School Design (Regenerative) Fall 2015

Page 1

Exploded Axon-metric Perspective:

MONTESSORI SCHOOL: - Gross area is 10,262 ft^2 - Net area is 9,600 ft^2 - Meets 2030 Living Building Challenge - Net positive building Class rooms Sience/Stem/Green House Art/Environmental-Small Kitchen Language Arts/Reading/Writing Foreign Language

1200 1200 1200

Gymnasium/Fitness/lockers/Showers Cafeteria/Indoor/Outdoor Dining Office/Security Library Mechanical/ Electrical

1200 2400 600 1200 600

Skylights tilted to the north to minimize the harmful direct sunlight that facing the sun bath, and work as solar cells at the same time.

- Students from different ages are grouped together. - As a result; the emphasis is on the student and not on the teacher. - This approach makes each student act and learn by him/her self using his/her own time and schedule. - There is no limit for student to learn as much as they desire. - A focus on how the student react to the environment and people.

Thermal air bucket with exchange solid and glazed panels to give the building more energy control on the north side.

Energy Model:

Cylindrical shaded outdoor spaces to get ambient light from the east and west. Also, they decelerate and calm the north wind in order to avoid using the double door system and save more space

Glazing facing the north side to get sufficient daylight

Low`e glazing panels works as solar panels

Triangular shading devices that get wider as long as they go up. As the same time they match the triangular facade panels

Tilted roofs in all direction that help controlling and directing the rain water to the the tank under the building

Site Plan:

Ground Floor Plan:

Wall Insulation: R8

Wall Insulation: R24

Floor Insulation: R13

Floor Insulation: R21

Roof Insulation: R25

Roof Insulation: R40

Glazing U-Factor: .35

Glazing U-Factor: .25

Visible Light Transmittance: .4

Visible Light Transmittance: .5

Solar Heat Gain Coefficient: .25

Solar Heat Gain Coefficient: .33

Heating Efficiency: .8

Heating Efficiency: 3

Cooling Efficiency: 3

Cooling Efficiency: 3

Infiltration-rate: .39 cfm/ft2

Infiltration-rate: .2 cfm/ft2

Ventilation Rate: .06 cfm/ft2

Ventilation Rate: .04 cfm/ft2

Equipment: .75 W/ft2

Equipment: .2 W/ft2

Lighting: .82 W/ft2

Lighting: .4 W/ft2

Daylight Response Efficiency: 0%

Daylight Response Efficiency: 30%

Section A-A

A

B

B

C

C

Section C-C A

South Elevation

Section B-B

North Elevation: