Emergency Brochure

Page 1


EMERGENCY LIGHTING 2025

SIGHTPRO EMERGENCY DOWNLIGHT

High output recessed emergency downlight

INTERCHANGEABLE BEZELS White, silver and black bezels

• 3-hour non-maintained emergency fitting

• Including white, silver and black bezels

• Constructed from aluminium alloy & polycarbonate

TECHNICAL DRAWINGS

SPECIFICATION DATA

Product

Product Lumen

Dimmable

SIGHTPRO

Reliable, robust, weatherproof and functional LED EM bulkhead

18M VIEWING DISTANCE

• 5 years warranty on battery based on operating temperature 0 - 45ºC

• Constructed from polycarbonate

• 3 hours emergency maintained and non-maintained fitting

• 4 conduit knockouts

Push fit connector
Switch for self
& manual
(108749)

SPECIFICATION DATA

SIGHTPRO MINI

Reliable, robust, weatherproof and functional LED EM bulkhead

• Constructed from polycarbonate

• 24m viewing distance

• Supplied with ISO 7010 sticker set

220 LUMENS

MAINTAINED & NON MAINTAINED 18M VIEWING DISTANCE

TECHNICAL DRAWINGS

SPECIFICATION DATA

Product Wattage 3W

Product Lumen 220

Lumen/W 73

EM Wattage 1.5W

EM Lumen 130Lm Kelvin 6500K

Dimmable No

Inrush Current at Start Up

IP Rating

SIGHTPRO BOX

Wall mounted emergency light suitable for all applications

25 LUMENS

MAINTAINED & NON MAINTAINED

• Constructed from steel & polycarbonate

• Emergency maintained & non-maintained fitting

• Manual & self-test switchable

Supplied with up, left & right arrows

SPECIFICATION DATA

Product

LED guide fitting with 6 mounting options ADJUSTABLE HEIGHT

SPECIFICATION DATA

Product Wattage 3.5W

Product Lumen 110

Lumen/W 31

EM Wattage 0.4W

EM Lumen 50Lm Kelvin 6500K

Dimmable No

Angle

Driver Type

Inrush Current at Start Up

Product

Surge Protection (KV) 1

Operating Temperature 0 - 45ºC

IP Rating

Battery Specification

Duration 3 hours (180 minutes) Product Weight (Kg) 0.75 Terminal Block 3 way

SIGHT

Adjustable twin spot emergency wall pack

SELF TEST

• Constructed from steel & frosted polycarbonate

• Gloss white finish

• Non-maintained fitting

• Manual & self-test switchable

TECHNICAL DRAWINGS

SPECIFICATION DATA

Product Wattage 2 x 1.25W

EM Wattage 2 x 2W

EM Lumen 600Lm

EM Lumen/W 150 Kelvin 6500K

Dimmable No

Angle

(Hours)

Driver Type

Inrush Current at Start Up 1.5A

Product Voltage 220-240V Hertz 50/60

Surge Protection (KV) 1

Operating Temperature 0 - 45ºC

IP Rating IP65

IK Rating IK08

Battery Specification

Duration 3 hours (180 minutes)

Product Weight (Kg) 0.845

Terminal Block 3-way fast fix

EMERGENCY LED CONVERSION KIT

See product pages and Saxbytrade.com for recommended usage and compatibility

• Self

EMERGENCY CONVERSION

Self-contained emergency non-maintained fitting

• Constructed from steel & frosted polycarbonate

• Gloss white finish

• 230V GU10, Max. 8W

Icons Guide

Each of our products have appropriate icons displayed against them. Our handy icon guide helps to explain what each of our icons mean.

1, 2, 3 or 5 year warranty, refer to T&Cs 5YR WARRANTY

Class 1, earthed product

CLASS 1

CLASS 2

CLASS 3

Class 2, double insulated product

Class 3, super extra low voltage product (driver required)

Suitable for use in 30, 60 or 90 minute fire rated ceilings FIRE RATED 30,60,90MINS

Denotes IP rating IP65 RATED

Operating Modes

MAINTAINED

IK08 RATED

EMERGENCY MAINTAINED

EMERGENCY

EMERGENCY SELF TEST

Meets EN 62262 impact resistance

Emergency Maintained

Emergency Non Maintained

Emergency Maintained Self Test

beam angle

Maintained emergency lights are always on, which doubles up as a building’s primary lighting supply and is linked to a chargeable battery. The light will remain on at all times but when the power is lost from the mains the battery will take over to keep the light visible.

NON MAINTAINED

Non maintained emergency lights are designed to switch on when the building’s main power is lost. The light is linked to a battery and to the building’s lighting circuitry, which makes sure the battery is always charged. These lights remain off whilst the mains powers is working properly and will only turn on when the power is lost.

MAINTAINED SELF TEST

Self testing emergency lighting checks itself automatically to ensure the battery and lamp in each emergency lights is fully operational. If a problem is detected by the self-test the system will display and visual warning and sound an audible warning. The self test feature replaces the manual test carried out annually.

Viewing distance

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.