Factors%20affecting%20the%20inactivation%20of%20micro organisms

Page 1

Journal of Applied Microbiology 2005, 99, 460–470

doi:10.1111/j.1365-2672.2005.02641.x

Factors affecting the inactivation of micro-organisms by intense light pulses V.M. Go´mez-Lo´pez1,2, F. Devlieghere1, V. Bonduelle1 and J. Debevere1 1

Laboratory of Food Microbiology and Food Preservation, Ghent University, Gent, Belgium, and 2Instituto de Ciencias y Tecnologı´a de Alimentos, Facultad de Ciencias, Universidad Central de Venezuela, Caracas, Venezuela

2004/0979: received 24 August 2004, revised 7 December 2004 and accepted 9 March 2005

ABSTRACT ´ MEZ-LO ´ P E Z , F . D E V L I E G H E R E , V . B O N D U E L L E A N D J . D E B E V E R E . 2005. V.M. GO

Aim: To determine the influence of several factors on the inactivation of micro-organisms by intense light pulses (ILP). Methods and Results: Micro-organisms on agar media were flashed 50 times under different conditions and their inactivation measured. Micro-organisms differed in sensitivity to ILP but no pattern was observed among different groups. Several enumeration methods to quantify the effect of ILP were investigated and showed relevant differences, shading effect and photoreactivation accounted for them, the strike method yielded the most reliable results. Higher decontamination efficiencies were obtained for Petri dishes located close to the strobe and inside the illumination cone. Decontamination efficacy decreased significantly at contamination levels >6Æ85 log10. After 13 successive treatments, no resistance to ILP could be demonstrated. Media warming up depended on the distance from the strobe and the number of flashes. Conclusions: For an industrial implementation: the position and orientation of strobes in an unit will determine the lethality, products should be flashed as soon as possible after contamination occurs, a cooling system should be used for heat-sensitive products and flashed products should be light protected. No resistant flora is expected to develop. Significance and Impact of the Study: Conclusions derived from this work will allow a better implementation of this decontamination technique at industrial level. Keywords: decontamination, food, inactivation, intense light pulses, minimally processed, pulsed UV light, pulsed white light, ultraviolet.

INTRODUCTION Intense light pulses (ILP) is a novel technique proposed to decontaminate surfaces by killing micro-organisms using short time high frequency pulses of an intense broad spectrum, rich in UV-C light. It has potential application for the treatment of food, packages, medical devices, packaging and processing equipments for the food, medical and pharmaceutical industries, and water and air (Dunn et al. 1997). The following names have been used by different Correspondence to: Frank Devlieghere, Laboratory of Food Microbiology and Food Preservation, Ghent University, Coupure Links, 653, 9000 Ghent, Belgium (e-mail: frank.devlieghere@ugent.be).

authors to denominate techniques that can be included in the definition of ILP: pulsed UV light (Sharma and Demirci 2003), high-intensity broad spectrum pulsed light (Roberts and Hope 2003), pulsed UV disintegration (Wekhof 2000) (this term does not comprehend all kinds of ILP treatments), pulsed light (Rowan et al. 1999) and pulsed white light (Marquenie et al. 2003). This technology is grouped by food scientists in the frame of the so called nonthermal technologies, which are intented to produce stable and safe food products without those damages provoked by heating. Different mechanisms have been proposed to explain the lethal effect of ILP, all of them related with the UV part of the spectrum and with its photochemical and/or photothermal ª 2005 The Society for Applied Microbiology


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.