Green architecture portfolio

Page 1

rizkit_siregar green research portfolio


Analysis Software

Research History

Autodesk Ecotect

Autodesk Vasary

Autodesk Green Building Studio JMP 7 CFD floVENT Assistant of Building Technology

Research Group. Institut Teknologi Bandung

Bandung Creative City Forum (BCCF)

Rizki Tridamayanti Siregar June, 26th 1987 Female Indonesian +62 - 0857 2156 3121 siregar.rizkit@gmail.com

Education History

Academic Assistant - ITB

2005 – 2009

Bachelor of Architecture – Indonesia University of Education, Indonesia

Istana Negara (Jakarta)

2010 – 2013

Gelora Bung Karno Stadium (Jakarta)

Graduate Program of Architecture – Institut Teknologi Bandung (ITB)

Istora Senayan (Jakarta)

PT. Dhika Architama & IFC World Bank

Istana Merdeka (Jakarta)

Bandung Green Building Regulation (Bandung)

Recognition

RKONS Bagusrangin Apartment (Bandung)

Master Course Scholarship - Institut Teknologi Bandung, Indonesia

Thesis Research Grant - Institut Teknologi Bandung, Indonesia Thesis Title :

Bahasa Indonesia / Mother Tongue English / Oral and Written

Architect – PT. LAPI ITB

The Influences Of Building Material To Indoor Thermal Environment Case Study : Cigugur Public Housing, Indonesia


CONTENT

CIGUGUR PUBLIC HOUSING cigugur public housing PARAHYANGAN APARTMENT Merdeka and negara Palace Gelora bung karno stadium Bagusrangin apartment

An Adaptive Double Skin Facade Year Type Location

: 2013 : Public Housing : Cimahi, West Java

Four stories apartment building, Located at Cimahi City, West Java. The occupants have been complaining about uncomfortable temperature in their flats. The researcher try to fix this problem with material study approaching and aplicated lightweight secondary skin. Some laboratory test and environment simulations have been done to endorse the research result.


SI TE

S OLAR AN D SH A D OW A N A LY S IS 4 stories of apartment building, located at Cimahi West Java 1070 34�30�E and 060560000S. Orientation 220 north offset.

The comparison of indoor temperature from all orientations shows that northeast and southwest orientation have the highest temperature of them all. 09.00 AM

11.00 AM

01.00 PM

3.00 PM

05.00 PM

MAT E RI A L AN A LY S I S The percentage of direct solar gain on northeast and southwest wall.

An experiment was conducted between 6 building models that have different wall material (heavyweight concrete and lightweight concrete) on each orientations. The aim is to show the potential reduction of indoor temperature based on its orientation and material characteristics. Model 4 (lightweight concrete on northeast wall and h eavyweight concrete on southwest wall) comes with the best result, it reduces the air temperature 0.360C - 10C .

08 am

09 am

10 am

11 am

12 am

12 am

01 pm

02 pm

03 pm

05 pm


DO UB LE S KI N FA C A D E C O NCEPT

Direct solar and wind sirculation on double skin facade 11 AM

PARAHYANGAN APARTMENT Year Type Location

10 AM

wind sirculation

: 2014 : Public Building : Bandung, Indonesia

14 Stories apartment building was designed to combat the increasing pressure for climate change. The orientation and shape of the building represent an optimised shape according to the local microclimate.

U

08 AM

Site Direct solar “pattern� on external wall

The lowest temperature Medium temperature The highest temperature

The main concept of double skin facade comes from the building plan.

1

2

3

4

5

6

Mass Concept

Maximizing the view

Solar

& shadow study


PROFESSIONAL

ENE RG Y ANALYS I S

PROJECTS

25 0C - 27 0C Ideal indoor temperature (SNI 8390 : 2011)

VS 19 0C - 21 0C Actual indoor temperature in tthese wo palace. (Air Conditioner)

To reduce HVAC energy consumption, passive design strategi is needed.

Merdeka and negara Palace De s ig n a n d E n e rg y A s s e s s me n t Year Type Client Location

: : : :

2014 Government Building Sekretaris Negara RI Jakarta, Indonesia

As the symbol of the government of Republik Indonesia, the client want to make this building as an excellent example of a green building in Indonesia. Therefore, the preliminary study is needed to find the best model solution. Some research and design approach have been done, from observation, field study, and laboratory simulation, just to find the greenest building model that can achieve.


W I ND AND E NE RGY C O MPARIS O N

MOD E L C O M PA R I S O N

Building plan comparison between the building design proposal and building existing. Building plan comparison between the building design proposal and building existing.

N ega ra Pa la ce

Merdeka Palace

B e fo re

B e fo re

Af ter

Before

A ft e r

Af ter

The design proposal is better than existing building. The quality of air circulation increase by 42.35%. It makes the potential of energy consumption decrease by 40%.


GELORA BUNG KARNO STADIUM Year Type Client Location

: : : :

2014 Stadium Sekretaris Negara RI Jakarta, Indonesia

Gelora Bung Karno (GBK) is one of the largest in the world since 1962, the stadium could initially seat up to 100.000 people. The latest renovation was done in 2007 for ASIAN Cup purpose. The next 2018 ASEAN GAMES will be held in Indonesia and GBK will be the main stadium, therefore a building assessment is needed to get Indonesian Certificate of Building Profer Function / Sertifikat Laik Fungsi (SLF).

GBK safety analysis

“The Good guy GBK� is trying to reach SLF for ASEAN GAMES 2015....

U need to check my Safety..

My Green Building Aspect ..

My performance..

My Comfort..

The red circles indicate safety zones (according to Indonesian Certificate of Building Profer Function, each zone at least 20m from emergency exit). There are many zone that not comply with applicable regulation.

Solar radiation analysis


west west

BAGUSRANGIN APARTMENT

East Year Type Location Solar radiation

West-facing side receive more solar radiation than other side, although the difference is not significant.

: 2014 : Public Housing : Bandung, Indonesia

Perjuangan Monument

The ambition to make Bandung more livable city is the basis of this program. This project provides low cost apartment for the poor so there are no slum areas. Site Allocation Residence Commercial

Gedung Sate

Wind and airflow analysis

PT. Telkom


APART ME NT INT E RLO C K ING

U

Shadow range and solar analysis Cul-de-Sac 4 Unit

Apartment Shopping Corridor & Hotel Parking Building & Public Facilities

Airflow between buildings block

Landscape

Airflow in urban landscape Cul-de-Sac 6 Unit


To be continued..