ROHN G-Series Guyed Towers

Page 1


G

G-SERIES TOWERS

ROHN began manufacturing the G-Series line of towers in the early 1950’s. Starting with the ROHN No. 5 tower, there was an ever present drive for a superior tower design. The No. 5 soon led to the ROHN No. 6 and continued through the No.10, 11, 20, 25, 30, 40 and 50 towers. ROHN originally coated the lightweight towers with a hot-dipped enamel coating called RohnKote. The alternative to RohnKote was hot-dipped galvanizing. The galvanized option was identified by the now famous “G” suffix added to the tower model. The G-Series was born! The numbers have settled to the four models listed below and hot-dip galvanizing is the coating of choice for towers today. ROHN’s G-Series towers are designed for strength and versatility. The towers are constructed with high strength steel tubing or solid round legs. ROHN’s exclusive Zig-Zag solid-rod bracing provides exceptional strength. As they were in the 1950’s, each ROHN G-Series tower continues to be hot-dip galvanized for corrosion protection.

25G | 45G | 55G | 65G The 25G is a light weight tubular tower with solid braces. The tower sections are most often guyed, but can also be used in bracketed and self-supporting applications. Standard sections are 10’ in length, but are also available in a 7‘ length, which is UPS shippable. This tower model has several top options, as well as a variety of tower accessories. The 25G has several base options, including: base cast in concrete, base plate with anchor bolts and also a hinged base. Standard Design Tower Heights Guyed: Up to 190’ Bracketed: Up to 100‘ Self-Supporting: Up to 40’

25G | 45G | 55G | 65G The 45G is a light weight tower, available with tubular or solid round legs with solid braces. The tower sections are most often guyed, but can also be used in bracketed and self-supporting applications. Standard sections are 10’ in length, but are also available in a 20‘ length when ordering solid sections. This tower model has several top options, as well as a variety of tower accessories. The 45G has several base options, including: base cast in concrete, base plate with anchor bolts and also a hinged base. This tower is a true multi-use structure. Standard Design Tower Heights Guyed: Up to 300’ [45G] and 350’ [45GSR] Bracketed: Up to 100‘ Self-Supporting: Up to 45’

22

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G-SERIES TOWERS

G

25G | 45G | 55G | 65G The 55G is a tubular tower with solid braces that lends itself to a wide variety of uses, particularly where unusual wind loading and height requirements exist. The 55G was designed to provide excellent strength and rigidity. The tower sections are most often guyed, but can also be used in bracketed and self-supporting applications. Standard sections are 10’ in length. This tower model has several top options, as well as a variety of tower accessories. The 55G is available with a base cast in concrete as well as a tapered base option. Standard Design Tower Heights Guyed: Up to 400’ Bracketed: Up to 100‘ Self-Supporting: Up to 60’

25G | 45G | 55G | 65G The 65G is available with tubular or solid round legs with solid braces. The tower sections are most often guyed, but can also be used in self-supporting applications. Standard sections are 10’ and 20’ in length. This tower model has a variety of tower accessories, and is available with a base cast in concrete or a tapered base. Standard Design Tower Heights Guyed: Up to 500’ Self-Supporting: Up to 80’

The ROHN G-Series towers are assembled and installed quickly and are diverse enough for use by broadcasters, fire and police, military, ham and home use. The possibilities are endless with the G-Series towers. Over the long history of the G-Series, ROHN has developed a variety of options to improve the utility of each model. The G-Series has optional: • Standard and Shortened Sections • Guy Lug Sections • Four Leg (Square) Design of 25G • Double Braced Sections

• Double Braced Sections • Torque Arms • Roof Mounts • Top Mounts

• House Brackets • Base Options • Side Arms

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

23


G

GUYED TOWERS - 25G

S TA N D A R D 2 5 G G U Y E D T O W E R

ROHN 25G The first. The original.

includes

REV. F & REV. G

25G

GENERAL USE The 25G is available in the standard 10’ section length and a 7’ length which is UPS shippable. The 25G uses double bolted joints, proven to be the best method of joining tower sections for sturdiness and dependability. As a guyed structure, the 25G standard designs rise to a height of 190’.

FEATURES • Completely hot-dip galvanized after fabrication • Built on an 11 1/4” equilateral triangle design • High strength tubular legs joined by Zig-Zag®

cross members • Each 7’ or 10’ section contains all required nuts and bolts shipped with section • Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 40 for ordering information.

24

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D 2 5 G G U Y E D T O W E R SECTIONS 6 1/2” 9 3/4”

QUICK REFERENCE PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION

11 1/4”

1’ 6”

Optional Waveguide Brackets (KY2041A)

PAGES 37-40 PAGE 41 PAGES 41-44 2.25” O.D. 2.08” I.D. (14 GA.)

1’ 3” 9’ 9” 1 1/4” O.D. (16 GA.)

1 1/4” O.D. (16 GA.)

~ ~

5/16” O.D. Solid Bracing

Optional double braced sections are available upon request.

5/16” O.D. Solid Bracing

STANDARD TOP SECTION 25AG2 Additional 25G top sections are shown on page 37.

CONCRETE BASE PLATE BPC25G*

STANDARD SECTION 25G - 10’ Section

FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE.

OPTIONAL 7’ SECTION 25G7 - 7‘ Section

Additional base sections are available, please see page 38.

The 7’ Section is UPS shippable. * Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

25


G

GUYED TOWERS - 25G

BUYERS GUIDE S TA N D A R D D E S I G N S - 2 5 G 9 0 M P H R E V. G [ 3 - S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 16.6

22.6

35’

EPA (SQ. FT.) For Exposure C, Revision G

22.0 47’ 3/16” EHS (399#)

EPA (SQ. FT.), Revision F Guy Initial Tension

P/N 25G90R040 32’

P/N 25G90R040

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 25G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 41-44. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

26

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 35’

40’ TOWER 22.6 OR 16.6 22.0 47’ 3/16” EHS (399#)

32’

P/N: 25G90R040

45’

50’ TOWER 21.4 OR 15.8 21.0 60’ 3/16” EHS (399#)

23’

46’

40’

P/N: 25G90R050

55’

60’ TOWER 20.3 OR 15.2 20.2 73’ 3/16” EHS (399#)

28’

56’

48’

P/N: 25G90R060

65’

70’ TOWER 19.4 OR 14.7 19.4 86’ 3/16” EHS (399#)

32’

64’

56’

P/N: 25G90R070

75’

80’ TOWER 18.6 OR 14.3 18.8 99’ 3/16” EHS (399#)

50’ 81’ 25’

69’ 64’

P/N: 25G90R080

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

25G

25AG2

3

1

3/16EHS

BG2142

175’

6

BPC25G GA25GD 1

1

FDNS

BASE ANCHOR

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 6

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3 3/4x12PP

3

1

3

3

1

25G

25AG2

BPC25G

GA25GD

BASE ANCHOR

4

1

1

2

3/16EHS

BG2142

350’

12

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

5

1

1

3/16EHS

BG2142

425’

12

3

3

12

1

3

25G

25AG2

BPC25G

6

1

1

3/16EHS

BG2142

500’

12

1

2

CB1G AB2

6

3

3 3/4x12PP

FDNS GA25GD BASE ANCHOR 2

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

7

1

1

3/16EHS

BG2142

800’

18

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

80’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 080

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

70’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 070

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 18

60’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 060

1

5/16THH 1/2TBE&J TBSAFETY 12

50’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 050

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

1

CB1G AB2

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

FDNS

5/16THH 1/2TBE&J TBSAFETY 12

40’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 040

27


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 90’ TOWER 18.0 OR 13.9

85’

18.4 111’ 3/16” EHS (399#)

57’ 92’ 28’

77’ 72’

P/N: 25G90R090 100’ TOWER 17.5 OR 13.6

95’

18.0 124’ 3/16” EHS (399#)

63’ 102’ 31’

86’ 80’

P/N: 25G90R100

110’ TOWER 17.0 OR 13.4

105’

17.6 137’ 3/16” EHS (399#)

70’ 112’ 35’

95’ 88’

P/N: 25G90R110 120’ TOWER 16.6 OR 13.1

115’

17.2 150’

85’

128’ 55’

3/16” EHS (399#)

111’ 100’

28’

96’

P/N: 25G90R120

125’ 93’

130’ TOWER 16.2 OR 12.9 17.0 163’ 140’

62’ 31’

3/16” EHS (399#)

121’ 108’ 104’

P/N: 25G90R130

28

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

25G

25AG2

BPC25G

8

1

1

3/16EHS

BG2142

900’

18

GA25GD BASEFDNS ANCHOR 3

5/16THH 1/2TBE&J TBSAFETY 18

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

9

1

1

3/16EHS

BG2142

1000’

18

3

3/4x12PP 1

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

1

3

25G

25AG2

BPC25G

10

1

1

3/16EHS

BG2142

1100’

18

9

3

3 3/4x12PP 1

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

1

3

25G

25AG2

BPC25G

11

1

1

3/16EHS

BG2142

1575’

24

9

3

3

1

FDNS GA25GD BASE ANCHOR 4

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

12

1

1

3/16EHS

BG2142

1700’

24

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 4

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

120’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 120

3/4x12PP

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 24

110’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 110

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 24

100’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 2590R 100

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

1

3

90’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 090

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

CB1G AB2

3

3

130’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 130

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 140’ TOWER 15.9 OR 12.7

135’

16.6 175’

99’

149’ 66’

3/16” EHS (399#)

130’ 117’

33’

112’

P/N: 25G90R140 150’ TOWER 15.5 OR 12.5

145’

16.4

116’

188’

87’

167’ 148’

58’

3/16” EHS (399#)

133’ 123’

29’

120’

P/N: 25G90R150

155’ 124’ 93’ 62’ 31’

160’ TOWER 15.3 OR 12.3 16.2 201’ 178’ 158’

3/16” EHS (399#)

142’ 132’ 128’

P/N: 25G90R160

165’

170’ TOWER 15.0 OR 12.2 16.0

132’

214’

99’

190’ 168’

66’ 33’

3/16” EHS (399#)

151’ 140’ 136’

P/N: 25G90R170

175’

180’ TOWER 14.8 OR 12.0 15.8

139’

227’

105’

200’ 178’

69’ 35’

3/16” EHS (399#)

160’ 148’ 144’

P/N: 25G90R180

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

25G

25AG2

BPC25G

13

1

1

3/16EHS

BG2142

1825’

24

FDNS GA25GD BASE ANCHOR 4

5/16THH 1/2TBE&J TBSAFETY 24

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

14

1

1

3/16EHS

BG2142

2425’

30

3

3/4x12PP 1

5

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 30

3

1

3

25G

25AG2

BPC25G

15

1

1

3/16EHS

BG2142

2600’

30

15

3

3 3/4x12PP 1

5

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 30

3

1

3

25G

25AG2

BPC25G

16

1

1

3/16EHS

BG2142

2750’

30

15

3

3

1

FDNS GA25GD BASE ANCHOR 5

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

25G

25AG2

BPC25G

17

1

1

3/16EHS

BG2142

2925’

30

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 5

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

180’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G90R 180

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

170’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 170

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 30

160’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 160

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 30

150’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 150

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

1

3

140’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 140

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

CB1G AB2

29


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 185’ 148’ 111’

190’ TOWER 14.5 OR 11.9 15.6 239’ 212’

3/16” EHS (399#)

188’ 74’

169’

37’

156’ 152’

P/N: 25G90R190

30

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

18

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

3075’

30

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR 5

5/16THH 1/2TBE&J TBSAFETY 30

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

CB1G AB2

3

3

3

190’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G90R 190

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 35’

40’ TOWER 13.4 OR 9.7 13.4 47’ 3/16” EHS (399#)

32’

P/N: 25G110R040 50’ TOWER 12.6 OR 9.1

45’

12.6 60’ 3/16” EHS (399#)

22’

46’

40’

P/N: 25G110R050

60’ TOWER 11.9 OR 8.7

55’

12.2 73’ 3/16” EHS (399#)

28’

56’

48’

P/N: 25G110R060

65’

70’ TOWER 11.3 OR 8.6 11.8 86’ 3/16” EHS (399#)

32’

64’

56’

P/N: 25G110R070

75’

80’ TOWER 10.9 OR 8.3 11.4 99’ 3/16” EHS (399#)

50’ 81’ 25’

69’ 64’

P/N: 25G110R080

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

3

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

175’

6

ANCHORS & GROUNDING INCLUDED

6

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

4

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

350’

12

12

3

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

5

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

425’

12

6

3

1

3

12

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

6

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

500’

12

1

2

CB1G AB2

6

3

3

1

FDNS GA25GD BASE ANCHOR 2

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

7

1

1

GUYS & CONNECTIONS INCLUDED

3/16 EHS

BG2142

800’

18

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

80’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 080

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

70’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 070

3/4x12PP

5/16 THH 1/2TBE&J TBSAFETY 18

60’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 060

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 12

50’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 050

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

1

3/4x12PP

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

3

40’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 040

FDNS GA25GD BASE ANCHOR CB1G AB2 2

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

1

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

31


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 90’ TOWER 10.5 OR 8.1

85’

11.2 111’ 3/16” EHS (399#)

56’ 91’ 28’

77’ 72’

P/N: 25G110R090 100’ TOWER 10.2 OR 7.9

95’

10.8 124’ 3/16” EHS (399#)

63’ 102’ 32’

86’ 80’

P/N: 25G110R100 110’ TOWER 9.9 OR 7.8

105’

10.6 137’ 3/16” EHS (399#)

70’ 112’ 35’

95’ 88’

P/N: 25G110R110

115’

120’ TOWER 9.7 OR 7.6 10.4 150’

86’

129’ 57’ 28’

3/16” EHS (399#)

112’ 100’ 96’

P/N: 25G110R120

125’ 93’

130’ TOWER 9.3 OR 7.5 10.2 163’ 140’

62’ 31’

3/16” EHS (399#)

121’ 109’ 104’

P/N: 25G110R130

32

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

8

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

900’

18

ANCHORS & GROUNDING INCLUDED

18

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

9

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1000’

18

18

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

10

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1100’

18

18

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

11

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

5/16THH

1575’

24

24

3

9

3

1

3

25G

25AG2

BPC25G

12

1

1

3/16EHS

BG2142

1700’

24

3

9

3

1

1

CB1G AB2

3 3/4x12PP 1

CB1G AB2

3

3

110’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 110

3/4x12PP 1

4

CB1G AB2

1/2TBE&J TBSAFETY 12

3

3

120’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 120

3/4x12PP 1

GA25GD BASEFDNS ANCHOR 4

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 24

100’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 100

FDNS GA25GD BASE ANCHOR

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

3/4x12PP

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

90’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G110R 090

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

3

5/16THH 1/2TBE&J TBSAFETY

3

GUYS & CONNECTIONS INCLUDED

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

TOWER PARTS INCLUDED

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

3

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

3

3

130’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 130

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 140’ TOWER 9.2 OR 7.4

135’

10.0 175’

101’

151’ 67’

3/16” EHS (399#)

131’

33’

117’ 112’

P/N: 25G110R140 150’ TOWER 9.0 OR 7.3

145’

9.9

116’

188’ 167’

87’

148’ 58’

3/16” EHS (399#)

133’

29’

123’ 120’

P/N: 25G110R150 160’ TOWER 8.8 OR 7.2

155’

9.8 201’

124’

178’

93’

158’ 62’

3/16” EHS (399#)

142’

31’

132’ 128’

P/N: 25G110R160

170’ TOWER 8.7 OR 7.1

165’

9.7

138’

214’

110’

194’

83’

175’ 159’

55’

3/16” EHS (399#)

74’

28’

57’

50’

136’

P/N: 25G110R170

176’ 145’

180’ TOWER 8.6 OR 7.0 9.6 227’

116’

204’

87’

185’ 168’

58’ 29’

3/16” EHS (399#)

77’ 58’

50’

144’

P/N: 25G110R180

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

13

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1825’

24

ANCHORS & GROUNDING INCLUDED

24

CB1G AB2

3

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

14

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

2425’

30

30

3

1

FDNS GA25GD BASE ANCHOR 5

CB1G AB2

3

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

15

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

2600’

30

1

3

FDNS GA25GD BASE ANCHOR 5

CB1G AB2

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

1

1

3

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

GA25GD

BASE

16

1

1

6

CB2G

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

5/16THH

2800’

36

36

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

INNER OUTER ANCHOR ANCHOR

18

3

6

25G

25AG2

BPC25G

GA25GD

BASE

17

1

1

6

CB2G

3/16EHS

BG2142

5/16THH

2925’

36

36

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

INNER OUTER ANCHOR ANCHOR

AB2

6

6

AB2

180’ ROHN 25G Al l par ts shown i n tabl e are i nc l uded when ord er i ng Par t No: 25G110R 180

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

Al l par ts shown i n tabl e are i nc l uded when ord er i ng Par t No: 25G110R 170

1

1/2TBE&J TBSAFETY 18

170’ ROHN 25G

3/4x12PP

2

3

AB2

6

6

2

AB2

1/2TBE&J TBSAFETY

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

6

160’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 160

3/4x12PP

3

ANCHORS & GROUNDING INCLUDED

150’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 150

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 30

140’ ROHN 25G All par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G110R 140

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

4

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

33


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 186’ 155’ 124’

190’ TOWER 8.5 OR 6.9 9.5 240’ 217’

93’

196’ 178’

62’

80’

31’

59’

3/16” EHS (399#)

50’

152’

P/N: 25G110R190

34

INNER OUTER ANCHOR ANCHOR

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

GA25GD

BASE

18

1

1

6

CB2G

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

5/16THH

1/2TBE&J

TBSAFETY

3100’

36

36

18

6

ANCHORS & GROUNDING INCLUDED

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 6

2

3

6

AB2

3/4x12PP

AB2

190’ ROHN 25G Al l par ts shown i n tabl e are i nc l uded when ord er i ng Par t No: 25G110R 190

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

S TA N D A R D D E S I G N - 2 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 40’ TOWER 10.8 OR 7.9

38’

11.2 50’ 3/16” EHS (399#)

32’

P/N: 25G130R040

48’

50’ TOWER 10.1 OR 7.5 10.0 62’ 3/16” EHS (399#)

22’

46’

40’

P/N: 25G130R050

58’

60’ TOWER 9.7 OR 7.2 9.8 75’ 3/16” EHS (399#)

28’

56’

48’

P/N: 25G130R060

68’

70’ TOWER 9.2 OR 7.0 9.6 88’ 3/16” EHS (399#)

32’

64’

56’

P/N: 25G130R070

78’

80’ TOWER 8.9 OR 6.8 9.4 101’ 3/16” EHS (399#)

50’ 81’ 25’

69’ 64’

P/N: 25G130R080

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

3

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

175’

6

ANCHORS & GROUNDING INCLUDED

6

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

4

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

350’

12

12

3

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

5

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

425’

12

2

6

3

1

CB1G AB2

3

12

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

6

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

500’

12

1

2

CB1G AB2

6

3

3

1

FDNS GA25GD BASE ANCHOR 2

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

7

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

800’

18

CB1G AB2

3

3

1

FDNS GA25GD BASE ANCHOR 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

3

3

80’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 080

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

70’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 070

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 18

60’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 060

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY 12

50’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 050

3/4x12PP

5/16THH 1/2TBE&J TBSAFETY

3

1

3/4x12PP

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

3

3

40’ ROHN 25G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 25G130R 040

FDNS GA25GD BASE ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

ANCHORS & GROUNDING INCLUDED

1

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

35


G

GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 90’ TOWER 8.6 OR 6.7

88’

9.2 114’ 3/16” EHS (399#)

56’ 91’ 28’

77’ 72’

P/N: 25G130R090

98’

100’ TOWER 8.3 OR 6.5 9.0 127’ 3/16” EHS (399#)

63’ 102’ 32’

86’ 80’

P/N: 25G130R100

36

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

8

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

900’

18

ANCHORS & GROUNDING INCLUDED

3

18

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

TOWER PARTS INCLUDED

25G

25AG2

BPC25G

9

1

1

GUYS & CONNECTIONS INCLUDED

3/16EHS

BG2142

1000’

18

3

1

3 3/4x12PP 1

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

90’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G130R 090

FDNS GA25GD BASE ANCHOR

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY

3

ANCHORS & GROUNDING INCLUDED

FDNS GA25GD BASE ANCHOR

3

3

100’ ROHN 25G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 25G130R 100

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S

8 1/4”

1’ - 0”

2.00“ O.D. 1.87” I.D.

1’ - 6”

1.66“ O.D. 1.38” I.D. 1.25” N.P.T.

Set Screw 9’ - 9”

TOP SECTION 25AG COMES WITH TOP BUSHING INSTALLED, 1.31” I.D.

TOP SECTION 25AG2

TOP SECTION 25AG1

1’ - 1/4” 1’ - 5 1/4” 8’ - 3 1/2”

1’ - 4 3/4” 9’ - 3 1/2”

Set Screw

1’-3 3/4”

1’-3 3/4”

1’ - 3 3/4”

2.25” O.D. 2.08“ I.D.

1’ - 0”

1’ - 3” 9’ - 3 1/4” 1’ - 3”

9’ - 0” 1’ - 4”

8’ - 3/16”

2.25” O.D. 2.08“ I.D.

TOP SECTION 25AG3

Set Screw 2.75” O.D. 2.58“ I.D.

1’-3 3/4”

BEARING PLATE BPL25G TOP SECTION 25AG4

TOP PLATE APL25G

LONG LEGS PROVIDE EXTRA CLEARANCE FOR INSTALLATION OF EQUIPMENT. BOLTS TO TOP OF STANDARD SECTION. HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARINGS.

TOP SECTION 25AG5

TOP PLATE HOLE PATTERN IS THE SAME AS BPL25G.

TOP MOUNT 25TDMKD - NO MAST 25TDM2S3KD - 2 3/8” O.D. MAST 25TDM25S3KD - 2 7/8” O.D. MAST 25TDM3S3KD - 3 1/2” O.D. MAST 25TDM35S3KD - 4” O.D. MAST MOUNTING TUBE PROVIDED IS 7’ LONG.

FOR MOUNTING BEACON OR LIGHTNING ROD.

1’- 4”

BEARING/ACCESSORY SHELF BAS25G

HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARINGS ON TOP PLATE. ACCESSORY SHELF DRILLED FOR MOUNTING MANY POPULAR ROTORS.

5’ COPPER CLAD, MOUNTS TO APL25G.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

LIGHTNING ROD LRCL

37


G

GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S

CONCRETE BASE PLATE FOR GUYED & BRACKETED TOWERS BPC25G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. CONCRETE BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

PIER PIN 3/4X12PP FOR USE WITH BPC25G EMBEDDED IN CONCRETE. PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.

CONCRETE BASE PLATE FOR SELF-SUPPORTING TOWERS 25GSSB FOR USE WITH 5/8” x 12” (P/N: 260145G) BASE BOLTS (ORDERED SEPARATELY) IN SELF-SUPPORTING 25G TOWER APPLICATIONS.

5/8” x 12”

BASE BOLT & TEMPLATE KH8175A FOR USE WITH 25GSSB IN SELF-SUPPORTING 25G TOWER APPLICATIONS. KIT INCLUDES (1) TEMPLATE & (4) BASE BOLTS.

1/2” x 12”

HINGED BASE PLATE BPH25G* FOR USE WITH 1/2X12BB BASE BOLTS (ORDERED SEPARATELY). HINGED TO ALLOW TOWER TO BE ROTATED UP FROM BASE DURING INSTALLATION.

BASE BOLTS 1/2X12BB FOR USE WITH BPH 25G (6) REQUIRED, ORDERED SEPARATELY.

HINGED BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

TAPERED BASE 25TG* CAN BE USED WITH A4197L BASE INSULATOR OR WITH 3/4x12PP, ORDERED SEPARATELY.

3’4” SHORT BASE SB25G

3’4” HINGED SHORT BASE SBH25G*

5’ SHORT BASE SB25G5

FOR EMBEDMENT IN CONCRETE.

FOR EMBEDMENT IN CONCRETE.

SINGLE DRIVE-IN BASE SDB25G*

PEAK ROOF MOUNT PR25G*

TO BE DRIVEN DIRECTLY INTO GROUND.

ADJUSTABLE HINGED FEET CONFORM TO NEARLY ANY ROOF PITCH. BOLTS TO ROOF SURFACE.

WALL MOUNT 25GWM

INCLUDES BASE PLATE TO MOUNT 25G SECTION.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

38

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 25G

G

PA R T S & A CC E S S O R I E S

1’ 7/8” - 1 1/8” O.D. Mounting Pipe 1’

FLAT ROOF MOUNT FR25G* BOLTS DIRECTLY TO FLAT ROOF SURFACE.

SIDE ARM MOUNT UHF25G FOR UHF & FM ANTENNAS.

FACE MOUNT DM25G2 - 2 3/8” O.D. 5’ LONG

DBS ANTENNA MOUNT KY2068A16 - 1.66” O.D. KY2068A15 - 1.50” O.D. KY2068A2 - 2.38” O.D. MOUNTING TUBE PROVIDED IS 3’ LONG.

Adjustable 2.5’ - 3.0’

SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.

TORQUE ARM STABILIZER ASSEMBLY TA25 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER.

ADJUSTABLE HOUSE BRACKET HB25AG 0 - 15” HB25BG 0 - 24” HB25CG 0 - 36”

HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 18” - 36” FROM WALL.

UNIVERSAL EAVE BRACKET EB2525G

HINGED CONNECTION ALLOWS TOWER LEG CLAMPS TO REMAIN PERPENDICULAR TO GROUND WHILE BOLT DOWN SUPPORTS ROTATE TO LAY FLAT ALONG PITCHED ROOF OR EAVE.

TORQUE BAR TB25D

OPTIONAL, FOR USE WITH GA25GD. REQUIRES (1) 3/8” SHACKLE FOR EACH BAR.

GUY BRACKET GA25GD MOUNTS TO TOWER AT ANY HORIZONTAL BRACE.

ACCESSORY SHELF AS25G FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

39


G

GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S Tower Leg

RP25G

THRUST BEARING TB3 - SUPPORTS UP TO 2” O.D. MAST. TB4 - SUPPORTS UP TO 3” O.D. MAST.

TOWER BUSHING TB50 - 1-1/4” I.D. X 2” O.D. TB75 - 1-1/2” I.D. X 2” O.D.

Tower Leg

FOR USE ON 25AG TOP SECTION

MOUNTS TO BAS25G, BPL25G AND 25AG4.

RP25G CM ROTOR POST 1.25” O.D. 1.08” I.D.

90º JOINTS 2590FF - BOTH ENDS OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO 25G SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS.

90º JOINTS 2590FM - ONE END SWAGED, ONE OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO 25G SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS.

ANTI-CLIMB PANELS 25ACL3 THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.

90º JOINTS 2590MM - BOTH ENDS SWAGED JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO 25G SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS.

SAFETY RING SR245 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS

TTFBH-C/P

PROFESSIONAL HARNESS

SAFETY CABLE SYSTEM ORDERING INFORMATION TOWER HEIGHT 50’ 100’ 150’ 200’

ERECTION FIXTURE EF2545 - 2 1/2” SHEAVE WITH 3/8“ I.D. GROOVE.

WORK PLATFORM WP25G SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

40

NOTE: ERECTION FIXTURES ARE FOR LIFTING ONE 10’ SECTION AT A TIME AND ARE NOT INTENDED FOR THE LIFTING OF PERSONNEL.

SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC

PART NUMBER TT05025 TT10025 TT15025 TT20025

SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 25G

A N C H O R I N F O R M AT I O N 81”

12” 3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4” 4” x 4” x 3/8” angle

2” 11/16”

GAC3455TOP

120”

12” 1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4” 5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP

REV G BASE GROUNDING BGK3GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp Ground Wire Clamp Ground Wire Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed o at 120 separation at 20’ spacing.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

41


G

GUYED TOWERS - 25G

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required

o

Top and bottom horizontal bars equally spaced

A B

C

D

Refer to page 43 for anchor rod installation angles.

42

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 25G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

25G | 90MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Rod Rod Number Angle GAC3455TOP 48 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37

Ground Line

Anchor Rod Angle

25G | 130MPH

25G | 110MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 48 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 37 GAC3455TOP 36 GAC3455TOP 36 GAC3455TOP 40 GAC3455TOP 42 GAC3455TOP 41 GAC3455TOP 42 GAC3455TOP 43 GAC3455TOP 42

Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’

Rod Rod Number Angle GAC3455TOP 50 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 40 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38

o

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

43


G

GUYED TOWERS - 25G

S TA N D A R D B A S E P I E R S Pier Pin 4” Projection Grade

6”

(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps

No. 4 Circular ties, 3” Max. O.C. with 24” laps

B

Vertical bars equally spaced

ELEVATION VIEW

Alternate Square Pier

A

No. 4 Circular ties, 3” O.C. with 24” laps

CL

A

Vertical bars equally spaced

CL

PLAN VIEW

Base

A

B

Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier

CB1G* 2’ - 6” 4’ - 0”

1.0

(8) #7

CB2G

1.2

(10) #7

3’ - 0” 4’ - 0”

* Square pier option must be used for CB1G.

44

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 45G

S TA N D A R D 4 5 G G U Y E D T O W E R

ROHN 45G The first. The original.

includes

REV. F & REV. G

45G

GENERAL USE The 45G is a true multi-use structure that provides excellent strength for applications up to 300’, It is offered with heavy steel round legs to satisfy a variety of needs under varied conditions.

FEATURES • Completely hot-dip galvanized after fabrication • Built on a 16 3/4” equilateral triangle design • High strength tubular legs joined by Zig-Zag®

cross members • Each section contains all required nuts and bolts shipped with section • Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 65 for ordering information.

46

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D 4 5 G G U Y E D T O W E R SECTIONS 9 11/16” 14 1/2”

QUICK REFERENCE PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION

16 3/4”

1’ 6”

PAGES 63-65 PAGE 66 PAGES 66-69

2.38” O.D. 2.07” I.D.

Optional Waveguide Brackets (KY2041A) 9’ 6” 2’ 0”

1 1/4” O.D. (14 GA.)

1 1/4” O.D. (14 GA.)

7/16” O.D. Solid Bracing

7/16” O.D. Solid Bracing STANDARD TOP SECTION 45AG2 Optional double braced sections are available upon request.

Additional 45G top sections are shown on page 63.

CONCRETE BASE PLATE BPC45G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE.

STANDARD SECTION 45G - 10’ Section

Additional base sections are available, please see page 64.

* Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

47


G

GUYED TOWERS - 45G

BUYERS GUIDE S TA N D A R D D E S I G N S - 4 5 G 9 0 M P H R E V. G [ 3 - S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 23.1

31.4

31’

EPA (SQ. FT.) For Exposure C, Revision G

22.6 45’ 3/16” EHS (399#)

EPA (SQ. FT.), Revision F Guy Initial Tension

P/N 45G90R040 40’

P/N 45G90R040

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 45G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 66-69. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

48

Phone (309) 566-3000 • Fax (309) 566-3079• www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


49


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 90’ TOWER 25.0 OR 19.4

85’

17.6 111’ 3/16” EHS (399#)

45’

85’

72’

P/N: 45G90R090 100’ TOWER 24.3 OR 18.9

85’

17.0 117’ 1/4” EHS (665#)

45’

92’

3/16” EHS (399#)

80’

P/N: 45G90R100 110’ TOWER 23.6 OR 18.6

105’

16.4 137’ 3/16” EHS (399#)

65’ 109’ 35’

95’ 88’

P/N: 45G90R110

120’ TOWER 23.0 OR 18.2

105’

16.0 142’ 3/16” EHS (399#)

65’ 116’ 35’

1/4” EHS (665#)

102’ 96’

P/N: 45G90R120 130’ TOWER 22.5 OR 17.9

125’

15.6 163’ 3/16” EHS (399#)

85’ 134’ 45’

113’ 104’

P/N: 45G90R130

50

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

45G

45AG2

BPC45G

8

1

1

3/16EHS

BG2142

625’

12

FDNS GA45GD BASE ANCHOR 2

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 12

6

3 3/4x12PP

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

9

1

1

3

1

FDNS GA45GD BASE ANCHOR 2

CB1G AB2

GUYS & CONNECTIONS INCLUDED

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J

ANCHORS & GROUNDING INCLUDED

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

300’

6

375’

3

3

1

1

3

45G

45AG2

BPC45G

10

1

1

3/16EHS

BG2142

1100’

18

6

6

6

6

FDNS GA45GD BASE ANCHOR CB1G AB2

3

18

3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

45G

45AG2

BPC45G

11

1

1

1

3

FDNS GA45GD BASE ANCHOR 3

CB1G AB2

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J

ANCHORS & GROUNDING INCLUDED

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

12

475’

3

3

1

1

3

45G

45AG2

BPC45G

12

1

1

3/16EHS

BG2142

1325’

18

1

3

3

CB1G AB2

5/16THH 1/2TBE&J TBSAFETY 18

3

120’ ROHN 45G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45G90R 120

FDNS GA45GD BASE ANCHOR

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

9

6

12

6

110’ ROHN 45G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45G90R 110

3/4x12PP

GUYS & CONNECTIONS INCLUDED

700’

100’ ROHN 45G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45G90R 100

3

5/16THH 1/2TBE&J TBSAFETY

3

90’ ROHN 45G Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45G90R 090

3

3

130’ ROHN 45G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45G90R 130

3/4x12PP 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D D E S I G N - 4 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 140’ TOWER 22.0 OR 17.6

125’

15.2 168’ 1/4” EHS (665#)

85’ 141’ 45’

3/16” EHS (399#)

121’ 112’

P/N: 45G90R140

145’ 105’

150’ TOWER 21.6 OR 17.4 14.8 188’ 159’

65’ 35’

3/16” EHS (399#)

136’ 125’ 120’

P/N: 45G90R150

145’ 105’

160’ TOWER 21.2 OR 17.1 14.4 193’ 166’

65’ 35’

144’

1/4” EHS (665#) 3/16” EHS (399#)

133’ 128’

P/N: 45G90R160

165’ 125’

170’ TOWER 20.8 OR 16.9 14.2 214’ 185’

85’ 45’

160’

1/4” EHS (665#) 3/16” EHS (399#)

143’ 136’

P/N: 45G90R170

165’ 125’

180’ TOWER 20.5 OR 16.7 14.0 219’ 191’

85’ 45’

167’

1/4” EHS (665#) 3/16” EHS (399#)

151’ 144’

P/N: 45G90R180

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

45G

45AG2

BPC45G

13

1

1

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

850’

6

12

550’

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

14

1

1

3/16EHS

BG2142

1950’

24

3

1

3

FDNS GA45GD BASE ANCHOR 4

CB1G AB2

24

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

15

1

1

Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45G90R 150

3

12

3/4x12PP 1

3

GA45GD BASEFDNS ANCHOR 4

CB1G AB2

160’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 160

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1425’

6

18

625’

18

12

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

16

1

1

1

3

3

FDNS GA45GD BASE ANCHOR 4

CB1G AB2

ANCHORS & GROUNDING INCLUDED

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY

ANCHORS & GROUNDING INCLUDED

150’ ROHN 45G

5/16THH 1/2TBE&J TBSAFETY

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J

GUYS & CONNECTIONS INCLUDED

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 140

9

6

GUYS & CONNECTIONS INCLUDED

TOWER PARTS INCLUDED

140’ ROHN 45G

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J

1575’

18

700’

3

1

3

3

1

45G

45AG2

BPC45G

17

1

1

12

6

18

6

170’ ROHN 45G Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45G90R 170

3

GA45GD BASEFDNS ANCHOR 4

CB1G AB2

180’ ROHN 45G

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1625’

18

700’

6

18

6

12

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 180

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

3

1

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

51


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 185’ 145’ 105’ 65’ 35’

190’ TOWER 20.2 OR 16.5 13.6 239’ 3/16” EHS 210’ (399#) 185’ 165’ 156’ 152’

P/N: 45G90R190

185’ 145’ 105’ 65’ 35’

200’ TOWER 19.8 OR 16.3 11.4 245’ 1/4” EHS 216’ (665#) 191’ 173’

3/16” EHS (399#)

164’ 160’

P/N: 45G90R200

205’

210’ TOWER 19.5 OR 16.1 11.2

165’ 125’

265’ 235’ 209’

85’ 45’

3/16” EHS (399#)

113’ 87’ 75’

168’

P/N: 45G90R210

205’

220’ TOWER 19.3 OR 16.0 11.0 270’

165’ 125’ 85’ 45’

241’ 216’

1/4” EHS (665#) 3/16” EHS (399#)

113’ 87’ 75’

176’

P/N: 45G90R220

225’ 185’ 145’ 105’ 65’ 35’

230’ TOWER 19.1 OR 15.8 10.6 291’ 261’ 234’

3/16” EHS (399#)

212’ 85’ 65’ 55’

184’

P/N: 45G90R230

52

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

45G

45AG2

BPC45G

18

1

1

3/16EHS

BG2142

3050’

30

FDNS GA45GD BASE ANCHOR CB1G AB2

5

30

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

BPC45G

APL45G

20

1

1

1

FDNS GA45GD BASE ANCHOR 5

AB2

CB1G

200’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G90R 200

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 2375’

24

800’

6

24

6

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

APL45G

BPC45G

21

1

1

3/16EHS

BG2142

2900’

30

3

5

30

6

2

3

45G

BPC45G

APL45G

22

1

1

15

5

6

2

3

45G

APL45G

BPC45G

23

1

1

3/16EHS

BG2142

3675’

36

6

2

AB2

24

6 3/4x12PP 1

AB2

220’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 220

3/8THH 1/2TBE&J 6

15

3/4x12PP TBSAFETY 1

6

INNER OUTER GA45GD BASE ANCHOR ANCHOR

6

18

BGK3GGX CPC.5/.75 3

CB2G AB1

6

5/16THH 1/2TBE&J 36

210’ ROHN 45G Al l par ts shown i n tabl e a re i n cl uded when order i ng Par t No: 45G90R 210

INNER OUTER GA45GD BASE ANCHOR ANCHOR

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

GAC3455TOP AGK1GGX

CB2G AB2

6

6

24

875’

3

5/16THH 1/2TBE&J TBSAFETY

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

2100’

1

INNER OUTER GA45GD BASE ANCHOR ANCHOR

ANCHORS & GROUNDING INCLUDED

ANCHORS & GROUNDING INCLUDED

3/4x12PP

3

3/16EHS 1/4EHS BG2142 BG2144 5/16THH

GUYS & CONNECTIONS INCLUDED

Al l p ar ts shown i n tabl e a re i n c l uded when order i ng Par t No: 45G90R 190

3

15

GUYS & CONNECTIONS INCLUDED

TOWER PARTS INCLUDED

190’ ROHN 45G

5/16THH 1/2TBE&J TBSAFETY

6

CB2G AB1

AB2

TBSAFETY 6 3/4x12PP

230’ ROHN 45G Al l par ts shown i n tabl e a re i n cl ud ed when ord er i ng Par t No: 45G90R 230

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D D E S I G N - 4 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 225’ 185’ 145’

240’ TOWER 18.9 OR 15.7 10.4 296’ 267’ 241’

105’

219’

65’ 35’

1/4” EHS (665#) 3/16” EHS (399#)

85’ 65’ 55’

192’

P/N: 45G90R240 250’ TOWER 18.6 OR 15.6

245’

10.4

205’

316’ 286’

165’

259’

125’

236’

85’

1/4” EHS (665#) 3/16” EHS (399#)

113’ 87’

45’

75’

200’

P/N: 45G90R250 260’ TOWER 18.4 OR 15.5

245’

10.2

205’

321’ 292’

165’

265’

125’

243’

85’

1/4” EHS (665#) 3/16” EHS (399#)

113’ 87’

45’

75’

208’

P/N: 45G90R260 270’ TOWER 18.2 OR 15.4

265’

10.0

225’

342’ 312’

185’

284’

145’

260’

105’ 65’ 35’

138’ 111’ 97’

1/4” EHS (665#) 3/16” EHS (399#)

90’

216’

P/N: 45G90R270

265’ 225’ 185’ 145’ 105’ 65’ 35’

280’ TOWER 18.0 OR 15.2 9.8 347’ 317’ 291’ 267’ 138’ 111’ 97’

1/4” EHS (665#) 3/16” EHS (399#)

90’

224’

P/N: 45G90R280

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45G

BPC45G

APL45G

24

1

1

INNER OUTER GA45GD BASE ANCHOR ANCHOR

6

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 2800’

6

30

950’

30

CB2G AB1

AB2

3/8THH

1/2TBE&J

6

18

240’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 240

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

45G

BPC45G

APL45G

25

1

1

6

INNER OUTER GA45GD BASE ANCHOR ANCHOR

6

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3125’

30

1025’

6

6

1

30

CB2G AB1

AB2

3/8THH

1/2TBE&J

6

18

250’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G90R 250

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

45G

BPC45G

APL45G

26

1

1

6

INNER OUTER GA45GD BASE ANCHOR ANCHOR

6

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3200’

30

1025’

6

6

1

30

CB3G AB2

AB2

3/8THH

1/2TBE&J

6

18

260’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G90R 260

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

45G

BPC45G

APL45G

27

1

1

6

INNER OUTER GA45GD BASE ANCHOR ANCHOR

7

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3825’

36

1100’

6

6

1

36

CB3G AB2

AB2

3/8THH

1/2TBE&J

6

21

270’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G90R 270

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

45G

BPC45G

APL45G

28

1

1

6

INNER OUTER GA45GD BASE ANCHOR ANCHOR

7

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3900’

36

1125’

6

6

1

36

CB3G AB2

AB2

3/8THH

1/2TBE&J

6

21

280’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G90R 280

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

6

1

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

53


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 285’ 245’ 205’ 165’ 125’ 85’ 45’

290’ TOWER 17.8 OR 15.1 9.6 367’ 337’ 310’ 285’

1/4” EHS (665#) 3/16” EHS (399#)

163’ 135’ 114’

105’

232’

P/N: 45G90R290

285’ 245’ 205’ 165’ 125’ 85’ 45’

300’ TOWER 17.6 OR 15.0 9.6 373’ 343’ 316’ 291’

1/4” EHS (665#) 3/16” EHS (399#)

163’ 135’ 114’

105’

240’

P/N: 45G90R300

54

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45G

BPC45G

APL45G

29

1

1

INNER OUTER GA45GD BASE ANCHOR ANCHOR

7

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 4275’

36

1175’

6

36

CB3G AB2

AB2

3/8THH

1/2TBE&J

6

21

290’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 290

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

45G

BPC45G

APL45G

30

1

1

6

INNER OUTER GA45GD BASE ANCHOR ANCHOR

7

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 4350’

36

1200’

6

6

1

36

CB3G AB2

AB2

3/8THH

1/2TBE&J

6

21

300’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G90R 300

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 6

2

3

6

1

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D D E S I G N - 4 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 31’

40’ TOWER 21.3 OR 15.5 21.6 45’ 1/4” EHS (665#)

32’

P/N: 45G110R040

41’

50’ TOWER 19.9 OR 14.7 20.2 57’ 1/4” EHS (665#)

40’

P/N: 45G110R050

51’ 25’

60’ TOWER 18.9 OR 14.1 19.0 70’ 54’

1/4” EHS (665#) 3/16” EHS (399#)

48’

P/N: 45G110R060

61’ 29’

70’ TOWER 18.0 OR 13.7 18.2 83’ 63’

1/4” EHS (665#) 3/16” EHS (399#)

56’

P/N: 45G110R070

71’ 35’

80’ TOWER 17.4 OR 13.4 17.4 96’ 73’

1/4” EHS (665#) 3/16” EHS (399#)

64’

P/N: 45G110R080

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

GA45GD BASEFDNS ANCHOR

45G

45AG2

BPC45G

3

1

1

1

1/4EHS

BG2144

3/8THH

1/2TBE&J

TBSAFETY

150’

6

6

3

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

3

45G

45AG2

BPC45G

4

1

1

1

1/4EHS

BG2144

3/8THH

1/2TBE&J

TBSAFETY

200’

6

6

3

3

1

3

GA45GD BASEFDNS ANCHOR

3

45G

45AG2

BPC45G

5

1

1

50’ ROHN 45G

CB1G AB2

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 1

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 040

3/4x12PP

3

3

40’ ROHN 45G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 050

3/4x12PP 1

3

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

60’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 060

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 175’

6

225’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

6

1

1

6 3/4x12PP TBSAFETY 1

3

3

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

70’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 070

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 225’

6

275’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

7

1

1

6 3/4x12PP TBSAFETY 1

3

3

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

80’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 080

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 250’

6

325’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

3

6 3/4x12PP TBSAFETY 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

3

55


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 81’ 39’

90’ TOWER 16.8 OR 13.0 16.8 108’ 82’

1/4” EHS (665#) 3/16” EHS (399#)

72’

P/N: 45G110R090

91’ 61’

100’ TOWER 16.3 OR 12.7 16.2 121’ 101’

31’

86’

1/4” EHS (665#) 3/16” EHS (399#)

80’

P/N: 45G110R100

101’ 67’

110’ TOWER 15.8 OR 12.5 15.6 134’ 111’

34’

94’

1/4” EHS (665#) 3/16” EHS (399#)

88’

P/N: 45G110R110

111’ 75’

120’ TOWER 15.4 OR 12.2 15.2 147’ 122’

35’

102’

1/4” EHS (665#) 3/16” EHS (399#)

96’

P/N: 45G110R120

121’ 78’

130’ TOWER 15.1 OR 12.0 14.8 160’ 130’

35’

110’

1/4” EHS (665#) 3/16” EHS (399#)

104’

P/N: 45G110R130

56

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45G

45AG2

BPC45G

8

1

1

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

90’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 090

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 275’

6

350’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

9

1

1

6 3/4x12PP TBSAFETY 1

3

3

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

100’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 100

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 600’

12

400’

6

12

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

10

1

1

9 3/4x12PP TBSAFETY 1

3

3

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

110’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 110

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 675’

12

450’

6

12

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

11

1

1

9 3/4x12PP TBSAFETY 1

3

3

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

120’ ROHN 45G

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’

12

475’

6

12

6

9

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 120

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

12

1

1

3

1

3

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

130’ ROHN 45G

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 775’

12

525’

6

12

6

9

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 130

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

3

1

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D D E S I G N - 4 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 131’ 98’

140’ TOWER 14.8 OR 11.8 14.4 172’ 149’

65’ 32’

129’

1/4” EHS (665#) 3/16” EHS (399#)

116’ 112’

P/N: 45G110R140

141’ 106’

150’ TOWER 14.5 OR 11.7 14.0 185’ 160’

72’ 35’

140’

1/4” EHS (665#) 3/16” EHS (399#)

125’ 120’

P/N: 45G110R150

151’ 113’

160’ TOWER 14.2 OR 11.5 13.8 198’ 171’

76’ 38’

149’

1/4” EHS (665#) 3/16” EHS (399#)

134’ 128’

P/N: 45G110R160

161’ 128’

170’ TOWER 14.0 OR 11.4 13.6 211’

96’

187’ 166’

64’

150’

32’

140’

1/4” EHS (605#) 3/16” EHS (399#)

136’

P/N: 45G110R170

172’ 135’

180’ TOWER 13.8 OR 11.2 13.2 224’

99’

197’ 175’

66’

158’

33’

148’

5/16” EHS (1,120#) 3/16” EHS (399#)

144’

P/N: 45G110R180

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45G

45AG2

BPC45G

13

1

1

GA45GD BASEFDNS ANCHOR 4

CB1G AB2

140’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 140

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1275’

18

550’

6

18

6

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

14

1

1

3

1

3

GA45GD BASEFDNS ANCHOR 4

CB1G AB2

150’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 150

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1375’

18

600’

6

18

6

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

15

1

1

3

1

3

GA45GD BASEFDNS ANCHOR 4

CB2G AB2

160’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 160

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1450’

18

650’

6

18

6

12

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

16

1

1

3

1

3

GA45GD BASEFDNS ANCHOR 5

170’ ROHN 45G

CB2G AB3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 170

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 2050’

6

24

675’

24

6

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25

15

3/4x12PP TBSAFETY

3

3

1

3

45G

45GL2*

BPC45G

17

1

1

3

1

GA45GD APL45G BASEFDNS ANCHOR 5

CB2G AB3

1

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 180

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 2175’

6

24

725’

24

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

15

6

180’ ROHN 45G

3/4x12PP TBSAFETY 1

3

* 45GL2 Lug section required for 5/16” guy Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

57


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 182’ 145’ 109’

190’ TOWER 13.6 OR 11.1 13.0 237’ 210’ 187’

73’

169’

36’

156’

5/16” EHS (1,120#) 3/16” EHS (399#)

152’

P/N: 45G110R190

192’

200’ TOWER 13.4 OR 11.0 10.6 250’

155’ 115’

223’ 197’

75’

177’

35’

164’

5/16” EHS (1,120#) 3/16” EHS (399#)

160’

P/N: 45G110R200

202’ 167’ 133’ 99’ 65’ 33’

210’ TOWER 13.2 OR 10.9 10.4 263’ 237’ 5/16” EHS (1,120#) 214’ 3/16” EHS (399#) 195’ 85’ 64’ 55’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

45G

45GL2*

BPC45G

18

1

1

2300’

212’ 175’ 139’ 105’ 69’ 35’

10.2 276’ 248’ 5/16” EHS (1,120#) 224’ 3/16” EHS (399#) 205’ 1/4” EHS (665#) 91’ 69’ 60’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

176’

P/N: 45G110R220

ANCHORS & GROUNDING INCLUDED

CB2G AB3

1

6

24

725’

24

3/4x12PP TBSAFETY

3

3

1

3

45G

45GL2*

BPC45G

19

1

1

3

1

GA45GD APL45G BASEFDNS ANCHOR 5

CB2G AB3

1

6

24

800’

24

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

45G

1

3

3

15

6

3/4x12PP TBSAFETY 1

3

INNER OUTER BPC45G 45GL2* APL45G GA45GD BASE ANCHOR ANCHOR

20

1

1

1

6

CB3G AB2

3/16EHS

142265

BG2142

BG2146

5/16THH

2550’

850’

30

6

30

7/16THH

1/2TBE&J

6

6

5/8TBE&J TBSAFETY 12

3

3

210’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 210

1

6

CPC1/1.25

3

3

2

AB3

3/4x12PP

GAC5655TOP GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

45G

3

INNER OUTER BPC45G 45GL2* APL45G GA45GD BASE ANCHOR ANCHOR

21

1

1

1

6

CB3G AB2

AB3

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

1875’

800’

900’

24

6

6

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

6

6

6

5/8TBE&J TBSAFETY 12

GAC5655TOP GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

200’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 200

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 2425’

190’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 190

15

6

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25

P/N: 45G110R210

220’ TOWER 13.0 OR 10.8

5

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J

168’

ANCHORS & GROUNDING INCLUDED

GA45GD APL45G BASEFDNS ANCHOR

3

2

3

3

220’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 220

6 CPC1/1.25 3/4X12PP 3

1

* 45GL2 Lug section required for 5/16” guy

58

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D D E S I G N - 4 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 222’ 185’ 155’ 125’ 95’ 65’ 33’

230’ TOWER 12.8 OR 10.7 10.0 288’ 261’ 5/16” EHS (1,120#) 241’ 3/16” EHS (399#) 222’ 1/4” EHS 124’ (665#) 103’ 87’ 80’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

45G BPC45G APL45G GA45GD 22

195’ 159’ 125’ 95’ 65’ 35’

240’ TOWER 12.7 OR 10.6 10.0 301’ 274’ 5/16” EHS (1,120#) 249’ 3/16” EHS (399#) 229’ 1/4” EHS 124’ (665#) 103’ 87’ 80’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

192’

P/N: 45G110R240

ANCHORS & GROUNDING INCLUDED

7

1

CB3G AB2

AB3

1/4EHS

142265

BG2142

BG2144

BG2146

2475’

850’

925’

30

6

6

5/16THH

3/8THH

7/16THH

30

6

6

P/N: 45G110R230

232’

1

INNER OUTER BASE ANCHOR ANCHOR

3/16EHS

184’

ANCHORS & GROUNDING INCLUDED

1

45GL2*

1/2TBE&J 5/8TBE&J TBSAFETY 9

12

3

2

45G BPC45G APL45G GA45GD 23

1

1

3 45GL2*

7

1

3

3

CB3G AB2

142265

BG2142

BG2144

BG2146

2525’

875’

975’

30

6

6

5/16THH

3/8THH

7/16THH

30

6

6

1/2TBE&J 5/8TBE&J TBSAFETY 12

2

3

3

240’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G110R 240

6

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX CPC.5/.75 CPC1/1.25 3

1

AB3

1/4EHS

3

3/4x12PP

INNER OUTER BASE ANCHOR ANCHOR

3/16EHS

9

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G110R 230

6

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX CPC.5/.75 CPC1/1.25 3

230’ ROHN 45G

3

3/4x12PP 1

* 45GL2 Lug section required for 5/16” guy

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

59


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 40’ TOWER 15.3 OR 11.1

35’

TOWER PARTS INCLUDED

13.0 47’ 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

32’

P/N: 45G130R040 50’ TOWER 14.3 OR 10.6

45’

TOWER PARTS INCLUDED

12.0 60’ 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

40’

P/N: 45G130R050

55’

60’ TOWER 13.6 OR 10.2 11.6

54’

1/4” EHS (665#) 3/16” EHS (399#)

48’

P/N: 45G130R060

65’

70’ TOWER 13.0 OR 9.9 11.0

63’

1/4” EHS (665#) 3/16” EHS (399#)

56’

P/N: 45G130R070

75’

80’ TOWER 12.5 OR 9.6 10.6

73’

1/4” EHS (665#) 3/16” EHS (399#)

64’

P/N: 45G130R080

60

ANCHORS & GROUNDING INCLUDED

GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

99’ 35’

GUYS & CONNECTIONS INCLUDED

TOWER PARTS INCLUDED

86’ 29’

ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

73’ 25’

ANCHORS & GROUNDING INCLUDED

GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45G

45AG2

BPC45G

3

1

1

1/4EHS

BG2144

3/8THH

150’

6

6

GA45GD BASEFDNS ANCHOR 1

1

3

45G

45AG2

BPC45G

4

1

1

1/4EHS

BG2144

3/8THH

200’

6

6

3

3 3/4x12PP 1

3

GA45GD BASEFDNS ANCHOR 1

1

3

45G

45AG2

BPC45G

5

1

1

50’ ROHN 45G

CB1G AB2

Al l par ts shown i n ta b l e are i nc l uded w hen order i ng Pa r t No: 45G130R 050

1/2TBE&J TBSAFETY 3

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

Al l par ts shown i n ta b l e are i nc l uded w hen order i ng Pa r t No: 45G130R 040

1/2TBE&J TBSAFETY

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

40’ ROHN 45G

CB1G AB2

3/4x12PP 1

3

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

60’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G130R 060

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 175’

6

250’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

6

1

1

6 3/4x12PP

TBSAFETY

1

3

3

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

70’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G130R 070

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 225’

6

275’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45G

45AG2

BPC45G

7

1

1

3

6 3/4x12PP

TBSAFETY

1

3

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

80’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G130R 080

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 250’

6

325’

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

3

6 3/4x12PP

TBSAFETY

1

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D D E S I G N - 4 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 85’

90’ TOWER 12.1 OR 9.4

TOWER PARTS INCLUDED

10.0 111’

39’ 82’

1/4” EHS (665#) 3/16” EHS (399#)

72’

P/N: 45G130R090

95’

100’ TOWER 11.7 OR 9.2 9.6

31’

101’

1/4” EHS (665#) 3/16” EHS (399#)

86’

80’

P/N: 45G130R100

105’

110’ TOWER 11.4 OR 9.0 9.0

34’

111’

1/4” EHS (665#) 3/16” EHS (399#)

94’

88’

P/N: 45G130R110

115’

120’ TOWER 11.1 OR 8.8 8.6

35’

122’

5/16”EHS (1,120#) 3/16” EHS (399#)

102’

96’

P/N: 45G130R120

125’

130’ TOWER 10.9 OR 8.6 8.2 163’

78’ 35’

130’ 110’

ANCHORS & GROUNDING INCLUDED

GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

150’ 75’

GUYS & CONNECTIONS INCLUDED

TOWER PARTS INCLUDED

137’ 67’

ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

124’ 61’

GUYS & CONNECTIONS INCLUDED

GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

5/16”EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

104’

P/N: 45G130R130

ANCHORS & GROUNDING INCLUDED

45G

45AG2

BPC45G

8

1

1

GA45GD BASEFDNS ANCHOR 2

CB1G AB2

90’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G130R 090

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 275’

6

375’

6

6

6

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

9

1

1

1

3

3

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

100’ ROHN 45G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G130R 100

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 600’

12

400’

6

12

6

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

1

3

45G

45AG2

BPC45G

10

1

1

3

1

3

GA45GD BASEFDNS ANCHOR 3

CB1G AB2

110’ ROHN 45G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G130R 110

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 675’

12

450’

6

12

6

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP TBSAFETY 3

3

1

3

3

1

45G

45GL5*

BPC45G

GA45GD

APL45G

11

1

1

3

1

FDNS

BASE ANCHOR

CB1G AB2

120’ ROHN 45G Al l par ts shown i n

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 1/2TBE&J 5/8TBE&J tabl e are i nc l ud ed 725’

12

500’

6

12

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75

6

3

3/4x12PP

TBSAFETY

1

3

when ord er i ng Par t No: 45G130R 120

3

1

3

3

45G

45GL5*

BPC45G

GA45GD

12

1

1

3

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

130’ ROHN 45G

350’

425’

525’

6

6

6

5/16THH

3/8THH

7/16THH

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 45G130R 130

6

6

6

APL45G BASEFDNS ANCHOR 1

CB2G AB3

5/8TBE&J TBSAFETY 9

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3/4x12PP 3

1

3

3

1

* 45GL5 Lug section required for 5/16” guy Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

61


G

GUYED TOWERS - 45G

S TA N D A R D D E S I G N - 4 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 135’ 98’ 65’ 32’

140’ TOWER 10.6 OR 8.5 7.8 175’

5/16” EHS 149’ (1,120#) 1/4” EHS (665#) 129’ 3/16” EHS (399#) 116’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

112’

P/N: 45G130R140

ANCHORS & GROUNDING INCLUDED

145’ 106’ 72’ 35’

150’ TOWER 10.4 OR 8.4 7.4 188’

5/16” EHS 160’ (1,120#) 1/4” EHS (665#) 140’ 3/16” EHS (399#) 125’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

120’

P/N: 45G130R150

ANCHORS & GROUNDING INCLUDED

FDNS

45G

45GL5*

BPC45G

GA45GD

APL45G

13

1

1

4

1

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

140’ ROHN 45G

800’

475’

575’

12

6

6

5/16THH

3/8THH

7/16THH

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G130R 140

12

6

6

BASE ANCHOR

CB2G AB3

5/8TBE&J TBSAFETY 12

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3/4x12PP 3

1

3

3

1

45G

45GL5*

BPC45G

GA45GD

APL45G

14

1

1

4

1

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

150’ ROHN 45G

850’

525’

600’

12

6

6

5/16THH

3/8THH

7/16THH

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45G130R 150

12

6

6

5/8TBE&J TBSAFETY 12

FDNS

BASE ANCHOR

CB2G AB3

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3/4x12PP 3

1

3

3

1

* 45GL5 Lug section required for 5/16” guy

62

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 45G

PA R T S & A CC E S S O R I E S 2.38” O.D. 2.07“ I.D.

1’ - 6” 1’ - 0”

2.00“ O.D. 1.87” I.D.

1.66“ O.D. 1.38” I.D. 1.25” N.P.T.

1’ - 0”

9’ - 0” 2’ - 0”

Set Screw

2’ - 0”

TOP SECTION 45AG

2.25” O.D. 2.08“ I.D.

2’ - 0” 9’ - 0”

Set Screw

9’ - 6” 2’ - 0”

9’ - 0”

1’ - 0”

TOP SECTION 45AG2

TOP SECTION 45AG1

TOP SECTION 45AG3

Set Screw

1’ - 8” 1’ - 1” 8’ - 1“

7’ - 8”

8”

2.75” O.D. 2.58“ I.D.

1’-3 3/4”

BEARING PLATE BPL45G

TOP SECTION 45AG5

TOP SECTION 45AG4 TOP PLATE HOLE PATTERN IS THE SAME AS BPL45G.

TOP PLATE APL45G

CONVERTS STANDARD SECTION TO A TOP SECTION. HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARINGS.

FOR MOUNTING BEACON OR LIGHTNING ROD.

ACCESSORY SHELF AS455G

LIGHTNING ROD LRCL

TOP MOUNT 45TDMKD - NO MAST 45TDM2S3KD - 2 3/8” O.D. MAST 45TDM25S3KD - 2 7/8” O.D. MAST 45TDM3S3KD - 3 1/2” O.D. MAST 45TDM35S3KD - 4” O.D. MAST 45TDM4S3KD - 4 1/2” O.D. MAST MOUNTING TUBE PROVIDED IS 7’ LONG.

FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

5’ COPPER CLAD MOUNTS TO APL45G.

63


G

GUYED TOWERS - 45G

PA R T S & A CC E S S O R I E S

5/8” x 12”

CONCRETE BASE PLATE BPC45G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. CONCRETE BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

HINGED BASE PLATE BPH45G*

PIER PIN 3/4X12PP FOR USE WITH BPC45G EMBEDDED IN CONCRETE. PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.

FOR USE WITH 5/8X12BB BASE BOLTS (ORDERED SEPARATELY). HINGED TO ALLOW TOWER TO BE ROTATED UP FROM BASE DURING INSTALLATION.

BASE BOLT 5/8X12BB FOR USE WITH BPH45G (6) REQUIRED, ORDERED SEPARATELY.

HINGED BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

Adjustable 2.5’ - 3.0’

TAPERED BASE 45TG*

5’ SHORT BASE SB45G

CAN BE USED WITH A4197L BASE INSULATOR OR WITH 3/4X12PP, ORDERED SEPARATELY.

FOR EMBEDMENT IN CONCRETE.

FLAT ROOF MOUNT FR45G*

SIDE ARM BRACKET SA253UA

BOLTS DIRECTLY TO FLAT ROOF SURFACE.

MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.

HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO

DISH MOUNT VY4311A2 - 2 3/8” O.D. VY4311A - 4 1/2” O.D. MAST TUBE PROVIDED IS 5’ LONG.

FACE MOUNT DM45G2 - 2 3/8” O.D. 5’ LONG DM454 - 4 1/2” O.D. 5’ LONG

ADJUSTABLE TO POSITION TOWER 18” - 36” FROM WALL.

TORQUE ARM STABILIZER ASSEMBLY TA45 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

64

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

PA R T S & A CC E S S O R I E S

TORQUE BAR TB45D

OPTIONAL, FOR USE WITH GA45GD. REQUIRES (1) 3/8” SHACKLE FOR EACH BAR.

GUY BRACKET GA45GD MOUNTS TO TOWER AT ANY HORIZONTAL BRACE.

TB3 - SUPPORTS UP TO 2” O.D. MAST. TB4 - SUPPORTS UP TO 3” O.D. MAST.

TOWER BUSHING TB50 - 1-1/4” I.D. X 2” O.D. TB75 - 1-1/2” I.D. X 2” O.D.

MOUNTS TO BPL45G AND 45AG4.

FOR USE ON 45AG TOP SECTION

THRUST BEARING

WARNING WARNING WARNING THIS ITEM IS NOT INTENDED FOR THE LIFTING OF PERSONNEL See safety precaution literature

ANTI-CLIMB PANELS VW913A THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.

WORK PLATFORM WP45G

SAFETY RING SR245

SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

ERECTION FIXTURE EF2545 - 2 1/2” SHEAVE WITH 3/8“ I.D. GROOVE. NOTE: ERECTION FIXTURES ARE FOR LIFTING ONE 10’ SECTION AT A TIME AND ARE NOT INTENDED FOR THE LIFTING OF PERSONNEL.

SAFETY CABLE SYSTEM ORDERING INFORMATION

CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS

TTFBH-C/P

PROFESSIONAL HARNESS

SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC

TOWER HEIGHT 50’ 100’ 150’ 200’ 250’ 300’ 350’

PART NUMBER TT0504555 TT1004555 TT1504555 TT2004555 TT2504555 TT3004555 TT3504555

SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

65


G

GUYED TOWERS - 45G

A N C H O R I N F O R M AT I O N 81”

12” 3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4” 4” x 4” x 3/8” angle

2” 11/16”

GAC3455TOP

120”

12” 1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4” 5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP

REV G BASE GROUNDING BGK3GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp

Ground Wire Clamp

Ground Wire

Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed at 120o separation at 20’ spacing.

66

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required

o

Top and bottom horizontal bars equally spaced

A B

C

D

Refer to page 68 for anchor rod installation angles.

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

67


G

GUYED TOWERS - 45G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

Anchor Rod Angle

45G | 90MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 210’ 220’ 230’ 240’ 250’ 260’ 270’ 280’ 290’ 300’

68

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 45 GAC3455TOP 46 GAC3455TOP 43 GAC3455TOP 43 GAC3455TOP 41 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 40 GAC3455TOP 39 GAC3455TOP 40 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 37 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 36 GAC3455TOP 36 GAC3455TOP 40 GAC3455TOP 44 GAC3455TOP 40 GAC3455TOP 44 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 41 GAC3455TOP 40 GAC3455TOP 43 GAC3455TOP 40 GAC3455TOP 42 GAC3455TOP 38 GAC3455TOP 43 GAC3455TOP 38 GAC3455TOP 43 GAC3455TOP 38 GAC3455TOP 44 GAC3455TOP 38 GAC3455TOP 43

Ground Line

45G | 110MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 210’ 220’ 230’ 240’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 45 GAC3455TOP 46 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38 GAC5655TOP 37 GAC5655TOP 37 GAC5655TOP 37 GAC5655TOP 37 GAC3455TOP 41 GAC5655TOP 42 GAC3455TOP 41 GAC5655TOP 42 GAC3455TOP 38 GAC5655TOP 43 GAC3455TOP 39 GAC5655TOP 43

45G | 130MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’

Rod Rod Number Angle GAC3455TOP 48 GAC3455TOP 48 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 38 GAC3455TOP 38 GAC3455TOP 38 GAC5655TOP 38 GAC5655TOP 37 GAC5655TOP 37

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45G

G

S TA N D A R D B A S E P I E R S Pier Pin 4” Projection Grade

6”

(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps

No. 4 Circular ties, 3” Max. O.C. with 24” laps

B

Vertical bars equally spaced

ELEVATION VIEW

A

Alternate Square Pier

No. 4 Circular ties, 3” O.C. with 24” laps

CL

A

Vertical bars equally spaced

CL

PLAN VIEW

Base

A

B

Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier

CB1G* 2’ - 6” 4’ - 0”

1.0

(8) #7

CB2G

3’ - 0” 4’ - 0”

1.2

(10) #7

CB3G

3’ - 6” 4’ - 0”

1.6

(12) #7

* Square pier option must be used for CB1G. Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

69


G

GUYED TOWERS - 45GSR

S TA N D A R D 4 5 G S R G U Y E D T O W E R

ROHN 45GSR The first. The original.

45GSR GENERAL USE The 45GSR maintains the utility of the 45G and adds the strength of solid round steel legs. The 45GSR has a strong 4 bolt flange connection, giving connection joints superior strength over typical 1 bolt flange connection systems. The 45GSR is available in heights up to 340’.

FEATURES • Completely hot-dip galvanized after fabrication • Built on a 16 3/4” equilateral triangle design • Heavy solid steel round legs joined by Zig-Zag®

cross members

• Each section contains all required nuts and bolts

shipped with section

• Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 92 for ordering information.

70

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

G

S TA N D A R D 4 5 G S R G U Y E D T O W E R SECTIONS 9 21/32”

QUICK REFERENCE

14 1/2”

PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION

PAGE 92 PAGE 93 PAGES 93-97

16 3/4”

Optional Waveguide Brackets (KY2041A)

1 1/4” O.D. Solid Round 7/16” O.D. Solid Bracing

1 1/4” O.D. Solid Round 7/16” O.D. Solid Bracing

Optional double braced sections are available upon request.

4.3’ 45GSR SHORT BASE 45GSRSB TO BE EMBEDDED IN CONCRETE.

STANDARD SECTION 45GSR10 - 10’ Section 45GSR20 - 20’ Section

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

71


G

GUYED TOWERS - 45GSR

BUYERS GUIDE S TA N D A R D D E S I G N S - 4 5 G S R 9 0 M P H R E V. G [ 3 S E C O N D G U S T ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 35’

73.8

101.8

EPA (SQ. FT.) For Exposure C, Revision G 47’ 1/4” EHS (665#)

Guy Initial Tension

P/N 45GSR90R040 32’

P/N 45GSR90R040

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 45GSR tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 7/8” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 93-97. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

72

Phone (309) 566-3000 • Fax (309) 566-3079• www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 9 0 M P H R E V. G 35’

40’ TOWER 95.0 OR 73.8 47’ 1/4” EHS (665#)

32’

P/N: 45GSR90R040

45’

50’ TOWER 95.0 OR 70.0 60’ 1/4” EHS (665#)

40’

P/N: 45GSR90R050

55’

60’ TOWER 90.4 OR 66.7 73’ 1/4” EHS (665#)

48’

P/N: 45GSR90R060

65’

70’ TOWER 86.5 OR 64.9 86’ 1/4” EHS (665#)

35’

66’

56’

P/N: 45GSR90R070

75’

80’ TOWER 82.6 OR 62.9 99’ 1/4” EHS (665#)

35’

73’

64’

P/N: 45GSR90R080

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45GSR20

45GSRSB

GA45GD

2

1

1

1/4EHS

BG2144

3/8THH

150’

6

6

G

45GSR

SOLID ROD

FDNS

BASE ANCHOR

FB1G AB2 1/2TBE&J TBSAFETY 3

3

40’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 040

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

2

1

1

1/4EHS

BG2144

3/8THH

200’

6

6

3 FDNS

GA45GD 1

BASE ANCHOR

FB1G AB2

1/2TBE&J TBSAFETY 3

3

50’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 90R 050

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

3

1

1

1/4EHS

BG2144

3/8THH

250’

6

6

3 FDNS

BASE ANCHOR

FB1G AB2 1/2TBE&J TBSAFETY 3

3

60’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 060

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

3

1

1

1/4EHS

BG2144

3/8THH

500’

12

12

3 FDNS

GA45GD 2

BASE ANCHOR

FB1G AB2

1/2TBE&J TBSAFETY 6

3

70’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 90R 070

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

4

1

2

1/4EHS

BG2144

3/8THH

550’

12

12

3 FDNS

BASE ANCHOR

FB1G AB2 1/2TBE&J TBSAFETY 6

3

80’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 080

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

73


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 9 0 M P H R E V. G 90’ TOWER 80.3 OR 60.4

85’

111’ 1/4” EHS (665#) 45’

85’

72’

P/N: 45GSR90R090 100’ TOWER 78.0 OR 58.4

95’

124’ 1/4” EHS (665#) 55’

97’

80’

P/N: 45GSR90R100 110’ TOWER 75.4 OR 56.6

105’

137’ 1/4” EHS (665#)

65’ 109’ 35’

95’ 88’

P/N: 45GSR90R110

115’

120’ TOWER 73.5 OR 54.2 150’ 1/4” EHS (665#)

75’ 122’ 35’

102’ 96’

P/N: 45GSR90R120 130’ TOWER 65.0 OR 49.8

118’

157’

GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED

5/16” EHS (1,120#)

85’ 134’ 45’

TOWER PARTS INCLUDED

1/4” EHS (665#)

113’

GUYS & CONNECTIONS INCLUDED

104’

P/N: 45GSR90R130

ANCHORS & GROUNDING INCLUDED

74

45GSR20

45GSR10 45GSRSB

4

1

1

1/4EHS

BG2144

3/8THH

625’

12

12

FDNS

GA45GD 2

BASE ANCHOR

45GSR

SOLID ROD

FB1G AB2

1/2TBE&J TBSAFETY 3

6

90’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 90R 090

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

5

1

2

1/4EHS

BG2144

3/8THH

725’

12

12

3 FDNS

BASE ANCHOR

FB1G AB2 1/2TBE&J TBSAFETY 3

6

100’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 100

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3 45GSR20

1

3

45GSR10 45GSRSB

5

1

1

1/4EHS

BG2144

3/8THH

1100’

18

18

3 FDNS

GA45GD 3

BASE ANCHOR

FB1G AB2

1/2TBE&J TBSAFETY 3

9

110’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 90R 110

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

6

1

3

1/4EHS

BG2144

3/8THH

1200’

18

18

3 FDNS

BASE ANCHOR

FB1G AB2 1/2TBE&J TBSAFETY 9

3

120’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Pa r t No: 45GS R 90R 120

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3 45GSR20

1

3

45GSR10 45GSRSB

3 GA45GD

FDNS

BASE ANCHOR

6

1

1

3

1/4EHS

142265

BG2144

BG2146

130’ ROHN 45GSR

6

Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 130

800’

500’

3/8THH

7/16THH

12

6

12

FB1G AB2

5/8TBE&J 1/2TBE&J 3

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 TBSAFETY 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 9 0 M P H R E V. G 128’

140’ TOWER 63.5 OR 48.9 170’ 5/16” EHS (1,120#)

95’ 147’ 55’

TOWER PARTS INCLUDED

1/4” EHS (665#)

125’

GUYS& CONNECTIONS INCLUDED

112’

P/N: 45GSR90R140

ANCHORS & GROUNDING INCLUDED

138’ 105’

150’ TOWER 62.2 OR 48.2 183’ 159’

65’ 35’

136’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

125’

GUYS & CONNECTIONS INCLUDED

120’

P/N: 45GSR90R150

ANCHORS & GROUNDING INCLUDED

148’ 115’

160’ TOWER 60.4 OR 47.0 196’ 172’

75’ 35’

148’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

133’

GUYS & CONNECTIONS INCLUDED

128’

P/N: 45GSR90R160

ANCHORS & GROUNDING INCLUDED

158’ 125’

170’ TOWER 59.9 OR 46.4 208’ 185’

85’ 45’

160’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

143’

GUYS & CONNECTIONS INCLUDED

136’

P/N: 45GSR90R170

ANCHORS & GROUNDING INCLUDED

FDNS

45GSR20

45GSRSB

GA45GD

7

1

3

1/4EHS

142265

BG2144

BG2146

875’

550’

12

6

3/8THH

7/16THH

12

6

45GSR

SOLID ROD

BASE ANCHOR

FB1G AB2

140’ ROHN 45GSR Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45GS R 90R 140

5/8TBE&J 1/2TBE&J 3

G

6

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 TBSAFETY 3 45GSR20

1

3

45GSR10 45GSRSB 1

1

4

1/4EHS

142265

BG2144

BG2146

1350’

600’

18

6

7/16THH

18

6

FDNS

GA45GD

7

3/8THH

3

3

BASE ANCHOR

FB1G AB2

150’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 90R 150

5/8TBE&J 1/2TBE&J 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 TBSAFETY 3

1

3

45GSR20

45GSRSB

GA45GD

8

1

4

1/4EHS

142265

BG2144

BG2146

1450’

625’

18

6

3/8THH

7/16THH

18

6

3

3 FDNS

BASE ANCHOR

FB1G AB2

160’ ROHN 45GSR Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 45GS R 90R 160

5/8TBE&J 1/2TBE&J 3

9

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 TBSAFETY 3 45GSR20

1

3

45GSR10 45GSRSB

3 GA45GD

8

1

1

4

1/4EHS

142265

BG2144

BG2146

1575’

675’

18

6

3/8THH

7/16THH

18

6

3 FDNS

BASE ANCHOR

FB1G AB3

5/8TBE&J TBSAFETY 12

170’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 170

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

75


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 9 0 M P H R E V. G 168’ 135’

180’ TOWER 58.5 OR 45.7 221’ 197’

95’ 55’

173’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

154’

GUYS & CONNECTIONS INCLUDED

144’

P/N: 45GSR90R180

ANCHORS & GROUNDING INCLUDED

178’ 145’ 105’ 65’ 35’

190’ TOWER 57.0 OR 45.2 234’ 210’ 185’ 165’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

156’

GUYS & CONNECTIONS INCLUDED

152’

P/N: 45GSR90R190

ANCHORS & GROUNDING INCLUDED

188’ 155’ 115’ 75’ 35’

200’ TOWER 56.1 OR 44.6 247’

TOWER PARTS INCLUDED

5/16” EHS 223’ (1,120#) 197’ 177’

1/4” EHS (665#)

164’

GUYS & CONNECTIONS INCLUDED

160’

P/N: 45GSR90R200

ANCHORS & GROUNDING INCLUDED

208’ 175’ 135’ 95’ 55’

220’ TOWER 54.2 OR 43.5 272’ 248’ 222’ 200’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

184’

GUYS & CONNECTIONS INCLUDED

176’

P/N: 45GSR90R220

ANCHORS & GROUNDING INCLUDED

76

FDNS

45GSR20

45GSRSB

GA45GD

9

1

4

1/4EHS

142265

BG2144

BG2146

1675’

725’

18

6

3/8THH

7/16THH

18

6

FB1G AB3

180’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l uded w h e n order i ng Pa r t No : 45GS R 90R 180

5/8TBE&J TBSAFETY 12

45GSR

SOLID ROD

BASE ANCHOR

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3 45GSR20

1

3

45GSR10 45GSRSB

3 GA45GD

9

1

1

5

1/4EHS

142265

BG2144

BG2146

2300’

750’

24

6

3/8THH

7/16THH

24

6

FDNS

BASE ANCHOR

FB1G AB3

190’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l uded w h e n order i ng Pa r t No : 45GS R 90R 190

5/8TBE&J TBSAFETY 15

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

45GSR20

45GSRSB

GA45GD

APL4A

10

1

5

1

1/4EHS

142265

BG2144

BG2146

2425’

800’

24

6

3/8THH

7/16THH

24

6

FDNS

BASE ANCHOR

FB1G AB3

200’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l uded w h e n order i ng Pa r t No : 45GS R 90R 200

5/8TBE&J TBSAFETY 15

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

45GSR20

45GSRSB

GA45GD

APL4A

11

1

5

1

1/4EHS

142265

BG2144

BG2146

2725’

875’

24

6

3/8THH

7/16THH

24

6

5/8TBE&J TBSAFETY 15

FDNS

BASE ANCHOR

FB1G AB3

220’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l uded w h e n order i ng Pa r t No: 45GS R 90R 220

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 9 0 M P H R E V. G 228’ 195’ 155’ 115’ 75’ 35’

240’ TOWER 52.5 OR 42.6 298’ 274’ 247’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

150’ 122’ 102’ 96’

GUYS & CONNECTIONS INCLUDED

192’

P/N: 45GSR90R240

ANCHORS & GROUNDING INCLUDED

248’ 215’ 175’ 135’

260’ TOWER 51.1 OR 41.8 324’ 299’ 272’

95’

175’

55’

147’ 125’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

112’ 208’

P/N: 45GSR90R260

ANCHORS & GROUNDING INCLUDED

268’ 235’ 195’ 155’ 115’ 75’ 35’

280’ TOWER 50.0 OR 40.9 349’ 325’ 297’ 272’ 150’ 122’ 102’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

96’

GUYS & CONNECTIONS INCLUDED

224’

P/N: 45GSR90R280

ANCHORS & GROUNDING INCLUDED

288’ 255’ 215’ 175’ 135’ 95’ 55’

300’ TOWER 48.9 OR 40.1 375’ 350’ 322’ 297’

5/16” EHS (1,120#) 1/4” EHS (665#)

175’ 147’ 125’

TOWER PARTS INCLUDED

112’

GUYS & CONNECTIONS INCLUDED

240’

P/N: 45GSR90R300

ANCHORS & GROUNDING INCLUDED

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

12

1

6

1

FB1G AB2

1/4EHS

142265

BG2144

BG2146

2850’

950’

30

6

3/8THH

7/16THH

30

6

AB2

240’ ROHN 45GSR Al l par ts shown i n ta b l e are i nc l uded w hen order i ng Pa r t No: 45GS R 90R 240

5/8TBE&J 1/2TBE&J 3

45GSR

SOLID ROD

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 TBSAFETY 2

6

3

6

6

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

13

1

6

1

FB1G AB2

1/4EHS

142265

BG2144

BG2146

3250’

1050’

30

6

3/8THH

7/16THH

30

6

AB2

260’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l uded when order i ng Pa r t No: 45GS R 90R 260

5/8TBE&J 1/2TBE&J 3

15

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 TBSAFETY 2

6

3

6

6

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

14

1

7

1

FB1G AB2

AB3

1/4EHS

142265

BG2144

BG2146

3/8THH

4050’

1125’

36

6

36

7/16THH

5/8TBE&J

6

12

1/2TBE&J CPC.5/.75 CPC1/1.25 9

280’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l ud ed when ord er i ng Pa r t No: 45GS R 90R 280

3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

2

3

6

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

15

1

7

1

FB1G AB2

AB3

1/4EHS

142265

BG2144

BG2146

3/8THH

4525’

1200’

36

6

36

7/16THH

5/8TBE&J

6

12

1/2TBE&J CPC.5/.75 CPC1/1.25 9

3

300’ ROHN 45GSR All par ts shown i n ta bl e are i nc l ud ed when ord er i ng Pa r t No: 45GS R 90R 300

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

3

2

3

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

77


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 9 0 M P H R E V. G 308’ 275’ 235’ 195’ 155’ 115’ 75’ 35’

320’ TOWER 47.7 OR 39.5 400’ 376’ 348’ 322’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

201’ 172’ 148’ 133’ 128’

GUYS & CONNECTIONS INCLUDED

256’

P/N: 45GSR90R320

ANCHORS & GROUNDING INCLUDED

328’ 295’ 255’ 215’ 175’ 135’ 95’ 55’

340’ TOWER 46.8 OR 38.9 426’ 401’ 373’ 347’ 227’ 197’ 173’ 154’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

144’ 272’

P/N: 45GSR90R340

ANCHORS & GROUNDING INCLUDED

78

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

16

1

8

1

FB1G AB2

AB3

1/4EHS

142265

BG2144

BG2146

3/8THH

5450’

1275’

42

6

42

7/16THH

5/8TBE&J

6

12

1/2TBE&J CPC.5/.75 CPC1/1.25 12

45GSR

SOLID ROD

320’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l ud ed w hen order i ng Pa r t No: 45GS R 90R 320

3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

2

3

6

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

17

8

1

1

FB1G AB2

AB3

1/4EHS

142265

BG2144

BG2146

3/8THH

5975’

1375’

42

6

42

7/16THH

5/8TBE&J

6

12

1/2TBE&J CPC.5/.75 CPC1/1.25 12

3

340’ ROHN 45GSR Al l par ts shown i n ta bl e are i nc l ud ed w hen order i ng Pa r t No: 45GS R 90R 340

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

3

2

3

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 1 0 M P H R E V. G 35’

40’ TOWER 66.9 OR 48.2 47’ 1/4” EHS (665#)

32’

P/N: 45GSR110R040

45’

50’ TOWER 63.1 OR 46.0 60’ 1/4” EHS (665#)

40’

P/N: 45GSR110R050

55’

60’ TOWER 57.5 OR 38.3 73’ 1/4” EHS (665#)

48’

P/N: 45GSR110R060

65’

70’ TOWER 57.2 OR 42.4 86’ 1/4” EHS (665#)

35’

66’

56’

P/N: 45GSR110R070

75’

80’ TOWER 52.7 OR 35.5 99’ 1/4” EHS (665#)

35’

73’

64’

P/N: 45GSR110R080

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

45GSR20

45GSRSB

GA45GD

2

1

1

1/4EHS

BG2144

3/8THH

150’

6

6

G

45GSR

SOLID ROD

FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J TBSAFETY 3

3

40’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 040

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

2

1

1

1/4EHS

BG2144

3/8THH

200’

6

6

3 FDNS

GA45GD 1

BASE ANCHOR

FB2G AB2

1/2TBE&J TBSAFETY 3

3

50’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 110R 050

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

3

1

1

1/4EHS

BG2144

3/8THH

250’

6

6

3 FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J TBSAFETY 3

3

60’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 060

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

3

1

1

1/4EHS

BG2144

3/8THH

500’

12

12

3 FDNS

GA45GD 2

BASE ANCHOR

FB2G AB2

1/2TBE&J TBSAFETY 6

3

70’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 110R 070

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

4

1

2

1/4EHS

BG2144

3/8THH

550’

12

12

3 FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J TBSAFETY 6

3

80’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 080

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

79


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 1 0 M P H R E V. G 85’

90’ TOWER 49.4 OR 33.0

TOWER PARTS INCLUDED

111’ 1/4” EHS (665#) 45’

GUYS & CONNECTIONS INCLUDED

85’

72’

P/N: 45GSR110R090

88’

100’ TOWER 44.5 OR 32.6

ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

119’ 5/16”EHS (1,120#) 55’

97’

1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

80’

P/N: 45GSR110R100

ANCHORS & GROUNDING INCLUDED

98’

110’ TOWER 43.0 OR 31.7 132’ 5/16”EHS (1,120#)

65’ 109’ 35’

TOWER PARTS INCLUDED

1/4” EHS (665#)

95’

GUY WIRE & CONNECTION INCLUDED

88’

P/N: 45GSR110R110

ANCHORS & GROUNDING INCLUDED

108’

120’ TOWER 41.4 OR 30.7 144’ 5/16”EHS (1,120#)

75’ 122’ 35’

TOWER PARTS INCLUDED

1/4” EHS (665#)

102’

GUYS & CONNECTIONS INCLUDED

96’

P/N: 45GSR110R120

ANCHORS & GROUNDING INCLUDED

80

45GSR20

45GSR10 45GSRSB

4

1

1

1/4EHS

BG2144

3/8THH

625’

12

12

FDNS

GA45GD 2

BASE ANCHOR

45GSR

SOLID ROD

FB2G AB2

1/2TBE&J TBSAFETY 3

6

90’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 110R 090

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

5

1

2

1/4EHS

142265

3/8THH

325’

400’

6

3

7/16THH

BG2144

BG2146

TBSAFETY

6

6

6

3

3 FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J 5/8TBE&J 3

100’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Pa r t No: 45GS R 110R 100

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

45GSR20

45GSR10

5

1

1

1/4EHS

142265

3/8THH

650’

425’

12

6

7/16THH

BG2144

BG2146

TBSAFETY

6

12

6

3

3

3

FDNS 45GSRSB GA45GD BASE ANCHOR 3

FB2G AB2

1/2TBE&J 5/8TBE&J 3

110’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Pa r t No: 45GS R 110R 110

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

6

1

3

1/4EHS

142265

3/8THH

725’

475’

12

6

7/16THH

BG2144

BG2146

TBSAFETY

6

12

6

3

3 FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J 5/8TBE&J 3

120’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Pa r t No: 45GS R 110R 120

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 1 0 M P H R E V. G 118’

130’ TOWER 40.5 OR 29.9 157’ 5/16” EHS (1,120#)

85’ 134’ 45’

TOWER PARTS INCLUDED

1/4” EHS (665#)

113’

GUYS & CONNECTIONS INCLUDED

104’

P/N: 45GSR110R130

ANCHORS & GROUNDING INCLUDED

128’

140’ TOWER 39.4 OR 29.3 170’ 5/16” EHS (1,120#)

95’ 147’ 55’

TOWER PARTS INCLUDED

1/4” EHS (665#)

125’

GUYS & CONNECTIONS INCLUDED

112’

P/N: 45GSR110R140

ANCHORS & GROUNDING INCLUDED

138’ 105’

150’ TOWER 38.3 OR 28.7 183’ 159’

65’ 35’

136’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

125’

GUYS & CONNECTIONS INCLUDED

120’

P/N: 45GSR110R150

ANCHORS & GROUNDING INCLUDED

148’ 115’

160’ TOWER 37.5 OR 28.2 196’ 172’

75’ 35’

148’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

133’

GUYS & CONNECTIONS INCLUDED

128’

P/N: 45GSR110R160

ANCHORS & GROUNDING INCLUDED

FDNS 45GSRSB GA45GD BASE ANCHOR

45GSR20

45GSR10

6

1

1

1/4EHS

142265

3/8THH

800’

500’

12

6

7/16THH

BG2144

BG2146

TBSAFETY

6

12

6

3

3

G

45GSR

SOLID ROD

FB2G AB2

1/2TBE&J 5/8TBE&J 3

130’ ROHN 45GSR All par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 130

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

7

1

3

1/4EHS

142265

3/8THH

875’

550’

12

7/16THH

BG2144

6

12

3 FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J 5/8TBE&J 3

6

140’ ROHN 45GSR All par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 140

BG2146 TBSAFETY 6

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

45GSR20

45GSR10

7

1

1

4

1/4EHS

142265

3/8THH

5/8TBE&J

1350’

600’

18

12

7/16THH

BG2144

6

18

3

3

FDNS 45GSRSB GA45GD BASE ANCHOR FB2G AB3

BG2146 TBSAFETY 6

150’ ROHN 45GSR All par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 110R 150

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

45GSR20

45GSRSB

GA45GD

8

1

4

FB2G AB3

1/4EHS

142265

3/8THH

5/8TBE&J

1450’

625’

18

12

7/16THH

BG2144

BG2146

TBSAFETY

6

18

6

3

3 FDNS

BASE ANCHOR

160’ ROHN 45GSR All par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 160

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

81


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 1 0 M P H R E V. G 158’ 125’

170’ TOWER 36.8 OR 27.8 208’ 185’

85’ 45’

160’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

143’

GUYS & CONNECTIONS INCLUDED

136’

P/N: 45GSR110R170

ANCHORS & GROUNDING INCLUDED

168’ 135’ 95’ 55’

180’ TOWER 35.7 OR 27.3

TOWER PARTS INCLUDED

221’ 5/16” EHS 197’ (1,120#) 173’

1/4” EHS (665#)

154’

GUYS & CONNECTIONS INCLUDED

144’

P/N: 45GSR110R180

ANCHORS & GROUNDING INCLUDED

178’ 145’ 105’ 65’ 35’

190’ TOWER 35.1 OR 26.9 234’ 210’ 185’ 165’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

156’

GUYS & CONNECTIONS INCLUDED

152’

P/N: 45GSR110R190

ANCHORS & GROUNDING INCLUDED

188’ 155’ 115’ 75’ 35’

200’ TOWER 34.6 OR 26.6 247’

TOWER PARTS INCLUDED

5/16” EHS 223’ (1,120#) 197’ 177’

1/4” EHS (665#)

164’

GUYS & CONNECTIONS INCLUDED

160’

P/N: 45GSR110R200

ANCHORS & GROUNDING INCLUDED

82

FDNS 45GSRSB GA45GD BASE ANCHOR

45GSR20

45GSR10

8

1

1

4

1/4EHS

142265

3/8THH

5/8TBE&J

1575’

675’

18

12

7/16THH

BG2144

BG2146

TBSAFETY

6

18

6

3

45GSR

SOLID ROD

FB2G AB3

170’ ROHN 45GSR Al l par ts shown i n tabl e a re i n cl uded when order i ng Pa r t No: 45GS R 110R 170

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

45GSR20

45GSRSB

GA45GD

9

1

4

FB2G AB3

1/4EHS

142265

3/8THH

5/8TBE&J

1675’

725’

18

12

7/16THH

BG2144

BG2146

TBSAFETY

6

18

6

3

3 FDNS

BASE ANCHOR

180’ ROHN 45GSR Al l p ar ts shown i n tabl e a re i n c l uded when order i ng Pa r t No: 45GS R 110R 180

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

45GSR20

45GSR10

9

1

1

5

1/4EHS

142265

3/8THH

5/8TBE&J

2300’

750’

24

15

7/16THH

BG2144

BG2146

TBSAFETY

6

24

6

3

3

3

FDNS 45GSRSB GA45GD BASE ANCHOR FB2G AB3

190’ ROHN 45GSR Al l p ar ts shown i n tabl e a re i n c l uded when order i ng Pa r t No: 45GS R 110R 190

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 1

3

3

3

FDNS 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR 10

1

5

1

FB2G AB4

1/4EHS

142265

3/8THH

5/8TBE&J

2425’

800’

24

15

7/16THH

BG2144

BG2146

TBSAFETY

6

24

6

3

200’ ROHN 45GSR Al l p ar ts shown i n tabl e a re i n c l uded when order i ng Pa r t No: 45GS R 110R 200

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 1 0 M P H R E V. G 208’ 175’ 135’ 95’ 55’

220’ TOWER 33.3 OR 25.8 273’ 248’ 222’ 200’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

184’

GUYS & CONNECTIONS INCLUDED

176’

P/N: 45GSR110R220

ANCHORS & GROUNDING INCLUDED

228’ 195’ 155’ 115’ 75’ 35’

240’ TOWER 32.2 OR 25.1 298’ 274’ 247’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

150’ 122’ 102’ 96’

GUYS & CONNECTIONS INCLUDED

192’

P/N: 45GSR110R240

ANCHORS & GROUNDING INCLUDED

248’ 215’ 175’ 135’

260’ TOWER 31.0 OR 24.5 324’ 299’ 272’

95’

175’

55’

147’ 125’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

112’ 208’

P/N: 45GSR110R260

ANCHORS & GROUNDING INCLUDED

268’ 235’ 195’ 155’ 115’ 75’ 35’

280’ TOWER 30.4 OR 24.0 349’ 325’ 297’ 272’ 150’ 122’ 102’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

96’

GUYS & CONNECTIONS INCLUDED

224’

P/N: 45GSR110R280

ANCHORS & GROUNDING INCLUDED

FDNS 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR 11

1

5

1

G

45GSR

SOLID ROD

FB2G AB4

1/4EHS

142265

3/8THH

5/8TBE&J

2725’

875’

24

15

7/16THH

BG2144

BG2146

TBSAFETY

6

24

6

3

220’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 110R 220

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 1

3

3

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

12

1

6

1

FB2G AB2

AB3

1/4EHS

142265

BG2144

BG2146

3/8THH

2850’

950’

30

6

30

7/16THH

5/8TBE&J

6

9

1/2TBE&J CPC.5/.75 CPC1/1.25 3

9

240’ ROHN 45GSR Al l par ts shown i n ta b l e are i nc l uded when ord er i ng Pa r t No: 45GS R 110R 240

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

2

3

6

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

13

1

6

1

FB2G AB2

AB3

1/4EHS

142265

BG2144

BG2146

3/8THH

3250’

1050’

30

6

30

7/16THH

5/8TBE&J

6

9

260’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 260

1/2TBE&J CPC.5/.75 CPC1/1.25 3

9

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

2

3

6

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

14

1

7

1

FB2G AB2

AB4

1/4EHS

142265

BG2144

BG2146

3/8THH

4050’

1125’

36

6

36

7/16THH

5/8TBE&J

6

12

280’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 110R 280

1/2TBE&J CPC.5/.75 CPC1/1.25 9

3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

3

2

3

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

83


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 1 0 M P H R E V. G 288’ 248’ 215’ 175’ 135’ 95’ 55’

300’ TOWER 29.7 OR 23.5 375’ 345’ 322’ 297’

5/16” EHS (1,120#) 1/4” EHS (665#)

175’ 147’ 125’

TOWER PARTS INCLUDED

112’

GUYS & CONNECTIONS INCLUDED

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

15

142265

BG2144

BG2146

3/8THH

3400’

2300’

30

12

30

7/16THH

5/8TBE&J

12

12

P/N: 45GSR110R300

308’

320’ TOWER 28.9 OR 23.0 401’

268’ 235’ 195’ 155’ 115’ 75’ 35’

3/8”EHS (1,540#)

371’ 348’ 322’

5/16” EHS (1,120#) 1/4” EHS (665#)

201’ 172’ 148’ 133’ 128’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED

256’

288’ 255’ 215’ 175’ 135’ 95’ 55’

340’ TOWER 28.1 OR 22.6 426’ 3/8”EHS (1,540#) 396’ 5/16” EHS (1,120#) 373’ 1/4” EHS (665#) 347’ 227’ 197’ 173’ 154’

3

9

3

GAC3455TOP GAC5655TOP AGK1GGX BGK3GGX TBSAFETY 3

2

3

6

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

15

4225’

1

7

1

AB4

FB2G AB3

TOWER PARTS INCLUDED

1200’

6

36

1300’

1/2THH 3/8THH 7/16THH 5/8TBE&J 6

ANCHORS & GROUNDING INCLUDED

24

6

36

6

3

5/8S

45GSR20L82*

3

1

144’ 272’

2

6

3

6

6

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

16

4700’

1

7

1

ANCHORS & GROUNDING INCLUDED

1275’

1375’

36

1/2THH 3/8THH 7/16THH 5/8TBE&J 6

P/N: 45GSR110R340

320’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 110R 320

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 TBSAFETY

AB4

FB2G AB3

1/4EHS 142265 142261 BG2144 BG2146 BG2147 5/8S GUYS & CONNECTIONS INCLUDED

300’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 110R 300

1/2TBE&J CPC.5/.75 CPC1/1.25

1/4EHS 142265 142261 BG2144 BG2146 BG2147 5/8S

P/N: 45GSR110R320

328’

AB4

FB2G AB2

1/4EHS

240’

ANCHORS & GROUNDING INCLUDED

1

7

1

45GSR

SOLID ROD

6

36

24

6

6

3

5/8S

45GSR20L82*

3

1

340’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 110R 340

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 TBSAFETY 6

2

3

6

6

* Guy lug sections required for 3/8” guys.

84

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 35’

40’ TOWER 47.3 OR 33.5 47’ 1/4” EHS (665#)

32’

P/N: 45GSR130R040

45’

50’ TOWER 44.1 OR 28.6 60’ 1/4” EHS (665#)

40’

P/N: 45GSR130R050

48’

60’ TOWER 35.0 OR 24.0 68’ 5/16” EHS (1,120#)

48’

P/N: 45GSR130R060

58’

70’ TOWER 33.2 OR 22.8 81’

35’

66’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

56’

GUYS & CONNECTIONS INCLUDED

P/N: 45GSR130R070

ANCHORS & GROUNDING INCLUDED

45GSR20

45GSRSB

GA45GD

2

1

1

1/4EHS

BG2144

3/8THH

150’

6

6

G

45GSR

SOLID ROD

FDNS

BASE ANCHOR

FB2G AB2 1/2TBE&J TBSAFETY 3

3

40’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 130R 040

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

2

1

1

1/4EHS

BG2144

3/8THH

200’

6

6

3 FDNS

GA45GD 1

BASE ANCHOR

FB2G AB2

1/2TBE&J TBSAFETY 3

3

50’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 90R 050

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

3

1

1

142265

BG2146

225’

6

3 FDNS

BASE ANCHOR

FB2G AB2

7/16THH 5/8TBE&J TBSAFETY 6

3

3

60’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Par t No: 45GS R 90R 060

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

3

GA45GD

FDNS

BASE ANCHOR

3

1

1

2

1/4EHS

142265

BG2144

BG2146

3/8THH

225’

275’

6

6

6

7/16THH

1/2TBE&J

6

3

FB2G AB2

5/8TBE&J TBSAFETY 3

70’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 130R 070

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

85


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 68’

80’ TOWER 31.5 OR 21.9 93’

35’

73’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

64’

P/N: 45GSR130R080

ANCHORS & GROUNDING INCLUDED

78’

90’ TOWER 30.2 OR 21.1 106’

45’

85’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

GUYS & CONNECTIONS INCLUDED

72’

P/N: 45GSR130R090

ANCHORS & GROUNDING INCLUDED

88’

100’ TOWER 29.1 OR 20.5

TOWER PARTS INCLUDED

119’ 5/16” EHS (1,120#) 55’

97’

1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

80’

P/N: 45GSR130R100

ANCHORS & GROUNDING INCLUDED

98’

110’ TOWER 28.0 OR 19.9 132’

65’ 109’ 35’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

95’

GUYS & CONNECTIONS INCLUDED

88’

P/N: 45GSR130R110

ANCHORS & GROUNDING INCLUDED

86

FDNS

45GSRSB

GA45GD

4

1

2

FB2G AB2

1/4EHS

142265

BG2144

BG2146

3/8THH

250’

300’

6

6

6

7/16THH

1/2TBE&J

6

3

BASE ANCHOR

80’ ROHN 45GSR Al l p ar ts shown i n tabl e a re i n c l ud ed when ord er i ng Pa r t No: 45GS R 130R 080

5/8TBE&J TBSAFETY 3

45GSR

SOLID ROD

45GSR20

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

3 FDNS

GA45GD

BASE ANCHOR

4

1

1

2

1/4EHS

142265

BG2144

BG2146

3/8THH

275’

350’

6

6

6

7/16THH

1/2TBE&J

6

3

FB2G AB2

5/8TBE&J TBSAFETY 3

90’ ROHN 45GSR Al l p ar ts shown i n tabl e a re i n c l ud ed when ord er i ng Pa r t No: 45GS R 130R 090

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

1

3

45GSR20

45GSRSB

GA45GD

5

1

2

FB2G AB2

1/4EHS

142265

BG2144

BG2146

3/8THH

325’

400’

6

6

6

7/16THH

1/2TBE&J

6

3

3 FDNS

BASE ANCHOR

5/8TBE&J TBSAFETY 3

100’ ROHN 45GSR Al l par ts shown i n tabl e a re i n cl ud ed when ord er i ng Pa r t No: 45GS R 130R 100

3

GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3

45GSR20

1

3

45GSR10 45GSRSB

3 GA45GD

5

1

1

3

1/4EHS

142265

BG2144

BG2146

650’

425’

12

6

3/8THH

7/16THH

12

6

5/8TBE&J TBSAFETY 9

FDNS

BASE ANCHOR

FB2G AB3

110’ ROHN 45GSR Al l par ts shown i n tabl e a re i n cl ud ed when ord er i ng Pa r t No: 45GS R 130R 110

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 108’

120’ TOWER 27.0 OR 19.3 144’ 5/16” EHS (1,120#)

75’ 122’ 35’

TOWER PARTS INCLUDED

1/4” EHS (665#)

102’

GUYS & CONNECTIONS INCLUDED

96’

P/N: 45GSR130R120

ANCHORS & GROUNDING INCLUDED

118’

130’ TOWER 26.3 OR 18.7 157’ 5/16” EHS (1,120#)

85’ 134’ 45’

TOWER PARTS INCLUDED

1/4” EHS (665#)

113’

GUYS & CONNECTIONS INCLUDED

104’

P/N: 45GSR130R130

ANCHORS & GROUNDING INCLUDED

128’

140’ TOWER 25.6 OR 18.4 170’ 5/16” EHS (1,120#)

95’ 147’ 55’

TOWER PARTS INCLUDED

1/4” EHS (665#)

125’

GUYS & CONNECTIONS INCLUDED

112’

P/N: 45GSR130R140

ANCHORS & GROUNDING INCLUDED

138’ 105’

150’ TOWER 24.7 OR 18.0 183’ 159’

65’ 35’

136’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

125’

GUYS & CONNECTIONS INCLUDED

120’

P/N: 45GSR130R150

ANCHORS & GROUNDING INCLUDED

FDNS

45GSR20

45GSRSB

GA45GD

6

1

3

FB2G AB3

1/4EHS

142265

BG2144

BG2146

725’

475’

12

6

3/8THH

7/16THH

12

6

45GSR

SOLID ROD

BASE ANCHOR

120’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 130R 120

5/8TBE&J TBSAFETY 9

G

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

45GSR20

1

3

45GSR10 45GSRSB

3 FDNS

GA45GD

6

1

1

3

1/4EHS

142265

BG2144

BG2146

800’

500’

12

6

3/8THH

7/16THH

12

6

BASE ANCHOR

FB2G AB3

130’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 130R 130

5/8TBE&J TBSAFETY 9

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

1

3

45GSR20

45GSRSB

GA45GD

7

1

3

FB2G AB3

1/4EHS

142265

BG2144

BG2146

875’

550’

12

6

3/8THH

7/16THH

12

6

3 FDNS

BASE ANCHOR

140’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 130R 140

5/8TBE&J TBSAFETY 9

3

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 3

45GSR20

1

3

45GSR10 45GSRSB

3 GA45GD

7

1

1

4

1/4EHS

142265

BG2144

BG2146

1350’

600’

18

6

3/8THH

7/16THH

18

6

FDNS

BASE ANCHOR

FB2G AB4

3/4TBE&J TBSAFETY 12

150’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 130R 150

3

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

87


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 148’ 115’

160’ TOWER 24.0 OR 17.7 196’ 172’

75’ 35’

148’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

133’

GUYS & CONNECTIONS INCLUDED

128’

P/N: 45GSR130R160

ANCHORS & GROUNDING INCLUDED

158’ 125’

170’ TOWER 23.4 OR 17.3 208’ 185’

85’ 45’

TOWER PARTS INCLUDED

160’

5/16” EHS (1,120#) 1/4” EHS (665#)

143’

GUYS & CONNECTIONS INCLUDED

136’

P/N: 45GSR130R170

ANCHORS & GROUNDING INCLUDED

168’ 135’

180’ TOWER 22.8 OR 16.9 221’ 197’

95’ 55’

173’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

154’

GUYS & CONNECTIONS INCLUDED

144’

P/N: 45GSR130R180

ANCHORS & GROUNDING INCLUDED

178’ 145’ 105’ 65’ 35’

190’ TOWER 22.3 OR 16.5 234’ 210’ 185’ 165’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#)

156’

GUYS & CONNECTIONS INCLUDED

152’

P/N: 45GSR130R190

ANCHORS & GROUNDING INCLUDED

88

FDNS

45GSR20

45GSRSB

GA45GD

8

1

4

FB2G AB4

1/4EHS

142265

BG2144

BG2146

1450’

625’

18

6

3/8THH

7/16THH

18

6

160’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c l u d ed when ord er i ng Pa r t No: 45GS R 130R 160

3/4TBE&J TBSAFETY 12

45GSR

SOLID ROD

BASE ANCHOR

3

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 3

45GSR20

1

3

45GSR10 45GSRSB

3 FDNS

GA45GD

8

1

1

4

1/4EHS

142265

BG2144

BG2146

1575’

675’

18

6

3/8THH

7/16THH

18

6

BASE ANCHOR

FB2G AB4

170’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c l u d ed when ord er i ng Pa r t No: 45GS R 130R 170

3/4TBE&J TBSAFETY 12

3

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 3

1

3

45GSR20

45GSRSB

GA45GD

9

1

4

FB2G AB4

1/4EHS

142265

BG2144

BG2146

1675’

725’

18

6

3/8THH

7/16THH

18

6

3 FDNS

BASE ANCHOR

180’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c l u d ed when ord er i ng Pa r t No: 45GS R 130R 180

3/4TBE&J TBSAFETY 12

3

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 3

45GSR20

1

3

45GSR10 45GSRSB

3 GA45GD

9

1

1

5

1/4EHS

142265

BG2144

BG2146

2300’

750’

24

6

3/8THH

7/16THH

24

6

3/4TBE&J TBSAFETY 15

FDNS

BASE ANCHOR

FB2G AB4

190’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c l u d ed when ord er i ng Pa r t No: 45GS R 130R 190

3

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 3

1

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 188’ 148’ 115’ 75’ 35’

200’ TOWER 21.9 OR 16.2 247’

TOWER PARTS INCLUDED

5/16” EHS 218’ (1,120#) 197’ 177’

1/4” EHS (665#)

164’

GUYS & CONNECTIONS INCLUDED

160’

P/N: 45GSR130R200

ANCHORS & GROUNDING INCLUDED

208’ 168’

220’ TOWER 21.0 OR 15.5 272’ 3/8” EHS (1,540#)

TOWER PARTS INCLUDED

243’ 135’ 95’ 55’

222’ 200’

5/16” EHS (1,120#) 1/4” EHS (665#)

184’ 176’

P/N: 45GSR130R220

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

228’ 188’ 155’ 108’ 75’ 35’

240’ TOWER 20.2 OR 15.0 298’ 269’ 247’ 144’ 122’ 102’

TOWER PARTS INCLUDED

3/8”EHS (1,540#) 1/4” EHS (665#) 5/16”EHS (1,120#)

96’ 192’

P/N: 45GSR130R240

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

45GSR20 45GSRSB GA45GD APL4A 10

1

5

1

FDNS

G

45GSR

SOLID ROD

BASE ANCHOR

FB2G AB4

1/4EHS

142265

BG2144

BG2146

1725’

1500’

18

12

3/8THH

7/16THH

18

12

200’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 130R 200

3/4TBE&J TBSAFETY 3

15

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 1

3

3

3

45GSR20 45GSRSB GA45GD APL4A 10

1

4

1

FDNS

BASE ANCHOR

FB2G AB4

1/4EHS

142265

142261

1950’

775’

875’

18

BG2146

BG2147

7/16THH

1/2THH

6

6

6

6

3/8THH

5/8S

18

3

BG2144 45GSR20L82* 1

220’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 130R 220

3/4TBE&J TBSAFETY 3

15

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 1

3

3

3

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

11

1

5

1

FB2G AB3

1/4EHS

142265

142261

1500’

1325’

950’

18

BG2146

BG2147

7/16THH

1/2THH

12

6

12

6

3/8THH

5/8S

18

3

AB4

BG2144 45GSR20L82* 1

240’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l uded when order i ng Pa r t No: 45GS R 130R 240

5/8TBE&J TBSAFETY 18

6

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 6

2

3

6

* Guy lug section required for 3/8” guys.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

89


G

GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 248’ 208’ 175’ 128’

260’ TOWER 19.6 OR 14.6 324’ 294’ 272’

95’

170’

55’

147’ 125’

TOWER PARTS INCLUDED

3/8” EHS (1,540#) 1/4” EHS (665#) 5/16”EHS (1,120#) 112’ 208’

P/N: 45GSR130R260

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

268’ 228’ 188’ 148’ 115’ 75’ 35’

280’ TOWER 19.0 OR 14.3 349’ 320’ 292’ 268’ 150’ 122’ 102’

TOWER PARTS INCLUDED

3/8” EHS (1,540#) 1/4” EHS (665#) 5/16”EHS (1,120#) 96’

224’

P/N: 45GSR130R280

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

288’ 248’ 208’ 168’ 135’ 95’ 55’

300’ TOWER 18.4 OR 14.0 375’ 345’ 318’ 293’

3/8” EHS (1,540#) 1/4” EHS (665#) 5/16”EHS (1,120#)

175’ 147’ 125’

TOWER PARTS INCLUDED

112’

240’

P/N: 45GSR130R300

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

12

1

5

1

FB2G AB3

1/4EHS

142265

142261

1750’

1500’

1050’

18

BG2146

BG2147

7/16THH

1/2THH

12

6

12

6

3/8THH

5/8S

18

3

45GSR

SOLID ROD

AB4

BG2144 45GSR20L82* 1

260’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c luded when order i ng Pa r t No: 45GS R 130R 260

5/8TBE&J TBSAFETY 6

18

GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25 2

6

3

6

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

13

1

6

1

FB2G AB3

1/4EHS

142265

142261

1200’

2800’

1125’

18

BG2146

BG2147

7/16THH

1/2THH

18

6

18

6

3/8THH

5/8S

18

3

AB5

BG2144 45GSR20L82* 1

280’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c luded when order i ng Pa r t No: 45GS R 130R 280

3/4TBE&J TBSAFETY 6

21

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 2

6

3

6

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

14

1

6

1

FB3G AB3

1/4EHS

142265

142261

1425’

3050’

1200’

18

BG2146

BG2147

7/16THH

1/2THH

18

6

18

6

3/8THH

5/8S

18

3

AB5

BG2144 45GSR20L82* 1

300’ ROHN 45GSR Al l par ts shown i n tabl e a re i n c luded when order i ng Pa r t No: 45GS R 130R 300

3/4TBE&J TBSAFETY 21

6

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 6

2

3

6

* Guy lug section required for 3/8” guys.

90

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

S TA N D A R D D E S I G N - 4 5 G S R 1 3 0 M P H R E V. G 308’ 268’ 228’ 188’ 148’ 115’ 75’ 35’

320’ TOWER 17.8 OR 13.8 400’ 371’ 343’ 318’

TOWER PARTS INCLUDED

3/8” EHS (1,540#) 1/4” EHS (665#)

5/16”EHS 196’ (1,120#) 172’ 148’ 133’ 128’ 256’

P/N: 45GSR130R320

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

328’ 288’ 248’ 208’ 168’ 135’ 95’ 55’

340’ TOWER 17.4 OR 12.5 426’ 396’ 368’ 342’ 221’ 197’ 173’ 154’

TOWER PARTS INCLUDED

3/8” EHS (1,540#) 1/4” EHS (665#) 5/16”EHS (1,120#) 144’ 272’

P/N: 45GSR130R340

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

14

1

6

1

FB3G AB3

1/4EHS

142265

142261

1450’

2750’

2475’

18

BG2146

BG2147

7/16THH

1/2THH

18

12

18

12

3/8THH

5/8S

18

6

G

45GSR

SOLID ROD

AB5

BG2144 45GSR20L82* 2

320’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Pa r t No: 45GS R 130R 320

3/4TBE&J TBSAFETY 6

24

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 2

6

3

6

INNER OUTER 45GSR20 45GSRSB GA45GD APL4A BASE ANCHOR ANCHOR

14

1

5

1

FB3G AB4

1/4EHS

142265

142261

1675’

1800’

3800’

18

BG2146

BG2147

7/16THH

1/2THH

12

18

12

18

3/8THH

5/8S

18

9

AB5

BG2144 45GSR20L82* 3

340’ ROHN 45GSR Al l par ts shown i n tabl e a re i nc l ud ed when ord er i ng Par t No: 45GS R 130R 340

3/4TBE&J TBSAFETY 24

6

GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2 6

2

3

6

* Guy lug section required for 3/8” guys.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

91


G

GUYED TOWERS - 45GSR

PA R T S & A CC E S S O R I E S LIGHTNING ROD LRCL

5’ COPPER CLAD ORDERED SEPARATELY.

17”

LEG MOUNTED BEACON PLATE KIT APL4A FOR MOUNTING BEACON OR LIGHTNING ROD. BOLTS TO TOP OF STANDARD SECTION. INCLUDES BEACON PLATE, (2) CAP PLATES, NUTS AND BOLTS.

LIGHTNING ROD PLATE KIT VW132

INCLUDES: LIGHTNING ROD PLATE, NUTS AND BOLTS.

TAPERED BASE 45GSRTBPP* FOR USE WITH PIER PIN (3/4X12PP) AND BEARING PLATE (BP6) SOLD SEPARATELY.

3’ SIDE ARM WITH (2) TIE BACKS KY1653A MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 3/8” O.D.

Beacon Plate

Ice Shield

MID BEACON PLATE / ICE SHIELD APL1258UM

4.3’ SHORT BASE 45GSRSB

FOR EMBEDMENT IN CONCRETE.

Refer to pages 63-65 for the following accessories that also fit the 45GSR tower: • Pier Pin (3/4x12PP) • Side Arm Bracket (SA253UA) • Dish Mount (VY4311A2 & VY4311A) • Face Mount (DM45G2 & DM454) • Universal House Bracket (HBUTVRO) • Torque Bar (TB45D) • Guy Bracket (GA45GD)

• Anti-Climb Panels (VW913A) • Work Platform (WP45G) • Safety Ring (SR245) • Climbing Harness (TTFBH-4D & TTFBH-C/P) • Safety Cable Slider (TT-WG-500-W/SMC) • Safety Cable System (See page 65 for P/N)

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

92

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 45GSR

A N C H O R I N F O R M AT I O N 81”

12”

3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4”

4” x 4” x 3/8” angle

2”

GAC3455TOP

11/16”

120”

12”

1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4”

5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP 168”

12”

3/4” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 7/16”

5” x 5” x 3/8” angle

3” 15/16”

GAC5755TOP REV G BASE GROUNDING BGK3GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp Ground Wire Clamp

Ground Wire

Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed o at 120 separation at 20’ spacing.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

93


G

GUYED TOWERS - 45GSR

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required

o

Top and bottom horizontal bars equally spaced

A B

C

D

Refer to pages 95-96 for anchor rod installation angles.

94

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

Anchor Rod Angle

45GSR | 90MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’

Inner Rod Number GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC5655TOP GAC5655TOP GAC5655TOP GAC5655TOP GAC5655TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP GAC3455TOP

Inner Rod Angle 48 49 49 44 43 44 44 42 42 42 42 40 40 40 41 40 40 40 38 40 38 40 37 38

Ground Line

45GSR | 110MPH

Outer Rod Outer Rod Number Angle GAC3455TOP 46 GAC3455TOP 46 GAC5655TOP 44 GAC5655TOP 44 GAC5655TOP 45 GAC5655TOP 45

Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 48 GAC3455TOP 49 GAC3455TOP 49 GAC3455TOP 43 GAC3455TOP 42 GAC3455TOP 43 GAC3455TOP 44 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 41 GAC3455TOP 42 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC3455TOP 39 GAC5655TOP 45 GAC3455TOP 40 GAC5655TOP 45 GAC3455TOP 39 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 44 GAC5655TOP 40 GAC5655TOP 44 GAC5655TOP 40 GAC5655TOP 44

See the following page for 45GSR | 130mph anchor rod slopes.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

95


G

GUYED TOWERS - 45GSR

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

Ground Line

Anchor Rod Angle

45GSR | 130MPH Tower Height 40’ 50’ 60’ 70’ 80’ 90’ 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’

96

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 48 GAC3455TOP 48 GAC3455TOP 45 GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 43 GAC3455TOP 43 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 41 GAC5655TOP 41 GAC5755TOP 39 GAC5755TOP 38 GAC5755TOP 39 GAC5755TOP 39 GAC5755TOP 37 GAC5755TOP 38 GAC5755TOP 38 GAC5655TOP 40 GAC5655TOP 45 GAC5655TOP 41 GAC5655TOP 45 GAC5755TOP 38 GAC5755TOP 42 GAC5755TOP 39 GAC5755TOP 43 GAC5755TOP 37 GAC5655TOP 43 GAC5755TOP 38 GAC5655TOP 43

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

G

S TA N D A R D M AT F O U N D AT I O N FOR 45GSR TOWERS

45GSR Tower Section or Short Base Section, placed with center of tower at center of foundation

2” min. projection above the finished concrete

Grade

6”

4’ 0”

0” to 3” W (Square)

Base

No. 7 Bars 12” O.C., each way, top and bottom

Mat Width Concrete Vol. (W) (Cu. Yds.)

FB1G

4’ - 6”

3.0

FB2G

5‘-3“

4.1

FB3G

6’-3”

5.8

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

97


G

GUYED TOWERS - 45GSR

S TA N D A R D M E T E O R O LO G I C A L T O W E R S Complete Kit Includes: - Assembly and foundation drawings - All necessary tower sections - Tower short base - All guy wire and connectors - All guy anchors - Base and anchor grounding kits

100 m 318’

80 m

268’

60 m

250’ 218’ 198’

190’

331’ 158’ 148‘

197’

262’

148’

98’

98’

98’

48’

48’

48’

60MMET 4 Guy Elevations 1 Fixed Base Foundation 1 Anchor Radius

80MMET 5 Guy Elevations 1 Fixed Base Foundation 1 Anchor Radius

Boom EPA / WT. EPA / WT. Height (no ice) (3/4”radial ice) 40 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs. 50 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs. 60 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs.

Boom EPA / WT. EPA / WT. Height (no ice) (3/4”radial ice) 60 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs. 70 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs. 80 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs.

ANSI/TIA-222-G 110 MPH - 3 Second Gust (No Ice) 50 MPH - 3 Second Gust (3/4” Radial Ice) Structure Class II Exposure Category C Topographic Category I

ANSI/TIA-222-G 110 MPH - 3 Second Gust (No Ice) 50 MPH - 3 Second Gust (3/4” Radial Ice) Structure Class II Exposure Category C Topographic Category I

98

100MMET 6 Guy Elevations 1 Fixed Base Foundation 2 Anchor Radii Boom EPA / WT. EPA / WT. Height (no ice) (3/4”radial ice) 50 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs. 75 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs. 100 m 9.00 sq. ft. / 200 lbs. 25.00 sq. ft. / 600 lbs.

ANSI/TIA-222-G 110 MPH - 3 Second Gust (No Ice) 50 MPH - 3 Second Gust (3/4” Radial Ice) Structure Class II Exposure Category C Topographic Category I

Tower design assumes (1) elevator track over height of structure. Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 45GSR

G

S TA N D A R D 4 5 G S R METEOROLOGICAL TOWER

9 21/32” 14 1/2”

Base Anchor Tower Guy Radius (ft.) Foundation Foundation Height 120 o separation No. No. (m) 16 3/4”

60

156

FB2G

AB4

80

210

FB3G

AB5

100

106 / 264

FB3G

AB2 / AB6

Refer to page 288 for anchor rod details. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 94 & 97. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

Optional Waveguide Brackets (KY2041A) 1 1/4” O.D. Solid Round 7/16” or 5/8” O.D. Solid Bracing

1 1/4” O.D. Solid Round Double braced sections provided where required.

7/16” O.D. Solid Bracing

4.3’ 45GSR SHORT BASE 45GSRSB TO BE EMBEDDED IN CONCRETE.

STANDARD SECTION 45GSR10 - 10’ Section 45GSR20 - 20’ Section

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

99


G

GUYED TOWERS - 55G

S TA N D A R D 5 5 G G U Y E D T O W E R

ROHN 55G The first. The original.

includes

REV. F & REV. G

55G

GENERAL USE The 55G lends itself to a wide variety of uses, particularly where unusual wind loading and height requirements exist. The 55G was designed to provide excellent strength in heights up to 400’.

FEATURES • Completely hot-dip galvanized after fabrication • Built on a 17” equilateral triangle design • High strength tubular legs joined by Zig-Zag®

cross members

• Each section contains all required nuts and bolts

shipped with section

• Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 116 for ordering information.

100

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D 5 5 G G U Y E D T O W E R SECTIONS 9 13/16” 14 3/4”

QUICK REFERENCE PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION

17”

PAGES 115-116 PAGE 117 PAGES 117-120

Optional Waveguide Brackets (KY2041A)

TOP PLATE APL55G

1 1/2” O.D. (11 GA.)

FOR MOUNTING BEACON OR LIGHTNING ROD. TOP PLATE BOLTS TO THE TOP OF A STANDARD SECTION.

7/16” O.D. Solid Bracing

Optional double braced sections are available upon request.

CONCRETE BASE PLATE BPC55G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. Additional base sections are available, please see page 115.

STANDARD SECTION 55G - 10’ Section * Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

101


G

GUYED TOWERS - 55G

BUYERS GUIDE S TA N D A R D D E S I G N S - 5 5 G 9 0 M P H R E V. G [ 3 S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 30.4

39.0

85’

EPA (SQ. FT.) For Exposure C, Revision G

32.0 117’

42’

90’

1/4” EHS (665#) 3/16” EHS (399#)

EPA (SQ. FT.), Revision F Guy Initial Tension

P/N 55G90R100 80’

P/N 55G90R100

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 55G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 117-120. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

102

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 100’ TOWER 39.0 OR 30.4

85’

32.0 117’ 1/4” EHS (665#)

42’

90’

3/16” EHS (399#)

80’

P/N: 55G90R100

95’

110’ TOWER 37.9 OR 29.8 31.2 129’ 1/4” EHS (665#)

47’

100’

3/16” EHS (399#)

88’

P/N: 55G90R110

105’

120’ TOWER 37.0 OR 29.3 30.4 142’ 3/16” EHS (399#)

75’ 122’ 35’

1/4” EHS (665#)

102’ 96’

P/N: 55G90R120

115’

130’ TOWER 36.1 OR 28.7 29.8 155’ 3/16” EHS (399#)

76’ 129’ 38’

1/4” EHS (665#)

111’ 104’

P/N: 55G90R130

125’

140’ TOWER 35.4 OR 28.3 29.0 168’ 3/16” EHS (399#)

83’ 139’ 41’

1/4” EHS (665#)

119’ 112’

P/N: 55G90R140

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

10

1

1

GA55GD BASEFDNS ANCHOR 2

100’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 100

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 300’

6

375’

6

6

6

6

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

11

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 2

110’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 110

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 325’

6

425’

6

6

6

6

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

12

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 3

120’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 120

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’

12

475’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

13

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 3

130’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 130

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 775’

12

500’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

14

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 3

140’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 140

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 825’

12

550’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

103


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 150’ TOWER 34.7 OR 27.9 28.6

135’

181’ 3/16” EHS (399#)

92’ 151’ 45’

1/4” EHS (665#)

128’ 120’

P/N: 55G90R150 160’ TOWER 33.9 OR 27.5 28.0

145’

193’ 3/16” EHS (399#)

96’ 160’ 48’

1/4” EHS (665#)

137’ 128’

P/N: 55G90R160

170’ TOWER 33.3 OR 27.2 27.4

155’

206’

115’

178’ 75’

155’

1/4” EHS (665#) 3/16” EHS (399#)

141’

37’

136’

P/N: 55G90R170 180’ TOWER 32.8 OR 26.8 27.0

165’

219’

124’

190’ 83’

166’

1/4” EHS (665#) 3/16” EHS (399#)

150’

42’

144’

P/N: 55G90R180 190’ TOWER 32.4 OR 26.5 26.6

175’

232’

131’

201’ 87’

175’

5/16” EHS (1,120#) 3/16” EHS (399#)

158’

43’

152’

P/N: 55G90R190

104

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

15

1

1

GA55GD BASEFDNS ANCHOR 3

150’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 150

CB2G AB2

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 900’

12

600’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

16

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 3

160’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 160

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 950’

12

625’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

17

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 4

170’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 170

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1525’

18

675’

6

18

6

12

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

18

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 4

180’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 180

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1625’

18

700’

6

18

6

12

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

19

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 4

190’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 190

3/16EHS142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1700’

18

750’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 185’ 139’

200’ TOWER 31.9 OR 26.2 24.2 245’ 212’

93’ 47’

185’

5/16” EHS (1,120#) 3/16” EHS (399#)

167’ 160’

P/N: 55G90R200

205’ 164’ 123’ 82’ 41’

220’ TOWER 31.1 OR 25.7 23.4 270’ 3/16” EHS 241’ (399#) 215’

5/16”EHS (1,120#)

194’ 181’

176’

P/N: 55G90R220

225’ 182’ 135’ 92’ 45’

240’ TOWER 30.3 OR 25.3 22.8 296’ 3/16” EHS 265’ (399#) 5/16” EHS (1,120#) 235’ 213’ 197’ 192’

P/N: 55G90R240

245’ 202’ 162’ 122’ 82’ 42’

260’ TOWER 29.6 OR 24.8 22.2 321’ 290’ 5/16” EHS (1,120#) 264’ 3/16” EHS (399#) 241’ 104’ 77’ 64’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

208’

P/N: 55G90R260

ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

20

1

1

GA55GD BASEFDNS ANCHOR 4

CB2G AB3

200’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 200

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1800’

18

800’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

22

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 5

CB2G AB3

220’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 220

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 3/4TBE&J 2650’

24

875’

6

24

6

15

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

24

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 5

CB3G AB3

240’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 240

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 3/4TBE&J 2900’

24

950’

6

24

6

15

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

26

1

1

6

3/16EHS

142265

BG2142

BG2146

5/16THH

3125’

1025’

30

6

30

7/16THH

1/2TBE&J

5/8TBE&J

6

6

12

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB3G AB2

AB3

260’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 260

CPC.5/.75 CPC1/1.25 3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 3

3

2

3

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

105


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 280’ TOWER 29.0 OR 24.4

265’

21.8

222’

347’ 315’ 5/16” EHS (1,120#) 284’ 3/16” EHS (399#) 260’

175’ 132’ 85’

110’ 82’

43’

70’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

224’

P/N: 55G90R280

ANCHORS & GROUNDING INCLUDED 300’ TOWER 28.4 OR 24.1

285’

21.2

242’

373’ 341’ 5/16” EHS (1,120#) 314’ 3/16” EHS (399#) 290’

202’ 162’ 122’ 82’ 42’

158’ 129’ 108’ 100’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

240’

P/N: 55G90R300

ANCHORS & GROUNDING INCLUDED 320’ TOWER 27.9 OR 23.8

305’

20.8

262’

398’ 366’ 5/16” EHS (1,120#) 334’ 3/16” EHS (399#) 308’ 1/4”EHS (665#) 160’ 129’ 108’

215’ 172’ 125’ 82’ 42’

100’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

256’

P/N: 55G90R320

ANCHORS & GROUNDING INCLUDED 340’ TOWER 27.4 OR 23.5

325’

20.4

282’ 242’ 202’ 162’

424’ 392’ 364’ 339’ 317’

122’ 82’ 42’

155’ 126’ 105’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

96’

GUYS & CONNECTIONS INCLUDED

272’

P/N: 55G90R340

ANCHORS & GROUNDING INCLUDED

106

INNER OUTER BASE ANCHOR ANCHOR

55G

BPC55G

APL55G

GA55GD

28

1

1

6

CB4G AB2

3/16EHS

142265

BG2142

BG2146

5/16THH

3350

1125’

30

6

30

7/16THH

1/2TBE&J

5/8TBE&J

6

6

12

AB3

280’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 280

CPC.5/.75 CPC1/1.25 3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 6

3

3

2

3

55G

BPC55G

APL55G

GA55GD

30

1

1

7

CB4G AB2

3/16EHS

142265

BG2142

BG2146

5/16THH

4275’

1200’

36

6

36

7/16THH

1/2TBE&J

6

9

1

INNER OUTER BASE ANCHOR ANCHOR

AB3

300’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 300

5/8TBE&J CPC.5/.75 CPC1/1.25 12

3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 3

3

2

3

55G

BPC55G

APL55G

GA55GD

32

1

1

7

3/16EHS

1/4EHS

142265

BG2142

2250’

2250’

1275’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

12

6

9

6

1

INNER OUTER BASE ANCHOR ANCHOR

CB4G AB2 BG2144

AB3 BG2146

320’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 320

12

6

12

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

2

3

55G

BPC55G

APL55G

GA55GD

34

1

1

8

CB4G AB2

3/16EHS

1/4EHS

142265

BG2142

BG2144

3325’

2425’

1350’

30

5/16THH

3/8THH

7/16THH

1/2TBE&J

30

12

6

9

3

1

INNER OUTER BASE ANCHOR ANCHOR

AB3 BG2146

340’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 340

12

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 360’ TOWER 27.0 OR 23.2

345’

20.0

302’ 255’ 212’ 168’

449’ 417’ 385’ 358’ 333’

126’ 84’ 42’

161’ 131’ 108’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

100’ 288’

P/N: 55G90R360

ANCHORS & GROUNDING INCLUDED

365’ 319’ 273’ 227’ 181’ 135’ 92’ 45’

380’ TOWER 26.6 OR 22.9 475’ 441’ 409’ 379’ 354’ 174’ 143’ 119’

19.6

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

110’ 304’

P/N: 55G90R380

ANCHORS & GROUNDING INCLUDED

385’ 335’ 285’ 235’ 185’ 138’ 92’ 46’

400’ TOWER 26.1 OR 22.7 19.2 501’ 463’ 5/16” EHS 429’ (1,120#) 397’ 3/16” EHS (399#) 370’ 1/4”EHS (665#) 183’ 151’ 129’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

120’ 320’

P/N: 55G90R400

ANCHORS & GROUNDING INCLUDED

INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR

55G

BPC55G

APL55G

36

1

1

8

2

3/16EHS

1/4EHS

142265

BG2142

BG2144

3475’

2575’

1450’

30

5/16THH

3/8THH

7/16THH

1/2TBE&J

30

12

6

9

BG2146

AB4

360’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 360

12

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 3

CB5G AB2

CPC1/1.25 3

3

3

3

2

55G

BPC55G

APL55G

38

1

1

8

2

CB5G AB2

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

3175’

3275’

1525’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

18

6

9

INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR

AB4

380’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 380

18

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

3

3

2

55G

BPC55G

APL55G

40

1

1

8

2

CB5G AB2

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

2075’

4700’

1600’

18

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

5/8TBE&J

18

24

6

9

15

INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 3

3

2

3

AB4

400’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng TBSAFETY Par t No: 55G90R 400

6

6

CPC1/1.25 3/4x12PP

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

3

1

107


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 95’

100’ TOWER 26.1 OR 20.4 19.2 124’ 3/16” EHS (399#)

63’ 102’ 33’

1/4” EHS (665#)

87’ 80’

P/N: 55G110R100

105’

110’ TOWER 25.4 OR 19.9 18.6 137’ 3/16” EHS (399#)

72’ 114’ 35’

1/4” EHS (665#)

95’ 88’

P/N: 55G110R110

115’

120’ TOWER 24.8 OR 19.6 18.2 150’ 3/16” EHS (399#)

77’ 123’ 38’

1/4” EHS (665#)

103’ 96’

P/N: 55G110R120

125’

130’ TOWER 24.2 OR 19.2 17.8 163’ 3/16” EHS (399#)

83’ 133’ 42’

1/4” EHS (665#)

112’ 104’

P/N: 55G110R130

135’ 101’

140’ TOWER 23.6 OR 18.9 17.2 175’ 151’

67’ 34’

131’

1/4” EHS (665#) 3/16” EHS (399#)

117’ 112’

P/N: 55G110R140

108

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

10

1

1

GA55GD BASEFDNS ANCHOR 3

100’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 100

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 600’

12

400’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

11

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 3

110’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 110

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 675’

12

450’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

12

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 3

120’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 120

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’

12

500’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

13

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 3

130’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 130

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 800’

12

525’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

14

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 4

140’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 140

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1275’

18

575’

6

18

6

12

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 150’ TOWER 23.2 OR 18.7

145’

16.8 188’

108’

161’ 72’

140’

1/4” EHS (665#) 3/16” EHS (399#)

125’

36’

120’

P/N: 55G110R150 160’ TOWER 22.8 OR 18.4

155’

16.4 201’

116’

173’ 78’

150’

5/16” EHS (1,120#) 3/16” EHS (399#)

134’

39’

128’

P/N: 55G110R160 170’ TOWER 22.4 OR 18.2 16.2

165’

214’

124’

184’ 83’

159’

1/4” EHS (665#) 3/16” EHS (399#)

142’

41’

136’

P/N: 55G110R170 180’ TOWER 22.0 OR 18.0 15.8

175’

227’

142’

202’

105’

178’

72’

3/16” EHS (399#) 1/4” EHS (665#)

161’

35’

148’ 144’

P/N: 55G110R180

185’ 148’ 111’ 74’ 37’

190’ TOWER 21.7 OR 17.8 15.6 239’ 212’ 188’ 169’ 156’

3/16” EHS (399#) 5/16” EHS (1,120#) 1/4”EHS (665#)

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

152’

P/N: 55G110R190

ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

15

1

1

GA55GD BASEFDNS ANCHOR 4

150’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 150

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 1375’

18

600’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

16

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 4

160’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 160

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1475’

18

650’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

17

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 4

170’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 170

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 975’

12

1275’

12

12

12

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

18

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 5

180’ ROHN 55G

CB3G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 180

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 1550’

18

1375’

12

18

12

15

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

GA55GD

19

1

1

5

3/16EHS

1/4EHS

142265

BG2142

BG2144

1650’

675’

775’

18

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

18

6

6

15

3

1

FDNS

BASE ANCHOR

CB3G AB3

190’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 190

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

109


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 195’ 156’ 117’ 78’ 39’

200’ TOWER 21.4 OR 17.6 13.2 252’ 3/16” EHS 223’ (399#) 5/16” EHS (1,120#) 198’ 1/4”EHS (665#)

178’ 165’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

160’

P/N: 55G110R200

ANCHORS & GROUNDING INCLUDED 220’ TOWER 20.8 OR 17.2 12.8

215’ 182’

278’ 253’ 5/16” EHS (1,120#) 228’ 3/16” EHS (399#) 209’ 1/4”EHS (665#) 94’ 70’

145’ 112’ 73’ 36’

60’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

176’

P/N: 55G110R220

ANCHORS & GROUNDING INCLUDED

235’ 201’ 167’ 133’ 99’ 66’ 33’

240’ TOWER 20.3 OR 16.9 12.4 303’ 278’ 5/16” EHS (1,120#) 254’ 3/16” EHS (399#) 234’ 1/4”EHS (665#) 127’ 104’ 87’ 80’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

192’

P/N: 55G110R240

ANCHORS & GROUNDING INCLUDED

255’ 219’ 183’ 147’ 111’ 75’ 38’

260’ TOWER 19.8 OR 16.6 12.0 329’ 302’ 5/16” EHS (1,120#) 277’ 3/16” EHS (399#) 255’ 1/4”EHS (665#) 142’ 116’ 96’ 88’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

208’

P/N: 55G110R260

ANCHORS & GROUNDING INCLUDED

110

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

20

1

1

5

3/16EHS

1/4EHS

142265

BG2142

BG2144

1750’

725’

825’

18

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

18

6

6

15

CB3G AB3

200’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 200

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

22

1

1

6

3/16EHS

1/4EHS

142265

BG2142

1925’

825’

900’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

6

6

6

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB4G AB2 BG2144

AB3 BG2146

220’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 220

6

6

12

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

55G

BPC55G

APL55G

24

1

1

7

3/16EHS

1/4EHS

142265

BG2142

1775’

1700’

975’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

12

6

9

3

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB4G AB2 BG2144

AB3 BG2146

240’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 240

12

6

12

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

2

55G

BPC55G

APL55G

26

1

1

7

3/16EHS

1/4EHS

142265

BG2142

BG2144

1500’

2300’

1050’

18

18

5/16THH

3/8THH

7/16THH

18

18

6

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB5G AB2

1/2TBE&J 5/8TBE&J 9

12

AB3 BG2146

260’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng TBSAFETY Par t No: 55G110R 260

6

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 275’ 241’ 207’ 173’ 139’ 105’ 71’ 35’

280’ TOWER 19.4 OR 16.4 355’ 329’ 305’ 283’ 264’ 134’ 110’ 91’

11.6

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

84’

GUYS & CONNECTIONS INCLUDED

224’

P/N: 55G110R280

ANCHORS & GROUNDING INCLUDED

295’ 259’ 223’ 187’ 151’ 115’ 79’ 41’

300’ TOWER 19.0 OR 16.1 380’ 353’ 328’ 304’ 284’ 152’ 127’ 108’

11.2

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

100’ 240’

P/N: 55G110R300

ANCHORS & GROUNDING INCLUDED

INNER OUTER GA55GD BASE ANCHOR ANCHOR

55G

BPC55G

APL55G

28

1

1

8

3/16EHS

1/4EHS

142265

BG2142

2825’

2025’

1150’

30

5/16THH

3/8THH

7/16THH

1/2TBE&J

30

12

6

9

CB5G AB2 BG2144

AB4 BG2146

280’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 280

12

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

2

55G

BPC55G

APL55G

30

1

1

8

3/16EHS

1/4EHS

142265

BG2142

1675’

2500’

2350’

18

5/16THH

3/8THH

7/16THH

1/2TBE&J

18

18

12

9

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB5G AB2 BG2144

AB4 BG2146

300’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 300

18

12

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

3

1

111


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 100’ TOWER 18.7 OR 14.6

95’

124’

18.0

5/16” EHS (1120#) 3/16” EHS (399#) 102’ 1/4” EHS (665#)

63’

33’

87’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

80’

P/N: 55G130R100

ANCHORS & GROUNDING INCLUDED 110’ TOWER 18.2 OR 14.2 16.0 137’ 5/16” EHS (1120#) 3/16” EHS (399#) 114’ 1/4” EHS (665#)

105’

72’

35’

95’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

88’

P/N: 55G130R110

ANCHORS & GROUNDING INCLUDED 120’ TOWER 17.7 OR 14.0 14.0 150’ 5/16” EHS (1120#) 3/16” EHS (399#) 123’ 1/4” EHS (665#)

115’

77’

38’

103’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

96’

P/N: 55G130R120

ANCHORS & GROUNDING INCLUDED 130’ TOWER 17.3 OR 13.8 12.0 163’ 5/16” EHS (1120#) 1/4” EHS (665#) 133’

125’

83’

42’

112’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

104’

P/N: 55G130R130

ANCHORS & GROUNDING INCLUDED

112

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

10

1

1

3

3/16EHS

1/4EHS

142265

BG2142

300’

325’

400’

6

BG2146

5/16THH

3/8THH

7/16THH

6

6

6

6

CB2G AB2 BG2144

100’ ROHN 55 G

All par ts shown in table are i nclu de d when order ing 1/2TBE&J 5/8TBE&J Par t No: 55G130R100

6

6

3

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

11

1

1

3

3/16EHS

1/4EHS

142265

BG2142

BG2144

325’

375’

450’

6

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

6

6

9

3

1

FDNS GA55GD BASE ANCHOR CB2G AB3

110’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R110

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

12

1

1

3

3/16EHS

1/4EHS

142265

BG2142

BG2144

350’

400’

500’

6

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

6

6

9

3

1

FDNS GA55GD BASE ANCHOR CB2G AB3

120’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R120

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

13

1

1

1/4EHS

142265

BG2144

BG2146

800’

525’

12

6

3/8THH

7/16THH

12

6

3

3

FDNS GA55GD BASE ANCHOR 3

CB2G AB3

130’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R130

5/8TBE&J TBSAFETY 9

1

3

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 3/4x12PP 3

1

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 135’ 101’ 67’ 34’

140’ TOWER 16.9 OR 13.6 11.0 175’ 5/16” EHS (1120#) 151’ 1/4” EHS (665#) 131’ 3/16” EHS (399#) 117’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

112’

P/N: 55G130R140

ANCHORS & GROUNDING INCLUDED

145’ 108’

150’ TOWER 16.6 OR 13.4 10.0 188’ 161’

72’ 36’

140’

TOWER PARTS INCLUDED

5/16” EHS (1120#) 1/4” EHS (665#) 3/16” EHS (399#)

125’

GUYS & CONNECTIONS INCLUDED

120’

P/N: 55G130R150

ANCHORS & GROUNDING INCLUDED

155’ 116’ 78’ 39’

160’ TOWER 16.3 OR 13.2 9.8 201’ 5/16” EHS (1120#) 173’ 1/4” EHS (665#) 150’ 3/16” EHS (399#) 134’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

128’

P/N: 55G130R160

ANCHORS & GROUNDING INCLUDED

165’ 124’ 83’ 41’

170’ TOWER 16.0 OR 13.0 9.6 214’ 5/16” EHS (1120#) 184’ 1/4” EHS (665#) 159’ 3/16” EHS (399#) 142’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

136’

P/N: 55G130R170

ANCHORS & GROUNDING INCLUDED

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

14

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

375’

900’

575’

6

12

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

12

6

3

CB3G AB3

140’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 140

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

15

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

400’

975’

600’

6

12

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

12

6

3

3

1

FDNS GA55GD BASE ANCHOR CB3G AB3

150’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 150

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

16

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

450’

1050’

650’

6

12

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

12

6

12

3

1

FDNS GA55GD BASE ANCHOR CB3G AB3

160’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 160

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

17

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

475’

1100’

700’

6

12

BG2146

5/16THH

3/8THH

7/16THH

3/4TBE&J

6

6

12

6

12

3

1

FDNS GA55GD BASE ANCHOR CB3G AB4

170’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 170

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

113


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 180’ TOWER 15.8 OR 12.9

175’

9.2 227’

142’

5/16” EHS (1120#) 202’ 1/4” EHS (665#) 178’ 3/16”EHS 161’ (399#)

105’ 72’ 35’

148’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

144’

P/N: 55G130R180

ANCHORS & GROUNDING INCLUDED 190’ TOWER 15.5 OR 12.7 9.0

185’

239’

152’

5/16” EHS (1120#) 215’ 1/4” EHS (665#) 191’

115’ 82’

173’

41’

157’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

152’

P/N: 55G130R190

ANCHORS & GROUNDING INCLUDED

114

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

18

1

1

5

3/16EHS

1/4EHS

142265

BG2142

BG2144

1000’

1225’

725’

12

12

BG2146

5/16THH

3/8THH

7/16THH

3/4TBE&J

6

12

12

6

15

CB3G AB4

180’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 180

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 1

3

1

3

3

3

55G

BPC55G

APL55G

GA55GD

BASE ANCHOR

19

1

1

5

1/4EHS

142265

BG2144

BG2146

190’ ROHN 55G

2350’

775’

24

6

3/8THH

7/16THH

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 190

24

6

FDNS

CB4G AB4

3/4TBE&J TBSAFETY 15

3

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 3/4x12PP 3

1

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 55G

PA R T S & A CC E S S O R I E S

TOP PLATE APL55G FOR MOUNTING BEACON OR LIGHTNING ROD.

BEARING PLATE BPL55G

ACCESSORY SHELF AS455G

CONVERTS STANDARD SECTION TO A TOP SECTION. HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARING.

FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.

TOP MOUNT 55TDMKD - NO MAST 55TDM2S3KD - 2 3/8” O.D. MAST 55TDM25S3KD - 2 7/8” O.D. MAST 55TDM3S3KD - 3 1/2” O.D. MAST 55TDM35S3KD - 4” O.D. MAST 55TDM4S3KD - 4 1/2” O.D. MAST MOUNTING TUBE PROVIDED IS 7’.

TAPERED BASE* 55TG - STANDARD 55TGIA - USE WITH A4197L BASE INSULATOR

CONCRETE BASE PLATE BPC55G* LIGHTNING ROD LRCL

5’ COPPER CLAD, MOUNTS TO APL55G.

FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. CONCRETE BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

PIER PIN 3/4X12PP

55TGIAA - USE WITH

A4722B BASE INSULATOR

FOR USE WITH BPC55G EMBEDDED IN CONCRETE.

INSULATOR AND PIER PIN MUST BE ORDERED SEPARATELY.

PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.

Adjustable 2.5’ - 3.0’

5’ SHORT BASE SB55G

FLAT ROOF MOUNT FR55G* BOLTS DIRECTLY TO FLAT ROOF SURFACE.

FOR EMBEDMENT IN CONCRETE.

SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.

FACE MOUNT DM55G2 - 2 3/8” O.D. 5’ LONG DM554 - 4 1/2” O.D. 5’ LONG

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

115


G

GUYED TOWERS - 55G

PA R T S & A CC E S S O R I E S

HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 18” - 36” FROM WALL.

TORQUE ARM STABILIZER ASSEMBLY TA55 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER.

THRUST BEARING TB3 - SUPPORTS UP TO 2” O.D. MAST. TB4 - SUPPORTS UP TO 3” O.D. MAST. MOUNTS TO BPL55G.

ANTI-CLIMB PANELS 455ACL3

TORQUE BAR TB55D

OPTIONAL, FOR USE WITH GA55GD. REQUIRES (1) 3/8” SHACKLE FOR EACH BAR.

WORK PLATFORM WP55G SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

GUY BRACKET GA55GD MOUNTS TO TOWER AT ANY HORIZONTAL BRACE.

SAFETY RING SR55 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.

SAFETY CABLE SYSTEM ORDERING INFORMATION

CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS

TTFBH-C/P

PROFESSIONAL HARNESS

116

SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC

TOWER HEIGHT 50’ 100’ 150’ 200’ 250’ 300’ 350’ 400’

PART NUMBER TT0504555 TT1004555 TT1504555 TT2004555 TT2504555 TT3004555 TT3504555 TT4004555

SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 55G

A N C H O R I N F O R M AT I O N 81”

12”

3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4”

4” x 4” x 3/8” angle

2”

GAC3455TOP

11/16”

120”

12”

1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4”

5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP 168”

12”

3/4” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 7/16”

5” x 5” x 3/8” angle

3” 15/16”

GAC5755TOP REV G BASE GROUNDING BGK2GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp Ground Wire Clamp

Ground Wire

Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed at 120o separation at 20’ spacing.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

117


G

GUYED TOWERS - 55G

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required

o

Top and bottom horizontal bars equally spaced

A B

C

D

Refer to page 119 for anchor rod installation angles.

118

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

Anchor Rod Angle

55G | 90MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’ 360’ 380’ 400’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 38 GAC5655TOP 40 GAC5655TOP 40 GAC5755TOP 38 GAC5755TOP 37 GAC3455TOP 43 GAC5655TOP 42 GAC3455TOP 42 GAC5655TOP 42 GAC3455TOP 39 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 38 GAC5655TOP 42

Ground Line

55G | 110MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 41 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 38 GAC5655TOP 38 GAC5655TOP 39 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC3455TOP 42 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 44 GAC3455TOP 41 GAC5655TOP 44 GAC3455TOP 40 GAC5655TOP 43 GAC3455TOP 39 GAC5655TOP 43

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

55G | 130MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Rod Rod Number Angle GAC3455TOP 41 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5755TOP 38 GAC5755TOP 38 GAC5755TOP 37

119


G

GUYED TOWERS - 55G

S TA N D A R D B A S E P I E R S Pier Pin 4” Projection 6”

Grade

(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps E

No. 4 Circular ties, 3” Max. O.C. with 24” laps Vertical re-bars equally spaced with 90 hooks at bottom (for CB5G)

D

Roughen construction joint to a full amplitude of 1/4”

C

Foundation Pad

F

Horizontal reinforcing steel bars equally spaced each way

ELEVATION VIEW B

A

B

Alternate Square Pier

No. 4 Circular ties, 3” O.C. with 24” laps CL

A

Vertical bars equally spaced

CL

PLAN VIEW

Base

120

A

B

C

D

E

F

Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier

Horiz. Bars in Pad (No. & Size)

CB1G* 2’ - 6” 2’ - 6” N/A 4’ - 0” N/A

N/A

1.0

(8) #7

NONE

CB2G

3’ - 0” 3’ - 0” N/A 4’ - 0” N/A

N/A

1.2

(10) #7

NONE

CB3G

3’ - 6” 3’ - 6” N/A 4’ - 0” N/A

N/A

1.6

(12) #7

NONE

CB4G

4’ - 0” 4’ - 0” N/A 4’ - 0” N/A

N/A

2.1

(12) #8

NONE

CB5G

2’ - 0” 4’ - 0” 1’ - 0” 4’ - 0” 3’ - 3” 1’ - 3”

1.1

(8) #6

(5) #5

(Total of 10)

* Square pier option must be used for CB1G. Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 65G

S TA N D A R D 6 5 G G U Y E D T O W E R

ROHN 65G The first. The original.

includes

REV. F & REV. G

65G

GENERAL USE The 65G is designed to provide excellent rigidity and strength in applications up to 500’. This high strength design covers a wide variety of communication uses. The 65G is completely pre-fabricated in welded sections, allowing for quick and convenient installation.

FEATURES • Completely hot-dip galvanized after fabrication • Built on a 24 1/4” equilateral triangle design • High strength tubular legs joined by Zig-Zag®

cross members • Each section contains all required nuts and bolts shipped with section • Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 142 for ordering information.

122

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D 6 5 G G U Y E D T O W E R SECTIONS 21”

14” “

QUICK REFERENCE PARTS & ACCESSORIES PAGES 141-142 GROUNDING INFORMATION PAGE 143 FOUNDATION INFORMATION PAGES 143-146

24 1/4”

Optional Waveguide Brackets (KY2041A)

1.90” O.D. (0.145” Wall)

1.90” O.D. (0.145” Wall)

5/8” O.D. Solid Bracing

5/8” O.D. Solid Bracing Optional double braced sections are available upon request.

TAPERED BASE 65TGH - 10’ Section

STANDARD SECTION 65G - 10’ Section 6520G - 20’ Section

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

123


G

GUYED TOWERS - 65G

BUYERS GUIDE S TA N D A R D D E S I G N S - 6 5 G 9 0 M P H R E V. G [ 3 S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 60.8

78.1

92’

EPA (SQ. FT.) For Exposure C, Revision G

68.0 122’

45’

92’

5/16” EHS (1,120#) 3/16” EHS (399#)

EPA (SQ. FT.), Revision F Guy Initial Tension

P/N 65G90R100 80’

P/N 65G90R100

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 65G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 7/8” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 143-146. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

124

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 100’ TOWER 78.0 OR 60.8

92’

68.0 122’ 5/16” EHS (1,120#)

45’

92’

3/16” EHS (399#)

80’

P/N: 65G90R100

100’

110’ TOWER 75.8 OR 59.6 66.2 133’ 5/16” EHS (1,120#)

52’

102’

3/16” EHS (399#)

88’

P/N: 65G90R110

112’

120’ TOWER 73.9 OR 58.5 64.8 148’ 5/16” EHS (1,120#)

55’

111’

3/16” EHS (399#)

96’

P/N: 65G90R120

120’

130’ TOWER 72.3 OR 57.3 63.4 159’ 5/16” EHS (1,120#)

60’

120’

3/16” EHS (399#)

104’

P/N: 65G90R130

129’

140’ TOWER 70.7 OR 56.6 62.2 171’ 3/16” EHS (399#)

86’ 141’ 43’

5/16”EHS (1,120#)

120’ 112’

P/N: 65G90R140

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

65G

65TGH

6520G

GA65GD

APL4HA

1

1

4

2

1

FDNS

BASE ANCHOR

CB2G AB2

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1/2TBE&J 400’

6

300’

6

6

6

3

3

100’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 100

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

65TGH

6520G

APL4HA

GA65GD

1

5

1

2

3

1

FDNS

BASE ANCHOR

CB2G AB2

110’ ROHN 65G

142265 3/16EHSBG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1/2TBE&J 425’

6

325’

6

6

6

3

3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 110

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

GA65GD

APL4HA

1

1

5

2

1

1 FDNS

BASE ANCHOR

CB2G AB2

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1/2TBE&J 475’

6

375’

6

6

6

3

3

120’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 120

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

65TGH

6520G

GA65GD

APL4HA

1

6

2

1

3

1

FDNS

BASE ANCHOR

CB2G AB2

130’ ROHN 65G

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1/2TBE&J 525’

6

400’

6

6

6

3

3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 130

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

6

1

3

1 FDNS

BASE ANCHOR

CB2G AB2

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1/2TBE&J 550’

12

850’

6

12

6

6

3

140’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 140

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

125


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 150’ TOWER 69.4 OR 55.8 61.0

138’

183’ 3/16” EHS (399#)

92’ 151’ 46’

5/16”EHS (1,120#)

129’ 120’

P/N: 65G90R150 160’ TOWER 67.8 OR 55.0 60.0

152’

199’ 3/16” EHS (399#)

100’ 162’ 52’

5/16”EHS (1,120#)

138’ 128’

P/N: 65G90R160 170’ TOWER 66.7 OR 54.3 59.0

159’

209’ 3/16” EHS (399#)

106’ 172’ 53’

5/16”EHS (1,120#)

146’ 136’

P/N: 65G90R170 180’ TOWER 65.6 OR 53.7 221’ 58.2 5/16”EHS (1,120#)

168’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

1/4” EHS (665#)

112’ 182’

3/16”EHS (399#) 56’

155’

GUYS & CONNECTIONS INCLUDED

144’

P/N: 65G90R180

ANCHORS & GROUNDING INCLUDED

126

65TGH

6520G

APL4HA

GA65GD

1

7

1

3

FDNS

BASE ANCHOR

CB2G AB2

150’ ROHN 65G

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1/2TBE&J 600’

12

900’

6

12

6

6

3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 150

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

7

1

3

1 FDNS

BASE ANCHOR

CB2G AB3

160’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 160

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 650’

12

975’

6

12

6

9

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

65TGH

6520G

APL4HA

GA65GD

1

8

1

3

3

1

FDNS

BASE ANCHOR

CB3G AB3

170’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 170

142265 3/16EHS BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 675’

12

1025’

6

12

6

9

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

8

1

3

142265

1/4EHS

3/16EHS

BG2142

BG2144

725’

600’

500’

6

6

BG2146

5/8TBE&J

7/16THH

3/8THH

5/16THH

6

9

6

6

6

1 FDNS

BASE ANCHOR

CB3G AB3

180’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 180

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 190’ TOWER 64.8 OR 53.1 236’ 57.2 5/16”EHS (1,120#)

180’

1/4” EHS (665#)

120’ 194’

3/16”EHS (399#) 60’

TOWER PARTS INCLUDED

163’

GUYS & CONNECTIONS INCLUDED

152’

P/N: 65G90R190

ANCHORS & GROUNDING INCLUDED

186’

200’ TOWER 63.8 OR 52.5 245’ 54.4 5/16”EHS (1,120#) 1/4” EHS (665#)

124’ 202’

3/16”EHS (399#) 62’

TOWER PARTS INCLUDED

172’

GUYS & CONNECTIONS INCLUDED

160’

P/N: 65G90R200

ANCHORS & GROUNDING INCLUDED

208’

220’ TOWER 62.1 OR 51.4 53.0 272’ 5/16” EHS (1,120#)

156’ 235’ 104’ 52’

204’

TOWER PARTS INCLUDED

1/4” EHS (665#) 3/16” EHS (399#)

184’

GUYS & CONNECTIONS INCLUDED

176’

P/N: 65G90R220

ANCHORS & GROUNDING INCLUDED

232’

240’ TOWER 60.6 OR 50.5 51.6 301’ 5/16” EHS (1,120#)

173’ 258’ 116’ 58’

224’

TOWER PARTS INCLUDED

1/4” EHS (665#) 3/16” EHS (399#)

201’

GUYS & CONNECTIONS INCLUDED

192’

P/N: 65G90R240

ANCHORS & GROUNDING INCLUDED

INNER GA65GD BASE ANCHOR

65TGH

6520G

APL4HA

1

9

1

3

CB3G AB3

190’ ROHN 65G

142265

1/4EHS

3/16EHS

BG2142

BG2144

750’

625’

525’

6

6

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 190

BG2146

5/8TBE&J

7/16THH

3/8THH

5/16THH

6

9

6

6

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

6

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

9

1

3

142265

1/4EHS

3/16EHS

BG2142

BG2144

800’

650’

550’

6

6

BG2146

5/8TBE&J

7/16THH

3/8THH

5/16THH

6

9

6

6

6

FDNS

CB3G AB3

200’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 200

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

10

1

4

142265

1/4EHS

3/16EHS

BG2142

BG2144

875’

750’

1250’

12

6

BG2146

5/8TBE&J

7/16THH

3/8THH

5/16THH

6

12

6

6

12

3

1 FDNS

BASE ANCHOR

CB3G AB3

220’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 220

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

11

1

4

142265

1/4EHS

3/16EHS

BG2142

BG2144

975’

825’

1375’

12

6

BG2146

5/8TBE&J

7/16THH

3/8THH

5/16THH

6

12

6

6

12

1 FDNS

BASE ANCHOR

CB3G AB3

240’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 240

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

127


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 248’

260’ TOWER 59.2 OR 49.7 50.4 324’ 3/8” EHS (1,540#)

186’ 279’ 124’

242’

1/4” EHS (665#) 3/16” EHS (399#)

217’

62’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

208’

P/N: 65G90R260

ANCHORS & GROUNDING INCLUDED

272’ 216’

280’ TOWER 58.0 OR 48.9 49.4 352’ 3/8” EHS (1,540#)

TOWER PARTS INCLUDED

311’

162’

276’

108’

249’

54’

230’

1/4” EHS (665#) 3/16”EHS (399#)

GUYS & CONNECTIONS INCLUDED

224’

P/N: 65G90R280

ANCHORS & GROUNDING INCLUDED 300’ TOWER 56.8 OR 48.2 48.4

292’

378’ 3/8” EHS (1,540#)

232’

TOWER PARTS INCLUDED

334’ 174’

296’

116’

267’

58’

247’

5/16” EHS (1,120#) 1/4” EHS (665#) 3/16”EHS (399#) 240’

P/N: 65G90R300

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

128

65G

65TGH

6520G

APL4HA

GA65GD

1

1

12

1

4

142265

1/4EHS

3/16EHS

BG2142

BG2144

1050’

1675’

700’

6

12

BG2147

5/8TBE&J

1/2THH

3/8THH

5/16THH

6

12

6

12

6

FDNS

BASE ANCHOR

CB4G AB4

260’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 260

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

13

1

5

142265

1/4EHS

3/16EHS

BG2142

BG2144

1125’

1875’

1550’

12

12

BG2147

5/8TBE&J

1/2THH

3/8THH

5/16THH

6

15

6

12

12

3

1 FDNS

BASE ANCHOR

CB4G AB4

280’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 280

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

14

1

5

142261

142265

1/4EHS

3/16EHS

BG2142

1225’

1075’

1800’

800’

6

300’ ROHN 65G

BG2144

BG2146

BG2147

5/8TBE&J

1/2THH

12

6

6

15

6

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 300

7/16THH

3/8THH

5/16THH

TBSAFETY

6

12

6

3

1 FDNS

BASE ANCHOR

CB4G AB4

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 15/16x16PP 3

1

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 312’ 248’ 186’ 124’ 62’

320’ TOWER 55.8 OR 47.5 47.6 3/8” EHS 356’ (1,540#) 5/16” EHS (1,120#) 316’ 1/4”EHS (665#) 404’

284’ 263’

3/16”EHS (399#) 256’

P/N: 65G90R320

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

ANCHORS & GROUNDING INCLUDED

332’ 275’ 220’ 165’ 112’ 55’

340’ TOWER 54.8 OR 46.9 46.6 429’ 3/8” EHS (1,540#) 387’ 5/16” EHS (1,120#) 350’ 1/4” EHS (665#) 318’ 3/16”EHS (399#) 142’ 104’ 88’

272’

P/N: 65G90R340

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

65G

65TGH

6520G

APL4HA

GA65GD

1

1

15

1

5

142261

142265

1/4EHS

3/16EHS

BG2142

1300’

1150’

1925’

850’

6

BG2144

BG2146

BG2147

5/8TBE&J

1/2THH

12

6

6

15

6

7/16THH

3/8THH

6

12

FDNS

BASE ANCHOR

CB5G AB4

320’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 320

5/16THH TBSAFETY 6

3

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 15/16x16PP 3

1

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

1

1

16

1

6

142261

142265

1/4EHS

3/16EHS

BG2142

1375’

1250’

2600’

350’

6

BG2144

BG2146

BG2147

18

6

6

12

1/2THH

7/16THH

3/8THH

5/16THH

6

6

18

6

INNER OUTER BASE ANCHOR ANCHOR

CB5G AB2

AB4

340’ ROHN 65G

5/8TBE&J 1/2TBE&J

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 340

6

GAC5655TOP GAC3455TOP AGK1GGX BGK2GGX ANCHORS & GROUNDING INCLUDED

352’ 292’ 234’ 176’ 118’ 59’

360’ TOWER 53.9 OR 46.4 45.8 455’ 3/8” EHS (1,540#) 410’ 5/16” EHS (1,120#) 371’ 1/4” EHS (665#) 338’ 151’ 111’ 94’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

288’

P/N: 65G90R360

3

3

2

3

CPC.5/.75 CPC1/1.25 TBSAFETY 15/16x16PP 3

3

6

1

65G

65TGH

6520G

APL4HA

GA65GD

1

1

17

1

6

142261

142265

1/4EHS

1450’

1325’

3100’

12

6

BG2144

BG2146

BG2147

1/2THH

7/16THH

24

6

6

6

6

5/8TBE&J 1/2TBE&J

INNER OUTER BASE ANCHOR ANCHOR

CB6G AB2 3/8THH

GAC5655TOP GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 ANCHORS & GROUNDING INCLUDED

3

3

2

3

AB4

3

24

360’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 360

CPC1/1.25 APL1258UM TBSAFETY 15/16x16PP 3

2

6

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

129


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 372’ 309’ 248’

380’ TOWER 53.1 OR 45.8 480’ 45.2 3/8” EHS 433’ (1,540#) 5/16” EHS (1,120#) 392’

187’ 357’

125’

1/4” EHS (665#)

160’ 118’

63’

100’

304’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

P/N: 65G90R380

65G

65TGH

6520G

APL4HA

GA65GD

1

1

18

1

6

INNER OUTER BASE ANCHOR ANCHOR

CB6G AB2

5/8TBE&J 1/2TBE&J

142261

142265

1/4EHS

1550’

1400’

3300’

12

6

BG2144

BG2146

BG2147

1/2THH

7/16THH

24

6

6

6

6

3/8THH 24

392’ 334’ 278’ 222’ 166’ 112’ 55’

400’ TOWER 52.3 OR 45.3 44.4 506’ 3/8” EHS 463’ (1,540#) 5/16” EHS (1,120#) 424’ 1/4” EHS 389’ (665#) 213’ 174’ 144’ 133’

320’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

P/N: 65G90R400

3

3

2

3

380’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 380

GAC5655TOP GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 ANCHORS & GROUNDING INCLUDED

AB4

3

CPC1/1.25 APL1258UM TBSAFETY 15/16x16PP 3

2

6

1

65G

65TGH

6520G

APL4HA

GA65GD

1

1

19

1

7

142261

142265

1/4EHS

1625’

1475’

4300’

12

9

BG2144

BG2146

BG2147

1/2THH

7/16THH

30

6

6

6

6

5/8TBE&J 1/2TBE&J

INNER OUTER BASE ANCHOR ANCHOR

CB6G AB2

AB4

3/8THH 30

400’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 400

GAC5655TOP GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 ANCHORS & GROUNDING INCLUDED

412’ 352’ 294’

420’ TOWER 51.6 OR 44.9 43.8 532’ 3/8” EHS 487’ (1,540#) 446’ 411’

236’ 177’ 118’ 59’

227’ 185’ 154’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#) 142’

336’

GUYS & CONNECTIONS INCLUDED

P/N: 65G90R420

3

3

2

3

3

CPC1/1.25 APL1258UM TBSAFETY 15/16x16PP 3

2

6

1

65G

65TGH

6520G

APL4HA

GA65GD

1

1

20

1

7

142261

142265

1/4EHS

5/8TBE&J

3/8THH

1700’

5025’

1100’

21

12

BG2144

BG2146

BG2147

1/2THH

7/16THH

12

24

6

6

24

INNER OUTER BASE ANCHOR ANCHOR

CB6G AB3

AB4

420’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 420

GAC5655TOP APL1258UM AGK1GGX BGK2GGX CPC1/1.25 ANCHORS & GROUNDING INCLUDED

6

2

3

6

TBSAFETY 15/16x16PP 6

130

2

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 440’ TOWER 50.9 OR 44.4 43.2 554’ 3/8” EHS 509’ (1,540#) 5/16” EHS (1,120#) 468’ 431’

428’ 368’ 308’ 248’ 188’ 126’ 63’

241’ 196’ 163’

1/4” EHS (665#) 150’

352’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

P/N: 65G90R440

65G

65TGH

6520G

APL4HA

GA65GD

1

1

21

1

7

142261

142265

1/4EHS

5/8TBE&J

3/8THH

1775’

5275’

1150’

21

12

BG2144

BG2146

BG2147

1/2THH

7/16THH

12

24

6

6

24

INNER OUTER BASE ANCHOR ANCHOR

CB7G AB3

AB4

440’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 440

GAC5655TOP APL1258UM AGK1GGX BGK2GGX CPC1/1.25 ANCHORS & GROUNDING INCLUDED

448’ 392’ 336’ 280’ 224’ 168’ 112’ 56’

460’ TOWER 50.3 OR 44.0 580’ 42.6 3/8” EHS 538’ (1,540#) 498’ 462’ 431’ 215’ 175’ 146’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#) 134’

GUYS & CONNECTIONS INCLUDED

368’

P/N: 65G90R460

6

2

2

3

6

TBSAFETY 15/16x16PP 6

1

65G

65TGH

6520G

APL4HA

GA65GD

1

1

22

1

8

142261

142265

1/4EHS

1850’

6850’

1025’

15

9

BG2144

BG2146

BG2147

1/2THH

7/16THH

12

30

6

6

30

3/4TBE&J 5/8TBE&J

INNER OUTER BASE ANCHOR ANCHOR

CB7G AB3 3/8THH 12

460’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 460

GAC5655TOP GAC5755TOP AGK1GGX BGK2GGX CPC1/1.25 ANCHORS & GROUNDING INCLUDED

472’ 413’ 354’ 295’ 236’ 177’ 118’ 59’

480’ TOWER 49.7 OR 43.6 609’ 42.0 3/8” EHS 564’ (1,540#) 522’ 484’ 451’ 227’ 185’ 154’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#) 142’

384’

GUYS & CONNECTIONS INCLUDED

P/N: 65G90R480

3

3

2

3

3

CPC1.5/2 APL1258UM TBSAFETY 15/16x16PP 3

2

6

1

65G

65TGH

6520G

APL4HA

GA65GD

1

1

23

1

8

142261

142265

1/4EHS

1950’

7175’

1100’

15

9

BG2144

BG2146

BG2147

1/2THH

7/16THH

12

30

6

6

30

3/4TBE&J 5/8TBE&J

INNER OUTER BASE ANCHOR ANCHOR

CB7G AB3

3

3

2

3

AB5

3/8THH

GAC5655TOP GAC5755TOP AGK1GGX BGK2GGX CPC1/1.25 ANCHORS & GROUNDING INCLUDED

AB5

3

12

480’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 480

CPC1.5/2 APL1258UM TBSAFETY 15/16x16PP 3

2

6

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

131


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 488’ 427’ 366’ 305’ 244’

500’ TOWER 49.1 OR 43.3 631’ 41.6 585’ 3/8” EHS (1,540#) 542’ 503’ 469’

183’ 122’ 61’

237’ 193’ 162’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 1/4” EHS (665#) 150’

GUYS & CONNECTIONS INCLUDED

400’

P/N: 65G90R500

65G

65TGH

6520G

APL4HA

GA65GD

1

1

24

1

8

142261

142265

1/4EHS

2025’

7450’

1150’

15

9

BG2144

BG2146

BG2147

1/2THH

7/16THH

12

30

6

6

30

3/4TBE&J 5/8TBE&J

GAC5655TOP GAC5755TOP AGK1GGX BGK2GGX CPC1/1.25 ANCHORS & GROUNDING INCLUDED

3

2

3

CB7G AB3

AB5

3/8THH 12

500’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G90R 500

3

CPC1.5/2 APL1258UM TBSAFETY 15/16x16PP 3

132

3

INNER OUTER BASE ANCHOR ANCHOR

2

6

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 100’ TOWER 52.2 OR 40.7

92’

24.2 122’ 5/16” EHS (1,120#)

45’

92’

1/4” EHS (665#)

80’

P/N: 65G110R100 110’ TOWER 50.8 OR 39.9

100’

23.6 133’ 5/16” EHS (1,120#)

52’

102’

1/4” EHS (665#)

88’

P/N: 65G110R110

112’

120’ TOWER 49.5 OR 39.2 22.8 148’ 5/16” EHS (1,120#)

55’

111’

1/4” EHS (665#)

96’

P/N: 65G110R120 130’ TOWER 48.4 OR 38.5

120’

22.2 159’ 3/8” EHS (1,540#)

60’

120’

1/4” EHS (665#)

104’

P/N: 65G110R130

129’

140’ TOWER 47.2 OR 37.9 21.6 171’ 5/16”EHS (1,120#)

GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

3/16” EHS (399#)

86’ 141’ 43’

TOWER PARTS INCLUDED

1/4”EHS (665#)

120’

GUYS & CONNECTIONS INCLUDED

112’

P/N: 65G110R140

ANCHORS & GROUNDING INCLUDED

65G

65TGH

6520G

APL4HA

1

1

4

1

GA65GD BASEFDNS ANCHOR 2

CB2G AB2

142265 1/4EHS BG2144 BG2146 7/16THH 3/8THH 5/8TBE&J 1/2TBE&J 400’

6

300’

6

6

6

3

3

100’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G110R 100

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

65TGH

6520G

APL4HA

1

5

1

3

3

1

GA65GD BASEFDNS ANCHOR 2

CB2G AB2

110’ ROHN 65G Al l par ts shown i n

142265 1/4EHS BG2144 BG2146 7/16THH 3/8THH 5/8TBE&J 1/2TBE&J tabl e are i nc l uded 425’

6

325’

6

6

6

3

3

when order i ng Par t No: 65G110R 110

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 15/16x16PP 3

1

3

3

65G

65TGH

6520G

APL4HA

1

1

5

1

3

1

GA65GD BASEFDNS ANCHOR 2

CB2G AB3

142265 1/4EHS BG2144 BG2146 7/16THH 3/8THH 5/8TBE&J 475’

6

375’

6

6

6

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

65TGH

6520G

APL4HA

1

6

1

3

3

6

400’

6

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G110R 120

1

GA65GD BASEFDNS ANCHOR 2

CB2G AB3

130’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G110R 130

142261 1/4EHS BG2147 BG2144 1/2THH 3/8THH 5/8TBE&J 525’

120’ ROHN 65G

6

6

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

6

1

3

142265

1/4EHS

3/16EHS

BG2142

BG2144

550’

450’

400’

6

6

BG2146

5/8TBE&J

7/16THH

3/8THH

5/16THH

6

9

6

6

6

FDNS

CB3G AB3

140’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G110R 140

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

133


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 150’ TOWER 46.4 OR 37.3 183’ 21.2 3/8”EHS (1,540#) 3/16” EHS (399#)

138’

92’

151’ 46’

1/4”EHS (665#)

129’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

6520G

APL4HA

GA65GD

1

7

1

3

CB3G AB3

150’ ROHN 65G

142261

1/4EHS

3/16EHS

BG2142

BG2144

600’

500’

425’

6

6

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 150

BG2147

5/8TBE&J

1/2THH

3/8THH

5/16THH

6

9

6

6

6

120’

P/N: 65G110R150

ANCHORS & GROUNDING INCLUDED 160’ TOWER 45.6 OR 36.8 20.6 199’ 3/8”EHS (1,540#) 3/16” EHS (399#)

152’

100’

162’ 52’

1/4”EHS (665#)

138’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

128’

P/N: 65G110R160

ANCHORS & GROUNDING INCLUDED 170’ TOWER 44.8 OR 36.4 209’ 20.2

159’

3/8”EHS (1,540#) 106’ 172’ 53’

1/4”EHS (665#)

146’ 136’

P/N: 65G110R170 180’ TOWER 44.1 OR 35.9 19.8 221’

168’

3/8” EHS (1,540#)

112’ 182’

1/4”EHS (665#) 56’

155’ 144’

P/N: 65G110R180

134

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

FDNS

65TGH

BASE ANCHOR

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

6

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

7

1

3

142261

1/4EHS

3/16EHS

BG2142

BG2144

650’

525’

450’

6

6

BG2147

5/8TBE&J

1/2THH

3/8THH

5/16THH

6

9

6

6

6

FDNS

CB3G AB3

160’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 160

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

65TGH

6520G

APL4HA

1

8

1

3

3

1

GA65GD BASE FDNS ANCHOR 3

170’ ROHN 65G

CB3G AB3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 170

142261 1/4EHS BG2144 BG2147 1/2THH 3/8THH 5/8TBE&J 675’

12

1025’

6

6

12

9

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

8

1

3

FDNS

CB3G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G110R 180

142261 1/4EHS BG2144 BG2147 1/2THH 3/8THH 5/8TBE&J 725’

12

1075’

6

6

12

180’ ROHN65G

9

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 190’ TOWER 43.4 OR 35.5 236’ 19.4 3/8”EHS (1,540#)

180’

5/16” EHS (1,120#)

120’ 194’

1/4”EHS (665#) 60’

TOWER PARTS INCLUDED

163’

GUYS & CONNECTIONS INCLUDED

152’

P/N: 65G110R190

ANCHORS & GROUNDING INCLUDED 200’ TOWER 42.7 OR 35.1 17.0 245’ 3/8”EHS (1,540#) 5/16”EHS (1,120#) 202’ 1/4”EHS (665#) 172’

186’

124’

62’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

160’

P/N: 65G110R200

ANCHORS & GROUNDING INCLUDED 220’ TOWER 41.6 OR 34.4 16.4 272’ 3/8” EHS (1,540#)

208’ 156’

235’ 104’

204’

5/16” EHS (1,120#) 1/4” EHS (665#)

184’

52’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

176’

P/N: 65G110R220

ANCHORS & GROUNDING INCLUDED

232’

240’ TOWER 40.6 OR 33.8 15.8 301’ 3/8” EHS (1,540#)

173’ 116’ 58’

258’

5/16” EHS (1,120#)

224’

1/4” EHS (665#)

201’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

192’

P/N: 65G110R240

ANCHORS & GROUNDING INCLUDED

FDNS

65TGH

6520G

APL4HA

GA65GD

1

9

1

3

CB4G AB4

142261

142265

1/4EHS

BG2144

BG2146

750’

625’

525’

6

6

BG2147

5/8TBE&J

1/2THH

7/16THH

3/8THH

6

9

6

6

6

BASE ANCHOR

190’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 190

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

6

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

9

1

3

142261

142265

1/4EHS

BG2144

BG2146

800’

650’

550’

6

6

BG2147

5/8TBE&J

1/2THH

7/16THH

3/8THH

6

9

6

6

6

FDNS

CB4G AB4

200’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 200

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

10

1

4

142261

142265

1/4EHS

BG2144

BG2146

875’

750’

1250’

12

6

BG2147

5/8TBE&J

1/2THH

7/16THH

3/8THH

6

12

6

6

12

1 FDNS

BASE ANCHOR

CB4G AB4

220’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 220

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

11

1

4

142261

142265

1/4EHS

BG2144

BG2146

975’

825’

1375’

12

6

BG2147

5/8TBE&J

1/2THH

7/16THH

3/8THH

6

12

6

6

12

1 FDNS

BASE ANCHOR

CB4G AB4

240’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 240

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

135


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 260’ TOWER 39.6 OR 33.2 15.2 248’ 324’ 3/8” EHS (1,540#) 186’ 279’ 124’

242’ 217’

62’

5/16” EHS (1,120#) 1/4”EHS (665#)

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

208’

P/N: 65G110R260

ANCHORS & GROUNDING INCLUDED

272’ 216’

280’ TOWER 38.8 OR 32.7 14.8 352’ 3/8” EHS (1,540#) 5/16” EHS 311’ (1,120#) 1/4” EHS (665#) 276’

162’ 108’

249’

54’

230’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

224’

P/N: 65G110R280

ANCHORS & GROUNDING INCLUDED 300’ TOWER 38.0 OR 32.3 14.4 378’ 3/8” EHS (1,540#)

292’ 232’

334’

174’

296’

116’

267’ 247’

58’

5/16” EHS (1,120#) 1/4” EHS (665#)

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

240’

P/N: 65G110R300

ANCHORS & GROUNDING INCLUDED

312’

320’ TOWER 37.3 OR 31.8 404’ 14.0

248’ 186’ 124’ 62’

3/8” EHS 356’ (1,540#) 5/16”EHS (1,120#) 316’ 284’ 263’

1/4”EHS (665#)

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

256’

P/N: 65G110R320

ANCHORS & GROUNDING INCLUDED

136

65G

65TGH

6520G

APL4HA

GA65GD

1

1

12

1

4

142261

142265

1/4EHS

BG2144

1/2THH

1050’

1675’

700’

6

6

7/16THH

3/4TBE&J

3/8THH

BG2146

BG2147

12

12

6

12

6

GAC5755TOP AGK1GGX BGK2GGX

CB5G AB5

260’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 260

CPC1.5/2 TBSAFETY 15/16x16PP

3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

13

1

5

142261

142265

1/4EHS

BG2144

BG2146

1125’

1000’

2450’

18

6

BG2147

7/16THH

3/4TBE&J

3/8THH

1/2THH

6

6

15

18

6

GAC5755TOP AGK1GGX BGK2GGX

FDNS

BASE ANCHOR

1 FDNS

BASE ANCHOR

CB5G AB5

280’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 280

CPC1.5/2 TBSAFETY 15/16x16PP

3

1

3

6

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

14

1

5

142261

142265

1/4EHS

BG2144

BG2146

1225’

2875’

800’

6

18

BG2147

3/4TBE&J

1/2THH

7/16THH

3/8THH

6

15

6

18

6

1 FDNS BASE ANCHOR

CB5G AB5

300’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 300

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 15/16x16PP 3

1

3

3

3

65G

65TGH

6520G

APL4HA

GA65GD

1

1

15

1

5

142261

142265

1/4EHS

BG2144

BG2146

2425’

1925’

850’

6

12

BG2147

3/4TBE&J

1/2THH

7/16THH

3/8THH

12

15

12

12

6

1 FDNS

BASE ANCHOR

CB6G AB6

320’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 320

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 15/16x16PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 332’ 275’ 220’

340’ TOWER 36.7 OR 31.4 429’ 13.6 3/8” EHS 387’ (1,540#) 5/16” EHS (1,120#) 350’

165’ 112’ 55’

318’ 142’ 104’

1/4”EHS (665#) 88’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

272’

P/N: 65G110R340

INNER OUTER GA65GD BASE ANCHOR ANCHOR

65G

65TGH

6520G

APL4HA

1

1

16

1

6

142261

142265

1/4EHS

BG2144

BG2146

BG2147

2600’

2600’

350’

6

18

12

3/4TBE&J

5/8TBE&J

1/2THH

7/16THH

3/8THH

12

6

12

18

6

CB7G AB3

GAC5655TOP GAC5755TOP AGK1GGX BGK2GGX ANCHORS & GROUNDING INCLUDED

3

3

2

AB5

340’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G110R 340

3

CPC1/1.25 CPC1.5/2 TBSAFETY 15/16x16PP 3

3

6

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

137


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 100’ TOWER 32.5 OR 25.4

92’

12.4 122’ 5/16” EHS (1,120#)

45’

92’

1/4” EHS (665#)

80’

P/N: 65G130R100 110’ TOWER 31.6 OR 24.8

100’

11.8 133’ 3/8” EHS (1,540#)

50’

101’

1/4” EHS (665#)

88’

P/N: 65G130R110 120’ TOWER 30.8 OR 24.4

112’

11.4 148’ 3/8” EHS (1,540#)

55’

111’

5/16” EHS (1,120#)

96’

P/N: 65G130R120 130’ TOWER 30.1 OR 24.0

120’

11.0 159’ 3/8” EHS (1,540#)

60’

120’

5/16” EHS (1,120#)

104’

P/N: 65G130R130 140’ TOWER 29.5 OR 23.6

129’

171’ 86’

10.6 3/8”EHS (1,540#) 5/16” EHS (1,120#)

141’ 43’

3/16”EHS (399#)

120’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

112’

P/N: 65G130R140

ANCHORS & GROUNDING INCLUDED

138

65G

65GTH

6520G

GA65GD

APL4HA

1

1

4

2

1

FDNS

BASE ANCHOR

CB2G AB3

142265 1/4EHS BG2146 BG2144 5/8TBE&J 3/8THH 7/16THH 400’

6

300’

6

6

6

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

65TGH

6520G

APL4HA

GA65GD

1

5

1

2

3

6

325’

6

6

FDNS

BASE ANCHOR

CB2G AB3

110’ ROHN 65G

6

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

5

1

2

6

375’

6

6

6

CB3G AB3

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

65TGH

6520G

APL4HA

GA65GD

1

6

1

2

3

6

400’

6

6

120’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G130R 120

1

FDNS

BASE ANCHOR

CB3G AB3

130’ ROHN 65G

142261 142265 BG2147 BG2146 7/16THH 1/2THH 5/8TBE&J 525’

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G130R 110

FDNS

142261 142265 BG2147 BG2146 7/16THH 1/2THH 5/8TBE&J 475’

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G130R 100

1

142261 1/4EHS BG2147 BG2144 1/2THH 3/8THH 5/8TBE&J 425’

100’ ROHN 65G

6

6

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

6

1

3

142261

142265

3/16EHS

BG2147

BG2146

550’

450’

400’

6

6

BG2142

5/8TBE&J

1/2THH

7/16THH

5/16THH

6

9

6

6

6

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G130R 130

FDNS

CB3G AB3

140’ ROHN 65G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G130R 140

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 65G

G

S TA N D A R D D E S I G N - 6 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 150’ TOWER 28.9 OR 23.3 10.2 183’ 3/8”EHS (1,540#) 5/16” EHS (1,120#)

138’

92’

151’ 46’

3/16”EHS (399#)

129’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

120’

P/N: 65G130R150

ANCHORS & GROUNDING INCLUDED

152’

100’

160’ TOWER 28.4 OR 22.9 9.8 199’ 3/8”EHS (1,540#) 5/16” EHS (1,120#) 162’

52’

1/4”EHS (665#)

138’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

128’

P/N: 65G130R160

ANCHORS & GROUNDING INCLUDED 170’ TOWER 27.8 OR 22.7 9.6 209’ 3/8”EHS (1,540#) 5/16” EHS (1,120#)

159’

106’

172’ 53’

1/4”EHS (665#)

146’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

136’

P/N: 65G130R170

ANCHORS & GROUNDING INCLUDED

168’

180’ TOWER 27.4 OR 22.4 9.4 221’ 3/8”EHS (1,540#) 5/16” EHS (1,120#)

112’ 182’ 56’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

155’ 144’

P/N: 65G130R180

ANCHORS & GROUNDING INCLUDED

FDNS

65TGH

6520G

APL4HA

GA65GD

1

7

1

3

CB3G AB4

142261

142265

3/16EHS

BG2147

BG2146

600’

500’

425’

6

6

BG2142

5/8TBE&J

1/2THH

7/16THH

5/16THH

6

9

6

6

6

BASE ANCHOR

150’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G130R 150

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

7

1

3

142261

142265

1/4EHS

BG2147

BG2146

650’

525’

450’

6

6

BG2144

5/8TBE&J

1/2THH

7/16THH

3/8THH

6

9

6

6

6

FDNS

CB4G AB4

160’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G130R 160

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

3

1

3

3

65TGH

6520G

APL4HA

GA65GD

1

8

1

3

CB4G AB4

142261

142265

1/4EHS

BG2147

BG2146

170’ ROHN 65G

675’

550’

475’

6

6

BG2144

5/8TBE&J

1/2THH

7/16THH

3/8THH

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G130R 170

6

9

6

6

6

1

FDNS

BASE ANCHOR

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

65G

65TGH

6520G

APL4HA

GA65GD

BASE ANCHOR

1

1

8

1

3

142261

142265

BG2147

BG2146

725’

1075’

6

12

5/8TBE&J

1/2THH

9

6

FDNS

CB4G AB4

180’ ROHN 65G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 65G90R 180

7/16THH TBSAFETY 12

3

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 15/16x16PP 3

1

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

139


G

GUYED TOWERS - 65G

S TA N D A R D D E S I G N - 6 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 190’ TOWER 27.0 OR 22.1 236’ 9.0 3/8”EHS (1,540#)

180’

5/16” EHS (1,120#)

120’ 194’ 60’

163’ 152’

P/N: 65G130R190

140

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

65TGH

6520G

APL4HA

GA65GD

1

9

1

3

FDNS

BASE ANCHOR

190’ ROHN 65G

CB4G AB4

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 65G130R 190

142261 142265 BG2147 BG2146 7/16THH 1/2THH 5/8TBE&J 750’

6

1150’

12

12

6

9

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 15/16x16PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 65G

PA R T S & A CC E S S O R I E S LIGHTNING ROD LRCL

5’ COPPER CLAD ORDERED SEPARATELY.

LEG MOUNTED BEACON PLATE KIT APL4HA FOR MOUNTING BEACON OR LIGHTNING ROD. BOLTS TO TOP OF STANDARD SECTION. INCLUDES BEACON PLATE, (2) CAP PLATES, NUTS AND BOLTS.

LIGHTNING ROD PLATE KIT VW133

INCLUDES: LIGHTNING ROD PLATE, (2) CAP PLATES, NUTS AND BOLTS.

CAP PLATE KIT CP4A

10’ TAPERED BASE 65TGH*

(3) CAP PLATES WITH NUTS AND BOLTS.

FOR USE WITH 15/16X16PP, ORDERED SEPARATELY.

Tie-Back Angle with 9/16” dia. holes, included with DM654TB.

Adjustable 2.5’ - 3.0’

PIER PIN 15/16X16PP FOR USE WITH 65TGH EMBEDDED IN CONCRETE. PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.

5’ SHORT BASE SB65GH

FOR EMBEDMENT IN CONCRETE.

FACE DISH MOUNT DM654

SIDE ARM ASSEMBLY SA253UA

MOUNTING TUBE PROVIDED IS 3’ LONG, 2 1/4” O.D.

4 1/2” O.D. X 5’ LONG

DM654TB

4 1/2” O.D. X 5’ LONG WITH TIE-BACK ANGLE.

6.2’

DISH MOUNT KY509 - 2 3/8” O.D. MAST KY510 - 4 1/2” O.D. MAST

MOUNTING TUBE PROVIDED IS 5’ LONG.

3’ SIDE ARM KH6100A

MOUNTING TUBE PROVIDED IS 7’ LONG, 2 3/8” O.D.

6’ SIDE ARM KY1048A

MOUNTING TUBE PROVIDED IS 5’ LONG, 2 3/8” O.D.

HOUSE BRACKET KH1014

ADJUSTABLE TO POSITION 65G 18” - 30” FROM WALL.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

141


G

GUYED TOWERS - 65G

PA R T S & A CC E S S O R I E S

GUY BRACKET ASSEMBLY GA65GD KIT INCLUDES (3) BRACKETS WITH U-BOLTS.

SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC

142

ANTI-CLIMB PANELS VW915A THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.

WORK PLATFORM WPCC65 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS

TTFBH-C/P

PROFESSIONAL HARNESS

SAFETY CABLE SYSTEM ORDERING INFORMATION TOWER PART HEIGHT NUMBER 50’ TT05065 100’ TT10065 150’ TT15065 200’ TT20065 250’ TT25065 300’ TT30065 350’ TT35065 400’ TT40065 450’ TT45065 500’ TT50065 SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 65G

A N C H O R I N F O R M AT I O N 81”

12”

3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4”

4” x 4” x 3/8” angle

2”

GAC3455TOP

11/16”

120”

12”

1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4”

5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP 168”

12”

3/4” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 7/16”

5” x 5” x 3/8” angle

3” 15/16”

GAC5755TOP REV G BASE GROUNDING BGK2GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp Ground Wire Clamp

Ground Wire

Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed o at 120 separation at 20’ spacing.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

143


G

GUYED TOWERS - 65G

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required Top and bottom horizontal bars equally spaced

o

A B

C

D

Refer to page 145 for anchor rod installation angles.

144

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 65G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

65G | 90MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’ 360’ 380’ 400’ 420’ 440’ 460’ 480’ 500’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 44 GAC3455TOP 44 GAC3455TOP 44 GAC3455TOP 44 GAC3455TOP 42 GAC3455TOP 42 GAC5655TOP 42 GAC5655TOP 41 GAC5655TOP 41 GAC5655TOP 41 GAC5655TOP 41 GAC5655TOP 40 GAC5655TOP 39 GAC5655TOP 39 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC3455TOP 43 GAC5655TOP 43 GAC3455TOP 43 GAC5655TOP 43 GAC3455TOP 43 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 44 GAC5655TOP 40 GAC5655TOP 43 GAC5655TOP 40 GAC5655TOP 43 GAC5655TOP 40 GAC5755TOP 42 GAC5655TOP 40 GAC5755TOP 42 GAC5655TOP 39 GAC5755TOP 42

Ground Line

Anchor Rod Angle

65G | 130MPH

65G | 110MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 44 GAC3455TOP 43 GAC5655TOP 42 GAC5655TOP 42 GAC5655TOP 41 GAC5655TOP 41 GAC5655TOP 41 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 39 GAC5655TOP 39 GAC5655TOP 38 GAC5755TOP 38 GAC5755TOP 37 GAC5755TOP 37 GAC5755TOP 37 GAC5655TOP 43 GAC5755TOP 42

Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

Rod Rod Number Angle GAC5655TOP 42 GAC5655TOP 42 GAC5655TOP 41 GAC5655TOP 41 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 39 GAC5655TOP 38 GAC5655TOP 38

145


G

GUYED TOWERS - 65G

S TA N D A R D B A S E P I E R S Pier Pin 4” Projection 6”

Grade

(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps E

No. 4 Circular ties, 3” Max. O.C. with 24” laps Vertical re-bars equally spaced with 90 hooks at bottom (for CB5G - CB7G)

D

Roughen construction joint to a full amplitude of 1/4”

C

Foundation Pad

F

Horizontal reinforcing steel bars equally spaced each way

ELEVATION VIEW B

A

Alternate Square Pier

A

B

No. 4 Circular ties, 3” O.C. with 24” laps CL Vertical bars equally spaced

CL

PLAN VIEW

Base

146

A

B

C

D

F

E

Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier

Horiz. Bars in Pad (No. & Size)

CB2G

3’ - 0” 3’ - 0” N/A 4’ - 0” N/A

N/A

1.2

(10) #7

NONE

CB3G

3’ - 6” 3’ - 6” N/A 4’ - 0” N/A

N/A

1.6

(12) #7

NONE

CB4G

4’ - 0” 4’ - 0” N/A 4’ - 0” N/A

N/A

2.1

(12) #8

NONE

CB5G

2’ - 0” 4’ - 0” 1’ - 0” 4’ - 0” 3’ - 3” 1’ - 3”

1.1

(8) #6

(Total of 10)

CB6G

2’ - 0” 4’ - 6” 1’ - 3” 4’ - 0” 3’ - 3” 1’ - 3”

1.3

(8) #6

(Total of 12)

CB7G

2’ - 0” 5’ - 0” 1’ - 6” 4’ - 6” 3’ - 9” 1’ - 3”

1.6

(8) #6

(Total of 12)

(5) #5

(6) #5 (6) #5

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS

G

GENERAL NOTES FOR G-SERIES TOWERS 1. The suitability of a ROHN standard design and standard foundation for a specific application must be verified by the purchaser based on site-specific data in accordance with ANSI/TIA-222-G. 2. The effective projected area and lines to be installed must not exceed the design values for the structure. 3. Structures supported on buildings or other strucutres require special consideration. Designs assume structures are installed on level grade. 4. Designs assume maintenance and inspection will be performed over the life of the structure in accordance with ANSI/TIA-222-G. All towers should be thoroughly inspected by qualified personnel and re-marked as required with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance. 5. Standard Designs are intended to be climbed by skilled and competent climbers only. A safety climb system is required for all structures. 6. Installation and dismantling must be performed by qualified and experienced personnel and be in conformance with ANSI/TIA-222-G. 7. Standard guyed masts and bracketed towers are not stable without guys or brackets attached and will not support personnel in this condition. Temporary steel guys supplied by a qualified contractor may be required to maintain stability during installation or dismantling. 8. Do not install or dismantle structures within falling distance of electrical and/or telephone lines without taking special precautions in accordance with the appropriate utility. 9. All field connections are bolted. 10. The tolerance on installed height is equal to plus 1% and minus 1/2%. 11. Installation must be grounded in accordance with local and national codes. ANSI/TIA-222-G requires that the resistance to ground must not exceed 10 ohms. Additional grounding may be required in addition to the ROHN standard grounding kit provided with the tower. 12. Additional anchor rod corrosion protection may be required based on site-specific conditions. 13. Installation must be in conformance with local, state and federal requirements for obstruction marking and lighting. 14. Warning plate P/N: AWCS provided with the structure must be installed in a highly visible location.

G - S E R I E S F O U N D AT I O N G E N E R A L N O T E S 1. Standard foundation designs (unless otherwise noted) are in accordance with ANSI/TIA-222-G, “Structural Standards for Steel Antenna Towers and Antenna Supporting Structures,” Section 9 and Annex F for the following presumptive clay soil parameters:

O N (blows/ft) (deg) 8

0

Y (lb/ft3)

c (psf)

110

1000

Ultimate Bearing (psf) Shallow Deep Fdns. Fdns. 5000

9000

Ultimate Skin Friction (psf)

k (pci)

50

500

150

0.01

2. The purchaser must verify that actual site soil parameters meet or exceed the assumed soil conditions and that the depth of standard foundations are adequate based on the frost penetration and/or zone of seasonal moisture variation at the site. Foundation design modifications may be required in the event the assumed soil parameters are not applicable for the actual subsurface conditions encountered.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

147


G

GUYED TOWERS

G - S E R I E S F O U N D AT I O N G E N E R A L N O T E S 3. Foundation designs assume field inspections will be performed by the purchasers’ representative to verify that construction materials, installation methods and assumed design parameters are acceptable based on the conditions existing at the site. 4. Work shall be in accordance with local codes, safety regulations and unless otherwise noted, the latest revision of ACI 318, “Building Code Requirements for Reinforced Concrete.” Procedures for the protection of excavations, existing construction and utilities shall be established prior to foundation installations. 5. Concrete materials shall conform to the appropriate state requirements for exposed structural concrete. 6. Proportions of concrete materials shall be suitable for the installation method utilized and shall result in durable concrete for resistance to local anticipated aggressive actions. The durability requirement of ACI 318 Chapter 4 shall be satisfied based on the conditions expected at the site. As a minimum, concrete shall develop a minimum compressive strength of 4000 psi in 28 days. 7. Maximum size of aggregate shall not exceed the size suitable for the installation method utilized or 1/3 the clear distance behind or between reinforcing. Maximum size may be increased to 2/3 the clear distance provided workability and methods of consolidation such as vibrating will prevent honeycombs or voids. 8. Reinforcement shall be deformed and conform to the requirements of ASTM A615 Grade 60 unless otherwise noted. Splices in reinforcement shall not be allowed unless otherwise indicated. 9. Reinforcing cages shall be braced to retain proper dimensions during handling and throughout placement of concrete. 10. Welding is prohibited on reinforcing steel and embedments. 11. Minimum concrete cover for reinforcement shall be 3 inches unless otherwise noted. Appropriate spacers shall be used to insure a 3 inch minimum cover on reinforcement. 12. Concrete cover from top of foundations to ends of vertical reinforcement shall not exceed 3 inches nor be less than 2 inches. 13. Spacers shall be attached intermittently throughout the entire length of vertical reinforcing cages to insure concentric placement. 14. Foundation designs assume structural backfill to be compacted in 8 inch maximum layers to 95% of maximum dry density at optimum moisture content in accordance with ASTM D698. Additionally, structural backfill must have a minimum compacted until weight of 100 pounds per cubic foot. 15. Foundation designs assume level grade at the site. 16. Foundation installations shall be supervised by personnel knowledgeable and experienced with the proposed foundation type. Construction shall be in accordance with generally accepted installation practices. 17. Loose material shall be removed from bottom of excavations prior to concrete placement. Sides of excavations shall be rough and free of loose cuttings. 18. Concrete shall be placed in a manner that will prevent segregation of concrete materials and other occurrences which may decrease strength or durability. 19. Free fall concrete may be used provided fall is vertical down without hitting sides of excavation, form work, reinforcing bars, form ties, cage bracing or other obstructions. Under no circumstances shall concrete fall through water. 20. Concrete shall be placed against undisturbed soil except for piers in pier and pad foundations. Forms for piers shall be removed prior to placing structural backfill. 21. Construction joints, if required in piers must be at least 12 inches below bottom of embedments and must be intentionally roughened to a full amplitude of 1/4 inch. Foundation designs assume no other construction joints. 22. Tops of foundations shall be sloped to drain with a floated finished. 23. Exposed edges of concrete shall be chamfered 3/4” x 3/4”. 24. Additional corrosion protection may be required for steel guy anchors in direct contact with soil. Design assumes periodic inspections will be performed over the life of the structure to determine if additional anchor corrosion protection measures must be implemented based on observed site-specific conditions.

148

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard ©2011 ROHN PRODUCTS LLC


GUYED TOWERS

G

F O U N D AT I O N T O L E R A N C E S GENERAL 1. Concrete dimensions - plus 2” or minus 0“. 2. Depth of foundation - plus 3” or minus 0”. 3. Drilled foundations out-of-plumb - 1.0 degree. 4. Reinforcing steel placement - per A.C.I. 301. 5. Projection of embedments - plus or minus 1/8”. 6. Vertical embedments out of plumb - 0.5 degree.

GUY ANCHORS 1. Guy radius - plus or minus 5% of distance specified. 2. Anchor elevation - plus or minus 5% of guy radius. 3. Anchor alignment (perpendicular to guy radius) - 1.0 degree. 4. Anchor rod slope - plus or minus 1.0 degree. 5. Anchor rod alignment with guy radius - plus or minus 1.0 degree. 6. Anchor head out of plumb - 1.0 degree. 7. Guy initial tension - plus or minus 10% of tension specified. Note: Tolerances in notes 1 & 2 cannot occur simultaneously.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

149


G

GUYED TOWERS

G U Y A R R A N G E M E N T D E TA I L S

Turnbuckle (TYP)

Anchor Rod (TYP)

2 Guy Attachment

1 Guy Attachment

4 Guy Attachment

Wire Size 3/16 EHS

1/4EHS

5/16EHS

3/8EHS

150

Anchor Rod

3 Guy Attachment

5 Guy Attachment

Turnbuckle

Thimble

GAC3455TOP

1/2TBE&J

5/16THH

GAC5655TOP

5/8TBE&J

5/16THH

GAC3455TOP

1/2TBE&J

3/8THH

GAC5655TOP

5/8TBE&J

3/8THH

GAC5755TOP

3/4TBE&J

3/8THH

GAC3455TOP

5/8TBE&J

7/16THH

GAC5655TOP

5/8TBE&J

7/16THH

GAC5755TOP

3/4TBE&J

7/16THH

GAC3455TOP

5/8TBE&J

1/2THH

GAC5655TOP

5/8TBE&J

1/2THH

GAC5755TOP

3/4TBE&J

1/2THH

Big Grip w/ End Sleeve BG2142

BG2144

BG2146

BG2174

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard ©2011 ROHN PRODUCTS LLC


GUYED TOWERS

G

G U Y A N C H O R C O N N E C T I O N D E TA I L S

End Sleeve

Big Grip Preform (TYP) Turnbuckle (TYP)

Thimble (TYP)

Equalizer Plate Turnbuckle Safety Cables 1/4” EHS Wire (up to 1” turnbuckles) 5/16” EHS Wire (1 1/4” turnbuckles & larger)

Anchor Rod

Cable Clamps

Anchor Connection

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

151


G

GUYED TOWERS

G U Y M A S T C O N N E C T I O N D E TA I L S

Tower Brace (REF)

Tower Brace (REF) Tower Leg (REF)

Tower Leg (REF) Guy Lug

Guy Link

Shackle Thimble

Thimble Guy bracket must rest on horizontal tower brace and lugs when provided for larger guys. Big Grip Preform

Guy Tension Bar Big Grip Preform

Guy Bracket Connection 25G, 45G, 45GSR, 55G

Guy Lug Connection 45GSR

Tower Brace (REF) Tower Leg (REF) Bolt-On Guy Bracket

Thimble

Big Grip Preform

Bolt-On Guy Bracket Connection 65G

152

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard ©2011 ROHN PRODUCTS LLC


GUYED TOWERS

G

PA L N U T I N S TA L L AT I O N

Pal Nut Bolt Nut Flange Plates

Tower Leg

When pal nuts are provided, they are to be installed after nuts are tight and with edge lip out as shown. Pal nuts are not required when self-locking nuts or lock washers are provided.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

153


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.