The IP ratings (an abbreviation for International Protection ratings) is a two-numbered representation for protection against solids and water. The rst digit represents the protection rating against certain


solid foreign objects (such as dust) while the second digit is the actual protection against water. Understanding IP rating for lights The IP rating (Ingress Protection) is an internationally recognized method utilized to describe and measure the level of protection of electrical appliances against water and other technical components. It’s always advisable to choose the right IP rating for your exterior lights plus ceiling fans so as to prevent hazardous accidents. For enclosures, the emblematic “waterproof” IP ratings include IP67, IP66 & IP65 enclosures. The table below explains the meaning of each of these ratings and how they’re arrived at.

IP Rating

The actual Protection offered

Description of the offered protection

Test Method

IP65 Enclosures

These ones can protect against any water jets

Water entry is projected by a nozzle (which is 6.3 mm long) against enclosures from all directions and must not have any harmful effect.

Test duration: The test takes about 15 minutesWater volume: It requires about 12.5 liters of water per minutePressure: The test requires a pressure of 30 kPa at a 3m-distance

IP66 Enclosures

This one can offer protection

Water is projected in dominant jets (i.e. a 12.5 mmNozzle)

Test duration: It requires about 3 minutesWater volume: The test


IP67 Enclosures

against water jets

against enclosures from all directions and shouldn’t have any harmful effects.

requires 100 liters of water per minutePressure: The test must be done at a pressure of 100 kPa and at a 3m

These ratings can protect against an Immersion of up to 1 m

It protects entrance of large volume water and when the enclosure in question is immersed in water(but under pre-de ned under prede ned pressure and time conditions)

Test duration is 30 minutes The immersion should be at a depth of more than 1 m measured from the bottom of the device and more than 15 cm measured from the top of the device

IK Rating: What is it? IK ratings denote the European standard EN — the equivalent of IEC 62262 (2002) standards. This represents an international numeric classi cation concerning degrees of protection by enclosures for all electrical appliances against external mechanical forces/impacts. IP rating in electrical appliances The IP Code is an International Protection Marking that interprets the IP code as an Ingress Protection Marking. It also classi es & rates it as the level protection against intrusion, dust, unintentional contact, as well as water. IP ratings brief history


IP ratings were rst developed by the International Electro-technical Commission. They are mostly used in Europe & Asia, but nd some adherents in parts of North America. Since they’re international standards, testing and certi cation is done by the TUV and not UL. Note: IP ratings were developed to address harsh environments and not ultraviolet rays (UV) protection. Thus, engineers should incorporate additional materials that offer UV protection.

IK RATING

INGRESS PROTECTION

IP65 ENCLOSURES

IP RATINGS

IP RATINGS EXPLAINED

IP67 ENCLOSURES

PREVIOUS POST

Architectural Lighting for Buildings NEXT POST

Why Light Output Should Be Measured In Lumens & Not Watts

LEAVE A REPLY Your email address will not be published. Required elds are marked *

Name *

Email *

Website

Comment


You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>

POST COMMENT

Search …

RECENT POSTS An update on the Light Bulb Ban An Introduction to DMX Lighting Control Why Light Output Should Be Measured In Lumens & Not Watts IP Ratings Explained Architectural Lighting for Buildings

RECENT COMMENTS saving on The 2D Compact and 2 Pin 4 Pin technical information saving on How to calculate the LUX level in a Room saving on LED Ceiling Lights: They Will Rede ne Your Living Room saving on The 2D Compact and 2 Pin 4 Pin technical information saving on How to calculate the LUX level in a Room

ARCHIVES July 2018 May 2018 April 2018 March 2018 February 2018


August 2017 July 2017 June 2017 May 2017 February 2017 January 2017 December 2016 June 2016 May 2016 April 2016 March 2016 February 2016 January 2016 November 2015 September 2015 August 2015 July 2015 June 2015 March 2015 October 2014 September 2014 June 2014 April 2014 December 2012 September 2012 July 2012 April 2012 February 2012 January 2012


December 2011 October 2011 September 2011 August 2011 July 2011 May 2011 February 2011 January 2011 October 2010 September 2010 August 2010 July 2010

CATEGORIES Light Bulb General Information Lighting Design Technologies The Environment Uncategorised Uncategorized

META Log in Entries RSS Comments RSS WordPress.org

Proudly powered by WordPress


:: Traditional Lighting

:: Eco Schools

:: The Environment

:: Lighting Design

Desktop Version Copyright © 2018 Saving Light Bulbs. Powered by Towers IT Professional Services Ltd Your IP Address is: 169.54.6.221


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.