850 mm from the Ceiling Surface

3

340

110

7

Less than 35

Up to 300 mm

Drain Pump of about 850 mm from the ceiling surface

Discharge outlet

* Necessary to

5

840 480 2

Protrusion of 33.5 mm

Air intake

50

One of the industry’s thinnest panels

The square panel integrates seamlessly with the ceiling. Discharge outlets close when the unit is stopped.

418

700

A 6.0 ~ 7.1kW B 10.0 ~ 14.5kW

(Suspension bolt pitch)

unit: mm

(Ceiling opening dimensions)

XX

780

(Suspension bolt pitch)

Low-Profile 33.5 mm Panel

1 2 3 4 5 6 7 8 9

860~910

(410)

The flap can be removed easily for cleaning.

Dimensions (6.0kW – 14.0kW)

Suction grill able to make 90 degree turns.

127

It is easy to remove the washable flaps by hand.

950

Easy Maintenance and Cleaning

80

4 - M4 Tapping screw holes

Detailed view Z

* Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more (18 mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible.

Capacity Model Name

6.0kW

7.1kW

10.0kW

12.5kW

Indoor Unit

S-60PU2E5A

S-71PU2E5A

S-100PU2E5A

S-125PU2E5A

Outdoor Unit

U-60PE1R5A

U-71PE1R5A

U-100PE1R5A

Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A

Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A

Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A

Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A

Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A

1 Phase, 50Hz

1 Phase, 50Hz

1 Phase, 50Hz

1 Phase, 50Hz

1 Phase, 50Hz

Panel Phase/Hz

Power source

Cooling capacity Heating capacity

U-100PE1R8A

U-125PE1R5A

14.0kW S-140PU2E5A U-125PE1R8A

U-140PE1R5A

U-140PE1R8A

V

230V | 240V

230V | 240V

230V | 240V

230V | 240V

230V | 240V

kW

6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0)

7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)

BTU/h

20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300)

24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)

EER : COP

Cooling : Heating

W/W

4.11 : 4.27

3.94 : 4.30

4.27 : 5.00

3.70 : 4.60

3.30 : 4.30

Total power input

Cooling : Heating

kW

1.46 : 1.64

1.80 : 1.86

2.34 : 2.24

3.37 : 3.04

4.24 : 3.72

Indoor Unit Cooling : Heating

A

0.35 : 0.34 | 0.34 : 0.33

0.39 : 0.38 | 0.38 : 0.37

0.79 : 0.78 | 0.76 : 0.75

0.88 : 0.87 | 0.85 : 0.84

0.94 : 0.93 | 0.91 : 0.90

Indoor

mm

256×840×840

256×840×840

319×840×840

319×840×840

319×840×840

Panel

mm

33.5×950×950

33.5×950×950

33.5×950×950

33.5×950×950

33.5×950×950

Indoor

kg

20

20

25

25

25

Panel

kg

5

5

5

5

5

Air volume

Cooling : Heating

L/s

250 / 266 / 216 : 250 / 266 / 216

366 / 266 / 216 : 366 / 266 / 216

600 / 433 / 300 : 600 / 433 / 300

616 / 450 / 316 : 616 / 450 / 316

633 / 483 / 333 : 633 / 483 / 333

Sound pressure level (H/M/L)

Cooling : Heating

dB(A)

36 / 31 / 28 : 36 / 31 / 28

37 / 31 / 28 : 37 / 31 / 28

45 / 38 / 32 : 45 / 38 / 32

45 / 39 / 33 : 45 / 39 / 33

47 / 40 / 34 : 47 / 40 / 34

Sound power level (H/M/L)

Cooling : Heating

dB(A)

51 / 46 / 43 : 51 / 46 / 43

52 / 46 / 43 : 52 / 46 / 43

60 / 53 / 47 : 60 / 53 / 47

61 / 54 / 48 : 61 / 54 / 48

62 / 55 / 49 : 62 / 55 / 49

5*

5*

5*

5*

5*

VP-25

VP-25

VP-25

VP-25

VP-25

Current Dimensions

H×W×D

Net weight

Number of fan speed Drain pipe size

mm

Optional Controller

ECONAVI sensor CZ-CENSC1

Deluxe Wired remote controller CZ-RTC5A

Timer remote controller CZ-RTC4

Wireless remote controller CZ-RWSU3

Outdoor Unit Current Dimensions

Cooling : Heating H×W×D

Net weight

6.80 : 7.40 | 6.60 : 7.20

8.10 : 8.25 | 7.90 : 8.00

10.1 : 9.70 | 9.70 : 9.40

996 × 940 × 340

996 × 940 × 340

1,416 × 940 × 340

3.45 : 3.30 | 3.35 : 3.20

14.7 : 13.3 | 13.3 : 12.9 1,416 × 940 × 340

5.00 : 4.50 | 4.80 : 4.35

18.6 : 16..3 | 18.0 : 15.8 1,416 × 940 × 340

6.30 : 6.10 | 5.50 : 5.35

kg

68

69

98

98

98

Air volume

Cooling : Heating

L/s

1,000 : 1,000

1,000 : 1,000

1,833 : 1,583

2,166 : 1,833

2,250 : 2,000

Sound pressure level (Silent mode)

Cooling : Heating

dB(A)

48 / - : 50 / -

48 / - : 50 / -

52 / - : 52 / -

53 / - : 53 / -

54 / - : 55 / -

Sound power level (Silent mode)

Cooling : Heating

dB(A)

65 / - : 67 / -

65 / - : 67 / -

69 / - : 69 / -

70 / - : 70 / -

71 / - : 71 / -

m

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

m

5 - 50

5 - 50

5 - 75

5 - 75

5 - 75

Elevation difference (OU located lower, OU located higher)

m

15, 30

15, 30

15, 30

15, 30

15, 30

Maximum chargeless length

m

30

30

30

30

30

Refrigerant at shipping, Additional gas amount

g

R410A 2,000, 50 (g/m)

R410A 2,350, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

Operation ranges

˚C

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

Piping connections Pipe length

34

A mm

min. - max.

Cooling : Heating

Please refer to technical documents for more details. *When using CZ-RTC5A, the number of fan speed will be 3 for other controller.

35


Indoor Unit / Under Ceiling

Indoor Unit

Under Ceiling Providing outstanding energy-saving performance, comfort and long-distance air flow distribution, these units are perfect for retail & education environments.

ECONAVI ready

S-60PT2R5A S-71PT2R5A

S-100PT2R5A S-125PT2R5A S-140PT2R5A

ECONAVI ready

CZ-CENSC1

Compact Looking, Stylish, One-Motion Design

Comfortable, Long-Distance Air Flow Distribution

With its streamlined, one-motion form, the unit looks thin and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while also keeping the unit clean.

The shape of the outlet has been optimised to provide long-distance air flow distribution. Even in long rooms, air flow reaches every corner for exceptionally comfortable air conditioning.

CZ-RTC5A

CZ-RTC4

Ceiling height

4.3m*

Energy-Saving Technology Delivering Top-Class Efficiency

Top Class Energy Saving

Air flow distance

13m*

Optimisation of the shape of the casing and fan assures bigger air flow and higher efficiency. Energy-saving performance is top class in the industry. New DC fan motor

Large Diagonal Air Flow Fan

* Results are based on specific testing conditions

High Ceiling Setting *Setting by remote control

DC motor 36

4.3m

Air flow distance 100

125

140

12m

13m

13m

Fan diameter

φ 147.5

37


Indoor Unit / Under Ceiling

Indoor Unit

Under Ceiling Dimensions (6.0kW – 14.0kW)

S-60PT2R5A S-71PT2R5A

1226 (Suspension bolt pitch)

Tubing hole position on wall surface (Figure shows view from front)

Capacity

3 4

Air discharge

Over 250

Over 250

1590

Service space

9 2

96

90 (Left drain position) (Closed with rubber stopper at time of shipment.)

86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position)

3 4

14.0kW

12.0kW

6.0kW

7.1kW

10.0kW

S-60PT2R5A

S-71PT2R5A

S-100PT2R5A

S-100PT2R5A

S-125PT2R5A

S-125PT2R5A

S-140PT2R5A

S-140PT2R5A

Outdoor Unit

U-60PE1R5A

U-71PE1R5A

U-100PE1R5A

U-100PE1R8A

U-125PE1R5A

U-125PE1R8A

U-140PE1R5A

U-140PE1R8A

Cooling capacity : Heating capacity

Phase/Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

1 Phase/ 50Hz

3-Phase/ 50Hz

1 Phase/ 50Hz

3-Phase/ 50Hz

1 Phase/ 50Hz

3-Phase/ 50Hz

V

230V | 240V

230V | 240V

230V | 240V

400V | 415V

230V | 240V

400V | 415V

230V | 240V

400V | 415V

kW

6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0)

7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)

14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0)

14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0)

BTU/h

20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300)

24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)

47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400)

47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400)

W/W

4.03 : 4.02

3.68 : 4.15

3.95 : 4.31

3.95 : 4.31

3.35 : 3.99

3.35 : 3.99

3.01 : 3.67

3.01 : 3.67

Cooling : Heating

kW

1.49 : 1.74

1.93 : 1.93

2.53 : 2.60

2.53 : 2.60

3.73 : 3.51

3.73 : 3.51

4.65 : 4.36

4.65 : 4.36

Current

Cooling : Heating

A

0.41 : 0.41 | 0.40 : 0.40

0.44 : 0.44 | 0.43 : 0.43

0.67 : 0.67 | 0.65 : 0.65

0.67 : 0.67 | 0.65 : 0.65

0.86 : 0.86 | 0.83 : 0.83

0.86 : 0.86 | 0.83 : 0.83

0.91 : 0.91 | 0.88 : 0.88

0.91 : 0.91 | 0.88 : 0.88

Dimensions

H×W×D

mm

235×1,275×690

235×1,275×690

235×1,590×690

235×1,590×690

235×1,590×690

235×1,590×690

235×1,590×690

235×1,590×690

kg

33

33

40

40

40

40

40

40

L/s

333 : 333

350 : 350

500 : 500

500 : 500

566 : 566

566 : 566

583 : 583

583 : 583

Pa

-

-

-

-

-

-

-

-

39 / 35 / 31 : 39 / 35 / 31

42 / 37 / 35 : 42 / 37 / 35

42 / 37 / 35 : 42 / 37 / 35

46 / 40 / 36 : 46 / 40 / 36

46 / 40 / 36 : 46 / 40 / 36

47 / 41 / 37 : 47 / 41 / 37

47 / 41 / 37 : 47 / 41 / 37

EER : COP Total power input

186

Tubing hole position on wall surface (Figure shows view from front)

Indoor Unit

Power source

80

Service space

216

216

90 (Left drain position) (Closed with rubber stopper at time of shipment.)

1 8 131 193 235

Air intake

6

216

4

5

Service space

2

690

176

186

Minimum 50cm

80

Approx. 2°

131 193 235 Over 250

1275

Service space

S-100PT2R5A S-125PT2R5A S-140PT2R5A

1584

176

Minimum 50cm

Over 250

9

Model Name

1 8

216

15

690

4

15 Approx. 2°

Air intake

Air discharge

Indoor Units:

1541 (Suspension bolt pitch)

1269

5

61

7

73

73

123

Indoor Units:

114

61

265 190 (Suspension bolt pitch)

123

7

114

Drain port VP20 (inside diameter ø26mm, drain hose supplied) Left drain position Refrigerant liquid tubing (ø9.52mm, flare connection) Refrigerant gas tubing (ø15.88mm, flare connection) Left side drain hose outlet port (cutout) Tubing hole on wall surface (ø100mm) Upper side tubing port Right side drain hose outlet port (cutout) Wireless remote controller receiver installation location

265 190 (Suspension bolt pitch)

1 2 3 4 5 6 7 8 9

6

96

86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position)

Optional Controller

ECONAVI sensor CZ-CENSC1

Deluxe Wired remote controller CZ-RTC5A

Timer remote controller CZ-RTC4

Wireless remote controller CZ-RWST3N

Indoor Unit

Net weight Air volume

Cooling : Heating

External static pressure Sound pressure level (H/M/L)

Cooling : Heating

dB(A)

38 / 34 / 30 : 38 / 34 / 30

Sound power level (H/M/L)

Cooling : Heating

dB(A)

56 / 52 / 48 : 56 / 52 / 48

57 / 53 / 49 : 57 / 53 / 49

60 / 55 / 53 : 60 / 55 / 53

60 / 55 / 53 : 60 / 55 / 53

64 / 58 / 54 : 64 / 58 / 54

64 / 58 / 54 : 64 / 58 / 54

65 / 59 / 55 : 65 / 59 / 55

65 / 59 / 55 : 65 / 59 / 55

3

3

3

3

3

3

3

3

mm

VP-20

VP-20

VP-20

VP-20

VP-20

VP-20

VP-20

VP-20

Number of fan speed Drain pipe size Outdoor Unit Current

Cooling : Heating

A

6.90 : 7.80 | 6.70 : 7.60

8.70 : 8.60 | 8.40 : 8.30

11.1 : 11.4 | 10.6 : 11.0

3.75 : 3.85 | 3.65 : 3.75

16.4 : 15.4 | 15.8 : 14.9

5.55 : 5.20 | 5.35 : 5.05

20.5 : 19.2 | 19.8 : 18.5

6.95 : 6.50 | 6.70 : 6.25

Dimensions

H×W×D

mm

996 × 940 × 340

996 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340

1,416 × 940 × 340 98

Net weight

38

kg

68

69

98

98

98

98

98

Air volume

Cooling : Heating

L/s

1,000: 1,000

1,000: 1,000

1,833: 1,583

1,833: 1,583

2,166: 1,833

2,166: 1,833

2,250: 2,000

2,250: 2,000

Sound pressure level

Cooling : Heating

dB(A)

48 : 50

48 : 50

52 : 52

52 : 52

53 : 53

53 : 53

54 : 55

54 : 55

Sound power level

Cooling : Heating

dB(A)

65 : 67

65 : 67

69 : 69

69 : 69

70 : 70

70 : 70

71 : 71

71 : 71

Piping connections

Liquid/Gas

m

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Ø9.52 / Ø15.88

Pipe length

min. - max.

m

5 - 50

5 - 50

5 - 75

5 - 75

5 - 75

5 - 75

5 - 75

5 - 75

Elevation difference (OU located lower, OU located higher)

m

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

15, 30

Maximum chargeless length

m

30

30

30

30

30

30

30

30

Refrigerant at shipping, Additional gas amount

g

R410A 2,000, 50 (g/m)

R410A 2,350, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

R410A 3,400, 50 (g/m)

Operation ranges

˚C

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

-15 to 46 : -20 to 24

Cooling : Heating

39


Controllers

Controllers A wide variety of control options to meet the requirements of different applications.

OPERATION SYSTEM Requirements

INDIVIDUAL CONTROL SYSTEMS

Advanced operation

Normal operation

CENTRALISED CONTROL SYSTEMS Operation from anywhere in the room

Operation with various functions from a central location

Only ON/OFF operation from a central location

Simplified load distribution ratio (LDR) for each tenant 10.4” touch screen panel colour LCD

NEW

Connection with 3rd Party Controller

Seri-Para I/O unit for outdoor unit

External appearance CZ-CAPDC2 Deluxe Wired Remote Controller

Timer Remote Controller (Wired)

Wireless Remote Controller

Type, model name CZ-RTC5A

CZ-RTC4

CZ-RWSU3 CZ-RWST3N

Built-in thermostat

l

l

ECONAVI ON/OFF control

l

Number of indoor units which can be controlled

Use limitations

CZ-RWSC3 + CZ-RWSK2

System Controller

ON/OFF Controller

Intelligent Controller

CZ-CENSC1

Interface Adaptor CZ-64ESMC3

CZ-ANC2

CZ-256ESMC3 (CZ-CFUNC2)

l

CZ-CAPC3

l

l

l

Seri-Para I/O unit for each indoor unit

1 group, 8 units

1 group, 8 units

1 group, 8 units

64 groups, max. 64 units

16 groups, max. 64 units

64 units x 16 systems, max. 256 units

· Up to 2 controllers can be connected per group (When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit)

· Up to 2 controllers can be connected per group (When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit)

· Up to 2 controllers can be connected per group.

· Up to 10 controllers, can be connected to one system. · Main unit/sub unit (1 main unit + 1 sub unit) connection is possible. · Use without remote controller is possible.

· Up to 8 controllers (4 main units + 4 sub units) can be connected to one system. · Use without remote controller is impossible.

· A communication adaptor (CZ-CFUNC2) must be installed for three or more links.

Air flow direction

l l l l l

l l l l l

l l l l l

l l l l l

l — — — —

l l l l l

Permit/Prohibit switching

l

l

l

Weekly program

l

l

l

l

Function ON/OFF Mode setting Fan speed setting Temperature setting

ECONAVI Sensor Utilises ECONAVI Sensor and Control Program technologies to detect where energy is normally wasted and self-adjusts cooling power to reduce energy wastage. • Activity detection • Absence detection

CZ-CAPBC2

Communication Adaptor CZ-CFUNC2

LonWorks Interface

CZ-CLNC2

All specifications are subject to change without notice.

40

41


Controllers

Individual Control Systems

Deluxe wired remote controller (CZ-RTC5A)

Control contents

Part name, model No.

Quantity

Standard Control • Control of the various operations of the indoor unit by wired or wireless remote controller. • Cooling or heating mode of the outdoor unit is decided by the first priority of the remote controller. • Switching between remote controller sensor and body sensor is possible.

Wired remoted controller CZ-RTC4 / CZ-RTC5A

1 unit each

(1) Group control • Batch remote control on all indoor units. • Operation of all indoor cells in the same mode. • Up to 8 units can be connected. • The sensor is the body sensor, and thermostat ON/OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit.

Wired remoted controller CZ-RTC4 / CZ-RTC5A

(2) Main/sub remote control • Max 2 remote controllers per indoor unit. (Main remote controller can be connected) • The button pressed last has priority. • Timer setting is possible even with the sub remote controller. When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit.

Main or sub Wired remoted controller CZ-RTC4 / CZ-RTC5A

Basic Operation

Wireless remote controller CZ-RWSU3 / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3

As required Dimensions H 120 x W 120 x D 16 mm

Wireless remote controller CZ-RWSU3 / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3

Energy Saving As required

Wireless remote controller CZ-RWSU3 / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3

• ECONAVI on/ off* • Temperature Auto Return • Temperature Setting Range • Auto Shutoff • Schedule peak cut • Repeat off timer

Backup control by using CZ-RTC5A group wiring of 2 systems of PAC. Auto individual control is possible. • Rotation operation • Backup operation • Support operation

SYSTEM EXAMPLE

• Individual Louver Control (Lock individual flap for 4-way cassette) • ON/ OFF timer • Weekly Timer • Filter information* • Outing function • Quiet operation mode* • Power consumption monitor* • Energy saving* • Initial settings • Ventilation

Maintenance Function

• Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information* • Service check • Simple/ Detailed Settings • Auto address *Depending on the model, some functions cannot be used.

Timer remote controller (CZ-RTC4) Weekly Programme Function

• A maximum of 6 settings/day and 42 settings/week can be programmed.

Outing Function

• This function can prevent the room temperature from dropping or rising when the occupants are out for a long time.

Sleeping Function Remote controller

Main

Sub

Main

Sub Dimensions H 120 x W 120 x D 20 mm

Standard control

(2) Main/sub remote control

(1) Group control

Basic remote controller ON/OFF

• Operation mode changeover (Cooling, Heating, Dry, Auto, Fan). • Temperature setting (Cooling/Dry: 18-30 deg Heating: 16-30 deg). • Fan speed setting H/ M/ L and Auto. • Air flow direction adjustment. • ECONAVI on/ off*

• This function controls the room temperature for comfortable sleeping.

Max. 8 indoor units can be controlled from one remote controller Remote control by main remote controller and sub controller is possible

Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. *Depending on the model, some functions cannot be used.

Time Function 24 hours real time clock • Day of the week indicator. 42

43


Controllers

Wireless remote controller Remote control by main remote controller and sub controller is possible

T10 Terminal for External Control (Digital Connection)

• Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. For 4-Way cassette type CZ-RWSU3

When CZ-RWSC3+CZ-RWSK2 is used, wireless control becomes possible for all indoor units

• When a separate receiver is set up in a different room, control from that room also becomes possible. • Automatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted.

Connecting an indoor unit to an external device is easy. The T10 Terminal featured in the electronic circuit board of all indoor units enables digital connection to external devices.

In addition, there are other functions such as temperature setting, operation switching, wind direction/fan speed setting, etc For all Ducted types CZ-RWSC3 +CZ-RWSK2

Ventilation independent operation is possible

When commercial ventilation fans or heat-exchange ventilation fans have been installed, they can be operated with this remote control (interlocked operation with the indoor unit or independent ventilation ON/OFF).

1. T10 Terminal Specification (T10:CN061 at indoor unit PCB) 1

For under ceiling type CZ-RWST3N

• ControlCOM items: 2 1. Start/stop input 3 2. Remote controller prohibit input 4 3. Start signal output +12V COM 5 4. Alarm signal output T10 (yellow)

1 COM 2 3

6

4 300msec. or more

T10 (yellow)

1-2 (pulse input)

ON

OFF

COM 5

Condition

+12

4-5 (output)

Unit condition

• Example of wiring

ON

NOTE: The wire length from indoor unit to the Relay must be within 2.0m. Pulse signal changeable to static with JP cutting. (Refer to JP001)

+12V

6

300msec. or more

1. 1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal. (1 1-2pulse (pulse input) signal: shortage status more than 300msec.or more) 2. 2-3 (Static input): Open/ Operation with Remote is permitted.(Normal condition) Close/ Remote controller is prohibited. +12 the unit ON. / No output at OFF. 3. 4-5 (Static output): 12V output during 4-5 (output) 4. 5-6 (Static output): 12V output when some errors occur / No output at normal.

Unit condition

ON

OFF

ON

2. Usage Example Forced OFF control

Operation ON/OFF signal output

• Condition

• Condition

1-2 (Static input): Close/ Operation with Remote is permitted. (Normal condition) Open/ Unit is forcibly OFF and Remote controller operation is prohibited.

4-5 (Static output): 12V output during the unit ON / No output at OFF

• Example of wiring

Relay (Field supply) T10 (YEL)

Relay (Field supply) T10 (YEL)

Indoor unit control PCB

Central control

The contact in the figure is a state where the card is pulled out. POWER

External contact (Card switch box, etc.: field supply)

NOTE: The wire length from indoor unit to the Relay must be within 2.0m

44

• Example of wiring

Indoor unit control PCB

2m

NOTE: The wire length from indoor unit to the Relay must be within 2.0m Pulse signal changeable to static with JP cutting. (Refer to JP001)

45


Controllers

Remote Controller External Dimensions TIMER REMOTE CONTROLLER (CZ-RTC4)

COMMUNICATION ADAPTOR (CZ-CFUNC2)

256

120

280

167

38 8

79 24.75

120

SEPARATE RECEIVER FOR WIRELESS REMOTE CONTROLLER (CZ-RWSC3)

ON/OFF CONTROLLER (CZ-ANC2)

Storage door Push lightly to open or close

R5

USB terminal

(mm)

(mm)

SERI-PARA I/O UNIT FOR EACH INDOOR UNIT (CZ-CAPBC2)

116

20

WIRELESS REMOTE CONTROLLER

ø22.2

22

R 2.5

20

85

Power indicator Illuminates at power-on

120

16

20

240

120

80

38

290 270

INTELLIGENT CONTROLLER (CZ-256ESMC3)

180

DELUXE WIRED REMOTE CONTROLLER (CZ-RTC5A)

6

160 148

(6)

14

69

115

160 148

121

120

6

70

(6)

Unit: mm

REMOTE SENSOR (CZ-CSRC3)

122

ECONAVI SENSOR (CZ-CENSC1) 17

120

70

System Controller

Switch Box 16

51.9

15

90

15

44

83.5

70.6

70.6

120

60 83.5 105 119

13

24.7

120

Detail of the potbellied hole

SERI-PARA I /O UNIT FOR OUTDOOR UNIT (CZ-CAPDC2)

SYSTEM CONTROLLER (CZ-64ESMC3)

46 24.7

70 106 138

2.0 - R2.5

46

mm

mm

46

Magnified view

47


panasonic.co.nz Panasonic New Zealand Limited 18 Sir Woolf Fisher Drive, Highbrook, East Tamaki, Auckland 2013, New Zealand Phone: 09 272 0100, Fax: 09 272 0134


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.