Catalog ACDC Surge Protectors - Blue Series
MULTI-STAGE
Surge Protection CLASS I+II+III Innovated Multi-Stage Surge Protection Single & Three Phase Modular Installation - Hard Wire
Cascade bi-directional EMI-RFI filtering of phase (L) and ground (GND) wire
IEC61643-1 Class I+II+III; IEC60939-2
Mobile Base Station Broadcast Computers
Sensitive Electronic
Telecommunication
Surge Protection
Medical Equipment
Military
Hard Wire Installation Industrial
Eight (8) Stages Surge Protector Residental
NEW INNOVATION APPROACH TO SURGE PROTECTION
GREEN POWER SUPPLY
. . . We Care for Safety of Your Electronic Devices
This catalogue is the part of the Main Catalogue of ACDC DCAC Company Catalog ACDC Surge Protectors - Multi Stage Surge Protection
We reserve the right to introduce changes in performance, dimensions and material in the course of technical progress.
MULTI-STAGE SURGE PROTECTION
ACDC SURGE PROTECTOR EIGHT (8) STAGES SERIES PROTECTOR 1/1 & 3/3 HARD WIRE INSTALLATION - MODULAR SYSTEM CLASS
LPZ
I+II+III
0 1 2 3
SurGe
Type-PI (780; 7100; 7125; 7200) Blue Series Single Phase / Three Phase CLASS I+II+III Voltage Rating: 120VAC /230VAC /400VAC Current Rating: up to 100A per phase Response Time: < 1ns
IP
20
home
telecom
IT center
industry
SurGe Protection
ACDC Surge Protector Type- PI Series is specifically designed to protect, upgrade and improve functioning of computers, telecommunication, medical, audio, video and all sensitive electronic equipment. igh current capability, up to 100A, makes these protectors ideal equally for low power sensitive electrical devices and for industrial application.
H
EASIER SIMPLER BETTER Implementation of ACDC Surge Protectors is simple and easy. Regarding multi-stage design of Class I+II+III in one unit with ACDC Surge Protectors is expel need of several surge protectors installed separately in each boundary protection zone (LPZ0a/LPZ0b-LPZ3 & C-A acc. IEC 62305-4 & ANSI/IEEE C62.41.1-2) ith simple words, design and planning of surge protection is not any more reserved just for experts in this field. It become simple and applicable to wide branch of professions: electrician, const. builders, IT..
W
Empowered by Innovation
ACDC Surge Protector Type - PI (780; 7100; 7125; 7200) Blue Series is advanced multi-stage surge protector consists of 8 (eight) & 100A protection stages that provides effective and reliable protection against surges and transients. The protection device have high grade cascade bidirectional EMI/RFI filtering of phase (L) wire with option for ground (Gnd) filtering. The protector has also special diagnostic for ground condition. Application: The scope of applications of ACDC Surge Protectors is quite wide and refers to the protection of electrical devices against impulse surge and high-frequency (electromagnetic) disturbance, oscillation, speaks in network power supply and atmospheric discharge. ACDC protectors have high-grade bidirectional filtering. They are tracking AC waveform eliminating so-called pollution in power AC supply. These protectors have special design to protect and improve functioning of sophisticate equipment in Telecommunications, Broadcast, Medical equipment, Computers, Military, Solar Photovoltaic and Residental. Technical Specifications: The basic module of type ACDC Surge Protector Blue Series is 8 (eight) stages Single Phase Protector with modular configuration for single or three phase applications for load currents of up to 100A (22kW) per phase. Investment: Installation of ACDC Surge Protector type - PI is excellent choice for investment in the quality of your power network supply, extended equipment life and reduce their down time and errors. Reliability: If the stages 2,4 and 6 are out of function, the stages 1,3 and 7 are still provide a high grade cascade bi-directional filtering along with ultimate (5-th) protection stage. www.acdc-dcac.eu
Technical Specification Type - PI Blue Series
SurGe
MULTI-STAGE SURGE PROTECTION
EIGHT PROTECTION STAGES: Cascade bi-directional EMI-RFI filtering of phase (L) and ground (GND) wire
Basic Circuit Diagram per Phase - Blue Series: Red Yellow Green
LIN for parallel application
LIN for series application
LOUT
Var.
ACDC Surge Protector Type-PI Blue Series
C
Var.
C
Bi-directional Filter (No back EMF effect)
C
Control GTD
Thermal Cut-Off
N C
Bi-directional Filter (No back EMF effect)
TVS Limiter Control GTD
Thermal Cut-Off
N
GTD
GND IN
without filtering
GND IN for ground filtering
for ground filtering
72
82
Philosophy: The ACDC Surge Protectors have coordinated approach to lightning protection, surge and transient protection as well as grounding, an approach that embraces all aspects of potential damage. No single technology can effective protect electronic devices from the damaging effects of lightning and induced transients, which can severely damage or destroy electronic systems.
GND OUT
45
50
70
18
36
In order to provide the optimum level of protection, ACDC has developed integrate 8 (eight) stages Surge protector that provides effective and reliable protection against surges and transients. Approach: ACDC Surge Protectors provides a systematic approach on two fronts: Surge protection and Bi-directional filtration. While there are companies and products that attempt one of these, ACDC Surge Protectors is the only product that seamlessly merges the two technologies. The unique multi-stage design provides the most advanced power filter protector. Technology: ACDC Surge Protector Type-PI Blue Series is protector of class I+II+III in one according to IEC61643. They also full fill standard requirements for electromagnetic (radio) interference IEC60939-2. Design: The integrated modular design for single or three phase applications alloweasy installation on place where surge protection are needed. Installation: The ACDC Surge Protector - Blue Series could be install in series or parallel configuration depending of total load (>100A<). The place of installation could be Main Circuit Board (MCB) or Sub Distribution Board (SDB). acdc-dcac@acdc-dcac.eu
SIDE VIEW
TOP VIEW
Innovation Approuch to Surge Protection ACDC Multi-Stage Surge Protectors have built-in five (5) patents and use four (4) complementary different protection technologies, (Varistor, Gas Tube, Nanocrystalline Cores and TVS technology) in one unit. That result with reducing the surge current up to 99.9% at single point.
T
his characteristic can not offer competitive surge products and present a fundamental improvement in Surge Protection technology. Implementation of ACDC Surge Protectors aresimple and applicable for professions such as planners, construction engineers, designers, electricians and others.
New materials, New design, New approach to Surge Protection Industry
MULTI-STAGE SURGE PROTECTION
Technical Specification
SurGe
Type - PI Blue Series
Technical Specification per Phase ACDC Surge Protector - Blue Series Type Order Code Total Surge Current Product Standard
Type PI 780 - BS
Type PI 7100 - BS
Type PI 7125 - BS
Type PI 7200 - BS
800.125
800.126
800.127
800.128
Surge Cur. 105kA (8/20μs) or 15kA (10/350μs)
Surge Cur. 125kA (8/20μs) or 18kA (10/350μs)
Surge Cur. 150kA (8/20μs) or 22kA (10/350μs)
Surge Cur. 225kA (8/20μs) or 32kA (10/350μs)
IEC61643-1 Class I+II+III (B+C+D); IEC60939-2
1. Stage
First Protection Stage
Function
Bi-directional filtering EMI/RFI (L-N); Front signal edge reduction;
Technical Specification
L=4.2mH; Imax=up to 100A
Technology
Nano Crystalline Core (L-C configuration)
2. Stage
Second Protection Stage
Function
Suppression signal shape (L-N), 8/20μs or 10/350μs
Technical Specification Technology
Surge Cur. 80kA (8/20μs) or 12,5kA (10/350μs)
Surge Cur. 100kA (8/20μs) or 15kA (10/350μs)
Surge Cur. 125kA (8/20μs) or 20kA (10/350μs)
Surge Cur. 200kA (8/20μs) or 30kA (10/350μs)
Varistor with thermal cut-off; Control Gas Tube Discharge
3. Stage
Third Protection Stage
Function
Bi-directional filtering EMI/RFI (L-N); Front signal edge reduction
Technical Specification
L=0.7mH; Imax=up to 100A
Technology
Nano Crystalline Core (L-C configuration)
4. Stage
Fourth Protection Stage
Function
Suppression signal shape (L-N), 8/20μs Surge Cur. 25kA (8/20μs)
Technical Specification Technology
Varistor with thermal cut-off
5. Stage
Fifth Protection Stage
Function Technical Specification
Long term signal suppression from 1μs to 2 sec. This stage is the last ultimate protection level. He switch-off the circuits breaker install upstream, if the pick voltage > 300DC for (120 VAC) or 520VDC for (230 VDC) appears on the output. Circuits breaker should be < 250A gl/gG.
Technology
Controlled Gas Tube Discharge
6. Stage
Sixth Protection Stage
Function
High speed efficiency signal suppression
Technical Specification
TVS Limiter 500A (8/20μs); Typical response < 1nsec (nanosecond)
Technology
Transient Voltage Suppressor
7. Stage
Seventh Protection Stage
Function
Ground filtering
Technical Specification
L=0,7mH
Technology
Nano Crystalline Core (L-C configuration)
8. Stage Function Technical Specification Technology
Eight Protection Stage Suppression signal shape (N-Gnd), 8/20μs or 10/350μs Surge Cur. 80kA (8/20μs) or 12,5kA (10/350μs)
Surge Cur. 100kA (8/20μs) or 15kA (10/350μs)
Surge Cur. 125kA (8/20μs) or 20kA (10/350μs)
Surge Cur. 200kA (8/20μs) or 30kA (10/350μs)
Controlled Gas Tube Discharge
www.acdc-dcac.eu Integrated Multi-Stage Protection
www.acdc-dcac.eu
Models of Surge Protectors
MULTI-STAGE SURGE PROTECTION
SurGe
Type - PI Blue Series
Single and Three phase Models - ACDC Surge Protectors - Blue Series Guideline for ordering of ACDC Surge Protectors of Blue Series Technology:
Multi-Stage Surge Protection; Eight (8) Stages Series Protector
Specification:
Cascade bi-directional EMI-RFI filtering of phase (L) wire and ground (GND) wire
Load:
Up to 100A per phase; 12kW per phase for 120VAC; 22kW per phase for 230VAC
Options:
Ground filtering, indication for bed grounding, remote alarm
Installation:
Hard wire installation - Modular System
Product Standard:
IEC61643-1 Class I+II+III; IEC60939-2
Single Phase
For upgrade the distribution panel Order Code
Type
Three Phase
Type-PI 780 1/1-BS
800.125-1/1
Type-PI 7100 1/1-BS
800.126-1/1
Type - PI 7125 1/1-BS
800.127-1/1
Type - PI 7200 1/1-BS
800.128-1/1
Order Code
Type-PI 780 1/1-BS x 3
800.125-1/1 x 3
Type-PI 7100 1/1-BS x 3
800.126-1/1 x 3
Type - PI 7125 1/1-BS x 3
800.127-1/1 x 3
Type - PI 7200 1/1-BS x 3
800.128-1/1 x 3
Weight
(WxDxHmm)
(kg)
82x72x70
0,47
82x72x70
0,47
82x72x70
0,47
82x72x70
0,47
Total Surge Cur. 315kA(8/20μs) or 45kA(10/350μs) 375kA (8/20μs) or 54kA (10/350μs) 450kA (8/20μs) or 66kA (10/350μs) 675kA (8/20μs) or 96kA (10/350μs)
Dimension
Weight
(WxDxHmm)
(kg)
82x216x70
1,41
82x216x70
1,41
82x216x70
1,41
82x216x70
1,41
The Surge Protectors are installed in Metal Distribution board with degree of protection IP54 Order Code
Type
Three Phase
105kA(8/20μs) or 15kA(10/350μs) 125kA (8/20μs) or 18kA (10/350μs) 150kA (8/20μs) or 22kA (10/350μs) 225kA (8/20μs) or 32kA (10/350μs)
Dimension
For upgrade the distribution panel Three single phase surge protectors connected for three phase application Type
Three Phase
Total Surge Cur.
Type-PI 780 3/3-M-BS
800.125-3/3-M
Type-PI 7100 3/3-M-BS
800.126-3/3-M
Type - PI 7125 3/3-M-BS
800.127-3/3-M
Type - PI 7200 3/3-M-BS
800.128-3/3-M
Total Surge Cur. 315kA(8/20μs) or 45kA(10/350μs) 375kA (8/20μs) or 54kA (10/350μs) 450kA (8/20μs) or 66kA (10/350μs) 675kA (8/20μs) or 96kA (10/350μs)
Dimension
Weight
(WxDxHmm)
(kg)
250x250x150
5,1
250x250x150
5,1
250x250x150
5,1
250x250x150
5,1
The Surge Protectors are installed in Metal Distribution board with degree of protection IP54 Circuit breakers MCB 100A are installed in the front of protectors for each phase Order Code
Type Type-PI 780 3/3-MCB-BS
800.125-3/3-MCB
Type-PI 7100 3/3-MCB-BS
800.126-3/3-MCB
Type - PI 7125 3/3-MCB-BS
800.127-3/3-MCB
Type - PI 7200 3/3-MCB-BS
800.128-3/3-MCB
Total Surge Cur. 315kA(8/20μs) or 45kA(10/350μs) 375kA (8/20μs) or 54kA (10/350μs) 450kA (8/20μs) or 66kA (10/350μs) 675kA (8/20μs) or 96kA (10/350μs)
Dimension
Weight
(WxDxHmm)
(kg)
300x250x150
7,1
300x250x150
7,1
300x250x150
7,1
300x250x150
7,1
* The Surge Protectors from series Type-PI 3/3-MBC-BS are delivered without ground filtering as model basic option. By customer request the model could be delivered for installation with ground filtering or for parallel installation with additional mark GF or P
www.acdc-dcac.eu acdc-dcac@acdc-dcac.eu
ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia
Phone: 389 2 3216 988; Fax: 389 2 3216 993
MULTI-STAGE SURGE PROTECTION
Operation Diagnostic
SurGe
Application
Operation Diagnostic System Normal:
Red
Yellow
Green Led Indication for correct stage no. 2,4 and 6. The stages no. 1,3 and 7 (high garde bi-directional filtering) are always in function along with ultimate (5-th) protection stage.
Continuous yellow and green
Fault: Led Indication for correct stage no. 4,6 and un correct no 2. The stages no. 1,3 and 7 (bi-directional filtering) are always in function along with ultimate (5-th) protection stage.
Continuous green
Fault: Led Indication for bed grounding (Low impedance equipotential ground is not provided)
Blinking red
Fault: Continuous red
Only stages 1,3 and 7 are still in function along with ultimate (5-th) protection stage.
Frequency attenuation: - 10dB
- 40dB
- 80dB
0
-20
-40
-60
-80
10
100
1k
10k
100k
0.1
1k
10k
Application:
100k
Home
Voltage Spike
Safe Power Supply
U(V)
800k
1M
Mobile Base Station
Telekom
Uef
5
10
15
20
t (ms)
Industry Random Noice
Certificate of Quality ISO 9001:2008 Varistors Standard IEC 61643-1; UL 1449 Elect. Magn. Interfer. IEC 60939-2 Protec. Standard acc. IEC 61643-1 Class I+II +III
Integrated Multi-Stage Protection
Solar
Wind energy
Waveform Tracking Filter
Applications:
Features:
Telecommunication Medical equipment Military Computers Sensitive electronic Solars Industrial grade
Multi - Stage Surge Protection Eight (8) Protection Stages Bi-directional Filtering Ground Filtering Thermal Circuit Protection High Reliability Excellent Response Time < 1ns
www.acdc-dcac.eu
Installation Instruction
MULTI-STAGE SURGE PROTECTION
SurGe
Type - PI Blue Series
Installation Instruction for TN-C-S, TN-S and TT distribution system SERIES - Single Phase Installation with phase (L) and ground (GND) filtering Fuse
L
SERIES - Three Phase Installation with phase (L) and ground (GND) filtering L1
Fuse
L2
Fuse
L3
Fuse
N
N
PE
PE
LIN
L
PARALLEL
L LOUT
LIN
PARALLEL
L
PARALLEL
L LOUT LIN
PARALLEL
MULTI-STAGE
Type - PI Blue Series Load Rating: 230VAC @ 100A
GND II IV,VI
SURGE
GND II IV,VI
Type - PI Blue Series Load Rating: 230VAC @ 100A
GND II IV,VI
Fuse
L2
Fuse
L3
Fuse
PE
L LOUT
LIN
PARALLEL
L
PARALLEL
L LOUT LIN
PARALLEL
L
PARALLEL
L LOUT LIN
PARALLEL
MULTI-STAGE
MULTI-STAGE
MULTI-STAGE
PROTECTION
PROTECTION
PROTECTION
SURGE
N
GIN GOUT
SURGE
Series
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
Blue
GND II IV,VI
L
PARALLEL
L LOUT
PARALLEL
MULTI-STAGE
SURGE
Series
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
Blue
GND II IV,VI
SURGE
PROTECTION
Series
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
Blue
GND II IV,VI
Series
Blue
GND II IV,VI
CORRECT
CORRECT
FAULT
CLASS I+II+III
CORRECT
CORRECT
FAULT
CLASS I+II+III
CORRECT
mark
mark
mark
mark
GIN GOUT
GIN GOUT N
N
GIN GOUT N
GIN GOUT
L
L LOUT LIN
PARALLEL - Single Phase Installation ( for current > 100A per phase ) Fuse
C1'
N
CORRECT
CORRECT
N
FAULT
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
CLASS I+II+III
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
CORRECT
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
FAULT
CLASS I+II+III
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
N
CORRECT
mark
GIN GOUT N
N
CORRECT
mark
GIN GOUT N
FAULT
CLASS I+II+III
CORRECT
CORRECT
FAULT
L1
PE
ACDC SURGE PROTECTOR Type - PI 7125 Blue Series Load Rating: 230VAC @ 100A
CLASS I+II+III
N
SERIES - Three Phase Installation with phase (L) and without ground (GND) filtering
N
L
CORRECT
N
N
PARALLEL
CORRECT
CORRECT
mark
Fuse
LIN
FAULT
1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
CLASS I+II+III
1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
CORRECT
1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
FAULT
CLASS I+II+III
1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
GIN GOUT
Blue
GND II IV,VI
EIGHT PROTECTION STAGES
N
Series
ACDC SURGE PROTECTOR
Blue
EIGHT PROTECTION STAGES
SERIES - Single Phase Installation with phase (L) and without ground (GND) filtering
C1
Type - PI Blue Series Load Rating: 230VAC @ 100A
PROTECTION
Series
ACDC SURGE PROTECTOR
Blue
EIGHT PROTECTION STAGES
mark
L
MULTI-STAGE
PROTECTION
Series
ACDC SURGE PROTECTOR
L LOUT
PARALLEL
SURGE
PROTECTION
Series
Blue
L
PARALLEL
MULTI-STAGE
EIGHT PROTECTION STAGES
N
L
L LOUT LIN
PARALLEL
SURGE
PROTECTION
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
L
PARALLEL
MULTI-STAGE
SURGE
N
N
N
PARALLEL - Three Phase Installation ( for current > 100A per phase ) L1
C1
Fuse
L2
C2
Fuse
L3
C3
Fuse
N PE
PE
C1'
LIN
L
PARALLEL
L LOUT
LIN
PARALLEL
C2'
L
PARALLEL
L LOUT LIN
PARALLEL
MULTI-STAGE
SURGE
II
PARALLEL
SURGE
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
IV,VI
L
PARALLEL
L LOUT
PARALLEL
MULTI-STAGE
MULTI-STAGE
SURGE
PROTECTION
Series
Blue
GND
PARALLEL
MULTI-STAGE
PROTECTION
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
C3'
SURGE
PROTECTION
Series
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
Blue
GND II IV,VI
PROTECTION
Series
ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A
Blue
GND II IV,VI
CORRECT
ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia
CORRECT
mark
N
GND II IV,VI
FAULT
CORRECT
GIN GOUT N
CLASS I+II+III
N
CORRECT
mark
N
FAULT
CORRECT
acdc-dcac@acdc-dcac.eu
CLASS I+II+III
GIN GOUT
CORRECT
N
FAULT
mark
N
CLASS I+II+III
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
CORRECT
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
CORRECT
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
FAULT
CLASS I+II+III
EIGHT PROTECTION STAGES 1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20μs); 22kA (10/350μs) 6. Stage: MOSFET Limiter-500A (8x20μs)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20μs); 20kA (10/350μs)
Series
Blue
mark
GIN GOUT N
N
GIN GOUT
Phone: 389 2 3216 988; Fax: 389 2 3216 993
. . . ACDC DCAC for Your Safety
surge
I (kA) Iimp
100
80
Imax
Wave 8x20μs
40
20
10
Uef
200
100
300
400
500
600
700
800
900
1000
t (μs)
Voltage Spike
U(V) +Uc
Wave 10x350μs
60
Random Noice Destructive Voltage
+ Umax√2 + Umax/√2
5
Safe Power Supply 10
15
20
t (ms)
50Hz Sinusoidal -Uc - Umax√2
Waveform Tracking Filter
Yellow Series
Pink Series
Orange Series
Red Series
ACDC Surge Protector
Blue Series
Protection
Green Series
Surge
Destructive Voltage
Single Phase Application
Three Phase Signal Line
Installation
Hard Wire Plug In
Connection
Series Connection Parallel Connection (Optional) Signal. for Ground Condition
Grounding
Option for ground Filtering No Ground Contamination
Degree of Protection
Eight (8) Stages Surge Protector
*
Three (3) Stages Surge Protector Three Stages Signalization
Signalization
AC Signalization
Products Manufacture by ACDC DCAC Multi-Stage Surge Protection
Signal Line Signalization Modularity Options
Free Contact Alarm Degree of Enclosures IP54, IP65
Standards
IEC61643-1 Class I+II+III; IEC60939-2
IEC61643-21
*
Dane Krapcev no.2/1 1000 Skopje, Macedonia Phone: 389 2 3216 988 Fax: 389 2 3216 993 acdc-dcac@acdc-dcac.eu www.acdc-dcac.eu