Decorative Radiators
Comfortable Indoor Ventilation
Heating & Cooling Ceiling Systems
Always the best climate for
RADIATORS AND TOWEL WARMERS For central heating, electric and dual energy installations
Zehnder Professional Catalogue January 2019 v1
Clean Air Solutions
CONTENTS
Bathrooms Zehnder’s Bathroom towel radiators range; from the simply practical to our affordable designer range, suitable for central heating, electric and dual energy installations.
Page 6
Zehnder Aura
Page 14
Page 8
Zehnder Aura electric
Page 16
Page 10
Zehnder Aura Bow
Page 18
Page 12
TIP: All towel rails should be wiped dry as those in a damp or condensation laden atmosphere may suffer from superficial corrosion if not dried regularly. If this is the case, using a industry recommended chrome polish will remove early stages of this and restore the surface finish.
A carefully selected range of quality products at very competitive prices A wide choice of stock sizes available for immediate delivery 5 year warranty for all centrally heated steel products 10 year warranty for all centrally heated aluminium and stainless steel products
Zehnder Klaro
Page 20
All products supplied with brackets and air vents as standard Made-to-measure options included or available on request
Zehnder Muralis
Zehnder Stellar
Zehnder Stellar Spa
A comprehensive colour range available for selected products
Zehnder Zeta
Heat loss calculator to estimate the heat requirements for your room - see page 64
Living Zehnder’s comprehensive range of central heating and electric radiators for living areas, provides a complete heating solution for the home at very competitive prices.
Page 22
Page 26
Page 28
Page 30
Page 32
Expert technical back-up available Full technical details of all products available on our website: www.prorange.zehnder.co.uk
Zehnder Charleston
Page 34
Zehnder Charleston m2m
Page 36
Zehnder Kleo
Zehnder Lyta-S
Zehnder Lyta-T
All outputs tested to the European standard EN442 Symbol Key
Page 38
Page 40
Page 40
Central heating Suitable for domestic water Electric radiators
NEW
Zehnder Roda
Dual energy radiators
NEW
Zehnder Roda m2m
Zehnder Stana
Zehnder Alura
22
Zehnder Charleston Electric and Electric Plinth
m2m radiators
10 10
55
Colour
Extractor Fans, Accessories & Technical
2 5 10 10 2 2235 5510 10 DAY DAY
Page 42
Page 48
Page 49
DAY DAY
3-5 3-5
DAY DAY
5-7 5-7
14 14
Years warranty
DAY DAY
DAY
WEEKS WEEKS DAY
3-5 3-5 5-7
3-5
DAY
3-5
WEEKS WEEKS DAY
DAY DAY DAY
3-5 3-5 5-7
4-6 4-6 14
DAY DAY DAY
5-7 5-7 14
DAY WEEKS
17 3-5
Extractor fans
Valves, dual energy Technical and electric products specifications
WEEKS
WEEKS
DAY DAY
Delivery 1414 weeks applies to non-stocked items
DAY
DAY DAY WEEKS WEEKS
17 17 3-5 3-5
All products 20 4-6 are CE approved.
WEEKS
3-5
20 20 *applies to stock items only
DAY WEEKS
17 3-5 3-5
Delivery working days DAY DAY
WEEKS WEEKSWEEKS
DAY WEEKS WEEKS
DAY DAY
All central heating 20 products 2020 certified to EN442. 4-6 4-6 3-5 3-5 4-6
STOCK: All products listed in bold black type are stocked items.
January 2019
3
ECO DESIGN
ECO DESIGN
Eco Design Regulations for electric heating Since 1st January 2018, all electric local space heaters manufactured for sale in the EU must comply with a minimum efficiency standard under Lot 20 of the Energy Efficiency Directive. This is one of the biggest changes the electric heating industry has experienced in decades.
Towel warmers (less than 250W) are not included in the scope of the directive.
What exactly is Lot 20?
What are the benefits of this Directive?
The directive comes from: The European Ecodesign Directive (2009/125/EC)
Overall, the aim of the directive is Energy Saving. It ensures more efficient electric radiators with following benefits;
“The aim of this legislation is to rule out inefficient technologies and reduce the energy used by the products that heat our homes, helping to achieve our national carbon reduction targets.” The Regulation will affect; Storage heaters Direct acting heaters Portable heaters Radiant heaters Electric fires
How does this change impact products? To comply with the Lot 20 Regulations, all local space heaters have to meet a minimum efficiency rating that is measured as a percentage. Electric radiators, infrared heaters and panel heaters are all classed as ‘fixed electric local space heaters’, and they must have at least a 38% efficiency rating if they have a nominal heat output above 250W.
As a result of these efficiency targets, products must include energy saving features such as better controls for end users.
Cost Savings to the end user as the radiator will perform more efficiently in the home arbon Emission Reduction helping protect our environment for C the future Improved customisation and control for end users as a result of more interactive and programmable capabilities in the products to help reduce unnecessary energy wastage
What about Zehnder electric products? As part of the changes, new features that offer benefit to end user to maximise efficiency and control will be included; ow energy consumption when on stand-by L Programmable operation (weekly) Open window detection Presence Detection Electric heating control details are included on each product page.
Zehnder Radio Frequency Control As part of the Eco Design Directive improvements, a Radio Frequency control is now available with a number of products offering; ireless control of radiator to end user - range of up to 30 W metres in open space and up to 10 metres between rooms (one wall) choice of pre-set programmes - working from a set A 'comfort temperature' by the end user
Showing wireless radio frequency pad for simple control and programming by end user.
4
ull customisation of weekly programme e.g. choose comfort F temperature and time during the day to work between eco and comfort settings.
PBECZ-120-50/F CHROME 0008
January 2019
5
AURA
TOWEL RAIL Central Heating Model STOCK listed in black
Height mm
Width mm
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Max. Immersion rating Watts*
RRP (ex VAT)
287/979 358/1221 418/1426 512/1747 598/2040 631/2153 740/2525 788/2689 925/3156 287/979 358/1221 418/1426 427/1457 512/1747 598/2040 788/2689 925/3156 151/515 186/635 230/785 271/925 287/979 278/949 330/1126 390/1331 346/1181 407/1389 481/1641 432/1473 513/1750 607/2071 741/2527
200 200 300 300 400 400 500/400 500/400 600 200 200 300 300 300 400 500/400 600 100/n/a 100/n/a 150/120 150/120 200 200 200 300 300 300 300 300 300 400 500
£90 £96 £101 £114 £119 £134 £138 £145 £153 £113 £120 £126 £136 £143 £149 £181 £191 £89 £108 £112 £118 £126 £135 £138 £141 £161 £167 £174 £178 £184 £190 £200
Zehnder Aura 22mm tube
NEW NEW NEW NEW NEW NEW NEW NEW
PBZ-080-040 775 400 PBZ-080-050 775 500 PBZ-080-060 775 600 PBZ-120-050 1217 500 PBZ-120-060 1217 600 PBZ-150-050 1469 500 PBZ-150-060 1469 600 PBZ-180-050 1856 500 PBZ-180-060 1856 600 PBZ-080-040-0346 775 400 PBZ-080-050-0346 775 500 PBZ-080-060-0346 775 600 PBZ-120-040-0346 1217 400 PBZ-120-050-0346 1217 500 PBZ-120-060-0346 1217 600 PBZ-180-050-0346 1856 500 PBZ-180-060-0346 1856 600 PBCZ-060-040 607 400 PBCZ-080-040 775 400 PBCZ-080-050 775 500 PBCZ-080-060 775 600 PBCZ-100-050 1027 500 PBCZ-120-040 1217 400 PBCZ-120-050 1217 500 PBCZ-120-060 1217 600 PBCZ-150-040 1469 400 PBCZ-150-050 1469 500 PBCZ-150-060 1469 600 PBCZ-180-040 1856 400 PBCZ-180-050 1856 500 PBCZ-180-060 1856 600 PBCZ-180-075 1856 750 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW
white white white white white white white white white Anthracite Anthracite Anthracite Anthracite Anthracite Anthracite Anthracite Anthracite chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome
2 5 10 Zehnder Aura 2
DAY
3-5
5
DAY
5-7
10
DAY
14
DAY WEEKS
17 3-5
A classic ladder-style towel warmer in sizes to suit all popular heating sizes and types of décor. Easily connected to an existing central heating system, or fitted with a dual energy electric element for summer use. (See page 48 for details). DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details Optional wall brackets
60
110-120
Model 926511 926518
Set of 4 replacement brackets in white for PBZ models Set of 4 replacement brackets in chrome for PBCZ models
W-44
RRP (ex VAT) £27 £27
* air vent Width excludes air vent F = flow R = return Tube: Horizontal \ 22mm Tube: Vertical D Profile 30 x 40mm All dimensions in mm
W-44
Suitable for dual energy installations. See page 48 for details.
PBZ-080 PBCZ-080
The complete 6
PBZ-120 PBCZ-120
PBZ-150 PBCZ-150
compliant technical specifications can be found between pages 49-57.
PBZ-180 PBCZ-180
Zehnder recommends VAL-SET-1-CR. For more information see page 48. PBCZ-150-050-0346 ANTHRACITE 0346
January 2019
7
AURA ELECTRIC Electric Heating Model
TOWEL RAIL Height mm
Width mm
Finish
Simple electric immersion heater Class II IPX4, Zones 1 and 2
RRP (ex VAT)
821 941 1261 1261 1901
400 500 500 600 500
chrome chrome chrome chrome chrome
150 200 300 400 500
£234 £239 £281 £285 £350
Zehnder Aura Electric 22mm tube PBECZ-080-40/F PBECZ-090-50/F PBECZ-120-50/F PBECZ-120-60/F PBECZ-180-50/F
Zehnder 2 5 10 Aura Electric DAY
3-5
Electric Heating Model
Height mm
Width mm
Finish
Adjustable thermostatic controller Class II IPX4 with 7 day programmer
RRP (ex VAT)
5
DAY
14
10
17 3-5
A classic yet stylish chrome electric towel radiator which is perfect for modern homes. Choose from a factory-fitted simple immersion heater or an adjustable thermostatic controller. WEEKS
3-5
DAY WEEKS
3-5 4-6
DAY DAY
5-7 20
DAY
14
DAY WEEKS
17 3-5
1287 1287
500 600
chrome chrome
300 400
£327 £330
Height measurements of electric models include electric heaters Optional wall brackets Model 926588
DAY
5-7
DAY WEEKS
Zehnder Aura Electric 22mm tube PBECZ-120-50/WF PBECZ-120-60/WF
2
Set of 4 replacement brackets in chrome for PBECZ models
RRP (ex VAT) £27
WEEKS
3-5
WEEKS
4-6
DAY
20
Tube: Horizontal \ 22mm Tube: Vertical D Profile 30 x 40mm All dimensions in mm
Simple Immersion heater
Adjustable thermostatic controller. Eco Design compliant with only the adjustable thermostatic controller 8
PBECZ-120-50/F CHROME 0008
January 2019
9
AURA BOW
TOWEL RAIL
Central Heating Model STOCK listed in black
Height mm
Width mm
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Max. Immersion rating Watts*
RRP (ex VAT)
494 595 494 595 494 595 494 595 494 595 494 595
white white white white white white chrome chrome chrome chrome chrome chrome
358/1221 418/1426 512/1747 598/2040 788/2689 925/3156 230/785 271/925 330/1126 390/1331 513/1750 607/2071
200 300 300 400 500/400 600 150/120 150/120 200 300 300 400
£101 £104 £123 £126 £156 £163 £115 £120 £141 £145 £193 £200
Zehnder Aura Bow 22mm tube PBTZ-080-050 775 PBTZ-080-060 775 PBTZ-120-050 1217 PBTZ-120-060 1217 PBTZ-180-050 1856 PBTZ-180-060 1856 PBTCZ-080-050 775 PBTCZ-080-060 775 PBTCZ-120-050 1217 PBTCZ-120-060 1217 PBTCZ-180-050 1856 PBTCZ-180-060 1856 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW
5
DAY
5-7
10
DAY
14
DAY WEEKS
17 3-5
A stylish, modern curved ladder radiator for warming towels. Suitable for connection to an existing central heating system or fitted with a dual energy electric element for summer usage. (See page 48 for details). DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
WEEKS
WEEKS
4-6
DAY
20
55-65
60
55-65
DAY
3-5
* air vent Width excludes air vent F = flow R = return Tube: Horizontal \ 22mm Tube: Vertical D Profile 30 x 40mm All dimensions in mm
60
110-120
W
W
2
3-5
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details
W
Zehnder 5 10 Aura 2Bow
W W-44
W-44
PBTZ-080 PBTCZ-080
PBTZ-080 PBTZ-120 PBTCZ-080 PBTCZ-120
PBZ-080 PBCZ-080
The complete 10
PBTZ-120 PBTZ-150 PBTCZ-120 PBTCZ-150
PBTZ-150 PBTZ-180 PBTCZ-150 PBTCZ-180
PBZ-120 PBCZ-120
compliant technical specifications can be found between pages 49 and 57.
PBZ-150 PBCZ-150
PBTZ-180 PBTCZ-180
Suitable for dual energy installations. See page 48 for details.
PBZ-180 PBCZ-180
Zehnder recommends VAL-SET-1-CR. For more information see page 48. PBTCZ-080-060 CHROME 0008
January 2019
11
KLARO Central Heating Model STOCK listed in black
TOWEL RAIL Height mm
Width mm
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Max. Immersion rating Watts*
RRP (ex VAT)
Zehnder Klaro ZSL-080-045-0336 ZSL-120-050-0336 ZSL-120-060-0336 ZSL-150-050-0336 ZSL-150-060-0336 ZSL-170-050-0336 ZSL-170-060-0336 ZSL-080-045-0523 ZSL-120-050-0523 ZSL-120-060-0523 ZSL-150-050-0523 ZSL-150-060-0523 ZSL-170-050-0523 ZSL-170-060-0523 ZSL-080-045-0529
748 1148 1148 1466 1466 1708 1708 748 1148 1148 1466 1466 1708 1708 748
450 500 600 500 600 500 600 450 500 600 500 600 500 600 450
volcanic volcanic volcanic volcanic volcanic volcanic volcanic beige quartz beige quartz beige quartz beige quartz beige quartz beige quartz beige quartz brown quartz
354/1208 571/1948 670/2286 716/2443 839/2863 824/2811 966/3296 354/1208 571/1948 670/2286 716/2443 839/2863 824/2811 966/3296 354/1208
200 400 500/400 500/400 500/400 500/400 600 200 400 500/400 500/400 500/400 500/400 600 200
£155 £188 £203 £233 £245 £261 £268 £155 £188 £203 £233 £245 £261 £268 £155
ZSL-120-050-0529
1148
500
brown quartz
571/1948
400
£188
ZSL-120-060-0529 1148 600 brown quartz 670/2286 500/400 ZSL-150-050-0529 1466 500 brown quartz 716/2443 500/400 ZSL-150-060-0529 1466 600 brown quartz 839/2863 500/400 ZSL-170-050-0529 1708 500 brown quartz 824/2811 500/400 ZSL-170-060-0529 1708 600 brown quartz 966/3296 600 An immersion heater for dual energy use can only be fitted in the header tube without the insert tube. Max. working pressure: 11.5 bar *Rating for simple immersion/CTEC or CTEW
£203 £233 £245 £261 £268
2 5 10 Zehnder Klaro 2
DAY
3-5
5
DAY
5-7
10
DAY
14
DAY WEEKS
17 3-5
A popular towel drying ladder rail available from stock in three contemporary colours, giving approximately 30% more output than chrome plus greater originality in bathroom design. It can be fitted with an immersion heater for use when the central heating system is not in use. (See page 48 for details). DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 16 working days.
94
94
*1/2” air vent Air vent can be moved either side depending on flow position. Width excludes air vent F = flow R = return Tube: Horizontal \ 23mm Tube: Vertical \ 38mm All dimensions in mm
ZSL-120
ZSL-150
ZSL-170
ZSL-080
The complete 12
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-1-CR. For more information see page 48.
ZSL-120-050-0336 VOLCANIC 0336
January 2019
13
MURALIS
TOWEL RAIL
Central Heating Model STOCK listed in black
Height mm
Width mm
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Finish
Max. Immersion rating Watts*
RRP (ex VAT)
200 200 300 300 400 150/120 200 200 200 300
£200 £233 £262 £288 £318 £209 £237 £285 £332 £381
Zehnder Muralis MUR-080-050-0346 800 500 anthracite MUR-100-050-0346 1000 500 anthracite MUR-120-050-0346 1200 500 anthracite MUR-140-050-0346 1400 500 anthracite MUR-160-050-0346 1600 500 anthracite MURC-080-050 800 500 chrome MURC-100-050 1000 500 chrome MURC-120-050 1200 500 chrome MURC-140-050 1400 500 chrome MURC-160-050 1600 500 chrome * Rating for simple immersion/CTEC or CTEW Max. working pressure: 4 bar
306/1044 384/1310 461/1573 537/1832 612/2088 197/672 249/850 301/1027 346/1181 391/1334
5
DAY
5-7
10
DAY
14
DAY WEEKS
17 3-5
A modern, attractive, towel radiator with evenly spaced square tubes, the Zehnder Muralis is suitable for fitting with a dual energy electric immersion heater for use when the central heating system is not operating. (See page 48 for details). DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
WEEKS
3-5
WEEKS
4-6
DAY
20
* air vent Width excludes air vent F = flow R = return Tube: Horizontal 23 x 23mm Tube: Vertical 30 x 30mm All dimensions in mm
H
H
H
H H
DAY
3-5
DAY WEEKS
H H
2
10
17 3-5
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details
H
Zehnder 2 5 Muralis
H
H
H
H MUR-100 MUR-100 MURC-100 MURC-100
MUR-120 MUR-120 MURC-120 MURC-120
MUR-100 MUR-100 MURC-100 MURC-100
MUR-080 MUR-080 MURC-080 MURC-080
MUR-120 MUR-120 MURC-120 MURC-120
MUR-080 MUR-080 MURC-080 MURC-080 H H
H
H H
H
H
H
MURC-100-050 CHROME 0008 MUR-140 MUR-140 MURC-140 MURC-140
MUR-140 MUR-140 MURC-140 MURC-140
The complete 14
compliant technical specifications can be found between pages 49 and 57.
MUR-160 MUR-160 MURC-160 MURC-160
MUR-160 MUR-160 MURC-160 MURC-160
Zehnder recommends VAL-SET-1-CR. For more information see page 48. MUR-100-050-0346 ANTHRACITE 0346
January 2019
15
STELLAR
STAINLESS STEEL Height mm
Width mm
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Max. Immersion rating Watts*
DAY
100/n/a 200 100/n/a 150/120 150/120 150/120 150/120 200 300 300 300 400 150 300 150 200
£244 £438 £245 £294 £345 £349 £399 £465 £616 £707 £711 £814 £244 £438 £245 £294
STNI-080-060-CF
788
600
s/steel painted
395/1348
200
£345
s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted
353/1204 482/1645 600/2047 591/2016 736/2511 672/2293 838/2859
200 300 400 400 500 500 600
£349 £399 £465 £616 £707 £711 £814
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details
5
DAY
3-5
DAY WEEKS
DAY WEEKS
4-6 14
DAY
20
DAY WEEKS
Simple, elegant and contemporary, the stainless steel Zehnder Stellar is the ideal solution for minimalist bathroom designs and wet rooms. DAY
DAY WEEKS
3-5
5-7 3-5
DAY WEEKS
144-6
DAY
20
DAY WEEKS
17 3-5
WEEKS
WEEKS
3-5
EE
4-6
DAY
20
L • S TA I N L E S
10
Year
Warranty
STNI-120-045 STAINLESS STEEL FINISH
*1/2” air vent Height excludes air vent F = flow R = return H = height W = width Tube: Horizontal \ 23mm Tube: Vertical 30x30mm All dimensions in mm
Width-30
10
3-55-7
DAY WEEKS
21 3-5
17 3-5
•
STNI-120-030-CF 1220 300 STNI-120-045-CFWidth-30 1220 450 STNI-120-060-CFWidth-30 1220 600 STNI-150-045-CF 1508 450 STNI-150-060-CF 1508 600 STNI-170-045-CF 1724 450 STNI-170-060-CF 1724 600 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW
2
INLESS S T S TA
159/541 284/970 159/541 206/702 253/863 242/826 316/1078 391/1334 389/1327 491/1675 452/1542 545/1860 233/795 430/1467 232/792 317/1082
STEEL
s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel painted s/steel painted s/steel painted s/steel painted
LESS
450 1000 300 450 600 300 450 600 450 600 450 600 450 1000 300 450
DAY
14
T E E L • S TA
572 572 788 788 788 1220 1220 1220 1508 1508 1724 1724 572 572 788 788
DAY
5-7
SS
STNI-060-045 STNI-060-100 STNI-080-030 STNI-080-045 STNI-080-060 STNI-120-030 STNI-120-045 STNI-120-060 STNI-150-045 STNI-150-060 STNI-170-045 STNI-170-060 STNI-060-045-CF STNI-060-100-CF STNI-080-030-CF STNI-080-045-CF
10
5
2 5 10 Zehnder Stellar 3-5
Zehnder Stellar
No price surcharge for colour finishes. Applies to all products in grey
2
RRP (ex VAT)
IN
Central Heating Model STOCK listed in black
STNI-080-030 STAINLESS STEEL FINISH
Width-30
Suitable for dual energy installations. See page 48 for details
Width-30
Colour finish: Standard colours from the Zehnder Colour Chart at no extra cost. Delivery of colour finish and non-stock products: 4-6 weeks. The complete 16
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-1-CR. For more information see page 48. STNI-060-100 STAINLESS STEEL FINISH
January 2019
17
STELLAR SPA
STAINLESS STEEL RRP (ex VAT)
161/549 272/928 171/583 220/751 243/829 240/819 309/1054 379/1293 361/1232 448/1529 434/1481 517/1764 219/747 394/1344 218/744 294/1003 363/1239 332/1133 448/1529 554/1890 556/1897 687/2344 640/2184 791/2699
100 150/120 100 100 150/120 150/120 150/120 200 300 300 200 300 150 200 150 200 200 200 300 300 300 400 400 500
£226 £406 £227 £272 £319 £323 £370 £431 £570 £655 £658 £754 £226 £406 £227 £272 £319 £323 £370 £431 £570 £655 £658 £754
Zehnder Stellar Spa s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted
DAY
3-5
2
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details
5
DAY
3-5
10
DAY WEEKS
3-5 5-7
10
5
10
DAY
5-7
DAY
14
DAY WEEKS
21 3-5 DAY WEEKS
4-6 14
DAY
20
DAY WEEKS
17 3-5
Contemporary in design in stainless steel to suit the latest lifestyle trends. Suitable for dual energy installation for year-long comfort. DAY
DAY WEEKS
3-5
5-7 3-5
DAY WEEKS
144-6
DAY
20
DAY WEEKS
17 3-5
WEEKS
WEEKS
3-5
EE
4-6
DAY
20
L • S TA I N L E S
10
Year
Warranty •
No price surcharge for colour finishes. Applies to all products in grey
STGI-060-045 572 450 STGI-060-100 572 1000 STGI-080-030 788 300 STGI-080-045 788 450 STGI-080-060 788 600 STGI-120-030 1220 300 STGI-120-045 1220 450 STGI-120-060 1220 600 STGI-150-045 1508 450 STGI-150-060 1508 600 STGI-170-045 1724 450 STGI-170-060 1724 600 STGI-060-045-CF 572 450 STGI-060-100-CF 572 1000 STGI-080-030-CF 788 300 STGI-080-045-CF 788 450 STGI-080-060-CF 788 600 STGI-120-030-CF 1220 300 STGI-120-045-CF 1220 450 STGI-120-060-CF 1220 600 STGI-150-045-CF 1508 450 STGI-150-060-CF 1508 600 STGI-170-045-CF 1724 450 STGI-170-060-CF 1724 600 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW
Zehnder 2 2 5 Stellar Spa
T E E L • S TA
Max. Immersion rating Watts*
SS
Output ∆T=50K Watts/Btu All outputs certified to EN 442
INLESS S T S TA
Finish
STEEL
Width mm
LESS
Height mm
IN
Central Heating Model STOCK listed in black
*1/2” air vent Height excludes air vent F = flow R = return H = height W = width Tube: Horizontal \ 23mm Tube: Vertical 30x30mm All dimensions in mm
STGI 080-030 STAINLESS STEEL FINISH
Suitable for dual energy installations. See page 48 for details
STGI-170-045 STAINLESS STEEL FINISH
Colour finish: Standard colours from the Zehnder Colour Chart at no extra cost. Delivery of colour finish and non-stock products: 4-6 weeks. The complete 18
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-1-CR. For more information see page 48.
STGI-060-100 STAINLESS STEEL FINISH
January 2019
19
TOWEL RAIL
ZETA Central Heating Model STOCK listed in black
Height mm
Width mm
Pipe centres mm
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Max. Immersion rating Watts
RRP (ex VAT)
324/1105 476/1624 647/2208 342/1105 476/1624 647/2208 203/689 235/792 302/1034 350/1204 395/1344 457/1559
200 300 400 200 300 400 200 200 300 400 400 400
£148 £193 £270 £185 £243 £339 £201 £239 £270 £317 £375 £442
Zehnder Zeta PQ6-080-050 800 PQ6-120-050 1200 PQ6-160-050 1600 PQ6-080-050-0346 800 PQ6-120-050-0346 1200 PQ6-160-050-0346 1600 PQ6C-080-050 800 PQ6C-080-060 800 PQ6C-120-050 1200 PQ6C-120-060 1200 PQ6C-160-050 1600 PQ6C-160-060 1600 Max. working pressure: 4 bar
500 500 500 500 500 500 500 600 500 600 500 600
468 468 468 468 468 468 468 568 468 568 468 568
white white white anthracite anthracite anthracite chrome chrome chrome chrome chrome chrome
Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details
2 5 10 Zehnder Zeta 2
DAY
3-5
5
DAY
5-7
10
DAY
14
DAY WEEKS
17 3-5
A popular variation of steel ladder rail suitable for installation on an existing central heating system. It is ideally suited for fitting with a dual energy electric immersion heater for use when the central heating is not in operation. (See page 48 for details). DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
* air vent Width excludes air vent F = flow R = return Tube: Horizontal oval tube 60 x 10mm Tube: Vertical \ 32mm All dimensions in mm
W W-32
W
W
H
H
900
H
CHROME 0008
PQ6-080 PQ6C-080
PQ6-120 PQ6C-120 PQ6-160 PQ6C-160
TRAFFIC WHITE 9016
The complete 20
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-1-CR. For more information see page 48. PQ6-120-050-0346 ANTHRACITE 0346
January 2019
21
CHARLESTON
MULTI-COLUMN
Central Heating Model STOCK listed in black
Height mm
Width mm
Overall Projection
Output ∆T=50K Watts/Btu All outputs certified to EN 442
No. of sections
RRP (ex VAT)
Zehnder Charleston Horizontal white RAL 9016 - 2 column 2050-10 2050-14 2050-18 2050-22 2050-26 2060-10 2060-14 2060-18 2060-22 2060-24 2060-28
492 492 492 492 492 592 592 592 592 592 592
486 670 854 1038 1222 486 670 854 1038 1130 1314
90 90 90 90 90 90 90 90 90 90 90
10 14 18 22 26 10 14 18 22 24 28
384/1310 538/1836 691/2358 845/2883 998/3405 453/1546 634/2163 815/2781 997/3402 1080/3685 1260/4284
£168 £235 £303 £370 £437 £174 £243 £313 £382 £417 £487
14 18 22 26 30 10 14 18 20 24 27 30 34 14 22 26
722/2463 929/3170 1135/3873 1342/4579 1548/5282 609/2078 853/2910 1096/3740 1220/4163 1464/4995 1645/5613 1827/6234 2071/7066 1040/3548 1635/5579 1932/6592
£279 £359 £439 £519 £599 £211 £295 £379 £421 £505 £569 £632 £716 £331 £520 £614
20 30 14 18 20 24 14 18 22 26
840/2866 1260/4299 1117/3811 1436/4900 1592/5459 1920/6551 1364/4654 1753/5981 2143/7312 2532/8639
£423 £635 £310 £399 £443 £532 £374 £481 £588 £695
500 670 500 854 500 1038 500 1222 500 1406 600 486 600 670 600 854 600 946 600 1130 600 1268 600 1406 2 Column 2 Column 600 1590 750 670 750 1038 750 1222
128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128
3-6 Column
2 Column
3-6 Column
3050-14 3050-18 3050-22 3050-26 3050-30 3060-10 3060-14 3060-18 3060-20 3060-24 3060-27 3060-30 3060-34 3075-14 3075-22 3075-26
2 Column
Zehnder Charleston Horizontal white RAL 9016 - 3 column
Zehnder 2 5 10 2 5 10 Charleston DAY
DAY
3-5
DAY
5-7
2
DAY
3-5
WEEKS
3-5
5
14 DAY
5-7
WEEKS
4-6
10
DAY DAY WEEKS
3-5 15 14
DAY DAY WEEKS
20 3-5 17
The Zehnder Charleston multicolumn design is equally at home in modern environments, and is available in a wide range of stocked horizontal and vertical models, or made-tomeasure, including angled and curved. Find out more about LaZer made on page 60. DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
Zehnder Charleston Horizontal white RAL 9016 - 4 column 4030-20 4030-30 4060-14 4060-18 4060-20 4060-24 4075-14 4075-18 4075-22 4075-26
300 300 600 600 600 600 750 750 750 750
946 1406 670 854 946 1130 670 854 1038 1222
164 164 164 164 164 164 164 164 164 164
2 Column
486 670 854 946 1130 1268 1406 1590
3-6 Column
2 Column
600 600 600 600 600 600 600 600
3-6 Column
Zehnder Charleston Horizontal - 3 column 3 Column 3anthracite Column 4 Column 4 Column 3060-10-0346 3060-14-0346 3060-18-0346 3060-20-0346 3060-24-0346 3060-27-0346 3060-30-0346 3060-34-0346
128 128 128 128 128 128 128 128
5 Column 5 Column
Technoline 0325. For more information please see page 58.
6 Column 6 Column
10 14 18 20 24 27 30 34
£243 £339 £436 £484 £581 £654 £727 £823
609/2078 853/2910 1096/3740 1220/4163 1464/4995 1645/5613 1827/6234 2071/7066
Black-silver hammered 0422
Model code breakdown: eg. 3060-34 = 3 (number of columns), 060 (600mm high), 34 (number of sections). 2 Column2 Column
Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks.
3 Column3 Column 2 Column
The complete
4 Column4 Column
5 Column5 Column
compliant technical specifications can be found between pages 49 and 57. 3 Column 3 Column
22
*1/2” air vent Width excludes air vent F = flow R = return H = height W = width Tube: Vertical \ 25mm All dimensions in mm Manufacturing tolerance of +/-0.6mm per section
3-6 Column
2 Column
Expect manufacturers marks on Charleston finishes. See page 60 for more information.
Adjustable Foot
6 Column6 Column
Don’t forget to use your Charleston radiator packaging to protect your new radiator whilst decorating - see the cardboard outer for details.
Cast Iron Foot
2050-18 TRAFFIC WHITE 9016
January 2019
23
CHARLESTON Central Heating Model STOCK listed in black
MULTI-COLUMN
Height mm
Width mm
Number of sections
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
RRP (ex VAT)
Zehnder Charleston vertical 2180-6 1792 302 6 white 2180-8 1792 394 8 white 2180-10 1792 486 10 white 2180-12 1792 578 12 white 3180-6 1800 302 6 white 3180-8 1800 394 8 white 3180-10 1800 486 10 white 2180-8-0346 1792 394 8 anthracite 2180-10-0346 1792 486 10 anthracite 2180-12-0346 1792 578 12 anthracite Model code breakdown: eg. 3180-8 - 3 (number of columns), 180 (180cm high) 8 (number of sections).
744/2539 992/3385 1240/4231 1488/5077 996/3398 1328/4531 1660/5664 992/3385 1240/4231 1488/5077
£249 £332 £414 £497 £341 £455 £568 £382 £476 £572
Zehnder 2 5 10 2 5 10 Charleston DAY
DAY
3-5
2
DAY
3-5
WEEKS
3-5
4 Column 4 Column
5
14
DAY
5-7
WEEKS
4-6
10
DAY DAY WEEKS
3-5 15 14
DAY DAY WEEKS
20 3-5 17
A timeless decorative radiator that suits modern or traditional settings, the multicolumn is available from stock in a RAL 9016 white finish and stylish Anthracite textured finish, or to order from a range of 50 other colours. Wall supports and air vents are included. Stylish support feet are available if required. Find out more about LaZer made on page 60. DAYWEEKS
3-53-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
WEEKS
3 Column 3 Column
DAY
5-7
5 Column 5 Column
6 Column 6 Column
*1/2” air vent Width excludes air vent F = flow R = return H = height W = width Tube: Vertical \ 25mm All dimensions in mm Manufacturing tolerance of +/-0.6mm per section
3 Column 3 Column
3-5
WEEKS
4-6
DAY
20
HORIZON BLUE 0520
You can use our Charleston packaging to protect your radiator whilst decorating. Instructions on the pack. Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The complete 24
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-2-CR. For more information see page 48. ANTHRACITE 0346
January 2019
25
CHARLESTON MADE TO MEASURE Nominal Model Output 50∆T Height code Watts/BTU mm
M2M MULTI-COLUMN
RRP white (ex VAT)
RRP colour (ex VAT)
Model Output 50∆T code Watts/BTU
RRP white (ex VAT)
RRP colour (ex VAT)
3 column
Zehnder Charleston - 2 column
Model Output 50∆T code Watts/BTU
RRP white (ex VAT)
RRP colour (ex VAT)
4 column
200
2019
14.5/49
£16.60
£20.75
3019
20.1/69
£19.67
£24.59
4019
28.4/97
£21.11
£26.39
260
2026
21.1/72
£16.62
£20.78
3026
27/92
£19.70
£24.63
4026
36.5/125
£21.14
£26.43
300
2030
24/81
£16.66
£20.83
3030
32/109
£19.72
£24.65
4030
42/143
£21.16
£26.45
342
2035
27.5/94
£16.68
£20.85
3035
37/126
£19.77
£24.71
4035
48.5/165
£21.55
£26.94
400
2040
31/106
£16.71
£20.89
3040
42/143
£19.82
£24.78
4040
55/187
£21.94
£27.43
450
2045
35/119
£16.76
£20.95
3045
47/160
£19.90
£24.88
4045
61/209
£22.00
£27.50
500
2050
38/131
£16.82
£21.03
3050
52/176
£19.95
£24.94
4050
68/232
£22.06
£27.58
550
2055
42/143
£17.33
£21.66
3055
56/192
£21.01
£26.26
4055
74/251
£22.12
£27.65
600
2060
45/155
£17.38
£21.73
3060
61/208
£21.06
£26.33
4060
80/272
£22.17
£27.71
750
2075
55/188
£20.17
£25.21
3075
74/254
£23.62
£29.53
4075
97/332
£26.74
£33.43
900
2090
64/218
£23.29
£29.11
3090
87/297
£27.85
£34.81
4090
114/389
£32.30
£40.38
1000
2100
70/239
£25.63
£32.04
3100
95/324
£30.08
£37.60
4100
125/427
£35.65
£44.56
1200
2120
83/282
£31.87
£39.84
3120
115/392
£40.10
£50.13
4120
147/502
£50.13
£62.66
1500
2150
104/355
£37.54
£46.93
3150
140/478
£49.02
£61.28
4150
180/614
£63.50
£79.38
1800
2180
124/423
£41.44
£51.80
3180
166/566
£56.82
£71.03
4180
213/727
£71.30
£89.13
2000
2200
138/471
£45.68
£57.10
3200
183/624
£64.62
£80.78
4200
234/798
£79.10
£98.88
RRP white (ex VAT)
RRP colour (ex VAT)
RRP white (ex VAT)
RRP colour (ex VAT)
Nominal Model Output 50∆T Height code Watts/BTU mm
Model Output 50∆T code Watts/BTU 6 column
Zehnder Charleston - 5 column 300
5030
52/177
£27.85
£34.81
6030
61/209
£34.64
£43.30
400
5040
68/232
£28.96
£36.20
6040
81/275
£36.32
£45.40
450
5045
76/259
£30.08
£37.60
6045
90/306
£37.21
£46.51
500
5050
84/285
£30.64
£38.30
6050
99/338
£38.11
£47.64
550
5055
91/310
£31.87
£39.84
6055
108/369
£39.22
£49.03
600
5060
99/336
£32.98
£41.23
6060
117/399
£40.33
£50.41
750
5075
120/409
£34.09
£42.61
6075
143/488
£42.00
£52.50
900
5090
141/481
£38.66
£48.33
6090
167/570
£48.91
£61.14
1000
5100
154/525
£44.34
£55.43
6100
183/624
£55.70
£69.63
1200
5120
179/611
£57.93
£72.41
6120
210/717
£72.75
£90.94
1500
5150
219/747
£77.31
£96.64
6150
256/873
£90.91
£113.64
Max. working pressure: 10 bar
All data and prices per 46mm section
Zehnder 2 5 10 Charleston DAY
3-5
DAY
2 WEEKS
3-5
DAY
5-7
5
14
10 DAY WEEKS
3-5 15
WEEKS
4-6
DAY
20
The traditional column radiator for central heating, available as made-to-measure in horizontal, vertical, angled or curved forms, with 50 colours from which to choose. A range of welded-on feet are available if required. DAY
3-5
DAY
5-7
DAY
14
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
Dimensions: Nominal overall radiator length = (No. of sections x 46mm) + 26mm (Manufacturing tolerance of +/- 1.5% in length, +/- 2mm in height, +/- 5mm in depth).
Selection example: Output required: approximately 1000 watts Dimensions required: approximately 600mm H x 900mm L Formula: (No. of sections x 46mm) + 26mm Calculation of sections: 900mm - 26mm divided by 46 = 19 sections 1000w divided by 19 section = approximately 52 watts/section required Radiator selection: 3050 = 52 watts/section 52w x 19 section = 988 watts (50∆t) Price calculation: 19 sections x £19.95 = £379.05 plus VAT
CHARLESTON CURVED
Foot support options (wall brackets included as standard) Model
No of Feet RRP white (ex VAT) RRP colour (ex VAT)
Welded-on fixed - 150mm (WF150) or adjustable fixed - 120-170mm (WF120) feet with cover plate Price per radiator 8 - 20 sections
2
£65.50
£81.88
21 - 40 sections
3
£98.25
£122.81
41 - 60 sections
4
£131.00
£163.75
Technoline 0325. For more information please see page 58.
Welded-on traditional - 100mm (WF100) or 150mm (WFTF150) feet Price per radiator 2 - 20 sections
2 pairs
£89.00
£111.25
21 - 40 sections
3 pairs
£133.50
£166.88
41 - 60 sections
4 pairs
£178.00
£222.50
976131 white
1
£32.00
976139 colour
1
Adjustable foot (100-150mm).
Price per foot £40.00
Must always be used with wall brackets Cast iron foot (100mm high) ZPGG-9016
Price per foot 1
£22.00
EasyFix brackets The amount of pieces required depends on the height and width of the radiator. SMB-2PC SMB-3PC SMB-4PC SMB-5PC
£33.00 £50.00 £67.00 £83.00
£41.00 £63.00 £84.00 £104.00
Standard CVD brackets supplied with Charleston radiators - colour to match the radiator Note: Optional longer brackets available to order, to achieve longer distance from back of the radiator to the wall. CVD0 (supplied with the radiator) 28mm CVD1 43mm CVD2 63mm
EasyFix bracket for radiators 300mm to 1000mm in height
BLACK-SILVER HAMMERED 0422
EasyFix bracket for radiators below 260mm and above 1100mm in height
Prices for Easyfix Brackets are given as a guide – please contact us to determine which brackets you require depending on the size of your radiator. Due to manufacturing tolerances in this product we recommend that you do not pre-pipe. Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The complete 26
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-2-CR. For more information see page 48.
TRAFFIC WHITE 9016
January 2019
27
KLEO
TUBULAR COLUMN RADIATOR
Central Heating Model STOCK listed in black
Height mm
Width mm
Number of tubes
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
2
RRP (ex VAT)
5
2 5 10 Zehnder Kleo DAY
DAY
3-5
Zehnder Kleo vertical KLV-180-030 KLV-180-040 KLV-180-050 KLV-180-060 KLVC-180-030 KLVC-180-040 KLVC-180-050 KLVC-180-060
1800 1800 1800 1800 1800 1800 1800 1800
299 398 497 596 299 398 497 596
9 12 15 18 9 12 15 18
white white white white chrome chrome chrome chrome
632/2156 842/2874 1053/3593 1260/4320 448/1529 597/2040 747/2549 896/3057
£217 £265 £313 £361 £404 £493 £583 £672
KLH-058-100 596 KLH-058-120 596 KLH-058-140 596 KLHD-058-100 596 KLHD-058-120 596 KLHD-058-140 596 Max. working pressure: 11.5 bar
1000 1200 1400 1000 1200 1400
18 18 18 18 18 18
white white white white white white
782/2668 938/3201 1094/3735 1211/4134 1453/4961 1695/5787
£273 £299 £324 £478 £523 £568
10
5-7
DAY
14
DAY WEEKS
17 3-5
2
DAY
3-5
5
DAY
5-7
10
WEEKS DAY
3-5 14
WEEKS
4-6
DAY
20
DAY WEEKS
17 3-5
A contemporary tubular column radiator in vertical and horizontal orientations, supplied from stock in a RAL 9016 white finish or stylish, modern chrome. Brackets and an air vent included. DAY WEEKS
3-5 3-5
DAY WEEKS
5-7 4-6
DAY DAY
1420
DAY WEEKS
17 3-5
Zehnder Kleo horizontal
WEEKS
3-5
WEEKS
4-6
DAY
20
Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The KLV can also be installed horizontally with TBSE connections on either side
KLH KLHD KLHC
KLH KLHD KLHC
*1/8” air vent Width excludes air vent F = flow R = return Tube: Horizontal \ 38mm Tube: Vertical \ 20mm All dimensions in mm Max. working pressure: 4 bar
KLH KLHC
KLH KLHD KLHC
KLH KLHC
KLH KLHC
KLH KLHC
KLHD
KLV KLVC
KLV KLVC
KLH KLHD KLHC
KLHD
KLH KLHC
KLH KLHD KLHC
KLH KLHC
KLVC-180-060 TRAFFIC WHITE 9016
KLHD
Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The complete 28
compliant technical specifications can be found between pages 49 and 57. KLHD
KLHD
Zehnder recommends VAL-SET-2-CR. For more information see page 48. KLVC-180-040 CHROME 0008
January 2019
29
LYTA-S
HORIZONTAL ALUMINIUM
Central Heating Model STOCK listed in black
Height mm
Width mm
Number of sections
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
RRP (ex VAT)
546/1863 728/2484 910/3105 1092/3726 1274/4347 737/2516 983/3354 1229/4193 1475/5032 1721/5871 848/2895 1131/3860 1414/4824 1697/5789 1980/6754
£162 £216 £270 £324 £378 £168 £224 £280 £336 £392 £174 £232 £290 £348 £406
2 5 10 Zehnder Lyta-S
Zehnder Lyta-S LYSV-Z-040-048 LYSV-Z-040-064 LYSV-Z-040-080 LYSV-Z-040-096 LYSV-Z-040-112 LYSV-Z-055-048 LYSV-Z-055-064 LYSV-Z-055-080 LYSV-Z-055-096 LYSV-Z-055-112 LYSV-Z-065-048 LYSV-Z-065-064 LYSV-Z-065-080 LYSV-Z-065-096 LYSV-Z-065-112
395 395 395 395 395 545 545 545 545 545 645 645 645 645 645
480 640 800 960 1120 480 640 800 960 1120 480 640 800 960 1120
6 8 10 12 14 6 8 10 12 14 6 8 10 12 14
white white white white white white white white white white white white white white white
Max. working pressure: 16 bar When adding or removing sections; joining nipples, gaskets and an assembly tool should be additionally purchased as required for the installation. Please note, brackets for this order will be delivered in a separate box and will appear as a separate line listing on your delivery note.
Accessories RRP (ex VAT) £72 £51 £51 £51 £51 £2.60 £0.60 £1.30 £24 £23
Towel rail for 6 section Lyta-S. White RAL9010 (see below) Aluminium assembly tool 300 Aluminium assembly tool 600 Aluminium assembly tool 900 Aluminium assembly tool 1200 1 inch steel joining nipple -for use with Lyta-S Joining nipple gasket for joining the Lyta-S. White RAL 9010 Gasket for end plugs for Lyta-S - Green Installation bush and bracket pack for Lyta-S Service assembly kit for the Lyta-S radiator
Height-77
Model A36/6 905110 905120 905130 905140 A2/1 A10/1 A11/1 A81 A80
2
5
10
DAY
3-5
DAY
5-7
DAY
14
DAY WEEKS
17 3-5 DAY
3-5
A high output, low water content, die-cast aluminium radiator, giving a fast response, comfortable heat with high thermal energy efficiency. Easy to handle, the Lyta-S is resistant to corrosion with the ability to add or remove sections according to requirements. Brackets (separate box), plugs, bushes and air vent are included. DAY
5-7
DAY
14
WEEKS
3-5
WEEKS
4-6
DAY
20
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
By
*1/2” air vent Width excludes air vent F = flow R = return H = height W = width All dimensions in mm
Width+24
The complete 30
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-2-CR. For more information see page 48. LYSV-Z-065-064 PURE WHITE 9010
January 2019
31
LYTA-T
VERTICAL ALUMINIUM
Central Heating Model STOCK listed in black
Height mm
Width mm
Number of sections
Finish
Output ∆T=50K Watts/Btu All outputs certified to EN 442
RRP (ex VAT)
728/2484 1092/3726 1000/3412 1500/5118 900/3071 1200/4094 1500/5118 1800/6142
£232 £348 £328 £492 £291 £388 £485 £582
2 5 10 Zehnder Lyta-T
Zehnder Lyta-T LYTV-Z-097-032 LYTV-Z-097-048 LYTV-Z-147-032 LYTV-Z-147-048 LYTV-Z-187-024 LYTV-Z-187-032 LYTV-Z-187-040 LYTV-Z-187-048
966 966 1466 1466 1866 1866 1866 1866
320 480 320 480 240 320 400 480
4 6 4 6 3 4 5 6
white white white white white white white white
Max. working pressure: 16 bar When adding or removing sections; joining nipples, gaskets and an assembly tool should be additionally purchased as required for the installation. Please note, brackets for this order will be delivered in a separate box and will appear as a separate line listing on your delivery note.
Accessories Model 905110 905120 905130 905140 A32/1 A33/1 A82 A36/4 A36/5 A36/6
Aluminium assembly tool 300 Aluminium assembly tool 600 Aluminium assembly tool 900 Aluminium assembly tool 1200 Gasket for nipples, plugs and adaptors for Lyta-T - Black 1 inch steel joining nipple for Lyta-T Installation bush and bracket pack for Lyta-T Towel rail for 4 section Lyta-T. White (RAL9010) Towel rail for 5 section Lyta-T. White (RAL9010) Towel rail for 6 section Lyta-S and Lyta-T. White (RAL9010)
RRP (ex VAT) £51 £51 £51 £51 £1.30 £2.80 £24 £57 £66 £72
2
5
10
DAY
3-5
DAY
5-7
DAY
14
DAY WEEKS
17 3-5 DAY
3-5
The Lyta is a high output, low water content, extruded aluminium radiator. Resistant to corrosion, sections can be added or removed to suit installation requirements. The Lyta-T has the practical option of a towel bar. Brackets (separate box), plugs, bushes and air vent are included. DAY
5-7
DAY
14
WEEKS
3-5
WEEKS
4-6
DAY
20
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
By
*1/2” air vent Width excludes air vent F = flow R = return H = height W = width All dimensions in mm
The complete 32
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-2-CR. For more information see page 48.
LYTV-Z-187-040 PURE WHITE 9010
January 2019
33
RODA NEW
FLAT PANEL RADIATOR
Central Heating Model STOCK listed in black
Height mm
Width mm
Overall projection
Finish
Number of tubes
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Weight kg
RRP (ex VAT)
70 70 70 70 70 70
white white white white white white
4 5 6 7 8 9
568/1940 710/2425 852/2910 994/3395 1136/3880 1278/4365
12.0 15.0 18.0 21.0 24.0 27.0
£207 £242 £277 £312 £347 £382
93 93 93 93 93 93
white white white white white white
4 5 6 7 8 9
824/2812 1030/3515 1236/4218 1442/4921 1648/5624 1854/6327
22.4 28.0 33.6 39.2 44.8 50.4
£333 £396 £459 £522 £585 £648
Zehnder Roda Vertical Single panel ROV-180-029 ROV-180-037 ROV-180-044 ROV-180-051 ROV-180-059 ROV-180-066
1800 1800 1800 1800 1800 1800
296 370 444 518 592 666
Zehnder Roda Vertical Double panel ROVD-180-029 ROVD-180-037 ROVD-180-044 ROVD-180-051 ROVD-180-059 ROVD-180-066
1800 1800 1800 1800 1800 1800
Central Heating Model STOCK listed in black
Height mm
74
3-5
Width mm
Overall projection
Finish
Number of tubes
Output ∆T=50K Watts/Btu All outputs certified to EN 442
Weight kg
RRP (ex VAT)
70 70 ?? 70 70 70
white white white white white white
7 7 8 8 8 8
586/1999 703/2399 532/1815 150 665/2269 798/2723 931/3177
13.4 16.1 4.48 14.1 18.1 19.7
£208 £229 £211 £235 £259 £283
18 21.59 13.2 17.6 22.0 26.4 30.72 35.1
£315 £353 £259 £301 £344 £387 £429 £472
74
10
5 5 DAY
5-7
2
5
DAY
DAY
3-5
WEEKS
ROV & ROVD can be installed horizontally with TBSE connections either side.
ne vertical
DAY
3-5
296 370 444 518 592 666
Fassane horizontal Fassane horizontal
ertical
Zehnder 2 Roda 2
5-7
WEEKS
4-6
10 DAY
14
10 DAY DAY WEEKS
1714 3-5
DAY DAY
WEEKS 203-5 17
A perfect example of a simple & classic radiator, the Zehdner Roda is efficient enough for all living areas and adds a touch of style to any space. WEEKS DAY
3-5 3-5
WEEKS DAY
4-6 5-7
DAY DAY
20 14
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
7 7 8 8 8 8 8 8
100
F/R ROVD R/F
H
42
42
927/3163 1112/3794 W 636/2170 848/2894 1060/3617 1272/4340 1504/5132 34 1718/5862
W-68 ROH ROH W-68 34 ROHD ROH R ROHL F ROHD flow & return can be manufactured reversed on request ROHL R F white 8 636/2170 flow & return can be manufactured reversed on request
Fassane horizontal ertical Fassane horizontal vertical ertical ROV
Zehnder RodaROV Horizontal Double panel
ROH W
110
white white white white white white white 34 white H
200
70 70 92 92 92 92 70 70
34
ROH
34
H
W-49
1000 1200 600 800 1000 1200 1400 1600
100
518 518 592 592 592 592 592 24.5 592
H
ROHL-052-100 ROHL-052-120 ROHL-059-060 ROHL-059-080 ROHL-059-100 ROHL-059-120 ROHL-059-140 24.5 ROHL-059-160
150
ROH
Zehnder Roda Horizontal Single panel with single convector fin w
150
110
ROV
150
34
70
74
70
w
1000 1200 800 741000 1200 1400
70
ROV
42
518 518 592 592 592 592
42
70
ROH-052-100 ROH-052-120 ROH-059-080 ROH-059-100 ROH-059-120 ROH-059-140
200
Zehnder Roda Horizontal Single panel
ROHL-059-060
592
600
92
13.2
£307
ROHL-059-080
592
800
92
white
8
848/2894
17.6
£348
92 92
white white
8 8
1060/3617 1272/4340
22.0 26.4
£389 £430
ROHL-059-100 ROHL-059-120
24.5
W-49 592 ROV 592
F/R ROVD R/F
24.5
1000 1200
ROV
ROVD-180-029-TRAFFIC WHITE 9016
Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks.
ROH W
W
ROHL ROHL
F/R R/F flow & return be reversed W-49 24.5 24.5 24.524.5 can W-49 24.524.5 W-49 24.5 W-49 24.5 ROV ROV ROVD ROV ROV ROV ROVD ROVD R/F ROVR/FF/R F/RF/R R/F flow & return F/R ROVD R/F can be reversed
The complete 34
ROVD
34
ROHD
34
compliant technical specifications can be found between pages 49 and 57.
ROH ROHL
ROHD
34
W-68
ROHD 34 W-68 34 W-68 34 R F ROH ROHD ROHD FROHL R F W-68 34 flow34& return can be manufactured reversed on request ROH ROHD ROHL F R flow & return can be manufactured reversed on request
H
ROVD
100
ROVD
24.5 100 100 100
W-49
34 110
34
24.5
34
H
H
W
ROHL
R ROH
34
100
H
H HH
H
W ROHL ROH
150 ROHD
110
150
110
70
200
200 200 200
H
150
150
ROHD
w
w w w
150
*1/8” air vent Width excludes air vent F = flow R = return H = height W = width Tube dimensions 70mm x 11mm Vertical tubes: \ 38mm All dimensions in mm
110
150
70
150
66
200 ROVD
66
42 42 42
93
70 70 70
ROV ROV ROV
150
66
74
42
74 74 74
ROHL
42
w74
93
ROVD
93
74 74 74
74
66
93
74
X = Variation in radiator height. 2 - 4 tubes tall = 35mm 5 tubes tall = 109mm 6 tubes tall = 55mm 7 tubes tall = 129mm 8 tubes tall = 63mm
Zehnder recommends VAL-SET-2-CR. For more information see page 48.
ROH-059-080 TRAFFIC WHITE 9016
January 2019
35
RODA MADE TO MEASURE NEW
M2M FLAT PANEL
Zehnder Roda (ROV) vertical, single panel white Width
Height (mm)
(mm)
No of tubes
ROV-060 600
ROV-080 800
ROV-100 1000
ROV-120 1200
ROV-140 1400
ROV-160 1600
ROV-180 1800
ROV-200 2000
ROV-220 2200
296
4
£134
£144
£159
£169
£183
£197
£207
£221
£232
370
5
£154
£166
£184
£196
£213
£230
£242
£259
£272
444
6
£174
£188
£209
£223
£243
£263
£277
£297
£312
518
7
£194
£210
£234
£250
£273
£296
£312
£335
£352
592
8
£214
£232
£259
£277
£303
£329
£347
£373
£392
666
9
£234
£254
£284
£304
£333
£362
£382
£411
£432
740
10
£254
£276
£309
£331
£363
£395
£417
£449
£472
52/177
68/232
83/283
98/334
113/386
127/433
142/485
155/529
169/577
Technical data per tube
Zehnder 2 5 Roda DAY
3-5
2 WEEKS
3-5
Watts/BTU
Output calculation example 50∆t (watts):
3-5
Zehnder Roda (ROVD) vertical, double panel white Width
Height (mm) ROVD-060 ROVD-080 ROVD-100 ROVD-120 ROVD-140 ROVD-160 ROVD-180 ROVD-200 ROVD-220 600 800 1000 1200 1400 1600 1800 2000 2200
296
4
£200
£224
£246
£264
£287
£309
£333
£355
£377
370
5
£234
£263
£290
£312
£340
£367
£396
£423
£450
444
6
£268
£302
£334
£360
£393
£425
£459
£491
£523
518
7
£302
£341
£378
£408
£446
£483
£522
£559
£596
592
8
£336
£380
£422
£456
£499
£541
£585
£627
£669
666
9
£370
£419
£466
£504
£552
£599
£648
£695
£742
740
10
£404
£458
£510
£552
£605
£657
£711
£763
£815
77/263
100/341
122/416
144/491
165/563
186/635
206/703
225/768
244/833
Technical data per tube
Output 50∆T
(Watts/BTU)
Output calculation example 50∆t (watts):
5
10 DAY WEEKS
17 3-5
WEEKS
4-6
DAY
20
DAY
5-7
DAY
14
17 3-5
WEEKS
No of tubes
DAY
14
DAY WEEKS
1800H x 592W: 142 x 8 = 1136w
3-5
(mm)
DAY
5-7
Made-to-measure Zehnder Roda radiators are easy and quick to order. They are simple, effective and efficient decorative radiators, available as horizontal or vertical and are perfect for all living areas. DAY
Output 50∆T
10
WEEKS
4-6
DAY
20
1800H x 592W: 206 x 8 = 1648w
Zehnder Roda (ROH) horizontal, single panel white Height
Technical data per metre
Width (mm)
Model Code
(mm)
No of tubes
Output 50∆T Watts/BTU
600
800
1000
1200
1400
1600
1800
2000
2200
ROH-030
296
4
344/1174
£106
£118
£130
£142
£154
£167
£179
£191
£203
ROH-037
370
5
425/1450
£125
£140
£155
£170
£185
£200
£215
£230
£245
ROH-044
444
6
506/1726
£147
£165
£183
£201
£219
£238
£256
£274
£292
ROH-052
518
7
586/1999
£166
£187
£208
£229
£250
£271
£292
£313
£334
ROH-060
592
8
665/2269
£187
£211
£235
£259
£283
£307
£331
£355
£379
ROH-067
666
9
744/2537
£207
£234
£261
£288
£315
£342
£369
£396
£423
ROH-074
740
10
823/2806
£227
£257
£287
£317
£347
£377
£407
£437
£467
Output calculation example 50∆t (watts):
518H x 1200L: 586 x 1.2 = 667w
Zehnder Roda (ROHL) horizontal, single panel, single fin white Height
Technical data per metre
Width (mm)
Model Code
(mm)
No of tubes
Output 50∆T Watts/BTU
600
800
1000
1200
1400
1600
1800
2000
2200
ROHL-014
148
2
350/1194
£152
£171
£190
£209
£228
£246
£265
£284
£303
ROHL-022
222
3
511/1744
£157
£178
£198
£218
£239
£259
£280
£300
£320
ROHL-030
296
4
637/2173
£177
£202
£227
£252
£277
£301
£326
£351
£376
ROHL-037
370
5
719/2453
£198
£227
£256
£285
£314
£344
£373
£402
£431
ROHL-044
444
6
845/2883
£218
£251
£285
£319
£352
£386
£419
£453
£487
ROHL-052
518
7
927/3163
£239
£277
£315
£353
£391
£430
£468
£506
£544
ROHL-060
592
8
1060/3617
£259
£301
£344
£387
£429
£472
£514
£557
£600
ROHL-067
666
9
1157/3945
£279
£326
£373
£420
£467
£514
£561
£608
£655
ROHL-074
740
10
1237/4218
£300
£351
£403
£455
£506
£558
£609
£661
£713
Output calculation example 50∆t (watts):
Made-to-measure
518H x 1200L: 927 x 1.2 =1112w
Details on intermediate sizes are available on request (1-20 tubes) Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. All prices exclude VAT The complete 36
compliant technical specifications can be found between pages 49 and 57.
Zehnder recommends VAL-SET-2-CR. For more information see page 48.
ROV-160-5 PERGAMON 0081
January 2019
37
STANA
LOW LOVEL CONVECTOR
Central Heating
Height mm
Width mm
Depth mm
Finish
Output ∆T=50 Watts/btu All outputs certified to EN 442
RRP (ex VAT)
STN-015-014-100
250
1000
140
white
625/2133
£308
STN-015-014-120
250
1200
140
white
750/2559
£345
STN-015-014-140
250
1400
140
white
875/2986
£383
STN-015-014-150
250
1500
140
white
875/3199
£402
STN-015-014-160
250
1600
140
white
1000/3412
£420
STN-015-014-200
250
2000
140
white
1250/4265
£495
STN-015-020-100
250
1000
200
white
993/3388
£441
STN-015-020-120
250
1200
200
white
1192/4066
£493
STN-015-020-140
250
1400
200
white
1390/4743
£545
STN-015-020-150
250
1500
200
white
1490/5082
£571
STN-015-020-160
250
1600
200
white
1589/5421
£597
STN-015-020-200
250
2000
200
white
1986/6776
£701
Model STOCK listed in black
Zehnder Stana
Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 4-6 weeks.. Accessories
Finish
RRP (ex VAT)
White
£21
Chrome
£23
Model 819080
Zehnder white TRV head (M30 x 1.5)
819088
Zehnder chrome TRV head (M30 x 1.5)
2 5 Zehnder Stana DAY
3-5
DAY
10 31
2
5
WEEKS
3-5
DAY
5-7
DAY
31
10 WEEKS
4-6
10 2
DAY
14
5
10
DAY
30
DAY DAY
20 3-5
DAY
10 31
DAY
5-7
DAY
31
DAY
14
DAY
30
On the floor in front of a window or in an alcove. Zehnder Stana enables ideal distribution of heated air throughout the room. Understated design and a variety of models ensure that Zehnder Stana fits perfectly into any setting. DAY
3-5
DAY
5-7
DAY
14
WEEKS
3-5
WEEKS
4-6
DAY
20
DAY WEEKS
17 3-5
WEEKS
3-5
WEEKS
4-6
DAY
20
Note: TRV Headnot supplied with radiator Refer to website for Stana colour chart
W
100
H
F = flow R = return H = height T = depth W = width L = Length Dimensions in mm 150 50 25 R
F
T
W
70
STN-015-014 STN-015-014
260
175
200
175
175
140
100
Scan the QR code for the Zehnder Stana colour chart. 130
STN-015-020 STN-015-020
Note: comes with integral valve The complete 38
compliant technical specifications can be found between pages 49 and 57.
STN-015-014-140 ANTHRACITE 0346 STN-015-014-160 WHITE 9016
January 2019
39
ELECTRIC RADIATORS
ALURA Electric Heating Model STOCK listed in bold
Height mm
Width mm
Finish
No. of sections
With factory fitted controls, Class ll IPX4 Electric Rating (Watts)
Weight kg
RRP (ex VAT)
372 472 572 772 872 1172
white* white* white* white* white* white*
3 4 5 7 8 11
500 750 1000 1250 1500 2000
7 9 11 15 17 23
£282 £308 £347 £407 £451 £553
2 5 10 Alura Zehnder
Zehnder Alura Electric ALE-050-036/F ALE-075-046/F ALE-100-056/F ALE-125-076/F ALE-150-086/F ALE-200-116/F *white (RAL 9010)
575 575 575 575 575 575
DAY
3-5
2
DAY
5-7
5
DAY
14
10
DAY WEEKS
17 3-5
This fast response electric aluminium radiator has a high output in relation to its size. Its weight and size makes this radiator easy to install, and the straightforward digital controls make it easy and economical to use. H shaped mounting bracket with removable spirit level and locking system included. WEEKS
3-5
DAY WEEKS
3-5 4-6
DAY DAY
5-7 20
DAY
14
DAY WEEKS
17 3-5
Temperature controller: Backlit LCD digital display screen gives complete control. Temperature can be adjusted in 0.5°C increments. 3 pre-set programmes and 5 mode settings. Open window detection system and parental lock.
WEEKS
3-5
H = height W = width All dimensions in mm
W
H
Open Window detection The Integral control unit recognises if a window has been opened for an extended period and switches the radiator off. Once the window is closed, the radiator returns to normal operation. External temperature sensor recognises temperature changes. Integral thermostat reacts to sensor information Radiator automatically switches off if a window is open for an extended period. Intelligent heating that saves energy and costs.
WEEKS
4-6
DAY
20
Alura
ALE-100-056/F PURE WHITE 9010 CHARLESTON & CHARLESTON PLINTH Watts Electric Heating number Radio frequency remote programmer IPX4 Weight RRP Height Width Model STOCK of Finish mm mm Zone 1 Bath, Zone 2 Shower, Class II kg (ex VAT) listed in black sections
Zehnder Charleston & 2 5 10 Charleston Plinth
Zehnder Charleston Electric NZ-060-053/GF NZ-060-062/GF NZ-060-076/GF NZ-060-089/GF NZ-060-103/GF NZ-060-131/GF 576
600 530 600 622 600 760 600 898 600 1036 600 1312 714
10 white 12 white 15 white 18 white 21 white 27 white
500 750 1000 1250 1500 2000
£482 27.0 £562 30.0 41.0 £608 47.0 £710 58.0 £765 £921 70.0
20
1000
42.4
Zehnder Charleston Plinth Electric
NZ-030-100/GF
300
995
white
£800
DAY
Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. 600
600
3-5
DAY
WEEKS
3-5
RRP (ex VAT)
601020594 966018 NZ-060-062/GF 966028
H = height W = width Width includes controller All dimensions in mm
£56.00 £138.00 £154.00
Lambswool732 cleaning brush Charleston towel bar 368mm NZ-060-076/GF Charleston towel bar 918mm
2
WEEKS
4-6
DAY
3-5
DAY
10
DAY
5-7
DAY
14
DAY WEEKS
17 3-5
WEEKS
H
H
600
576
600
600
484
40
5
20
The Zehnder Charleston is an electric, oil-filled multi-column radiator available in 6 sizes ideal for 714 installation in loft conversions. The complementary Zehnder Charleston Plinth low level model is perfectly suited to conservatories and in front of low-level windows. 3-5
F
DAY
14
16
Accessories Model
DAY
5-7
W
W
Charleston Electric
Charleston Plinth NZ-030-100/GF
502 NZ-060-053/GF
594 NZ-060-062/GF
WEEKS
4-6
DAY
20
732
NZ-060-076/GF
NZ-060-089/GF TRAFFIC WHITE 9016 852
990
January 2019
41
EXTRACTOR FANS
Zehnder Low Energy Continuous Fan Ø100mm
100% adjustable speed
er ™ TimART SM
er ™ TimART SM
i midT™ Hu AR SM
Continuous ventilation ensures a continually fresh environment with a constant low level trickle and then boost linked to room usage and often high moisture levels! i midT™ Hu AR SM
This low energy design costs as little as £1.50 to run for the entire year and is quiet running so operates in the background discretely ensuring issues such as mould and condensation are kept at bay. With SMART humidity and timer controls, nuisance noise and running are completely eliminated leaving you to relax in the surroundings of your bathroom. Model STOCK listed in black
Did you know that a shower can create up to 2 pints of moisture? Add this to boiling the kettle, cooking, drying clothes and breathing and there is a lot of moisture in your home, not to mention other airborne particles such as dust and VOC’s!
42
D IP (Spigot) Rating
IPX4 Ceiling 68 IPX5 Wall
Airflow l/s in FREE AIR (BS848 Pt 1)
Speed
Trickle
5
8
Boost
8
13
Maximum
23
23
RRP (ex VAT)
Accessories Wall fan accessories mm
375
ZED1A ZEG1WA
ZFF100W ZFF100B
Plastic wall inner with integral screw-fixing channels Fixed blade louvered external wall vent in white Fixed blade louvered external wall vent in brown Fast fix wall duct system with external grill available in white (W) or brown (B)
£7 £4 £4 £15
Ceiling fan accessories ZGFP4.3A
This range of fans offer high performance extraction, decorative or discreet style and low noise options - all that you need from your bathroom fan.
H
Sound Energy pressure level Consumption (W) Min Max dB(A)
10.1-23.5
1.1
5.4
RRP (ex VAT)
£104
Accessories for all bathroom fans
ZEG1BA
Ventilation is crucial to every home, and especially in bathrooms and kitchens.
W
Continuous trickle speed with boost activated by lightswitch or smart humidity sensing. Optional SMART overrun 199 129.5 timer. Easy set on touch pad located on the fan fascia. Quiet running, low energy design
ZCV2
Ventilation - extractor fans.
Control Operation
Ceiling Application (unit can be wall or ceiling mounted)
ZGG42WA ZGG42BA
Flexiduct 3m x Ø100mm (required for ceiling fitting) 100mm External grille with spigot in white 100mm External grille with spigot in brown
£10 £4 £4
Zehnder Adaptive fan with “smart” timer technology and pull cord option. The length of time of the fan over-run is r based on occupancy duration, up to a me Ti ART SM maximum run-time of 15 minutes, reducing heat idi loss and energy usage. um T r me ™ Ti ART M S
™
H AR SM
™
Zehnder Adaptive fan with “smart” humidistat and timer technology and pull cord option. The fan knows the normal humidity level and only activates when spikes occur, providing the right amount of ventilation when required, unlike fans with a generic point that respond to high ambient humidity on a summer’s day and particularly in the middle of the night. di mi T™ Hu AR SM
All fans suitable for wall or ceiling mounting with discharge through an external wall or soffit, but not the roof. Please see pages 44 and 46 for diagrams. Not for use with more than 3m of ducting.
January 2019
43
EXTRACTOR FANS
SILENT WALL & CEILING FANS Model STOCK listed in black
Description
ZSR100B10A
Silent fan Basic
ZSR100TR11A
Silent fan Timer
ZSR100HTR12A
Silent fan Humidistat
Controls
Airflow l/s in FREE AIR (BS848 Pt 1)
Sound pressure level @ 3m dB(A)
Energy Consumption (W)
IP Rating
RRP (ex VAT)
Single speed. Operation by light/ remote switch
26
26.7
13
IPX4 Zones 1&2
£63
26
26.7
16
IPX4 Zones 1&2
£75
26
26.7
16
IPX4 Zones 1&2
£99
Single speed. Operation by light/ remote switch. Adjustable overrun timer (2-30 mins & preset at 15 mins) Single speed. Automatic operation by humidity control with option for manual override switch. Adjustable humidity (70-90% & set at 70%). Adjustable overrun timer to prevent hunting
Zehnder Silent Wall & Ceiling Fans Ø100mm 3
180mm
33
The range of Zehnder Silent fans offer “whisper-quiet” operation – typically a minimum of 70% less noise than standard fans. This range has been developed in response to customers who want high performance ventilation without nuisance noise. 3 year warranty.
160mm
180mm
Ø 97mm
All fans suitable for wall or ceiling mounting with discharge through an external wall or soffit, but not the roof. Not for use with more than 3m of ducting.
142mm
Standard ceiling installation
ZSR100 wall fans Zehnder Silent Fan - Front Fascia Options
Option 1
Option 2
Option 3
ADAPTIVE WALL & CEILING FANS Airflow l/s in FREE AIR (BS848 Pt 1)
Sound pressure level @ 3m dB(A)
Energy Consumption (W)
Model STOCK listed in black
Description
ZLE100TA
Single speed operation by light/ remote switch or via integral pull cord. Low Energy Adaptive Fan with Adaptable speeds (1-6) to ensure SMART Timer installed performance between 1-6. SMART overrun timer
13.6
31
25
45
1.6
ZLE100HTA
Single speed operation via light/ Low Energy remote switch or via integral pull Adaptive Fan with cord. Adaptable speeds (1-6) to SMART humdistat ensure installed performance. SMART and timer humidity and overrun timer
13.6
31
25
45
1.6
Controls
IP Rating
RRP (ex VAT)
8.9
IPX4 Zones 1&2
£94
8.9
IPX4 Zones 1&2
£140
All fans suitable for wall or ceiling mounting with discharge through an external wall or soffit, but not the roof. Refer to speeds for maximum ducting lengths
100mm fan suitable for through wall and ducted ceiling/wall installation. Installation Through Wall + <3m Ducting <1.5m Ducting Window Kit Through Wall Window Kit <3m Ducting
160
39.8
115 103.5
160
Room WC Bathroom WC Bathroom Bathroom Bathroom
Ø99
Speed 1 2 3 4 5 6
The speed of the fan is set by the installer according to the size and use of the room, thus avoiding over or under ventilation. See standard ceiling installation diagram above.
ZLE100 wall fans
44
Zehnder Adaptive Wall & Ceiling Fans Ø100mm 3
The economical low-energy, quiet Zehnder Adaptive fan offers the latest in extractor fan technology - adaptive extraction - offering 6 pre-set speeds for different installation applications to ensure the fan is doing the job it’s supposed to and eliminating issues with mould and condensation 3 year warranty. January 2019
45
EXTRACTOR FANS
SILENT SHOWER FAN KIT Description
Controls
Airflow l/s in FREE AIR (BS848 Pt 1)
Sound pressure level @ 3m dB(A)
Energy Consumption (W)
IP Rating
RRP (ex VAT)
ZSR100TSKA
Silent Timer Shower Kit
Single speed, 230V. Operation by light/remote switch Adjustable timer. Kit includes induct fan, 90° end,3 metres of Flexiduct, 4 fixing clips, ceiling grills and fixing screws
31
20
16
IPX4 Zones 1&2
£96
ZSR100ETSKA
Single speed, 230V. Operation by light/remote switch. Adjustable timer. Kit includes induct fan, 12V light unit, Silent Timer light transformer, 90° bend, 3 metres Shower Kit & Light of flexiduct, 4 fixing clips, ceiling grille and fixing screws. Provided with white & chrome bezels.
31
20
Fan 16W,12V lamp IPX4 Zones rated at 6W 1&2
£143
Model STOCK listed in black
Length of ductwork should not exceed the length of the ducting supplied Recommended for discharge through an external wall or soffit, but not the roof.
Ø 145mm
Ø 138mm
11.50mm
Ø 99mm
65mm
40mm
Ø 100mm
Zehnder Silent Shower Fan Kit 3
Silent fans are 70% quieter than standard axial fans when operating. Supplied as shower kits with or without a LED light in “warm white” (2700K) and with a 3 year warranty.
11mm
ZSR100TSKA
ZSR100ETSKA Zehnder Silent ø100mm Induct Fans
Soffit installation
HALO DESIGNER SHOWER FAN & LED LIGHT KIT Sound pressure level @ 3m dB(A)
Single speed, 230V. Operation by light/remote switch Adjustable timer (2-30mins and factory set at 15 mins). Kit includes ø125mm induct fan, internal rgrille with low voltage 12V light and transformer, 90° bend, 3 metres of flexiduct, 4 fixing Shower Fan clips, 110 ceiling grill and fixing screws. White & Chrome bezels provided
56
31
£117
71
71 122
Surface cable entry
122
Surface cable entry
162
3
59
Ø119
71
Ø115
115 55.5
Surface cable entry
122 Ø118
162
59
87
Ø119
41.5
87
Ø118
175
41.5
115 55.5
Soffit installation
Zehnder Halo Designer Shower Fan & LED Light Kit Ø125mm
Foot
162
90˚Bend
RRP (ex VAT)
Fan 20W, 12V lamp IPX4 Zones rated at 6W 1&2
90˚Bend
59
IP Rating
Shower Fan 110
Foot
Shower Fan 110 90˚Bend
Energy Consumption (W)
Foot
Ø115
timer ceiling fan shower kit and LED light
Airflow l/s in FREE AIR (BS848 Pt 1)
Ø119
ø125mm Halo ZHC115ETSKA
Controls
Ø115
Description
115 55.5
Model STOCK listed in black
Ø180
175 Ø118
41.5
87
Ø180
Today’s luxurious showers and bathrooms call for high performance and high design. The Zehnder Halo is a ceiling extractor fan supplied as a kit with an integrated LED light in “warm white” (2700K). 3 year warranty.
175
46
Ø180
January 2019
47
ACCESSORIES
TECHNICAL SPECIFICATIONS Valves
Valves, dual energy and electric products
VAL-SET-1-CR Modern angled radiator valve set chrome plated. RRP (ex VAT) £44
VAL-SET-2-CR Contemporary double angled radiator valve set chrome plated. RRP (ex VAT) £61
Zehnder offers you a whole range of well matched valves and accessories to enhance aesthetics of your radiators and towels rails. The option of dual energy installation in the bathroom also guarantees luxury and comfort throughout the year. Electrical elements for Dual Energy installations
DE Pack 100 DE Pack 150 DE Pack 200 DE Pack 300 DE Pack 400 DE Pack 500 DE Pack 600 DE Pack 700 DE Pack 900
Watts
RRP (ex VAT)
100 150 200 300 400 500 600 700 900
VAL-SET-4-CR Mixed dual energy radiator valve set chrome plated. RRP (ex VAT) £44
RRP (ex VAT) £111
VAL-SET-18-CR Dual fuel right hand flow valve set chrome plated.
£139
RRP (ex VAT) £134
VAL-SET-19-CR Dual fuel left hand flow valve set chrome plated.
SHECZ-CR Simple immersion cable cover - chrome finish. RRP (ex VAT) £51
CTEW
RRP (ex VAT) £44
VAL-SET-8-CR Traditional valve set chrome plated.
Simple immersion - no controls IPX5 Model
VAL-SET-3-CR Stylish straight radiator valve set chrome plated.
RRP (ex VAT) £134
VAL-SET-20-CR Thermostatic dual fuel right hand flow valve set chrome plated.
CTEC
RRP (ex VAT) £185
Heat-adjustable, fuel saving electric element with 5 water-temperature settings between 30°C and 60°C: IPX4 Model
Finish
CTEW-120-DF white CTEW-200-DF white CTEW-300-DF white CTEW-400-DF white CTEW-600-DF white White T-piece included CTEC-120-DF chrome CTEC-200-DF chrome CTEC-300-DF chrome CTEC-400-DF chrome CTEC-600-DF chrome Chrome T-piece included 48
Watts 120 200 300 400 600 120 200 300 400 600
RRP (ex VAT)
£159
VAL-SET-21-CR Thermostatic dual fuel left hand flow valve set chrome plated. RRP (ex VAT) £185
Zehnder Aura (page 6) Stock Models Model code
Height mm
Width mm
PBZ-080-040 775 400 PBZ-080-050 775 500 PBZ-080-060 775 600 PBZ-120-050 1217 500 PBZ-120-060 1217 600 PBZ-150-050 1469 500 PBZ-150-060 1469 600 PBZ-180-050 1856 500 PBZ-180-060 1856 600 PBCZ-060-040 607 400 PBCZ-080-040 775 400 PBCZ-080-050 775 500 PBCZ-080-060 775 600 PBCZ-100-050 1027 500 PBCZ-120-040 1217 400 PBCZ-120-050 1217 500 PBCZ-120-060 1217 600 PBCZ-150-040 1469 400 PBCZ-150-050 1469 500 PBCZ-150-060 1469 600 PBCZ-180-040 1856 400 PBCZ-180-050 1856 500 PBCZ-180-060 1856 600 PBCZ-180-075 1856 750 PBZ-080-040-0346 775 400 PBZ-080-050-0346 775 500 PBZ-080-060-0346 775 600 PBZ-120-040-0346 1217 400 PBZ-120-050-0346 1217 500 PBZ-120-060-0346 1217 500 PBZ-180-050-0346 1856 500 PBZ-180-060-0346 1856 500 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C
Finish
Overall Projection mm
white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 Test House: WSP LAB Test House No: 1428
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 356 456 556 456 556 456 556 456 556 356 356 456 556 456 356 456 556 356 456 556 356 456 556 706 356 456 556 356 456 556 456 556
65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75
287 358 418 512 598 631 740 788 925 151 186 230 271 287 278 330 390 346 407 481 432 513 607 741 287 358 418 427 512 598 788 925
979 1221 1426 1747 2040 2153 2525 2689 3156 515 635 785 925 979 949 1126 1331 1181 1389 1641 1473 1750 2071 2527 979 1221 1426 1457 1747 2040 2689 3156
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 152 194 228 273 319 335 395 418 491 79 96 120 143 149 142 171 203 177 211 250 221 264 316 387 152 194 228 227 273 319 418 491
519 662 777 932 1089 1143 1347 1427 1675 269 328 408 488 508 485 583 692 604 718 853 754 901 1077 1321 519 662 778 775 931 1088 1426 1675
1.23 1.20 1.19 1.23 1.23 1.24 1.23 1.24 1.24 1.27 1.27 1.28 1.25 1.28 1.28 1.29 1.28 1.29 1.29 1.28 1.30 1.30 1.28 1.27 1.23 1.2 1.19 1.23 1.23 1.23 1.24 1.24
5.58 5.74 6.2 7.89 8.92 9.79 11.1 12.07 13.67 3.60 5.6 5.76 6.23 6.7 8.0 7.92 8.96 9.8 9.83 11.15 10.45 12.12 13.72 17.20 5.58 5.74 6.2 7 7.89 8.92 12 13.67
3.1 3.6 4.1 5.2 5.9 6.5 7.4 8.0 9.1 2.6 3.1 3.6 4.1 4.5 4.5 5.2 5.9 5.6 6.5 7.4 7.1 8.0 9.1 10.7 3.1 3.6 4.1 4.7 5.2 5.9 8 9.1
200 200 300 300 400 400 500/400 500/400 600 100/n/a 100/n/a 150/120 150/120 200 200 200 300 300 300 300 300 300 400 500 200 200 300 300 300 400 500/400 600
Zehnder Aura Bow (page 10) Stock Models Model code
Height mm
Width mm
PBTZ-080-050 775 494 PBTZ-080-060 775 595 PBTZ-120-050 1217 494 PBTZ-120-060 1217 595 PBTZ-180-050 1856 494 PBTZ-180-060 1856 595 PBTCZ-080-050 775 494 PBTCZ-080-060 775 595 PBTCZ-120-050 1217 494 PBTCZ-120-060 1217 595 PBTCZ-180-050 1856 494 PBTCZ-180-060 1856 595 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C
Finish
Overall Projection mm
white 115 to 125 white 115 to 125 white 115 to 125 white 115 to 125 white 115 to 125 white 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 Test House: WSP LAB Test House No: 1428
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 450 551 450 551 450 551 450 551 450 551 450 551
55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65
358 418 512 598 788 925 230 271 330 390 513 607
1221 1426 1747 2040 2689 3156 785 925 1126 1331 1750 2071
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 194 228 273 319 418 491 125 148 176 208 272 322
662 777 932 1089 1427 1675 425 503 601 710 929 1099
1.20 1.19 1.23 1.23 1.24 1.24 1.20 1.19 1.23 1.23 1.24 1.24
5.54 6.2 7.89 8.92 12.07 13.67 5.76 6.23 7.92 8.96 12.12 13.72
3.6 4.1 5.2 5.9 8.0 9.1 3.6 4.1 5.2 5.9 8.0 9.1
200 300 300 400 500/400 600 150/120 150/120 200 300 300 400
VAL-SET-22-CR Thermostatic angled valve set, chrome plated. RRP (ex VAT) £67
£159
VAL-SET-23-CR Thermostatic straight valve set, chrome plated. RRP (ex VAT) £67
January 2019
49
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Zehnder Charleston (page 24-29)
Zehnder Charleston (page 24-29)
Stock Models Model code
Made to Measure Options Height mm
Width mm
Finish
Overall Projection mm
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
Outputs Water Weight n ∆T=30K Content Exponent kg Watts Btu litres
Vertical 2180-6 1800 306 white/colour 90 length plus valves* 59 744 2539 381 2180-8 1800 398 white/colour 90 length plus valves* 59 992 3385 508 2180-10 1800 490 white/colour 90 length plus valves* 59 1240 4231 635 2180-12 1800 582 white/colour 90 length plus valves* 59 1488 5077 762 3180-6 1800 306 white/colour 128 length plus valves* 78 996 3398 510 3180-8 1800 398 white/colour 128 length plus valves* 78 1328 4531 680 3180-10 1800 490 white/colour 128 length plus valves* 78 1660 5664 850 Horizontal 2050-10 500 490 white/colour 90 length plus valves* 59 384 1310 203 2050-14 500 674 white/colour 90 length plus valves* 59 538 1836 284 2050-18 500 858 white/colour 90 length plus valves* 59 691 2358 365 2050-22 500 1042 white/colour 90 length plus valves* 59 845 2883 446 2050-26 500 1226 white/colour 90 length plus valves* 59 998 3405 527 2060-10 600 490 white/colour 90 length plus valves* 59 453 1546 239 2060-14 600 674 white/colour 90 length plus valves* 59 634 2163 335 2060-18 600 858 white/colour 90 length plus valves* 59 815 2781 430 2060-22 600 1042 white/colour 90 length plus valves* 59 997 3402 527 2060-24 600 1134 white/colour 90 length plus valves* 59 1080 3685 570 2060-28 600 1318 white/colour 90 length plus valves* 59 1260 4299 665 3050-14 500 674 white/colour 128 length plus valves* 78 722 2463 381 3050-18 500 858 white/colour 128 length plus valves* 78 929 3170 491 3050-22 500 1042 white/colour 128 length plus valves* 78 1135 3873 599 3050-26 500 1226 white/colour 128 length plus valves* 78 1342 4579 709 3050-30 500 1410 white/colour 128 length plus valves* 78 1548 5282 817 3060-10 600 490 white/colour 128 length plus valves* 78 609 2078 320 3060-14 600 674 white/colour 128 length plus valves* 78 853 2910 448 3060-18 600 858 white/colour 128 length plus valves* 78 1096 3740 576 128 length plus valves* 78 1220 4163 641 3060-20 600 950 white/colour 3060-24 600 1134 white/colour 128 length plus valves* 78 1464 4995 769 3060-27 600 1272 white/colour 128 length plus valves* 78 1645 5613 864 3060-30 600 1410 white/colour 128 length plus valves* 78 1827 6234 960 3060-34 600 1594 white/colour 128 length plus valves* 78 2071 7066 1088 3075-14 750 674 white/colour 128 length plus valves* 78 1040 3548 546 3075-22 750 1042 white/colour 128 length plus valves* 78 1635 5579 859 3075-26 750 1226 white/colour 128 length plus valves* 78 1932 6592 1015 4030-20 300 950 white/colour 164 length plus valves* 96 840 2866 444 4030-30 300 1410 white/colour 164 length plus valves* 96 1260 4299 665 4060-14 600 674 white/colour 164 length plus valves* 96 1117 3811 584 4060-18 600 858 white/colour 164 length plus valves* 96 1436 4900 751 4060-20 600 950 white/colour 164 length plus valves* 96 1600 5459 836 4060-24 600 1134 white/colour 164 length plus valves* 96 1920 6551 1004 4075-14 750 674 white/colour 164 length plus valves* 96 1364 4654 713 4075-18 750 858 white/colour 164 length plus valves* 96 1753 5981 916 4075-22 750 1042 white/colour 164 length plus valves* 96 2143 7312 1120 4075-26 750 1226 white/colour 164 length plus valves* 96 2532 8639 1323 *Nominal overall radiator length = (Number of sections x 46mm) + 26mm. Please see page 28 for manufacturing tolerances. Max. Working Pressure: 10 bar Test House: WSP-LAB Max. Working Temperature: 110°C Test House No: 2005
50
1300 1733 2167 2600 1740 2320 2900
1.31 1.31 1.31 1.31 1.31 1.31 1.31
16.4 21.9 27.3 32.8 24.6 32.8 41.0
9.0 12.0 15.0 18.0 14.0 19.0 24.0
693 969 1245 1522 1798 815 1143 1467 1798 1945 2269 1300 1675 2044 2419 2788 1092 1529 1965 2187 2624 2948 3276 3712 1863 2931 3463 1515 2269 1993 2562 2852 3426 2433 3125 3821 4514
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.25 1.25 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27
7.9 11.0 14.2 17.4 20.5 9.5 13.3 17.1 20.9 22.8 26.6 16.6 21.4 26.2 30.9 35.7 13.9 19.4 24.9 27.7 33.2 37.3 41.6 47.0 24.3 38.2 45.1 21.3 32.0 27.3 35.1 39.0 46.8 33.6 43.2 52.8 62.5
5.0 7.0 9.0 11.0 13.0 6.0 8.4 10.8 13.2 14.4 16.8 11.2 14.4 17.6 20.8 24.0 9.0 12.6 16.2 18.0 21.6 24.3 27.0 30.6 15.4 24.2 28.6 14.0 21.0 16.8 21.6 24.0 28.8 19.6 25.2 30.8 36.4
Model code
Height mm
Finish
Overall Projection mm
Pipe Centres mm from wall radiator
Outputs ∆T=50K Watts Btu
Outputs Weight n ∆T=30K Exponent kg Watts Btu
2 column 2019 177 white/colour 90 length + valves* 59 14.5 49 7.6 26 2026 260 white/colour 90 length + valves* 59 21.1 72 11.1 38 2030 292 white/colour 90 length + valves* 59 23.6 80.52 12.5 42.65 2035 342 white/colour 90 length + valves* 59 27.5 94 14.5 49 2040 392 white/colour 90 length + valves* 59 31.2 106.45 16.6 56.64 2045 442 white/colour 90 length + valves* 59 34.9 119.08 18.5 63.12 2050 492 white/colour 90 length + valves* 59 38.4 131.02 20.3 69.26 2055 542 white/colour 90 length + valves* 59 41.9 142.96 22.1 75.41 2060 592 white/colour 90 length + valves* 59 45.3 154.56 23.9 81.55 2075 742 white/colour 90 length + valves* 59 55 187.66 29 98.95 2090 892 white/colour 90 length + valves* 59 63.9 218.03 33.7 114.98 2100 992 white/colour 90 length + valves* 59 69.5 237.13 36.7 125.22 2120 1192 white/colour 90 length + valves* 59 82.7 282.17 43.5 148.42 2150 1492 white/colour 90 length + valves* 59 104 354.85 54.1 184.59 2180 1792 white/colour 90 length + valves* 59 124 423.09 63.5 216.66 2200 1992 white/colour 90 length + valves* 59 138 470.86 70.7 241.23 3 column 3019 185 white/colour 128 length + valves* 78 20.1 69 10.5 36 128 length + valves* 78 3026 216 white/colour 27 92 14.6 50 3030 300 white/colour 128 length + valves* 78 32 109.18 16.9 57.66 3035 350 white/colour 128 length + valves* 78 37 126.24 19.5 66.53 3040 400 white/colour 128 length + valves* 78 41.9 142.96 22.1 75.41 3045 450 white/colour 128 length + valves* 78 46.8 159.68 24.7 84.28 3050 500 white/colour 128 length + valves* 78 51.6 176.06 27.2 92.81 3055 550 white/colour 128 length + valves* 78 56.3 192.10 29.6 101.00 3060 600 white/colour 128 length + valves* 78 60.9 207.79 32 109.18 3075 750 white/colour 128 length + valves* 78 74.3 253.51 39 133.07 3090 900 white/colour 128 length + valves* 78 87 296.84 45.5 155.25 3100 1000 white/colour 128 length + valves* 78 95.1 324.48 49.7 169.58 3120 1200 white/colour 128 length + valves* 78 115 392.38 59.5 203.01 3150 1500 white/colour 128 length + valves* 78 140 477.68 71.7 244.64 3180 1800 white/colour 128 length + valves* 78 166 566.39 84.1 286.95 183 624.40 92.8 316.63 3200 2000 white/colour 128 length + valves* 78 4 column 4019 200 white/colour 164 length + valves* 96 28.4 97 14.8 50 4026 260 white/colour 164 length + valves* 96 36.5 125 19.1 65 4030 300 white/colour 164 length + valves* 96 41.9 142.96 22.1 75.41 4035 350 white/colour 164 length + valves* 96 48.5 165.48 25.6 87.35 4040 400 white/colour 164 length + valves* 96 54.9 187.32 28.8 98.27 4045 450 white/colour 164 length + valves* 96 61.3 209.16 32.2 109.87 4050 500 white/colour 164 length + valves* 96 67.6 230.65 35.5 121.13 4055 550 white/colour 164 length + valves* 96 73.7 251.46 38.7 132.04 4060 600 white/colour 164 length + valves* 96 79.8 272.28 41.7 142.28 4075 750 white/colour 164 length + valves* 96 97.4 332.33 50.9 173.67 4090 900 white/colour 164 length + valves* 96 114 388.97 59.3 202.33 4100 1000 white/colour 164 length + valves* 96 125 426.50 64.7 220.76 4120 1200 white/colour 164 length + valves* 96 147 501.56 75.7 258.29 4150 1500 white/colour 164 length + valves* 96 180 614.16 92.2 314.59 4180 1800 white/colour 164 length + valves* 96 213 726.76 108 368.50 234 798.41 119.2 406.71 4200 2000 white/colour 164 length + valves* 96 5 column 5030 300 white/colour 202 length + valves* 115 51.7 176.40 27.3 93.15 5040 400 white/colour 202 length + valves* 115 67.9 231.67 35.7 121.81 5045 450 white/colour 202 length + valves* 115 75.8 258.63 39.8 135.80 5050 500 white/colour 202 length + valves* 115 83.5 284.90 43.6 148.76 5055 550 white/colour 202 length + valves* 115 91.1 310.83 47.6 162.41 5060 600 white/colour 202 length + valves* 115 98.6 336.42 51.5 175.72 5075 750 white/colour 202 length + valves* 115 120 409.44 62.1 211.89 5090 900 white/colour 202 length + valves* 115 141 481.09 72.6 247.71 5100 1000 white/colour 202 length + valves* 115 154 525.45 79.3 270.57 5120 1200 white/colour 202 length + valves* 115 179 610.75 91.7 312.88 219 747.23 111.6 380.78 5150 1500 white/colour 202 length + valves* 115 6 column 6030 300 white/colour 238 length + valves* 115 61.3 209.16 32.2 109.87 6035 350 white/colour 238 length + valves* 115 71 242.25 37.3 127.27 6040 400 white/colour 238 length + valves* 115 80.5 274.67 42.1 143.65 6045 450 white/colour 238 length + valves* 115 89.8 306.40 46.9 160.02 6050 500 white/colour 238 length + valves* 115 99 337.79 51.5 175.72 6055 550 white/colour 238 length + valves* 115 108 368.50 56.2 191.75 6060 600 white/colour 238 length + valves* 115 117 399.20 60.5 206.43 6075 750 white/colour 238 length + valves* 115 143 487.92 73.6 251.12 6090 900 white/colour 238 length + valves* 115 167 569.80 85.5 291.73 6100 1000 white/colour 238 length + valves* 115 183 624.40 93.7 319.70 6120 1200 white/colour 238 length + valves* 115 210 716.52 107 365.08 256 873.47 130.4 444.92 6150 1500 white/colour 238 length + valves* 115 *Nominal overall radiator length = (Number of sections x 46mm) + 26mm. Please see page 28 for manufacturing tolerances. Vertical entry = overall length minus 72mm Max. Working Pressure: 4 bar Test House: WSP-LAB Max. Working Temperature: 110°C Test House No: 1428
Water Content litres
1.26 1.25 1.24 1.24 1.24 1.24 1.25 1.25 1.25 1.25 1.25 1.25 1.26 1.28 1.31 1.31
0.32 0.44 0.5 0.57 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.9 2.3 2.7 3.0
0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.1 1.3 1.5 1.7
1.27 1.25 1.25 1.25 1.25 1.25 1.25 1.26 1.26 1.26 1.27 1.27 1.29 1.31 1.33 1.33
0.49 0.66 0.7 0.9 1.0 1.1 1.2 1.3 1.4 1.7 2.1 2.3 2.8 3.4 4.1 4.5
0.4 0.5 0.6 0.6 0.7 0.7 0.8 0.9 0.9 1.1 1.3 1.4 1.6 2.0 2.4 2.6
1.26 1.25 1.25 1.25 1.26 1.26 1.26 1.26 1.27 1.27 1.28 1.29 1.30 1.31 1.33 1.32
0.67 0.84 1.0 1.2 1.4 1.5 1.7 1.9 2.0 2.5 2.9 3.2 3.7 4.4 5.2 5.8
0.6 0.7 0.7 0.8 0.9 1.0 1.0 1.1 1.2 1.4 1.7 1.8 2.1 2.6 3.1 3.4
1.25 1.26 1.26 1.27 1.27 1.27 1.29 1.30 1.30 1.31 1.32
1.3 1.7 1.9 2.1 2.3 2.5 3.1 3.6 3.9 4.6 5.6
0.9 1.1 1.2 1.3 1.4 1.5 1.8 2.1 2.3 2.7 3.3
1.26 1.26 1.27 1.27 1.28 1.28 1.29 1.30 1.31 1.31 1.32 1.32
1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.5 4.2 4.6 5.5 6.8
1.1 1.2 1.3 1.4 1.5 1.6 1.8 2.1 2.5 2.7 3.2 4.0
January 2019
51
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Zehnder Klaro (page 12)
Zehnder Lyta-T (page 34)
Stock Models Model code
Stock Models Height mm
Width mm
ZSL-080-045 748 450 ZSL-120-050 1148 500 ZSL-120-060 1148 600 ZSL-150-050 1466 500 ZSL-150-060 1466 600 ZSL-170-050 1708 500 ZSL-170-060 1708 600 Max. Working Pressure: 4 bar Max. Working Temperature: 110°C
Finish
Overall Projection mm
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 Test House: HLK STUTTGART Test House No: 0626
412 462 562 462 562 462 562
68 to 83 68 to 83 68 to 83 68 to 83 68 to 83 68 to 83 68 to 83
354 571 670 716 839 824 966
1208 1948 2286 2443 2863 2811 3296
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 187 298 352 372 436 424 502
638 1017 1201 1269 1488 1447 1713
1.25 1.27 1.26 1.28 1.28 1.30 1.28
5.4 8.7 9.8 10.9 12.3 12.2 14.2
3.6 5.8 6.6 7.4 8.5 8.5 9.6
200 400 500/400 500/400 500/400 500/400 600
Model code
Height mm
Width mm
LYTV-Z-097-032 966 320 LYTV-Z-097-048 966 480 LYTV-Z-147-032 1466 320 LYTV-Z-147-048 1466 480 LYTV-Z-187-024 1866 240 LYTV-Z-187-032 1866 320 LYTV-Z-187-040 1866 400 LYTV-Z-187-048 1866 480 *white (RAL 9010) Max. Working Pressure: 6 bar Max. Working Temperature: 120°C
Finish
Overall Projection mm
white* white* white* white* white* white* white* white*
110 to 140 110 to 140 110 to 140 110 to 140 110 to 140 110 to 140 110 to 140 110 to 140
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 344 plus valves 504 plus valves 344 plus valves 504 plus valves 264 plus valves 344 plus valves 424 plus valves 504 plus valves
82 82 82 82 82 82 82 82
728 1092 1000 1500 900 1200 1500 1800
Outputs Water Weight n ∆T=30K Content Exponent kg Watts Btu litres
2484 3726 3412 5118 3071 4094 5118 6142
362 542 499 749 442 590 737 885
1234 1851 1703 2555 1510 2013 2516 3019
1.37 1.37 1.39 1.39 1.39 1.39 1.39 1.39
7.8 11.8 11.2 16.8 10.2 13.6 17.0 20.4
1.7 2.6 2.5 3.7 2.3 3.1 3.9 4.7
Test House: Laboratorio Misure Ricerche Termotecniche Test House No: 1695
Zehnder Kleo (page 30) Stock Models Model code
Height mm
Width mm
Vertical KLV-180-030 1800 299 KLV-180-040 1800 398 KLV-180-050 1800 497 KLV-180-060 1800 596 KLVC-180-030 1800 299 KLVC-180-040 1800 398 KLVC-180-050 1800 497 KLVC-180-060 1800 596 Horizontal KLH-058-100 596 1000 KLH-058-120 596 1200 KLH-058-140 596 1400 KLHD-058-100 596 1000 KLHD-058-120 596 1200 KLHD-058-140 596 1400 Max. Working Pressure: 4 bar Max. Working Temperature: 110°C
Finish
white/colour white/colour white/colour white/colour chrome chrome chrome chrome
Overall Projection mm
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
Outputs Weight n ∆T=30K Exponent kg Watts Btu
Water Content litres
74 74 74 74 74 74 74 74
248 347 446 545 248 347 446 545
38 38 38 38 38 38 38 38
632 842 1053 1264 448 598 747 896
2156 2874 3593 4313 1529 2040 2549 3057
329 438 548 647 225 300 375 450
1123 1494 1870 2209 768 1024 1280 1535
1.28 1.28 1.28 1.28 1.35 1.35 1.35 1.35
10.8 14.4 18.0 21.6 10.8 14.4 18.0 21.6
4.5 6.1 7.5 9.0 4.5 6.1 7.5 9.0
white/colour 74 white/colour 74 white/colour 74 white/colour 106 white/colour 106 white/colour 106 Test House: CETIAT Test House No: 1623
962 1162 1362 962 1162 1362
38 38 38 38 38 38
782 938 1095 1211 1453 1695
2668 3201 3736 4134 4961 5787
413 495 578 636 763 891
1409 1689 1972 2170 2603 3040
1.25 1.25 1.25 1.26 1.26 1.26
12.7 14.9 17.1 22.6 27.1 31.6
5.5 6.6 7.7 12.5 15.0 17.5
Zehnder Muralis (page 14) Stock Models Model code
Height mm
Width mm
MUR-080-050-0346 800 500 MUR-100-050-0346 1000 500 MUR-120-050-0346 1200 500 MUR-140-050-0346 1400 500 MUR-160-050-0346 1600 500 MURC-080-050 800 500 MURC-100-050 1000 500 MURC-120-050 1200 500 MURC-140-050 1400 500 MURC-160-050 1600 500 Max. Working Pressure: 4 bar Max. Working Temperature: 120°C
Finish
Overall Projection mm
anthracite 80 anthracite 80 anthracite 80 anthracite 80 anthracite 80 chrome 80 chrome 80 chrome 80 chrome 80 chrome 80 Test House: WSP LAB Test House No: 1428
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 470 470 470 470 470 470 470 470 470 470
65-90 65-90 65-90 65-90 65-90 65-90 65-90 65-90 65-90 65-90
306 384 461 537 612 197 249 301 346 391
1044 1310 1573 1832 2088 672 850 1027 1181 1334
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 164 204 245 284 324 103 130 156 179 202
558 697 835 971 1107 351 442 534 612 690
1.20 1.21 1.22 1.22 1.22 1.25 1.26 1.26 1.26 1.27
5.6 7.0 8.4 9.6 10.9 5.5 7.0 8.4 9.6 10.8
3.30 4.10 4.90 5.70 6.40 3.30 4.10 4.90 5.70 6.40
200/200 200/200 300/300 300/300 400/400 150/120 200/200 200/200 200/200 300/300
Zehnder Lyta-S (page 32) Stock Models Model code
Height mm
Width mm
LYSV-Z-040-048 395 480 LYSV-Z-040-064 395 640 LYSV-Z-040-080 395 800 LYSV-Z-040-096 395 960 LYSV-Z-040-112 395 1120 LYSV-Z-055-048 545 480 LYSV-Z-055-064 545 640 LYSV-Z-055-080 545 800 LYSV-Z-055-096 545 960 LYSV-Z-055-112 545 1120 LYSV-Z-065-048 645 480 LYSV-Z-065-064 645 640 LYSV-Z-065-080 645 800 LYSV-Z-065-096 645 960 LYSV-Z-065-112 645 1120 *white (RAL 9010) Max. Working Pressure: 24 bar Max. Working Temperature: 120°C
52
Finish
Overall Projection mm
white* white* white* white* white* white* white* white* white* white* white* white* white* white* white*
130 130 130 130 130 130 130 130 130 130 130 130 130 130 130
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 504 plus valves 664 plus valves 824 plus valves 984 plus valves 1144 plus valves 504 plus valves 664 plus valves 824 plus valves 984 plus valves 1144 plus valves 504 plus valves 664 plus valves 824 plus valves 984 plus valves 1144 plus valves
82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
546 728 910 1092 1274 737 983 1229 1475 1721 848 1131 1414 1697 1980
1863 2484 3105 3726 4347 2516 3355 4193 5032 5871 2895 3860 4824 5789 6754
Outputs Water Weight n ∆T=30K Content Exponent kg Watts Btu litres 283 377 471 565 659 381 509 636 763 890 435 581 726 871 1016
964 1286 1607 1929 2250 1302 1736 2170 2604 3038 1486 1982 2477 2973 3468
1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.30 1.30 1.30 1.30 1.30
6.6 8.8 11.0 13.2 15.4 8.4 11.2 14.0 16.8 19.6 9.6 12.8 16.0 19.2 22.4
1.44 1.92 2.40 2.88 3.36 1.5 2.0 2.5 3.0 3.5 1.8 2.4 3.0 3.6 4.2
Test House: Laboratorio Misure Ricerche Termotecniche Test House No: 1695
January 2019
53
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Zehnder Roda (page 36)
Zehnder Roda (page 38)
Stock Models Model code
Made to Measure Options Height mm
Width mm
Finish
Overall Projection mm
Zehnder Roda vertical single panel ROV-180-029 1800 296 white/colour 70 ROV-180-037 1800 370 white/colour 70 ROV-180-044 1800 444 white/colour 70 ROV-180-051 1800 518 white/colour 70 ROV-180-059 1800 592 white/colour 70 ROV-180-066 1800 666 white/colour 70 Zehnder Roda vertical double panel ROVD-180-029 1800 296 white/colour 93 ROVD-180-037 1800 370 white/colour 93 ROVD-180-044 1800 444 white/colour 93 ROVD-180-051 1800 518 white/colour 93 ROVD-180-059 1800 592 white/colour 93 ROVD-180-066 1800 666 white/colour 93 Zehnder Roda horizontal single panel ROH-052-100 518 1000 white/colour 70 ROH-052-120 518 1200 white/colour 70 ROH-059-080 592 800 white/colour 70 ROH-059-100 592 1000 white/colour 70 ROH-059-120 592 1200 white/colour 70 ROH-059-140 592 1400 white/colour 70 Zehnder Roda horizontal single panel with single convector fin ROHL-052-100 518 1000 white/colour 70 ROHL-052-120 518 1200 white/colour 70 ROHL-059-060 592 600 white/colour 92 ROHL-059-080 592 800 white/colour 92 ROHL-059-100 592 1000 white/colour 92 ROHL-059-120 592 1200 white/colour 92 ROHL-059-140 592 1400 white/colour 70 ROHL-059-160 592 1600 white/colour 70 Zehnder Roda horizontal double panel ROHD-059-060 592 600 white/colour 93 ROHD-059-080 592 800 white/colour 93 ROHD-059-100 592 1000 white/colour 93 ROHD-059-120 592 1200 white/colour 93 Max. Working Pressure: 4 bar Test House: CETIAT Max. Working Temperature: 110°C Test House No: 1623
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
Outputs n Weight ∆T=30K Exponent kg Watts Btu
Water Content litres
42 42 42 42 42 42
568 710 852 994 1136 1278
1940 2425 2910 3395 3880 4365
291 364 436 509 582 654
993 1242 1488 1737 1986 2231
1.31 1.31 1.31 1.31 1.31 1.31
12 15 18 21 24 27
4.6 5.75 6.9 8.05 9.2 10.35
247 321 395 469 543 617
66 66 66 66 66 66
824 1030 1236 1442 1648 1854
2812 3515 4218 4921 5624 6327
420 525 630 735 840 945
1433 1791 2150 2508 2866 3224
1.32 1.32 1.32 1.32 1.32 1.32
22.4 28 33.6 39.2 44.8 50.4
8.6 10.75 12.9 15.05 17.2 19.35
932 1132 732 932 1132 1332
42 42 42 42 42 42
586 703 532 665 798 931
1999 2399 1815 2269 2723 3177
305 366 277 346 415 484
1041 1249 945 1181 1416 1651
1.28 1.28 1.28 1.28 1.28 1.28
13.4 16.1 11.39 14.1 18.1 19.7
4.9 5.88 4.48 5.6 6.72 7.84
932 1132 532 732 932 1132 1332 1532
62 62 62 62 62 62 62 52
3163 3794 636 848 1060 1272 1504 1718
491 589 2170 2894 3617 4340 5132 5862
491 589 334 446 557 668 792 905
1675 2010 1140 1522 1900 2279 2702 3088
1.24 1.24 1.26 1.26 1.26 1.26 1.26 1.26
18 21.59 13.2 17.6 22 26.4 30.72 35.1
4.9 5.88 3.36 4.48 5.6 6.72 7.85 8.96
532 732 932 1132
66 66 66 66
641 855 1069 1283
2187 2916 3645 4374
337 449 562 674
1150 1532 1918 2300
1.26 1.26 1.26 1.26
16.5 22 27.4 32.9
6.04 8.05 10.06 12.07
ROHL-014
Finish
Overall Projection mm
Pipe Centres mm radiator from wall
Zehnder Roda ROV single, data per vertical tube ROV-060 600 white/colour 70 length minus 49 ROV-080 800 white/colour 70 length minus 49 ROV-100 1000 white/colour 70 length minus 49 ROV-120 1200 white/colour 70 length minus 49 ROV-140 1400 white/colour 70 length minus 49 ROV-160 1600 white/colour 70 length minus 49 ROV-180 1800 white/colour 70 length minus 49 ROV-200 2000 white/colour 70 length minus 49 ROV-220 2200 white/colour 70 length minus 49 Zehnder Roda ROVD double, data per vertical tube ROVD-060 600 white/colour 93 length minus 49 ROVD-080 800 white/colour 93 length minus 49 ROVD-100 1000 white/colour 93 length minus 49 ROVD-120 1200 white/colour 93 length minus 49 ROVD-140 1400 white/colour 93 length minus 49 ROVD-160 1600 white/colour 93 length minus 49 ROVD-180 1800 white/colour 93 length minus 49 ROVD-200 2000 white/colour 93 length minus 49 ROVD-220 2200 white/colour 93 length minus 49 To calculate the number of tubes required, allow 74mm per tube Max. Working Pressure: 4 bar Test House: CETIAT Max. Working Temperature: 110°C Test House No: 1623
54
Finish
Overall Projection mm
Pipe Centres mm radiator from wall
Outputs ∆T=50K Watts Btu
Outputs Weight n ∆T=30K Exponent kg Watts Btu
Water Content litres
Outputs ∆T=50K Watts Btu
Outputs Weight n ∆T=30K Exponent kg Watts Btu
length minus 68
62
350
1194
195
665
1.15
7.0
1.40
ROHL-022 222 white/colour 92 length minus 68 ROHL-030 296 white/colour 92 length minus 68 ROHL-037 370 white/colour 92 length minus 68 ROHL-044 444 white/colour 92 length minus 68 ROHL-052 518 white/colour 92 length minus 68 ROHL-060 592 white/colour 92 length minus 68 ROHL-067 666 white/colour 92 length minus 68 ROHL-074 740 white/colour 92 length minus 68 Zehnder Roda ROH single, data per linear metre ROH-030 296 white/colour 70 length minus 68 ROH-037 370 white/colour 70 length minus 68 ROH-044 444 white/colour 70 length minus 68 ROH-052 518 white/colour 70 length minus 68 ROH-060 592 white/colour 70 length minus 68 ROH-067 666 white/colour 70 length minus 68 ROH-074 740 white/colour 70 length minus 68 Max. Working Pressure: 4 bar Test House: CETIAT Max. Working Temperature: 110°C Test House No: 1623
148
white/colour
92
62 62 62 62 62 62 62 62
511 637 719 845 927 1060 1157 1237
1744 2173 2453 2883 3163 3617 3945 4218
268 334 374 448 492 558 608 650
914 1140 1276 1529 1679 1904 2073 2217
1.26 1.27 1.28 1.24 1.24 1.26 1.26 1.26
10.7 14.3 16.1 18.7 19.5 23.6 24.7 26.5
2.10 2.80 3.50 4.20 4.90 5.60 6.3 7.0
42 42 42 42 42 42 42
344 425 506 586 665 744 823
1174 1450 1726 1999 2269 2537 2806
179 221 264 305 347 387 428
611 754 901 1041 1184 1320 1459
1.28 1.28 1.28 1.28 1.28 1.28 1.28
7.2 9.0 10.7 12.4 14.1 16.0 17.8
2.80 3.50 4.20 4.90 5.60 6.3 7.0
Zehnder Stana (page 40) Stock Models Model code
Made to Measure Options Height mm
Height mm
Zehnder Roda ROHL single with convector fins, data per linear metre 247 321 395 469 543 617
Zehnder Roda (page 38) Model code
Model code
Water Content litres
42 42 42 42 42 42 42 42 42
52 68 83 98 113 127 142 155 169
177 232 283 334 386 433 485 529 577
26 34 42 50 58 65 73 80 87
89 116 143 171 198 222 249 273 297
1.30 1.55 1.32 1.32 1.31 1.31 1.31 1.31 1.31
1.3 1.6 1.9 2.1 2.4 2.7 3.0 3.3 3.6
0.5 0.6 0.7 0.8 0.9 1.0 1.2 1.3 1.4
66 66 66 66 66 66 66 66 66
77 100 122 144 165 186 206 225 244
263 341 416 491 563 635 703 768 833
39 51 62 73 84 95 105 115 124
133 174 212 249 287 324 358 392 423
1.33 1.33 1.33 1.33 1.33 1.32 1.32 1.32 1.32
2.1 2.7 3.3 3.9 4.4 5.0 5.6 6.2 6.7
0.8 1.0 1.3 1.5 1.7 1.9 2.2 2.4 2.6
Height mm
Width mm
STN-015-014-100 250 1000 STN-015-014-120 250 1200 STN-015-014-140 250 1400 STN-015-014-150 250 1500 STN-015-014-160 250 1600 STN-015-014-200 250 2000 STN-015-020-100 250 1000 STN-015-020-120 250 1200 STN-015-020-140 250 1400 STN-015-020-150 250 1500 STN-015-020-160 250 1600 STN-015-020-200 250 2000 Max. Working Pressure: 10 bar Max. Working Temperature: 110°C
Depth mm 140 140 140 140 140 140 200 200 200 200 200 200
Finish
Overall Pipe Centres mm projection radiator (mm)
9016 140 9016 140 9016 140 9016 140 9016 140 9016 140 9016 200 9016 200 9016 200 9016 200 9016 200 9016 200 Test House: WSP-LAB Test House No: 1428
50 50 50 50 50 50 50 50 50 50 50 50
Outputs ∆T=50K Watts Btu 625 750 875 938 1000 1250 993 1192 1390 1490 1589 1986
2133 2559 2986 3200 3412 4265 3388 4067 4743 5084 5422 6776
Outputs ∆T=30K Watts Btu 304 365 425 456 486 608 474 569 664 711 758 948
1037 1245 1450 1556 1658 2074 1617 1941 2266 2426 2586 3235
Weight kg 11.7 14 16.4 17.6 18.7 23.4 14.2 17 19.9 21.3 22.7 28.4
Water Content litres 1 1.3 1.6 1.7 1.8 2.3 1.7 2.1 2.5 2.7 2.9 3.8
January 2019
55
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Zehnder Stellar (page 16)
Zehnder Zeta (page 20)
Stock Models Model code
Stock Models Height mm
Width mm
STNI-060-045 572 450 STNI-060-100 572 1000 STNI-080-030 788 300 STNI-080-045 788 450 STNI-080-060 788 600 STNI-120-030 1220 300 STNI-120-045 1220 450 STNI-120-060 1220 600 STNI-150-045 1508 450 STNI-150-060 1508 600 STNI-170-045 1724 450 STNI-170-060 1724 600 STNI-060-045-CF 572 450 STNI-060-100-CF 572 1000 STNI-080-030-CF 788 300 STNI-080-045-CF 788 450 STNI-080-060-CF 788 600 STNI-120-030-CF 1220 300 STNI-120-045-CF 1220 450 STNI-120-060-CF 1220 600 STNI-150-045-CF 1508 450 STNI-150-060-CF 1508 600 STNI-170-045-CF 1724 450 STNI-170-060-CF 1724 600 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C
Finish
Overall Projection mm
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 Test House: HLK STUTTGART Test House No: 0626
420 970 270 420 570 270 420 570 420 570 420 570 420 970 270 420 570 270 420 570 420 570 420 570
75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85
159 284 159 206 253 242 316 391 389 491 452 545 233 430 232 317 395 353 482 600 591 736 672 838
541 970 541 702 863 826 1078 1334 1327 1675 1542 1860 795 1467 792 1082 1348 1204 1645 2047 2016 2511 2293 2859
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 84 152 85 109 135 129 166 208 206 258 241 288 125 231 124 170 212 188 258 322 315 393 359 449
287 519 290 372 459 440 567 710 703 882 822 983 426 787 424 580 723 643 882 1098 1076 1340 1223 1533
1.24 1.22 1.23 1.24 1.23 1.23 1.26 1.24 1.24 1.26 1.23 1.25 1.22 1.23 1.23 1.22 1.22 1.23 1.23 1.22 1.23 1.23 1.23 1.23
3.3 5.8 3.6 4.5 5.4 5.5 6.9 8.4 8.5 10.2 10.0 12.0 3.3 5.8 3.6 4.5 5.4 5.5 6.9 8.4 8.5 10.2 10.0 12.0
2.0 3.6 2.2 2.8 3.4 3.5 4.3 5.2 5.1 6.2 6.1 7.2 2.0 3.6 2.2 2.8 3.4 3.5 4.3 5.2 5.1 6.2 6.1 7.2
100/n/a 200 100/n/a 150/120 150/120 150/120 150/120 200 300 300 300 400 100/n/a 200 100/n/a 150/120 150/120 150/120 150/120 200 300 300 300 400
Model code
Height mm
Width mm
PQ6-080-050 800 500 PQ6-120-050 1200 500 PQ6-160-050 1600 500 PQ6-080-050-0346 800 500 PQ6-120-050-0346 1200 500 PQ6-160-050-0346 1600 500 PQ6C-080-050 800 500 PQ6C-080-060 800 600 PQ6C-120-050 1200 500 PQ6C-120-060 1200 600 PQ6C-160-050 1600 500 PQ6C-160-060 1600 600 Max. Working Pressure: 4 bar Max. Working Temperature: 120°C
Finish
Overall Projection mm
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
white 81 white 81 white 81 anthracite 81 anthracite 81 anthracite 81 chrome 81 chrome 81 chrome 81 chrome 81 chrome 81 chrome 81 Test House: HLK STUTTGART Test House No: 0626
468 468 468 468 468 468 468 568 468 568 468 568
65 65 65 65 65 65 65 65 65 65 65 65
324 476 647 324 476 647 203 235 302 350 395 457
1105 1624 2208 1105 1624 2208 689 792 1034 1204 1344 1559
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 172 253 345 172 253 345 107 124 157 184 206 239
587 863 1177 587 863 1177 365 423 536 628 703 815
1.24 1.24 1.23 1.24 1.24 1.23 1.26 1.25 1.28 1.26 1.27 1.27
6.4 10.1 13.3 6.4 10.1 13.3 6.4 7.4 10.0 11.4 13.2 15.3
2.2 3.7 4.6 2.2 3.7 4.6 2.2 2.6 3.7 4.4 4.6 5.5
200 300 400 200 300 400 200 200 300 400 400 400
Zehnder Stellar Spa (page 18) Stock Models Model code
Height mm
Width mm
STGI-060-045 572 450 STGI-060-100 572 1000 STGI-080-030 788 300 STGI-080-045 788 450 STGI-080-060 788 600 STGI-120-030 1220 300 STGI-120-045 1220 450 STGI-120-060 1220 600 STGI-150-045 1508 450 STGI-150-060 1508 600 STGI-170-045 1724 450 STGI-170-060 1724 600 STGI-060-045-CF 572 450 STGI-060-100-CF 572 1000 STGI-080-030-CF 788 300 STGI-080-045-CF 788 450 STGI-080-060-CF 788 600 STGI-120-030-CF 1220 300 STGI-120-045-CF 1220 450 STGI-120-060-CF 1220 600 STGI-150-045-CF 1508 450 STGI-150-060-CF 1508 600 STGI-170-045-CF 1724 450 STGI-170-060-CF 1724 600 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C
56
Finish
Overall Projection mm
Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu
s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 Test House: HLK STUTTGART Test House No: 0626
420 970 270 420 570 270 420 570 420 570 420 570 420 970 270 420 570 270 420 570 420 570 420 570
75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85
161 272 171 220 243 240 309 379 361 448 434 517 219 394 218 294 363 332 448 554 556 687 640 791
549 928 583 751 829 819 1054 1293 1232 1529 1481 1764 747 1344 744 1003 1239 1133 1529 1890 1897 2344 2184 2699
Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 84 144 89 115 128 125 161 197 187 233 226 270 117 211 117 158 194 177 239 294 297 367 343 422
287 491 304 392 435 427 549 672 639 795 771 921 401 721 399 538 661 604 815 1003 1012 1251 1171 1440
1.27 1.24 1.28 1.27 1.26 1.28 1.28 1.28 1.28 1.28 1.28 1.27 1.23 1.23 1.23 1.23 1.23 1.23 1.24 1.24 1.24 1.24 1.23 1.23
3.1 5.3 3.4 4.2 5.0 5.2 6.5 7.7 7.8 9.3 9.4 11.2 3.1 5.3 3.4 4.2 5.0 5.2 6.5 7.7 7.8 9.3 9.4 11.2
1.8 3.0 2.0 3.0 3.2 3.1 3.9 4.6 4.7 5.6 5.3 6.5 1.8 3.0 2.0 3.0 3.2 3.1 3.9 4.6 4.7 5.6 5.3 6.5
100 150/120 100 100 150/120 150/120 150/120 200 300 300 200 300 100/n/a 150/120 100/n/a 100/n/a 150/120 150/120 150/120 200 300 300 200 300
January 2019
57
Charleston Technoline Finish Everything you need to know... Typically the four column radiator would look as below.
Zehnder Charleston in Technoline finish essentially shows unique colour and surface appearance for each radiator. This is due to different manufacturing processes and welding technologies (LaZer welding for the headers and projection welding or soldering for the header-tube connection), so each radiator is one of a kind! Header: Marks at the top of the header Occurrence: On each header / on some headers Height: For all heights Reason for appearance: Securing of the sections during welding processes
Header: LaZer welding - silver coloured Header Tube Connection: Projection welding - visible grinding marks Occurrence: 2-6 Columns Height: 400mm or over Reason for appearance: LaZer and projection welding technology
Typically the two column radiator would look as above.
Header: Silver coloured Header Tube Connection: Soldering â&#x20AC;&#x201C; darker coloured (brown/blue) Occurrence: 2-6 columns Height: 400mm or under Reason for the appearance: Soldering
Header: Silver coloured Header Tube Connection: Scratches on the radiator visible beneath the clear lacquer Occurrence: On each section / on some sections /on no section Reason for the appearance: Pre-exisitng scratches on the delivered raw material / securing of the sections during welding processes
Typically the four column, under 400m in height radiator would look as below.
Header: LaZer welding seam is visible on the side Header Tube Connection: Projection welding - silver coloured Occurrence: On each section / on some sections / on no section Height: 400mm or over Reason for appearance: The seam is due to the laZer welding process
58
Typically the three column radiator would look as above.
January 2019
59
Charleston LaZer made, the high-tech, residue-free welding method The fact that Zehnder Charleston has become a radiator classic is not surprising due to its impressive innovation. Even today it boasts a unique new feature: the manufacturing of Zehnder Charleston with LaZer made. This innovative laser welding method for the production of sectional radiators is setting new standards for quality and technology in terms of precision, quality and functionality. Thanks to LaZer made, manufacturing can be more precise than ever before – all without residues inside the radiator or offsets on its surfaces. This makes for an even more attractive appearance and optimised radiator operation. For more benefits, see the information on the right.
Smooth operation, less hassle
The application of this new laser welding method ensures completely clean welding. It guarantees that absolutely no residues remain inside the radiator – this prevents the valves and heat generators from potentially becoming blocked. For you, this means reliable operation and less time required to flush out the heating system. Old
New
Top quality, enhanced appearance
Continuous inspection by a 3D co-ordinate measuring machine prevents even the smallest dimensional nonconformities. To ensure absolute tightness, each unfinished structure is subjected to testing in a test bath both during the production process and in the final stage of manufacturing. The unique production method enables leakproof radiators and clean contours free of offsets. The resulting smooth surfaces are easier to clean.
Sustainable manufacturing, made in Germany Improved energy efficiency, environmental friendliness and sustainability. Because the new laser welding technology requires less energy than the previous method, Zehnder Charleston boasts a satisfyingly low CO2 footprint. With the “made in Germany” manufacturing label, Zehnder is dedicated to its production site in Lahr as well as to short transportation distances and ensured sustainability.
More efficient processes, even faster and more reliable delivery
Tube machining is performed directly on the automatically delivered tube bundles. This removes the need for any interruptions between the production stages and speeds up the manufacturing process. Your radiators are therefore delivered to your project site even faster and are guaranteed to arrive on the agreed date.
3
WEEKS
Scan the QR code to watch the Zehnder LaZer welding made process
60
January 2019
61
Colour System
ystem Colour System
al
Natural Natural
Architectural Architectural
White Quartz Matt White 0521 0556 - Matt
Pure White White Quartz 9210 - Matt 0521 9010 - Glossy
Pure White Look Aluminium 9210 - Matt 9551* 9010 - Glossy
Inox Look Look Aluminium 0332 - Glossy 9551*
Inox Look 0332 - Glossy
Edelweiss 0067 - Matt
Cream 9201 - Matt 9001 - Glossy
Pergamon 0281 - Matt 0081- Glossy
Jasmin 0072 - Matt
Oyster White 1213 - Matt 1013 - Gloss
Titane White Aluminium 0335 9206 - Matt 9006 - Glossy
Titane Grey Aluminium 0335 9207 - Matt 9007 - Glossy
Anthracite Grey Aluminium 0346 9207 - Matt 9007 - Glossy
Volcanic Anthracite 0336 0346
Volcanic 0336
Grey White 9202 - Matt 9002 - Glossy
Chinchilla 0064 - Matt
Manhattan 0277 - Mat 0077 - Glossy
Natura 0235 - Matt 0035 - Glossy
Bahama 0254 - Matt 0054 - Glossy
Traffic Anthracite Black Grey 9217 7216 - Matt 9017 7016 -- Glossy Glossy
Traffic Black Jet Black 9217 9205 - Matt 9017 9005 -- Glossy Glossy
Jet Black Matt Black 9205 - Matt Matt 0557 9005 - Glossy
BlackBlack Quartz Matt 0550 - Matt 0557
Black Quartz 0550
Petal 0510 - Glossy
Sand Quartz 0522
Beige Quartz 0523
Caramel Quartz 0511
Terracotta Quartz 0512
Gold Look 0514
Brown Quartz 0529
Dark Brown 0847 - Matt
Chocolate Brown 8217 - Matt 8017 - Glossy
Tonic Tonic
Traffic LemonYellow 1223 0515 - Matt Glossy 1023 - Glossy
Traffic OrangeYellow Quartz 1223 0528 - Matt 1023 - Glossy
Flame Red Orange Quartz 3200 0528 - Matt 3000 - Glossy
FlameRed Red Ruby 3200 - Matt 3203 3000 - Glossy 3003
Ruby Red 3203 - Matt 3003 - Glossy
Standard Standard
Surfaces Surfaces
Mauve Violet 0517 - Glossy 0518
Violet Strawberry 0518 3770 - Glossy Matt 3470 - Glossy
Dark Purple Strawberry 0848 - Matt 3770 Matt 3470 - Glossy
Amethyst Quartz Dark Purple 0516 - Matt 0848
Amethyst Quartz 0516
Traffic White 9216 - Matt (Incurs +25% colour surcharge) 9016 - Glossy
Inox Chrome 0008
Chrome Steel Stainless 0008 available for Only stainless steel radiators
Technoline (Clear) 0325*
Technoline (Clear) Bare-metal lacquer glossy finish 0325. Only available for Charleston range White Matt excluding NZ-030-100. RAL 9016 on Information manufacturersâ&#x20AC;&#x2122; marks see page 58.
Black-silver hammered finish 0422. Only available for Charleston range Volcanic 0336
Copper-black hammered finish 0421. Only available for Charleston range
Planus Surface
Spring Lichen Green 0846 8723 -- Matt Matt 8423 - Glossy
Spring Pacific Green Blue 0846 0519 - Matt
HorizonBlue Blue Pacific 0520 - Matt Glossy 0519
PrussianBlue Blue Horizon 0555 - Glossy 0520
Prussian Blue 0555 - Glossy Grey Aluminium 9207 - Matt 9007 - Glossy
Some colours/surface finishes are only available for selected products.
Grey Aluminium with Serigrafie RAL 9007
Deviations are possible (shade and shine) due to the different manufacturing techniques used for the original colours. RAL and NCS are manufacturer designations.
nishes are onlySome available colours/surface for selectedfinishes products. are only available for selected products.
This colour chart only represents the range of Zehnder colours available. It is not representative of the actual colour finish.
Please for a manufacturing colour from which to confirm your before placing order. (shade and shine) Deviations due to ask are the possible different (shade andchart shine) techniques due to the used different for the manufacturing original colours. techniques RAL selection and used NCS for arethe manufacturer original colours. designations. RALyour and NCS are manufacturer designations. 62 2
January 2019 Colour System
633
General Information
Notes
Heat Loss Calculator
Frequently Asked Questions
This easy-to-use heat calculator can work out the heat requirements for your room. Stage 1 Take the room dimensions in metres Width
m
Length
m
Height
m
cubic metres
calculate the volume (W x L x H) =
Stage 2 Heating requirements per room type volume
Living Room / Dining Room / Bathroom multiply volume as calculated in Stage 1 by 50 = Bedroom
multiply volume as calculated in Stage 1 by 40 = Kitchen / Hallway
Watts required
volume Watts required
volume
multiply volume as calculated in Stage 1 by 30 =
Watts required
Why is it important with some of the models that the flow is in a specific connection position? Some of the design radiators have baffles inside the water-carrying tubes to divert the water flow around the whole radiator to maximize efficiency. Check the installation instructions to see if this applies to the radiator before it is installed.
Stage 3 Other factors for consideration Is the property exposed? a Does the room have large areas of glazing? b Are the windows double glazed? c If factor ‘a’ applies, increase the Watts required at Stage 2 by 15% If factor ‘b’ applies, increase the Watts required at Stage 2 by 20% If factor ‘c’ applies, decrease the Watts required at Stage 2 by 10% If factor ‘a’ and ‘b’ apply, increase the Watts required at Stage 2 by 35% If factor ‘a’ and ‘c’ apply, increase the Watts required at Stage 2 by 5% If factor ‘b’ and ‘c’ apply, increase the Watts required at Stage 2 by 10% If factor ‘a’, ‘b’ and ‘c’ apply, increase the Watts required at Stage 2 by 25% Please note that this calculator is provided as a guide only. To convert Watts to BTUs, multiply by 3.412. For an approximate conversion from ∆T50°C to ∆T60°C, multiply the ∆T50°C output by 1.2.
Terms and Conditions of Trading
A complete copy of the company’s terms and conditions of trading are available on our website www.zehnder.co.uk In addition to the Terms and Conditions, please note the following: n All delivery times quoted are estimates only. Prices quoted include free delivery to the UK mainland for radiators and towel rails. Orders for valves, fans, elements and accessories with a net order value under £100 are subject to a processing charge of £10 + VAT n Returned goods for credit will only be accepted by prior arrangement (confirmed in writing), within 8 weeks of the date of despatch, where the goods are part of our stock range and where the goods are as fit for sale on their return as they were on delivery. If goods have been fitted this is deemed as acceptance of their quality. We cannot accept the return of non-stock goods. n Damaged products are to be reported to us within 3 days of delivery. Zehnder cannot be held responsible for any damage after onward delivery. Faulty products are to be reported to us as soon as possible. If the items have been installed, you are in acceptance of it’s condition and Zehnder reserve the right to refuse credit. n You are responsible for ensuring the suitability, conformity and interoperability of the goods or indicative system design suggestions provided by us with your heating system and your design requirements. It is important that you undertake such verification with an appropriately qualified expert third party n Where a radiator is returned as no longer required and an alternative radiator is not ordered a 25% restocking fee plus a £10 administration fee will be charged (unless the goods were defective when delivered). If a radiator is no longer required but an alternative radiator is ordered, either a restocking fee of £25 or 25% of the value (whichever is the lower) will be charged, but the administration fee will be waived. n We warrant the goods for a period of 5 years for steel radiators, 10 years for stainless steel and aluminium radiators, 2 years for radiator electrical componentry and 3 years for extractor fans, from the date of delivery. The warranty is subject to correct installation to current standards/water treatments and use. n Radiators with steel components (other than stainless steel) must not be installed on a domestic hot water circuit. If a stainless steel or brass product is to be installed on the domestic hot water circuit, a check should be made with the local water authority to ensure that dezincification is not a common occurrence. n Artificially softened water should not be used to fill radiators. For FAQ radiator/water-related information, visit www.fernox.com. n All measurements given in this brochure are nominal dimensions only. n All brochures, catalogues and other promotional materials are to be treated as illustrative only. Their contents form no part of any contract between us and you should not rely on them in entering into any contract with us. Any typographical, clerical or other error or omission in any literature, quotation, price list, or other document issued by us will be subject to correction without liability being incurred by us. Bathroom Zones The diagram below shows a bathroom divided into four clear zones: 0, 1, 2 and outside zones. Please note, the diagram is only a guide and is NOT to scale. Please refer to I.E.E Wiring Regulations (BS 7671:2008) for detailed information. Zone 0: Inside the bath Zone 1: Area above bath / shower tray to a height of 2.25m. Minimum rating of IPX4 should be used unless water spray will be present. In this case, a rating of IPX5 should be used. Zone 2: Area stretching 0.6m from zone 1. Minimum rating of IPX4 should be used here. Outside Zones: No water spray is likely to be used here, therefore, no IP rating is required. IP Rating: “X” denotes level of security against dust particles. Second digit denotes level of “watertightness”. IPX5: Protected against low pressure water jets IPX4: Protected against splashing water 64
Space under bath is Zone 1, if readily accessible
N.B: The above diagram is only a guide and not to scale. Please refer to I.E.E. Wiring Regulations (BS 7671 : 2008).
What is an inhibitor and why should it be used in a central heating system? An inhibitor is a chemical mix that should be added to the central heating system water to prevent corrosion and to prolong the life of the system. When new or additional radiators are being installed, the system should be drained, cleaned and flushed in accordance with BS7593 and a good quality chemical water treatment inhibitor should be added to the heating system. Can steel and aluminium radiators be put on the same system? Yes, as long as an inhibitor for mixed metal systems is used. In reality, most systems are already mixed metal, as many have aluminium heat exchangers in the boiler, plus copper pipes and steel radiators already installed. Why is it important to use dual energy installations correctly? Simultaneous use of the electrical element and the central heating system should be avoided as this will shorten the life of the element and invalidate the warranty. Correct use is as follows: In summer when the central heating is switched off, vent the radiator to ensure there is no air present, then close the flow valve (only) and activate the immersion heater. In winter, de-activate the immersion heater and open the flow valve. What is the difference between outputs listed at ΔT60°C and ΔT50°C? ΔT60°C allows for older boiler systems, whilst ΔT50°C is the new European testing standard for modern boilers, such as condensing boilers, which have lower flow and return temperatures. Therefore, to avoid radiators being incorrectly sized, it is important to know the system’s temperatures and take them into consideration.
January 2019
65
Notes
66
January 2019
67
Š Zehnder (retail) - A Division of Zehnder Group UK Ltd. Modification rights reserved. V12019.1 Zehnder Group UK Ltd Concept House . Watchmoor Point . Camberley . Surrey . GU15 3AD . Registered in England: 2296696 T: +44 (0) 1276 605800 F: +44 (0) 1276 24058 For placing an order . orders@zehnder.co.uk For general enquiries . retailsales@zehnder.co.uk aftersales@zehnder.co.uk quotes@zehnder.co.uk www.zehnder.co.uk