Catalog ACDC Surge Protectors - Blue series (http://shop.acdc-dcac.eu/)

Page 1

Catalog ACDC Surge Protectors - Blue Series

MULTI-STAGE

Surge Protection CLASS I+II+III Innovated Multi-Stage Surge Protection Single & Three Phase Modular Installation - Hard Wire

Cascade bi-directional EMI-RFI filtering of phase (L) and ground (GND) wire

IEC61643-1 Class I+II+III; IEC60939-2

Mobile Base Station Broadcast Computers

Sensitive Electronic

Telecommunication

Surge Protection

Medical Equipment

Military

Hard Wire Installation Industrial

Eight (8) Stages Surge Protector Residental

NEW INNOVATION APPROACH TO SURGE PROTECTION

GREEN POWER SUPPLY


. . . We Care for Safety of Your Electronic Devices

This catalogue is the part of the Main Catalogue of ACDC DCAC Company Catalog ACDC Surge Protectors - Multi Stage Surge Protection

We reserve the right to introduce changes in performance, dimensions and material in the course of technical progress.


MULTI-STAGE SURGE PROTECTION

ACDC SURGE PROTECTOR EIGHT (8) STAGES SERIES PROTECTOR 1/1 & 3/3 HARD WIRE INSTALLATION - MODULAR SYSTEM CLASS

LPZ

I+II+III

0 1 2 3

SurGe

Type-PI (780; 7100; 7125; 7200) Blue Series Single Phase / Three Phase CLASS I+II+III Voltage Rating: 120VAC /230VAC /400VAC Current Rating: up to 100A per phase Response Time: < 1ns

IP

20

home

telecom

IT center

industry

SurGe Protection

ACDC Surge Protector Type- PI Series is specifically designed to protect, upgrade and improve functioning of computers, telecommunication, medical, audio, video and all sensitive electronic equipment. igh current capability, up to 100A, makes these protectors ideal equally for low power sensitive electrical devices and for industrial application.

H

EASIER SIMPLER BETTER Implementation of ACDC Surge Protectors is simple and easy. Regarding multi-stage design of Class I+II+III in one unit with ACDC Surge Protectors is expel need of several surge protectors installed separately in each boundary protection zone (LPZ0a/LPZ0b-LPZ3 & C-A acc. IEC 62305-4 & ANSI/IEEE C62.41.1-2) ith simple words, design and planning of surge protection is not any more reserved just for experts in this field. It become simple and applicable to wide branch of professions: electrician, const. builders, IT..

W

Empowered by Innovation

ACDC Surge Protector Type - PI (780; 7100; 7125; 7200) Blue Series is advanced multi-stage surge protector consists of 8 (eight) & 100A protection stages that provides effective and reliable protection against surges and transients. The protection device have high grade cascade bidirectional EMI/RFI filtering of phase (L) wire with option for ground (Gnd) filtering. The protector has also special diagnostic for ground condition. Application: The scope of applications of ACDC Surge Protectors is quite wide and refers to the protection of electrical devices against impulse surge and high-frequency (electromagnetic) disturbance, oscillation, speaks in network power supply and atmospheric discharge. ACDC protectors have high-grade bidirectional filtering. They are tracking AC waveform eliminating so-called pollution in power AC supply. These protectors have special design to protect and improve functioning of sophisticate equipment in Telecommunications, Broadcast, Medical equipment, Computers, Military, Solar Photovoltaic and Residental. Technical Specifications: The basic module of type ACDC Surge Protector Blue Series is 8 (eight) stages Single Phase Protector with modular configuration for single or three phase applications for load currents of up to 100A (22kW) per phase. Investment: Installation of ACDC Surge Protector type - PI is excellent choice for investment in the quality of your power network supply, extended equipment life and reduce their down time and errors. Reliability: If the stages 2,4 and 6 are out of function, the stages 1,3 and 7 are still provide a high grade cascade bi-directional filtering along with ultimate (5-th) protection stage. www.acdc-dcac.eu


Technical Specification Type - PI Blue Series

SurGe

MULTI-STAGE SURGE PROTECTION

EIGHT PROTECTION STAGES: Cascade bi-directional EMI-RFI filtering of phase (L) and ground (GND) wire

Basic Circuit Diagram per Phase - Blue Series: Red Yellow Green

LIN for parallel application

LIN for series application

LOUT

Var.

ACDC Surge Protector Type-PI Blue Series

C

Var.

C

Bi-directional Filter (No back EMF effect)

C

Control GTD

Thermal Cut-Off

N C

Bi-directional Filter (No back EMF effect)

TVS Limiter Control GTD

Thermal Cut-Off

N

GTD

GND IN

without filtering

GND IN for ground filtering

for ground filtering

72

82

Philosophy: The ACDC Surge Protectors have coordinated approach to lightning protection, surge and transient protection as well as grounding, an approach that embraces all aspects of potential damage. No single technology can effective protect electronic devices from the damaging effects of lightning and induced transients, which can severely damage or destroy electronic systems.

GND OUT

45

50

70

18

36

In order to provide the optimum level of protection, ACDC has developed integrate 8 (eight) stages Surge protector that provides effective and reliable protection against surges and transients. Approach: ACDC Surge Protectors provides a systematic approach on two fronts: Surge protection and Bi-directional filtration. While there are companies and products that attempt one of these, ACDC Surge Protectors is the only product that seamlessly merges the two technologies. The unique multi-stage design provides the most advanced power filter protector. Technology: ACDC Surge Protector Type-PI Blue Series is protector of class I+II+III in one according to IEC61643. They also full fill standard requirements for electromagnetic (radio) interference IEC60939-2. Design: The integrated modular design for single or three phase applications alloweasy installation on place where surge protection are needed. Installation: The ACDC Surge Protector - Blue Series could be install in series or parallel configuration depending of total load (>100A<). The place of installation could be Main Circuit Board (MCB) or Sub Distribution Board (SDB). acdc-dcac@acdc-dcac.eu

SIDE VIEW

TOP VIEW

Innovation Approuch to Surge Protection ACDC Multi-Stage Surge Protectors have built-in five (5) patents and use four (4) complementary different protection technologies, (Varistor, Gas Tube, Nanocrystalline Cores and TVS technology) in one unit. That result with reducing the surge current up to 99.9% at single point.

T

his characteristic can not offer competitive surge products and present a fundamental improvement in Surge Protection technology. Implementation of ACDC Surge Protectors aresimple and applicable for professions such as planners, construction engineers, designers, electricians and others.

New materials, New design, New approach to Surge Protection Industry


MULTI-STAGE SURGE PROTECTION

Technical Specification

SurGe

Type - PI Blue Series

Technical Specification per Phase ACDC Surge Protector - Blue Series Type Order Code Total Surge Current Product Standard

Type PI 780 - BS

Type PI 7100 - BS

Type PI 7125 - BS

Type PI 7200 - BS

800.125

800.126

800.127

800.128

Surge Cur. 105kA (8/20μs) or 15kA (10/350μs)

Surge Cur. 125kA (8/20μs) or 18kA (10/350μs)

Surge Cur. 150kA (8/20μs) or 22kA (10/350μs)

Surge Cur. 225kA (8/20μs) or 32kA (10/350μs)

IEC61643-1 Class I+II+III (B+C+D); IEC60939-2

1. Stage

First Protection Stage

Function

Bi-directional filtering EMI/RFI (L-N); Front signal edge reduction;

Technical Specification

L=4.2mH; Imax=up to 100A

Technology

Nano Crystalline Core (L-C configuration)

2. Stage

Second Protection Stage

Function

Suppression signal shape (L-N), 8/20μs or 10/350μs

Technical Specification Technology

Surge Cur. 80kA (8/20μs) or 12,5kA (10/350μs)

Surge Cur. 100kA (8/20μs) or 15kA (10/350μs)

Surge Cur. 125kA (8/20μs) or 20kA (10/350μs)

Surge Cur. 200kA (8/20μs) or 30kA (10/350μs)

Varistor with thermal cut-off; Control Gas Tube Discharge

3. Stage

Third Protection Stage

Function

Bi-directional filtering EMI/RFI (L-N); Front signal edge reduction

Technical Specification

L=0.7mH; Imax=up to 100A

Technology

Nano Crystalline Core (L-C configuration)

4. Stage

Fourth Protection Stage

Function

Suppression signal shape (L-N), 8/20μs Surge Cur. 25kA (8/20μs)

Technical Specification Technology

Varistor with thermal cut-off

5. Stage

Fifth Protection Stage

Function Technical Specification

Long term signal suppression from 1μs to 2 sec. This stage is the last ultimate protection level. He switch-off the circuits breaker install upstream, if the pick voltage > 300DC for (120 VAC) or 520VDC for (230 VDC) appears on the output. Circuits breaker should be < 250A gl/gG.

Technology

Controlled Gas Tube Discharge

6. Stage

Sixth Protection Stage

Function

High speed efficiency signal suppression

Technical Specification

TVS Limiter 500A (8/20μs); Typical response < 1nsec (nanosecond)

Technology

Transient Voltage Suppressor

7. Stage

Seventh Protection Stage

Function

Ground filtering

Technical Specification

L=0,7mH

Technology

Nano Crystalline Core (L-C configuration)

8. Stage Function Technical Specification Technology

Eight Protection Stage Suppression signal shape (N-Gnd), 8/20μs or 10/350μs Surge Cur. 80kA (8/20μs) or 12,5kA (10/350μs)

Surge Cur. 100kA (8/20μs) or 15kA (10/350μs)

Surge Cur. 125kA (8/20μs) or 20kA (10/350μs)

Surge Cur. 200kA (8/20μs) or 30kA (10/350μs)

Controlled Gas Tube Discharge

www.acdc-dcac.eu Integrated Multi-Stage Protection

www.acdc-dcac.eu


Models of Surge Protectors

MULTI-STAGE SURGE PROTECTION

SurGe

Type - PI Blue Series

Single and Three phase Models - ACDC Surge Protectors - Blue Series Guideline for ordering of ACDC Surge Protectors of Blue Series Technology:

Multi-Stage Surge Protection; Eight (8) Stages Series Protector

Specification:

Cascade bi-directional EMI-RFI filtering of phase (L) wire and ground (GND) wire

Load:

Up to 100A per phase; 12kW per phase for 120VAC; 22kW per phase for 230VAC

Options:

Ground filtering, indication for bed grounding, remote alarm

Installation:

Hard wire installation - Modular System

Product Standard:

IEC61643-1 Class I+II+III; IEC60939-2

Single Phase

For upgrade the distribution panel Order Code

Type

Three Phase

Type-PI 780 1/1-BS

800.125-1/1

Type-PI 7100 1/1-BS

800.126-1/1

Type - PI 7125 1/1-BS

800.127-1/1

Type - PI 7200 1/1-BS

800.128-1/1

Order Code

Type-PI 780 1/1-BS x 3

800.125-1/1 x 3

Type-PI 7100 1/1-BS x 3

800.126-1/1 x 3

Type - PI 7125 1/1-BS x 3

800.127-1/1 x 3

Type - PI 7200 1/1-BS x 3

800.128-1/1 x 3

Weight

(WxDxHmm)

(kg)

82x72x70

0,47

82x72x70

0,47

82x72x70

0,47

82x72x70

0,47

Total Surge Cur. 315kA(8/20μs) or 45kA(10/350μs) 375kA (8/20μs) or 54kA (10/350μs) 450kA (8/20μs) or 66kA (10/350μs) 675kA (8/20μs) or 96kA (10/350μs)

Dimension

Weight

(WxDxHmm)

(kg)

82x216x70

1,41

82x216x70

1,41

82x216x70

1,41

82x216x70

1,41

The Surge Protectors are installed in Metal Distribution board with degree of protection IP54 Order Code

Type

Three Phase

105kA(8/20μs) or 15kA(10/350μs) 125kA (8/20μs) or 18kA (10/350μs) 150kA (8/20μs) or 22kA (10/350μs) 225kA (8/20μs) or 32kA (10/350μs)

Dimension

For upgrade the distribution panel Three single phase surge protectors connected for three phase application Type

Three Phase

Total Surge Cur.

Type-PI 780 3/3-M-BS

800.125-3/3-M

Type-PI 7100 3/3-M-BS

800.126-3/3-M

Type - PI 7125 3/3-M-BS

800.127-3/3-M

Type - PI 7200 3/3-M-BS

800.128-3/3-M

Total Surge Cur. 315kA(8/20μs) or 45kA(10/350μs) 375kA (8/20μs) or 54kA (10/350μs) 450kA (8/20μs) or 66kA (10/350μs) 675kA (8/20μs) or 96kA (10/350μs)

Dimension

Weight

(WxDxHmm)

(kg)

250x250x150

5,1

250x250x150

5,1

250x250x150

5,1

250x250x150

5,1

The Surge Protectors are installed in Metal Distribution board with degree of protection IP54 Circuit breakers MCB 100A are installed in the front of protectors for each phase Order Code

Type Type-PI 780 3/3-MCB-BS

800.125-3/3-MCB

Type-PI 7100 3/3-MCB-BS

800.126-3/3-MCB

Type - PI 7125 3/3-MCB-BS

800.127-3/3-MCB

Type - PI 7200 3/3-MCB-BS

800.128-3/3-MCB

Total Surge Cur. 315kA(8/20μs) or 45kA(10/350μs) 375kA (8/20μs) or 54kA (10/350μs) 450kA (8/20μs) or 66kA (10/350μs) 675kA (8/20μs) or 96kA (10/350μs)

Dimension

Weight

(WxDxHmm)

(kg)

300x250x150

7,1

300x250x150

7,1

300x250x150

7,1

300x250x150

7,1

* The Surge Protectors from series Type-PI 3/3-MBC-BS are delivered without ground filtering as model basic option. By customer request the model could be delivered for installation with ground filtering or for parallel installation with additional mark GF or P

www.acdc-dcac.eu acdc-dcac@acdc-dcac.eu

ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia

Phone: 389 2 3216 988; Fax: 389 2 3216 993


MULTI-STAGE SURGE PROTECTION

Operation Diagnostic

SurGe

Application

Operation Diagnostic System Normal:

Red

Yellow

Green Led Indication for correct stage no. 2,4 and 6. The stages no. 1,3 and 7 (high garde bi-directional filtering) are always in function along with ultimate (5-th) protection stage.

Continuous yellow and green

Fault: Led Indication for correct stage no. 4,6 and un correct no 2. The stages no. 1,3 and 7 (bi-directional filtering) are always in function along with ultimate (5-th) protection stage.

Continuous green

Fault: Led Indication for bed grounding (Low impedance equipotential ground is not provided)

Blinking red

Fault: Continuous red

Only stages 1,3 and 7 are still in function along with ultimate (5-th) protection stage.

Frequency attenuation: - 10dB

- 40dB

- 80dB

0

-20

-40

-60

-80

10

100

1k

10k

100k

0.1

1k

10k

Application:

100k

Home

Voltage Spike

Safe Power Supply

U(V)

800k

1M

Mobile Base Station

Telekom

Uef

5

10

15

20

t (ms)

Industry Random Noice

Certificate of Quality ISO 9001:2008 Varistors Standard IEC 61643-1; UL 1449 Elect. Magn. Interfer. IEC 60939-2 Protec. Standard acc. IEC 61643-1 Class I+II +III

Integrated Multi-Stage Protection

Solar

Wind energy

Waveform Tracking Filter

Applications:

Features:

Telecommunication Medical equipment Military Computers Sensitive electronic Solars Industrial grade

Multi - Stage Surge Protection Eight (8) Protection Stages Bi-directional Filtering Ground Filtering Thermal Circuit Protection High Reliability Excellent Response Time < 1ns

www.acdc-dcac.eu


Installation Instruction

MULTI-STAGE SURGE PROTECTION

SurGe

Type - PI Blue Series

Installation Instruction for TN-C-S, TN-S and TT distribution system SERIES - Single Phase Installation with phase (L) and ground (GND) filtering Fuse

L

SERIES - Three Phase Installation with phase (L) and ground (GND) filtering L1

Fuse

L2

Fuse

L3

Fuse

N

N

PE

PE

LIN

L

PARALLEL

L LOUT

LIN

PARALLEL

L

PARALLEL

L LOUT LIN

PARALLEL

MULTI-STAGE

Type - PI Blue Series Load Rating: 230VAC @ 100A

GND II IV,VI

SURGE

GND II IV,VI

Type - PI Blue Series Load Rating: 230VAC @ 100A

GND II IV,VI

Fuse

L2

Fuse

L3

Fuse

PE

L LOUT

LIN

PARALLEL

L

PARALLEL

L LOUT LIN

PARALLEL

L

PARALLEL

L LOUT LIN

PARALLEL

MULTI-STAGE

MULTI-STAGE

MULTI-STAGE

PROTECTION

PROTECTION

PROTECTION

SURGE

N

GIN GOUT

SURGE

Series

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

GND II IV,VI

L

PARALLEL

L LOUT

PARALLEL

MULTI-STAGE

SURGE

Series

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

GND II IV,VI

SURGE

PROTECTION

Series

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

GND II IV,VI

Series

Blue

GND II IV,VI

CORRECT

CORRECT

FAULT

CLASS I+II+III

CORRECT

CORRECT

FAULT

CLASS I+II+III

CORRECT

mark

mark

mark

mark

GIN GOUT

GIN GOUT N

N

GIN GOUT N

GIN GOUT

L

L LOUT LIN

PARALLEL - Single Phase Installation ( for current > 100A per phase ) Fuse

C1'

N

CORRECT

CORRECT

N

FAULT

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

CLASS I+II+III

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

CORRECT

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

FAULT

CLASS I+II+III

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

N

CORRECT

mark

GIN GOUT N

N

CORRECT

mark

GIN GOUT N

FAULT

CLASS I+II+III

CORRECT

CORRECT

FAULT

L1

PE

ACDC SURGE PROTECTOR Type - PI 7125 Blue Series Load Rating: 230VAC @ 100A

CLASS I+II+III

N

SERIES - Three Phase Installation with phase (L) and without ground (GND) filtering

N

L

CORRECT

N

N

PARALLEL

CORRECT

CORRECT

mark

Fuse

LIN

FAULT

1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

CLASS I+II+III

1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

CORRECT

1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

FAULT

CLASS I+II+III

1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

GIN GOUT

Blue

GND II IV,VI

EIGHT PROTECTION STAGES

N

Series

ACDC SURGE PROTECTOR

Blue

EIGHT PROTECTION STAGES

SERIES - Single Phase Installation with phase (L) and without ground (GND) filtering

C1

Type - PI Blue Series Load Rating: 230VAC @ 100A

PROTECTION

Series

ACDC SURGE PROTECTOR

Blue

EIGHT PROTECTION STAGES

mark

L

MULTI-STAGE

PROTECTION

Series

ACDC SURGE PROTECTOR

L LOUT

PARALLEL

SURGE

PROTECTION

Series

Blue

L

PARALLEL

MULTI-STAGE

EIGHT PROTECTION STAGES

N

L

L LOUT LIN

PARALLEL

SURGE

PROTECTION

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

L

PARALLEL

MULTI-STAGE

SURGE

N

N

N

PARALLEL - Three Phase Installation ( for current > 100A per phase ) L1

C1

Fuse

L2

C2

Fuse

L3

C3

Fuse

N PE

PE

C1'

LIN

L

PARALLEL

L LOUT

LIN

PARALLEL

C2'

L

PARALLEL

L LOUT LIN

PARALLEL

MULTI-STAGE

SURGE

II

PARALLEL

SURGE

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

IV,VI

L

PARALLEL

L LOUT

PARALLEL

MULTI-STAGE

MULTI-STAGE

SURGE

PROTECTION

Series

Blue

GND

PARALLEL

MULTI-STAGE

PROTECTION

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

C3'

SURGE

PROTECTION

Series

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

GND II IV,VI

PROTECTION

Series

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

GND II IV,VI

CORRECT

ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia

CORRECT

mark

N

GND II IV,VI

FAULT

CORRECT

GIN GOUT N

CLASS I+II+III

N

CORRECT

mark

N

FAULT

CORRECT

acdc-dcac@acdc-dcac.eu

CLASS I+II+III

GIN GOUT

CORRECT

N

FAULT

mark

N

CLASS I+II+III

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

CORRECT

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

CORRECT

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

FAULT

CLASS I+II+III

EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)

Series

Blue

mark

GIN GOUT N

N

GIN GOUT

Phone: 389 2 3216 988; Fax: 389 2 3216 993


. . . ACDC DCAC for Your Safety


surge

I (kA) Iimp

100

80

Imax

Wave 8x20μs

40

20

10

Uef

200

100

300

400

500

600

700

800

900

1000

t (μs)

Voltage Spike

U(V) +Uc

Wave 10x350μs

60

Random Noice Destructive Voltage

+ Umax√2 + Umax/√2

5

Safe Power Supply 10

15

20

t (ms)

50Hz Sinusoidal -Uc - Umax√2

Waveform Tracking Filter

Yellow Series

Pink Series

Orange Series

Red Series

ACDC Surge Protector

Blue Series

Protection

Green Series

Surge

Destructive Voltage

Single Phase Application

Three Phase Signal Line

Installation

Hard Wire Plug In

Connection

Series Connection Parallel Connection (Optional) Signal. for Ground Condition

Grounding

Option for ground Filtering No Ground Contamination

Degree of Protection

Eight (8) Stages Surge Protector

*

Three (3) Stages Surge Protector Three Stages Signalization

Signalization

AC Signalization

Products Manufacture by ACDC DCAC Multi-Stage Surge Protection

Signal Line Signalization Modularity Options

Free Contact Alarm Degree of Enclosures IP54, IP65

Standards

IEC61643-1 Class I+II+III; IEC60939-2

IEC61643-21

*

Dane Krapcev no.2/1 1000 Skopje, Macedonia Phone: 389 2 3216 988 Fax: 389 2 3216 993 acdc-dcac@acdc-dcac.eu www.acdc-dcac.eu