G
GUYED TOWERS - 55G
S TA N D A R D 5 5 G G U Y E D T O W E R
ROHN 55G The first. The original.
includes
REV. F & REV. G
55G
GENERAL USE The 55G lends itself to a wide variety of uses, particularly where unusual wind loading and height requirements exist. The 55G was designed to provide excellent strength in heights up to 400’.
FEATURES • Completely hot-dip galvanized after fabrication • Built on a 17” equilateral triangle design • High strength tubular legs joined by Zig-Zag®
cross members
• Each section contains all required nuts and bolts
shipped with section
• Continuous solid round steel bracing
CAUTION Mixing copies of ROHN towers with ROHN towers is dangerous and voids all engineering and warranty data supplied by ROHN. Materials used by others are not the same quality and have not been tested or engineered by ROHN. Mixing ROHN tower sections with non-ROHN products may cause tower failure or injury.
Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please see page 116 for ordering information.
100
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D 5 5 G G U Y E D T O W E R SECTIONS 9 13/16” 14 3/4”
QUICK REFERENCE PARTS & ACCESSORIES GROUNDING INFORMATION FOUNDATION INFORMATION
17”
PAGES 115-116 PAGE 117 PAGES 117-120
Optional Waveguide Brackets (KY2041A)
TOP PLATE APL55G
1 1/2” O.D. (11 GA.)
FOR MOUNTING BEACON OR LIGHTNING ROD. TOP PLATE BOLTS TO THE TOP OF A STANDARD SECTION.
7/16” O.D. Solid Bracing
Optional double braced sections are available upon request.
CONCRETE BASE PLATE BPC55G* FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. Additional base sections are available, please see page 115.
STANDARD SECTION 55G - 10’ Section * Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
101
G
GUYED TOWERS - 55G
BUYERS GUIDE S TA N D A R D D E S I G N S - 5 5 G 9 0 M P H R E V. G [ 3 S E C O N D G U S T ] 7 0 M P H R E V. F [ FA S T E S T M I L E ]
Design Criteria
EPA (SQ. FT.) For Exposure B, Revision G 30.4
39.0
85’
EPA (SQ. FT.) For Exposure C, Revision G
32.0 117’
42’
90’
1/4” EHS (665#) 3/16” EHS (399#)
EPA (SQ. FT.), Revision F Guy Initial Tension
P/N 55G90R100 80’
P/N 55G90R100
Tower Model Windspeed (Rev. G)
Tower Height (ft.) ROHN Tower
EPA= Effective Projected Area
This document is to serve as a guide for sizing and purchasing the 55G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower. DESIGN NOTES: 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 1/2” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit. 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES: 1. Items listed are required for complete guyed towers. 2. Base and anchor foundations listed refer to standard foundation designations. 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length. 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material. 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower. 6. Parts lists are subject to change based on availability or revised design criteria. FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 117-120. FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
102
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 100’ TOWER 39.0 OR 30.4
85’
32.0 117’ 1/4” EHS (665#)
42’
90’
3/16” EHS (399#)
80’
P/N: 55G90R100
95’
110’ TOWER 37.9 OR 29.8 31.2 129’ 1/4” EHS (665#)
47’
100’
3/16” EHS (399#)
88’
P/N: 55G90R110
105’
120’ TOWER 37.0 OR 29.3 30.4 142’ 3/16” EHS (399#)
75’ 122’ 35’
1/4” EHS (665#)
102’ 96’
P/N: 55G90R120
115’
130’ TOWER 36.1 OR 28.7 29.8 155’ 3/16” EHS (399#)
76’ 129’ 38’
1/4” EHS (665#)
111’ 104’
P/N: 55G90R130
125’
140’ TOWER 35.4 OR 28.3 29.0 168’ 3/16” EHS (399#)
83’ 139’ 41’
1/4” EHS (665#)
119’ 112’
P/N: 55G90R140
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
55G
BPC55G
APL55G
10
1
1
GA55GD BASEFDNS ANCHOR 2
100’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 100
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 300’
6
375’
6
6
6
6
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
11
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 2
110’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 110
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 325’
6
425’
6
6
6
6
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
12
1
1
1
3
3
GA55GD BASEFDNS ANCHOR 3
120’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 120
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’
12
475’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
13
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 3
130’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 130
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 775’
12
500’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
14
1
1
1
3
3
GA55GD BASEFDNS ANCHOR 3
140’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G90R 140
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 825’
12
550’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
3
3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
1
103
G
GUYED TOWERS - 55G
S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 150’ TOWER 34.7 OR 27.9 28.6
135’
181’ 3/16” EHS (399#)
92’ 151’ 45’
1/4” EHS (665#)
128’ 120’
P/N: 55G90R150 160’ TOWER 33.9 OR 27.5 28.0
145’
193’ 3/16” EHS (399#)
96’ 160’ 48’
1/4” EHS (665#)
137’ 128’
P/N: 55G90R160
170’ TOWER 33.3 OR 27.2 27.4
155’
206’
115’
178’ 75’
155’
1/4” EHS (665#) 3/16” EHS (399#)
141’
37’
136’
P/N: 55G90R170 180’ TOWER 32.8 OR 26.8 27.0
165’
219’
124’
190’ 83’
166’
1/4” EHS (665#) 3/16” EHS (399#)
150’
42’
144’
P/N: 55G90R180 190’ TOWER 32.4 OR 26.5 26.6
175’
232’
131’
201’ 87’
175’
5/16” EHS (1,120#) 3/16” EHS (399#)
158’
43’
152’
P/N: 55G90R190
104
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
55G
BPC55G
APL55G
15
1
1
GA55GD BASEFDNS ANCHOR 3
150’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 150
CB2G AB2
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 900’
12
600’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
16
1
1
3
1
3
GA55GD BASEFDNS ANCHOR 3
160’ ROHN 55G
CB2G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 160
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 950’
12
625’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
17
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 4
170’ ROHN 55G
CB2G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 170
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1525’
18
675’
6
18
6
12
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
18
1
1
3
1
3
GA55GD BASEFDNS ANCHOR 4
180’ ROHN 55G
CB2G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 180
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1625’
18
700’
6
18
6
12
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
19
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 4
190’ ROHN 55G
CB2G AB3
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 190
3/16EHS142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1700’
18
750’
6
18
6
12
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
3
3
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 185’ 139’
200’ TOWER 31.9 OR 26.2 24.2 245’ 212’
93’ 47’
185’
5/16” EHS (1,120#) 3/16” EHS (399#)
167’ 160’
P/N: 55G90R200
205’ 164’ 123’ 82’ 41’
220’ TOWER 31.1 OR 25.7 23.4 270’ 3/16” EHS 241’ (399#) 215’
5/16”EHS (1,120#)
194’ 181’
176’
P/N: 55G90R220
225’ 182’ 135’ 92’ 45’
240’ TOWER 30.3 OR 25.3 22.8 296’ 3/16” EHS 265’ (399#) 5/16” EHS (1,120#) 235’ 213’ 197’ 192’
P/N: 55G90R240
245’ 202’ 162’ 122’ 82’ 42’
260’ TOWER 29.6 OR 24.8 22.2 321’ 290’ 5/16” EHS (1,120#) 264’ 3/16” EHS (399#) 241’ 104’ 77’ 64’
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
208’
P/N: 55G90R260
ANCHORS & GROUNDING INCLUDED
55G
BPC55G
APL55G
20
1
1
GA55GD BASEFDNS ANCHOR 4
CB2G AB3
200’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 200
3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1800’
18
800’
6
18
6
12
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
22
1
1
1
3
3
GA55GD BASEFDNS ANCHOR 5
CB2G AB3
220’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 220
3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 3/4TBE&J 2650’
24
875’
6
24
6
15
GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
24
1
1
3
1
3
GA55GD BASEFDNS ANCHOR 5
CB3G AB3
240’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 240
3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 3/4TBE&J 2900’
24
950’
6
24
6
15
GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
26
1
1
6
3/16EHS
142265
BG2142
BG2146
5/16THH
3125’
1025’
30
6
30
7/16THH
1/2TBE&J
5/8TBE&J
6
6
12
3
3
1
INNER OUTER GA55GD BASE ANCHOR ANCHOR
CB3G AB2
AB3
260’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 260
CPC.5/.75 CPC1/1.25 3
3
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 3
3
2
3
6
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
1
105
G
GUYED TOWERS - 55G
S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 280’ TOWER 29.0 OR 24.4
265’
21.8
222’
347’ 315’ 5/16” EHS (1,120#) 284’ 3/16” EHS (399#) 260’
175’ 132’ 85’
110’ 82’
43’
70’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
224’
P/N: 55G90R280
ANCHORS & GROUNDING INCLUDED 300’ TOWER 28.4 OR 24.1
285’
21.2
242’
373’ 341’ 5/16” EHS (1,120#) 314’ 3/16” EHS (399#) 290’
202’ 162’ 122’ 82’ 42’
158’ 129’ 108’ 100’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
240’
P/N: 55G90R300
ANCHORS & GROUNDING INCLUDED 320’ TOWER 27.9 OR 23.8
305’
20.8
262’
398’ 366’ 5/16” EHS (1,120#) 334’ 3/16” EHS (399#) 308’ 1/4”EHS (665#) 160’ 129’ 108’
215’ 172’ 125’ 82’ 42’
100’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
256’
P/N: 55G90R320
ANCHORS & GROUNDING INCLUDED 340’ TOWER 27.4 OR 23.5
325’
20.4
282’ 242’ 202’ 162’
424’ 392’ 364’ 339’ 317’
122’ 82’ 42’
155’ 126’ 105’
TOWER PARTS INCLUDED
5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)
96’
GUYS & CONNECTIONS INCLUDED
272’
P/N: 55G90R340
ANCHORS & GROUNDING INCLUDED
106
INNER OUTER BASE ANCHOR ANCHOR
55G
BPC55G
APL55G
GA55GD
28
1
1
6
CB4G AB2
3/16EHS
142265
BG2142
BG2146
5/16THH
3350
1125’
30
6
30
7/16THH
1/2TBE&J
5/8TBE&J
6
6
12
AB3
280’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 280
CPC.5/.75 CPC1/1.25 3
3
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 6
3
3
2
3
55G
BPC55G
APL55G
GA55GD
30
1
1
7
CB4G AB2
3/16EHS
142265
BG2142
BG2146
5/16THH
4275’
1200’
36
6
36
7/16THH
1/2TBE&J
6
9
1
INNER OUTER BASE ANCHOR ANCHOR
AB3
300’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G90R 300
5/8TBE&J CPC.5/.75 CPC1/1.25 12
3
3
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX TBSAFETY 3/4x12PP 3
3
2
3
55G
BPC55G
APL55G
GA55GD
32
1
1
7
3/16EHS
1/4EHS
142265
BG2142
2250’
2250’
1275’
24
5/16THH
3/8THH
7/16THH
1/2TBE&J
24
12
6
9
6
1
INNER OUTER BASE ANCHOR ANCHOR
CB4G AB2 BG2144
AB3 BG2146
320’ ROHN 55G
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 320
12
6
12
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
3
2
3
55G
BPC55G
APL55G
GA55GD
34
1
1
8
CB4G AB2
3/16EHS
1/4EHS
142265
BG2142
BG2144
3325’
2425’
1350’
30
5/16THH
3/8THH
7/16THH
1/2TBE&J
30
12
6
9
3
1
INNER OUTER BASE ANCHOR ANCHOR
AB3 BG2146
340’ ROHN 55G
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 340
12
6
15
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
2
3
3
3
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D D E S I G N - 5 5 G 9 0 M P H R E V. G , 7 0 M P H R E V. F 360’ TOWER 27.0 OR 23.2
345’
20.0
302’ 255’ 212’ 168’
449’ 417’ 385’ 358’ 333’
126’ 84’ 42’
161’ 131’ 108’
TOWER PARTS INCLUDED
5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)
GUYS & CONNECTIONS INCLUDED
100’ 288’
P/N: 55G90R360
ANCHORS & GROUNDING INCLUDED
365’ 319’ 273’ 227’ 181’ 135’ 92’ 45’
380’ TOWER 26.6 OR 22.9 475’ 441’ 409’ 379’ 354’ 174’ 143’ 119’
19.6
TOWER PARTS INCLUDED
5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)
GUYS & CONNECTIONS INCLUDED
110’ 304’
P/N: 55G90R380
ANCHORS & GROUNDING INCLUDED
385’ 335’ 285’ 235’ 185’ 138’ 92’ 46’
400’ TOWER 26.1 OR 22.7 19.2 501’ 463’ 5/16” EHS 429’ (1,120#) 397’ 3/16” EHS (399#) 370’ 1/4”EHS (665#) 183’ 151’ 129’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
120’ 320’
P/N: 55G90R400
ANCHORS & GROUNDING INCLUDED
INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR
55G
BPC55G
APL55G
36
1
1
8
2
3/16EHS
1/4EHS
142265
BG2142
BG2144
3475’
2575’
1450’
30
5/16THH
3/8THH
7/16THH
1/2TBE&J
30
12
6
9
BG2146
AB4
360’ ROHN 55G
Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 360
12
6
15
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 3
CB5G AB2
CPC1/1.25 3
3
3
3
2
55G
BPC55G
APL55G
38
1
1
8
2
CB5G AB2
3/16EHS
1/4EHS
142265
BG2142
BG2144
BG2146
3175’
3275’
1525’
24
5/16THH
3/8THH
7/16THH
1/2TBE&J
24
18
6
9
INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR
AB4
380’ ROHN 55G
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G90R 380
18
6
15
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
3
3
3
2
55G
BPC55G
APL55G
40
1
1
8
2
CB5G AB2
3/16EHS
1/4EHS
142265
BG2142
BG2144
BG2146
2075’
4700’
1600’
18
24
5/16THH
3/8THH
7/16THH
1/2TBE&J
5/8TBE&J
18
24
6
9
15
INNER OUTER GA55GD APL1258UM BASE ANCHOR ANCHOR
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 3
3
2
3
AB4
400’ ROHN 55G
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng TBSAFETY Par t No: 55G90R 400
6
6
CPC1/1.25 3/4x12PP
3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
1
3
1
107
G
GUYED TOWERS - 55G
S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 95’
100’ TOWER 26.1 OR 20.4 19.2 124’ 3/16” EHS (399#)
63’ 102’ 33’
1/4” EHS (665#)
87’ 80’
P/N: 55G110R100
105’
110’ TOWER 25.4 OR 19.9 18.6 137’ 3/16” EHS (399#)
72’ 114’ 35’
1/4” EHS (665#)
95’ 88’
P/N: 55G110R110
115’
120’ TOWER 24.8 OR 19.6 18.2 150’ 3/16” EHS (399#)
77’ 123’ 38’
1/4” EHS (665#)
103’ 96’
P/N: 55G110R120
125’
130’ TOWER 24.2 OR 19.2 17.8 163’ 3/16” EHS (399#)
83’ 133’ 42’
1/4” EHS (665#)
112’ 104’
P/N: 55G110R130
135’ 101’
140’ TOWER 23.6 OR 18.9 17.2 175’ 151’
67’ 34’
131’
1/4” EHS (665#) 3/16” EHS (399#)
117’ 112’
P/N: 55G110R140
108
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
55G
BPC55G
APL55G
10
1
1
GA55GD BASEFDNS ANCHOR 3
100’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 100
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 600’
12
400’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
11
1
1
1
3
3
GA55GD BASEFDNS ANCHOR 3
110’ ROHN 55G
CB1G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 110
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 675’
12
450’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
12
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 3
120’ ROHN 55G
CB2G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 120
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 725’
12
500’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
13
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 3
130’ ROHN 55G
CB2G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 130
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 800’
12
525’
6
12
6
9
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
14
1
1
3
3
1
GA55GD BASEFDNS ANCHOR 4
140’ ROHN 55G
CB2G AB2
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 140
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J 1275’
18
575’
6
18
6
12
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
1
3
3
3
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 150’ TOWER 23.2 OR 18.7
145’
16.8 188’
108’
161’ 72’
140’
1/4” EHS (665#) 3/16” EHS (399#)
125’
36’
120’
P/N: 55G110R150 160’ TOWER 22.8 OR 18.4
155’
16.4 201’
116’
173’ 78’
150’
5/16” EHS (1,120#) 3/16” EHS (399#)
134’
39’
128’
P/N: 55G110R160 170’ TOWER 22.4 OR 18.2 16.2
165’
214’
124’
184’ 83’
159’
1/4” EHS (665#) 3/16” EHS (399#)
142’
41’
136’
P/N: 55G110R170 180’ TOWER 22.0 OR 18.0 15.8
175’
227’
142’
202’
105’
178’
72’
3/16” EHS (399#) 1/4” EHS (665#)
161’
35’
148’ 144’
P/N: 55G110R180
185’ 148’ 111’ 74’ 37’
190’ TOWER 21.7 OR 17.8 15.6 239’ 212’ 188’ 169’ 156’
3/16” EHS (399#) 5/16” EHS (1,120#) 1/4”EHS (665#)
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED GUYS & CONNECTIONS INCLUDED ANCHORS & GROUNDING INCLUDED
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
152’
P/N: 55G110R190
ANCHORS & GROUNDING INCLUDED
55G
BPC55G
APL55G
15
1
1
GA55GD BASEFDNS ANCHOR 4
150’ ROHN 55G
CB2G AB3
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 150
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 1375’
18
600’
6
18
6
12
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
16
1
1
1
3
3
GA55GD BASEFDNS ANCHOR 4
160’ ROHN 55G
CB2G AB3
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G110R 160
3/16EHS 142265 BG2142 BG2146 5/16THH 7/16THH 5/8TBE&J 1475’
18
650’
6
18
6
12
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
17
1
1
3
1
3
GA55GD BASEFDNS ANCHOR 4
170’ ROHN 55G
CB2G AB3
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 170
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 975’
12
1275’
12
12
12
12
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
18
1
1
1
3
3
GA55GD BASEFDNS ANCHOR 5
180’ ROHN 55G
CB3G AB3
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 180
3/16EHS 1/4EHS BG2142 BG2144 5/16THH 3/8THH 5/8TBE&J 1550’
18
1375’
12
18
12
15
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
3
1
3
55G
BPC55G
APL55G
GA55GD
19
1
1
5
3/16EHS
1/4EHS
142265
BG2142
BG2144
1650’
675’
775’
18
6
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
18
6
6
15
3
1
FDNS
BASE ANCHOR
CB3G AB3
190’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 190
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
3
3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
1
109
G
GUYED TOWERS - 55G
S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 195’ 156’ 117’ 78’ 39’
200’ TOWER 21.4 OR 17.6 13.2 252’ 3/16” EHS 223’ (399#) 5/16” EHS (1,120#) 198’ 1/4”EHS (665#)
178’ 165’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
160’
P/N: 55G110R200
ANCHORS & GROUNDING INCLUDED 220’ TOWER 20.8 OR 17.2 12.8
215’ 182’
278’ 253’ 5/16” EHS (1,120#) 228’ 3/16” EHS (399#) 209’ 1/4”EHS (665#) 94’ 70’
145’ 112’ 73’ 36’
60’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
176’
P/N: 55G110R220
ANCHORS & GROUNDING INCLUDED
235’ 201’ 167’ 133’ 99’ 66’ 33’
240’ TOWER 20.3 OR 16.9 12.4 303’ 278’ 5/16” EHS (1,120#) 254’ 3/16” EHS (399#) 234’ 1/4”EHS (665#) 127’ 104’ 87’ 80’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
192’
P/N: 55G110R240
ANCHORS & GROUNDING INCLUDED
255’ 219’ 183’ 147’ 111’ 75’ 38’
260’ TOWER 19.8 OR 16.6 12.0 329’ 302’ 5/16” EHS (1,120#) 277’ 3/16” EHS (399#) 255’ 1/4”EHS (665#) 142’ 116’ 96’ 88’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
208’
P/N: 55G110R260
ANCHORS & GROUNDING INCLUDED
110
FDNS GA55GD BASE ANCHOR
55G
BPC55G
APL55G
20
1
1
5
3/16EHS
1/4EHS
142265
BG2142
BG2144
1750’
725’
825’
18
6
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
18
6
6
15
CB3G AB3
200’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G110R 200
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
22
1
1
6
3/16EHS
1/4EHS
142265
BG2142
1925’
825’
900’
24
5/16THH
3/8THH
7/16THH
1/2TBE&J
24
6
6
6
3
3
1
INNER OUTER GA55GD BASE ANCHOR ANCHOR
CB4G AB2 BG2144
AB3 BG2146
220’ ROHN 55G
Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 220
6
6
12
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
2
55G
BPC55G
APL55G
24
1
1
7
3/16EHS
1/4EHS
142265
BG2142
1775’
1700’
975’
24
5/16THH
3/8THH
7/16THH
1/2TBE&J
24
12
6
9
3
3
3
1
INNER OUTER GA55GD BASE ANCHOR ANCHOR
CB4G AB2 BG2144
AB3 BG2146
240’ ROHN 55G
Al l par ts shown i n tabl e are i nc l uded when order i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 240
12
6
12
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
3
2
55G
BPC55G
APL55G
26
1
1
7
3/16EHS
1/4EHS
142265
BG2142
BG2144
1500’
2300’
1050’
18
18
5/16THH
3/8THH
7/16THH
18
18
6
3
3
1
INNER OUTER GA55GD BASE ANCHOR ANCHOR
CB5G AB2
1/2TBE&J 5/8TBE&J 9
12
AB3 BG2146
260’ ROHN 55G
Al l par ts shown i n tabl e are i nc l uded when order i ng TBSAFETY Par t No: 55G110R 260
6
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
2
3
3
3
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D D E S I G N - 5 5 G 1 1 0 M P H R E V. G , 9 0 M P H R E V. F 275’ 241’ 207’ 173’ 139’ 105’ 71’ 35’
280’ TOWER 19.4 OR 16.4 355’ 329’ 305’ 283’ 264’ 134’ 110’ 91’
11.6
TOWER PARTS INCLUDED
5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)
84’
GUYS & CONNECTIONS INCLUDED
224’
P/N: 55G110R280
ANCHORS & GROUNDING INCLUDED
295’ 259’ 223’ 187’ 151’ 115’ 79’ 41’
300’ TOWER 19.0 OR 16.1 380’ 353’ 328’ 304’ 284’ 152’ 127’ 108’
11.2
TOWER PARTS INCLUDED
5/16” EHS (1,120#) 3/16” EHS (399#) 1/4”EHS (665#)
GUYS & CONNECTIONS INCLUDED
100’ 240’
P/N: 55G110R300
ANCHORS & GROUNDING INCLUDED
INNER OUTER GA55GD BASE ANCHOR ANCHOR
55G
BPC55G
APL55G
28
1
1
8
3/16EHS
1/4EHS
142265
BG2142
2825’
2025’
1150’
30
5/16THH
3/8THH
7/16THH
1/2TBE&J
30
12
6
9
CB5G AB2 BG2144
AB4 BG2146
280’ ROHN 55G
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 280
12
6
15
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
3
2
55G
BPC55G
APL55G
30
1
1
8
3/16EHS
1/4EHS
142265
BG2142
1675’
2500’
2350’
18
5/16THH
3/8THH
7/16THH
1/2TBE&J
18
18
12
9
3
3
1
INNER OUTER GA55GD BASE ANCHOR ANCHOR
CB5G AB2 BG2144
AB4 BG2146
300’ ROHN 55G
Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng 5/8TBE&J TBSAFETY Par t No: 55G110R 300
18
12
15
6
GAC3455TOP GAC5655TOP AGK1GGX BGK2GGX CPC.5/.75 CPC1/1.25 3/4x12PP 3
3
2
3
3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
3
1
111
G
GUYED TOWERS - 55G
S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 100’ TOWER 18.7 OR 14.6
95’
124’
18.0
5/16” EHS (1120#) 3/16” EHS (399#) 102’ 1/4” EHS (665#)
63’
33’
87’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
80’
P/N: 55G130R100
ANCHORS & GROUNDING INCLUDED 110’ TOWER 18.2 OR 14.2 16.0 137’ 5/16” EHS (1120#) 3/16” EHS (399#) 114’ 1/4” EHS (665#)
105’
72’
35’
95’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
88’
P/N: 55G130R110
ANCHORS & GROUNDING INCLUDED 120’ TOWER 17.7 OR 14.0 14.0 150’ 5/16” EHS (1120#) 3/16” EHS (399#) 123’ 1/4” EHS (665#)
115’
77’
38’
103’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
96’
P/N: 55G130R120
ANCHORS & GROUNDING INCLUDED 130’ TOWER 17.3 OR 13.8 12.0 163’ 5/16” EHS (1120#) 1/4” EHS (665#) 133’
125’
83’
42’
112’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
104’
P/N: 55G130R130
ANCHORS & GROUNDING INCLUDED
112
FDNS GA55GD BASE ANCHOR
55G
BPC55G
APL55G
10
1
1
3
3/16EHS
1/4EHS
142265
BG2142
300’
325’
400’
6
BG2146
5/16THH
3/8THH
7/16THH
6
6
6
6
CB2G AB2 BG2144
100’ ROHN 55 G
All par ts shown in table are i nclu de d when order ing 1/2TBE&J 5/8TBE&J Par t No: 55G130R100
6
6
3
GAC3455TOP AGK1GGX BGK2GGX CPC.5/.75 TBSAFETY 3/4x12PP 3
3
1
3
55G
BPC55G
APL55G
11
1
1
3
3/16EHS
1/4EHS
142265
BG2142
BG2144
325’
375’
450’
6
6
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
6
6
6
9
3
1
FDNS GA55GD BASE ANCHOR CB2G AB3
110’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R110
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
3
1
3
55G
BPC55G
APL55G
12
1
1
3
3/16EHS
1/4EHS
142265
BG2142
BG2144
350’
400’
500’
6
6
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
6
6
6
9
3
1
FDNS GA55GD BASE ANCHOR CB2G AB3
120’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R120
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
1
3
55G
BPC55G
APL55G
13
1
1
1/4EHS
142265
BG2144
BG2146
800’
525’
12
6
3/8THH
7/16THH
12
6
3
3
FDNS GA55GD BASE ANCHOR 3
CB2G AB3
130’ ROHN 55G All par ts shown in table are i nclu de d when order ing Par t No: 55G130R130
5/8TBE&J TBSAFETY 9
1
3
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 3/4x12PP 3
1
3
3
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 135’ 101’ 67’ 34’
140’ TOWER 16.9 OR 13.6 11.0 175’ 5/16” EHS (1120#) 151’ 1/4” EHS (665#) 131’ 3/16” EHS (399#) 117’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
112’
P/N: 55G130R140
ANCHORS & GROUNDING INCLUDED
145’ 108’
150’ TOWER 16.6 OR 13.4 10.0 188’ 161’
72’ 36’
140’
TOWER PARTS INCLUDED
5/16” EHS (1120#) 1/4” EHS (665#) 3/16” EHS (399#)
125’
GUYS & CONNECTIONS INCLUDED
120’
P/N: 55G130R150
ANCHORS & GROUNDING INCLUDED
155’ 116’ 78’ 39’
160’ TOWER 16.3 OR 13.2 9.8 201’ 5/16” EHS (1120#) 173’ 1/4” EHS (665#) 150’ 3/16” EHS (399#) 134’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
128’
P/N: 55G130R160
ANCHORS & GROUNDING INCLUDED
165’ 124’ 83’ 41’
170’ TOWER 16.0 OR 13.0 9.6 214’ 5/16” EHS (1120#) 184’ 1/4” EHS (665#) 159’ 3/16” EHS (399#) 142’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
136’
P/N: 55G130R170
ANCHORS & GROUNDING INCLUDED
FDNS GA55GD BASE ANCHOR
55G
BPC55G
APL55G
14
1
1
4
3/16EHS
1/4EHS
142265
BG2142
BG2144
375’
900’
575’
6
12
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
6
12
6
3
CB3G AB3
140’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 140
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
3
1
3
55G
BPC55G
APL55G
15
1
1
4
3/16EHS
1/4EHS
142265
BG2142
BG2144
400’
975’
600’
6
12
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
6
12
6
3
3
1
FDNS GA55GD BASE ANCHOR CB3G AB3
150’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 150
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
3
1
3
55G
BPC55G
APL55G
16
1
1
4
3/16EHS
1/4EHS
142265
BG2142
BG2144
450’
1050’
650’
6
12
BG2146
5/16THH
3/8THH
7/16THH
5/8TBE&J
6
6
12
6
12
3
1
FDNS GA55GD BASE ANCHOR CB3G AB3
160’ ROHN 55G Al l par ts shown i n tabl e are i nc l ud ed when ord er i ng Par t No: 55G130R 160
GAC5655TOP AGK1GGX BGK2GGX CPC1/1.25 TBSAFETY 3/4x12PP 3
3
1
3
55G
BPC55G
APL55G
17
1
1
4
3/16EHS
1/4EHS
142265
BG2142
BG2144
475’
1100’
700’
6
12
BG2146
5/16THH
3/8THH
7/16THH
3/4TBE&J
6
6
12
6
12
3
1
FDNS GA55GD BASE ANCHOR CB3G AB4
170’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 170
GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 3
1
3
3
3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
1
113
G
GUYED TOWERS - 55G
S TA N D A R D D E S I G N - 5 5 G 1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F 180’ TOWER 15.8 OR 12.9
175’
9.2 227’
142’
5/16” EHS (1120#) 202’ 1/4” EHS (665#) 178’ 3/16”EHS 161’ (399#)
105’ 72’ 35’
148’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
144’
P/N: 55G130R180
ANCHORS & GROUNDING INCLUDED 190’ TOWER 15.5 OR 12.7 9.0
185’
239’
152’
5/16” EHS (1120#) 215’ 1/4” EHS (665#) 191’
115’ 82’
173’
41’
157’
TOWER PARTS INCLUDED
GUYS & CONNECTIONS INCLUDED
152’
P/N: 55G130R190
ANCHORS & GROUNDING INCLUDED
114
FDNS GA55GD BASE ANCHOR
55G
BPC55G
APL55G
18
1
1
5
3/16EHS
1/4EHS
142265
BG2142
BG2144
1000’
1225’
725’
12
12
BG2146
5/16THH
3/8THH
7/16THH
3/4TBE&J
6
12
12
6
15
CB3G AB4
180’ ROHN 55G Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 180
GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 TBSAFETY 3/4x12PP 1
3
1
3
3
3
55G
BPC55G
APL55G
GA55GD
BASE ANCHOR
19
1
1
5
1/4EHS
142265
BG2144
BG2146
190’ ROHN 55G
2350’
775’
24
6
3/8THH
7/16THH
Al l par ts shown i n tabl e are i nc l uded when order i ng Par t No: 55G130R 190
24
6
FDNS
CB4G AB4
3/4TBE&J TBSAFETY 15
3
GAC5755TOP AGK1GGX BGK2GGX CPC1.5/2 3/4x12PP 3
1
3
3
1
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
G
GUYED TOWERS - 55G
PA R T S & A CC E S S O R I E S
TOP PLATE APL55G FOR MOUNTING BEACON OR LIGHTNING ROD.
BEARING PLATE BPL55G
ACCESSORY SHELF AS455G
CONVERTS STANDARD SECTION TO A TOP SECTION. HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 (3” O.D.) THRUST BEARING.
FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.
TOP MOUNT 55TDMKD - NO MAST 55TDM2S3KD - 2 3/8” O.D. MAST 55TDM25S3KD - 2 7/8” O.D. MAST 55TDM3S3KD - 3 1/2” O.D. MAST 55TDM35S3KD - 4” O.D. MAST 55TDM4S3KD - 4 1/2” O.D. MAST MOUNTING TUBE PROVIDED IS 7’.
TAPERED BASE* 55TG - STANDARD 55TGIA - USE WITH A4197L BASE INSULATOR
CONCRETE BASE PLATE BPC55G* LIGHTNING ROD LRCL
5’ COPPER CLAD, MOUNTS TO APL55G.
FOR USE WITH 3/4X12PP PIER PIN EMBEDDED IN CONCRETE. CONCRETE BASE PLATE IS TO BE USED FOR BRACKETED AND GUYED APPLICATIONS ONLY.
PIER PIN 3/4X12PP
55TGIAA - USE WITH
A4722B BASE INSULATOR
FOR USE WITH BPC55G EMBEDDED IN CONCRETE.
INSULATOR AND PIER PIN MUST BE ORDERED SEPARATELY.
PIER PIN MUST BE ORDERED SEPARATELY, UNLESS BEING PURCHASED AS PART OF A COMPLETE TOWER KIT.
Adjustable 2.5’ - 3.0’
5’ SHORT BASE SB55G
FLAT ROOF MOUNT FR55G* BOLTS DIRECTLY TO FLAT ROOF SURFACE.
FOR EMBEDMENT IN CONCRETE.
SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.
FACE MOUNT DM55G2 - 2 3/8” O.D. 5’ LONG DM554 - 4 1/2” O.D. 5’ LONG
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
115
G
GUYED TOWERS - 55G
PA R T S & A CC E S S O R I E S
HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 18” - 36” FROM WALL.
TORQUE ARM STABILIZER ASSEMBLY TA55 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER.
THRUST BEARING TB3 - SUPPORTS UP TO 2” O.D. MAST. TB4 - SUPPORTS UP TO 3” O.D. MAST. MOUNTS TO BPL55G.
ANTI-CLIMB PANELS 455ACL3
TORQUE BAR TB55D
OPTIONAL, FOR USE WITH GA55GD. REQUIRES (1) 3/8” SHACKLE FOR EACH BAR.
WORK PLATFORM WP55G SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.
GUY BRACKET GA55GD MOUNTS TO TOWER AT ANY HORIZONTAL BRACE.
SAFETY RING SR55 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.
THREE ANTI-CLIMB PANELS BOLT TO STANDARD TOWER SECTION.
SAFETY CABLE SYSTEM ORDERING INFORMATION
CLIMBING HARNESS TTFBH-4D JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
116
SAFETY CABLE SLIDER WITH CARABINEER TT-WG-500-W/SMC
TOWER HEIGHT 50’ 100’ 150’ 200’ 250’ 300’ 350’ 400’
PART NUMBER TT0504555 TT1004555 TT1504555 TT2004555 TT2504555 TT3004555 TT3504555 TT4004555
SAFETY CABLE SLIDER AND CLIMBING HARNESS MUST BE ORDERED SEPARATELY.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
G
GUYED TOWERS - 55G
A N C H O R I N F O R M AT I O N 81”
12”
3/8” CL of hole to edge of plate = 1”
P/N STAMPED HERE
3/4”
4” x 4” x 3/8” angle
2”
GAC3455TOP
11/16”
120”
12”
1/2” CL of hole to edge of plate = 1 1/4”
P/N STAMPED HERE
1 1/4”
5” x 5” x 3/8” angle
2 1/2” 13/16”
GAC5655TOP 168”
12”
3/4” CL of hole to edge of plate = 1 1/4”
P/N STAMPED HERE
1 7/16”
5” x 5” x 3/8” angle
3” 15/16”
GAC5755TOP REV G BASE GROUNDING BGK2GGX
REV G ANCHOR GROUNDING AGK1GGX
Attach to leg with supplied leg clamp Ground Wire Clamp
Ground Wire
Ground Rod Clamp 6” Min. Ground Rod
Ground Rod Clamp
6” Min.
Ground Rod, 3 provided (to be installed at 120o separation at 20’ spacing.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
117
G
GUYED TOWERS - 55G
S TA N D A R D A N C H O R B LO C K S
Anchor rod
Ground Line
All around stirrups equally spaced 12” O.C. anchored with 90 hooks around a horizontal bar Additional bar at center-line each side, when required
o
Top and bottom horizontal bars equally spaced
A B
C
D
Refer to page 119 for anchor rod installation angles.
118
Block
Anchor Dimensions (in.) B A D C
AB2
4’ - 0” 1‘ - 6” 4‘ - 0“ 6’ - 0”
AB3
6’ - 0” 1’ - 6” 3’ - 0” 6’ - 0”
AB4
6‘ - 0” 1’ - 6” 4‘ - 0“ 9’ - 0”
AB5
8’ - 0” 2’ - 0” 3’ - 0” 10’ - 0”
AB6
8’ - 0” 2’ - 0” 4’ - 0” 10’ - 0”
Horizontal Bars (Qty. & Size) (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #6 Bars, Top Layer (4) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (5) #6 Bars, Top Layer (5) #6 Bars, Bottom Layer (0) Additional Bar, Each Side (4) #7 Bars, Top Layer (4) #7 Bars, Bottom Layer (1) Additional Bar, Each Side (5) #7 Bars, Top Layer (5) #7 Bars, Bottom Layer (1) Additional Bar, Each Side
Stirrup Size Concrete Vol. & Spacing (Cu. Yds.) #3 @ 12” O.C. 1.33 Per Block 4.0 Total for 3 #3 @ 12” O.C. 1.0 Per Block 3.0 Total for 3 #4 @ 12” O.C. 2.0 Per Block 6.0 Total for 3 #4 @ 12” O.C. 2.22 Per Block 6.7 Total for 3 #4 @ 12” O.C. 2.96 Per Block 8.9 Total for 3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 55G
G
A N C H O R R O D I N S TA L L AT I O N A N G L E S
120
Rod Angle (in degrees)
o
Tower Plan
Anchor Rod Angle
55G | 90MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’ 320’ 340’ 360’ 380’ 400’
Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 42 GAC3455TOP 42 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 39 GAC3455TOP 39 GAC3455TOP 38 GAC3455TOP 38 GAC5655TOP 40 GAC5655TOP 40 GAC5755TOP 38 GAC5755TOP 37 GAC3455TOP 43 GAC5655TOP 42 GAC3455TOP 42 GAC5655TOP 42 GAC3455TOP 39 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 40 GAC5655TOP 42 GAC3455TOP 38 GAC5655TOP 42
Ground Line
55G | 110MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’ 200’ 220’ 240’ 260’ 280’ 300’
Inner Outer Rod Outer Inner Rod Rod Rod Number Angle Number Angle GAC3455TOP 41 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 40 GAC3455TOP 38 GAC5655TOP 38 GAC5655TOP 39 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC5655TOP 38 GAC3455TOP 42 GAC5655TOP 43 GAC3455TOP 40 GAC5655TOP 44 GAC3455TOP 41 GAC5655TOP 44 GAC3455TOP 40 GAC5655TOP 43 GAC3455TOP 39 GAC5655TOP 43
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC
55G | 130MPH Tower Height 100’ 110’ 120’ 130’ 140’ 150’ 160’ 170’ 180’ 190’
Rod Rod Number Angle GAC3455TOP 41 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5655TOP 40 GAC5755TOP 38 GAC5755TOP 38 GAC5755TOP 37
119
G
GUYED TOWERS - 55G
S TA N D A R D B A S E P I E R S Pier Pin 4” Projection 6”
Grade
(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps E
No. 4 Circular ties, 3” Max. O.C. with 24” laps Vertical re-bars equally spaced with 90 hooks at bottom (for CB5G)
D
Roughen construction joint to a full amplitude of 1/4”
C
Foundation Pad
F
Horizontal reinforcing steel bars equally spaced each way
ELEVATION VIEW B
A
B
Alternate Square Pier
No. 4 Circular ties, 3” O.C. with 24” laps CL
A
Vertical bars equally spaced
CL
PLAN VIEW
Base
120
A
B
C
D
E
F
Concrete Vol. Vertical Bars (Cu. Yds.) (No. & Size) Round Pier
Horiz. Bars in Pad (No. & Size)
CB1G* 2’ - 6” 2’ - 6” N/A 4’ - 0” N/A
N/A
1.0
(8) #7
NONE
CB2G
3’ - 0” 3’ - 0” N/A 4’ - 0” N/A
N/A
1.2
(10) #7
NONE
CB3G
3’ - 6” 3’ - 6” N/A 4’ - 0” N/A
N/A
1.6
(12) #7
NONE
CB4G
4’ - 0” 4’ - 0” N/A 4’ - 0” N/A
N/A
2.1
(12) #8
NONE
CB5G
2’ - 0” 4’ - 0” 1’ - 0” 4’ - 0” 3’ - 3” 1’ - 3”
1.1
(8) #6
(5) #5
(Total of 10)
* Square pier option must be used for CB1G. Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard © 2011 ROHN PRODUCTS LLC