Archer Catalogue

Page 1

IS 900 Insert - Charcoal

THE WORLD’S MOST EFFICIENT GAS LOG SPACE HEATERS WITH THE HIGHEST ENERGY STAR RATING!


Introducing the most efficient gas log space heater on the market Please read this brochure carefully and discover why Archer Gas Log Space Heaters are superior to other gas log space heaters on the market today. Also notice the beautiful design that will add style and value to your home. The Archer heater range with its 5.4 to 5.7 energy star rating is today the world leader in modern day gas heating technology. Its classic beautiful styling and the natural look of a gas log fire will complement any home decor. The Archer Heater has achieved the ultimate in efficiency and high heat output to give you the most superior product available on the market today to heat your home. All Models are available for natural gas and LPG installations.

Energy Star Rating... Energy Star Rating represents an industry wide independent Rating that indicates how efficiently a heater operates. The more Energy Stars, the greater the efficiency. The Archer Gas Log Space Heater range with it’s 5.4 - 5.7 Energy Star Rating, is the highest Star rated product available in the world today. With it’s high Energy Star Rating and heating transfer efficiency, the Archer Gas Log Space heater range has the capacity to heat areas 18 squares ( 180m2 ) to 25 squares ( 250m2 )* No other Gas Log Space Heater range on the market today can match this claim. Read the facts and discover why the Archer range has created a revolution in modern, efficient, cost saving in home space heating. *NOTE: Heating capacity may vary depending on heater model selection, climate, home design, heater location, ceiling height and insulation etc.

Heater Comparison The Mj input of a heater should not be used for comparing the products heat output and heating capacity. The Kw heat output and efficient heat transfer is the only true method of product comparison. Example: A 30 Mj heater with a 5.7 Energy Star rating has a larger heat output than a 30 Mj 3 star energy rated heater.

Graph shows a simplified visual of actual laboratory testing.

3 Star Rating Heater IS 905 Stainless Steel Insert

New Log set for IS900 as of May/June 2017

Graph shows a simplified visual of actual laboratory testing.

Archer 5.7 Star Rating Heater

3


Revolutionary Patented Triple Heat Exchanger International Patent No PCT/AU2007/0011459 The secret of the Archer revolutionary 5.4 - 5.7 energy star performance is the patented triple heat exchanger that puts more heat into your home and money in your pocket instead of up the chimney. The Archer Gas Log Space Heater has shattered the boundaries of acceptable product design. The basis of the incredible leap in high heat output and high efficiency achieved by the Archer Gas Log Fire is the revolutionary heat exchange system which extracts 92% + heat from the incoming gas which is directly transferred into your home. The Archer Gas Log Fire does not only feature a burning system that looks realistic, but also incorporates a combustion process which delivers high efficiency and high heat output. (Beauty - Efficiency - Heat) After engaging in an extensive research and development program of many years, Aurora have developed an innovative high efficiency heat exchange system which has amazed the industry and has achieved the highest appraisal from independent heating authorities for its innovative design and efficiency. The Archer’s high efficiency 3 stage high performance heat exchange system, allows for the heat of the incoming combustible gases to be squeezed to 55ºC before they enter the flue resulting in total combustion, to ensure that every megajoule of gas input energy available is put to work for heating the home. This type of process of achieving high performance heat output has to date not been achieved by any other similar appliance, but with an Archer heater it is reality and you get the benefit.

HOT AIR TO HOME

Doing our share for the environment with 92% combustion efficiency... Any advance in reduction of greenhouse gases is a small step forward to preserve the environment and the standard of living for future generations. We are committed to reduce pollution (greenhouse gases) Aurora has ensured that one of the major beneficiaries will be the environment. The Archer heater range not only extracts 92% of the heat from the gas, it also spreads it better through your home. Combustion efficient clean burn, super efficient heat exchanger and 55ºC flue exhaust temperature, generates fewer greenhouse gases (CO-CO2) per megajoule of heat produced, when compared to other similar conventional gas heaters, which is a direct benefit to the environment.

THIRD STAGE

FIRE BOX IS 750 Insert Flat Front with Beach Fire Log Set - Color Charcoal

VI RO NM ENT

AURORA

E MAT SYST LI

S EM

FIRST STAGE

COLD AIR IN

C

SECOND STAGE

C OM EN MIT TED TO THE

5


Operating and Safety Features Computer Controlled Safety and Efficiency Hot Surface Ignition (H.S.I.) Module

The Archer’s solid state electronic computer control system, gives you safety, convenience and efficiency not seen in Australia before. To start with the Archer electronic solid state module controls every function and operating feature of the heater for safe and efficient operation. During operation the independent twin H.S.I. ignition system controls the ignition cycle of each burner automatically to ensure trouble free automatic ignition (no pilot light or troublesome piezo ignition) for added reliability, safety and lower gas bills.

Bay Window Safety Grill

During operation the remote flame sensors constantly monitor the status of the flame for added safety. Archer’s independent (H.S.I.) ignition system lets you select from 3 burner settings. Low, medium and high burn at the touch of a button from easy accessible controls for selection of your own comfort level and lowest operating cost. Years of painstaking laboratory testing coupled with extensive in field trials have resulted in a truly reliable ignition system. Prior to start up of your heater it automatically purges any un-burnt gas prior to ignition for added safety.

Standard Safety Grill - Flat Front

The 3 speed fan which is automatically linked to each burner setting has been customised for optimum comfort and efficiency. The fan in the heater will not start operating until the heater has sufficiently warmed up. When you turn your heater off the fan will keep pushing warm air until all the built up heat in the heater has been extracted. All your heaters operating modes can be viewed on the display monitor located behind the bottom front panel. Additional safety features such as flame failure safety, overheating safety, automatic shutdown if power or gas fails and fan start/stop protection are all built into the Archer solid state electronic module for customising your heater for added safety, optimum comfort and efficiency to give you the comfort of feeling safe in your home.

Zero Clearance Installation Another direct installation and safety feature derived from the Archer’s revolutionary heat exchange system, is the zero clearance temperature achieved on the bottom, top, back and sides only of the heater, which allows the heater to be installed safely against combustible materials. The safety screen fitted to the large neo ceramic door glass will be welcoming news for parents with small children.

IS 755 Stainless Steel Insert

Simple ON/OFF operation

Thermostat Control *All heaters are available with optional fully programmable remote thermostat.

7


Integrated Central Ducted Heating Designed for total house coverage, uniform heat distribution throughout the whole house. Introducing the most efficient Archer gas log fireplace heaters which are now available as a central heating fireplace system to heat your whole home. Archer’s central heating system for its models IS900 and IS700 extracts 93% of available heat generated by Archer’s revolutionary triple heat exchange system and distributes that heat into different areas within your home. Providing quiet and efficient heating. 93% of heat available from your fireplace is efficiently distributed through the ducting system by an inline duct fan through ceiling or floor ducts located throughout your home. Heating requirements for your home can be automatically adjusted by Archer’s simple control system, allowing you to control the heat you require from your fireplace and ducting system. Archer’s central heating fireplace system has the flexibility through its revolutionary PVC fluing system that the fireplace can be installed anywhere in your home. There is a variety of options available for wall, floor or ceiling outlets for your ducting system, which you can choose to suite your home décor.

Inline Fan Placement The inline fan can be installed either vertically or horizontally and must be installed 6 metres from the fire. The inline fan can be suspended from framing members with provided springs and bracket to reduce the possibility of fan noise through vibration. Typical fan placement are either roof, cavity or under floor. IS 700 Heating Capacity - 3 Ducts Number of Ducts

Approx. Maximum Kw

1

2.65

2

2.29

3

2.30

Ducting The design as illustrated are examples only and can be fitted and installed as per individual requirements. Number of Ducts

IS900

IS700

Recommended

5

3

Maximum up to*

8

5

Fluing Two basic types of flue configuration can be used either horizontal, co axial flue or single 40mm PVC fluing system for more technical information see page 27 of this brochure for flue installations.

IS 900 Heating Capacity - 5 Ducts

IS 905 Stainless Steel Insert

Number of Ducts

Approx. Maximum Kw

1

1.94

2

1.67

3

2.46

4

1.67

5

1.35

*Performance is subject to length of ducts, ceiling heights and house insulation.

9


Ducting Construction

Wall Cavity

Warm air from heater ducted to outlets Ă˜ 250mm

6 Metres to Inline Fan

Ducting System, Off-Take and Fireplace

Warm air from heater ducted to outlets Ă˜ 250mm

6 Metres to Inline Fan

Finished Installation

FS 100 Color Charcoal

11


FS 700 With Beach Fire Log Set - Color Charcoal

FS 101 Color Metallic Brown with Gold Door and Optional Pedestal

13


stallation

0/IS200

Installation Advantages Low cost versatile installation. The Archer Gas Log Space Heater technology eliminates costs and flexibility on installations when compared to the installation of most other gas heaters, which require expensive and unsightly flue installations. The Archer’s revolutionary plastic power flue and plastic 40mm Ø PVC single 12 flue system eliminates those costly installations and is ideal for high rise apartments, external and internal wall applications anywhere in your home and ideally can be used as a replacement for existing gas or oil space heaters. 6 The Archer Gas Log Space Heater due to its high efficiency with 92% heat 97 extracted from Archer’s revolutionary 5 3 heat exchanger ensures that surface 1 temperatures of the heater are kept 4 extremely low to allow zero clearance installations without the added cost of

installing a zero clearance box, which allows you to create your own decorative fireplace at the lowest cost. The PVC co-axial flue system will give you the added benefit of using external combustion air allowing the air in your home to remain fresh. Whilst the 40mm PVC single flue system gives you unlimited installation advantages. See installation section on page 23 to discover how the Archer Gas Log Space Heater can be installed in your choice of location of existing masonry fireplace, external and internal wall applications, high rise apartments and created zero clearance fireplaces all due to the small bore PVC co-axial or single flue system available only with an Archer heater.

11 11 11

44 5100 Max.

99

44

66

33 325 317

See page 23 for flue installation options

Automatic Humidifier Standard Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe 05 40mm 45º PVC elbow (not supplied) 06 40mm 90º PVC elbow 07 50mm Ø flexible pipe (includes adaptors) 08 65mm Ø PVC co-axial pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 10 Zero clearance installation to combustibles 11 Flashing (not supplied) 12 Mantel (not supplied)

Most gas heaters dry out the air in the room. Remember the bowls of water in front of the old gas heaters?

The Archer has ingeniously solved this problem with an automatic humidifier. Gas contains moisture which is normally expelled out the flue or chimney after combustion, but the Archer is so efficient by taking 92% of the heat out of the burnt gases that the moisture drops out and condenses in the back of the heater.

Vertical Top Flue Installation

Suit Models FSP600

500

Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe 05 40mm 45º PVC elbow (not supplied) 06 40mm 90º PVC elbow 07 50mm Ø flexible pipe (includes adaptors) 08 65mm Ø PVC co-axial pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 10 Zero clearance installation to combustibles 11 Flashing (not supplied) 12 Mantel (not supplied)

This water is collected in a tank which is then pumped up to a stainless steel holding tank where it evaporates in the stream of hot air, which is blowing into your home. Air humidity is automatically restored. This feature is especially important for those with delicate throats or mild breathing difficulties.

Back View

Note: The amount of condensate build up depends on outside temperature, humidity levels, length of flue and heat settings. Long single vertical flue, will cause the automatic humidifier to activate more often, compared to short horizontal coaxial or single flue installations.

FSP 600 Free Standing Top Flued Heater - Color Charcoal

15


IS 750 Insert Flat Front Single Burner with Glass - Color Charcoal

FS 700 Free Standing Single Burner Flat Front with Glass - Colour Black

17


Beautiful Mantel Options

Select traditional or contemporary designs to suit your style Aurora Climate Systems has a range of Mantel options available which complement your Archer heater, available in Corner Mantels or Full Mantels with, or without Mantel Base. Colors available - White, Dark Oak, Cherry and Unfinished. Suits Model Series 700 and Model IS 100/200 inserts.

IS 700 Insert Flat Front - Color Charcoal with Optional Corner Mantel Model MC-W Color- White with Optional Corner Mantel Base, Model MCB-W - Color White

IS 203C Deep Fireplace Insert. Powder Coated - Color Rivergum with Chrome Door Optional IS 002PC Small Surround Shown with Optional Full Mantel MC-CH - Color Cherry and Opt. MCB-CH Mantel Base.

19


IS 704 Insert Flat Front - Color Charcoal Shown with Stainless Door and Optional IS007, 3 Sided Surround Shown with Full Mantel Model MW-DO - Color Dark Oak and Opt. MWB-DO Mantel Base.

IS 203C Deep Fireplace Insert. Powder Coated - Color Hunter Red with Gold Door and Optional IS 002PC Small Surround and Optional MW-DO - Dark Oak Mantel

21


Optional Heater Surrounds

Mantel Specifications 80 1070

FULL WALL MANTLE BASE

Optional Mantel Finishes:

1070

Select from traditional or contemporary designs to suit your style

CORNER MANTLE TOP

730

1500

125 220

1300

1200

220

White

1300 680

Unfinished

750

1090 670

750

1090

80

670

180

Light Dark Oak

1130

590.5

730

70

1. Flat Front bolted Surround available in Stainless Steel or Charcoal Dimensions: H 694 W 949 D 15mm

550

CORNER MANTLE BASE

80

70

1110

1200

220 180

Cherry

Colours to Suit Your Home DĂŠcor

Select from our optional range or we can customise your colour selection Archer offer a choice of six optional colours as shown below, that cover neutral and traditional colour themes. If you require a colour that doesn’t appear in our optional selections, our manufacturing facility allows us to customise your colour selection to your specific requirements. Please consult with your dealer to establish a formal quotation for this customised service.

Powder Coat Finishes

2. Flat Front with 3 sided Surround available in Stainless Steel or Charcoal Dimensions: H 742 W 885 D 7mm

Additional colours available on request

RiverGum

Silver Pearl

Hunter Red

Metallic Brown

Charcoal

Pewter

Paint Finishes

3. Standard Surround available in two sizes for Bay Window Heater. Small: H 758 W 900 D 25mm Large: H 858 W 1110 D 25mm

23


Technical Specifications

Model Model Model Model Model FS101 FSP600 Model Model Model Model Model FS101 FSP600 FS100 Description Description FS101 FS101 FSP600 FSP600 FS100 Model Description Free Standing Free Standing Free Standing Free Standing Free Standing Heater with Pedestal Free Standing Heater with Pedestal Description Description Description DescriptionDescription FSC100 n DescriptionDescription Free Standing with Pedestal Free Standing Heater with Pedestal Free Standing Heater Specification KeyFree Standing Specification KeyFree Description Heater Free Pedestal Standing with Pedestal Heater withHeater Pedestal Standing Heater Free Standing with Pedestal Heater with Pedestal ng Heater Free Standing Heater with Top Flue Flat Front with Key1 Flue Outlet (outside Key Heater Key 1 Flue Outlet (outside Console 65mm, inside 40mm) Specification 65mm, inside 40mm) Specification , inside 40mm) Specification Specification Key Specification Key Specification Key Specification Key on Key Specification Key 1 Flue Outlet (outside 65mm, inside 40mm) 1 Flue Outlet (outside 65mm, 1 Flue Outlet (outside inside1 40mm) Specification Keyinside 40mm) 2inside Air 65mm, Inlet 2 Air Inlet Flue Outlet (outside 1 Flue 65mm, Outlet (outside inside 40mm) 65mm, inside 40mm) 1 Flue Outlet (outside 1 Flue 65mm, Outlet (outside inside 40mm) 65mm, inside 40mm) et (outside 1 Flue 65mm, Outlet (outside inside 40mm) 65mm, 40mm) 3 Electric Cord 2 Air Inlet 3 Electric Cord 2 Air Inlet 2 Air Inlet 2 Air Inlet 2 Air Inlet 2 Air Inlet 1 Flue Outlet (outside 65mm, inside 40mm) 2 Air Inlet 2 Air Inlet 3 Electric Cord 4 1/2” BSP Connection 3 Electric Cord 3 Electric Cord 4 1/2” BSP Connection 2 Air Inlet (inside) (inside) e) 3 Electric Cord 3 Electric Cord 3 Electric Cord 3 Electric Cord 3 Electric Cord ord 4 1/2” BSP Connection (inside) 4 1/2” BSP Connection (inside) 4 1/2” BSP Connection (inside) 3(inside) Electric Cord 5 Air Inlet Cover Plate 5 Air Inlet Cover Plate 4 1/2” BSP Connection 4 1/2” BSP (inside) Connection (inside) 4 1/2” BSP Connection 4 1/2” BSP (inside) Connection Connection 4 1/2” BSP (inside) Connection (inside) 4 1/2”Plate BSP Connection (inside) 5 Air Inlet Cover 6Plate 5 Air Inlet Cover 5 Air Inlet Cover Plate 6 90º/40mm PVC Elbow 90º/40mm PVC Elbow 5 Air Inlet Cover 5 Plate Air Inlet Cover Plate 5 Air Inlet Cover 5 Plate Air Inlet Cover Plate over5Plate Air Inlet Cover Plate 5 Air Inlet Cover Plate 90º/40mm 90º/40mm 90º/40mm Flexible PVC Pipe Flexible PVC Pipe 6 90º/40mm PVC6 Elbow 90º/40mm6 PVC Elbow PVC7Elbow 6 90º/40mm PVC6 Elbow 90º/40mm6 PVC Elbow PVC Elbow m PVC6 Elbow 90º/40mm6 PVC Elbow PVC 7Elbow 6 90º/40mm PVC Elbow 7 Flexible 7 Flexible 7 Flexible 8 Heater Surround7 Flexible (see page 09 Pipe for options)PVC 8 Heater Surround7 Flexible (see page 09 Pipe for options)PVC 09 Pipe for options)PVC PVC 7 Flexible Pipe PVC Pipe PVC 7 Flexible Pipe PVC Pipe VC 7 Flexible Pipe PVC Pipe 7 Flexible(see PVC Pipe09 for options) 8 Heater Surround (see page 09 for options) 8 Heater Surround 8 Heater Surround (see page 09 for options) Flue 6” (150mm) Flue 6” (150mm) mm) 8 Heater Surround 8 Heater (see page Surround 09 for(see options) page9 09 forLocating options)Ring 8 Heater Surround 8 Heater (see page Surround 09 for(see options) 09 forpage options) rround 8 Heater (see page Surround 09 for(see options) page909 for Locating options) Ring 8page Heater Surround (see page 09 for options) 9 Flue Locating Ring 6” (150mm) 9 Flue Locating Ring 6” (150mm) 9 Flue Locating Ring 6” (150mm) 9 Flue Locating 9 Ring Flue6”Locating (150mm)Ring 6” (150mm) 9 Flue Locating 9 Ring Flue6”Locating (150mm)Ring 6”9(150mm) ting 9 Ring Flue6”Locating (150mm)Ring 6” (150mm) Flue Locating Ring 6” (150mm)

Model Model Model Insert - Shallow & Deep FSC100 FSC100 IS100/200 Description Description Description Console Console Heater Heater Inset Heater Specification Specification Key Key Key Specification 1 Flue 1 Flue Outlet (outside (outside 65mm, 65mm, inside inside40mm) 40mm)40mm) 1Outlet Flue Outlet (outside 65mm, inside 2 Air 2 AirInlet 2Inlet Air Inlet 3 Electric 3 Electric Cord CordCord 3 Electric 4 1/2” 4 1/2” BSPConnection Connection (inside) (inside) 4BSP 1/2” BSP Connection (inside) 5 Air 5 AirInlet CoverCover Plate Plate Plate 5Inlet AirCover Inlet 6 90º/40mm 6 90º/40mm PVC PVCElbow ElbowElbow 6 90º/40mm PVC 7 Flexible 7 Flexible PVC PVCPipe Pipe Pipe 7 Flexible PVC 8 Heater 8 Heater Surround Surround (see (seepage page 09forforoptions) options) 8 Heater Surround (see09page 09 for options) 9 Flue 9 Flue Locating Ring Ring6”Ring 6”(150mm) (150mm) 9Locating Flue Locating 6” (150mm)

Model Model Model IS100/200 IS100/200 IS700 Description Description Description Inset Inset Heater Heater Flat Front Heater Specification Specification Key KeyKey Specification 1 Flue 1 Flue Outlet (outside (outside 65mm, 65mm, inside inside 40mm) 40mm) 1Outlet Flue Outlet (outside 65mm, inside 40mm) 2 Air 2 Air Inlet 2Inlet Air Inlet 3 Electric 3 Electric Cord Cord 3 Electric Cord 4 1/2” 4 1/2” BSP Connection Connection (inside) (inside) 4BSP 1/2” BSP Connection (inside) 5 Air 5 Air Inlet Cover Plate Plate 5Inlet AirCover Inlet Cover Plate 6 90º/40mm 6 90º/40mm PVC PVC Elbow Elbow 6 90º/40mm PVC Elbow 7 Flexible 7 Flexible PVC PVC Pipe PipePipe 7 Flexible PVC 8 Heater 8 Heater Surround Surround (see (see page page 0909 forfor options) options) 8 Heater Surround (see page 09 for options) 9 Flue 9 Flue Locating Ring Ring 6” 6” (150mm) (150mm) 9Locating Flue Locating Ring 6” (150mm)

Bolted Surround

Model Model

Flat IS700 IS700Front 3 Sided Surround Description Description Flat Flat Front Front Heater Heater Specification Specification Key Key 1 Flue 1 Flue Outlet Outlet (outside (outside 65mm, 65mm, inside inside 40mm) 40mm) 2 Air 2 Air Inlet Inlet 3 Electric 3 Electric Cord Cord 4 1/2” 4 1/2” BSP BSP Connection Connection (inside) (inside) 5 Air 5 Air Inlet Inlet Cover Cover Plate Plate 6 90º/40mm 6 90º/40mm PVC PVC Elbow Elbow 7 Flexible 7 Flexible PVC PVC Pipe Pipe 8 Heater 8 Heater Surround Surround (see (see page page 0909 forfor options) options) 9 Flue 9 Flue Locating Locating Ring Ring 6”6” (150mm) (150mm)

162

62 162

162

162

162

25 25

2

2

3

2

2

1

28 2

3

1 3 1 189 3 1 3 4 106 189 4 189 189 63 4 105 4 106 317 106 106 63 105 63 63 317 706 706 706

162

162

162

162

28 2

25

25

162

162

1 283

283

3

4 402

326

317283

326

25 2

9

3

3

4 402 317

317

1

3 1

402 4 326

28 2

28 2

283

1 326

9

4024 325 283 1

317

25 2

25 1 2

9

28

4

402

4

283

325 283

325

25

7 8

8257 7 8 430 430

161

7

8 87 7

7 7

430430

2 2 608

3

402 283

7

2828

2

3

1

3

4 1 325 402 325 283

317

25 2

7

257

161

3

402 4 317

25 162 8162

7

162

402 326

6

1 1

638

3 3 4 4

C/L FLUE SINGLE 105 325 325 CONNECTOR TYPE

402 402 326 326 283 283 Shallow Insert Model

608

608 608 6 6 C/L FLUE C/L FLUE C/L FLUE SINGLE 105 105 150 SINGLESINGLE 105 150 CONNECTOR CONNECTOR CONNECTOR TYPE TYPE TYPE Shallow Insert Model 6

630 630 638

630 630

608 608 66 C/L C/LFLUE FLUE SINGLE SINGLE 150 105 105 150 CONNECTOR CONNECTOR TYPE TYPE

695 695

695

695

725

700

716 716

716

716

716

700

716

716

700

638

858

845 858

30 30

30

443

25

30 30 8 3025 78 8 128 290 430 430

128

5

608

Deep Insert Model

30 443

695 443

30

443

30

443

795

725

695

695 30

700

443

443

30

700

E C/L FLUE 105 CO-AXIAL AL 435 TYPE

C/L FLUE CO-AXIAL 105 TYPE 435

5

5 C/L FLUE CO-AXIAL TYPE 105 435

5 C/L FLUE CO-AXIAL TYPE

325 435

325

C/L FLUE CO-AXIAL TYPE 220

443

443

2 2

443

150

150

1

443

443

C/L FLUE CO-AXIAL 1 TYPE

1

2 325 C/L SINGLE FLUE 220SINGLE C/L C/L SINGLE 220 220 CONNECTOR FLUE 325 FLUE TYPE CONNECTOR CONNECTOR 435 325TYPE 220 325 TYPE 435

325

758/858

5

C/L FLUE CO-AXIAL TYPE

435 150

5

5

435

443

C/L FLUE CO-AXIAL TYPE

C/LC/L FLUE FLUE CO-AXIAL CO-AXIAL TYPE TYPE

325

5 5

220 485

445 220

220

Large Surround 1110 x 858 Small Surround 900 x 758 485 485

443

6 C/L SINGLE GLE C/L SINGLE FLUE 105FLUE 105 150 150 CONNECTOR 435 CTOR CONNECTOR TYPE TYPE 435

435

6 C/L SINGLE 150 325 FLUE CONNECTOR TYPE

435

6

C/L SINGLE C/L SINGLE FLUE FLUE 150 150 CONNECTOR CONNECTOR TYPE 325220 325 TYPE 220

1

583 150

9 583

325 220 TOP VIEW 435

435

162 162 162

162

1

583

9

66 109

220

C/L SINGLE FLUE 1 9 150 CONNECTOR 325 TYPE 66 109

31 TOP VIEW

6 C/L SINGLE 6 FLUE CONNECTOR TYPE

6

435 435

716

TOP VIEW

31

6 6

325

31 445

220485

SPECIFICATION KEYS: 1 Flue Outlet Co-axial (outside 65mm, inside 40mm) single flue 40mm Ø. Flexible Flue 40mm Ø. 2 Air Inlet 3 Electric Cord 4 1/2” BSP Connection (inside) 6 90º/40mm PVC Elbow 7 Flexible PVC Pipe 8 Heater Surround (see page 19 for options) 9 Flue Locating Ring 6” (150mm).

189 63 106

1 44

105 105 105 706 706 706

706

66 109

11

3 4

162 162

28 28 28

2

C/LC/L SINGLE SINGLE 1 FLUE FLUE 150 150 CONNECTOR CONNECTOR 105 325 325 TYPE TYPE

150

3 Sided 3 Sided Surround Surround H. H. 742 742 x W. x W. 885 885 x D. x D. 7mm 7mm 4 Sided 4 Sided Surround Surround H. H. 840 840 x W. x W. 885 885 x D. x D. 7mm 7mm

443 443

583

716

706 706

706 3 Sided 3 Sided Surround Surround H. 742H. x 742 W. 885 x W.x 885 D. 7mm x D. 7mm Large4Surround 1110 x 858 Small 900 x 758 Sided 4 Sided Surround Surround H. 840 H.x 840 W. Surround 885 x W.x 885 D. 7mm x D. 7mm

28

6 C/L SINGLE 6 FLUE CONNECTOR 105TYPE 150

742 742

649 706 706

440 583

8 8

325 325

2325

583

443

443

885 885

8 8 8 694 742 758/858

716

6

C/L C/LFLUE FLUE CO-AXIAL CO-AXIAL 105 105 TYPE TYPE

440

5 5

630 630

55

949 885 900 /1110

3030 900 /1110 443 443

30

700 443

795 795

8

5

608 608

C/L FLUE C/L FLUE C/L FLUE CO-AXIAL 105 105 105 CO-AXIAL TYPE CO-AXIAL TYPE TYPE Deep Insert Model

105

77

88 430 430

630 638 630

5 5 5 608 608 608

638

3030

7

706

706

695

443

858 858 C/L FLUE CO-AXIAL TYPE

858 858

706

30716 716 8

716

716

858

858

710

290

858 858

795 795

716 716

638

795

4

22

2

33

3

189 189 189 106 106 63 63 63 106

2828 2 2 1 1

3 3 4 4

105 105

189 189 106 106 6363

706 706

485 485

SPECIFICATION KEYS: 1 Flue Outlet Co-axial (outside 65mm, inside 40mm) single flue 40mm Ø. Flexible Flue 40mm Ø. 2 Air Inlet 3 Electric Cord 4 1/2” BSP Connection (inside) 6 90º/40mm PVC Elbow 7 Flexible PVC Pipe 8 Heater Surround (see page 19 for options) 9 Flue Locating Ring 6” (150mm).

25


IS 900 / 905 Specifications: IS 900 Charcoal Picture Frame Surround

Flue & Installation Options

IS 905 All Stainless Steel or Charcoal Bolted Surround

1137

External Wall

Internal Wall

Created Fireplace

To suit all Archer Heater models.

Created Fireplace

Created Fireplace

1247 11

1

11

1

500

500

4

742

IS 700 & IS 900 Fireplace can be installed above floor level

752

4

6 *B

IS 700 Fireplace can be installed at floor level and IS 900 min 30mm above floor level

*C

5

10

5100 max 12

5100 Max.

12 10

12

*A

703 703

703

6

6

3

3

8

8 1 11

995

1

11

500

4

25

484

25

1

1137

146 146

4

61

146 146

10

12

666

12

C/L 12 5100 Max. C/L Single Single FlueFlue Connection Connection

10

900 / 905 rear view 22

12

742

1

7

159 159 108

6

3

5100 Max.

3

4

86

3

468 468

3

4

3

3

1500 20 20

666

484

Specification Key Side 66 Wall Installation 01 Single cowl (stainless steel) Specification Key Created External Wall Suit Models Specification Key 02 Fireplace Co-axial cowl (stainless steel) Single cowl (stainless steel) Created Fireplace 01 External Wall

IS700/FS100/FSC100/IS100/IS200 Suit Models03 1/2” (12.7mm) Ø BSP gas connection (flexible) 01 Single cowl (stainless steel) Co-axial cowl (stainless steel) 02 Suit Models IS700/FS100/FSC100/IS100/IS200 02 Co-axial cowl (stainless steel) 04 40mm Ø PVC pipe 1/2” (12.7mm) Ø BSP gas connection (flexible) 03 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 05 40mm 45º PVC elbow (not supplied) IS700/FS100/FSC100/IS100/IS200 40mm Ø PVC pipe 04 04 40mm Ø PVC pipe 06 40mm 90º PVC elbow 05 40mm 45º PVC elbow (not supplied) 05 40mm 45º PVC elbow (not supplied) 07 50mm Ø flexible pipe (includes adaptors) 40mm 90º PVC elbow 06 06 40mm 90º PVC elbow 08 65mm Ø PVC co-axial pipe 50mm Ø flexible pipe (includes adaptors) 07 07 50mm Ø flexible pipe (includes adaptors) 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 65mm Ø PVC co-axial pipe 08 4 08 65mm Ø PVC co-axial pipe 10 Zero clearance installation to combustibles 6” (150mm) Ø Outer decorative flue pipe (not supplied) 09 5 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 11 Flashing (not supplied) Zero clearance installation to combustibles 10 10 Zero clearance installation to combustibles 12 Mantel (not supplied) Flashing (not supplied) 11 11 Flashing (not supplied) Mantel (not supplied) 12 12 Mantel (not supplied) 4 10

1

666

681

5

C/LCoaxial Coaxial C/L FlueFlue

8

8

7

4 10

3

3

2

7

8 4

6

108 3

3 97

6

3

317

11

97

Internal - Vertical 11

11

1

2

108

2

6

30

20

Masonry External Wall Flue

Masonry Internal Flue

Masonry Externa

5

4

5100 max

10

80 150

8 2

4

3

5100 max

10

9

150

4

6

4 8

6

4

6

6

4

3

105

6

97

3

3

105 97

5 1

6 6

3

6

3

1

97

6 3

5

3 3

327

97

500

Masonry External Wall Flue

Masonry Internal Flue

12

2

97

500

11

4

10

327

1 1

11

Specification Key Specification Key 01 Single cowl (stainless steel) 01 Single cowl (stainless steel) Specification Key Specification Key Suit Models Suit Models Specification Key Specification Key 02 Co-axial cowl (stainless steel) 02 Co-axial cowl (stainless steel) 01 Single cowl (stainless steel) 01 Single cowl (stainless 5 steel) IS700/FS100/FSC100/IS100/IS200 IS700/FS100/FSC100/IS100/IS200 Suit Models03 1/2” (12.7mm) Ø BSP gas connection (flexible) Suit Models03 1/2” (12.7mm) Ø BSP gas connection (flexible) 01 Single cowl (stainless steel) 01 Single cowl (stainless steel) 02 Co-axial cowl (stainless steel) 02 Co-axial cowl (stainless steel) Suit Models Suit Models 4 IS700/FS100/FSC100/IS100/IS200 IS700/FS100/FSC100/IS100/IS200 02 Co-axial cowl (stainless steel) 02 Co-axial cowl (stainless steel) 04 40mm Ø PVC pipe 04 40mm Ø PVC pipe 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 03 1/2” (12.7mm) Ø BSP4 gas connection (flexible) IS700/FS100/FSC100/IS100/IS200 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 05 40mm 45º PVC elbow (not supplied) 05 40mm 45º PVC elbow (not supplied) IS700/FS100/FSC100/IS100/IS 04 40mm Ø PVC pipe 04 40mm Ø PVC pipe 04 40mm Ø PVC pipe 04 40mm Ø PVC pipe 06 40mm 90º PVC elbow 06 40mm 90º PVC elbow 05 40mm 45º PVC elbow (not supplied) 05 40mm 45º PVC elbow (not supplied) 5100 Max. 9 5 05 40mm 45º PVC elbow (not supplied) 05 40mm 45º PVC elbow (not supplied) 07 50mm Ø flexible pipe (includes adaptors) 07 50mm Ø flexible pipe (includes adaptors) 5100 06 40mm 90º PVC elbow 06 Max. 40mm 90º PVC elbow 12 06 40mm 90º PVC elbow 06 40mm 90º PVC elbow 08 65mm Ø PVC co-axial pipe 08 65mm Ø PVC co-axial pipe 10 07 50mm Ø flexible pipe (includes adaptors) 07 50mm Ø flexible pipe (includes adaptors) 07 50mm Ø flexible pipe (includes adaptors) 07 50mm Ø flexible pipe (includes 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 4 adaptors) 08 65mm Ø PVC co-axial pipe 08 65mm Ø PVC co-axial pipe 80 08 65mm Ø PVC co-axial pipe 08 65mm Ø PVC co-axial pipe 10 Zero clearance installation to combustibles 10 Zero clearance installation to combustibles 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 150to combustibles 11 Flashing (not supplied) 11 Flashing (not supplied) 10 Zero clearance installation to combustibles 10 Zero clearance installation 5100 Max. 5100 Max. 10 Zero clearance installation to combustibles 10 Zero clearance installation to9combustibles 12 Mantel (not supplied) 12 Mantel (not supplied) 11 Flashing (not supplied) 11 Flashing (not supplied) 10 11 Flashing (not supplied) 11 Flashing (not supplied) 12 12 Mantel (not supplied) 12 Mantel (not supplied) 12 12 Mantel (not supplied) 12 Mantel (not supplied) 80 10

6

500

4

Side Wall Installation

3

3 97

97

Masonry Internal Flue

2

4

1 500

80

C/L Coaxial C/L COAXIAL FLUE Flue

3 8

1

11

500

Specification Key

01 Single cowl (stainless steel) Side5 Wall Installation 02 Co-axial cowl (stainless steel)

Top Flue FSP600

1 500

1

150

4

28 34

6

97

11

4

1

666

4

900 / 905 Side view

97

752

2

3

105

105

Under Floor

External Wall

1

FS100/FSC100/IS100/IS200 Suit Models03 1/2” (12.7mm) Ø BSP gas connection (flexible) 01 Single cowl (stainless steel) Co-axial cowl (stainless steel) Suit Models FS100/FSC100/IS100/IS200 02 Co-axial cowl (stainless steel) 04 40mm Ø PVC pipe 1/2” (12.7mm) Ø BSP gas connection (flexible) 4 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 05 40mm 45º PVC elbow (not supplied) FS100/FSC100/IS100/IS200 40mm Ø PVC pipe 04 40mm Ø PVC pipe 06 40mm 90º PVC elbow 40mm 45º PVC elbow (not supplied) 5100 Max. 5 07 50mm Ø flexible pipe (includes adaptors) 05 40mm 45º PVC elbow (not supplied) 40mm 90º PVC elbow 10 06 40mm 90º PVC elbow 08 65mm Ø PVC co-axial pipe 50mm Ø flexible pipe (includes adaptors) 07 50mm Ø flexible pipe (includes adaptors) 0980 6” (150mm) Ø Outer decorative flue pipe (not supplied) 65mm Ø PVC co-axial pipe 08 65mm Ø PVC co-axial pipe 10150 Zero clearance installation to combustibles 6” (150mm) Ø Outer decorative flue pipe (not supplied) 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 11 Flashing (not supplied) Zero clearance installation to combustibles 5100 Max. 10 Zero clearance installation to combustibles 12 Mantel (not supplied) Flashing (not supplied) 10 11 Flashing (not supplied) Mantel (not supplied) 12 Mantel (not supplied)

8

3

15 15 97

3 325

500

03 1/2” (12.7mm) Ø BSP gas connection (flexible) 02 Suit Models /FSC100/IS100/IS200 04 40mm Ø PVC pipe 03 05 40mm 45º PVC elbow (not supplied) IS700/FS100/FSC100/IS100/IS200 04 06 40mm 90º PVC elbow 05 07 50mm Ø flexible pipe (includes adaptors) 06 08 65mm Ø PVC co-axial pipe 07 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 5100 Max. 08 10 Zero clearance installation to combustibles 09 11 Flashing (not supplied) 10 12 Mantel (not supplied) 11 12 5100 Max.

97

97

4 3

3 6

0 108

500

Specification Key Created Fireplace External Wall 611 01 Single cowl (stainless steel) Specification Key d Internal Suit Models Specification Key 02 Fireplace Co-axial cowl (stainless steel) Wall Single cowlWall (stainless steel) Created Fireplace 01 Internal

8

634

30

8

317

8 4 3 2

7

3

6

97

500

25 25

3

1

97

342 342

484

7

7

4

317

2 97

4

6

11

1

4

5

7

4 1

4 1

1

484

Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe 05 40mm 45º PVC elbow (not supplied) 06 40mm 90º PVC elbow 07 50mm Ø flexible pipe (includes adaptors) 08 65mm Ø PVC co-axial pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied) 10 Zero clearance installation to combustibles 11 Flashing (not supplied) 12 Mantel (not supplied)

4

5100 Max.

5

8

108

500

4 5100 Max.

5

6 6

4

97

995 995

5100 max

5

666 752 8

33

97

634

2

Suit Models IS700/FS100/FSC100/IS100/IS200

C/L

2

6

97

150

742

Created Fireplace Internal Wall

Suit Models IS700/FS100/FSC100/IS100/IS200 Notes *450mm Depth for internal flue installation *600mm Depth for external flue installation

8

2

15

681 681 666 666

1

Framing for Created Fireplace

C/L Single Single Flue Flue Connection Connection

12

44

4

3

1

1

6

97

484

97 105

500

7 7

7 7

3

30

15 15

66

10

7

703 703

5

1

500 500

3 97

Masonry External

1

500

1247 1247

105

Masonry Internal

Side Wall

30 30

995 995

500

4

5

5100 Max.

Clearance Dimensions *Model I.S. 700 - A. w= 760 B. h= 655 C. d= 580 *Model I.S. 900 - A. w= 1050 B. h= 715 C. d= 630

484 484

484

500

8 4 2

7

7

327

325 327

3 3

317

325 317

97

4 4

3

5

200

1

SPECIFICATION KEYS: 1 Flue Outlet Co-axial (outside 65mm, inside 40mm) single flue 40mm Ø. Flexible Flue 40mm Ø. 2 Air Inlet 3 Electric Cord 4 1/2” BSP Connection (inside) 6 90º/40mm PVC Elbow 7 Flexible PVC Pipe 8 Heater Surround. Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl Suit(stainless Models steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) IS700/FS100/FSC100/IS100/IS200 04 40mm Ø PVC pipe 05 40mm 45º PVC Specification Key elbow (not supplied) 06 PVC elbow steel) 01 40mm Single90º cowl (stainless Suit 07 50mm Ø flexible pipe (includes 02 Models Co-axial cowl (stainless steel) adaptors) IS700/FS100/FSC100/IS100/IS200 08 Ø PVC co-axial 03 65mm 1/2” (12.7mm) Ø BSPpipe gas connection (flexible) 09 (150mm) Ø Outer 04 6”40mm Ø PVC pipe decorative flue pipe (not supplied)

Masonry Internal Flue

Masonry Internal Flue

External Wall Specification Key Flue

Suit Models 01 Single cowl (stainless steel) FS100/FSC100/IS100/IS200 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe Specification Key 05 40mm 45º PVC elbow (not supplied) 01 Single cowl (stainless steel) 06 40mm 90º PVC elbow Suit Models 02 Co-axial cowl (stainless steel) 07 50mm Ø flexible pipe (includes adaptors) FS100/FSC100/IS100/IS200 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 08 65mm Ø PVC co-axial pipe 04 40mm Ø PVC pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied)

External Wall Flue

Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl Suit(stainless Models steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) IS700/FS100/FSC100/IS100/IS200 04 40mm Ø PVC pipe 05 40mm 45º PVC Specification Key elbow (not supplied) 06 PVC elbow steel) 01 40mm Single90º cowl (stainless Suit 07 50mm Ø flexible pipe (includes 02 Models Co-axial cowl (stainless steel) adaptors) IS700/FS100/FSC100/IS100/IS200 08 Ø PVC co-axial 03 65mm 1/2” (12.7mm) Ø BSPpipe gas connection (flexible) 09 (150mm) Ø Outer 04 6”40mm Ø PVC pipe decorative flue pipe (not supplied)

Masonry External Wall Flue

Masonry External Wall Flue

Internal Wall Specification Key Installation / Vertical Flue

Suit Models 01 Single cowl (stainless steel) FS100/FSC100/IS100/IS200 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe Specification Key 05 40mm 45º PVC elbow (not supplied) 01 Single cowl (stainless steel) 06 40mm 90º PVC elbow Suit Models 02 Co-axial cowl (stainless steel) 07 50mm Ø flexible pipe (includes adaptors) FS100/FSC100/IS100/IS200 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 08 65mm Ø PVC co-axial pipe 04 40mm Ø PVC pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied)

Internal Wall Installation / Vertical Flue

SPECIFICATION KEYS: 1 Single Cowl 2 Co-axial Cowl 3 1/2” (12.7mm) Ø BSP gas connection (flexible) 4 40mm Ø PVC pipe 5 40mm 45º PVC elbow (not supplied) 6 40mm 90º PVC elbow 7 50mm Ø flexible pipe 8 PVC co-axial pipe 65mm Ø 40 mm Ø inner 9 6” (150mm) Ø Outer decorative flue pipe. 10 Zero clearance installation to combustibles 11 Flashing. 12 Mantel. 4

Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl Suit(stainless Models steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) FS100/FSC100/IS100/IS200 04 40mm Ø PVC pipe 05 40mm 45º PVC Specification Key elbow (not supplied) 06 PVC elbow steel) 01 40mm Single90º cowl (stainless Suit 07 50mm Ø flexible pipe (includes 02 Models Co-axial cowl (stainless steel) adaptors) FS100/FSC100/IS100/IS200 08 Ø PVC co-axial 03 65mm 1/2” (12.7mm) Ø BSPpipe gas connection (flexible) 09 (150mm) Ø Outer 04 6”40mm Ø PVC pipe decorative flue pipe (not supplied)

External Wall Flue

External Wall Flue

Under Floor Installation

Specification Key Suit Models 01 Single cowl (stainless steel) IS700/FS100/FSC100/IS100/IS200 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe Specification Key 05 40mm 45º PVC elbow (not supplied) 01 Single cowl (stainless steel) 06 40mm 90º PVC elbow Suit Models 02 Co-axial cowl (stainless steel) 07 50mm Ø flexible pipe (includes adaptors) IS700/FS100/FSC100/IS100/IS200 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 08 65mm Ø PVC co-axial pipe 04 40mm Ø PVC pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied)

Under Floor Installation

Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl Suit(stainless Models steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) FS100/FSC100/IS100/IS200 04 40mm Ø PVC pipe 05 40mm 45º PVC Specification Key elbow (not supplied) 06 PVC elbow steel) 01 40mm Single90º cowl (stainless Suit 07 50mm Ø flexible pipe (includes 02 Models Co-axial cowl (stainless steel) adaptors) FS100/FSC100/IS100/IS200 08 Ø PVC co-axial 03 65mm 1/2” (12.7mm) Ø BSPpipe gas connection (flexible) 09 (150mm) Ø Outer 04 6”40mm Ø PVC pipe decorative flue pipe (not supplied)

Internal Wall Installation / Vertical Flue

Internal Wall Installation / Vertical Flue

Vertical Top Flue Installation

Specification Key Suit Models 01 Single cowl (stainless steel) FSP600 02 Co-axial cowl (stainless steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 04 40mm Ø PVC pipe Specification Key 05 40mm 45º PVC elbow (not supplied) 01 Single cowl (stainless steel) 06 40mm 90º PVC elbow Suit Models 02 Co-axial cowl (stainless steel) 07 50mm Ø flexible pipe (includes adaptors) FSP600 03 1/2” (12.7mm) Ø BSP gas connection (flexible) 08 65mm Ø PVC co-axial pipe 04 40mm Ø PVC pipe 09 6” (150mm) Ø Outer decorative flue pipe (not supplied)

Vertical Top Flue Installation

Specification Key 01 Single cowl (stainless steel) 02 Co-axial cowl Suit(stainless Models steel) 03 1/2” (12.7mm) Ø BSP gas connection (flexible) IS700/FS100/FSC100/IS100/IS200 04 40mm Ø PVC pipe 05 40mm 45º PVC Specification Key elbow (not supplied) 06 PVC elbow steel) 01 40mm Single90º cowl (stainless Suit 07 50mm Ø flexible pipe (includes 02 Models Co-axial cowl (stainless steel) adaptors) IS700/FS100/FSC100/IS100/IS200 08 Ø PVC co-axial 03 65mm 1/2” (12.7mm) Ø BSPpipe gas connection (flexible) 09 (150mm) Ø Outer 04 6”40mm Ø PVC pipe decorative flue pipe (not supplied)

Under Floor Installation

Under Floor Installation

27


Specifications

Specifications Model Series 3

Freestanding and Insert

Model Series 9

Insert Flat Front

Input

Nat/LPG High 30Mj/h

Input

Nat/LPG High 45 Mj/h

Nat/LPG Medium 20Mj/h

Nat/LPG Medium 25Mj/h

Nat/LPG Low 10Mj/h

Nat/LPG Low 20 Mj/h

Output

High Kw 7.6 Med 5.2 Kw Low 2.5 Kw

Output

High 11.2 Kw Med 8.2 Kw Low 5 Kw

Combustion Efficiency

92%

Combustion Efficiency

90%

Fan

Automatic 3 speed

Fan ( Dual )

Automatic 3 speed

Ignition

Automatic H.S.I.

Ignition

Automatic H.S.I.

Heat Settings

3 Settings - High/Medium/Low

Heat Settings

3 Settings - High/Medium/Low

Automatic Humidifier

Standard

Atomatic Humidifier

Standard

Heating Areas*

Up to 180 square meters (18 squares)*

Heating Areas*

Up to 250 square meters (25 squares)*

Clearances*

Zero clearance to all surfaces**

Clearances

Zero clearance to all surfaces**

Energy Star Rating

5.5

Energy Star Rating

5.4

Tested to A.G.A. Code AS4553 - 2008 Certificate No. 5446

Tested to AGA Code AS4553 - 2008 Certificate No 13368

Specifications

Specifications

Model Series 7 Input

Insert Flat Front and Freestanding

Model Series 720

Insert and Flat Front Single Burner

Nat/LPG High 30Mj/h Nat/LPG Medium 18Mj/h

Input

20Mj/h

Nat/LPG Low 12Mj/h

Output

5.5 Kw

Output

High Kw 7.6 Med 4.6 Kw Low 3 Kw

Combustion Efficiency

92%

Combustion Efficiency

92%

Fan

Automatic 3 speed

Fan

Automatic 3 speed

Ignition

Automatic H.S.I.

Ignition

Automatic H.S.I.

Heat Settings

5 Settings

Heat Settings

3 Settings - High/Medium/Low

Automatic Humidifier

Standard

Automatic Humidifier

Standard

Heating Areas

Up to 100 square meters (10 squares)*

Heating Areas*

Up to 180 square meters (18 squares)*

Clearances

Zero clearance to all surfaces**

Clearances

Zero clearance to all surfaces**

Energy Star Rating

5.9

Energy Star Rating

5.7

Tested to AGA Code AS 4553 - 2008 Certificate No 8198G

Tested to AGA Code AS 4553 - 2000 / AG 103 - 2000 AS 5601 - 2004 Approval No. GSCS 20025 Note * Heating Capacity may vary depending on heater model selection and to climate, home design, heater location, ceiling height, and insulation etc. Note** Heater clearances: Insert models Series 3, 7 & 9 require minimum clearance of 25mm side and top for easy removal of appliance.

Head Office: AURORA CLIMATE SYSTEMS 71-73 Overseas Drive NOBLE PARK VICTORIA 3174 telephone. 61 3 9795 8895 facsimile. 61 3 9701 2088 e-mail. sales@auroraclimatesystems.com.au web. www.auroraclimatesystems.com.au

The Archer Warranty Aurora Climate Systems stands behind their products and gives every purchaser this guarantee. Heat Exchanger

5 years parts/1 year labour

Main Fan

2 years parts/1 year labour

Flue Fan

2 year parts/1 year labour

All other parts

2 year parts/1 year labour

Glass

Accidental breakage of glass excluded.

Please Note: Flame pattern displayed may vary depending on gas type used, flue type and flue length. Product specifications are subject to change without notice. Aurora Climate Systems, Copyright Š 2013 all rights reserved.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.