ARMOR GLASS BROUCHER

Page 1

Clearly, your knight in shining armor


Armor Glass Armor Glass brings the benefits of strength and safety to any application and is an ideal recourse for the building and construction industry. The formidable strength of Armor Glass makes for effective prevention from impact and brute contact.



Armor Glass is a laminated glass, regarded as a safety glass, consisting of two or more panes of glass with one or more layers of polyvinyl butyral (PVB) sandwiched between them and treated. The glass panes can be basic float glass or tempered or heat strengthened panel. If the glass is broken fragments tend to adhere to the PVB interlayer thereby reducing the risk of injury from falling glass and helping to resist further impact or weather damage. PVB membrane has good tenacity performance and when the laminated glass breaks due to violent force, the PVB will absorb large amount of impact energy and disperse it rapidly. Therefore, it hard to break the laminated glass and the shape of the glass may be maintained even if being broken. Furthermore, personnel inside and outside the buildings will not be hurt by the glass fragment.

Safety Application Safety glazing applications, such as doors and sloped overheads, require a minimum .030" (.76 mm) thick PVB interlayer. Clear PVB plies can be added to achieve the minimum .030" (.76 mm) thickness required in safety glazing areas.

Solar Control Application The glass also possesses other unique properties, which make it an excellent product for commercial buildings. For instance, laminated glass provides the greatest reduction of ultraviolet (UV) light transmission of any commercial glass product available. When combined with two layers of float glass, less than one percent of UV light is transmitted. This is important when considering the type of glass product to use in applications where UV protection is essential. However, light and heat can also contribute to the fading of interior furnishings. It is important to consider using laminated glass products, which help to reduce visible light transmission and radiant heat.


Sound Control Application Another important element of laminated glass is acoustical performance in commercial applications. Laminated glass reduces noise transmission due to sound damping characteristics of the PVB interlayer. While glass is inherently a poor acoustical performer, higher performance levels can be achieved by using laminated glass alone or combined with additional glass plies to form a sealed insulating glass unit.

Protective Glazing Applications Security - For many years laminated glass has been used in low-to-medium level security applications.

Windborne Debris - The glass protects building interiors from the winds and rain associated with hurricanes. Armor glass is a durable, high-performance glazing that provides glass retention in the opening if the glass is broken due to the impact of flying debris.

Bomb Blasts - Armor glass offers protection when a building is exposed to the threat of explosives. Tests have shown that when windows glazed with laminated glass are subjected to a blast impulse, broken glass fragments tend to adhere to the plastic interlayer rather than spraying building occupants with harmful glass shards or other debris.


Ideal Applications of Armor Glass Building Facades Commercial and Residential buildings can strongly benefit from the advantages that Armor Glass has to offer. Durability and protection offer the ideal mix of quality for the safety conscious developer.

Windows Windows that employ Armor Glass are of the highest quality and have a strong structure and long life. The strength of the glass tolerates regular challenges of impact by restraining them considerably.

Airports High impact on glass due to extensive passenger circulation can be controlled with Armor Glass' properties. Suitable applications can be seen in waiting areas, airline counter separators and passenger waiting lounges.

Hotels Where guests need maximum protection during their stay, Armor Glass can provide a bounty of benefits ranging from protection and safety to offering clear hotel interior and exterior views and energy saving properties, thereby reducing costs of air conditioning.

Railings Armor Glass architectural glass can be configured for use on railings and balustrades, providing a clean contemporary design that can be used in offices, retail and commercial applications. It offers an attractive alternative to opaque material counterparts while still meeting safety requirements.


Staircases Owing to the toughness of Armor Glass, innovative flooring concepts and walkways can be designed, providing immense opportunities to the architect to create something beyond what is offered by conventional flooring materials.

Canopies Glass can easily be configured for overhead roofing offering day lighting and protection from impact and harsh environments. It can also be customized for additional glazing properties like tinting, etc.


Construction

Multilayer

Thickness Range For Each Glass Lite

mm

3 to 9

Overall Laminated Thickness Range

mm

4 to 80

Max. Weight Per Laminate

kg

Material Types

Interlayer Interlayer Thickness

1000 Glass-Figured/Patterned , Clear, Extra Clear, Body Tinted, Solar Reflective, Pyrolytic or Soft Coated Low E and Solar Low E (annealed Heat Strengthened or Fully Toughened), Polycarbonate

mm

PVB, PET, PU - Clear, Tinted, Reflective, Translucent, Design, Cast-In Place Resin-Clear, Tinted or Translucent

mm

0.38 to 3.00

Glass shapes

Any shape with linear or curved edges

Max. Size Of Glass

mm

4500 x 2600

Max. Size Of Glass

mm

400 x 250

Sezliaise™ Contact our Sales Team for further information. To fix a consultation or obtain additional literature contact us on 91-22-28665100 or send an email to info@sezalglass.com

FIELD SALES REPRESENTATIVES We're here to help with design assistance, budget costing, return on investment costing, spec writing and review as well as act as a liaison between architects and glazing contractors. We also work closely with the glazing contractor to offer assistance with initial costs, final pricing negotiations, product information and job site inspections. Just ask.


Glossary Color Rendering Index (CRI) The ability of transmitted daylight through the glazing to portray a variety of colors compared to those seen under daylight without the glazing. Scale is 1 - 100. For instance, a low CRI causes colors to appear washed out, while a high CRI causes colors to appear vibrant and natural. In commercial glass, CRI indicates the effect the specific glass configuration has on the appearance of objects viewed through the glass. Heat gain is heat added to a building interior by radiation, convection or conduction.

Heat Transfer Methods Heat transfer occurs through convection, conduction or radiation (also referred to as "emission"). Convection results from the movement of air due to temperature differences. For instance, warm air moves in an upward direction and, conversely, cool air moves in a downward direction. Conduction results when energy moves from one object to another. Radiation, or emission, occurs when heat (energy) can move through space to an object and then is transmitted, reflected or absorbed.

Light to Solar Gain Ratio of the visible light transmittance to the Solar Heat Gain Coefficient. A higher LSG ratio means sunlight entering the room is more efficient for daylighting, especially for summer conditions where more light is desired with less solar gain. This ratio is the measurement used to determine whether the glazing is "spectrally selective."

Low-E Coatings Relatively neutral in appearance, low-E coatings reduce heat gain or loss by reflecting longwave infrared energy (heat) and, therefore decrease the U-Value and improve energy efficiency. Current sputter-coated low-E coatings are multilayered, complex designs engineered to provide high visible light transmission, low visible light reflection and reduce heat transfer.


Relative Heat Gain (RHG) The total heat gain through glass for a specific set of conditions. This value considers indoor/outdoor air temperature differences and the effect of solar radiation.

R-Value A measure of the resistance of the glazing to heat flow. It is determined by dividing the UValue into 1. A higher R-Value indicates better insulating properties of the glazing. R-Value is not typically used as a measurement for glazing products and is referenced here to help understand U-Value.

Shading Coefficient (SC) An alternative measure of the heats gain through glass from solar radiation. Specifically, the shading coefficient is the ratio between the solar heat gain for a particular type of glass and that of double strength clear glass. A lower shading coefficient indicates lower solar heat gain.

Solar Energy Radiant energy from the sun having a wavelength range of 300 to 4000 nm, which includes UV (300 to 380 nm), visible light (380 to780 nm) and near infrared energy (780 to 4000 nm). % Reflectance Out - percentage of incident solar energy directly reflected from the glass back outdoors. % Absorptance - percentage of incident solar energy absorbed into the glass. % Transmittance - percentage of incident solar energy directly transmitted through the glass. The sum of percent reflectance out + absorptance out + transmittance = 100%. An additional consideration is emission, or emissivity. This refers to the reradiation of absorbed energy that can be emitted toward both the exterior and interior of the building. Emissivity is controlled through the use of low-emissivity, or low-E coatings.


Solar Heat Gain Coefficient (SHGC) The percent of solar energy incident on the glass that is transferred indoors, both directly and indirectly through the glass. The direct gain portion equals the solar energy transmittance, while the indirect is the fraction of solar incident on the glass that is absorbed and re-radiatedor convected indoors.

Solar/Reflective Coatings Typically, highly reflective coatings that reduce solar heat gain through reflection and absorption. Though very effective at reducing heat gain, visible light transmittance is generally low and U-Values are not as energy efficient as low-E coatings.

Transmittance Percent Percentage of incident ultraviolet energy that is directly transmitted through the glass. Long-termexposure to UV light may result in fabric and pigment fading, plastic deterioration and changes to the appearance of many types of wood.

UV Ultraviolet radiant energy from the sun having a wavelength range of 300 to 380 nm with airmass of 1.5.

U-Value (U-Factor) A measure of the heat gain or loss through glass due to the difference between indoor & outdoor air temperatures. It is also referred to as the overall coefficient of heat transfer. A lower U-Value indicates better insulating properties. The units are Btu/(hr)(ft2)(째F).


WATER WIND SKY

Indian Green Building Council

Member IGBC

EARTH FIRE

DIN EN ISO 9001:2008

SEZAL GLASS LTD. 201/ 202, Abilasha, 2nd Floor, S.V. Road, Kandivali (W), Mumbai - 400 067, INDIA. Tel: +91-22-2863 3383 / 84 / 85 / 86 | Fax: +91-22-2863 3389 / 90 Email: customercare@sezalglass.com | www.sezalglass.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.