GENERAL FLOOR PLAN NOTES
WALL TYPE LEGEND BUILDING AREA CALCULATIONS CONDITIONED 2ND FLOOR 1ST FLOOR
STUCCO ON 2X4 WOOD STUDS
2.
ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF ALL APPLICABLE BUILDING CODES AS WELL AS OTHER LOCAL GOVERNING CODES AND ORDINANCES.
STUCCO ON 2X6 WOOD STUDS
3. 4. 5.
ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF FOUNDATION, FACE OF MASONRY, OR GRIDLINE, UNO. ALL CABINET DIMENSIONS ARE FROM FACE OF FINISH. ALL EXTERIOR WALLS ARE 2 X 4 STUDS AT 16 O.C FIRST FLOOR AND 24 IN O.C. AT 2ND FLOOR, UNO. REF WALL SECTIONS AND STRUCTURAL DRAWINGS.
6. 7. 8. 9.
ALL INTERIOR WALLS ARE 2 X 4 STUDS WITH 1/2" GYP BD EACH SIDE, UNO. INTERIOR WALLS WHERE PLUMBING VENTS OR DRAINS OCCUR SHALL BE 6" STUD CONSTRUCTION. PROVIDE CEMENT BOARD OR PAPERLESS DRYWALL AT ALL SHOWER AND BATH SURROUNDS. REF A2.03 & A2.04 FOR REFLECTED CEILING PLAN AND ELECTRICAL INFO.
INTERIOR WALLS GYP. BOARD ON 2X4 WOOD STUDS
576 SF NON-CONDITIONED 196 SF NON-CONDITIONED 772 SF 3507 SF
Grand total
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE AND CONSTRUCTION CONDITIONS, INCLUDING DIMENSIONS, UTILITY LOCATIONS AND SIZES, AND REPORT ANY DISCREPANCIES TO OWNER AND ARCHITECT.
EXTERIOR WALLS
1209 SF CONDITIONED 1526 SF CONDITIONED 2735 SF
NON-CONDITIONED GARAGE COVERED PORCH
1.
GYP. BOARD ON 2X6 WOOD STUDS 1-HOUR RATED WALL ASSEMBLY 2-HOUR RATED WALL ASSEMBLY
FLOORING FINISH LEGEND
3-HOUR RATED WALL ASSEMBLY
2 A3.03
1 A4.02
WOOD FLOORING
TILE
CONCRETE FLOOR
CARPET
2 A3.02
Z2.11
3
101'-0" 53'-0"
7'-0"
5'-8 1/4"
14'-10 3/4"
REF. 3010 FIXED 3010 FIXED HDR AT CEILING HDR AT CEILING 6'-0"
6'-11 1/4"
8'-9 1/2"
3'-9"
2880 FULL LITE
HDR AT CEILING
3010 FIXED 3010 FIXED HDR AT CEILING HDR AT CEILING
27'-10 1/4"
3'-0"
21'-2"
2'-7 1/4" 2'-8 1/4" 11'-3 1/2"
5'-5 1/2"
BLACKWOOD HOMES
14'-8 1/2"
11'-6"
1'-0" 11'-4 1/4"
?
3
?
3 A3.01
2'-0"
1'-0 1/4"
53'-0"
2'-5"
18'-2"
2'-0"
14'-1 1/4"
38'-8 1/2"
2'-0"
14'-3 3/4"
12'-2 3/4"
11'-11"
62'-2" 1
23'-8 1/2"
Issued Project Number Drawn By Checked By
2016.06.07 01 QAL QAL
Z2.12 Saved: 7/15/2016 1:36:09 PM
F:\Woodlawn\Woodlawn Residence_2.rvt
183 531 SF
9'-9"
3010 FIXED HDR AT CEILING
Z2.12
Room
Z2.12
1120 WOODLAWN AVE
6'-0"
18'-0"
4'-8"
6'-10 1/2"
143 SF
2
6'-10 3/4"
202 SF
DINING 13'-10 3/4"
3'-3"
LIVING ROOM
2880
16'-7 3/4"
2068
3'-0"
3010 FIXED HDR AT CEILING 3016 FIXED HDR AT CEILING
18 SF
5'-2 1/4"
PANTRY
4'-0"
2 A4.01
4'-10"
9'-7 3/4"
4'-10"
168 SF
A3.02
24'-0"
2'-0"
KITCHEN
HDR AT CEILING
197 SF
1
3'-9 3/4"
3'-6"
HALL
3
10'-0 1/4"
2880 FULL LITE
2068
1'-3"
2480
7 SF
2 A4.02
10 1/4" 2'-10 1/2"
WINE
UP
19'-4 1/4"
Z2.11
1'-0"1'-1 3/4" 8 3/4"
31 SF
14'-6"
2'-9 1/4"
2880 FULL LITE
4'-8 3/4"
3'-6"
1'-0"1'-2 1/4"1'-0"
BATHROOM
9'-8"
HDR AT CEILING
9'-4 1/4"
6080 CUSTOM WOOD
36 SF
4'-9 3/4"
28'-11 1/2"
LAUNDRY
6'-0"
2
2880 FULL LITE
7'-0 1/2"
3'-6 1/2"
21 SF
3'-9 1/2"
8'-0"
5'-10"
4'-8"
4080 FULL LITE
222 SF
Room
8'-10 3/4"
2068
5'-11 1/2"
MASTER BEDROOM
4'-0"
6'-0"
CHANGE OF FLOOR MATERIAL UNDER FREE STANDING TUB
Room 12 SF
6'-2 3/4"
19'-2 1/2"
0"
6'-1 3/4"
82 SF
4'-6"
5'-8 1/4"
12'-1 3/4"
MASTER BATH
2'-1 1/4"
4'-10 3/4"
66 SF
4068 SLIDING BARN DOOR
13'-0 1/2"
11'-10 1/4"
CLOSET
131 SF
3016 FIXED HDR AT CEILING 3050 CSMT HDR AT CEILING
3016 FIXED HDR AT CEILING
2068
4'-8"
Z2.11
3016 FIXED HDR AT CEILING
8'-0"
STUDY
24'-3"
3'-3"
11'-10 3/4"
1 A4.01
28'-11 1/2"
3016 FIXED HDR AT CEILING
9'-6 3/4"
3016 FIXED HDR AT CEILING
5'-1 3/4"
2 A3.01
3010 FIXED HDR AT CEILING
9'-11 1/2"
4'-10"
3016 FIXED 3016 FIXED HDR AT CEILING HDR AT CEILING 3016 FIXED 3016 FIXED HDR AT CEILING HDR AT CEILING
23'-10 1/4"
7 1/4"
47'-2"
3010 FIXED 3010 FIXED 3010 FIXED HDR AT CEILING HDR AT CEILING HDR AT CEILING
5'-3 3/4"
2468 POCKET
5 1/4"
24'-0"
N
1
1ST FLOOR PLAN
SCALE: 1/4" = 1'-0"
N
A2.01 1ST FLOOR PLAN
PLAN
TRUE
3" / 12"
GENERAL FLOOR PLAN NOTES 1.
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE AND CONSTRUCTION CONDITIONS, INCLUDING DIMENSIONS, UTILITY LOCATIONS AND SIZES, AND REPORT ANY DISCREPANCIES TO OWNER AND ARCHITECT.
2.
ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF ALL APPLICABLE BUILDING CODES AS WELL AS OTHER LOCAL GOVERNING CODES AND ORDINANCES.
3. 4. 5.
ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF FOUNDATION, FACE OF MASONRY, OR GRIDLINE, UNO. ALL CABINET DIMENSIONS ARE FROM FACE OF FINISH. ALL EXTERIOR WALLS ARE 2 X 4 STUDS AT 16 O.C FIRST FLOOR AND 24 IN O.C. AT 2ND FLOOR, UNO. REF WALL SECTIONS AND STRUCTURAL DRAWINGS.
6. 7. 8. 9.
ALL INTERIOR WALLS ARE 2 X 4 STUDS WITH 1/2" GYP BD EACH SIDE, UNO. INTERIOR WALLS WHERE PLUMBING VENTS OR DRAINS OCCUR SHALL BE 6" STUD CONSTRUCTION. PROVIDE CEMENT BOARD OR PAPERLESS DRYWALL AT ALL SHOWER AND BATH SURROUNDS. REF A2.03 & A2.04 FOR REFLECTED CEILING PLAN AND ELECTRICAL INFO.
3" / 12"
3" / 12"
3" / 12"
GENERAL NOTES ROOF PLAN 6" / 12"
1. 2.
PROVIDE ICE AND WATER SHIELD AT ALL VALLEYS, CRICKETS, AND CATHEDRAL CEILINGS. PROVIDE ONE LAYER 30# FELT UNDERLAYMENT PARALLEL TO RIDGELINE WITH 4" HORIZONTAL OVERLAPS AND 6" STAGGERED VERTICAL END LAPS. START APPLICATION AT LOW POINT AND WORK UP ROOF LAYERING PLIES IN SHINGLE FASHION.
3. 4. 5.
VERIFY LOCATIONS OF GUTTER AND DOWNSPOUTS WITH OWNER. PROVIDE STEP FLASHINGS WHERE THE ROOF INTERSECTS STUCCO WALLS. PROVIDE A MIN. 20 YEAR WARRANTY WITH ROOF. FOLLOW ALL MANUF INSTALLATION INSTRUCTIONS AND PROVIDE OWNER WITH WARRANTY CERTIFICATION SHEET.
6. 7.
MINIMIZE PLUMBING PENETRATIONS TO A MAX OF 3. AIRVENTS SHALL BE THRU THE SOFFIT OR WALL.
6" / 12"
3" / 12"
3" / 12"
Z2.11
WALL MATERIAL TAKEOFF - STUCCO
2
ROOF PLAN
PLAN
N
1 A4.02
2 A3.02
2 A3.03
9625 SF
52'-8 1/2"
TRUE
3737 SF
39'-8"
SCALE: 1/8" = 1'-0" 4'-1 1/4"
3'-0"
13'-0 3/4"
9'-2 3/4"
Exterior - Brick on 2X4 Wd. Stud
23'-4"
3016 FIXED 3016 FIXED HDR AT CEILING HDR AT CEILING 3016 FIXED 3016 FIXED HDR 8' - 6" AFF HDR 8' - 6" AFF
4016 FIXED HDR AT CEILING
4016 FIXED HDR AT CEILING
Exterior -Wood Siding on 2X4 Wd. Stud
6'-2 1/4" 5'-4 1/4"
7'-1 1/2"
8'-7"
BEDROOM 167 SF
CLOSET 37 SF
41 SF
BATHROOM
COVERED PORCH
5'-7 1/2"
2480
3'-2 1/2"
Z2.11
NON-CONDITIONED GARAGE COVERED PORCH
3016 FIXED HDR 8' - 6" AFF 4'-9" 3'-0"
576 SF NON-CONDITIONED 196 SF NON-CONDITIONED 772 SF 3507 SF
2668
2668
106 SF
2668
BATHROOM 43 SF
3'-7 1/4"
3016 FIXED HDR 8' - 6" AFF 3050 CSMT HDR AT CEILING
BEDROOM 107 SF
2668
BATHROOM 42 SF
3016 FIXED 3016 FIXED HDR AT CEILING HDR AT CEILING
28'-8"
39'-5 1/2"
Z2.12
3
INTERIOR WALLS GYP. BOARD ON 2X4 WOOD STUDS
1-HOUR RATED WALL ASSEMBLY 2-HOUR RATED WALL ASSEMBLY 10'-9 1/2"
32 SF
STUCCO ON 2X6 WOOD STUDS
3-HOUR RATED WALL ASSEMBLY
5'-3"
BEDROOM
10'-8 3/4"
CLOSET
32 SF
STUCCO ON 2X4 WOOD STUDS
5'-9 1/4"
CLOSET
8'-6 3/4"
WALL TYPE LEGEND
GYP. BOARD ON 2X6 WOOD STUDS
3016 FIXED HDR 8' - 6" AFF 3016 FIXED HDR AT CEILING
8'-7 3/4"
10'-8 3/4"
10'-3 3/4"
3016 FIXED 3016 FIXED HDR 8' - 6" AFF HDR 8' - 6" AFF 3010 FIXED 3010 FIXED HDR AT CEILINGHDR AT CEILING
A3.02
EXTERIOR WALLS
3/4"
10'-11 1/2"
2680
4'-3"
3016 FIXED 3016 FIXED HDR AT CEILINGHDR AT CEILING 3016 FIXED 3016 FIXED HDR 8' - 6" AFF HDR 8' - 6" AFF
2680
3010 FIXED HDR AT CEILING
16'-4"
16'-3"
3
3010 FIXED HDR AT CEILING
3016 FIXED HDR 8' - 6" AFF 5'-5 1/4"
1'-8"
2680 GLASS
6'-7 3/4"
3016 FIXED HDR AT CEILING 3016 FIXED HDR 8' - 6" AFF
21'-5 1/2"
3016 FIXED HDR AT CEILING 3016 FIXED HDR 8' - 6" AFF
4'-8 1/4" 4'-5 1/4"
2
820 SF
1 3/4" 4'-1" 3'-9 1/2"
3'-0"
20'-1 3/4"
1209 SF CONDITIONED 1526 SF CONDITIONED 2735 SF
202 SF
GAME ROOM LOFT
5'-6 1/4"
3'-3 3/4"
3016 FIXED HDR AT CEILING 3016 FIXED HDR 8' - 6" AFF
UP
11 3/4"
2 A4.01
CONDITIONED 2ND FLOOR 1ST FLOOR
Grand total
3'-0" 3'-3 3/4"
9'-7 3/4" 1 39'-5 1/2"
Z2.11
2680
34 SF
1 A4.01
55 SF 3569 SF 3729 SF 3513 SF 6680 SF 31068 SF
BUILDING AREA CALCULATIONS
13'-2 1/2"
13'-10"
BATHROOM
2680
11'-6 1/4"
2680
3016 FIXED HDR AT CEILING 3016 FIXED HDR 8' - 6" AFF
15'-0"
5'-0"
9'-8"
4'-8 1/4"
Grand total
12'-2 1/4"
09 29 00_GYPSUM WALL BOARD Air Barrier - Air Infiltration Barrier Masonry - Brick - King Size Misc. Air Layers - Air Space Wood - Sheathing - plywood Wood - Siding Wood - Stud Layer
1120 WOODLAWN AVE
N
STUCCO AREA Material: Name 160 SF 07 46 23_WOOD SIDING
BLACKWOOD HOMES
WALL TYPE Exterior - Wood Siding on 2X4 Wd. Stud (special condition)
3
3016 FIXED 3016 FIXED HDR AT CEILING HDR AT CEILING
3050 CSMT HDR AT CEILING 3016 FIXED HDR 8' - 6" AFF 3'-11 3/4"
31'-3" 38'-10"
5'-6 3/4"
3'-0"
5'-3 3/4"
13'-10 1/2" Issued Project Number Drawn By Checked By
00.00.0000 01 waw Checker
1 Saved: 7/15/2016 1:36:10 PM
F:\Woodlawn\Woodlawn Residence_2.rvt
52'-8 1/2"
N
1
2ND FLOOR PLAN
SCALE: 1/4" = 1'-0"
N
Z2.12 PLAN
TRUE
A2.02 2ND FLOOR PLAN & ROOF PLAN
1
THERMOSTAT/HUMIDISTAT LOCATIONS TO BE COORDINATED W HVAC SUBCONTRACOT ND OWNER
2 3
PROVIDE JUMP DUCTS BETWEEN BEDROOMS AND HALLWAY FOR RETURN AIR FLOW VERIFY PROPER LOCATIONS OF PLUMBING & ELECTRICAL STUB OU8TS W/BOH PRIOR TO ROUGH-IN
4
BATHROOM FANS SHALL BE 50 CFM, ENERY STAR LAVELED AND SHALL EXHAUST TO THE OUTDOORS, COMBINE VENT DUCTS WHERE POSSIBLE TO REDUCE EXTERIOR ROOF PENETRATIONS. PLACE VENTS IN SOFFITS WHERE POSSIBLE.
5 6
DRYER VENTS SHALL BE EXHAUSTE DIRECTLY TO THE OUTDOORS WITH RIGID-TYPE DUCT WORK. PROVIDE CATCH PAN UNDER WATER HEATER WITH DRAIN PIPED TO THE EXTERIOR
82 SF
4'-5"
4'-5" 9' - 6"
9' - 6"
PRIOR TO COMMENCEMENT OF WORK, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE AND CONSTRUCTION CONDITIONS, INCLUDING DIMENSIONS, UTILITY LOCATIONS, AND SIZES, AND REPORT ANY DISCREPANCIES TO ARCHITECT AND OWNER
2
ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF ALL APPLICABLE BUILDING CODES AS WELL AS OTHER LOCAL GOVERNING CODES AND ORDINANCES
3
VERIFY PROPER LOCATIONS OF PLUMBING & ELECTRICAL STUB OUTS W/ ALL APPLIANCE MANUFACTURERS PRIOR TO ROUGH IN
4 5 6
ALL DIMENSIONS ARE TO FACE OF WALL FINISH AND CENTERLINE OF FIXTURES, UNO. ALL PANELS SHALL BE RECESSED FLUSH W/WALL FACE ALL SWITCH & OUTLET LOCATION TO BE FIELD VERIFIED W/ OWNER PRIOR TO INSTALLATION. SETUP WALK-THRU MTG SO AS TO NOT DELAY WORK
7 8
CONNECT UNDER CABINET PLUG MOLDS SO AS TO NOT DELAY WORK COORDINATE POER AND WIRING REQUIREMENTS FOR EXHASUT FANS AND MECHANICAL EQUIPMENT AS REQUIRED FOR COMPLETE INSTALLATION
9 10 11 12 13
CENTER FANS AND LIGHT FIXTURES IN THE ROOM IN CLOSETS, LIGHT FIXTURES SHALL BE 12" FROM SHELVES, MIN ALL ELECTRICAL OUTLETS SHALL HVAE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION PREWIRE FOR GARAGE DOOR OPENER IF NOT INSTALLED ELECTRICAL, TELEPHONE AND CABEL SHALL BE UNDERGROUND FROM SERVICE TO HOUSE
EQ
MASTER BEDROOM 9' - 6"
9' - 6"
222 SF
EQ
9' - 6"
2'-10"
EQ
EQ
ELECTRICAL SYMBOL LEGEND
EQ
CIRCUIT LINES
LAUNDRY
ACCENT LIGHT STRIP MOUNTED IN BUILTINS AND CEILING COVE
3624 FIXED
36 SF
19'-0"
BATHROOM
FLOURESCENT FIXTURE
31 SF
1'-6"
ADJUSTABLE RECESSED COMPACT FLUOR. WALL WASHER/SPOT RECESSED COMPACT FLUOR. DOWN LIGHT
HALL
1'-7 1/2"
9' - 6"
197 SF
5'-7"
5'-7"
2'-6"
19'-0"
RECESSED HALOGEN DOWN LIGHT
9' - 6" SURFACE MOUNTED FLUORESCENT LIGHT
9' - 6"
PANTRY 18 SF
1'-0" 1'-0"
168 SF
3'-0"
PENNANT / CHANDELIER
KITCHEN
WALL MOUNTED FLOOD LIGHT W/ PHOTO SENSOR STAIR
DINING
LOW VOLTAGE OR L.E.D. STAIR LIGHT MOUNTED IN WALL 18" ABOVE STAIR TREAD - ALWAYS ON
3'-0"
143 SF
XX"
SURFACE MOUNTED SCONCE/WALL LIGHT AT XX HEIGHT ABOVE FINISH FLOOR
REF.
TRACK LIGHT EXHAUST FAN
EQ
EXHAUST FAN W/ LIGHT
CEILING FAN
BLACKWOOD HOMES
66 SF
EQ
CLOSET
1120 WOODLAWN AVE
131 SF
1
EQ
STUDY
EQ
MASTER BATH
9' - 6"
19'-0"
2'-10"
ELECTRICAL/MECHANICAL NOTES
SMOKE DETECTOR EQ
CARBON MONOXIDE DETECTOR 4
4-WAY SWITCH 3
3-WAY SWITCH D
DIMMER SWITCH LIGHT SWITCH P
8'-0"
EQ
EQ
EQ
PUSH BUTTON
8'-0"
FLOOR DUPLEX OUTLET FLOOR J BOX DUPLEX OUTLET HH
HALF HOT DUPLEX OUTLET
1
XX"
1ST FLOOR REFLECTED CEILING PLAN
DUPLEX OUTLET MOUNTED AT XX HEIGHT ABOVE FINISH FLOOR GFI
SCALE: 1/4" = 1'-0"
GROUND FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET WP
EXTERIOR WATER PROOF DUPLEX OUTLET
220V OUTLET
Issued Project Number Drawn By Checked By
00.00.0000 01 waw Checker
GDO
OUTLET FOR GARAGE DOOR OPENER Saved: 7/15/2016 1:36:11 PM
F:\Woodlawn\Woodlawn Residence_2.rvt
220
N
N
QUADPLEX OUTLET DATA OUTLET
PLAN
TRUE
TELEPHONE OUTLET
A2.03 1ST FLOOR REFELECTED CEILING PLAN
REFLECTED CEILING PLAN NOTES 1. 2.
ALL CEILINGS SHALL BE 5/8" GYP BD. CEILING HEIGHT IS FROM F.F. TO FINISH GYP FACE @ CEILING.
MECHANICAL/PLUMBING NOTES
10'-4"
13'-6 1/4"
13'-5 1/4"
7'-0"
THERMOSTAT/HUMIDISTAT LOCATIONS TO BE COORDINATED W HVAC SUBCONTRACOT ND OWNER
2 3
PROVIDE JUMP DUCTS BETWEEN BEDROOMS AND HALLWAY FOR RETURN AIR FLOW VERIFY PROPER LOCATIONS OF PLUMBING & ELECTRICAL STUB OU8TS W/BOH PRIOR TO ROUGH-IN
4
BATHROOM FANS SHALL BE 50 CFM, ENERY STAR LAVELED AND SHALL EXHAUST TO THE OUTDOORS, COMBINE VENT DUCTS WHERE POSSIBLE TO REDUCE EXTERIOR ROOF PENETRATIONS. PLACE VENTS IN SOFFITS WHERE POSSIBLE.
5 6
DRYER VENTS SHALL BE EXHAUSTE DIRECTLY TO THE OUTDOORS WITH RIGID-TYPE DUCT WORK. PROVIDE CATCH PAN UNDER WATER HEATER WITH DRAIN PIPED TO THE EXTERIOR
ELECTRICAL/MECHANICAL NOTES
4'-0 1/4"
1
PRIOR TO COMMENCEMENT OF WORK, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE AND CONSTRUCTION CONDITIONS, INCLUDING DIMENSIONS, UTILITY LOCATIONS, AND SIZES, AND REPORT ANY DISCREPANCIES TO ARCHITECT AND OWNER
2
ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF ALL APPLICABLE BUILDING CODES AS WELL AS OTHER LOCAL GOVERNING CODES AND ORDINANCES
3
VERIFY PROPER LOCATIONS OF PLUMBING & ELECTRICAL STUB OUTS W/ ALL APPLIANCE MANUFACTURERS PRIOR TO ROUGH IN
4 5 6
ALL DIMENSIONS ARE TO FACE OF WALL FINISH AND CENTERLINE OF FIXTURES, UNO. ALL PANELS SHALL BE RECESSED FLUSH W/WALL FACE ALL SWITCH & OUTLET LOCATION TO BE FIELD VERIFIED W/ OWNER PRIOR TO INSTALLATION. SETUP WALK-THRU MTG SO AS TO NOT DELAY WORK
7 8
CONNECT UNDER CABINET PLUG MOLDS SO AS TO NOT DELAY WORK COORDINATE POER AND WIRING REQUIREMENTS FOR EXHASUT FANS AND MECHANICAL EQUIPMENT AS REQUIRED FOR COMPLETE INSTALLATION CENTER FANS AND LIGHT FIXTURES IN THE ROOM IN CLOSETS, LIGHT FIXTURES SHALL BE 12" FROM SHELVES, MIN ALL ELECTRICAL OUTLETS SHALL HVAE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION PREWIRE FOR GARAGE DOOR OPENER IF NOT INSTALLED ELECTRICAL, TELEPHONE AND CABEL SHALL BE UNDERGROUND FROM SERVICE TO HOUSE
6'-9 3/4"
9' - 6"
BATHROOM 41 SF 9' - 6"
9' - 6" 5'-9"
5'-8 1/2"
5'-10"
7'-9 3/4"
3'-4 1/2"
1'-0" 1'-0"
1'-0" 1'-0"
1'-0" 1'-0"
CLOSET
5'-8 1/2"
8'-3 3/4"
37 SF
9 10 11 12 13
9' - 6"
BEDROOM 167 SF
5'-9"
BATHROOM 34 SF
3'-0"
1'-8 1/4"
2'-8 1/4"
3'-1 3/4"
2'-1 1/4"
9' - 6"
BLACKWOOD HOMES
10'-3 3/4"
6'-3"
8'-0"
12'-2 1/4"
8'-8 1/2"
6'-4"
7'-9 1/4"
9' - 6"
GAME ROOM LOFT
5'-1 1/2"
5'-2 1/4"
9' - 6"
9' - 6"
BEDROOM 107 SF
EQ
5'-1 1/2"
1'-0" 1'-0"
1'-11 3/4"
2'-9" 10'-1 3/4"
7'-4 3/4"
820 SF
EQ
1'-0" 1'-0"
9' - 6"
9' - 6"
BATHROOM 5'-10" 9' - 6"
106 SF
BATHROOM
5'-2 1/4"
5'-2 1/4"
EQ
9' - 6"
BEDROOM
8'-0 1/2"
EQ
6'-5 1/2"
5'-2 1/4"
43 SF
1120 WOODLAWN AVE
6'-8"
1
1'-0" 1'-0"
1'-0" 1'-0"
42 SF
1'-0" 1'-0"
1'-0" 1'-0"
1
11'-3 1/2"
8'-11"
11'-0 1/2"
Issued Project Number Drawn By Checked By
2ND FLOOR REFLECTED CEILING PLAN
00.00.0000 01 WAW Checker
SCALE: 1/4" = 1'-0" Saved: 7/15/2016 1:36:12 PM
F:\Woodlawn\Woodlawn Residence_2.rvt
4'-8"
N
PLAN
N
TRUE
A2.04 2ND FLOOR REFELECTED CEILING PLAN
3 A3.01
3 A3.01
2 A4.01
1 A4.01
2ND FLOOR PLAN MODEL 11' - 7 1/8"
2ND FLOOR PLAN MODEL 11' - 7 1/8"
1ST T.O.P. 10' - 0"
1ST T.O.P. 10' - 0"
1ST FLOOR PLAN MODEL 0' - 0"
1ST FLOOR PLAN MODEL 0' - 0"
2
FRONT ELEVATION
REAR ELEVATION
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0" 2 A3.03
2 A3.02
1 A4.02
2 A4.02 2ND TOP - RAFTERS 21' - 1 1/8"
1120 WOODLAWN AVE
1
2ND TOP - RAFTERS 21' - 1 1/8"
BLACKWOOD HOMES
2ND TOP - RAFTERS 21' - 1 1/8"
2 A3.01
2ND FLOOR PLAN MODEL 11' - 7 1/8"
1ST FLOOR PLAN MODEL 0' - 0"
Saved: 7/15/2016 1:36:14 PM
F:\Woodlawn\Woodlawn Residence_2.rvt
1ST T.O.P. 10' - 0"
Issued Project Number Drawn By Checked By
06/17/16 01 Author Checker
Z2.11 3
LEFT ELEVATION
SCALE: 1/4" = 1'-0"
ELEVATIONS
3 A3.01
2 A4.01
1 A4.01
2 A3.01
2 A4.01
3 A3.01
2ND TOP - RAFTERS 21' - 1 1/8"
2ND FLOOR PLAN MODEL 11' - 7 1/8"
1ST FLOOR PLAN MODEL 0' - 0"
2
1ST FLOOR PLAN MODEL 0' - 0"
GARAGE REAR ELVATION
3
SCALE: 1/4" = 1'-0"
GARAGE FRONT ELEVATION
SCALE: 1/4" = 1'-0"
1 A4.02
2 A3.02
2 A3.03
2 A4.02
2ND TOP - RAFTERS 21' - 1 1/8"
1120 WOODLAWN AVE
1ST T.O.P. 10' - 0"
1ST FLOOR RCP MODEL 9' - 6"
BLACKWOOD HOMES
1ST T.O.P. 10' - 0"
2ND FLOOR PLAN MODEL 11' - 7 1/8"
2ND FLOOR PLAN MODEL 11' - 7 1/8" 1ST T.O.P. 10' - 0"
Saved: 7/15/2016 1:36:16 PM
F:\Woodlawn\Woodlawn Residence_2.rvt
1ST FLOOR PLAN MODEL 0' - 0"
1
RIGHT ELEVATION
SCALE: 1/4" = 1'-0"
Issued Project Number Drawn By Checked By
06/17/16 01 Author Checker
Z2.12 ELEVATIONS