Passive House Plus (Sustainable building) issue 38 IRL

Page 1

INSULATION | AIRTIGHTNESS | BUILDING SCIENCE | VENTILATION | GREEN MATERIALS

S U S TA I N A B L E B U I L D I N G

ABOVE THE CURVE Limerick passive house showcases

precision timber engineering

SLIGO DEEP RETROFIT

Six build specs compared

3D printed buildings

The future or a wasteful distraction?

Cambridge University Student halls fit for a king

Issue 38 €6.95 IRISH EDITION

Embodied carbon

2009526010-08.eps NBW=80 B=20

Warmth, light and sweeping mountain views


OKNOPLAST

ADVERTORIAL

MBC Project

Ph: 01 559 8806 Ph: 021 490 9495 Ph: 076 659 1166

OKNOPLAST IRELAND

Dublin Cork Galway

www.oknoplast.ie

www.mbcproject.ie

2 | passivehouseplus.ie | Issue 29


ADVERTORIAL

OKNOPLAST

Why do modern windows open in? Traditionally, outward opening casement or sliding sash windows have been the go-to solution for most buildings in Ireland and the UK. Between the influence of the British market and architecture, and some old habits, the Irish market has long remained indifferent to the growing popularity of the modern tilt & turn (T&T) technology for inward opening windows. We decided to explore the conventional reasons for using sliding sash & outward opening windows as well as demonstrate the numerous advantages of contemporary tilt & turn windows and debunk some myths surrounding them.

S

liding sash windows would be generally associated with historic buildings following the Georgian and Victorian styles of British architecture. As they were largely made of wood, they offered much room for customised decorations to suit the building’s design. In the late 20th century, outward opening (so-called ‘casement’) windows entered the stage for mass production to Irish homes. Those opened out for easier protection against the harsh Irish & British climate, with driving rain, strong winds and cold, humid air prevailing throughout the year. In the past, either timber or plastic, quite primitive and therefore leaky windows were often used. During the storms, the windows opening outwards sealed better – thanks to the wind pressing the sash tighter against its frame. This layout also protected poor windows against being blown open and breaking. Advanced technology Nowadays, the technology used in tilt & turn windows is far superior to that of casement windows, thanks to greater development capabilities, stronger competition and the combined efforts of manufacturers across Europe pushing each other to keep improving. Better gasket systems and locking mechanisms ensure that good tilt & turn windows are capable of achieving the highest security, air and water-tightness performance of any type of window. Enjoy the view Further by virtue of the above-mentioned technology, tilt & turn windows can now be manufactured to dimensions previously considered impossible for openable windows. Strong hinges (along with steel reinforcements for PVC windows) make fully functional floor-to-ceiling windows a reality. Rather than adapting to the limitations of the glazing, contemporary houses can now be designed creatively without the constraints of small window sizes. Smart design and flexible ventilation Tilt & turn windows are well-known for their exceptional functionality regarding ventilation. Rather than having to open the window fully, the user can simply tilt the window in to allow fresh air into the room. Their smart design also pro-

tects small children against falling out and stops rain from getting in thanks to the tilted angle of the sash. Ease of use & maintenance Since tilt & turn windows can open fully into the room, they can be easily cleaned both inside and outside without the need for using a ladder, dangerously leaning out the window or hiring a window cleaning company. The handle is always easy to reach, regardless of the size of the window or how wide it is open. Myths • Inward opening windows are in breach of building regulations – false. In fact, inward opening windows will in many cases be preferred for fire escapes as they can be made larger and offer a more unobstructed opening when fully open. • What about blinds? – in most European countries, tilt & turn windows are the norm. While many countries also use external window shutters (offered in Ireland by Oknoplast), there are countless options and suppliers for internal blinds. With T&T windows becoming increasingly popular in Ireland, you’ll be able to find good solutions with any respectable blinds supplier. Pleated blinds – known for their simple style and great functionality – would be amongst the most popular choices. • Poor quality – as with any product anywhere, quality of the finished product always depends on good materials and the manufacturer’s capabilities. Many Irish manufacturers with no experience in the more advanced technology of tilt & turn windows have unsuccessfully tried to develop these products on their own, thus creating a bad reputation for T&T in Ireland. • Inward opening windows take up space inside the house – while this is partially true, it does not take into account all of the advantages noted above and the fact that almost every time a tilt & turn window is open for ventilation, it will be tilted rather than opened into the room.

ph+ | oknoplast advertorial | 3


EDITOR’S LETTER

PA S S I V E H O U S E +

Publishers

Temple Media Ltd PO Box 9688, Blackrock, Co. Dublin, Ireland t +353 (0)1 210 7513 | t +353 (0)1 210 7512 e info@passivehouseplus.ie www.passivehouseplus.ie

Editor

Jeff Colley jeff@passivehouseplus.ie

Deputy Editor

Lenny Antonelli lenny@passivehouseplus.ie

Reporter

John Hearne john@passivehouseplus.ie

Reporter

Kate de Selincourt kate@passivehouseplus.ie

Reporter

John Cradden cradden@passivehouseplus.ie

Reader Response / IT

Dudley Colley dudley@passivehouseplus.ie

Accounts

Oisin Hart oisin@passivehouseplus.ie

Art Director

Lauren Colley lauren@passivehouseplus.ie

Design

Aoife O’Hara aoife@evekudesign.com | evekudesign.com

Contributors

Toby Cambray Greengauge Building Energy Consultants Marion Jammet Irish Green Building Council Anthea Lacchia journalist Marc Ó Riain doctor of architecture Mel Reynolds architect David W Smith journalist

Print

GPS Colour Graphics www.gpscolour.co.uk | +44 (0) 28 9070 2020

editor’s letter I

have to stop going down rabbit holes. Over recent weeks I’ve been digging deeper into two particularly labyrinthine tunnels – on building life cycle assessment and thermal comfort standards. Readers will have to wait till our autumn issue before we have something to report in the latter case, but suffice to say it raises some extremely important questions about how to reconcile the need for profound energy reductions against achieving healthy, comfortable conditions in buildings during winter and summer. Questions which the passive house standard may be best placed to answer. I have emerged into the daylight from the life cycle assessment rabbit hole – for now at least – and now comes the business of trying to work out what I’ve learned. The main findings from this experience are manifest in this latest issue of Passive House Plus, in the whole life carbon calculations and building models on six build specs that Tim Martel and Andy Simmonds of the AECB undertook for the Passive House Association of Ireland, working with PHAI board member John Morehead and myself. They’re also manifest in our collaboration with sustainable building consultant John Butler to calculate the embodied carbon of two of the case studies in this issue, and in our interpretation of the revised embodied carbon targets in the RIBA 2030 Climate Challenge. At first glance it looks like a terrible climbdown – RIBA’s 2030 embodied carbon targets for dwellings have risen from 300 to 625 kg CO2e/m2, after all. And the PHAI / AECB analysis came up with some stark findings: all of the six variants of build spec analysed, including a typical cavity wall spec, seem likely to meet the 2030 target – notwithstanding the fact that the analysis did not include certain elements of the spec, such as the building services, other than a heat pump. It will be important to consider the assum-

ISSUE 38 ptions contained within the calculations, for instance with regard to maintenance, replacements and repair, within the sixty-year life span assumed in the RIBA targets. And there is also a legitimate question to ask about whether targets should only be set on a cradle to grave basis. Of course, it’s critically important to think of emissions over the lifespan of a building, and at its end of life. But it’s incumbent upon us to focus on the here and now too, given how little wiggle room we have on emissions if we are to have any chance of preventing the worst outcomes in the climate emergency. So, we must focus on radically reducing the emissions we put into the atmosphere now. That starts by focusing on repurposing buildings instead of building new, where possible. Where we have to build we must try to build smaller, build in the right places, and then ensure that when we build and renovate, we balance minimisation of upfront emissions against minimisation of emissions throughout the building’s life – both for energy use and for maintaining the building – and that we place an emphasis on build quality, repairability and ultimately, de-constructability, to ensure the longest lifespan possible, and to enable future uses of a building’s constituent parts. It’s not easy sticking your neck out and setting targets. RIBA deserves great credit for taking the initiative by including embodied carbon targets in the 2030 Climate Challenge. And there’s a palpable sense of RIBA’s openness, transparency, and keenness to collaborate in advancing our shared understanding what we need to do on embodied carbon. But if the revised 2030 targets risk making business as usual look like sustainable virtue, RIBA has an obligation to act, and to set targets that will force the industry to up its game. Regards, The editor

Cover

Limerick passive house Photo by Eamonn O’Mahony / Studioworks Photography

Publisher’s circulation statement: 7,000 copies of Passive House Plus (Irish edition) are printed and distributed to the leading figures involved in sustainable building in Ireland including architects; consulting; m&e and building services engineers; developers; builders; energy auditors; renewable energy companies; environmental consultants; county, city and town councillors; key local authority personnel; and to newsagents nationwide via Easons. Disclaimer: The opinions expressed in Passive House Plus are those of the authors and do not necessarily reflect the views of the publishers.

ABC Certified Average Net Circulation of 6,417 for the period 01/07/18 to 30/06/19

4 | passivehouseplus.ie | issue 38

About Passive House Plus is an official partner magazine of the International Passive House Association. Passive House Plus (Irish edition) is an official magazine of the Passive House Association of Ireland.


PA S S I V E H O U S E +

EDITOR’S LETTER

ph+ | editor’s letter | 5


CONTENTS

PA S S I V E H O U S E +

CONTENTS COVER STORY

10

28

40

08

10

16

COLUMN In 2017 the government promised it would deliver 50,000 homes over the next five years as part of its Rebuilding Ireland programme. But figures from the first four years show it has fallen well short, writes Mel Reynolds.

INTERNATIONAL This issue features a new nursery school in Paris, built to the Passive House Institute’s low energy building standard.

NEWS A major new passive campus prepares to welcome students in Fermanagh, RIBA loosens its embodied carbon targets for dwellings, and CO2 monitors become a key tool in the fight against Covid-19.

26

COMMENT In his latest column, Dr Marc Ó Riain takes a look back at the some of the first projects to address the phenomena of thermal bridging and thermal bypass in buildings.

6 | passivehouseplus.ie | issue 38


PA S S I V E H O U S E +

50

28

60

CONTENTS

70

CASE STUDIES Above the curve Limerick passive house showcases precision timber engineering

Sometimes it takes the constraints of a challenging site to bring out the best possible design, and that was certainly the case for this Limerick City passive house, where the project team managed to deliver a unique, curving passive house in response to a tricky urban plot.

40

Butterfly effect Sligo deep retrofit delivers warmth, light and sweeping mountain views

Complete with butterfly roofed extension, this fabricfirst renovation has turned a cold and uninspiring 1970s bungalow into a cosy A-rated modern home, with some clever design touches helping to open the house up to wide-angle views and dramatic coastal light.

50

King’s comfort Cambridge choses passive house comfort for Kings’ College students

Most people think of cold, cramped and poor-quality buildings when they think of student accommodation, but two new passive house residences at King’s College, Cambridge are rewriting the rulebook, with their focus on occupant comfort, architectural quality, and an enlightened, long-term view of construction costs.

INSIGHT Six of one An analysis of the embodied carbon from six ways of building a house

Pitch perfect Beguiling Dundee passive house puts wood into woodland

An intriguing new passive house in Dundee takes the traditional ‘box’ form associated with the standard and turns it on its head, using a series of pitched roofs and different claddings to make it feel more like a traditional city terrace than a single dwelling – built with a heavy emphasis on carbon sequestering materials.

60

70

The climate emergency demands that we minimise the energy we use to operate buildings, as well as the energy we use to construct new buildings, where new buildings are needed. A Passive House Association of Ireland-commissioned analysis may start to shed some light on the embodied carbon impact that different build methods can have.

76

MARKETPLACE Keep up with the latest developments from some of the leading companies in sustainable building, including new product innovations, project updates and more.

86

On the 3D printing of buildings

Building physics expert Toby Cambray finds himself unconvinced by the merits of a new home in the Netherlands that has been 3D printed with concrete.

ph+ ph+ | contents | contents | 7 | 7


MEL REYNOLDS

COLUMN

What’s to show from four years of Rebuilding Ireland? In 2017 the government promised it would deliver 50,000 homes over the next five years as part of its Rebuilding Ireland programme. But figures from the first four years show it has fallen well short, writes Mel Reynolds.

R

ebuilding Ireland was launched by former housing minister Simon Coveney in July 2016. The five-year plan comes to an end in July. At the launch, the minister said: “In the next five years we are going to provide about 50,000 more social houses for our people”. The new social homes were to be in “mixed tenure” developments, so “when driving into estates you are not going to know the difference”. The plan had ambitious targets for direct builds by both local authorities and approved housing bodies, as well as massive increases in the housing assistance payments scheme and leased units. In the same year Minister Coveney launched the Rebuilding Ireland housing land map which documented 2,000 hectares of land suitable for housing in state and semistate ownership, with the potential for 50,000 new-build homes on this land. Given the recent ESRI report recommending the government double expenditure on social housing, let’s examine the current programme for social housing and how many homes the state has built since the 2017 launch. Rebuilding Ireland update reports As part of the plan, regular ‘social housing construction status reports’ are issued showing the total number of schemes in progress, what stage each project is at, the numbers of dwellings and locations. Data is now available for four full years from 2017- 2020 inclusive. There are two broad categories of ‘new builds’ which are included by the department: actual new-build units directly built by either local authorities or approved housing bodies (AHBs) on land they own; and turnkey units — these are new homes purchased from private developers. 2017-2020 nationwide The summary table above shows the breakdown between local authority new builds and turnkey purchases for the first four years of the programme. 5,335 new built social housing units for local authorities and AHBs have been completed in four years. Of this 4,063 have been built by the local authorities on state land, an average of 1,000 per annum. In contrast 10,000 new homes (turnkeys) have been purchased from the private sector, an average of 2,500 new homes purchased for social housing per annum. For each direct built

8 | passivehouseplus.ie | issue 38

NATIONWIDE: Rebuilding Ireland 2017- 2020 Social Housing Completion Reports YEAR

Local Authority Builds

Local Authority Turnkey Purchases

AHB Builds

AHB Turnkey Purchases

TOTALS

2020 2019 2018 2017

1343 1088 1238 394

899 1183 767 386

237 350 415 270

2235 2543 1333 654

4,714 5,164 3,753 1,704

TOTAL 2017-2020

4,063

3,235

1,272

6,765

15,335

Total Builds (LA + AHB) 2017- 2020 Incl.

5,335

Total Turnkey Purchases (LA + AHB) 2017- 2020 Incl.

10,000

Table: Summary of new build social homes nationwide. Source “Rebuilding Ireland Social Housing Status Reports 2017-2020 incl.”

home, two are purchased from the private sector. Confusingly, some Part V acquisitions — under which developers are required to set aside a certain proportion of dwellings for local authorities — are also included in these totals. Most new social homes are indistinguishable from normal estate homes because they are normal estate homes. 2017- 2020 Co Dublin Meanwhile, in four years just 1,931 direct built social homes have been completed by local authorities and AHBs in Co Dublin. The four Dublin local authorities built just 341 local authority homes on average each year. The figure for purchases is slightly higher: a total of 2,687 new turnkey units have been purchased over the four years, an average of 672 per annum. Remarkably, output by the four Dublin local authorities last year was similar to 2017. The cumulative total for Dublin City, Fingal and South Dublin County Councils was 267 local authority dwellings. Dún Laoghaire-Rathdown, the most unaffordable location to rent or buy in Ireland, saw no new-build local authority homes built or purchased last year. Current supply of social affordable housing is in stark contrast to the demand figures. The main Record of Qualified Households (or the social housing waiting list) combined with housing assistance payment (HAP) levels, suggests a current demand for affordable and social housing at more than 120,000 households nationwide, with 40,000 of these in Co Dublin alone. In March of this year the most recent Rebuilding Ireland update report press announcement said: “A total of 7,827 new social homes were delivered in 2020 including 5,073 new build homes”. The headline figures suggest impressive levels of build activity. Classifying new build purchased units as ‘new builds’ in the Rebuilding Ireland plan,

along with lumping in AHB activity into this figure, flatters state build activity and gives soundbites for media briefings. Stripping out Part V and turnkey new home purchases gives a more realistic indication of statebuild activity on state land. The government has increased social housing direct build output, from 394 units nationwide in 2017 to 1,343 in 2020, a considerable increase albeit from a very low base. AHB build figures have not increased to the same extent, dropping back to a low of 237 units from a high in 2018 of 415 homes completed. However, the bulk of the increase has occurred in areas of lower demand. Analysis confirms much lower levels of state activity, particularly direct builds on land the state already owns, in the capital. Last year in County Dublin 267 local authority new-build homes were completed on state land, similar to 2017 levels of state build activity. The bulk of headline increases has been in the purchase of new homes from private developers. The turnkey purchase programme had expanded from 1,040 combined in 2017 up to a high of 3,756 in 2019, before dropping back to just over 3,000 in 2020. If the government is serious about increasing the supply of direct build homes on state land, it must first remove the spin and accurately measure the gap between aspiration and delivery. n A fully referenced version of this article is online at www.passivehouseplus.ie Mel Reynolds is a registered architect with more than 25 years of experience in project management, conservation, urban design and developer-led housing. He is also a certified passive house designer.


Stop building in the past. Embrace the FUTURE

INSULATED FOUNDATION

Ireland’s Only NSAI Certified Insulated Foundation System • Guaranteed thermal performance that lasts a lifetime • Sustainable, recyclable and EPD verified • Designed to exceed nZEB & Part L 2019 • Fully engineered for each project

KORE Insulated Foundation System CERT No. 20/0424

• NSAI Certified

Learn more by visiting www.kore-system.com Join the KORE Resource Centre for product design guides, technical data and BIM object files. Consult with KORE for project evaluations and technical calculations at no cost.

HIGH PERFORMANCE

EPS


INTERNATIONAL PAS S I VE & EC O B U I LDS F R O M AROU ND THE WORLD IN BRIEF Building: 1,500 m2 nursery school Location: 13th arrondissement, Paris Building method: Timber frame with straw insulation Standard: PHI Low Energy Building Standard

10


I N T E R N AT I O N A L

FRANCE

Photos by Charly Broyez Planchers et toitures en CLT

Planchers et toitures en CLT

Murs à ossature bois & Isolation Paille et Laine de bois

Murs à ossature bois & Isolation Paille et Laine de bois

Planchers et toitures en CLT

Planchers et toitures en CLT

Murs à ossature bois & Isolation Paille et Laine de bois

Murs à ossature bois & Isolation Paille et Laine de bois

Voiles en Béton armé

LEFT Voiles en Béton armé

PRINCIPESSCHOOL, CONSTRUCTIFS BANK NURSERY OssaturePARIS Bois

Voiles en Béton armé

T

Ossature Bois

Axonométries de principe

Ossature Bois

he challenge for the designers of this new nursery school, set within Paris’s Left Bank, was to create a space that would be warm, light-filled and conducive to learning — but in a dense city centre environment that is overlooked by tall, monolithic apartment blocks of the 13th arrondissement. The building’s PRINCIPESdesigners, CONSTRUCTIFSLA Architectures, achieved their goal Axonométries de principe beautifully by breaking down the building into multiple volumes. PRINCIPES CONSTRUCTIFS Voiles en Béton armé Ossature Bois While not ideal for meeting the passive house standard — it means Axonométries de principe a larger surface area from which heat can escape, and more junctions that need to be sealed for airtightness — it does help to create a more human-centred building in the middle of an otherwise imposing streetscape. Another technique employed by the architects to bring light into the school was Le Corbusier’s beloved “architectural promenades”. These inner streets meander through the building, and with their PRINCIPES CONSTRUCTIFS glazed walls, open up the space and allow occupants to look out Axonométries de principe

through the classrooms to the courtyard beyond. Indeed, the school has been designed so that there is a view to the outside at almost every point. LA Architectures also placed a strong emphasis on natural materials here: the walls are of timber frame construction and insulated with straw, with floors and interior walls of cross-laminated timber. There is also a green roof, timber cladding, and a brickwork that was made in one of Paris’s last traditional old kilns. The building did not quite meet the passive house standard — at 28 kWh/m2/yr, its demand for space heating is outside the passive benchmark of 15 kWh/m2/yr — so instead it was certified to its less onerous cousin, the Passive House Institute’s low energy building standard (which only requires 30 kWh/m2/yr). But all in all, the thoughtful approach to materials, natural light and occupant comfort here must make this one of the most joyful places for children to learn in Paris’s busy urban centre.

ph+ | france international | 11


12


Join us on the road to sustainability 0 Book your CPD today. Email info@ecocem.ie

|

+353 1 678 1800 |

ecocem.ie


WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on www.passive.ie

14


SHOWROOMS: CORK, DUBLIN, GALWAY & BELFAST UNPARALLELED CHOICE OF PASSIVE CERTIFIED PRODUCTS – OUTWARD OPENING, INWARD OPENING, UPVC, ALUMINIUM, ALUCLAD

GROUND BREAKING U-VALUES FROM AS LOW AS 0.47W/M2K

T. 064 7751151 E. info@munsterjoinery.ie

www.munsterjoinery.ie WINDOWS & DOORS


NEWS

PA S S I V E H O U S E +

NEWS

SCALE UP RETROFIT GOALS AND REALISE HUGE SOCIETAL BENEFITS, NEW REPORT SAYS

T

he International Energy Research Centre (IERC) at the Tyndall National Institute, UCC has called on the government to exceed its current home retrofitting ambitions in terms of both speed and scale in order to “leverage the environmental, social and economic benefits for the Irish economy, which could be in the region of €600 million per year.” A new report from the centre presents the potential direct and indirect benefits of a nationwide cost optimal retrofitting programme, which would upgrade homes to a B2 energy rating, as targeted under the Climate Action Plan. The Irish government plans to upgrade 500,000 homes to this level by 2030, but the IERC report goes further and estimates the maximum possible benefits if Ireland were to retrofit all of its 1.6 million homes with an energy rating of C or lower. “An investment in retrofitting is an investment in the environmental, societal, and economic infrastructures of Ireland, from the ecological air, water and soils, and the health-

care and social welfare systems, to the energy generation and supply system,” it concludes. “This report recommends exceeding current retrofitting ambitions in terms of speed and scale, due to both the number of benefits available and the magnitude of potential financial returns.” The potential reduction in energy use and associated carbon emissions are estimated to be around 53 terawatt hours and 12.7 million tonnes respectively if Ireland retrofitted 1.6 million homes. In addition to the energy saving, the report concludes that realising this ambition would also bring about a rapid reduction in fuel poverty, while lower energy bills for households would lead to a better quality of life, with €4.5 billion of additional annual disposable income within the Irish economy. There is also a benefit to the exchequer in annual savings on social welfare spending, such as household fuel-allowances. “Housing is a fundamental requirement for life and good quality housing is critical

to human health and wellbeing,” said IERC’s policy and regulatory innovation lead, Dr Piyush Verma. “Policymakers need to understand the non-traditional benefits as well as stakeholders involved in home retrofitting.” The report also highlights the significant benefits that could be accrued through VAT on the retrofit works, property tax due to increased property values, and stamp duty due to increased values of properties sold each year. It also found that the increased health and wellbeing benefits could save the Irish economy up to €600 million annually, through gains in productivity and output, reduced sick leave and absenteeism, and reduced burden on the healthcare and social welfare systems. Annual savings on the reduction of hospital admissions alone, could be over €20m for the HSE, and over €2m to patients, the report found. Read the full paper at https://www.tyndall. ie/residential-retrofit-renovation.
•

Erne Campus is world’s largest passive house premium building

S

outh West College’s new Erne Campus building in Enniskillen, Co Fermanagh, is the world’s largest, and the first educational building, to be certified to the passive house premium standard, the Passive House Institute has confirmed. The 8,200 m2 new build project is also the first building in the UK to achieve both passive house premium and BREEAM outstanding accreditations. Designed by Hamilton Architects and constructed by local firm Tracey Brothers Limited, the four-storey campus is fully funded by Northern Ireland’s Department for the Economy and will accommodate in excess of 800 full-time students, 2,000 parttime students and 120 staff when it opens in September. South West College chief executive, Michael McAlister, said: “From the earliest stages of planning, achieving sustainability and reaching the passive house premium standard has been central to the Erne Campus project. Achieving this accreditation is a significant milestone and one that we take great pride in. “Renewable energy and sustainability have been at the forefront of college delivery

16 | passivehouseplus.ie | issue 38

for several years, both in terms of the curriculum we offer to students and our own construction practices. The world-class Erne Campus will deliver a unique curriculum, education and a training programme specialising in renewable energy and sustainability in a live working environment. We hope that in this way we can also advance sustainability in construction across these islands and beyond.” Meanwhile Tomás O’Leary, managing director of MosArt Architects and passive house consultant on the project, added: “I am delighted to announce the official certification of the recently completed Erne Campus at South West College, Enniskillen, as the world’s largest passive house ‘premium’ educational building. “The project sets a new standard for educational buildings across the globe in terms of energy efficiency, year-round comfort, and indoor air quality. It will act as a beacon and a source of inspiration for building designers everywhere in delivering on much-needed dramatic reductions in carbon emissions from the built environment.” Passive house ‘premium’ is an advanced

version of the standard that requires buildings not only to meet the classic passive house standard for fabric efficiency and ventilation, but also to generate 120 kWh/ m2/yr of renewable energy on site. • (below) Pictured at the new £30 million Erne Campus in Enniskillen are (left to right) South West College’s chief executive Michael McAlister, Northern Ireland economy minister Diane Dodds, and MosArt managing director Tomás O’Leary.


PA S S I V E H O U S E +

Electric Ireland & SuperHomes aim to retrofit 35,000 homes

NEWS

Passive House Plus editor to speak at TEDx

P

(above) Pictured at the Electric Ireland SuperHomes launch in Dublin at a recently completed SuperHome are (L-R) Electric Ireland SuperHomes managing director Stephen O’Connor; Electric Ireland executive director Marguerite Sayers; environment minister Eamon Ryan TD; and Tipperary Energy Agency chairperson Seamus Hoyne.

E

lectric Ireland and Tipperary Energy Agency have announced a new joint venture, Electric Ireland SuperHomes, with the ambition of delivering 35,000 deep energy retrofits by 2030. The partnership will directly create 200 jobs over the next five years as well as supporting the development of hundreds more jobs indirectly through building contractors and other partners, a press statement accompanying the launch said. SuperHomes is the existing residential division of energy adviser and social enterprise Tipperary Energy Agency. SuperHomes advises homeowners throughout all stages of their energy retrofit project via a “one-stop-shop” service. The service covers energy survey and retrofit design, the selection, appointment and supervision of a qualified building contractor, and management of the SEAI grant application and related paperwork. SuperHomes has advised on 30 per cent of the deep retrofits delivered to date in Ireland. Electric Ireland, meanwhile, is Ireland’s largest energy supplier with over one million customers. The focus of Electric Ireland SuperHomes will be on whole-house, multi-measure deep retrofits, rather than individual energy upgrades, to bring homes to a minimum B2 BER. Retrofit measures will include air-to-water heat pumps, heat recovery or demand-controlled ventilation, airtightness works and insulation.

“To meet Ireland’s ambitious climate aims we need to radically improve the energy performance of our built environment,” said Stephen O’Connor, managing director of Electric Ireland SuperHomes. “Domestic heating accounts for six million tonnes of CO2 every year or about 10 per cent of Ireland’s total emissions, while 80 per cent of our housing stock has a BER energy rating of C or worse. Living in a warm, healthy, energy efficient home is the aspiration of everyone, but a retrofit project can be daunting and complex. Electric Ireland SuperHomes will be a trusted adviser to homeowners nationwide embarking on this journey.” Meanwhile Seamus Hoyne, chairperson of Tipperary Energy Agency’s board, commented: “Tipperary Energy Agency launched the SuperHomes Retrofit programme in 2015 and since then has successfully retrofitted hundreds of Irish homes. Having built a high quality one-stop-shop retrofit service we are now partnering with Electric Ireland to dramatically scale up the delivery of this service across Ireland. Our mission is to lead the delivery of sustainable energy solutions in Tipperary and beyond, by advocating, educating and innovating on climate action. The Electric Ireland SuperHomes partnership will deliver on this mission within the residential sector, and we will continue to lead change in other sectors as we chart a path to our zero-carbon future.” •

assive House Plus editor Jeff Colley will be speaking at the TEDx Tralee event on 15 October. With a working title of “Virtuous luxury: how green buildings can improve your life”, Jeff will be presenting the counter-intuitive case that, in the case of buildings, taking radical climate action can enhance rather than compromise quality of life. Sustainability will also be represented at the event by sustainable designer Chris Barrett, who will be drawing from his experience in biologically-inspired product design, integrating reclaimed and natural materials, and traditional musician Breanndán Ó Beaghlaoich, who will speak about the importance of enabling indigenous peoples to live off the land in their area in order to maintain their cultures. Other presenters at the event, to be held in the Siamsa Tíre Theatre in Tralee, will include disability perception advocate Alan Carrigan; public relations consultant Anthony Garvey; human resource consultant Caroline McHenry; beauty therapist Christine Duff; motivational speaker Ciara McCullough; entrepreneur Colm O’Brien; social entrepreneur Edel Lawlor; television producer Grett O’Connor; life coach Jennifer Maher; artist and writer Kate Moore; philanthropist Ken Gibson; sports coaching developer Liam Moggan; writer, consultant, communicator, artist and advocate Nadia Ramoutar; and online educator Stephen Treacy. TEDx is a grassroots initiative, created in the spirit of TED’s overall mission to research and discover “ideas worth spreading.” For more information visit www. tedxtralee.ie. •

ph+ | news | 17


NEWS

PA S S I V E H O U S E +

Cavity wall builds can meet RIBA carbon targets, new analysis suggests

Words by Lenny Antonelli and Jeff Colley

A

detailed analysis of the embodied carbon of six common build types has indicated that dwellings built with business-as-usual build specs of cavity wall construction and strip foundations may be able to meet the revised embodied carbon targets for dwellings in RIBA’s 2030 Climate Challenge – which the RIAI is using as the basis for the RIAI 2030 Climate Challenge, set to be published this year. The RIBA document has come under scrutiny recently after its 2030 embodied carbon target for dwellings was eased from 300 to 625 kilograms of CO2 equivalent per square metre (kgCO2e/m2). The analysis, published elsewhere in this issue of Passive House Plus, was commissioned by the Passive House Association of Ireland (PHAI) and undertaken by the Association for Environment Conscious Building (AECB). A house design for a social housing unit with 84 m2 gross internal area (GIA) provided by Cork City Council was analysed using six different variations of wall and foundation specs. The analysis also included specs for roof, intermediate floors, stud walls, windows, and an air-to-water heat pump, but excluded items such as fixed furniture and equipment, ventilation, heating and water distribution systems, tiling and staircase. The base case included two variations – a brick clad cavity wall, and a rendered block cavity wall, both on conventional strip foundations. The brick clad option totalled 526 kgCO2e/ m2 GIA, indicating it would likely comply if the missing elements were included. The rendered cavity wall build and a single leaf 215 mm block with external insulation, both on conventional foundations, respectively totalled 496 and 492 kgCO2e/m2. Meanwhile a variant including cellulose-insulated timber frame with cement boards and insulated foundations integrating 50 per cent GGBS totalled 369 kgCO2e/m2. RIBA has defended its decision to make the embodied targets in its 2030 Climate Challenge significantly easier to achieve. The previous target of 500 kgCO2e/m2 for non-domestic buildings has also been replaced by two separate targets: 540 kgCO2e/m2 for schools and 750 kgCO2e/m2 for offices. The 2025 target for operational energy in dwellings has been tightened from 70 to 60 kWh/m2/ yr. However, it is the change to the embodied carbon target for domestic buildings that has

raised most eyebrows. “Seeking radical, systemic change is one of the core values that brings us together as a network,” Joe Giddings of the Architects’ Climate Action Network told the Architects’ Journal. “So many, including myself, were disappointed to see RIBA climbdown on their targets for 2030.” However, RIBA defended the changes, and said the new targets aligned it with similar benchmarks set by other organisations. “When we launched the 2030 Climate Challenge two years ago, we set initial targets, but were clear that these would evolve,” said RIBA president Alan Jones. “Since then, industry knowledge and data has significantly increased, and we have worked closely with key organisations such as LETI, IstructE, UKGBC and the Whole Life Carbon Network to ensure that our embodied carbon targets and approaches are aligned and consistent. “The embodied carbon targets have been refined based on more accurate benchmarks, but the 2030 targets for operational energy and potable water use remain unchanged, and some sector-specific 2025 targets for energy consumption have been tightened. “To successfully reduce the huge negative impact of construction, we must collaborate across the entire sector and, as architects specifically, change our approach to designing buildings. These targets are ambitious, but achievable. I urge all practices to sign-up to the challenge. We need to attempt to achieve these targets on our projects now.” The LETI (London Energy Transformation Initiative) has set it owns benchmarks for embodied carbon, and RIBA’s new targets coincide with a ‘B’ rating under LETI’s system, but LETI also assigns more ambitious A, A+ and A++ ratings for buildings that achieve under 450, 300 and 150 kgCO2e/m2 respectively. However, while LETI’s targets exclude the up-front carbon footprint of on-site renewable electricity generators, RIBA includes them, leading to questions about how comparable the two benchmarks are. Speaking to Passive House Plus, the passive house architect Mark Siddall, a technical advisor to both the AECB and the Passivhaus Trust, said he thinks the previous target of 300 kgCO2e/m2 was very onerous, given that it includes building life cycle stages A (product

81% Advertise with us.

have made decisions on projects because of ads in the magazine*

18 | passivehouseplus.ie | issue 38

*source, Passive House Plus Irish edition 2019 reader survey

stage and construction process) through to C (end of life). However, he questioned whether the embodied carbon of on-site renewable energy systems should be included in the target, as he said this would mean a theoretical dwelling with no “bolt on” renewable energy systems, and that only pays rudimentary attention to the embodied carbon of its building fabric, could produce a similar embodied carbon score to a dwelling with low embodied carbon fabric and a solar PV system. He gave the example of his Larch Corner passive house in Warwickshire, for which the solar PV system accounted for about one-quarter of the stage A embodied carbon score. He suggested that the embodied carbon of on-site “bolt on” renewables such as solar PV should be reported, but not included in the main target. The RIBA 2030 requirements require calculation of embodied carbon in accordance with the RICS guidance document, ‘Whole life carbon assessment for the built environment’, with analyses to include including a minimum of 95 per cent of the cost, and seven of eight building element groups, including substructure, superstructure, finishes, fixed FF&E, building services and associated refrigerant leakage. The exception is external works. Speaking to Passive House Plus, RIBA sustainable development advisor Jess Hrivnak said: “We appreciate many projects won’t be undertaking whole life carbon assessments as part of normal project programme. The intention is not that projects should do these retrospectively for the sole purpose of data collection.” Hrivnak said RIBA is interested in understanding if no whole life carbon assessment took place, why not. Or – if high level embodied carbon evaluation was undertaken – the scope and stage that any calculations were carried out. “It is just as important for us to understand the ‘why nots’ – the barriers and limitations – as it is to increase whole life carbon datasets of completed projects.” said Hrivnak, “It is only through collaborative data sharing, and being transparent about boundaries, that we can increase industry knowledge and collective improve the accuracy and precision of our predictions of the impact of the built environment.” •

To enquire about advertising, contact Jeff Colley on +353 (0)1 2107513 or email jeff@passivehouseplus.ie

www.passivehouseplus.ie


PA S S I V E H O U S E +

NEWS

NORDAN WINDOWS & DOORS Sustainable Design, Energy Efficient, and Virtually Zero Maintenance

With secured by design accreditation and weather performance far exceeding the standard, it’s clear that no one can like NorDan can. Visit our showrooms in Cork, Dublin or Galway to experience the NorDan difference first hand 38 North Point Business Park, New Mallow Rd, Cork City Bluebell Industrial estate, Bluebell, Dublin 56b Briarhill Business Park, Briarhill, Galway - Opening July 2021

www.nordan.ie

ph+ | news | 19


NEWS

PA S S I V E H O U S E +

#BuildingLife: “Reducing embodied carbon must become a priority,” says Dublin city architect Ali Grehan look at how we live and at our values as a society. Older buildings are too often seen as ugly or inefficient. We need to change that perception that new is always better. It is a learning curve, and it is challenging for all. But it is also a fantastic opportunity to be creative and innovative.

(above) Dublin city architect Ali Grehan.

I

n the #BuildingLife ambassador spotlight series, Passive House Plus is profiling leaders who have endorsed the Irish Green Building Council’s call to address the environmental impacts of buildings across their lifecycle. In this second interview of the series, Ali Grehan, city architect for Dublin City Council tells us more about the campaign and why she is supporting it.

PH+: Why did you choose to become a #BuildingLife ambassador? AG: As city architect, I am passionate about the quality of our built environment. Our buildings can contribute to addressing climate change or accelerate it. It all depends on the direction we take. #BuildingLife aims at tackling embodied carbon. These emissions result from mining, quarrying, transporting and manufacturing building materials, in addition to constructing buildings. It is a tricky and interesting issue. Once a building is constructed, the embodied carbon is there. You can make a building more energy efficient in its use, but you cannot (de)retrofit embodied carbon. We need to shift the conversation from focusing exclusively on operational energy to the environmental impact of buildings across their lifecycle. This means accepting there is an embedded value in existing buildings. How do we retain that value? If we demolish a building, how can we reuse materials? When designing new buildings, how can we minimise the environmental footprint? To address climate change, we must

20 | passivehouseplus.ie | issue 38

PH+: What are you hoping to achieve with the #BuildingLife campaign? AG: New tools and policy recommendations will be developed as part of the campaign. But the underlying issue is far more important. It is about reaching people and increasing the understanding of the impact of buildings on our planet. Reducing embodied carbon must be part of every discussion in the industry. It must become a priority for building professionals, funding bodies and clients. And it should not be a binary discussion. It is not about tackling climate change or building new homes. Meeting our housing targets is critical, but it must be done in a better way. We must be more creative and ensure it does not contribute to climate change. PH+: Can you explain a few ways in which Dublin City Council is working towards a sustainable built environment? AG: We have an extensive retrofit programme. About 8,000 flats must be retrofitted to a building energy rating (BER) of B2 by 2050. This is a huge challenge. It is also an opportunity to reduce our emissions, improve buildings’ condition and address social needs. As part of our retrofit programmes, we often amalgamate adjacent bedsits to create one-bedroom apartments and look at filling gaps with new buildings where possible. This allows us to bring back bedsits into use and to improve [the] public realm. We have also started to look at embodied carbon as a core principle. But clients and funding bodies must support that move. Unfortunately, embodied carbon is not yet part of the discussion when considering whether demolition and building new is the best option. #BuildingLife is a project led in Ireland by the Irish Green Building Council. The initiative aims to achieve the mix of private sector action and public policy necessary to tackle the whole-life impact of buildings. Learn more at www.igbc.ie. •

Passive House Plus hosts online event

P

assive House Plus has hosted its first online event, a roundtable webinar on thermal breaks. The event, ‘Thermal breaks: freedom of architectural expression vs building physics’, was held on 8 June, and featured a number of the UK and Ireland’s leading experts on thermal bridging. Over 550 people registered for the event, which is available to view on the Passive House Plus YouTube channel. The event, which was sponsored by Farrat, kicked off with three PechuKucha style presentations: Passive House Plus columnist and Munster Technological University lecturer Dr Marc O’Riain traced the history of thermal bridging, before Enhabit associate director of building physics & PAS 2035 technical lead author Dr Sarah Price talked about thermal breaks in a retrofit context, and Elemental Solutions director Nick Grant drew from his experience on how to make a complicated subject like thermal bridging simple. The second session started with Bow Tie Construction director Rafael Delimata giving the contractor’s perspective, before PhD candidate Joe Pemberton & Will Swan of the University of Salford gave a joint presentation on the university’s research on thermal breaks, and Farrat commercial manager Chris Lister gave a presentation on the company’s proprietary thermal break solutions. The sessions were broken up by two roundtable panel discussions, which also included Pritchard Architecture RIBA client advisor and architect Ruth Butler, Build Collective director Tara Fraser, Wain Morehead Architects director John Morehead, Renfrewshire Council housing energy officer David Stevenson, and Architype technical associate Robert White. Passive House Plus surveyed the attendees after the event. Eighty five per cent of respondents said information from the event will probably or definitely influence decisions they take on construction projects. Passive House Plus ran the event as a pilot and is considering running further events in the future. To view a recording of the event, visit https:// bit.ly/3hjBMQl. • (below) A slide from Dr Sarah Price’s presentation indicates the significance of thermal bridging at windows in heat loss terms.


Now taking orders for 2022 Call 0906 630583 for more

P A S S I V EP H AS OSUI SVEE+ H O U PH S EA+I U PNDEAW TS E

Innovative design tailored to your needs • BER A Rated • Certiied Near Zero Energy Building • Passiv Level Buildings • Sustainable Buildings • Bespoke Design • Turnkey Solution la offices • Modular housing & large • Home working offices • Community centre’s & amenity facilities • Leisure spaces • Extra space accommodation • National Award Winners

A rated built off-site bespoke extension TEL: 0906 630583 / 01 9011680 E: INFO@LIDANDESIGNS.COM Find us on Facebook at Lidan Designs or visit www.lidandesigns.com ph+ | news | 21


INGEBWCS U P D PA S TS E I V EP H AS OSUI SVEE+ H O U S E +

How to scale up energy renovation The government’s target of retrofitting half a million homes by 2030 may seem daunting, but the Irish Green Building Council is working on a series of initiatives to help make it a reality, as the group’s Marion Jammet reports.

B

uildings are one of the biggest contributors to climate change in Europe and account for 36 per cent of CO2 emissions. In Ireland, 1.5 million buildings are energy inefficient and must be retrofitted by 2050. The Climate Action Plan set the ambitious target to retrofit half a million homes to a building energy rating (BER) of B2 by 2030. This is almost six homes being retrofitted every hour for the next ten years. It represents a significant jump from current low levels of deep renovation. Last year, approximately seven homes a day were retrofitted to that standard. The decarbonisation of the existing building stock presents enormous challenges and requires mobilising forces at all levels towards this goal.

Driving change locally: the role of local authorities Quality data on the impact of retrofit programmes (including their wider benefits) is critical to ensure targets are reached and reduction in CO2 emissions is delivered. It is also key to support decision-making. In 2017, the Irish Green Building Council (IGBC), alongside other green building councils, tried to source data on the impact of energy renovation programmes across Europe. The aim was to identify best-practice and programmes that should be replicated. Within weeks it became clear very little data was available and that this data wasn't captured in a standardised way. To address this issue, the IGBC is working with local, national and European stakeholders to develop an Energy Renovation Framework. This framework allows local authorities to track and measure the impact of their renovation programmes. It covers a wide range of indicators, from energy efficiency to CO2 emissions, indoor air quality, fuel poverty and jobs creation. Thirty-two European local authorities are currently testing out how measuring the holistic benefits of energy renovation can help in addressing climate change. In Ireland, the framework is being tested by Dublin City Council, while Cork City Council, and Kilkenny and Laois County Councils, are providing additional feedback. When launched, the framework will allow local authorities to better identify and share successful retrofit initiatives. Better quantifying the impacts of retrofit programmes will also help local authorities make a better business case for scaling-investment in these programmes. Finally, local authorities will be able to use this quality data on the co-benefit of energy renovation to better engage with citizens and support the renovation wave. If used at scale, the framework can help to raise awareness in society about the benefits of energy renovation and make it more desirable. Enabling energy renovation: the role of one-stop-shops To increase the depth and rate of energy renovation, retrofit must also be made easier and more affordable. Homeowners who want

22 | passivehouseplus.ie | issue 38

to retrofit often do not know what to do or where to start. Over the last few years, the IGBC has researched tools to support homeowners in their renovation journey. In 2020, with SEAI support, we piloted a building renovation passport on 20 single-family dwellings across Ireland. Building renovation passports are a new concept in Europe. They provide homeowners with a clear plan to improve their home. If a homeowner doesn’t have the money to do all the work now, they can do it bit by bit in a way that works towards an end goal of a very energy efficient and comfortable home. To increase trust in the outcomes of energy renovation, the IGBC, in partnership with Limerick Institute of Technology, has also worked on recommendations on how and why a register of energy renovation advisors should be set up. The aim is to have network of skilled, trusted and independent local intermediaries who can support homeowners at all stages of the retrofit journey. Based on this work, and after extensive stakeholder engagement, the IGBC is proposing a digital platform and marketplace to connect homeowners with end-to-end services. The first phase of development will be a website for retrofit to be launched in September. It will provide homeowners with information on the renovation potential of their dwelling, including a building renovation passport. It will also include information on grants and finance available, as well as a register of energy renovation advisors. The objective is bridging the gap between a technical supply side and complex customer demand side to create a clear customer proposition. This should be based on high quality retrofit, at an affordable price, with seamless delivery. Building capacity within the industry To facilitate energy renovation upskilling the IGBC has launched the Build Up Skills Advisor app. Through the app, building professionals and construction workers can identify energy renovation training courses that suit their needs in one click. Webinars on high quality renovations are also available on the Irish Green Building Council's learning hub. To further support upskilling, the IGBC is developing a “training clause” to be used in public tenders. Training clauses allow buyers to require companies winning NZEB projects (new build and retrofit) to train their staff (construction workers and site supervisors) in energy efficiency. This type of clause is currently in use in northern France, where it has led to significant improvement in quality. The clause will be piloted in Ireland in late 2021. The Energy Renovation Framework will be launched at the IGBC’s annual renovation conference on Friday, 15 October. For further information on the Framework, the retrofit platform or training courses, please visit www.igbc.ie or contact marion@ igbc.ie. •


PA S S I V E H O U S E +

NEWS

Passive House Institute Certified Mechanical Ventilation with Heat Recovery Systems With Self Balancing technology for better energy efficiencies. Brink. Quiet, efficient and technologically advanced complete MVHR Systems.

Say hello to:

Say goodbye to: • Mould, mildew and condensation • Stale, foul, unpleasant, humid air • Musty and unpleasant odours • High humidity levels

• Warm, freshly filtered air • Reduced asthma, hay fever and allergy triggers • Lower energy bills and emissions • Guaranteed, Dutch quality

Brink systems are also fully compatible with Ubbink’s Air Excellent air distribution systems. Air Excellent’s clever, push-together connection system combines unsurpassed ease of installation, with incredible levels of airtightness.

We only offer designs and systems that are fully NZEB and TGD Part F compliant. Learn more at www.BrinkHRV.com/newbuild Brink and Ubbink are distributed throughout Ireland by Kernohan Distribution. Web: www.iakonline.com or www.brinkhrv.com | Email: info@BrinkHRV.com or info@iakonline.com

Coming soon. Underfloor heating packages. Intuitive underfloor heating packages with high performance Valsir multilayer PEX pipe and smart self calibrating controls from Danfoss. Combine your MVHR system with an underfloor heating package for even greater savings. Visit www.BrinkHRV.com/underfloorheating to find out more.

Made from 100% recycled composite cardboard. AM Ecoboard is a multi-purpose building board. It is: • Soundproof (31dB) • Fire rated (30 minutes) • Airtight • Formaldehyde free • Mould and mildew resistant • Suitable for multiple uses

Contact sales@acousticmaterials.ie or call (01) 2015746

www.acousticmaterials.ie ph+ | news | 23


NEWS

PA S S I V E H O U S E +

Growing use of CO2 monitors to slow Covid spread While the Irish government is delivering CO2 monitors to schools to help prevent the spread of Covid-19, and some European regions have mandated the use of such monitors in all buildings open to the public, the UK has yet to introduce such measures and has removed the requirement for mask-wearing in schools. By Kate de Selincourt

T

he Irish government is to provide CO2 monitors to all primary and secondary schools, and will support schools that need to upgrade their ventilation to help protect against airborne transmission of Covid. The announcement came as the US Centres for Disease Control (CDC) published research suggesting that increasing ventilation may reduce Covid infection in schools by as much as 35 per cent. Meanwhile, the UK government is under increasing criticism for failing to implement equivalent mitigation measures, and for actually removing the requirement to wear masks in schools in England, at a time when incidence of the highly infectious Covid Delta variant was rising more quickly among school age children than any other age group. The importance of ventilation and maskwearing in limiting Covid transmission in schools was highlighted by the findings from a US study. One hundred and seventy US schools responded to a survey about mask wearing, ventilation and air cleaning practices, and responses were compared against the official records for school Covid outbreaks, and against the community Covid incidence rates locally at that time. Around half the schools reported that steps had been taken to increase ventilation, and in these schools, there were 35 per cent fewer outbreaks. Air cleaning (for example via HEPA filtration) appeared to reduce the risk still further, to 48 per cent below the ‘no measures’ level, but numbers here were quite small, so this result is less clear. Mask wearing also showed a strong protective effect, with schools that required staff to wear masks reporting 37 per cent fewer outbreaks. The effect of mask wearing by children did not appear as strong. However, these schools were all primary age or kindergarten, and younger children may be expected find it hard to wear a mask effectively and consistently. i Irish schools In May, Ireland’s Department of Education announced that “to support schools... to

24 | passivehouseplus.ie | issue 38

identify rooms which may have inadequate ventilation and to optimise comfort levels” it would provide CO2 monitoring units over the coming months. These monitors are expected to flag when CO2 levels rise to anything above 800 parts per million (ppm), though the recommended “action level” is higher at 1,400 - 1,500 ppm. The use of CO2 monitors is seen as a simple way of showing how well a space is ventilated. Lack of fresh air ventilation in buildings is associated with increased spread of Covid-19 and super-spreader events. The department has advised schools to check that its ventilation is adequate, and if it is not, it will offer support to install or upgrade equipment. “Schools that identify inadequate ventilation in a room can utilise their minor work grant (for minor improvements) or apply for emergency works grant assistance to address ventilation enhancements on a permanent basis,” it said. A spokesperson for the department told Passive House Plus that it was finalising a traffic light type system “with the expectation of having three or four settings from 800 ppm upwards”. The accompanying guidance advises schools to increase ventilation in a room if CO2 levels rise above 1,400 ppm. This is the “action level” also recommended by the UK’s Scientific Advisory Group on Epidemics (SAGE). The Irish education department also cites SAGE advice that “A consistent CO2 value < 800 ppm (absolute value) is likely to indicate that a space is well ventilated, but does not mean that an environment is risk free of COVID-19 risks”. The move by the Irish government follows advice earlier in the year from the country’s Expert Group on the Role of Ventilation in Reducing Transmission of Covid-19. The group’s report recommended that schools should receive clear advice on ventilation, and that CO2 monitoring equipment should be made available. John Wenger, professor of chemistry at University College Cork and chair of the expert group, welcomed the announcement. He told Passive House Plus in an email: “I am delighted that the Department of Education

CO2 monitors in the classroom Cath Jones teaches in a typical English rural primary school – a Victorian stone building with high ceilings, and high windows, but no mechanical ventilation. To help prevent the spread of Covid-19, her school took matters into its own hands and bought a CO2 monitor. “After a conversation with friends about Covid and airborne transmission last autumn, I broached the idea of using a CO2 monitor with a colleague. He was fascinated by the idea and did some research of his own. “The school discussed the idea and the finance officer was asked to look into it. They found a relatively cheap monitor – quite basic. And we put it in the classroom. We set a level based on our reading around – though this was really used just as an indicator, we knew the monitor would not be that accurate. The upper limit we set was very rarely reached, in fact. “The windows were always open a little, but the kids in class were very observant, and when levels rose they would say ‘Sir, sir it’s going up’, and the windows would be opened more widely . “If levels hit our limit we had a ‘purge’: everyone would go outside for five minutes with all doors and windows thrown open, and return when CO2 levels in the classroom had gone back down close to ambient. “The class teacher was very happy, as social distancing is very difficult for us. The classrooms in our school are small: we were supposed to be maintaining two metre distancing but we physically could not do it. There are generally four adults in the classroom (as extra support for pupils) so the teacher felt this was a valuable additional protection measure.” The children (aged around eight to ten) really liked it, and took ownership, Cath found. “If a different teacher came in – for example, I take that class on one afternoon a week — the kids would point rising levels out to the visitor: ‘Miss Jones, do you think we should open the windows?’ It gave them a bit of responsibility, to check the levels, they really took to it.” Achieving this level of ventilation came at the cost of thermal comfort. “We were all in thermals until the end of May. It was perishing.” But Cath and her colleagues are sanguine about this, especially in view of the fact that Covid transmission in her school has, so far, not been reported at all.


PA S S I V E H O U S E +

(DoE) in Ireland has responded positively to the recommendations contained in our reports. “The Group had a good level of engagement with the DoE, and are very pleased with the updated guidance on ventilation and especially the provision of CO2 monitors to schools.” He added that his personal advice is always to keep indoor CO2 levels below 800 ppm and to open more doors and windows to reach this level. But he added that it may not always be possible to achieve this, or achieve it comfortably, in a naturally ventilated building. The Teachers Union of Ireland also welcomed the move, but pointed out that the need for such measures had been clear to them and their members as early as the start of the academic year (September 2020). Summarising the results of a teacher survey, the union said last autumn: “Ventilation problems will now become critical as we move towards colder weather. Many schools, particularly those based in older buildings, will require new ventilation solutions and there will also be a need for monitors to signify when air exchange is required.” Hospitality Meanwhile, updated Covid guidance for the hospitality and leisure industries was also released in Ireland at the start of June by Fáilte Ireland, the national tourist board. As with the guidance for schools, businesses are advised what steps should be taken to increase ventilation. However, unlike in schools, and the hospitality sector in some other European nations (see ‘Scores on the doors’) Fáilte Ireland stopped short of recommending CO2 monitors. There is also considerable emphasis on cleaning regime. University College Dublin immunologist Dr Gerald Barry welcomed the new guidance. However, he told the Irish Times that he felt there was still insufficient emphasis on air movement, which he believes is “far more important in mitigation than Perspex screens or hand sanitiser”. UK guidance In the UK, the Delta variant of Covid was increasing faster in school age children than any other group at the time of writing, in mid-June. However, the government recently reversed its requirement for secondary school children in England to wear masks in school, and is not offering support either for CO2 monitors or for upgrading inadequate ventilation, despite numerous calls for it to do so. The UK’s Department for Education makes similar recommendations to those in Ireland on window opening and maximising fresh air flow though mechanical systems. However, although its advice refers to CIBSE guidance (which suggests CO2 levels be brought below 1,400 ppm), there is no specific suggestion that UK schools use

monitors to check ventilation effectiveness. Experts have been calling for school ventilation to be upgraded on a national basis, and for CO2 monitors to made available in UK schools. Professor Christina Pagel of University College London is one of many experts concerned about this inaction, especially in the light of what appears to be “significant transmission” of the Delta variant in UK schools. “We need to address this with mitigations in schools ASAP to stop disruption to education and wider spread,” she said on Twitter. Her view echoed an editorial on 1 June in the British Medical Journal by Dr Deepti Gurdasani, senior lecturer in epidemiology at Queen Mary University London, and colleagues. The editorial said that even at the time, it had been clear that removing the requirement for face coverings in secondary schools in England was ill advised “given the clear evidence for the role of children and schools in transmission of SARS-CoV-2 and the rise of the new variant”. The group added that as well as the re-instatement of masks, “there needs to be central investment in ventilation and air cleaning in schools, including CO2 monitors, and air filtration devices, to supplement ventilation where needed.” Passive House Plus asked if the UK government planned to follow the example of Ireland and offer support to schools to upgrade ventilation, and make CO2 monitors available, but the department did not respond specifically to this question. Some schools have independently purchased CO2 monitors [see ‘CO2 monitors in the classroom’], but their purchase and use is discretionary. Many UK schools are reportedly focusing resources on surface cleaning and hand sanitising instead. It is not clear exactly how much of the current spread of the Delta variant in the UK is occurring via school outbreaks, because detailed data is not currently being published by public health authorities in England. On 1 June, Citizens Advocacy Group and the data rights agency AWO took the first steps in a legal action against Public Health England, on the grounds that the agency was “acting unlawfully” in withholding data, and was “subject to political interference” in breach of its duty to protect public health.ii

i ' Mask Use and Ventilation Improvements to Reduce COVID-19 Incidence in Elementary Schools — Georgia, November 16–December 11, 2020', Centers for Disease Control and Prevention, 28 May 2021 ii 'Covid-19: Government faces legal challenge over alleged suppression of school data', British Medical Journal, 2021; 373 (1 June 2021) iii 'A paradigm shift to combat indoor respiratory infection', Science, 14 May 2021, Vol 372, Issue 6543, pp. 689-691

NEWS

‘Scores on the doors’– making CO2 monitors mandatory in public buildings Regulatory authorities around the world are being urged to follow the example of pioneering countries like Spain, Belgium and Canada, and require the display of live CO2 monitoring in buildings open to the public. In a joint letter in the journal Science, a distinguished international group of scientists say that visible, live displays of air quality should be a requirement for all premises open to the public. iii The 40-strong team, from disciplines including public health, infectious diseases, respiratory medicine, epidemiology and engineering, pointed out that there are strict controls on food, water and sanitation, in order to prevent mass outbreaks of dangerous infections. They warn that we are yet to take air quality as seriously, despite its obvious impact on the spread of deadly diseases such as Covid-19. “Wide use of monitors displaying the state of IAQ [indoor air quality] must be mandated. At present, members of the general public are not well aware of the importance of IAQ and have no means of knowing the condition of the indoor spaces that they occupy and share with others,” they write. “Visible displays will help keep building operators accountable for IAQ and will advance public awareness, leading to increased demand for a safe environment.” Regulation of air quality, and the requirement for publicly visible monitors, is now required in some countries. In Belgium, and a number of provinces in Spain, including the Balearic Isles and Asturias, businesses such as hospitality and indoor gyms are required to display a CO2 monitor, and to keep CO2 below a set level (in Asturias this is a challenging 800 parts per million). In North America, the focus is schools. For example, every classroom in Quebec will be provided with CO2 monitors to "ensure optimal indoor air quality". Meanwhile in New York, every room in every school has its ventilation assessed, and the results are displayed online.

ph+ | news | 25


MARC Ó RIAIN

COLUMN

The emergence of thermal bridging & thermal bypass In his latest column, Dr Marc Ó Riain takes a look back at the some of the first projects to address the phenomena of thermal bridging and thermal bypass in buildings.

A

s I prepared for a roundtable talk on thermal bridging hosted by Passive House Plus, it got me thinking about the origins of thermal bridging, so I did a little digging. Like so much research in low energy buildings, the discovery of thermal bridging would come from Scandinavia in the mid-1950s and be developed further in the northerly latitudes of Canada in the 1960s, whilst thermal bypass would be defined by the ‘Princeton House Doctors’ in their ground-breaking retrofits of the late 1970s in the leafy suburbs of New York State. Research indicates that a working knowledge of cold bridging was part of Scandinavian construction prior to the 1950s. However, linear and point thermal bridging

The post-war brutalist movement saw an increase in concrete constructions in Europe, the UK and Ireland, with thermal bridging between internal partitions and slabs, and external walls, causing issues in most standard industrialised constructions well into the 1970s, before insulation was widely used. In a retrofit context, the oil crisis of 1973/74 saw the introduction of weatherisation and insulation grants, and a general interest in energy conservation. A group of academics in Princeton in 1977 would become the pioneers of building energy retrofit, and would establish the basis for internal thermal bypass as distinct from thermal bridging.

Heat transfer was carried both convectively in the block cavity and conductively in the continuous block mass. is first reported by Danish engineers Egeskjold and Korsgaard (who would later design the first zero energy house in Copenhagen in 1974) when examining moisture transfer in building envelopes. They had identified the risk of condensation particularly with continuous concrete intermediate floor slabs, and advised on using an internal cork insulation below the slab, and timber board above, to mitigate risk of damage or discoloration. They also identified that modern tighter concrete constructions were aggravating the risk of condensation at cold bridges. In 1963 Brown and Wilson, writing in Canadian Building Digest, warned that linear thermal bridges could cause condensation and structural damage in freeze thaw conditions, which can be “readily overcome where insulation is placed over the entire exterior”. They highlighted the impact of lateral heat movement in a non-continuous construction, such as a timber frame detail commonly found in the US and Canada at the time. There seemed to be a standard construction detail placing cork on the interior of timber studs or structural members to increase surface temperatures, which resulted in lateral heat movement from structural members toward the intermediate construction materials.

26 | passivehouseplus.ie | issue 38

The Centre for Environmental Studies at Princeton University retrofitted recently built houses in nearby Twin Rivers with a focus on space heating, water heating and air conditioning. “House Doctor” inspections analysed air infiltration, heat loss to insulated attics and non-insulated basements, conductive heat loss through heating pipes, heating controls, setpoints, passive solar and appliance heat gains, and payback periods. They used infrared cameras, thermal modelling, wind tunnel smoke tests, and one time air pressurisation with tracer gas (sulphur hexafluoride) to establish the rate of air change, which was ground-breaking in 1977. What was critical about the study was its examination of the performance of the inner building links to the unheated attic and basements. The team had modelled the expected temperature of the cold attic spaces, but their on-site inspection found them to be a far higher temperature, resulting in 35 per cent overall heat loss in winter. They discovered that the cavity in the party walls between houses was creating a thermal bypass. What they were highlighting was not a conductive heat loss (thermal bridge) but a convective heat loss as warm air travelled behind the stud and bypassed the attic insulation.

The team went to great lengths to seal the attic from living area and party wall. They simulated the mean temperature reduction in the attic after sealing, but soon discovered a discrepancy in the actual temperature reduction. Having resolved the convective heat transfer the researchers were left scratching their heads and looking for a parallel thermal transfer route. Eventually they rounded on the 200 mm hollow cinder blocks in the party wall that linked basements to inhabited floors to the attic. They discovered that the additional heat transfer was carried both convectively in the block cavity and conductively in the continuous block mass: thermal bypass and thermal bridging. In the next issue we will move to another Canadian project. The Conservation House in Saskatchewan was built in 1977 and is really the first time we see passive type principles beginning to emerge and coalesce in one project. n

References Brown, W. and Wilson, A., 1963. Thermal bridges in buildings. Canadian Building Digest, 08. 1957. Work of the Rationalisation Committee for Building Assemblies. Copenhagen: The Institution of Danish Civil Engineers. Birkeland, O., 1979. Energy losses through thermal bridges. Batiment International, Building Research and Practice, 7(5), pp.284-284. Socolow, R., 1978. The Twin Rivers program on energy conservation in housing: highlights and conclusions. Energy and Buildings, 1(3), pp.207-242.

Dr Marc Ó Riain is a lecturer in the Department of Architecture at Munster Technological University (MTU). He has a PhD in zero energy retrofit and has delivered both residential and commercial NZEB retrofits In Ireland. He is a director of RUA Architects and has a passion for the environment both built and natural.


Leading the Way in

Sustainable Home Heating Global Warming is everyone’s business.

300mm in Attic = U-value 0.11 W/m2K

All our boilers are HVO Ready a fossil fuel free energy source that is fully biodegradable, clean, sustainable & non-toxic with superior operational performance. Offering an extremely cost-effective alternative to other low carbon heating technologies - and a gamechanger in helping Ireland achieve its net-zero carbon target.

225mm in Timber Frame wall = U-value 0.14 W/m2K

The warmest and safest natural fibre insulation, made in Ireland

Envirogreen & Silver Boiler Range

As Ecocel cellulose is pumped in it achieves a level of air-tightness not possible with any other sheet or roll out material.

The Most Efficient Boiler on the market • Fossil Fuel Free Ready • Up to 97.5% Efficiency • 25-30% Savings on Fuel Bills • Easy to Service & Maintain

Ecocel will last the life span of the building and make building safer in event of fire.

ERP Rating

A

Comprehensive Warranties On All Parts Free Design Consultation - Call or Email Today t: +353 (0)26 45253 | e: info@firebird.ie | www.firebird.ie

Ecocel Ecocel, due to its natural fibres creates a healthy indoor air quality and is Carbon Negative when installed.


TIMBER ENGINEERING

CASE STUDY

ENERGY BILLS

€25

PER MONTH FOR SPACE HEATING & COOLING (Estimated, see ‘In detail’ for more) Building: 223 m2 uncertified passive house Build method: Timber frame Location: Limerick, Ireland Standard: Uncertified passive house

28 | passivehouseplus.ie | issue 38


CASE STUDY

TIMBER ENGINEERING

AB OV E T H E C U RV E LIMERICK PASSIVE HOUSE SHOWCASES PRECISION TIMBER ENGINEERING

Sometimes it takes the constraints of a challenging site to bring out the best possible design, and that was certainly the case for this Limerick City passive house, where the project team managed to deliver a unique, curving passive house in response to a tricky urban plot. Words by John Cradden

ph+ | timber engineering case study | 29


TIMBER ENGINEERING

CASE STUDY

D

esigning a completely bespoke home on a tiny site in a very mature, built-up urban area is the kind of brief that many architects relish, not least the challenge of creating a distinctive form that functions brilliantly, while ensuring that it blends in aesthetically with neighbouring homes. Throw in the desire to build to the passive house standard, and you have quite the project. But spend a bit of time taking in the sight of this really interesting, three-bed, single-storey dwelling in Limerick city — particularly the way in which almost the whole house orients towards its curved courtyard — and you can very quickly see why architect Barbara Carr (of local practice Studiomove Architects) and her client, John , are so pleased with it. The new building has a bigger footprint than the original house that was demolished to make way for it, but it still blends in nicely. “The front of the house has very similar proportions to the bungalows that are there, and we didn’t want to do something that really jumped out,” Barbara says. “But inside it’s completely different. That’s why I called it the Tardis. When you come up, you can see that it’s different, but it really doesn’t shout out and I really loved that aspect of it. And then you come in the front door and there’s that sense of the sweep of the courtyard around the site that surprises you.” The Tardis certainly manages to maximise every one of the 220-odd square metres available to it, and while it butts up closely against neighbouring properties, being single storey means there is no risk of it overlooking adjacent homes. A driving force behind the project was John and his wife’s previous experience of living in an early 20th century red-brick home. Although they really loved the house, with its period features, it was registered with the local heritage council and they felt that any attempts to insulate it would be severely restricted. Even with a 30 kW condensing boiler and heating zones, the house struggled to keep them warm in winter. As an engineer, John had the idea of doing a self-build very firmly on his bucket list. He was in the fortunate position to be able to take some time off work to serve as the project manager and main contractor. When the opportunity arose to buy a house that came up for sale in the area, the couple decided to take the plunge, knocking down the original 1950s bungalow to create a clean slate for a new build. “Initially all I knew was I wanted to build a warm house. That was the starting point. So, I researched what could be done, what’s out there and it kind of led me on to the whole concept of the passive house standard,“ says John. “What I really liked about it, and this is from an engineering point of view... is that you could design and model the house up front and see how it would perform rather than coming up with a notional design and then hope it would work out.” He undertook the passive house designer training course run by MosArt Architects in Wicklow (which Barbara also did), and also decided to do a lot of the work himself, par-

The idea of wrapping the house around three sides of the site was adopted.

30 | passivehouseplus.ie | issue 38

Drone photos: Cathal Ryan / ARC Images


CASE STUDY

ticularly the mechanical and electrical, which allowed him to indulge in his enthusiasm for the latest in smart home automation technology from Loxone. While it’s clear from the performance figures that the Tardis works as a passive house, it was agreed early on that the design wouldn’t be a slave to the standard. “We didn’t want to wind up with a box, basically, with the windows on the south,” says John. So, while a warm, comfortable home was the main aim, achieving the standard – with or without certification — was a nice-to-have rather than a must-have. What made things tricky was the orientation. The original house faced south but straight onto a high, six metre high brick wall with an apartment block behind it. “We looked at it and thought ‘Oh, crikey’, Barbara says. “I mean, it’s a brilliant site in terms of its proximity to town and privacy, but the orientation then was really compromised by these things.” The idea of wrapping the house around three sides of the site was adopted so that the house orients towards the courtyard garden rather than the back wall. So, while it’s not far off the L-shape form that John had suggested, “it embraces the garden rather than addressing the wall,” says Barbara. “We calculated that we’d get enough south light into the courtyard of the house in summertime, but had to play around with window sizes as the curved courtyard crept around to face north. We also reduced the high-level north and east-facing windows in size.” Barbara says that because the form factor was not ideal for passive house — being single storey and spread out, there is a large surface area from which heat can escape — insulation and the orientation of windows was critical. A number of different build systems were investigated, including structural insulated panels, insulated concrete formwork (ICF) and blockwork, but it was decided that a twinwalled timber frame would give the best detailing and, more importantly, would lend itself to

TIMBER ENGINEERING

the non-rectilinear shape of the house. Indeed, there’s no doubting that the geometry added a layer of complexity to the build, particularly with regards to the roof. Although it’s a mono-pitch, there’s a lot going on with it. It sweeps around in a curve, getting wider to accommodate high level windows above the kitchen and bathroom. All this, along with the curved courtyard window setting, generated a fair bit of “swearing” among the build team in its bid to make it all come together. Given the prominence and importance of the view facing out into the courtyard, the choice of external doors and windows was an important one. John and Barbara chose an Austrian company called Josko and even visited the factory, where they fell in love with their internal Venetian doors, made of bog oak. “These add a real wow factor to the interior,” Barbara says. “They are extra high, flush-fitting, in great finishes and with a magnetic latch system. There was quite a bit of work getting them to fit correctly.” It wasn’t in the plan, but they also opted to line the underside of zinc roof overhang in the courtyard with timber battens. It was felt that the view from inside out into the courtyard would look quite flat and dark with just the zinc roof overhang, and undermine the look of the beautiful timber windows. So, a joiner and his experienced father were commissioned to add matching battens, which they set using the radius of the curve of the building. “It took time to get them looking right,” Barbara says. “But now it’s really beautiful. It’s warm and you can see it from inside. So, you’re looking at your timber windows from inside, and then you look up and you see these battens as well. It’s one of those things that wasn’t decided before. I think we all love it.” On the foundation side of things, John liked the idea of an insulated raft foundation but the need to build up tight against the back wall effectively ruled that out, not to mention the – admittedly quite small – risk that an oil spill from the next door neighbour’s oil tank would

Anti-clockwise from top the curved courtyard-facing rear façade comes together, including curved steel frame; timber frame; airtight layer; and timber battens.

Main photos: Eamonn O’Mahony / Studioworks Photography

ph+ | timber engineering case study | 31


DG Windows TIMBE R E N G I N E E R I N G & Doors C A S E S T U D YJosko Partner DG Windows & Doors Josko Partner DG Windows & |Doors Josko Partner www.josko.com www.josko.one www.josko.com | www.josko.one www.josko.com | www.josko.one

The Josko Smart Mix The The Josko Josko Smart Smart Mix Mix

WINDOWS & DOORS WINDOWS & DOORS WINDOWS & DOORS

A Mix That Always Wins. A Mix That Always Wins. The market leader in Germany and Austria for wood-aluminium windows is also an expert for frameless floor-to-ceiling A Mix That Always Wins. glazing withleader passive performance. The market in house Germany and Austria for wood-aluminium windows is also an expert for frameless floor-to-ceiling

glazing withleader passive performance. The market in house Germany and Austria for wood-aluminium windows is also an expert for frameless floor-to-ceiling Made-to-order and manufactured to the highest standards, Josko products allow for extra-ordinary architectural glazing with passive house performance. designs. The windows, terrace doors andhighest sliding standards, doors feature slimproducts frames and offer a variety of different materials and Made-to-order and manufactured to the Josko allow for extra-ordinary architectural surface finishes to choose from. designs. The windows, terrace doors andhighest sliding standards, doors feature slimproducts frames and offer a variety of different materials and Made-to-order and manufactured to the Josko allow for extra-ordinary architectural surface finishes to choose from. designs. The windows, terrace doors and sliding doors feature slim frames and offer a variety of different materials and Designed & made in Austria. surface finishes to choose from. Designed & made in Austria. To visit our showrooms and find out more contact: T: (+353) 071 985 3753 Designed & made in Austria. Darragh Timoney on +(353) E: darragh@dgwindows.com To visit our showrooms and086 find389 out 6500 more or contact: T: (+353) 071 985 3753 Greg Timoney on +(353) 087086 254389 4232 DG Windows, Blacklion, Co Cavan Darragh Timoney on +(353) 6500 or E: darragh@dgwindows.com To visit our showrooms and find out more contact: T: (+353) 071 985 3753 Greg Timoney on +(353) 087 254 4232 DG Windows, Blacklion, Co Cavan Darragh Timoney on +(353) 086 389 6500 or E: darragh@dgwindows.com 32 | passivehouseplus.ie | issue 38 Greg Timoney on +(353) 087 254 4232 DG Windows, Blacklion, Co Cavan


CASE STUDY

TIMBER ENGINEERING

damage the EPS of the insulated foundation. A standard raft foundation was installed instead. The use of timber frame, supplied by Galway firm Long Life Structures, adds bonus points for a low carbon material, as does the cellulose insulation in the walls and roof. “The roof was what attracted me to the project really,” says Emmet Nee of Long Life Structures. “I always love doing curved work, curved carpentry. We’ve gained a bit of a reputation for doing challenging houses like this. “We see ourselves more as thermal envelope specialists rather than just timber frame suppliers. The good thing with timber frame is that the design stage of the drawings will show up any areas that require deep thinking, and that’s where you work it out. For this house we had to work out each individual roof rafter instead of doing one and repeating it 60 times.” The twin wall system used on this project, with two cellulose-filled studs separated by another layer of cellulose, is the company’s standard build method for passive house projects, as it eliminates thermal bridging through the walls. The company also boasts an enviable record of achieving better than 0.6 air changes per hour on every house it has built to date. “Airtightness doesn’t happen by accident, it has to be designed in,” Emmet says. “When we go to site we have our airtightness strategy honed in. The real challenge is when you’re erecting the frame — those are there areas you won’t be able to get to again. This is the reason we erect our own frames rather than sub-contract it out.” John and his partner moved in a year ago, so they’ve experienced both a summer and a

ph+ | timber engineering case study | 33


TIMBER ENGINEERING

CASE STUDY

Bespoke homes built to outstanding quality and energy efficiency.

Timber frame structure. Airtightness below 0.6 ach. Natural insulations. Insulated foundations. Ventilated facades. Boardmark concrete Follow us on instagram to see our onsite projects in design and build stages.

LONG LIFE STRUCTURES

Timber Frame & Thermal Envelope Specialists.

34 | passivehouseplus.ie | issue 38

Achieving airtightness levels below passive standard, we are more than just your typical timber frame supplier.

Contact LONG LIFE STRUCTURES on 091 394190 info@llstructures.ie www.llstructures.ie


CASE STUDY

TIMBER ENGINEERING

The geometry added a layer of complexity to the build.

winter. “On the face of it, people think of passive houses as cheap to run and that’s it, but it’s actually a very, very comfortable house in terms of the constant temperature, with no drafts, and it’s a single zone temperature-wise throughout.” Since they had their smart meter installed by ESB networks, John has been tinkering around with the Nilan air-to-water heating and ventilation system to see how it works best in combination with the 3.5 kW solar PV panel array and a 4.8 kW battery. “Traditionally you might have your day and night meter, but now you’ll have maybe three or four different rates over the course of 24 hours and so we’re looking at how we can maximise that capability with a PV,” he says. As an engineer used to project-managing more complex industrial projects, John very much enjoyed managing this build on a personal level. “One of the things that I found with building this house is that there was emotion involved. If you’re doing an industrial project, you have a specification, you’re not worried about colours or worried about would the client be happy with this or that and so on.” “When people look at these Grand Design programmes and so on, they have no idea what’s going to happen in the background in terms of the complexity involved in it. The best thing I ever did was to do the passive designer course, to bring myself up to speed, you know, from selecting windows, to detailing, to minimising thermal bridges and so on. I’ve learned so much from it, it’s absolutely unreal.” No doubt he enjoyed installing the state-ofthe-art smart home system that controls everything from lighting to blinds to heating. “He had great fun with that,” Barbara says. Personal joys aside, John is also clear on what the project has achieved and is actively considering applying for passive house certification. “We pushed the envelope in terms of getting as close as you can to the passive standard without sacrificing aesthetics in an urban, built-up area.”

ph+ | timber engineering case study | 35


TIMBER ENGINEERING

CASE STUDY

Changing the shape of buildings throughout Ireland

CEMENT BOARD RENDER SYSTEM Aquapanel Cement Board technology sets new standards for the design and construction of buildings in Ireland and is a proven alternative to block and brick for exterior applications for both timber and steel frame construction. Greenspan can provide a complete design specification and build option for your building façade. Proven track in Ireland for over 20 years.

IAB certified, Homebond and DOE approved. Walls finished with Aquapanel deliver an estimated 75% reduction in embodied CO compared to cavity wall construction.

2

Tel: 069 82222 Email: sales@greenspan.ie 36 | passivehouseplus.ie | issue 38

www.greenspan.ie


CASE STUDY

TIMBER ENGINEERING

CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

1 & 2 Installation of the curved courtyard windows, triple glazed aluclad units from Josko; 3 timber cladding was fitted to the underside of the zinc roof overhang in the courtyard for aesthetic reasons; 4 Intello vapour control membrane and airtightness taping to ceiling; 5 the Nilan Compact P combines heat recovery ventilation along with air heating and cooling; 6 solar battery and Solis Hybrid inverter.

SELECTED PROJECT DETAILS Architect: Studiomove Architects Civil & structural engineering: Mike Boyce Consulting M&E design: GEON Timber frame & raft foundation: Long Life Structures Quantity surveyor: Steadfast Mechanical contractor: Paul Corcoran Plumbing & Heating Electrical contractor: Deegan Contracts Limited Airtightness test: Hession Energy Cellulose insulation: Darmstadt, via Clíoma House Wufi analysis: Ecological Building Systems Airtightness products: Clíoma House Windows & doors: Josko, via DG Windows & Doors Space heating & ventilation: Nilan Ireland Roof windows: Fakro Blinds: Shade Tec Cladding: Aquapanel, via Greenspan Roofing: A & A Quinn Roofing Polished concrete floor: Mapei, via Topcoat Systems Landscape design: Manila Landscape Design Home automation (Luxone): GEON Lighting design: Wink

WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on passivehouseplus.ie & passivehouseplus.co.uk

EMBODIED CARBON

W

ith a cradle to grave score of 483 kg CO2e/m2 GIA, this project beat the RIBA 2030 Climate Challenge target of 625 kg CO2e/m2 GIA, according to calculations by John Butler Sustainable Building Consultancy using PHribbon. While the revised RIBA methodology is aligned with LETI’s embodied carbon targets, it differs in a crucial regard: LETI excludes embodied carbon emissions from PV arrays, considering them as part of the electricity grid, effectively. Excluding the large PV array in this case would cause the figures to drop by a further 37 kg CO2/m2. The calculations included a number of assumptions where necessary, in particular in the area of mechanical, electrical and plumbing services, where environmental product declarations (EPDs) remain rare. Data from a French Product Environmental Passport for the heat pump which most closely resembled the compact unit installed was used, and data for stainless steel ductwork was used in the absence of polypropylene ductwork data. The analysis included interior and exterior finishes, sanitaryware and sinks, but not all fitted furniture, fixings and equipment. Default or comparable data was used in a number of other areas. Transport emissions were adjusted to provide rough approximations for given product types. No replacements were assumed for the fabric, and two replacements of the heat pump were assumed – albeit with inert refrigerants assumed – within the 60 year projected lifespan in the calculations. A comparison between the as built external wall system and a notional cavity wall build up to the same specifications –

with transport and construction emissions adjusted accordingly for those elements specifically – showed cradle to practical completion figures of 58 kg CO2e/m2 for the as built walls (including 30 kg CO2e/m2 for materials) versus 114 kg CO2e/m2 for the cavity wall comparison (including 93 kg CO2e/m2 for materials). The complete building as built was compared to the same complete building built with cavity wall construction and with no GGBS substitution in the foundations. The cradle-to-grave figures increased from 483 to 563 kg CO2e/m2, while the as-built spec also included 150 kg CO2e of sequestered CO2 in the timber and timber-based products, whereas the alternative with cavity walls was estimated to include 83 kg of sequestered CO2e (both versions assumed the same timber and timber-based products used for internal walls and roof build up). As ever, it is worth remembering that the module C emissions relate to the end of life at the building. The majority of the module C emissions relate to sequestered CO2 in the timber and timber-based products, and it is assumed that these emissions are released at the building’s end of life – with 75 per cent of timber assumed to be incinerated, and 25 per cent landfilled. Even if the timber was instead assumed to be recycled or reused, the sequestered emissions would move outside of the boundary conditions of the building life cycle assessment, and pass on to the next use. While this may give the appearance that a significant amount of CO2 is released into the atmosphere at the building’s end of life, it is possible that timber may remain sequestered in buildings for hundreds of years.

ph+ | timber engineering case study | 37


TIMBER ENGINEERING

CASE STUDY

S

Studiomove architects

Architects in Limerick city

OUTSTANDING INDOOR CLIMATE

www.studiomove.ie hello@studiomove.ie

Tailor the ideal ventilation and climate solution and get total control of the indoor climate in the dwelling directly from the mobile phone. Nilan’s Compact P solution is certified to the highest Passive House standards including nZEB/Part L. • Passive House (nZEB/Part L certified) • Extract air • Supply air • Humidity control • Domestic Hot Water • Heating • Cookerhood control • All in one technical room

www.nilanireland.ie • info@nilan.ie • Tel +353(0)66 7169587

Outstanding Indoor Climate 93mm x 135mm.indd 1

09-03-2021 11:23:41

Contemporary Vernacular Passive House, Co. Cavan Architect: Niall Smith Architects Air Pressure Test Result: 0.39 AC/H @ 50 Pascals Specific Heating Demand: 11 kWh/m2/year U Value for Walls: 0.11W/m2

Achieve your vision ...with our support Discover our solutions online at

ecologicalbuildingsystems.com 38 | passivehouseplus.ie | issue 38

Ecological brands used: Gutex, Pro Clima, Bosig, Wellhöfer, Auro, Thermafleece


CASE STUDY

TIMBER ENGINEERING

IN DETAIL Building type: Detached 223 m2 timber frame house. Location: Limerick City

or €25 per month inclusive of VAT, but excluding standing charge and PSO levy. These figures are based on final energy demand (delivered energy) figures from the PER sheet of PHPP.

Completion date: February 2020

timber I-beam rafter (at various centres due to radius of roof) filled with Darmstadt Thermofloc cellulose insulation, Intello Plus vapour control membrane, 50 x 50 mm battens at 400 mm c/c to form service cavity, 12.5 mm Gypsum plasterboard and skim. U-value: 0.116 W/m2K

Airtightness: 0.5 ACH at 50 Pascals Budget: Not disclosed Passive house certification: Uncertified Space heating demand: 18.44 kWh/m2/yr (PHPP) Heat load: 9.73 W/m2 (PHPP) Primary energy non-renewable: 65 kWh/m2/yr Heat loss form factor: 4.0 Overheating: 10% (PHPP) Number of occupants: 3 Energy performance coefficient (EPC): Pending Carbon performance coefficient (CPC): Pending BER: Not yet completed Environmental assessment method: N/A Measured energy consumption & energy bills: During 2020, the household electricity bill averaged €80 per month, for all space heating, hot water & electricity. However, John installed a solar PV array in September 2020, and a smart meter with varied electricity rates in April 2021. This already appears to be making a big difference in electricity consumption. For example, while the house consumed 1,645 kWh in May 2020, its projected energy consumption for May 2021 was just 370 kWh (as of May 25). For space heating & cooling only, taking the current Energia day rate (0.1565c), this property would have an estimated bill for space heating and cooling of €300 annually

Thermal bridging: Walls, pitched and flat roofs all in timber frame with cellulose insulation meant that the line of insulation was continuous from one plane to another. A twin wall timber frame system, 330 mm thick overall, helped to reduce thermal bridging. Psi values were taken as default 0.08 W/ mK, apart from the curved courtyard wall. The detail around a steel beam above the large window/door wall to the courtyard had a calculated psi value of 0.04 W/mK. Foundation/wall psi value was 0.01 W/mK. Ground floor: 150 mm thick reinforced concrete slab (grade C30/37) followed above by 280 mm Mannok Therm Floor PIR insulation, with ducting pipework for Nilan ventilation cut in, 75 mm screed containing pipework for underfloor heating. 12 mm grey Mapei Ultratop Terrazzo & Irish beech pebble polished concrete finish. U-value: 0.078 W/m2K Walls: 20 mm Aquapanel exterior cement board, followed inside by 50 x 50 mm timber battens to create ventilated cavity, 22 mm timber sheeting and pro clima Solitex Humida Fronta Quattro wind-tight membrane, 89 x 38 mm outer leaf non-loadbearing stud at 600 c/c filled with Darmstadt Thermofloc cellulose insulation (0.037 W/mK), 100 mm layer of cellulose between inner and outer timber frame, 140 x 38 mm inner load bearing stud at 600 c/c filled with cellulose insulation, 12 mm Durelis Naturespan Vaporblock racking airtightness layer, 50 x 50 mm battens at 400 mm c/c to form service cavity, 12.5 mm Gypsum plasterboard and skim. U-value: 0.120 W/m2K Roof: Zinc cladding with standing seams, followed inside by Alutrix vapour barrier, 18 mm penny gap boarding, 50 x 50 mm timber battens, 18 mm OSB sheeting, 300 mm deep

Roof, flat: Fatra PVC membrane, followed beneath by 120 mm TR 26 PIR insulation board, vapour barrier, 18 mm plywood sheeting, timber firring pieces falling from 92 to 50 mm (1 in 80 fall), joists 170 x 44 mm with full fill cellulose insulation, Intello Plus vapour control membrane, 100 x 38 mm battens at 400 mm c/c to form service cavity, 15 mm gypsum plasterboard and skim. U-value: 0.105 W/m2K Windows: Josko Platin Plus triple glazed aluclad timber windows. U-value: 0.82 W/m2K average for the project. Roof windows: 2 x Fakro U8 triple glazed roof windows. U-value: 0.8 W/m2K Heating system & Ventilation: Nilan Compact P XL (430 m3/hr) unit which combines heat recovery ventilation along with air heating and summer air cooling through the balanced ventilation ductwork. Passive House Institute certified. Effective heat recovery efficiency: 80% (PHi), calculated with PHPP, considering stated efficiency and installation. The Compact P is backed up with a Nilan air-to-water heat pump (Air9) which provides weather compensated hot water to zoned underfloor heating circuits. Seasonal coefficient of performance for Compact P and Air9 (variable speed compressor output power) Ecodesign A+++ SCOP 511% efficiency. Water: N/A Electricity: 19 m2 Trina Mono solar photovoltaic array with 3.48 kWh installed capacity. Battery storage 4.8 kWh. Solis Hybrid inverter. Green materials: Cellulose insulation, timber frame.

ph+ | timber engineering case study | 39


WEST IRELAND

CASE STUDY

ENERGY BILLS

€17

PER MONTH FOR SPACE HEATING ONLY (Estimated, see ‘In detail’ for more)

Building: 206 m2 deep retrofit & extension to detached dwelling Method: External insulation & timber frame extension Location: Ballisodare, Co Sligo Standard: Fabric first retrofit Energy rating: A3

40 | passivehouseplus.ie | issue 38


CASE STUDY

WEST IRELAND

BUTTERFLY

EFFECT SLIGO DEEP RETROFIT DELIVERS WARMTH, LIGHT AND SWEEPING MOUNTAIN VIEWS

Complete with butterfly roofed extension, this fabricfirst renovation has turned a cold and uninspiring 1970s bungalow into a cosy A-rated modern home, with some clever design touches helping to open the house up to wide-angle views and dramatic coastal light. Words by John Hearne

ph+ | west ireland case study | 41


WEST IRELAND

CASE STUDY

D

erek Sherlock bought the bungalow which would eventually become his and his wife’s new home back in 2014 and rented it out while researching how he might renovate it. At the time, he says, it was probably the coldest house he was ever in. “Drafts? Lot of drafts coming up through floorboards. It had an uninsulated suspended timber floor. We rented it to a builder’s son, and he went around the skirting board with some sort of a tape to try to cut down on the drafts. They had a double layer of curtains in the TV room just to try to keep the heat in. It was one cold bungalow.” Their family reared, Derek and his wife had decided to downsize, and return to his homeplace in Ballisodare, County Sligo. The house they bought was your typical 1970s bungalow: long and dark, with an uninspiring layout, and, as he was quick to find out, an even more uninspiring thermal profile. There had been attempts to upgrade the insulation and the windows over the years, as well as an ill-advised attic conversion that fell far short of acceptable space and height standards. The house really had only one good feature: there are stunning views of Knocknarea and Benbulbin to the north and the Ox Mountains to the south. Taking advantage of those views would be a key element of the renovation. So too would comfort.

42 | passivehouseplus.ie | issue 38

“I wanted it to be good for the environment, but I also wanted it to be really comfortable for myself and my wife,” says Sherlock. “The money thing wasn’t a big motivator, though it’s actually cheaper to run than I thought it would be.” More about that later. Light was another key requirement, as was a more modern layout and additional downstairs space. In the two years prior to the start of the project, Derek and his wife did the rounds of building expos in Dublin and Belfast, talked to a lot of experts, and explored the full range of options that were open to them. “I looked at windows – would we do double or triple glazing? External wall insulation? Would we dryline it? Pump the walls? Were we going to do underfloor heating or rads? We looked at solar panels, heat pumps, oil or gas. Everything.” Derek also read Passive House Plus eagerly during this time to glean ideas for the project, and to learn about low energy building. He bought himself a maths copy, in which he sketched out the existing layout of the house, then began experimenting with different layouts and extensions, looking for ways to introduce light and create better room configurations. He also engaged James Walsh of Low Energy Design to assist with this element of the project. Walsh is a passive house architect with exten-

I wanted it to be good for the environment, but I also wanted it to be really comfortable.


CASE STUDY

The butterfly roof allowed us to bring in morning light.

Photos: Kelvin Gillmor

sive experience. His work on St. Bricin’s Park, a Dublin City Council passive refurbishment project in Arbour Hill, was profiled in issue 30 of Passive House Plus. Working together, they created a design which sought to make the most of the spectacular views, ensure a light-filled living space and deliver the levels of thermal comfort that had been so absent in the original design. “We designed an open plan for the kitchen, dining and living area,” Walsh explains. “It’s L-shaped so that you can see Knocknarea out through the corner window. We also built a butterfly roof because the house is north-facing at the back, which is the elevation where you get those spectacular views. The butterfly roof allowed us to bring in morning light through high level windows on the east, and evening light though high level windows on the west.” He points out that a standard A-type roof would have made it difficult to get sufficient light into the space, and that the butterfly roof had the added advantage of creating a more interesting profile. In the same vein, Sherlock wanted something more than a simple rectangular extension out the back. “I wanted to make it a bit interesting from the road. That’s why we put on the red cedar cube. We could have gone straight out into the back garden and put nothing on the gable, but that would have left us with one big rectangle. Instead, we went a certain distance out into the garden, then added that cube. My vision was that that was going to be our sitting area in the evening. I just didn’t want to be sitting in a corner of a big square box. I wanted to put a bit of a twist on it.” With so little to be salvaged from the original house, the build team removed the roof and broke the structure back to the walls. The existing raised timber floor was also removed, allowing the installation of a new, well-insulated floor, together with an underfloor heating system. When contractor Dermot Dunne exam-

WEST IRELAND

ined the walls, he discovered that they were not entirely insulation free. At some point in the building’s history, someone had pumped in insulation. Unfortunately however, it turned out to be some form of formaldehyde. “I couldn’t put a definite date on it,” says Walsh. “I’d read reports of issues to do with toxicity and off-gassing with this type of insulation. This probably would not be an issue because it had very likely been in place for more than five years. The other problem however was that it had shrunk in places, and I didn’t want to run the risk of leaving voids in the cavity. We got a specialist company in to suction it out, we cleaned it and then got it re-pumped.” In order to bring wall U-values up to spec, and to help eliminate cold bridges, external wall insulation was also added. Contractor Dermot Dunne had not installed external insulation before, but he registered with the SEAI as an installer and took guidance from the supplier before installing 150 mm of Baumit Graphite EPS. Thermal bridging is often a headache in retrofits. Here, in addition to the external insulation, the build team deployed thermal blocks at key junctions in new external walls, ensured insulation ran below the level of the perimeter path outside the house, designed the eaves for thermal continuity, and ensured the windows sat within the insulation zone. Sherlock was also keen to have underfloor heating throughout the house, so the engineer specified a very dense grade of timber for the flooring (dense timber conducts heat better) and installed a screed in the first floor too. Installing ventilation ducting in restricted spaces was another challenge on the build, as of course was airtightness. In meeting all these challenges, James Walsh talks about the crucial importance of getting sequencing right at the planning stages in order to ensure that insulation and airtightness measures are not adversely impacted after they have been fitted.

ph+ | west ireland case study | 43


WEST IRELAND

CASE STUDY

CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

7

8

9

10

11

12

1 The existing 1970s bungalow prior to retrofitting; 2 the house suffered from mould problems; and 3 had urea-based insulation in the cavity; 4 the old roof removed and the house stripped back to the structure; 5 installation of new triple glazed windows; 6 gap left under the eaves for external wall insulation, which would meet the roof insulation; 7 & 8 Mannok thermal blocks, which are lighter in colour, were deployed at key junctions to prevent thermal bridging; 9 construction of the new roof underway; 10 SIGA Majpell airtightness membrane and taping; 11 SIGA Majcoat wind-tight breathable membrane to the roof; 12 underfloor heating was installed on both floors.

44 | passivehouseplus.ie | issue 38


CASE STUDY

“It wasn’t the case on this house, but I’ve done a number of jobs where, for example, you’re putting insulation in the ceiling, and afterwards, the plumber realises that an additional pipe has to go in. They might lift the insulation and then fail to put it back properly. Those kinds of things do happen,” he says. Getting everyone on site conversant with insulation and airtightness targets is another great way of ensuring that no one does anything to compromise them. On the aforementioned St Bricin’s passive retrofit scheme, Walsh says the success of that project owed a lot to the fact that onsite training was provided for all of the tradespeople involved.

On this project, it is interesting to note that the best views and the extensive glazing lie to the north of the house. “Before we started,” says Derek Sherlock, “I used to think, ‘God, if those views were on the other side of the house, we’d have all of this lovely sun in the living room’ but I realise now that we just couldn’t have lived with that... the glare would have meant that you would have had to have blinds on the windows and would have had no comfort sitting there.” He also thinks that unimpeded glazing on the south elevation would have caused overheating. James Walsh says that there was no major thermal loss a result of having these glazed sec-

WEST IRELAND

They had a double layer of curtains just to keep the heat in.

ph+ | west ireland case study | 45


WEST IRELAND

CASE STUDY

BUILD WITH CONSCIENCE, IT’S MANNOK MADE CAVITY WALLS ELEVATED Achieve superior comfort and energy efficiency by building the inner leaf of cavity walls with Mannok Aircrete Thermal Blocks, Ireland’s best block for combined thermal, structural and fire performance. Get in touch to find out more: mannokbuild.com | info@mannokbuild.com | 08000 322 122 TAILOR MADE PACKAGES AVAILABLE FOR SELF-BUILDERS. VISIT SELFBUILDWITHMANNOK.COM FOR DETAILS. 46 | passivehouseplus.ie | issue 38


CASE STUDY

WEST IRELAND

tions to the north. “The north facing glazing was a deliberate design decision,” he says, “to take advantage of the magnificent views and slightly elevated site. As Derek was amenable to using triple glazed windows and doors with U-values of 0.8 generally, I knew that they would contribute to the thermal performance. That was reflected in the overall DEAP assessment and building energy rating. The wall U-values are predominantly 0.15 with some small sections at 0.13 and 0.17.” The house also gets quite close to Ireland’s nearly zero energy building standard (NZEB) for new build, beating the NZEB carbon performance coefficient target of 0.35 but narrowly missing out on the energy performance coefficient target of 0.3 (the house scored 0.34). When it comes to costs, Sherlock confirms that he has been pleasantly surprised. “From June 2017, when we moved in, to June 2018, the total cost of all electricity – not just the heat pump – came to €1,120. Then from June 2018 to June 2019, it went up by €40 to €1,160. And the following year, it was up a little further, to €1,200.” He notes too that he “never touches” the Ecodan air-to-water heat pump. The thermostat has remained set to 21 C since he and his wife moved in. The increase in bills over the last two year he attributes to rising energy prices as opposed to increased energy use. “It’s fabulous,” he says, “just fabulous. We love it here.”

SELECTED PROJECT DETAILS Client: Derek Sherlock Architect: Low Energy Design Main contractor: Dunwall Construction Civil & structural engineer: David O’Hara BER assessor: Energy Rating (Sean Clancy) Mechanical contractor: Tommy Finn Electrical & Plumbing Electrical contractor: Paul Morahan Electrical Services Airtightness tester: Ecoscan External wall insulation: Baumit, via Chadwicks Cavity wall insulation: Abbey Insulation Thermal blocks: Mannok Roof insulation: Isover Additional roof insulation: Mannok Airtightness products: SIGA Windows & doors: Munster Joinery Roof windows: Velux Roofing: Tegral Heat pump: Mitsubishi Ecodan, via Tommy Finn Electrical & Plumbing MVHR: Beam Vacuum & Ventilation MVHR installation: Paul Morahan Electrical Services

WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on passivehouseplus.ie & passivehouseplus.co.uk

ph+ | west ireland case study | 47


WEST IRELAND

CASE STUDY

Want to see your ad in the next issue of the magazine? To enquire about advertising, contact Jeff Colley on +353 (0)1 210 7513 or email jeff@passivehouseplus.ie

www.passivehouseplus.ie

48 | passivehouseplus.ie | issue 38


CASE STUDY

WEST IRELAND

IN DETAIL Building type: Deep retrofit & extension of detached 148 m2 1970s bungalow into 206 m2 dwelling. Location: Abbeytown, Ballisodare, Co Sligo Budget: Private Completion date: June 2017 BER Before: G (539 kWh/m2/yr) After: A3 BER (51.6 kWh/m2/yr) Energy performance coefficient (EPC): 0.336 Carbon performance coefficient (CPC): 0.317 Space heating demand (primary energy, DEAP): 11 kWh/m2/yr Energy bills: The client reports an average annual electricity bill (covering all energy use in the house) of €1,150, or €95 per month. The DEAP assessment of the house projected a delivered energy demand for space heating of 1,085 kWh/yr or 5 kWh/m2/yr. According to the cheapest available tariff available from Bonkers.ie, this would cost €203 including VAT at 13.5 per cent, or approximately €17 per month. This does not include standing charges or the PSO levy. Number of occupants: 2

insulation, new radon membrane and sump. U-value: 0.12 W/m2K Walls Before: Concrete block cavity walls with blown 60 mm cavity (insulated with formaldehyde). U-value: 1.78 W/m2K After: Silicone render finish externally on 150 mm Baumit Graphite EPS (0.031 W/mK) external wall insulation, on existing external cavity block leaf, removed formaldehyde insulation from cavity and cleaned cavities, pumped cavity with 60 mm platinum bead insulation, inner blockwork and internal plaster. U-value: 0.15 W/m2K Roof Before: Roof slates to sloped areas, room in roof with mineral wool insulation between rafters and studs. Pitch roof ceiling areas with 100 mm mineral wool insulation on the flat between roof joists. Plasterboard ceiling internally. U-value: 2.3 W/m2K After: Tegral fibre cement slates externally on 50 x 35 battens/counter battens, followed underneath by SIGA Majcoat wind-tight breathable membrane, 225 mm timber I-joists fully filled with Isover Metac insulation (0.034 W/mK), SIGA Majpell airtight & vapour control membrane, 75 mm insulated service zone with Isover Metac, 12.5 mm plasterboard ceiling. U-value: 0.16 W/m2K

Mannok Therm MFR-FFR PIR (0.022 W/mK), on 150 x 44 C16 roof timbers at 400 centres fixed to structural steel in accordance with engineer’s specification, on SIGA Majpell airtightness membrane, 75 x 50 battens at 600 centres for service zone and 12.5 mm plasterboard with skim finish internally. U-value: 0.16 W/m2K Side Extension roof: Single ply membrane followed underneath by 140 mm Mannok Therm MFR-FFR PIR (0.022 W/mK), on 150 x 44 C16 roof timbers at 400 centres fixed to structural steel in accordance with engineer’s specification, on SIGA Majpell airtightness membrane, on 75 x 50 battens at 600 centres for service zone and 12.5 mm plasterboard with skim finish internally. U-value: 0.15 W/m2K Windows & doors Before: Single glazed and some double glazed, timber / pvc windows and doors. U-values range: 2.4 - 4.8 W/m2K After: Munster Joinery triple glazed, argon filled, Passiv uPVC windows and doors: Overall average U-value of 0.80 W/m2K. Roof windows: Velux triple glazed roof windows. Overall U-value: 1.0 W/m2K Heating system Before: 20 year old oil boiler & radiators throughout entire building, with peat open fires.

Measured energy consumption: N/A Heat loss form factor: 2.7 Airtightness (at 50 Pascals): 1.94 air changes per hour (1.88 m3/hr/m2) Ground floor Before: Uninsulated suspended timber floor. U-value: 0.65 W/m2K After (upgraded): new concrete floor with 150 mm Mannok Therm Floor insulation (thermal conductivity 0.022 W/mK), 75 mm screed with underfloor heating & 40 mm perimeter

Extension walls 1: Silicone render finish with 250 mm Graphite EPS (Conductivity 0.031 W/ mK), on 215 mm blockwork with internal plaster: U-value: 0.13 W/m2K Extension walls 2: Cedar timber cladding externally on treated battens, on breather membrane over 350 mm cavity block wall with 150 mm blown bead insulation (0.031 W/mK) to cavity, internal plaster finish. U-value: 0.17 W/m2K Extension butterfly roof: Single ply membrane externally, followed underneath by 140 mm

After: Mitsubishi EcoDan Monobloc air-to-water heat pump serving underfloor heating (on both floors) and towel rails. 508 per cent efficiency for space heating and 226 per cent efficiency for water heating. Ventilation Before: No ventilation system. Reliant on infiltration, chimney and opening of windows for air changes. After: Beam Axco C90 mechanical ventilation heat recovery ventilation system — heat recovery efficiency of 85 per cent.

ph+ | west ireland case study | 49


D U N D E E PA S S I V E H O U S E

CASE STUDY

ENERGY BILLS

£106

PER MONTH FOR ALL HEATING, HOT WATER AND ELECTRICITY Building: 181 m2 detached dwelling Build method: Timber frame Location: Dundee, Scotland Standard: Uncertified passive house

50 | passivehouseplus.ie | issue 38


CASE STUDY

D U N D E E PA S S I V E H O U S E

P I TC H PERFECT BEGUILING DUNDEE PASSIVE HOUSE PUTS WOOD INTO WOODLAND

An intriguing new passive house in Dundee takes the traditional ‘box’ form associated with the standard and turns it on its head, using a series of pitched roofs and different claddings to make it feel more like a traditional city terrace than a single dwelling – built with a heavy emphasis on carbon sequestering materials. Words by David W Smith

F

enton House lies in a little oasis of beautiful old woodland in suburban Dundee. It is around 10 minutes by bike from the city centre, in the former grounds of Invergowrie House, a turreted fort built between the fourteenth and sixteenth centuries. From the second storey of this upside-down passive house there are wonderful views over the top of the wood and the surrounding cityscape, to the ever-changing light of the Tay Estuary. For owners David and Jenny Arrenberg, the warmth and comfort of Fenton House makes a welcome contrast with the freezing cold flat they previously occupied in Invergowrie House. “Living in Fenton House is ‘pinch yourself’ time,” says David, who works as an engineer for Scottish Water. “Before we started to build, I used to climb the trees to make sure we’d be able to see into the distance from the top floor. We can! The views of the river are gorgeous. There are lots of tidal changes and

you get sand banks one minute and it’s choppy the next. We can see as far as Kinnoull Hill in Perth.” As for the warmth, David spent a lot of the winter Covid-19 lockdown working from home in shorts and a T-shirt. “Our north-facing flat in Invergowrie House was the exact opposite. It was a converted storage room on the ground floor and slightly underground. There were zero passive house principles involved and it was freezing in winter. The difference with Fenton House is about 20 degrees!” The joy, however, is tinged with sadness. David’s father was a major inspiration for the project, but he passed away before it broke ground. “Dad was a man of many trades, an officer in the navy, a tree surgeon, and a picture framer, but he went on to become a plumber and builder. His talent as a tradesman was painting and stenciling — he was a very creative chap,” David says.

His father had always encouraged David to convert the plot of land — gifted by his aunt — into a permanent home. “To say I am disappointed he didn’t get to see the house is an understatement. I think about it daily. My dad always wanted to build his own house, but never had the money. He used to go on at me about building on the plot. And we worked on the woodland together with my brother from when I was nine years old. I kept finding reminders of him around the land, old bottles, tools and materials. His memory drove me on to do a good job when the work was hard,” he said. David is not native to Dundee, or Scotland. He was born in Bromley North, in London, and moved up with his English parents in 1987 when he was three and his brother was eight. He soon adopted the local accent, whereas his older brother has retained a London twang. The family lived in Invergowrie House, which

ph+ | dundee passive house case study | 51


D U N D E E PA S S I V E H O U S E

CASE STUDY

Living in Fenton House is ‘pinch yourself’ time.

52 | passivehouseplus.ie | issue 38

was split into four flats with the attached land divided between the owners. His aunt and uncle occupied the most spacious flat and had the largest, seven-acre plot. In 2003, after the death of her husband, his aunt went to live in Herefordshire. But she kept hold of about three acres of the land, with its magnificent 250-year-old cedars and oaks. Given David wanted to live in Dundee, and his keen interest in building a home, his aunt decided to offer him the land and the opportunity to build here. In 2015, David and his wife Jenny moved into the ground-floor flat at Invergowrie House. In the same year, they hired Kirsty Maguire, a Dundee architect specialising in the passive house standard, to design their home. They already had some clear ideas. They wanted an open-plan living space upstairs to take advantage of the views. The couple also wanted a low energy house. David’s civil engineering background meant he was knowledgeable about sustainable design. “The open plan could have made it feel a bit cavernous, lacking in character and over-reliant on the great views. But I designed a series of four pitched roofs,” said Kirsty. “The dining space, living room and kitchen are each defined volumetrically by the vaulting of the roofs. It gives them the feel of semi-separate rooms. Basically, we kept to a simple rectangular box — which was great for achieving passive house and cost management — but invested in a more complicated roof.” Each of the apexes has a glulam beam and an airtight layer that goes over the top of it. “You have to make sure the airtightness membrane is in place as you build, as it exposes the

glulam beams. They are very beautiful and part of the expression of the space. But it needs to be carefully thought out and installed,” said Kirsty. She specified low carbon materials, including wood-fibre insulation and a timber structure. The insulation came from Steico, and Kirsty said that she specifically chose wood-fibre due to its decrement factor — the time it takes for a peak daily temperature outside to become a peak daily temperature inside. Wood-fibre is better at controlling this decrement factor than lighter synthetic insulations, thus helping to prevent overheating. For the cladding, Kirsty chose Scottish larch and recyclable long-lasting zinc. Meanwhile, an air source heat pump was installed to provide constant hot water. The house was also equipped with an MVHR system, photovoltaic panels, and electric infra-red panels for space heating. Although the plans were submitted in 2015, getting approval was a slow process. The exact location of the house had to be moved a little after neighbours on the adjacent housing estates expressed concern that it would overlook their properties. David also had to put in place a woodland maintenance plan to ensure the protection of the mature trees. Another issue was fire engine access, which the council deemed essential. Meanwhile, David and Jenny were not even ready to begin immediately. They were busy scraping together all the money they needed to pay for the project. The total cost ended up at around £330,000, including Kirsty’s fee. Work eventually began in May 2018 and took a year to complete. The contractor, Craigs


CASE STUDY

Eco Construction from Linlithgow, had experience building passive houses and offered a flexible way of working that left David free to find cheaper prices for much of the work. “I hired plasterers, electricians and plumbers directly and Craigs Eco were happy to work with them. It saved quite a lot of money,” he said. Even greater sums were saved by David’s relentless bargaining over materials. “I was pretty ruthless when it came to bartering down prices. The zinc looks tremendous, but the original quote was for £95,000. I ended up getting it down to £54,000. My Excel spreadsheet never left my side and I reckon I saved over £60,000 arguing over quotes and going round and round in search of cheaper suppliers,” he said. With his flexible working hours, and home base at Invergowrie House, David was able to act as a second project manager. He carried out his own quality checks and was available if Craigs Eco could not be on site first thing in the morning. Working for Scottish Water proved useful as he personally knew the water and sewage engineers that worked on the house. One of the most joyful moments came when the Polish joiners put together the wooden frame on site. “It would have been tricky to build it off site and then crane it in as there wasn’t a lot of space. They constructed the ten massive panels on the foundation slab, then we pulled them into place with a crane. They all slotted together like Lego, and it was one of the most fun things I’ve ever seen. The joiners only spoke broken English, but they worked overtime and I was so impressed I gave them a

Photos: David Barbour

bonus of a bottle of whisky and a wood-turning machine,” David said. The construction process went smoothly, and the couple moved into the house in June 2019, with baby Ruby who was born at the start of the construction process. There was still work to do furbishing the house with contemporary designs, which Jenny had lots of ideas about. But right from the start, living in Fenton House was an almost surreal experience of comfort and spaciousness after four years in a cold basement flat. Even during lockdown, with the entire family at home, bills have been low. “Our electric bills were about £1,200 for the year and we are running an electric car, an electric mower to cope with gardening on an industrial scale. And Jenny, who is a partner in a dental practice, has been running three loads of the washing machine every day of the week because of all the PPE gear. Heating has cost virtually nothing,” said David. Having the bedrooms on the ground floor makes them slightly cooler, but David and Jenny like it that way. On the rare hot Dundee days, the building’s natural ventilation is able to cool the house. Opening the roof lights can draw air through the whole building. The sliding patio doors are another option. The house is also set up to meet accessibility requirements. It could be retrofitted with a stairlift and there is space for wheelchair storage. Kirsty says it would even be possible to set it up as a ground-floor flat only. The couple have no plans to move anywhere else. “David is planning to be carried out in a box,” she said.

D U N D E E PA S S I V E H O U S E

David believes Fenton House will be a magical place for his children (the couple had another baby just as Passive House Plus went to print, after we interviewed David for this article). He has built a large climbing frame, but when they tire of that, there are all the mature trees to climb. Deer and foxes are seen daily. “I couldn’t imagine a better house for a family. Ruby is the jammiest kid in Dundee and the next child will be even luckier. We get loads of people coming to visit, and it inspires them to think about building their own passive houses.”

I designed a series of four pitched roofs.

ph+ | dundee passive house case study | 53


D U N D E E PA S S I V E H O U S E

CASE STUDY

EMBODIED CARBON

A

n analysis of the building’s whole life carbon score was conducted by John Butler Sustainable Building Consultancy, using PHribbon. Based on a cradle-to-grave analysis, the building totalled 496.8 kg CO2e/m2 GIA – a total which in large part reflects the fact that the analysis assumes the stored CO2e from the timber and timber-based products is released after sixty years (the standard lifespan for the assessment, in line with the RICS whole life carbon methodology.) From cradle to practical completion, however, the building has a total of 353 kg CO2e/ m2 GIA, with a further 216 kg CO2e/m2 stored in the timber and timber-based products at that point. The analysis also compared the as-built external walls against a cavity wall version to the same spec. The as built walls showed a small reduction compared to the cavity wall when considered on a cradle to grave basis, from 221 kg CO2e down to 194 kg CO2e/m2. But at practical completion, the difference is far more marked: 224 KG CO2e down to 154 kg CO2e – and with 131 kg of stored CO2e in the as-built walls, versus just 15 kg in the cavity walls. The analysis included the external envelope, internal walls, floors, and finishes. The stairs were excluded, as was the balcony, and the only internal fixtures included are the sinks/basins/WCs. Due to the absence of environmental product declarations for the heat pump, MVHR system and ductwork, data from the closest comparable certificates was used, drawing from the Product Environmental Passport database – albeit with data for stainless steel ductwork instead of the polypropylene ductwork that was used. The analysis assumed no replacements of building fabric during the projected sixty-year life

54 | passivehouseplus.ie | issue 38

but assumed three replacements of the hot water heat pump, two replacements of the hot water pipes, sanitary ware and sinks, and one replacement of the PV array and MVHR system. The radiant panels and electric towel rails weren’t included, due to lack of data. The entire superstructure of internal and external walls and roof (and window frames, excluding any aluminium cladding) is made from timber and timber-based products, so it’s perhaps unsurprising that they represent the largest chunk of embodied carbon in the building, at a combined total of almost 84 kg CO2e/m2 – though they also provide over 216 kg of sequestered CO2e, meaning these materials store more than 2.5 times as much CO2 as their manufacturing process emitted – at least for as long as they remain in the building. The next largest chunk of emissions is the zinc cladding and roofing at almost 57 kg CO2e/m2, followed by the PV at 50 kg CO2e/m2, and the concrete from the foundations at 38 kg CO2e/m2, with inert products – including glazing, plasterboard, plaster and ceramics – at 34 kg CO2e/m2, with over 39 kg CO2e/m2 relating to bringing materials from the factory gate to the site. Much of this is specific to the concrete – over 42 per cent of that figure is associated with the concrete supply. A treemap lays the cradle to grave figures bare: building-related services, including the PV array, the hot water heat pump and MVHR system, represent 27 per cent of the total, with the roof, external walls and substructure at 20, 18 and 16 per cent respectively. Although triple glazed windows have been criticised as being too high an embodied carbon cost by some high-profile life cycle assessment experts, in this case the total for windows, doors and rooflights only reaches 5 per cent of the total.

Embodied Co2e Comparison: Cradle to Grave, External Walls Only 120 100 80 60 40 20 0 -20 -40 -60 Cavity As Cavity As Cavity As Cavity As Wall Built Wall Built Wall Built Wall Built

Module A

Stored CO2

Module B

Module A: Concrete Module A: Inert Module A: Oil Based Module A: Zinc Module A: A4 Transport to Site Module A: A5 Construction Module A: Aluminium Module A: Brick Stored CO2: Timber Stored CO2: Timber Based Module C: Demolition & Disposal

Module C


CASE STUDY

D U N D E E PA S S I V E H O U S E

CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

7

8

9

1 Insulated raft foundation to minimise thermal bridging; 2 the timber frame sections being craned into place, with baby for scale; 3 Steico wood fibre batts, seen here waiting to be installed, were used throughout the walls and roof to insulate the I-joists; 4 while Steico wood fibre boards were used externally on the roof and walls; 5 each of the roof apexes has a glulam beam and an airtight layer above it; 6 airtightness membrane to walls and roof, and taping around thermally broken windows; 7 a blower door airtightness test being carried out; 8 & 9 plywood was installed over the Steico wood fibre board on three of the four sections, with zinc cladding then attached to the plywood, while the fourth section was clad with larch.

ph+ | dundee passive house case study | 55


D U N D E E PA S S I V E H O U S E

CASE STUDY

ADVIE06_PH_v1

© GettyI mages

END OF THE BALANCING ACT

THE FIRST NSAI CERTIFIED DEMAND CONTROLLED VENTILATION SYSTEM Ventilation doesn’t have to be a balancing act. Aereco has achieved Ireland’s first Agrément certification for Demand Controlled Ventilation. A system that self balances and automatically adjusts to the needs of a home, securing indoor air quality and energy savings. The National Standards Authority of Ireland (NSAI) Agrément provides a pathway that has significantly simplified the commissioning and validation process of Aereco systems. Aereco is committed to constantly innovating and improving the performance of their systems. Along with the recent release of their control indicator as part of the updated regulations for Part F, Aereco is reaffirming this commitment.

For more information: www.aereco.ie 56 | passivehouseplus.ie | issue 38


CASE STUDY

D U N D E E PA S S I V E H O U S E

SELECTED PROJECT DETAILS Client: David & Jenny Arrenberg Architect: Kirsty Maguire Structural design: Burnett Consulting Engineers Passive house designer: Kirsty Maguire Main contractor: Craigs Eco Construction Ventilation: Paul Heat Recovery Scotland Air source heat pump: Luths Services Windows & doors: Green Building Store Wood fibre insulation: Steico Airtightness testing: Thermal Image Scotland Insulated foundation: Advanced Foundation Technology Roof windows: Fakro Zinc cladding: HL Metals Flooring: West End Flooring Lighting: Terkan

WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on passivehouseplus.ie & passivehouseplus.co.uk

ph+ | dundee passive house case study | 57


D U N D E E PA S S I V E H O U S E

CASE STUDY

THE NEW ISOVER SOLUTIONS GUIDE Get the latest insulation, airtightness & dry lining solutions, as well as sustainability guidance, regulatory advice and case studies, from ISOVER.

AVAIL AB LE

NOW!

GET YOUR FREE COPY HERE

https:/www.isover.ie/solutions-guide 58 | passivehouseplus.ie | issue 38


CASE STUDY

D U N D E E PA S S I V E H O U S E

IN DETAIL Building type: 181 m detached two-storey timber framed house. 2

Location: Dundee, Scotland Completion date: May 2019 Budget: £330,000 approx, including all fees Passive house certification: Not certified Space heating demand (PHPP): 15.5 kWh/ m2/yr (PHPP carried out at design stage) Heat load (PHPP): 11.2 W/m2 Primary energy renewable (PHPP): 55 kWh/m2/yr Primary energy non-renewable (PHPP): 110 kWh/m2/yr Heat loss form factor (PHPP): 3.27 Overheating (PHPP): 0 per cent of the year above 25C Number of occupants: 4 Environmental assessment method: N/A Airtightness (at 50 Pascals): 0.66 m3/hr/m2 Energy performance certificate (EPC): A 93 Measured energy consumption: 6,697 kWh or 37 kWh/m2 (August 2019 to August 2020, measured electricity consumption).

Thermal bridging: Insulated raft foundation to minimise slab edge thermal bridge; I-joist construction with continuous wood fibre external insulation around all walls and roof to minimise thermal bridges; acrylic fixings for external wood fibre insulation; over-insulated window frames; thermally broken windows; thermal bridges designed out as far as possible through overall design. Valley gutters over-insulated to minimise thermal bridges. Energy bills (measured): £1,425 per year, for all electricity (includes space heating and hot water). This includes charging an electric car and electric mower for the grounds. Minus an average annual feed in tariff of £150 gives a net energy bill of £1,275 per or £106 per month. Ground floor: 150 mm compacted base, followed above by 25 mm sand blinding, 1 mm damp proof membrane, 250 mm EPS insulation, 200 mm reinforced concrete slab, floor finish. U-value 0.124W/m2K Walls: Zinc or timber rainscreen cladding, followed inside by 50 mm ventilated cavity, 100 mm Steico wood-fibre board, 240 mm I joists stuffed with Steico wood-fibre batts, 12 mm OSB, Intello Plus airtightness membrane, 50 mm services cavity with softwood battens, plasterboard. U-value 0.115 W/m2K Roof: Zinc roofing, on 22 mm softwood sarking boards, on 50 mm ventilated cavity with 50x50 mm softwood boards, on 100 mm Steico wood-fibre board externally, followed beneath by 240 mm I joists stuffed with Steico wood-fibre batts, 12 mm OSB, Intello

Plus airtightness membrane, 50 mm services cavity with softwood battens, plasterboard. U-value 0.116 W/m2K Windows & external doors: Green Building Store Progression triple glazed windows. Passive House Institute ‘A’ certified component. Standard whole window U-value: 0.68 W/m2K. Green Building Store Ultra doors. Roof windows: 3 x Fakro U8 triple glazed roof windows. U-value: 0.8 W/m2K Heating system: Ecocent Ambient air source heat pump for water heating only with 300 litre integrated cylinder. Space heating provided by Trotec infrared panel heaters and low wattage towel rails. Ventilation: Zehnder ComfoAir Q350 heat recovery ventilation system. Passive House Institute certified to have heat recovery rate of 90 per cent. EN 308 certified efficiency of 93-96 per cent. Water: Rainwater soakaway as opposed to connection to sewer. Electricity: 3.99 kWp solar photovoltaic array, ground mounted. Provides electricity to general household supply with any excess exported to the grid. Green materials: Wood fibre insulation for all floors and walls, timber cladding (heat treated larch), fully recyclable zinc cladding, insulated foundations, glulam beams, locally sourced timber frame.

ph+ | dundee passive house case study | 59


KINGS’S COLLEGE

CASE STUDY

ENERGY BILLS

£364

PER MONTH – OR £6 PER STUDENT FOR SPACE HEATING (Estimated, see ‘In detail’ for more) Building: Two graduate student accommodation buildings (1,091 & 435 m2), for 59 occupants Build method: Cross-laminated timber Location: Cambridge, England Standard: Passive house certification pending

60 | passivehouseplus.ie | issue 38


CASE STUDY

KING’S COLLEGE

K I N G’S C O M F O RT CAMBRIDGE CHOOSES PASSIVE HOUSE COMFORT FOR KINGS’ COLLEGE STUDENTS

Most people think of cold, cramped and poor-quality buildings when they think of student accommodation, but two new passive house residences at King’s College, Cambridge are rewriting the rulebook, with their focus on occupant comfort, architectural quality, and an enlightened, long-term view of construction costs. Words by Anthea Lacchia

ph+ | king’s college case study | 61


KINGS’S COLLEGE

CASE STUDY

C

ompleted at the end of 2019, Cranmer Road provides much-needed accommodation for the graduate students of King’s College at the University of Cambridge. The accommodation is located in West Cambridge, a ten-minute walk from campus, and includes two separate buildings: the three-storey Villa building, with 19 bedrooms, and the two-storey Stephen Taylor building with 40 bedrooms. This all-electric, passive house project was designed by Allies and Morrison Architects, with Max Fordham engineers providing passive house consultancy, as well as mechanical and electrical system design. The project was born out of a need for more student accommodation in Cambridge, says Shane Alexander, project manager and clerk of works at King’s College. “Prior to that, a lot of our graduates had to seek private accommodation within Cambridge,” he says. The passive house design ties in with the university’s aspirations to build sustainable housing for students and staff. “We’ve always wanted to get to the point where we would lower our carbon footprint and really focus on sustainability. Cranmer was really the first of many [projects] to head down that road,” Alexander says. The buildings, which were fully funded by a donor, sit west of the River Cam, at the heart of the West Cambridge conservation area, with its large houses and colleges, generous gardens and sports grounds. The architectural legacy of the area includes characteristic red-bricked villas designed in the late nineteenth and early twentieth centuries as part of the Arts & Crafts design movement. “It was a real uphill struggle to get planning permission to develop the site,” recalls project architect Matthew Traub. “It was only through a really careful consideration of the architectural heritage of West Cambridge that we developed proposals that were permissible by the local planning authority.”

62 | passivehouseplus.ie | issue 38

He says the design team perceived West Cambridge as having a dual character, with Arts & Crafts villas sitting alongside mid-20th century modernist university buildings. It is precisely this dual architectural language that inspired and guided the design of Cranmer Road. The Villa building, with its red brick facade, was designed as a contemporary response to the Arts & Crafts villas of the area, capable of sitting comfortably and “filling a gap in the frontage along Cranmer Road, where you have a consistent rhythm of Arts & Crafts villas,” says Traub. The Stephen Taylor building, with its exposed precast concrete structure and louvres

of glazed terracotta baguettes, responds to the more contemporary language of the university and college facilities, while subtly referencing the tones and textures of the Arts & Crafts buildings. King’s College specified a 100-year design life for the buildings, says Traub, and, while passive house was not a requirement from the start, it soon became “a really interesting opportunity,” he says. “The fact that it’s a comfort-driven metric was really important for the college,” he adds, as were the benefits in terms of energy use and sustainability. A lifetime cost assessment prepared by Faithful and Gould consultants highlighted a


CASE STUDY

2.3 per cent saving over 60 years across maintenance costs, operational costs, and cost of renewals with passive house, as opposed to no savings with a low energy approach or merely a regulations compliant approach. “When you combine that with the benefits in terms of the comfort of the space and consider a 100-year timescale, that was a really compelling case for the college to stomach the additional uplift in terms of capital costs for the long-term value of a passive house building,” Traub says. Indeed, there was an additional up-front cost to incur in building to the passive house standard, notes Alexander, for which there won’t be a return for about 35 years. However, “35 years in the lifespan of the college is nothing really,” he says. He estimates this cost uplift to be about £1.5m, or 10 per cent of the total project cost, and says this includes the cost of extra insulation, more thermally efficient windows and doors, PHPP modelling, and airtightness sealing. Cranmer Road’s interiors are bright, airy and spacious, with large common rooms and dual aspect kitchens. Four of the bedrooms are accessible to wheelchair users, an element the College was keen to provide. Other notable features include a wastewater heat recovery system in the shower drains, and openable window panels hidden behind terracotta baguettes in the Stephen Taylor building. Shutters can be added to the precast concrete structure along the south-facing corridor of the Stephen Taylor building to adapt to warmer conditions in the future. The structure and services of the building were also designed to be able to take an additional floor in the future. This was the first passive house project to occupy Gwilym Still, chartered engineer and passive house designer at Max Fordham building services engineers. “We had a practice-level interest in passive house, and I’d been interested in it for a while because it was one of the ways

Photos: Nick Guttridge

in which people talked about delivering really low-energy buildings,” he says. CLT with five plywood layers was the preferred structural solution and main air tightness line for both buildings at Cranmer Road. Airtightness was one of the main challenges, recalls Still, as it is evaluated through a single test which you either pass or fail, and which “tends to get everybody a bit scared.” Working with the design team and contractors, Still and his colleagues looked at different airtightness strategies, including using plaster, an external membrane, or the CLT itself for air-

KING’S COLLEGE

The students liked the air quality, the design, the communal spaces, and the amount of daylight.

ph+ | king’s college case study | 63


KINGS’S COLLEGE

CASE STUDY

King’s College specified a 100-year design life for the buildings.

tightness. “We settled on either the CLT or the membrane because we wanted to have something that we could test fairly early on in construction, and went for the CLT itself because it seemed like a more robust choice.” Structural engineers Smith and Wallwork, who have extensive experience with CLT, also played a big part in designing the airtightness strategy. “The sequencing was set out so that we could get the primary structure and the windows in early on [...], when the whole airtight envelope was still accessible, [in order to ensure] tests could be done and any issues could be fixed early,” Still says. CLT joints were taped with tapes from Pro Clima, and the damp proof membrane in the ground was lapped onto the base of the CLT. The team opted for an all-electric heating system because decarbonisation of the national grid is likely to take place over the lifetime of the buildings, says Still, rendering electricity a lower carbon fuel source than gas. Simplicity was also key guiding principle in the project. “We were generally trying to keep the systems as simple as possible,” says Still. “Having electric panel radiators is a really simple and fairly cost-effective way of delivering low-carbon heat into the buildings,” he explains. Heating storage was kept to a minimum and the water heaters are all very close to the outlets, with pipework between the water heaters and the showers kept as small and short as possible.” Too much pipework for hot water can create a risk of overheating in a passive building, especially when you factor in future climate change. This was one of the reasons why a point of use system for hot water — where water is heated close to where it is used - was chosen. Still combined meter reading data and software modelling to study energy consumption and heating in the buildings. Metering data shows that domestic hot water consumption is the highest energy draw within the building. Both buildings use mechanical ventilation with heat recovery, and post-occupancy feedback on summer comfort has generally been positive. Since completion, the buildings have been through two winters. The Passive House Planning Package (PHPP) models assured the team that buildings would perform well in cold weather. Measured heat load, the amount of heat energy a building needs to maintain 20 C on the coldest day of winter, was 8 W/m², lower than the passive house target of 10 W/m². According to Still, heat load is a particularly good indicator of the thermal performance of the building envelope, because it is less influenced by changes in the thermostat setpoint than the other key metric of thermal performance, space heating demand. “We also have longitudinal data showing that, once the buildings were occupied, some of the heating demand was higher than expected,” says Still. Specifically, the PHPP software indicated that space heating demand,

64 | passivehouseplus.ie | issue 38


CASE STUDY

KING’S COLLEGE

CONSTRUCTION IN PROGRESS

1

2

3

4

5

6

7

8

9

1 The ground floor features an unbroken raft of 200 mm Cellecta Hexatherm Xfloor 500 insulation; 2 aerial view of the site, with concrete slab in place and work commencing on the CLT structure; 3 & 4 construction of the CLT frame underway; 5 CLT joints taped with pro clima tapes, and installation of the Internorm triple glazed timber-aluminium windows; 6 installation of the BauderTEC KSD vapour control layer to roof featuring CLT dormers; 7 wall build up featuring brick externally, followed behind by drained cavity, Knauf Earthwool rainscreen slab, and pro clima Solitex breather membrane; 8 ventilation in the Stephen Taylor building is provided by Airflow MVHR systems, supplemented here by an electrical heating coil to boost temperatures when necessary; 9 a blower door test under way; the buildings scored 0.16 and 0.19 air changes per hour.

the amount of active heating input required to heat a building over a year, was higher than the threshold of 15 kWh/m²/yr for one of the buildings: 13.1 kWh/m²/yr for the Villa building and 17 kWh/m²/yr for the Stephen Taylor building. This is possibly because the PHPP models are based on the whole building being at 20 C,”and we know that the students have overridden the thermostats to make their spaces warmer,” says Still. If you turn the heating up by about two degrees, the annual heating energy consumption goes up by about a third, so “it’s fairly sensitive to that change”, he says. Post occupancy evaluation was conducted with all students who have lived in the buildings. “Generally, feedback was very positive,” says Still. The students liked the air quality, the design, the communal spaces, and the amount of daylight. Points raised by the students included that they wanted more control over the

heating, feedback that is now being fed into a subsequent project for King’s College, and that the lights inside the bathrooms turned off after about 20 minutes, which was too short a period. This has now been adjusted. The students were involved right from the project’s outset. “We do that with all our projects,” says Alexander. For instance, as a result of consultation with the graduate community, the bedrooms in the Villa Building are not ensuite. “[For the students,] it was quite important to have a range of price points for accommodation. Some people want cheaper rent and are quite happy to share a bathroom,” explains Traub. Students also asked for a choice of carpet or hardwood floors being offered: “not everyone wanted carpets because some people suffer from allergies,” explains Alexander. The result of all these design and consultation efforts is a space where college life can

blossom. “King’s wanted to create a unified space for graduates to come together, learn together and feel like they play a part in the life of King’s College,” says Traub. Enjoyment of the outdoor spaces is a key part of college life, so a lot of thought went into the green spaces around the buildings, he explains. The gardens include pleached trees and allotment planting spaces for students, and the shared garden is split into a formal lawn and a meadow that accommodates more biodiversity. There is also a woodland with retained tree cover and a swale on the grounds. Cranmer Road went on to win the 2021 Cambridge Design and Construction Award for best new building over £2 million, as well as the sustainability and engineering prize at the same event. “The college is really pleased with it,” says Alexander, “to the extent that as soon as we started Cranmer Road we were already

ph+ | king’s college case study | 65


KINGS’S COLLEGE

CASE STUDY

Save energy. Build smart.

MAXIMUM FIRE PROTECTION, AIR & WINDTIGHTNESS, ENERGY EFFICIENCY Partel’s fire-rated product systems - IZOPERM™ PLUS FR Class A2 and EXOPERM™ MONO DURO Class B1 are key components in designing safe and durable low-energy projects. These high-performance tested solutions are designed to enhance the building fabric in terms of air and windtightness, moisture management, and energy efficiency, providing outstanding fire safety and smoke protection to the building and its occupants. Both systems are compliant with the latest Building Regulations Part L and Part B.

IZOPERM™ PLUS FR

EXOPERM™ MONO DURO

Advanced non-combustible vapour control layer Euroclass A2-s1, d0 to DIN 13501-1

Premium class of protective windtight membrane - Euroclass B-s1, d0 to DIN 13501-1

Superior airtightness and moisture management

Up to 10 years of UV protection for open joint facades

Designed for internal walls and ceiling, especially in high-rise buildings

Designed for the external walls and roof

Monolithic TPU Technology

Technology based on lacquered aluminium laminated with strong glass fibre

For maximizing the fire safety and airtightness within the building envelope, get in touch with our Technical Consulting Team.

PARTEL.IE | TECHNICAL@PARTEL.COM | 091 428 714 66 | passivehouseplus.ie | issue 38

scan for CONTACT FORM


CASE STUDY

KING’S COLLEGE

working on another [student accommodation] project, Croft Gardens, which will also be fully passive house certified.” “The students who moved into Cranmer absolutely loved the buildings,” he says, noting that “different groups of students have lived there now, and there’s never been a negative word said about the accommodation.” “We’ve learned a lot through the scheme,” says Still, “from airtightness, to structure design, ventilation, detailing, and proper insulation of the ventilation ductwork – we’re already applying our learnings in current projects.” “Quite different from the student accommodation I remember living in!”

SELECTED PROJECT DETAILS Client: King’s College, Cambridge Architect: Allies and Morrison Main contractor: RG Carter M&E engineering: Max Fordham, Ingleton Wood Passive house consultant: Max Fordham Structural engineering: Smith & Wallwork Project management: Faithful & Gould Quantity surveyors: Faithful & Gould Landscape architects: LDA Design Planning consultants: Turley Mechanical contractor: Munro Airtightness products: Ecological Building Systems CLT structure: KLH Primary wall insulation: Knauf Thermal wall ties: Ancon Teplo-L-ties, via Leviat Floor insulation: Cellecta Windows & doors: Internorm MVHR: Airflow & Zehnder Wastewater heat recovery: Recoup Electric underfloor heating: Raychem Electric radiators: Adax

WANT TO KNOW MORE? The digital version of this magazine includes access to exclusive galleries of architectural drawings. The digital magazine is available to subscribers on passivehouseplus.ie & passivehouseplus.co.uk

7

6

5 4

3

GARDEN BUILDING The passive house environmental strategy employed at Cranmer Road necessitates a careful approach to the design of the external fabric: engineering to minimise heat loss, reduce energy consumptions and consequently reduce carbon emissions. This fabric first approach is not immediately apparent when you see the building, balancing performance with aesthetics to deliver a quietly innovative and highly sustainable graduate campus. 1. Floating foundation: A foundation system that literally ‘floats’ the building on a thick layer of rigid insulation, ensuring that no heat is lost into the ground. 2. Structurally independent skin: The external cladding is hung from a structurally independent pre-cast concrete frame, minimising penetrations through the insulation to avoid unnecessary heat loss. 3. Triple glazed windows: Glazing that minimises heat loss and avoids cold spots around the windows. 4. Continuous insulation: A thick layer of insulation is maintained around the external envelope.

2

5. Airtight structure: A cross laminated timber structure with low embodied carbon doubles as the structure and primary airtight envelope. Minimising heat loss through escaping air by achieving an airtightness of 0.19 ACH.

1

6. Deep window reveals: Deep window reveals reduce the chances of overheating within the building. 7. Insulated roof: A layered roof build-up minimises heat loss by maintaining a continuous layer of rigid insulation.

ph+ | king’s college case study | 67


KINGS’S COLLEGE

CASE STUDY

Carbon Dioxide (CO2) Monitor and App Track CO2 levels and manage ventilation in your home, office or school using the CaDi CO2 monitor and free app CaDi connects to your WiFi router and you can use the app to monitor CO2 levels from anywhere. The LED traffic light bar on CaDi lets you know when CO2 levels are above recommended levels and you can see the exact reading in the app. By monitoring CO2 levels you can optimise ventilation, comfort and safety for building occupants.

OK

excl VAT

Fair

Poor

Ventilation Level

CO2 Level

Humidity

Temperature

Manufactured in Ireland by:

Switch Device

Jack’s Room

€1 165

OK

720 ppm

70 %

21 °C

• Free app for remote monitoring • Quick and easy setup on WiFi • View graphs to analyse CO2 by day, week and month • Designed and developed in Ireland by NuWave Sensors - experts in indoor air quality • Manage multiple devices via the app • Full API available for developers

Full range of air quality monitoring products available

Learn more or buy online from:www.nuwavesensors.com SENSORS

To discuss your project or for further information contact:

Tel: +353 1 254 4188 Email: info@nuwavesensors.com

THE TRIOTHERM SYSTEM The most advanced thermal bracket system for doors & windows + + + + + + + + +

highly load bearing less thermal bridging infinitely extendable easy to handle & cut resistant to ageing simplified building detail CE certified Passive House certified 100% recyclable

prodomo.ie

|

t +353 66 4014045

68 | passivehouseplus.ie | issue 38

|

e hello@prodomo.ie


CASE STUDY

KING’S COLLEGE

IN DETAIL Building type: Two graduate student accommodation buildings built with cross-laminated timber. Villa Building: 435 m² (treated floor area). Stephen Taylor Building: 1,091 m². Location: Cranmer Road, Cambridge, CB3 9BL Completion date: December 2019

buildings combined over the first five months of 2021, though the Covid pandemic may have affected occupancy patterns. This includes all standing charges but not VAT. Projection of space heating costs using PHPP figures estimates that the average monthly cost for space heating only will be £85 for the Villa Building and £279 for the Stephen Taylor Building, exclusive of both standing charges and VAT.

Project cost: £14,694,0000 Passive house certification: Pending Space heating demand (PHPP): Villa Building 13.1 kWh/m²/yr, Stephen Taylor Building 17.0 kWh/m²/yr Heat load (PHPP): Villa Building 8.2 W/m², Stephen Taylor Building 8.8 W/m² Primary energy renewable (PHPP): Villa Building 80.8 kWh/m²/yr, Stephen Taylor Building 75 kWh/m²/yr Primary energy non-renewable (PHPP): Villa Building 188 kWh/m²/yr, Stephen Taylor Building 171 kWh/m²/yr (figures are high because the building is all electric). Heat loss form factor (PHPP): Villa 2.4, Stephen Taylor 2.4 Overheating (PHPP): 0 per cent of year above 25C Number of occupants: Villa Building: 19, Stephen Taylor Building: 40 Airtightness (at 50 Pascals): Villa Building 0.16 ACH, Stephen Taylor Building 0.19 ACH Measured energy consumption: All electricity boards are metred in high resolution. Understanding exactly how much energy is used within the buildings has been complicated by a global pandemic. Figures are based on monitoring from January to April 2020. Monthly energy use for each of domestic hot water, kitchens, lighting, plant, small power, and miscellaneous items was consistent during this period, so these figures were extrapolated over a whole year. Initial monitoring showed a delivered energy use intensity (EUI) of 51 kWh/m²/yr across both buildings. This was reviewed later in the year, after client feedback that some of the occupants had overridden the temperature control on the radiators. The total EUI had risen to 71 kWh/m²/yr, which included metred space heating usage. The assessment included the superstructure, substructure, external and internal walls, glazing, staircases, and finishes to walls, ceilings and floors, but does not include mechanical and electrical equipment. Energy bills (measured or estimated): Electricity bills, covering all energy use, averaged £2,202 per month for the two

Thermal bridging: CLT was used as primary structure, with a raft foundation for both buildings. Rawlplug fixings to hold insulation against CLT. Low-conductivity brick ties were used (Ancon Teplo L-Ties). Overall thermal bridging figures are: Stephen Taylor Building: 1.6 kWh/m²/yr. Calculated from PHPP at 0.0080 W/m²K (m² of total thermal envelope) Villa building: 3.7 kWh/m²/yr. Calculated from PHPP at 0.019 W/m²K (m² of total thermal envelope). Embodied carbon: An analysis was carried out of the embodied carbon of the buildings by Allies and Morrison using an in-house tool the firm developed. It only included life cycles stages A1 to A3 (raw material supply to manufacturing), so did not include the construction process itself, transport to site, or the use phase or end of life. It produced the following results: Gross embodied carbon values: Villa building: 390.5 KgCO2eq/m², Stephen Taylor building: 392.5 KgCO2eq/m². Gross embodied carbon values incorporating carbon sequestration of the CLT: Villa Building (A1-A3): 110 KgCO2eq/m², Stephen Taylor building (A1-A3): 134.1 KgCO2eq/m². The analysis includes superstructure, substructure, external walls, glazing, internal walls, floor, ceiling and roof finishes. It does not include mechanical, electrical and plumbing services. Ground floor (both buildings): Concrete slab on an unbroken raft of 200 mm Cellecta Hexatherm Xfloor 500 (2 x 100 mm layers of insulation, shiplap joints, joints staggered). 900 mm strip foundation at the perimeter. U-value 0.167 W/m²K Walls (typical) Villa Building: Brick externally, with a 75 mm drained cavity, 225 mm Knauf Earthwool rainscreen slab, pro clima Solitex breather membrane, CLT structure (120 mm), timber stud 40 mm deep with 25 mm Rockwool to inner face, 15 mm unventilated air gap, 30 mm plasterboard internally. U-value: 0.115 W/m²K

counter-battens generally, on pro clima breather membrane, on 160 mm Kingspan Kooltherm PIR insulation, on vapour control layer, on 100 mm CLT structure, on 50 mm mineral wool, on 50 mm unventilated timber studs, on 25 mm plasterboard internally. U-value: 0.11 W/m²K Stephen Taylor Building: Brown roof generally followed underneath by 130 mm EPS insulation, 200 mm PIR insulation (Innobond), vapour control layer, 100 mm CLT structure, 50 mm mineral wool, 70 mm unventilated air gap (timber & aluminium studs), 25 mm plasterboard. U-value: 0.06 W/m²K Windows & external doors: Generally, Internorm HF310 triple glazed timber-aluminium windows throughout both buildings. Internorm AT200 aluminium entrance doors & Internorm HS330 Internorm HS330 triple glazed timber-alu life-and-slide doors. Roof windows: Gorter glazed roof hatches to Villa building with HR+++ triple glazing. Gorter RHTEP insulated roof hatches to Stephen Taylor building. Heating system: Generally, Adax Neo Stylish electric panel radiators through both buildings, plus electric towel rails to bathrooms. Electric underfloor heating to the common room in the Stephen Taylor building. Electric panel radiators in each bedroom have in-built controls, including thermostat, timeclock, and open window detection functionality. Electric towel rails in ensuites have push-button which lets the heater run for a limited time period. Electric underfloor heating in Stephen Taylor building is controlled by local thermostat. Ventilation Villa building: 2 x Zehnder ComfoAir Q600 units, Passive House Institute certified efficiency 87 per cent. Stephen Taylor building: 10 x Airflow DV Entro 400 units, Passive House Institute certified efficiency 88 per cent. 3 x Zehnder ComfoAir Q600 units, certified efficiency 87 per cent. Water: Low flow sanitaryware – 6 l/min showers. Wastewater heat recovery from Recoup.

Stephen Taylor Building: Precast concrete and brick externally with a 60 mm drained cavity, 240 mm Knauf Earthwool rainscreen slab, pro clima breather membrane, CLT structure (120 mm), timber stud 40 mm deep with 25 mm Rockwool to inner face, 15 mm unventilated air gap, 30 mm plasterboard internally. U-value: 0.115 W/m²K Roofs (typical) Villa Building: Clay tiles on battens &

ph+ | king’s college case study | 69


PHAI EMBODIED CARBON REPORT

INSIGHT

S IX OF ON E AN ANALYSIS OF THE EMBODIED CARBON FROM SIX WAYS OF BUILDING A HOUSE

The climate emergency demands that we minimise the energy we use to operate buildings, as well as the energy we use to construct new buildings, where new buildings are needed. A Passive House Association of Ireland-commissioned analysis may start to shed some light on the embodied carbon impact that different build methods can have. Words by Jeff Colley

T

he embodied carbon of walls and foundations on new homes can be cut by 50 per cent or more, an analysis commissioned by Passive House Association of Ireland (PHAI) has revealed. The PHAI commissioned the Association for Environment Conscious Building (AECB) to conduct the analysis using PHribbon, a tool which enables embodied carbon to be calculated via the PHPP passive house design software. The AECB calculated the cradle-to-grave embodied carbon emissions of a 76 m2 end of terrace house provided by Cork City Council. The building was modelled in Sketchup by AECB chief executive Andy Simmonds, with the calculations carried out by PHribbon creator Tim Martel, working in collaboration with the author, and fellow PHAI board member John Morehead.

70 | passivehouseplus.ie | issue 38

The house was designed to meet compliance with Ireland’s nearly zero energy building (NZEB) standard, including the following energy performance specifications: U-values W/m2K Walls: 0.145 – 1.64 Roof: 0.105 – 0.134 Floor: 0.101 – 0.137 Windows: 1.15 Doors: 1.1 Y-factor: 0.06 Mechanical extract ventilation Airtightness: 3 m3/hr/m2 at 50 Pa. Heating system: 6 kW air-to-water heat pump

Wain Morehead Architects prepared DEAP calculations to demonstrate that the specification complied with Ireland’s NZEB requirement for dwellings. Building LCA modules: a brief explanation With embodied carbon assessment generally there are certain areas where it’s possible to reach relatively clear conclusions with high degrees of confidence, while other aspects of the calculation may be more speculative. Life cycle assessment is divided into four modules: A, B, C and D. Module A deals with the building construction up to the point of practical completion. This is the area where there is most scope for accurate embodied carbon calculation, for the simple reason that it involves assessing the impact of works that have been done.


INSIGHT

BASE CASE 1A

Walls 12.5 mm plaster 100 mm blockwork 140 mm PIR 100 mm blockwork 19 mm 1:4 cement: sand render Floor 20 mm engineered timber floor 75 mm cementitious screed 150 mm PIR 225 mm concrete + strip foundation 150 mm aggregate A1-A3 (materials only, cradle to factory gate): 18.8t CO2e A1-A5 (cradle to practical completion): 25.2t CO2e A-C (cradle to grave): 25.2t CO2e Stored CO2: -1.1t CO2e

Module B deals with the use phase, including maintenance, repair, replacement and refurbishment. (It can also include operational energy use, but this is reported separately in the RIBA 2030 Climate Challenge, and in this analysis). It therefore involves making predictions about how the building will be operated, and about how long certain components may last. This can be affected by the quality of component, or by the quality of the design and construction, and also by occupant behaviour. For instance, if a building design hasn’t adequately considered surface or interstitial condensation risk, this may result in mould growth and potential for

redecorating, repair to building fabric and in catastrophic cases, reducing the lifespan of the building. This can be exacerbated with occupant behaviour – especially where occupants are underheating or under ventilating buildings, hanging clothes indoors to dry, or placing furniture against external walls. Module C deals with the end of life of the building. In line with the RICS methodology, this analysis assumes a 60 year lifespan. In reality, it is to be hoped that the lifespan is far longer. The historic replacement rate of housing stock in the UK is 0.5 per cent per annum, indicating that a 200 year lifespan should be possible for the main elements of a building. At the building’s assumed end of life, CO2 emissions associated with deconstruction/demolition are added. Emissions locked up in timber and timber-based products are assumed to be released at this point. The default assumption is that 75 per cent of timber is incinerated, and therefore the CO2 is released, with 25 per cent being landfilled, and breaking down as methane, which has a considerably higher global warming potential than CO2, and actually increases the CO2 equivalent (CO2e) figure more than incineration would. Even if it’s assumed that the timber is in fact reused or recycled instead, the sequestered CO2 moves outside of the boundary conditions of the life cycle assessment. The benefit passes on to the next use – meaning the LCA effectively regards it as being released into the atmosphere anyway. Module D deals with the potential for reuse, recovery and recycling, beyond the boundaries of the LCA. These figures can’t be included in the cradle to grave figures, so we’ve elected not to include them in this analysis. A particular focus on Module A is illustrative. A1 to A3 relates to the upfront emissions in manufacturing the materials – everything emitted up to the factory gate. A4 relates to transporting those materials from the factory gate to the site, and A5 relates to the construction process itself. The data available presently tends to be clearest with regard to module A1-A3, as a growing number of manufacturers have already obtained Environmental Product Declarations (EPDs) or a French equivalent, the Product Environmental Passport (PEP), both of which include independently audited embodied carbon values for given products. There are also generic EPDs organised by industry bodies, which are intended to provide typical results for a given product type. These are less accurate than EPDs for specific products, for the very obvious reason that they don’t relate to a specific product. The vast bulk of EPDs tend to exist for building fabric products. Manufacturers of mechanical, electrical and plumbing products have tended to be less likely to obtain EPDs, though some relevant data is now available via the PEP database (www.pep-ecopassport.org). This analysis focuses on the materials in the building fabric: the substructure (including insulation, cement-based screed and hardwood flooring), the external walls, windows and doors, internal walls and intermediate

PHAI EMBODIED CARBON REPORT

floors, the roof, and internal finishes to a builder’s finish. The heat pump is included, but there is no allowance for plumbing and heating distribution systems, electrics and lighting, the ventilation system, sanitaryware, bathroom and kitchen fitout, staircase, or for furniture, fixtures and equipment generally. Similarly, with the fabric, some information has been omitted in certain cases: such as wind posts and cavity closers. We have elected not to name proprietary products in general, although where possible, values were taken from actual EPDs for proprietary products. It is relatively tricky to obtain accurate data

BASE CASE 1B

Walls 12.5 mm plaster 100 mm blockwork 140 mm PIR 40 mm air gap 102.5 mm brick Floor 20 mm engineered timber floor 75 mm cementitious screed 150 mm PIR 225 mm concrete + strip foundation 150 mm aggregate A1-A3 (materials only, cradle to factory gate): 20.7t CO2e A1-A5 (cradle to practical completion): 27.3t CO2e A-C (cradle to grave): 27.7t CO2e Stored CO2: -1.1t CO2e

ph+ | phai embodied carbon report insight | 71


PHAI EMBODIED CARBON REPORT

UPGRADE 1

INSIGHT

undertaking for this analysis. For instance, take the case of concrete foundations. While there are concrete product manufacturers relatively local to the site of the project in this analysis, not all of the ingredients would have been sourced at or near the factory. Also, while return journeys may not be an issue with national or international travel – in many cases articulated lorries delivering materials to a local depot would be taking other goods on return journeys – this is much less likely with smaller rigid lorries, meaning a 50 km local freight assumption may be an underestimate. In line with the RICS methodology, the default data for emissions related to the construction process (A5) is based on the economic value of the project. The analysis includes certain elements which remained common in all cases: the roof and ceiling build up, internal walls and intermediate floor, windows, concrete sills and lintel, and heat pump. The only areas where variations were assessed included the external walls and the ground floor spec, including foundations. A health warning is necessary on the concrete figures. Data for the foundations in the base case was sourced from an EPD for a CEM

wall insulation (EWI) and a silicone-based render system. Upgrade 2A and 2B include EWI with render and brick slips respectively, and in both cases substitute the strip foundation for an insulated raft foundation system, including 50 per cent substitution of ordinary Portland cement (OPC) with GGBS. Upgrade 3 retains the same insulated foundations spec, but switches to a cellulose-insulated timber frame wall, finished with a rendered cement board system. Material impacts: walls and floors It is worth first considering the embodied carbon emissions of materials by the time they leave the factory gate, given that it’s possible to pin down these figures with greater certainty, and to focus first on the areas where variations were considered: external walls and foundations. The worst performing option in this case is Base Case 1B, the brick-clad cavity wall build, which comes in at 20.1 tonnes of carbon dioxide equivalent (CO2e), a measurement used to compare emissions of all greenhouse gases based on how their warming impact relates to that of carbon dioxide. Simply switching from brick to a rendered block outer leaf (Base Case 1A) drops the

The best performing option is Upgrade 3, the timber frame build on insulated foundations, which comes in at 9 tonnes of CO2e. Walls 12.5 mm plaster 215 mm blockwork 8 mm scratch coat 200 mm EPS 6 mm proprietary silicone render 450 x 150 mm PUR Aircrete block course in foundation wall Floor 20 mm engineered timber floor 75 mm cementitious screed 150 mm PIR 225 mm concrete + strip foundation 150 mm aggregate A1-A3 (materials only, cradle to factory gate): 17.2t CO2e A1-A5 (cradle to practical completion): 23.6t CO2e A-C (cradle to grave): 24.9t CO2e Stored CO2: -1.1t CO2e

on transport to site (A4). PHribbon includes default assumptions on transport based on UK government data on freight emissions, with different estimates per tonne km for sea freight, national road freight and local road freight. Based on the RICS methodology, PHribbon includes default transport distances of 300 km for national freight on an articulated lorry, and 50 km local freight on a smaller rigid lorry. In some instances, estimates have been made based on likely actual distances, but in practical terms this was often too much of an

72 | passivehouseplus.ie | issue 38

I-based concrete – where 95 per cent or more of the cement is clinker (the active ingredient in cement). A lower embodied footprint would have been achieved by using CEM II – which has become the default product for most concrete applications in Ireland, excluding precast concrete. However, CEM II cement has a broad bandwidth – comprising from 65 per cent up to 95 per cent cement clinker, with different options for additions such as GGBS, fly ash or limestone – meaning it’s unclear how much of a reduction compared to CEM I that CEM II will achieve, unless the cement manufacturer has declared the amount and type of additives used in the CEM II cement. The figures for concrete blocks are derived from an industry association EPD, which doesn’t specify the type of cement used – meaning it’s not possible to reach conclusions on its constitution. The analysis established two base cases, Base Case 1A and 1B, derived from what was considered to be a typical Irish reference: a cavity wall building with strip foundations, with both the floor and cavities insulated with oil-based insulation board. The only difference between the two was the outer leaf: rendered blockwork in the case of Base Case 1A, and a brick outer leaf for Base Case 1B. Upgrade 1 includes one change: instead of cavity walls, it includes a single leaf 215 mm block-on-flat fitted with oil-based external

total to 18.2 tonnes. Switching to single leaf 215 mm blockwork with rendered external insulation as per Upgrade 1 drops the total to 15.4 tonnes. A further significant drop to 11.4 tonnes is achieved in Upgrade 2A by switching from conventional foundations to an insulated foundation system with 50 per cent GGBS. Upgrade 2B sees the total rise again to 13.8 tonnes, due to switching from a rendered finish to brick slips. The best performing option is Upgrade 3, the timber frame build on insulated foundations, which comes in at 9 tonnes of CO2e. Sequestered CO2 It’s important to treat the sequestered CO2 figures with care. After all, timber-based construction products don’t suck CO2 out of the air – forests do. The notion of achieving carbon negativity by using vast quantities of timber may be too simplistic. But notwithstanding issues around the need for broader attention to sustainability in forestry management, a strong environmental case can be made for lean timber-based approaches, such as those that make structural use of Larsen trusses or I-beams. Upgrade 3 in this analysis therefore opted for just such an approach. In terms of the wall and floor analysis, the sequestered CO2 in the timber and timber-based products used, including cellulose insulation – is


INSIGHT

almost equivalent to the entire A1-A3 emissions for the wall and floor. However, this is not to suggest that one figure should be netted off against the other. While there is a value in keeping CO2 sequestered in buildings – hopefully for centuries – perhaps the more significant point is that by stage A1-A3, the timber frame and insulated foundation option in this analysis had emitted less than 40 per cent of the emissions of the brick-clad base case. This is not down to the timber frame alone, but to the application of a combination of

UPGRADE 2A

Walls 12.5 mm plaster 215 mm blockwork 8 mm scratch coat 200 mm EPS 6 mm proprietary silicone render 450 x 150 mm PUR Thermal (AAC) block course in foundation wall Floor 75 mm screed 200 mm concrete (50% GGBS) 250 mm EPS150 A1-A3 (materials only, cradle to factory gate): 11.4t CO2e A1-A5 (cradle to practical completion): 16.6t CO2e A-C (cradle to grave): 18.5t CO2e Stored CO2: -1.1t CO2e

carbon saving yet mainstream materials: cellulose insulation, GGBS, cement board, silicone render and a foundation approach that reduces the amount of concrete used. There is also some sequestration assumed via carbonation of concrete in the case of the blockwork – included because sequestration figures were included in the EPD for concrete blocks.

PHAI EMBODIED CARBON REPORT

UPGRADE 2B

Transport and construction emissions When transport and construction emissions are considered, the differences between the different build approaches look a little less pronounced, because construction emissions – estimated based on the value of the project, which is assumed not to have changed – are identical in each scenario, at 1.2 tonnes for the walls and ground floor. As mentioned before, the transport data is much less precise than the materials data, given the use of default values in this case. Interestingly, in spite of the fact that many of the materials in the timber frame option are estimated to have travelled far greater distances – such as the cement board, wood fibre sheathing and silicone render – its transport emissions total remains far lower than the base cases – 3.2 tonnes compared to 5.9 tonnes for Base Case 1A and 6.2 tonnes for Base Case 1B. This is for a few reasons: the carbon factors for rigid HGVs assumed locally are far higher than large artics assumed for larger distances, sea freight emissions are very low in relative terms, and heavy materials add considerably to the transport emissions. Use stage In the use stage (Module B), the analysis generally assumed that the building fabric measures would last for the 60 year lifespan of the building set out in the RICS methodology. This rationale is supported by the existence of 60 year design life statements in Agrément certificates for proprietary systems in the case of cement fibre boards and external insulation systems. In the case of the building’s double glazed windows, a 40 year lifespan has been assumed, meaning one replacement is included in module B. Base Case 1A was assumed to have a standard sand/cement 19 mm render, with an estimated 30 year lifespan. The main contribution in the use stage is the air source heat pump. Data for the 6 kW heat pump was derived from an industry association Product Environmental Passport, representing a number of mainstream brands. The PEP assumed a 17 year lifespan for the heat pump, which therefore meant three replacements within the sixty year timeframe, and an embodied carbon total of 8.8 tonnes. The analysis assumed that while the first heat pump would have leakage (in line with CIBSE TM 65) of conventional refrigerants with a high global warming potential, policy on phasing out polluting refrigerants would have kicked in after this point, meaning CO2e emissions for refrigerants were not included in replacement units.

Walls 12.5 mm plaster 215 mm blockwork 8 mm scratch coat 200 mm EPS 450 x 150 mm PUR 10 mm adhesive 20 mm brick slip Floor 75 mm screed 200 mm concrete (50% GGBS) 250 mm EPS150 A1-A3 (materials only, cradle to factory gate): 13.8t CO2e A1-A5 (cradle to practical completion): 19.5t CO2e A-C (cradle to grave): 21.4t CO2e Stored CO2: -1.1t CO2e

There is a remarkable point of comparison here: the cradle to factory (A1-A3) and use stage (B) emissions for the heat pump come in at 8.7 tonnes, compared to 9 tonnes for the external walls and floors of Upgrade 3, the timber frame variant. Heat pumps have an important role to play in decarbonising heating, but – while embodied carbon data on MEP systems generally is in its infancy, clearly work is needed to reduce the embodied carbon of building services. In part this may be down to assuming longer lifespans, and there-

ph+ | phai embodied carbon report insight | 73


PHAI EMBODIED CARBON REPORT

74 | passivehouseplus.ie | issue 38

INSIGHT


INSIGHT

PHAI EMBODIED CARBON REPORT

A–C embodied carbon totals 50 45

600 500

40

Tonnes CO2e

35

400

30

300

25 20

200

15 10

100

5 0

Base Case 1a

Base Case 1b

Embodied tonnes CO2e A–C

Walls Plasterboard and skim 25 mm battens @ 600 centres 12 mm structural airtight board 300 mm cellulose in I-beam 22 mm WF sheathing Battens, counterbattens, 12.5 mm cement fibre board 8 mm proprietary silicone render Floor 75 mm screed 200 mm concrete (50% GGBS) 250 mm EPS150 A1-A3 (materials only, cradle to factory gate): 9.0t CO2e A1-A5 (Cradle to practical completion): 13.4t CO2e A-C (Cradle to grave): 14.6t CO2e Stored CO2: -8.5t CO2e

fore fewer replacements – and there is some evidence of air source heat pumps lasting far longer than 17 years. Another factor which may make a substantial difference is reducing the demand and size of a heat pump, provided it can comfortably meet the building’s actual heat load. The roof build up was common to all variants, consisting of a standard trussed roof with cement fibre slates, and mineral wool insulation at ceiling level. Internal walls consisted of a timber stud walls insu-

Kg CO2e/m2 GIA

UPGRADE 3

Upgrade 1

Upgrade 2a

Upgrade 2b

Upgrade C

0

Embodied Kg CO2e/m2 GIA

lated with mineral wool and finished with plasterboard, and the intermediate floor included a metal web joist, mineral wool insulation, plasterboard beneath and chipboard above. The constant elements – roof, internal walls and intermediate floor, windows and heat pump – add 6.9 tonnes to the module A emissions, 15.3 tonnes to the cradle to grave (A-C) total, and sequester 5.4 tonnes. Further reductions could have been made from the constant elements by a number of measures such as reductions in the number of replacements of heat pumps, choosing a window spec where 60-year lifespan may be reasonably assumed, switching to cellulose insulation for the roof and switching to a thinner calcium sulphate screed. If more radical changes were considered – such as using cellulose insulation in the floor and using ground screws instead of concrete foundations – additional significant reductions could have been achieved. There is also an interesting question of whether improving the fabric to the passive house standard – utilising low carbon materials – would have achieved further reductions, by enabling the use of a smaller heat pump and reducing or potentially removing the need for underfloor heating or other heating emitters. It’s important to note that this analysis was not attempting to produce a like for like comparison between typical cavity wall builds and other approaches. Rather the emphasis was on taking a base case where there has been no particular focus made to reduce embodied carbon use, and to explore what kinds of reductions could be made by switching to relatively mainstream alternatives, supported by certification attesting to their longevity and fitness for use. Further analysis may also involve consideration of other build systems such as insulating concrete formwork, light gauge steel frame, mass timber, poroton blocks, and less mainstream approaches such as hempcrete and strawbale construction. Notwithstanding the health warnings over some of the limitations in this analysis, it demonstrates some of the significant differences in embodied carbon that can result from changes in build specifications at design stage.

Whole building cradle to grave emissions The differences between the various build methods look less pronounced when the whole building calculations are included, rather than the walls and floors only, because the constant elements add significant amounts to the totals. The worst performer, Base Case 1B, totals 43.9 tonnes of CO2e, while the best performer, Upgrade 3, totals 30.8 tonnes. It’s useful to compare the six variants against the embodied carbon targets in RIBA’s revised 2030 Climate Challenge, albeit with the major caveat that not all of the elements of the building have been included in this analysis. The worst performer, Base Case 1B, totals 526 kg CO2e/m2 gross internal area (GIA). In the author’s view, having consulted with building LCA experts, this means it may meet the 2030 target for residential/domestic buildings of 625 kg CO2e/m2, once the missing elements are included. The best performer, Upgrade 3, comes in at 369 kg CO2e/m2, indicating it would likely comfortably surpass the 2030 target. The author speculates that Base Case 1A and Upgrade 1, which respectively total 496 and 492 kg CO2e/m2, would also comfortably meet the target, once the missing elements are included. This begs the question: if a notional house built with business-asusual build specs can potentially meet a forward-reaching embodied carbon target, does the target need tightening?

With thanks to the Passive House Association of Ireland for commissioning this analysis, to Andy Simmonds and Tim Martel of the AECB for conducting the analysis in collaboration with the author and John Morehead, and to Cork City Council’s architect’s department for providing a house type to analyse. Thanks are also due to industry sources who fielded awkward technical questions, including Jane Anderson of Construction LCA, Jess Hrivnak of RIBA, Peter Seymour of EPD consultants EcoReview, Simon Sturgis of Targeting Zero LLP and numerous others.

ph+ | phai embodied carbon report insight | 75


MARKETPLACE

PA S S I V E H O U S E +

Marketplace News Tarimatec eco decking & finishes now available in Ireland

Exhaust air heat pumps prove ideal for social housing — Unipipe

A

vantgard Agents, a leading supplier of porcelain and ceramics, is the new Irish agent for the Tarimatec range of sustainable decking, cladding and internal finishes. Tarimatec is a wood plastic composite (WPC) product composed primarily of plant fibres and recycled plastic. Plasticwood, the brand name of the raw material used by Tarimatec, is composed largely of recovered plant fibres — principally rice shells, a by-product of rice farming. The plastic used in the manufacturing of the product is recycled, meanwhile, and Avantgard Agents told Passive House Plus that some of this is sourced from the recovery of plastic waste from the ocean. Tarimatec is currently in the process of drafting environmental product declarations (EPDs) for its entire product range, and these will be available via Green Building Council España. All of Tarimatec’s products are manufactured at the company’s factory in Valencia, Spain. They are available in two formats, hollowware and solid, and in a wide variety of finishes, colours and sizes. • (above) Tarimatec’s external cladding and decking is a wood composite product made from recovered plant fibres and recycled plastic.

76 | passivehouseplus.ie | issue 38

L

eading renewable heating supplier Unipipe says there has been a large increase in demand for exhaust air heat pumps for new local authority housing schemes. Unlike air source heat pumps, which extract heat from outdoor air, exhaust air heat pumps extract heat from warm stale air that would otherwise be vented from the building. Unipipe supplies NIBE’s F730 exhaust air heat pump, which is suitable for dwellings up to 160 m2 in size, and which provides space heating, hot water, and ventilation all in the one internal unit. “Two years ago we provided exhaust air heat pumps for a scheme of terraced social housing for Dublin City Council, and that proved very successful,” Nick O’Donnell of Unipipe told Passive House Plus. “We’re now providing more F730 units to other local authorities across multiple sites, and we have several more social housing projects as well as apartments underway.” O’Donnell added that exhaust air heat pumps offer a number of advantages for social housing and apartments. For a start, there is no outdoor unit, which makes them ideal for apartments or dwellings with limited garden space and eliminates the risk of vandalism and noise pollution. “All equipment is inside, protected from the elements,” he said. He continued: “The NIBE exhaust air

heat pump is also ideal in smaller dwellings because it saves on space. If you install an air-to-water heat pump, you may still need to put in a separate mechanical heat recovery ventilation system with another controller, but in this case the heat pump, cylinder and ventilation is all integrated in one quiet, fridge-like unit. The NIBE F730 can be connected to underfloor heating or radiators. No electric radiators are required as the inverter compressor output provides up to 4.5 kW. The integrated 180 litre stainless steel cylinder provides plenty of hot water, and weather compensation provides a comfortable, constant indoor temperature. “On one of our recent social housing projects the engineer designed in a very nice detail that allows council staff access to the unit for maintenance from the garden, via a special external door, while on the inside the tenant can easily control their heating, hot water and ventilation from a remote colour screen.” The NIBE F730 is internet and smart grid ready, and it can be remotely monitored via NIBE uplink. It is also possible to integrate the F730 with NIBE solar PV. NIBE has been making and developing exhaust air heat pumps for 40 years as part of its range of heat pumps. • (above) Unipipe’s NIBE F730 exhaust air pump is pitched at smaller dwellings.


PA S S I V E H O U S E +

Ecocem gets €22.5m injection from Bill Gates’s climate fund

MARKETPLACE

Roll out CO2 sensors to slow spread of Covid-19 – NuWave Sensors

T

I

rish low carbon cement maker Ecocem has announced €22.5 million in equity investment from Breakthrough Energy Ventures (BEV) and Breakthrough Energy Ventures-Europe (BEV-E), venture capital funds that are part of Bill Gates’s Breakthrough Energy coalition, which aims to accelerate the global drive towards net zero carbon emissions. “Everyone at Ecocem is very excited at what we can achieve with the support of BEV and BEV-E,” said Donal O’Riain, founder and managing director of Ecocem. “We share the conviction that rapid decarbonisation of cement manufacture is vital for the planet, and that it can be achieved through innovation and the diffusion of new technology. Together we can now meet this challenge with renewed urgency and ambition.” The manufacture of cement generates about seven per cent of global CO2 emissions. Progress in decarbonisation has been limited by the high level of process-related CO2 emissions of cement clinker manufacture. The sector faces high investment and high operating costs from the deployment of carbon capture beyond 2030. Ecocem has long been a pioneer of cement based on ground granulated blastfurnace slag (GGBS), a steel industry by-product, and has processing facilities in Dublin, France and Spain. The company said that the new investment would enable it to bring new “ultra-low carbon” cements to the market over the coming years. “These new products will draw on Ecocem’s deep knowledge in slag-based cements and incorporate new materials and technologies developed by the company.” “Ecocem’s new technologies will enable the global cement industry to reduce its CO2 emissions rapidly and without excessive cost, providing high-performance cements with significantly lower clinker content.” BEV’s board is chaired by Bill Gates and also includes Amazon founder Jeff Bezos, media mogul and former New York mayor Michael Bloomberg, and Virgin Group founder Richard Branson. Another of BEV’s senior members, Carmichael Roberts, welcomed the announcement. “There’s no question the cement and concrete sector is a massive contributor to global carbon emissions and one of the hardest to abate,” he said. “That’s why we’re excited about the work Ecocem has been doing in Europe, and its continued focus, working with the existing cement industry to deploy new technologies and accelerate the adoption of ultra-low carbon cements.” BEV will also nominate a director to Ecocem’s board of directors. •

here has been growing focus in recent weeks on the use of CO2 monitors to help slow the spread of Covid-19, after the government announced at the end of May that it would be supplying the devices to schools across the country. This is a trend that been warmly welcomed by NuWave Sensors, the Dublin and Mayo-based developer of smart air quality sensors. “We know now that poorly ventilated indoor spaces are associated with spread of Covid-19, and a CO2 monitor is a simple, low cost and effective way of monitoring how well a room is ventilated,” Lisa Ainsworth, co-founder and CEO of NuWave Sensors, told Passive House Plus. “While the guidelines from the department are not clear as to whether CO2 monitors in schools will have data loggers, our CaDi CI-100 CO2 sensor has a data logging feature, so users can easily monitor trends in indoor CO2 levels over time. This can also help to identify whether any potential incidents of Covid-19 spread are associated with periods of poor ventilation.” As reported in this issue of Passive House Plus (see News), a number of European jurisdictions have now made the display of CO2 monitors mandatory in indoor spaces that are used by the public, including restaurants and bars. Many of these sensors feature a ‘traffic light’ system that highlights when CO2 levels rise above a particular set point, thus encouraging staff to open windows and doors, or boost ventilation rates. The CaDi CI-100 is a non-dispersive infrared (NDIR) based CO2 monitor that is stable and maintenance free with a measurement range from 0 – 5,000 parts per million. It connects to Wi-Fi and can be monitored using the free smartphone app or web-based dashboard. Users can have multiple devices connected to the same app and multiple users can download and login to the app using the same account. The device provides alerts and recommendations in real time if CO2 levels rise too high. The CaDi monitor is suitable for monitoring an open plan space of up to 325 m2 (3,500 ft2), or one monitor per enclosed space – in a school this would typically mean one monitor is required for each classroom or regularly occupied space. The CaDi also features humidity and temperature sensors, and users can view detailed graphs to analyse CO2 levels by day, week and month. For more see www.nuwavesensors.com. •

(above) Ecocem’s slag grinding plant in Dunkirk, France.

ph+ | marketplace | 77


MARKETPLACE

PA S S I V E H O U S E +

Prodomo offer certified thermal brackets for windows and doors

S

ustainable building product supplier Prodomo Ireland is now supplying Triotherm thermal brackets for windows and doors to the Irish market. Triotherm thermal brackets are made from high density expanded polystyrene and are 100 per cent recyclable. They are certified by the Passive House Institute, approved by IFT Rosenheim, and CE certified too. “Triotherm thermal brackets are desi-

gned to be easy to handle and cut, resistant to ageing, and to simplify thermal detailing around windows and doors. They are highly loading bearing and infinitely extendable,” said Philip Nickol of Prodomo Ireland. “Installing windows and doors has become more challenging over the last decade due to increasing insulation requirements and heavier triple glazed windows and doors. However, for many reasons, traditional

materials for supporting windows and doors are no longer suitable.” Nickol continued: “For example the load bearing capacity of timber isn’t certified, and there is always a risk of rot. Steel brackets will definitely carry the weight of doors and windows, but these have to be specially manufactured, and they create a major thermal bridge. And the common strategy of filling the space underneath the threshold with concrete, once a door is installed, will lead to problems with thermal bridging and moisture transfer. “The U-values of doors and windows can also be substantially degraded by thermal bridging caused by the use of highly heat-conductive materials like concrete or steel. By contrast Triotherm has the same insulating value as mineral wool insulation. It has a high load transfer performance to support all types of windows and doors and simplifies the entire installation process thanks to the wide variety of available dimensions and accessories, like waterproof tanking when used beneath door thresholds.” For more information see www. prodomo.ie. • (above) Triotherm thermal brackets are designed to support windows and doors while eliminating thermal bridging.

Grant heat pumps at centre of NI energy transition project

L

eading heating technology manufacturer Grant will be supporting Ulster University and the Northern Ireland Housing Executive (NIHE) in their RULET – Rural-Led Energy Transition – initiative, aimed at reducing or eliminating the risk of low-income households being left behind in the transition to clean, smart, integrated energy systems. The RULET initiative is part of the SPIRE 2 (Storage Platform for the Integration of Renewable Energy) project which is a €6.7m EU-funded Interreg VA, cross border project that aims to evaluate, develop, and facilitate the wide-scale deployment of consumer-owned energy storage technologies, to operate profitably in the changing energy markets in Ireland and the UK. Led by the Ulster University and the NIHE, RULET is focused on making the full benefits of smart energy technology available to the most vulnerable households in the western counties of Northern Ireland, a wind energy hotspot. This includes the installation of the Grant hybrid heat pump system which has been specially designed for social housing. Commenting on the company’s involvement in the initiative Barry Gorman, natio-

78 | passivehouseplus.ie | issue 38

nal renewables sales manager at Grant said: “We are delighted to be supporting the Ulster University and [the] Northern Ireland Housing Executive in this initiative and helping to advance the deployment of renewables throughout Ireland and the UK. Our hybrid heat pump system allows a 6 kW heat pump to run in tandem with an existing boiler installation. Following basic energy efficiency upgrades carried out by the Northern Ireland Housing Executive, the hybrid system will run at high efficiency using wind energy stored overnight and will help to significantly reduce fossil fuel consumption and carbon emissions.” The first part of the project aims to enable people to avail of agile tariffs by running the Grant Aerona3 R32 6 kW air-to-water heat pumps to charge Sunamp heat batteries. When wind energy is available on the system, NIHE tenants will be able to avail of exceptionally low home heating prices. Grant said that all four models within the R32 range, 6 kW, 10 kW, 13 kW and 17 kW, have an ErP rating of A+++ and a seasonal coefficient of performance of up to 5.4, making them ideal for compliance with Part L

and NZEB. The R32 refrigerant used also has a lower global warming potential than typical heat pump refrigerants. “Even if external temperatures were to drop as low as -20C, the heat pump’s output will modulate up or down depending on the exact climate conditions to ensure ultimate energy efficiency for the property,” according to Grant. Visit www.grant.eu for more information on Grant’s range of innovative heating solutions. •

(above) The Grant Aerona3 R32 air-to-water heat pump.


PA S S I V E H O U S E +

PARTEL LAUNCHES NEW EUROCLASS A2 FIRE-RATED VAPOUR CONTROL SYSTEM

MARKETPLACE

Wicklow company makes eco-board from food packaging

P

artel’s newly launched Euroclass A2 Izoperm Plus vapour control system, designed for internal applications in energy efficient buildings, has become the first fire-rated solution in this class developed in Ireland. The system is comprised of Izoperm Plus FR vapour control layer plus Echoseal Alu FR adhesive tape. As a passive fire protection solution, the system is designed to safeguard critical structural components, and to slow and confine a fire once it has started, providing “outstanding fire safety and smoke protection for both occupants and construction assets”, according to Partel. The system was tested to and successfully received the Euroclass Class A2-s1, dz0 standard in accordance with EN 13501-1, making it ideal for taller buildings. “High-rise structures, by their very design, pose particular fire-safety issues. As a result, building codes for high rises emphasise fire-resistant construction. Our integrated technical solution was explicitly built in response to evolving building requirements to be Class A2-s1, dz0 fire-rated — facilitating designers, architects, and building professionals to achieve modern resilient buildings,” said Hugh Whiriskey, founder and technical director of Partel. Partel said that its high-performance membrane and tape uses an innovative technology based on lacquered aluminium laminated with strong glass fibre. Both aluminium and glass fibre are non-combustible, ensuring excellent fire resistance, the company said, and this unique composition guarantees superior structural integrity and durability alongside a high mechanical resistance and maximum airtightness. Izoperm Plus FR acts as an air and vapour control layer, preventing condensation and improving energy efficiency in building assemblies. It is suitable for all construction types, especially mid and high-rise public buildings such as offices, hospitals, schools, and shopping centres where building codes recommend a higher level of fire safety. The system has been extensively tested in accordance with EN 13823 (single burning item test) and has successfully received the Class A2-s1-d0 standard in accordance with EN 13501-1. In this case, s1 indicates the highest performance category for minimum smoke production if ignited by a fire, and d0 represents the highest performance category with regards to the potential for hot droplet/ particle production. “The system comes with an unmatched 20-year warranty and uncompromising quality from Partel,” Hugh Whiriskey said. For more information see www.partel.ie. • (above) Partel’s Izoperm Plus vapour control system has achieved a Euroclass A2 fire rating.

T

he construction and demolition sector is among the top waste producing industries in Ireland, generating close to 1.5 million tonnes per year, excluding soil and stone. While for many years sustainability in buildings has focused on energy use, it is now clear that we must reduce our resource use in other areas too, moving from the linear model of consumption — take, make, waste — to a circular one, in line with the government’s ‘Waste Action Plan for a Circular Economy’. One business doing just that is Wicklow-based Acoustic Materials, which for six years has been working to create sustainable and circular construction products. The company’s focus has been on materials that improve building acoustics, but the use of its products extends far beyond this. One of the company’s products, AM Ecoboard, uses food packaging material that has been deemed non-recyclable, because of the difficulty of separating its components, to create a construction board that can be used in place of OSB, plywood, and even plasterboard. Though to date the company has been focused on its use as a high-performing soundproofing board, AM Ecoboard is now being certified for use as a roofing and racking board too. “Though made of post-consumer waste, AM Ecoboard is not a compromise on traditional building boards. In many ways it is a superior material,” says Stephen Stratton, managing director at Acoustic Materials. “Sometimes when we tell people what we do, you can see them wrinkling their nose, but once we put the board in their hands their attitude changes. “Ecoboard has an impressive list of attributes. It is fire rated, sound rated, mould and mildew resistant, and has extreme impact resistance. It is also air and vapour tight. Most importantly for the manufacturers, it is formaldehyde free. Ecoboard doesn’t just help the natural environment, it contributes to a healthy indoor environment too.” As Ecoboard is designed to be an integral part of a building’s structure, it offers an opportunity to lengthen the life cycle of a material, food packaging, that is designed for short term use. Every 100 m2 of Ecoboard diverts 510 kg of paper and 340 kg of plastic from landfill, according to Acoustic Materials. Ecoboard can also be processed into new boards with no loss of performance, the company said, adding that it will happily take back any Ecoboard in buildings destined for renovation or demolition. • (above) AM Ecoboard is produced from recycled food packaging.

ph+ | marketplace | 79


MARKETPLACE

PA S S I V E H O U S E +

Better for You, Better for Nature. Sustainable Air to Water Heat Pumps

Passive sills provide superior window sills, over sills and decorative mouldings to the construction and external insulation industries.

• • • •

Passive Sills can be retrofitted to existing window sills making them the ideal choice for external insulation contractors, or can be used in new build and can be fitted to the most awkward windows.

• • • •

ROI: 021 201 9056 UK: +44 203 808 5149 E: info@passivesills.com

Contact Donal Reilly, Waterford Stanley for more information 00353 (0)87 227 1686

donalreilly@waterfordstanley.com

Eliminate Cold Bridging Lightweight Easy to install Available up to 3.6m in length Traditional appearance Can be painted For all types of construction – ICF, timber frame, block build, external insulation Easy to repair

waterfordstanley.com

save your energy nea are independent energy consultants, fully qualified and registered BER assessors for both Domestic and Non-Domestic BER assessments. Operating nationwide, nea are a one-stop shop for:

BERs Air Tightness Testing Sound Testing Ventilation Testing Part L Compliance

BERs

Domestic/Commercial BERs Sale/Rental/New Build Properties SEAI Grant Applications

Air Tightness Testing

Air Permeability Testing for New Builds Draft Detection Diagnostics for Existing Buildings NSAI Registered

Sound Testing Part E Compliance Airborne Testing Impact Testing

Part L Compliance

Preliminary BER Analysis Insulation, Ventilation and Heating System Specification One off self builds to major developments

Ventilation Validation Testing Part F Compliance

Training

Registered QQI Training for becoming a BER Assessor Training for building professionals on using and understanding BER Software

Please visit nea.ie to find out more or arrange an appointment.

T: 096 31622 info@nea.ie 80 | passivehouseplus.ie | issue 38


PA S S I V E H O U S E +

MARKETPLACE

Prestige Aluclad: bespoke passive glazing can be competitive

A

rchitects and self-builders who are designing bespoke dwellings often struggle to find bespoke glazing products that match their ideal design, but leading supplier Prestige Aluclad says consumers can find custom window and door solutions at competitive prices if they turn to specialist manufacturers. Prestige Aluclad is developing a reputation as a leading supplier of bespoke glazing solutions in a market that is often geared toward standardised sizes and designs. The company was launched five years ago and has a particular focus on glazing for passive and NZEB dwellings. It is spearheaded by David Mulholland and Declan Loy, who have almost 25 years’ experience in the aluclad business. “We used to have to tell people that they couldn’t have certain glazing options, which they or their architect might have specified, because the big manufacturers weren’t interested in doing bespoke manufacturing. But that has all changed now,” Loy said. Prestige Aluclad now works with a

number of specialist factories in Europe, making windows and doors to order. “People for example would have asked me for specific designs for front doors, and we would have had to say ‘no, we can’t do that’, because the manufacturers didn’t make them,” Loy said. “That was always frustrating for me. But now we are working with two factories that can make bespoke front doors to any design.” In a similar vein, Prestige Aluclad can now offer sliding doors up to three metres high, another product that can be difficult to source from standard window catalogues. The company also offers three metre sliders and sliding doors up to six metres wide. Loy continued: “We can also now supply large picture windows in aluclad, something many people aren’t even aware is available on the market. The largest picture window we have done has one pane of glass that is 3.2 by 2.8 metres. Not many suppliers can do that size. Instead, they will say you have to split the window up and put mullions in — but mullions kill

the view, and kill the energy performance too.” Loy continued: “Of course when you install big panes of glass, you also need to think about ventilation. Customers may be advised to put in transoms, but a transom also ruins the view and affects thermal performance. We can supply secure, floor-to-ceiling tilt and turn windows up to 2.6 metres high, with an overall U-value of 0.7 — and the pricing is competitive. We can also do large tilt-and-turn windows for upper floors with a glass balustrade for safety.” Loy said the final thing the company can now offer is glass-to-glass corner windows, which offer a much better U-value than when a corner post is required. “And we can offer sliding doors that can slide into the glass corner,” he added. “What differentiates us on the market is that we’re giving architects and homeowners exactly what they want through manufacturing bespoke solutions, rather than just offering standard sizes and designs from a catalogue.” “All of those things are what excited me about starting up the Prestige Aluclad brand. We are the number one bespoke window supplier in Ireland now, and there’s not a lot we can’t do or make.” Loy added that while some of the bespoke solutions that the company specialises in are available on the market in aluminium, few are available in timber aluclad, a product that offers a “lower carbon footprint, better airtightness and better thermal performance all around.” For more see www.prestigealuclad.ie. • (above) Previous Prestige Aluclad projects include Simply Architecture’s award-winning passive Steep Wedge House in Douglas, Co. Cork.

Beam launch new app for easy heat recovery control

T

he new Beam VentSmart app for the Axco Counterflow range of MVHR units is now available. Beam said that the app has been designed to make control of its heat recovery ventilation systems as easy and straightforward as possible. The VentSmart app is compatible with wi-fi enabled Beam Axco heat recovery ventilation systems and is free to download for all Apple and Android users. With a few simple steps, the user can create an account and connect to their heat recovery ventilation system. With a user-friendly interface, the app makes it easy for users to connect to and monitor their system from both inside and outside the home. The new Aura-T Smart touchscreen control panel also connects wirelessly to the heat recovery system, allowing the user to adjust fan speed and settings, receive filter change alerts, boost switch function and more. For further information, visit www.beamcentralsystems.com/Vent-Smart-AppProduct-Info. •

ph+ | marketplace | 81


MARKETPLACE

PA S S I V E H O U S E +

Ecocel on site with 56 homes in Cork I

rish cellulose insulation manufacturer Ecocel is currently on site completing the installation of its cellulose insulation to a new social housing development in County Cork. Beechwood, Clonakilty is a scheme of 56 dwellings, incorporating new houses plus apartments in a converted stone building. The installation of 330 mm of Ecocel in the roof of each dwelling is achieving a U-value of 0.11, John Egan of Ecocel told Passive House Plus. “Besides thermal performance, Ecocel also offers a number of other key benefits including excellent fire protection and a very low carbon footprint. “And because it is blown in, installation is also highly efficient. We started on a Tuesday morning and by Friday morning we had completed 16 houses, insulating over 900 m2 of floor area.” Ecocel is manufactured in Cork City from recycled newspaper. “Because the material is blown, rather than laid out, it fills every nook and cranny and ensures a quality installation that completely fills the space being insulated,” Egan said.

“Attic insulation is often overlooked compared to more complex building fabric solutions, but it is the simplest, most effective way to save energy in a dwelling. A U-value of 0.11 should be the minimum requirement. Heat rises, so zero heat loss through the attic should be our goal. “People sometimes think they can simply roll out attic insulation themselves, but quality expert installation is important here too to ensure it functions effectively to achieve zero heat loss.” The dwellings at Beechwood are all constructed from cavity block walls and built to the NZEB standard, with air source heat pumps as the main form of space heating. Egan added: “We also think it’s important that the energy performance of houses is tested after five years and ten years. At the moment we are relying on predictions of energy performance, we are not testing real time energy performance. We believe that the thermal performance of Ecocel improves over time as the material settles and becomes more dense.”•

Ecological seminar tackles embodied carbon ‘blind spot’ E

82 | passivehouseplus.ie | issue 38

‘NZEB pandemic performance’, in which he stressed the necessity of optimising comfort and internal air quality now that remote working has become the norm. Finally, Niall Crosson, group technical manager with Ecological, built on this by describing how thermal comfort was achieved on his own passive house through the use of sustainable materials, airtightness and a well thought out ventilation strategy. “When one considers that embodied carbon will be responsible for almost half of total new construction emissions between now and 2050, there is no time to waste in addressing our upfront carbon emissions through better design and the use of more sustainable building materials,” said Crosson. Find out more at www.ecologicalbuildingsystems.com. • Photo by Gabrielle Morehead

cological Building Systems recently hosted a series of thought-provoking presentations on the topic of going beyond NZEB and addressing the carbon blind spot of the construction industry: embodied carbon. With over 200 in attendance for this virtual seminar, delegates were treated to six informative presentations delivered by a panel of leading experts from different sectors of industry. The ‘2NZEB & Beyond’ seminar aimed to raise awareness of to how to achieve NZEB compliance, and more importantly, to look beyond this to address the environmental impact of the materials we choose to build with. With a growing emphasis on carbon emissions, there is a need to not only consider how much carbon is used in manufacturing products, but also to think about what happens once they have reached their end of life. The first speaker was Antonella Uras from SEAI with her presentation ‘NZEB in new build and retrofit’. Antonella outlined some interesting technical developments ahead for DEAP energy assessment regarding new cooling and overheating calculations. This could increase the demand for more widespread adoption of thermal insulation with a higher heat storage capacity, such as wood fibre insulation, a point which was complimented by Stephen Barrett of the IGBC in his presentation, ‘Burping, driving, and counting the true carbon impacts of our material choices’. Stephen highlighted how using one square metre of wood fibre insulation can offset the equivalent of 860 km of driving, whereas one square metre of PIR can contribute the equivalent of 1,188 km. Michael O’Brien of the WWETB summarised the development of NZEB courses to address the future needs of the industry and of the outstanding work being done to upskill trades, which are a vital cog in the wheel if Ireland is to meet 500,000 BER housing upgrades to B2 standards by 2030. Meanwhile, John Morehead of Wain Morehead Architects delivered a detailed and thought-provoking presentation,

(above) West Cork passive house designed by John Morehead, who will speak at the event.


PA S S I V E H O U S E +

Munster Joinery publishes first Irish window EPD

MARKETPLACE

New app for remote control of Nilan Compact P N

M

unster Joinery has published the first environmental product declaration (EPD) for a window under the Irish EPD system. The EPD was published for the company’s Passiv uPVC window and is available to view on the Irish Green Building Council’s EPD database. “This EPD has allowed Munster Joinery to measure its performance and set goals in regard to sustainability while demonstrating our commitment to reducing carbon emissions,” said Marlene O’Mahony, quality manager with Munster Joinery. “We expect to publish EPDs for our other product ranges in the coming months.” An EPD is a standardised report containing data on the environmental impacts of a product or material over its lifetime. This data provides construction industry professionals with a transparent source of information, allowing the comparison of different products under a common set of environmental performance indicators. The EPD is based on data generated by a life cycle assessment (LCA), which can measure the sustainability of the product across various stages – production, installation, use and end of life. The production stage assesses the impacts of raw material supply, transport and manufacturing. Seven different impact categories are used: climate change, depletion of abiotic resources (both fossil fuel and elemental), ozone depletion, photochemical oxidation, acidification of land and water, and eutrophication. As the availability of EPDs for construction products increases, specifiers will be able to access quantified environmental information detailing the impacts of materials in buildings. This will allow more informed decisions in procurement. “Munster Joinery aim to be at the forefront of this drive to make accurate, unbiased sustainability data available to the market,” O’Mahony said. “This reflects our wider sustainability policy. All our product ranges meet NZEB requirements as a minimum and eight product lines are certified by the Passive House Institute in Germany. We aim to make sustainability, carbon neutrality and energy efficiency accessible to the built environment. “Our operations are tailored to minimise the use of energy and water, use materials that are environmentally friendly, use recycled materials wherever possible, minimise waste and continually reduce emissions. “Much of our energy needs are met by two wind turbines with an electrical output of 4.2 megawatts. A biomass combined heat and power (CHP) plant with a capability of 12 MW thermal and 3 MW electrical also contributes significant amounts of green energy to the plant.” •

ilan has developed a new app that allows users to control their ventilation system and heat pump directly from their mobile phone. The feature now comes as standard on all of the company’s popular Compact P combined heating and ventilation systems. “The app is intuitive, easy and secure to use, and allows the user to easily set room and water temperatures,” Maurice Falvey of Nilan Ireland told Passive House Plus. Multiple ventilation units can be connected via the same app, while the app also allows for multiple users to have control over the same system. “This new app will give the user remote access to the Compact P unit as standard. It’s just as good as if you were using the touch screen display on the machine itself,” Falvey said. He explained that once the ventilation system is connected to the internet via a Nilan gateway, the system can be remotely controlled using the Nilan user app, which can be downloaded for free for both Android and Apple phones from the relevant app stores. Using a LAN connector, users can connect the gateway to the Modbus of the Compact P. This creates a secure cloud connection between the unit and the smartphone. The app allows users to both monitor the operation of the system and to adjust user settings, such as desired temperature, desired fan step level and humidity control. Users can also see how many days are left until the next filter change is required, and the user is notified when it is time to change the filter. Users can also view historical data and trends curves over time, such as room temperature and humidity. “From a service point of view, with the homeowner’s permission, the system can also give us access to diagnose faults remotely, or to view historical sensor data and see if there are any issues with the performance of the machine. It allows us to make sure it is running smoothly, and as efficiently as possible,” Falvey said. He continued: “This form of remote access makes the Compact P ideal for holiday homeowners, who want to control their heating and ventilation system remotely, or for social housing providers or apartment managers who need to look after a large number of heating and ventilation systems. It’s a fully-fledged remote service tool for us.” The Nilan Compact P is one of the most popular heating and ventilation units in Irish passive houses. For more information see www. nilanireland.ie. • (below) The Nilan Compact P now comes with smartphone control as standard.

ph+ | marketplace | 83


MARKETPLACE

PA S S I V E H O U S E +

Enduring beauty, sustainably

from AvantGard Tarimatec's European-manufactured solutions for cladding, fit out and decking show that avant garde levels of sustainability don't have to mean compromising. Th That by integrating recovered plant fibres with recycled plastic - while simultaneously cleaning the oceans - Tarimatec has produced something extraordinary - a product which shows that being deep green can enhance the design of a building, and stand the test of time. For more information please contact mark@avantgard.ie 84 | passivehouseplus.ie | issue 38


PA S S I V E H O U S E +

MARKETPLACE

LIDAN COMPLETES MODULAR BUILDINGS FOR LOCAL AUTHORITIES L

eading offsite timber construction specialist Lidan Designs recently completed a number of modular, low embodied carbon, nearly zero energy buildings (NZEBs) for public authorities. Dan O’Brien of Lidan Designs told Passive House Plus that the company’s build method makes it uniquely placed to deliver modular NZEBs that can be craned into place, fully finished, on delivery. “We recently completed a 30 m2 extension to a house for Longford County Council which we delivered fully finished. Site works were progressing at the same time that we were building the structure in our factory, and when the building was finished we craned it over the house and connected it to the existing dwelling, and then we finished it the following day. Build time was just one week. Our method minimises time on site and disruption to the occupants.” He continued: “Our buildings are constructed from timber frame with natural insulation, making them among the most sustainable buildings in Ireland, with extremely low embodied carbon values.” Lidan recently delivered four separate public amenity buildings for parks managed by Fingal County Council, including Newbridge Demesne outside Donabate. The projects included the demolition and removal of existing structures from the four sites, plus offsite construction and delivery of the buildings, each of which contains five universal access WCs, a ranger’s room, a service room, and a Changing Places facility. The buildings were constructed to meet the domestic version of Part L (NZEB for dwellings), and each includes a solar photovoltaic array. They also feature handmade, bespoke Delabie anti-vandal fittings, interior toughened walls, anti-slip flooring, and a vandalproof standing seam roof. They are clad in a mix of western red

cedar, standing seam metal and traditional plaster, all of which were hand-applied in the factory by Lidan Designs. They are also equipped with non-touch sensor taps, with built-in heating mixture temperature control valves. The buildings were sunk into the ground, which required extra groundworks, but ensured no ramps are needed for access. They feature bespoke, handmade reinforced aluminium doors. The public amenity buildings were built and delivered to a six-week schedule. For more information see www.lidandesigns.com. • (below) Lidan recently completed a number of modular low embodied carbon buildings for local authorities, including public amenity buildings for Fingal County Council, and a housing extension for Longford County Council that was craned into place.

Cem-Rock offers best-in-class fire & eco credentials – Greenspan

L

eading Limerick and Birmingham-based sustainable building product supplier Greenspan has added a floor substructure board to its Cem-Rock range of magnesium oxide (MgO) sheathing boards. “Cem-Rock is mainly geared to be used as a sheathing board for larger buildings, and for mid and high-rise construction,” Mike Cregan, managing director of Greenspan, told Passive House Plus. “We find it’s very popular because of its excellent fire performance and because of its tremendous structural and sustainability credentials. It also has excellent pull out resistance and racking strength, making it ideal for use on timber frame construction.” Designed as an alternative to traditional fibre cement or OSB/plywood boards, Greenspan launched Cem-Rock in 2013. Cregan said that the board’s “fire, moisture, mould and mildew resistance properties far outweigh any competing products like plywood or OSB sheathing” and that its performance is unaffected by environmental exposure during construction. The company has developed different

variations of the product to be used as exterior sheathing boards, external insulation substrate boards, and rainscreen backer boards. The newest iteration is Cem-Rock Floor. “Cem-Rock Floor has structural and bending characteristics similar to plywood, and Cem-Rock Floor has been tested for its load bearing capabilities making it suitable for all classes of buildings,” Cregan added. Cem-Rock is produced from magnesium oxide, a white hygroscopic solid mineral, together with binders such as perlite and wood dust. The material is inert and fully recyclable. It is manufactured using a cold process that is powered entirely on electricity, so can be fully powered by renewables, and requires no firing or autoclaving, thus minimising carbon emissions. “Cem-Rock Floor also offers best-in-class fire performance,” Cregan said, “making it a popular choice for large buildings such as apartments, commercial, student accommodation and high rise where fire performance is critical”. It has achieved Euroclass A1 non-combustibility rating according to

BS EN 13501, and Cem-Rock achieves more than two hours of fire resistance on wall partitions according to BS EN 476 parts 20 and 22. Cem-Rock has also recently become the first Irish brand of MgO boards to enter the US market. For more information see www. cemrock.ie. •

(above) Cem-Rock Floor, the newest addition to the Cem-Rock magnesium oxide board range.

ph+ | marketplace | 85


T O BY C A M B R AY

COLUMN

On the 3D printing of buildings Building physics expert Toby Cambray finds himself unconvinced by the merits of a new home in the Netherlands that has been 3D printed with concrete.

T

o the already long list of unfashionable opinions which I have put forward, I need to add the following: when it comes to 3D printing, I can’t see what all the fuss is about. Sure, it’s a useful means of making prototypes, and the small number of one-off products or parts that need very little strength – but there seems to be a distinctly finite number of those. 3D printers mostly seem to churn out little toy boats more likely to pollute our oceans than sail on them. Some argue that 3D printers are inexpensive enough to represent a democratisation of the manufacturing process, but I don’t buy it. There is still a skill threshold to reach in the digital design stage, time which one could spend learning how to use a metal working lathe, hobby versions of which aren’t much more money than a half decent 3D printer. Or think of the stunning architectural models that have been made with little

Proper sustainable building is all about the boring stuff.

more than a craft knife. So, while 3D printing is an interesting tool to add to our collective arsenal, the popular obsession with it is baffling to me. You will be therefore unsurprised to read that I have reservations when it comes to the recent flurry of attention around 3D printed buildings. The one doing the rounds on the socials at the time of writing is the Dutch “boulder house” featured in the Guardian (30 April 2021). This detached house is the latest in a string of prototypes and is designed to resemble a boulder. Exactly which boulder served as a model has not been disclosed. I understand that the process is still in development, but if this is the sort of architectural expression we can expect to be unlocked, I am unmoved. Even if more ‘interesting’ shapes become possible, are they a good idea? Frankly, assuming for a moment that such forms are so essential to architectural expression, all this is possible with more boring techniques. Then there is the subject of form versus function in passive

86 | passivehouseplus.ie | issue 38

The recently completed ‘boulder house’ in Eindhoven.

buildings, which I won’t rehash here. This is Passive House Plus after all, so we turn next to the thermal performance. Those involved are coy about the exact performance, and though I’d be delighted to be proven wrong I doubt that the energy performance is being measured. It’s difficult to find out exactly how the walls work in the Dutch example, but we can see in Matt Risenger’s recent video (‘Is this the future of Construction? 3D Concrete Printed Homes’, YouTube, 4 May 2021), that we have two leaves separated by a zigzagging ‘core’ like an extruded truss-joist. The window reveals are formed by simply continuing the leaves from inside to out. I therefore raised an eyebrow when the engineer claimed the construction to be ‘thermal bridge free’. In other words, as far as I can tell, to actually add insulation to any of these structures, you’d have to stick it on the outside afterwards (and clad to taste), which seems to defeat the object somewhat. Airtightness wise, OK it is monolithic but it’s at junctions (windows, floor, services) where one finds leaks, so I’m unconvinced the method of construction is inherently airtight. As printed, the internal walls are rough, but Matt Risenger assures us it’s not a bug, it’s a feature. Anyhow, good luck keeping all those crevices clean. We should also consider the claim that this technology speeds up construction. I’m willing to accept it might save some time on the superstructure compared to standard masonry, but anyone that has experienced a build from beginning to end knows that the superstructure is far from the most time-consuming element – it’s the groundworks, services, fixtures and fittings and finishing that take the real time.

Finally, there is the issue of embodied carbon. Most of the examples I’ve seen are some sort of very clever concrete, though an earth-based example has also been finished (with only a tiny bit of ‘binder’). The builders attempt to justify the Dutch example by observing that we must use less concrete, and the boulder house uses less. I’ll go out on a limb and say maybe – stay with me – you might use less concrete if you didn’t build the entire house out of it. The waste of resources is perhaps the most frustrating thing – not just the concrete but the human effort. I’ve no doubt that it was a great technical achievement to develop this technology, but it has the feel of a solution looking for a problem. One of those ideas that look great in the sketch book and are sexy enough to get some cash thrown at them, but aren’t really moving us forwards. In contrast, proper sustainable building is all about a solid strategy, the fine detail and quality of execution – some might say, the boring stuff. If you’re reading this magazine, you probably know all this and spend your time worrying about precisely which type of airtightness tape is best to join material A to material B, rather than whether we can equip a drone with a tube of silicone. And I salute you and your quiet dedication to getting on with delivering sustainable buildings. n

Toby Cambray is a founding director at Greengauge and leads the building physics team. He is an engineer intrigued by how buildings work and how they fail, and uses a variety of methods to understand these processes.


ph+ | editor’s letter | 91


Daikin’s streamer technology inactivates more than 99.9% of the novel coronavirus (SARS-CoV-2) after 3 hours*

Daikin Electrostatic HEPA Air Purifier Pure air and peace of mind thanks to ECARF certification and patented flash streamer technology

Available at all Allied Merchants Buying Association members *Source: “Study report on the inactivation effect of plasma ion generator (Daikin Streamer) on SARS-CoV-2”

88 | passivehouseplus.ie | Issue 21 Department of Veterinary Medicine, Microbiology Course, Okayama University of Science by Shigeru Morikawa,


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.