BUILDING SERVICES (ARC 2423)
PROJECT 2 - APPLICATION OF BUILDING SERVICES CHEN ROU ANN 1001G76463
SCHOOL OF ARCHITECTURE
MS SATEERAH
COLD WATER AND HOT WATER SUPPLY SYSTEM
Washroom 1:50
HT
WATER SUPPLY SYSTEM BY-LAW UBBL 1984 UNDER UNDER UBBL BY-LAW 48 Suitable measures should be taken to prevent penetration of dampness and moisture into the building.
From roof
19MMØ COPPER PIPE AS HOT WATER
UNDER UBBL BY-LAW 123 Allowing adequate accommodation of the pipes, stop cocks to enable repairs and access openings to ducts or enclosure
LEGEND
GROUND FLOOR
WATER METER F
FILTER
GV
Incoming water from SYABAS
WATER TANK
SC
HOT WATER
GATE VALVE
Kitchen sink
Water meter Measure volume of water used
STOP COCK SHOWER WATER TANK SHOWER HEAD KITCHEN SINK TOILET BASIN WATER CLOSET COLD WATER
FIRST FLOOR
Shower head
HOT WATER
Gate valve Allow or prevent flow of liquids
ROOF LEVEL
SC HT
SCHEMATIC DIAGRAM OF WATER SUPLY SYSTEM
25MMØ DROPPER UPVC CLASS D DISTRIBUTION PIPE
19MMØ COPPER PIPE AS HOT WATER
20MMØ CW PI PE
SC
Stop cock Restrict or isolate flow of liquid through a pipe
ROOF LEVEL
SERVICE PIPE
20MMØ CW PIPE
SC
SC
SC
GV
SC 20MMØ CW PI PE
F
32MMØ UPVC CLASS D PIPE
GV GROUND LEVEL
GROUND LEVEL
GT
DRAINAGE SYSTEM
TO INDAH WATER KONSORTIUM
A drainage system is one that is used to drain foul water and surface water so that there will be no overloading problems in periods of heavy rain.
DRAIN SUMP
MH
MH
LEGEND GUTTER
GT
GUTTER
GT
DRAINAGE PIPE
GT
WATER FLOW DIRECTION
MH
MAN HOLE DRAINAGE SUMP
DRAIN SUMP
SEWAGE AND SANITARY SYSTEM SEWARAGE SYSTEM BY-LAW Law of Malaysia Act 133, Street Drainage and Building Act 1974 No water pivpe, stack pipe or down spout used for conveying surface water from any premises shall be used or be permitted to serve or to act as a ventilating shaft to any drain or sewer
TRANSFERED TO IWK F
LEGEND TRAP
GT
MAN HOLE
MH
SEWAGE PIPE TO BE CONNECTED TO MAIN SEWER LINE
MH ST
MH
MH
GT
WATER CLOSET TOILET BASIN KITCHEN SINK
150MMØ UPVC SOL PIPE
ROOF LEVEL
SEPTIC TANK ST
SCHEMATIC DIAGRAM OF WATER SEWAGE SYSTEM WATER CLOSET
TOILET BASIN
KITCHEN SINK
GROUND LEVEL SHOWER FLOOR TRAP 150MMØ UPVC SOL PIPE 150MMØ UPVC SOL PIPE
T-trap Installed in sewer pipe to prevent excess sewage from excaping from sewage system
Kitchen sink trap GT
MH1
MH2
MH3 ST
ELECTRICAL SUPPLY SYSTEM LEGEND EXHAUST FAN 13A SOCKET POINT WALL MOUNTED LIGHT CEILING LIGHT
EL
EL
EL
EMERGENCY LIGHT FAN
EL
1 GANG SWITCH 2 GANG SWITCH 3 GANG SWITCH
ELECTRICAL BY-LAWS ELECTRICITY SUPPLY ACT 1997 (ACT 447) P.U. (A) 38/94 ELECTRICITY REGULATION 1994 REGULATION 15 – Apparatus, conductor, accessory etc Any conductor or apparatus that is exposed to the weather, water, corrosion, undue heating or used in inflammable surroundings or in an explosive atmosphere shall be constructed or protected in such a manner as to prevent danger REGULATION 16- Switch, switch fuse, fuse switch, circuit breaker, contractor, fuce, etc ((3) Any fuse or cuicuit breaker shall be (a) constructed and arranged in such a manner so as to break the current when it exceed a given value for a sufficient time to prevent danger and (b) constructed guarded or placed in a manner as to prevent danger of overheating, arcing or from the scattering of hot metal or other substance.
GROUND FLOOR
Wall mounted light
3 gang switch
Ceiling Light
EL
EL
DISTRIBUTION BOX
Floor Trap Installed in the floor to collect and drain used water from floor
Distribution box A component of an electricity supply system which devides an electrical power feed into subsidiary circuits, providing protective fuse or circuit breaker for each cuicuit
13A socket point
FIRST FLOOR
Ceiling fan
Exhaust fan