CATGENX0109RUGB
In the interests of product improvement Riello UPS reserves the right to change specifications without notice.
General Catalogue 01. 2009
Index Product Range
6-63
Plug Dialog iDialog / iDialog Plus Win Dialog Plus Net Dialog Dialog Vision Dialog Plus Dialog Plus Rack Dialog Dual Power Dialog 3 Multi Plus Multi Dialog Master Plus Master Plus HIP Master Plus Industrial Master Plus 400 Hz Master Dialog RM/RT Multi Switch Master Switch
Standby Power Systems
64-65 66-67 Sinux Inverters
Connectivity
68-76
Powershield3 PowerNetGuard Environmental Sensors Netman 101/102 Plus Multicom 301/302 Multicom 351/352 Multicom 362 Multicom 372 Multicom 382 Multi I/O USB Converter Multifunction I/O Multicom 401 Kit AS400 / i-Series Multi Panel Compatibility Table
By-pass Accessories
77
Services and Consultancy
78
Riello UPS & Riello Elettronica Established in 1986, Riello Elettronica is the parent company of a group of businesses operating within the Energy, and Automation and Security sectors. The company started manufacturing switching power supplies for information technology applications, before moving into the manufacture of Uninterruptible Power Supplies (UPS). In 1995 Riello Elettronica became a holding company with operations within civil and industrial electronics, plant engineering and information technology sectors, security and intelligent home systems, and its established UPS manufacturing business. Also part of this strategic development was the restructuring of its energy-related activities under a new organisation – Riello UPS.
PIERANTONIO RIELLO
Frost & Sullivan awards
official sponsor Ducati C o r s e
2
The main activities of RIELLO UPS are the research & development, design, manufacture, sale and service of Uninterruptible Power Supplies. These are used throughout the world to provide a guaranteed continuous supply of electrical energy to information technology systems, used within data centres and IT network operations within finance, transportation, industrial manufacturing, health and other critical sectors. Riello UPS has become a market leader in Europe and one of the World’s top five UPS manufacturers thanks to its focus on customer service, investments and experience. The Riello UPS product range includes solutions for powering the smallest desktop PCs or the latest super computers used within the most advanced data centre operations. Riello UPS can be found within banks, hospitals, airports and almost wherever a continuous electrical supply is critical. The UPS range includes single-phase and three-phase systems from 400VA up to 6.4MVA. POWER QUALITY: CONTINUOUS ENERGY. Riello UPS is committed to the supply of power solutions providing the highest level of efficiency, resilience and power quality on a global basis and for any application requiring continuous energy. Power Quality can be defined using two parameters: • Continuity - the availability of the power supply and its resilience • Waveform - the purity of the waveform in terms of its voltage and current characteristics The Riello UPS product range is extensive, ensuring the availability of a power solution for any critical application requiring a single UPS or turn-key solution combining UPS, Static Transfer Switches, Inverters and other power products.
BUSINESS CONTINUITY AND CONNECTIVITY RIELLO UPS products represent ‘state-of-the-art’ developments within the energy management sector. There are currently 15 UPS product lines offering various operating topologies and configurations. Their principle application is within ‘Business Continuity’. Here Riello UPS guarantee the power quality supplied to critical applications, to allow them to function during partial or complete mains power supply failures. This quality concept is central to the Riello UPS corporate culture and every aspect (including products, personnel and services) revolves around this. Whilst product quality is a prerequisite, it is the human element that can also differentiate a company and deliver true value added. All Riello UPS personnel are actively encouraged, wherever they are within the organisation, to contribute towards improvements, whether they relate to products, systems or services. Teamwork is an essential aspect of this approach to quality and the certifications received from external bodies and customer endorsements are proof that Riello UPS is achieving its quality objectives. INNOVATION. THE PRIMARY OBJECTIVE. Riello UPS operates two research centres in Italy: one in Legnago (near Verona) for transformerless UPS up to 120kVA and the other in Cormano (Milan) for transformer-based systems up to 800KVA and custom-design products. A separate design team also operates from the Milan facility and is dedicated to the research and development of inverter photovoltaic applications. The research centres are separated into three distinct areas of activity within the new product development process: • Projects: concerned with concept design • Experimental: for concept testing, analysis and evaluation within laboratory conditions • Testing: prototype validation Each phase is part of a continuous innovation process that is designed to deliver world beating power solutions to solve today’s energy problems.
EUROPEAN PRODUCTS - AN INTERNATIONAL COMPANY In a world where many companies are choosing to locate manufacturing based on labour costs, often sacrificing product and service quality, Riello UPS continues to invest in a European production system. This creates two positive benefits: the Riello UPS product range is highly reliable, benefiting from an approach to research & development, manufacturing, distribution and service that it totally integrated. Secondly, the process strengthens a culture of ‘continuous improvement”, providing timely feedback, even during manufacture and assembly. The end result is a superior product range that enhances the reputation that Riello UPS enjoys for efficiency, resilience and quality.
CEMEP UPS Efficiency leaflet
3
ECO Energy Levels
Riello UPS has a company-wide initiative to become the most environmentally friendly power protection company in Europe. As a company, Riello UPS is a major contributor to the European Commission – Code of Conduct on Energy Efficiency and Quality of AC Uninterruptible Power Supplies - and the first European manufacturer to rate its products for ECO Energy Level effciency. The European Commission Code of Conduct is a document signed by the major UPS manufacturers in Europe which outlines the efficiency levels to reach for specific size bands from 10-800kVA, from 25% to 100% loading. For a 200kVA UPS at full load the benchmark is 93% in full on-line mode. In addition to making its products achieve the highest possible operating efficiencies, Riello UPS has also focused its research and development efforts on other aspects that impact the environment. • Adaptive battery management to lengthen the period between battery replacement and disposal programmes and reduce the wear on other consumables such as fans and capacitors. • Low Total Harmonic Distortion on the input side (THDi) of (3%) to reduce the impact on upstream equipment and a high input power factor (0.99). • Adaptive “Smart Mode” operation in which the UPS selects a mode of operation that matches the electrical characteristics of the mains power supply to the power protection performance required by the load. ECO ENERGY LEVELS Riello UPS powers some of the most critical data centres in use today. Within such environments, energy management is critical. Running costs must be minimised without compromising resilience and the capabilities to withstand a mains power supply interruption and disruption of service. Efficiency levels must be at the highest possible levels to reduce the stress on critical power supplies and minimise the effect on local ambients. 4
The ECO Energy Level ratings used within this guide identify how Riello UPS products comply with the European Commission Code of Conduct. There are six levels, with level 6 being the highest that can be achieved by a UPS in full on-line mode as defined by VFI-SS-111. ‘Smart Mode’ is an intelligent economy mode at which even higher levels of efficiency can be achieved. The Riello UPS ECO Energy Levels rating system demonstrates the Riello commitment to the environment and promotes an open-way for users to identify potential cost-savings from reduced operational energy usage, lower heat outputs and carbon-footprints. Riello UPS is the first UPS manufacture to differentiate its products using the ECO Energy Levels guide. The rating system has been applied from 3kVA (below the 10kVA threshold limit applied by the European Commission) because Riello UPS is committed to the environmental impact of its entire product range.
1
2
3
4
5
6
Energy Level
Comparison between UPS efficiency with CoC
“Smart Mode” availability
ECO 6
Higher
Yes
ECO 5
Higher
-
ECO 4
Matches
Yes
ECO 3
Matches
-
ECO 2
Lower
Yes
ECO 1
Lower
-
Riello UPS and Environment
SUSTAINABLE ENERGY FOR OUR FUTURE. With a concern for the environment, Riello UPS has taken an active role in developing a culture of sustainable development and reduced energy consumption. It has established a number of environmentally friendly projects and made substantial R&D investments into new technologies. These are targeted at the generation of ‘clean energy’ products and the development of even more efficient UPS in the future. This is a social commitment, which will benefit the present and have a positive impact on the future; the Riello UPS Environmental Management System was recently accredited to ISO14001 as testament to the Riello commitment to the environment. HELIOS INVERTERS - HARNESSING SOLAR ENERGY Riello UPS is also focused on renewable energies and in particular solar power and the use of its Helios range of inverters. Solar power is readily available and its use can help to reduce dependence on oil and other carbon fuels. As part of this programme, Riello UPS has invested in the design of an innovative Inverter range for grid-connected photovoltaic plants. Its Helios Power Inverters offer high reliability and performance features that allow a substantial recovery of the capital initial investment within a short timeframe. The systems are transformerless offering reduced costs and higher operating efficiencies.
WER HELIOS PO
Ask for Helios Power solar inverter catalogue.
5
Personal computerS
Plug Dialog 350-550 VA
Plug Dialog 350-550 VA
single-phase
The PLUG DIALOG range is the ideal solution for small office and home systems (SOHO) requiring over voltage and mains failure protection. The compactness, versatility (a push-button switch with LED-based mimic panel and user-replaceable batteries) and functionality of the PLUG DIALOG allow it to easily fit into any small office and home environment. When the mains fails, connected loads are powered with a pseudo sinewave supply from the inverter. For additional security users can download a version of the PowerShield3 UPS monitoring and control software. LOAD CONFIGURATOR Load type
Personal computer
250
LCD Monitor
70
15” Monitor
150
Scanner, printer
200
Modem, TV, DVD reader, PlayStation, Hi-Fi, Phone, Fax
50
Laser printer**
200
*Average estimated value. **Use the Plug DIALOG filtered power output.
6
Power (VA)*
CHARACTERISTICS • Maximum compactness • 3 sockets with mains fail protection • 1 socket with filtering for powering loads such as laser printers • Integrated protection for telephone line/modem • Cold Start capability: the UPS can power up without a mains supply present • User replaceable batteries • USB interface • Can be placed on a desktop, floor or be wall-mounted • Input supply and telephone cable included • Short-circuit protection • Auto restart (on mains return, after batteries have discharged) • GS/TÜV marks • Available with French (2P+T), UK or Schuko sockets ADVANCED COMMUNICATION • PowerShield3 monitoring and shut-down software for Windows 2008, Vista, 2003, XP; Linux, Mac OS X and Sun Solaris • Plug and Play function 2 YEAR WARRANTY
MODELS POWER
PDG 400
PDG 600
350VA/225W
550VA/335W
INPUT Rated voltage
230 Vac
Voltage range
188-262 Vac
Frequency
50/60 Hz
OUTPUT Voltage on mains operation
230 Vac
Frequency on battery operation
50 or 60 Hz
Waveform from battery/inverter
Pseudo sinewave
BATTERIES Type
VRLA AGM Maintenance-free lead-acid
Recharge time
6-8 h
ENVIRONMENTAL 3
3.1
Dimensions (HxWxD) (mm)
88 x 120 x 320
Tel/Modem protection
RJ11/45 connectors
Communication Compliance
USB interface EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3 EN 62040-2 and Directive 2004/108 EC
Marks
CE; GS/TÜV
Operating temperature
0°C ÷ +40°C
Colour
Graphite grey
Altitude and relative humidity Accessories provided
Sockets
Plug Dialog 350-550 VA
Weight (kg)
6000 meters max. elevation, < 95% non condensing 1 input supply cable, telephone cable
PDG 400 - PDG 600
Sockets with UPS protection (no break in power if mains fails) Filtered socket: overvoltage protection only
USB communication port Mains input Phone/modem protection
TECHNICAL DETAILS
On/off button leds
AVAILABLE SOCKETS
French socket
schuko socket
British socket
7
Personal computerS
Small computerS Network
iDialog / iDialog Plus 400-800 VA / 400-1600 VA iDialog / iDialog Plus 400-800 VA / 400-1600 VA
single-phase
The iDialog UPS has been designed to protect PCs and critical peripherals in home and small office environments. iDialog is easy to install and provides powerful, economic protection for: • IT equipment including PCs, Media Centers, PoE, VoIP and other such peripherals • TVs, Home Cinemas, Satellite and Digital Terrestrial receivers, DVD readers and writers • Modems and xDSL routers • Small household appliances
Characteristics • Maximum power protection with PowerShield3 UPS monitoring and shutdown software available for free download from our website www.riello-ups.com • Suitable for installation on PCs running Windows 2008, Vista, 2003, XP; Linux, Mac OSX and the Sun Solaris operating system. • Compact dimensions and ergonomic design: iDialog can be placed on a desk top or other convenient location, with easy to access connections and informative front panel. • Front panel LCD display (Plus version only) providing status, load and battery information and LEDs (standard version). • Silent running: iDialog can be used to protect other senstiive electronic devices including Home Cinemas, CD Writers, DVD players, Satellite and Digital Terrestrial receivers. 2 YEAR WARRANTY
8
MODELS POWER
ID 40
ID 60
ID 80
IDP 40
IDP 60
IDP 80
IDP 110
IDP 160
400VA/240W
600VA/360W
800VA/480W
400VA/240W
600VA/360W
800VA/480W
1100VA/660W
1600VA/960W
6.6
7
INPUT Rated voltage
220-240 Vac
Voltage range
230 Vac (+20/-25%)
Frequency
50/60 Hz auto sensing
OUTPUT Voltage on mains operation
230 Vac (+/- 15%)
Voltage on battery operation
230 Vac (+/- 10%)
Frequency on battery operation
50 or 60 Hz (+/- 1%)
BATTERIES Type
VRLA AGM Maintenance-free lead-acid
Recharge time
6-8 h
Weight (kg)
3
3.2
Dimensions (HxWxD) (mm)
192 x 90 x 232
Tel/Modem protection -
Output sockets
4 IEC
USB 4 IEC or 3 Schuko/Italian or 3 french
Altitude and relative humidity Accessories provided
6 IEC or 4 Schuko/Italian or 4 french
EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3 EN 62040-2 and Directive 2004/108 EC
Operating temperature Colour
275 x 97x 315
RJ11/45 connectors
Communication
Compliance
3.4
iDialog / iDialog Plus 400-800 VA / 400-1600 VA
ENVIRONMENTAL
0°C ÷ +40°C Dark grey RAL 7016 6000 meters max. elevation, < 95% non condensing 2 output supply cables (IEC version), 1 USB cable (plus version), user guide
ID 40 ID 60 ID 80
IDP 40 IDP 60 IDP 80
IDP 110 IDP 160
Sockets with UPS protection (no break in power if mains fails) Phone/modem protection
USB communication port Filtered socketS: overvoltage protection only Mains input
TECHNICAL DETAILS AVAILABLE SOCKETS IDP F
IDP S
IDP
French socket
schuko socket
IEC socket
9
Personal computerS
Small computerS Network
Win Dialog Plus 400-800 VA
Win Dialog Plus 400-800 VA
single-phase
The WIN DIALOG PLUS series includes the 400-600-800VA models and uses digital technology. The load is powered from the mains through an AVR to stabilise brownout, sag and surge voltages, and EMI filters to suppress spikes and transients. When the mains fails, the load is powered by the inverter with a pseudo sinewave to provide sufficient runtime for computer system shutdown using the PowerShield3 software supplied as standard.
ADVANCED COMMUNICATION • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, and the Sun Solaris operating system. • Advanced communication (standard USB interface) 2 YEAR WARRANTY
CHARACTERISTICS • Mains power supply stabilisation and filtering (technology with AVR and filters for atmospheric disturbance suppression) • Cold Start capability: the UPS can power up without a mains supply present • High reliability with built-in battery test feature • Supplied with 2 output cables
10
MODELS POWER
WP 40U
WP 60U
WP 80U
400VA/240W
600VA/360W
800VA/480W
INPUT Rated voltage
220-240 Vac
Voltage range
230 Vac (+20/-26%)
Frequency
50/60 Hz auto sensing
OUTPUT Voltage on mains operation
230 Vac (-8%, +10%)
Voltage on battery operation
230 Vac (+/- 5%)
Frequency on battery operation
50 or 60 Hz (+/- 0.5%)
Waveform from battery/inverter
Pseudo sinewave
BATTERIES Type
VRLA AGM Maintenance-free lead-acid
Recharge time
6-8 h
ENVIRONMENTAL Weight (kg)
5.8 152 x 110 x 325
Communication
Win Dialog Plus 400-800 VA
Dimensions (HxWxD) (mm)
6.2
USB EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3 EN 62040-2 and Directive 2004/108 EC
Compliance Operating temperature
0°C ÷ +40°C
Colour
Dark grey RAL 7016
Altitude and relative humidity
6000 meters max. elevation, < 95% non condensing
Accessories provided
2 output supply cables, comunication software; user guide
WP 40U WP 60U WP 80U
USB
Mains input Output sockets
TECHNICAL DETAILS
11
Personal computerS
Small computerS Network
Net Dialog 800-2000 VA
Net Dialog 800-2000 VA
single-phase
The NET DIALOG series includes the 800-1000-1500-2000 VA models and uses digital technology. The load is powered from the mains through an AVR to stabilise brownout, sag and surge voltages, and EMI filters to suppress spikes and transients. When the mains fails, the load is powered by the inverter with a pseudo sinewave to provide sufficient runtime for computer system shutdown using the PowerShield3 software supplied as standard. The UPS also incorporates a filtered socket for PC network and telephone line cable protection. For advanced communication and top flight performance, NET DIALOG is the ideal solution for small network users requiring total control of their power system.
• Auto restart at power-up • Integrated protection for PC networks and telephone line/modem connections RJ11/45 • High reliability with built-in automatic battery test feature
CHARACTERISTICS • Mains power supply stabilisation and filtering (technology with AVR and filters for atmospheric disturbance suppression) • Cold Start capability: the UPS can power up without a mains supply present
2 YEAR WARRANTY
12
ADVANCED COMMUNICATION • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. • The UPS is supplied with a communications cable for Plug and Play PC connection
MODELS POWER
ND 80
ND 100
ND 150
ND 200
800VA/480W
1000VA/600W
1500VA/900W
2000VA/1200W
INPUT Rated voltage
220-230-240 Vac
Voltage range
230 Vac (±25%)
Frequency
50/60 Hz auto sensing
OUTPUT Voltage on mains operation
230 Vac (-8%, +10%)
Voltage on battery operation
230 Vac (+/- 5%)
Frequency on battery operation
50 or 60 Hz (+/- 0.5%)
Transfer time
2 ms
Waveform from battery/inverter
Pseudo sinewave
BATTERIES Type
VRLA AGM Maintenance-free lead-acid
Recharge time
4-6 h
ENVIRONMENTAL
Dimensions (HxWxD) (mm) Protection
14
14.5
15
180 x 140 x 375
RJ11/45 connectors
Communication
RS232 port EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3 EN 62040-2 and Directive 2004/108 EC
Surge capability
IEC 801-5
Operating temperature
0°C ÷ +40°C
Storage temperature Relative humidity
214 x 140 x 410
Battery low - overcurrent - short-circuit
Tel/Modem protection
Compliance
20
Net Dialog 800-2000 VA
Weight (kg)
-15°C ÷ +45°C < 95% non condensing
Noise
< 40 dBA at 1 m
Colour
Dark grey RAL 7016
ND 80 ND 100 ND 150
ND 200
SERIAL INTERFACE PORT TELEPHONE LINE MODEM PROTECTION
OUTPUT SOCKETS MAINS INPUT
TECHNICAL DETAILS
13
Small computerS Network
Local Area Networks (LAN)
Workstations
ServerS
EPOS (Electronic Point of Sales)
System
Dialog Vision 500-3000 VA
Dialog Vision 500-3000 VA
single-phase
The DIALOG VISION series includes the DVT (Tower version), DVR (Rack version) and DVD (Dual Rack/Tower version) with models from 500VA to 3000VA and uses sinewave digital technology. The DIALOG VISION range, with its advanced communications and connectivity options, is the ideal solution for the most demanding of customers looking for superior protection and versatility.
1. Release the mimic panel by applying pressure to the catch
2. Rotate the mimic panel and fasten it back on again
DIALOG VISION is the best protection for network devices, rackmounted servers, conventional rack-mounted or tower servers, network storage systems.
3. Turn the UPS 90째
4. Slide the UPS into the rack cabinet
90째
90째
14
HIGH AVAILABILITY One PowerShare socket for load-shedding of the least critical loads to maximise back up time for the most critical servers. Hot swappable battery (front access) for simple and risk-free UPS maintenance. Additional Battery Boxes (with chargers) are available for the DVD 220 and 300 for long back up time applications. Battery Test facility to detect deteriorating battery performance and failure. Deep discharge protection: in the case of low load long discharge periods, the end-of-discharge voltage threshold is increased as recommended by battery manufacturers, in order to avoid damaging the battery VERSATILITY Dialog Vision Dual (DVD150, 220 and 300) can be placed directly onto the floor or mounted in 19’’ rackmount cabinets. The front panel digital display can be easily pulled out and rotated to suit the installation format. DVD and DVR versions include an Emergency Power Off (EPO) input contact. Cold Start function to allow a Dialog Vision to power up with no mains power supply present. ADVANCED COMMUNICATION • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. • USB or RS232 serial port (selectable) • Slot-in SNMP network adapter card • LCD Display
DVR 50/80/110
POWERSHARE SOCKET
OUTPUT SOCKETS IEC
MAINS INPUT IEC
DVD 150
SERIAL INTERFACE PORT RS232
USB PORT
EPO
THERMAL FUSES
OUTPUT SOCKETS IEC
TELEPHONE/IT NETWORK PROTECTION
DVD 220/300
BATTERY EXPANSION CONNECTOR
OUTPUT SOCKETS IEC 16A
DVT 50/80/110
Dialog Vision 500-3000 VA
VERY HIGH PROTECTION An Automatic Voltage Regulator (AVR) provides stabilisation from brownouts, sag and surge voltages. EMI filters then provide further protection from spikes and transients. When the mains power supply fails, the load is powered by the inverter and receives a true sinewave supply for maximum power continuity and reliability. The UPS also incorporates protection for PC and network, telephone line/ modem connections (RJ45-RJ11).
DVT 150/200 USB PORT
SERIAL INTERFACE PORT RS232 TELEPHONE/ IT NETWORK PROTECTION MAINS INPUT IEC
SLOT FOR SNMP NETWORK ADAPTER CARD
OUTPUT SOCKETS IEC POWERSHARE SOCKET
TECHNICAL DETAILS
2 YEAR WARRANTY
15
TOWER VERSION MODELS
DVT 50
DVT 80
DVT 110
DVT 150
DVT 200
500VA/350W
800VA/540W
1100VA/740W
1500VA/1050W
2000VA/1350W
235 x 110 x 383
235 x 110 x 383
235 x 110 x 383
235 x 160 x 425
235 x 160 x 425
7.2
10.6
11
18
18.4
IEC mains input plug
1 (10A)
1 (10A)
1 (10A)
1 (10A)
1 (10A)
IEC output sockets
4 (10A)
4 (10A)
4 (10A)
4 (10A)
4 (10A)
POWER Dimensions (HxWxD) (mm) Weight (kg)
RACK 1U and TOWER/RACK (Dual) 2U MODELS
DVR 50
DVR 80
DVR 110
DVD 150
DVD 220
DVD 300
500VA/350W
800VA/540W
1100VA/740W
1500VA/1050W
2200VA/1540W
3000VA/2100W
1U x 19” x 460
1U x 19” x 460
1U x 19” x 460
T 438 x 88 x 582 R 2U x 19” x 582
T 438 x 88 x 582 R 2U x 19” x 582
T 438 x 88 x 582 R 2U x 19” x 582
12
13.5
15.6
28.7
31
32.8
IEC mains input plug
1 (10A)
1 (10A)
1 (10A)
1 (10A)
1 (16A)
1 (16A)
IEC output sockets
4 (10A)
4 (10A)
4 (10A)
8 (10A)
8 (10A) - 1 (16A)
8 (10A) - 1 (16A)
POWER Dimensions (HxWxD) (mm) Weight (kg)
Rated voltage
230 Vac (selectable 200, 208, 220, 240 V)
Voltage range
160 V - 294 V
Frequency Frequency range
50/60 Hz auto sensing ±5%
OUTPUT Rated voltage
230 Vac (selectable 200, 208, 220, 240 V)
Frequency
50 or 60 Hz auto sensing
Waveform
True sinewave
BATTERIES Type Recharge time
VRLA AGM Maintenance-free lead-acid 4-6 h
ENVIRONMENTAL Protection Communication
Overload - short-circuit - overvoltage - undervoltage - temperature - low battery USB / RS232 / slot for interface communication
Compliance
EN 62040-1-1 and Directive 2006/95/EC EN 62040-2 and Directive 2004/108 EC
Performance
IEC / EN62040-3
Operating temperature Storage temperature Relative humidity
0°C ÷ +40°C -15°C ÷ +45°C < 95% non condensing
Noise
< 50 dBA
Colour
Dark grey RAL 7016
BATT. BOX MODELS DVD MODEL
BB 96-A5 DVD 220 - DVD 300
Dimensions (mm) hxwxd
88
Dialog Vision 500-3000 VA
INPUT
43
8
16
2
58
17
Dialog Vision 500-3000 VA
Small computerS Network
Local Area Networks (LAN)
Workstations
ServerS
EPOS (Electronic Point of Sales)
System
Dialog Plus 700-3000 VA
Dialog Plus 700-3000 VA
single-phase
The DIALOG PLUS series includes the 700-1000-1500-2000-3000VA models and uses double conversion technology (VFI). The load is powered continuously by the inverter with an EMI filter, stabilised and regulated sinewave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges, even on bypass. The UPS can power the load for long periods (using battery extension packs) or provide sufficient runtime to allow shut-down of the protected systems using the PowerShield3 software, supplied as standard, for Windows 95, 98, NT 4.0, Me, 2000, 2003, XP, Vista, Mac OS 9.x, X, Linux operating systems. For outstanding power protection and communication DIALOG PLUS is the best solution for sensitive and “mission-critical” applications. DIALOG PLUS-ER models are supplied with a larger internal charger and with their matching external battery extension packs can achieve long back up times. CHARACTERISTICS • Reliable, filtered, stabilised and regulated sinewave output (double conversion technology VFI in conformance with IEC 62040-3 specifications) with filters for atmospheric disturbance suppression • High level immunity to surges (up to 150%) • Auto restart on mains return (programmable) • Start-up without mains (Cold Start)
18
• Power factor correction with sinusoidal input to ensure a low impact on the mains supply (UPS input power factor, close to 1) • Wide input voltage window (110-300Vac) to reduce battery usage • Integrated protection for PC networks and telephone line/modem connections RJ45-RJ11 • Option to extend the back up time to several hours • Software-programmable operating parameters • Timer for scheduled shut-down and power up (software programmable) • Highly reliable batteries with automatic and manual test feature • Highly reliable system with full microprocessor control • Breaker based input protection. ADVANCED COMMUNICATION • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. • Free UPS tools configuration software • RS232 serial port • Slot-in SNMP network adapter card. 2 YEAR WARRANTY
MODELS POWER
DLP 70
DLP 100
700VA/490W
DLP 100 ER
1000VA/700W
DLP 150
DLP 200
1500VA/1050W
DLP 200 ER
2000VA/1400W
DLP 300
DLP 300 ER
3000VA/2100W
INPUT Rated voltage Minimum voltage range
220-230-240 Vac 110V up to 60% of load / 120V from 60% to 70% of load / 140V from 70% to 80% of load / 160V from 80% to 100% of load
Maximum voltage
300 Vac
Rated frequency
50/60 Hz auto sensing
Power factor
> 0.97
Input current
Sinewave
BY PASS Voltage range
180 - 264 Vac
Frequency range
Selected frequency ±5Hz
OUTPUT Rated voltage
Selectable 220, 230 or 240 Vac ±1.5%
Voltage distortion
< 2%
Frequency
50 or 60 Hz auto sensing
Waveform
Sinewave
Crest factor
3: 1 110% 30’; 130% 30”; 150% 10”
Dialog Plus 700-3000 VA
Overloads BATTERIES Type Recharge time
VRLA AGM Maintenance-free lead-acid 2-4 h
-
2-4 h
4h
-
4h
-
19
MODELS
DLP 70
POWER
DLP 100
700VA/490W
DLP 100 ER
1000VA/700W
DLP 150
DLP 200
1500VA/1050W
DLP 200 ER
DLP 300
2000VA/1400W
DLP 300 ER
3000VA/2100W
ENVIRONMENTAL Weight (kg)
12
14
Dimensions (HxWxD) (mm)
8
19
231 x 158 x 400
Protection
34
231 x 158 x 500
35
15
340 x 192 x 460
Overload - short-circuit - overvoltage - undervoltage - temperature - low battery
Communication
RS232 + communication interface slot
Compliance
EN 62040-1 EMC EN 62040-2 Directive 2006/95/EC - 2004/108 EC; EN 62040-3
Operating temperature
0°C ÷ +40°C
Relative humidity
< 95% non condensing
Surge capability
3KA 8/20 µs
Colour
Dark grey RAL 7016
Noise
< 40 dBA at 1 m
Extended runtime solutions
-
yes
Isolation transf. box (HxWxD) (mm)
Dialog Plus 700-3000 VA
14
231 x 158 x 434
340 x 158 x 460
DLP 200 DLP 200 ER
DLP 300 DLP 300 ER
DLP 100 DLP 100 ER DLP 150
DLP 70
Slot for SNMP network adapter card
Serial interface
External battery pack socket
Output sockets
Thermal fuses Telephone/IT network protection INPUT socket
TECHNICAL DETAILS
BATTERY BOX MODELS DLP MODEL
BB 36-07 BB 36-12
BB 48-07 BB 48-12
BB 36-24
BB 48-24
BB 96-07 BB 96-12
BB 96-38
DLP 100
DLP 150
DLP 100/ER
DLP 150
DLP 200-300/ER
DLP 200-300/ER
231
340
630
Dimensions (mm) hxwxd
20
45
5
65
5
48
5
158
158
215
21
Dialog Plus 700-3000 VA
Local Area Networks (LAN)
ServerS
Data Centers
Cash Registers
Telecommunication devices
Industrial PLCs
Emergency Devices (lights/Alarms)
Dialog Plus Rack 700-3000 VA
Dialog Plus Rack 700-3000 VA
single-phase
For outstanding power protection and communication DIALOG PLUS RACK is the best solution for sensitive and “mission-critical” applications. The DIALOG PLUS RACK series comprises the 700-10001500-2200-3000VA models and uses double conversion technology (VFI). The load is powered continuously by the inverter with an EMI filtered, stabilised and regulated sinewave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges, even on bypass. The UPS can power the load for long periods (using battery extension packs) or provide sufficient runtime to allow shut-down of the protected computer systems using the PowerShield3 software, supplied as standard. DIALOG PLUS RACK -ER models are supplied with a larger internal charger and with their matching external battery extension packs can achieve long back up times. CHARACTERISTICS • Reliable, stabilised, filtered voltage double on-line conversion technology (VFI according to EN62040-3 specifications) with filters for the suppression of atmospheric disturbances • High overload capability (up to 150%) • Auto restart when mains power returns (programmable) • Power factor correction with sinusoidal input to ensure a low impact on the mains supply (UPS input power factor, close to 1)
22
• Wide input voltage range (110-300Vac) to reduce battery usage • Integrated protection for PC networks and telephone line/modem connections RJ45-RJ11 • Option to extend the back up time to several hours • Programming of operating functions via software • Timer for scheduled shut-down (software programmable) • High level reliability of the batteries (automatic and manual test) • High level reliability of the UPS (full microprocessor control) • Breaker based input protection. ADVANCED COMMUNICATION • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. • The UPS is supplied with a communication cable for Plug and Play PC connection • UPS tools configuration software • Emergency Power Off (EPO) contact • RS232 serial port • Slot-in SNMP network adapter card. 2 YEAR WARRANTY
MODELS
DLPR 70
POWER
DLPR 100
700VA /490W
DLPR 100 ER
1000VA/700W
DLPR 150
DLPR 220
1500VA /1050W
DLPR 220 ER
DLPR 300
2000VA /1400W
DLPR 300 ER
3000VA /2100W
INPUT Rated voltage
220-230-240 Vac
Minimum input range
110V up to 60% of load /120V from 60% to 70% of load /140V from 70 to 80% of load /160V from 80% to 100% of load
Maximum input range
300 V
Rated frequency
50/60 Hz ±5Hz
Rated current (A)
2.5
3.5
5.2
6.8
10
Power factor
13.8
14.4
16
> 0.97
BY PASS Voltage tolerance
static ± 1.5%
Frequency tolerance
±5Hz
BATTERIES Type
VRLA AGM Maintenance-free lead-acid
Recharge time
4h
OUTPUT 220 or 230 or 240 Vac selectable ± 1,5%
Waveform
Dialog Plus Rack 700-3000 VA
Rated voltage
Sinewave
Voltage distortion
< 2%
Frequency
50 or 60 Hz selectable
Frequency tolerance
± 0.5 %
Crest factor (Ipeak/Irms)
3: 1 (up to 100% of load)
Overloads
110% 30’; 130% 30”; 150% 10”
Output sockets
4 IEC 320 10A
4 IEC 320 10A + 1 IEC 320 16A
ENVIRONMENTAL Weight (kg)
13
Dimensions (HxWxD) (mm)
16
9
2U x 19” x 390
21
38
13
39
14
2U x 19” x 480
3U x19”x 560
2U x19”x 480
3U x19”x 560
2U x19”x 480
AC/AC Efficiency
90%
Communication
RS232 + communication interface slot
Operating temperature
0°C ÷ +40°C, ideal for battery 15°C ÷ +25°C
Relative humidity
< 95% non condensing
Protection
Overload - short-circuit - overvoltage - undervoltage - temperature - low battery
Compliance
EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108/EC; EN 62040-3
Surge capability
3KA 8/20 µs
Colour
Dark grey RAL 5004
Noise
< 40 dBA at 1 m Product characteristics can be customised to meet client specifications.
DLPR 70/100/100 ER/150
IEC output socket
Battery extension pack socket
OPTIONS Extended runtime solutions, except for the DLPR 70 model IEC mains input socket
DLPR 220/300
Input thermal protection
Serial interface port
IEC mains input socket
DLPR 220 ER/300 ER
Multipass (mm/kg): 2U x 438 x 360 - rack version weight 6.8 kg
B.B. MODELS
BBR 36-07 / 36-14
BBR 48-07 48-14
BBR 96-07
DLPR MODELS
DLPR 100/ER
DLPR 150
DLPR 220-300/ER
Dimensions (mm) hxwxd
TECHNICAL DETAILS
2U
2U 19’ ’
0
39
19’ ’
0
48
2U = 88 mm; 19” = 438 mm
23
Local Area Networks (LAN)
ServerS
Data Centers
Cash Registers
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Dialog Dual 3.3-10 kVA
single/single-phase and three/single-phase
Dialog Dual 3.3-10 kVA
6
DIALOG DUAL is the best solution for protecting medium sized networking applications which require the highest possible levels of reliability. The UPS is designed to support a wide range of applications from IT to security. DIALOG DUAL is unique in that the UPS can be placed directly onto the floor or mounted in 19” rackmount cabinets. The range is available in 3.3-4-5-6-8-10 KVA models. The UPS is primarily an on-line double-conversion (VFI) technology system with
1. Release the mimic panel by applying pressure to the catches
2. Rotate the mimic panel and fasten it back on again
further selectable operating modes that can configure the UPS to protect applications including emergency lighting, security and medical systems. Each UPS features advanced communications and diagnostics including a digital front panel display that can be turned to suit the installation format, RS232 and USB interfaces, and an internal adaptor slot for SNMP and other interface card options from RIELLO UPS. PowerShield3 is supplied as standard.
3. Turn the UPS 90°
4. Slide the UPS into the rack cabinet
90°
90°
24
• Unlimited extendable back-up time using modular design Battery Extension Packs • Increased ride through (without batteries) on mains breaks up to 40ms and for fluctuations ranging from 84 to 276Vac
SELECTABLE OPERATING MODES • On line Mode (VFI). • Economy Mode: increases efficiency (up to 98%), and uses Line Interactive technology to power low priority loads from the mains supply. • Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply. • Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode). • Frequency converter Mode (50 or 60 Hz).
OTHER CHARACTERISTICS • Output voltage selection: 220-230-240Vac • Auto restart when mains power returns - programmed using the UPS Tools Software supplied • Bypass on: when the UPS is switched off, it automatically goes into bypass mode to charge the batteries • Automatic power down due to minimum load • End of battery discharge pre-alarm • Delayed start up • Completely digitally controlled • Automatic bypass with no break in power supply • Use of IMS (Insulated Metallic Substrates) modules • Status, measurements, and alarms available on the standard backlit display • UPS can be updated digitally (flash upgradeable) • Input protected by resettable thermally activated switch • Back-feed protection: to avoid current being fed back into the mains should a fault occur • Manual switch over to bypass
GUARANTEED OUTPUT QUALITY • Even with typical distorting IT loads with crest factors of 3:1 • Increased short circuit current on the bypass • Increased overload capacity: 150% on inverter even when mains supply has failed • Reliable, filtered, stabilised and regulated sinewave output (double conversion technology VFI in conformity with IEC 62040-3 specifications) with filters for atmospheric disturbance suppression • Rephasing of load as the UPS has an input power factor close to 1, with a sinusoidal input current
ADVANCED COMMUNICATION • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. •The UPS is supplied with a communications cable for ‘Plug and Play’ PC connection • USB port • RS232 serial port • Interface card slot
HIGHLY RELIABLE BATTERY PERFORMANCE • Automatic and manual battery tests • Unique Low Ripple Current Discharge (LRCD) to help prolong battery life • Hot-swap user replaceable batteries
2 YEAR WARRANTY
DLD 330 DLD 400
DLD 500 DLD 600
USB port
DLD 800 DLD 1000 DLD 650 TM DLD 800 TM DLD 1000 TM
Serial port Interface card slot SNMP or additional RS232 ports Input thermal protection re-set Input SOKET
Output SOKETS
Battery extension pack connector
Input cable access Output cable access
TECHNICAL DETAILS 25
Dialog Dual 3.3-10 kVA
SIMPLIFIED INSTALLATION • The UPS can be installed as a floor standing tower or 19” rackmount UPS. The front panel digital display can be pulled out (using the keys provided) and rotated to suit the installation format • Low noise level (<40dBA) thanks to the digitally PWM controlled ventilation system which is load and temperature dependent, and the use of an inverter with a high switching frequency • Optional bolt-on maintenance bypass (DLD 5-6-8-10 kVA models) to allow service without disruption to the loads • Performance guaranteed in temperatures up to 40°C • Two IEC output plugs with thermal protection (DLD5-6-8-10 kVA). • PowerShare output socket (2x10A IEC) functionality on DLD 5-6-8-10 kVA models
MODELS POWER
DLD 330
DLD 400
DLD 500
DLD 600
DLD 800
DLD 1000
3300VA/2300W
4000VA/2400W
5000VA/3500W
6000VA/4200W
8000VA/6400W
10000VA/8000W
INPUT Rated voltage
220-230-240 Vac
Minimum voltage
164 Vac @ load 100% / 84 Vac @ load 50%
Rated frequency
50/60 Hz ± 5 Hz
Power factor
> 0.98
Current distortion
≤ 7%
BY PASS Voltage range
180 - 264 Vac (selectable in Economy Mode and Smart Mode)
Frequency range
Selected frequency ±5% (user configurable)
OUTPUT Rated voltage
220-230-240 Vac selectable
Voltage distortion
< 3% with linear load / < 6% with non-linear load
Frequency
50/60 Hz selectable
Static variation
1.5%
Dynamic variation
≤ 5% in 20 ms
Waveform
Sinewave
Dialog Dual 3.3-10 kVA
Crest factor
3: 1
BATTERIES Recharge time
4-6 h
OVERLOAD CAPACITY 100% < Load < 110%
1’
110% < Load < 150%
4”
Load > 150%
0.5”
ENVIRONMENTAL Weight (kg)
38
40
Dimensions (HxWxD) (mm)
455 x 175 x 520 tower 175(4U) x 483 x 520 rack
62
64
80
455 x 175 x 660 tower 175(4U) x 483 x 660 rack
2 x 455 x 175 x 660 tower 2 x 175(4U) x 483 x 660 rack
Efficiency
up to 98%
Protection
Overload - short-circuit - overvoltage - undervoltage - temperature - low battery
Communication Compliance
USB / RS232 + communication interface slot EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3
Operating temperature
0°C ÷ +40°C
Relative humidity
< 95% non condensing
Colour Noise Accessories provided
Dark grey < 40 dBA at 1 m
< 45 dBA at 1 m
2x10A cables; 1xIEC-16A plug; software; serial cable; plastic keys to release display; handles kit
2 cable guides; terminal board connection; software; serial cable; plastic keys to release display; handles kit
OPTIONS Extended runtime solutions Telescopic rails for rack cabinet
26
85
yes (with and without battery charger) yes
MODELS POWER
DLD 650 TM
DLD 800 TM
DLD 1000 TM
6500VA/5200W
8000VA/6400W
10000VA/8000W
INPUT Rated voltage
400 Vac three-phase + N
Minimum voltage (PH + N)
164 Vac @ load 100% / 84 Vac @ load 50%
Rated frequency
50/60 Hz ± 5 Hz
Power factor
> 0.95
BY PASS Voltage range
180 - 264 Vac (selectable in Economy Mode and Smart Mode)
Frequency range
Selected frequency ±5% (user configurable)
OUTPUT Rated voltage
220-230-240 Vac selectable
Voltage distortion
< 3% with linear load / < 6% with non-linear load
Frequency
50/60 Hz selectable
Static variation
1.5%
Dynamic variation
≤ 5% in 20 ms
Waveform
Sinewave
Crest factor
3: 1
Recharge time
Dialog Dual 3.3-10 kVA
BATTERIES 4-6 h
OVERLOAD CAPACITY 100% < Load < 110%
1’
110% ≤ Load < 150%
4”
Load > 150%
0.5”
ENVIRONMENTAL Weight (kg)
64
80
Dimensions (HxWxD) (mm)
85
2 x 455 x 175 x 660 tower / 2 x 175(4U) x 483 x 660 rack
Efficiency Smart Mode
up to 98%
Protection
Overload - short-circuit - overvoltage - undervoltage - temperature - low battery
Communication
USB / RS232 + communication interface slot
Compliance
EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3
Operating temperature
0°C ÷ +40°C
Relative humidity
< 95% non condensing
Colour
Dark grey RAL 7016
Noise
< 45 dBA at 1 m
Accessories provided
2 cable guides; terminal board connection; software; serial cable; plastic keys to release display; handles kit
BB 240-A3 BC 240-A5
BC 108-38
DLD 330-400
DLD 500-600
DLD 650TM-800-800TM-1000-1000TM
DLD 330-400 Tower
4U
Dimensions (mm) hxwxd
455
DLD MODEL
19 ’’ 17 5
520
19 ’’
0
52
17 5
660
630
BB 192-7 BC 192-12
4U
BB 108-7 - BC 108-14
455
BATT. BOX MODELS
0
66
21 5
655
4U = 176 mm; 19” = 438 mm
27
Local Area Networks (LAN)
ServerS
Data Centers
Cash Registers
Telecommunication devices
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Power Dialog 3 5-6 kVA
single/single-phase
6
6.5 -10 kVA
Power Dialog 3 5-10 kVA
single/single-phase and three/single-phase
Power Dialog 3 is the ideal solution for powering vital mission critical, sensitive loads such as electro-medical security applications in order to guarantee maximum reliability and availability. The series includes 5kVA-6kVA single/single phase and 6.5kVA8kVA-10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage. 28
Moreover, the input and output filters increase the immunity of the load against mains power disturbances and lightning strikes. Power Dialog 3 is without doubt one of the best UPS systems on the market today thanks to the technology used, the features (selectable Economy Mode and Smart Mode) and the diagnostics offered (custom LCD display, RS232 and USB interfaces complete with Powershield3 software, EPO contact and slots for optional interface boards).
Rear view
SIMPLIFIED INSTALLATION • The UPS can be connected to both single phase and three phase mains supplies. • Output terminal board + 2 IEC plugs to power local equipment (computers, modems, etc.). • Easy to move thanks to built-in wheels. HIGH BATTERY RELIABILITY • Automatic and manual battery tests. • Low Ripple Current Discharge system “LRCD” to prolong battery life. • Unlimited extendable runtime thanks to dedicated modular design Battery Boxes. • Increased ride-through for mains failures up to 40ms (high hold up time) and for fluctuations in the input current ranging from 84V to 276V).
OTHER FEATURES • Filtered, stabilised and reliable current (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference). • Advanced diagnostics: status, measurements and alarms available on the custom LCD display • Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter with high switching frequency (>20kHz, value above the audible range) • Autorestart when mains power returns, can be programmed using software or the digital front panel display • Emergency mode: the UPS can be programmed to work only when mains power fails (suitable for emergency lighting) • Standard back feed protection: to avoid current being fed back into the mains system. • Digital updating of the UPS (flash upgradable) HIGH UPS RELIABILITY • Full microprocessor control. • No break static and maintenance bypass. • Features guaranteed up to 40°C (the components are designed to operate at high temperatures and thus are subject to less stress at ordinary temperatures). SELECTABLE OPERATING MODES The operating mode can be programmed using the software or selected manually on the digital front panel display. • On line Mode (VFI). • Economy Mode: increases efficiency (up to 98%), and uses Line Interactive (VI) technology to power low priority loads from the mains supply. • Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply. • Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode). • Frequency converter Mode (50 or 60 Hz).
ADVANCED COMMUNICATION • Compatible with the Riello TeleNetGuard remote assistance system. • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. • RS232 serial port. • Plug and Play connection. • Slots for communication interface boards.
Display
HIGH QUALITY OUTPUT VOLTAGE • Even with distorting loads (IT loads with crest factor of up to 3:1). • High short circuit current on bypass. • High overload capacity: 150% on inverter, even when mains power fails. • Filtered, stabilised and reliable voltage (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference). • Rephasing of the load: UPS input power factor close to 1 with sinusoidal current absorption.
29
Power Dialog 3 5-10 kVA
LOW IMPACT ON MAINS POWER • Sinusoidal input current on single phase/single phase series.
MODELS POWER
PWN 500
PWN 600
PWN 650
PWN 800
PWN 1000
5000VA/4000W
6000VA/4200W
6500VA/5200W
8000VA/6400W
10000VA/8000W
INPUT Rated voltage
220-230-240 Vac single-phase
Minimum voltage without battery intervention
220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral
170 Vac @ load 100% / 140 Vac @ load 50%
Rated frequency
50/60 Hz ± 5 Hz
BY PASS Voltage range
180 - 264 Vac (selectable in Economy Mode and Smart Mode)
Frequency range
Selected frequency ±5 Hz
OUTPUT Rated voltage
220 - 230 - 240 Vac selectable
Voltage distortion
< 3% with linear load / < 6% with non-linear load
Frequency
50/60 Hz selectable or auto sensing
Static variation
± 1,5 %
Dynamic variation
≤ 5% in 20 ms
Waveform
Sinewave
Crest factor
≥ 3: 1
Power Dialog 3 5-10 kVA
BATTERIES Recharge time
6-8h
OVERLOAD CAPACITY 100% < Load < 125%
1’
110% ≤ Load < 150%
4”
Load ≥ 150%
0.5”
ENVIRONMENTAL Weight (kg)
89
90
91
Dimensions (HxWxD) (mm)
Communication Compliance
95
615 x 282 x 785
Efficiency Smart Mode Protection
94
up to 98% Overload - short-circuit - overvoltage - undervoltage - temperature - low battery RS232 + USB + remote contacts + communication interface slot EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3
Operating temperature
0°C ÷ +40°C
Relative humidity
< 95% non condensing
Colour
Dark grey RAL 7016
Noise
< 45 dBA at 1 m
OPTIONS Extended runtime solutions Isolation transformer box (HxWxD) mm/kg Product characteristics can be customised to meet client specifications.
30
yes (with and without battery charger) 500 x 400 x 265 / 80
-
ON/OFF switch
BATTERY BOX MODELS
communication interface slot Emergency Power Off (EPO)
Serial interface port IEC SOCKETS
Input switch (SWIN)
USB PORT
BB240-A3-A BB240-A5-A BB240-A7-A BC240-M1-A BC240-M5-A
Dimensions (mm) h x w x d
615
PWN 500 - PWN 600 PWN 650 - PWN 800 PWN 1000
785
28
2
Maintenance bypass (SWMB) Output switch (SWOUT)
Battery fuse holders (SWBT)
Power Dialog 3 5-10 kVA
TECHNICAL DETAILS
31
Local Area Networks (LAN)
ServerS
Data Centers
Cash Registers
Telecommunication devices
e-business (Servers Farms, ISP/ASP/POP)
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Multi Plus 10-20 kVA single-phase
6
10-40 kVA 100-120 kVA Multi Plus 10-40 /100-120 kVA
three-phase
MULTI PLUS is ideal for the protection of critical information and telecommunications networks which cannot run the risk of being powered from a poor quality electrical supply. The MULTI PLUS series is available in 10-12-15-20 kVA three-phase and single-phase input and single-phase output models, and 10-12-15-20-3040 and 100-120 kVA three-phase input and output models, with double conversion on-line technology according to the VFI-SS-111 classification, as defined by the IEC EN 62040-3 standard. Multi Plus has been designed and manufactured using state-of-the-art technologies in order to deliver maximum protection for critical users, a zero impact on the mains power supply and a high operating efficiency. 32
The high level of flexibility at the design stage means that there is full compatibility both with three-phase power and with single-phase sources, thus eliminating any critical factors in the connection between UPS and system. ZERO IMPACT SOURCE The superior technology of a Multi Plus UPS allows it be used where the site mains power supply is limited in capacity, or has an on-site generator and/or loads that generate current harmonic problems. Multi Plus is designed to have a zero-impact on its upstream power supply (mains or generator):
BATTERY CARE SYSTEM Battery management is one of the fundamentals of UPS management in order to ensure the system can perform in emergencies. The Multi Plus Battery Care System consists of a number of functions that together guarantee optimum battery performance. Battery recharge: Multi Plus is suitable for use with sealed Valve Regulated (VRLA), AGM, GEL and open-vented lead acid batteries, in addition to Nickel-Cadmium. Depending on the battery type used, the recharging functions can include: • One-level recharge, typical for the most commonly used VRLA AGM batteries • Two voltage level recharge according the IU characteristic • Charge blocking system to reduce consumption of the electrolyte and further extend the life of VRLA batteries. Compensation of the recharge voltage according to temperature in order to avoid excessive battery charging currents and potential overheating problems. Battery Test in order to detect battery performance deterioration or failure. Protection against deep discharges: during extended low load discharges, the end-of-discharge voltage is increased as recommended by battery manufacturers, to prevent damage to the battery set. Current Ripple: recharge current ripple (residual AC component) is one of the most common causes of poor battery performance and reduced operating life. Multi Plus, with its high-frequency battery-charger, produces negligible current ripple levels and therefore helps to extend operating life. Wide voltage range: the rectifier can operate from a wide input range (up to 40% at half load), reducing battery usage and helping to extend their operational life.
MLT 40 traditional UPS 40kVA 100 98 96 94 92 90 88 86 84 82 80 78 76 0
20 30 40
60
80
100
120
% load Display MLT 30-120
MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to operate in parallel even if one of the interconnecting communication cables is disconnected (closed loop).
Display MLT 10-20
ADVANCED COMMUNICATION Multi Plus is equipped with a graphic display that provides information, measures, states and alarms regarding the UPS in 5 different languages • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems • Compatible with the TeleNetGuard remote service monitoring system • RS232 or USB serial port • 3 slots for the installation of optional communication accessories such as network adapters and volt-free contacts • REPO (Remote Emergency Power Off) with which to power down the UPS through a remote emergency pushbutton • Input for connection of the auxiliary contact of an external manual bypass • Input for synchronisation from an external source • Graphic mimic panel display for remote connection
33
Multi Plus 10-40 /100-120 kVA
HIGH EFFICIENCY High operating efficiency up to 96.5% providing a 50% saving in energy usage per annum compared to traditional UPS products (92%). This exceptional performance can lead to a full initial investment recovery within three years. The efficiency values quoted were tested independently by TÜV Rheinland.
LOW MANAGEMENT COST The high performance components and technology used by Multi Plus means that the UPS achieves exceptional performance and efficiency levels, from a very small footprint and overall compact dimensions: • the lowest footprint in this category, only 0.26 m2 for 20kVA Multi Plus, batteries included • the type of input stage guarantees a power factor close to 1 and a low current distortion without the addition of filters, which can be expensive and bulky • output power factor of 0.9 providing up to 15% more active power than a traditional UPS and more load expansion
% Efficiency
• Input current distortion < 3% • Input power factor 0.99 • Power walk-in function to guarantee a progressive rectifier start-up • Delayed switch-on function, to sequentially restart the UPS when installed as part of a parallel system. Multi Plus also act as a filter and phase-shift protection device in respect to its upstream supply, providing protection from any harmonic components or reactive power generated by downstream loads.
(% PA UPS) P Q
CAPACITIVE Leading
100 80 60
P.F. 0.9
eg: 10 kVA UPS supplies 9 kW load
40
P.F. 1
20
eg: 10 kVA UPS supplies 9 kW load
% PA 0 25
50
75
100
(% P UPS) P
20
Multi Plus 10-40 /100-120 kVA
MLT/MLM 10-20
P.F. 0.9
40
FLEXIBILITY Multi Plus is suitable for use in a broad spectrum of applications, thanks to a variety of configurations, accessories and options providing flexibility and a choice of performance levels: • suitable for powering capacitive loads, such as blade servers, without any reduction in active power (0.9 lead to 0.9 lag) • multiple operating modes: On Line, Eco, Smart Mode and Stand By Off • Frequency converter mode • configurable Power Share connections to ensure backup for the most critical loads or programmed to operate only when mains power fails •Cold Start facility that starts the UPS even when it is not connected to the mains • MLT/MLM X version: in cabinet (1320x440x850 HWD) provides optimum solutions when medium or long term runtime is required • optional temperature sensor for external battery cabinets, to assist the recharge voltage compensation • additional battery chargers to optimise recharge times • optional dual input to mains power supply • isolation transformer options to vary neutral connectivity in the event of separate power sources or for galvanic isolation input and output • battery cabinets of various sizes and capacities to ensure prolonged runtime.
eg: 10 kVA UPS supplies 9 kW load
60 80
INDUCTIVE Lagging
100
(% PA UPS) P Q
MLT 100 - 120 PARALLEL CONNECTORS COMMUNICATION INTERFACE SLOT
ConneCtorS repo - AS400 USB - RS232
MLM 10 - 20 X MLT 10 - 40 X
repo - AS400 USB - RS232 connectors
COMMUNICATION INTERFACE SLOT
POWERSHARE sOCKETS BATTERY fuses
connectors Remote contacts
MLM 10 - 12 - 15 - 20 MLT 10 - 12 - 15 - 20 COMMUNICATION INTERFACE SLOT PARALLEL CONNECTORS Serial interface port
USB PORT
Maintenance bypass (SWMB) bypass SWITCH (SWBYP) MULTICOM 382 SLOT
Input switch (SWIN) Output switch (SWOUT) Bypass fuse holder (SWBYP) Input switch (SWIN)
Output switch (SWOUT) Maintenance bypass (SWMB)
POWERSHARE sOCKETS
TECHNICAL DETAILS 34
MODELS
MLM 10
MLM 12
MLM 15
MLM 20
INPUT Rated voltage
380-400-415 Vac three-phase with Neutral / 220-230-240 single-phase
Rated frequency
50/60 Hz
Frequency tolerance
40 ÷ 72 Hz
Power factor at full load
0.99
Current distortion
thdi ≤ 3%
BY PASS Rated voltage
220-230-240 Vac
Number of phases
1
Voltage tolerance
180 ÷ 264 V (selectable)
Rated frequency
50/60 Hz (selectable)
Frequency tolerance
±5 (selectable)
OUTPUT 10
12
Active power (kW)
8
9.6
Output power factor
0.8
Number of phases
1
Rated voltage (V)
15
20
12
16
Multi Plus 10-40 /100-120 kVA
Rated power (kVA)
220-230-240 Vac (selectable)
Static variation
± 1%
Dynamic variation
± 3%
Crest factor (Ipeak/Irms)
3: 1
Voltage distortion
≤ 1% with linear load / ≤ 3% with non-linear load
Frequency
50/60 Hz
Frequency stability on battery mode
0.01%
Overload at pF 0.8
110% for 10 minutes, 133% for 1 minute, 150% for 5 seconds
BATTERIES Type
VRLA AGM/GEL
Recharge time
6h
ENVIRONMENTAL Weight with internal batteries (Kg) Dimensions (HxWxD) (mm) Communication Operating temperature
180
182
190
930 x 320 x 840 / 1320 x 440 x 850 (version MLM X) 3 communication interface slots/RS232/USB O°C / +40°C
Relative humidity
90% non condensing
Colour
Dark Grey RAL 7016
Noise
< 52 dBA at 1 m
Protection rating Efficiency Smart Mode
Compliance
195
IP20 ≥ 98% in Economy mode European Directives: L V 2006/95/CE Low voltage directive EMC 2004/108/EC Electromagnetic compatibility directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
35
MODELS
MLT 10
MLT 12
MLT 15
MLT 20
MLT 30 X
MLT 40 X
MLT 100
MLT 120
INPUT Rated voltage
380-400-415 Vac three-phase with Neutral
Rated frequency
50/60 Hz
Frequency tolerance
40 ÷ 72 Hz
Power factor at full load
0.99
Current distortion
thdi ≤ 3%
BY PASS Rated voltage
380-400-415 Vac three-phase with Neutral
Number of phases
3+N
Voltage tolerance
180 ÷ 264 V (selectable)
Rated frequency
50/60 Hz (selectable)
Frequency tolerance
±5 (selectable)
Multi Plus 10-40 /100-120 kVA
OUTPUT Rated power (kVA)
10
12
15
20
30
40
100
120
Active power (kW)
9
10.8
13.5
18
27
36
90
108
460 (*)
480 (*)
Output power factor
0.9
Number of phases
3+N
Rated voltage (V)
380-400-415 Vac (selectable)
Static variation
± 1%
Dynamic variation
± 3%
Crest factor (Ipeak/Irms)
3: 1
Voltage distortion
≤ 1% with linear load / ≤ 3% with non-linear load
Frequency
50/60 Hz
Frequency stability on battery mode
0.01%
Overload at pF 0.8
115% unlimited, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds
BATTERIES Type
VRLA AGM/GEL
Recharge time
6h
ENVIRONMENTAL Weight with internal batteries (Kg) Dimensions (HxWxD) (mm)
180
182
190
195
335
930 x 320 x 840 1320 x 440 x 850 (MLT X version)
Communication
1320 x 440 x 850
O°C / +40°C
Relative humidity
90% non condensing
Colour
Dark Grey RAL 7016
Protection rating Efficiency Smart Mode
Compliance
(*) weight without batteries
36
1900 x 750 x 855
3 communication interface slots /RS232/USB
Operating temperature
Noise
350
< 52 dBA at 1 m
< 48 dBA at 1 m
< 65 dBA at 1 m
IP20 up to 99% European Directives: L V 2006/95/CE Low voltage directive EMC 2004/108/EC Electromagnetic compatibility directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
Multi Plus 10-40 /100-120 kVA BATTERY BOX MODELS
BB 480X-M5 BB 480X-M6 / BB 480-M7
MODEL
BB 480-B1
BB 480-B2
AB480-B0 MLM 10 - 12 - 15 - 20 MLT 10 - 12 - 15 - 20 - 30 - 40 100 - 120
MLM 10 - 12 - 15 - 20 MLT 10 - 12 - 15 - 20 - 30 - 40
440
0
85
650
750
1900
1600
1320
1600
Dimensions (mm) hxwxd
900
750
860
0
80
37
Local Area Networks (LAN)
ServerS
Data Centers
Cash Registers
Telecommunication devices
e-business (Servers Farms, ISP/ASP/POP)
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Multi Dialog mdt MDT 60-80 kVA three/three-phase
Multi Dialog MDT 60-80 kVA
4
38
BB BB576-B1
MOD. MDT
60
60-80
Dimensions (mm) hxwxd
50
0
740
BB BB 576-65M 576-80M
60-80
65
0
750
BB 576-100M
60-80
60-80
1900
BB 576-26M
1600
BATTERY BOXES
1600
LOW POWER CONSUMPTION • On-line Mode: up to 92% efficiency can be achieved due to the use of IGBT technology, increasing to 98% in one of the other operating modes • Economy Mode: uses Line Interactive (VI) technology to power less critical loads from the mains supply for certain periods • Smart Mode: if the mains supply is out of range, the UPS will power the load from the inverter as an On-line UPS. When the mains supply returns to within range again, the UPS will monitor this for a certain period before selecting Line Interactive operation
MAXIMUM RELIABILITY AND AVAILABILITY • Connect up to 8 units in parallel or N+1 redundancy, of even different power ratings
1400
The MULTI DIALOG series includes 60-80 kVA three-phase models, and uses double conversion on-line technology (VFI). The load is powered continuously by the inverter with a filtered, Stabilised and regulated sinewave supply. The input and output filters considerably increase the immunity of the load to mains disturbances and surges, even on bypass.
90
0
750
86
0
800
SENSITIVE SUPPLY COMPATIBLE For power supply sources that are particularly sensitive to harmonics (generator sets or transformers of low power with respect to that of the UPS) it is often a good idea to take action to limit the harmonics injected back into the supply by the UPS. MULTI DIALOG AF series have an active filter and use high frequency Insulate Gate Bipolar Transistor (IGBT) Technology with Digital Signal Processor (DSP) control. The Active Filter helps to reduce harmonics generated by the UPS into the supply which could disrupt the operation of upstream generators and transformers whose rating is closely matched to that of the UPS • Advanced technology Multi Dialog AF systems reduce harmonic distortion of the phase and neutral currents. The Digital Signal Processor (DSP) and the “current mode” instantly control and monitor the input current to maintain a perfect sinewave with 4% harmonic distortion • Maximum efficiency Multi Dialog AF systems have low input distortion even at low loads and their overall efficiency is not affected by generator frequency variations or line impedance • Reduction of neutral current Multi Dialog AF systems reduce the input neutral current by up to 3.5 times their nominal rating to help avoid oversizing input protections and conductors • Maximum reliability Multi Dialog AF systems are extremely reliable. Overall UPS performance is unaffected should the harmonic filter fail. • Excellent capabilities input distortion: (THDi) 4% input power factor: > 0.99 Multi Dialog can also be supplied without the Active Filter for installations less sensitive to current harmonics. OTHER CHARACTERISTICS • Suitable for powering capacitive loads such as blade servers, without any reduction of the active power, from 0.8 leading to 0.8 lagging • High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD in several languages • Reduced noise levels: high frequency inverter bridge • Back feed protection standard: to avoid energy feeding back into the mains supply (in compliance with CEI 11-20; DK5600) • Power factor correction (input power factor, close to 1) • By pass may be deactivated to allow operation as a frequency converter (at 50 or 60 Hz) • Emergency operation: the UPS can be set to operate only when the mains fails (for emergency lighting) ADVANCED COMMUNICATION • Compatible with TeleNetGuard for remote maintenance • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. • The UPS is supplied with a communications cable for ‘Plug and Play’ PC connection • Double RS232 serial ports • Network adapter slot for SNMP agent • Emergency Power Off (EPO) shutdown input contact • Remote control mimic panel
MDT MODELS
MDT60 - AF
MDT80 - AF
INPUT Rated voltage
400 Vac Three-phase + N
Voltage range
± 20%
Frequency range
45 ÷ 65 Hz
Power factor
>0.99
Current distortion
thdi 4%
BY PASS Rated voltage
400 Vac
Number of phases Permitted voltage range
3+N ± 15% (selectable from ± 5% a ± 25%)
Rated frequency Permitted frequency range
50/60 Hz ± 2% (selectable from ± 1% a ± 5%)
OUTPUT Rated power (kVA)
60
80
Active power (kW)
48
64
Number of phases Rated voltage (V)
3+N
Multi Dialog MDT 60-80 kVA
HIGH LEVEL BATTERY RELIABILITY • Automatic battery test • Recharge compensated for temperature • Automatic or manual rapid charge (boost) – duration progammable
380 - 400 - 415 V selectable
Voltage regulation range
346 ÷ 422 V
Crest factor (Ipeak/Irms)
3: 1
Waveform
Sinewave
Distortion with linear load
2%
Static stability
± 1%
Dynamic stability
± 5% in 10 ms
Frequency
50/60 Hz selectable
Overload
125% 150% of the rated current for 10’/1’
BATTERIES Type
Lead, flooded and VRLA AGM / GEL; NiCd
Recharge time
4-8 h
ENVIRONMENTAL Weight (kg)
180
192
Dimensions (HxWxD) (mm)
1400 x 500 x 740
Input
Three-phase + N
Remote signalling
Volt free contacts
Remote controls
EPO and Bypass
Communication
Double RS232/C + remote contacts + communication interface slot
Operating temperature Relative humidity Colour Noise Protection rating Efficiency Smart Mode
Compliance
O°C / +40°C < 95% non condensing Dark grey RAL 7016 < 56 dBA at 1 m
< 60 dBA at 1 m IP20
> 98.5 %
EN 62040-1 EMC EN 62040-2 EN 62040-3
39
Local Area Networks (LAN)
ServerS
Data Centers
Telecommunication devices
e-business
Industrial Processes
(Servers Farms, ISP/ASP/POP)
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Master Plus 100-800 kVA
three-phase/three-phase
Master Plus 100-800 kVA
6
ABSOLUTE PROTECTION Master Plus is an on-line double conversion UPS (VFI SS 111 in accordance with IEC EN 62040-3) with a transformer isolated inverter. Master Plus has a compact foot print and high quality output to provide the ultimate power protection for â&#x20AC;&#x153;mission criticalâ&#x20AC;? applications: data processing, tele-communications, industrial processes, security and electro-medical systems. EASY SOURCE Master Plus technology removes the problems of over sizing upstream power sources, whilst improving load power factors and current harmonics. The UPS features the latest input current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents. These features make Master Plus one of the most generator compatible and environmentally friendly UPS available.
Dimensions (mm)
800
40
0
80
12 MP 500 - 12 MP 600
0
85
1630
0
100
3200
0
98
1900
1900
1630
12 MP 800
1900
12 MP 400
1900
12 MP 300
1900
MP 100 - MP 120 MP 160 - MP 200
4400
0
100
MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 8 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to operate in parallel even if one of the interconnecting communication cables is disconnected (closed loop). OPTIONS • UGS - UPS Group Synchroniser Allows 2 or more UPS not in parallel to remain synchronised even during a power failure. The UGS also enables a RIELLO UPS to be synchronised with an independent power source, even of a different power rating. • PSJ - Parallel Systems Joiner Connects two UPS groups operating in parallel configurations through a power coupling switch. The Slave UPS Group is permanently synchronised to the Master group. Should one of the UPS in one of the parallel groups fail, the PSJ will automatically connect the remaining UPS to the other group via an external bypass EASE OF INSTALLATION Master Plus is compact with a foot print of only 0.64 m2 for a 200kVA system. Front access to internal assemblies and top panel ventilation make space allocation within confined data processing or plant rooms easy. Master Plus can be placed against a wall as there is no requirement for rear or side panel access for maintenance or ventilation.
FLEXIBILITY Master Plus is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, without any reduction in active power, from 0.9 leading to 0.8 lagging. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Riello UPS Group Synchroniser (UGS) and Parallel Systems Joiner (PSJ) sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability.
(% PA UPS) P Q
100
CAPACITIVE Leading
80 60
P.F. 0.9 40
eg: 100 kVA UPS supplies 80 kW load
20
P.F. 1
Master Plus 100-800 kVA
BATTERY CARE SYSTEM: MAXIMUM LIFETIME POTENTIAL Traditionally, when a mains supply is present the UPS charges its batteries. Battery power is used for the inverter should the input supply fail. Efficient battery management and care is therefore essential to the overall performance of the UPS in an emergency. The Master Plus Battery Care System consists of a range of features designed to provide optimum performance and enhanced operating life: • Dual level charging regime to optimise recharge currents and lower recharge times • Temperature compensation and deep discharge protection to reduce overall battery aging • Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries • Predictive battery testing to spot potential battery deterioration and failure Master Plus is also compatible with different battery technologies: open-vented lead acid and AGM and Gel VRLA, NiCd.
eg: 100 kVA UPS supplies 80 kW load
% PA 0 25
50
75
100
(% P UPS) P
20 40 60 80 100
P.F. 0.8
eg: 100 kVA UPS supplies 80 kW load
INDUCTIVE Lagging
(% PA UPS) P Q
Master Plus 400 kVA
41
SPECIFIC SOLUTIONS The UPS can be adapted to your requirements. Please contact TEC to discuss specific applications and options. ADVANCED COMMUNICATION • Compatible with TeleNetGuard for remote maintenance • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. The UPS is supplied with a cable for direct connection to the PC (Plug and Play)
1. Parallel configuration of up to 8 units with separate batteries
• Double RS232 serial port • Installation slot for an Emergency Power Off (EPO) interface to allow the UPS to be switched off remotely in an emergency. • Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charger.
2. Parallel configuration of up to 8 units with a common batteries Bypass mains
Bypass mains Mains
Mains
Mains
UPS1
Mains
UPS2
UPS3...
UPS8
Battery
Battery
UPS8
Maintenance Bypass Cabinet
Maintenance Bypass Cabinet
Load
Load
3. Dynamic dual bus configuration
4. Dual bus system configuration
Mains
UPS1A
Bypass 2
Mains
UPS2A
Mains
UPS1B
UPS2B
System A
Bypass 1
Mains
Bypass 2
Mains
UPS2A
Mains
UPS1B
UPS2B
Battery
UGS Sinchroniser
Battery
Battery
Battery
UPS1A
Battery
System B Mains
Battery
System B
Bypass 1
Mains
Battery
System A
Battery
Master Plus 100-800 kVA
UPS3...
Battery
UPS2
Battery
UPS1
Mains
Mains
PSJ
Static Transfer SWiTCH
Load 3 Load 1
Static Transfer SWiTCH
Load 2 Load 1
Load 4
42
Load 2
MODELS POWER (kVA)
MP 100
MP 120
MP 160
MP 200
100
120
160
200
INPUT Nominal voltage
380 - 400 - 415 Vac three-phase
Voltage tolerance
400 V + 20% /- 25%
Frequency
45 ÷ 65 Hz
Soft start
0 ÷ 100% in 30’’ (selectable)
Permitted frequency tolerance
± 2% (selectable from ± 1% to ± 5% from the front panel)
Standard features
Back Feed protection; separable bypass line
BATTERIES Type
Lead, flooded and VRLA AGM / GEL; NiCd
AC ripple
< 1%
Temperature compensation
-0.5 Vx°C
Typical charging current
0.2 x C10
OUTPUT Rated power (kVA)
100
120
160
200
Active power (kW)
80
96
128
160
Number of phases
3+N 380 - 400 - 415 Vac three-phase + N
Static stability
Master Plus 100-800 kVA
Nominal voltage
± 1%
Dynamic stability
± 5% in 10 ms
Voltage distortion
< 1% with linear load / < 3% with no-linear load
Crest factor (lpeack/lrms)
3:1
Frequency stability on battery mode
0.05%
Frequency
50/60 Hz (selectable)
Overload
110% for 60’; 125% for 10’; 150% for 1’
ENVIRONMENTAL Weight (kg) Dimensions (HxWxD) (mm) Remote signalling Remote commands Communication Operating temperature Relative humidity
640
650
770 1900 x 800 x 800 Voltage-free contacts EPO and bypass
double RS232 + remote contacts + 2 communication interface slots 0°C ÷ +40°C < 95% non condensing
Colour
Light grey RAL 7035
Noise
63 ÷ 68 dBA at 1 m
Protection rating Efficiency Smart Mode
Compliance
810
IP20 Up to 98% European Directives: L V 2006/95/CE Low voltage directive EMC 2004/108/EC Electromagnetic compatibility directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
43
MODELS POWER (kVA)
12 MP 300
12 MP 400
12 MP 500
12 MP 600
12 MP 800
300
400
500
600
800
INPUT Nominal voltage
380 - 400 - 415 Vac three-phase
Voltage tolerance
400 V + 20% /- 25%
400 V ± 20%
Frequency
45 ÷ 65 Hz
Power factor
> 0.95 in HC version
> 0.93 in HC version
Current distortion
< 3% in HC version
Soft start
0 ÷ 100% in 30’’ (selectable)
Permitted frequency tolerance
± 2% (selectable from ± 1% to ± 5% from the front panel)
Standard features
Back Feed protection; separable bypass line
BATTERIES Type
Lead, flooded and VRLA AGM / GEL; NiCd
AC ripple
< 1%
Temperature compensation
-0.5 Vx°C
Typical charging current
0.2 x C10
Master Plus 100-800 kVA
OUTPUT Rated power (kVA)
300
400
500
600
800
Active power (kW)
240
320
400
480
640
4000
5300
Number of phases
3+N
Nominal voltage
380 - 400 - 415 Vac three-phase + N
Static stability
± 1%
Dynamic stability
± 5% in 10 ms
Voltage distortion
< 1% with linear load / < 3% with no-linear load
Crest factor (lpeack/lrms)
3:1
Frequency stability on battery mode
0.05%
Frequency
50 or 60 Hz (selectable)
Overload
110% for 60’; 125% for 10’; 150% for 1’
ENVIRONMENTAL Weight (kg) Dimensions (HxWxD) (mm)
2200
2600
1900 x 1630 x 850
1900 x 1630 x 1000
Remote signalling
double RS232 + remote contacts + 2 communication interface slots 0°C ÷ +40°C
Relative humidity
< 95% non condensing
Colour
Protection rating Efficiency Smart Mode
Compliance
44
1900 x 4400 x 1000
EPO and bypass
Operating temperature
Noise
1900 x 3200 x 980 Voltage-free contacts
Remote commands Communication
3600
Light grey RAL 7035 < 70 dBA at 1 m
< 77 dBA at 1 m IP20 Up to 98%
European Directives: L V 2006/95/CE Low voltage directive EMC 2004/108/EC Electromagnetic compatibility directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
< 80 dBA at 1 m
OPTIONS Isolation transformer module UPS Group Syncroniser (see UGS) Hot connection device (see PSJ) Interface for generator Closed Loop parallel kit option (to be ordered with the UPS)
Master Plus 100-800 kVA
Empty or full battery cabinets for prolonged runtime
BATTERY BOX MODELS
BB 396-J8 BB 396-J9 BB 396-K1 BB 396-K2
BB 480-A0
ISOLATION TRANSFORMER MODULE
MP MODELS
MP 100-200
MP 300-400
MP MODELS
TT 100 TT 120 TT 160
TT 200
TT 250 TT 300
MP 100-160
MP 200
12 MP 300
86
0
0
80
(mm)
hxwxd
64 0
0
80
1900
1900
hxwxd
1900
(mm)
1900
Dimensions
Dimensions
80
0
0
80
83
0
0
85
45
Local Area Networks (LAN)
ServerS
Data Centers
Telecommunication devices
e-business (Servers Farms, ISP/ASP/POP)
Industrial Processes
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Master Plus HIP 100-250 kVA
6
Master Plus HIP 100-250 kVA
three-phase/three-phase
The new HIP version available in 100 to 250kVA models has been added to the Master Plus series. Thanks to the double conversion on-line technology achieved entirely with IGBT and DSP (Digital Signal Processor) control, the Master Plus HIP series guarantees maximum protection as well as high quality power for any type of IT and industrial load. It is especially suited for 46
mission critical applications and is classed VFI SS 111 (Voltage and Frequency Independent) in compliance with IEC EN 62040-3 standards. This series has been designed using a new configuration that includes an IGBT rectifier with sinusoidal input current in place of the traditional thyristor rectifier.
Details of the connection
FLEXIBILITY Master Plus models (including the HIP versions) feature an output transformer with galvanic isolation (between the load and the battery supply) to provide greater versatility and installation options. The UPS can be supplied from two separate power sources (mains power and a second emergency standby source) which can help increase the resilience of parallel system configurations. MAIN CHARACTERISTICS • Efficiency up to 98 % • Compact footprint: only 0.85 m2 for the 250kVA UPS model • Reduced weight • Double electronic and galvanic protection of the load from the battery
BATTERY CARE SYSTEM Master Plus HIP uses the Battery Care System, also available on the traditional Master Plus models, which optimises battery performance in order to extend the battery life for as long as possible.
The entire Master Plus HIP range is suitable for a wide range of applications thanks to the flexibility of the configurations, accessories and options and choice of performance levels: compatible with capacitive loads, such as blade servers, without any reduction in active power, ranging from 0.9 lead to 0.8 lag and up to 0.8 capacitive power with a low derating equal to 15% of the active power (kW). Efficient and reliable power supply for mission critical applications is guaranteed by operating in redundancy and power parallel mode with up to 8 units (N+1), and by the Dual Bus System and Dynamic Dual Bus system configurations.
OPTIONS Isolation transformer Synchroniser device (see Master Plus UGS) Parallel Systems Joiner device (see Master Plus PSJ) Interface for generator set Closed Loop kit (to be ordered with the UPS) Empty battery cabinets or cabinets for extended runtime (Battery Box modules BB 480 A0) (Master Plus) 47
Master Plus HIP 100-250 kVA
ZERO IMPACT SOURCE Master Plus HIP is a further evolution of the Master Plus series with the added advantages offered by an IGBT-based rectifier assembly. This feature further reduces the impact of the UPS on the local supply and simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size. Master Plus HIP is classed as a ‘Zero Impact Source’ and provides: • low input current distortion – less than 2.5% • high input power factor 0.99 • power walk-in function that ensures progressive rectifier start up • delayed start up phased with the return of mains power supply, when several UPS are connected in the system. Master Plus HIP also performs the role of a high performance filter, protecting its upstream power supply sources from any harmonics and reactive power generated by the loads powered.
MODELS POWER (kVA)
MP 100-HIP
MP 120-HIP
MP 160-HIP
MP 200-HIP
MP 250-HIP
100
120
160
200
250
INPUT Nominal voltage
380 - 400 - 415 Vac three-phase
Range acceptable without battery intervention
300÷480 Vac
Frequency
45÷65 Hz
Power factor
> 0,99
Current harmonic distortion
<2.5% THDi
Soft start
0÷100 in 30” (selectable)
Frequency tolerance
± 2% (selectable between ± 1% a ± 5% from the front panel)
Standard fittings
Back Feed protection; separable bypass line
BATTERIES Type
Free lead-acid, and VRLA AGM / GEL; NiCd
Ripple current
Zero
Recharge voltage compensation
-0.5 Vx°C
Master Plus HIP 100-250 kVA
OUTPUT Nominal power (kVA)
100
120
160
200
250
Active power (kW)
80
96
128
160
200
910
1000
Number of phases
3+N
Nominal voltage
380 - 400 - 415 Vac 3-phase + N
Static stability
± 1%
Dynamic stability
± 5% in 10 ms
Voltage distortion
< 1% with linear load / < 3% with distorting load
Peak factor (lpeak/lrms)
3:1
Frequency stability on battery
0.05%
Frequency
50 or 60 Hz (selectable)
Overload
110% for 60’; 125% for 10’; 150% for 1’
ENVIRONMENTAL Weight (kg) Dimensions (lxdxh) (mm) Remote reports Remote commands Communication Environment temperature Relative humidity
656
700
800
1900 x 800 x 850
1900 x 1000 x 850 Voltage-free contacts (configurable) EPO and bypass (configurable)
Twin RS232 + remote contacts + 2 slots for communication interface 0°C ÷ +40°C < 95% non-condensing
Colour
RAL 7035 light grey
Noise level
63 ÷ 68 dBA at 1 m
Index of protection Efficiency Smart Mode Compliance Classification according to IEC 62040-3
48
IP20 (others on request) Up to 98% Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC) (Voltage Frequency Independent) VFI - SS - 111
49
Master Plus HIP 100-250 kVA
Industrial PLCs
Industrial Processes
Master Plus Industrial 30-80 kVA
Master Plus Industrial 30-80 kVA
three-phase/single-phase DC BUS 220 Vdc
PROTECTION FOR INDUSTRIAL APPLICATION Master Plus Industrial is an on-line double conversion UPS (VFI SS 111 in accordance with IEC EN 62040-3) with a transformer isolated inverter and rectifier. Master Plus Industrial has a compact foot print and high quality output to provide the ultimate power protection for industrial applications: industrial and petrochemical processes, power plants and energy distribution systems.
Dimensions (mm) MPI 30 - MPI 40
220V DC VOLTAGE An input transformer and isolated inverter to protect the 220Vdc bus bar (from 108 to 114 blocks), the recognised industrial standard. 50
1900
HIGH Icc A high short-circuit current (Icc = 3 In) making the UPS suitable for loads with high current peaks; during switch-on or a load step-change.
MPI 60 - MPI 80
800
0
80
1900
INDUSTRIAL ENVIRONMENT Master Plus Industrial is suitable for severe installation environments such as petrochemical manufacturing sites, where the operating conditions (levels of vibration, mechanical stress, ambient temperatures and dust ingress) require a more robust and industrialised UPS design to those installed within, for example, data centres.
1600
0
80
The Easy Source input, the Battery Care System as well as the flexibility and communication features are the same as those offered on the traditional Master Plus series.
REDUNDANT VENTILATION 100% redundant ventilation with 50% fan loading at nominal load and each fan monitored for breakdown or failure.
MODELS POWER (kVA)
MPI 30
MPI 40
MPI 60
MPI 80
30
40
60
80
INPUT Nominal voltage
380 - 400 - 415 Vac three-phasee
Voltage tolerance
400 V ± 20%
Frequency
45 ÷ 65 Hz
Power factor
≥ 0.93
Current distortion
< 5% C
Soft start
0 ÷ 100% in 30’’ configurable ± 2% (selectable from ± 1% to ± 5% from the front panel)
Standard features
Master Plus Industrial 30-80 kVA
Permitted frequency tolerance
Back Feed protection; separable bypass line
BATTERY Number of cells
108 ÷ 114
Max Vdc
274 V
Temperature compensation
-0,5 Vx°C
OUTPUT Rated power (kVA)
30
40
60
80
Active power (kW)
24
32
48
64
Nominal voltage
230 Vac single phase
Static stability
± 1%
Dynamic stability
± 5%
Voltage distortion
< 1% with linear load / < 3% with distorting load
Frequency
50 or 60 Hz configurable
Peak factor
3:1
Overload
110% for 60’; 125% for 10’; 150% for 1’
Short circuit current
3 Inom.
SYSTEM Remote signalling
Voltage-free contacts
Remote commands
EPO and bypass
Communication
double RS232 + remote contacts + 2 communication interface slots
Efficiency
Up to 94%
Dimensions (HxWxD) (mm) Weight (kg)
1900 x 800 x 800 850
1900 x 1600 x 800 900
1400
Noise level
63 ÷ 68 dBA a 1 m
Ventilation
Redundant fans
Operating temperature
0 °C ÷ +40 °C
Relative humidity
< 95% non condensing
Protection rating
IP20
Colour Compliance Classification according to IEC 62040-3
1500
RAL 7035 Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC) (Voltage Frequency Independent) VFI - SS - 111
51
Industrial PLCs
Industrial Processes
Master Plus 400 Hz 30-120 kVA
Master Plus 400 Hz 30-120 kVA
three-phase/three-phase
Master Plus FC 400 series is a frequency converted based on the Master Plus UPS that can accept 50/60Hz and deliver a 400Hz output. The device has a double-conversion design (VFI SS 111 compliant with IEC EN 62040-3) with a transformer-isolated Inverter. The output voltage is 208Vac and configurable at 200Vac on site with a 115Vac version available on request. The basic design is a solid state generator with IGBT- based Inverter controlled using PWM techniques. It is ideal for applications such as avionic repair workshops, hangars, aircraft ground power in civil airports and military bases.
52
MP 60 FC 400 - MP 80 FC 400 MP 100 FC 400 - MP 120 FC 400
1900
MP 30 FC 400
1200
MINIMUM IMPACT ON POWER SUPPLY â&#x20AC;&#x201C; EASY SOURCES MP FC 400 technology removes the problems of over sizing upstream power sources, whilst improving load power factors and current harmonics. The UPS features the latest input current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents. These features make MP FC 400 one of the most generator compatible and environmentally friendly UPS available.
Dimensions (mm)
550
740
800
0
80
OPTIONS • Input Isolation transformer • 2 Programmable relay cards • LED remote status panel • LCD based remote Control panel • Remote Graphics Panel • Input Isolation transformer • Protection degrees higher than IP20
EASY TO INSTALL MP FC 400 is compact with a foot print of only 0.64 m2. Front access to internal assemblies and top panel ventilation make space allocation within confined data processing or plant rooms easy. MP FC 400 can be placed against a wall as there is no requirement for rear or side panel access for maintenance or ventilation. APPLICATIONS • Aircraft ground power • Airports • Navy • Military equipment • Testing laboratories
POWER (kVA)
MP 30 FC 400
MP 60 FC 400
MP 80 FC 400
MP 100 FC 400
MP 120 FC 400
30
60
80
100
120
80
100
120
64
80
96
Master Plus 400 Hz 30-120 kVA
MODELS
The Easy Source input, the Battery Care System as well as the flexibility and communication features are the same as those offered on the traditional Master Plus series.
INPUT Nominal voltage
380 - 400 - 415 Vac three-phase
Voltage tolerance
400 V ± 20%
Frequency
45 ÷ 65 Hz
Power factor
≥ 0.93 (HC Version)
Current distortion
< 5% C (HC Version)
Soft start
0 ÷ 100% in 120’’ configurable
OUTPUT Rated power (kVA)
30
60
Active power (kW)
24
48
Nominal voltage
230 Vac three-phase + Neutral
Static stability
± 1%
Dynamic stability
± 5%
Voltage distortion
< 3% with linear load / < 4% with distorting load
Frequency
400 Hz
Peak factor
3:1
Overload
110% for 60’; 125% for 10’; 150% for 1’
SYSTEM Remote signalling
Voltage-free contacts
Remote commands
EPO and ON/OFF
Communication
double RS232 + remote contacts + 2 communication interface slots
Efficiency Dimensions (HxWxD) (mm) Weight (kg) Noise level Operating temperature
Up to 92% 1200 x 550 x 740 330
1900 x 800 x 800 480
500
0 °C ÷ +40 °C (50°C @ 75% load) < 95% non condensing
Protection rating
IP20 (other on request)
Compliance Classification according to IEC 62040-3
560
61 ÷ 63 dBA at 1 m
Relative humidity
Colour
530
RAL 7035 light grey Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC) (Voltage Frequency Independent) VFI - SS - 111
53
Data Centers
e-business (Servers Farms, ISP/ASP/POP)
Telecommunication devices
Industrial PLCs
Electromedical Devices
Emergency Devices (lights/Alarms)
Master Dialog
4
Master Dialog RM / RT
RM 8-100 kVA three-phase/single-phase RT 10-80 kVA three-phase/three-phase
MASTER DIALOG provides maximum protection for industrial applications thanks to its outstanding mechanical and electrical design. The load is powered continuously by the inverter with a filtered, stabilised and regulated sinewave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges. MASTER DIALOG is supplied with PowerShield3 software as standard and can be remotely monitored using the TeleNetGuard system from anywhere in the world. Additional battery extension packs allow the standard battery runtime to be extended up to several hours. 54
MASTER DIALOG series includes 8-100kVA three/single-phase and 10-80 kVA three-phase models and uses double conversion on-line technology (VFI) with an isolation transformer on the inverter output. HIGH RELIABILITY • Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. • Full microprocessor control with no-break static and manual bypasses, • IGBT technology
MINIMUM IMPACT ON THE MAINS Input current distortion <4% for the Master Dialog “Clean” version with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enables Master Dialog to deliver maximum performance levels regardless of the installation environment. With these input features Master Dialog can achieve significant savings in terms of sizing and power supply sources - isolation transformers and generators over less sophisticated power systems.
SIMPLE TO INSTALL • Capability to install the UPS into any distribution system (neutral not required on rectifier input) • Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation (necessary on UPS without an output transformer) • Option to regulate the output voltage and offset voltage drops down long cable runs
ADVANCED COMMUNICATION • Compatible with TeleNetGuard for remote maintenance • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. The UPS is supplied with a cable for direct connection to the PC (Plug and Play) • RS232 serial port • Volt-free signal contacts • EPO (Emergency Power Off) shutdown input contact • Input for switching to bypass by remote signal • LCD or LED-based remote control panel • Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charger.
MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 8 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to operate in parallel even if one of the interconnecting communication cable is disconnected (closed loop). LOW CONSUMPTION LEVELS Master Dialog can achieve efficiencies >98% thanks to a selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity should the mains fail OTHER CHARACTERISTICS • 0.8 power factor makes Master Dialog suitable for powering ICT and industrial loads • High level diagnostics: event log with 128 messages, states, measure ments and alarms - available from the built-in LCD in several languages • Back Feed protection: to avoid energy feeding back into the mains supply should a fault occur
SPECIFIC SOLUTIONS The UPS can be adapted to your requirements. Please contact TEC to discuss specific applications and options.
OPTIONS Isolation transformer module Remote control panel Closed Loop parallel kit option (to be ordered with the unit) Empty battery cabinets for prolonged runtime
BB 384-65B
10-15-20-30-40-60
RT MODELS
10-15-20-30-40
55
5
720
384-80D
384-100D
384-120D
60-80
30-40-60-80
30-40-60-80
60-80
15-20-30-40
60-80
30-40-60-80
30-40-60-80
60-80
55
5
720
1200
hxwxd
384-65D
15-20-30-40 60
1200
Dimensions (mm)
BB 384-38C
1400
BB 384-38A
RM MODELS
1400
BATTERY BOX
86
0
720
86
0
720
55
Master Dialog RM / RT
MAXIMUM BATTERY CARE • Temperature compensating charger • Battery deep discharge protection • Built-in automatic and manual battery test feature
RM MODELS
RM 8
RM 10
RM 15
RM 20
RM 30
RM 40
RM60
RM 80
RM 100
POWER (kVA)
8
10
15
20
30
40
60
80
100
INPUT Rated voltage (V)
400 Vac three-phase
Voltage range
± 20%
Frequency range
45 ÷ 65 Hz
Power factor
> 0.92 in RM CLEAN version
Distortion of the current absorbed
< 5% in RM CLEAN version
Soft start
0-100% in 10”
BY PASS Rated voltage (V)
230 Vac single-phase
Permitted voltage range
± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency
50/60 Hz (autorange)
Permitted frequency range
± 2% (selectable from ± 1% to ± 5% from front panel)
Standard features
Back Feed protection; separate bypass line
BATTERIES Type
Maintenance-free lead-acid VRLA AGM / GEL; NiCd
Maximum recharge current (A)
0.2 x C10
Master Dialog RM / RT
RECTIFIER OUTPUT Maintenance voltage
Variable acc. to temperature (-0.5 Vx°C)
Ripple
< 1%
INVERTER OUTPUT Rated power (kVA)
8
10
15
20
30
40
60
80
100
Rated voltage (kW)
6.4
8
12
16
24
32
48
64
80
174
261
348
434
Number of phases
1
Rated voltage (V) Rated current (A)
230 single-phase 35
43
65
87
Regulation of the output voltage
130
220 ÷ 244 V (configurable from control panel)
Crest factor (Ipeak/Irms)
3: 1
Waveform
Sinewave
Static stability
± 1%
Dynamic stability
± 5% in 5 ms
Frequency
50/60 Hz configurable
Overload
110% 125% 150% of the rated current for 5h/10’/1’
Frequency stability
± 0.05% on mains failure; ± 2% (selectable from ± 1% to ± 5%) with mains supply present
ENVIRONMENTAL Weight (kg)
190 to 460
200 to 470
Dimensions (HxWxD) (mm)
220 to 490
230 to 500
290
340
1200 x 555 x 720 Volt free contacts
Remote controls
EPO and Bypass
Communication
RS232 + remote contacts
< 95% non condensing
Colour
Light grey RAL 7035 54 dBA at 1 m
60 dBA at 1 m
Protection rating
up to 98%
Compliance
56
65 dBA at 1 m IP20
Efficiency Smart Mode
Internal batteries
650 1400 x 1070 x 740
0°C ÷ +40°C
Relative humidity
Noise
520
1400 x 800 x 740
Remote signalling
Operating temperature
440
Safety EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC 2004/108/EC; EN 62040-3 yes
yes
yes
yes
no
no
no
no
no
RT MODELS
RT 10
RT 15
RT 20
RT 30
RT 40
RT 60
RT 80
POWER (kVA)
10
15
20
30
40
60
80
INPUT Rated voltage (V)
400 Vac three-phase
Voltage range
± 20%
Frequency range
45 ÷ 65 Hz
Power factor
> 0.9 in RT CLEAN version
Distortion of the current absorbed
< 5% in RT CLEAN version
Soft start
0-100% in 10”
BY PASS Rated voltage (V)
400 Vac three-phase
Permitted voltage range
± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency
50/60 Hz auto sensing
Permitted frequency range
± 2% (selectable from ± 1% to ± 5% from front panel)
Standard features
Back Feed protection; separate bypass line
BATTERIES Type
Maintenance-free lead-acid VRLA AGM/GEL; NiCd
Maximum recharge current (A)
0.2 x C10
Maintenance voltage
Master Dialog RM / RT
RECTIFIER OUTPUT Variable acc. to temperature (-0.5 Vx°C)
Ripple
< 1%
INVERTER OUTPUT Rated power (kVA)
10
15
20
30
40
60
80
Rated voltage (kW)
8
12
16
24
32
48
64
58
87
115
Number of phases
3+N
Rated voltage (V) Rated current (A)
400 14
22
29
Regulation of the output voltage
43 348 ÷ 424 V (from control panel)
Crest factor (Ipeak/Irms)
3: 1
Waveform
Sinewave
Static stability
± 1%
Dynamic stability
± 5% in 5 ms
Frequency
50/60 Hz configurable
Overload
110% 125% 150% of the rated current for 5h/10’/1’
Frequency stability
± 0.05% on mains failure; ± 2% (selectable from ± 1% to ± 5%) with mains supply present
ENVIRONMENTAL Weight (kg)
210 to 480
220 to 490
Dimensions (HxWxD) (mm)
230 to 500
282 to 552
1200 x 555 x 720 Volt free contacts
Remote controls
EPO and Bypass
Communication
RS232 + remote contacts
Operating temperature
450
555
1400 x 800 x 740
Remote signalling
0°C ÷ +40°C
Relative humidity
< 95% non condensing
Colour
Light grey RAL 7035
Noise
54 dBA at 1 m
60 dBA at 1 m
Protection rating
62 dBA at 1 m
IP20
Efficiency Smart Mode
up to 98%
Compliance Internal batteries
330
Safety EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC 2004/108/EC; EN 62040-3 yes
yes
yes
no
no
no
no 57
ServerS
Multi Switch
Multi Switch
Ouput 1 max 4 A
Ouput 2 max 4 A
Ouput 3
Multi-SWITCH is a rackmount source transfer switch that can supply up to eight loads from two AC power sources. Should one source fail, the other automatically powers the load. The sources can be two separate AC sources including mains power and UPS, or a combination of the two.
max 4 A
Ouput 4 Input 1
max 4 A
Ouput 5 Input 2
max 4 A
Ouput 6 max 4 A
Ouput 7 max 4 A
Ouput 8 max 4 A
58
PRINCIPLE OF OPERATION The Multi-SWITCH provides electrical distribution and remote management for up to eight network users, powered from two direct mains supplies or UPS or a combination of both. The Multi-SWITCH can connect each user (up to eight, each with a maximum power demand not greater than 4A), to either of the two power sources (1 and 2). Load demand is shown on the LCD. See “principle of operation” diagram. PROTECTION AGAINST POWER SUPPLY FAILURES If one of the two power source fails or falls outside specification, MultiSWITCH will transfer the connected loads to the second power source (switching is instantaneous even if the two sources are not in phase). PROTECTION AGAINST LOAD FAULTS If a fault occurs with one of the loads (for example due to a shortcircuit or overload), Multi-SWITCH will disconnect the load to prevent disruption to the others. Multi-SWITCH protects sensitive installations from both power and hardware faults.
CHARACTERISTICS • Full protection against mains failures and load faults • Flexible power sources: Multi-SWITCH can be powered from 2 different sources (2 mains supplies, 2 UPS or a combination of both. Note than the UPS can be of a different size) • Designed for installation in a 19” rack-mount cabinet • LCD to provide measurements/alarms/states information • Management software included • Remote monitoring serial interface • No signal connection is required between Multi-SWITCH and the power sources or supplied hardware • Configuration software provided as standard • Slot-in SNMP network adapter card
MSW (2 input - 8 output) FRONT
output socket
BACK
ETHERNET version “N”
Serial RS232 version “S”
Input thermal protection RESET
input socketS
TECHNICAL DETAILS
MODELS
MSW-S / MSW-N 8 x 4A output sockets
INPUT Input voltage Rated frequency Maximum load for each input (A) Input sockets
180 - 276 Vac 50/60 Hz 16 2 IEC 320 (16A)
OUTPUT
Maximum load for each output (A) Output sockets
Selection of one of the two input sources 4 8 IEC 320 10A
Multi Switch
Output voltage
ENVIRONMENTAL Weight (kg)
10
Dimensions (HxWxD) (mm)
2U x 19” x 360
Operating temperature
0°C ÷ +40°C
Relative humidity Protection Compliance Maximum altitude Max. altitude (storage conditions) Communication Enclosure protection rating
< 95% non condensing Overcurrent - overvoltage - undervoltage - back-feed protection EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108/EC; EN 62040-3 3000 m 6000 m; 45 °C RS232 in MSW-S / Ethernet in MSW-N IP 20
Colour
Dark grey RAL 5004
Noise
< 35 dBA at 1 m
Product characteristics can be customised to meet client specifications.
59
ServerS
Master Switch
Master Switch
MASTER SWITCH is a static transfer switch commonly used within power continuity applications to improve resilience. The system can be used in conjunction with UPS or as separate standalone devices. OPERATING PRINCIPLE MASTER SWITCH adds a source of redundancy to a critical installation and automatically transfers the connected load between two separate AC power sources. The transfer can be automatic when an input power 60
supply fails outside set tolerances or be manually forced using the front panel keypad or remotely via a communications network. PROTECTION AGAINST POWER FAILURES In the event that one of the two power sources does not return to the accepted tolerance values, the MASTER SWITCH will transfer the other loads over to the second power source (this happens instantly if the two sources are in phase).
PROTECTION AGAINST ENVIRONMENTAL DISTURBANCES Overloads and load faults In the event of an overload or fault condition, the internal protection system within the STS device can be configured to disconnect power at defined levels. In the extreme situation of a downstream short circuit MASTER SWITCH can disconnect the load to prevent disruption.
3P + N Source 2 Input
Input MCCB 1
Input MCCB 2
S2
S1
Maintenance Switch 2
Maintenance Switch 1
SS2
S4-2
SS1
S4-1
Output Switch 1
S3
Master Switch
CHARACTERISTICS • Full protection of critical industrial and IT applications against power failures and faults on the load. • Full microprocessor control which guarantees: - fast and safe transfer between the power sources. - monitoring of all parameters on the LCD display. - Constant control of the SCRs - Remote advanced diagnostics (RS232 and TCP/IP) • Redundant power circuits: - Power is supplied to the internal logic by two separate and independent power circuits that are hot swappable so as to ensure no break in the supply to the loads. - In the event that the power supplied by both sources fails, full system operation is guaranteed by the Power Supply Backup function that provides backup power to the circuits from an external, independent standby power source. • High protection - In the event of an output short circuit, MASTER SWITCH will block the transfer between the two power sources eliminating the risk of propagating the short circuit and its effects on the other loads. - A backfeed control circuit will trigger automatic protection devices to avoid energy feeding back to one of the inputs of the MASTER SWITCH. - MASTER SWITCH has double redundant ventilation called “fan redundancy plus”. Thanks to this function, in the remote possibility that two fans both fail at the same time, the others would still be able to dissipate the heat generated at nominal load. The fans can be hot swapped so as to ensure no break in system operation during the repair. • Easy front access - power cable connections are easily accessed with entry from below - board slots are positioned in a dedicated area to allow rapid diagnosis/replacement - all parts subject to controls, maintenance and/or replacement.
3P + N Source 1 Input
3P + N Output
Display
L1 L3
L5
L7 L4
L6
L8
L2
Dimensions (mm)
1770
MTS 200-X / MTS 250-X MTS 300-X / MTS 400-X
1500
MTS 100-X MTS 150-X
685
0
53
685
0
58
LED
FUNCTION
L1
S1 Priority source
L2
S2 Priority source
L3
S1 Present
L4
S2 Present
L5
Static switch SS1 closed
L6
Static switch SS2 closed
L7
Alarm indicator
L8
Output selection ON/OFF
5 function keys and LCD operations
61
UPS
UPS
MASTER SWITCH in [PS]
REDUNDANT Mode The reliable secondary source [AS] will power the load only and exclusively when the primary source (PS) fails, so as to guarantee maximum redundancy and quality of the power supply to the loads.
[AS]
USER 1
UPS
UPS
MASTER SWITCH in
[AS]
[PS]
CROSS FEEDING Mode The two sources power a number of critical loads using the MASTER SWITCHES configured in such a way as to make one of the two power sources the priority source (PS). In cases of power faults or failure on one of the two sources, the other one will be able to supply power to all the loads connected to the system.
USER 1 [AS]
[PS]
Master Switch
USER 2 Independent separate lines
UPS
MASTER SWITCH in
[AS]
[PS]
BACK UP Mode
MASTER SWITCH powers a number of loads using the priority source (PS). The secondary source (AS) is formed by independent and separate sources which can supply standby power should the priority source (PS) fail suddenly
USER 1 [AS]
[PS]
USER 2
Mains
Bypass 2
Mains
Mains
UPS1B
UPS2B
Battery
UPS2A
Battery
UPS1A
Battery
System B
Bypass 1
Mains
Battery
System A
UGS Sinchroniser
Static Transfer SWiTCH
Load 3 Load 1
Static Transfer SWiTCH
Load 4
62
Load 2
The solution offered RIELLO UPS guarantees La soluzione RIELLObyUPS garantisce la massimamaximum affidabilitàreliability e garanzia and ensures no break power in all operating thanks di continuità d’erogazione in supply qualsiasi situazione di conditions funzionamento tograzie the UGS option that the two systems A and Bi due perfectly all’opzione UGSkeeps che mantiene costantemente sistemi A & synchronised. B in perfetto sincronismo. The flexibility ofdelthesistema UGS system able guarantee that the power La flessibilità UGS è istale datogarantire il sincronismo fra sources remain synchronised when one ofnon thesia twoformato systemsda is not le sorgenti anche qualora unoeven dei due sistemi aUPS RIELLO UPSma model but made manufacturer when the RIELLO consista in UPSbydianother fabbricazione diversaoro sorgenti input sources not UPS’sa gruppi statici di continuità. d’energia nonare riconducibili
MODELS (1) NOMINAL CURRENT (A)
MTS 100-x
MTS 150-X
MTS 200-X
MTS 250-X
MTS 300-X
MTS 400-X
100
150
200
250
300
400
55
55
INPUT Nominal voltage - sources S1/S2
380 - 400 - 415 Vac 3-phases with neutral
Input voltage tolerance
180÷264 Vac (selectable)
Switched input phases
3+N (4-pole) - 3 (3-pole)
Nominal frequency
50/60 Hz
Input frequency tolerance
+/-10% (selectable)
Distribution compatibility
IT, TT, TNS, TNC
OPERATING FEATURES Transfer typology
“Break Before Make” (no sources overlapping)
Available transfer modes
Automatic / Manual / Remote < 4 msec (S1/S2 synchronised) 10 msec (S1/S2 not synchronised)
Transfer time for source failure ENVIRONMENTAL Efficiency at full load (%)
> 99
Noise level at 1 m from front (from 0 to full load) - (dBA)
52
55
Storage temperature range
-10°C to +50°C
Ambient temperature
0°C ÷ +40°C
Relative humidity
90% non-condensing 1000 m at rated power (-1% power for every 100 m above 1000 m) - Max 4000 m
Standard compatibility
Weight (kg) Colour Index of protection
Master Switch
Max. Installation height
Dimensions (h x w x d) (mm)
55
EN 62310-1 (safety) EN 62310-2 (electromagnetic compatibility) 1500 x 685 x 530 155
1770 x 685 x 580 175
205
210
220
240
Light grey RAL 7035 IP 20
(1) X= 3 in cases of 3-pole switching (3 phases) ; X=4 in cases of 4-pole switching (3 phases + Neutral)
63
Standby Power Systems
Standby Power Systems
Dialog CSS
• High-level diagnostics - preferably from a front mimic panel • Remote interface - normally volt-free contacts • High short circuit current capability
RIELLO UPS uninterruptible power supplies are also designed and built for use in applications such as central supply systems for emergency lighting, security alarms and electro-medical equipment. The CEI 64-8 V2, EN 50171 standards and other guidelines set down the characteristics and performance levels required from such systems. The main ones are summarised below:
The applications require a continuous power system configured as follows:
• Up to 3h back-up times • Battery recharge time of under 12h • Galvanically isolated input/output
• A standard UPS with high capacity battery charger • An isolation transformer option • A remote interface to communicate with other peripherals
Dialog CSS configurations MODEL
DIALOG PLUS
DIALOG DUAL
POWER DIALOG PLUS
MULTI DIALOG
1600 W
2000 W
3000 W
30,000 W
2100 W
3500 W
7000 W
64,000 W
Back-up times of up to 3 hours
POWER LOADS OF POWER UP TO Back-up times of up to 1 hour
POWER LOADS OF POWER UP TO
Characteristics
Options
• Full microprocessor control: for greater reliability and compactness in size • Use of Insulated Gate Bipolar Transistors (IGBT) technology - used in UPS for over 10 years to optimise performance (such as overloads) and reduce physical sizes • Advanced communication interface - the units come with a volt-free contact interface and RS232/485 serial interface for communication with a local PC or computer network • TeleNetGuard remote support service compatible for remote diagnostics and control • Front panel LCD to display operating status, alarms, measurements and logs • Option to expand the power and/or reliability through the parallel connection of units - 10kVA models and higher
• Communication interfaces: see accessories table for individual models • Isolation transformers
64
Advanced communication • Advanced, multi-platform communication for all operating systems and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems.
Compliance with Legislation The Dialog CSS range complies with the relevant European regulations (and national guidelines still in force in some countries) governing such applications.
A full range of CSS units, from 700VA to 200kVA The Dialog CSS range units are comprised of the following blocks: Rectifier: converts the alternating voltage input from the mains power supply or from an alternative source (generator) into direct current voltage. Inverter: converts the direct current voltage supplied by the rectifier into alternating voltage: in this way the voltage is reconstructed, filtered and stabilised with regard to the input voltage. By-pass: this allows switching between the inverter and the mains power supply. In “always powered” operating mode the CSS load is always powered from the inverter and is only switched onto the mains via the by-pass circuit in the event of a failure. In “powered from the mains” mode, the load is powered and only switched onto the inverter when there is no power from the mains. In “emergency only” mode the
load is only powered from the inverter in the event of a mains power failure. To deal with switch-on current surges, the inverter has a soft-start feature to limit the current supplied when required. In “always powered/ emergency only” two outputs can be used: one always powered (such as for powering computer loads) and one that is only powered when there is no power from the mains (such as for powering emergency lights that by law must switch on within a maximum time of 0.5 seconds from a mains failure). Batteries: used to feed the inverter output for the legally required time of 3 hours (if there is no generator). The batteries used are generally valve-regulated, lead-acid type, and do not require maintenance or a special installation room as they have very low gas emissions.
1. ALWAYS POWERED
2. POWERED FROM THE MAINS
3. emergenCY ONLY
Standby Power Systems
Diagrams of the various system solutions
4. ALWAYS POWERED/emergenCY ONLY
65
Telecommunication devices
Industrial PLCs
Industrial Processes
Electromedical Devices
Sinux Inverters
Sinux Inverters
Sinux is a range of 12/24/48/110 Vdc inverters with a 230 Vac 50Hz sinewave output. The output is galvanically isolated thanks to a built in transformer. The inverters are very efficient and have a wide input voltage window, that allows them to be used directly with photovoltaic (solar) panels.
S12 - S24 - S48 - SK1
Serial port Input protection Input/Output connections
TECHNICAL DETAILS 66
CHARACTERISTICS • Standard galvanic isolation: the system has a built in transformer to ensure galvanic isolation. • Wide input voltage range: the inverters have a wide input range and are compatible with photovoltaic systems and do not require extra regulation hardware • Full diagnostics: the inverters provide both visual and audible status and diagnostic information • Built-in protection. Protection includes: over and under voltage, reverse polarity, overloads, short circuits and over temperature • Automatic restart: the inverters auto restart when the alarm condition is resolved • Optional bypass • Optional LCD display • Dry contacts interface board: - standard: dc voltage present; dc voltage low - optional: overload; inverter fault; overtemperature • Special versions available on request • Compatible options available on request
MODELS
POWER (W)
INPUT Rated voltage
OUTPUT Voltage range
ENVIRONMENTAL
Output current (A)
Overload (W) for 5”
Weight (kg)
Dimensions (HxWxD) (mm)
AVAILABLE OPTIONS By-pass
LCD Display
Remote contacts
•
•
•
•
SINUX INVERTERS S12 (12 Vdc input) S12 120
115
0.5
300
13
S12 160
161
0.7
400
15
S12 350
345
1.5
600
30
•
•
S12 460
460
2
800
32
•
•
S12 580
575
2.5
1000
35
•
•
S12 690
690
3
1200
40
•
•
S12 800 805 SINUX INVERTERS S24 (24 Vdc input)
3.5
1400
45
•
•
S24 030
30
0.13
50
3
S24 230
230
1
600
13
•
•
•
S24 320
322
1.4
800
15
•
•
•
S24 530
529
2.3
1000
19
•
•
•
S24 780
782
3.4
1200
30
•
•
•
S24 920
920
4
1600
32
•
•
•
S24 1K1
1150
5
2000
35
•
•
•
1380
6
2500
40
•
•
•
1610
7
2800
45
•
•
•
1840
8
3000
52
•
•
•
2760
12
4000
60
•
•
3680
16
5000
72
•
•
18
6000
80
•
•
S24 1K6 S24 1K8 S24 2K7 S24 3K6
24 V
10.2 - 18 V
19 - 43 V
S24 4K1 4140 SINUX INVERTERS S48 (48 Vdc input)
4U x 19” x 510 5U x 19” x 510
2U x 19” x 160
4U x 19” x 410
4U x 19” x 510
5U x 19” x 510
5U x 19” x 710
30
0.13
50
3
100
0.45
130
3.5
S48 150
150
0.65
230
4
S48 320
322
1.4
800
13
•
•
•
1000
15
•
•
•
S48 030 S48 100
39 - 60 V
2U x 19” x 160
S48 460
460
2
S48 690
690
3
1200
19
•
•
•
S48 920
920
4
1500
30
•
•
•
S48 1K1
1150
5
2000
32
•
•
•
S48 1K4
1380
6
2500
35
•
•
•
S48 1K7
1725
7.5
3500
40
•
•
•
S48 2K0
2070
9
4000
45
•
•
•
S48 2K5
2530
11
4500
52
•
•
•
S48 3K4
3450
15
6000
60
•
S48 4K1
4140
18
7000
66
•
•
S48 5K0
5060
22
8000
72
•
•
S48 6K2
6210
48 V
39 - 80 V
S48 6K9 6900 SINUX INVERTERS SK1 (110 Vdc input)
39 - 60 V
4U x 19” x 410
4U x 19” x 510
5U x 19 ”x 510
5U x 19” x 710
•
27
9000
78
•
•
30
10000
83
•
•
SK1 030
30
0.13
50
3,5
SK1 100
104
0.45
130
4
SK1 150
150
0.65
180
4
SK1 320
322
1.4
800
13
•
•
•
SK1 460
460
2
1000
15
•
•
•
SK1 690
690
3
1200
19
•
•
•
SK1 920
920
4
1500
30
•
•
•
SK1 1K1
1150
5
2000
SK1 1K4
1380
• •
• •
1825
2500 3500
• •
SK1 1K7
6 7.5
32 35 40
•
•
•
SK1 2K0
2070
9
4000
45
•
•
•
SK1 2K5
2530
11
4500
50
•
•
•
SK1 2K8
2875
12.5
5000
55
•
•
•
SK1 3K5
3450
15
6000
60
•
•
SK1 4K1
4140
18
7000
66
•
•
SK1 5K0
5060
22
8000
72
•
•
SK1 6K2
6210
27
9000
78
•
•
SK1 6K9
6900
30
10000
83
•
•
110 V
88 - 145 V
Sinux Inverters
S24 1K4
12 V
4U x 19” x 410
2U x 19” x 160
4Ux 19” x 410
4U x 19” x 510
5U x 19” x 510
5U x 19” x 710
Product characteristics can be customised to meet client specifications.
67
Software and Accessories
Connectivity
68
Powershield3
Communication Software PowerShield3 provides efficient, user-friendly UPS management using bar chart displays to show major operational information such as the input voltage, UPS load % and batteries charge %. The software also provides detailed information on fault conditions and UPS operating characteristics. PowerShield3 has been developed with a client/server architecture that makes it flexible and easy to use, and provides multi-lingual and on-line support.
PowerShield3 can be downloaded free of charge from www.riello-ups.com
All the trademarks indicated are the property of their respective owners.
Software and Accessories
GRAPHIC MONITORING OF UPS AND Environmental Sensors STATUS PowerShield3 is a simple but powerful RIELLO UPS management tool. There are various graphic versions for all the operating systems. DETAILED UPS PARAMETER DISPLAY AND Environmental Sensors PowerShield3 provides all the information required for first level diagnostics. EVENTS LOG AND GRAPHICAL DISPLAY All changes in UPS operating status are logged and displayed in a graphical format from which the user can monitor trends in the mains electrical parameters monitored. PROGRAMMING OF UPS PARAMETERS The user can select several options remotely: turn the UPS on or off, restart after a power loss and instigate a battery test. GRAPHIC MONITORING OF UPS STATUS VERSION FOR MAC OS X RIELLO UPS PowerShield3 software is the only UPS control and shut-down software running under Macintosh with a client-server cross platform architecture. It allows integration in TCP/IP networks with Windows, Novell, IBM OS/2 and the most widely used UNIX operating systems. PowerShield3 supports the Netman Plus series of network agents and provides multi-language support. BLOCK AND FUNCTIONAL DIAGRAMS PowerShield3 also displays the UPS in block format providing the user with information regarding operating status. NOTIFICATION OF ALARMS VIA E-MAIL, SMS, FAX AND VOICE PowerShield3 can be configured to forward alarm messages automatically via e-mail, SMS, fax and voice.
Characteristics • Sequential and priority-based shutdown: PowerShield3 provides unattended shutdown of single and networked PCs, saving any active work and the most widely used applications Windows. Users can define their own shutdown procedures and establish the order in which critical computers (such as servers) are to be powered down • Multi-platform compatibility: PowerShield3 uses the TCP/IP communications protocol to achieve standardised management and monitoring across the widest possible range of platforms. This makes it possible to monitor computers with different operating systems from a single console, for example monitoring a UNIX server from a PC with Windows and also connecting to UPS located in different geographical areas using dedicated networks (intranets) or the Internet • Event scheduling: PowerShield3 users can program their own shutdown procedures, detailing power-off and power-up scenarios to increase system safety and, equally important, power economy • Messages management: PowerShield3 keeps users constantly informed about the status of their local and network UPS, and environmental sensors. A list can be defined of users who should receive e-mail messages, faxes and SMS when faults or sudden mains power supply failures occur • Integrated SNMP agent: PowerShield3 features an integrated SNMP agent for UPS management which can send all the information required and generate traps using the RFC 1628 MIB standard and environmental sensors. This
feature makes it possilbe to manage the UPS in compatible SNMP management stations such as HP Open View, Novell Managewise and IBM NetView • Wap server integrated: PowerShield3 allows the user to monitor a UPS through WAP mobile phone • Security, easy to use and connect, communication is password protected to ensure UPS system security. Using the new discovery/browsing function, all the RIELLO UPS connected to a protected computer or LAN can be displayed in a list format. In the absence of a LAN connection, support is provided for modembased communication.
Operating systems supported • Windows 98, Me, NT 4.0, 2000, 2003, XP, Vista, 2008 Server on processors X86, X86_64 e IA64 • Linux on processors X86, X86_64 e IA64 • Novell Netware 3.x, 4.x, 5.x, 6 • Mac OS X • The most widely used UNIX operating systems such as: IBM AIX, HP, SUN Solaris INTEL and SPARC, SCO Unixware and Open Server, Silicon Graphics IRIX, Compaq Tru64 UNIX and DEC UNIX, Open BSD UNIX and FreeBSD UNIX, NCR UNIX • HP OPEN VMS 69
PowerNETGuard
Software and Accessories
Supervision software
PowerNETGuard software centralises UPS management using network interface (SNMP) communications. It is ideal for Data Centre managers and medium to large sized networks. PowerNETGuard uses the RFC1628 standard Management Information Base (MIB) and ensures standardised UPS management wherever they are located.
Characteristics • Centralised control of remote UPS via Ethernet with SNMP protocol • Multiple-level display of geographical areas, building plans, maps, etc. • Multi-user access with various levels of security • Compatible with Netman Plus and RFC1628 standard network interface (SNMP) • Graphs of physical input and output values stored and backed up to file • Alarm notification via e-mail and SMS • Wap Server • Operating systems supported: Windows (98, ME, NT, 2000, 2003, XP and Vista), Linux, MacOSX, Solaris 8, 9 and 10 and Silicon Graphics IRIX
Centralised control of remote UPS 1. 1.
1. 2.
1. NETMAN PLUS CONNECTION 2. THIRD PART SNMP AGENT 70
Network agent
NetMan 101/102 Plus The NetMan Plus network agent allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface (SNMP). NetMan Plus enabled UPS integrate easily into medium and large sized networks and provide reliable communications between the UPS and management systems employed.
• Configured via TELNET or a serial terminal • Compatible with PowerShield3 and PowerNETGuard control software • Supports the network interface (SNMP) standard communication protocol with proprietary RFC 1628 and MIB
• SNMP with RFC 3433 to manage the environmental sensors • Integrated Web server for browser-based display • TeleNetGuard modem compatible • Firmware upgradeable through the serial port • E-mail sent through SMTP server
Software and Accessories
Characteristics
Environmental Sensors The Netman environmental sensors monitor and record environmental conditions as well as activities in protected areas and at the premises where the UPS is installed. Environmental sensors monitor and record environmental conditions and activities within a designated building area. The sensors provide extensive management and control, triggering cooling fans and locks in response to changes in temperature and humidity. Remote monitoring and control can be provided via the internet, SNMP and the Riello PowerShield³ software. NetMan Plus can support up to 6 separate sensors. The environmental sensors are easy to install and do not need a separate external power supply. The following sensors are available: - Sensor for temperature: -55 +125 °C - Sensor for temperature: -55 +125 °C and humidity: 0- 100% - Sensor for temperature: -55 +125 °C and digital I/O: 0-12Vdc. In, 1A max Out 48Vdc
APPLICATION DIAGRAM
Air conditioner
APPLICATION DIAGRAM Temperature sensor
Smoke detector
Temperature sensor Temperature sensor
71
Protocol Converter
Multicom 301/302 The MultiCOM 301/302 protocol converter may be used to monitor the UPS using the MODBUS/JBUS protocol on RS232 or RS485 serial lines. It can also manage a second independent RS232 serial line that can be used to connect to other devices such as the Netman 101 or a PC using PowerShield3 software.
Characteristics • Port configuration for MODBUS/JBUS as RS232 or RS485 • Management of two independent serial lines • Suitable for Building Management System (BMS) integration
• LED communication flow indicators • Firmware upgradeable through the serial port
Serial link duplexer
Multicom 351/352 The MultiCOM 351/352 is a serial duplexer that allows two devices to be connected to a single serial port on a UPS. It can be used where numerous serial connections and multiple UPS polling are required, and is ideal for LAN networks with a firewall.
Characteristics • Cascading configuration giving a maximum of 4 serial communication ports • LED communication flow indicators • Firmware upgradeable through the serial port.
Serial / USB port
Multicom 362
MultiCOM 362 provides a UPS with an additional RS232 serial interface or USB port. The USB port allows the UPS to communicate with Apple Macintosh computers as well as Windows and Linux operating systems.
Characteristics • Compatible with USB 1 or 2 • Compatible with PowerShield3
72
Serial / EPO port
Multicom 372 MultiCOM 372 provides a UPS with an additional RS232 serial interface port. The card has Emergency Power Off (EPO) and Remote Shut Down (RSD) inputs with terminal connections.
Characteristics
Software and Accessories
• EPO and UPS shutdown interface • 12Vdc 80mA contact option
Contacts / EPO board
Multicom 382 MultiCOM 382 provides a set of relay contacts to provide UPS alarm and status indication. The contacts are connected through terminal connections. Signal contacts include Emergency Power Off (EPO), Remote Shut Down (RSD), On Battery, On Bypass, Alarm and Low battery. The contacts are change over or normally open.
Characteristics • Max. 3A current at 250Vac • Signal contact customisation
Protocol converter
Multi I/O
Multi I/O has configurable input and output signal contacts to allow UPS integration with control systems. It can be used to connect two devices to a single UPS serial communication port. It can also communicate using the MODBUS/JBUS protocol on RS485 lines.
Characteristics • 8 analog/digital inputs • 8 relay outputs to monitor UPS and mains status • It can control two independent RS232/RS485 serial lines to monitor the UPS and its operating states using the MODBUS/JBUS protocol • Firmware upgradeable through the serial port 73
USB serial converter
USB Converter The RS232-USB converter allows UPS without a USB port to connect to Macintosh, Windows and Linux PCs with this type of port.
Characteristics • Compatible with USB 1 or 2 • Compatible with PowerShield3
Serial link / contacts duplexer
Multifunction I/O Multifunction I/O is a Dialog plus range accessory through which you can monitor battery operation, by-pass, alarm and battery discharged status reports with dry contacts (maximum current 8A/250V). The accessory also has an input which is used to set up the configurable remote on, remote off and remote on/off functions through the UPSTools software (vers. 1.3.3 or higher). These functions are provided for UPS with firmware version SWM020-01-16 or higher.
Characteristics • Max. current 8A at 250Vac • Possibility of configuring the signal-to-contact associations • Pass-through serial link for PC connection
Protocol converter
Multicom 401
The Multicom 401 is an accessory with which you can connect a UPS to a Profibus DP network. With this device management and monitoring of the UPS can be integrated in a control system based on one of the field buses most widely used in industry for communication between control/automation systems and distributed I/O.
Characteristics • PROFIBUS DP-V1 Protocol • Configurable address from 0 to 99
74
• Profidrive V2 PP05 • Configurable baud rate from 9.6 kBit/s to 12 MBit/s • Led reporting the communication flow
Communication Kit
Kit AS400 / i-Series
The IBM AS/400 has a single-level memory management feature that makes it compulsory for the system to be shutdown in a controlled and orderly manner. Without UPS protection an AS/400 is not protected from mains failures. A momentary loss of power can cause hardware damage, data corruption and a lengthy reboot period. The RIELLO UPS AS/400 interface kit allows a UPS to be connected to the AS/400 to initiate an orderly system shutdown on mains failure.
Characteristics • Compatible with all AS/400 systems • Supports all the RIELLO UPS ranges
Remote Monitoring Panel
Multi Panel
MultiPanel is a remote monitoring device that can provide a detailed UPS status overview in real time. It is compatible with all Riello UPS and can display values for UPS specific input and output supplies, and battery set measurements. MultiPanel has a high-definition graphical display and can report in 7 languages: English, Italian, German, French, Spanish, Russian and Chinese. It has 3 independent serial ports, one of which allows for UPS monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The others can be used with devices such as the Netman 101 Plus or a PC running PowerShield3 software.
Characteristics • Graphical high definition LCD panel • Three independent serial connections
• Compatible with most BMS management programs • Communications flow LED status indicator • Serial port upgradeable firmware
75
Compatibility table
1
•
•
•
•
•
•
•
•
•
•
Multipanel
PowerNetGuard
NET DIALOG
Telenet Guard
AS/400 Kit
•
Multi I/O
•
MultiCOM 382
•
MultiCOM 372
•
MultiCOM 362
•
MultiCOM 302
•
MultiCOM 301
•
MultiCOM 352
•
MultiCOM 351
•
1
PowerShield3
•
SLOT
1
PLUG DIALOG
RS232 port
MultiCOM 401
Multifunction I/O
NetMan 102 plus
NetMan 101 plus
Microsoft Plug & Play
UPS Modem Management
Software and optional accessories
WIN DIALOG PLUS
USB Port
Software and Accessories
Standard fittings
•
IDIALOG IDIALOG PLUS
DIALOG VISION
1
1
DIALOG PLUS DIALOG PLUS RACK
•
1
1
•
•
•
•
•
•
•
•
1
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
•
•
•
•
•
•
•
•
•
•
•
DIALOG DUAL
1
1
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
POWER DIALOG 3
1
1
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
2
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
MULTI DIALOG MULTI PLUS
1
3
•
•
•
•
•
•
•
•
MASTER PLUS / HIP
2
2
•
•
•
•
•
•
•
•
MASTER DIALOG
1
•
•
•
76
1
•
•
•
•
•
•
Maintenance Bypass
MBB10A - MBB16A MBB32A This is available in 10, 16 and 32 Amp models, and allows a UPS unit up to 6kVA to be safely powered down for maintenance/removal, without any disruption in the power supplied to the load. Both versions are supplied with a wall mount metal bracket.
MAINS LOAD OUT UPS
By-pass Accessories
Multi PASS 16 Wall mount version Rear panel Multi PASS 16-R Rackmount version
Manual Bypass
Multi Pass 16 / 16-R Multi PASS is a maintenance bypass to allow a UPS to be powered down and removed for service without disruption to the connected load(s). Multi PASS has both manual and automatic transfer functions. If the UPS is accidentally disconnected or fails any load(s) connected to Multi PASS are automatically transfered to the mains supply. Multi PASS is available in wall mounted or 19” rackmount formats. RIELLO UPS supplies a wide range of external maintenance bypasses and switchgear for their UPS up to the 800kVA Master Plus and for parallel systems up to 6.4MVA.
Characteristics • Wall or rackmount versions • Back-feed protection
• Manual and automatic transfer functions • Mains power present LED indicator • IEC, UK, Schuko and hard wired connected options
Maintenance Bypass
MBB100A
Available only in one version which allows manual bypass operations on any 10 to 20kVA single phase UPS and 10 to 40kVA three phase UPS. The device comes with three circuit breakers as shown in the attached diagram, so as to ensure complete isolation of the UPS during maintenance or removal operations, whilst guaranteeing continuous power supply to the loads. The device has a microswitch for connection to the appropriate UPS input, which signals closure of the manual bypass, in order to prevent energy being supplied simultaneously from the manual bypass and the inverter. RIELLO UPS offers a wide range of external bypasses and static switches for UPS models up to 800kVA and for parallel systems up to 6.4MVA.
SWIN
MAINS
TO UPS INPUT or UPS BYPASS INPUT
AUX REMOTE MAINTENANCE bypass (normal close contact)
SWMB AUX
LOAD
SWOUT
FROM UPS BYPASS
77
Services and consultancy
Pre-sales consultancy TEC is the RIELLO UPS pre-sales advisory service. Our TEC (Technical Energy Consultant) experts have been working in the power sector for years, and come from backgrounds with technical experience in industry and power plants. CONSULTANCY ON STANDARDS TEC personnel can provide advice on the relevant standards affecting: • RIELLO UPS product ranges • Batteries • Installation • Applications - such as emergency lighting, security and electro-medical WORK TOOLS TEC training and information is provided in the form of: • UPS sizing • Official technical guides • Installation and specification manuals • TEC newsletters • Technical specifications TECHNICAL CONSULTANCY TEC personnel can provide advise and guidance on the selection, sizing and installation of RIELLO UPS products. SUPPORT IN DESIGN TEC personnel can provide assistance in the design of a UPS system to completely satisfy customer specifications, including bespoke designs. HELP DESK TEC is available 24-7 around the world and may be reached by phone, fax or e-mail to answer your requests immediately.
Technical support and services UPService, our technical assistance facility uses highly trained engineers to provide a reliable and competent technical support and after-sales service. UPService can provide customers with: • A dedicated CALL CENTRE for connection to the UPService organisation. UPService personnel are always available and ready to provide advice and assistance regarding UPS installation, maintenance, fault finding and repair. • The free SWAP assistance service. • ON SITE a site based service for larger UPS that cannot be transported back to the UPService facility, either inside or outside warranty. A fast repair on site is guaranteed through the use of state-of-the-art UPS technology and the professionalism of the UPService personnel and Authorised Assistance Centres. UPService guarantees that failed parts are replaced with functioning ones, tested and updated in order to maintain the safety, reliability and operating characteristics of the UPS. • On request, UPService can provide assistance during installation and initial startup of the UPS and train on-site personnel. UPService engineers can also verify site suitability, analyse and advise on rental solutions and disconnect and relocate equipment. • MAINTENANCE CONTRACTS can be provided by UPService to minimise response times and repair costs. Contracts range from periodic inspections to comprehensive cover including labour and materials. • The TeleNetGuard software package provides remote 24-7 UPS supervision. TeleNetGuard can interrogate RIELLO UPS connected to a local telephone line to check on their operating logs and system status. Should the UPS report an alarm condition, the UPService Call Centre is immediately notified and a dedicated customer response activated. Routine site reports can be sent automatically to customer personnel.
UPService organises regular TECHNICAL TRAINING COURSES for UPS operators and installers.
tec@riello-ups.com 78
r.service@riello-ups.com
Operating Offices UK RIELLO UPS Ltd Unit 68 - Clywedog Road North Wrexham Industrial Estate - Wrexham LL13 9XN Tel.: +44 (0)1978 729 297 - Fax: +44 (0)1978 729 290 www.riello-ups.co.uk / riello@riello-ups.co.uk ITALY LEGNAGO, Head Office
Viale Europa, 7 ZAI 37045 Legnago Verona - ITALY Tel.: +39 0442 635811 Fax: +39 0442 629098 www.riello-ups.com riello@riello-ups.com MILANO Via Somalia, 20 20032 Cormano (MI) Tel.: +39 02 61541711 Fax: +39 02 61541750 www.riello-ups.com riello@riello-ups.com
CONSTANT POWER SERVICES Ltd Unit 3 - Trust Industrial Estate, Wilbury Way Hitchin, Herts, SG4 0UZ Tel.: +44 (0)1462 422 955 - Fax: +44 (0)1462 422 754 www.cps4ups.co.uk / info@cps4ups.co.uk FRANCE RIELLO ONDULEURS s.a.r.l. Direction, 6 Rue de la Mare Neuve Actipark, Bois Briard 91080 Courcouronnes Tel.: +33 (0)1 60 875454 - Fax: +33 (0)1 60 875450 www.riello-onduleurs.com - ventes@riello-onduleurs.com VENTES SUD Siège, Parc d’Activité de Limonest, Bâtiment 2 – Hall A Rue des Vergers 69760 Limonest Tel.: +33 (0)4 72 177108 - Fax: +33 (0)4 78 351422 www.riello-onduleurs.com - contact@riello-onduleurs.com ESPAÑA RIELLO ENERDATA s.l. P.I. Prado del Espino C/Labradores 13 28660 Boadilla del Monte, Madrid Tel.: +34 (0)91 63 33 000 - Fax: +34 (0)91 63 21 793 www.enerdata.es / enerdata@enerdata.es RIELLO TDL s.l. c/ Terra Alta, 88 - P.I. “Can Carner” 08211 Castellar Del Vallès, Barcelona Tel.: +34 (0)93 74 71 210 - Fax: +34 (0)93 71 46 562 www.riello-tdl.com / comercial@riello-tdl.com RIELLO UPS - HELIOS POWER C/ Pintor Sorolla, 19 - 7a 13a 46002 Valencia ESPANA Tel. +34 963 52 52 12 - Fax +34 963 52 46 99 www.riello-ups.com/heliospower - heliospower@riello-ups.com DEUTSCHLAND RIELLO UPS GmbH Siemensstr. 12 21465 Reinbek Bei Hamburg Tel.: +49 (0)40 727 57-06 - Fax: +49 (0)40 727 57-189 www.riello-ups.de / info@riello-ups.de CHINA Riello UPS (Asia) Co., Ltd 28F, No. 500 Fute Dong Er Road, Waigaoqiao Free Trade Zone 200131 Shanghai, PEOLPLE’S REPUBLIC OF CHINA Tel: +86-21-50464748 - Fax: +86-21-50464648 www.riello-ups.com - sales@rielloups.cn ASIA PACIFIC RPS RepRESENTATIVE Office No.9, Shenton Way #04-08 068813 Singapore www.riello-ups.com - info@riello-ups.sg
79
official sponsor Ducati Corse
CATGENX0109RUGB
In the interests of product improvement Riello UPS reserves the right to change specifications without notice.
General Catalogue 01. 2009