ROHN 55G Tower

Page 1


G

GUYED TOWERS - 55G

S TA N D A R D 5 5 G G U Y E D T O W E R

ROHN 55G The first. The original.

includes

REV. F & REV. G

55G

GENERAL USE The 55G lends itself to a wide variety of uses, particularly where unusual wind loading and height requirements exist. The 55G was designed to provide excellent strength in heights up to 400’.

FEATURES • Completely hot-dip galvanized after fabrication • Built on a 17” equilateral triangle design • High strength tubular legs joined by Zig-Zag®

cross members

• Each section contains all required nuts and bolts

shipped with section

• Continuous solid round steel bracing

CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.

Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 116 for ordering information.

100

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D 5 5 G G U Y E D T O W E R SECTIONS 9 13/16” 14 3/4”

QUICK REFERENCE PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION

17”

PAGES 115-116 PAGE 117 PAGES 117-120

Optional Waveguide Brackets (KY2041A)

TOP PLATE APL55G

1 1/2” O.D. (11 GA.)

FOR MOUNTING BEACON OR LIGHTNING ROD. TOP PLATE BOLTS TO THE TOP OF A STANDARD SECTION.

7/16” O.D. Solid Bracing

Optional double braced sections are available upon request.

CONCRETE BASE PLATE BPC55G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. Additional base sections are available, please see page 115.

STANDARD SECTION 55G - 10’ Section * Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

101


G

GUYED TOWERS - 55G

BUYERS GUIDE S TA N D A R D D E S I G N S - 5 5 G 9 0 M P H R E V. G [ 3 S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]

Design Criteria

EPA (SQ. FT.) For Exposure B, Revision G 30.4

39.0

85’

EPA (SQ. FT.) For Exposure C, Revision G

32.0 117’

42’

90’

1/4” EHS (665#) 3/16” EHS (399#)

EPA (SQ. FT.), Revision F Guy Initial Tension

P/N 55G90R100 80’

P/N 55G90R100

Tower Model Windspeed (Rev. G)

Tower Height (ft.) ROHN Tower

EPA= Effective Projected Area

This document is to serve as a guide for sizing and purchasing the 55G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 117-120. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.

102

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 100’ TOWER 39.0 OR 30.4

85’

32.0 117’ 1/4” EHS (665#)

42’

90’

3/16” EHS (399#)

80’

P/N: 55G90R100

95’

110’ TOWER 37.9 OR 29.8 31.2 129’ 1/4” EHS (665#)

47’

100’

3/16” EHS (399#)

88’

P/N: 55G90R110

105’

120’ TOWER 37.0 OR 29.3 30.4 142’ 3/16” EHS (399#)

75’ 122’ 35’

1/4” EHS (665#)

102’ 96’

P/N: 55G90R120

115’

130’ TOWER 36.1 OR 28.7 29.8 155’ 3/16” EHS (399#)

76’ 129’ 38’

1/4” EHS (665#)

111’ 104’

P/N: 55G90R130

125’

140’ TOWER 35.4 OR 28.3 29.0 168’ 3/16” EHS (399#)

83’ 139’ 41’

1/4” EHS (665#)

119’ 112’

P/N: 55G90R140

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

10

1

1

GA55GD BASEFDNS ANCHOR 2

100’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 100

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 300’

6

375’

6

6

6

6

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

11

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 2

110’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 110

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 325’

6

425’

6

6

6

6

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

12

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 3

120’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 120

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’

12

475’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

13

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 3

130’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 130

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 775’

12

500’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

14

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 3

140’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 140

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 825’

12

550’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

103


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 150’ TOWER 34.7 OR 27.9 28.6

135’

181’ 3/16” EHS (399#)

92’ 151’ 45’

1/4” EHS (665#)

128’ 120’

P/N: 55G90R150 160’ TOWER 33.9 OR 27.5 28.0

145’

193’ 3/16” EHS (399#)

96’ 160’ 48’

1/4” EHS (665#)

137’ 128’

P/N: 55G90R160

170’ TOWER 33.3 OR 27.2 27.4

155’

206’

115’

178’ 75’

155’

1/4” EHS (665#) 3/16” EHS (399#)

141’

37’

136’

P/N: 55G90R170 180’ TOWER 32.8 OR 26.8 27.0

165’

219’

124’

190’ 83’

166’

1/4” EHS (665#) 3/16” EHS (399#)

150’

42’

144’

P/N: 55G90R180 190’ TOWER 32.4 OR 26.5 26.6

175’

232’

131’

201’ 87’

175’

5/16” EHS (1,120#) 3/16” EHS (399#)

158’

43’

152’

P/N: 55G90R190

104

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

15

1

1

GA55GD BASEFDNS ANCHOR 3

150’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 150

CB2G AB2

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 900’

12

600’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

16

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 3

160’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 160

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 950’

12

625’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

17

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 4

170’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 170

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1525’

18

675’

6

18

6

12

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

18

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 4

180’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 180

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1625’

18

700’

6

18

6

12

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

19

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 4

190’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 190

3/16EHS142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1700’

18

750’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 185’ 139’

200’ TOWER 31.9 OR 26.2 24.2 245’ 212’

93’ 47’

185’

5/16” EHS (1,120#) 3/16” EHS (399#)

167’ 160’

P/N: 55G90R200

205’ 164’ 123’ 82’ 41’

220’ TOWER 31.1 OR 25.7 23.4 270’ 3/16” EHS 241’ (399#) 215’

5/16”EHS (1,120#)

194’ 181’

176’

P/N: 55G90R220

225’ 182’ 135’ 92’ 45’

240’ TOWER 30.3 OR 25.3 22.8 296’ 3/16” EHS 265’ (399#) 5/16” EHS (1,120#) 235’ 213’ 197’ 192’

P/N: 55G90R240

245’ 202’ 162’ 122’ 82’ 42’

260’ TOWER 29.6 OR 24.8 22.2 321’ 290’ 5/16” EHS (1,120#) 264’ 3/16” EHS (399#) 241’ 104’ 77’ 64’

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

208’

P/N: 55G90R260

ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

20

1

1

GA55GD BASEFDNS ANCHOR 4

CB2G AB3

200’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 200

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1800’

18

800’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

22

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 5

CB2G AB3

220’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 220

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 3/4TBE&J 2650’

24

875’

6

24

6

15

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

24

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 5

CB3G AB3

240’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 240

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 3/4TBE&J 2900’

24

950’

6

24

6

15

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

26

1

1

6

3/16EHS

142265

BG2142

BG2146

5/16THH

3125’

1025’

30

6

30

7/16THH

1/2TBE&J

5/8TBE&J

6

6

12

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB3G AB2

AB3

260’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 260

CPC.5/.75 CPC1/1.25 3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 3

3

2

3

6

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

105


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 280’ TOWER 29.0 OR 24.4

265’

21.8

222’

347’ 315’ 5/16” EHS (1,120#) 284’ 3/16” EHS (399#) 260’

175’ 132’ 85’

110’ 82’

43’

70’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

224’

P/N: 55G90R280

ANCHORS & GROUNDING INCLUDED 300’ TOWER 28.4 OR 24.1

285’

21.2

242’

373’ 341’ 5/16” EHS (1,120#) 314’ 3/16” EHS (399#) 290’

202’ 162’ 122’ 82’ 42’

158’ 129’ 108’ 100’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

240’

P/N: 55G90R300

ANCHORS & GROUNDING INCLUDED 320’ TOWER 27.9 OR 23.8

305’

20.8

262’

398’ 366’ 5/16” EHS (1,120#) 334’ 3/16” EHS (399#) 308’ 1/4”EHS (665#) 160’ 129’ 108’

215’ 172’ 125’ 82’ 42’

100’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

256’

P/N: 55G90R320

ANCHORS & GROUNDING INCLUDED 340’ TOWER 27.4 OR 23.5

325’

20.4

282’ 242’ 202’ 162’

424’ 392’ 364’ 339’ 317’

122’ 82’ 42’

155’ 126’ 105’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

96’

GUYS & CONNECTIONS INCLUDED

272’

P/N: 55G90R340

ANCHORS & GROUNDING INCLUDED

106

INNER OUTER BASE ANCHOR ANCHOR

55G

BPC55G

APL55G

GA55GD

28

1

1

6

CB4G AB2

3/16EHS

142265

BG2142

BG2146

5/16THH

3350

1125’

30

6

30

7/16THH

1/2TBE&J

5/8TBE&J

6

6

12

AB3

280’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 280

CPC.5/.75 CPC1/1.25 3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 6

3

3

2

3

55G

BPC55G

APL55G

GA55GD

30

1

1

7

CB4G AB2

3/16EHS

142265

BG2142

BG2146

5/16THH

4275’

1200’

36

6

36

7/16THH

1/2TBE&J

6

9

1

INNER OUTER BASE ANCHOR ANCHOR

AB3

300’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 300

5/8TBE&J CPC.5/.75 CPC1/1.25 12

3

3

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 3

3

2

3

55G

BPC55G

APL55G

GA55GD

32

1

1

7

3/16EHS

1/4EHS

142265

BG2142

2250’

2250’

1275’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

12

6

9

6

1

INNER OUTER BASE ANCHOR ANCHOR

CB4G AB2 BG2144

AB3 BG2146

320’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 320

12

6

12

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

2

3

55G

BPC55G

APL55G

GA55GD

34

1

1

8

CB4G AB2

3/16EHS

1/4EHS

142265

BG2142

BG2144

3325’

2425’

1350’

30

5/16THH

3/8THH

7/16THH

1/2TBE&J

30

12

6

9

3

1

INNER OUTER BASE ANCHOR ANCHOR

AB3 BG2146

340’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 340

12

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 360’ TOWER 27.0 OR 23.2

345’

20.0

302’ 255’ 212’ 168’

449’ 417’ 385’ 358’ 333’

126’ 84’ 42’

161’ 131’ 108’

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

100’ 288’

P/N: 55G90R360

ANCHORS & GROUNDING INCLUDED

365’ 319’ 273’ 227’ 181’ 135’ 92’ 45’

380’ TOWER 26.6 OR 22.9 475’ 441’ 409’ 379’ 354’ 174’ 143’ 119’

19.6

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

110’ 304’

P/N: 55G90R380

ANCHORS & GROUNDING INCLUDED

385’ 335’ 285’ 235’ 185’ 138’ 92’ 46’

400’ TOWER 26.1 OR 22.7 19.2 501’ 463’ 5/16” EHS 429’ (1,120#) 397’ 3/16” EHS (399#) 370’ 1/4”EHS (665#) 183’ 151’ 129’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

120’ 320’

P/N: 55G90R400

ANCHORS & GROUNDING INCLUDED

INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR

55G

BPC55G

APL55G

36

1

1

8

2

3/16EHS

1/4EHS

142265

BG2142

BG2144

3475’

2575’

1450’

30

5/16THH

3/8THH

7/16THH

1/2TBE&J

30

12

6

9

BG2146

AB4

360’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 360

12

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 3

CB5G AB2

CPC1/1.25 3

3

3

3

2

55G

BPC55G

APL55G

38

1

1

8

2

CB5G AB2

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

3175’

3275’

1525’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

18

6

9

INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR

AB4

380’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 380

18

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

3

3

2

55G

BPC55G

APL55G

40

1

1

8

2

CB5G AB2

3/16EHS

1/4EHS

142265

BG2142

BG2144

BG2146

2075’

4700’

1600’

18

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

5/8TBE&J

18

24

6

9

15

INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 3

3

2

3

AB4

400’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng TBSAFETY Par t No: 55G90R 400

6

6

CPC1/1.25 3/4x12PP

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

3

1

107


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 95’

100’ TOWER 26.1 OR 20.4 19.2 124’ 3/16” EHS (399#)

63’ 102’ 33’

1/4” EHS (665#)

87’ 80’

P/N: 55G110R100

105’

110’ TOWER 25.4 OR 19.9 18.6 137’ 3/16” EHS (399#)

72’ 114’ 35’

1/4” EHS (665#)

95’ 88’

P/N: 55G110R110

115’

120’ TOWER 24.8 OR 19.6 18.2 150’ 3/16” EHS (399#)

77’ 123’ 38’

1/4” EHS (665#)

103’ 96’

P/N: 55G110R120

125’

130’ TOWER 24.2 OR 19.2 17.8 163’ 3/16” EHS (399#)

83’ 133’ 42’

1/4” EHS (665#)

112’ 104’

P/N: 55G110R130

135’ 101’

140’ TOWER 23.6 OR 18.9 17.2 175’ 151’

67’ 34’

131’

1/4” EHS (665#) 3/16” EHS (399#)

117’ 112’

P/N: 55G110R140

108

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

10

1

1

GA55GD BASEFDNS ANCHOR 3

100’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 100

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 600’

12

400’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

11

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 3

110’ ROHN 55G

CB1G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 110

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 675’

12

450’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

12

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 3

120’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 120

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’

12

500’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

13

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 3

130’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 130

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 800’

12

525’

6

12

6

9

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

14

1

1

3

3

1

GA55GD BASEFDNS ANCHOR 4

140’ ROHN 55G

CB2G AB2

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 140

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1275’

18

575’

6

18

6

12

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

1

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 150’ TOWER 23.2 OR 18.7

145’

16.8 188’

108’

161’ 72’

140’

1/4” EHS (665#) 3/16” EHS (399#)

125’

36’

120’

P/N: 55G110R150 160’ TOWER 22.8 OR 18.4

155’

16.4 201’

116’

173’ 78’

150’

5/16” EHS (1,120#) 3/16” EHS (399#)

134’

39’

128’

P/N: 55G110R160 170’ TOWER 22.4 OR 18.2 16.2

165’

214’

124’

184’ 83’

159’

1/4” EHS (665#) 3/16” EHS (399#)

142’

41’

136’

P/N: 55G110R170 180’ TOWER 22.0 OR 18.0 15.8

175’

227’

142’

202’

105’

178’

72’

3/16” EHS (399#) 1/4” EHS (665#)

161’

35’

148’ 144’

P/N: 55G110R180

185’ 148’ 111’ 74’ 37’

190’ TOWER 21.7 OR 17.8 15.6 239’ 212’ 188’ 169’ 156’

3/16” EHS (399#) 5/16” EHS (1,120#) 1/4”EHS (665#)

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

152’

P/N: 55G110R190

ANCHORS & GROUNDING INCLUDED

55G

BPC55G

APL55G

15

1

1

GA55GD BASEFDNS ANCHOR 4

150’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 150

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 1375’

18

600’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

16

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 4

160’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 160

3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1475’

18

650’

6

18

6

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

17

1

1

3

1

3

GA55GD BASEFDNS ANCHOR 4

170’ ROHN 55G

CB2G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 170

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 975’

12

1275’

12

12

12

12

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

18

1

1

1

3

3

GA55GD BASEFDNS ANCHOR 5

180’ ROHN 55G

CB3G AB3

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 180

3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 1550’

18

1375’

12

18

12

15

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

GA55GD

19

1

1

5

3/16EHS

1/4EHS

142265

BG2142

BG2144

1650’

675’

775’

18

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

18

6

6

15

3

1

FDNS

BASE ANCHOR

CB3G AB3

190’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 190

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

109


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 195’ 156’ 117’ 78’ 39’

200’ TOWER 21.4 OR 17.6 13.2 252’ 3/16” EHS 223’ (399#) 5/16” EHS (1,120#) 198’ 1/4”EHS (665#)

178’ 165’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

160’

P/N: 55G110R200

ANCHORS & GROUNDING INCLUDED 220’ TOWER 20.8 OR 17.2 12.8

215’ 182’

278’ 253’ 5/16” EHS (1,120#) 228’ 3/16” EHS (399#) 209’ 1/4”EHS (665#) 94’ 70’

145’ 112’ 73’ 36’

60’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

176’

P/N: 55G110R220

ANCHORS & GROUNDING INCLUDED

235’ 201’ 167’ 133’ 99’ 66’ 33’

240’ TOWER 20.3 OR 16.9 12.4 303’ 278’ 5/16” EHS (1,120#) 254’ 3/16” EHS (399#) 234’ 1/4”EHS (665#) 127’ 104’ 87’ 80’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

192’

P/N: 55G110R240

ANCHORS & GROUNDING INCLUDED

255’ 219’ 183’ 147’ 111’ 75’ 38’

260’ TOWER 19.8 OR 16.6 12.0 329’ 302’ 5/16” EHS (1,120#) 277’ 3/16” EHS (399#) 255’ 1/4”EHS (665#) 142’ 116’ 96’ 88’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

208’

P/N: 55G110R260

ANCHORS & GROUNDING INCLUDED

110

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

20

1

1

5

3/16EHS

1/4EHS

142265

BG2142

BG2144

1750’

725’

825’

18

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

18

6

6

15

CB3G AB3

200’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 200

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

22

1

1

6

3/16EHS

1/4EHS

142265

BG2142

1925’

825’

900’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

6

6

6

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB4G AB2 BG2144

AB3 BG2146

220’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 220

6

6

12

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

55G

BPC55G

APL55G

24

1

1

7

3/16EHS

1/4EHS

142265

BG2142

1775’

1700’

975’

24

5/16THH

3/8THH

7/16THH

1/2TBE&J

24

12

6

9

3

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB4G AB2 BG2144

AB3 BG2146

240’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 240

12

6

12

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

2

55G

BPC55G

APL55G

26

1

1

7

3/16EHS

1/4EHS

142265

BG2142

BG2144

1500’

2300’

1050’

18

18

5/16THH

3/8THH

7/16THH

18

18

6

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB5G AB2

1/2TBE&J 5/8TBE&J 9

12

AB3 BG2146

260’ ROHN 55G

Al l par ts shown i n tabl e are i nc l uded when order i ng TBSAFETY Par t No: 55G110R 260

6

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

3

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 275’ 241’ 207’ 173’ 139’ 105’ 71’ 35’

280’ TOWER 19.4 OR 16.4 355’ 329’ 305’ 283’ 264’ 134’ 110’ 91’

11.6

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

84’

GUYS & CONNECTIONS INCLUDED

224’

P/N: 55G110R280

ANCHORS & GROUNDING INCLUDED

295’ 259’ 223’ 187’ 151’ 115’ 79’ 41’

300’ TOWER 19.0 OR 16.1 380’ 353’ 328’ 304’ 284’ 152’ 127’ 108’

11.2

TOWER PARTS INCLUDED

5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)

GUYS & CONNECTIONS INCLUDED

100’ 240’

P/N: 55G110R300

ANCHORS & GROUNDING INCLUDED

INNER OUTER GA55GD BASE ANCHOR ANCHOR

55G

BPC55G

APL55G

28

1

1

8

3/16EHS

1/4EHS

142265

BG2142

2825’

2025’

1150’

30

5/16THH

3/8THH

7/16THH

1/2TBE&J

30

12

6

9

CB5G AB2 BG2144

AB4 BG2146

280’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 280

12

6

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

3

2

55G

BPC55G

APL55G

30

1

1

8

3/16EHS

1/4EHS

142265

BG2142

1675’

2500’

2350’

18

5/16THH

3/8THH

7/16THH

1/2TBE&J

18

18

12

9

3

3

1

INNER OUTER GA55GD BASE ANCHOR ANCHOR

CB5G AB2 BG2144

AB4 BG2146

300’ ROHN 55G

Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 300

18

12

15

6

GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3

3

2

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

3

1

111


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 100’ TOWER 18.7 OR 14.6

95’

124’

18.0

5/16” EHS (1120#) 3/16” EHS (399#) 102’ 1/4” EHS (665#)

63’

33’

87’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

80’

P/N: 55G130R100

ANCHORS & GROUNDING INCLUDED 110’ TOWER 18.2 OR 14.2 16.0 137’ 5/16” EHS (1120#) 3/16” EHS (399#) 114’ 1/4” EHS (665#)

105’

72’

35’

95’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

88’

P/N: 55G130R110

ANCHORS & GROUNDING INCLUDED 120’ TOWER 17.7 OR 14.0 14.0 150’ 5/16” EHS (1120#) 3/16” EHS (399#) 123’ 1/4” EHS (665#)

115’

77’

38’

103’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

96’

P/N: 55G130R120

ANCHORS & GROUNDING INCLUDED 130’ TOWER 17.3 OR 13.8 12.0 163’ 5/16” EHS (1120#) 1/4” EHS (665#) 133’

125’

83’

42’

112’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

104’

P/N: 55G130R130

ANCHORS & GROUNDING INCLUDED

112

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

10

1

1

3

3/16EHS

1/4EHS

142265

BG2142

300’

325’

400’

6

BG2146

5/16THH

3/8THH

7/16THH

6

6

6

6

CB2G AB2 BG2144

100’ ROHN 55 G

All par ts shown in table are i nclu de d when order ing 1/2TBE&J 5/8TBE&J Par t No: 55G130R100

6

6

3

GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

11

1

1

3

3/16EHS

1/4EHS

142265

BG2142

BG2144

325’

375’

450’

6

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

6

6

9

3

1

FDNS GA55GD BASE ANCHOR CB2G AB3

110’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R110

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

12

1

1

3

3/16EHS

1/4EHS

142265

BG2142

BG2144

350’

400’

500’

6

6

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

6

6

9

3

1

FDNS GA55GD BASE ANCHOR CB2G AB3

120’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R120

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

1

3

55G

BPC55G

APL55G

13

1

1

1/4EHS

142265

BG2144

BG2146

800’

525’

12

6

3/8THH

7/16THH

12

6

3

3

FDNS GA55GD BASE ANCHOR 3

CB2G AB3

130’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R130

5/8TBE&J TBSAFETY 9

1

3

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 3/4x12PP 3

1

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 135’ 101’ 67’ 34’

140’ TOWER 16.9 OR 13.6 11.0 175’ 5/16” EHS (1120#) 151’ 1/4” EHS (665#) 131’ 3/16” EHS (399#) 117’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

112’

P/N: 55G130R140

ANCHORS & GROUNDING INCLUDED

145’ 108’

150’ TOWER 16.6 OR 13.4 10.0 188’ 161’

72’ 36’

140’

TOWER PARTS INCLUDED

5/16” EHS (1120#) 1/4” EHS (665#) 3/16” EHS (399#)

125’

GUYS & CONNECTIONS INCLUDED

120’

P/N: 55G130R150

ANCHORS & GROUNDING INCLUDED

155’ 116’ 78’ 39’

160’ TOWER 16.3 OR 13.2 9.8 201’ 5/16” EHS (1120#) 173’ 1/4” EHS (665#) 150’ 3/16” EHS (399#) 134’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

128’

P/N: 55G130R160

ANCHORS & GROUNDING INCLUDED

165’ 124’ 83’ 41’

170’ TOWER 16.0 OR 13.0 9.6 214’ 5/16” EHS (1120#) 184’ 1/4” EHS (665#) 159’ 3/16” EHS (399#) 142’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

136’

P/N: 55G130R170

ANCHORS & GROUNDING INCLUDED

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

14

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

375’

900’

575’

6

12

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

12

6

3

CB3G AB3

140’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 140

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

15

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

400’

975’

600’

6

12

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

12

6

3

3

1

FDNS GA55GD BASE ANCHOR CB3G AB3

150’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 150

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

16

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

450’

1050’

650’

6

12

BG2146

5/16THH

3/8THH

7/16THH

5/8TBE&J

6

6

12

6

12

3

1

FDNS GA55GD BASE ANCHOR CB3G AB3

160’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 160

GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3

3

1

3

55G

BPC55G

APL55G

17

1

1

4

3/16EHS

1/4EHS

142265

BG2142

BG2144

475’

1100’

700’

6

12

BG2146

5/16THH

3/8THH

7/16THH

3/4TBE&J

6

6

12

6

12

3

1

FDNS GA55GD BASE ANCHOR CB3G AB4

170’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 170

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3

1

3

3

3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

1

113


G

GUYED TOWERS - 55G

S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 180’ TOWER 15.8 OR 12.9

175’

9.2 227’

142’

5/16” EHS (1120#) 202’ 1/4” EHS (665#) 178’ 3/16”EHS 161’ (399#)

105’ 72’ 35’

148’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

144’

P/N: 55G130R180

ANCHORS & GROUNDING INCLUDED 190’ TOWER 15.5 OR 12.7 9.0

185’

239’

152’

5/16” EHS (1120#) 215’ 1/4” EHS (665#) 191’

115’ 82’

173’

41’

157’

TOWER PARTS INCLUDED

GUYS & CONNECTIONS INCLUDED

152’

P/N: 55G130R190

ANCHORS & GROUNDING INCLUDED

114

FDNS GA55GD BASE ANCHOR

55G

BPC55G

APL55G

18

1

1

5

3/16EHS

1/4EHS

142265

BG2142

BG2144

1000’

1225’

725’

12

12

BG2146

5/16THH

3/8THH

7/16THH

3/4TBE&J

6

12

12

6

15

CB3G AB4

180’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 180

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 1

3

1

3

3

3

55G

BPC55G

APL55G

GA55GD

BASE ANCHOR

19

1

1

5

1/4EHS

142265

BG2144

BG2146

190’ ROHN 55G

2350’

775’

24

6

3/8THH

7/16THH

Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 190

24

6

FDNS

CB4G AB4

3/4TBE&J TBSAFETY 15

3

GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 3/4x12PP 3

1

3

3

1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 55G

PA R T S & A CC E S S O R I E S

TOP PLATE APL55G FOR MOUNTING BEACON OR LIGHTNING ROD.

BEARING PLATE BPL55G

ACCESSORY SHELF AS455G

CONVERTS STANDARD SECTION TO A TOP SECTION. HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARING.

FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.

TOP MOUNT 55TDMKD - NO MAST 55TDM2S3KD - 2 3/8” O.D. MAST 55TDM25S3KD - 2 7/8” O.D. MAST 55TDM3S3KD - 3 1/2” O.D. MAST 55TDM35S3KD - 4” O.D. MAST 55TDM4S3KD - 4 1/2” O.D. MAST MOUNTING TUBE PROVIDED IS 7’.

TAPERED BASE* 55TG - STANDARD 55TGIA - USE WITH A4197L BASE INSULATOR

CONCRETE BASE PLATE BPC55G* LIGHTNING ROD LRCL

5’ COPPER CLAD, MOUNTS TO APL55G.

FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. CONCRETE BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.

PIER PIN 3/4X12PP

55TGIAA - USE WITH

A4722B BASE INSULATOR

FOR USE WITH BPC55G EMBEDDED IN CONCRETE.

INSULATOR AND PIER PIN MUST BE ORDERED SEPARATELY.

PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.

Adjustable 2.5’ - 3.0’

5’ SHORT BASE SB55G

FLAT ROOF MOUNT FR55G* BOLTS DIRECTLY TO FLAT ROOF SURFACE.

FOR EMBEDMENT IN CONCRETE.

SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.

FACE MOUNT DM55G2 - 2 3/8” O.D. 5’ LONG DM554 - 4 1/2” O.D. 5’ LONG

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

115


G

GUYED TOWERS - 55G

PA R T S & A CC E S S O R I E S

HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 18” - 36” FROM WALL.

TORQUE ARM STABILIZER ASSEMBLY TA55 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER.

THRUST BEARING TB3 - SUPPORTS UP TO 2” O.D. MAST. TB4 - SUPPORTS UP TO 3” O.D. MAST. MOUNTS TO BPL55G.

ANTI-CLIMB PANELS 455ACL3

TORQUE BAR TB55D

OPTIONAL, FOR USE WITH GA55GD. REQUIRES (1) 3/8” SHACKLE FOR EACH BAR.

WORK PLATFORM WP55G SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

GUY BRACKET GA55GD MOUNTS TO TOWER AT ANY HORIZONTAL BRACE.

SAFETY RING SR55 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.

THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.

SAFETY CABLE SYSTEM ORDERING INFORMATION

CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS

TTFBH-C/P

PROFESSIONAL HARNESS

116

SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC

TOWER HEIGHT 50’ 100’ 150’ 200’ 250’ 300’ 350’ 400’

PART NUMBER TT0504555 TT1004555 TT1504555 TT2004555 TT2504555 TT3004555 TT3504555 TT4004555

SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


G

GUYED TOWERS - 55G

A N C H O R I N F O R M AT I O N 81”

12”

3/8” CL of hole to edge of plate = 1”

P/N STAMPED HERE

3/4”

4” x 4” x 3/8” angle

2”

GAC3455TOP

11/16”

120”

12”

1/2” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 1/4”

5” x 5” x 3/8” angle

2 1/2” 13/16”

GAC5655TOP 168”

12”

3/4” CL of hole to edge of plate = 1 1/4”

P/N STAMPED HERE

1 7/16”

5” x 5” x 3/8” angle

3” 15/16”

GAC5755TOP REV G BASE GROUNDING BGK2GGX

REV G ANCHOR GROUNDING AGK1GGX

Attach to leg with supplied leg clamp Ground Wire Clamp

Ground Wire

Ground Rod Clamp 6” Min. Ground Rod

Ground Rod Clamp

6” Min.

Ground Rod, 3 provided (to be installed at 120o separation at 20’ spacing.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

117


G

GUYED TOWERS - 55G

S TA N D A R D A N C H O R B LO C K S

Anchor rod

Ground Line

All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required

o

Top and bottom horizontal bars equally spaced

A B

C

D

Refer to page 119 for anchor rod installation angles.

118

Block

Anchor Dimensions (in.) B A D C

AB2

4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”

AB3

6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”

AB4

6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”

AB5

8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”

AB6

8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”

Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side

Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC


GUYED TOWERS - 55G

G

A N C H O R R O D I N S TA L L AT I O N A N G L E S

120

Rod Angle (in degrees)

o

Tower Plan

Anchor Rod Angle

55G | 90MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’ 360’ 380’ 400’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 38 GAC5655TOP 40 GAC5655TOP 40 GAC5755TOP 38 GAC5755TOP 37 GAC3455TOP 43 GAC5655TOP 42 GAC3455TOP 42 GAC5655TOP 42 GAC3455TOP 39 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 38 GAC5655TOP 42

Ground Line

55G | 110MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’

Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 41 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 38 GAC5655TOP 38 GAC5655TOP 39 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC3455TOP 42 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 44 GAC3455TOP 41 GAC5655TOP 44 GAC3455TOP 40 GAC5655TOP 43 GAC3455TOP 39 GAC5655TOP 43

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC

55G | 130MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’

Rod Rod Number Angle GAC3455TOP 41 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5755TOP 38 GAC5755TOP 38 GAC5755TOP 37

119


G

GUYED TOWERS - 55G

S TA N D A R D B A S E P I E R S Pier Pin 4” Projection 6”

Grade

(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps E

No. 4 Circular ties, 3” Max. O.C. with 24” laps Vertical re-bars equally spaced with 90 hooks at bottom (for CB5G)

D

Roughen construction joint to a full amplitude of 1/4”

C

Foundation Pad

F

Horizontal reinforcing steel bars equally spaced each way

ELEVATION VIEW B

A

B

Alternate Square Pier

No. 4 Circular ties, 3” O.C. with 24” laps CL

A

Vertical bars equally spaced

CL

PLAN VIEW

Base

120

A

B

C

D

E

F

Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier

Horiz. Bars in Pad (No. & Size)

CB1G* 2’ - 6” 2’ - 6” N/A 4’ - 0” N/A

N/A

1.0

(8) #7

NONE

CB2G

3’ - 0” 3’ - 0” N/A 4’ - 0” N/A

N/A

1.2

(10) #7

NONE

CB3G

3’ - 6” 3’ - 6” N/A 4’ - 0” N/A

N/A

1.6

(12) #7

NONE

CB4G

4’ - 0” 4’ - 0” N/A 4’ - 0” N/A

N/A

2.1

(12) #8

NONE

CB5G

2’ - 0” 4’ - 0” 1’ - 0” 4’ - 0” 3’ - 3” 1’ - 3”

1.1

(8) #6

(5) #5

(Total of 10)

* Square pier option must be used for CB1G. Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC