CONFERENCE PRESENTATION North American Passive House Conference 2018 Boston, MA
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
LOW ENERGY BUILDING DESIGNProcess and case studies MORPHOLOGY Process and case studies
Richard Pedranti, AIA
Richard Pedranti Architect September 21, 2018
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
TIMELINE OF BUILDING MORPHOLOGY
1300 1200
1700
1500 1400
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
1600
1900 1800
2018
TIMELINE OF BUILDING MORPHOLOGY
1300 1200
1700
1500 1400
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
1600
1900 1800
2018
TIMELINE OF BUILDING MORPHOLOGY
1300 1200
1700
1500 1400
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
1600
1900 1800
2018
TIMELINE OF BUILDING MORPHOLOGY
1300 1200
1700
1500 1400
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
1600
1900 1800
2018
TIMELINE OF BUILDING MORPHOLOGY
1300 1200
1700
1500 1400
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
1600
1900 1800
2018
CLIMATE AND FORM CLIMATE and FORM
Climate and Form diagram from chapter 1
Heating, Cooling, and Lighting as Form Givers in Architecture Norbert Lechner 2015 Heating, Colling, Lighting : sustainable design methods for architects COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
DESIGN METHODOLOGY
SITE AND FORM
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
DESIGN METHODOLOGY
SITE AND FORM
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
DESIGN METHODOLOGY
SITE AND FORM
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
DESIGN METHODOLOGY
SITE AND FORM
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
Case Study 1 Scranton Passive House OUR FIRST PASSIVE HOUSE
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
N
Site: Urban neighborhood COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
Mechanical core
N
Environmental separator Daylighting core
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
SOUTH
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE SVR 0.32 GLASS 14% SOUTH GLASS 47%
MORPHOLOGY ROOF R=91
5KW PV WALL R=61
SLAB R=76
ENVELOPE R VALUE = 36.2 GENERAL INFO SCRANTON, PA 2,153 SQFT CLIMATE ZONE 5/6 HERS 28 PV TO ZERO 5KW
MECHANICAL BALANCED VENTILATION HEAT / COOL HOT WATER WINDOWS
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
RENEWAIRE ERV MITSUBISHI ASHP GE HWHP INTUS EFORTE
PASSIVE HOUSE METRICS ANNUAL HEAT DEMAND HEAT LOAD PRIMARY ENERGY AIR TIGHTNESS TREATED FLOOR AREA
4.52 KBTU/(FT2YR) 2.75 KBTU/(FT2YR) 31.5 KBTU/(FT2YR) 0.47ACH@50PA 1,750 SQFT.
SCRANTON PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE This simple, traditional, PHIUS design offers a clear path to a solid sustainable home. GREEN BUILDER MAGAZINE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SCRANTON PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY
Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY Efficient geometry
Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY Efficient geometry Compact volume (Form)
Air tight volume
Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY High R value enclosure (TB free) Efficient geometry Compact volume (Form)
Air tight volume
Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY High R value enclosure (TB free) Efficient geometry Compact volume (Form)
Careful window placement and ratios
Air tight volume
Careful shading Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY High R value enclosure (TB free) Efficient geometry Compact volume (Form)
Air tight volume
Careful window placement and ratios
Mechanical core
Careful shading Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY High R value enclosure (TB free) Efficient geometry Compact volume (Form)
Air tight volume
Simple ventilation layout DHW Heating Careful window placement and ratios
Mechanical core
Careful shading Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY Renewables Efficient geometry Compact volume (Form)
Air tight volume
High R value enclosure (TB free) Simple ventilation layout DHW Heating Careful window placement and ratios
Mechanical core
Careful shading Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
OPTIMIZED BUILDING MORPHOLOGY High R value enclosure (TB free)
Renewables
Simple ventilation layout DHW Heating
Efficient geometry Compact volume (Form)
Careful window placement and ratios
Mechanical core
Air tight volume Daylighting core Optimized solar orientation
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
Careful shading
DESIGN PARAMETERS A Science / Quantitative Orientation Compact volume (Form) Efficient geometry (SVR) R value Glazing placement Glazing ratios Shading Thermal bridging Air tightness Ventilation Water management Vapor management System design Equipment efficiency Renewables COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
DESIGN PARAMETERS A Science / Quantitative Orientation
B Architecture / Qualitative Place
Compact volume (Form)
Landscape
Efficient geometry (SVR)
Aesthetics
R value Glazing placement Glazing ratios Shading
Order Technology Social patterns Culture
Thermal bridging
Structure
Air tightness
Materials
Ventilation
Experience
Water management
Comfort
Vapor management
Health
System design
Light
Equipment efficiency
Sound
Renewables
Space
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
LOW ENERGY BUILDING DESIGN MAP A Science / Quantitative Orientation Compact volume (Form) Efficient geometry (SVR) R value Glazing placement Glazing ratios Shading
B Architecture / Qualitative SITE
Place Landscape Aesthetics Order Technology Social patterns Culture
Thermal bridging
Structure
Air tightness
Materials
Ventilation
Experience
Water management
Comfort
Vapor management
Health
System design
Light
Equipment efficiency
Sound
Renewables
Space
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
LOW ENERGY BUILDING DESIGN MAP A Science / Quantitative Orientation Compact volume (Form)
B Architecture / Qualitative SITE
Efficient geometry (SVR)
Order
Glazing placement Shading
Landscape Aesthetics
R value Glazing ratios
Place
Technology
FORM
Social patterns Culture
Thermal bridging
Structure
Air tightness
Materials
Ventilation
Experience
Water management
Comfort
Vapor management
Health
System design
Light
Equipment efficiency
Sound
Renewables
Space
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
LOW ENERGY BUILDING DESIGN MAP A Science / Quantitative Orientation Compact volume (Form)
B Architecture / Qualitative SITE
Efficient geometry (SVR)
Order
Glazing placement Shading
Landscape Aesthetics
R value Glazing ratios
Place
Technology
FORM
Social patterns Culture
Thermal bridging
Structure
Air tightness
Materials
Ventilation
Experience
Water management
Comfort
Vapor management
Health
System design Equipment efficiency Renewables COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SPACE
Light Sound Space
LOW ENERGY BUILDING DESIGN MAP A Science / Quantitative Orientation Compact volume (Form)
B Architecture / Qualitative SITE
Efficient geometry (SVR)
Place Landscape Aesthetics
The art of optimizing BOTH Order Glazing placement Technology “sides” is where successfulSocial patterns Glazing ratios FORM Shading Culture Passive House design Thermal bridging Structure Air tightness separates itself from simply Materials Ventilation Experience achieving energy efficiency. Comfort Water management R value
Vapor management System design Equipment efficiency Renewables COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
Health
SPACE
Light Sound Space
Quantitative
1. 2. 3. 4. 5.
SOLAR ORIENTATION HIGH INSULATION HIGH PERFORMANCE WINDOWS AIR TIGHT CONSTRUCTION BALANCED VENTILATION
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
Experience
1. 2. 3. 4. 5.
COMFORT AIR QUALITY SOUND AND DAYLIGHT SIMPLICITY BEAUTY
Case Study 2 Soeder Passive House A HOME IN THE COUNTRY
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE
N
Site: Rural farm country with views COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE Mechanical core
Environmental separator
N Daylighting core
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE
SOUTH
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE SVR 0.32 GLASS 14% SOUTH GLASS 51%
MORPHOLOGY ROOF R=100
WALL R=60
FOUNDATION R=42 ENVELOPE R VALUE = 38.5 GENERAL INFO BECHTELSVILLE, PA 2,600 SQFT CLIMATE ZONE 5/6 HERS 30 PV TO ZERO 6KW
MECHANICAL BALANCED VENTILATION HEAT / COOL HOT WATER WINDOWS
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
ZEHNDER 350 MITSUBISHI ASHP GE HWHP INTUS EFORTE
PASSIVE HOUSE METRICS ANNUAL HEAT DEMAND HEAT LOAD PRIMARY ENERGY AIR TIGHTNESS TREATED FLOOR AREA
4.75 KBTU/(FT2YR) 2.84 KBTU/(FT2YR) 34.5 KBTU/(FT2YR) 0.22 ACH@50PA 2,440 SQFT.
SOEDER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE This is a great performing home… The design of the home was also very well executed, with plenty of room for the family and a sense of space in a small footprint. Chris McTaggart BER, HERS manager PHIUS+ QA manager
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
SOEDER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
FORM = ENERGY DIAGRAM OF PASSIVE HOUSE ENVELOPE CALCULATIONS
Diagram created by Alan Benoit and Richard Pedranti during CPHC training at Yestermorrow in 2012 COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SVR STUDY
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SVR STUDY
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
SVR STUDY
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
It’s a box
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
It’s not a box COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
Frank Lloyd Wright and the Destruction of the Box H. Allen Brooks March 1979 Journal of the Society of Architectural Historians COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
Case Study 3 Keffer Passive House BREAKING THE BOX
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
N
Site: In a forest on a lake COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
N
Site: In a forest on a lake COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE Mechanical core Box 2
Daylighting core Box 1
Environmental separator
N
Green box is Kitchen volume
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
SOUTH
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE SVR 0.34 GLASS 15% SOUTH GLASS 67%
MORPHOLOGY ROOF R=100
WALL R=62
SLAB R=76 ENVELOPE R VALUE = 38.5 GENERAL INFO HAWLEY, PA 2,900 SQFT CLIMATE ZONE 5 HERS 32 PV TO ZERO 7KW
MECHANICAL BALANCED VENTILATION HEAT / COOL HOT WATER WINDOWS
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
ZEHNDER 350 MITSUBISHI ASHP NYLES GEYSER INTUS EFORTE
PASSIVE HOUSE METRICS ANNUAL HEAT DEMAND HEAT LOAD PRIMARY ENERGY AIR TIGHTNESS TREATED FLOOR AREA
4.65 KBTU/(FT2YR) 2.93 KBTU/(FT2YR) 27.3 KBTU/(FT2YR) 0.29 ACH@50PA 2,304 SQFT.
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
KEFFER PASSIVE HOUSE “The passive house structure’s
large south-facing windows provide lots of natural light.” Lynn Keffer
COPYRIGHT 2017 RICHARD PEDRANTI ARCHITECT, PC
LESSONS LEARNED 1. SITE
SITE
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
LESSONS LEARNED 1. SITE
SITE 2. FORM
FORM
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
LESSONS LEARNED 1. SITE
SITE 2. FORM
FORM
3. SPACE
SPACE
COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
RICHARD PEDRANTI ARCHITECT www.richardpedranti.com
RESOURCES Heating, Cooling, Lighting Sustainable Design Methods for Architects Norbert Lechner Wiley 2015
Frank Lloyd Wright and the Destruction of the Box H. Allen Brooks Journal of the Society of Architectural Historians 1979
Design With Climate Biolclimatic approach to architectural regionalism Victor Olgyay Princeton University Press 1963
Transparency: Literal and Phenomenal Colin Rowe and Robert Slutzky Perspecta, Volume 8 1963 COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC
RICHARD PEDRANTI ARCHITECT www.richardpedranti.com
129 Sawkill Avenue Milford, PA 18337 Office (570) 296-0466 richard@richardpedranti.com COPYRIGHT 2018 RICHARD PEDRANTI ARCHITECT, PC