WALL SYSTEM Exterior Angle Aluminum profile used to make exterior up to 90 degrees with wall panels corner for internal wall.

Corners for Internal Wall Aluminum element used to make interior corners up to 90 degrees with wall panels. Offered in widths of 10 x10 cm and 15 X 15 cm according to the project layout.

To facilitate the unpacking of the wall panels and the juncture of the panels the total height of the corner form is divided into two sections: the panel for the lower part can be unpacked once the wall panels are removed to be used next. The higher part is taken out after removing the wall panel joint.

7


WALL SYSTEM Cross Corner

Wall Corner

The cross ensemble is a made up of four wall corners. It is connected with clips and stays like all the other panels.

“L” Corner The ensemble or “L” corner is made up of four pieces:

Exterior Angle Wall Corner

• A wall corner. • An exterior angle. • Two panels of equal width to the thickness of the wall plus the wall corner. These pieces are connected by clips and stays.

“T” Corner The “T” ensemble is always made up of three pieces: • Two wall corners. • A wall panel of equal width to the thickness of the wall plus 2 EQM. These pieces are connected with clips and stays. • The fronts and exterior sections of housing can be made up in two options: with CAP panels plus standard wall panels or with high panels. 88

Wall Corner


WALL SYSTEM The fronts and exterior sections of housing can be made up in two options: with CAP panels plus standard wall panels or with high panels.

CAP Panels

High Panels

Serves to compliment the standard panels to finish the total height of the exterior wall holding the thickness of the total panel. The advantage of using this type of configuration lays in the utilization of the standard panel which can be easily adapted to future projects.

The high panel covers the total height of the exterior wall plus the determined thickness of the total panel. Its advantage lays in that fewer number of pieces are handled compared to the CAP resulting in better performance.

Slab Panel

Tie

Wall Panels

Floor

Wall-slab Union height

Wall – Slab Union

Wall thickness

Tie

Wall Panels

Free Height= Wall panel height + Wall – Slab Union

Wall thickness

Wall thickness

High wall juncture

High Wall Panel

Standard Wall Panel of 2.10 to 2.40 meters

Wall – Slab Union

Wall thickness

Free Height= Wall panel height + Wall – Slab Union

CAP

Slab Panel

Floor

9


WALL SYSTEM Panels for Back End (Culatas) These determine the shape, height and angle of inclination of the wall. The panels for back ends are connected to wall panels with a staple pin in the lower edges and clips and stays on the lateral edges.

Wall Top Aluminum profile of 3/8� thickness that is used to close the wall.

> 12

It is assembled the same way as the panels (with clips and stays) or at times, if the configuration is not standard, pin staples can be used. For walls with a thickness greater than 12 cm, the wall top is re-enforced with angle profiles or a tubular profile.

When the design requires wall recesses or doorways, it is necessary to use the wall top with a mold. These are made with aluminum profiles 6061 and should be re-enforced and connected to the wall panels with clips and stays or when necessary pin staples.

10

< 12


WALL SYSTEM Construction in series has to be clearly defined on how to make the transition from one housing unit to another. FORSA delivers key panels and the necessary accessories to do continuous set-ups in whichever of two cases: flat foundations or in tiers.

Double Wall

Angle Stays Slab Panel Wall thickness

Wall Thickness

Expansion juncture (polystyrene) Double wall tie

Angle Stay Wall Panels

Wall panel height

Wall – Slab Union

Free Height= Wall panel height + wall slab juncture

Wall – Slab union height

When there are enlarged double walls, special ties are used that are fastened to the wall constructed the previous day, with angle stays.

Floor

11


WALL SYSTEM Enlarged Double Walls and Tiers Roof panel

The FORSA wall system permits the wall panels to be used for constructing housing units in tiers which can be between one house and another or within the same housing unit.

Wall thickness Connector height wall

Polystyrene or other material Wall panel height

Wall Thickness

Angle Stay Tie

Wall Panels

Floor

Retaining Stay

Free Height= Wall panel height + wall slab juncture

Wall border

Floor

The panels have slots in three perforations of the bushing to permit their use in tiers in multiples of 5 cm, except those tiers between one housing unit and another of 15, 45, 75 and 105 cm.

Retaining Stay Accessory used for connecting the panel to the lower part, when there are tiers up to 50 cm. For higher tiers they are to be used with a construction jack.

12


WALL SYSTEM $GMXVWPHQW 3URĂ€OH

Adjustment Filler It is used as an adjustment element or for general usage when the spaces are not multiples of 5 cm. In the event that the same work team is building different housing units, they can be included in changes of wall thickness.

In the event that it is necessary to make quick adjustments on the job, the adjustment profile can be used. This is an aluminum profile with an edge for placing a wood board of 1/2� thickness with which panels of various widths can be made up to a maximum of 30 cm. Variable

1 cm 2 cm

Max. 30 cm

15 cm 30 cm

30 cm

30 cm

5 cm 30 cm

30 cm

30 cm 15 cm

13