s u s p e n s e
f e a r
a state or feeling of excited or anxious uncertainty about what may happen
a n unpl ea s a nt em ot ion cau s ed by t he bel i ef t hat s om eon e or s o m et hi ng i s da ngero u s , likely to c a u s e p a i n , o r a t h fr ee aa rt
A l f r e d
H i t c h c o c k ’ s
“ R e a r
W i n d o w ”
1
2
3
4
5
6
7
8
9
10
{ architectural }
f e a r
cockroaches needles snakes spiders evil enclosed spaces heights tunnels clowns loneliness
1 2 3 4 5 6 7 8 9 10
1
2
6
7
1 2 3 4 5 6 7
3
4
5
time distance thoughts isolation expectation test flaw
s u s p e n s e
1
1 2 3 4 5
i n
2
unknown loneliness evil death heights
t h e
f i l m
4
3
5
C O N C E P T U A L
D E V E L O P M E N T
s i n i s t e r
w h i m s i c a l
m a s s
c o r r u p t
t r a n s f o r m a t i o n
h i d d e n
i n
p l a i n
s i g h t
e s c a l a t i n g
c y c l e
s t u d y
f o r m
d e v e l o p m e n t
R a c h e l ,
N V
0’
10’
20’
40’
0’
10’
20’
d i s c o v e r y
b a c k s t o r y
a n t i c i p a t i o n
f e a r
o f
t h e
u n k n o w n
f e a r
o f
l o n e l i n e s s
f e a r
o f
e v i l
s i t e
a n a l y s i s
t h e m e d
i n t e r i o r s
1 2 3 4
. . . .
P P P R
a h a a
s s o t s s i n
i v e o v o i v e w a t
1.
2.
3.
4.
C o o l i n g l t a i c P a n e l s S o l a r I l l u m i n a t i o n e r C o l l e c t i o n
NE
SW
NW
SE
4 FLASHING IN COLD PROCESS ADHESIVE
2
TREMCO WHITE ROCK-IT REFLECTIVE FLOOD COAT WITH WHITE AGGREGATE 3 PLIES OF TREMCO COMPOSITE PLY ADHERED WITH SOLVENT FREE BURMASTIC
6
1/2" FIREBOARD ADHERED WITH FAST N FREE ADHESIVE 2.0" ISOCYANURATE INSULATION ADHERED WITH FAST N FREE ADHESIVE 2.5" ISOCYANURATE INSULATION MECHANICALLY FASTENED
3
2.5" ISOCYANURATE INSULATION MECHANICALLY FASTENED VAPOUR BARRIER THERMAL BARRIER
5
METAL DECK TYP WALL STEEL FRAME LIGHT WELL LOUVERS CONCRETE SLAB VAPOR BARRIER CRUSHED STONE
1
RAINWATER ESCAPE COMPACTED FILL DRAINAGE PIPE
7
0’
5’
10’
REFER TO SPECIFIC DETAILS FOR REGLET FLANGE CONFIGURATIONS
CONT STRIP OF SELF HEALING UNDERLAYMENT
CONT TERMINATION BAR
SHEET METAL TWO PIECE REGLET AND COUNTERFLASHING SYSTEM
WIND CLIPS ROOFING MEMBRANE
WIND CLIPS AT 30"
5/8" ROOF COVER BD
SEMI RIGID INSULATION, 8' MIN HEIGHT 2"
OC MAX OR
SHEET METAL TWO PIECE REGLET AND COUNTERFLASHING SYSTEM
OC
TREATED WOOD NAILER
PRECAST CONCRETE PANEL
SEALANT
MIN
6" STL STUDS AT 16" OC MAX
SHIM AS NEEDED
1"
BRACING AT 48" OC VERTICALLY
R19 BATT INSULATION
3 4"
RO
2" MIN
10"
CONT 6" WIDE 20 GA GALV SHEET METAL BACKER PLATE
4" CONT STRIP OF SEMI RIGID INSULATION
FASTENERS WITH ANCHOR DISCS AT 6"
3 4"
SEALANT
AS SCHEDULED
SEALANT WITH BACKER ROD
TREATED 3/4" PLYWOOD
10" MIN
CEILING SYSTEM
GASKETED FASTENERS AT 12" OC SHEET METAL COPING
2"
CONT CLEAT
6" MTL STUDS
ALUMINUM WALL SYSTEM ANCHOR
SLOPE
3"
R19 BATT INSULATION PRECAST CONCRETE PANEL
1'-2"
1X CONT TREATED WOOD BLOCKING
5"
STUD BRACING AT
RIBBON WINDOW AT 48" OC. GUAGE TO MATCH METAL STUDS
PROVIDE CONT 6" WIDE X 20 GA STRAP AT CONDITIONS WHERE STEEL STUDS WITH 5/8" ROOF COVER BOARD UNITS IS USED 221"
2"
1"
7"
PERIMETER FIRE CONTAINMENT SYSTEM GLAZED ALUMINUM WALL SYSTEM
ROOF SYSTEM 7"
6
HEA D D E TA I L AT G L A Z E D A LUM INUM WA LL SYST E M T YP
4
3 4"
PRECAST CONCRETE PANEL GYP BD GUTTER ABOVE
GYP BD
R19 BATT INSULATION
4" CONT STRIP OF SEMI RIGID INSULATION
R19 BATT INSULATION
PRECAST CONCRETE PANEL
6" MTL STUDS
EDGE OF LIQUID APPLIED FLASHING
3
6"
ROOF DRAIN SUMP
1'-0" SET DRAIN ELEV 1" BELOW SUMP PERIMETER
BEGINNING OF 1"/FT [1:12mm] SLOPE TAPERED INSULATION ROOFING SYSTEM
SLOPE
SEALANT
GLAZED ALUMINUM WALL SYSTEM
2"
S I L L D E TAI L AT G L A Z E D A LUM INUM WA LL SYST E M
ROOF DRAIN ASSEMBLY
FILL WITH MINERAL WOOL INSULATION 2"
STUD BRACINT AT RIBBON WINDOW CONDITIONS AT 48" OC GUAGE TO MATCH STUDS 7"
2" X 20 GA CONT METAL STRAP
SEALANT WITH BACKER ROD
4" WIDE CONT STRIP OF SEMI RIGID INSULATION
3 4"
SHIM AS NEEDED
RO
RO
2"
6" MTL STUDS
ALUM SILL PAN FINISHED TO MATCH GLAZED ALUM WALL SYSTEM
2"
SEALANT WITH BACKER ROD
5
FLAS H ING SYST EM DETA IL TYP
WALL BEYOND
SILL PAN END DAM BEYOND
ALUMINUM WALL SYSTEM ANCHOR
2
P REC AST CONC R ET E DETAI L BIT UMINOUS ROOFING T YP
7" GLAZED ALUM WALL SYSTEM
2"
JA MB DETAIL AT GLAZED ALUMI NUM WALL SYST EM
PIPE INSULATION EXTEND 2'-0' BELOW SLAB
1
DR AIN S UMP S EC T I ON D ETA IL TY P
8
PRECAST PANEL PRESSURE EQ CAVITY INTERIOR FINISH AIR PRESSURE BARRIER VAPOUR BARRIER ANCHOR AIR PRESSURE SEAL FIRESTOP SYSTEM COMP. CORRUGATED METAL DECK LINE OF FINISH FLOOR STEEL BEAM CLIP ANGLE SPANDREL GIRDER CLADDING FASTENER
0’
5’
10’
7"
SPRAYED FIRE
CONT 22 GA MIN 3" STRU C T U R AL DEEP C A SE ST UD IES LEG
RESISTIVE MATERIAL
DEFLECTION TRACK ATTACH TO Z CLIP AT 16" BEAM FLANGE
OC MAX
1 2"
WALL WITH MINERAL WOOL
3/4"
INSULATION CONT 2" WIDE X 22 GA METAL STRAP -
DOUBLE SEALANT AT ALL JOINTS - TYP
BD OR STUDS TO
8" WIDE CONT FOILED FACED MINERAL WOOL VERTICAL STRIP AT ALL
DEFLECTION TRACK IN
JOINTS
SPRAY APPLIED FIRESTOP MATERIAL EACH SIDE - MIN 1/2" OVERLAP AT BEAM AND METAL FLOOR/ROOF DECK
8
INS ULAT ED PR EC AST CONC R ET E PANEL T YP
SPRAYED FIRE RESISTIVE MATERIAL
CONT 22 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO Z CLIP AT 16"
BEAM FLANGE
OC MAX
BEYOND
FILL GAP BETWEEN DECK/BEAM AND TOP OF WALL WITH MINERAL WOOL INSULATION CONT 2" WIDE X 22 GA METAL STRAP ATTACH
GYP BD TO
STRAP AT 8"
MIN.
PARALLEL TO FLUTES
1 2"
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF
CONTINUOUSLY FOIL TAPE INSULATION TO BACK OF PRECAST
INSULATED PRECAST CONCRETE PANEL
2"
OC MAX
THIS AREA
3/4"
STRAP AT 8"
DO NOT ATTACH GYP
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN
1"
GYP BD TO
1"
ATTACH
ALL PANEL EDGES TO HAVE CONCRETE RETURN (NO EXPOSED INSULATION)
3 4"
2"
DECK/BEAM AND TOP OF
MIN.
BEYOND
FILL GAP BETWEEN
OC MAX
THIS AREA SPRAY APPLIED FIRESTOP MATERIAL
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PARALLEL TO FLUTES
EACH SIDE - MIN 1/2" OVERLAP AT BEAM AND METAL FLOOR/ROOF DECK
7
H EAD OF WALL PART I T I ON DETAIL T YP
150’ 19’-6”
55’
55’
19’-6”
9’
19’-6”
55’
55’
19’-6”
C
19’-6”
19’-6”
9’
9’
150’
F
G
55’
55’
D 30° 150’
H
150’
E
55’
55’
K
B
A
I
19’-6”
19’-6”
J
L N M
M
N
A B C D E F G H I J
Setting Introduction Investigations Maintenance Mechanical Storage Passenger Entry Passenger Exit Photo Lab Retail
K L M N
0
D I M E N S I O N
P L A N
Stock Room Grounds Shed Restaurant Kitchen
25’
50’
75’
0
E G R E S S
P L A N
25’
50’
75’
0
F U R N I T U R E
P L A N
25’
50’
75’
COST ESTIMATE - LIFE CYCLE COSTS PART 1 - INITIAL BUILDING COSTS (Including material costs, labor, overhead and profit) 1.1 125,037 ft2 (Square footage of building) x $175.00 (cost based on 2016 figures for the Nevada region) = $21.9 million 1.2 A.
LUMP SUM – Supply, Support and Structure of Themed Amusement Park Ride Lump sum dark roller coaster $25,000,000
1.3 Life cycle costs – Project consists of sustainable construction with clean energy support in the form of: • Solar Panels Photovolatic panels on the roof to mitigate operating costs • Wind Energy • Natural Ventilation; Evaporative Air Cooling • Water collection, reservoir and reuse The amusement park will be open seasonally, from April-November, and will include energy systems in each ride-attraction, as well as wind generators in the parking areas. It is assumed that the systems provided will generate the energy needed for the months when the park is in active operation. On off months, the park will continue to generate energy to be stored and shared on a grid with the surrounding region.
1.4 Calculations for THRC and daily profits
Ride Vehicle Capacity 2 people per row 4 people per vehicle 4 vehicles per train 7 trains =112 people Ride Duration 5 min ride 2 min load 7 min combined =8.5 cycles per hour Theoretical Hourly Rate Capacity = 960 people Cost of ticket = $20.00 Income per hour =$19,200 Income per day assuming 9:00 am - 9:00 pm schedule =$230,400 Monthly Income =$5,229.200
SECTION 092000 PLASTER AND GYPSUM BOARD PART 1 - GENERAL PART 2 - PRODUCTS 2.1 MANUFACTURER/PRODUCTS A. Fire-Resistance Rated Gypsum Board 1. Basis of Design: National Gypsum Company; Gold Bond® BRAND Fire-Shield® Gypsum Board. 2. Basis of Design: National Gypsum Company; Gold Bond® BRAND Fire-Shield C™ Gypsum Board. 2.2 FIRE-RESISTANCE RATED GYPSUM BOARD A. Type X, Panel Physical Characteristics 1. Core: Fire-resistant rated gypsum core 2. Surface paper: 100% recycled content paper on front, back and long edges 3. Long Edges: Square 4. Overall thickness: 5/8 inch 5. Panel complies with requirements of ASTM C 1396, Type X B. Type C, Panel Physical Characteristics 1. Core: Enhanced fire-resistance rated gypsum core 2. Surface paper: 100% recycled content paper on front, back and long edges 3. Long Edges: Square 4. Overall thickness: 5/8” 5. Panel complies with requirements of ASTM C 1396, Type X PART 3 - EXECUTION 2.3 Coordinate Preparation and Installation requirements with the desired partition, ceiling or floor assembly.
v e h i c l e
c o n c e p t
ROLLERCOASTER TRUSS
S P I R A L F L O O R P L AT E
SHEAR CORE and INTERIOR COLUMNS
STEEL FRAME
EXTERIOR ENVELOPE
f i n a l
e x h i b i t i o n