ROHN 25G Tower

Page 1


G

GUYED TOWERS - 25G

S TA N D A R D 2 5 G G U Y E D T O W E R

ROHN 25G The first. The original.

includes

REV. F & REV. G

25G

GENERAL USE The 25G is available in the standard 10’ section length and a 7’ length which is UPS shippable. The 25G uses double bolted joints, proven to be the best method of joining tower sections for sturdiness and dependability. As a guyed structure, the 25G standard designs rise to a height of 190’.

FEATURES • Completely hot-dip galvanized after fabrication • Built on an 11 1/4” equilateral triangle design • High strength tubular legs joined by Zig-Zag®

cross members • Each 7’ or 10’ section contains all required nuts and bolts shipped with section • Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 40 for ordering information.

24

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D 2 5 G G U Y E D T O W E R SECTIONS 6 1/2” 9 3/4”

QUICK REFERENCE PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION

11 1/4”

1’ 6”

Optional Waveguide Brackets (KY2041A)

PAGES 37-40 PAGE 41 PAGES 41-44 2.25” O.D. 2.08” I.D. (14 GA.)

1’ 3” 9’ 9” 1 1/4” O.D. (16 GA.)

1 1/4” O.D. (16 GA.)

~ ~

5/16” O.D. Solid Bracing

Optional double braced sections are available upon request.

5/16” O.D. Solid Bracing

STANDARD TOP SECTION 25AG2 Additional 25G top sections are shown on page 37.

CONCRETE BASE PLATE BPC25G*

STANDARD SECTION 25G - 10’ Section

FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE.

OPTIONAL 7’ SECTION 25G7 - 7‘ Section

Additional base sections are available, please see page 38.

The 7’ Section is UPS shippable. * Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

25


G

GUYED TOWERS - 25G

BUYERS GUIDE S TA N D A R D D E S I G N S - 2 5 G 9 0 M P H R E V. G [ 3 - S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 16.6

22.6

35’

EPA (SQ. FT.) For Exposure C, Revision G

22.0 47’ 3/16” EHS (399#)

EPA (SQ. FT.), Revision F Guy Initial Tension

P/N 25G90R040 32’

P/N 25G90R040

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 25G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 41-44. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

26

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 35’

40’ TOWER 22.6 OR 16.6 22.0 47’ 3/16” EHS (399#)

32’

P/N: 25G90R040

45’

50’ TOWER 21.4 OR 15.8 21.0 60’ 3/16” EHS (399#)

23’

46’

40’

P/N: 25G90R050

55’

60’ TOWER 20.3 OR 15.2 20.2 73’ 3/16” EHS (399#)

28’

56’

48’

P/N: 25G90R060

65’

70’ TOWER 19.4 OR 14.7 19.4 86’ 3/16” EHS (399#)

32’

64’

56’

P/N: 25G90R070

75’

80’ TOWER 18.6 OR 14.3 18.8 99’ 3/16” EHS (399#)

50’ 81’ 25’

69’ 64’

P/N: 25G90R080

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

25G

25AG2

3

1

3/16EHS

BG2142

175’

6

BPC25G GA25GD 1

1

FDNS

BASE ANCHOR

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 6

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3 3/4x12PP

3

1

3

3

1

25G

25AG2

BPC25G

GA25GD

BASE ANCHOR

4

1

1

2

3/16EHS

BG2142

350’

12

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

5

1

1

3/16EHS

BG2142

425’

12

3

3

12

1

3

25G

25AG2

BPC25G

6

1

1

3/16EHS

BG2142

500’

12

1

2

CB1G AB2

6

3

3 3/4x12PP

FDNS GA25GD BASE ANCHOR 2

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

7

1

1

3/16EHS

BG2142

800’

18

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

80’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 080

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

70’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 070

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 18

60’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 060

1

5/16THH 1/2TBE&J TBSAFETY 12

50’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 050

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

1

CB1G AB2

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

FDNS

5/16THH 1/2TBE&J TBSAFETY 12

40’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 040

27


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 90’ TOWER 18.0 OR 13.9

85’

18.4 111’ 3/16” EHS (399#)

57’ 92’ 28’

77’ 72’

P/N: 25G90R090 100’ TOWER 17.5 OR 13.6

95’

18.0 124’ 3/16” EHS (399#)

63’ 102’ 31’

86’ 80’

P/N: 25G90R100

110’ TOWER 17.0 OR 13.4

105’

17.6 137’ 3/16” EHS (399#)

70’ 112’ 35’

95’ 88’

P/N: 25G90R110 120’ TOWER 16.6 OR 13.1

115’

17.2 150’

85’

128’ 55’

3/16” EHS (399#)

111’ 100’

28’

96’

P/N: 25G90R120

125’ 93’

130’ TOWER 16.2 OR 12.9 17.0 163’ 140’

62’ 31’

3/16” EHS (399#)

121’ 108’ 104’

P/N: 25G90R130

28

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

25G

25AG2

BPC25G

8

1

1

3/16EHS

BG2142

900’

18

GA25GD BASEFDNS ANCHOR 3

5/16THH 1/2TBE&J TBSAFETY 18

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

9

1

1

3/16EHS

BG2142

1000’

18

3

3/4x12PP 1

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

1

3

25G

25AG2

BPC25G

10

1

1

3/16EHS

BG2142

1100’

18

9

3

3 3/4x12PP 1

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

1

3

25G

25AG2

BPC25G

11

1

1

3/16EHS

BG2142

1575’

24

9

3

3

1

FDNS GA25GD BASE ANCHOR 4

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

12

1

1

3/16EHS

BG2142

1700’

24

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 4

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

120’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 120

3/4x12PP

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 24

110’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 110

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 24

100’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 2590R 100

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

1

3

90’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 090

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

CB1G AB2

3

3

130’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 130

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 140’ TOWER 15.9 OR 12.7

135’

16.6 175’

99’

149’ 66’

3/16” EHS (399#)

130’ 117’

33’

112’

P/N: 25G90R140 150’ TOWER 15.5 OR 12.5

145’

16.4

116’

188’

87’

167’ 148’

58’

3/16” EHS (399#)

133’ 123’

29’

120’

P/N: 25G90R150

155’ 124’ 93’ 62’ 31’

160’ TOWER 15.3 OR 12.3 16.2 201’ 178’ 158’

3/16” EHS (399#)

142’ 132’ 128’

P/N: 25G90R160

165’

170’ TOWER 15.0 OR 12.2 16.0

132’

214’

99’

190’ 168’

66’ 33’

3/16” EHS (399#)

151’ 140’ 136’

P/N: 25G90R170

175’

180’ TOWER 14.8 OR 12.0 15.8

139’

227’

105’

200’ 178’

69’ 35’

3/16” EHS (399#)

160’ 148’ 144’

P/N: 25G90R180

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

25G

25AG2

BPC25G

13

1

1

3/16EHS

BG2142

1825’

24

FDNS GA25GD BASE ANCHOR 4

5/16THH 1/2TBE&J TBSAFETY 24

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

14

1

1

3/16EHS

BG2142

2425’

30

3

3/4x12PP 1

5

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 30

3

1

3

25G

25AG2

BPC25G

15

1

1

3/16EHS

BG2142

2600’

30

15

3

3 3/4x12PP 1

5

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 30

3

1

3

25G

25AG2

BPC25G

16

1

1

3/16EHS

BG2142

2750’

30

15

3

3

1

FDNS GA25GD BASE ANCHOR 5

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

17

1

1

3/16EHS

BG2142

2925’

30

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 5

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

180’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 180

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

170’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 170

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 30

160’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 160

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 30

150’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 150

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

1

3

140’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 140

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

CB1G AB2

29


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 185’ 148’ 111’

190’ TOWER 14.5 OR 11.9 15.6 239’ 212’

3/16” EHS (399#)

188’ 74’

169’

37’

156’ 152’

P/N: 25G90R190

30

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

18

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

3075’

30

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR 5

5/16THH 1/2TBE&J TBSAFETY 30

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

CB1G AB2

3

3

3

190’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 190

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 35’

40’ TOWER 13.4 OR 9.7 13.4 47’ 3/16” EHS (399#)

32’

P/N: 25G110R040 50’ TOWER 12.6 OR 9.1

45’

12.6 60’ 3/16” EHS (399#)

22’

46’

40’

P/N: 25G110R050

60’ TOWER 11.9 OR 8.7

55’

12.2 73’ 3/16” EHS (399#)

28’

56’

48’

P/N: 25G110R060

65’

70’ TOWER 11.3 OR 8.6 11.8 86’ 3/16” EHS (399#)

32’

64’

56’

P/N: 25G110R070

75’

80’ TOWER 10.9 OR 8.3 11.4 99’ 3/16” EHS (399#)

50’ 81’ 25’

69’ 64’

P/N: 25G110R080

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

3

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

175’

6

ANCHORS & GROUNDING INCLUDED

6

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

4

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

350’

12

12

3

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

5

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

425’

12

6

3

1

3

12

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

6

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

500’

12

1

2

CB1G AB2

6

3

3

1

FDNS GA25GD BASE ANCHOR 2

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

7

1

1

GUYS & CONNECTIONS INCLUDED

3/16 EHS

BG2142

800’

18

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

80’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 080

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

70’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 070

3/4x12PP

5/16 THH 1/2TBE&J TBSAFETY 18

60’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 060

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 12

50’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 050

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

1

3/4x12PP

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

3

40’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 040

FDNS GA25GD BASE ANCHOR CB1G AB2 2

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

1

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

31


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 90’ TOWER 10.5 OR 8.1

85’

11.2 111’ 3/16” EHS (399#)

56’ 91’ 28’

77’ 72’

P/N: 25G110R090 100’ TOWER 10.2 OR 7.9

95’

10.8 124’ 3/16” EHS (399#)

63’ 102’ 32’

86’ 80’

P/N: 25G110R100 110’ TOWER 9.9 OR 7.8

105’

10.6 137’ 3/16” EHS (399#)

70’ 112’ 35’

95’ 88’

P/N: 25G110R110

115’

120’ TOWER 9.7 OR 7.6 10.4 150’

86’

129’ 57’ 28’

3/16” EHS (399#)

112’ 100’ 96’

P/N: 25G110R120

125’ 93’

130’ TOWER 9.3 OR 7.5 10.2 163’ 140’

62’ 31’

3/16” EHS (399#)

121’ 109’ 104’

P/N: 25G110R130

32

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

8

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

900’

18

ANCHORS & GROUNDING INCLUDED

18

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

9

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1000’

18

18

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

10

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1100’

18

18

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

11

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

5/16THH

1575’

24

24

3

9

3

1

3

25G

25AG2

BPC25G

12

1

1

3/16EHS

BG2142

1700’

24

3

9

3

1

1

CB1G AB2

3 3/4x12PP 1

CB1G AB2

3

3

110’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 110

3/4x12PP 1

4

CB1G AB2

1/2TBE&J TBSAFETY 12

3

3

120’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 120

3/4x12PP 1

GA25GD BASEFDNS ANCHOR 4

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 24

100’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 100

FDNS GA25GD BASE ANCHOR

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

3/4x12PP

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

90’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 090

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

3

5/16THH 1/2TBE&J TBSAFETY

3

GUYS & CONNECTIONS INCLUDED

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

TOWER PARTS INCLUDED

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

3

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

3

3

130’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 130

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 140’ TOWER 9.2 OR 7.4

135’

10.0 175’

101’

151’ 67’

3/16” EHS (399#)

131’

33’

117’ 112’

P/N: 25G110R140 150’ TOWER 9.0 OR 7.3

145’

9.9

116’

188’ 167’

87’

148’ 58’

3/16” EHS (399#)

133’

29’

123’ 120’

P/N: 25G110R150 160’ TOWER 8.8 OR 7.2

155’

9.8 201’

124’

178’

93’

158’ 62’

3/16” EHS (399#)

142’

31’

132’ 128’

P/N: 25G110R160

170’ TOWER 8.7 OR 7.1

165’

9.7

138’

214’

110’

194’

83’

175’ 159’

55’

3/16” EHS (399#)

74’

28’

57’

50’

136’

P/N: 25G110R170

176’ 145’

180’ TOWER 8.6 OR 7.0 9.6 227’

116’

204’

87’

185’ 168’

58’ 29’

3/16” EHS (399#)

77’ 58’

50’

144’

P/N: 25G110R180

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

13

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1825’

24

ANCHORS & GROUNDING INCLUDED

24

CB1G AB2

3

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

14

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

2425’

30

30

3

1

FDNS GA25GD BASE ANCHOR 5

CB1G AB2

3

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

15

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

2600’

30

1

3

FDNS GA25GD BASE ANCHOR 5

CB1G AB2

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

1

1

3

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

GA25GD

BASE

16

1

1

6

CB2G

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

5/16THH

2800’

36

36

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

INNER OUTER ANCHOR ANCHOR

18

3

6

25G

25AG2

BPC25G

GA25GD

BASE

17

1

1

6

CB2G

3/16EHS

BG2142

5/16THH

2925’

36

36

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

INNER OUTER ANCHOR ANCHOR

AB2

6

6

AB2

180’ ROHN 25G Al l par ts shown i n tabl e are i nc l uded when ord er i ng Par t No: 25G110R 180

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

Al l par ts shown i n tabl e are i nc l uded when ord er i ng Par t No: 25G110R 170

1

1/2TBE&J TBSAFETY 18

170’ ROHN 25G

3/4x12PP

2

3

AB2

6

6

2

AB2

1/2TBE&J TBSAFETY

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

6

160’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 160

3/4x12PP

3

ANCHORS & GROUNDING INCLUDED

150’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 150

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 30

140’ ROHN 25G All par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 140

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

4

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

33


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 186’ 155’ 124’

190’ TOWER 8.5 OR 6.9 9.5 240’ 217’

93’

196’ 178’

62’

80’

31’

59’

3/16” EHS (399#)

50’

152’

P/N: 25G110R190

34

INNER OUTER ANCHOR ANCHOR

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

GA25GD

BASE

18

1

1

6

CB2G

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

5/16THH

1/2TBE&J

TBSAFETY

3100’

36

36

18

6

ANCHORS & GROUNDING INCLUDED

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 6

2

3

6

AB2

3/4x12PP

AB2

190’ ROHN 25G Al l par ts shown i n tabl e are i nc l uded when ord er i ng Par t No: 25G110R 190

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 40’ TOWER 10.8 OR 7.9

38’

11.2 50’ 3/16” EHS (399#)

32’

P/N: 25G130R040

48’

50’ TOWER 10.1 OR 7.5 10.0 62’ 3/16” EHS (399#)

22’

46’

40’

P/N: 25G130R050

58’

60’ TOWER 9.7 OR 7.2 9.8 75’ 3/16” EHS (399#)

28’

56’

48’

P/N: 25G130R060

68’

70’ TOWER 9.2 OR 7.0 9.6 88’ 3/16” EHS (399#)

32’

64’

56’

P/N: 25G130R070

78’

80’ TOWER 8.9 OR 6.8 9.4 101’ 3/16” EHS (399#)

50’ 81’ 25’

69’ 64’

P/N: 25G130R080

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

3

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

175’

6

ANCHORS & GROUNDING INCLUDED

6

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

4

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

350’

12

12

3

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

5

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

425’

12

2

6

3

1

CB1G AB2

3

12

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

6

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

500’

12

1

2

CB1G AB2

6

3

3

1

FDNS GA25GD BASE ANCHOR 2

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

7

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

800’

18

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

80’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 080

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

70’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 070

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 18

60’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 060

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 12

50’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 050

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

1

3/4x12PP

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

3

40’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 040

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

1

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

35


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 90’ TOWER 8.6 OR 6.7

88’

9.2 114’ 3/16” EHS (399#)

56’ 91’ 28’

77’ 72’

P/N: 25G130R090

98’

100’ TOWER 8.3 OR 6.5 9.0 127’ 3/16” EHS (399#)

63’ 102’ 32’

86’ 80’

P/N: 25G130R100

36

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

8

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

900’

18

ANCHORS & GROUNDING INCLUDED

3

18

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

9

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1000’

18

3

1

3 3/4x12PP 1

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

90’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G130R 090

FDNS GA25GD BASE ANCHOR

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

3

3

100’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G130R 100

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S

8 1/4”

1’ - 0”

2.00“ O.D. 1.87” I.D.

1’ - 6”

1.66“ O.D. 1.38” I.D. 1.25” N.P.T.

Set Screw 9’ - 9”

TOP SECTION 25AG COMES WITH TOP BUSHING INSTALLED, 1.31” I.D.

TOP SECTION 25AG2

TOP SECTION 25AG1

1’ - 1/4” 1’ - 5 1/4” 8’ - 3 1/2”

1’ - 4 3/4” 9’ - 3 1/2”

Set Screw

1’-3 3/4”

1’-3 3/4”

1’ - 3 3/4”

2.25” O.D. 2.08“ I.D.

1’ - 0”

1’ - 3” 9’ - 3 1/4” 1’ - 3”

9’ - 0” 1’ - 4”

8’ - 3/16”

2.25” O.D. 2.08“ I.D.

TOP SECTION 25AG3

Set Screw 2.75” O.D. 2.58“ I.D.

1’-3 3/4”

BEARING PLATE BPL25G TOP SECTION 25AG4

TOP PLATE APL25G

LONG LEGS PROVIDE EXTRA CLEARANCE FOR INSTALLATION OF EQUIPMENT. BOLTS TO TOP OF STANDARD SECTION. HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARINGS.

TOP SECTION 25AG5

TOP PLATE HOLE PATTERN IS THE SAME AS BPL25G.

TOP MOUNT 25TDMKD - NO MAST 25TDM2S3KD - 2 3/8” O.D. MAST 25TDM25S3KD - 2 7/8” O.D. MAST 25TDM3S3KD - 3 1/2” O.D. MAST 25TDM35S3KD - 4” O.D. MAST MOUNTING TUBE PROVIDED IS 7’ LONG.

FOR MOUNTING BEACON OR LIGHTNING ROD.

1’- 4”

BEARING/ACCESSORY SHELF BAS25G

HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARINGS ON TOP PLATE. ACCESSORY SHELF DRILLED FOR MOUNTING MANY POPULAR ROTORS.

5’ COPPER CLAD, MOUNTS TO APL25G.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

LIGHTNING ROD LRCL

37


G

GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S

CONCRETE BASE PLATE FOR GUYED & BRACKETED TOWERS BPC25G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. CONCRETE BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

PIER PIN 3/4X12PP FOR USE WITH BPC25G EMBEDDED IN CONCRETE. PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.

CONCRETE BASE PLATE FOR SELF-SUPPORTING TOWERS 25GSSB FOR USE WITH 5/8” x 12” (P/N: 260145G) BASE BOLTS (ORDERED SEPARATELY) IN SELF-SUPPORTING 25G TOWER APPLICATIONS.

5/8” x 12”

BASE BOLT & TEMPLATE KH8175A FOR USE WITH 25GSSB IN SELF-SUPPORTING 25G TOWER APPLICATIONS. KIT INCLUDES (1) TEMPLATE & (4) BASE BOLTS.

1/2” x 12”

HINGED BASE PLATE BPH25G* FOR USE WITH 1/2X12BB BASE BOLTS (ORDERED SEPARATELY). HINGED TO ALLOW TOWER TO BE ROTATED UP FROM BASE DURING INSTALLATION.

BASE BOLTS 1/2X12BB FOR USE WITH BPH 25G (6) REQUIRED, ORDERED SEPARATELY.

HINGED BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

TAPERED BASE 25TG* CAN BE USED WITH A4197L BASE INSULATOR OR WITH 3/4x12PP, ORDERED SEPARATELY.

3’4” SHORT BASE SB25G

3’4” HINGED SHORT BASE SBH25G*

5’ SHORT BASE SB25G5

FOR EMBEDMENT IN CONCRETE.

FOR EMBEDMENT IN CONCRETE.

SINGLE DRIVE-IN BASE SDB25G*

PEAK ROOF MOUNT PR25G*

TO BE DRIVEN DIRECTLY INTO GROUND.

ADJUSTABLE HINGED FEET CONFORM TO NEARLY ANY ROOF PITCH. BOLTS TO ROOF SURFACE.

WALL MOUNT 25GWM

INCLUDES BASE PLATE TO MOUNT 25G SECTION.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

38

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

PA R T S & A CC E S S O R I E S

1’ 7/8” - 1 1/8” O.D. Mounting Pipe 1’

FLAT ROOF MOUNT FR25G* BOLTS DIRECTLY TO FLAT ROOF SURFACE.

SIDE ARM MOUNT UHF25G FOR UHF & FM ANTENNAS.

FACE MOUNT DM25G2 - 2 3/8” O.D. 5’ LONG

DBS ANTENNA MOUNT KY2068A16 - 1.66” O.D. KY2068A15 - 1.50” O.D. KY2068A2 - 2.38” O.D. MOUNTING TUBE PROVIDED IS 3’ LONG.

Adjustable 2.5’ - 3.0’

SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.

TORQUE ARM STABILIZER ASSEMBLY TA25 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER.

ADJUSTABLE HOUSE BRACKET HB25AG 0 - 15” HB25BG 0 - 24” HB25CG 0 - 36”

HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 18” - 36” FROM WALL.

UNIVERSAL EAVE BRACKET EB2525G

HINGED CONNECTION ALLOWS TOWER LEG CLAMPS TO REMAIN PERPENDICULAR TO GROUND WHILE BOLT DOWN SUPPORTS ROTATE TO LAY FLAT ALONG PITCHED ROOF OR EAVE.

TORQUE BAR TB25D

OPTIONAL, FOR USE WITH GA25GD. REQUIRES (1) 3/8” SHACKLE FOR EACH BAR.

GUY BRACKET GA25GD MOUNTS TO TOWER AT ANY HORIZONTAL BRACE.

ACCESSORY SHELF AS25G FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

39


G

GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S Tower Leg

RP25G

THRUST BEARING TB3 - SUPPORTS UP TO 2” O.D. MAST. TB4 - SUPPORTS UP TO 3” O.D. MAST.

TOWER BUSHING TB50 - 1-1/4” I.D. X 2” O.D. TB75 - 1-1/2” I.D. X 2” O.D.

Tower Leg

FOR USE ON 25AG TOP SECTION

MOUNTS TO BAS25G, BPL25G AND 25AG4.

RP25G CM ROTOR POST 1.25” O.D. 1.08” I.D.

90º JOINTS 2590FF - BOTH ENDS OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO 25G SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS.

90º JOINTS 2590FM - ONE END SWAGED, ONE OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO 25G SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS.

ANTI-CLIMB PANELS 25ACL3 THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.

90º JOINTS 2590MM - BOTH ENDS SWAGED JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO 25G SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS.

SAFETY RING SR245 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS

TTFBH-C/P

PROFESSIONAL HARNESS

SAFETY CABLE SYSTEM ORDERING INFORMATION TOWER HEIGHT 50’ 100’ 150’ 200’

ERECTION FIXTURE EF2545 - 2 1/2” SHEAVE WITH 3/8“ I.D. GROOVE.

WORK PLATFORM WP25G SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

40

NOTE: ERECTION FIXTURES ARE FOR LIFTING ONE 10’ SECTION AT A TIME AND ARE NOT INTENDED FOR THE LIFTING OF PERSONNEL.

SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC

PART NUMBER TT05025 TT10025 TT15025 TT20025

SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 25G

A N C H O R I N F O R M AT I O N 81”

12” 3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4” 4” x 4” x 3/8” angle

2” 11/16”

GAC3455TOP

120”

12” 1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4” 5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP

REV G BASE GROUNDING BGK3GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp Ground Wire Clamp Ground Wire Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed o at 120 separation at 20’ spacing.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

41


G

GUYED TOWERS - 25G

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required

o

Top and bottom horizontal bars equally spaced

A B

C

D

Refer to page 43 for anchor rod installation angles.

42

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 25G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

25G | 90MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Rod Rod Number Angle GAC3455TOP 48 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37

Ground Line

Anchor Rod Angle

25G | 130MPH

25G | 110MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 48 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 36 GAC3455TOP 36 GAC3455TOP 40 GAC3455TOP 42 GAC3455TOP 41 GAC3455TOP 42 GAC3455TOP 43 GAC3455TOP 42

Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’

Rod Rod Number Angle GAC3455TOP 50 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 40 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38

o

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

43


G

GUYED TOWERS - 25G

S TA N D A R D B A S E P I E R S Pier Pin 4” Projection Grade

6”

(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps

No. 4 Circular ties, 3” Max. O.C. with 24” laps

B

Vertical bars equally spaced

ELEVATION VIEW

Alternate Square Pier

A

No. 4 Circular ties, 3” O.C. with 24” laps

CL

A

Vertical bars equally spaced

CL

PLAN VIEW

Base

A

B

Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier

CB1G* 2’ - 6” 4’ - 0”

1.0

(8) #7

CB2G

1.2

(10) #7

3’ - 0” 4’ - 0”

* Square pier option must be used for CB1G.

44

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.