Zehnder Radiators and Towel Warmers Profession Brochure

Page 1

Decorative Radiators

Comfortable Indoor Ventilation

Heating & Cooling Ceiling Systems

Always the best climate for

RADIATORS AND TOWEL WARMERS For central heating, electric and dual energy installations

Zehnder Professional Catalogue January 2019 v1

Clean Air Solutions


CONTENTS

Bathrooms Zehnder’s Bathroom towel radiators range; from the simply practical to our affordable designer range, suitable for central heating, electric and dual energy installations.

Page 6

Zehnder Aura

Page 14

Page 8

Zehnder Aura electric

Page 16

Page 10

Zehnder Aura Bow

Page 18

Page 12

TIP: All towel rails should be wiped dry as those in a damp or condensation laden atmosphere may suffer from superficial corrosion if not dried regularly. If this is the case, using a industry recommended chrome polish will remove early stages of this and restore the surface finish.

A carefully selected range of quality products at very competitive prices A wide choice of stock sizes available for immediate delivery 5 year warranty for all centrally heated steel products 10 year warranty for all centrally heated aluminium and stainless steel products

Zehnder Klaro

Page 20

All products supplied with brackets and air vents as standard Made-to-measure options included or available on request

Zehnder Muralis

Zehnder Stellar

Zehnder Stellar Spa

A comprehensive colour range available for selected products

Zehnder Zeta

Heat loss calculator to estimate the heat requirements for your room - see page 64

Living Zehnder’s comprehensive range of central heating and electric radiators for living areas, provides a complete heating solution for the home at very competitive prices.

Page 22

Page 26

Page 28

Page 30

Page 32

Expert technical back-up available Full technical details of all products available on our website: www.prorange.zehnder.co.uk

Zehnder Charleston

Page 34

Zehnder Charleston m2m

Page 36

Zehnder Kleo

Zehnder Lyta-S

Zehnder Lyta-T

All outputs tested to the European standard EN442 Symbol Key

Page 38

Page 40

Page 40

Central heating Suitable for domestic water Electric radiators

NEW

Zehnder Roda

Dual energy radiators

NEW

Zehnder Roda m2m

Zehnder Stana

Zehnder Alura

22

Zehnder Charleston Electric and Electric Plinth

m2m radiators

10 10

55

Colour

Extractor Fans, Accessories & Technical

2 5 10 10 2 2235 5510 10 DAY DAY

Page 42

Page 48

Page 49

DAY DAY

3-5 3-5

DAY DAY

5-7 5-7

14 14

Years warranty

DAY DAY

DAY

WEEKS WEEKS DAY

3-5 3-5 5-7

3-5

DAY

3-5

WEEKS WEEKS DAY

DAY DAY DAY

3-5 3-5 5-7

4-6 4-6 14

DAY DAY DAY

5-7 5-7 14

DAY WEEKS

17 3-5

Extractor fans

Valves, dual energy Technical and electric products specifications

WEEKS

WEEKS

DAY DAY

Delivery 1414 weeks applies to non-stocked items

DAY

DAY DAY WEEKS WEEKS

17 17 3-5 3-5

All products 20 4-6 are CE approved.

WEEKS

3-5

20 20 *applies to stock items only

DAY WEEKS

17 3-5 3-5

Delivery working days DAY DAY

WEEKS WEEKSWEEKS

DAY WEEKS WEEKS

DAY DAY

All central heating 20 products 2020 certified to EN442. 4-6 4-6 3-5 3-5 4-6

STOCK: All products listed in bold black type are stocked items.

January 2019

3


ECO DESIGN

ECO DESIGN

Eco Design Regulations for electric heating Since 1st January 2018, all electric local space heaters manufactured for sale in the EU must comply with a minimum efficiency standard under Lot 20 of the Energy Efficiency Directive. This is one of the biggest changes the electric heating industry has experienced in decades.

Towel warmers (less than 250W) are not included in the scope of the directive.

What exactly is Lot 20?

What are the benefits of this Directive?

The directive comes from: The European Ecodesign Directive (2009/125/EC)

Overall, the aim of the directive is Energy Saving. It ensures more efficient electric radiators with following benefits;

“The aim of this legislation is to rule out inefficient technologies and reduce the energy used by the products that heat our homes, helping to achieve our national carbon reduction targets.” The Regulation will affect; Storage heaters Direct acting heaters Portable heaters Radiant heaters Electric fires

How does this change impact products? To comply with the Lot 20 Regulations, all local space heaters have to meet a minimum efficiency rating that is measured as a percentage. Electric radiators, infrared heaters and panel heaters are all classed as ‘fixed electric local space heaters’, and they must have at least a 38% efficiency rating if they have a nominal heat output above 250W.

As a result of these efficiency targets, products must include energy saving features such as better controls for end users.

Cost Savings to the end user as the radiator will perform more efficiently in the home arbon Emission Reduction helping protect our environment for C the future Improved customisation and control for end users as a result of more interactive and programmable capabilities in the products to help reduce unnecessary energy wastage

What about Zehnder electric products? As part of the changes, new features that offer benefit to end user to maximise efficiency and control will be included; ow energy consumption when on stand-by L Programmable operation (weekly) Open window detection Presence Detection Electric heating control details are included on each product page.

Zehnder Radio Frequency Control As part of the Eco Design Directive improvements, a Radio Frequency control is now available with a number of products offering; ireless control of radiator to end user - range of up to 30 W metres in open space and up to 10 metres between rooms (one wall) choice of pre-set programmes - working from a set A 'comfort temperature' by the end user

Showing wireless radio frequency pad for simple control and programming by end user.

4

ull customisation of weekly programme e.g. choose comfort F temperature and time during the day to work between eco and comfort settings.

PBECZ-120-50/F CHROME 0008

January 2019

5


AURA

TOWEL RAIL Central Heating Model STOCK listed in black

Height mm

Width mm

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Max. Immersion rating Watts*

RRP (ex VAT)

287/979 358/1221 418/1426 512/1747 598/2040 631/2153 740/2525 788/2689 925/3156 287/979 358/1221 418/1426 427/1457 512/1747 598/2040 788/2689 925/3156 151/515 186/635 230/785 271/925 287/979 278/949 330/1126 390/1331 346/1181 407/1389 481/1641 432/1473 513/1750 607/2071 741/2527

200 200 300 300 400 400 500/400 500/400 600 200 200 300 300 300 400 500/400 600 100/n/a 100/n/a 150/120 150/120 200 200 200 300 300 300 300 300 300 400 500

£90 £96 £101 £114 £119 £134 £138 £145 £153 £113 £120 £126 £136 £143 £149 £181 £191 £89 £108 £112 £118 £126 £135 £138 £141 £161 £167 £174 £178 £184 £190 £200

Zehnder Aura 22mm tube

NEW NEW NEW NEW NEW NEW NEW NEW

PBZ-080-040 775 400 PBZ-080-050 775 500 PBZ-080-060 775 600 PBZ-120-050 1217 500 PBZ-120-060 1217 600 PBZ-150-050 1469 500 PBZ-150-060 1469 600 PBZ-180-050 1856 500 PBZ-180-060 1856 600 PBZ-080-040-0346 775 400 PBZ-080-050-0346 775 500 PBZ-080-060-0346 775 600 PBZ-120-040-0346 1217 400 PBZ-120-050-0346 1217 500 PBZ-120-060-0346 1217 600 PBZ-180-050-0346 1856 500 PBZ-180-060-0346 1856 600 PBCZ-060-040 607 400 PBCZ-080-040 775 400 PBCZ-080-050 775 500 PBCZ-080-060 775 600 PBCZ-100-050 1027 500 PBCZ-120-040 1217 400 PBCZ-120-050 1217 500 PBCZ-120-060 1217 600 PBCZ-150-040 1469 400 PBCZ-150-050 1469 500 PBCZ-150-060 1469 600 PBCZ-180-040 1856 400 PBCZ-180-050 1856 500 PBCZ-180-060 1856 600 PBCZ-180-075 1856 750 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW

white white white white white white white white white Anthracite Anthracite Anthracite Anthracite Anthracite Anthracite Anthracite Anthracite chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome chrome

2 5 10 Zehnder Aura 2

DAY

3-5

5

DAY

5-7

10

DAY

14

DAY WEEKS

17 3-5

A classic ladder-style towel warmer in sizes to suit all popular heating sizes and types of décor. Easily connected to an existing central heating system, or fitted with a dual energy electric element for summer use. (See page 48 for details). DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details Optional wall brackets

60

110-120

Model 926511 926518

Set of 4 replacement brackets in white for PBZ models Set of 4 replacement brackets in chrome for PBCZ models

W-44

RRP (ex VAT) £27 £27

* air vent Width excludes air vent F = flow R = return Tube: Horizontal \ 22mm Tube: Vertical D Profile 30 x 40mm All dimensions in mm

W-44

Suitable for dual energy installations. See page 48 for details.

PBZ-080 PBCZ-080

The complete 6

PBZ-120 PBCZ-120

PBZ-150 PBCZ-150

compliant technical specifications can be found between pages 49-57.

PBZ-180 PBCZ-180

Zehnder recommends VAL-SET-1-CR. For more information see page 48. PBCZ-150-050-0346 ANTHRACITE 0346

January 2019

7


AURA ELECTRIC Electric Heating Model

TOWEL RAIL Height mm

Width mm

Finish

Simple electric immersion heater Class II IPX4, Zones 1 and 2

RRP (ex VAT)

821 941 1261 1261 1901

400 500 500 600 500

chrome chrome chrome chrome chrome

150 200 300 400 500

£234 £239 £281 £285 £350

Zehnder Aura Electric 22mm tube PBECZ-080-40/F PBECZ-090-50/F PBECZ-120-50/F PBECZ-120-60/F PBECZ-180-50/F

Zehnder 2 5 10 Aura Electric DAY

3-5

Electric Heating Model

Height mm

Width mm

Finish

Adjustable thermostatic controller Class II IPX4 with 7 day programmer

RRP (ex VAT)

5

DAY

14

10

17 3-5

A classic yet stylish chrome electric towel radiator which is perfect for modern homes. Choose from a factory-fitted simple immersion heater or an adjustable thermostatic controller. WEEKS

3-5

DAY WEEKS

3-5 4-6

DAY DAY

5-7 20

DAY

14

DAY WEEKS

17 3-5

1287 1287

500 600

chrome chrome

300 400

£327 £330

Height measurements of electric models include electric heaters Optional wall brackets Model 926588

DAY

5-7

DAY WEEKS

Zehnder Aura Electric 22mm tube PBECZ-120-50/WF PBECZ-120-60/WF

2

Set of 4 replacement brackets in chrome for PBECZ models

RRP (ex VAT) £27

WEEKS

3-5

WEEKS

4-6

DAY

20

Tube: Horizontal \ 22mm Tube: Vertical D Profile 30 x 40mm All dimensions in mm

Simple Immersion heater

Adjustable thermostatic controller. Eco Design compliant with only the adjustable thermostatic controller 8

PBECZ-120-50/F CHROME 0008

January 2019

9


AURA BOW

TOWEL RAIL

Central Heating Model STOCK listed in black

Height mm

Width mm

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Max. Immersion rating Watts*

RRP (ex VAT)

494 595 494 595 494 595 494 595 494 595 494 595

white white white white white white chrome chrome chrome chrome chrome chrome

358/1221 418/1426 512/1747 598/2040 788/2689 925/3156 230/785 271/925 330/1126 390/1331 513/1750 607/2071

200 300 300 400 500/400 600 150/120 150/120 200 300 300 400

£101 £104 £123 £126 £156 £163 £115 £120 £141 £145 £193 £200

Zehnder Aura Bow 22mm tube PBTZ-080-050 775 PBTZ-080-060 775 PBTZ-120-050 1217 PBTZ-120-060 1217 PBTZ-180-050 1856 PBTZ-180-060 1856 PBTCZ-080-050 775 PBTCZ-080-060 775 PBTCZ-120-050 1217 PBTCZ-120-060 1217 PBTCZ-180-050 1856 PBTCZ-180-060 1856 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW

5

DAY

5-7

10

DAY

14

DAY WEEKS

17 3-5

A stylish, modern curved ladder radiator for warming towels. Suitable for connection to an existing central heating system or fitted with a dual energy electric element for summer usage. (See page 48 for details). DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

WEEKS

WEEKS

4-6

DAY

20

55-65

60

55-65

DAY

3-5

* air vent Width excludes air vent F = flow R = return Tube: Horizontal \ 22mm Tube: Vertical D Profile 30 x 40mm All dimensions in mm

60

110-120

W

W

2

3-5

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details

W

Zehnder 5 10 Aura 2Bow

W W-44

W-44

PBTZ-080 PBTCZ-080

PBTZ-080 PBTZ-120 PBTCZ-080 PBTCZ-120

PBZ-080 PBCZ-080

The complete 10

PBTZ-120 PBTZ-150 PBTCZ-120 PBTCZ-150

PBTZ-150 PBTZ-180 PBTCZ-150 PBTCZ-180

PBZ-120 PBCZ-120

compliant technical specifications can be found between pages 49 and 57.

PBZ-150 PBCZ-150

PBTZ-180 PBTCZ-180

Suitable for dual energy installations. See page 48 for details.

PBZ-180 PBCZ-180

Zehnder recommends VAL-SET-1-CR. For more information see page 48. PBTCZ-080-060 CHROME 0008

January 2019

11


KLARO Central Heating Model STOCK listed in black

TOWEL RAIL Height mm

Width mm

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Max. Immersion rating Watts*

RRP (ex VAT)

Zehnder Klaro ZSL-080-045-0336 ZSL-120-050-0336 ZSL-120-060-0336 ZSL-150-050-0336 ZSL-150-060-0336 ZSL-170-050-0336 ZSL-170-060-0336 ZSL-080-045-0523 ZSL-120-050-0523 ZSL-120-060-0523 ZSL-150-050-0523 ZSL-150-060-0523 ZSL-170-050-0523 ZSL-170-060-0523 ZSL-080-045-0529

748 1148 1148 1466 1466 1708 1708 748 1148 1148 1466 1466 1708 1708 748

450 500 600 500 600 500 600 450 500 600 500 600 500 600 450

volcanic volcanic volcanic volcanic volcanic volcanic volcanic beige quartz beige quartz beige quartz beige quartz beige quartz beige quartz beige quartz brown quartz

354/1208 571/1948 670/2286 716/2443 839/2863 824/2811 966/3296 354/1208 571/1948 670/2286 716/2443 839/2863 824/2811 966/3296 354/1208

200 400 500/400 500/400 500/400 500/400 600 200 400 500/400 500/400 500/400 500/400 600 200

£155 £188 £203 £233 £245 £261 £268 £155 £188 £203 £233 £245 £261 £268 £155

ZSL-120-050-0529

1148

500

brown quartz

571/1948

400

£188

ZSL-120-060-0529 1148 600 brown quartz 670/2286 500/400 ZSL-150-050-0529 1466 500 brown quartz 716/2443 500/400 ZSL-150-060-0529 1466 600 brown quartz 839/2863 500/400 ZSL-170-050-0529 1708 500 brown quartz 824/2811 500/400 ZSL-170-060-0529 1708 600 brown quartz 966/3296 600 An immersion heater for dual energy use can only be fitted in the header tube without the insert tube. Max. working pressure: 11.5 bar *Rating for simple immersion/CTEC or CTEW

£203 £233 £245 £261 £268

2 5 10 Zehnder Klaro 2

DAY

3-5

5

DAY

5-7

10

DAY

14

DAY WEEKS

17 3-5

A popular towel drying ladder rail available from stock in three contemporary colours, giving approximately 30% more output than chrome plus greater originality in bathroom design. It can be fitted with an immersion heater for use when the central heating system is not in use. (See page 48 for details). DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 16 working days.

94

94

*1/2” air vent Air vent can be moved either side depending on flow position. Width excludes air vent F = flow R = return Tube: Horizontal \ 23mm Tube: Vertical \ 38mm All dimensions in mm

ZSL-120

ZSL-150

ZSL-170

ZSL-080

The complete 12

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-1-CR. For more information see page 48.

ZSL-120-050-0336 VOLCANIC 0336

January 2019

13


MURALIS

TOWEL RAIL

Central Heating Model STOCK listed in black

Height mm

Width mm

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Finish

Max. Immersion rating Watts*

RRP (ex VAT)

200 200 300 300 400 150/120 200 200 200 300

£200 £233 £262 £288 £318 £209 £237 £285 £332 £381

Zehnder Muralis MUR-080-050-0346 800 500 anthracite MUR-100-050-0346 1000 500 anthracite MUR-120-050-0346 1200 500 anthracite MUR-140-050-0346 1400 500 anthracite MUR-160-050-0346 1600 500 anthracite MURC-080-050 800 500 chrome MURC-100-050 1000 500 chrome MURC-120-050 1200 500 chrome MURC-140-050 1400 500 chrome MURC-160-050 1600 500 chrome * Rating for simple immersion/CTEC or CTEW Max. working pressure: 4 bar

306/1044 384/1310 461/1573 537/1832 612/2088 197/672 249/850 301/1027 346/1181 391/1334

5

DAY

5-7

10

DAY

14

DAY WEEKS

17 3-5

A modern, attractive, towel radiator with evenly spaced square tubes, the Zehnder Muralis is suitable for fitting with a dual energy electric immersion heater for use when the central heating system is not operating. (See page 48 for details). DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

WEEKS

3-5

WEEKS

4-6

DAY

20

* air vent Width excludes air vent F = flow R = return Tube: Horizontal 23 x 23mm Tube: Vertical 30 x 30mm All dimensions in mm

H

H

H

H H

DAY

3-5

DAY WEEKS

H H

2

10

17 3-5

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details

H

Zehnder 2 5 Muralis

H

H

H

H MUR-100 MUR-100 MURC-100 MURC-100

MUR-120 MUR-120 MURC-120 MURC-120

MUR-100 MUR-100 MURC-100 MURC-100

MUR-080 MUR-080 MURC-080 MURC-080

MUR-120 MUR-120 MURC-120 MURC-120

MUR-080 MUR-080 MURC-080 MURC-080 H H

H

H H

H

H

H

MURC-100-050 CHROME 0008 MUR-140 MUR-140 MURC-140 MURC-140

MUR-140 MUR-140 MURC-140 MURC-140

The complete 14

compliant technical specifications can be found between pages 49 and 57.

MUR-160 MUR-160 MURC-160 MURC-160

MUR-160 MUR-160 MURC-160 MURC-160

Zehnder recommends VAL-SET-1-CR. For more information see page 48. MUR-100-050-0346 ANTHRACITE 0346

January 2019

15


STELLAR

STAINLESS STEEL Height mm

Width mm

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Max. Immersion rating Watts*

DAY

100/n/a 200 100/n/a 150/120 150/120 150/120 150/120 200 300 300 300 400 150 300 150 200

£244 £438 £245 £294 £345 £349 £399 £465 £616 £707 £711 £814 £244 £438 £245 £294

STNI-080-060-CF

788

600

s/steel painted

395/1348

200

£345

s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted

353/1204 482/1645 600/2047 591/2016 736/2511 672/2293 838/2859

200 300 400 400 500 500 600

£349 £399 £465 £616 £707 £711 £814

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details

5

DAY

3-5

DAY WEEKS

DAY WEEKS

4-6 14

DAY

20

DAY WEEKS

Simple, elegant and contemporary, the stainless steel Zehnder Stellar is the ideal solution for minimalist bathroom designs and wet rooms. DAY

DAY WEEKS

3-5

5-7 3-5

DAY WEEKS

144-6

DAY

20

DAY WEEKS

17 3-5

WEEKS

WEEKS

3-5

EE

4-6

DAY

20

L • S TA I N L E S

10

Year

Warranty

STNI-120-045 STAINLESS STEEL FINISH

*1/2” air vent Height excludes air vent F = flow R = return H = height W = width Tube: Horizontal \ 23mm Tube: Vertical 30x30mm All dimensions in mm

Width-30

10

3-55-7

DAY WEEKS

21 3-5

17 3-5

STNI-120-030-CF 1220 300 STNI-120-045-CFWidth-30 1220 450 STNI-120-060-CFWidth-30 1220 600 STNI-150-045-CF 1508 450 STNI-150-060-CF 1508 600 STNI-170-045-CF 1724 450 STNI-170-060-CF 1724 600 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW

2

INLESS S T S TA

159/541 284/970 159/541 206/702 253/863 242/826 316/1078 391/1334 389/1327 491/1675 452/1542 545/1860 233/795 430/1467 232/792 317/1082

STEEL

s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel painted s/steel painted s/steel painted s/steel painted

LESS

450 1000 300 450 600 300 450 600 450 600 450 600 450 1000 300 450

DAY

14

T E E L • S TA

572 572 788 788 788 1220 1220 1220 1508 1508 1724 1724 572 572 788 788

DAY

5-7

SS

STNI-060-045 STNI-060-100 STNI-080-030 STNI-080-045 STNI-080-060 STNI-120-030 STNI-120-045 STNI-120-060 STNI-150-045 STNI-150-060 STNI-170-045 STNI-170-060 STNI-060-045-CF STNI-060-100-CF STNI-080-030-CF STNI-080-045-CF

10

5

2 5 10 Zehnder Stellar 3-5

Zehnder Stellar

No price surcharge for colour finishes. Applies to all products in grey

2

RRP (ex VAT)

IN

Central Heating Model STOCK listed in black

STNI-080-030 STAINLESS STEEL FINISH

Width-30

Suitable for dual energy installations. See page 48 for details

Width-30

Colour finish: Standard colours from the Zehnder Colour Chart at no extra cost. Delivery of colour finish and non-stock products: 4-6 weeks. The complete 16

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-1-CR. For more information see page 48. STNI-060-100 STAINLESS STEEL FINISH

January 2019

17


STELLAR SPA

STAINLESS STEEL RRP (ex VAT)

161/549 272/928 171/583 220/751 243/829 240/819 309/1054 379/1293 361/1232 448/1529 434/1481 517/1764 219/747 394/1344 218/744 294/1003 363/1239 332/1133 448/1529 554/1890 556/1897 687/2344 640/2184 791/2699

100 150/120 100 100 150/120 150/120 150/120 200 300 300 200 300 150 200 150 200 200 200 300 300 300 400 400 500

£226 £406 £227 £272 £319 £323 £370 £431 £570 £655 £658 £754 £226 £406 £227 £272 £319 £323 £370 £431 £570 £655 £658 £754

Zehnder Stellar Spa s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel finish s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted s/steel painted

DAY

3-5

2

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details

5

DAY

3-5

10

DAY WEEKS

3-5 5-7

10

5

10

DAY

5-7

DAY

14

DAY WEEKS

21 3-5 DAY WEEKS

4-6 14

DAY

20

DAY WEEKS

17 3-5

Contemporary in design in stainless steel to suit the latest lifestyle trends. Suitable for dual energy installation for year-long comfort. DAY

DAY WEEKS

3-5

5-7 3-5

DAY WEEKS

144-6

DAY

20

DAY WEEKS

17 3-5

WEEKS

WEEKS

3-5

EE

4-6

DAY

20

L • S TA I N L E S

10

Year

Warranty •

No price surcharge for colour finishes. Applies to all products in grey

STGI-060-045 572 450 STGI-060-100 572 1000 STGI-080-030 788 300 STGI-080-045 788 450 STGI-080-060 788 600 STGI-120-030 1220 300 STGI-120-045 1220 450 STGI-120-060 1220 600 STGI-150-045 1508 450 STGI-150-060 1508 600 STGI-170-045 1724 450 STGI-170-060 1724 600 STGI-060-045-CF 572 450 STGI-060-100-CF 572 1000 STGI-080-030-CF 788 300 STGI-080-045-CF 788 450 STGI-080-060-CF 788 600 STGI-120-030-CF 1220 300 STGI-120-045-CF 1220 450 STGI-120-060-CF 1220 600 STGI-150-045-CF 1508 450 STGI-150-060-CF 1508 600 STGI-170-045-CF 1724 450 STGI-170-060-CF 1724 600 Max. working pressure: 10 bar *Rating for simple immersion/CTEC or CTEW

Zehnder 2 2 5 Stellar Spa

T E E L • S TA

Max. Immersion rating Watts*

SS

Output ∆T=50K Watts/Btu All outputs certified to EN 442

INLESS S T S TA

Finish

STEEL

Width mm

LESS

Height mm

IN

Central Heating Model STOCK listed in black

*1/2” air vent Height excludes air vent F = flow R = return H = height W = width Tube: Horizontal \ 23mm Tube: Vertical 30x30mm All dimensions in mm

STGI 080-030 STAINLESS STEEL FINISH

Suitable for dual energy installations. See page 48 for details

STGI-170-045 STAINLESS STEEL FINISH

Colour finish: Standard colours from the Zehnder Colour Chart at no extra cost. Delivery of colour finish and non-stock products: 4-6 weeks. The complete 18

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-1-CR. For more information see page 48.

STGI-060-100 STAINLESS STEEL FINISH

January 2019

19


TOWEL RAIL

ZETA Central Heating Model STOCK listed in black

Height mm

Width mm

Pipe centres mm

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Max. Immersion rating Watts

RRP (ex VAT)

324/1105 476/1624 647/2208 342/1105 476/1624 647/2208 203/689 235/792 302/1034 350/1204 395/1344 457/1559

200 300 400 200 300 400 200 200 300 400 400 400

£148 £193 £270 £185 £243 £339 £201 £239 £270 £317 £375 £442

Zehnder Zeta PQ6-080-050 800 PQ6-120-050 1200 PQ6-160-050 1600 PQ6-080-050-0346 800 PQ6-120-050-0346 1200 PQ6-160-050-0346 1600 PQ6C-080-050 800 PQ6C-080-060 800 PQ6C-120-050 1200 PQ6C-120-060 1200 PQ6C-160-050 1600 PQ6C-160-060 1600 Max. working pressure: 4 bar

500 500 500 500 500 500 500 600 500 600 500 600

468 468 468 468 468 468 468 568 468 568 468 568

white white white anthracite anthracite anthracite chrome chrome chrome chrome chrome chrome

Dual Energy: Self Fit - Additional cost to Central Heating model prices see page 48 for details

2 5 10 Zehnder Zeta 2

DAY

3-5

5

DAY

5-7

10

DAY

14

DAY WEEKS

17 3-5

A popular variation of steel ladder rail suitable for installation on an existing central heating system. It is ideally suited for fitting with a dual energy electric immersion heater for use when the central heating is not in operation. (See page 48 for details). DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

* air vent Width excludes air vent F = flow R = return Tube: Horizontal oval tube 60 x 10mm Tube: Vertical \ 32mm All dimensions in mm

W W-32

W

W

H

H

900

H

CHROME 0008

PQ6-080 PQ6C-080

PQ6-120 PQ6C-120 PQ6-160 PQ6C-160

TRAFFIC WHITE 9016

The complete 20

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-1-CR. For more information see page 48. PQ6-120-050-0346 ANTHRACITE 0346

January 2019

21


CHARLESTON

MULTI-COLUMN

Central Heating Model STOCK listed in black

Height mm

Width mm

Overall Projection

Output ∆T=50K Watts/Btu All outputs certified to EN 442

No. of sections

RRP (ex VAT)

Zehnder Charleston Horizontal white RAL 9016 - 2 column 2050-10 2050-14 2050-18 2050-22 2050-26 2060-10 2060-14 2060-18 2060-22 2060-24 2060-28

492 492 492 492 492 592 592 592 592 592 592

486 670 854 1038 1222 486 670 854 1038 1130 1314

90 90 90 90 90 90 90 90 90 90 90

10 14 18 22 26 10 14 18 22 24 28

384/1310 538/1836 691/2358 845/2883 998/3405 453/1546 634/2163 815/2781 997/3402 1080/3685 1260/4284

£168 £235 £303 £370 £437 £174 £243 £313 £382 £417 £487

14 18 22 26 30 10 14 18 20 24 27 30 34 14 22 26

722/2463 929/3170 1135/3873 1342/4579 1548/5282 609/2078 853/2910 1096/3740 1220/4163 1464/4995 1645/5613 1827/6234 2071/7066 1040/3548 1635/5579 1932/6592

£279 £359 £439 £519 £599 £211 £295 £379 £421 £505 £569 £632 £716 £331 £520 £614

20 30 14 18 20 24 14 18 22 26

840/2866 1260/4299 1117/3811 1436/4900 1592/5459 1920/6551 1364/4654 1753/5981 2143/7312 2532/8639

£423 £635 £310 £399 £443 £532 £374 £481 £588 £695

500 670 500 854 500 1038 500 1222 500 1406 600 486 600 670 600 854 600 946 600 1130 600 1268 600 1406 2 Column 2 Column 600 1590 750 670 750 1038 750 1222

128 128 128 128 128 128 128 128 128 128 128 128 128 128 128 128

3-6 Column

2 Column

3-6 Column

3050-14 3050-18 3050-22 3050-26 3050-30 3060-10 3060-14 3060-18 3060-20 3060-24 3060-27 3060-30 3060-34 3075-14 3075-22 3075-26

2 Column

Zehnder Charleston Horizontal white RAL 9016 - 3 column

Zehnder 2 5 10 2 5 10 Charleston DAY

DAY

3-5

DAY

5-7

2

DAY

3-5

WEEKS

3-5

5

14 DAY

5-7

WEEKS

4-6

10

DAY DAY WEEKS

3-5 15 14

DAY DAY WEEKS

20 3-5 17

The Zehnder Charleston multicolumn design is equally at home in modern environments, and is available in a wide range of stocked horizontal and vertical models, or made-tomeasure, including angled and curved. Find out more about LaZer made on page 60. DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

Zehnder Charleston Horizontal white RAL 9016 - 4 column 4030-20 4030-30 4060-14 4060-18 4060-20 4060-24 4075-14 4075-18 4075-22 4075-26

300 300 600 600 600 600 750 750 750 750

946 1406 670 854 946 1130 670 854 1038 1222

164 164 164 164 164 164 164 164 164 164

2 Column

486 670 854 946 1130 1268 1406 1590

3-6 Column

2 Column

600 600 600 600 600 600 600 600

3-6 Column

Zehnder Charleston Horizontal - 3 column 3 Column 3anthracite Column 4 Column 4 Column 3060-10-0346 3060-14-0346 3060-18-0346 3060-20-0346 3060-24-0346 3060-27-0346 3060-30-0346 3060-34-0346

128 128 128 128 128 128 128 128

5 Column 5 Column

Technoline 0325. For more information please see page 58.

6 Column 6 Column

10 14 18 20 24 27 30 34

£243 £339 £436 £484 £581 £654 £727 £823

609/2078 853/2910 1096/3740 1220/4163 1464/4995 1645/5613 1827/6234 2071/7066

Black-silver hammered 0422

Model code breakdown: eg. 3060-34 = 3 (number of columns), 060 (600mm high), 34 (number of sections). 2 Column2 Column

Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks.

3 Column3 Column 2 Column

The complete

4 Column4 Column

5 Column5 Column

compliant technical specifications can be found between pages 49 and 57. 3 Column 3 Column

22

*1/2” air vent Width excludes air vent F = flow R = return H = height W = width Tube: Vertical \ 25mm All dimensions in mm Manufacturing tolerance of +/-0.6mm per section

3-6 Column

2 Column

Expect manufacturers marks on Charleston finishes. See page 60 for more information.

Adjustable Foot

6 Column6 Column

Don’t forget to use your Charleston radiator packaging to protect your new radiator whilst decorating - see the cardboard outer for details.

Cast Iron Foot

2050-18 TRAFFIC WHITE 9016

January 2019

23


CHARLESTON Central Heating Model STOCK listed in black

MULTI-COLUMN

Height mm

Width mm

Number of sections

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

RRP (ex VAT)

Zehnder Charleston vertical 2180-6 1792 302 6 white 2180-8 1792 394 8 white 2180-10 1792 486 10 white 2180-12 1792 578 12 white 3180-6 1800 302 6 white 3180-8 1800 394 8 white 3180-10 1800 486 10 white 2180-8-0346 1792 394 8 anthracite 2180-10-0346 1792 486 10 anthracite 2180-12-0346 1792 578 12 anthracite Model code breakdown: eg. 3180-8 - 3 (number of columns), 180 (180cm high) 8 (number of sections).

744/2539 992/3385 1240/4231 1488/5077 996/3398 1328/4531 1660/5664 992/3385 1240/4231 1488/5077

£249 £332 £414 £497 £341 £455 £568 £382 £476 £572

Zehnder 2 5 10 2 5 10 Charleston DAY

DAY

3-5

2

DAY

3-5

WEEKS

3-5

4 Column 4 Column

5

14

DAY

5-7

WEEKS

4-6

10

DAY DAY WEEKS

3-5 15 14

DAY DAY WEEKS

20 3-5 17

A timeless decorative radiator that suits modern or traditional settings, the multicolumn is available from stock in a RAL 9016 white finish and stylish Anthracite textured finish, or to order from a range of 50 other colours. Wall supports and air vents are included. Stylish support feet are available if required. Find out more about LaZer made on page 60. DAYWEEKS

3-53-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

WEEKS

3 Column 3 Column

DAY

5-7

5 Column 5 Column

6 Column 6 Column

*1/2” air vent Width excludes air vent F = flow R = return H = height W = width Tube: Vertical \ 25mm All dimensions in mm Manufacturing tolerance of +/-0.6mm per section

3 Column 3 Column

3-5

WEEKS

4-6

DAY

20

HORIZON BLUE 0520

You can use our Charleston packaging to protect your radiator whilst decorating. Instructions on the pack. Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The complete 24

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-2-CR. For more information see page 48. ANTHRACITE 0346

January 2019

25


CHARLESTON MADE TO MEASURE Nominal Model Output 50∆T Height code Watts/BTU mm

M2M MULTI-COLUMN

RRP white (ex VAT)

RRP colour (ex VAT)

Model Output 50∆T code Watts/BTU

RRP white (ex VAT)

RRP colour (ex VAT)

3 column

Zehnder Charleston - 2 column

Model Output 50∆T code Watts/BTU

RRP white (ex VAT)

RRP colour (ex VAT)

4 column

200

2019

14.5/49

£16.60

£20.75

3019

20.1/69

£19.67

£24.59

4019

28.4/97

£21.11

£26.39

260

2026

21.1/72

£16.62

£20.78

3026

27/92

£19.70

£24.63

4026

36.5/125

£21.14

£26.43

300

2030

24/81

£16.66

£20.83

3030

32/109

£19.72

£24.65

4030

42/143

£21.16

£26.45

342

2035

27.5/94

£16.68

£20.85

3035

37/126

£19.77

£24.71

4035

48.5/165

£21.55

£26.94

400

2040

31/106

£16.71

£20.89

3040

42/143

£19.82

£24.78

4040

55/187

£21.94

£27.43

450

2045

35/119

£16.76

£20.95

3045

47/160

£19.90

£24.88

4045

61/209

£22.00

£27.50

500

2050

38/131

£16.82

£21.03

3050

52/176

£19.95

£24.94

4050

68/232

£22.06

£27.58

550

2055

42/143

£17.33

£21.66

3055

56/192

£21.01

£26.26

4055

74/251

£22.12

£27.65

600

2060

45/155

£17.38

£21.73

3060

61/208

£21.06

£26.33

4060

80/272

£22.17

£27.71

750

2075

55/188

£20.17

£25.21

3075

74/254

£23.62

£29.53

4075

97/332

£26.74

£33.43

900

2090

64/218

£23.29

£29.11

3090

87/297

£27.85

£34.81

4090

114/389

£32.30

£40.38

1000

2100

70/239

£25.63

£32.04

3100

95/324

£30.08

£37.60

4100

125/427

£35.65

£44.56

1200

2120

83/282

£31.87

£39.84

3120

115/392

£40.10

£50.13

4120

147/502

£50.13

£62.66

1500

2150

104/355

£37.54

£46.93

3150

140/478

£49.02

£61.28

4150

180/614

£63.50

£79.38

1800

2180

124/423

£41.44

£51.80

3180

166/566

£56.82

£71.03

4180

213/727

£71.30

£89.13

2000

2200

138/471

£45.68

£57.10

3200

183/624

£64.62

£80.78

4200

234/798

£79.10

£98.88

RRP white (ex VAT)

RRP colour (ex VAT)

RRP white (ex VAT)

RRP colour (ex VAT)

Nominal Model Output 50∆T Height code Watts/BTU mm

Model Output 50∆T code Watts/BTU 6 column

Zehnder Charleston - 5 column 300

5030

52/177

£27.85

£34.81

6030

61/209

£34.64

£43.30

400

5040

68/232

£28.96

£36.20

6040

81/275

£36.32

£45.40

450

5045

76/259

£30.08

£37.60

6045

90/306

£37.21

£46.51

500

5050

84/285

£30.64

£38.30

6050

99/338

£38.11

£47.64

550

5055

91/310

£31.87

£39.84

6055

108/369

£39.22

£49.03

600

5060

99/336

£32.98

£41.23

6060

117/399

£40.33

£50.41

750

5075

120/409

£34.09

£42.61

6075

143/488

£42.00

£52.50

900

5090

141/481

£38.66

£48.33

6090

167/570

£48.91

£61.14

1000

5100

154/525

£44.34

£55.43

6100

183/624

£55.70

£69.63

1200

5120

179/611

£57.93

£72.41

6120

210/717

£72.75

£90.94

1500

5150

219/747

£77.31

£96.64

6150

256/873

£90.91

£113.64

Max. working pressure: 10 bar

All data and prices per 46mm section

Zehnder 2 5 10 Charleston DAY

3-5

DAY

2 WEEKS

3-5

DAY

5-7

5

14

10 DAY WEEKS

3-5 15

WEEKS

4-6

DAY

20

The traditional column radiator for central heating, available as made-to-measure in horizontal, vertical, angled or curved forms, with 50 colours from which to choose. A range of welded-on feet are available if required. DAY

3-5

DAY

5-7

DAY

14

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

Dimensions: Nominal overall radiator length = (No. of sections x 46mm) + 26mm (Manufacturing tolerance of +/- 1.5% in length, +/- 2mm in height, +/- 5mm in depth).

Selection example: Output required: approximately 1000 watts Dimensions required: approximately 600mm H x 900mm L Formula: (No. of sections x 46mm) + 26mm Calculation of sections: 900mm - 26mm divided by 46 = 19 sections 1000w divided by 19 section = approximately 52 watts/section required Radiator selection: 3050 = 52 watts/section 52w x 19 section = 988 watts (50∆t) Price calculation: 19 sections x £19.95 = £379.05 plus VAT

CHARLESTON CURVED

Foot support options (wall brackets included as standard) Model

No of Feet RRP white (ex VAT) RRP colour (ex VAT)

Welded-on fixed - 150mm (WF150) or adjustable fixed - 120-170mm (WF120) feet with cover plate Price per radiator 8 - 20 sections

2

£65.50

£81.88

21 - 40 sections

3

£98.25

£122.81

41 - 60 sections

4

£131.00

£163.75

Technoline 0325. For more information please see page 58.

Welded-on traditional - 100mm (WF100) or 150mm (WFTF150) feet Price per radiator 2 - 20 sections

2 pairs

£89.00

£111.25

21 - 40 sections

3 pairs

£133.50

£166.88

41 - 60 sections

4 pairs

£178.00

£222.50

976131 white

1

£32.00

976139 colour

1

Adjustable foot (100-150mm).

Price per foot £40.00

Must always be used with wall brackets Cast iron foot (100mm high) ZPGG-9016

Price per foot 1

£22.00

EasyFix brackets The amount of pieces required depends on the height and width of the radiator. SMB-2PC SMB-3PC SMB-4PC SMB-5PC

£33.00 £50.00 £67.00 £83.00

£41.00 £63.00 £84.00 £104.00

Standard CVD brackets supplied with Charleston radiators - colour to match the radiator Note: Optional longer brackets available to order, to achieve longer distance from back of the radiator to the wall. CVD0 (supplied with the radiator) 28mm CVD1 43mm CVD2 63mm

EasyFix bracket for radiators 300mm to 1000mm in height

BLACK-SILVER HAMMERED 0422

EasyFix bracket for radiators below 260mm and above 1100mm in height

Prices for Easyfix Brackets are given as a guide – please contact us to determine which brackets you require depending on the size of your radiator. Due to manufacturing tolerances in this product we recommend that you do not pre-pipe. Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The complete 26

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-2-CR. For more information see page 48.

TRAFFIC WHITE 9016

January 2019

27


KLEO

TUBULAR COLUMN RADIATOR

Central Heating Model STOCK listed in black

Height mm

Width mm

Number of tubes

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

2

RRP (ex VAT)

5

2 5 10 Zehnder Kleo DAY

DAY

3-5

Zehnder Kleo vertical KLV-180-030 KLV-180-040 KLV-180-050 KLV-180-060 KLVC-180-030 KLVC-180-040 KLVC-180-050 KLVC-180-060

1800 1800 1800 1800 1800 1800 1800 1800

299 398 497 596 299 398 497 596

9 12 15 18 9 12 15 18

white white white white chrome chrome chrome chrome

632/2156 842/2874 1053/3593 1260/4320 448/1529 597/2040 747/2549 896/3057

£217 £265 £313 £361 £404 £493 £583 £672

KLH-058-100 596 KLH-058-120 596 KLH-058-140 596 KLHD-058-100 596 KLHD-058-120 596 KLHD-058-140 596 Max. working pressure: 11.5 bar

1000 1200 1400 1000 1200 1400

18 18 18 18 18 18

white white white white white white

782/2668 938/3201 1094/3735 1211/4134 1453/4961 1695/5787

£273 £299 £324 £478 £523 £568

10

5-7

DAY

14

DAY WEEKS

17 3-5

2

DAY

3-5

5

DAY

5-7

10

WEEKS DAY

3-5 14

WEEKS

4-6

DAY

20

DAY WEEKS

17 3-5

A contemporary tubular column radiator in vertical and horizontal orientations, supplied from stock in a RAL 9016 white finish or stylish, modern chrome. Brackets and an air vent included. DAY WEEKS

3-5 3-5

DAY WEEKS

5-7 4-6

DAY DAY

1420

DAY WEEKS

17 3-5

Zehnder Kleo horizontal

WEEKS

3-5

WEEKS

4-6

DAY

20

Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The KLV can also be installed horizontally with TBSE connections on either side

KLH KLHD KLHC

KLH KLHD KLHC

*1/8” air vent Width excludes air vent F = flow R = return Tube: Horizontal \ 38mm Tube: Vertical \ 20mm All dimensions in mm Max. working pressure: 4 bar

KLH KLHC

KLH KLHD KLHC

KLH KLHC

KLH KLHC

KLH KLHC

KLHD

KLV KLVC

KLV KLVC

KLH KLHD KLHC

KLHD

KLH KLHC

KLH KLHD KLHC

KLH KLHC

KLVC-180-060 TRAFFIC WHITE 9016

KLHD

Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. The complete 28

compliant technical specifications can be found between pages 49 and 57. KLHD

KLHD

Zehnder recommends VAL-SET-2-CR. For more information see page 48. KLVC-180-040 CHROME 0008

January 2019

29


LYTA-S

HORIZONTAL ALUMINIUM

Central Heating Model STOCK listed in black

Height mm

Width mm

Number of sections

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

RRP (ex VAT)

546/1863 728/2484 910/3105 1092/3726 1274/4347 737/2516 983/3354 1229/4193 1475/5032 1721/5871 848/2895 1131/3860 1414/4824 1697/5789 1980/6754

£162 £216 £270 £324 £378 £168 £224 £280 £336 £392 £174 £232 £290 £348 £406

2 5 10 Zehnder Lyta-S

Zehnder Lyta-S LYSV-Z-040-048 LYSV-Z-040-064 LYSV-Z-040-080 LYSV-Z-040-096 LYSV-Z-040-112 LYSV-Z-055-048 LYSV-Z-055-064 LYSV-Z-055-080 LYSV-Z-055-096 LYSV-Z-055-112 LYSV-Z-065-048 LYSV-Z-065-064 LYSV-Z-065-080 LYSV-Z-065-096 LYSV-Z-065-112

395 395 395 395 395 545 545 545 545 545 645 645 645 645 645

480 640 800 960 1120 480 640 800 960 1120 480 640 800 960 1120

6 8 10 12 14 6 8 10 12 14 6 8 10 12 14

white white white white white white white white white white white white white white white

Max. working pressure: 16 bar When adding or removing sections; joining nipples, gaskets and an assembly tool should be additionally purchased as required for the installation. Please note, brackets for this order will be delivered in a separate box and will appear as a separate line listing on your delivery note.

Accessories RRP (ex VAT) £72 £51 £51 £51 £51 £2.60 £0.60 £1.30 £24 £23

Towel rail for 6 section Lyta-S. White RAL9010 (see below) Aluminium assembly tool 300 Aluminium assembly tool 600 Aluminium assembly tool 900 Aluminium assembly tool 1200 1 inch steel joining nipple -for use with Lyta-S Joining nipple gasket for joining the Lyta-S. White RAL 9010 Gasket for end plugs for Lyta-S - Green Installation bush and bracket pack for Lyta-S Service assembly kit for the Lyta-S radiator

Height-77

Model A36/6 905110 905120 905130 905140 A2/1 A10/1 A11/1 A81 A80

2

5

10

DAY

3-5

DAY

5-7

DAY

14

DAY WEEKS

17 3-5 DAY

3-5

A high output, low water content, die-cast aluminium radiator, giving a fast response, comfortable heat with high thermal energy efficiency. Easy to handle, the Lyta-S is resistant to corrosion with the ability to add or remove sections according to requirements. Brackets (separate box), plugs, bushes and air vent are included. DAY

5-7

DAY

14

WEEKS

3-5

WEEKS

4-6

DAY

20

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

By

*1/2” air vent Width excludes air vent F = flow R = return H = height W = width All dimensions in mm

Width+24

The complete 30

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-2-CR. For more information see page 48. LYSV-Z-065-064 PURE WHITE 9010

January 2019

31


LYTA-T

VERTICAL ALUMINIUM

Central Heating Model STOCK listed in black

Height mm

Width mm

Number of sections

Finish

Output ∆T=50K Watts/Btu All outputs certified to EN 442

RRP (ex VAT)

728/2484 1092/3726 1000/3412 1500/5118 900/3071 1200/4094 1500/5118 1800/6142

£232 £348 £328 £492 £291 £388 £485 £582

2 5 10 Zehnder Lyta-T

Zehnder Lyta-T LYTV-Z-097-032 LYTV-Z-097-048 LYTV-Z-147-032 LYTV-Z-147-048 LYTV-Z-187-024 LYTV-Z-187-032 LYTV-Z-187-040 LYTV-Z-187-048

966 966 1466 1466 1866 1866 1866 1866

320 480 320 480 240 320 400 480

4 6 4 6 3 4 5 6

white white white white white white white white

Max. working pressure: 16 bar When adding or removing sections; joining nipples, gaskets and an assembly tool should be additionally purchased as required for the installation. Please note, brackets for this order will be delivered in a separate box and will appear as a separate line listing on your delivery note.

Accessories Model 905110 905120 905130 905140 A32/1 A33/1 A82 A36/4 A36/5 A36/6

Aluminium assembly tool 300 Aluminium assembly tool 600 Aluminium assembly tool 900 Aluminium assembly tool 1200 Gasket for nipples, plugs and adaptors for Lyta-T - Black 1 inch steel joining nipple for Lyta-T Installation bush and bracket pack for Lyta-T Towel rail for 4 section Lyta-T. White (RAL9010) Towel rail for 5 section Lyta-T. White (RAL9010) Towel rail for 6 section Lyta-S and Lyta-T. White (RAL9010)

RRP (ex VAT) £51 £51 £51 £51 £1.30 £2.80 £24 £57 £66 £72

2

5

10

DAY

3-5

DAY

5-7

DAY

14

DAY WEEKS

17 3-5 DAY

3-5

The Lyta is a high output, low water content, extruded aluminium radiator. Resistant to corrosion, sections can be added or removed to suit installation requirements. The Lyta-T has the practical option of a towel bar. Brackets (separate box), plugs, bushes and air vent are included. DAY

5-7

DAY

14

WEEKS

3-5

WEEKS

4-6

DAY

20

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

By

*1/2” air vent Width excludes air vent F = flow R = return H = height W = width All dimensions in mm

The complete 32

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-2-CR. For more information see page 48.

LYTV-Z-187-040 PURE WHITE 9010

January 2019

33


RODA NEW

FLAT PANEL RADIATOR

Central Heating Model STOCK listed in black

Height mm

Width mm

Overall projection

Finish

Number of tubes

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Weight kg

RRP (ex VAT)

70 70 70 70 70 70

white white white white white white

4 5 6 7 8 9

568/1940 710/2425 852/2910 994/3395 1136/3880 1278/4365

12.0 15.0 18.0 21.0 24.0 27.0

£207 £242 £277 £312 £347 £382

93 93 93 93 93 93

white white white white white white

4 5 6 7 8 9

824/2812 1030/3515 1236/4218 1442/4921 1648/5624 1854/6327

22.4 28.0 33.6 39.2 44.8 50.4

£333 £396 £459 £522 £585 £648

Zehnder Roda Vertical Single panel ROV-180-029 ROV-180-037 ROV-180-044 ROV-180-051 ROV-180-059 ROV-180-066

1800 1800 1800 1800 1800 1800

296 370 444 518 592 666

Zehnder Roda Vertical Double panel ROVD-180-029 ROVD-180-037 ROVD-180-044 ROVD-180-051 ROVD-180-059 ROVD-180-066

1800 1800 1800 1800 1800 1800

Central Heating Model STOCK listed in black

Height mm

74

3-5

Width mm

Overall projection

Finish

Number of tubes

Output ∆T=50K Watts/Btu All outputs certified to EN 442

Weight kg

RRP (ex VAT)

70 70 ?? 70 70 70

white white white white white white

7 7 8 8 8 8

586/1999 703/2399 532/1815 150 665/2269 798/2723 931/3177

13.4 16.1 4.48 14.1 18.1 19.7

£208 £229 £211 £235 £259 £283

18 21.59 13.2 17.6 22.0 26.4 30.72 35.1

£315 £353 £259 £301 £344 £387 £429 £472

74

10

5 5 DAY

5-7

2

5

DAY

DAY

3-5

WEEKS

ROV & ROVD can be installed horizontally with TBSE connections either side.

ne vertical

DAY

3-5

296 370 444 518 592 666

Fassane horizontal Fassane horizontal

ertical

Zehnder 2 Roda 2

5-7

WEEKS

4-6

10 DAY

14

10 DAY DAY WEEKS

1714 3-5

DAY DAY

WEEKS 203-5 17

A perfect example of a simple & classic radiator, the Zehdner Roda is efficient enough for all living areas and adds a touch of style to any space. WEEKS DAY

3-5 3-5

WEEKS DAY

4-6 5-7

DAY DAY

20 14

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

7 7 8 8 8 8 8 8

100

F/R ROVD R/F

H

42

42

927/3163 1112/3794 W 636/2170 848/2894 1060/3617 1272/4340 1504/5132 34 1718/5862

W-68 ROH ROH W-68 34 ROHD ROH R ROHL F ROHD flow & return can be manufactured reversed on request ROHL R F white 8 636/2170 flow & return can be manufactured reversed on request

Fassane horizontal ertical Fassane horizontal vertical ertical ROV

Zehnder RodaROV Horizontal Double panel

ROH W

110

white white white white white white white 34 white H

200

70 70 92 92 92 92 70 70

34

ROH

34

H

W-49

1000 1200 600 800 1000 1200 1400 1600

100

518 518 592 592 592 592 592 24.5 592

H

ROHL-052-100 ROHL-052-120 ROHL-059-060 ROHL-059-080 ROHL-059-100 ROHL-059-120 ROHL-059-140 24.5 ROHL-059-160

150

ROH

Zehnder Roda Horizontal Single panel with single convector fin w

150

110

ROV

150

34

70

74

70

w

1000 1200 800 741000 1200 1400

70

ROV

42

518 518 592 592 592 592

42

70

ROH-052-100 ROH-052-120 ROH-059-080 ROH-059-100 ROH-059-120 ROH-059-140

200

Zehnder Roda Horizontal Single panel

ROHL-059-060

592

600

92

13.2

£307

ROHL-059-080

592

800

92

white

8

848/2894

17.6

£348

92 92

white white

8 8

1060/3617 1272/4340

22.0 26.4

£389 £430

ROHL-059-100 ROHL-059-120

24.5

W-49 592 ROV 592

F/R ROVD R/F

24.5

1000 1200

ROV

ROVD-180-029-TRAFFIC WHITE 9016

Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks.

ROH W

W

ROHL ROHL

F/R R/F flow & return be reversed W-49 24.5 24.5 24.524.5 can W-49 24.524.5 W-49 24.5 W-49 24.5 ROV ROV ROVD ROV ROV ROV ROVD ROVD R/F ROVR/FF/R F/RF/R R/F flow & return F/R ROVD R/F can be reversed

The complete 34

ROVD

34

ROHD

34

compliant technical specifications can be found between pages 49 and 57.

ROH ROHL

ROHD

34

W-68

ROHD 34 W-68 34 W-68 34 R F ROH ROHD ROHD FROHL R F W-68 34 flow34& return can be manufactured reversed on request ROH ROHD ROHL F R flow & return can be manufactured reversed on request

H

ROVD

100

ROVD

24.5 100 100 100

W-49

34 110

34

24.5

34

H

H

W

ROHL

R ROH

34

100

H

H HH

H

W ROHL ROH

150 ROHD

110

150

110

70

200

200 200 200

H

150

150

ROHD

w

w w w

150

*1/8” air vent Width excludes air vent F = flow R = return H = height W = width Tube dimensions 70mm x 11mm Vertical tubes: \ 38mm All dimensions in mm

110

150

70

150

66

200 ROVD

66

42 42 42

93

70 70 70

ROV ROV ROV

150

66

74

42

74 74 74

ROHL

42

w74

93

ROVD

93

74 74 74

74

66

93

74

X = Variation in radiator height. 2 - 4 tubes tall = 35mm 5 tubes tall = 109mm 6 tubes tall = 55mm 7 tubes tall = 129mm 8 tubes tall = 63mm

Zehnder recommends VAL-SET-2-CR. For more information see page 48.

ROH-059-080 TRAFFIC WHITE 9016

January 2019

35


RODA MADE TO MEASURE NEW

M2M FLAT PANEL

Zehnder Roda (ROV) vertical, single panel white Width

Height (mm)

(mm)

No of tubes

ROV-060 600

ROV-080 800

ROV-100 1000

ROV-120 1200

ROV-140 1400

ROV-160 1600

ROV-180 1800

ROV-200 2000

ROV-220 2200

296

4

£134

£144

£159

£169

£183

£197

£207

£221

£232

370

5

£154

£166

£184

£196

£213

£230

£242

£259

£272

444

6

£174

£188

£209

£223

£243

£263

£277

£297

£312

518

7

£194

£210

£234

£250

£273

£296

£312

£335

£352

592

8

£214

£232

£259

£277

£303

£329

£347

£373

£392

666

9

£234

£254

£284

£304

£333

£362

£382

£411

£432

740

10

£254

£276

£309

£331

£363

£395

£417

£449

£472

52/177

68/232

83/283

98/334

113/386

127/433

142/485

155/529

169/577

Technical data per tube

Zehnder 2 5 Roda DAY

3-5

2 WEEKS

3-5

Watts/BTU

Output calculation example 50∆t (watts):

3-5

Zehnder Roda (ROVD) vertical, double panel white Width

Height (mm) ROVD-060 ROVD-080 ROVD-100 ROVD-120 ROVD-140 ROVD-160 ROVD-180 ROVD-200 ROVD-220 600 800 1000 1200 1400 1600 1800 2000 2200

296

4

£200

£224

£246

£264

£287

£309

£333

£355

£377

370

5

£234

£263

£290

£312

£340

£367

£396

£423

£450

444

6

£268

£302

£334

£360

£393

£425

£459

£491

£523

518

7

£302

£341

£378

£408

£446

£483

£522

£559

£596

592

8

£336

£380

£422

£456

£499

£541

£585

£627

£669

666

9

£370

£419

£466

£504

£552

£599

£648

£695

£742

740

10

£404

£458

£510

£552

£605

£657

£711

£763

£815

77/263

100/341

122/416

144/491

165/563

186/635

206/703

225/768

244/833

Technical data per tube

Output 50∆T

(Watts/BTU)

Output calculation example 50∆t (watts):

5

10 DAY WEEKS

17 3-5

WEEKS

4-6

DAY

20

DAY

5-7

DAY

14

17 3-5

WEEKS

No of tubes

DAY

14

DAY WEEKS

1800H x 592W: 142 x 8 = 1136w

3-5

(mm)

DAY

5-7

Made-to-measure Zehnder Roda radiators are easy and quick to order. They are simple, effective and efficient decorative radiators, available as horizontal or vertical and are perfect for all living areas. DAY

Output 50∆T

10

WEEKS

4-6

DAY

20

1800H x 592W: 206 x 8 = 1648w

Zehnder Roda (ROH) horizontal, single panel white Height

Technical data per metre

Width (mm)

Model Code

(mm)

No of tubes

Output 50∆T Watts/BTU

600

800

1000

1200

1400

1600

1800

2000

2200

ROH-030

296

4

344/1174

£106

£118

£130

£142

£154

£167

£179

£191

£203

ROH-037

370

5

425/1450

£125

£140

£155

£170

£185

£200

£215

£230

£245

ROH-044

444

6

506/1726

£147

£165

£183

£201

£219

£238

£256

£274

£292

ROH-052

518

7

586/1999

£166

£187

£208

£229

£250

£271

£292

£313

£334

ROH-060

592

8

665/2269

£187

£211

£235

£259

£283

£307

£331

£355

£379

ROH-067

666

9

744/2537

£207

£234

£261

£288

£315

£342

£369

£396

£423

ROH-074

740

10

823/2806

£227

£257

£287

£317

£347

£377

£407

£437

£467

Output calculation example 50∆t (watts):

518H x 1200L: 586 x 1.2 = 667w

Zehnder Roda (ROHL) horizontal, single panel, single fin white Height

Technical data per metre

Width (mm)

Model Code

(mm)

No of tubes

Output 50∆T Watts/BTU

600

800

1000

1200

1400

1600

1800

2000

2200

ROHL-014

148

2

350/1194

£152

£171

£190

£209

£228

£246

£265

£284

£303

ROHL-022

222

3

511/1744

£157

£178

£198

£218

£239

£259

£280

£300

£320

ROHL-030

296

4

637/2173

£177

£202

£227

£252

£277

£301

£326

£351

£376

ROHL-037

370

5

719/2453

£198

£227

£256

£285

£314

£344

£373

£402

£431

ROHL-044

444

6

845/2883

£218

£251

£285

£319

£352

£386

£419

£453

£487

ROHL-052

518

7

927/3163

£239

£277

£315

£353

£391

£430

£468

£506

£544

ROHL-060

592

8

1060/3617

£259

£301

£344

£387

£429

£472

£514

£557

£600

ROHL-067

666

9

1157/3945

£279

£326

£373

£420

£467

£514

£561

£608

£655

ROHL-074

740

10

1237/4218

£300

£351

£403

£455

£506

£558

£609

£661

£713

Output calculation example 50∆t (watts):

Made-to-measure

518H x 1200L: 927 x 1.2 =1112w

Details on intermediate sizes are available on request (1-20 tubes) Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. All prices exclude VAT The complete 36

compliant technical specifications can be found between pages 49 and 57.

Zehnder recommends VAL-SET-2-CR. For more information see page 48.

ROV-160-5 PERGAMON 0081

January 2019

37


STANA

LOW LOVEL CONVECTOR

Central Heating

Height mm

Width mm

Depth mm

Finish

Output ∆T=50 Watts/btu All outputs certified to EN 442

RRP (ex VAT)

STN-015-014-100

250

1000

140

white

625/2133

£308

STN-015-014-120

250

1200

140

white

750/2559

£345

STN-015-014-140

250

1400

140

white

875/2986

£383

STN-015-014-150

250

1500

140

white

875/3199

£402

STN-015-014-160

250

1600

140

white

1000/3412

£420

STN-015-014-200

250

2000

140

white

1250/4265

£495

STN-015-020-100

250

1000

200

white

993/3388

£441

STN-015-020-120

250

1200

200

white

1192/4066

£493

STN-015-020-140

250

1400

200

white

1390/4743

£545

STN-015-020-150

250

1500

200

white

1490/5082

£571

STN-015-020-160

250

1600

200

white

1589/5421

£597

STN-015-020-200

250

2000

200

white

1986/6776

£701

Model STOCK listed in black

Zehnder Stana

Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 4-6 weeks.. Accessories

Finish

RRP (ex VAT)

White

£21

Chrome

£23

Model 819080

Zehnder white TRV head (M30 x 1.5)

819088

Zehnder chrome TRV head (M30 x 1.5)

2 5 Zehnder Stana DAY

3-5

DAY

10 31

2

5

WEEKS

3-5

DAY

5-7

DAY

31

10 WEEKS

4-6

10 2

DAY

14

5

10

DAY

30

DAY DAY

20 3-5

DAY

10 31

DAY

5-7

DAY

31

DAY

14

DAY

30

On the floor in front of a window or in an alcove. Zehnder Stana enables ideal distribution of heated air throughout the room. Understated design and a variety of models ensure that Zehnder Stana fits perfectly into any setting. DAY

3-5

DAY

5-7

DAY

14

WEEKS

3-5

WEEKS

4-6

DAY

20

DAY WEEKS

17 3-5

WEEKS

3-5

WEEKS

4-6

DAY

20

Note: TRV Headnot supplied with radiator Refer to website for Stana colour chart

W

100

H

F = flow R = return H = height T = depth W = width L = Length Dimensions in mm 150 50 25 R

F

T

W

70

STN-015-014 STN-015-014

260

175

200

175

175

140

100

Scan the QR code for the Zehnder Stana colour chart. 130

STN-015-020 STN-015-020

Note: comes with integral valve The complete 38

compliant technical specifications can be found between pages 49 and 57.

STN-015-014-140 ANTHRACITE 0346 STN-015-014-160 WHITE 9016

January 2019

39


ELECTRIC RADIATORS

ALURA Electric Heating Model STOCK listed in bold

Height mm

Width mm

Finish

No. of sections

With factory fitted controls, Class ll IPX4 Electric Rating (Watts)

Weight kg

RRP (ex VAT)

372 472 572 772 872 1172

white* white* white* white* white* white*

3 4 5 7 8 11

500 750 1000 1250 1500 2000

7 9 11 15 17 23

£282 £308 £347 £407 £451 £553

2 5 10 Alura Zehnder

Zehnder Alura Electric ALE-050-036/F ALE-075-046/F ALE-100-056/F ALE-125-076/F ALE-150-086/F ALE-200-116/F *white (RAL 9010)

575 575 575 575 575 575

DAY

3-5

2

DAY

5-7

5

DAY

14

10

DAY WEEKS

17 3-5

This fast response electric aluminium radiator has a high output in relation to its size. Its weight and size makes this radiator easy to install, and the straightforward digital controls make it easy and economical to use. H shaped mounting bracket with removable spirit level and locking system included. WEEKS

3-5

DAY WEEKS

3-5 4-6

DAY DAY

5-7 20

DAY

14

DAY WEEKS

17 3-5

Temperature controller: Backlit LCD digital display screen gives complete control. Temperature can be adjusted in 0.5°C increments. 3 pre-set programmes and 5 mode settings. Open window detection system and parental lock.

WEEKS

3-5

H = height W = width All dimensions in mm

W

H

Open Window detection The Integral control unit recognises if a window has been opened for an extended period and switches the radiator off. Once the window is closed, the radiator returns to normal operation. External temperature sensor recognises temperature changes. Integral thermostat reacts to sensor information Radiator automatically switches off if a window is open for an extended period. Intelligent heating that saves energy and costs.

WEEKS

4-6

DAY

20

Alura

ALE-100-056/F PURE WHITE 9010 CHARLESTON & CHARLESTON PLINTH Watts Electric Heating number Radio frequency remote programmer IPX4 Weight RRP Height Width Model STOCK of Finish mm mm Zone 1 Bath, Zone 2 Shower, Class II kg (ex VAT) listed in black sections

Zehnder Charleston & 2 5 10 Charleston Plinth

Zehnder Charleston Electric NZ-060-053/GF NZ-060-062/GF NZ-060-076/GF NZ-060-089/GF NZ-060-103/GF NZ-060-131/GF 576

600 530 600 622 600 760 600 898 600 1036 600 1312 714

10 white 12 white 15 white 18 white 21 white 27 white

500 750 1000 1250 1500 2000

£482 27.0 £562 30.0 41.0 £608 47.0 £710 58.0 £765 £921 70.0

20

1000

42.4

Zehnder Charleston Plinth Electric

NZ-030-100/GF

300

995

white

£800

DAY

Colour finish: Standard colours from the Zehnder colour chart including matt white finish: white RAL 9016 + 25%. Colour finish and non-stock products delivery: 3-5 weeks. 600

600

3-5

DAY

WEEKS

3-5

RRP (ex VAT)

601020594 966018 NZ-060-062/GF 966028

H = height W = width Width includes controller All dimensions in mm

£56.00 £138.00 £154.00

Lambswool732 cleaning brush Charleston towel bar 368mm NZ-060-076/GF Charleston towel bar 918mm

2

WEEKS

4-6

DAY

3-5

DAY

10

DAY

5-7

DAY

14

DAY WEEKS

17 3-5

WEEKS

H

H

600

576

600

600

484

40

5

20

The Zehnder Charleston is an electric, oil-filled multi-column radiator available in 6 sizes ideal for 714 installation in loft conversions. The complementary Zehnder Charleston Plinth low level model is perfectly suited to conservatories and in front of low-level windows. 3-5

F

DAY

14

16

Accessories Model

DAY

5-7

W

W

Charleston Electric

Charleston Plinth NZ-030-100/GF

502 NZ-060-053/GF

594 NZ-060-062/GF

WEEKS

4-6

DAY

20

732

NZ-060-076/GF

NZ-060-089/GF TRAFFIC WHITE 9016 852

990

January 2019

41


EXTRACTOR FANS

Zehnder Low Energy Continuous Fan Ø100mm

100% adjustable speed

er ™ TimART SM

er ™ TimART SM

i midT™ Hu AR SM

Continuous ventilation ensures a continually fresh environment with a constant low level trickle and then boost linked to room usage and often high moisture levels! i midT™ Hu AR SM

This low energy design costs as little as £1.50 to run for the entire year and is quiet running so operates in the background discretely ensuring issues such as mould and condensation are kept at bay. With SMART humidity and timer controls, nuisance noise and running are completely eliminated leaving you to relax in the surroundings of your bathroom. Model STOCK listed in black

Did you know that a shower can create up to 2 pints of moisture? Add this to boiling the kettle, cooking, drying clothes and breathing and there is a lot of moisture in your home, not to mention other airborne particles such as dust and VOC’s!

42

D IP (Spigot) Rating

IPX4 Ceiling 68 IPX5 Wall

Airflow l/s in FREE AIR (BS848 Pt 1)

Speed

Trickle

5

8

Boost

8

13

Maximum

23

23

RRP (ex VAT)

Accessories Wall fan accessories mm

375

ZED1A ZEG1WA

ZFF100W ZFF100B

Plastic wall inner with integral screw-fixing channels Fixed blade louvered external wall vent in white Fixed blade louvered external wall vent in brown Fast fix wall duct system with external grill available in white (W) or brown (B)

£7 £4 £4 £15

Ceiling fan accessories ZGFP4.3A

This range of fans offer high performance extraction, decorative or discreet style and low noise options - all that you need from your bathroom fan.

H

Sound Energy pressure level Consumption (W) Min Max dB(A)

10.1-23.5

1.1

5.4

RRP (ex VAT)

£104

Accessories for all bathroom fans

ZEG1BA

Ventilation is crucial to every home, and especially in bathrooms and kitchens.

W

Continuous trickle speed with boost activated by lightswitch or smart humidity sensing. Optional SMART overrun 199 129.5 timer. Easy set on touch pad located on the fan fascia. Quiet running, low energy design

ZCV2

Ventilation - extractor fans.

Control Operation

Ceiling Application (unit can be wall or ceiling mounted)

ZGG42WA ZGG42BA

Flexiduct 3m x Ø100mm (required for ceiling fitting) 100mm External grille with spigot in white 100mm External grille with spigot in brown

£10 £4 £4

Zehnder Adaptive fan with “smart” timer technology and pull cord option. The length of time of the fan over-run is r based on occupancy duration, up to a me Ti ART SM maximum run-time of 15 minutes, reducing heat idi loss and energy usage. um T r me ™ Ti ART M S

H AR SM

Zehnder Adaptive fan with “smart” humidistat and timer technology and pull cord option. The fan knows the normal humidity level and only activates when spikes occur, providing the right amount of ventilation when required, unlike fans with a generic point that respond to high ambient humidity on a summer’s day and particularly in the middle of the night. di mi T™ Hu AR SM

All fans suitable for wall or ceiling mounting with discharge through an external wall or soffit, but not the roof. Please see pages 44 and 46 for diagrams. Not for use with more than 3m of ducting.

January 2019

43


EXTRACTOR FANS

SILENT WALL & CEILING FANS Model STOCK listed in black

Description

ZSR100B10A

Silent fan Basic

ZSR100TR11A

Silent fan Timer

ZSR100HTR12A

Silent fan Humidistat

Controls

Airflow l/s in FREE AIR (BS848 Pt 1)

Sound pressure level @ 3m dB(A)

Energy Consumption (W)

IP Rating

RRP (ex VAT)

Single speed. Operation by light/ remote switch

26

26.7

13

IPX4 Zones 1&2

£63

26

26.7

16

IPX4 Zones 1&2

£75

26

26.7

16

IPX4 Zones 1&2

£99

Single speed. Operation by light/ remote switch. Adjustable overrun timer (2-30 mins & preset at 15 mins) Single speed. Automatic operation by humidity control with option for manual override switch. Adjustable humidity (70-90% & set at 70%). Adjustable overrun timer to prevent hunting

Zehnder Silent Wall & Ceiling Fans Ø100mm 3

180mm

33

The range of Zehnder Silent fans offer “whisper-quiet” operation – typically a minimum of 70% less noise than standard fans. This range has been developed in response to customers who want high performance ventilation without nuisance noise. 3 year warranty.

160mm

180mm

Ø 97mm

All fans suitable for wall or ceiling mounting with discharge through an external wall or soffit, but not the roof. Not for use with more than 3m of ducting.

142mm

Standard ceiling installation

ZSR100 wall fans Zehnder Silent Fan - Front Fascia Options

Option 1

Option 2

Option 3

ADAPTIVE WALL & CEILING FANS Airflow l/s in FREE AIR (BS848 Pt 1)

Sound pressure level @ 3m dB(A)

Energy Consumption (W)

Model STOCK listed in black

Description

ZLE100TA

Single speed operation by light/ remote switch or via integral pull cord. Low Energy Adaptive Fan with Adaptable speeds (1-6) to ensure SMART Timer installed performance between 1-6. SMART overrun timer

13.6

31

25

45

1.6

ZLE100HTA

Single speed operation via light/ Low Energy remote switch or via integral pull Adaptive Fan with cord. Adaptable speeds (1-6) to SMART humdistat ensure installed performance. SMART and timer humidity and overrun timer

13.6

31

25

45

1.6

Controls

IP Rating

RRP (ex VAT)

8.9

IPX4 Zones 1&2

£94

8.9

IPX4 Zones 1&2

£140

All fans suitable for wall or ceiling mounting with discharge through an external wall or soffit, but not the roof. Refer to speeds for maximum ducting lengths

100mm fan suitable for through wall and ducted ceiling/wall installation. Installation Through Wall + <3m Ducting <1.5m Ducting Window Kit Through Wall Window Kit <3m Ducting

160

39.8

115 103.5

160

Room WC Bathroom WC Bathroom Bathroom Bathroom

Ø99

Speed 1 2 3 4 5 6

The speed of the fan is set by the installer according to the size and use of the room, thus avoiding over or under ventilation. See standard ceiling installation diagram above.

ZLE100 wall fans

44

Zehnder Adaptive Wall & Ceiling Fans Ø100mm 3

The economical low-energy, quiet Zehnder Adaptive fan offers the latest in extractor fan technology - adaptive extraction - offering 6 pre-set speeds for different installation applications to ensure the fan is doing the job it’s supposed to and eliminating issues with mould and condensation 3 year warranty. January 2019

45


EXTRACTOR FANS

SILENT SHOWER FAN KIT Description

Controls

Airflow l/s in FREE AIR (BS848 Pt 1)

Sound pressure level @ 3m dB(A)

Energy Consumption (W)

IP Rating

RRP (ex VAT)

ZSR100TSKA

Silent Timer Shower Kit

Single speed, 230V. Operation by light/remote switch Adjustable timer. Kit includes induct fan, 90° end,3 metres of Flexiduct, 4 fixing clips, ceiling grills and fixing screws

31

20

16

IPX4 Zones 1&2

£96

ZSR100ETSKA

Single speed, 230V. Operation by light/remote switch. Adjustable timer. Kit includes induct fan, 12V light unit, Silent Timer light transformer, 90° bend, 3 metres Shower Kit & Light of flexiduct, 4 fixing clips, ceiling grille and fixing screws. Provided with white & chrome bezels.

31

20

Fan 16W,12V lamp IPX4 Zones rated at 6W 1&2

£143

Model STOCK listed in black

Length of ductwork should not exceed the length of the ducting supplied Recommended for discharge through an external wall or soffit, but not the roof.

Ø 145mm

Ø 138mm

11.50mm

Ø 99mm

65mm

40mm

Ø 100mm

Zehnder Silent Shower Fan Kit 3

Silent fans are 70% quieter than standard axial fans when operating. Supplied as shower kits with or without a LED light in “warm white” (2700K) and with a 3 year warranty.

11mm

ZSR100TSKA

ZSR100ETSKA Zehnder Silent ø100mm Induct Fans

Soffit installation

HALO DESIGNER SHOWER FAN & LED LIGHT KIT Sound pressure level @ 3m dB(A)

Single speed, 230V. Operation by light/remote switch Adjustable timer (2-30mins and factory set at 15 mins). Kit includes ø125mm induct fan, internal rgrille with low voltage 12V light and transformer, 90° bend, 3 metres of flexiduct, 4 fixing Shower Fan clips, 110 ceiling grill and fixing screws. White & Chrome bezels provided

56

31

£117

71

71 122

Surface cable entry

122

Surface cable entry

162

3

59

Ø119

71

Ø115

115 55.5

Surface cable entry

122 Ø118

162

59

87

Ø119

41.5

87

Ø118

175

41.5

115 55.5

Soffit installation

Zehnder Halo Designer Shower Fan & LED Light Kit Ø125mm

Foot

162

90˚Bend

RRP (ex VAT)

Fan 20W, 12V lamp IPX4 Zones rated at 6W 1&2

90˚Bend

59

IP Rating

Shower Fan 110

Foot

Shower Fan 110 90˚Bend

Energy Consumption (W)

Foot

Ø115

timer ceiling fan shower kit and LED light

Airflow l/s in FREE AIR (BS848 Pt 1)

Ø119

ø125mm Halo ZHC115ETSKA

Controls

Ø115

Description

115 55.5

Model STOCK listed in black

Ø180

175 Ø118

41.5

87

Ø180

Today’s luxurious showers and bathrooms call for high performance and high design. The Zehnder Halo is a ceiling extractor fan supplied as a kit with an integrated LED light in “warm white” (2700K). 3 year warranty.

175

46

Ø180

January 2019

47


ACCESSORIES

TECHNICAL SPECIFICATIONS Valves

Valves, dual energy and electric products

VAL-SET-1-CR Modern angled radiator valve set chrome plated. RRP (ex VAT) £44

VAL-SET-2-CR Contemporary double angled radiator valve set chrome plated. RRP (ex VAT) £61

Zehnder offers you a whole range of well matched valves and accessories to enhance aesthetics of your radiators and towels rails. The option of dual energy installation in the bathroom also guarantees luxury and comfort throughout the year. Electrical elements for Dual Energy installations

DE Pack 100 DE Pack 150 DE Pack 200 DE Pack 300 DE Pack 400 DE Pack 500 DE Pack 600 DE Pack 700 DE Pack 900

Watts

RRP (ex VAT)

100 150 200 300 400 500 600 700 900

VAL-SET-4-CR Mixed dual energy radiator valve set chrome plated. RRP (ex VAT) £44

RRP (ex VAT) £111

VAL-SET-18-CR Dual fuel right hand flow valve set chrome plated.

£139

RRP (ex VAT) £134

VAL-SET-19-CR Dual fuel left hand flow valve set chrome plated.

SHECZ-CR Simple immersion cable cover - chrome finish. RRP (ex VAT) £51

CTEW

RRP (ex VAT) £44

VAL-SET-8-CR Traditional valve set chrome plated.

Simple immersion - no controls IPX5 Model

VAL-SET-3-CR Stylish straight radiator valve set chrome plated.

RRP (ex VAT) £134

VAL-SET-20-CR Thermostatic dual fuel right hand flow valve set chrome plated.

CTEC

RRP (ex VAT) £185

Heat-adjustable, fuel saving electric element with 5 water-temperature settings between 30°C and 60°C: IPX4 Model

Finish

CTEW-120-DF white CTEW-200-DF white CTEW-300-DF white CTEW-400-DF white CTEW-600-DF white White T-piece included CTEC-120-DF chrome CTEC-200-DF chrome CTEC-300-DF chrome CTEC-400-DF chrome CTEC-600-DF chrome Chrome T-piece included 48

Watts 120 200 300 400 600 120 200 300 400 600

RRP (ex VAT)

£159

VAL-SET-21-CR Thermostatic dual fuel left hand flow valve set chrome plated. RRP (ex VAT) £185

Zehnder Aura (page 6) Stock Models Model code

Height mm

Width mm

PBZ-080-040 775 400 PBZ-080-050 775 500 PBZ-080-060 775 600 PBZ-120-050 1217 500 PBZ-120-060 1217 600 PBZ-150-050 1469 500 PBZ-150-060 1469 600 PBZ-180-050 1856 500 PBZ-180-060 1856 600 PBCZ-060-040 607 400 PBCZ-080-040 775 400 PBCZ-080-050 775 500 PBCZ-080-060 775 600 PBCZ-100-050 1027 500 PBCZ-120-040 1217 400 PBCZ-120-050 1217 500 PBCZ-120-060 1217 600 PBCZ-150-040 1469 400 PBCZ-150-050 1469 500 PBCZ-150-060 1469 600 PBCZ-180-040 1856 400 PBCZ-180-050 1856 500 PBCZ-180-060 1856 600 PBCZ-180-075 1856 750 PBZ-080-040-0346 775 400 PBZ-080-050-0346 775 500 PBZ-080-060-0346 775 600 PBZ-120-040-0346 1217 400 PBZ-120-050-0346 1217 500 PBZ-120-060-0346 1217 500 PBZ-180-050-0346 1856 500 PBZ-180-060-0346 1856 500 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C

Finish

Overall Projection mm

white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 white 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 chrome 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 anthracite 95 to 105 Test House: WSP LAB Test House No: 1428

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 356 456 556 456 556 456 556 456 556 356 356 456 556 456 356 456 556 356 456 556 356 456 556 706 356 456 556 356 456 556 456 556

65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75 65 to 75

287 358 418 512 598 631 740 788 925 151 186 230 271 287 278 330 390 346 407 481 432 513 607 741 287 358 418 427 512 598 788 925

979 1221 1426 1747 2040 2153 2525 2689 3156 515 635 785 925 979 949 1126 1331 1181 1389 1641 1473 1750 2071 2527 979 1221 1426 1457 1747 2040 2689 3156

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 152 194 228 273 319 335 395 418 491 79 96 120 143 149 142 171 203 177 211 250 221 264 316 387 152 194 228 227 273 319 418 491

519 662 777 932 1089 1143 1347 1427 1675 269 328 408 488 508 485 583 692 604 718 853 754 901 1077 1321 519 662 778 775 931 1088 1426 1675

1.23 1.20 1.19 1.23 1.23 1.24 1.23 1.24 1.24 1.27 1.27 1.28 1.25 1.28 1.28 1.29 1.28 1.29 1.29 1.28 1.30 1.30 1.28 1.27 1.23 1.2 1.19 1.23 1.23 1.23 1.24 1.24

5.58 5.74 6.2 7.89 8.92 9.79 11.1 12.07 13.67 3.60 5.6 5.76 6.23 6.7 8.0 7.92 8.96 9.8 9.83 11.15 10.45 12.12 13.72 17.20 5.58 5.74 6.2 7 7.89 8.92 12 13.67

3.1 3.6 4.1 5.2 5.9 6.5 7.4 8.0 9.1 2.6 3.1 3.6 4.1 4.5 4.5 5.2 5.9 5.6 6.5 7.4 7.1 8.0 9.1 10.7 3.1 3.6 4.1 4.7 5.2 5.9 8 9.1

200 200 300 300 400 400 500/400 500/400 600 100/n/a 100/n/a 150/120 150/120 200 200 200 300 300 300 300 300 300 400 500 200 200 300 300 300 400 500/400 600

Zehnder Aura Bow (page 10) Stock Models Model code

Height mm

Width mm

PBTZ-080-050 775 494 PBTZ-080-060 775 595 PBTZ-120-050 1217 494 PBTZ-120-060 1217 595 PBTZ-180-050 1856 494 PBTZ-180-060 1856 595 PBTCZ-080-050 775 494 PBTCZ-080-060 775 595 PBTCZ-120-050 1217 494 PBTCZ-120-060 1217 595 PBTCZ-180-050 1856 494 PBTCZ-180-060 1856 595 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C

Finish

Overall Projection mm

white 115 to 125 white 115 to 125 white 115 to 125 white 115 to 125 white 115 to 125 white 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 chrome 115 to 125 Test House: WSP LAB Test House No: 1428

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 450 551 450 551 450 551 450 551 450 551 450 551

55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65 55 to 65

358 418 512 598 788 925 230 271 330 390 513 607

1221 1426 1747 2040 2689 3156 785 925 1126 1331 1750 2071

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 194 228 273 319 418 491 125 148 176 208 272 322

662 777 932 1089 1427 1675 425 503 601 710 929 1099

1.20 1.19 1.23 1.23 1.24 1.24 1.20 1.19 1.23 1.23 1.24 1.24

5.54 6.2 7.89 8.92 12.07 13.67 5.76 6.23 7.92 8.96 12.12 13.72

3.6 4.1 5.2 5.9 8.0 9.1 3.6 4.1 5.2 5.9 8.0 9.1

200 300 300 400 500/400 600 150/120 150/120 200 300 300 400

VAL-SET-22-CR Thermostatic angled valve set, chrome plated. RRP (ex VAT) £67

£159

VAL-SET-23-CR Thermostatic straight valve set, chrome plated. RRP (ex VAT) £67

January 2019

49


TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Zehnder Charleston (page 24-29)

Zehnder Charleston (page 24-29)

Stock Models Model code

Made to Measure Options Height mm

Width mm

Finish

Overall Projection mm

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

Outputs Water Weight n ∆T=30K Content Exponent kg Watts Btu litres

Vertical 2180-6 1800 306 white/colour 90 length plus valves* 59 744 2539 381 2180-8 1800 398 white/colour 90 length plus valves* 59 992 3385 508 2180-10 1800 490 white/colour 90 length plus valves* 59 1240 4231 635 2180-12 1800 582 white/colour 90 length plus valves* 59 1488 5077 762 3180-6 1800 306 white/colour 128 length plus valves* 78 996 3398 510 3180-8 1800 398 white/colour 128 length plus valves* 78 1328 4531 680 3180-10 1800 490 white/colour 128 length plus valves* 78 1660 5664 850 Horizontal 2050-10 500 490 white/colour 90 length plus valves* 59 384 1310 203 2050-14 500 674 white/colour 90 length plus valves* 59 538 1836 284 2050-18 500 858 white/colour 90 length plus valves* 59 691 2358 365 2050-22 500 1042 white/colour 90 length plus valves* 59 845 2883 446 2050-26 500 1226 white/colour 90 length plus valves* 59 998 3405 527 2060-10 600 490 white/colour 90 length plus valves* 59 453 1546 239 2060-14 600 674 white/colour 90 length plus valves* 59 634 2163 335 2060-18 600 858 white/colour 90 length plus valves* 59 815 2781 430 2060-22 600 1042 white/colour 90 length plus valves* 59 997 3402 527 2060-24 600 1134 white/colour 90 length plus valves* 59 1080 3685 570 2060-28 600 1318 white/colour 90 length plus valves* 59 1260 4299 665 3050-14 500 674 white/colour 128 length plus valves* 78 722 2463 381 3050-18 500 858 white/colour 128 length plus valves* 78 929 3170 491 3050-22 500 1042 white/colour 128 length plus valves* 78 1135 3873 599 3050-26 500 1226 white/colour 128 length plus valves* 78 1342 4579 709 3050-30 500 1410 white/colour 128 length plus valves* 78 1548 5282 817 3060-10 600 490 white/colour 128 length plus valves* 78 609 2078 320 3060-14 600 674 white/colour 128 length plus valves* 78 853 2910 448 3060-18 600 858 white/colour 128 length plus valves* 78 1096 3740 576 128 length plus valves* 78 1220 4163 641 3060-20 600 950 white/colour 3060-24 600 1134 white/colour 128 length plus valves* 78 1464 4995 769 3060-27 600 1272 white/colour 128 length plus valves* 78 1645 5613 864 3060-30 600 1410 white/colour 128 length plus valves* 78 1827 6234 960 3060-34 600 1594 white/colour 128 length plus valves* 78 2071 7066 1088 3075-14 750 674 white/colour 128 length plus valves* 78 1040 3548 546 3075-22 750 1042 white/colour 128 length plus valves* 78 1635 5579 859 3075-26 750 1226 white/colour 128 length plus valves* 78 1932 6592 1015 4030-20 300 950 white/colour 164 length plus valves* 96 840 2866 444 4030-30 300 1410 white/colour 164 length plus valves* 96 1260 4299 665 4060-14 600 674 white/colour 164 length plus valves* 96 1117 3811 584 4060-18 600 858 white/colour 164 length plus valves* 96 1436 4900 751 4060-20 600 950 white/colour 164 length plus valves* 96 1600 5459 836 4060-24 600 1134 white/colour 164 length plus valves* 96 1920 6551 1004 4075-14 750 674 white/colour 164 length plus valves* 96 1364 4654 713 4075-18 750 858 white/colour 164 length plus valves* 96 1753 5981 916 4075-22 750 1042 white/colour 164 length plus valves* 96 2143 7312 1120 4075-26 750 1226 white/colour 164 length plus valves* 96 2532 8639 1323 *Nominal overall radiator length = (Number of sections x 46mm) + 26mm. Please see page 28 for manufacturing tolerances. Max. Working Pressure: 10 bar Test House: WSP-LAB Max. Working Temperature: 110°C Test House No: 2005

50

1300 1733 2167 2600 1740 2320 2900

1.31 1.31 1.31 1.31 1.31 1.31 1.31

16.4 21.9 27.3 32.8 24.6 32.8 41.0

9.0 12.0 15.0 18.0 14.0 19.0 24.0

693 969 1245 1522 1798 815 1143 1467 1798 1945 2269 1300 1675 2044 2419 2788 1092 1529 1965 2187 2624 2948 3276 3712 1863 2931 3463 1515 2269 1993 2562 2852 3426 2433 3125 3821 4514

1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.25 1.25 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27

7.9 11.0 14.2 17.4 20.5 9.5 13.3 17.1 20.9 22.8 26.6 16.6 21.4 26.2 30.9 35.7 13.9 19.4 24.9 27.7 33.2 37.3 41.6 47.0 24.3 38.2 45.1 21.3 32.0 27.3 35.1 39.0 46.8 33.6 43.2 52.8 62.5

5.0 7.0 9.0 11.0 13.0 6.0 8.4 10.8 13.2 14.4 16.8 11.2 14.4 17.6 20.8 24.0 9.0 12.6 16.2 18.0 21.6 24.3 27.0 30.6 15.4 24.2 28.6 14.0 21.0 16.8 21.6 24.0 28.8 19.6 25.2 30.8 36.4

Model code

Height mm

Finish

Overall Projection mm

Pipe Centres mm from wall radiator

Outputs ∆T=50K Watts Btu

Outputs Weight n ∆T=30K Exponent kg Watts Btu

2 column 2019 177 white/colour 90 length + valves* 59 14.5 49 7.6 26 2026 260 white/colour 90 length + valves* 59 21.1 72 11.1 38 2030 292 white/colour 90 length + valves* 59 23.6 80.52 12.5 42.65 2035 342 white/colour 90 length + valves* 59 27.5 94 14.5 49 2040 392 white/colour 90 length + valves* 59 31.2 106.45 16.6 56.64 2045 442 white/colour 90 length + valves* 59 34.9 119.08 18.5 63.12 2050 492 white/colour 90 length + valves* 59 38.4 131.02 20.3 69.26 2055 542 white/colour 90 length + valves* 59 41.9 142.96 22.1 75.41 2060 592 white/colour 90 length + valves* 59 45.3 154.56 23.9 81.55 2075 742 white/colour 90 length + valves* 59 55 187.66 29 98.95 2090 892 white/colour 90 length + valves* 59 63.9 218.03 33.7 114.98 2100 992 white/colour 90 length + valves* 59 69.5 237.13 36.7 125.22 2120 1192 white/colour 90 length + valves* 59 82.7 282.17 43.5 148.42 2150 1492 white/colour 90 length + valves* 59 104 354.85 54.1 184.59 2180 1792 white/colour 90 length + valves* 59 124 423.09 63.5 216.66 2200 1992 white/colour 90 length + valves* 59 138 470.86 70.7 241.23 3 column 3019 185 white/colour 128 length + valves* 78 20.1 69 10.5 36 128 length + valves* 78 3026 216 white/colour 27 92 14.6 50 3030 300 white/colour 128 length + valves* 78 32 109.18 16.9 57.66 3035 350 white/colour 128 length + valves* 78 37 126.24 19.5 66.53 3040 400 white/colour 128 length + valves* 78 41.9 142.96 22.1 75.41 3045 450 white/colour 128 length + valves* 78 46.8 159.68 24.7 84.28 3050 500 white/colour 128 length + valves* 78 51.6 176.06 27.2 92.81 3055 550 white/colour 128 length + valves* 78 56.3 192.10 29.6 101.00 3060 600 white/colour 128 length + valves* 78 60.9 207.79 32 109.18 3075 750 white/colour 128 length + valves* 78 74.3 253.51 39 133.07 3090 900 white/colour 128 length + valves* 78 87 296.84 45.5 155.25 3100 1000 white/colour 128 length + valves* 78 95.1 324.48 49.7 169.58 3120 1200 white/colour 128 length + valves* 78 115 392.38 59.5 203.01 3150 1500 white/colour 128 length + valves* 78 140 477.68 71.7 244.64 3180 1800 white/colour 128 length + valves* 78 166 566.39 84.1 286.95 183 624.40 92.8 316.63 3200 2000 white/colour 128 length + valves* 78 4 column 4019 200 white/colour 164 length + valves* 96 28.4 97 14.8 50 4026 260 white/colour 164 length + valves* 96 36.5 125 19.1 65 4030 300 white/colour 164 length + valves* 96 41.9 142.96 22.1 75.41 4035 350 white/colour 164 length + valves* 96 48.5 165.48 25.6 87.35 4040 400 white/colour 164 length + valves* 96 54.9 187.32 28.8 98.27 4045 450 white/colour 164 length + valves* 96 61.3 209.16 32.2 109.87 4050 500 white/colour 164 length + valves* 96 67.6 230.65 35.5 121.13 4055 550 white/colour 164 length + valves* 96 73.7 251.46 38.7 132.04 4060 600 white/colour 164 length + valves* 96 79.8 272.28 41.7 142.28 4075 750 white/colour 164 length + valves* 96 97.4 332.33 50.9 173.67 4090 900 white/colour 164 length + valves* 96 114 388.97 59.3 202.33 4100 1000 white/colour 164 length + valves* 96 125 426.50 64.7 220.76 4120 1200 white/colour 164 length + valves* 96 147 501.56 75.7 258.29 4150 1500 white/colour 164 length + valves* 96 180 614.16 92.2 314.59 4180 1800 white/colour 164 length + valves* 96 213 726.76 108 368.50 234 798.41 119.2 406.71 4200 2000 white/colour 164 length + valves* 96 5 column 5030 300 white/colour 202 length + valves* 115 51.7 176.40 27.3 93.15 5040 400 white/colour 202 length + valves* 115 67.9 231.67 35.7 121.81 5045 450 white/colour 202 length + valves* 115 75.8 258.63 39.8 135.80 5050 500 white/colour 202 length + valves* 115 83.5 284.90 43.6 148.76 5055 550 white/colour 202 length + valves* 115 91.1 310.83 47.6 162.41 5060 600 white/colour 202 length + valves* 115 98.6 336.42 51.5 175.72 5075 750 white/colour 202 length + valves* 115 120 409.44 62.1 211.89 5090 900 white/colour 202 length + valves* 115 141 481.09 72.6 247.71 5100 1000 white/colour 202 length + valves* 115 154 525.45 79.3 270.57 5120 1200 white/colour 202 length + valves* 115 179 610.75 91.7 312.88 219 747.23 111.6 380.78 5150 1500 white/colour 202 length + valves* 115 6 column 6030 300 white/colour 238 length + valves* 115 61.3 209.16 32.2 109.87 6035 350 white/colour 238 length + valves* 115 71 242.25 37.3 127.27 6040 400 white/colour 238 length + valves* 115 80.5 274.67 42.1 143.65 6045 450 white/colour 238 length + valves* 115 89.8 306.40 46.9 160.02 6050 500 white/colour 238 length + valves* 115 99 337.79 51.5 175.72 6055 550 white/colour 238 length + valves* 115 108 368.50 56.2 191.75 6060 600 white/colour 238 length + valves* 115 117 399.20 60.5 206.43 6075 750 white/colour 238 length + valves* 115 143 487.92 73.6 251.12 6090 900 white/colour 238 length + valves* 115 167 569.80 85.5 291.73 6100 1000 white/colour 238 length + valves* 115 183 624.40 93.7 319.70 6120 1200 white/colour 238 length + valves* 115 210 716.52 107 365.08 256 873.47 130.4 444.92 6150 1500 white/colour 238 length + valves* 115 *Nominal overall radiator length = (Number of sections x 46mm) + 26mm. Please see page 28 for manufacturing tolerances. Vertical entry = overall length minus 72mm Max. Working Pressure: 4 bar Test House: WSP-LAB Max. Working Temperature: 110°C Test House No: 1428

Water Content litres

1.26 1.25 1.24 1.24 1.24 1.24 1.25 1.25 1.25 1.25 1.25 1.25 1.26 1.28 1.31 1.31

0.32 0.44 0.5 0.57 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.9 2.3 2.7 3.0

0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.1 1.3 1.5 1.7

1.27 1.25 1.25 1.25 1.25 1.25 1.25 1.26 1.26 1.26 1.27 1.27 1.29 1.31 1.33 1.33

0.49 0.66 0.7 0.9 1.0 1.1 1.2 1.3 1.4 1.7 2.1 2.3 2.8 3.4 4.1 4.5

0.4 0.5 0.6 0.6 0.7 0.7 0.8 0.9 0.9 1.1 1.3 1.4 1.6 2.0 2.4 2.6

1.26 1.25 1.25 1.25 1.26 1.26 1.26 1.26 1.27 1.27 1.28 1.29 1.30 1.31 1.33 1.32

0.67 0.84 1.0 1.2 1.4 1.5 1.7 1.9 2.0 2.5 2.9 3.2 3.7 4.4 5.2 5.8

0.6 0.7 0.7 0.8 0.9 1.0 1.0 1.1 1.2 1.4 1.7 1.8 2.1 2.6 3.1 3.4

1.25 1.26 1.26 1.27 1.27 1.27 1.29 1.30 1.30 1.31 1.32

1.3 1.7 1.9 2.1 2.3 2.5 3.1 3.6 3.9 4.6 5.6

0.9 1.1 1.2 1.3 1.4 1.5 1.8 2.1 2.3 2.7 3.3

1.26 1.26 1.27 1.27 1.28 1.28 1.29 1.30 1.31 1.31 1.32 1.32

1.6 1.8 2.0 2.2 2.4 2.7 2.9 3.5 4.2 4.6 5.5 6.8

1.1 1.2 1.3 1.4 1.5 1.6 1.8 2.1 2.5 2.7 3.2 4.0

January 2019

51


TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Zehnder Klaro (page 12)

Zehnder Lyta-T (page 34)

Stock Models Model code

Stock Models Height mm

Width mm

ZSL-080-045 748 450 ZSL-120-050 1148 500 ZSL-120-060 1148 600 ZSL-150-050 1466 500 ZSL-150-060 1466 600 ZSL-170-050 1708 500 ZSL-170-060 1708 600 Max. Working Pressure: 4 bar Max. Working Temperature: 110°C

Finish

Overall Projection mm

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 white/colour 87 to 102 Test House: HLK STUTTGART Test House No: 0626

412 462 562 462 562 462 562

68 to 83 68 to 83 68 to 83 68 to 83 68 to 83 68 to 83 68 to 83

354 571 670 716 839 824 966

1208 1948 2286 2443 2863 2811 3296

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 187 298 352 372 436 424 502

638 1017 1201 1269 1488 1447 1713

1.25 1.27 1.26 1.28 1.28 1.30 1.28

5.4 8.7 9.8 10.9 12.3 12.2 14.2

3.6 5.8 6.6 7.4 8.5 8.5 9.6

200 400 500/400 500/400 500/400 500/400 600

Model code

Height mm

Width mm

LYTV-Z-097-032 966 320 LYTV-Z-097-048 966 480 LYTV-Z-147-032 1466 320 LYTV-Z-147-048 1466 480 LYTV-Z-187-024 1866 240 LYTV-Z-187-032 1866 320 LYTV-Z-187-040 1866 400 LYTV-Z-187-048 1866 480 *white (RAL 9010) Max. Working Pressure: 6 bar Max. Working Temperature: 120°C

Finish

Overall Projection mm

white* white* white* white* white* white* white* white*

110 to 140 110 to 140 110 to 140 110 to 140 110 to 140 110 to 140 110 to 140 110 to 140

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 344 plus valves 504 plus valves 344 plus valves 504 plus valves 264 plus valves 344 plus valves 424 plus valves 504 plus valves

82 82 82 82 82 82 82 82

728 1092 1000 1500 900 1200 1500 1800

Outputs Water Weight n ∆T=30K Content Exponent kg Watts Btu litres

2484 3726 3412 5118 3071 4094 5118 6142

362 542 499 749 442 590 737 885

1234 1851 1703 2555 1510 2013 2516 3019

1.37 1.37 1.39 1.39 1.39 1.39 1.39 1.39

7.8 11.8 11.2 16.8 10.2 13.6 17.0 20.4

1.7 2.6 2.5 3.7 2.3 3.1 3.9 4.7

Test House: Laboratorio Misure Ricerche Termotecniche Test House No: 1695

Zehnder Kleo (page 30) Stock Models Model code

Height mm

Width mm

Vertical KLV-180-030 1800 299 KLV-180-040 1800 398 KLV-180-050 1800 497 KLV-180-060 1800 596 KLVC-180-030 1800 299 KLVC-180-040 1800 398 KLVC-180-050 1800 497 KLVC-180-060 1800 596 Horizontal KLH-058-100 596 1000 KLH-058-120 596 1200 KLH-058-140 596 1400 KLHD-058-100 596 1000 KLHD-058-120 596 1200 KLHD-058-140 596 1400 Max. Working Pressure: 4 bar Max. Working Temperature: 110°C

Finish

white/colour white/colour white/colour white/colour chrome chrome chrome chrome

Overall Projection mm

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

Outputs Weight n ∆T=30K Exponent kg Watts Btu

Water Content litres

74 74 74 74 74 74 74 74

248 347 446 545 248 347 446 545

38 38 38 38 38 38 38 38

632 842 1053 1264 448 598 747 896

2156 2874 3593 4313 1529 2040 2549 3057

329 438 548 647 225 300 375 450

1123 1494 1870 2209 768 1024 1280 1535

1.28 1.28 1.28 1.28 1.35 1.35 1.35 1.35

10.8 14.4 18.0 21.6 10.8 14.4 18.0 21.6

4.5 6.1 7.5 9.0 4.5 6.1 7.5 9.0

white/colour 74 white/colour 74 white/colour 74 white/colour 106 white/colour 106 white/colour 106 Test House: CETIAT Test House No: 1623

962 1162 1362 962 1162 1362

38 38 38 38 38 38

782 938 1095 1211 1453 1695

2668 3201 3736 4134 4961 5787

413 495 578 636 763 891

1409 1689 1972 2170 2603 3040

1.25 1.25 1.25 1.26 1.26 1.26

12.7 14.9 17.1 22.6 27.1 31.6

5.5 6.6 7.7 12.5 15.0 17.5

Zehnder Muralis (page 14) Stock Models Model code

Height mm

Width mm

MUR-080-050-0346 800 500 MUR-100-050-0346 1000 500 MUR-120-050-0346 1200 500 MUR-140-050-0346 1400 500 MUR-160-050-0346 1600 500 MURC-080-050 800 500 MURC-100-050 1000 500 MURC-120-050 1200 500 MURC-140-050 1400 500 MURC-160-050 1600 500 Max. Working Pressure: 4 bar Max. Working Temperature: 120°C

Finish

Overall Projection mm

anthracite 80 anthracite 80 anthracite 80 anthracite 80 anthracite 80 chrome 80 chrome 80 chrome 80 chrome 80 chrome 80 Test House: WSP LAB Test House No: 1428

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 470 470 470 470 470 470 470 470 470 470

65-90 65-90 65-90 65-90 65-90 65-90 65-90 65-90 65-90 65-90

306 384 461 537 612 197 249 301 346 391

1044 1310 1573 1832 2088 672 850 1027 1181 1334

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 164 204 245 284 324 103 130 156 179 202

558 697 835 971 1107 351 442 534 612 690

1.20 1.21 1.22 1.22 1.22 1.25 1.26 1.26 1.26 1.27

5.6 7.0 8.4 9.6 10.9 5.5 7.0 8.4 9.6 10.8

3.30 4.10 4.90 5.70 6.40 3.30 4.10 4.90 5.70 6.40

200/200 200/200 300/300 300/300 400/400 150/120 200/200 200/200 200/200 300/300

Zehnder Lyta-S (page 32) Stock Models Model code

Height mm

Width mm

LYSV-Z-040-048 395 480 LYSV-Z-040-064 395 640 LYSV-Z-040-080 395 800 LYSV-Z-040-096 395 960 LYSV-Z-040-112 395 1120 LYSV-Z-055-048 545 480 LYSV-Z-055-064 545 640 LYSV-Z-055-080 545 800 LYSV-Z-055-096 545 960 LYSV-Z-055-112 545 1120 LYSV-Z-065-048 645 480 LYSV-Z-065-064 645 640 LYSV-Z-065-080 645 800 LYSV-Z-065-096 645 960 LYSV-Z-065-112 645 1120 *white (RAL 9010) Max. Working Pressure: 24 bar Max. Working Temperature: 120°C

52

Finish

Overall Projection mm

white* white* white* white* white* white* white* white* white* white* white* white* white* white* white*

130 130 130 130 130 130 130 130 130 130 130 130 130 130 130

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu 504 plus valves 664 plus valves 824 plus valves 984 plus valves 1144 plus valves 504 plus valves 664 plus valves 824 plus valves 984 plus valves 1144 plus valves 504 plus valves 664 plus valves 824 plus valves 984 plus valves 1144 plus valves

82 82 82 82 82 82 82 82 82 82 82 82 82 82 82

546 728 910 1092 1274 737 983 1229 1475 1721 848 1131 1414 1697 1980

1863 2484 3105 3726 4347 2516 3355 4193 5032 5871 2895 3860 4824 5789 6754

Outputs Water Weight n ∆T=30K Content Exponent kg Watts Btu litres 283 377 471 565 659 381 509 636 763 890 435 581 726 871 1016

964 1286 1607 1929 2250 1302 1736 2170 2604 3038 1486 1982 2477 2973 3468

1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.29 1.30 1.30 1.30 1.30 1.30

6.6 8.8 11.0 13.2 15.4 8.4 11.2 14.0 16.8 19.6 9.6 12.8 16.0 19.2 22.4

1.44 1.92 2.40 2.88 3.36 1.5 2.0 2.5 3.0 3.5 1.8 2.4 3.0 3.6 4.2

Test House: Laboratorio Misure Ricerche Termotecniche Test House No: 1695

January 2019

53


TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Zehnder Roda (page 36)

Zehnder Roda (page 38)

Stock Models Model code

Made to Measure Options Height mm

Width mm

Finish

Overall Projection mm

Zehnder Roda vertical single panel ROV-180-029 1800 296 white/colour 70 ROV-180-037 1800 370 white/colour 70 ROV-180-044 1800 444 white/colour 70 ROV-180-051 1800 518 white/colour 70 ROV-180-059 1800 592 white/colour 70 ROV-180-066 1800 666 white/colour 70 Zehnder Roda vertical double panel ROVD-180-029 1800 296 white/colour 93 ROVD-180-037 1800 370 white/colour 93 ROVD-180-044 1800 444 white/colour 93 ROVD-180-051 1800 518 white/colour 93 ROVD-180-059 1800 592 white/colour 93 ROVD-180-066 1800 666 white/colour 93 Zehnder Roda horizontal single panel ROH-052-100 518 1000 white/colour 70 ROH-052-120 518 1200 white/colour 70 ROH-059-080 592 800 white/colour 70 ROH-059-100 592 1000 white/colour 70 ROH-059-120 592 1200 white/colour 70 ROH-059-140 592 1400 white/colour 70 Zehnder Roda horizontal single panel with single convector fin ROHL-052-100 518 1000 white/colour 70 ROHL-052-120 518 1200 white/colour 70 ROHL-059-060 592 600 white/colour 92 ROHL-059-080 592 800 white/colour 92 ROHL-059-100 592 1000 white/colour 92 ROHL-059-120 592 1200 white/colour 92 ROHL-059-140 592 1400 white/colour 70 ROHL-059-160 592 1600 white/colour 70 Zehnder Roda horizontal double panel ROHD-059-060 592 600 white/colour 93 ROHD-059-080 592 800 white/colour 93 ROHD-059-100 592 1000 white/colour 93 ROHD-059-120 592 1200 white/colour 93 Max. Working Pressure: 4 bar Test House: CETIAT Max. Working Temperature: 110°C Test House No: 1623

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

Outputs n Weight ∆T=30K Exponent kg Watts Btu

Water Content litres

42 42 42 42 42 42

568 710 852 994 1136 1278

1940 2425 2910 3395 3880 4365

291 364 436 509 582 654

993 1242 1488 1737 1986 2231

1.31 1.31 1.31 1.31 1.31 1.31

12 15 18 21 24 27

4.6 5.75 6.9 8.05 9.2 10.35

247 321 395 469 543 617

66 66 66 66 66 66

824 1030 1236 1442 1648 1854

2812 3515 4218 4921 5624 6327

420 525 630 735 840 945

1433 1791 2150 2508 2866 3224

1.32 1.32 1.32 1.32 1.32 1.32

22.4 28 33.6 39.2 44.8 50.4

8.6 10.75 12.9 15.05 17.2 19.35

932 1132 732 932 1132 1332

42 42 42 42 42 42

586 703 532 665 798 931

1999 2399 1815 2269 2723 3177

305 366 277 346 415 484

1041 1249 945 1181 1416 1651

1.28 1.28 1.28 1.28 1.28 1.28

13.4 16.1 11.39 14.1 18.1 19.7

4.9 5.88 4.48 5.6 6.72 7.84

932 1132 532 732 932 1132 1332 1532

62 62 62 62 62 62 62 52

3163 3794 636 848 1060 1272 1504 1718

491 589 2170 2894 3617 4340 5132 5862

491 589 334 446 557 668 792 905

1675 2010 1140 1522 1900 2279 2702 3088

1.24 1.24 1.26 1.26 1.26 1.26 1.26 1.26

18 21.59 13.2 17.6 22 26.4 30.72 35.1

4.9 5.88 3.36 4.48 5.6 6.72 7.85 8.96

532 732 932 1132

66 66 66 66

641 855 1069 1283

2187 2916 3645 4374

337 449 562 674

1150 1532 1918 2300

1.26 1.26 1.26 1.26

16.5 22 27.4 32.9

6.04 8.05 10.06 12.07

ROHL-014

Finish

Overall Projection mm

Pipe Centres mm radiator from wall

Zehnder Roda ROV single, data per vertical tube ROV-060 600 white/colour 70 length minus 49 ROV-080 800 white/colour 70 length minus 49 ROV-100 1000 white/colour 70 length minus 49 ROV-120 1200 white/colour 70 length minus 49 ROV-140 1400 white/colour 70 length minus 49 ROV-160 1600 white/colour 70 length minus 49 ROV-180 1800 white/colour 70 length minus 49 ROV-200 2000 white/colour 70 length minus 49 ROV-220 2200 white/colour 70 length minus 49 Zehnder Roda ROVD double, data per vertical tube ROVD-060 600 white/colour 93 length minus 49 ROVD-080 800 white/colour 93 length minus 49 ROVD-100 1000 white/colour 93 length minus 49 ROVD-120 1200 white/colour 93 length minus 49 ROVD-140 1400 white/colour 93 length minus 49 ROVD-160 1600 white/colour 93 length minus 49 ROVD-180 1800 white/colour 93 length minus 49 ROVD-200 2000 white/colour 93 length minus 49 ROVD-220 2200 white/colour 93 length minus 49 To calculate the number of tubes required, allow 74mm per tube Max. Working Pressure: 4 bar Test House: CETIAT Max. Working Temperature: 110°C Test House No: 1623

54

Finish

Overall Projection mm

Pipe Centres mm radiator from wall

Outputs ∆T=50K Watts Btu

Outputs Weight n ∆T=30K Exponent kg Watts Btu

Water Content litres

Outputs ∆T=50K Watts Btu

Outputs Weight n ∆T=30K Exponent kg Watts Btu

length minus 68

62

350

1194

195

665

1.15

7.0

1.40

ROHL-022 222 white/colour 92 length minus 68 ROHL-030 296 white/colour 92 length minus 68 ROHL-037 370 white/colour 92 length minus 68 ROHL-044 444 white/colour 92 length minus 68 ROHL-052 518 white/colour 92 length minus 68 ROHL-060 592 white/colour 92 length minus 68 ROHL-067 666 white/colour 92 length minus 68 ROHL-074 740 white/colour 92 length minus 68 Zehnder Roda ROH single, data per linear metre ROH-030 296 white/colour 70 length minus 68 ROH-037 370 white/colour 70 length minus 68 ROH-044 444 white/colour 70 length minus 68 ROH-052 518 white/colour 70 length minus 68 ROH-060 592 white/colour 70 length minus 68 ROH-067 666 white/colour 70 length minus 68 ROH-074 740 white/colour 70 length minus 68 Max. Working Pressure: 4 bar Test House: CETIAT Max. Working Temperature: 110°C Test House No: 1623

148

white/colour

92

62 62 62 62 62 62 62 62

511 637 719 845 927 1060 1157 1237

1744 2173 2453 2883 3163 3617 3945 4218

268 334 374 448 492 558 608 650

914 1140 1276 1529 1679 1904 2073 2217

1.26 1.27 1.28 1.24 1.24 1.26 1.26 1.26

10.7 14.3 16.1 18.7 19.5 23.6 24.7 26.5

2.10 2.80 3.50 4.20 4.90 5.60 6.3 7.0

42 42 42 42 42 42 42

344 425 506 586 665 744 823

1174 1450 1726 1999 2269 2537 2806

179 221 264 305 347 387 428

611 754 901 1041 1184 1320 1459

1.28 1.28 1.28 1.28 1.28 1.28 1.28

7.2 9.0 10.7 12.4 14.1 16.0 17.8

2.80 3.50 4.20 4.90 5.60 6.3 7.0

Zehnder Stana (page 40) Stock Models Model code

Made to Measure Options Height mm

Height mm

Zehnder Roda ROHL single with convector fins, data per linear metre 247 321 395 469 543 617

Zehnder Roda (page 38) Model code

Model code

Water Content litres

42 42 42 42 42 42 42 42 42

52 68 83 98 113 127 142 155 169

177 232 283 334 386 433 485 529 577

26 34 42 50 58 65 73 80 87

89 116 143 171 198 222 249 273 297

1.30 1.55 1.32 1.32 1.31 1.31 1.31 1.31 1.31

1.3 1.6 1.9 2.1 2.4 2.7 3.0 3.3 3.6

0.5 0.6 0.7 0.8 0.9 1.0 1.2 1.3 1.4

66 66 66 66 66 66 66 66 66

77 100 122 144 165 186 206 225 244

263 341 416 491 563 635 703 768 833

39 51 62 73 84 95 105 115 124

133 174 212 249 287 324 358 392 423

1.33 1.33 1.33 1.33 1.33 1.32 1.32 1.32 1.32

2.1 2.7 3.3 3.9 4.4 5.0 5.6 6.2 6.7

0.8 1.0 1.3 1.5 1.7 1.9 2.2 2.4 2.6

Height mm

Width mm

STN-015-014-100 250 1000 STN-015-014-120 250 1200 STN-015-014-140 250 1400 STN-015-014-150 250 1500 STN-015-014-160 250 1600 STN-015-014-200 250 2000 STN-015-020-100 250 1000 STN-015-020-120 250 1200 STN-015-020-140 250 1400 STN-015-020-150 250 1500 STN-015-020-160 250 1600 STN-015-020-200 250 2000 Max. Working Pressure: 10 bar Max. Working Temperature: 110°C

Depth mm 140 140 140 140 140 140 200 200 200 200 200 200

Finish

Overall Pipe Centres mm projection radiator (mm)

9016 140 9016 140 9016 140 9016 140 9016 140 9016 140 9016 200 9016 200 9016 200 9016 200 9016 200 9016 200 Test House: WSP-LAB Test House No: 1428

50 50 50 50 50 50 50 50 50 50 50 50

Outputs ∆T=50K Watts Btu 625 750 875 938 1000 1250 993 1192 1390 1490 1589 1986

2133 2559 2986 3200 3412 4265 3388 4067 4743 5084 5422 6776

Outputs ∆T=30K Watts Btu 304 365 425 456 486 608 474 569 664 711 758 948

1037 1245 1450 1556 1658 2074 1617 1941 2266 2426 2586 3235

Weight kg 11.7 14 16.4 17.6 18.7 23.4 14.2 17 19.9 21.3 22.7 28.4

Water Content litres 1 1.3 1.6 1.7 1.8 2.3 1.7 2.1 2.5 2.7 2.9 3.8

January 2019

55


TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Zehnder Stellar (page 16)

Zehnder Zeta (page 20)

Stock Models Model code

Stock Models Height mm

Width mm

STNI-060-045 572 450 STNI-060-100 572 1000 STNI-080-030 788 300 STNI-080-045 788 450 STNI-080-060 788 600 STNI-120-030 1220 300 STNI-120-045 1220 450 STNI-120-060 1220 600 STNI-150-045 1508 450 STNI-150-060 1508 600 STNI-170-045 1724 450 STNI-170-060 1724 600 STNI-060-045-CF 572 450 STNI-060-100-CF 572 1000 STNI-080-030-CF 788 300 STNI-080-045-CF 788 450 STNI-080-060-CF 788 600 STNI-120-030-CF 1220 300 STNI-120-045-CF 1220 450 STNI-120-060-CF 1220 600 STNI-150-045-CF 1508 450 STNI-150-060-CF 1508 600 STNI-170-045-CF 1724 450 STNI-170-060-CF 1724 600 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C

Finish

Overall Projection mm

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 Test House: HLK STUTTGART Test House No: 0626

420 970 270 420 570 270 420 570 420 570 420 570 420 970 270 420 570 270 420 570 420 570 420 570

75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85

159 284 159 206 253 242 316 391 389 491 452 545 233 430 232 317 395 353 482 600 591 736 672 838

541 970 541 702 863 826 1078 1334 1327 1675 1542 1860 795 1467 792 1082 1348 1204 1645 2047 2016 2511 2293 2859

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 84 152 85 109 135 129 166 208 206 258 241 288 125 231 124 170 212 188 258 322 315 393 359 449

287 519 290 372 459 440 567 710 703 882 822 983 426 787 424 580 723 643 882 1098 1076 1340 1223 1533

1.24 1.22 1.23 1.24 1.23 1.23 1.26 1.24 1.24 1.26 1.23 1.25 1.22 1.23 1.23 1.22 1.22 1.23 1.23 1.22 1.23 1.23 1.23 1.23

3.3 5.8 3.6 4.5 5.4 5.5 6.9 8.4 8.5 10.2 10.0 12.0 3.3 5.8 3.6 4.5 5.4 5.5 6.9 8.4 8.5 10.2 10.0 12.0

2.0 3.6 2.2 2.8 3.4 3.5 4.3 5.2 5.1 6.2 6.1 7.2 2.0 3.6 2.2 2.8 3.4 3.5 4.3 5.2 5.1 6.2 6.1 7.2

100/n/a 200 100/n/a 150/120 150/120 150/120 150/120 200 300 300 300 400 100/n/a 200 100/n/a 150/120 150/120 150/120 150/120 200 300 300 300 400

Model code

Height mm

Width mm

PQ6-080-050 800 500 PQ6-120-050 1200 500 PQ6-160-050 1600 500 PQ6-080-050-0346 800 500 PQ6-120-050-0346 1200 500 PQ6-160-050-0346 1600 500 PQ6C-080-050 800 500 PQ6C-080-060 800 600 PQ6C-120-050 1200 500 PQ6C-120-060 1200 600 PQ6C-160-050 1600 500 PQ6C-160-060 1600 600 Max. Working Pressure: 4 bar Max. Working Temperature: 120°C

Finish

Overall Projection mm

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

white 81 white 81 white 81 anthracite 81 anthracite 81 anthracite 81 chrome 81 chrome 81 chrome 81 chrome 81 chrome 81 chrome 81 Test House: HLK STUTTGART Test House No: 0626

468 468 468 468 468 468 468 568 468 568 468 568

65 65 65 65 65 65 65 65 65 65 65 65

324 476 647 324 476 647 203 235 302 350 395 457

1105 1624 2208 1105 1624 2208 689 792 1034 1204 1344 1559

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 172 253 345 172 253 345 107 124 157 184 206 239

587 863 1177 587 863 1177 365 423 536 628 703 815

1.24 1.24 1.23 1.24 1.24 1.23 1.26 1.25 1.28 1.26 1.27 1.27

6.4 10.1 13.3 6.4 10.1 13.3 6.4 7.4 10.0 11.4 13.2 15.3

2.2 3.7 4.6 2.2 3.7 4.6 2.2 2.6 3.7 4.4 4.6 5.5

200 300 400 200 300 400 200 200 300 400 400 400

Zehnder Stellar Spa (page 18) Stock Models Model code

Height mm

Width mm

STGI-060-045 572 450 STGI-060-100 572 1000 STGI-080-030 788 300 STGI-080-045 788 450 STGI-080-060 788 600 STGI-120-030 1220 300 STGI-120-045 1220 450 STGI-120-060 1220 600 STGI-150-045 1508 450 STGI-150-060 1508 600 STGI-170-045 1724 450 STGI-170-060 1724 600 STGI-060-045-CF 572 450 STGI-060-100-CF 572 1000 STGI-080-030-CF 788 300 STGI-080-045-CF 788 450 STGI-080-060-CF 788 600 STGI-120-030-CF 1220 300 STGI-120-045-CF 1220 450 STGI-120-060-CF 1220 600 STGI-150-045-CF 1508 450 STGI-150-060-CF 1508 600 STGI-170-045-CF 1724 450 STGI-170-060-CF 1724 600 Max. Working Pressure: 10 bar Max. Working Temperature: 120°C

56

Finish

Overall Projection mm

Pipe Centres Outputs mm ∆T=50K radiator from wall Watts Btu

s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 s/steel finish 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 painted 90 to 100 Test House: HLK STUTTGART Test House No: 0626

420 970 270 420 570 270 420 570 420 570 420 570 420 970 270 420 570 270 420 570 420 570 420 570

75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85 75 to 85

161 272 171 220 243 240 309 379 361 448 434 517 219 394 218 294 363 332 448 554 556 687 640 791

549 928 583 751 829 819 1054 1293 1232 1529 1481 1764 747 1344 744 1003 1239 1133 1529 1890 1897 2344 2184 2699

Outputs Water Max. Weight n ∆T=30K Content Immersion Exponent kg Watts Btu litres Rating 84 144 89 115 128 125 161 197 187 233 226 270 117 211 117 158 194 177 239 294 297 367 343 422

287 491 304 392 435 427 549 672 639 795 771 921 401 721 399 538 661 604 815 1003 1012 1251 1171 1440

1.27 1.24 1.28 1.27 1.26 1.28 1.28 1.28 1.28 1.28 1.28 1.27 1.23 1.23 1.23 1.23 1.23 1.23 1.24 1.24 1.24 1.24 1.23 1.23

3.1 5.3 3.4 4.2 5.0 5.2 6.5 7.7 7.8 9.3 9.4 11.2 3.1 5.3 3.4 4.2 5.0 5.2 6.5 7.7 7.8 9.3 9.4 11.2

1.8 3.0 2.0 3.0 3.2 3.1 3.9 4.6 4.7 5.6 5.3 6.5 1.8 3.0 2.0 3.0 3.2 3.1 3.9 4.6 4.7 5.6 5.3 6.5

100 150/120 100 100 150/120 150/120 150/120 200 300 300 200 300 100/n/a 150/120 100/n/a 100/n/a 150/120 150/120 150/120 200 300 300 200 300

January 2019

57


Charleston Technoline Finish Everything you need to know... Typically the four column radiator would look as below.

Zehnder Charleston in Technoline finish essentially shows unique colour and surface appearance for each radiator. This is due to different manufacturing processes and welding technologies (LaZer welding for the headers and projection welding or soldering for the header-tube connection), so each radiator is one of a kind! Header: Marks at the top of the header Occurrence: On each header / on some headers Height: For all heights Reason for appearance: Securing of the sections during welding processes

Header: LaZer welding - silver coloured Header Tube Connection: Projection welding - visible grinding marks Occurrence: 2-6 Columns Height: 400mm or over Reason for appearance: LaZer and projection welding technology

Typically the two column radiator would look as above.

Header: Silver coloured Header Tube Connection: Soldering – darker coloured (brown/blue) Occurrence: 2-6 columns Height: 400mm or under Reason for the appearance: Soldering

Header: Silver coloured Header Tube Connection: Scratches on the radiator visible beneath the clear lacquer Occurrence: On each section / on some sections /on no section Reason for the appearance: Pre-exisitng scratches on the delivered raw material / securing of the sections during welding processes

Typically the four column, under 400m in height radiator would look as below.

Header: LaZer welding seam is visible on the side Header Tube Connection: Projection welding - silver coloured Occurrence: On each section / on some sections / on no section Height: 400mm or over Reason for appearance: The seam is due to the laZer welding process

58

Typically the three column radiator would look as above.

January 2019

59


Charleston LaZer made, the high-tech, residue-free welding method The fact that Zehnder Charleston has become a radiator classic is not surprising due to its impressive innovation. Even today it boasts a unique new feature: the manufacturing of Zehnder Charleston with LaZer made. This innovative laser welding method for the production of sectional radiators is setting new standards for quality and technology in terms of precision, quality and functionality. Thanks to LaZer made, manufacturing can be more precise than ever before – all without residues inside the radiator or offsets on its surfaces. This makes for an even more attractive appearance and optimised radiator operation. For more benefits, see the information on the right.

Smooth operation, less hassle

The application of this new laser welding method ensures completely clean welding. It guarantees that absolutely no residues remain inside the radiator – this prevents the valves and heat generators from potentially becoming blocked. For you, this means reliable operation and less time required to flush out the heating system. Old

New

Top quality, enhanced appearance

Continuous inspection by a 3D co-ordinate measuring machine prevents even the smallest dimensional nonconformities. To ensure absolute tightness, each unfinished structure is subjected to testing in a test bath both during the production process and in the final stage of manufacturing. The unique production method enables leakproof radiators and clean contours free of offsets. The resulting smooth surfaces are easier to clean.

Sustainable manufacturing, made in Germany Improved energy efficiency, environmental friendliness and sustainability. Because the new laser welding technology requires less energy than the previous method, Zehnder Charleston boasts a satisfyingly low CO2 footprint. With the “made in Germany” manufacturing label, Zehnder is dedicated to its production site in Lahr as well as to short transportation distances and ensured sustainability.

More efficient processes, even faster and more reliable delivery

Tube machining is performed directly on the automatically delivered tube bundles. This removes the need for any interruptions between the production stages and speeds up the manufacturing process. Your radiators are therefore delivered to your project site even faster and are guaranteed to arrive on the agreed date.

3

WEEKS

Scan the QR code to watch the Zehnder LaZer welding made process

60

January 2019

61


Colour System

ystem Colour System

al

Natural Natural

Architectural Architectural

White Quartz Matt White 0521 0556 - Matt

Pure White White Quartz 9210 - Matt 0521 9010 - Glossy

Pure White Look Aluminium 9210 - Matt 9551* 9010 - Glossy

Inox Look Look Aluminium 0332 - Glossy 9551*

Inox Look 0332 - Glossy

Edelweiss 0067 - Matt

Cream 9201 - Matt 9001 - Glossy

Pergamon 0281 - Matt 0081- Glossy

Jasmin 0072 - Matt

Oyster White 1213 - Matt 1013 - Gloss

Titane White Aluminium 0335 9206 - Matt 9006 - Glossy

Titane Grey Aluminium 0335 9207 - Matt 9007 - Glossy

Anthracite Grey Aluminium 0346 9207 - Matt 9007 - Glossy

Volcanic Anthracite 0336 0346

Volcanic 0336

Grey White 9202 - Matt 9002 - Glossy

Chinchilla 0064 - Matt

Manhattan 0277 - Mat 0077 - Glossy

Natura 0235 - Matt 0035 - Glossy

Bahama 0254 - Matt 0054 - Glossy

Traffic Anthracite Black Grey 9217 7216 - Matt 9017 7016 -- Glossy Glossy

Traffic Black Jet Black 9217 9205 - Matt 9017 9005 -- Glossy Glossy

Jet Black Matt Black 9205 - Matt Matt 0557 9005 - Glossy

BlackBlack Quartz Matt 0550 - Matt 0557

Black Quartz 0550

Petal 0510 - Glossy

Sand Quartz 0522

Beige Quartz 0523

Caramel Quartz 0511

Terracotta Quartz 0512

Gold Look 0514

Brown Quartz 0529

Dark Brown 0847 - Matt

Chocolate Brown 8217 - Matt 8017 - Glossy

Tonic Tonic

Traffic LemonYellow 1223 0515 - Matt Glossy 1023 - Glossy

Traffic OrangeYellow Quartz 1223 0528 - Matt 1023 - Glossy

Flame Red Orange Quartz 3200 0528 - Matt 3000 - Glossy

FlameRed Red Ruby 3200 - Matt 3203 3000 - Glossy 3003

Ruby Red 3203 - Matt 3003 - Glossy

Standard Standard

Surfaces Surfaces

Mauve Violet 0517 - Glossy 0518

Violet Strawberry 0518 3770 - Glossy Matt 3470 - Glossy

Dark Purple Strawberry 0848 - Matt 3770 Matt 3470 - Glossy

Amethyst Quartz Dark Purple 0516 - Matt 0848

Amethyst Quartz 0516

Traffic White 9216 - Matt (Incurs +25% colour surcharge) 9016 - Glossy

Inox Chrome 0008

Chrome Steel Stainless 0008 available for Only stainless steel radiators

Technoline (Clear) 0325*

Technoline (Clear) Bare-metal lacquer glossy finish 0325. Only available for Charleston range White Matt excluding NZ-030-100. RAL 9016 on Information manufacturers’ marks see page 58.

Black-silver hammered finish 0422. Only available for Charleston range Volcanic 0336

Copper-black hammered finish 0421. Only available for Charleston range

Planus Surface

Spring Lichen Green 0846 8723 -- Matt Matt 8423 - Glossy

Spring Pacific Green Blue 0846 0519 - Matt

HorizonBlue Blue Pacific 0520 - Matt Glossy 0519

PrussianBlue Blue Horizon 0555 - Glossy 0520

Prussian Blue 0555 - Glossy Grey Aluminium 9207 - Matt 9007 - Glossy

Some colours/surface finishes are only available for selected products.

Grey Aluminium with Serigrafie RAL 9007

Deviations are possible (shade and shine) due to the different manufacturing techniques used for the original colours. RAL and NCS are manufacturer designations.

nishes are onlySome available colours/surface for selectedfinishes products. are only available for selected products.

This colour chart only represents the range of Zehnder colours available. It is not representative of the actual colour finish.

Please for a manufacturing colour from which to confirm your before placing order. (shade and shine) Deviations due to ask are the possible different (shade andchart shine) techniques due to the used different for the manufacturing original colours. techniques RAL selection and used NCS for arethe manufacturer original colours. designations. RALyour and NCS are manufacturer designations. 62 2

January 2019 Colour System

633


General Information

Notes

Heat Loss Calculator

Frequently Asked Questions

This easy-to-use heat calculator can work out the heat requirements for your room. Stage 1 Take the room dimensions in metres Width

m

Length

m

Height

m

cubic metres

calculate the volume (W x L x H) =

Stage 2 Heating requirements per room type volume

Living Room / Dining Room / Bathroom multiply volume as calculated in Stage 1 by 50 = Bedroom

multiply volume as calculated in Stage 1 by 40 = Kitchen / Hallway

Watts required

volume Watts required

volume

multiply volume as calculated in Stage 1 by 30 =

Watts required

Why is it important with some of the models that the flow is in a specific connection position? Some of the design radiators have baffles inside the water-carrying tubes to divert the water flow around the whole radiator to maximize efficiency. Check the installation instructions to see if this applies to the radiator before it is installed.

Stage 3 Other factors for consideration Is the property exposed? a Does the room have large areas of glazing? b Are the windows double glazed? c If factor ‘a’ applies, increase the Watts required at Stage 2 by 15% If factor ‘b’ applies, increase the Watts required at Stage 2 by 20% If factor ‘c’ applies, decrease the Watts required at Stage 2 by 10% If factor ‘a’ and ‘b’ apply, increase the Watts required at Stage 2 by 35% If factor ‘a’ and ‘c’ apply, increase the Watts required at Stage 2 by 5% If factor ‘b’ and ‘c’ apply, increase the Watts required at Stage 2 by 10% If factor ‘a’, ‘b’ and ‘c’ apply, increase the Watts required at Stage 2 by 25% Please note that this calculator is provided as a guide only. To convert Watts to BTUs, multiply by 3.412. For an approximate conversion from ∆T50°C to ∆T60°C, multiply the ∆T50°C output by 1.2.

Terms and Conditions of Trading

A complete copy of the company’s terms and conditions of trading are available on our website www.zehnder.co.uk In addition to the Terms and Conditions, please note the following: n All delivery times quoted are estimates only. Prices quoted include free delivery to the UK mainland for radiators and towel rails. Orders for valves, fans, elements and accessories with a net order value under £100 are subject to a processing charge of £10 + VAT n Returned goods for credit will only be accepted by prior arrangement (confirmed in writing), within 8 weeks of the date of despatch, where the goods are part of our stock range and where the goods are as fit for sale on their return as they were on delivery. If goods have been fitted this is deemed as acceptance of their quality. We cannot accept the return of non-stock goods. n Damaged products are to be reported to us within 3 days of delivery. Zehnder cannot be held responsible for any damage after onward delivery. Faulty products are to be reported to us as soon as possible. If the items have been installed, you are in acceptance of it’s condition and Zehnder reserve the right to refuse credit. n You are responsible for ensuring the suitability, conformity and interoperability of the goods or indicative system design suggestions provided by us with your heating system and your design requirements. It is important that you undertake such verification with an appropriately qualified expert third party n Where a radiator is returned as no longer required and an alternative radiator is not ordered a 25% restocking fee plus a £10 administration fee will be charged (unless the goods were defective when delivered). If a radiator is no longer required but an alternative radiator is ordered, either a restocking fee of £25 or 25% of the value (whichever is the lower) will be charged, but the administration fee will be waived. n We warrant the goods for a period of 5 years for steel radiators, 10 years for stainless steel and aluminium radiators, 2 years for radiator electrical componentry and 3 years for extractor fans, from the date of delivery. The warranty is subject to correct installation to current standards/water treatments and use. n Radiators with steel components (other than stainless steel) must not be installed on a domestic hot water circuit. If a stainless steel or brass product is to be installed on the domestic hot water circuit, a check should be made with the local water authority to ensure that dezincification is not a common occurrence. n Artificially softened water should not be used to fill radiators. For FAQ radiator/water-related information, visit www.fernox.com. n All measurements given in this brochure are nominal dimensions only. n All brochures, catalogues and other promotional materials are to be treated as illustrative only. Their contents form no part of any contract between us and you should not rely on them in entering into any contract with us. Any typographical, clerical or other error or omission in any literature, quotation, price list, or other document issued by us will be subject to correction without liability being incurred by us. Bathroom Zones The diagram below shows a bathroom divided into four clear zones: 0, 1, 2 and outside zones. Please note, the diagram is only a guide and is NOT to scale. Please refer to I.E.E Wiring Regulations (BS 7671:2008) for detailed information. Zone 0: Inside the bath Zone 1: Area above bath / shower tray to a height of 2.25m. Minimum rating of IPX4 should be used unless water spray will be present. In this case, a rating of IPX5 should be used. Zone 2: Area stretching 0.6m from zone 1. Minimum rating of IPX4 should be used here. Outside Zones: No water spray is likely to be used here, therefore, no IP rating is required. IP Rating: “X” denotes level of security against dust particles. Second digit denotes level of “watertightness”. IPX5: Protected against low pressure water jets IPX4: Protected against splashing water 64

Space under bath is Zone 1, if readily accessible

N.B: The above diagram is only a guide and not to scale. Please refer to I.E.E. Wiring Regulations (BS 7671 : 2008).

What is an inhibitor and why should it be used in a central heating system? An inhibitor is a chemical mix that should be added to the central heating system water to prevent corrosion and to prolong the life of the system. When new or additional radiators are being installed, the system should be drained, cleaned and flushed in accordance with BS7593 and a good quality chemical water treatment inhibitor should be added to the heating system. Can steel and aluminium radiators be put on the same system? Yes, as long as an inhibitor for mixed metal systems is used. In reality, most systems are already mixed metal, as many have aluminium heat exchangers in the boiler, plus copper pipes and steel radiators already installed. Why is it important to use dual energy installations correctly? Simultaneous use of the electrical element and the central heating system should be avoided as this will shorten the life of the element and invalidate the warranty. Correct use is as follows: In summer when the central heating is switched off, vent the radiator to ensure there is no air present, then close the flow valve (only) and activate the immersion heater. In winter, de-activate the immersion heater and open the flow valve. What is the difference between outputs listed at ΔT60°C and ΔT50°C? ΔT60°C allows for older boiler systems, whilst ΔT50°C is the new European testing standard for modern boilers, such as condensing boilers, which have lower flow and return temperatures. Therefore, to avoid radiators being incorrectly sized, it is important to know the system’s temperatures and take them into consideration.

January 2019

65


Notes

66

January 2019

67


Š Zehnder (retail) - A Division of Zehnder Group UK Ltd. Modification rights reserved. V12019.1 Zehnder Group UK Ltd Concept House . Watchmoor Point . Camberley . Surrey . GU15 3AD . Registered in England: 2296696 T: +44 (0) 1276 605800 F: +44 (0) 1276 24058 For placing an order . orders@zehnder.co.uk For general enquiries . retailsales@zehnder.co.uk aftersales@zehnder.co.uk quotes@zehnder.co.uk www.zehnder.co.uk


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.