Construction Documents

Page 1

PROJECT INFORMATION

KNOXVILLE

PROJECT NAME: DOWNTOWN CHILD CARE PROJECT ADDRESS: 515 UNION AVE, KNOXVILLE TN 37902 PROJECT OWNER: UNIVERSITY OF TENNESSEE, COLLEGE OF INTERIOR ARCHITECTURE & DESIGN OWNER CONTACT INFORMATION: ARCHDESIGN.UTK.EDU (865) 974 - 5265

INDEX OF DRAWINGS SHEET NUMBER

G001 G002 G003 A111 A121 A131 A141 A311 A511 A512 A811

PROJECT DESCRIPTION

INTERIOR RENOVATION CONSISTING THREE EXISTING SUITES TO BE COMBINED INTO ONE IN THE DAYLIGHT BUILDING. THE EXTERIOR CONSISTS OF A HISTORIC FACADE THAT WILL REMAIN UNTOUCHED. EXISITING INTERIOR WALLS WILL BE DEMOLISHED AND THE SLOPED FLOOR WILL BE LEVELED OUT. EXISTING WATER CLOSETS WILL BE REMOVED AND PLACED ELSEWHERE AS WELL AS ADDING A KITCHEN. FIRE RATED WALLS WILL BE BROUGHT UP TO CODE AND ACOUSTIC WALLS WILL BE PLACED WHERE NECESSARY.

NAME

TITLE SHEET LIFE SAFETY PLAN FIRE RATED WALLS FLOOR PLAN REFLECTED CEILING PLAN FINISH PLAN FURNISHINGS PLAN INTERIOR ELEVATIONS DETAILS DETAILS OPENINGS

DESIGNER INFORMATION

PROJECT DESIGNER: RACHEL SMITH CONTACT INFORMATION: WBC642@VOLS.UTK.EDU VICINITY MAP

GENERAL INFORMATION: N

SHELL BUILDING CHARACTERISTICS LEGEND

BRICK EXTERIOR WITH LIMESTONE BASED COLUMNS COVERED IN BRICK SEPARATING THE SPACE INTO 9 BAYS MIXED OCCUPANCY BUSINESS PRIMARY : GROUP E SECONDARY : R-2 SEPARATED BY 2 HOUR FIRE RATED WALLS, FLOOR, AND CEILING CONTRUCTION TYPE III B SPRINKLERED BUILDING FLOOR AREA : 4271 SQ FT 3 STORIES WITH BASEMENT

1 100

DOOR TAG ROOM NUMBER

DAYLIGHT DAYCARE CENTER

ADA 5-FOOT TURNING RADIUS X#

WALL TAG

ROOM NO.

PROJECT ADDRESS: 515 UNION AVENUE KNOXVILLE, TN 37902

NAME

PROJECT SUITE CHARACTERISTICS BUSINESS GROUP E : R-2 FIRE SEPARATION REQUIRED : 2 HOUR FIRE RATED WALL OCCUPANT LOAD: 119 OCCUPANTS NUMBER OF EXITS REQUIRED : 2

STATE CHILD CARE REGULATIONS TYPE OF CHILD CARE: CHILD CARE CENTER ROOMS AGE RANGE GROUP 1 : INFANT / TODDLER AGES 6 WEEKS - 30 MONTHS GROUP 2 : PRESCHOOL AGES 30 MONTHS - 5 YEARS GROUP 3 : GRADE SCHOOL AGES 5 - 12 YEARS MAXIMUM GROUP SIZE : 10 PER ROOM CAREGIVER RATIO 1 CHILD CAREGIVER MAX OF 15 IN GROUP & NO CHILD IS PRESENT UNDER 3 YEARS OLD 2 CHILD CAREGIVER MAX OF 15 IN GROUP WITH 9 CHILDREN PRESENT UNDER 3 YEARS OLD, BUT NO MORE THAN 4 PRESENT UNDER 2 YEARS OLD 3 CHILD CAREGIVER MAX OF 15 CHILDREN OF 10 OR MORE ARE UNDER 3 YEARS OLD ROOM AREA : 580 SQ FT ROOM AREA RATE : 30 SQ FT PER CHILD

101 102 103 104 105 106 107 108 109 110 111 112 113 114 115

DIRECTOR'S OFFICE RESTROOM - UNISEX LAUNDRY KITCHENETTE HVAC INFANT/TODDLER SPACE HVAC RESTROOM - UNISEX PRESCHOOL SPACE HVAC RESTROOM - UNISEX GRADE SCHOOL SPACE HVAC RESTROOM - UNISEX LOBBY

DESIGN FIRM: UT SCHOOL OF INTERIOR ARCHITECTURE 1715 VOLUNTEER BOULEVARD KNOXVILLE, TN 37996 865- 974 5265 FOR REVIEW - NOT FOR CONSTRUCTION

BUILDING CODE REGULATION INFORMATION

JURISDICTION: CITY OF KNOXVILLE APPLICABLE CODES AND STANDARDS:

LOCATION WITHIN CITY

N

• 2009 ICC / ANSI A117.1 • 2018 INTERNATIONAL ENERGY CONSERVATION CODE AS ADOPTED BY CITY ORDINANCE 0-181-2018 • 2018 INTERNATIONAL BUILDING CODE AS ADOPTED BY CITY ORDINANCE 0-180-2018 • 2018 INTERNATIONAL EXISTING BUILDING CODE AS ADOPTED BY CITY ORDINANCE 0-179-2018 • 2018 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY CITY ORDINANCE 0-182-2018 • 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE AS ADOPTED BY CITY ORDINANCE 0-173-2018 • 2017 EDITION OF THE NATIONAL ELECTRICAL CODE AS ADOPTED BY CITY ORDINANCE 0-176-2018 • 2018 EDITION OF THE INTERNATIONAL FUEL GAS CODE AS ADOPTED BY CITY ORDINANCE 0-178-2018 • 2018 EDITION OF THE INTERNATIONAL MECHANICAL CODE AS ADOPTED BY CITY ORDINANCE 0-177-2018 • 2018 EDITION OF THE INTERNATIONAL PLUMBING CODE AS ADOPTED BY CITY ORDINANCE 0-175-2018 • 2018 EDITION OF THE INTERNATIONAL PROPERTY MAINTENANCE CODE AS ADOPTED BY CITY ORDINANCE 0-174-2018 • KNOXVILLE CODE OF ORDINANCES: CHAPTER 6 BUILDINGS AND BUILDING REGULATIONS, ARTICLE I, SECTION 6-5. FIRE DISTRICT IN ADDITION, THE FIRE INSPECTION BUREAU REVIEWS PLANS FOR COMPLIANCE WITH: • 2018 INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS AS ADOPTED BY CITY ORDINANCE 0-171-2018

KEY PLAN

PROJECT AREA

SHEET ISSUE DATE:

Issue Date

REVISIONS NO.

DATE

DESCRIPTION

PROJECT NUMBER

N KEY PLAN

N

TITLE SHEET

G001

5/6/2019 11:07:16 PM