Uninterruptible Power Supply
Prostar High Frequency UPS Venus Series (1kVA -10kVA) 1:1 Mercury Series (1kVA -10kVA) 1:1
Monitoring Software
USB Port
RS232 Port
ECO Mode
EPO Mode
Generator Support
SNMP Module
High Power Factor
High Frequency Online UPS
Venus Series
Output & Battery Voltage Info
Load Info
Remaining Backup Time Info Mode Operation Info Fault Info Mute Operation Output & Battery Voltage Info
Battery Info
Function Features
1
True double-conversion online UPS A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive
5
networks, small computer centers, servers, telecom applications,
ECO mode operation for energy saving Offers efficiency as high as 97% to cut energy usage &cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
as well as for industrial applications.
2
Output power factor 0.8
Compared to the online UPS in the current market, Venus series UPS provides better output power factor up to 0.8. It offers higher
6
Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case of fires or other emergencies.
performance and effciency for critical applications.
3
Wide input voltage range (110V-300V)
Venus series can still provide stable power to connected devices
7
under unstable power environments.
4
50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
This feature allows either USB,RS232 or Rj45 communication port to work with SNMP interface simultaneously.
8
DSP technology applied for 6-10K models
A DSP controller provides an improved and cost-effective solution with high performance.
www.Prostar-cn.com
Rear Panel View USB and Rs232 communication Ports Internal Slot
CE
Network/Fax/Modem Surge Protection
RoHS
External Batery Connection
Intelligent cooling fan
ISO9001 ISO14001
Output terminal
IQNet Circuit Breaker AC Input
Packing LCD Display
Monitoring Software
USB Port
SNMP Module AS-400 Card Green Power (Option) Dry Contact (ECO Mode) (Option)
RS232 Port
Network/Fax/ Modem Port
2 x Outlets
Generator Support
High Power Factor
Tower Base
6KVA-10KVA
1KVA-3KVA
Monitoring software
Accessory
SNMP Card
AS-400 Card
UPS can be connected to the computer via USB or Rs232 interface. So it can be realized LAN monitoring single or many sets of UPS, it also can monitor the other ups which connected to the computer via LAN. UPS monitoring software has more than 10 kinds of language for choice. Humanized operation interface, which is powerful and can shows the battery voltage, frequency, load, temperature and other data by real-time monitoring through the charts. Alarm of different power incident could be set by radio, mobile phone text messages, e-mails and SNMP etc. Historical data log could be recorded and stored in the computer database, and it could make the events statistics and analysis in the form of chart.
Monitoring software
High Frequency Online UPS
Venus Series
PHT1101
PHT 1KVA~3KVA 1:1
PHT1102
PHT1103
PHT1101B
PHT1102B
PHT1103B
Technical Specification
1KVA~3KVA 1:1
High Frequency Tower UPS PHT1101
PHT1102
PHT1103
PHT1101B
PHT1102B
PHT1103B
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
MODEL CAPACITY Battery Voltage Size, D X W X H (mm)
36V
72V
36V
72V
282 X 145 X 220
397 X 145 X 220
397 X 145 X 220)
419 X 190 X 318
6.8
4.1
Net Weight(kgs)
7.4
13
26
28
Input Low Line Transfer
160VAC/140VAC/120VAC/110VAC±5% 175VAC/155VAC/135VAC/125VAC ±5%
Low Line Comeback
Voltage Range
168 VAC / 148VAC / 128 VAC / 118 VAC ± 5 %
High Line Transfer
300 VAC ± 5 %
High Line Comeback
290 VAC ± 5 %
Frequency Range
40Hz ~ 70 Hz
Phase
Single phase with ground ≥0.99 @ nominal voltage (input voltage)
Power Factor
Output Output voltage
200/208/220/230/240VAC
± 1% (Batt. Mode)
AC Voltage Regulation Frequency Range (Synchronized Range)
47Hz ~ 53 Hz @ 50Hz or 57Hz ~ 63 Hz @ 60Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Frequency Range (Batt. Mode)
105%~110%: UPS shuts down after 10 min at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1min at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal
Overload
100%~110%:audible warning 110%~130%: UPS shuts down in 60 seconds at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal
3:1
Current Crest Ratio ≤3 % THD (Linear Load);≤ 5% THD (Non-linear Load)
Harmonic Distortion
≤3 % THD (linear load);≤ 6 % THD (non-linear load) 0 ms
AC Mode to Batt. Mode Transfer Time
4 ms
Inverter to Bypass
Waveform (Batt. Mode)
Pure Sine Wave
Efficiency AC Mode
88%
89%
90%
87%
Battery Mode
83%
87%
88%
83%
87%
90% 89%
Battery Battery Type
Depending on applications
12V7AH
12V7AH
12V9AH
Battery Numbers
Depending on applications
3
6
6
Recharge Time
Depending on applications
Charging Current Charging Voltage
4 hours recover to 90% capacity 1.0 A (max.)
1.0A/2.0A/4.0A/6.0 A 41.0VDC±1%
82.1 VDC ±1%
82.1 VDC ±1%
41.0VDC ±1%
82.1VDC±1%
Environment Operation Humidity
0-90 % RH @ 0- 40°C (non-condensing)
Noise Level
Less than 50dBA @ 1 Meter
Management Smart RS-232 or USB
Windows 2000/2003/XP/Vista/2008、Windows 7/8、Linux、Unix、MAC
Optional SNMP
Remarks:Products specifications are subject to change without notice.
Power management from SNMP manager and web browser
82.1VDC±1%
www.Prostar-cn.com
PHT1106
PHT1106B PHT1110B
PHT1110
PHT1106
PHT1106
Technical Specification
6KVA~10KVA 1:1
UPS High Frequency Tower UPS PHT1106
PHT1110
PHT1106B
PHT1110B
6000 VA / 4800 W
10000 VA / 8000 W
6000 VA / 4800 W
10000 VA / 8000 W
369 x 190 x 318
442x 190 x 318
369 x 190 x 688
442x 190 x 688
21
23
72
82
MODEL CAPACITY Battery Voltage
192V
Size, D X W X H (mm) Net Weight(kgs)
Input Low Line Transfer Voltage Range
110VAC±3% at 50%Load; 176VAC±3% at 100% Load Low Line Loss Voltage+10V
Low Line Comeback High Line Transfer
300 VAC±3 % High Line Loss Voltage-10V
High Line Comeback
46Hz~54 Hz@50Hz or 56Hz~64 Hz@60Hz
Frequency Range
Single phase with ground
Phase
≥0.99 at 100% Load
Power Factor
Output Output voltage
208/220/230/240VAC ± 1%
AC Voltage Regulation Frequency Range (Synchronized Range)
46Hz~54 Hz @50Hz or 56Hz~64 Hz @60Hz 50Hz±0.1Hz or 60Hz±0.1Hz
Frequency Range (Batt. Mode) AC Mode
100%~110%: 10min、110%~130%: 1min、>130% :1sec
Battery Mode
100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec
Overload
Current Crest Ratio
3:1 max
Harmonic Distortion
≤3%@100% Linear Load;≤6% @ 100% Non-linear Load
Transfer Time
0 ms
AC Mode to Batt. Mode Inverter to Bypass
0 ms Pure Sine Wave
Waveform (Batt. Mode)
Efficiency AC Mode
>89%
>90%
>89%
>90%
Battery Mode
>88%
>89%
>88%
>89%
Battery Battery Type
Depending on applications
Battery Numbers
Depending on applications
16
Recharge Time
Depending on applications
9hours recover to 90% capacity
Default : 4A±10%; Max.: 6A±10%
Default : 1A±10%; Max.: 2A±10%
Charging Current
12V9AH
12V7AH
Charging Voltage
218.4VDC±1%
Environment Operation Temperature
0 ~ 40°C (battery life cycle will be shorten when temperature is above 25°C)
Operation Humidity
<95 % and non-condensing <1000m
Operation Altitude Acoustic Noise Level
<55dB@1Meter
<58dB@1Meter
<55dB@1Meter
Management Smart RS-232 or USB Optional SNMP
Windows 2000/2003/XP/Vista/2008、Windows 7/8、Linux、Unix、MAC Power management from SNMP manager and web browser
Remarks:Products specifications are subject to change without notice.
<58dB@1Meter
High Frequency Rack UPS
Mercury Series
www.Prostar-cn.com
PHT1101/PHT1101B/PHT1102/PHT1103
CE
RoHS
ISO9001 ISO14001
IQNet
PHT1106/PHT1110
Function Features
1
True double-conversion online UPS A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as
5
sensitive networks, small computer centers, servers, telecom
Output power factor 0.8 Compared to the online UPS in the current market, Mercury series UPS provides better output power factorup to 0.8. It offers higher performance and effciency for critical applications.
applications, as well as for industrial applications.
2
Pure sine wave output
With pure sine wave output, guarantees compatibility for all kinds of loads. Its perfect power protection for versatile applications
6
such as networking, telecom and other mission-critical applications.
3
Wide input voltage range (110V-300V)
Mercury series can still provide stable power to connected devices
4
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
Offers efficiency as high as 97% to cut energy usage &cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
7
under unstable power environments.
50/60 Hz Frequency Converter Mode
ECO mode operation for energy saving
Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case of fires or other emergencies.
8
USB+RS232+RJ45+SNMP multiple communication for 1-3K models
This feature allows either USB,RS232 or Rj45 communication port to work with SNMP interface simultaneously.
High Frequency Rack UPS
Mercury Series www.Prostar-cn.com
Monitoring Software
LCD Display
PHR1101 PHR1101B PHR1102
PHR1103
PHR1106
PHR1110
USB Port
Network/Fax/ Modem Port
2 x Outlets SNMP Module AS-400 Card (Option) Dry Contact (Option)
Green Power (ECO Mode)
Generator Support
High Power Factor
Network/Fax/ModemSurge Protection
AC Input
Circuit Breaker
Internal Slot
Intelligent cooling fan
USB and Rs232 communication Ports
Rear Panel View
Output terminal
External Batery Connection
Unique Design Humanized panel display and turnable LCD screen
Front panel with LCD screen, Intuitive display by way of figures and graphics etc, LCD screen can rotate freely, and LCD display can be consistent for both installation of Tower type or Rack
Rack/Tower Type Design
The installation mode of Racks and tower ups can be arbitrary switching, The hangers for racks and the stents for tower ups are random standard required, easy for choosing by users.
mounted type UPS.
Rack Type
Multifunctional Bracket
RS232 Port
Tower Type
Tower Base
Technical Specification
1KVA~10KVA 1:1
High Frequency Rack UPS Model
PHR1101B
Capacity
PHR1101
PHR1102
PHR1103
PHR1106
PHR1110
1000 VA / 800 W
2000 VA / 1600 W
3000 VA / 2400 W
6000 VA / 4800 W
10000 VA / 8000 W
36V
72V
Battery Voltage
380 x 438 x 88
Size, D X W X H (mm)
6.5
13
Net Weight(kgs)
72V
192V
192V
480x 438 x 88
580 x 438 x 88
668 x 438 x 88
10
15
18
8.3
Input Low Line Transfer Voltage Range
110 VAC±3% at 50% Load; 176VAC±3% at100% Load
160VAC/140VAC/120VAC/110VAC±5% 168VAC/148VAC/128VAC/118VAC ± 5 % )
Low Line Comeback
+10V Low Line Loss Voltage +10V
High Line Transfer
300 VAC ± 5 %
300VAC±3 %
High Line Comeback
290 VAC ± 5 %
10V High Line Loss Voltage - 10V
Frequency Range
46Hz~54 Hz @ 50Hz or 56Hz~64 Hz@60Hz
40Hz ~ 70 Hz
Phase
Single phase with ground
Power Factor
≥0.99@nominal voltage (input voltage)
≥0.99 at 100% Load
200/208/220/230/240VAC
208/220/230/240VAC
Output Output voltage
± 1% (Batt. Mode)
± 1%
47Hz ~ 53 Hz @ 50Hz or 57Hz ~ 63 Hz @ 60Hz
46Hz ~ 54 Hz @ 50Hz or 56Hz ~ 64 Hz @ 60Hz
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
100%~110%:audible warning 110%~130%: UPS shuts down in 60 seconds at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal
AC mode :100%~110%: 10minˇ 110%~130%: 1minˇ>130% : 1sec Battery mode :100%~110%: 30secˇ 110%~130%: 10secˇ>130% : 1sec
AC Voltage Regulation Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Overload
Current Crest Ratio
3:1 max
Harmonic Distortion
≤3 % @ 100% Linear Load; ≤6 % @ 100% Non-linear Load 0 ms
AC Mode to Batt. Mode Transfer Time
Inverter to Bypass
4 ms
0 ms
Waveform (Batt. Mode)
Pure Sine Wave
Efficiency AC Mode
87%
Battery Mode
83%
90% 87%
89%
>89%
>90%
>88%
>89%
Battery Battery Type Battery Numbers Recharge Time Charging current Charging Voltage
12V7AH
Depending on applications
3
Depending on applications
4 hours recover to 90% capacity
Depending on applications
1.0 A (max.)
1.0A/2.0A/4.0A/6.0 A ±10%
41.0VDC ± 1%
82.1 VDC ±1%
218.4 VDC ±1%
Environment Operation Temperature
0 ~ 40°C (battery life cycle will be shorten when temperature is above 25°C)
Operation Humidity
<95 % and non-condensing
Operation Altitude Noise Level
<1000m Less than 50dBA @ 1 Meter
Less than 55dB @ 1 Meter
Management Smart RS-232 or USB Optional SNMP
Windows 2000/2003/XP/Vista/2008、Windows 7/8、Linux、Unix、MAC Power management from SNMP manager and web browser
Remarks:Products specifications are subject to change without notice.
Prostar Science & Technology Development Co.,Ltd.
Http://www.Prostar-cn.com
ISO9001
Website
Less than 58dB @ 1 Meter