Burner Riello WA o813 88 666 204

Page 6

Two Stage Gas Burners

Gas Series

GAS TRAINS Fuel can be supplied either from the right or left hand sides. The gas train can be selected to best fit system requirements depending on the fuel output and pressure in the supply line. The gas train can be “Multibloc “ type (containing the main components in a single unit) or “Composed” type (assembly of the single components).

Example of the gas train connection flange of GAS/2 burners.

MULTIBLOC GAS TRAIN WITHOUT SEAL CONTROL

11 4

P1

MULTIBLOC

7

10

13

9

8

P2

6

5

3

P3

L

2

1

L1

MULTIBLOC GAS TRAIN WITH SEAL CONTROL

1

Gas input pipework

2

Manual valve

3

Anti-vibration joint

4

Pressure gauge with pushbutton cock

5

Filter

6

Pressure regulator (vertical)

7

Minimum gas pressure switch

8

VS safety solenoid (vertical)

9

10

VR regulation solenoid (vertical) Two settings: - firing output (rapid opening) - maximum output (slow opening) Gasket and flange supplied with the burner

11

Burner

12

13

Seal control mechanism for valves 8-9. According to standard EN 676, the seal control is compulsory for burners with maximum output above 1200 kW. Gas train-burner adapter

P1

Combustion head pressure

11 4

P1

MULTIBLOC

7

10

P2 Pressure downstream from the regulator

13

9

12

8

P2

6

5

P3

3

L

2

P3 Pressure upstream from the filter

1

L

L1

Gas train supplied separately, with the code given in the table Installer’s responsibility

L1

COMPOSED GAS TRAIN WITHOUT SEAL CONTROL

COMPOSED GAS TRAIN WITH SEAL CONTROL

11

11 4 P1

7

10

13

9

8

P2

L

6

4

P1

7

10

6

5

P3

3

2

L1

1

13

9

12

8

P2

L

6

5

P3

3

2

L1

1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.