Analyzers

Page 1

BROCHURE ANALYZERS

A FFO R D A B LE D IA G N O S T IC S O LU T IO N S F R O M 1 9 96


BUSINESS PRESENTATION Paramedical Srl is an italian company founded in 1996. Paramedical produces and distributes in vitro diagnostic devices and scientific equipments. It is the exclusive distributor of PKL brand for IVD and PPC brand for scientific instruments (Full and Semi-Automated Systems for Clinical Chemistry, Immunoassay and Urine). The company is ISO 9001:2008, ISO 13485:2003 certified. Paramedical is compliant with the European Directive (98/79/CE). The company offers the possibility to buy clinical chemistry reagents in bulk and/or in OEM according to specific customer needs. What you want we can supply. The production of clinical chemistry can be supplied in dedicated bottles specific for the most analyzers available on the market. Paramedical also has a division for educational products (school, university and so on) and for the production of laboratory furniture as lab benches.

ISO 9001:2008 CERTIF. N. 9120.PAR2

PARAMEDICAL srl Via Irno snc, 84098 Pontecagnano Faiano (SA) - ITALY Vat.: IT03117920656 Tel. +39 089.385027 - Fax +39 089.3854479 sales@paramedical.it

www.paramedical.it 1


CHEMISTRY ANALYZERS

PKL PPC 110 Chemistry Analyzer

110

SPECIFICATIONS: • • • • • • • • • •

Analysis method: Kinetic, end point, non-linear, sample blank, reagent blank, etc Light source: halogen lamp, 6V/10W Wavelength range: 300~800nm Absorbance range: -0.3~3.0Abs Wavelength accuracy:±1nm Spectrum band: ±6nm Flowcell: 10mm quartz cell, 32μL volume Temperature control: Room temperature, 25oC,30oC,37oC, (±0.1oC variable) Sampling volume: 100μL~9999μL tunable Cross contamination:≤1.0%

• Stability: ≤0.005Abs/h • Memory: up to 234 items and 20000 test results • Display: Large LCD display • Printer: Built-in thermal printer • Output: Rs232 connecting to PC • Ambient: Room temperature: 10 oC~32 oC; Humidity: =85% • Power: AC 220x(1±10%)V,50Hz • Dimension: 392 x 375x 205mm (length * width * height) 180

PKL PPC 180 Chemistry Analyzer SPECIFICATIONS: ASSAY TYPE End Point, Kinetic, Fixed Time, Multistandard MEMORY 250 methods. FLUIDIC Peristaltic pump. LIGHT SOURCE Digitally controlled halogen lamp and led at 280nm. WAVELENGHT 8 standard interference filters (340nm-405nm-505nm546nm-578nm-630nm) + led at 280 nm. PHOTOMETRIC RANGE 0,0 – 3,0 O.D (0,0 - 2,0 O.D. at 280nm). FLOW CELL Quartz cell. Light path.: 10 mm.

ASPIRATION VOLUME Minimum aspiration volume: 300 µL. FLOW CELL TEMPERATURE Programmable from 15°C to 45°C. INCUBATOR 8 position, programmable from 15°C to 45°C. INTERFACE Graphic display 240x128 pixel with alphanumeric keyboard. PRINTERT Thermic 24 colums. CONNECTION USB optional. DIMENSIONS L: 28 D:36 H:22 cm. POWER SUPPLY 100-240 Vac 50/60 Hz with internal fuse..

PKL PPC 180/W

The PKL PPC 180/W Photometer is for Wine Analysis

TESTS FOR WINE ANALYSIS

8 standard interference filters (340-420-492-505-520-546-578-620) + led at 280 nm. ACETALDEHYDE ACETIC ACID • α-AMMINIC NITROGEN • AMMONIA • ANTHOCYAN • CALCIUM (IONIC) • CATECHINS • CHLORIDE

COLOUR (420-520-620nm) COPPER (IONIC) • CITRIC ACID • D-GLUCONIC ACID • D-LACTIC ACID • GLYCEROL • GLUCOSE • GLUCOSE+FRUCTOSE

IRON (IONIC) L-LACTIC ACID • L-MALIC ACID • MAGNESIUM • POTASSIUM • PYRUVIC ACID • SO2 FREE • SO2 TOTAL

TARTARIC ACID TOTAL POLYPHENOL (Folin-Ciocalteus) • TOTAL POLYPHENOL INDEX (IPT at 280nm)

2


PKL PPC 300 Automated Chemistry Analyzer Assay methods:

End point, 2 end point, kinetic, fix time, bichromatic

Principle:

Photoelectric colorimetry

Light Source:

Halogen lamp 12V/20W

Photometry range:

0~3Abs

Resolution:

0.0001Abs

Wavelength:

10 wavelengths (340nm~800nm)

Throughput:

300tests/hour

Reagent tray:

60 reagents positions

Sample tray:

45 samples positions (including standard, QC)

Reaction tray:

120 reaction cuvettes

Sample volume:

2~100µl, with 0.1 µl increment

Reagent volume:

R1:10~500µl, R2: 10~500µl, with 0,5 µl increment

Minimum reaction volume:

150 µl

Maximum reaction time:

10 minutes

Water Consumption:

6L/hour under working status

Clean unit:

8-step auto-washing system with detergent and 37° C water

Waste:

Biological waste separated from washing solution

Calibration:

Calibration reset, select best test point by reaction curve, no need

second calibration Line; multi-standards assay

Control rules:

Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for

each item, analyzing and printing QC analysis diagram

Temperature control:

Incubator 37 ± 0.1°C

3


PKL PPC 400 Automated Chemistry Analyzer

Assay methods:

End point, 2 end point, kinetic, fix time, bichromatic

Principle:

Photoelectric colorimetry

Light Source:

Halogen lamp 12V/20W

Photometry range:

0~3Abs

Resolution:

0.0001Abs

Wavelength:

10 wavelengths (340nm~800nm)

Throughput:

400tests/hour

Reagent tray:

60 reagents positions

Sample tray:

75 samples positions (including standard, QC)

Reaction tray:

120 reaction cuvettes

Sample volume:

2~100µl, with 0.1 µl increment

Reagent volume:

R1:10~500µl, R2: 10~500µl, with 0,5 µl increment

Minimum reaction volume:

150 µl

Maximum reaction time:

10 minutes

Water Consumption:

6L/hour under working status

Clean unit:

8-step auto-washing system with detergent and 37° C water

Waste:

Biological waste separated from washing solution

Calibration:

Calibration reset, select best test point by reaction curve, no need

second calibration Line; multi-standards assay

Control rules:

Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for

each item, analyzing and printing QC analysis diagram

Temperature control:

Incubator 37 ± 0.1°C 4


HEMATOLOGY ANALYZERS

PKL PPC 90 Hemoglobin Meter SPECIFICATIONS: • • • • • • • •

Parameter: Principle: Sample: Strip: Speed: Measuring Range: Memory: Quality Control:

Hemoglobin,HCT(Hematocrit) Optical reflectance Capillary or venous whole blood (13~15 ul) H12 Hemoglobin Test Strip • Calibration: ≤ 10 seconds • Automatization: 4.0g/dL~24.0g/dL(g/L optional) 250 test results • Power: HQ-A Hemoglonbin control solution • Dimension:

Factory calibrated according to ICSH Self-checking, auto-judging and displaying malfunction DC 6V(Two CR2032 Batteries) 102mm×50mm×19mm

PKL PPC 550H Hematology Analyzer 3- Part Diff SPECIFICATIONS: • Parameters: • Principles of operation: • Aspiration Volume: • Aperture Diameter: • Throughput: • Data storage: • Alarms: • Display: • Control and calibration: • Power requirement: • Input/Output:

WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT,P-LCR,P-LCC 3-part differentiation of WBC, 21 parameters and 3 histograms WBC/RBC/PLT: Electrical Impedance HGB: Photoelectric colorimetry Whole blood 10•L,Pre-diluted 20•L WBC/RBC/PLT 80•m 30 samples per hour More than 100,000 sample results with histograms Error messages 10.4 inches color LCD, resolution 640 x 480 L -J,X,X-R,X-B four control modes,manual and auto-Calibration AC 100V --- 240V, 50/60Hz, 130VA-180VA Support RS232, USB port, Shortcut keys with standard mouse and keyboard Internal 57mm thermal printer, Parallel Port and USB for external printer

550H r

Auto Hematology Analyze

PKL PPC 610H Hematology Analyzer 3- Part Diff SPECIFICATIONS: • Parameters: • Principles of operation: • Aspiration Volume: • Aperture Diameter: • Throughput: • Data storage: • Alarms: • Dilution Ration: • Display: • Control and calibration: • Dimension: • Power requirement: • Input/Output:

WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-CV, RDW-SD, PLT, MPV, PDW, PCT,P-LCR,P-LCC 3-part differentiation of WBC, 21 parameters and 3 histograms WBC/RBC/PLT: Electrical Impedance HGB: Photoelectric colorimetry Whole blood 10•L,Pre-diluted 20•L WBC 100•m,RBC/PLT 68•m 60 samples per hour More than 100,000 sample results with histograms Error messages Whole blood Capillary blood WBC/HGB 1:232 1:400 RBC/PLT 1:40000 1:45000 10.4 inches color LCD L -J,X,X-R,X-B four control modes, manual and auto-Calibration 330mm x 440mm x 500mm AC 100V --- 240V, 50/60Hz, 180W Support RS232, standard network port and USB. Shortcut keys with standard mouse and keyboard. Internal 57mm thermal printer. Parallel Port and USB for external printer 610H

Auto Hematology Analyzer

5


HEMATOLOGY ANALYZERS

PKL PPC 1040H

1040H Auto Hematology Analyzer

Hematology Analyzer 5-Part Diff SPECIFICATIONS:

• 28 parameters: WBC,LYM%,MON%,NEU%,EOS%,BASO%,LYM#, MON#,NEU#,EOS#,BAS#,RBC,HGB, HCT,MCV, MCH,MCHC,RDW_CV,RDW_SD,PLT,MPV,PDW, PCT,P_LCR,P_LCC, RETIC_ABS,RETIC, IRF 2 Histograms for RBC and PLT 2 Scatter grams: 5-part differential scatter gram Eosinophils and Moutrophils scatter gram 2 3-D stereograms • Principles of operation: WBC/DIFF: Flow Cytometry, Laser light multi-dimensional cell classification RBC/PLT Analysis: Impedance method HGB test: Cyanide-free reagent colorimetry • Reagent: Diluent, Sheath,Detergent • Sampling modes: Whole blood 20μL Pre-diluent 20μL • Aperture Diameter: RBC/PLT 68μm • Throughput: Whole blood up to 60 samples per hour Pre-diluent up to 60 samples per hour • Data storage: Up to 200,000 sample results with grams • Alarms: Error messages • Display: PC display (14inch color TFT) • Dimension: 598.5MM(L)×585.5MM(W)×488.5MM(H) • Power: 220V,50/60Hz 600VA • Weigh: 70kg 1100H

Auto Hematology Analy

zer

PKL PPC 1100H

Hematology Analyzer 5 - Part Diff SPECIFICATIONS: • 27 parameters: WBC,LYM%,MON%,NEU%,EOS%,BAS%, LYM#,MON#,NEU#,EOS#,BAS#,RBC, HGB, HCT,MCV, MCH, MCHC,RDW_CV,RDW_SD,PLT,MPV,PDW,PCT,P_LCR, RETIC%, RETIC_ABS, IRF 2 Histograms for RBC and PLT 2 Scatter grams: 5-part differential scatter gram Eosinophils and Neutrophils scatter gram 2 3-D stereograms • Principles of operation: WBC 5-part:Flow Cytometry(FCM)+ 4 angles laser light scatter WBC Analysis: Optical and impedance measurements RBC/PLT Analysis: Impedance method HGB test: Cyanide-free reagent colorimetry RET test: Flow Cytometry(FCM)+laser light scatter+Chemical dye method • Sampling modes: Auto loader 160μL, Manual mode 160μL, Pre-diluted mode 40ul • Aperture Diameter: WBC 100μmRBC/PLT 80μm • Throughput: Auto loader up to 110 samples per hour Manual mode up to 100 samples per hour • Sampling device: Automatic sampling device with a capacity of 120 samples, 10 samplesX12 racks, auto built-in barcode reader • Data storage: Up to 200,000 sample results with grams • Alarms: Error messages • Display: PC display with Linux system, 14 inch color TFT display • Dimension: 760MMx684MMx676.5MM 6


URINE ANALYZERS

PKL PPC 100 Urine Analyzer SPECIFICATIONS: • Parameters: • Measuring Wavelength: • Sample supply: • Reaction time: • Throughput: • Display: • Memory Capacity: • Strip: • Interface: • Work condition: • Power supply: • Dimension: • Weight:

100

Urine Analyzer pH, Nitrite, Specific Gravity, Ascorbic Acid, Blood, Glucose, Bilirubin, Urobilinogen, Ketone, Leucocytes, Protein Measurement Principle: Dual wavelength reflectance method 3 LED Wavelength (550,620,720nm) manual dipping 60 seconds Normal mode, 60 samples /hour Continuous mode, 125 samples /hour LCD screen 5000 results URIT 10G /11G urine reagent strips Serial port(RS232), parallel port (For external printer), PS/2(For barcode reader) Environmental Temperature: 15-30°C, RH: 20%~80% Adopter 12V DC, 4.0A 290mm x 200mm x 100mm 2kg

PKL PPC 130 Urine Analyzer SPECIFICATIONS: • • • • • •

• • •

130

Urine Analyzer

Reagents: urine reagent strip. Measuring Principle: Reflectance Photometry. Test wavelength: 470nm, 550nm, 620nm, 720nm. Throughput: ≥510 tests/hour in continuous test mode. Measuring Mode: Continuous test and single test modes. It can sense the strip automatically. Urinary parameters analyzed: LEU,Ketone, Nitrite, Urobilinogen, Bilirubin, Protein, Glucose, Specific Gravity, Blood, pH, Ascorbic Acid, • Creatinine, Micro Albumin and Calcium. Display: LCD display with English prompt menu. The test result will be expressed by semi-quantitative • signals and SI unit. Print: Thermal printer built-in to print the results and color of urine. It can also work with • external printer (serial or parallel port). Operating Environment: 15℃~30℃ • • RH≤80% (Recommended) Limit Environment: 5℃~40℃ RH≤80% Storage Environment: -20℃~55℃ RH≤95% Recommended RH ≤80% 7

Control Function: Self-checking, test and trouble-shooting judge are controlled by the microcomputer. Communication port: communication with the computer via the RS232 or parallel port or USB port, and PS/2 port to bar code. Memory: 9999 samples could be reserved. Weight: ≤ 6.1 Kg Outer Dimension: 390mm×340mm×290mm


URINE ANALYZERS

PKL PPC 160 Urine Analyzer 16r0

SPECIFICATIONS: • Parameters: • Measurement Principle: • Measuring Wavelength: • Reaction time: • Throughput: • Display: • Memory Capacity: • Strip: • Interface: • Work condition: • Power supply: • Dimension: • Weight:

alyze

Urine An

pH, Nitrite, Ascorbic Acid, Protein, Specific Gravity, Blood, Glucose, Bilirubin, Urobilinogen, Ketone, Leucocytes Dual wavelength reflectance method 3 LED Wavelength (550,620,720nm) 60 seconds 520 samples /hour LCD screen 5000 results (3000 results with barcode) URIT 10G/11G urine reagent strips Serial port(RS232), parallel port (For external printer), PS/2(For barcode reader) Environmental Temperature: 15-30, RH:20%~80% 100~240V AC,50/60Hz 390mm x 340mm x 290mm 6.5kg

URIN-300

Urin

300

Urine Analyzer

Urine Analyzer • • • • • • • • • • •

SPECIFICATIONS: • Items of Analysis: Glucose (GLU), Bilirubin (BIL), Ketone (KET), Specific gravity (SG), PH, Occult blood (BLD), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Leukocytes (LEU), Ascorbic Acid (VC) • Usable Reagent Strips: Only apply to the strips

produced by the designated factory. Test Speed: 600 items per hour. Memory Mode: Microprinter. Print Paper: The thermal print paper (Width: 57mm, diameter of paper roll: <50mm). Language:English. Relative Humidity: ≦90%. Working Temperature: 0℃~40℃. Power Consumption: <50VA. Security Class: 1 class. Mains: AC220V±15% 50Hz±2Hz Fuse Box: Φ5×20,0.5A Form Dimension: 425×425×385mm

PKL URINE STRIPS 10 or 11 Urinary Parameters : Glucose (GLU), Bilirubin (BIL), Ketone

(KET), Specific gravity (SG), PH, Occult blood (BLD), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Leukocytes (LEU), Ascorbic acid (VC) OTHER SIZES ON REQUEST 8


COAGULATION ANALYZERS

PKL PPC 120

Coagulation Analyzer SPECIFICATIONS:

120

• Principle: dual-magnetic circuit bead method • Parameter: PT (Prothrombin Time), APTT, (Activated Partial Thromboplastin Time), TT (Thrombin Time), FIB (Fibrinogen) Protein C, Protein S, HEP (High-molecular-weight Heparin), LMWH(Low-molecular-weight Heparin), LA (Lupus Anticoagulant), Thrombin factor Ⅱ, Ⅴ, Ⅶ, Ⅹ, Ⅷ, Ⅳ, Ⅸ, Ⅸ, ⅩⅠ, ⅩⅡ etc. • Detector: 2 channels • Incubator: 16 sample positions, 4 reagent positions (tunable incubation time) • Data storage: 500 test results • Display: 5.1” LCD screen • Print: Built in printer & external printer • Input / Output: RS-232 port and parallel interface • Ambient: work temperature: 15~35℃; relative humidity: ≤80%RH • Power: AC100V~240V, 50/60Hz,45W • Dimension: 380mm(W)×340mm(D)×130mm(H) • Weight: 5.9 kg Coagulation

Analyzer

PKL PPC 170 Coagulation Analyzer SPECIFICATIONS: • Principle: dual-magnetic circuit bead method • Parameters: PT (Prothrombin Time) APTT (Activated Partial Thromboplastin Time) TT (Thrombin Time), FIB (Fibrinogen), Protein C, Protein S, HEP (High-molecular-weight Heparin), LMWH(Low-molecular-weight Heparin), LA(Lupus Anticoagulant), Thrombin factor Ⅱ, Ⅴ, Ⅶ, Ⅹ, Ⅷ, Ⅳ, Ⅸ, Ⅸ, ⅩⅠ, ⅩⅡ etc. • Detector: 4 channelsIncubator: 16 sample positions, 4 reagent positions (tunable incubation time) • Data storage: 500 test results • Display: 5.1”LCD screenPrint: Built-in printer & external printer • Input / Output: RS-232 port and parallel interface • Ambient: work temperature: 15~35°C; relative humidity: ≤80%RH • Power: AC100V~240V, 50/60Hz,45W • Dimension: 380 mm(W)×40mm(D)×130mm(H) • Weight: 5.9 kg 9

170er

yz n Anal

ulatio

Coag


MICROPLATE READER

PKL PPC 140 Microplate Reader SPECIFICATIONS:

140

• Plate type: 96-well plate or other plates • Light source: 8V/20W Halogen lamp • Wavelength range: 400-700nm • Filters: 405,450,492,630nm (4 optional filters can be superadded) • Accuracy: ≤±0.01A • Repeatability: ≤1.0% • Linearity: ≤±1.0%(0~1.5A) • Resolution: 0.0001 Abs • Reading speed: 5 seconds single-wavelength (96 wells) • Reading channel: 8 channels • Shaking: high, middle, low speed selectable • Display: Large touch LCD

te Reader

Micropla

• Memory: up to 10000 test results • Printer: Built-in printer or external printer • Output: RS-232 port • Dimensions: 460mm×320mm×210mm • Weight: 8kg

Microplate er

150 Wash

PKL PPC 150 Microplate Washer SPECIFICATIONS:

• • • • • • • • • •

Plate type: U, V or flat-bottom Wash head: 8-probe or 12-probe Wash programs: up to 50 Wash cycles: 1~20 Volume range: 50~450μL/well Residual volume: <1uL/well Dispense precision: CV<2% Soak Time: 1~3660s tunable Pause Time: 0-60s tunable Absorbing Time: 2-10s tunable

• • • •

10

Shaking Time: Display: Keypad: Output:

0-60s tunable 240*128 LCD display 8 touch keys RS-232 port


ELECTROPHORESIS SYSTEM

PKL PPC ELFO Automatic Electrophoresis System SPECIFICATIONS: ANALYTIC METHODS: EMPLOYED MEDIA: PROCESSING CAPABILITY: OPERATIVE CADENCE: DENSITOMETER LINEARITY: POWER SUPPLY ETF: MIGRATION CHAMBER: BUFFER TRAY: STAINING DESTAINING TRAY: INTERFACE: POWER SUPPLY: DIMENSION: WEIGHT:

Serum proteins, Haemoglobins supported cellulose acetate 3 samples(8 tracks) 8 tests/30 min. 8 LED + 8 photodetectors from 0 to 2.5 of D.O. constant voltage or constant current plastic block with titanium electrode automatic filling to optima level automatic filling to optimal level USB 220-240 Vac 50/60 Hz cm 37 x 36 x 36 (LPH) 25 Kg

Available veterinary software also

Automatic

Electropho

ELFO

resis Syste

11

m


CABINETS* LAMINAR FLOW CABINETS

The laminar flow clean bench is a work bench or similar enclosure which has its own filtered air supply. It provides product protection by ensuring that the work in the bench is exposed only to HEPA-filtered air. Laminar flow clean benches are widely used in medical research laboratories, hospitals, manufacturing facilities and other research and production environments.

PKL

PKL

PKL

BIOSAFETY CABINET, CLASS I PKL

PKL

PKL

* Complete Catalogue on request 12


CABINETS* BIOSAFETY CABINET, CLASS II A2

Small dimension, save space; easy to carry with handle. Centrifugal fan, speed adjustable; H14 HEPA filter. Large LCD display: Operators can check detailed status of the cabinet, such as inflow and downflow velocity, work area temperature and humidity, filter pressure, UV working time and filter working time, filter life indicator etc.

PKL

PKL PKL

FUME HOOD 1.UV lamp sterilize the working area.

PKL

2.LCD displayscreen. See the air velocity directly. 3.The fan is inside. Easy to install,save time. 4.The air velocity is adjustable(6 levels). 5.Electrical controlled glass. 6.Removable work surface. Easy to clean.

13


OTHER INSTRUMENTS CO2 INCUBATOR* CONSTANTTEMPERATURE INCUBATOR*

BIOCHEMISTRY INCUBATOR*

DRYING OVEN*

Bench Top Type

* Complete Catalogue on request 14

Floor Type


A FFO R D A B LE D IA G N O S T IC S O LU T IO N S F R O M 1 996 OTHER PRODUCTS:

OUR PRODUCTION: BACTERIOLOGY

CLINICAL CHEMISTRY REAGENTS

CONTROLS

COAGULATION

COAGULATION ANALYZERS

ELECTROPHORESIS

SEMI-AUTOMATED AND AUTOMATED CLINICAL CHEMISTRY ANALYZERS

ANALYTICAL AND TECHNICAL BALANCES AUTOCLAVES

BIOHAZARD CABINETS

URINE ANALYZERS

URINE STRIPS

CENTRIFUGES CHEMICAL CABINETS

WATER ANALYSIS

CHEMICAL REAGENTS FOR LABORATORY USE

CONDUCTIMETER FUME HOOD

ELECTROPHORESIS ANALYZERS

HEMATOLOGY COLORANTS

INCUBATORS LABORATORY GLASSWARE • LAMINAR FLOW CABINETS •

IMMUNOFLUORESCENCE

IMMUNOENZYMATIC

MICROPLATE READERS

MICROPLATE WASHERS

OVENS • PCR CABINETS

PHOTOMETRIC FOOD ANALYSIS

PLASTIC VACUUM TUBES

RADIAL IMMUNODIFFUSION

RAPID TESTS ON CARDS FOR HUMAN AND VETERINARY USE

SEROLOGY

MICROPIPETTES

pH METERS PLASTIC DISPONSABLES • PLATES WITH ELECTROMAGNETIC STIRRING • REFRACTOMETERS • SPECTROPHOTOMETERS • STIRRERS • THERMOSTATS • AND OTHERS

PARAMEDICAL srl Via Irno snc, 84098 Pontecagnano Faiano (SA) - ITALY Vat.: IT03117920656

Tel. +39 089.385027 Fax +39 089.3854479

www.paramedical.it

sales@paramedical.it

Grafiche Capozzoli ·SA · 089 382647


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.