Led Lux Italia - Outdoor LED Lighting

Page 1

PART TWO


P 96-171 OUTDOOR LIGHTING Street Light P 98

Street Light

Street Light

Street Light

Tunnel Light

Tunnel Light

Tunnel Light

Street Light

Tunnel Light P 106

Tunnel Light

Wall Pack Light P 114

Floodlight

Wallpack

Flood Light P 118

Floodlight

Floodlight

Floodlight

Floodlight

Projection Light P 126

Projection light

Projection light

Projection light

Projection light

Courtyard Light P 134

Courtyard Light -PL

Courtyard Light -PL

Courtyard Light -PL

Courtyard Light -PL

Bollard Light

Bollard Light

LED Stripe Light

LED Stripe Light

Bollard Light P 141

Led Stripe Light P 144


In-Gound Light P 148

In-ground Light

In-ground Light

In-ground Light

On-Ground Lights P 154

On-ground light

Linear Wall Washer P 156

Linear Wall Washer

Led Pixel Light P 158

LED Pixel Light

Wind/Solar Hybrid Lights

Wind/Solar Hybrid Street Light System

P 160

Smart Led

Smart LED Lamp Remote Wireless Intelligent Management System

Light Distribution Category

P 166

Ordering Code Instructions

Appendix P 168

Only standard parameters are specified in the catalogue, please contact business personnel for custom sizes.


Outdoor Lighting

96


97


98


SLR Street light

• Built-in chimney effect heat dissipation structure with self-cleaning function. • Patented modular structure to realize power serialization by changing module quantity. • Flexible drive allocation options for different regions. • Angle adjustable, easy replacement. • Tool-free maintenance.

Wattage

Module Q'ty

Initial Luminous Flux

CCT

SLR03301

33W

01

2500 lm

5000±300K

>91%

L491×W346×H102

SLR06301

63W

02

5100 lm

5000±300K

>91%

L553×W346×H102

SLR09501

95W

03

7700 lm

5000±300K

>91%

L615×W346×H102

SLR12301

123W

04

9500 lm

5000±300K

>91%

L677×W346×H102

SLR15001

150W

05

11900 lm

5000±300K

>91%

L739×W346×H102

SLR18601

186W

06

14300 lm

5000±300K

>91%

L801×W346×H102

SLR22001

220W

07

16600 lm

5000±300K

>91%

L863×W346×H102

SLR24501

245W

08

19000 lm

5000±300K

>91%

L925×W346×H102

SLR27701

277W

09

23000 lm

5000±300K

>91%

L987×W346×H102

SLR30801

308W

10

26000 lm

5000±300K

>91%

L1049×W346×H102

Item No.

Ordering Info 1 Wattage 2 Light Distribution 3 Color Temp

6 Control Mode

Lamp Dimension(mm)

Example: SLR Street Light Ordering Code SLR

30

L2 50 SG V27

1

1

2

6

L2

3

L3

40: 3985±275K

5

308: 308W

L4

D1 57: 5665±355 K

50: 5028±283K

CG: Cold Grey

SG: Silver Grey V27: AC 100-277V

A22: AC 220-240 V 0: Without

4

220: 220W 245: 245W 277: 277W

123: 123W 150: 150W 186: 186W

033: 33W 063: 63W 095: 95W

4 Housing Color 5 Input Voltage

Driver Efficiency

1: Timing

2: ZigBee

6: Photocell

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : L2M111

Lens Code : L3L112

Lens Code : D1M111

Lens Code : L4S112

99


100


SLG Street light

• Smooth and clear casing, optional for different colors. • Excellent heat dissipation system ensures long lifespan effectively. • Remote control system applicable for secondary energy saving. • Angle adjustable. High uniformity and intensity.

Item No.

Wattage

Module Q'ty

Initial Luminous Flux

CCT

Driver Efficiency

SLG07801

78W

60

4760 lm

3985±275K

>88%

L959×W378×H163

SLG09401

94W

72

5710 lm

3985±275K

>90%

L959×W378×H163

SLG11001

110W

84

6660 lm

3985±275K

>91%

L959×W378×H163

SLG12501

125W

96

7610 lm

3985±275K

>91%

L959×W378×H163

SLG14101

141W

108

8560 lm

3985±275K

>91%

L959×W378×H163

Ordering Info 1 Wattage 2 Light Distribution 3 Color Temp 4 Input Voltage 5 Control Mode

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L2S101

Lamp Dimension(mm)

Example: SLG Streetlight Ordering Code SLG

78

L2 40

1 078: 78W 094: 94W

2

3

V24

1

4

5

110: 110W 125: 125W

L2

141: 141W

L3

40: 3985±275K

45: 4503±243K

D1 50: 5028±283K

57: 5665±355 K

2: ZigBee

6: Photocell

V24: AC100-240V 0: Without

1: Timing

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L3L101

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D1M203

101


102


SLA Street light

• Flat-plate design. • Excellent heat dissipation design ensures long lifespan effectively. • Patented asymmetrical lighting distribution system provides multiple options for different road lumination requirements. • Remote control system applicable for secondary energy saving. • Easy installation and Maintenance.

Item No.

Wattage

Module Q'ty

Initial Luminous Flux

SLA032

32W

28

2370 lm

3985±275K

>88%

L425×W297×H120

SLA048

48W

42

3550 lm

3985±275K

>88%

L425×W297×H120

SLA064

64W

56

4740 lm

3985±275K

>88%

L425×W297×H120

SLA078

78W

70

5920 lm

3985±275K

>90%

L465×W297×H120

SLA093

93W

84

7100 lm

3985±275K

>91%

L465×W297×H120

SLA108

108W

98

8780 lm

3985±275K

>91%

L550×W297×H120

SLA123

123W

112

9480 lm

3985±275K

>91%

L550×W297×H120

SLA139

139W

126

10660 lm

3985±275K

>91%

L635×W297×H120

SLA154

154W

140

11850 lm

3985±275K

>91%

L635×W297×H120

SLA170

170W

154

13000 lm

3985±275K

>91%

L720×W297×H120

SLA185

185W

168

14200 lm

3985±275K

>91%

L720×W297×H120

SLA200

200W

182

15400 lm

3985±275K

>91%

L828×W297×H120

216W

196

16500 lm

3985±275K

>91%

L828×W297×H120

SLA216

Ordering Info 1 Wattage 2 Light Distribution 3 Color Temp 4 Input Voltage 5 Control Mode

Light Distribution Curve

Luminous Intensity Unit: cd/klm

Lens Code : L2S101

Driver Efficiency

CCT

Lamp Dimension(mm)

Example: SLA Street Light Ordering Code SLA

123 1

2

3

123: 123W 139: 139W 154: 154W

078: 78W 093: 93W 108: 108W

032: 32W 048: 48W 064: 64W

L2 40

L2

V24

1

4

5

170: 170W 185: 185W 200: 200W

L4

40: 3985±275K A22: AC 220-240 V 0: Without

45: 4503±243K

D1 50: 5028±283K

V24: AC 100-240 V 1: Timing

216: 216W

57: 5665±355 K V27: AC 100-277 V 2: ZigBee

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit: cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D1M201

Lens Code : L4S112

103


104


SLB Street light

• Square and nice design. • Aluminum alloy heat dissipation design ensures long lifespan effectively. • Patented asymmetrical lighting distribution system provides multiple options for various road lumination requirements. • Remote control system applicable for secondary energy saving. • Easy installation with angle adjustable tilt.

Item No.

Wattage Module Q'ty 93W

84

7100 lm

3985±275K

>91%

L467×W299×H197

108W

98

8290 lm

3985±275K

>91%

L467×W299×H197

SLB123

123W

112

9470 lm

3985±275K

>91%

L467×W299×H197

SLB139

139W

126

10600 lm

3985±275K

>91%

L552×W299×H277

SLB154

154W

140

11800 lm

3985±275K

>91%

L552×W299×H277

SLB170

170W

154

13790 lm

3985±275K

>91%

L637×W299×H277

SLB185

185W

168

14210 lm

3985±275K

>91%

L637×W299×H277

SLB200

200W

182

15400 lm

3985±275K

>91%

L745×W299×H277

SLB216

216W

196

16580 lm

3985±275K

>91%

L745×W299×H277

Example: SLB Street Light Ordering Code 093: 93W 108: 108W 123: 123W

139

L2 40 2

40: 3985±275K

A22

3

4

L4 45: 4503±243K

0 5 185: 185W 200: 200W 216: 216W

139: 139W 154: 154W 170: 170W

L2

3 Color Temp

D1 50: 5028±283K

57: 5665±355 K

4 Input Voltage

A22: AC 220-240 V

V24: AC 100-240 V

V27: AC 100-277 V

5 Control Mode

0: Without

1: Timing

2: ZigBee

Light Distribution Curve

Power Consumption > 112W

SLB

1

2 Light Distribution

Power Consumption ≤ 112W

Lamp Dimension(mm)

SLB108

1 Wattage

Power Consumption > 112W

Driver Efficiency

CCT

SLB093

Ordering Info

Power Consumption ≤ 112W

Initial Luminous Flux

Luminous Intensity Unit: cd/klm

Lens Code : L2S101

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit: cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D1M201

Lens Code : L4S112

105


106


TL Tunnel Light

• Aluminum alloy housing and electrostatic sprayed surface reaches good resistance to corrosion, complying with RoHS standard. • Built-in chimney effect thermal management system could solute the decrease of heat dissipation ability caused by dirt retention. • Modular structure could be applied for power variation by module increase and decrease. • Glareless lighting with Patented light distribution technology, safe for driving. • Fast plug-in-out connector ensures a much easier maintenance.

Item No.

Wattage

Module Q'ty

Initial Luminous Flux

Driver Efficiency

CCT

Lamp Dimension(mm)

TL093

93W

03

7100 lm

5028±283K

>91%

L302×W330×H256

TL123

123W

04

9500 lm

5028±283K

>91%

L364×W330×H256

TL154

154W

05

11900 lm

5028±283K

>91%

L426×W330×H256

TL185

185W

06

14200 lm

5028±283K

>91%

L488×W330×H256

TL216

216W

07

16000 lm

5028±283K

>91%

L550×W330×H256

TL246

246W

08

19000 lm

5028±283K

>91%

L612×W330×H256

Ordering Info 1 Wattage 2 Light Distribution 3 Color Temp

Example: TL Tunnel Light Ordering Code TL

L2 50 MB V27 2 0

1

2

3

4

185: 185W 216: 216W 246: 246W

093: 93W 123: 123W 154: 154W L2

D1

L4

40: 3985±275K

4 Housing Color

Light Distribution Curve

216

45: 4503±243K

MB: Matt Black

Light Distribution Curve

50: 5028±283K SG: Silver Grey

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : L2M111

Lens Code : L2S111

Lens Code : D1M111

Lens Code : L4S112

107


108


TLC Tunnel Light

• With nice appearance and good durability. • Patented heat dissipation system guarantees stable performance and long lifespan. • Easy operation applied with spring clamp installation equipment. • Adjustable installation bracket suits different demands for all driveways.

Wattage

Module Q'ty

Initial Luminous Flux

CCT

Driver Efficiency

TLC064

64W

56

4420 lm

5028±283K

>88%

L432×W320×H288

TLC078

78W

70

5570 lm

5028±283K

>90%

L502×W320×H288

TLC093

93W

84

6660 lm

5028±283K

>91%

L572×W320×H288

TLC108

108W

98

7750 lm

5028±283K

>91%

L642×W320×H288

TLC123

123W

112

8840 lm

5028±283K

>91%

L712×W320×H288

TLC139

139W

126

9990 lm

5028±283K

>91%

L782×W320×H288

TLC154

154W

140

11080 lm

5028±283K

>91%

L852×W320×H288

TLC169

169W

154

12240 lm

5028±283K

>91%

L922×W320×H288

TLC185

185W

168

13320 lm

5028±283K

>91%

L992×W320×H288

TLC200

200W

182

14410 lm

5028±283K

>91%

L1062×W320×H288

TLC216

216W

196

15500 lm

5028±283K

>91%

L1132×W320×H288

Item No.

Ordering Info 1 Wattage Power Consumption < 154W

Power Consumption ≥ 154W

2 Light Distribution 3 Color Temp

Example: TLC Tunnel Light Ordering Code TLC 216 1 064: 64W 078: 78W 093: 93W

108: 108W 123: 123W 139: 139W L2 45: 4503±243K

Power Consumption ≥ 154W

2

154: 154W 169: 169W 185: 185W

50 SG V27 3

4

5

200: 200W 216: 216W

L3 50: 5028±283K

4 Housing Color

MB: Matt Black

SG: Silver Grey

5 Input Voltage

V24: AC 100-240 V

V27: AC 100-277 V

Light Distribution Curve

Power Consumption < 154W

L2

Lamp Dimension(mm)

Luminous Intensity Unit : cd/klm

Lens Code : L2S101

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L3L101

109


110


TLD Tunnel Light

• With nice appearance and good durability. • Patented heat dissipation system guarantees stable performance and long lifespan. • Easy maintenance with independent chambers for light source and driver. • Modular structure for power variation. • Adjustable installation bracket suits different demands for all driveways.

Item No.

Wattage

Module Q'ty

Initial Luminous Flux

CCT

Driver Efficiency

Lamp Dimension(mm)

TLD064

64W

56

4420 lm

5000±300K

>88%

L524×W320×H288

TLD078

78W

70

5570 lm

5000±300K

>90%

L594×W320×H288

TLD093

93W

84

6660 lm

5000±300K

>91%

L664×W320×H288

TLD108

108W

98

7750 lm

5000±300K

>91%

L734×W320×H288

TLD123

123W

112

8840 lm

5000±300K

>91%

L804×W320×H288

TLD139

139W

126

9990 lm

5000±300K

>91%

L874×W320×H288

TLD154

154W

140

11080 lm

5000±300K

>91%

L944×W320×H288

TLD169

169W

154

12240 lm

5000±300K

>91%

L1014×W320×H288

TLD185

185W

168

13320 lm

5000±300K

>91%

L1084×W320×H288

TLD200

200W

182

14410 lm

5000±300K

>91%

L1154×W320×H288

Ordering Info 1 Wattage 2 Light Distribution

Example: TLD Tunnel Light Ordering Code TLD

185 1

064: 64W 078: 78W 093: 93W

108: 108W 123: 123W 139: 139W

L2 50 SG 2

154: 154W 169: 169W 185: 185W

3

4 200: 200W

L3

L2

D1

3 Color Temp

45: 4503±243K

50: 5028±283K

4 Housing Color

MB: Matt Black

SG: Silver Grey

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L2S101

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L3L101

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D1M101

111


112


TLB Tunnel Light

• With nice appearance and good durability. • Excellent emission effect with patented heat dissipation system. • Automatic switch and dimming meet special requirements for tunnel lighting. • Adjustable installation bracket suits different demands for all driveways.

Wattage

Module Q'ty

Initial Luminous Flux

TLB032

32W

28

1900 lm

5000±300K

>88%

L342×W299×H210

TLB048

48W

42

2850 lm

5000±300K

>88%

L382×W299×H210

TLB064

64W

56

3800 lm

5000±300K

>88%

L382×W299×H210

TLB078

78W

70

4760 lm

5000±300K

>90%

L382×W299×H210

TLB093

93W

84

5710 lm

5000±300K

>91%

L382×W299×H210

Item No.

Driver Efficiency

CCT

Lamp Dimension(mm)

TLB108

108W

98

6660 lm

5000±300K

>91%

L467×W299×H210

TLB123

123W

112

7610 lm

5000±300K

>91%

L467×W299×H210

TLB139

139W

126

8560 lm

5000±300K

>91%

L552×W299×H210

TLB154

154W

140

9520 lm

5000±300K

>91%

L552×W299×H210

TLB169

169W

154

10400 lm

5000±300K

>91%

L637×W299×H210

TLB185

185W

168

11400 lm

5000±300K

>91%

L637×W299×H210

TLB200

200W

182

12300 lm

5000±300K

>91%

L745×W299×H210

13300 lm

5000±300K

>91%

L745×W299×H210

TLB216

216W

Ordering Info 1 Wattage

196

Example: TLB Tunnel Light Ordering Code TLB

1 078: 78W 093: 93W 108: 108W

032: 32W 048: 48W 064: 64W

2 Light Distribution 3 Color Temp

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L2S101

169 D1 50 2

3

123: 123W 139: 139W 154: 154W

169: 169W 185: 185W 200: 200W

L2 30: 3045±175K

216: 216W

D1 45: 4503±243K

50: 5028±283K

57: 5665±355 K

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D1M201

Lens Code : D1S201

113


114


WPL Wall Pack Light

• Uniform luminance, glare-free, applicable for parking lot lighting. • Aluminum alloy, high corrosion resistance and weather- resistance. • Built-in chimney effect thermal management system with self-cleaning function and reliable performance. • Patented removable-modules design for power variation. • Flexible drive allocation options for different regions.

Wattage

Module Q'ty

Initial Luminous Flux

Driver Efficiency

CCT

96W

03

7100 lm

>91%

5028±283K

L446×W302×H150

WPL128

128W

04

9500 lm

>91%

5028±283K

L446×W364×H150

WPL160

160W

05

11900 lm

>91%

5028±283K

L446×W426×H150

WPL192

192W

06

14200 lm

>91%

5028±283K

L446×W488×H150

WPL224

224W

07

16000 lm

>91%

5028±283K

L446×W550×H150

WPL256

256W

08

19000 lm

>91%

5028±283K

L446×W612×H150

Item No. WPL096

Ordering Info 1 Wattage

Lamp Dimension(mm)

Example: WPL Wall Pack Light Ordering Code WPL

224 1

096: 96W 128: 128W

2 Light Distribution

D1 50 DG V27 1 0 2

3 Color Temp 4 Housing Color

MB: Matt Black

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : L2M111

4

160: 160W 192: 192W

224: 224W 256: 256W

L2 40: 3985±275K

3

D1

45: 4503±243K

50: 5028±283K

DG: Dark Grey

57: 5665±355 K WH: White

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D1S112

115


116


WPL Wall Pack Light

• Applications: Commercial, residential areas, factories, parking lots. • Modular LED structure of LED light source, maximum up to 90W. • Optional accessories of photocell and infrared sensor. • 10%, 30%, 60%, 100% dimming control for saving energy. • Different light distributions available. • Working environment temperature: -40° C to 55° C • Color: Bronze/ Metallic dark grey.

Item No.

Wattage

Module Q'ty

Initial Luminous Flux

CCT

Driver Efficiency

WPL03001

30W

01

2300 lm

3985±275K

>91%

L264xW352xH192mm L326xW352xH192mm L388xW352xH192mm

WPL06001

60W

02

4800 lm

3985±275K

>91%

WPL09001

90W

03

7500 lm

3985±275K

>91%

Ordering Info 1 Wattage

Example: WPL Wall Pack Light Ordering Code WPL

H

090 1

L2 50 BW SG V24 2

2 0

3

030: 30W 060: 60W 090: 90W

2 Light Distribution 3 Color Temp

Lamp Dimension(mm)

L2 30: 3045±175K

L3 45: 4503±243K

D1

50: 5028±283K

57: 5665±355 K

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

W

L

Lens Code : L2M111

Lens Code : L3L112

Lens Code : D1M111

117


118


FL Floodlight

• Aluminum alloy, high corrosion resistance and weather-resistance • Built-in chimney effect thermal management system with self-cleaning function and reliable performance. • Patented removable-modules design for power variation. • Flexible drive allocation options for different regions.

Item No.

Wattage

Module Q'ty

Initial Luminous Flux

Driver Efficiency

CCT

Lamp Dimension(mm)

FL093

93W

03

7100 lm

>91%

5028±283K

L302×W330×H129

FL123

123W

04

9500 lm

>91%

5028±283K

L364×W330×H129

FL154

154W

05

11900 lm

>91%

5028±283K

L426×W330×H129

FL185

185W

06

14200 lm

>91%

5028±283K

L488×W330×H129

FL216

216W

07

16000 lm

>91%

5028±283K

L550×W330×H129

FL246

246W

08

19000 lm

>91%

5028±283K

L612×W330×H129

Ordering Info 1 Wattage 2 Light Distribution 3 Color Temp 4 Housing Color

Example: FL Floodlight Ordering Code FL

246

L2 50 DG V27 0 0

1

2

3

4

185: 185W 216: 216W 246: 246W

093: 93W 123: 123W 154: 154W L2

L4

40: 3985±275K

45: 4503±243K

MB: Matt Black

D1 50: 5028±283K DG: Dark Grey

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : L2M111

Lens Code : D1M111

Lens Code : L4S112

119


120


FLN Floodlight

• Rectangular shaped, simple appearance with classic black and white color match providing a comfortable vision • Patented heat dissipation system guarantees steady performance and long lifespan. • Narrow light angle, uniform light spots, wide illumination area. • Projection angle adjustable according to different requirements, convenient and firm installation.

Wattage

Module Q'ty

Initial Luminous Flux

Driver Efficiency

CCT

Lamp Dimension(mm)

FLN064

64W

56

4740 lm

>88%

3700-5600K

L308×W320×H321

FLN078

78W

70

5920 lm

>90%

3700-5600K

L356×W320×H321

FLN093

93W

84

7100 lm

>91%

3700-5600K

L405×W320×H321

FLN108

108W

98

8780 lm

>91%

3700-5600K

L453×W320×H321

FLN123

123W

112

9470 lm

>91%

3700-5600K

L502×W320×H321

FLN139

139W

126

10700 lm

>91%

5028±283K

L550×W320×H321

FLN154

154W

140

11800 lm

>91%

3700-5600K

L599×W320×H321

FLN169

169W

154

13000 lm

>91%

3700-5600K

L647×W320×H321

FLN185

185W

168

14200 lm

>91%

3700-5600K

L696×W320×H321

Item No.

Ordering Info

Example: FLN Floodlight Ordering Code FLN

1 108: 108W 123: 123W 139: 139W

064: 64W 078: 78W 093: 93W

1 Wattage

154

D5 50 MB V24 2 0 2

3 154: 154W 169: 169W 185: 185W

2 Light Distribution

D5

D7

3 Installation Mode

1: Pole

2: Wall

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D5N103

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D7M101

121


122


FLT Floodlight

• Modular structure, rectangular housing and streamline shape. • U type bracket to adjust angle easily. • Applicable for large space lighting. • Flat plate appearance, rectangular housing and streamline shape. • Flat window design to realize anti-glare. • Split design, independent driver and controller with stable performance.

Driver Efficiency

CCT

Lamp Dimension(mm)

2500 lm

>88%

5028±283K

L365×W297×H237

42

3800 lm

>88%

5028±283K

L365×W297×H237

56

4740 lm

>88%

5028±283K

L365×W297×H237

90W

70

5920 lm

>90%

5028±283K

L365×W297×H237

FLT107

107W

84

7100 lm

>91%

5028±283K

L405×W297×H237

FLT125

125W

98

8780 lm

>91%

5028±283K

L485×W297×H237

FLT143

143W

112

9470 lm

>91%

5028±283K

L525×W297×H237

FLT161

161W

126

10700 lm

>91%

5028±283K

L565×W297×H237

FLT179

179W

140

11800 lm

>91%

5028±283K

L605×W297×H237

FLT197

197W

154

13000 lm

>91%

5028±283K

L485×W297×H237

FLT215

215W

168

14200 lm

>91%

5028±283K

L525×W297×H237

FLT233

233W

182

16300 lm

>91%

5028±283K

L565×W297×H237

FLT250

250W

196

17600 lm

>91%

5028±283K

L605×W297×H237

Wattage

Module Q'ty

FLT037

37W

28

FLT055

55W

FLT073

73W

FLT090

Item No.

Ordering Info

Example: FLT Floodlight Ordering Code FLT

233 1

037: 37W 055: 55W 073: 73W

1 Wattage

Initial Luminous Flux

090: 90W 107: 107W 125: 125W

D1 50 MB V24 2 0 2

143: 143W 161: 161W 179: 179W

3 197: 197W 215: 215W 233: 233W

2 Light Distribution

D1

L2

3 Installation Mode

1: Pole

2: Wall

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D1S201

250: 250W

Lens Code : L2S101

123


124


FLU Floodlight

• Flat plate appearance, rectangular housing and streamline shape. • Adjustable mounting bracket, firm and reliable installation. • Applicable for large space multi-dimensional lighting. • Flat plate appearance, rectangular housing and streamline shape. • Flat window design to realize anti-glare. • Split design, independent driver and controller with stable performance.

Wattage

Module Q'ty

Initial Luminous Flux

Driver Efficiency

CCT

Lamp Dimension(mm)

FLU037

37W

28

2500 lm

>88%

5028±283K

L342×W299×H177

FLU055

55W

42

3800 lm

>88%

5028±283K

L382×W299×H177

FLU073

73W

56

4740 lm

>88%

5028±283K

L382×W299×H177

FLU090

90W

70

5920 lm

>90%

5028±283K

L382×W299×H177

FLU107

107W

84

7100 lm

>91%

5028±283K

L382×W299×H177

FLU125

125W

98

8780 lm

>91%

5028±283K

L467×W299×H177

FLU143

143W

112

9470 lm

>91%

5028±283K

L467×W299×H177

FLU161

161W

126

10700 lm

>91%

5028±283K

L552×W299×H177

FLU179

179W

140

11800 lm

>91%

5028±283K

L552×W299×H177

FLU197

197W

154

13000 lm

>91%

5028±283K

L673×W299×H177

FLU215

215W

168

14200 lm

>91%

5028±283K

L673×W299×H177

FLU233

233W

182

16300 lm

>91%

5028±283K

L745×W299×H177

FLU250

250W

196

17600 lm

>91%

5028±283K

L745×W299×H177

Item No.

Example: FLU Floodlight

Ordering Info 1 Wattage

Ordering Code FLU

179 1

090: 90W 107: 107W 125: 125W

037: 37W 055: 55W 073: 73W

2 Light Distribution 3 Installation Mode

D5 50 MB V24 2 0 2

143: 143W 161: 161W 179: 179W

D1

3 197: 197W 215: 215W 233: 233W

250: 250W

D5 1: Pole

2: Wall

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D1S201

Lens Code : D1M201

Lens Code : D5M101

125


126


PJL Projection Light

• Matt black appearance, lens shade optional. • Aluminum alloy adopted, good corrosion and shock resistance with anodized spayed coating. • Accurate light distribution design, highly focused light beam. • Projection angle adjustable according to the height of the object, single color and full color solutions for option. • High IP rate to adapt in harsh environment.

Item No.

Wattage

LED Q'ty

CCT

Input Voltage

Lamp Dimension(mm)

PJL4201

42W

36 x HP LED

Single/FC

AC 100-240V

L330×W289×H265

PJL5201

52W

48 x HP LED

Single/FC

AC 100-240V

L330×W289×H265

PJL6801

68W

60 x HP LED

Single/FC

AC 100-240V

L330×W289×H265

Example: PJL Projection Light

Ordering Info

Ordering Code PJL

68

D5

40 MB V24

1

2

1 Wattage

42: 42W

52: 52W

2 Color Temp/ Light Color

30: 3045±175K

40: 3985±275K

RR: Red

3 Housing Color

GG: Green

Light Distribution Curve

Luminous Intensity Unit : cd/klm

4

68: 68W 50: 5028±283K

YY: Yellow

MB: Matt Black

4 Control Mode

Lens Code : D5001

BB: Blue

2 0

3

AM: Amber

FC: Full Color

SG: Silver Grey 3: DMX512

0: Without

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D5003

127


128


PJL Projection Light

• Small size, easy to hide, beam angle adjustable. • The angle of the base adjustable. • Die-casting aluminum material, good sealing performance, uniform heat dissipation.

Item No.

Wattage

LED Q'ty

CCT

Input Voltage

PJL2001

20W

18 x K2

FC

DC24V

Ordering Info 1 Color Temp/ Light Color 2 Housing Color 3 Control Mode

Lamp Dimension(mm) L103×W144×H210

Example: PJL Projection Light Ordering Code PJL

020

D5 40 MB V24 1

30: 3045±175K RR: Red

GG: Green

2

40: 3985±275K BB: Blue

2 0 3

50: 5028±283K

YY: Yellow

AM: Amber

FC: Full Color

MB: Matt Black 3: DMX512

0: Without

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D5020

Lens Code : D5014

Lens Code : D5015

Lens Code : D5015

129


130


PJL Projection Light

• Unique appearance, angle adjustable. • Small size, concealed installation. • Beam angel adjustable.

Item No.

Wattage

LED Q'ty

CCT

Input Voltage

Lamp Dimension(mm)

PJL0301

3W

3 x K2

FC

DC24V

Φ70×W92×H110

Ordering Info 1 Wattage 2 Color Temp/ Light Color 3 Housing Color 4 Control Mode

Example: PJL Projection Light Ordering Code PJL

03

D5

1

40 MB V24 2

3

0 0 4

03: 3W 30: 3045±175K RR: Red

GG: Green

40: 3985±275K BB: Blue

50: 5028±283K

YY: Yellow

AM: Amber

FC: Full Color

MB: Matt Black 0: Without

1: DMX512

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D5020

Lens Code : D5014

Lens Code : D5015

Lens Code : D5022

131


132


PJL Projection Light

• Unique appearance, angle adjustable. • Small size, concealed installation. • Beam angel adjustable.

Item No.

Wattage

LED Q'ty

CCT

Input Voltage

PJL1001

10W

9 x K2

RR/YY/AM 2700K-3000K 4000-5000K

DC24V

Ordering Info 1 Color Temp/ Light Color 2 Housing Color 3 Control Mode

Lamp Dimension(mm) L114×W116×H196mm

Example: PJL Projection Light Ordering Code PJL 1001

D5

40 MB V24 1

30: 3045±175K RR: Red

GG: Green

2

40: 3985±275K BB: Blue

3

50: 5028±283K

YY: Yellow

MB: Matt Black

0 0

AM: Amber

FC: Full Color

SG: Silver Grey 3: DMX512

0: Without

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D5020

Lens Code : D5014

Lens Code : D5015

Lens Code : D5022

133


134


CL Courtyard Light

• Oliver-shape design increasing vivid atmospheres in parks, also nice decoration for landscape during the day. • High Uniformity. Create peaceful atmospheres in the park. • Solar-powered driver as options, secondary energy saving effects. • Long lifetime design, environment-friendly.

CCT

Driver Efficiency

Lamp Dimension(mm)

1050 lm

2600-5600K

>88%

Φ452×H550

2100 lm

2600-5600K

>88%

Φ452×H550

36

3150 lm

2600-5600K

>88%

Φ452×H550

56W

48

4200 lm

2600-5600K

>88%

Φ452×H550

60W

60

5300 lm

2600-5600K

>88%

Φ452×H550

Initial Luminous Flux

Item No.

Wattage

CL1401

14W

12

CL2801

28W

24

CL4201

42W

CL5601 CL6001

Example: CL Courtyard Light

Ordering Info

Ordering Code CL

36 01 D1 45 1

1 Wattage

12: 12W 24: 24W

36: 36W 48: 48W

2 Color Temp

45: 4503±243K

50: 5028±283K

3 Housing Color

BK: Black

Light Distribution Curve

BK A22 1 0

2

MB: Matt Black

3 60: 60W

WH: White

SG: Silver Grey

Light Distribution Curve

758

258

568

194

379

129

189

65

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D1M201

Lens Code : D1M201

Parallel Arrangement

Round Arrangement

135


136


CL Courtyard Light

• Dress-hat shape design full of European classical style. • Symmetrical light distribution with high uniformity. • Solar-powered driver to achieve energy saving is optional.

Driver Efficiency

Lamp Dimension(mm)

Wattage

LED Q'ty

Initial Luminous Flux

CL1202

12W

12

1050 lm

2600-5600K

>88%

Φ500×H300

CL2402

24W

24

2100 lm

2600-5600K

>88%

Φ500×H300

CL3602

36W

36

3150 lm

2600-5600K

>88%

Φ500×H300

CL4802

48W

48

4190 lm

2600-5600K

>88%

Φ500×H300

CL6002

60W

60

5300 lm

2600-5600K

>88%

Φ500×H300

Item No.

CCT

Example: CL Courtyard Light

Ordering Info

Ordering Code CL

36 02 D1 1

12: 12W 24: 24W

1 Wattage 2 Color Temp

40: 3985±275K

3 Housing Color

BK: Black

Light Distribution Curve

2

36: 36W 48: 48W 45: 4503±243K MB: Matt Black

WH: White

50: 5028±283K SG: Silver Grey

Light Distribution Curve 258

568

194

379

129

189

65

Lens Code : D1M201 Parallel Arrangement

3 60: 60W

758

Luminous Intensity Unit : cd/klm

50 BK A22 1 0

Luminous Intensity Unit : cd/klm

Lens Code : D1M201 Round Arrangement

137


138


CL Courtyard Light

• Elegant appearance, European and Arabian styles. • Optional color for pole and lampshade, solar powered available.

Item No.

Wattage

LED Q'ty

Initial Luminous Flux

CCT

Driver Efficiency

Lamp Dimension(mm)

CL1203

12W

12

1210 lm

2700-5500K

> 90%

Φ358×H585

CL2403

24W

24

2420 lm

2700-5500K

> 90%

Φ358×H585

2700-5500K

> 90%

Φ358×H585

2700-5500K

> 90%

Φ358×H585

CL3603

36W

36

3630 lm

CL4803

48W

48

4840 lm

Example: CL Courtyard Light

Ordering Info

Ordering Code CL

12 03 S1 30 BK A22 1 0

12: 12W 24: 24W

36: 36W 48: 48W

2 Color Temp

27: 2700±220K 30: 3000±220K

35: 3500±220K 40: 4000±220K

3 Housing Color

BK: Black

1

1 Wattage

Light Distribution Curve

MB: Matt Black

2

WH: White

258

568

194

379

129

189

65

Lens Code : D1M201 Parallel Arrangement

45: 4500±220K 50: 5000±220K SG: Silver Grey

Light Distribution Curve

758

Luminous Intensity Unit : cd/klm

3

Luminous Intensity Unit : cd/klm

Lens Code : D1M201 Round Arrangement

139


CL Courtyard Light

• Dress-hat shape base on the traditional Courtyard Light design. • Modular LED structure of LED light source, maximum up to 105W. • Symmetrical light distribution with high uniformity. • 2W per LED with high lumens output efficiency. • Working environment temperature: -40° C to 55° C.

Item No.

Wattage

LED Qty

115W

49

CL115

>8500lm

Ordering Code CL

Lamp Dimension(mm)

5000±300K

> 90%

L570xW570xH435

115

D1M 50 SG V27

1

1 Wattage

115: 115W

2 Lens Type

D1M: D1M The lens is Round Array

3 CCT 4 Fixture Finishing 5 Input Voltage

30: 2700K-3300K

40: 3700K-4300K

50: 4700K-5300K

60: 5700K-6300K

2

3

SG: Silver Gray

BK: Black

WT: White

BN: Bronze

V27: AC 120V-277V

Light Distribution Curve

Light Distribution Curve

758

258

568

194

379

129

189

65

Luminous Intensity Unit : cd/klm

Lens Code : D1M201 Parallel Arrangement

140

Driver Efficiency

Example: CL Courtyard Light

Ordering Info

H376

CCT

Initial Luminous Flux

Luminous Intensity Unit : cd/klm

Lens Code : D1M201 Round Arrangement

4

5


141


BL Bollard Light

• Patented mushroom design increasing interest value of the nightview. • Beautification and illumination functions are available with soft light abd asymmetric light distribution. • Safety treatment for sharp edges to prevent children injury.

Item No.

Wattage

LED Q'ty

BL1201

12W

10xLUMI LED

Lamp Dimension(mm)

Input Voltage

CCT 2700-3000K

AC 100-240V

3800-4100K

Φ300×H419

5000-5650K

Ordering Info 1 Light Source 2 Housing Color

Example: BL Bollard Light Ordering Code BL

1201 A4 50 CG V24 0 0 1

50: 5028±283K

40: 3985±275K MB: Matt Black

CG: Cold Grey

Light Distribution Curve 303 227 152 75

Luminous Intensity Unit : cd/klm

Lens Code : L4S101

142

2

WH: White


BL Bollard Light

• Super-thin appearance, upright and foursquare structure combined with streamline design. • Module design, easy maintenance. Light can be emitted from single or double sides. • Unique light distribution, slope downward light doesn’t affect the night view. • Easy installation .long lifespan. Environmentally friendly.

Power Consumption

LED Q'ty

CCT

Input Voltage

Lamp Dimension(mm)

BL0602

6W

6xLUMI LED

3800-4700K

AC 110-240V

L113×W107×H603

BL1202

12W

6xLUMI LED

5000-5650K

AC 110-240V

L113×W107×H603

Item NO.

Ordering Info

Example: BL1D Bollard Light Ordering Code BL

1202 R4 50 CG V24 0 0 1

1 Light Source

06: 6W

2

3 12: 12W

2 Color Temp

40: 3985±275K

50: 5028±283K

3 Housing Color

MB: Matt Black

CG: Cold Grey

Light Distribution Curve 854 650 427 224

Luminous Intensity Unit : cd/klm

143


144


LSL LED Strip Light

• Slender shape, lighting large vertical view of the building. • Two options fot light distribution, patented wall washing and narrow beam angel. • Anodic oxidation process. • Higher light transmittance with toughened glass. • The functions of the fixtures change with different lens.

Item No.

Power Consumption

LED Q'ty

Color

Input Voltage

Lamp Dimension(mm)

LSL1501

15W

12 x K2/CREE

Single / RGB

DC24V

L500×W77×H135

LSL2201

22W

18 x K2/CREE

Single / RGB

DC24V

L1000×W77×H135

LSL3001

30W

24 x K2/CREE

Single / RGB

DC24V

L1000×W77×H135

LSL4201

42W

36 x K2/CREE

Single / RGB

DC24V

L1000×W77×H135

LSL5501

55W

48 x K2/CREE

Single / RGB

DC24V

L1000×W77×H135

Ordering Info 1 Wattage 2 Color Temp/ Light Color

Example: LSL LED Stripe Light Ordering Code LSL

12 01 D5 40 AP V24 1

3

0 0 4

36: 42W 48: 55W

12: 15W 18: 22W 24: 30W 30: 3045±175K RR: Red

2

GG: Green

3 Housing Color

AP: Aluminum

4 Control Mode

0: Without

Light Distribution Curve

40: 3985±275K BB: Blue

50: 5028±283K

YY: Yellow

AM: Amber

FC: Full Color

3: DMX512

Light Distribution Curve

Types below are to be found in appendix D5014 D5015 D5022

Luminous Intensity Unit : cd/klm

Lens Code : D5020

Luminous Intensity Unit : cd/klm

Lens Code : D7L101

145


146


LSL LED Strip Light

• Higher light transmission, uniform light mixing effect. Top-ranking brand highperformance LED chip. • Reasonable and high- efficiency heat dissipation technology to ensure lamp longer lifespan. • Aluminium alloy light body, tempered glass cover.

Item No.

Power Consumption

LED Q'ty

Color

Input Voltage

Dimension(mm)

LSL1002

10W

9

Single / RGB

DC24V

L500×W56×H100

LSL1402

14W

12

Single / RGB

DC24V

L500×W56×H100

LSL1802

18W

15

Single / RGB

DC24V

L500×W56×H100

LSL2002

20W

18

Single / RGB

DC24V

L1000×W56×H100

LSL2702

27W

24

Single / RGB

DC24V

L1000×W56×H100

LSL3402

34W

30

Single / RGB

DC24V

L1000×W56×H100

LSL4002

40W

36

Single / RGB

DC24V

L1000×W56×H100

Ordering Info 1 Wattage 2 Color Temp/ Light Color

Example: LSL LED Stripe Light Ordering Code LSL

1

30: 3045±175K RR: Red

GG: Green

2

3

2 0 4

40: 40W

20: 20W 27: 27W 34: 34W

10: 10W 14: 14W 18: 18W

3 Housing Color 4 Control Mode

40 02 D5 40 AP V24

40: 3985±275K BB: Blue

50: 5028±283K

YY: Yellow

AM: Amber

FC: Full Color

AP: Aluminum 0: Without

Light Distribution Curve

3: DMX512

Light Distribution Curve

Types below are to be found in appendix D5014 D5015 D5022

Luminous Intensity Unit : cd/klm

Lens Code : D5001

Luminous Intensity Unit : cd/klm

Lens Code : D7L101

147


148


IGL In-ground Light

• Long lifespan, low power consumption, low surface temperature • Aluminum alloy light shell, Corrosion resistance and acid-base resistance. • Unique light shell structure maintains stable position underground without extrusion for a prolonged period of time. • Water-proof triple-sealed bearing to prevent water or fog penetration in the lights. • Lighting in four directions to prevent glaring, can bear over 2.000 kg pressure.

Item NO.

Power Consumption

IGL1101

Ordering Info

11W

LED Q'ty

Color Temp

Input Voltage

Lamp Dimension(mm)

5000-5650K

AC 110-240

Φ210×H220

4 x CREE/LUMI LED

Example: IGL In-ground Light Ordering Code IGL

1101 D5 45 SG V24

6 0

1

1 Color Temp

45: 4503±243K

50: 5028±283K

Light Distribution Curve 205 158 95 47

Luminous Intensity Unit : cd/klm

Lens Code : D5N103 D5N104

149


150


IGL In-ground Light

• Long lifespan, low power consumption, low surface temperature. • Alluminum alloy light shell, Corrosion resistance and acid-base resistance. • Unique light shell structure maintains stable position underground without extrusion for a prolonged period of time. • Water-proof triple-sealed bearing to prevent water or fog penetration in the lights. • Can bear over 1.500 kg pressure.

Item NO.

Power Consumption

IGL3001

30W

Ordering Info 1 Color Temp

LED Q'ty

Color Temp

Input Voltage

Lamp Dimension(mm)

18xLUMI LED

5000-5650K

AC 110-240

Φ210×H172

Example: IGL In-ground Light Ordering Code IGL

3001

S5 45 SG V24

6 0

1 45: 4503±243K

50: 5028±283K

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Lens Code : D5N103 D5N104

151


152


IGL In-ground Light

• Round light emitting area, small beam angle ,longer lighting distance, much more wider applications. • Two beam angle available. • Stainless steel material on the surface , abrasion resistant and anti-corrosion.

Power Consumption

Item NO.

LED Qty

Color Temp

Input Voltage

Lamp Dimension(mm)

IGL0401

4W

3xK2

Single/RGB

DC24V

Φ130×H175

IGL0901

9W

6xK2

Single/RGB

DC24V

Φ130×H175

Ordering Info

Example: IGL In-ground Light Ordering Code IGL

04 01 D5 1

1 Wattage

04: 4W 09: 9W

2 Color Temp

45: 4503±243K

50: 5028±283K

3 Control Mode

0: without

1: DMX512

45 SG V24

6 0

2

RGB

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Light Distribution Curve

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Lens Code : D5020

Lens Code : D5014

Lens Code : D5015

Lens Code : D5022

153


154


OGL On-ground Light

• Long lifespan, low power consumption, low surface temperature. • Aluminum alloy light shell, Corrosion resistance and acid-base resistance. • Water-proof triple-sealed bearing to prevent water or fog penetration In the lights. • Lighting in four directions to prevent glaring.

Item NO.

Power Consumption

LED Q'ty

Color Temp

Input Voltage

Lamp Dimension(mm)

OGL1101

11W

4 x K2 LED

5000-5650K

AC 110-240V

Φ210×H200

Ordering Info 1 Color Temp 2 Housing Color

Example : OGL On-ground Light Ordering Code

OGL

1101

D5

45 SG V24 1

45: 4503±243K MB: Matt Black

0 0

2

50: 5028±283K WH: White

SG: Silver Grey

Light Distribution Curve 205 158 95 47

Luminous Intensity Unit : cd/klm

Lens Code : D5N103

155


156


LWL Linear Wall Washer

• Cream white Lampshade, consistent with architecture style. • Working in parallel or vertical, different color schemes to create different landscapes via control system. • Long lifetime, low power, energy-saving and environmentally friendly. • All in one with high IP class.

Item NO.

Power Consumption

LWL0601

LWL1201

Ordering Info

6W

12W

LED Q‘ty

Color Temp

Input Voltage

Lamp Dimension(mm)

72 x Φ5

RR/YY/GG B B / R G B Warm white Neutral white Cool White

DC 24V

L500×W55xH77

144 xΦ5

RR/YY/GG B B / R G B Warm white Neutral white Cool White

DC 24V

L1000×W55xH77

Example : LWL Linear Wall Washer Ordering Code

LWL 1201 D5 45 SG V24 1

1 Wattage

06: 6W 12: 12W

2 Color Temp

45: 4503±243K

3 Housing Color

MB: Matt Black

2

0 0

3

50: 5028±283K WH: White

SG: Silver Grey

157


158


LPL LED Pixel Light

• The finish small and exquisite, easy for installments, and several color alternatives. • Lighting the vertical view of the building • Several color alternatives, flexible control. • Safe and easy for installment. • The cover is anti-UV materials. A better proof for the lifetime.

Item NO.

Power Consumption

LED Q'ty

Color Temp

Input Voltage

Lamp Dimension(mm)

LPL0401

4W

18 x SMD5050

Single / RGB

DC 24V

L108×W108xH65

LPL0601

6W

30 x SMD5050

Single / RGB

DC 24V

L202×W202xH82

Ordering Info 1 Wattage

2 Color Temp 3 Housing Color

Example :LPL LED Pixel Light Ordering Code

LPL

0601 NO RR DG D24 1

2

2 0

3

04: 4W 06: 6W 45: 4503±243K

50: 5028±283K

RR: Red

BB: Black

GG: Green

FC: Full Color

YY: Yellow

DG: Deep Grey

W

L

H

159


Wind/Solar Hybrid Street Light System • Independent system without external power supply. • Automatic sensor, intelligent control. • Energy saving and durable, easy maintenance.

Wind & Solar Controller

PV Arrays

street light application

Storage Battery Wind Generator

Power Supply System Sketch

160


Wind/Solar Hybrid Street Light System System Drawing Overview :

solar Panel LED Street Light

Lamp Pole

Concrete Base Battery

161


Wind/Solar Hybrid Street Light System - HSL Showcase : Wind-Solar powered LED street light in Shipai Wetland Park, Dongguan, China

162


Wind/Solar Hybrid Street Light System - HSL System Configuration : Consumption

Pole height

Solar panel

Wind generator

Solar battery

Controller

Working hours

Application

HSL03001

30W

6m

80WP

300-400W

120Ah

10A/12V

10h

Country Road

HSL06001

60W

8m

120WP

300-400W

100Ahx2

10A/12V

10h

Sub Street

HSL09001

90W

8m

200WP

300-400W

150Ahx2

10A/12V

10h

Sub Street

HSL12001

120W

10m

250WP

400-600W

200Ahx2

20A/24V

10h

Sub Street

Model

Note : above configuration are only for reference, each project need special design accordingly.

Pilot Project : 1、Light up 12 hours per day, 4 hours full brightness, 4 hours 50% dimming, 4 hours full brightness. 2、Minimum 3 days working during raining or cloudy days. 3、Luminous Flux 7600lm, 90w, 4500-5300K. 4、Customized solution: 1 Streetlight+2 panels+1 wind turbine+1 controller+2 batteries+1 pole (including base and holder). SLR09501 Steet light

DC24V 95W

Solar Panel

L1580 x W808 x H45mm x 2pcs

Wind turbine

400L-24V

Controller

10A/24V

Battery

12V/200Ah x 2pcs

Panel Holder

L1580 x W1616 x H50mm

Pole Height

9m

Base Holder

L250 x W250 x H1150mm midnight--4h 50% dimming

RVV3 x 4mm,L=9m Cable

RVV2 x 4mm,L=9m RVV2 x 2.5mm,L=8.5m

dusk--4h full brightness

dawn--4h full brightness

163


Wind/Solar Hybrid Street Light System Specification: SLR - LED Street Light: Model

LED Brand

Voltage

Consumption

Luminous Flux

Size(mm)

IP

SLR03301

Cree/Philips Lumileds/Osram

DC12/24V

33W

2500-2600lm

L502 X W346 X H102

65

SLR06301

Cree/Philips Lumileds/Osram

DC12/24V

63W

4800-4900lm

L546 X W346 X H102

65

SLR09501

Cree/Philips Lumileds/Osram

DC12/24V

95W

7000-7200lm

L626 X W346 X H102

65

SLR12301

Cree/Philips Lumileds/Osram

DC12/24V

123W

9400-9500lm

L688 X W346 X H102

65

Solar Controller: Model

Rated Output Current

PV Maximum Current

Rated Wind Turbine Power

Rated Wind Turbine Maximum Input Current

Rated battery Voltage

Output Protection Voltage

SC300

10A

10A

300W

40A

12V

16V

SC600

10A

10A

600W

40A

24V

32V

Wind Turbine:

164

Model

Rated Wind Speed

Survival Wind Speed

Rated Output Power

Rated DC Voltage

Diameter

Material

WT300

10m/s

50m/s

300W

12V/24V

1.5m

nylon+glassfiber

WT400

12m/s

50m/s

400W

12V/24V

1.4m

nylon+glassfiber

WT600

11m/s

50m/s

600W

24V

1.9m

nylon+glassfiber

WT1000

12m/s

50m/s

1000W

24V/48V

2.7m

nylon+glassfiber


Wind/Solar Hybrid Street Light System PV Panel: Item

Model

Spec

Panel Size(mm)

Hole Site(mm)

Power

1

70(17)P900×660

I

L900 x W660

L626 x W510

70-80W

2

80(17)P 1010×660

I

L1010 x W660

L626 x W510

75-90W

3

80(17)P 1172×541

I

L1172 x W541

L507 x W592

75-85W

4

80(17)P 1210×545

I

L1172 x W541

L511 x W610

75-85W

5

130(17)P 1010×990

I

L1010 x W990

L946 x W510

110-140W

6

120(17)P1470×680

I

L1470 x W680

L646 x W870

110-140W

7

120(17)P1480×665

I

L1480 x W665

L621 x W780

110-140W

8

170(35)P1580×808

I

L1580 x W808

L764 x W950

160-175W

9

170(35)P1600×810

I

L1600 x W810

L766 x W970

160-175W

10

180(23)P1310×990

I

L1310 x W990

L946 x W680

160-185W

11

180(23)P1335×990

I

L1335 x W990

L946 x W720

160-185W

12

190(26)P1495×990

I

L1495 x W990

L946 x W755

180-200W

13

220(29)P1650×990

I

L1650 x W990

L946 x W1020

200-230W

14

220(29)P1650×1030

I

L1650 x W1030

L986 x W1020

200-230W

15

240(32)P1810×990

I

L1810 x W990

L946 x W1210/610

230-250W

16

270(32)P1970×990

I

L1970 x W990

L946 x W1310/660

250-280W

Battery: Model

Max Charging Current

Capacity(Ah)10HR

Size

Weight

Rated Voltage

B080

0.25C10(A)

80

L329 x W172 x H215

31kg

12V

B100

0.25C10(A)

100

L329 x W172 x H215

33kg

12V

B120

0.25C10(A)

120

L483 x W172 x H242

41.5kg

12V

B150

0.25C10(A)

150

L483 x W172 x H242

44.5kg

12V

B200

0.25C10(A)

200

L522 x W240 x H220

62.5kg

12V

165


Smart LED Light Remote Wireless Intelligent Management System Remote Control system Scheme : Computer sends messages including controlling orders, etc. to field controller through internet and GPRS network, then field controller releases messages to each lamp’s node by Radio Frequency. One field controller could manage all lamps in its field, and many controllers could be connected to one or more computers with GPRS network to realize remote management. Messages could be sent between computer and each single lamp mutually.

Field Controller

GPRS Module

ZigBee Node(Cord)

Luminaire 1

GPRS Module

ZigBee Node(RFD)

Luminaire n

Field Controller

ZigBee Node(Cord)

Luminaire 1

Luminaire n

Ⅰ、System Function 1、Control : (1) Group Control: 0%-100% dimming control for a single road or couple roads in a region. (2) Individual Control: For any lamp in one field. (3) Intelligent Control: Adjusting automatically lamps’ working time and designated brightness according to the coordinate. 2、Detection: Info-collection function for gathering operational parameters such as, current, temperature, etc., which could be analyzed through lamp controller or PC. 3、Expert Diagnoses: Instant information could be fed back to PC in case of any abnormality as communication dysfunction, high current or temperature, etc., then PC software would make alarms and records in file. 4、Secondary Energy Saving: Lamps could automatically adjust power and brightness by previous designated time settings for secondary energy saving.

166


Smart LED Light Remote Wireless Intelligent Management System Ⅱ、Main Technical Data 1、LED lamp wireless controller covers a range with over 2km diameter; 2、Average system response time is 3.13 seconds. 3、One LED lamp wireless controller could control 9998 nodes. 4、Electricity saving rate is over 20% (Field measurement 24.1%).

Ⅲ、System Application

Picture 1

1、Traffic lighting as expressway, city street, tunnel, etc. 2、Stadium lighting as exhibition center, workshop, venue, meeting hall, etc. 3、Plaza lighting.

Ⅴ、Hardware Introduction

Picture 2

1、Terminal module (Picture 1) 2、Terminal module installation sketch (Picture 2) 3、Field controller (Picture 3): all terminals in each field are controlled by field controller. Except for controlling and detection function, the controller can be externally fitted to a brightness collection device to adjust lamp dimming in some field.

Ⅵ、PC Software

Picture 3

Background PC controlling software could be functioned with detection, controlling and management by secondary programming.

167


Appendix : Light Distribution Category L2 L2S101

L2S102

L2S103

L2S111

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

L2S201

L2M111

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

L3L101

L3L111

L3L112

L3L113

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

L2S112

Luminous Intensity Unit : cd/klm

L3 L3L201

Luminous Intensity Unit : cd/klm

L4 A4S101

Luminous Intensity Unit : cd/klm

168

L4S102

Luminous Intensity Unit : cd/klm

L4S111

Luminous Intensity Unit : cd/klm

L4S112

Luminous Intensity Unit : cd/klm

L4L113

Luminous Intensity Unit : cd/klm


Appendix : Light Distribution Category D1 D1S101

D1S111

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

D1S201

D1M101

D1M111

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

D1S112

Luminous Intensity Unit : cd/klm

D1S113

Luminous Intensity Unit : cd/klm

D1M201

D1S114

Luminous Intensity Unit : cd/klm

D1M202

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

D5N103

D5N104

D5N105

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

Luminous Intensity Unit : cd/klm

D1M203

Luminous Intensity Unit : cd/klm

D5 D5N101

Luminous Intensity Unit : cd/klm

D5N102

Luminous Intensity Unit : cd/klm

169


Appendix : Light Distribution Category D5N106

Luminous Intensity Unit : cd/klm

D5N114

Luminous Intensity Unit : cd/klm

D5M105

Luminous Intensity Unit : cd/klm

D5N301

Luminous Intensity Unit : cd/klm

D5N107

Luminous Intensity Unit : cd/klm

D5M101

Luminous Intensity Unit : cd/klm

D5M106

Luminous Intensity Unit : cd/klm

D5N302

Luminous Intensity Unit : cd/klm

D5N111

Luminous Intensity Unit : cd/klm

D5M102

Luminous Intensity Unit : cd/klm

D5M107

Luminous Intensity Unit : cd/klm

D5001

Luminous Intensity Unit : cd/klm

D5N112

Luminous Intensity Unit : cd/klm

D5M103

Luminous Intensity Unit : cd/klm

D5M108

Luminous Intensity Unit : cd/klm

D5N113

Luminous Intensity Unit : cd/klm

D5M104

Luminous Intensity Unit : cd/klm

D5M109

Luminous Intensity Unit : cd/klm

D5003

Luminous Intensity Unit : cd/klm

D7 D7M101

Luminous Intensity Unit : cd/klm

170

D7M102

Luminous Intensity Unit : cd/klm

D7L101

Luminous Intensity Unit : cd/klm

D7L111

Luminous Intensity Unit : cd/klm

D7L112

Luminous Intensity Unit : cd/klm


Appendix : Ordering Code Instructions

SL

78 L2 40 SG V24 1 1

1

1

Lamp Classification

2

3

BL: Bollard Luminaires TL: Tunnel Light

4

5

6

FL: Floodlight

LSL: Stripe Light

OGL: On-ground Light

7

8

CL: Column Luminaires SL: Street Light

IGL: In-ground Light

PX: Pixel Light

LWL: Linear Wall Washer

WL: Wall Pack Light

PL: Prosection Light

HSL: Wind/Solar Hybrid Street Ligt System

2

Wattage

LED Power Consumption

3

Light Distribution Type

L2

4

Color Temperature

30: 3045±175K 40: 3985±275K

5

Housing Color

BK: Black Matt Black

6

Input Voltage

A22: AC 220-240V

7

Installation

1: Pole 2: Wall 3: Pendant 4: Ceiling 5: Recessed 0: Place

8

Control Mode

L3

L4

FC: Full Color

RR: Red

D1

D5 45: 4503±243K

GG: Green

BW: Blue White SG: Silver Grey

D7 50: 5028±283K

BB: Blue

CG: Cold Grey WH: White

YY: Yellow

DG: Dark Grey

1: Timing

3: DMX512

6: Photocell

MB:

GY: Golden Yellow

V24: AC 100-240V

0: Without

57: 5665±355K

AM: Amber

V27: AC 100-277V

2: ZigBee 7: Wire

Instructions 1. Definition of Ordering Code: Ordering code consists of 19 letters and Arabic numbers, for example:

FL

150

L2

40

Lamp Classification

Wattage

Light Distribution Type

Color Temperature

SG Housing Color

V24

1

1

Input Voltage

Installation

Control Mode

Means the product ordered is FL series with power consumption 126W, pole mounted, silver grey housing, L2 light distribution, color temperature ranged 3985±275K, input voltage AC240V and timing controller. 2. Products showed in the ordering info are standard items in our company, and those with underlines are optional. If products with other different specifications or parameters are needed, please feel free to call us.

171


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.