Condensing Units n Reliable and efficient Copeland Semi-Hermetic Compressors n Supplied c/w HP/LP, Crankcase Heater, Oil Seperator, Liquid Receiver, Liquid Line Drier & Sightglass, Suction Accumulator, Electrical box fully wired c/w Main Isolator in a ColorBond housing n Twin fan models include fan cycling pressure switch n All condenser coils supplied with “Patton Coat” fin and coil protective coating

1.5

SEMI-HERMETIC 150 - 400

4

hp

CAPACITY (Watts) @ 32°C Ambient MODEL

Nom. Refrig. E vaporating Temp °C hp -35 -30 -25 -20 -15 -10 -5 0 5 10

PSC150

1.5 R134a

-

-

-

1190 1560 2010 2520 3080 3780 4520

R404A 950 1260 1580 2060 2540 3195 3850 4550 5300

PSC200

2.0 R134a

-

-

-

1750 2275 2900 3615 4430 5330 6330

R404A 1210 1730 2210 2900 3700 4650 5700 6700 7800

PSC300

3.0 R134a

-

-

-

-

-

2315 3000 3800 4700 5700 6800 8000

R404A 1670 2310 3100 4150 5300 6600 7950 9300 10800 -

PSC400

4.0 R134a

-

-

-

3330 4340 5490 6790 8235 9825 11555

R404A 2270 3230 4370 5730 7350 9240 11390 13385 16340 -

www.pattonnz.com

PATTONPAK PSC SEMI-HERMETIC 150 - 400

PSC


DIMENSIONS

PSC200 PSC300 PSC400

PSC150

NTS (mm)

TECHNICAL DATA COMPRESSOR

CONDENSER RECEIVER CONNECTIONS

MODEL

Fan Motor(s) NOM. hp

MODEL

VOLTAGE

RLA LRA Amps Amps

Model

Airflow l/sec

No. (1)

Tot Tot Watts Amps

Capacity (kg) (2)

Noise Level (dbA) Suction Liquid (3)

Wt (kg)

PSC150

1.5

DKSJ15X-EWL

380-420/3/50

3.3

20.4

CPK200

1007 1 x 350

145

0.7

3.7

3/4”

3/8”

58

92

PSC200

2.0

DLE20X-EWL

380-420/3/50

5.7

37.6

CPK350

1933 2 x 350

290

1.4

6.2

7/8”

1/2”

59

170

PSC300

3.0

DLF30X-EWL

380-420/3/50

7.2

53.0

CPK450

1859 2 x 350

290

1.4

6.2

7/8”

1/2”

61

173

PSC400

4.0

DLL40X-EWL

380-420/3/50

9.3

68.5

CPK500

1787 2 x 350

290

1.4

6.2

1-1/8”

1/2”

61

180

NOTES: 1. All fans 220-240/1/50 2. R404A pump down capacity shown @ 80% full for 32°C liquid temperature

3. All noise level ratings are “free field” based at a distance of 3.0 mtrs from source and are given as a guide only. 4. Electrically complies to AS/NZS 60335.2.89 : 2002 + A1 - A3 (selected clauses)

www.pattonnz.com

The company reserves the right to make specification changes without notice. 03/07/14


Condensing Units n Reliable and efficient Copeland Semi-Hermetic Compressors n Supplied c/w HP/LP, Crankcase Heater, Oil Seperator, Liquid Receiver, Liquid Line Drier & Sightglass, Suction Accumulator, Electrical box fully wired c/w Main Isolator in a ColorBond housing n Twin fan models include fan cycling pressure switch n All condenser coils supplied with “Patton Coat” fin and coil protective coating

5

SEMI-HERMETIC 500 - 2000

20 hp

CAPACITY (Watts) @ 32°C Ambient MODEL

Nom. Refrig. E vaporating Temp °C hp -40 -35 -30 -25 -20 -15 -10 -5 0 5 10

PSC500

5.0

PSC700

7.0 R404A 2975 3775 5160 6745 8475 10560 12990 15300 18350 22200 -

R404A

1560

2380

3410

4620

6050

7730

9690

11950

14600

17600

-

PSC750 7.5 R134a - - - - 5555 6870 8585 10705 13210 16195 19400

R404A 3595 5015 6605 8285 10365 12605 15345 18330 22000 26300 -

PSC800 8.0 R134a - - - - 6250 7930 10005 12650 15640 19110 22990

R404A 3700 5310 7245 9265 11660 14565 17510 2100 25500 30600 -

PSC1000 10.0 R134a - - - - 7240 9600 12350 15470 19225 23450 28190

R404A

5970 6690 8660 11165 14040 17320 21005 25200 30500 36450

-

PSC1500 15.0 R134a - - - - 10180 13630 16630 20605 25215 30360 36440

R404A

8485 9500 11900 15160 18880 22985 27500 32925 38500 45700

-

PSC2000 20.0 R134a - - - - 12000 15100 18400 23840 28760 34650 39850

www.pattonnz.com

R404A

9760 10950 14000 17500 21050 26000 31050 36900 41100 50050

-

PATTONPAK PSC SEMI-HERMETIC 500 - 2000

PSC


DIMENSIONS

PSC500 PSC700 PSC750

PSC800 PSC1000 PSC1500 PSC2000

NTS (mm)

TECHNICAL DATA COMPRESSOR

CONDENSER RECEIVER CONNECTIONS

MODEL

Fan Motor(s) NOM. hp

MODEL

VOLTAGE

RLA LRA Amps Amps

Model

Airflow l/sec

No. (1)

Tot Tot Watts Amps

Capacity (kg) (2)

Noise Level (dbA) Suction Liquid (3)

Wt (kg)

PSC500

5.0

D2DD50X-AWM

380-420/3/50

10.3

55.0

CPK650

4320 2 x 500 1090

4.8

8.8

1-1/8”

5/8”

62

205

PSC700

7.0

D2DL75X-AWM

380-420/3/50

13.8

70.0

CPK800

3927 2 x 500 1090

4.8

10.4

1-3/8”

5/8”

63

270

PSC750

7.5

D2DB75X-AWM

380-420/3/50

16.1

70.0

CPK900

3750 2 x 500 1090

4.8

10.4

1-3/8” 5/8” 63 290

PSC800

8.0

D3DA75X-AWM

380-420/3/50

17.5 106.0 CPK1200

4770 2 x 630 1120

2.1

10.4

1-3/8”

5/8”

64

290

PSC1000

10.0 D3DC100X-AWM

380-420/3/50

21.5 121.0 CPK1300

4830 2 x 630 1680

2.9

10.4

1-3/8”

5/8”

65

350

PSC1500

15.0 D3DS150X-AWM

380-420/3/50

29.0 129.0 CPK1500

5393 2 x 630 1680

2.9

20.0

1-5/8”

7/8”

66

365

PSC2000

20.0 D4DA200X-AWM

380-420/3/50

32.5 175.0 CPK2050

6629 2 x 630 2500

5.0

20.0

1-5/8”

7/8”

69

460

NOTES: 1. 500mm Fans - 220-240/1/50 630mm Fans - 380-420/3/50

3. All noise level ratings are “free field” based at a distance of 3.0 mtrs from source and are given as a guide only.

2. R404A pump down capacity shown @ 80% full for 32°C liquid temperature

4. Electrically complies to AS/NZS 60335.2.89 : 2002 + A1 - A3 (selected clauses)